Upon receipt of the product and prior to initial operation, read these instructions thoroughly, and retain for future reference.
MOTOMAN INSTRUCTIONS
MOTOMAN-
INSTRUCTIONS
DX100 INSTRUCTIONS
DX100 OPERATOR’S MANUAL
DX100 MAINTENANCE MANUAL
The DX100 operator’s manual above corresponds to specific usage.
Be sure to use the appropriate manual.
Part Number: 156440-CD
Revision: 0
YASKAWA ELECTRIC CORPORATION
MANUAL NO.
HW1480266
1/13
DX100
HW1480266
MANDATORY
• This manual explains the arm interfere check function of the DX100 system. Read this manual carefully and be sure to understand its contents before handling the DX100.
• General Items related to safety are listed in chapter 1 “Safety” of the
Setup Manual. To ensure correct and safe operation, carefully read the Setup manual before reading this manual.
CAUTION
• The drawing in this manual are shown with the protective covers or shields removed for clarity. Be sure all covers and shields are replaced before operating this product.
• The drawing and photos in this manual are representative examples and differences may exist between them and the delivered product.
• YASKAWA may modify this model without notice when necessary due to product improvements, modifications, or changes in specifications.
If such modification is made, the manual number will also be revised.
• If your copy of the manual is damaged or lost, contact a YASKAWA representative to order a new copy. The representatives are listed on the back cover. Be sure to tell the representative the manual number listed on the front cover.
• YASKAWA is not responsible for incidents arising from unauthorized modification of its products. Unauthorized modification voids your product’s warranty.
ii
HW1480266
2/13
HW1480266
DX100
Notes for Safe Operation
Read this manual carefully before installation, operation, maintenance, or inspection of the DX100.
In this manual, the Notes for Safe Operation are classified as
“WARNING”, “CAUTION”, “MANDATORY”, or “PROHIBITED”.
WARNING
CAUTION
Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury to personnel.
Indicates a potentially hazardous situation which, if not avoided, could result in minor or moderate injury to personnel and damage to equipment.
It may also be used alert against unsafe practice.
MANDATORY
Always be sure to follow explicitly the items listed under this heading.
PROHIBITED
Must never be performed.
Even items described as “CAUTION” may result in a serious accident in some situations. At any rate, be sure to follow these important items.
NOTE
To ensure safe and efficient operation at all times, be sure to follow all instructions, even if not designated as
“CAUTION” and “WARNING”.
iii
HW1480266
3/13
DX100
HW1480266
WARNING
• Before operating the manipulator, check that servo power is turned
OFF pressing the emergency stop buttons on the front door of the
DX100 and the programming pendant.
When the servo power is turned OFF, the SERVO ON LED on the programming pendant is turned OFF.
Injury or damage to machinery may result if the emergency stop circuit cannot stop the manipulator during an emergency. The manipulator should not be used if the emergency stop buttons do not function.
Fig. : Emergency Stop Button
• Once the emergency stop button is released, clear the cell of all items which could interfere with the operation of the manipulator.
Then turn the servo power ON.
Injury may result from unintentional or unexpected manipulator motion.
Fig. : Release of Emergency Stop
TURN
• Observe the following precautions when performing teaching operations within the P-point maximum envelope of the manipulator:
– View the manipulator from the front whenever possible.
– Always follow the predetermined operating procedure.
– Keep in mind the emergency response measures against the manipulator’s unexpected motion toward you.
– Ensure that you have a safe place to retreat in case of emergency.
Improper or unintended manipulator operation may result in injury.
• Confirm that no person is present in the P-point maximum envelope of the manipulator and that you are in a safe location before:
– Turning ON the power for the DX100.
– Moving the manipulator with the programming pendant.
– Running the system in the check mode.
– Performing automatic operations.
Injury may result if anyone enters the P-point maximum envelope of the manipulator during operation. Always press an emergency stop button immediately if there is a problem.
The emergency stop buttons are located on the right of front door of the
DX100 and the programming pendant.
iv
HW1480266
4/13
HW1480266
DX100
CAUTION
• Perform the following inspection procedures prior to conducting manipulator teaching. If problems are found, repair them immediately, and be sure that all other necessary processing has been performed.
– Check for problems in manipulator movement.
– Check for damage to insulation and sheathing of external wires.
• Always return the programming pendant to the hook on the cabinet of the DX100 after use.
The programming pendant can be damaged if it is left in the manipulator’s work area, on the floor, or near fixtures.
• Read and understand the Explanation of the Warning Labels in the
Setup manual before operating the manipulator.
Definition of Terms Used Often in This Manual
The MOTOMAN is the YASKAWA industrial robot product.
The MOTOMAN usually consists of the manipulator, the controller, the programming pendant, and supply cables.
In this manual, the equipment is designated as follows:
Equipment
DX100 controller
DX100 programming pendant
Cable between manipulator and DX100
Manual Designation
DX100
Programming pendant
Manipulator cables v
HW1480266
5/13
HW1480266
DX100
Descriptions of the programming pendant, buttons, and displays are shown as follows:
Equipment
Programming pendant
Manual Designation
Character Keys The keys which have characters printed on them are denoted with [ ].
ex. [ENTER]
Symbol Keys The keys which have a symbol printed on them are not denoted with [ ] but depicted with a small picture.
Axis Keys
Number Keys
Keys pressed simultaneously
Displays ex. page key
The cursor key is an exception, and a picture is not shown.
“Axis Keys” and “Number Keys” are generic names for the keys for axis operation and number input.
When two keys are to be pressed simultaneously, the keys are shown with a
“+” sign between them, ex. [SHIFT] +
[COORD]
The menu displayed in the programming pendant is denoted with { }.
ex. {JOB}
Description of the Operation Procedure
In the explanation of the operation procedure, the expression “Select • • •” means that the cursor is moved to the object item and the SELECT key is pressed, or that the item is directly selected by touching the screen.
Registered Trademark
In this manual, names of companies, corporations, or products are trademarks, registered trademarks, or brand names for each company or corporation. The indications of (R) and TM are omitted.
vi
HW1480266
6/13
HW1480266
DX100 Contents
1.4 Alarm/Error ........................................................................................................................ 1-5
1.4.1 Axis Operation ...................................................................................................... 1-5
1.4.2 PLAYBACK/FWD/BWD/TEST Operation ............................................................. 1-5
1.5 Notes ................................................................................................................................. 1-5 vii
HW1480266
7/13
HW1480266
DX100
1 Arm Interfere Check Function
1.1
Outline of Arm Interfere Check Function
1 Arm Interfere Check Function
1.1
Outline of Arm Interfere Check Function
This function checks the interference among robot arms and tools in the system consisting of one controller and multiple robots.
Interference between each of the following is checked:
(1) An arm and an arm
(2) An arm and a tool
(3) A tool and a tool
The checking method is to approximate each axis arm and tool in cylinder and then the interference is checked between the approximated cylinders.
Spheres are set at both ends of the cylinder, and the interferences are checked between spheres and between sphere and cylinder.
If this cylinder or sphere is intersected, the robot stops.
1-1
HW1480266
8/13
HW1480266
DX100
1 Arm Interfere Check Function
1.2
Setting of Arm Interfere Check Function
1.2
Setting of Arm Interfere Check Function
The arm interfere check function requires setting of cylinder and sphere for the robot arm. These setting values need not be set by the customer because they are factory-set.
The tool part must be set by the customer because the tool shape depends on the work that the robot performs. These settings are set in the tool interfere file.
The tool interfere file is shown by using the procedure to select {TOP
MENU} → {ROBOT} → {TOOL INTERFERE}.
• A maximum of 64 tool interfere files can be set.
In accordance with the tool number specified in operation, one file is selected out of 64 files.
• A maximum of 5 cylinders and spheres can be set.
1 to 5 points can be set by moving the cursor below.
• Point 1 and Point 2 set both end positions that set the cylinder.
Like the setting of the tool dimensions, the setting values are set with the center of T-axis flange regarded as the starting point (X=0, Y=0,
Z=0).
• Radius sets the radius of the cylinder and sphere between Point 1 and Point 2. The sphere is set for Point 1 and Point 2.
1-2
HW1480266
9/13
HW1480266
DX100
1 Arm Interfere Check Function
1.2
Setting of Arm Interfere Check Function
1.2.2 Release of Arm Interfere Check
The release of the arm interfere check can be set in the limit release screen.
The limit release screen is shown by using the procedure to select {TOP
MENU} → {ROBOT} → {LIMIT RELEASE}.
When the cursor is moved to {INVALID} of the arm interfere check release and the {SELECT} key is pressed, {INVALID} is changed to {VALID} or
{VALID} is changed to {INVALID}.
Setting {INVALID} invalidates the arm interfere check release and checks the arm interfere.
Setting {VALID} validates the arm interfere check release and does not check the arm interfere.
1.2.3 Calibration between Manipulators (Robots)
To use this function, perform the calibration between manipulators. For the procedure of the calibration between manipulators, refer to “DX100
Independent/Coordinated Control Function Instructions (R-CHI-A454),
Chapter 3 Jigless System, 3.5 System Setup”.
1-3
HW1480266
10/13
HW1480266
DX100
1 Arm Interfere Check Function
1.3
Example of Setting Tool Interfere File
1.3
Example of Setting Tool Interfere File
Tool coordinate origin position
(T-axis flange face)
1 Point1
140
2 Point1
1 Point2
* No offset shall be set in Y direction.
3 Point2
2 Point2
3 Point1
1-4
HW1480266
11/13
DX100
HW1480266
1 Arm Interfere Check Function
1.4
Alarm/Error
1.4
Alarm/Error
If the arm (tool) interference occurs during the axis operation, “ARM
(TOOL) INTERFERE” is shown in the message line and the manipulators stop.
In this case, perform the axis operation in the direction with no arm interfere. If the axis operation is not allowed in the direction with no arm interfere in this case, temporally invalidate the arm interfere check as described in chapter 1.2.2 “Release of Arm Interfere Check” at page 1-3
.
If the arm (tool) interfere occurs in PLAYBACK/FWD/BWD/TEST operation, “Alarm 4620 ARM (TOOL) INTERFERE” is issued and the manipulators stop.
In this case, perform the axis operation to move to the position with no arm interfere.
If the arm interfere occurs during playback, review the job to prevent the arm interfere.
1.5
Notes
(1) About accuracy of arm (tool) interfere check
The robot accuracy has an error due to the calibration accuracy between robots or a delay in the servo system.
Therefore, set the radius of the tool interfere file with an allowance.
(2) Determine the setting value of the TOOL INTERFERE file in accordance with the drawing.
(3) The arm interfere check function may not be used depending on the robot type.
Contact a YASKAWA representative nearest you.
1-5
HW1480266
12/13
DX100 OPTIONS
INSTRUCTIONS
ARM INTERFERE CHECK FUNCTION OPERATING INSTRUCTIONS
HEAD OFFICE
2-1 Kurosaki-Shiroishi, Yahatanishi-ku, Kitakyusyu, Fukuoka, 806-0004, Japan
Phone +81-93-645-7745 Fax +81-93-645-7746
YASKAWA America Inc. MOTOMAN Robotics Division
805 Liberty Lane, West Carrollton, OH 45449, U.S.A.
Phone +1-937-847-6200 Fax +1-937-847-6277
YASKAWA Nordic AB
Franska vagen 10, Box 4004, 390 04 Kalmar, Sweden
Phone +46-480-417800 Fax +46-480-417999
YASKAWA Europe GmbH Robotics Division
Kammerfeld strasse 1, 85391 Allershausen, Germany
Phone +49-8166-90-100 Fax +49-8166-90-103
YASKAWA Electric Korea Co., Ltd.
7F, Doore Bldg.; 24, Yeoido-Dong Youngdungpo-ku, Seoul, KOREA
Phone +82-2-784-7844 Fax +82-2-784-8495
YASKAWA Electric (Singapore) PTE Ltd.
151 Lorong Chuan, #04-02A, New Tech Park, Singapore 556741
Phone +65-6282-3003 Fax +65-6289-3003
YASKAWA Electric (Thailand) Co., Ltd.
252/246, 4th Floor. Muang Thai-Phatra Office Tower II Rachadaphisek Road, Huaykwang Bangkok, 10320 Thailand
Phone +66-2-693-2200 Fax +66-2-693-4200
Shougang MOTOMAN Robot Co. Ltd.
No.7, Yongchang-North Road, Beijing E&T Development Area, China 100176
Phone +86-10-6788-2858 Fax +86-10-6788-2878
MOTOMAN Motherson Robotics Ltd.
Plot No.195-196, 1st Floor, Sec.4 IMT Manesar, Gurgaon 122050, Haryana
Phone +91-124-475-8500 Fax +91-124-414-8016
Specifications are subject to change without notice for ongoing product modifications and improvements.
YASKAWA ELECTRIC CORPORATION
C Printed in Japan March 2011 11-03
MANUAL NO.
HW1480266
13/13
Download
Advertisement