SPLIT SYSTEM HEAT PUMP 14 SEER INSTALLATION INSTRUCTIONS *SH(1,2)BE4M1 - SP18K, (R,S)P24K, (R,S)P30K, SP36K, SP42K, SP48K, & SP60KA (1.5, 2, 2.5, 3, 3.5, 4, & 5 TON) SERIES, SINGLE PHASE MODELS WITH MICROCHANNEL COILS IMPORTANT ATTENTION INSTALLERS: It is your responsibility to know this product better than your customer. This includes being able to install the product according to strict safety guidelines and instructing the customer on how to operate and maintain the equipment for the life of the product. Safety should always be the deciding factor when installing this product and using common sense plays an important role as well. Pay attention to all safety warnings and any other special notes highlighted in the manual. Improper installation of the unit or failure to follow safety warnings could result in serious injury, death, or property damage. These instructions are primarily intended to assist qualified individuals experienced in the proper installation of this appliance. Some local codes require licensed installation/service personnel for this type of equipment. Please read all instructions carefully before starting the installation. Return these instructions to the customer’s package for future reference. DO NOT DESTROY. PLEASE READ CAREFULLY & KEEP IN A SAFE PLACE FOR FUTURE REFERENCE. IMPORTANT SAFETY INFORMATION........................... 2 HEAT PUMP INSTALLATION......................................... 3 General Information................................................................... 3 Before You Install the Heat Pump.............................................. 3 Locating the Heat Pump............................................................ 3 Packaging Removal................................................................... 3 Ground Level............................................................................. 3 Rooftop...................................................................................... 3 Connecting Refrigerant Tubing Between the Indoor & Outdoor Unit.............................................................................. 4 Outdoor Orifice Removal & Installation...................................... 4 ELECTRICAL WIRING.................................................... 5 Pre-Electrical Checklist.............................................................. 5 Line Voltage............................................................................... 5 Grounding.................................................................................. 5 Thermostat / Low Voltage Connections..................................... 5 CoreSenseTM Diagnostics Module............................................. 6 Compressor Protection........................................................... 6 Resetting Alert Codes............................................................. 6 START UP & ADJUSTMENTS........................................ 7 Pre-Start Check List.................................................................. 7 Start-Up Procedures.................................................................. 7 Operating Temperatures............................................................ 7 Air Circulation - Indoor Blower................................................... 7 Short Cycle Protection............................................................... 7 System Cooling.......................................................................... 7 System Heating......................................................................... 7 Defrost Control Board Test Pins................................................. 7 HEAT PUMP MAINTENANCE......................................... 8 Panel Removal........................................................................... 8 Panel Installation....................................................................... 8 REFRIGERANT CHARGING........................................... 9 Charging the Unit in AC mode................................................... 9 If the outdoor temperature is 65 degrees F or higher:............ 9 If the outdoor temperature is between 35 degrees F an 65 degrees F:.......................................................................... 9 If the outdoor temperature is below 35 degrees F:................. 10 WIRING DIAGRAMS........................................................ 11 Figure 9. Wiring Diagram for *SH(1,2)BE4M1SP (1.5 Ton - 4 Ton)...................................................... 11 Figure 10. Wiring Diagram for *SH(1,2)BE4M1SP60K (5 Ton)................................................................... 12 Figure 11. Wiring Diagram for *SH1BE4M1SP (1.5 - 4 Ton).. 13 Figure 12. Wiring Diagram for *SH1BE4M1SP60KA (5 Ton). 14 Figure 13. Wiring Diagram for *SH1BE4M1SP with Low Pressure Switch (Manufactured Housing)............. 15 Figure 14. Wiring Diagram for *SH2BE4M1RP (Manufactured Housing)........................................ 16 Figure 15. Wiring Diagram for *SH2BE4M1SP (Manufactured Housing)........................................ 17 Figure 16. Wiring Diagram for *SH2BE4M1RP (Builder's Series).................................................... 18 Figure 17. Wiring Diagram for *SH2BE4M1SP (1 - 4 Ton)..... 19 Figure 18. Wiring Diagram for *SH2BE4M1SP (5 Ton).......... 20 INSTALLATION CHECKLIST.......................................... 24 REPLACEMENT PARTS................................................. 24 IMPORTANT SAFETY INFORMATION INSTALLER: Please read all instructions before servicing this equipment. Pay attention to all safety warnings and any other special notes highlighted in the manual. Safety markings are used frequently throughout this manual to designate a degree or level of seriousness and should not be ignored. WARNING indicates a potentially hazardous situation that if not avoided, could result in personal injury or death. CAUTION indicates a potentially hazardous situation that if not avoided, may result in minor or moderate injury or property damage. WARNING: ELECTRICAL SHOCK, FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result in serious injury or property damage. Improper servicing could result in dangerous operation, serious injury, death or property damage. • Before servicing, disconnect all electrical power to the unit. • When servicing controls, label all wires prior to disconnecting. Reconnect wires correctly. • Verify proper operation after servicing. WARNING: This split system heat pumps is shipped charged with R410A refrigerant and ready for installation. If repairs make it necessary for evacuation and charging, it should only be attempted by qualified trained personnel thoroughly familiar with this equipment. Under no circumstances should the owner attempt to install and/or service this equipment. Failure to comply with this warning could result in property damage, personal injury, or death. CAUTION: This unit uses R-410A refrigerant. DO NOT use any other refrigerant in this unit. Use of another refrigerant will damage the unit. 2 WARNING: Unless noted otherwise in these instructions, only factory authorized parts or accessory kits may be used with this product. Improper installation, service, adjustment, or maintenance may cause explosion, fire, electrical shock or other hazardous conditions which may result in personal injury or property damage. • Installation of equipment may require brazing operations. Installer must comply with safety codes and wear appropriate safety equipment (safety glasses, work gloves, fire extinguisher, etc.) when performing brazing operations. • Follow all precautions in the literature, on tags, and on labels provided with the equipment. Read and thoroughly understand the instructions provided with the equipment prior to performing the installation and operational checkout of the equipment. • Use caution when handling this appliance or removing components. Personal injury can occur from sharp metal edges present in all sheet metal constructed equipment. WARNING: The information listed below and the next page must be followed during the installation, service, and operation of this equipment. Failure to follow safety recommendations could result in possible damage to the equipment, serious personal injury or death. • The installer must comply with all local codes and regulations which govern the installation of this type of equipment. Local codes and regulations take precedence over any recommendations contained in these instructions. Consult local building codes and the National Electrical Code (ANSI CI) for special installation requirements. • All electrical wiring must be completed in accordance with local, state and national codes and regulations and with the National Electric Code (ANSI/NFPA 70) or in Canada the Canadian Electric Code Part 1 CSA C.22.1. • This equipment contains liquid and gaseous refrigerant under high pressure. DO NOT USE ANY PORTION OF THE CHARGE FOR PURGING OR LEAK TESTING. Installation or servicing should only be performed by qualified trained personnel thoroughly familiar with this type equipment. • Fully annealed, refrigerant grade copper tubing should be used when installing the system. Refrigerant suction line tubing should be fully insulated. • This unit is designed for outdoor installations only and should be positioned as shown on page 3. HEAT PUMP INSTALLATION General Information *SH(1,2)BE4M1 split system heat pumps are designed only for outdoor rooftop or ground level installations. This unit has been tested for capacity and efficiency in accordance with AHRI Standards and will provide many years of safe and dependable comfort, providing it is properly installed and maintained. Abuse, improper use, and/or improper maintenance can shorten the life of the appliance and create unsafe hazards. To achieve optimum performance and minimize equipment failure, it is recommended that periodic maintenance be performed on this unit. The ability to properly perform maintenance on this equipment requires certain mechanical skills and tools. Refer to the Quick Reference Data sheet for additional electrical, charging and unit information. Before You Install the Heat Pump √ The cooling load of the area to be conditioned must be calculated and a system of the proper capacity selected. It is recommended that the area to be conditioned be completely insulated and vapor sealed. √ Check the electrical supply and verify the power supply is adequate for unit operation. The system must be wired and provided with circuit protection in accordance with local building codes. If there is any question concerning the power supply, contact the local power company. √ The indoor section (air handler, furnace, etc) should be installed before routing the refrigerant tubing. Refer to the indoor unit's installation instructions for installation details. √ All units are securely packed at the time of shipment and upon arrival should be carefully inspected for damage prior to installing the equipment at the job site. Verify coil fins are straight. If necessary, comb fins to remove flattened or bent fins. Claims for damage (apparent or concealed) should be filed immediately with the carrier. √ Please consult your dealer for maintenance information and availability of maintenance contracts. Please read all instructions before installing the unit. Packaging Removal To prevent damage to the tubing onnections, carefully remove the carton and user’s manual from the equipment. Discard the shipping carton. Ground Level Ground level installations must be located according to local building codes or ordinances and these requirements: • Clearances must be in accordance with those shown in Figure 1. • A suitable mounting pad must be provided and be separate from the building foundation. The pad must be level and strong enough to support the unit’s weight. The slab height must be a minimum of 2” (5 cm) above grade and with adequate drainage. See Figure 1. Rooftop • The method of mounting should be designed so that it does not overload roof structures or transmit noise to the interior of the structure. The roof must be structurally capable of handling the weight of the unit. • Full perimeter support is required under the unit. Support must be made of weather resistant materials and installed prior to unit installation. • The support must be built to raise the unit 6" above the roof. 6” from Building or Structure 24" for Service Access 12" or 18” See Note DO NOT OBSTRUCT TOP OF UNIT 12" or 18” See Note NOTE: Units require full perimeter clearances. Installer must maintain 18” between two units or 12” between single unit and structure. Locating the Heat Pump • Survey the job site to determine the best location for mounting the outdoor unit. • Overhead obstructions, poorly ventilated areas, and areas subject to accumulation of debris should be avoided. See Figure 1. • Sufficient clearance for unobstructed airflow through the outdoor coil must be maintained in order to achieve rated performance. See Figure 1 for minimum clearances to obstructions. • Consideration should be given to availability of electric power, service access, noise, and shade. 48” 2” Mounting Pad Figure 1. Clearance Requirements 3 Connecting Refrigerant Tubing Between the Indoor & Outdoor Unit CAUTION: When servicing, cover or seal openings to minimize the exposure of the refrigerant system to air to prevent accumulation of moisture and other contaminants. After outdoor and indoor unit placement has been determined, route refrigerant tubing between the equipment in accordance with sound installation practices. • When connecting refrigerant linesets together, it is recommended that dry nitrogen be flowing through the joints during brazing. This will prevent internal oxidation and scaling from occurring. • Refrigerant tubing should be routed in a manner that minimizes the length of tubing and the number of bends in the tubing. • Refrigerant tubing should be supported in a manner that the tubing will not vibrate or abrade during system operation. • Tubing should be kept clean of foreign debris during installation. • Every effort should be made by the installer to ensure that the field installed refrigerant containing components of the system have been installed in accordance with these instructions and sound installation practices to insure reliable system operation and longevity. • The maximum recommended interconnecting refrigerant line length is 75 feet, and the vertical elevation difference between the indoor and outdoor sections should not exceed 20 feet. • If precise forming of refrigerant lines is required, a copper tubing bender is recommended. Avoid sharp bends and contact of the refrigerant lines with metal surfaces. • A filter dryer is provided with the unit and must be installed in the liquid line of the system. If the installation replaces a system with a filter dryer already present in the liquid line, the filter dryer must be replaced with the one supplied with the unit. The filter dryer must be installed in strict accordance with the manufacturer’s installation instructions. • Optional equipment such as liquid line solenoid valves, low ambient, etc., should be installed in strict accordance with the manufacturer’s installation instructions. Outdoor Orifice Removal & Installation CAUTION: When servicing, cover or seal openings to minimize the exposure of the refrigerant system to air to prevent accumulation of moisture and other contaminants. CAUTION: To prevent damage to the unit or internal components, it is recommended that two wrenches be used when loosening or tightening nuts. Do not over tighten! 1. Using two wrenches loosen the nut and liquid valve. Turn the assembly nut counter-clockwise until the orifice body halves are separated. 2. Insert a light-gauge wire hook between the valve body and the restrictor orifice while being careful not to scratch either part. Carefully remove the restrictor orifice from the valve body. See Figure 3. Liquid Valve Restrictor Swivel Nut Figure 2. Liquid Valve, Restrictor, & Swivel Nut Adapter The orifice installed in the outdoor unit has been sized for use with the most popularly matched indoor units. Depending on the indoor coil that the unit is being matched with, the outdoor restrictor may need to be changed. Please refer to the Quick Reference Data sheet that is supplied with the outdoor unit for more information. If the outdoor unit has the liquid valve shown in Figure 2, then the restrictor is located inside the swivel nut connection of the liquid valve and not inside the outdoor unit’s distributor. Perform steps 1 - 5 if the outdoor restrictor needs to be changed. Figure 3. Removal of Orifice 4 3. Check the actual size of the new orifice. NOTE: The size is stamped on its side. Do not use pin gauges to measure the orifice diameter. 4. Insert the new orifice into the valve body, with the rounded end facing into the valve. See Figure 2 (page 4). CAUTION: • To prevent damage to the unit or internal components, it is recommended that two wrenches be used when loosening or tightening nuts. Do not over tighten! 5. Realign the assembly nut on the valve body and hand tighten both components. Mark a line on both bodies and then tighten an additional ¼ turn using two wrenches. The movement of the two lines will show how much the nut is tightened. ELECTRICAL WIRING WARNING: To avoid risk of electrical shock, personal injury, or death, disconnect all electrical power to the unit before performing any maintenance or service. The unit may have more than one electrical supply. Label all wires prior to disconnection when servicing the unit. Wiring errors can cause improper and dangerous operation. • All electrical connections must be in compliance with all applicable local codes and ordinances, and with the current revision of the National Electric Code (ANSI/NFPA 70). • For Canadian installations the electrical connections and grounding shall comply with the current Canadian Electrical Code (CSA C22.1 and/or local codes). Pre-Electrical Checklist √ Verify that the voltage, frequency, and phase of the supply source match the specifications on the unit rating plate. √ Verify that the service provided by the utility is sufficient to handle the additional load imposed by this equipment. Refer to the unit wiring label for proper high and low voltage wiring. √ Verify factory wiring is in accordance with the unit wiring diagram. Inspect for loose connections. See Figure 9 (page 11), Figure 10 (page 12), Figure 11 (page 13)) Figure 12 (page 14), Figure 13 (page 15), Figure 14 (page 16), Figure 15 (page 17), Figure 16 (page 18), Figure 17 (page 19), & Figure 18 (page 20). Line Voltage • A wiring diagram is located on the inside cover of the electrical box of the outdoor unit. The installer should become familiar with the wiring diagram before making any electrical connections to the outdoor unit. • An electrical disconnect must be located within sight of and readily accessible to the unit. This switch shall be capable of electrically de-energizing the outdoor unit. • Line voltage to the unit should be supplied from a dedicated • • • • • branch circuit containing the correct fuse or circuit breaker for the unit. Incoming field wiring and minimum size of electrical conductors and circuit protection must be in compliance with information listed on the outdoor unit data label. Any other wiring methods must be acceptable to authority having jurisdiction. The outdoor unit requires both power and control circuit electrical connections. Refer to the wiring diagrams for identification and location of outdoor unit field wiring interfaces. See Figure 9 (page 11), Figure 10 (page 12), Figure 11 (page 13)) Figure 12 (page 14), Figure 13 (page 15), Figure 14 (page 16), Figure 15 (page 17), Figure 16 (page 18), Figure 17 (page 19), & Figure 18 (page 20). Make all electrical connections in accordance with all applicable codes and ordinances. Overcurrent protection must be provided at the branch circuit distribution panel and sized as shown on the unit rating label and according to applicable local codes. See the unit rating plate for minimum circuit ampacity and maximum overcurrent protection limits. Provide power supply for the unit in accordance with the unit wiring diagram, and the unit rating plate. Connect the line-voltage leads to the terminals on the contactor inside the control compartment. Use only copper wire for the line voltage power supply to this unit in strict accordance of the NEC (ANSI/NFPA 70), applicable local codes, and the instructions provided with the equipment. Use proper code agency listed conduit and a conduit connector for connecting the supply wires to the unit. Use of rain tight conduit is recommended. 208/230 Volt units are shipped from the factory wired for 230 volt operation. For 208V operation, remove the lead from the transformer terminal marked 240V and connect it to the terminal marked 208V. Optional equipment requiring connection to the power or control circuits must be wired in strict accordance of the NEC (ANSI/NFPA 70), applicable local codes, and the instructions provided with the equipment. Grounding WARNING: The unit cabinet must have an uninterrupted or unbroken electrical ground to minimize personal injury if an electrical fault should occur. Do not use gas piping as an electrical ground! This unit must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code (ANSI/NFPA 70) or the CSA C22.1 Electrical Code. Use the grounding lug provided in the control box for grounding the unit. Thermostat / Low Voltage Connections • Thermostat connections should be made in accordance with the instructions supplied with the thermostat and the indoor equipment. A typical installation with a heat pump thermostat and air handler is shown in Figure 4 (page 6). • The outdoor unit is designed to operate from a 24 VAC Class II control circuit. The control circuit wiring must comply with the current provisions of the NEC (ANSI/NFPA 70) and with applicable local codes having jurisdiction. 5 ODT (Optional) W2 IN G Green G Red R R W2 OUT W C C O O O Y1 IN Y Y Outdoor Heat Pump R White E Black C Thermostat W2 • The low voltage wires must be properly connected to the units low voltage terminal block. • The thermostat should be mounted about 5 feet above the floor on an inside wall. DO NOT install the thermostat on an outside wall or any other location where its operation may be adversely affected by radiant heat from fireplaces, sunlight, or lighting fixtures, and convective heat from warm air registers or electrical appliances. Refer to the thermostat manufacturer’s instruction sheet for detailed mounting and installation information. CoreSenseTM Diagnostics Module (Select Models Only) The CoreSenseTM Diagnostics Module, Figure 5, is a breakthrough innovation for troubleshooting heat pump and air conditioning system failures. The module installs easily in the electrical box of the outdoor unit near the compressor contactor.By using the compressor as a sensor, CoreSense Diagnostics helps the service technician more accurately troubleshoot system and compressor fault conditions. Air Handler A flashing LED indicator communicates the ALERT code and a diagnostic key is also imprinted on the side of the module to quickly direct the technician to the root cause of a problem. Alert identification codes are also listed in Table 1. Figure 4. Typical Thermostat Connections Compressor Common Wire Reset Button Run / Alert (Yellow LED) The CoreSenseTM Diagnostics module utilizes proprietary algorithms to protect the compressor and system from repeated trips of system pressure controls and the compressor internal overload. The protection terminal of the module should be wired in series with the system low pressure and high pressure cutouts, as well as the compressor contactor. When the module detects a series of trips as described below, it will activate a lockout feature that opens the normally closed protection contacts in the module, thereby cutting power to the contactor and shutting off the compressor. Resetting Alert Codes When the CoreSenseTM Diagnostics module has detected a series of adverse conditions that have caused it to lockout the compressor, and after the issue has been resolved, it is necessary to manually reset the module in order to clear the present alert code. Trip / Lock (Red LED) Figure 5. CoreSenseTM Diagnostics Module ALERT CODE Compressor Protection The primary way of clearing the code and resetting the alert is to press the reset button located on the module. LOCK LEVEL LOCK INDICATION Normal operation, no trip N/A N/A Code1 Yellow Flash 1 Long run time. Compressor is on running for more than 18 hours. (Code1 is disabled in Heat Pump Mode) N/A N/A Code2 Yellow Flash 2 Compressor (pressure) trip. Compressor runs for 12 sec to 15 min followed by a compressor trip condition lasting for more than 7 min. 4x consecutive Red: Flash2 Yellow: Off Code3 Yellow Flash 3 Pressure switch cycling. Compressor runs for 12 sec to 15 min followed by a compressor trip lasting between 35 sec to 7 min. 4x consecutive or 10x total Red: Flash3 Yellow: Off Code4 Yellow Flash 4 Locked rotor. Compressor trips within a compressor run time of 12 sec and does not start within 35 sec. 10x consecutive Red: Flash4 Yellow: Off Code5 Yellow Flash 5 Compressor (moderate run) trip. Compressor runs for 15 min to 18 hrs followed by a compressor trip lasting longer than 7 min. 4x consecutive or 10x total Red: Flash5 Yellow: Off Current >2A for 40ms Red: Flash9 Yellow: Off N/A N/A Normal Run Solid Yellow Code9 Red Flash 9 Trip Solid Red ALERT CONDITION The current to the PROT terminal is greater than 2A. Demand is present, but compressor is not running. Table 1. LED Diagnostics for CoreSenseTM Diagnostics Module 6 NOTE: Pressing the reset will require a pin or a mini electronics screwdriver. This button must be pressed and held for a minimum of one second for the module to be reset. Pressing the reset button clears the immediate lock code and the seven day operating history. It will not clear the permanent module history. In the case of the three-wire module, the codes can be reset or cleared by cycling power to the module. This can be done by disengaging the Common (C) terminal. This will not clear the seven day operating history. START UP & ADJUSTMENTS Pre-Start Check List √ Verify the unit is level and has sufficient clearances for unobstructed airflow. √ Verify the outdoor coil and top of the unit are free from obstructions and debris, and all equipment access/control panels are in place. √ Verify that the line voltage power leads are securely connected and the unit is properly grounded. √ Verify that the low voltage wires are securely connected to the correct leads on the low voltage terminal strip. √ Verify that the power supply branch circuit overcurrent protection is sized properly. √ Verify that the thermostat is wired correctly. Start-Up Procedures WARNING: This unit is equipped with a crankcase heater. Allow 24 hours prior to continuing the start up procedures to allow for heating of the refrigerant compressor crankcase. Failure to comply may result in damage and could cause premature failure of the system. This warning should be followed at initial start up and any time the power has been removed for 12 hours or longer. Operating Temperatures This equipment has been designed to operate within the temperatures specified in Table 2. Running the equipment in heating at higher than 70°F may require the use of a Heat Pump Mild Weather Control Kit or changing over to emergency or auxiliary heating. Air Circulation - Indoor Blower 1. Set the thermostat system mode on OFF and the fan mode to ON. 2. Verify the blower runs continuously. Check the air delivery at the supply registers and adjust register openings for balanced air distribution. If insufficient air is detected, examine ductwork for leaks or obstructions. 3. Set the thermostat fan mode to AUTO and verify the blower stops running. Short Cycle Protection 1. Set the thermostat system mode to COOL. Observe the temperature setting of the thermostat and gradually raise the set-point temperature until the unit de-energizes. 2. Immediately lower the set point temperature of the thermostat to its original setting and verify that the indoor blower is energized and outdoor unit remains de-energized. 3. After approximately 5 minutes, verify the outdoor unit energizes and the temperature of the discharge air is cooler than the room temperature. COOLING HEATING MIN (°F) MAX (°F) MIN (°F) MAX (°F) 60 115 -10 70 Table 2. Heat Pump Operating Temperatures System Cooling 1. Set the thermostat’s system mode to COOL and the fan mode to AUTO. Gradually lower the thermostat temperature setpoint below room temperature and verify the outdoor unit and indoor blower energize. 2. Verify blower wheel is spinning in direction indicated by arrow. Feel the air being circulated by the indoor blower and verify that it is cooler than ambient temperature. Listen for any unusual noises. If unusual sounds occur, determine the source of the noise and correct as necessary. 3. Verify HI and LO refrigerant pressures. 4. Allow the system to operate for several minutes and then set the temperature selector above room temperature. Verify the fan and compressor cycle off with the thermostat. NOTE: The blower should also stop unless fan switch is set to the ON position. System Heating 1. Set the thermostat's system mode to HEAT and the temperature mode to below room temperature. 2. Verify the outdoor unit and indoor fan stop running. After 5 minutes, increase the temperature on the thermostat to it's maximum setting. 3. Verify the outdoor unit and indoor blower energize. Feel the air being circulated by the indoor blower and verify that it is warmer than ambient temperature. Listen for any unusual noises. If unusual sounds occur, determine the source of the noise and correct as necessary. Defrost Control Board Test Pins • Verify the Status Indicator (on the control board) against the codes listed in Table 3 (page 8) to determine proper diagnostic description. • Terminals ‘R’ and ‘C’ must have 18-30 VAC present between them for proper board operation. • Board anti-short cycle timer can be bypassed by shorting the test terminals for less than 1 second while there is a call for heating or cooling. • Forced defrost enabled when shorting the test terminals for more than three seconds while there is a call for heating or cooling. After short removed, defrost mode will be terminated when conditions are met. • Forced defrost can be maintained for up to 11 minutes by continuously maintaining the short across the test terminals. If held for over 11 minutes, the unit will stop and a flashing ‘dF’ will be indicated on the board. • A continuous display of a fault code will indicate that the fault is still active. • A flashing fault code indicates that the fault has been corrected but remains in memory for troubleshooting purposes. • Multiple fault codes are listed in order from the most recent to the oldest. Only ten codes will be stored in memory. • Faults will remain in the board memory for seven days after the last fault is corrected. • Faults can be cleared from memory by shorting the test terminal momentarily while there is not a call for heating or cooling. 7 STATUS INDICATOR STATUS TYPE C1 C2 H1 H2 SC OF _. 01 02 03 04 05 Operating Status Cooling, 1st Stage Operating Status Cooling, 2nd Stage Operating Status Heating, 1st Stage Operating Status Heating, 2nd Stage Operating Status Anti Short Cycle Timer Operating Status Defrost OF Operating Status (FLASHING) DIAGNOSTIC DESCRIPTION Power on, no call for operation Fault Pressure switch, low Fault Pressure switch, high Fault Temperature Sensor, Ambient Fault Temperature Sensor, Coil Fault Board Input Error Panel Removal 1. Remove screws securing the panel. 2. Slide the panel up towards the top pan in order to clear the bottom flange from the base pan. See Figure 6. 3. Swing the bottom of the panel out and pull the panel down to remove it from the unit. Panel Installation 1. Insert the top corners of side panel flanges into the corner post channels as shown in Detail A in Figure 7. 2. Slide the panel up into the top pan. (You may need to push on the center of the panel at the top in order to clear the top pan edge). 3. Swing the panel in and push down until the panel is resting on the top edge of the base pan wall as shown in Detail B. 4. Insert screws into the panel to secure it to the unit. Forced defrost - test short applied longer than 11 minutes Table 3. Defrost Control Board Status Indicators HEAT PUMP MAINTENANCE WARNING: To prevent electrical shock, personal injury, or death, disconnect all electrical power to the unit before performing any maintenance or service. The unit may have more than one electrical supply. Proper maintenance is important to achieve optimum performance from the heat pump. The ability to properly perform maintenance on this equipment requires certain mechanical skills and tools. If you do not possess these skills, contact your dealer for maintenance. Consult your local dealer about the availability of maintenance contracts. Routine maintenance should include the following: • Inspect and clean or replace air filters at the beginning of each heating and cooling season, or more frequently if required. • Inspect the outdoor coil at the beginning of each cooling season. Remove any debris. Clean the outdoor coil and louvers as necessary using a mild detergent and water. Rinse thoroughly with water. • Inspect the electrical connections for tightness at the beginning of each heating and cooling season. Service as necessary. CAUTION: Figure 6. Panel Removal DETAIL A DETAIL B The unit should never be operated without a filter in the return air system. Replace disposable filters with the same type and size. • Do not add additional oil to motors unequipped with oil tubes. The compressor is hermetically sealed at the factory and does not require lubrication. • To access the internal components of the unit, refer to Figure 6 for panel removal and Figure 7 for panel installation. 8 Figure 7. Panel Installation REFRIGERANT CHARGING WARNING: This split system heat pump is shipped charged with R410A refrigerant and ready for installation. If repairs make it necessary for evacuation and charging, it should only be attempted by qualified trained personnel thoroughly familiar with this equipment. Under no circumstances should the owner attempt to install and/or service this equipment. Failure to comply with this warning could result in property damage, personal injury, or death. After refrigerant line connections are completed, it is required that you leak check and evacuate the indoor section and all line connections (using proper methods) before finalizing the full system refrigerant charge. • To achieve rated capacity and efficiency, the compressor must be exposed to refrigerant for at least 24 hours prior to running and then the compressor must be run for a minimum of 12 hours. • Refer to the Quick Reference Data sheet for additional charging information. Outdoor units with non-AHRI listed indoor coils are not recommended and deviations from rated airflows or non-listed combinations may require modification to the expansion device and refrigerant charging procedures for proper and efficient system operation. • The refrigerant charge can be checked and adjusted through the service ports provided external to the outdoor unit. Use only gage line sets which have a “Schrader” depression device present to actuate the valve. A common suction port for heating mode charging is included and located on the compressor access panel above the outdoor unit service valves. • A high-pressure switch is factory-installed and located in the compressor discharge line internal to the outdoor unit. The switch is designed to de-energize the system when very high pressures occur during abnormal conditions. Under normal conditions, the switch is closed. If the discharge pressure rises above 575 psig, then the switch will open and de-energize the outdoor unit. The switch will close again once the liquid pressure decreases to 460 psig. Please note that the switch interrupts the thermostat inputs to the unit. When the switch opens and then closes, there will be a 5 minute short cycling delay before the outdoor unit will energize. • A low-pressure switch is factory installed (certain models) and located internally on the suction line of the outdoor unit. The switch is designed to protect the compressor from a loss of charge by interrupting the thermostat inputs to the unit. If the suction pressure falls below 20 psig, the switch will open and de-energize the outdoor unit. The switch will close again when the suction pressure increases above 35 psig. When the switch opens and then closes, there is a 3 minute short cycling delay before the outdoor unit will energize. Under normal conditions the switch is closed. Charging the Unit in AC mode If the outdoor temperature is 65 degrees F or higher: After completing the refrigerant line connections, leak checking the system, and evacuating the indoor section and all line connections (using proper methods), perform the following steps: 1. Determine the recommended charge addition (if applicable) for the system being installed. This information is in the unit’s QRD (Quick Reference Data sheet). 2. Calculate the amount of additional refrigerant needed for the line set length of the actual installation. This information is on the first page of the unit’s QRD (Quick Reference Data sheet). 3. Weigh in the additional charge amounts determined by step 1 and 2 above. 4. Adjust the charge to match the superheat (for fixed orifice systems) or subcooling (for TXV systems). There are three different resources for doing this: a.) The chargecalculator.com website. This will walk you through the charging process step by step. b.) The charging tables on the inside of the outdoor unit’s electrical box cover panel. These tables provide superheat targets for fixed orifice systems and subcooling targets for TXV systems. The system should be charged so that the measured superheat/ subcooling are within 1 degree F of the target listed in the table. For fixed orifice systems: • If your measured superheat at the suction valve is LESS THAN the recommended superheat value in the table then REMOVE refrigerant. • If your measured superheat at the suction valve is GREATER THAN the recommended superheat value in the table then ADD refrigerant. For TXV systems: • If your measured subcooling at the liquid valve is LESS THAN the recommended subcooling value in the table then ADD refrigerant. • If your measured subcooling at the liquid valve is GREATER THAN the recommended subcooling value in the table then REMOVE refrigerant. c.) The charging tables in the Supplemental Charging Information, can be found online in the literature library. The tables can also be accessed by scanning the QR code on the unit’s electrical panel. The pressures listed in these tables are for reference only and are to be used in troubleshooting a system. The system should be charged to match the superheat or subcooling targets as previously noted and not to match the system pressures. Follow the same procedure described in 4b above. If the outdoor temperature is between 35 degrees F and 65 degrees F: After completing the refrigerant line connections, leak checking the system, and evacuating the indoor section and all line connections (using proper methods), perform the following steps: 1. Determine the recommended charge addition (if applicable) for the system being installed. This information is in the unit’s QRD (Quick Reference Data sheet). 2. Calculate the amount of additional refrigerant needed for the line set length of the actual installation. This information 9 superheat/subcooling are within 1 degree F of the target listed in the table. For fixed orifice systems: • If your measured superheat at the suction valve is LESS THAN the recommended superheat value in the table then REMOVE refrigerant. • If your measured superheat at the suction valve is GREATER THAN the recommended superheat value in the table then ADD refrigerant. For TXV systems: NOTE: One half of the unit should be covered corner to corner. Figure 8. Blocked Off Outdoor Fan Discharge is on the first page of the unit’s QRD (Quick Reference Data sheet). 3. Weigh in the additional charge amounts determined by step 1 and 2 above. 4. Block off the discharge of the outdoor fan. NOTE: One half of the unit should be covered corner to corner as shown in Figure 8 (page 10). 5. With the unit in cooling mode, Adjust the charge to match the superheat (for fixed orifice systems) or subcooling (for TXV systems). There are two different resources for doing this: a.) The chargecalculator.com website. This will walk you through the charging process step by step. b.) The low ambient charging tables on the inside of the outdoor unit’s electrical box cover panel. These tables provide superheat targets for fixed orifice systems and subcooling targets for TXV systems. The system should be charged so that the measured 10 • If your measured subcooling at the liquid valve is LESS THAN the recommended subcooling value in the table then ADD refrigerant. • If your measured subcooling at the liquid valve is GREATER THAN the recommended subcooling value in the table then REMOVE refrigerant If the outdoor temperature is below 35 degrees F: After completing the refrigerant line connections, leak checking the system, and evacuating the indoor section and all line connections (using proper methods), perform the following steps: 1. Determine the recommended charge addition (if applicable) for the system being installed. This information is in the unit’s QRD (Quick Reference Data sheet). 2. Calculate the amount of additional refrigerant needed for the line set length of the actual installation. This information is on the first page of the unit’s QRD (Quick Reference Data sheet). 3. Weigh in the additional charge amounts determined by steps 1 and 2 above. 4. Return to the system when the outdoor temperature is 35 degrees F or higher and follow the steps defined in step 4 of the “If the outdoor temperature is between 35 degrees and 65 degrees F" or "If the outdoor temperature is 65 degree F or higher” sections above as applicable. YELLOW C R C OUTDOOR FAN MOTOR S COMPRESSOR HPS Y W2 THERMOSTAT R O C E ODT HP2 HP1 LP2 LP1 W2 OUT RV2 RV1 Y2 IN Y1 IN R O C W2 IN (24V COM) Y1 OUT Y2 OUT HOT1 HOT2 COIL#1 TEMP (OPTIONAL OUTDOOR THERMOSTAT) RVS LPS HGBP HPS COIL SENSOR 5 Y O C W2 C W2 IN THERMOSTAT R Y1 IN R O E ODT Y2 IN HP2 HP1 LP2 LP1 W2 OUT RV2 RV1 COIL#1 TEMP HOT1 HOT2 (24V COM) Y1 OUT Y2 OUT OUTDOOR FAN1 FAN2 CCH2 CCH1 TEMP DEFROST CONTROL BOARD AMB SENSOR BLACK AMB SENSOR - Ambient Sensor CC - Contactor Coil CCH - Crankcase Heater HPS - High Pressure Switch HGBP - Hot Gas By Pass Valve LPS - Low Pressure Switch RVS - Reversing Valve Solenoid * HARD START KIT (OPTIONAL) HGBP COIL SENSOR OUTDOOR TEMP FAN1 FAN2 CCH2 CCH1 CCH T2 L2 CAPACITOR F BLACK BLACK BLACK BLACK BLACK H C L1 T1 L2 R S GRD GROUNDING SCREW C COMPRESSOR R BLACK 04/16 711316C BLACK/ BLACK WHITE YELLOW/ YELLOW BLACK S C OUTDOOR FAN MOTOR Single Phase RED/RED BLACK BLUE (SINGLE PHASE) FIELD SUPPLY L1 L2 T2 ORANGE CONTACTOR CC BLACK CCH (OPTIONAL OUTDOOR THERMOSTAT) RVS LPS 2 YELLOW CC R DEFROST CONTROL BOARD AMB SENSOR C F DUAL CAPACITOR H S T1 L1 NOTES: 1. Disconnect all power before servicing. 1. Couper le courant avant de faire letretien. 2. For supply connections use copper conductors only. 2. Employez uniquement des conducteurs en cuivre. 3. Not suitable on systems that exceed 150 volts to ground 3. Ne convient pas aux installations de plus de 150 volt a la terre. 4. For replacement wires use conductors suitable for 105˚ C. 5. For ampacities and overcurrent protection, see unit rating plate. START RELAY* 6. Connect to 24 vac/40va/class 2 circuit. See furnace/air handler START LEGEND: installation instructions for control circuit and optional CAPACITOR* 1 FIELD WIRING relay/transformer kits. LOW VOLTAGE DUAL 208/230V HIGH VOLTAGE Split System Heat Pump (Outdoor Section) WIRING DIAGRAM WIRING DIAGRAMS CC Figure 9. Wiring Diagram for *SH(1,2)BE4M1SP (1.5 Ton - 4 Ton) (with Low Pressure Switch) 11 L1 Y2 Y1 C G ECM L2 TO UNIT GROUND LUG OUTDOOR FAN MOTOR C COMPRESSOR HGBP HPS COIL SENSOR AMB SENSOR CCH T2 L2 Figure 10. Wiring Diagram for *SH(1,2)BE4M1SP60K (5 Ton) (with Low Pressure Switch) Y W2 E ODT RVS LPS (OPTIONAL OUTDOOR THERMOSTAT THERMOSTAT) R O C HP2 HP1 LP2 LP1 W2 OUT RV2 RV1 Y2 IN Y1 IN R O C W2 IN HOT1 HOT2 (24V COM) Y1 OUT Y2 OUT COIL#1 TEMP OUTDOOR TEMP FAN1 FAN2 CCH2 CCH1 DEFROST CONTROL BOARD S R 208/230V HPS HGBP L2 G GREEN 5 LPS Y W2 BROWN YELLOW THERMOSTAT R O C Y1 IN R O C W2 IN E ODT Y2 IN HP2 HP1 LP2 LP1 W2 OUT RV2 RV1 COIL#1 TEMP HOT1 HOT2 (24V COM) Y1 OUT Y2 OUT OUTDOOR TEMP FAN1 FAN2 CCH2CCH1 TO UNIT GROUND LUG OUTDOOR FAN MOTOR DEFROST CONTROL BOARD BLUE L1 ECM Y1 Y2 C 1 BLACK BLACK BLACK BLACK BLACK CC CONTACTOR BLACK CCH START CAPACITOR* BLACK (OPTIONAL OUTDOOR THERMOSTAT) RVS 2 START RELAY* 1. Couper le courant avant de faire letretien. 2. Employez uniquement des conducteurs en cuivre. 3. Ne convient pas aux installations de plus de 150 volt a la terre. BLACK AMB SENSOR - Ambient Sensor CC - Contactor Coil CCH - Crankcase Heater HPS - High Pressure Switch HGBP - Hot Gas By Pass Valve RVS - Reversing Valve Solenoid * HARD START KIT (OPTIONAL) LPS - Low Pressure Switch CC C H CAPACITOR T1 L1 NOTES: 1. Disconnect all power before servicing. 2. For supply connections use copper conductors only. 3. Not suitable on systems that exceed 150 volts to ground 4. For replacement wires use conductors suitable for 105˚ C. 5. For ampacities and overcurrent protection, see unit rating plate. 6. Connect to 24 vac/40va/class 2 circuit. See furnace/air handler installation instructions for control circuit and optional relay/transformer kits. AMB SENSOR WHITE Split System Heat Pump (Outdoor Section) - High Speed ECM Motor WIRING DIAGRAM COIL SENSOR 12 L2 L2 T2 GRD (SINGLE PHASE) FIELD SUPPLY L1 L1 T1 C H C COMPRESSOR 07/19 1025295A (Replaces 10252950) GROUNDING SCREW BLACK/ BLACK WHITE S R CAPACITOR YELLOW/ YELLOW BLACK YELLOW FIELD WIRING LOW VOLTAGE HIGH VOLTAGE LEGEND: Single Phase RED/RED BLACK YELLOW CC YELLOW R R C OUTDOOR FAN MOTOR S COMPRESSOR C HPS LPS Y W2 THERMOSTAT R O C E ODT HP2 HP1 LP2 LP1 W2 OUT RV2 RV1 Y2 IN Y1 IN R O C W2 IN HOT1 HOT2 (24V COM) Y1 OUT Y2 OUT COIL#1 TEMP (OPTIONAL OUTDOOR THERMOSTAT) RVS HGBP HPS COIL SENSOR 5 LPS BLACK Y W2 E THERMOSTAT R O C Y1 IN R O C W2 IN RVS R C Y P CORESENSE BLACK BLACK BLACK 2 CAPACITOR F BLACK CCH H C L1 T1 L2 R S GRD 01/19 10252930 (Replaces 711341C) GROUNDING SCREW C COMPRESSOR R BLACK BLACK/ BLACK WHITE YELLOW/ YELLOW BLACK S C OUTDOOR FAN MOTOR Single Phase RED/RED BLACK BLUE (SINGLE PHASE) FIELD SUPPLY L1 L2 T2 ORANGE CONTACTOR CC BLACK BLACK (OPTIONAL OUTDOOR THERMOSTAT) RED YELLOW ODT Y2 IN HP2 HP1 LP2 LP1 W2 OUT RV2 RV1 COIL#1 TEMP HOT1 HOT2 (24V COM) Y1 OUT Y2 OUT OUTDOOR TEMP FAN1 FAN2 CCH2CCH1 DEFROST CONTROL BOARD AMB SENSOR BLACK AMB SENSOR - Ambient Sensor CC - Contactor Coil CCH - Crankcase Heater HPS - High Pressure Switch HGBP - Hot Gas By Pass Valve RVS - Reversing Valve Solenoid * HARD START KIT (OPTIONAL) LPS - Low Pressure Switch CC R C Y P COIL SENSOR CORESENSE HGBP CCH T2 L2 OUTDOOR TEMP FAN1 FAN2 CCH2 CCH1 DEFROST CONTROL BOARD AMB SENSOR C F DUAL CAPACITOR H S T1 L1 NOTES: 1. Disconnect all power before servicing. 1. Couper le courant avant de faire letretien. 2. For supply connections use copper conductors only. 2. Employez uniquement des conducteurs en cuivre. 3. Not suitable on systems that exceed 150 volts to ground 3. Ne convient pas aux installations de plus de 150 volt a la terre. 4. For replacement wires use conductors suitable for 105˚ C. 5. For ampacities and overcurrent protection, see unit rating plate. START RELAY* 6. Connect to 24 vac/40va/class 2 circuit. See furnace/air handler START LEGEND: installation instructions for control circuit and optional CAPACITOR* 1 FIELD WIRING relay/transformer kits. LOW VOLTAGE DUAL 208/230V HIGH VOLTAGE Split System Heat Pump (Outdoor Section) WIRING DIAGRAM YELLOW CC Figure 11. Wiring Diagram for *SH1BE4M1SP (1.5 - 4 Ton) (with CoreSenseTM and Low Pressure Switch) 13 L1 Y2 Y1 C G ECM L2 HPS R C Y P CORESENSE HGBP COIL SENSOR AMB SENSOR CCH TO UNIT GROUND LUG OUTDOOR FAN MOTOR C COMPRESSOR T2 Y Figure 12. Wiring Diagram for *SH1BE4M1SP60KA (5 Ton) (with CoreSenseTM and Low Pressure Switch) W2 E ODT RVS (OPTIONAL OUTDOOR THERMOSTAT THERMOSTAT) R O C HP2 HP1 LP2 LP1 W2 OUT RV2 RV1 Y2 IN Y1 IN R O C W2 IN HOT1 HOT2 (24V COM) Y1 OUT Y2 OUT COIL#1 TEMP OUTDOOR TEMP FAN1 FAN2 CCH2 CCH1 DEFROST CONTROL BOARD S R L2 COIL SENSOR HPS HGBP BLUE L1 ECM G TO UNIT GROUND LUG GREEN 5 LPS Y W2 BROWN YELLOW THERMOSTAT R O C Y1 IN R O C W2 IN E ODT Y2 IN BLACK BLACK BLACK BLACK BLACK (OPTIONAL OUTDOOR THERMOSTAT) R C Y P CORESENSE RVS 2 RED BLACK HP2 HP1 LP2 LP1 W2 OUT RV2 RV1 COIL#1 TEMP HOT1 HOT2 (24V COM) Y1 OUT Y2 OUT OUTDOOR TEMP FAN1 FAN2 CCH2CCH1 DEFROST CONTROL BOARD L2 Y1 Y2 C OUTDOOR FAN MOTOR 1 START RELAY* CC CONTACTOR BLACK CCH START CAPACITOR* BLACK 1. Couper le courant avant de faire letretien. 2. Employez uniquement des conducteurs en cuivre. 3. Ne convient pas aux installations de plus de 150 volt a la terre. BLACK AMB SENSOR - Ambient Sensor CC - Contactor Coil CCH - Crankcase Heater HPS - High Pressure Switch HGBP - Hot Gas By Pass Valve RVS - Reversing Valve Solenoid * HARD START KIT (OPTIONAL) LPS - Low Pressure Switch CC C H CAPACITOR T1 L1 208/230V NOTES: 1. Disconnect all power before servicing. 2. For supply connections use copper conductors only. 3. Not suitable on systems that exceed 150 volts to ground 4. For replacement wires use conductors suitable for 105˚ C. 5. For ampacities and overcurrent protection, see unit rating plate. 6. Connect to 24 vac/40va/class 2 circuit. See furnace/air handler installation instructions for control circuit and optional relay/transformer kits. AMB SENSOR WHITE Split System Heat Pump (Outdoor Section) - High Speed ECM Motor WIRING DIAGRAM BLACK 14 L2 L2 T2 GRD (SINGLE PHASE) FIELD SUPPLY L1 L1 T1 C H C COMPRESSOR 08/19 10285680 (Replaces 1027048A) GROUNDING SCREW BLACK/ BLACK WHITE S R CAPACITOR YELLOW/ YELLOW BLACK YELLOW FIELD WIRING LOW VOLTAGE HIGH VOLTAGE LEGEND: Single Phase RED/RED BLACK YELLOW CC YELLOW C R C OUTDOOR FAN MOTOR S COMPRESSOR HPS LPS Y W2 THERMOSTAT R O C E ODT HP2 HP1 LP2 LP1 W2 OUT RV2 RV1 Y2 IN Y1 IN R O C W2 IN HOT1 HOT2 (24V COM) Y1 OUT Y2 OUT COIL#1 TEMP OUTDOOR TEMP FAN1 FAN2 CCH2 CCH1 CCH T2 L2 RVS HGBP HPS COIL SENSOR 5 Y W2 BROWN THERMOSTAT R O C Y1 IN R O C W2 IN E ODT Y2 IN HP2 HP1 LP2 LP1 W2 OUT RV2 RV1 COIL#1 TEMP HOT1 HOT2 (24V COM) Y1 OUT Y2 OUT LPS OUTDOOR TEMP FAN1 FAN2 CCH2CCH1 DEFROST CONTROL BOARD AMB SENSOR BLACK AMB SENSOR - Ambient Sensor CC - Contactor Coil CCH - Crankcase Heater HPS - High Pressure Switch HGBP - Hot Gas By Pass Valve RVS - Reversing Valve Solenoid ODT - Outdoor Thermostat * HARD START KIT (OPTIONAL) LPS -Low Pressure Switch HGBP COIL SENSOR CC R DEFROST CONTROL BOARD AMB SENSOR C F DUAL CAPACITOR H S T1 L1 CAPACITOR F BLACK BLACK BLACK BLACK BLACK BROWN RVS 2 L1 T1 L2 R S GRD GROUNDING SCREW C COMPRESSOR R BLACK 01/19 10252920 (New) BLACK/ BLACK WHITE YELLOW/ YELLOW BLACK S C OUTDOOR FAN MOTOR Single Phase RED/RED BLACK BLUE (SINGLE PHASE) FIELD SUPPLY L1 L2 T2 ORANGE CONTACTOR CC BLACK CCH H C NOTES: 1. Disconnect all power before servicing. 1. Couper le courant avant de faire letretien. 2. For supply connections use copper conductors only. 2. Employez uniquement des conducteurs en cuivre. 3. Not suitable on systems that exceed 150 volts to ground 3. Ne convient pas aux installations de plus de 150 volt a la terre. 4. For replacement wires use conductors suitable for 105˚ C. 5. For ampacities and overcurrent protection, see unit rating plate. START RELAY* 6. Connect to 24 vac/40va/class 2 circuit. See furnace/air handler START LEGEND: installation instructions for control circuit and optional CAPACITOR* 1 FIELD WIRING relay/transformer kits. LOW VOLTAGE DUAL 208/230V HIGH VOLTAGE Split System Heat Pump (Outdoor Section) WIRING DIAGRAM YELLOW CC Figure 13. Wiring Diagram for *SH1BE4M1SP with Low Pressure Switch (Manufactured Housing) 15 16 YELLOW R C OUTDOOR FAN MOTOR S COMPRESSOR C HPS Y W2 THERMOSTAT R O C E ODT HP2 HP1 LP2 LP1 W2 OUT RV2 RV1 Y2 IN Y1 IN R O C W2 IN HOT1 HOT2 (24V COM) Y1 OUT Y2 OUT COIL#1 TEMP OUTDOOR TEMP FAN1 FAN2 CCH2 CCH1 CCH T2 L2 RVS HGBP HPS COIL SENSOR 5 Y Figure 14. Wiring Diagram for *SH2BE4M1RP (Manufactured Housing) W2 THERMOSTAT R O C Y1 IN R O C W2 IN E ODT Y2 IN HP2 HP1 LP2 LP1 W2 OUT RV2 RV1 COIL#1 TEMP HOT1 HOT2 (24V COM) Y1 OUT Y2 OUT OUTDOOR TEMP FAN1 FAN2 CCH2CCH1 DEFROST CONTROL BOARD AMB SENSOR BLACK AMB SENSOR - Ambient Sensor CC - Contactor Coil CCH - Crankcase Heater HPS - High Pressure Switch HGBP - Hot Gas By Pass Valve RVS - Reversing Valve Solenoid * HARD START KIT (OPTIONAL) HGBP COIL SENSOR AMB SENSOR CC S R DEFROST CONTROL BOARD C F H DUAL CAPACITOR PTCR T1 L1 CAPACITOR F BLACK BLACK BLACK BLACK BLACK BLACK BLACK BROWN PTCR RVS 2 L1 T1 L2 R S GRD GROUNDING SCREW C COMPRESSOR R BLACK 10/18 10252180 BLACK/ BLACK WHITE YELLOW/ YELLOW BLACK S C OUTDOOR FAN MOTOR Single Phase RED/RED BLACK BLUE (SINGLE PHASE) FIELD SUPPLY L1 L2 T2 ORANGE CONTACTOR CC BLACK CCH H C NOTES: 1. Disconnect all power before servicing. 1. Couper le courant avant de faire letretien. 2. For supply connections use copper conductors only. 2. Employez uniquement des conducteurs en cuivre. 3. Not suitable on systems that exceed 150 volts to ground 3. Ne convient pas aux installations de plus de 150 volt a la terre. 4. For replacement wires use conductors suitable for 105˚ C. 5. For ampacities and overcurrent protection, see unit rating plate. START RELAY* 6. Connect to 24 vac/40va/class 2 circuit. See furnace/air handler START LEGEND: installation instructions for control circuit and optional CAPACITOR* 1 FIELD WIRING relay/transformer kits. LOW VOLTAGE DUAL 208/230V HIGH VOLTAGE Split System Heat Pump (Outdoor Section) WIRING DIAGRAM YELLOW CC YELLOW R C OUTDOOR FAN MOTOR S COMPRESSOR C HPS Y W2 THERMOSTAT R O C E ODT HP2 HP1 LP2 LP1 W2 OUT RV2 RV1 Y2 IN Y1 IN R O C W2 IN HOT1 HOT2 (24V COM) Y1 OUT Y2 OUT COIL#1 TEMP OUTDOOR TEMP FAN1 FAN2 CCH2 CCH1 CCH T2 L2 RVS HGBP HPS COIL SENSOR 5 Y W2 BROWN THERMOSTAT R O C Y1 IN R O C W2 IN E ODT Y2 IN HP2 HP1 LP2 LP1 W2 OUT RV2 RV1 COIL#1 TEMP HOT1 HOT2 (24V COM) Y1 OUT Y2 OUT OUTDOOR TEMP FAN1 FAN2 CCH2CCH1 DEFROST CONTROL BOARD AMB SENSOR BLACK AMB SENSOR - Ambient Sensor CC - Contactor Coil CCH - Crankcase Heater HPS - High Pressure Switch HGBP - Hot Gas By Pass Valve RVS - Reversing Valve Solenoid ODT - Outdoor Thermostat * HARD START KIT (OPTIONAL) HGBP COIL SENSOR CC R DEFROST CONTROL BOARD AMB SENSOR C F DUAL CAPACITOR H S T1 L1 CAPACITOR F BLACK BLACK BLACK BLACK BLACK BROWN RVS 2 L1 T1 L2 R S GRD GROUNDING SCREW C COMPRESSOR R BLACK 03/18 10214360 (New) BLACK/ BLACK WHITE YELLOW/ YELLOW BLACK S C OUTDOOR FAN MOTOR Single Phase RED/RED BLACK BLUE (SINGLE PHASE) FIELD SUPPLY L1 L2 T2 ORANGE CONTACTOR CC BLACK CCH H C NOTES: 1. Disconnect all power before servicing. 1. Couper le courant avant de faire letretien. 2. For supply connections use copper conductors only. 2. Employez uniquement des conducteurs en cuivre. 3. Not suitable on systems that exceed 150 volts to ground 3. Ne convient pas aux installations de plus de 150 volt a la terre. 4. For replacement wires use conductors suitable for 105˚ C. 5. For ampacities and overcurrent protection, see unit rating plate. START RELAY* 6. Connect to 24 vac/40va/class 2 circuit. See furnace/air handler START LEGEND: installation instructions for control circuit and optional CAPACITOR* 1 FIELD WIRING relay/transformer kits. LOW VOLTAGE DUAL 208/230V HIGH VOLTAGE Split System Heat Pump (Outdoor Section) WIRING DIAGRAM YELLOW CC Figure 15. Wiring Diagram for *SH2BE4M1SP (Manufactured Housing) 17 18 YELLOW R C OUTDOOR FAN MOTOR S COMPRESSOR C HPS Figure 16. Wiring Diagram for *SH2BE4M1RP (Builder's Series) Y W2 THERMOSTAT R O C E RVS HGBP HPS COIL SENSOR (OPTIONAL OUTDOOR THERMOSTAT) ODT HP2 HP1 LP2 LP1 W2 OUT RV2 RV1 Y2 IN Y1 IN R O C W2 IN HOT1 HOT2 (24V COM) Y1 OUT Y2 OUT COIL#1 TEMP OUTDOOR TEMP FAN1 FAN2 CCH2 CCH1 CCH T2 L2 5 Y W2 THERMOSTAT R O C Y1 IN R O C W2 IN E ODT Y2 IN HP2 HP1 LP2 LP1 W2 OUT RV2 RV1 COIL#1 TEMP HOT1 HOT2 (24V COM) Y1 OUT Y2 OUT OUTDOOR TEMP FAN1 FAN2 CCH2CCH1 DEFROST CONTROL BOARD AMB SENSOR BLACK AMB SENSOR - Ambient Sensor CC - Contactor Coil CCH - Crankcase Heater HPS - High Pressure Switch HGBP - Hot Gas By Pass Valve RVS - Reversing Valve Solenoid * HARD START KIT (OPTIONAL) HGBP COIL SENSOR AMB SENSOR CC S R DEFROST CONTROL BOARD C F H DUAL CAPACITOR PTCR T1 L1 CAPACITOR F PTCR BLACK BLACK BLACK BLACK BLACK BLACK BLACK (OPTIONAL OUTDOOR THERMOSTAT) RVS 2 L1 T1 L2 R S GRD CC 06/19 10272300 (Replaces 10066150) GROUNDING SCREW C COMPRESSOR R BLACK BLACK/ BLACK WHITE YELLOW/ YELLOW BLACK S C OUTDOOR FAN MOTOR Single Phase RED/RED BLACK BLUE (SINGLE PHASE) FIELD SUPPLY L1 L2 T2 ORANGE CONTACTOR CC BLACK CCH H C NOTES: 1. Couper le courant avant de faire letretien. 1. Disconnect all power before servicing. 2. Employez uniquement des conducteurs en cuivre. 2. For supply connections use copper conductors only. 3. Ne convient pas aux installations de plus de 150 volt a la terre. 3. Not suitable on systems that exceed 150 volts to ground 4. For replacement wires use conductors suitable for 105˚ C. 5. For ampacities and overcurrent protection, see unit rating plate. START RELAY* 6. Connect to 24 vac/40va/class 2 circuit. See furnace/air handler START LEGEND: installation instructions for control circuit and optional CAPACITOR* 1 FIELD WIRING relay/transformer kits. LOW VOLTAGE DUAL 208/230V HIGH VOLTAGE Split System Heat Pump (Outdoor Section) WIRING DIAGRAM YELLOW YELLOW R C OUTDOOR FAN MOTOR S COMPRESSOR C HPS CCH T2 L2 Y W2 THERMOSTAT R O C E ODT HP2 HP1 LP2 LP1 W2 OUT RV2 RV1 Y2 IN Y1 IN R O C W2 IN HOT1 HOT2 (24V COM) Y1 OUT Y2 OUT COIL#1 TEMP RVS HGBP HPS COIL SENSOR (OPTIONAL OUTDOOR THERMOSTAT) OUTDOOR TEMP FAN1 FAN2 CCH2 CCH1 AMB SENSOR - Ambient Sensor CC - Contactor Coil CCH - Crankcase Heater HPS - High Pressure Switch HGBP - Hot Gas By Pass Valve RVS - Reversing Valve Solenoid * HARD START KIT (OPTIONAL) HGBP COIL SENSOR CC R DEFROST CONTROL BOARD AMB SENSOR C F DUAL CAPACITOR H S T1 L1 CAPACITOR F Y O C W2 C W2 IN THERMOSTAT R Y1 IN R O E ODT Y2 IN HP2 HP1 LP2 LP1 W2 OUT RV2 RV1 COIL#1 TEMP HOT1 HOT2 (24V COM) Y1 OUT Y2 OUT OUTDOOR FAN1 FAN2 CCH2 CCH1 TEMP DEFROST CONTROL BOARD AMB SENSOR 5 BLACK BLACK BLACK BLACK BLACK H C L1 T1 L2 R S GRD GROUNDING SCREW C COMPRESSOR R BLACK 04/16 711315C BLACK/ BLACK WHITE YELLOW/ YELLOW BLACK S C OUTDOOR FAN MOTOR Single Phase RED/RED BLACK BLUE (SINGLE PHASE) FIELD SUPPLY L1 L2 T2 ORANGE CONTACTOR CC BLACK CCH (OPTIONAL OUTDOOR THERMOSTAT) RVS 2 NOTES: 1. Disconnect all power before servicing. 1. Couper le courant avant de faire letretien. 2. For supply connections use copper conductors only. 2. Employez uniquement des conducteurs en cuivre. 3. Not suitable on systems that exceed 150 volts to ground 3. Ne convient pas aux installations de plus de 150 volt a la terre. 4. For replacement wires use conductors suitable for 105˚ C. 5. For ampacities and overcurrent protection, see unit rating plate. START RELAY* 6. Connect to 24 vac/40va/class 2 circuit. See furnace/air handler START LEGEND: installation instructions for control circuit and optional CAPACITOR* 1 FIELD WIRING relay/transformer kits. LOW VOLTAGE DUAL 208/230V HIGH VOLTAGE Split System Heat Pump (Outdoor Section) WIRING DIAGRAM YELLOW CC BLACK Figure 17. Wiring Diagram for *SH2BE4M1SP (1 - 4 Ton) (Builder's Series) 19 Y2 Y1 L1 C G ECM L2 TO UNIT GROUND LUG OUTDOOR FAN MOTOR C COMPRESSOR HGBP HPS COIL SENSOR AMB SENSOR CCH T2 L2 Figure 18. Wiring Diagram for *SH2BE4M1SP (5 Ton) (Builder's Series) Y W2 E ODT RVS (OPTIONAL OUTDOOR THERMOSTAT THERMOSTAT) R O C HP2 HP1 LP2 LP1 W2 OUT RV2 RV1 Y2 IN Y1 IN R O C W2 IN HOT1 HOT2 (24V COM) Y1 OUT Y2 OUT COIL#1 TEMP OUTDOOR TEMP FAN1 FAN2 CCH2 CCH1 DEFROST CONTROL BOARD S R 208/230V AMB SENSOR HPS HGBP BLUE L1 ECM G TO UNIT GROUND LUG GREEN 5 1 Y W2 BROWN YELLOW THERMOSTAT R O C Y1 IN R O C W2 IN E ODT Y2 IN HP2 HP1 LP2 LP1 W2 OUT RV2 RV1 COIL#1 TEMP HOT1 HOT2 (24V COM) Y1 OUT Y2 OUT OUTDOOR TEMP FAN1 FAN2 CCH2CCH1 DEFROST CONTROL BOARD L2 Y2 C Y1 OUTDOOR FAN MOTOR BLACK BLACK BLACK BLACK BLACK CC CONTACTOR BLACK CCH START CAPACITOR* (OPTIONAL OUTDOOR THERMOSTAT) RVS 2 START RELAY* 1. Couper le courant avant de faire letretien. 2. Employez uniquement des conducteurs en cuivre. 3. Ne convient pas aux installations de plus de 150 volt a la terre. BLACK AMB SENSOR - Ambient Sensor CC - Contactor Coil CCH - Crankcase Heater HPS - High Pressure Switch HGBP - Hot Gas By Pass Valve RVS - Reversing Valve Solenoid * HARD START KIT (OPTIONAL) CC C H CAPACITOR T1 L1 NOTES: 1. Disconnect all power before servicing. 2. For supply connections use copper conductors only. 3. Not suitable on systems that exceed 150 volts to ground 4. For replacement wires use conductors suitable for 105˚ C. 5. For ampacities and overcurrent protection, see unit rating plate. 6. Connect to 24 vac/40va/class 2 circuit. See furnace/air handler installation instructions for control circuit and optional relay/transformer kits. COIL SENSOR WHITE Split System Heat Pump (Outdoor Section) - High Speed ECM Motor WIRING DIAGRAM BLACK 20 L2 L2 T2 GRD (SINGLE PHASE) FIELD SUPPLY L1 L1 T1 C H C COMPRESSOR 07/19 1014852A (Replaces 10148520) GROUNDING SCREW BLACK/ BLACK WHITE S R CAPACITOR YELLOW/ YELLOW BLACK YELLOW FIELD WIRING LOW VOLTAGE HIGH VOLTAGE LEGEND: Single Phase RED/RED BLACK YELLOW CC 21 22 23 INSTALLATION CHECKLIST ELECTRICAL SYSTEM INSTALLATION ADDRESS: CITY: STATE: Electrical connections tight? YES NO Line voltage polarity correct? YES NO UNIT MODEL #: Rated Voltage: UNIT SERIAL #: Has the thermostat been calibrated? YES NO Is the thermostat level? YES NO Is the heat anticipator setting correct? (If Applicable) YES NO Unit Installed Minimum clearances per Figure 1 (page 3)? YES NO INSTALLER NAME: CITY: REPLACEMENT PARTS STATE: Has the owner’s information been reviewed with the customer? YES NO Has the Literature Package been left with the unit? YES NO Replacement parts are available through your distributor. Please have the complete model and serial number of the unit when ordering replacement parts. Capacitors REFRIGERATION SYSTEM Was unit given 24 hr warm up period for crankcase heaters? YES NO Compressors Thermostats Contactors Time Delay Relays Pressure Switches Transformers Relays Stage-1 Liquid Pressure (High Side): Stage-1 Suction Pressure (Low Side): ELECTRICAL: Temperature Limit Switches Blower Motor Fan Motor Blower Assembly Cabinet Panels MOTORS: COMPONENTS: Fan Grille Filter/Driers Expansion Valves Specifications & illustrations subject to change without notice or incurring obligations (10/20). O’Fallon, MO, © Nortek Global HVAC LLC 2020. All Rights Reserved. 10348110 (Replaces 10285690)
advertisement
Related manuals
advertisement
Table of contents
- 2 IMPORTANT SAFETY INFORMATION
- 3 HEAT PUMP INSTALLATION
- 3 General Information
- 3 Before You Install the Heat Pump
- 3 Locating the Heat Pump
- 3 Packaging Removal
- 3 Ground Level
- 3 Rooftop
- 4 Outdoor Unit
- 4 Outdoor Orifice Removal & Installation
- 5 ELECTRICAL WIRING
- 5 Pre-Electrical Checklist
- 5 Line Voltage
- 5 Grounding
- 5 Thermostat / Low Voltage Connections
- 6 Diagnostics Module
- 6 Compressor Protection
- 6 Resetting Alert Codes
- 7 START UP & ADJUSTMENTS
- 7 Pre-Start Check List
- 7 Start-Up Procedures
- 7 Operating Temperatures
- 7 Air Circulation - Indoor Blower
- 7 Short Cycle Protection
- 7 System Cooling
- 7 System Heating
- 7 Defrost Control Board Test Pins
- 8 HEAT PUMP MAINTENANCE
- 8 Panel Removal
- 8 Panel Installation
- 9 REFRIGERANT CHARGING
- 9 Charging the Unit in AC mode
- 9 If the outdoor temperature is 65 degrees F or higher
- 9 65 degrees F
- 10 If the outdoor temperature is below 35 degrees F
- 11 WIRING DIAGRAMS
- 11 (1.5 Ton - 4 Ton)
- 12 (5 Ton)
- 15 Pressure Switch (Manufactured Housing)
- 16 (Manufactured Housing)
- 18 (Builder's Series)
- 19 Figure 17. Wiring Diagram for *SH2BE4M1SP (1 - 4 Ton)
- 20 Figure 18. Wiring Diagram for *SH2BE4M1SP (5 Ton)
- 24 INSTALLATION CHECKLIST
- 24 REPLACEMENT PARTS