CHIEF SMART-LIFT SL151 Installation Instructions Manual

Add to My manuals
16 Pages

advertisement

CHIEF SMART-LIFT SL151 Installation Instructions Manual | Manualzz

I N S T A L L A T I O N I N S T R U C T I O N S

Instrucciones de instalación

Installationsanleitung

Instruções de Instalação

Istruzioni di installazione

Installatie-instructies

Instructions d´installation

SMART-LIFT™ Electric Ceiling Lift

This device complies with part 15 of the FCC rules. Operation is subject to the following 2 conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

This equipment has been tested and found to comply with the limits of a Class B digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy, and if not installed and used in accordance with the instructions, may cause harmful interference to radio or television communications. However, there is no guarantee that the interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:

Reorient or relocate the receiving antenna

Increase the separation between the equipment and receiver

• Connect the equipment to an outlet on a circuit other than that to which the receiver is connected

Consult the dealer or an experienced radio/TV technician for help

SL151

SL151

DISCLAIMER

Milestone AV Technologies, and its affiliated corporations and subsidiaries (collectively, "Milestone"), intend to make this manual accurate and complete. However, Milestone makes no claim that the information contained herein covers all details, conditions or variations, nor does it provide for every possible contingency in connection with the installation or use of this product. The information contained in this document is subject to change without notice or obligation of any kind. Milestone makes no representation of warranty, expressed or implied, regarding the information contained herein. Milestone assumes no responsibility for accuracy, completeness or sufficiency of the information contained in this document.

Chief® is a registered trademark of Milestone AV Technologies.

All rights reserved.

IMPORTANT SAFETY INSTRUCTIONS

WARNING

CAUTION

alerts you to the possibility of serious injury or death if you do not follow the instructions.

alerts you to the possibility of damage or destruction of equipment if you do not follow the corresponding instructions.

WARNING

:

FAILURE TO READ AND

FOLLOW THE FOLLOWING INSTRUCTIONS CAN RESULT

IN SERIOUS PERSONAL INJURY, DAMAGE TO EQUIPMENT

OR VOIDING OF FACTORY WARRANTY. It is the installer’s responsibility to make sure all components are properly assembled and installed using the instructions provided.

IMPORTANT ! :

Model SL151 is suitable for use in Other

Environmental Air Space in Accordance with Section 300.22(C) of the National Electrical Code.

When using an electrical mounting system, basic precautions should always be followed, including the following:

READ ALL INSTRUCTIONS BEFORE USING THIS

PRODUCT!!!!

DANGER:

TO REDUCE THE RISK OF

ELECTRIC SHOCK:

1.

Always turn off power at source before cleaning.

Installation Instructions

WARNING:

TO REDUCE THE RISK OF

BURNS, FIRE, ELECTRIC SHOCK, OR INJURY TO

PERSONS:

• Always turn off power at source before putting on or taking off parts.

• Use this mounting system only for its intended use as described in these instructions. Do NOT use attachments not recommended by the manufacturer.

• Never operate this mounting system if it has a damaged test cord or test plug. If it is not working properly during testing, return the mounting system to a service center for examination and repair.

• Keep the test power cord away from heated surfaces.

• Never operate the mounting system with the air openings blocked. Keep the air openings free of lint, hair, and the like.

• Never drop or insert any object into any opening.

• Do not use outdoors unless marked for outdoor use.

• Route cords and cables as shown in the installation instructions.

• To disconnect, turn all controls to the off position, then turn off power at source.

WARNING

:

RISK OF ELECTRIC SHOCK!

Connect this mounting system to a properly grounded outlet only. See Grounding Instructions.

CAUTION:

Changes or modifications to this unit not expressly approved by the manufacturer can void the units FCC compliance rating and make the unit illegal to operate.

WARNING

:

Failure to provide adequate structural strength for this component can result in serious personal injury or damage to equipment! It is the installer’s responsibility to make sure the structure to which this component is attached can support five times the combined weight of all equipment. Reinforce the structure as required before installing the component.

WARNING

:

Exceeding the weight capacity can result in serious personal injury or damage to equipment! It is the installer’s responsibility to make sure the weight of all components attached to the SL151 does not exceed 35 lbs

(15.9 kg).

WARNING

:

RISK OF INJURY! Do not place video equipment such as televisions or computer monitors on the ceiling panel of the SL151.

NOTE:

This system has no user serviceable parts.

--SAVE THESE INSTRUCTIONS--

2

Installation Instructions

TOOLS REQUIRED FOR INSTALLATION

SL151

PARTS

A (1)

[Ceiling Lift]

I/M x1

D (1)

[Push Button Assembly]

B (5)

[Cable Tie]

C (1)

[External Terminal

Cover Plate]

LEGEND

E (5)

[Cable Tie Mount]

Tighten Fastener

Apretar elemento de fijación

Befestigungsteil festziehen

Apertar fixador

Serrare il fissaggio

Bevestiging vastdraaien

Serrez les fixations

Loosen Fastener

Aflojar elemento de fijación

Befestigungsteil lösen

Desapertar fixador

Allentare il fissaggio

Bevestiging losdraaien

Desserrez les fixations

F (4)

6-32 x 3/16

G (2)

[Rubber Grommet]

H (1)

[Jumper Wire]

Phillips Screwdriver

Marcar con lápiz

Stiftmarkierung

Marcar com lápis

Segno a matita

Potloodmerkteken

Marquage au crayon

Adjust

Ajustar

Einstellen

Ajustar

Regolare

Afstellen

Ajuster

3

SL151

DIMENSIONS

[207.0]

8.15

Installation Instructions

DIMENSIONS: [MILLIMETERS]

INCHES

MAX PROJECTOR/EQUIPMENT SIZE:

Height: 8.375" [212.7mm]

Width: 18.25" [463.6mm]

Length: 18.25" [463.6mm]

Weight: 35# [15.9kg]

[596.9]

23.50

[410.2]

16.15

[578.6]

22.78

[413.8]

16.29

[596.9]

23.50

[582.7]

22.94

[571.5]

22.50

SLOTS ACCOMMODATE 3/8" THREADED ROD

TERMINAL BLOCK & COVER MAY

BE REMOVED IF MAKING ALL

CONNECTIONS DIRECTLY TO

THE CONTROL BOARD

[29.2] 1.15

[579.4]

22.81

[571.5]

22.50

MOUNTING TABS ACCEPT 1/4"

LAG BOLTS FOR JOIST MOUNTING

[65.5]

2.58

[284.5]

11.20

[68.1] 2.68 MIN

[101.6] 4.00 MAX

[514.1]

20.24

SLB MOUNTING SURFACE

[215.9]

8.50

[111.3] 4.38

[515.1]

20.28

TABLE OF CONTENTS

Disclaimer.....................................................2

Tools Required For Installation.................... 3

Parts..............................................................3

Legend..........................................................3

Dimensions...................................................4

Installation Requirements..............................5

Power Requirements.....................................5

Pre-test Lift Before Installation.......................5

Power Requirements And Wiring...................5

Grounding Instructions.................................. 6

Removing Ceiling Panel................................ 6

Installing in Ceiling.........................................6

-Installing In A Suspended Ceiling...............6

-Installing In A Wood Framework (Joists)....7

Installing Projector On SL151........................7

Adjustments...................................................7

Connecting Control Wiring.............................8

Connecting To Power Supply.........................8

Wiring Options............................................... 9

Re-Attaching Ceiling Panel............................9

Table 1: Wiring Table...................................10

Table 2: Internal Terminal Descriptions........11

Internal/External Wiring Terminal

Descriptions.....................................12

4

Installation Instructions

INSTALLATION REQUIREMENTS

The SL151 has been designed to be mounted either recessed into a ceiling, or flush-mounted in a finished ceiling.

Power Requirements

The SL151 requires 120VAC, 60 Hz and 12 amps power to operate.

Place jumper wire (H) (2 and 5)

SL151

IMPORTANT ! :

Installation and maintenance of this product must be completed by a qualified service technician.

Pre-Test Lift before Installation

1.

Carefully inspect the SL151 for any shipping damage. If any damage is apparent, do NOT continue with the installation.

Instead, contact Chief for further instructions.

2.

Place SL151 upside down on clean surface. (See Figure 1)

Wire push button assembly (D) ( 1 -red, 6 -black)

Figure 3

6.

Plug in the SL151 test cord. (See Figure 2)

NOTE:

(See Figure 2) for location of external wiring terminal.

(See Figure 4) for location of internal wiring terminal.

Internal wiring terminal

SL151 Top

Figure 1

3.

Remove and save two screws holding side electrical cover in place. (See Figure 2)

4.

Remove electrical cover. (See Figure 2)

Remove and save two screws

Test cord

4

Electrical

Cover

Remove cover

External wiring terminal

3 x 2

Figure 2

5.

Place the jumper wire (H) on the external wiring terminal contacts labeled 2 and 5 , and wire the push button assembly (D) to contacts 1 (red) and 6 (black) . (See

Figure 3).

[Some parts not shown for clarity]

Figure 4

Power Requirements and Wiring

The SL151 requires 120VAC, 60 Hz and 12 amps power to operate.

IMPORTANT ! :

This product must be grounded. If it should malfunction or break down, grounding provides a path of least resistance for electric current to reduce the risk of electric shock.

Grounding Instructions

This product is equipped with a test cord having an equipmentgrounding conductor and a grounding plug. The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.

5

SL151 Installation Instructions

WARNING:

RISK OF ELECTROCUTION! All electrical wiring required for installation should be installed by a qualified electrician.

Ceiling Panel Removed

WARNING:

PINCH HAZARD! FINGERS OR HANDS

BETWEEN MOVING PARTS CAN LEAD TO SEVERE

PERSONAL INJURY! Keep fingers and hands away from mount when operating.

7.

Press the push button to test the SL151 while it is still in the pre-test position.

• Press when the lift is at its extended position and it will retract.

• Press when the lift is at its retracted position and it will extend.

• Press while the lift is moving and it will stop.

• Leave SL151 in the open position.

Removing Ceiling Panel

1.

Remove and save screws attaching guide wires to ceiling panel. (See Figure 5)

Ceiling

Panel

Remove

Screw

(one on each side)

Figure 5

2.

Lift up on each corner of ceiling panel to remove pan from clips. (See Figure 6) and (See Figure 7)

Ceiling

Panel

Guide Wire

(one on each side)

Figure 7

INSTALLING IN CEILING

WARNING:

IMPROPER INSTALLATION CAN LEAD TO

LIFT FALLING CAUSING SEVERE PERSONAL INJURY OR

DAMAGE TO EQUIPMENT! It is the installers responsibility to make certain the structure to which the lift is being mounted is capable of supporting five times the weight of the lift and all attached equipment. Reinforce the structure as required before installing the lift.

NOTE:

The following instructions assume a suitable mounting structure and surface exists prior to installation and all power and signal wires and cables have been properly installed.

Installing in a Suspended Ceiling

NOTE:

The SL151 may be suspended from three 3/8 in.

diameter x 8 in. length (minimum) Grade 2 or better threaded rods (not provided) which are secured to a

1-5/8" x 1-5/8" 12ga metal framing channel (spanning a maximum of 5 feet--not provided) by Grade 2 or better

3/8" channel nuts (not provided).

1.

Turn SL151 over and place onto threaded rods, inserting the rods into the three slots on top of the SL151 housing.

(See Figure 8)

2.

Secure the threaded rods to the SL151 with Grade 2 or better 3/8 in. jam nuts (not provided) and washers (one of each on inside and one of each on outside-not provided).

Clip

Guide

Wire

(Top view of SL151)

Figure 6

Figure 8

Insert rods into

3 slots

6

Installation Instructions

Installing in a Wood Framework (Joists)

1.

Use 1/4" x 1-1/2" (minimum) Grade 2 lag screws (not provided) to secure SL151 to the joists or wood framework, using the mounting tabs located on the sides of the SL151 housing. (See Figure 9).

NOTE:

There are mounting tabs on each side and end of the

SL151. The SL151 only requires support on two opposing sides.

IMPORTANT ! :

Wood framework must be constructed of nothing larger than 2x6 wood studs across the rear of the

SL151.

The rear of the SL151 is the side with the test cord.

There are no size limitations for the wood framework on the other three sides of the SL151.

rear

Attachment

Points

SL151

Figure 10

Adjustments

1.

FORWARD/BACKWARD

• To shift projector mounting bracket backward or forward, remove and save two screws on each side.

• Move mounting bracket forward or backward as required.

• Reinstall and tighten screws. (See Figure 11)

Mounting

Tabs Mounting

Tabs

Figure 9

CAUTION:

The lift MUST be installed square and parallel.

Avoid stressing or bending the lift during installation.

2.

Use the provided push button (D) to operate the SL151 up and down, ensuring that all clearances are adequate.

Installing Projector on SL151

NOTE:

The projector is secured from the top by an SLB bracket (a Listed accessory).

1.

Attach the SLB bracket to the projector following the instructions included with the bracket.

2.

Attach the bracket with the projector to the SL151, adjusting left or right by using the various attachment points in the

SL151. (See Figure 10)

Figure 11

2.

YAW (Rotation)

• Adjust one or the other side of the bracket backward or forward by loosening two screws on each side. (See

Figure 12)

• Adjust bracket as required.

• Tighten screws. (See Figure 12)

7

SL151

Connecting Control Wiring

Installation Instructions

WARNING:

All wiring should be performed by a licensed electrician following all local codes and ordinances.

Figure 12

3.

PITCH

• Remove and save back screw on each side.

• Adjust vertically, as required.

• Reinstall and tighten screws. (See Figure 13)

4.

VERTICAL

• Remove and save front screw on each side.

• Adjust vertically, as required.

• Reinstall and tighten screws. (See Figure 13)

1.

Unplug the SL151’s test cord (used for testing).

2.

Remove the jumper wire and supplied push button wiring

(previously installed in the Pre-Test Lift before Installation section) from the external terminal block. (See Figure 3)

3.

Connect control wiring following instructions included with the controller and information in Table 1: Wiring Table

NOTE:

Any knockouts removed in the SL151 must be replaced with a supplied rubber grommet (G).

4.

Feed the video and/or communications cables through the knockout in the rear or top of the lift and connect it to the projector.

NOTE:

Ensure there is enough slack in the cables to allow for up and down movement of the lift.

5.

Secure cables as necessary using supplied mounting pads

(E) and cable ties (B).

CAUTION:

KEEP SL151 OPEN WHILE PROJECTOR IS

RUNNING OR IN COOLING MODE! Premature bulb failure or damage to electrical components may occur if lift closes.

NOTE:

If SL151 is cycled up and down repeatedly the motor’s thermal overload protection will stop operation.

Operation will resume when the thermal overload resets (usually within 3 to 5 minutes).

Connecting to Power Supply

IMPORTANT ! :

This product must be connected to a grounded metal, permanent wiring system, or an equipmentgrounding conductor must be run with the circuit conductors and connected to the equipment-grounding terminal or lead on the product.

4

3

Figure 13

5.

ROLL (Horizontal Tilt)

• Shift bracket up or down in the side holes on one side or the other by removing screws.

• Adjust and tighten screws on bracket. (See Figure 13)

WARNING:

FAILURE TO

DISCONNECT AND TERMINATE POWER

LEADS PROPERLY MAY RESULT IN

PERSONAL INJURY OR EQUIPMENT

DAMAGE!! Licensed electrician must disconnect and terminate the leads to the power cord receptacle, and must hard wire the SL151 to a 12-amp power source.

1.

Disconnect and remove power inlet from interior junction box.

2.

Hardwire unit to a 120V 60Hz 12-amp power source.

NOTE:

This unit was designed to have conduit run directly into the back of the interior junction box.

8

Installation Instructions

NOTE:

If installing the SL151 in a drywall ceiling, remove the outside terminal block and cover with plate (C), using four 6-32 x 3/16" Phillips pan head screws (F).

Wiring Options

NOTE:

Refer to Table 1: Wiring Table and (See Figure 16) for information on all wiring options.

NOTE:

Refer to Table 2: Terminal Descriptions and (See

Figure 16) for terminal descriptions, functions and wiring options.

Re-Attaching Ceiling Panel

1.

Line up rectangular holes in ceiling panel with clips on ends of rods, and re-attach the ceiling panel. (See Figure 14)

CAUTION:

Damage to equipment could result if clips are not lined up properly with rectangular holes.

Clips

Rectangular

Holes

Figure 14

2.

Carefully insert clips into rectangular holes in ceiling panel.

3.

Reattach guide wires (two places) to ceiling panel, using screws removed earlier. (See Figure 15)

Ceiling

Panel

Figure 15

x 2

Guide

Wire

SL151

9

SL151

Table 1: WIRING TABLE

Installation Instructions

EXTERNAL WIRING

INTERNAL

WIRING

Figure 16

NOTE:

The numbers listed in the SL151 Internal and SL151 External columns refer to the corresponding numbers located where indicated in the wiring pictures. (See Figure 16)

10

Installation Instructions

Table 2: INTERNAL TERMINAL DESCRIPTIONS

SL151

11

SL151 Installation Instructions

12

Figure 17

Installation Instructions SL151

13

SL151 Installation Instructions

14

Installation Instructions SL151

15

SL151 Installation Instructions

Chief Manufacturing, a products division of Milestone AV Technologies

8820-000041 Rev02

2010 Milestone AV Technologies, a

Duchossois Group Company www.chiefmfg.com

04/10

USA/International A 8401 Eagle Creek Parkway, Savage, MN 55378

P 800.582.6480 / 952.894.6280

Europe

F 877.894.6918 / 952.894.6918

A Fellenoord 130 5611 ZB EINDHOVEN, The Netherlands

P +31 (0)40 2668620

Asia Pacific

F +31 (0)40 2668615

A Office No. 1 on 12/F, Shatin Galleria

18-24 Shan Mei Street

Fotan, Shatin, Hong Kong

P 852 2145 4099

F 852 2145 4477

advertisement

Related manuals