ProFlow PF-BTA, PF-SOF1, PF-SOF1-ALT, PF-SOF1-PRL Technical Manual
Advertisement
Advertisement
© 2017 erie water treatment
Technical Manual
WATER SOFTENER
Models: PF-SOF1-SIM
PF-SOF1-ALT
PF-SOF1-PRL
PF-SOF1,5-SIM
PF-SOF1,5-ALT
PF-SOF1,5-PRL
PF-BTA
TM-EN-PF-SOF-Rev2017.01
TABLE OF CONTENT & INSTALLATION RECORD
Table of content & Installation record ..................................................................................... Page 2
Warning & Safety instructions ................................................................................................. Page 3
Operating conditions & Requirements .................................................................................... Page 4
Assembly .................................................................................................................................. Page 5
Installation ............................................................................................................................... Page 7
Commissioning ......................................................................................................................... Page 9
Electronic control panel ........................................................................................................... Page 10
Maintenance ............................................................................................................................ Page 16
Troubleshooting ....................................................................................................................... Page 18
Electrical wiring diagrams ........................................................................................................ Page 20
Default configuration parameter settings - PF-SOF1 ............................................................... Page 21
Default configuration parameter settings - PF-SOF1,5 ............................................................ Page 22
Composition overview ............................................................................................................. Page 23
Exploded view - PF-SOF1-SIM .................................................................................................. Page 24
Exploded view - PF-SOF1-ALT & PF-SOF1-PRL ......................................................................... Page 26
Exploded view - PF-SOF1 - Timer assembly ............................................................................. Page 28
Exploded view - PF-SOF1 - Valve body ..................................................................................... Page 30
Exploded view - PF-SOF1,5-SIM ............................................................................................... Page 32
Exploded view - PF-SOF1,5-ALT & PF-SOF1,5-PRL ................................................................... Page 34
Exploded view - PF-SOF1,5 - Timer assembly .......................................................................... Page 36
Exploded view - PF-SOF1,5 - Valve body .................................................................................. Page 38
Exploded view - PF-SOF1,5 - Piston assembly.......................................................................... Page 40
Exploded view - PF-BTA-Simplex .............................................................................................. Page 42
Exploded view - PF-BTA-Duplex ............................................................................................... Page 43
Technical data - PF-SOF1 .......................................................................................................... Page 44
Technical data - PF-SOF1,5 ....................................................................................................... Page 46
Technical data - PF-BTA ............................................................................................................ Page 48
Page 2
WARNING & SAFETY INSTRUCTIONS
Before you begin the installation of the appliance, we advise you read and carefully follow the instructions contained in this manual. It contains important information about safety, installation, use and maintenance of the product. The actual system that you have received, may differ from the pictures/illustrations/descriptions in these Instructions.
Failure to follow the instructions could cause personal injury or damage to the appliance or property. Only when installed, commissioned and serviced correctly, the appliance will offer you many years of trouble-free operation.
The appliance is intended to 'soften' the water, meaning it will remove hardness minerals; it will not necessarily remove other contaminants present in the water. The appliance will not purify polluted water or make it safe to drink!
Installation of the appliance should only be undertaken by a competent person, aware of the local codes in force. All plumbing and electrical connections must be done in accordance with local codes.
Before setting up the appliance, make sure to check it for any externally visible damage; do not install or use when damaged.
Use a hand truck to transport the appliance. To prevent accident or injury, do not hoist the appliance over your shoulder. Do not lay the appliance on its side.
Keep these Instructions in a safe place and ensure that new users are familiar with the content.
The appliance is designed and manufactured in accordance with current safety requirements and regulations. Incorrect repairs can result in unforeseen danger for the user, for which the manufacturer cannot be held responsible. Therefore repairs should only be undertaken by a competent technician, familiar and trained for this product.
In respect of the environment, this appliance should be disposed of in accordance with Waste Electrical and Electronic Equipment requirements. Refer to national/local laws and codes for correct recycling of this appliance.
Page 3
OPERATING CONDITIONS & REQUIREMENTS
OPERATING PRESSURE MIN-MAX: 1,4-8,0 bar / 20-116 psi
this appliance is configured to perform optimally at an operating pressure of 3 bar (45 psi) ±½ bar (7 psi); in case of a lower or higher operating pressure the performance may be affected negatively!
check water pressure regularly; it may fluctuate severely depending on the time of day, the day of the week or even the season of the year.
take into account that night time water pressure may be considerably higher than day time water pressure.
install a pressure reducer ahead of the appliance if necessary.
install a pressure booster, if it is likely that water pressure may drop below the minimum.
OPERATING TEMPERATURE MIN-MAX: 2-48 °C / 35-120 °F
do not install the appliance in an environment where high ambient temperatures (e.g. unvented boiler house) or freezing temperatures can occur.
the appliance cannot be exposed to outdoor elements, such as direct sunlight or atmospheric precipitation.
do not install the appliance too close to a water heater; keep at least 3 m (10 ft) of piping between the outlet of the appliance and the inlet of the water heater; water heaters can sometimes transmit heat back down the cold pipe into the appliance; always install a check valve at the outlet of the appliance.
ELECTRICAL CONNECTION:
this appliance only works on 24 VAC; always use it in combination with the supplied transformer.
in case of damage to the power supply cable of the transformer, immediately disconnect the transformer from the power outlet and replace the transformer.
make sure to plug the transformer into a power outlet, which is installed in a dry location, with the proper rating and overcurrent protection.
Page 4
ASSEMBLY
CONTENT CHECK
Actual parts that you have received, may differ from the pictures/illustrations in these Instructions!
For ease of transportation and installation, the softening resin is NOT loaded in the pressure tank, but delivered in separate bags of 25 ltr; it must be loaded on-site, after positioning of the pressure tank.
Check the content of the system, using the Composition
Overview in these Instructions. Identify and lay-out the different components to facilitate the assembly.
SIMPLEX
(PF-SOF1-SIM & PF-SOF1,5-SIM)
A Simplex system consists of 1 single softening module
(pressure tank, resin, control valve and accessories).
During normal operation, the Simplex system delivers softened water.
As soon as it initiates a regeneration, it automatically goes into hard water bypass, guaranteeing uninterrupted supply of untreated water
It is possible to upgrade a Simplex system to a Duplex Parallel system, by adding a second Simplex system.
DUPLEX ALTERNATING
(PF-SOF1-ALT & PF-SOF1,5-ALT)
A Duplex ALTERNATING system consists of 2 Simplex systems, that:
are hydraulically installed in parallel ;
are electronically interconnected by means of an
InterConnect cable;
have a Normally Closed solenoid operated diaphragm valve (so called Service Valve) in the outlet of each
Simplex system; this Service Valve is controlled by the electronic timer of the Simplex system and is activated during the service cycle to open the outlet of the respective Simplex system;
share 1 brine tank, that contains 2 brine valves.
During normal operation, only 1 of the 2 Simplex systems is in service, while the other one is regenerating or ‘in standby’ !
As soon as the first Simplex system initiates a regeneration, the second system goes into service, guaranteeing uninterrupted supply of treated water. In case of a power failure, both Service Valves will be deactivated, meaning the outlet of both Simplex systems will be closed off, cutting off the water supply (potentially hard water!) to the application.
DUPLEX PARALLEL
(PF-SOF1-PRL & PF-SOF1,5-PRL)
A Duplex PARALLEL system consists of 2 Simplex systems, that:
are hydraulically installed in parallel ;
are electronically interconnected by means of an
InterConnect cable;
have a Normally Open solenoid operated diaphragm valve
(so called Service Valve) in the outlet of each Simplex system; this Service Valve is controlled by the electronic
Page 5 timer of the Simplex system and is activated during the entire duration of the regeneration, to close-off the control valve's standard 'hard water bypass during regeneration';
share 1 brine tank, that contains 2 brine valves.
During normal operation, both Simplex systems are in service, doubling the service flow rate!
When one of the
Simplex systems initiates a regeneration, it immediately communicates it's status to the other Simplex system via the
InterConnect cable, to make sure the other Simplex system remains in service, guaranteeing uninterrupted supply of treated water. In case of a power failure, both Service Valves will be deactivated, meaning the outlet of both Simplex systems will be open, guaranteeing uninterrupted supply of water.
For correct assembly, repeat the different assembly steps, until both Simplex systems are assembled and positioned correctly.
For large installations, with an important need for treated water, 2 or more Duplex systems can easily be installed in parallel hydraulically, to double/triple/... the flow rate and softening capacity.
RESIN LOADING
1.
Move the pressure tank to the correct installation location; position it on a flat and level surface. Make sure to leave enough space for ease of service.
2.
Position the riser assembly upright and centred in the pressure tank; plug the top of the riser tube with a piece of tape or clean rag, to prevent resin from entering the tube.
3.
Add water to the pressure tank to a height of ±30 cm from the bottom; this water will protect the bottom of the pressure tank and the bottom distributor, during filling of the pressure tank.
4.
Place a funnel on the pressure tank opening and fill the pressure tank with resin; make sure the riser assembly remains centered in the pressure tank.
5.
Rinse the pressure tank opening to remove any resin beads from the threaded section.
6.
Unplug the top of the riser tube.
CONTROL VALVE only for PF-SOF1
1.
Make sure the O-ring in the riser insert and the tank Oring (around the threaded section of the control valve) are in the correct position.
2.
Screw the top distributor onto the control valve.
3.
Lubricate the threaded section of the pressure tank, the top of the riser tube and the tank O-ring of the control valve; use a silicon-based lubricant.
4.
Lower the control valve straight down onto the riser tube, until the riser tube is correctly inserted in the riser insert; then push it down firmly and screw it onto the pressure tank.
ASSEMBLY only for PF-SOF1,5
Picture 1
1.
On the brass valve seat:
make sure the O-ring in the riser insert is in the correct position;
install the top distributor and fix it by means of the 2 stainless steel screws;
install the tank O-ring in the groove on the flange around the threaded section.
2.
Lubricate the threaded section of the pressure tank, the top of the riser tube and the tank O-ring of the valve seat; use a silicon-based lubricant.
3.
Lower the valve seat straight down onto the riser tube, until the riser tube is correctly inserted in the riser insert inside the valve seat; then push it down firmly and screw it onto the pressure tank.
4.
Install the valve seat O-ring in the groove on the valve seat.
5.
Install the control valve onto the valve seat; mind the alignment pin!
6.
Bolt the control valve to the valve seat by means of the 4 stainless steel bolts; tighten firmly.
BRINE TANK ASSEMBLY (PF-BTA) (optional)
Picture 2&3
1.
Move the brine tank to the correct installation location; position it on a flat and level surface. Make sure to leave enough space for ease of service.
2.
Insert the polytube into the brine line connection on the control valve ( ); make sure to push the polytube in all the way; tighten the nut.
3.
Remove the lid from the brine tank.
4.
Remove the lid from the brine well.
5.
Make sure the correct elbow connection is installed on the brine valve (⅜” for PF SOF1 or ½” for PF-SOF1,5); replace if necessary.
6.
Run the polytube from the control valve through the hole in the sidewall of the brine tank, to the inside of the brine tank.
7.
Only for PF-SOF1,5 : insert the reinforcement tube in the end of the ½” polytube.
8.
Insert the polytube into the elbow connection on the brine valve; make sure to push the polytube in all the way.
9.
Only for PF-SOF1,5 : tighten the nut.
10.
Install the lid on the brine well.
11.
Add water to the brine tank to a height of ±10 cm from the bottom.
12.
Add salt to the brine tank.
13.
Install the lid on the brine tank.
Page 6
INSTALLATION
INLET & OUTLET
In case of high concentration of impurities in the inlet water, we recommend the installation of a sediment filter, ahead of the appliance.
We strongly recommend the use of flexible hoses to connect the appliance to the water distribution system; use hoses with a large diameter in order to limit the pressure loss.
We strongly recommend the installation of a bypass system (not included with this product!) to isolate the appliance from the water distribution system in case of repairs. It allows to turn off the water to the appliance, while maintaining full-flow (untreated) water supply to the user. only for PF-SOF1-SIM:
SIMPLEX with factory bypass (optional)
Picture 4
= mains water supply (untreated water)
= inlet of control valve (untreated water)
= outlet of control valve (treated water)
= application (treated water)
1.
Screw the factory bypass onto the in/out ports on the control valve ( & ); make sure to install the gasket seals. Tighten the nuts firmly by hand.
2.
Screw the connection kit with nuts onto the factory bypass ( & ); make sure to install the gasket seals.
Tighten the nuts firmly by hand.
3.
Connect the mains water supply to the adaptor on the inlet port of the factory bypass ( ).
4.
Connect the application to the adaptor on the outlet port of the factory bypass ( ). only for PF-SOF1-SIM:
SIMPLEX with 3-valve connection kit (not included)
Picture 5
= inlet of control valve (untreated water)
= outlet of control valve (treated water)
1.
Install the 3-valve connection kit.
2.
Screw the connection kit with nuts onto the in/out ports on the control valve ( & ); make sure to install the gasket seals. Tighten the nuts firmly by hand.
3.
Connect the IN valve of the 3-valve connection kit to the adaptor on the in port of the control valve ( ).
4.
Connect the OUT valve of the 3-valve connection kit to the adaptor on the out port of the control valve ( ).
5.
Connect the mains water supply to the inlet of the 3-valve connection kit.
6.
Connect the application to the outlet of the 3-valve connection kit. only for PF-SOF1-ALT and PF-SOF1-PRL:
DUPLEX with multiple valve connection kit (not incl.)
Picture 6
= inlet of control valve (untreated water)
= outlet of control valve (treated water)
= Service Valve
1.
Install the multiple valve connection kit.
2.
Screw the connection kit with nuts onto the in/out ports on the control valve ( & ); make sure to install the gasket seals. Tighten the nuts firmly by hand.
3.
Screw the Service Valve ( ) onto the adaptor at the out port of the control valve ( ); make sure to respect the flow direction (see indication arrow on the bottom of the
Service Valve); use an appropriate sealant.
4.
Connect the IN valve of the multiple valve connection kit to the adaptor on the in port of the control valve ( ).
5.
Connect the OUT valve of the multiple valve connection kit to the outlet of the Service Valve ( ).
6.
Repeat steps 2-5 for both Simplex systems.
7.
Connect the mains water supply to the inlet of the multiple valve connection kit.
8.
Connect the application to the outlet of the multiple valve connection kit. only for PF-SOF1,5-SIM:
SIMPLEX with 3-valve connection kit (not incl.)
Picture 7
= inlet of control valve (untreated water)
= outlet of control valve (treated water)
= PVC elbow
= inlet of flow meter
= outlet of flow meter
1.
Install the 3-valve connection kit.
2.
Insert the adaptors in the in/out ports on the control valve
( & ); make sure not to damage the O-rings. Install the nuts and tighten them firmly by hand.
3.
Screw the PVC elbow ( ) onto the adaptor at the out port of the control valve ( ); use an appropriate sealant.
4.
Insert the adaptors in the in/out ports on the flow meter
( & ); make sure not to damage the O-rings. Install the nuts and tighten them firmly by hand.
5.
Screw the flow meter ( ) into the PVC elbow ( ); make sure to respect the flow direction (see indication arrow); use an appropriate sealant.
6.
Connect the flow meter cable from the control valve to the flow meter; secure it by means of the screw.
7.
Connect the IN valve of the 3-valve connection kit to the adaptor on the in port of the control valve ( ).
8.
Connect the OUT valve of the 3-valve connection kit to the adaptor on the out port of the flow meter ( ).
9.
Connect the mains water supply to the inlet of the 3-valve connection kit.
10.
Connect the application to the outlet of the 3-valve connection kit. only for PF-SOF1,5-ALT and PF-SOF1,5-PRL:
DUPLEX with multiple valve connection kit (not incl.)
Picture 8
= inlet of control valve (untreated water)
= outlet of control valve (treated water)
= PVC elbow
= inlet of flow meter
= outlet of flow meter
= Service Valve
1.
Install the multiple valve connection kit.
2.
Insert the adaptors in the in/out ports on the control valve
( & ); make sure not to damage the O-rings. Install the nuts and tighten them firmly by hand.
Page 7
INSTALLATION
3.
Screw the PVC elbow ( ) onto the adaptor at the out port of the control valve ( ); use an appropriate sealant.
4.
Insert the adaptors in the in/out ports on the flow meter
( & ); make sure not to damage the O-rings. Install the nuts and tighten them firmly by hand.
5.
Screw the flow meter ( ) into the PVC elbow ( ); make sure to respect the flow direction (see indication arrow); use an appropriate sealant.
6.
Connect the flow meter cable from the control valve to the flow meter; secure it by means of the screw.
7.
Screw the Service Valve ( ) onto the adaptor on the out port of the flow meter ( ); make sure to respect the flow direction (see indication arrow on the bottom of the
Service Valve); use an appropriate sealant.
8.
Connect the IN valve of the multiple valve connection kit to the adaptor on the in port of the control valve ( ).
9.
Connect the OUT valve of the multiple valve connection kit to the outlet of the Service Valve ( ).
10.
Repeat steps 2-9 for both Simplex systems.
11.
Connect the mains water supply to the inlet of the multiple valve connection kit.
12.
Connect the application to the outlet of the multiple valve connection kit.
3.
For Duplex : repeat steps 1-2 for both Simplex systems.
PF-BTA: brine tank assembly (optional)
1.
Install the air gap to the sewerage system; it fits over a
32 mm pipe or inside a 40 mm pipe adaptor. Ensure a permanent and watertight connection.
2.
Connect a 13 mm hose to the overflow elbow on the brine tank; secure it by means of a clamp.
3.
Run the drain hose to the air gap and connect it to one of the hose barbs; secure it by means of a clamp. This drain line does NOT operate under pressure, so it may NOT be installed higher than the brine tank.
Picture 11
SERVICE VALVES
(only for Duplex)
1.
Plug the DIN plug on the connection cable of the Service
Valve into the DIN socket at the back of the electronic timer head of the respective control valve ( ).
DRAIN
We recommend the use of a stand pipe with P-trap.
To prevent backflow from the sewerage system into the appliance, always install and use an air gap (drain adaptor with air gap included with PF-SOF1), to connect the drain hoses to the sewerage system.
Always use separate drain hoses for the control valve(s)
(discharge of rinse water) and the brine tank overflow.
Lay-out the drain hoses in such a way that pressure loss is minimized; avoid kinks and unnecessary elevations.
Make sure that the sewerage system is suitable for the rinse water flow rate of the appliance. only for PF-SOF1
Picture 9
1.
Install the drain adaptor to the sewerage system; it fits over a 32 mm pipe or inside a 40 mm pipe adaptor. Ensure a permanent and watertight connection.
2.
Connect a 13 mm hose to the drain connection of the control valve ( ); secure it by means of a clamp.
3.
Run the drain hose to the drain adaptor and connect it to one of the hose barbs; secure it by means of a clamp. This drain line operates under pressure, so it may be installed higher than the appliance.
4.
For Duplex : repeat steps 1-3 for both Simplex systems.
only for PF-SOF1,5
Picture 10
1.
Connect a pipe to the 1” BSP Male drain connection of the control valve ( ); use an appropriate sealant.
2.
Run the pipe to the sewerage system and connect it, ensuring sufficient air gap between the end of the pipe and the sewerage system. This drain line operates under pressure, so it may be installed higher than the appliance.
Page 8
COMMISSIONING
ELECTRICAL
1.
Connect the appliances power cord to the transformers output.
2.
Plug the transformer into an electrical outlet.
PRESSURIZING
1.
Put the bypass system in 'bypass' position.
2.
Make sure the electronic controller(s) of the appliance is
(are) in service mode.
3.
Open the mains water supply.
4.
Open a cold treated water faucet nearby the appliance and let the water run for a few minutes until all air is purged and all foreign material that may have resulted from the installation is washed out; close the tap.
5.
Gently pressurize the appliance, by putting it into service:
close the 'BYPASS' valve;
open the 'OUT' valve;
slowly open the 'IN' valve.
6.
After 2-3 minutes, open a cold treated water faucet nearby the appliance and let the water run for a few minutes until all air is purged from the installation and the resin bed is rinsed (it is normal for the rinse water to show some discoloration!); close the tap.
7.
Check the appliance and all hydraulic connections for leaks.
8.
For Duplex : repeat steps 5-7 for both Simplex systems.
ELECTRONIC CONTROL PANEL
1.
Program the electronic controller.
2.
For Duplex : repeat step 1 for both Simplex systems.
ADJUSTMENT RESIDUAL HARDNESS
(only for PF-SOF1)
In practice the residual hardness is influenced by the inlet pressure, flow rate and hardness of the incoming untreated water. When adjusting the residual hardness, make sure these conditions are similar to the actual operating conditions.
ON CONTROL VALVE
Picture 12.a
1.
Adjust the residual hardness of the water that leaves the softener, by means of the adjusting screw, incorporated at the right side of the control valve:
to raise the residual hardness: turn the screw counter clockwise;
to reduce the residual hardness: turn the screw clockwise.
2.
Measure the residual water hardness with a water hardness test kit; readjust if necessary.
WITH FACTORY BYPASS (optional)
Picture 12.b
1.
Adjust the residual hardness of the water that leaves the softener, by means of the adjusting screw, incorporated in the 'outlet' valve of the factory bypass:
to raise the residual hardness: turn the screw counter clockwise.
to reduce the residual hardness: turn the screw clockwise.
2.
Measure the residual water hardness with a water hardness test kit; readjust if necessary.
INITIATE A REGENERATION
1.
Manually initiate a regeneration, by pressing the scroll
button; the display will show:
Regen in 10 sec
2.
Leave the appliance in this position; the count-down timer will count down to 0 sec and start a regeneration; to save time you may skip, or terminate prematurely, the second cycle of the regeneration by pressing the scroll button once, as soon as the display indicates that the system is in the second regeneration position.
3.
For Duplex : repeat steps 1-2 for both Simplex systems.
INTERCONNECT CABLE
(only for Duplex)
Picture 13
1.
Connect the control valves to each other by means of the
InterConnect cable; simply plug the DIN plugs on the
InterConnect cable in the DIN sockets at the back of the electronic timer of each control valve ( ).
INITIATE ALTERNATING MODE
(only for Duplex Alternating)
1.
On one of the 2 control valves, manually initiate a regeneration, by pressing the scroll button; the display will show:
Regen in 10 sec
2.
Leave the appliance in this position; the count-down timer will count down to 0 sec and start a regeneration.
3.
Press the scroll button repeatedly, to advance the control valve through the regeneration cycles and put it in Standby mode, until the display shows:
Stdby 1000 L -
Page 9
ELECTRONIC CONTROL PANEL
Picture 14 symbol
button
SCROLL
UP
DOWN function to advance to the next parameter to increase the value of the parameter to decrease the value of the parameter
POWER-UP
After power-up the display will show the installed software version for a period of 5 seconds.
POWER FAILURE
In the event of a power failure, the program will remain stored in the NOVRAM® during an undefined period, while an incorporated SuperCap will maintain the correct time of day during a period of several hours; consequently, in case of prolonged power failure, the time of day might not be maintained; if this happens, the time of day will be reset to
8:00 when the power supply is re-established, while the indication will flash , indicating that the time of day needs to be set.
When the power failure occurs during the execution of an automatic regeneration, the control valve will remain in its last position; when the power supply is re-established, the control valve will return to the service position, stay there for
60 sec. and restart a complete regeneration from the beginning.
Duplex Alternating : the systems status (Service or
Standby) and the remaining capacity:
Srvc 1000L -
Stdby 1000L -
REGENERATION MODE
In regeneration mode the display shows:
Simplex, Duplex Parallel : the total remaining regeneration time and remaining cycle time:
Rgn:123 CycY:456
Duplex Alternating : the total remaining regeneration time and remaining cycle time:
Rgn:123 CycY:456
When the regeneration is finished, the system remains in
Standby, until the other system starts a regeneration:
Stdby 1000L -
The control valve can be reset to service mode at any time by pressing the scroll button, as such manually advancing it through the regeneration cycles.
CHECKING THE FLOW METER
In case of water usage, the remaining capacity counter in the service display will count back. This way the correct functioning of the water meter can be verified.
TIMER FAILURE
In the event of a timer failure, the display will show the message:
Service Required
If powering off/on the appliance doesn’t solve this problem, professional service is required.
MAINTENANCE REMINDER
Once the maintenance interval is reached, the display will intermittently show the message:
Maintenance Now
While the appliance will continue to operate normally, it is recommended to have preventive maintenance performed by a professional.
SERVICE MODE
In service mode the display shows:
Simplex, Duplex Parallel : the time of day and the remaining capacity:
8:01 1000L -
MANUAL REGENERATION
It is possible to manually initiate an immediate regeneration or a delayed regeneration (at the preprogrammed time of regeneration).
1.
Press the scroll button; the display will show:
Regen in 10 sec
If the control panel is left in this position, the countdown timer will countdown to 0 sec and start an immediate regeneration .
To cancel this mode, press the scroll button before the countdown timer has reached 0 sec; the display will show:
Regen @ 2:00
If the control panel is left in this position, a delayed regeneration will be started at the indicated preprogrammed time of regeneration .
To cancel this mode, press the scroll button; the control panel will return to the service mode.
Page 10
ELECTRONIC CONTROL PANEL
HOLIDAY MODE
It is possible to put the appliance in holiday mode; this will prevent automatic regeneration from taking place, yet will ensure the appliance is automatically regenerated at the end of the holiday cycle.
1.
Press the scroll button repeatedly until the display shows:
Holiday: OFF
Press the up or down button to activate the holiday mode by setting the number of full days away from home , or deactivate the holiday mode (OFF).
Once the control panel is back in service mode, the display will show:
8:01 Holiday
The holiday mode is automatically cancelled when a regeneration is manually initiated!
PROGRAMMING INSTRUCTIONS -
BASIC SETTINGS
Before entering the programming mode, make sure that the appliance is in the service mode.
In case no button is pressed in a period of 5 min, the control panel will automatically return to the service mode; any changes made will NOT be saved!
1.
Press the scroll button and hold it for 2 sec until the display shows:
Language: English
Press the up or down button to set the language .
2.
Press the scroll button again; the display will show
(does not apply to Duplex Alternating!) :
Set time: 8:01
Press the up or down button to set the time of day .
3.
Press the scroll button again; the display will show:
HardUnit: °f
Press the up or down button to set the unit of measure for water hardness . Make sure it is identical to the unit of measure of the water hardness test kit or water analysis report that is used to determine the hardness of the incoming untreated water!
4.
Press the scroll button again; the display will show:
Set Hardn: XX °f
Press the up or down button to set the hardness of the incoming untreated water .
5.
Press the scroll button again; the display will show:
Exit
Press the up or down button to save the settings into the NOVRAM® and exit the programming mode.
Page 11
ELECTRONIC CONTROL PANEL
PROGRAMMING INSTRUCTIONS -
CONFIGURATION PARAMETERS
Before entering the programming mode, make sure that the appliance is in the service mode.
All configuration parameters on this appliance have been pre-programmed in the factory, to offer optimal performance in a wide range of applications and situations.
Nevertheless it may be necessary or desirable to change any of these parameters, to further optimize the appliances performance or to adapt it to the specific requirements of the installation. See table at the end of this manual for default configuration parameter settings.
In case no button is pressed in a period of 5 min, the control panel will automatically return to the service mode; any changes made will NOT be saved! only for PF-SOF1-SIM & PF-SOF1,5-SIM
1.
Press the scroll button and hold it for 6 sec until the display shows:
System Check
2.
Within 10 sec, press the up button; the display will show:
Units: Metric
Press the up or down button to set the units of measure (Metric or US) .
3.
Press the scroll button again; the display will show:
MaintInt: 24 mths
Press the up or down button to activate the maintenance reminder function by setting the maintenance interval, or deactivate the maintenance reminder function .
4.
Press the scroll button again; the display will show:
ExCap: 5.5
°f M3/L
Press the up or down button to set the exchange capacity per litre of resin .
5.
Press the scroll button again; the display will show:
Age corr.: 2.0
%
Press the up or down button to set the age correction factor (%/year) to compensate for capacity loss of the resin due to aging.
6.
Press the scroll button again; the display will show:
Resin: XXX liters
Press the up or down button to set the volume of resin .
7.
Press the scroll button again; the display will show:
Override: 7 days
Press the up or down button to set the number of days between regenerations .
8.
Press the scroll button again; the display will show:
Cycle 1: XX min
Press the up or down button to set the length of the regeneration cycle .
Press the scroll button again to advance to the next regeneration cycle.
Cycle 1 Backwash
Cycle 2 Brine draw/slow rinse
Cycle 3 Fast rinse/brine tank refill (PF-SOF1)
Fast rinse (PF-SOF1,5)
Cycle 4 Brine tank refill (PF-SOF1,5)
9.
Press the scroll button again; the display will show:
Regen:Dlyd/Immd
2:00
Press the up or down button to set the regeneration mode :
Dlyd/Immd : when the remaining capacity equals the reserve capacity, a delayed regeneration at the programmed time of regeneration is started; however when the remaining capacity equals 0 before the programmed time of regeneration is reached, an immediate regeneration is started.
Immediate : when the remaining capacity equals
0, an immediate regeneration is started.
Note: Delayed manual regeneration is not available when this regeneration mode is selected.
Delayed : when the remaining capacity equals the reserve capacity, a delayed regeneration at the programmed time of regeneration is started.
10.
Press the scroll button again; the display will show
(only when the regeneration mode is set to ‘Delayed’ or
‘Dlyd/Immd’) :
Regen @ 2:00
Press the up or down button to set the time of regeneration .
11.
Press the scroll button again; the display will show
(only when the regeneration mode is set to ‘Dlyd’ or
‘Dlyd/Immd’) :
Rsrv Variable
Press the up or down button to set the reserve capacity :
Variable : the reserve capacity is calculated automatically, based on the registered daily water usage.
Fxd : press the scroll button again and press the up or down button to set the reserve capacity to a fixed amount .
Page 12
ELECTRONIC CONTROL PANEL
12.
Press the scroll button again; the display will show:
Exit
Press the up or down button to save the program into the NOVRAM® and exit the programming level. only for PF-SOF1-ALT & PF-SOF1,5-ALT
The 2 Simplex systems, that make up a Duplex system, must be programmed individually; the program does NOT necessarily have to be the same on the 2 Simplex systems!
1.
Press the scroll button and hold it for 6 sec until the display shows:
System Check
2.
Within 10 sec, press the up button; the display will show:
Units: Metric
Press the up or down button to set the units of measure (Metric or US) .
3.
Press the scroll button again; the display will show:
MaintInt: 24 mths
Press the up or down button to activate the maintenance reminder function by setting the maintenance interval, or deactivate the maintenance reminder function .
4.
Press the scroll button again; the display will show:
ExCap: 5.5
°f M3/L
Press the up or down button to set the exchange capacity per litre of resin .
5.
Press the scroll button again; the display will show:
Age corr.: 2.0
%
Press the up or down button to set the age correction factor (%/year) to compensate for capacity loss of the resin due to aging.
6.
Press the scroll button again; the display will show:
Resin:
Press the of resin . up
XXX
or liters down button to set the volume
7.
Press the scroll button again; the display will show:
Override: 7 days
Press the up or down button to set the number of days between regenerations .
8.
Press the scroll button again; the display will show:
Cycle 1: XX min
Press the up or down button to set the length
of the regeneration cycle .
Press the scroll button again to advance to the next regeneration cycle.
Page 13
ELECTRONIC CONTROL PANEL
Cycle 1 Backwash
Cycle 2 Brine draw/slow rinse
Cycle 3 Fast rinse/brine tank refill (PF-SOF1)
Fast rinse (PF-SOF1,5)
Cycle 4 Brine tank refill (PF-SOF1,5)
9.
Press the scroll button again; the display will show:
Exit
Press the up or down button to save the program into the NOVRAM® and exit the programming level.
10.
Repeat steps 1-9 for both Simplex systems. only for PF-SOF1-PRL & PF-SOF1,5-PRL
The 2 Simplex systems, that make up a Duplex system, must be programmed individually; the program does NOT necessarily have to be the same on the 2 Simplex systems!
1.
Press the scroll button and hold it for 6 sec until the display shows:
System Check
2.
Within 10 sec, press the up button; the display will show:
Units: Metric
Press the up or down button to set the units of measure (Metric or US) .
3.
Press the scroll button again; the display will show:
MaintInt: 24 mths
Press the up or down button to activate the maintenance reminder function by setting the maintenance interval, or deactivate the maintenance reminder function .
4.
Press the scroll button again; the display will show:
ExCap: 5.5
°f M3/L
Press the up or down button to set the exchange capacity per litre of resin .
5.
Press the scroll button again; the display will show:
Age corr.: 2.0
%
Press the up or down button to set the age correction factor (%/year) to compensate for capacity loss of the resin due to aging .
6.
Press the scroll button again; the display will show:
Resin:
Press the of resin . up
XXX
or liters down button to set the volume
7.
Press the scroll button again; the display will show:
Override: 7 days
Press the up or down button to set the number of days between regenerations .
8.
Press the scroll button again; the display will show:
Cycle 1: XX min
Press the up or down button to set the length
of the regeneration cycle .
Press the scroll button again to advance to the next regeneration cycle.
Page 14
ELECTRONIC CONTROL PANEL
Cycle 1 Backwash
Cycle 2 Brine draw/slow rinse
Cycle 3 Fast rinse/brine tank refill (PF-SOF1)
Fast rinse (PF-SOF1,5)
Cycle 4 Brine tank refill (PF-SOF1,5)
9.
Press the scroll button again; the display will show:
Regen:Immediate
Press the up or down button to set the regeneration mode :
Immediate : when the remaining capacity equals
0, an immediate regeneration is started.
Note: Delayed manual regeneration is not available when this regeneration mode is selected.
Dlyd/Immd : when the remaining capacity equals the reserve capacity, a delayed regeneration at the programmed time of regeneration is started; however when the remaining capacity equals 0 before the programmed time of regeneration is reached, an immediate regeneration is started.
Delayed : when the remaining capacity equals the reserve capacity, a delayed regeneration at the programmed time of regeneration is started.
10.
Press the scroll button again; the display will show
(only when the regeneration mode is set to ‘ Delayed ’ or
‘ Dlyd/Immd ’ ):
Regen @ 2:00
Press the up or down button to set the time of regeneration .
11.
Press the scroll button again; the display will show
(only when the regeneration mode is set to ‘ Delayed ’ or
‘ Dlyd/Immd ’ ):
Rsrv Variable
Press the up or down button to set the reserve capacity :
Variable : the reserve capacity is calculated automatically, based on the registered daily water usage.
Fxd : press the scroll button again and press the up or down button to set the reserve capacity to a fixed amount .
12.
Press the scroll button again; the display will show:
Exit
Press the up or down button to save the program into the NOVRAM® and exit the programming level.
13.
Repeat steps 1-12 for both Simplex systems.
DIAGNOSTICS MODE
In the Diagnostics mode several operating parameters can be consulted; particularly during a service intervention, these parameters can be helpful to identify the cause of a problem or malfunction.
Before entering the Diagnostics mode, make sure that the appliance is in service mode.
In case no button is pressed in a period of 5 min, the control panel will automatically return to the service mode!
Accessing the Diagnostics mode
1.
Press the scroll button and hold it for 6 sec until the display shows:
System Check
2.
Within 10 sec, press the down button; the display will show:
Regen XXdays ago
You are now in the Diagnostics mode.
Press the scroll button to advance to the next diagnostics parameter.
Available diagnostics parameters
Regen X days ago : number of days since last regeneration.
In Srvc : total number of days in service.
# of Regens : number of regenerations since installation.
TotVol : total volume of treated water since installation.
LastRgn@ : consumed capacity at last regeneration.
InstFlow : instantaneous flow rate through appliance.
AvgVol : calculated average daily water usage.
Capacity : calculated capacity between regenerations.
Hardness : setting of water hardness.
Rsrv : setting of reserve capacity.
Regen @ : setting of time of regeneration.
Override : setting of number of days between regenerations.
Cycle X : setting of length of corresponding regeneration
cycle.
Units : control is programmed for Metric units.
MTR : setting of the water meter.
Capacity : control is programmed for hardness setting.
Regen : setting of the regeneration mode.
Valve Type : setting of valve type.
MP Resets : number of resets of the microprocessor.
Memory Reset : number of corrupt memory start-ups.
EZRSDg : software version.
CapToUse : remaining capacity.
Exiting the Diagnostics mode
1.
Press the scroll button repeatedly until the display shows:
Exit
Press the up or down button to exit the
Diagnostics mode.
Page 15
MAINTENANCE
RECOMMENDATION
Notwithstanding the reliability of the appliance, we strongly recommend to have it serviced and maintained on a regular basis by a competent and duly trained technician. He will be able to determine the appropriate maintenance interval for the appliance, depending on your specific application and the local operating conditions. The advantages of performing regular maintenance are:
regular check of the local operating conditions (water quality, pressure, etc);
regular control and adjustment of the settings of the appliance, to guarantee it operates at maximum efficiency;
minimize the risk of unexpected break-down.
Contact your dealer or installer for more information, or visit our website.
WATER CONDITIONER SALT
This appliance needs 'brine' for its periodic regenerations.
This brine solution is made from water, that is automatically dosed in the brine tank by the control valve, and water conditioner salt. The user should make sure that the brine tank is always kept full of water conditioner salt. Therefore he should periodically check the salt level inside the brine tank and refill it if necessary. Simply lift the brine tank cover to check the salt level inside the brine tank.
Ideally the level of water conditioner salt inside the brine tank is kept between 1/3 and 2/3. A lower level of water conditioner salt can cause insufficient brine saturation, resulting in a loss of softening capacity. A higher level of water conditioner salt can cause salt bridging (hard crust or salt bridges in the brine tank). When you suspect salt bridging:
carefully pound on the outside of the brine tank to break loose the salt bridges;
using a broom (or like blunt tool) carefully push the salt to break it apart;
pour warm water over the top of the salt to dissolve it.
ROUTINE CHECKS
Regularly the user should perform a basic check to verify if the appliance is functioning correctly, on the basis of the following control points:
1.
Check settings of electronic control panel.
2.
Measure water hardness before/after appliance.
3.
Check drain line f rom control valve; there shouldn’t be any water flow (unless appliance is in regeneration).
4.
Check drain line from brine tank overflow; there shouldn’t be any water flow.
5.
Check appliance and surrounding area; there shouldn’t be any water leakages.
BYPASSING THE APPLIANCE
Occasionally it may be necessary to put the appliance hydraulically in bypass, i.e. to isolate it from the water distribution system; f.e.:
in case of an urgent technical problem;
when it is not necessary to supply treated water to the application.
WITH FACTORY BYPASS (optional) (only for PF-SOF1)
Picture 15.a
SERVICE POSITION
= inlet valve to appliance is OPEN
= outlet valve from appliance is OPEN
Picture 15.b
BYPASS POSITION
= inlet valve to appliance is CLOSED
= outlet valve from appliance is CLOSED
RESIN CLEANER
Other contaminants (f.e. iron) present in the feed water can cause the resin bed to foul up, resulting in a loss of softening capacity. An approved resin cleaner can be used periodically to thoroughly clean the resin bed.
SANITIZING THE APPLIANCE
This appliance is manufactured from premium quality material and assembled in safe conditions to assure it is clean and sanitary. If installed and serviced correctly, this appliance will not infect or contaminate your water supply. However, as in any 'device' plumbed-in in your water distribution system, a proliferation of bacteria is possible, especially in case of
'stagnant water'. Therefore this appliance is equipped with a
'days override' feature, that will automatically rinse the resin bed periodically, even in case of low or absence of water usage.
If the power supply to the appliance is disconnected for a longer period of time, we recommend, when the power supply is re-established, to manually initiate a complete regeneration.
NORMALLY CLOSED SERVICE VALVES
(only for PF-SOF1-ALT & PF-SOF1,5-ALT)
Picture 15.c
MAINTENANCE POSITION
= inlet valve to appliance is OPEN
= outlet valve from appliance is CLOSED
Picture 16
= automatically operated = normally closed
= manually operated = constantly open
The Normally Closed Service Valve in the outlet of each
Simplex system will only be opened when it is powered. To manually open the Normally Closed Service Valve (f.e. in case of a power failure), simply turn the white solenoid coil counter clockwise.
Page 16
Page 17
TROUBLESHOOTING
PROBLEM
Hard (untreated) water to service
Residual hardness in treated water
Appliance fails to start a regeneration
Appliance uses too much salt
Excessive water in brine tank
Salt taste in treated water
Loss of water pressure valve flows continuously
Drain line from control
CAUSE
Open or defective bypass
Simplex only : appliance in regeneration
Duplex only : one of the Simplex systems in regeneration and Service Valve not closing off properly
No salt in brine tank
Salt bridging in brine tank
Change in raw water hardness
Appliance fails to start a regeneration
Add salt and initiate regeneration manually
Break salt bridge(s) and initiate regeneration manually
Measure hardness of incoming untreated water and adjust programming accordingly
Refer to problem “ Appliance fails to start a regeneration ”
Synchronize valve body and timer PF-SOF1 only : valve body and timer out of synchronisation
Control valve fails to draw brine
Decreasing exchange capacity of resin
Loss of resin
Leak at riser tube
SOLUTION
Close or replace bypass
Wait until regeneration finishes or manually advance regeneration to end
Refer to problem “Service Valve not closing off properly”
Bypass not completely closed
PF-SOF1 only : mixing valve open
Faulty electrical supply
Defective flow meter
Defective PCB
Defective drive motor
Excessive water in brine tank
Appliance regenerates too frequently
Control valve fails to draw brine
Improper refill time setting
Missing refill flow control
Leak from control valve to brine tank
Excessive water in brine tank
Injector undersized
Improper brine/slow rinse time setting
Mineral or iron build-up in resin tank
Plugged lower and/or upper distributor
Appliance in regeneration
Faulty electrical supply
Defective drive motor
PF-SOF1 only : defective micro switch
PF-SOF1,5 only
Defective PCB
: defective optical switch
PF-SOF1 only : valve body and timer out of synchronisation
Excessive water in brine tank
Refer to problem “Valve fails to draw brine”
Clean or replace resin bed
Refer to problem “Loss of resin”
Verify that riser tube is seated correctly and is not cracked
Close bypass
Verify setting of mixing valve
Verify electrical service (fuse, transformer,...)
Clean and/or replace flow meter
Replace PCB
Replace drive motor
Refer to problem “Excessive water in brine tank ”
Verify program
Refer to problem “Control valve fails to draw brine”
Verify that refill time corresponds to the proper salt level and amount of resin
Verify that refill flow control is installed and properly sized
PF-SOF1 only : check synchronisation between valve body and timer
PF-SOF1,5 only : check brine line shut-off valve of valve body
Refer to problem “Excessive water in brine tank”
Verify injector selection and operating pressure
Verify that brine/slow rinse time corresponds to the proper salt level and amount of resin
Clean resin bed and control valve; increase regeneration frequency
Verify that distributors are free of debris
Wait until regeneration finishes or manually advance regeneration to end
Verify electrical service (fuse, transformer,...)
Replace drive motor
Replace micro switches
Replace optical switch
Replace PCB
Synchronise valve body and timer
Refer to problem “Excessive water in brine tank ” Drain line from brine tank overflow flows continuously
Page 18
PROBLEM
Control valve fails to refill brine tank
Loss of resin
Control valve fails to draw brine
Control valve cycles continuously
Duplex Parallel: both
Simplex systems regenerate simultaneously
Duplex Alternating: both Simplex systems are in service simultaneously
TROUBLESHOOTING
CAUSE
Plugged injector
Restricted drain line
Restricted brine line
Leak in brine line
No water in brine tank
SOLUTION
Improper refill time setting Verify that refill time corresponds to salt level and amount of resin
Plugged refill flow control
Lower and/or upper distributor damaged
Clean refill flow control
Replace distributor(s)
Leak between riser tube and upper distributor Verify that riser tube is seated correctly and is not cracked
Low operating pressure Check operating pressure; must be higher than 1,4 bar
Clean injector
Verify drain line for kinks or restrictions
Verify brine line for kinks or restrictions
Verify brine line and connections for air leakage
Refer to problem “Control v alve fails to refill brine tank”
PF-SOF1 only : defective micro switch
PF-SOF1,5 only : defective optical switch
InterConnect communication does not function correctly
Defective PCB
Replace micro switches
Replace optical switch
Check connections of InterConnect cable(s)
Replace PCB
InterConnect communication does not function correctly
Defective PCB
Defective Service Valve
Check connections of InterConnect cable
Replace PCB
Replace Service Valve
Page 19
ELECTRICAL WIRING DIAGRAMS
PF-SOF1
= position switches
= flow meter
= power lead
= drive motor
= PF-SOF1-SIM: service valve NO (optional)
PF-SOF1-PRL: service valve NO
PF-SOF1-ALT: service valve NC
= InterConnect socket
= key pad
PF-SOF1,5
= optical switch
= flow meter
= power lead
= drive motor
= PF-SOF1,5-SIM: service valve NO (optional)
PF-SOF1,5-PRL: service valve NO
PF-SOF1,5-ALT: service valve NC
= InterConnect socket
= key pad
Page 20
DEFAULT CONFIGURATION PARAMETER SETTINGS - PF-SOF1
PF-SOF1-SIM Model
Resin
Units
MaintInt (mths)
Exchange capacity per liter resin (°f M 3 /L) (1) (2)
Age correction (%)
Resin (liters)
Override (days)
Cycle 1: BACKWASH (min)
Cycle 2: BRINE DRAW/SLOW RINSE (min)
Cycle 3: FAST RINSE/REFILL (min) (2)
Regen
Regen @
25
Metric
24
5,5
2.0
25
7
5
48
6
50
Metric
24
5,5
2.0
50
7
5
76
6
75
Metric
24
5,5
2.0
75
7
5
104
9
100
Metric
24
5,5
2.0
100
7
5
77
12
150
Metric
7
5
87
17
24
5,5
2.0
150
Dlyd/Immd Dlyd/Immd Dlyd/Immd Dlyd/Immd Dlyd/Immd
2:00 2:00 2:00 2:00 2:00
Rsrv Variable Variable Variable Variable Variable
(1) When the Hardness Unit is changed in the Basic Settings, the Exchange capacity per liter resin is automatically converted to the new Hardness Unit.
(2) When the Exchange capacity per liter resin is changed, the refill cycle time needs to be adjusted accordingly.
Model PF-SOF1-ALT
Resin 25 50 75 100 150
Metric Metric Metric Metric Metric Units
MaintInt (mths)
Exchange capacity per liter resin (°f M 3 /L) (1)(2)
Age correction (%)
Resin (liters)
Override (days)
Cycle 1: BACKWASH (min)
24
5,5
2.0
25
7
5
24
5,5
2.0
50
7
5
24
5,5
2.0
75
7
5
24
5,5
2.0
100
7
5
24
5,5
2.0
150
7
5
Cycle 2: BRINE DRAW/SLOW RINSE (min)
Resin
48
Cycle 3: FAST RINSE/REFILL (min) (2) 6 6 9 12 17
(1) When the Hardness Unit is changed in the Basic Settings, the Exchange capacity per liter resin is automatically converted to the new Hardness Unit.
(2) When the Exchange capacity per liter resin is changed, the refill cycle time needs to be adjusted accordingly.
Model PF-SOF1-PRL
25
76
50
104
75
77
100
87
150
Metric Metric Metric Metric Metric Units
MaintInt (mths)
Exchange capacity per liter resin (°f M 3 /L) (1)(2)
24
5,5
24
5,5
24
5,5
24
5,5
24
5,5
Age correction (%)
Resin (liters)
Override (days)
Cycle 1: BACKWASH (min)
Cycle 2: BRINE DRAW/SLOW RINSE (min)
Cycle 3: FAST RINSE/REFILL (min) (2)
2.0
25
7
5
48
6
2.0
50
7
5
76
6
2.0
75
7
5
104
9
2.0
100
7
5
77
12
2.0
150
7
5
87
17
Regen Immediate Immediate Immediate Immediate Immediate
(1) When the Hardness Unit is changed in the Basic Settings, the Exchange capacity per liter resin is automatically converted to the new Hardness Unit.
(2) When the Exchange capacity per liter resin is changed, the refill cycle time needs to be adjusted accordingly.
Page 21
DEFAULT CONFIGURATION PARAMETER SETTINGS - PF-SOF1,5
Model
Resin
Units
MaintInt (mths)
Exchange capacity per liter resin (°f M 3 /L) (1)(2)
Age correction (%)
Resin (liters)
Override (days)
Cycle 1: BACKWASH (min)
Cycle 2: BRINE DRAW/SLOW RINSE (min)
Cycle 3: FAST RINSE (min) (2)
Cycle 4: REFILL (min)
Regen
75
Metric
24
5,5
2.0
75
7
5
43
11
5
100
Metric
24
5,5
2.0
100
7
5
39
14
7
150
Metric
24
5,5
2.0
150
7
5
58
17
10
PF-SOF1,5-SIM
200
Metric
24
5,5
2.0
7
5
42
16
8
200
250
Metric
24
5,5
2.0
7
5
53
16
10
250
350
Metric
24
5,5
2.0
7
5
62
13
14
350
500
Metric
24
5
88
14
20
5,5
2.0
500
7
Dlyd/Immd Dlyd/Immd Dlyd/Immd Dlyd/Immd Dlyd/Immd Dlyd/Immd Dlyd/Immd
Regen @ 2:00 2:00 2:00 2:00 2:00 2:00 2:00
Rsrv Variable Variable Variable Variable Variable Variable Variable
(1) When the Hardness Unit is changed in the Basic Settings, the Exchange capacity per liter resin is automatically converted to the new Hardness Unit.
(2) When the Exchange capacity per liter resin is changed, the refill cycle time needs to be adjusted accordingly.
Model PF-SOF1,5-ALT
Resin
Units
MaintInt (mths)
Exchange capacity per liter resin (°f M
Age correction (%)
Resin (liters)
Override (days)
Cycle 1: BACKWASH (min)
Cycle 3: FAST RINSE (min) (2)
3 /L) (1)(2)
Cycle 2: BRINE DRAW/SLOW RINSE (min)
5,5
2.0
75
7
5
43
11
5,5
2.0
100
7
5
39
14
5,5
2.0
150
7
5
58
17
5,5
2.0
200
7
5
42
16
5,5
2.0
250
7
5
53
16
5,5
2.0
350
7
5
62
13
Cycle 4: REFILL (min) 5 7 10 8 10 14
(1) When the Hardness Unit is changed in the Basic Settings, the Exchange capacity per liter resin is automatically converted to the new Hardness Unit.
(2) When the Exchange capacity per liter resin is changed, the refill cycle time needs to be adjusted accordingly.
Model PF-SOF1,5-PRL
Resin
Units
MaintInt (mths)
75 100 150 200 250 350 500
Metric Metric Metric Metric Metric Metric Metric
24 24 24 24 24 24 24
5,5
2.0
500
7
5
88
14
20
75 100 150 200 250 350 500
Metric Metric Metric Metric Metric Metric Metric
24 24 24 24 24 24 24
Exchange capacity per liter resin (°f M 3 /L) (1)(2)
Age correction (%)
Resin (liters)
Override (days)
Cycle 1: BACKWASH (min)
Cycle 2: BRINE DRAW/SLOW RINSE (min)
Cycle 3: FAST RINSE (min) (2)
5,5
2.0
75
7
5
43
11
5,5
2.0
100
7
5
39
14
5,5
2.0
150
7
5
58
17
5,5
2.0
200
7
5
42
16
5,5
2.0
250
7
5
53
16
5,5
2.0
350
7
5
62
13
5,5
2.0
500
7
5
88
14
Cycle 4: REFILL (min) 5 7 10 8 10 14 20
Regen Immediate Immediate Immediate Immediate Immediate Immediate
(1) When the Hardness Unit is changed in the Basic Settings, the Exchange capacity per liter resin is automatically converted to the new Hardness Unit.
(2) When the Exchange capacity per liter resin is changed, the refill cycle time needs to be adjusted accordingly.
Immediate
Page 22
Model
Resin volume ltr
PN
2 x 25
2 x 50
2 x 75
2 x 100
2 x 150
25
50
75
100
150
2 x 25
2 x 50
2 x 75
2 x 100
35820
35821
35822
35823
2 x 150
(1) NC = Normally Closed
(2) NO = Normally Open
35824
Model
Resin volume
PN
35810
35811
35812
35813
35814
35815
35816
35817
35818
35819 ltr
2 x 75
2 x 100
2 x 150
2 x 200
2 x 250
2 x 350
2 x 500
75
100
150
200
250
350
500
2 x 75
2 x 100
2 x 150
2 x 200
2 x 250
2 x 350
35843
35844
2 x 500
(1) NC = Normally Closed
(2) NO = Normally Open
35845
35832
35833
35834
35835
35836
35837
35838
35825
35826
35827
35828
35829
35830
35831
35839
35840
35841
35842
COMPOSITION OVERVIEW
Control valve, incl. transformer,
1” BSP Male connections model #
2400VS/J4JB/PRL1
2400VS/J1KD/PRL1
2400VS/J1LD/PRL1
2400VS/J2MD/PRL1
2400VS/J2ND/PRL1
2400VS/J4JB/ALT
2400VS/J1KD/ALT
2400VS/J1LD/ALT
2400VS/J2MD/ALT
2400VS/J2ND/ALT
2400VS/J4JB/PRL1
2400VS/J1KD/PRL1
2400VS/J1LD/PRL1
2400VS/J2MD/PRL1
2400VS/J2ND/PRL1
2
2
2
2
2
1
1
1
1
1
2
2
2
2
2
InterConnect cable
#
1
1
1
1
1
0
0
0
0
0
1
1
1
1
1
Service Valve
1” BSP Female model #
2
2
2
2
2
2
2
2
2
2
0
0
0
0
0
NC (1)
NC (1)
NC (1)
NC (1)
NC (1)
/
/
/
/
/
NO (2)
NO (2)
NO (2)
NO (2)
NO (2)
Pressure tank, incl. distributor assy model #
10x35
12x48
13x54
14x65
16x65
10x35
12x48
13x54
14x65
16x65
10x35
12x48
13x54
14x65
16x65
2
2
2
2
2
1
1
1
1
1
2
2
2
2
2
Resin
(25 ltr bag)
#
6
8
2
4
12
3
4
1
2
6
6
8
2
4
12
Control valve, incl. transformer, flow meter, 1,5” BSP Male connections model #
EV1.5VS/J/5A/40/12
EV1.5VS/J/5A/50/12
EV1.5VS/J/5A/60/12
EV1.5VS/J/5/80/20
EV1.5VS/J/5/100/20
EV1.5VS/J/6/150/20
EV1.5VS/J/6/200/20
EV1.5VS/J/5A/40/12/ALT
EV1.5VS/J/5A/50/12/ALT
EV1.5VS/J/5A/60/12/ALT
EV1.5VS/J/5/80/20/ALT
EV1.5VS/J/5/100/20/ALT
EV1.5VS/J/6/150/20/ALT
EV1.5VS/J/6/200/20/ALT
EV1.5VS/J/5A/40/12
EV1.5VS/J/5A/50/12
EV1.5VS/J/5A/60/12
EV1.5VS/J/5/80/20
EV1.5VS/J/5/100/20
EV1.5VS/J/6/150/20
EV1.5VS/J/6/200/20
2
2
2
2
2
2
2
1
1
1
1
1
1
1
2
2
2
2
2
2
2
InterConnect cable
#
1
1
1
1
1
1
1
0
0
0
0
0
0
0
1
1
1
1
1
1
1
Service Valve
1,5” BSP Female
Model #
2
2
2
2
2
2
2
0
0
0
0
0
0
0
2
2
2
2
2
2
2
NC (1)
NC (1)
NC (1)
NC (1)
NC (1)
NC (1)
NC (1)
/
/
/
/
/
/
/
NO (2)
NO (2)
NO (2)
NO (2)
NO (2)
NO (2)
NO (2)
Pressure tank, incl. distributor assy model #
13x54
14x65
16x65
18x65
21x62
24x72
30x72
13x54
14x65
16x65
18x65
21x62
24x72
30x72
13x54
14x65
16x65
18x65
21x62
24x72
30x72
2
2
2
2
2
2
2
1
1
1
1
1
1
1
2
2
2
2
2
2
2
Resin
(25 ltr bag)
#
20
28
40
6
8
12
16
10
14
20
6
8
3
4
20
28
40
6
8
12
16
Page 23
EXPLODED VIEW - PF-SOF1-SIM
Page 24
Item PN
6
7
4
5
2
3
1 PT/1035/BA
PT/1248/BA
PT/1354/BA
PT/1465/BA
PT/1665/BA
E8000
38534
28/298/11
28/298/18
287/166
2400VS/J4JB/PRL1
2400VS/J1KD/PRL1
2400VS/J1LD/PRL1
2400VS/J2MD/PRL1
2400VS/J2ND/PRL1
568/303/1
8
9
H1015/2
38522
10 74163
11 38521
(*) Recommended Spare Part
EXPLODED VIEW - PF-SOF1-SIM
Description
Pressure tank 10x35
Pressure tank 12x48
Pressure tank 13x54
Pressure tank 14x65
Pressure tank 16x65
Softening resin
Riser tube assembly
Transformer 230/24V - 50 Hz, 24VA, EuroT plug
Transformer 230/24V - 50 Hz, 24VA, UK plug
Top distributor
Control valve
Control valve
Control valve
Control valve
Control valve
Connection kit 1” BSP male
Brine line polytube
Drain hose
Air gap with double hose barb
Clamp, drain hose (2x)
Remark
25 Ltr
50 Ltr
75 Ltr
100 Ltr
150 Ltr multiple of 25 ltr to be cut to length
25 Ltr
50 Ltr
75 Ltr
100 Ltr
150 Ltr to be ordered per meter to be ordered per meter
(*)
Page 25
EXPLODED VIEW - PF-SOF1-ALT & PF-SOF1-PRL
Page 26
Item PN
6
7
4
5
2
3
1
8 74136
74137
9 74089
10 H1015/2
11 74069
12 38522
PT/1035/BA
PT/1248/BA
PT/1354/BA
PT/1465/BA
PT/1665/BA
E8000
38534
28/298/11
28/298/18
287/166
2400VS/J4JB/ALT
2400VS/J1KD/ALT
2400VS/J1LD/ALT
2400VS/J2MD/ALT
2400VS/J2ND/ALT
2400VS/J4JB/PRL1
2400VS/J1KD/PRL1
2400VS/J1LD/PRL1
2400VS/J2MD/PRL1
2400VS/J2ND/PRL1
568/303/1
13 74163
14 38521
(*) Recommended Spare Part
EXPLODED VIEW - PF-SOF1-ALT & PF-SOF1-PRL
Description
Pressure tank 10x35
Pressure tank 12x48
Pressure tank 13x54
Pressure tank 14x65
Pressure tank 16x65
Softening resin
Riser tube assembly
Transformer 230/24V - 50 Hz, 24VA, EuroT plug
Transformer 230/24V - 50 Hz, 24VA, UK plug
Top distributor
Control valve for Duplex Alternating
Control valve for Duplex Alternating
Control valve for Duplex Alternating
Control valve for Duplex Alternating
Control valve for Duplex Alternating
Control valve for Duplex Parallel
Control valve for Duplex Parallel
Control valve for Duplex Parallel
Control valve for Duplex Parallel
Control valve for Duplex Parallel
Connection kit 1” BSP male
Service valve, Normally Closed
Service valve, Normally Open
Brass adaptor 1” male
Brine line polytube
InterConnect cable
Drain hose
Air gap with double hose barb
Clamp, drain hose (4x)
Remark
25 Ltr
50 Ltr
75 Ltr
100 Ltr
150 Ltr multiple of 25 ltr to be cut to length
PF-SOF1-ALT-25 Ltr
PF-SOF1-ALT-50 Ltr
PF-SOF1-ALT-75 Ltr
PF-SOF1-ALT-100 Ltr
PF-SOF1-ALT-150 Ltr
PF-SOF1-PRL-25 Ltr
PF-SOF1-PRL-50 Ltr
PF-SOF1-PRL-75 Ltr
PF-SOF1-PRL-100 Ltr
PF-SOF1-PRL-150 Ltr
PF-SOF1-ALT
PF-SOF1-PRL to be ordered per meter to be ordered per meter
(*)
Page 27
EXPLODED VIEW - PF-SOF1 - TIMER ASSEMBLY
Page 28
Item PN
1
2
3
70971
72263
72519
6
7
8
4
5
28/8/7
71502
15/222
74135
72369
9 75157
10 15/222
11 74267
12 70312
13 74105
14 75158
15 72261
16 75156
17 70965
18 568/386
19 568/310
20 15/184/7
21 15/173/12
22 72451
23 71679
24 15/102
25 74167
74106
26 72614
(*) Recommended Spare Part
EXPLODED VIEW - PF-SOF1 - TIMER ASSEMBLY
Description
Power lead with plug
Clamp
Flow meter cable
Strain relief, flow meter cable
Screw, timer cover (3x)
Screw, back plate (2x)
Socket and cable assembly, Service Valve
Back plate
Worm coupling
Screw, drive motor assembly (2x)
Cable clamp
Strain relief, power lead
Socket & cable assembly, InterConnect
Retaining ring, worm drive shaft
Drive motor
Worm drive shaft
Switch cam
Bracket, micro switches
Gear, switch cam
Locking screw, switch cam
Screw, micro switches (2x)
Micro switch assy
Cable set, drive motor
Screw, PCB (2x)
Printed Circuit Board, Alternating
Printed Circuit Board, Simplex & Parallel
Timer cover assembly
Remark
PF-SOF1-ALT
PF-SOF1-SIM & PF-SOF1-PRL
(*)
Page 29
EXPLODED VIEW - PF-SOF1 - VALVE BODY
Page 30
Item PN
30 21/88
31 541/254
32 570/251
33 568/334
34 185/214/1
35 185/337/1
36 541/232
37 15/207/12
38 72772
39 185/211/1
40 186/115
41 568/208/2
42 14/43
43 EB64/33
44 568/340
45 185/208/1
46 26/47/12N
47 72801
1
2
3
4
5
21/83
568/271/J
568/271/K
568/271/L
568/271/M
568/271/N
72678
568/254/3
185/154/1
6
7
8
186/112
72327
568/260
9 568/259
10 185/041/1
11 568/345/2
12 568/256
13 568/383
14 568/384
15 51/5/105
16 568/270/4
17 568/274/4
568/274/1
568/274/2
18 72458
19 72544
20 72545
21 185/007/6
22 568/406
23 186/118
24 568/407/L
25 568/385/2/B
568/385/2/D
26 186/118
27 568/336
28 541/275
29 413/62
A RK/568/259/2
B RK/75154
C RK/568/406
(*) Recommended Spare Part
Description
Drain connection
Drain Line Flow Control J (9,8 Ltr/min)
Drain Line Flow Control K (13,2 Ltr/min)
Drain Line Flow Control L (15,1 Ltr/min)
Drain Line Flow Control M (18,9 Ltr/min)
Drain Line Flow Control N (22,7 Ltr/min)
Bolt, valve cover (6x)
Valve cover
O-ring, valve cover
O-ring, Teflon
Washer, PE
Worm gear
Rotor cam
O-ring, rotor
Rotor plate
Seal disk
Insert plate
Gasket
Spring, float valve
Float valve
Injector (purple)
Injector (red)
Injector (yellow)
Diffuser, impeller
Impeller
Hub, impeller
O-ring, mixing valve
Mixing valve
O-ring, sleeve
Sleeve, mixing valve
Refill Flow Control 1,9 ltr/min
Refill Flow Control 3,8 ltr/min
O-ring, refill elbow
Refill elbow ⅜”
Check ball, refill elbow
Spring, refill elbow
Nut, refill elbow/brine tee
Spring clip
Gasket, riser
Riser insert
O-ring, riser tube
O-ring, tank
Adapter ring
Screw, adapter ring (2x)
Packing gland nut (plastic)
O-ring, packing gland nut
O-ring, worm drive shaft (2x)
Worm drive shaft
Washer, worm drive shaft
Refill tube
Brine Tee ⅜”
O-ring, brine tee
Check ball, brine tee
Valve body
Repair kit rotor
Repair kit packing gland nut
Repair kit mixing valve
EXPLODED VIEW - PF-SOF1 - VALVE BODY
Remark
25 Ltr
50 Ltr
75 Ltr
100 Ltr
150 Ltr
25 Ltr
50 Ltr, 75 Ltr
100 Ltr, 150 Ltr
Eco
Eco
Eco
25 Ltr
50 Ltr, 75 Ltr, 100 Ltr, 150 Ltr
Page 31
(*)
EXPLODED VIEW - PF-SOF1,5-SIM
Page 32
Item PN
2
3
1 PT/1354/4/BA
PT/1465/4/BA
PT/1665/4/BA
PT/1865/4/BA
PT/2162/4/BA
PT/2472/4/BA
PT/3072/4/BA
E8000
39107
4
5
EV/TD
EV/20533
6
7
28/500/11/IL
28/500/18/IL
EV1.5VS/J/5A/40/12
EV1.5VS/J/5A/50/12
EV1.5VS/J/5A/60/12
EV1.5VS/J/5/80/20
EV1.5VS/J/5/100/20
EV1.5VS/J/6/150/20
EV1.5VS/J/6/200/20
8 H1015/5
(*) Recommended Spare Part
EXPLODED VIEW - PF-SOF1,5-SIM
Description
Pressure tank 1 3x54, 4” top opening
P ressure tank 14x65, 4” top opening
Pressure tank 16 x65, 4” top opening
P ressure tank 18x65, 4” top opening
P ressure tank 21x62, 4” top opening
P ressure tank 24x72, 4” top opening
P ressure tank 30x72, 4” top opening
Softening resin
Riser tube assembly
Top distributor
Screw, top distributor
Transformer 230/24V - 50 Hz, 120VA, EuroT plug
Transformer 230/24V - 50 Hz, 120VA, UK plug
Control valve
Control valve
Control valve
Control valve
Control valve
Control valve
Control valve
Brine line polytube
Remark
75 Ltr
100 Ltr
150 Ltr
200 Ltr
250 Ltr
350 Ltr
500 Ltr multiple of 25 ltr to be cut to length
75 Ltr
100 Ltr
150 Ltr
200 Ltr
250 Ltr
350 Ltr
500 Ltr to be ordered per meter
(*)
Page 33
EXPLODED VIEW - PF-SOF1,5-ALT & PF-SOF1,5-PRL
Page 34
EXPLODED VIEW - PF-SOF1,5-ALT & PF-SOF1,5-PRL
Item PN
2
3
1 PT/1354/4/BA
PT/1465/4/BA
PT/1665/4/BA
PT/1865/4/BA
PT/2162/4/BA
PT/2472/4/BA
PT/3072/4/BA
E8000
39107
Description
Pressure tank 1 3x54, 4” top opening
P ressure tank 14x65, 4” top opening
Pressure tank 16 x65, 4” top opening
P ressure tank 18x65, 4” top opening
P ressure tank 21x62, 4” top opening
P ressure tank 24x72, 4” top opening
P ressure tank 30x72, 4” top opening
Softening resin
Riser tube assembly
7
6
4
5
8
9
EV/TD
EV/20533
H1015/5
74210
74208
Top distributor
Screw, top distributor
28/500/11/IL
28/500/18/IL
Transformer 230/24V - 50 Hz, 120VA, EuroT plug
Transformer 230/24V - 50 Hz, 120VA, UK plug
EV1.5VS/J/5A/40/12/ALT Control valve for Duplex Alternating
EV1.5VS/J/5A/50/12/ALT Control valve for Duplex Alternating
EV1.5VS/J/5A/60/12/ALT Control valve for Duplex Alternating
EV1.5VS/J/5/80/20/ALT Control valve for Duplex Alternating
EV1.5VS/J/5/100/20/ALT Control valve for Duplex Alternating
EV1.5VS/J/6/150/20/ALT Control valve for Duplex Alternating
EV1.5VS/J/6/200/20/ALT Control valve for Duplex Alternating
EV1.5VS/J/5A/40/12 Control valve for Duplex Parallel
EV1.5VS/J/5A/50/12
EV1.5VS/J/5A/60/12
EV1.5VS/J/5/80/20
EV1.5VS/J/5/100/20
EV1.5VS/J/6/150/20
EV1.5VS/J/6/200/20
Control valve for Duplex Parallel
Control valve for Duplex Parallel
Control valve for Duplex Parallel
Control valve for Duplex Parallel
Control valve for Duplex Parallel
Control valve for Duplex Parallel
Brine line polytube
Service valve, Normally Closed
Service valve, Normally Open
InterConnect cable 10 74069
(*) Recommended Spare Part
Remark
75 Ltr
100 Ltr
150 Ltr
200 Ltr
250 Ltr
350 Ltr
500 Ltr multiple of 25 ltr to be cut to length
PF-SOF1-ALT-75 Ltr
PF-SOF1-ALT-100 Ltr
PF-SOF1-ALT-150 Ltr
PF-SOF1-ALT-200 Ltr
PF-SOF1-ALT-250 Ltr
PF-SOF1-ALT-350 Ltr
PF-SOF1-ALT-500 Ltr
PF-SOF1-PRL-75 Ltr
PF-SOF1-PRL 100 Ltr
PF-SOF1-PRL 150 Ltr
PF-SOF1-PRL 200 Ltr
PF-SOF1-PRL 250 Ltr
PF-SOF1-PRL 350 Ltr
PF-SOF1-PRL 500 Ltr to be ordered per meter
PF-SOF1,5-ALT
PF-SOF1,5-PRL
(*)
Page 35
EXPLODED VIEW PF-SOF1,5 - TIMER ASSEMBLY
Page 36
Item PN
1
2
3
4
EV/11107
EV/20760
EV/20655
EV/11109
7
8
5
6
EV/10624
EV/11108
EV/20656
EV/20657
9 EV/11085
10 EV/11084
11 74267
12 EV/20644/1
13 EV/20648
14 74224
15 74226
16 74105
17 74236
18 EV/10828
19 28/500/11
20 EV/20761
21 74235
22 15/102
23
74223
74222
24 EV/20647
25 EV/20649
26 EV/20653
27 EV/20960
28 EV/11125
29 74206
(*) Recommended Spare Part
EXPLODED VIEW - PF-SOF1,5 - TIMER ASSEMBLY
Description
Cap, brine shut-off valve
Split washer
Spring
Washer
X-ring (2x)
Nut, brine shut-off valve
Rod, brine shut-off valve
Piston, brine shut-off valve
O-ring (2x)
Spacer
Cable clamp
Back plate
Nut, back plate (4x)
Socket and cable assembly, Service Valve
Plug
Socket & cable assembly, InterConnect
Flow meter cable
Strain relief, flow meter cable
Power lead with plug
Screw, optical sensor (2x)
Optical sensor
Screw, PCB (3x)
Printed Circuit Board, Alternating
Printed Circuit Board, Simplex & Parallel
Bolt, back plate (4x)
Bolt, drive motor assembly (2x)
R spring pin
Drive motor assembly
Screw, timer cover (4x)
Timer cover assembly
Remark incl. with transformer
PF-SOF1,5-ALT
PF-SOF1,5-SIM & PF-SOF1,5-PRL
(*)
Page 37
EXPLODED VIEW - PF-SOF1,5 - VALVE BODY
Page 38
Item PN
1
2
3
4
5
6
EV/20660
EV/11101/1
EV/11537
EV/10982
EV/10983
74237
74238
74239
7
8
EV/11118
EV/11097
9 EV/11085
10 EV/11115
11 EV/11092
12 EV/11094-1
13 EV/11093
14 EV/11095
15 EV/11086
16 EV/11088
17 74241
74242
74243
74244
74245
74246
74247
18 EV/11090
19 EV/11089
20 EV/11091
21 EV/83566
22 74219
23 EV/11111
24 74248
74249
25 EV/11110
26 EV/11075
27 EV/11114
28 EV/11113
29 EV/11273
30 EV/11374
31 EV/20658
(*) Recommended Spare Part
EXPLODED VIEW - PF-SOF1,5 - VALVE BODY
Description
Bolt, cover plate (4x)
Cover plate
Plug
Nut, compression connection ½” (3x)
Compression ring ½” (3x)
Injector 5A (red)
Injector 5 (blue)
Injector 6 (orange)
Gasket, cover plate
Injector block
Gasket, injector block adaptor
Gasket, injector block
O-ring, inlet/outlet adaptor (4x)
Inlet/outlet adaptor 1,5” BSP Male (4x)
Nut, inlet/outlet adaptor (4x)
Adaptor, injector block
Adaptor, brine shut-off valve
O-ring, drain adaptor
Drain Line Flow Controller 4.0 GPM
Drain Line Flow Controller 5.0 GPM
Drain Line Flow Controller 6.0 GPM
Drain Line Flow Controller 8.0 GPM
Drain Line Flow Controller 10.0 GPM
Drain Line Flow Controller 15.0 GPM
Drain Line flow Controller 20.0 GPM
Drain adaptor 1” BSP male
Nut, drain adaptor
Connection tube
Flow meter assembly
PVC elbow 1,5” BSP Female
O-ring, brine shut-off valve adaptor
Refill flow control 1.2 GPM
Refill flow control 2.0 GPM
Housing, brine shut-off valve
Front plate
Gasket, valve seat
Valve seat
O-ring, tank
O-ring, riser tube
Bolt, valve seat (4x)
Remark
75 Ltr
100 Ltr
150 Ltr
200 Ltr
250 Ltr
350 Ltr
500 Ltr
75 Ltr, 100 Ltr, 150 Ltr
200 Ltr, 250 Ltr
350 Ltr, 500 Ltr incl.: 2x EV/11092, 2x EV/11094-1,
2x EV/11093
75 Ltr, 100 Ltr, 150 Ltr
200 Ltr, 250 Ltr, 350 Ltr, 500 Ltr
(*)
Page 39
EXPLODED VIEW - PF-SOF1,5 - PISTON ASSEMBLY
Page 40
Item PN
1
2
3
4
7
8
5
6
EV/20646
EV/20654
EV/11104
EV/11105
EV/11080
EV/11082
EV/11081
EV/11078
9 EV/11076
10 EV/11077
(*) Recommended Spare Part
EXPLODED VIEW - PF-SOF1,5 - PISTON ASSEMBLY
Description
Piston
Stem
Bushing
O-ring, bushing (2x)
Seal disk
Spacer (narrow) (2x)
Spacer (wide) (3x)
Compression spacer
End cap
O-ring, end cap
Remark (*)
Page 41
EXPLODED VIEW - PF-BTA SIMPLEX
Item PN
2
1
3
6
7
4
5
BW4/072
BW4/088
BW4/100
H4500/48
8
9
H4640/32
10 474/000
BT/0125
BT/0275
BT/0500
BT/0750
38535
38532
38537
BP/0125/01
BP/0275/01
BP/0500/01
BP/0750/01
11 H4650
12 H1016
13 38522
14 38521
15 74163
(*) Recommended Spare Part
Description
Brine tank 125 Ltr
Brine tank 275 Ltr
Brine tank 500 Ltr
Brine tank 750 Ltr
Fastener (snap rivet & washer), brine well
Overflow assembly
Label ‘ProFlow’
Brine platform for simplex
Brine platform for simplex
Brine platform for simplex
Brine platform for simplex
Brine well Ø10 cm, 72 cm
Brine well Ø10 cm, 88 cm
Brine well Ø10 cm, 100 cm
Air check
Float
Grommet, float (2x)
Brine valve with elbow ⅜” , quick-fit connection
Elbow ½”, compression connection
Brine well lid Ø10 cm
Drain hose
Clamp, drain hose (2x)
Air gap with double hose barb
Page 42
Remark
BT/0125
BT/0275
BT/0500
BT/0750
BT/0125
BT/0275
BT/0500, BT/0750 to be cut to length included in item 8 to be ordered per meter
(*)
EXPLODED VIEW - PF-BTA DUPLEX
Item PN
5
3
4
1
2
6
7
BW4/072
BW4/088
BW4/100
H4500/48
8
9
H4640/32
10 474/000
11 H4650
12 H1016
13 38522
14 38521
BT/0125
BT/0275
BT/0500
BT/0750
38535
38532
38537
BP/0125/02
BP/0275/02
BP/0500/02
BP/0750/02
(*)
15 74163
Recommended Spare Part
Description
Brine tank 125 Ltr
Brine tank 275 Ltr
Brine tank 500 Ltr
Brine tank 750 Ltr
Fastener (snap rivet & washer), brine well (2x)
Overflow assembly
Label ‘ProFlow’
Brine platform for duplex
Brine platform for duplex
Brine platform for duplex
Brine platform for duplex
Brine well Ø10 cm, 72 cm (2x)
Brine well Ø10 cm, 88 cm (2x)
Brine well Ø10 cm, 100 cm (2x)
Air check (2x)
Float (2x)
Grommet, float (4x)
Brine valve with elbow ⅜”, quick -fit connection (2x)
Elbow ½”, compression connection (2x)
Brine well lid Ø10 cm (2x)
Drain hose
Clamp, drain hose (2x)
Air gap with double hose barb
Page 43
Remark
BT/0125
BT/0275
BT/0500
BT/0750
BT/0125
BT/0275
BT/0500, BT/0750 to be cut to length included in item 8 to be ordered per meter
(*)
TECHNICAL DATA - PF-SOF1
Technical specifications:
Model
Resin (ltr) 25
Operating pressure min/max (bar)
Operating temperature min/max (°C)
Electrical connection (V/Hz)
Max. power cons. Simplex/Duplex (VA)
Hydraulic connection inlet/outlet
Hydraulic connection drain
Hydraulic connection brine tank
Pressure tank
(1) Supplied with 24V transformer
10x35 12x48
Performances @ 3 bar operating pressure (2) :
(2) Indicative numbers, performances depending on operating conditions and water quality
Model
Resin (ltr) 25 50
PF-SOF1-SIM / PF-SOF1-ALT / PF-SOF1-PRL
50 75 100
1,4/8,3
2/48
230/50 (1)
12/2x18
1” BSP Male
13 mm hose barb
⅜” compression fitting
13x54 14x65
PF-SOF1-SIM
75 100
Nominal exchange capacity (m³x°f)
Nominal exchange capacity (m³x°d)
Service flow rate @ ∆p 1 bar (m³/hr)
Salt usage per regeneration (kg)
Rinse water usage per regeneration (ltr)
Max. flow to drain (ltr/min)
138
78
3,4
3,8
165
9,8
275
155
3,4
7,5
285
13,2
413
233
3,5
11,3
400
15,1
550
310
3,5
15,0
540
18,9
Model
Resin (ltr)
Nominal exchange capacity (m³x°f)
Nominal exchange capacity (m³x°d)
Service flow rate @ ∆p 1 bar (m³/hr)
Salt usage per regeneration (kg)
Rinse water usage per regeneration (ltr)
Max. flow to drain (ltr/min)
2x25
275
155
3,4
7,5
330
9,8
2x50
550
310
3,4
15,0
570
13,2
PF-SOF1-ALT
2x75
825
465
3,5
22,5
800
15,1
2x100
1.100
620
3,5
30,0
1.080
18,9
Model
Resin (ltr)
Nominal exchange capacity (m³x°f)
Nominal exchange capacity (m³x°d)
Service flow rate @ ∆p 1 bar (m³/hr)
Salt usage per regeneration (kg)
Rinse water usage per regeneration (ltr)
Max. flow to drain (ltr/min)
2x25
275
155
6,7
7,5
330
9,8
2x50
550
310
6,8
15,0
570
13,2
PF-SOF1-PRL
2x75
825
465
7,0
22,5
800
15,1
2x100
1.100
620
7,0
30,0
1.080
18,9
150
16x65
2x150
1.650
930
3,6
45,0
1.560
22,7
2x150
1.650
930
7,2
45,0
1.560
22,7
150
825
465
3,6
22,5
780
22,7
Page 44
Dimensions:
Model
Resin (ltr)
Width (mm) (W)
Depth (mm) (D)
Depth, incl. factory bypass (mm) (D)
Height (mm) (H)
TECHNICAL DATA - PF-SOF1
25
264
282
371
1.059
50
311
311
376
1.394
PF-SOF1-SIM
75
338
338
389
1.560
100
365
365
403
1.836
150
415
415
428
1.833
Model
Resin (ltr)
Width (mm) (W) (1)
Depth (mm) (D)
Height (mm) (H)
(1) Based on 85 mm spacing
2x25
613
405
1.059
2x50
PF-SOF1-ALT / PF-SOF1-PRL
2x75 2x100
707
410
1.394
761
436
1.560
815
463
1.836
2x150
915
513
1.833
Page 45
TECHNICAL DATA - PF-SOF1,5
Technical specifications:
Model
Resin (ltr) 75
PF-SOF1,5-SIM / PF-SOF1,5-ALT / PF-SOF1,5-PRL
100 150 200 250 350
Operating pressure min/max (bar)
Operating temperature min/max (°C)
Electrical connection (V/Hz)
Max. power cons. Simplex/Duplex (VA)
1,4/8,0
2/48
230/50 (1)
80/2x89
1,5 ” BSP Male /Female Hydraulic connection inlet/outlet
Hydraulic connection drain
Hydraulic connection brine tank
Pressure tank
(1) Supplied with 24V transformer
13x54 14x65 16x65
Performances @ 3 bar operating pressure (2) :
(2) Indicative numbers, performances depending on operating conditions and water quality
Model
Resin (ltr) 75 100
1” BSP Male
½” compression fitting
18x65 21x62
150
PF-SOF1,5-SIM
200 250
24x72
Nominal exchange capacity (m³x°f)
Nominal exchange capacity (m³x°d)
Service flow rate @ ∆p 1 bar (m³/hr)
Salt usage per regeneration (kg)
Rinse water usage per regeneration (ltr)
Max. flow to drain (ltr/min)
413
233
7,8
11,3
469
15,2
550
310
7,8
15,0
578
19,0
825
465
7,8
22,5
838
22,7
1.100
620
7,9
30,0
1.148
30,3
1.375
775
7,9
37,5
1.435
37,9
350
1.925
1.085
8,0
52,5
2.140
56,8
Model
Resin (ltr)
Nominal exchange capacity (m³x°f)
Nominal exchange capacity (m³x°d)
Service flow rate @ ∆p 1 bar (m³/hr)
Salt usage per regeneration (kg)
Rinse water usage per regeneration (ltr)
Max. flow to drain (ltr/min)
2x75
825
465
7,8
22,5
938
15,2
2x100
1.100
620
7,8
30,0
1.156
19,0
2x150
PF-SOF1,5-ALT
2x200
1.650
930
2.200
1.240
7,8
45,0
1.676
22,7
7,9
60,0
2.296
30,3
2x250
2.750
1.550
7,9
75,0
2.870
37,9
2x350
3.850
2.170
8,0
105,0
4.280
56,8
Model
Resin (ltr)
Nominal exchange capacity (m³x°f)
Nominal exchange capacity (m³x°d)
Service flow rate @ ∆p 1 bar (m³/hr)
Salt usage per regeneration (kg)
Rinse water usage per regeneration (ltr)
Max. flow to drain (ltr/min)
2x75
825
465
15,6
22,5
938
15,2
2x100
1.100
620
15,6
30,0
1.156
19,0
2x150
PF-SOF1,5-PRL
2x200 2x250
1.650
930
15,6
45,0
1.676
22,7
2.200
1.240
15,8
60,0
2.296
30,3
2.750
1.550
15,8
75,0
2.870
37,9
2x350
3.850
2.170
16,0
105,0
4.280
56,8
500
30x72
2x500
5.500
3.100
16,0
150,0
6.060
75,7
2x500
5.500
3.100
8,0
150,0
6.060
75,7
500
2.750
1.550
8,0
75,0
3.030
75,7
Page 46
Dimensions:
Model
Resin (ltr)
Width (mm) (W)
Depth (mm) (D)
Height (mm) (H)
TECHNICAL DATA - PF-SOF1,5
75
390
575
1.623
100
403
575
1.904
150
428
575
1.901
PF-SOF1,5-SIM
200
491
595
1.952
250
555
627
1.951
350
635
667
2.148
500
786
786
2.066
Resin (ltr)
Width (mm) (W) (1)
Depth (mm) (D)
Height (mm) (H)
(1) Based on 150 mm spacing
Model
2x75
930
690
1.623
2x100
956
690
1.904
PF-SOF1,5-ALT / PF-SOF1,5-PRL
2x150 2x200 2x250
1.006
690
1.901
1.132
706
1.952
1.260
738
1.951
2x350
1.420
778
2.148
2x500
1.722
850
2.066
Page 47
Technical specifications:
Model
Volume (ltr)
Hydraulic connection brine valve
Hydraulic connection overflow
Dimensions:
Model
Volume (ltr)
Diameter (mm) (D)
Height (mm) (H)
Height overflow (mm) (H1)
Max. salt storage capacity (kg)
TECHNICAL DATA - PF-BTA
PF-BTA
125 275 500 750 interchangeable: ⅜” Quick Fit & ½” compression fitting
13 mm hose barb
125
540
850
660
100
275
685
975
825
200
PF-BTA
500
875
1.110
945
475
750
1.030
1.110
945
700
Page 48
Page 49
Page 50
Page 51
Manufactured & Assembled by
erie water treatment
a division of Aquion, Inc.
www.eriewatertreatment.com