Cautions
Disposal of the old air conditioner Safety Instructions and Warnings
Before disposing an old air conditioner that goes out of use, please make sure it's inoperative and safe. Unplug the air conditioner in order to avoid the risk of child entrapment.
It must be noticed that air conditioner system contains refrigerants, which require specialized waste disposal. The valuable materials contained in an air conditioner can be recycled
.Contact your local waste disposal center for proper disposal of an old air conditioner and contact your local authority or your dealer if you have any question. Please ensure that the pipework of your air conditioner does not get damagedprior to being picked up by the relevant waste disposal center, and contribute to environmental awareness by insisting on an appropriate, anti-pollution method of disposal.
Before starting the air conditioner, read the information given in the Operation manual carefully. The Operation manual contains very important observations relating to the assembly, operation and maintenance of the air conditioner.
The manufacturer does not accept responsibility for any damages that may arise due to non-observation of the following instruction.
Damaged air conditioners are not to be put into operation. In case of doubt, consult your supplier.
Use of the air conditioner is to be carried out in strict compliance with the relative instructions set forth in the Operation manual .
Installation shall be done by professional people, don't install unit by yourself.
Disposal of the packaging of your new air conditioner
For the purpose of the safety,the air conditioner must be properly grounded in accordance with specifications.
All the packaging materials employed in the package of your new air conditioner may be disposed without any danger to the environment.
Always remember to unplug the air conditioner before openning inlet grill. Never unplug your air conditioner by pulling on the power cord. Always grip plug firmly and pull straight out from the outlet.
The cardboard box may be broken or cut into smaller pieces and given to a waste paper disposal service. The wrapping bag made of polyethylene and the polyethylene foam pads contain no fluorochloric hydrocarbon.
Consult your local authorities for the name and address of the waste materials collecting centers and waste paper disposal services nearest to your house.
All electrical repairs must be carried out by qualified electricians. Inadequate repairs may result in a major source of danger for the user of the air conditioner.
All these valuable materials may be taken to a waste collecting center and used again after adequate recycling.
Do not damage any parts of the air conditioner that carry refrigerant by piercing or performating the air conditioner's tubes with sharp or pointed items, crushing or twisting any tubes, or scraping the coatings off the surfaces. If the refrigerant spurts out and gets into eyes, it may result in serious eye injuries.
1
Cautions
Do not obstruct or cover the ventilation grille of the air conditoner.Do not put fingers or any other things into the inlet/outlet and swing louver.
7. The appliance is not intended for use
by young children or infirm persons
without supervision.
Do not allow children to play with the air
conditioner.In no case should children be allowed to sit on the outdoor unit.
8. Young children should be supervised
to ensure that they do not play with
the applience.
9.Please employ the proper power plug,
which fit into the power supply cord.
Specifications
10 .The power plug and connecting cable
must have acquired the local attestation.
The refrigerating circuit is leak-proof.
The machine is adaptive in following situation
11.In order to protect the units,please turn
off the A/C first, and at least 30 seconds
later, cutting off the power.
1.Applicable ambient temperature range:
Maximum:D.B/W.B 32 o
C/23 o
C
Indoor
Minimum:D.B/W.B
18 o
C/14 o
C
Cooling
Outdoor
Maximum:D.B/W.B
Minimum:D.B
43 o
C/26 o
C
18 o
C
12. For model HSU-22HV04/R2(DB) , the
breaker of the air conditioner should
be an air gap contact. Such means
for disconnection must be incorporation
in the fixed wiring according to the
wiring rules.
Indoor
Maximum:D.B
Minimum:D.B
27 o
C
15 o
C
Heating
Outdoor
Maximum:D.B/W.B
24 o
C/18 o
C
Minimum:D.B/W.B
-15 o
C
2. If the power supply cord is damaged, it
must be replaced by the manufacturer
or its service agent or a similar qualified
person.
3. If the fuse of indoor unit on PC board is
broken,please change it with the type of
T. 3.15A/ 250V. If the fuse of outdoor
unit is broken,change it with the type of
T.25A/250V
4. The wiring method should be in line with
the local wiring standard.
5. After installation, the power plug should
be easily reached.
6. The waste battery should be disposed
properly.
2
Cautions
Safety Instruction
Please read the following Safety Instructions carefully prior to use.
The instructions are classified into two levels, WARNING and CAUTION according to the seriousness of possible risks and damages as follows. Compliance to the instructions are strictly required for safety use.
Installation
WARNING
Please call Sales/Service Shop for the Installation.
Do not attempt to install the air conditioner by yourself because improper works may cause electric shock, fire, water leakage.
lnstallation in a inadequate place may cause accidents. Do not install in the following place.
CAUTION
Connect the earth cable.
Do not install in the place where there is any possibility of inflammable gas
leakage around the
unit.
Do not get the unit exposed to vapor or oil steam.
earthing
Check proper installation of the drainage securely
PROHIBITION PROHIBITION
STRICT
ENFORCEMENT
3
Cautions
When abnormality such as burnt-small found,
immediately stop the operation button and contact sales shop.
WARNING
Use an exclusive power source with a circuit breaker
OFF
Connect power supply cord to the outlet completely
STRICT
ENFORCEMENT
Use the proper voltage
Do not use power supply cord
extended or connected in halfway
STRICT
ENFORCEMENT
Do not use power supply cord in a bundle.
STRICT
ENFORCEMENT
Take care not to damage the power supply cord.
PROHIBITION
Do not insert objects into the air inlet or outlet.
PROHIBITION
Do not start or stop the operation by disconnecting the power supply cord and so on.
PROHIBITION
Do not channel the air flow directly at people, especially at infants or the aged.
PROHIBITION
Do not try to repair or reconstruct by yourself.
PROHIBITION PROHIBITION
Do not use for the purpose of storage of food, art work, precise equipment, breeding, or cultivation.
CAUTION
Take fresh air occasionally especially when gas appliance is running at the same time.
Do not operate the switch with wet hand.
PROHIBITION
Do not install the unit near a fireplace or other heating apparatus.
Check good condition of the installation stand
STRICT
ENFORCEMENT PROHIBITION
Do not pour water onto the unit for cleaning
PROHIBITION
Do not place animals or plants in the direct path of the air flow
PROHIBITION
Do not place any objects on or climb on the unit.
PROHIBITION
Do not place flower vase or water containers on the top of the unit.
PROHIBITION
4
PROHIBITION PROHIBITION
Parts and Functions
Indoor unit
Outlet
Air filter(inside)
Display board
Inlet
Air Purifying Filter
(inside)
Inlet grille
Vertical flap
(adjust up and down air flow.
Don't adjust it manually)
Horizontal louver
(adjust left and right air flow)
Negative ion generator
(inside)
Power plug
Outdoor unit
HSU-09HV04/R2(DB)
HSU-12HV04/R2(DB)
HSU-18HV04/R2(DB) HSU-22HV04/R2(DB)
1
2
OUTLET
INLET
3
CONNECTING PIPING AND ELECTRICAL WIRING
4 DRAIN HOSE
5
Parts and Functions
16 31 10 14 21 15
19
28
30
1.RESET
When the remote controller appears abnormal,
use a sharp pointed article to press this button
to reset the remote controller normal.
2.LIGHT button
Control the lightening and extinguishing of the indoor LCD display board.
3. TIMER button
Used to select TIMER ON, TIMER OFF,
TIMER ON-OFF.
4. CLOCK button
Used to set correct time.
5. SLEEP button
Used to select sleep mode.
6. MODE button
AUTO COOL DRY FAN HEAT
7. HOUR button
Used to set clock and timer setting.
8. HEALTH button
Used to set healthy operation.
9. ON/OFF button
Used for unit start and stop.
10. TIMER ON display
11. FAN SPEED display
LOW MED HI
12. LOCK display
13. SWING UP/DOWN display
14. SLEEP display
15. HEALTH display
16. Operation mode display
Operation mode
AUTO COOL DRY
AUTO
HEAT FAN
Remote controller
Display board
17.Singal sending display
18. POWER/SOFT display
19. Left/right air flow display
20. TEMP display
Remote controller: to display the TEMP. setting.
21. TIMER OFF display
22. TIMER display
23. TEMP button
Used to select your desired temperature.
24. FAN button
Used to select fan speed: LOW,MED, HI, AUTO.
25. HEALTH AIRFLOW button
Used to set the health airflow mode.
26. SWING UP/DOWN button
Used to select up or down air sending direction.
27. SWING LEFT/RIGHT button
Used to select left/right air flow.
28. SET button
Used to confirm timer and clock settings.
29. POWER/SOFT button
Every time the button is pressed,display changes as follows: BLANK
POWER SOFT
30. LOCK
Used to lock buttons and LCD display. If pressed, the other buttons will be disabled and the lock condition display appears. Press it once again, lock will be canceled and lock condition display disappears.
31. Ambient temp.display
When receiving the remote control signal, display the set temperature and in the rest time the room temperature is displayed and this room temperature is only for reference.
NOTE:Cooling only unit do not have functions and displays related with heating.
6
Parts and Functions
Clock Set
When unit is started for the first time and after replacing batteries in remote controller, clock should be adjusted as follows:
1. Press CLOCK button,"AM" or "PM" flashes.
2. Press or to set correct time. Each press will increase or decrease
1 min. If the button is kept depressed, time will change quickly.
3. After time setting is confirmed, press SET, "AM" or "PM" stop flashing,
while clock starts working.
POWER/SOFT
Remote controller's operation
When in use, put the signal transmission head directly to the receiver hole on the indoor unit.
The distance between the signal transmission head and the receiver hole should be within
7m without any obstacle as well.
Don't throw or knock the remoter controller.
When electronic-started type fluorescent lamp or change-over type fluorescent lamp or wireless telephone is installed in the room, the receiver is apt to be disturbed in receiving the signals, so the distance to the indoor unit should be shorter.
Loading of the battery
Load the batteries as illustrated right
2 R-03 (7#) batteries
Remove the battery cover:
Slightly press" "area and push down the cover as illustrated.
Load the battery:
Be sure that the loading is in line with the "+" / "-".
request as illustrated on the bottom of the case.
Put on the cover again.
Confirmation indicator:
After pressing power ON/OFF, if no display, reload the batteries.
Note:
Full display or unclear display during operation indicates the batteries have been used up.
Please change batteries.
Used two new same-typed batteries when loading.
If the remote controller can't run normally during operation, please remove the batteries and
reload several minutes later.
Hint:
Remove the batteries in case unit won't be in usage for a long period. If there are any display after taking-out, just need to press reset key.
7
Operation
HEALTH operation
Remote controller
1.Unit start
Press ON/OFF on the remote controller, unit starts.
POWER/SOFT
2.Health negative ion function
Press HEALTH button. For each press, is displayed.
Air conditioner starts health negative ion function operation.
For twice press, disappears,the operation stops.
When indoor fan motor is running, it has healthy process function. (It's available under any mode)
When the fan motor in the indoor unit does not work, the health lamp lights up, but the negative ion generator does not release negative ion.
BRIEF INTRODUCTION TO HEALTH ION FUNCTION
The negative ion generator in the air conditioner can generate a lot of negative ion, effectively balancing the quantity of negative ion in the air and also kills the bacteria and speeds up the dust sediment removal in the room and finally cleans the air in the room.
8
Operation
Auto Operation
Remote controller
POWER/SOFT
1. Unit start
Press ON/OFF on the remote controller, unit starts.
2.Select operation mode
Press MODE button. For each press, operation mode changes as follows:
Remote controller:
AUTO COOL DRY FAN HEAT
Then Select Auto operation
On the displaying board,colorful displaying bar will be white.
3.Fan speed selection
Press FAN button. For each press, fan speed changes as follows:
Remote controller:
LOW MED HI AUTO
Air conditioner is running under displayed fan speed.
When FAN is set to AUTO, the air conditioner automatically adjusts the fan speed according to room temperature.
4.Unit stop
Press ON/OFF button, the unit stops.
About Auto Operation
Under the mode of auto operation, air conditioner will automatically select Cool or Heat operation according to room temperature.
9
Operation
Cool Operation
Remote controller
POWER/SOFT
1. Unit start
Press ON/OFF on the remote controller, unit starts.
2.Select operation mode
Press MODE button. For each press, operation mode changes as follows:
Remote controller:
AUTO COOL DRY FAN HEAT
Then Select COOL operation
On the displaying board,colorful displaying bar will be blue.
3.Select temp.setting
Press TEMP. button
Every time the button is pressed, temp.setting
increase 1 o
C,if kept depressed, it will increase rapidly
Every time the button is pressed, temp.setting
decrease 1 o
C,if kept depressed, it will decrease rapidly
Select a desired temperature.
4.Fan speed selection
Press FAN button. For each press, fan speed changes as follows:
Remote controller:
LOW MED HI AUTO
Air conditioner is running under displayed fan speed.
When FAN is set to AUTO, the air conditioner automatically adjusts the fan speed according to room temperature.
5.Unit stop
Press ON/OFF button, the unit stops.
10
Operation
Dry Operation
Remote controller
POWER/SOFT
1. Unit start
Press ON/OFF on the remote controller, unit starts.
2.Select operation mode
Press MODE button. For each press, operation mode changes as follows:
Remote controller:
AUTO COOL DRY FAN HEAT
Then Select DRY operation
On the displaying board,colorful displaying bar will be light blue
3.Select temp.setting
Press TEMP. button
Every time the button is pressed, temp.setting
increase 1 o
C,if kept depressed, it will increase rapidly
Every time the button is pressed, temp.setting
decrease 1 o
C,if kept depressed, it will decrease rapidly
Select a desired temperature.
4.Fan speed selection
Press FAN button. For each press, fan speed changes as follows:
Remote controller:
LOW MED HI AUTO
Air conditioner is running under displayed fan speed.
In DRY mode, when room temperature becomes 2
O
C higher than temp.setting,unit will run intermittently at
LOW speed regardless of FAN setting.
5.Unit stop
Press ON/OFF button, the unit stops.
11
Operation
Fan Operation
Remote controller
POWER/SOFT
1. Unit start
Press ON/OFF on the remote controller, unit starts.
2.Select operation mode
Press MODE button. For each press, operation mode changes as follows:
Remote controller:
AUTO COOL DRY FAN HEAT
Then Select FAN operation
On the displaying board,colorful displaying bar will be pink.
3.Fan speed selection
Press FAN button. For each press, fan speed changes as follows:
Remote controller:
LOW MED
4.Unit stop
Press ON/OFF button, the unit stops.
HI
About FAN operation
In FAN operation mode, the unit will not operate in
COOL or HEAT mode but only in FAN mode ,AUTO is not available in FAN mode.And temp.setting is disabled.
In FAN mode,SLEEP and POWER/SOFT operation is not available.
12
Operation
Heat Operation
Remote controller
POWER/SOFT
1. Unit start
Press ON/OFF on the remote controller, unit starts.
2.Select operation mode
Press MODE button. For each press, operation mode changes as follows:
Remote controller:
AUTO COOL DRY FAN HEAT
Then Select HEAT operation
On the displaying board,colorful displaying bar will be red
3.Select temp.setting
Press TEMP. button
Every time the button is pressed, temp.setting
increase 1 o
C,if kept depressed, it will increase rapidly
Every time the button is pressed, temp.setting
decrease 1 o
C,if kept depressed, it will decrease rapidly
Select a desired temperature.
4.Fan speed selection
Press FAN button. For each press, fan speed changes as follows:
Remote controller:
LOW MED HI AUTO
Air conditioner is running under displayed fan speed
IN HEAT mode, warm air will blow out after a short period of the time due to cold-draft prevention function.
When FAN is set to AUTO, the air conditioner automatically adjusts the fan speed according to room temperature.
5.Unit stop
Press ON/OFF button, the unit stops.
13
Operation
Air Flow Direction Adjustment
1.Status display of air sending
POWER/SOFT
Vertical flap
Pos.1
Pos.2
Pos.3
Pos.4
Pos.5
Pos.6
(Auto swing)
Horizontal louvers
Pos.1
Pos.2
Pos.3
Pos.4
Pos.5
Pos.6
Pos.7
Pos.8
2.Up and down air flow direction
For each press of button, air flow direction on remote controller displays as follows according to different operation modes:
COOL/DRY/FAN
Pos.1
Pos.2
Pos.3
Pos.4
Pos.6
HEAT: remote controller: Pos.5
Pos.4
Pos.3
Pos.2
Pos.1
Pos.6
AUTO: remote controller: Pos.1
Pos.2
Pos.3
Pos.4
Pos.5
Pos.6
The vertical flap will swing according to the above positions
3.Left and right air flow direction
For each press of button, remote controller displays as follows : remote controller:
Pos.1
Pos.2
Pos.3
Pos.4
Pos.5
Pos.6
Pos.7
Pos.8
The horizontal louvers will swing according to the above positions.
Note:When restart after remote turning off, the remote controller will automatically
memorize the previous set swing position.
14
Operation
Sleep Operation
Before going to bed, you can simply press the
SLEEP button and unit will operate in SLEEP mode and bring you a sound sleep.
Use of SLEEP function
After the unit starts, set the operation status, then press SLEEP button before which the clock must be adjusted and time being set.
Operation Mode
1. In COOL,DRY mode
1 hours after SLEEP mode starts, temp. will
become 1
O
C higher than temp. setting. After
another 1 hours, temp. rises by 1
O
C further.
The unit will run for further 6 hours then stops.
Temp. is higher than temp. setting so that room
temperature won't be too Iow for your sleep.
Remote Controller
POWER/SOFT
SLEEP operation starts SLEEP operation stops
Approx.6hrs
1 hr
1 hr
Rises 1
Rises 1
O
C
O
C
Temp.setting
In COOL, DRY mode
Unit stop
2.
In HEAT mode
1 hours after SLEEP mode starts, temp will become 2
O
C lower than temp.
setting. After another 1 hours, temp decrease by 2
O
C further. After more another 3 hours, temp. rises by 1
O
C further. The unit will run for further 3 hours then stops. Temp. is lower than temp. setting so that room temperature won't be too high for your sleep.
Temp.setting
Unit stop
1 hr
1 hr
Decreases 2
O
C
Decreases 2
O
C
3 hrs
3 hrs
Rises 1
O
C
SLEEP operation starts
In HEAT mode
SLEEP operation stops
3.
In AUTO mode
The unit operates in corresponding sleep mode adapted to the automatically selected operation mode.
4. In FAN mode
It has no SLEEP function.
5.Set the wind speed change when sleeping
If the wind speed is high or middle before setting for the sleep, set for lowing the wind speed after sleeping.
If it is low wind, no change.
6.Note to the power failure resume:
press the sleep button ten times in five seconds
and enter this function after hearing four sounds.
And press the sleep button ten times within five
seconds and leave this function after hearing
two sounds.
NOTE: With the power failure resume, when setting the TIMER ON, TIMER OFF and TIMER ON/OFF, itís memorized as shutdown status when resuming after power out.
15
Operation
Timer On/Off Operation
Remote Controller
Set clock correctly before starting TIMER operation.
1. After unit starts, select your desired operation mode
Operation mode will be displayed on LCD.
2. Timer mode selection
Press TIMER button to change TIMER mode. Every
time the button is pressed, display changes as follows:
Remote controller:
BLANK
TIMER ON TIMER OFF TIMER ON-OFF
POWER/SOFT
Then select your desired TIMER mode (TIMER ON or
TIMER OFF). " "or " "will flash.
3.Time setting
Press HOUR button.
Every time the button is pressed, time setting
increases 1 min, if kept depressed, it will increase
rapidly.
Every time the button is pressed, time setting
decreases 1 min, if kept depressed, it will decrease
rapidly.
It can be adjusted within 24 hours.
4.Confirming your setting
After setting correct time, press SET button to confirm
" "or" "on the remote controller stops flashing.
Time displayed: Unit starts or stops at x hour x min.
(TIMER ON or TIMER OFF).
5.Cancel TIMER mode
Just press TIMER button several times until TIMER mode disappears.
Hints:
After replacing batteries or a power failure happens, time setting should be reset.
Remote controller possesses memory function, when use TIMER mode next time,
just press SET button after mode selecting if time setting is the same as previous one.
16
Operation
Timer On-Off Operation
Remote Controller
POWER/SOFT
Set clock correctly before starting TIMER operation.
1. After unit starts, select your desired operation mode
Operation mode will be displayed on LCD.
2. Timer mode selection
Press TIMER button to change TIMER mode. Every time
the button is pressed, display changes as follows:
Remote controller:
BLANK
TIMER ON TIMER OFF TIMER ON-OFF
Then select your desired TIMER mode (TIMER ON - OFF).
" "will flash.
3.Time setting
Press HOUR button.
Every time the button is pressed, time setting increases
1 min, if kept depressed, it will increase rapidly.
Every time the button is pressed, time setting decreases
1 min, if kept depressed, it will decrease rapidly.
It can be adjusted within 24 hours.
4.Timer confirming for TIMER ON
After setting correct time, press TIMER button to confirm
" " on the remote controller stops flashing.
" " starts flashing.
Time displayed: Unit starts or stops at x hour x min.
5.Time setting for TIMER OFF
Just press HOUR button ,follow the same procedure in
"Time setting for TIMER ON"
6.Time confirming for TIMER OFF
After time setting,press SET button to confirm.
" " on the remote controller stops blinking.
Time displayed:Unit stops at x hour x min.
To cancel TIMER mode
Just press TIMER button several times until TIMER
de disappears.
According to the Time setting sequence of TIMER ON or TIMER OFF, either Start-Stop or Stop-Start can be achieved.
17
Operation
POWER/SOFT Operation
POWER Operation
When you need rapid heating or cooling, you can use this funciton.
Selecting of POWER operation
Press POWER/SOFT button. Every time the button is pressed,display changes as follows:
BLANK
POWER SOFT
Stop the display at
In POWER operation status:
In HEAT or COOL mode, fan speed automatically runs in AUTO mode for 15 min then returns to original status setting.
To cancel POWER operation
Press POWER/SOFT button twice ,POWER/SOFT disappears.
SOFT Operation
You can use this function when silence is needed for rest or reading.
Selecting of SOFT operation
Press POWER/SOFT button. Every time the button is pressed,display changes as follows:
BLANK
POWER SOFT
Stop the display at
In SOFT operation mode, fan speed automatically takes"AUTO"
To cancel SOFT operation
Press POWER/SOFT button twice ,POWER/SOFT disappears.
Hints:
During POWER operation, in rapid HEAT or COOL mode, the room
will show inhomogeneous temperature distribution.
Long period SOFT operation will cause effect of not too cool
or not too warm.
18
Operation
Health airflow Operation
Remote controller
POWER/SOFT
1.Press ON/OFF to starting
The liquid crystal will display the working state of last time
(Except timer, sleeping, power/soft and health airflow).
Setting the comfort work conditions.
2.The setting of health airflow function
1).Press the button of health airflow, appears on the display. The bottom inlet and outlet grills of the air conditioner are closed and the airflow is blown horizontally from the above inlet and outlet grills. Avoid the strong airflow blows direct to the body.
2).Press the button of health airflow again, appears on the display. The above inlet and outlet grills of the air conditioner are closed and the airflow is blown vertically from the bottom inlet and outlet grills. Avoid the strong airflow blows direct to the body.
3.The cancel of the health airflow function
Press the button of health airflow again, both the inlet and outlet grills of the air conditioner are opened, and the unit goes on working under the condition before the setting of health airflow function.
After stopping, the outlet grille will close automatically.
Notice: Cannot pull direct the outlet grille by hand. Otherwise, the grille will run incorrectly. If the grille is not run correctly, stop for a minute and then start, adjusting by remote controller.
Note:
1 .After setting the health airflow function, the position of inlet and outlet grills is fixed.
2.In heating, it is better to select the mode.
3.In cooling, it is better to select the mode.
4.In cooling and dry, using the air conditioner for a long time under the high air humidity, a phenomenon falling drips of water occurs at the outlet grille .
5.Select the appropriate fan direction according to the actual conditions.
19
Operation
Emergency and Test Operation
Emergency operation:
Use this operation only when the remote controller
is defective or lost.
When the emergency operation switch is pressed,the" Pi "sound is heard once, which means the start of this operation.
In this operation, the system automatically selects the operation modes, cooling or heating, according to the room temperature.
Temperature
Operation
mode
Designated temperature
Timer mode
Air flow
ABOVE 23
O
C COOLING 26
O
C NO
BELOW 23
O
C HEATING 23
O
C NO
It is not possible to operate in dry mode.
AUTOMATIC
AUTOMATIC
Test operation:
Test operation switch is the same as emergency switch.
Use this switch in the test operation when the room temperature is below 16
O
C, do not use it in the normal operation.
Continue to press the test operation switch for more
than 5 seconds. After you hear the "Pi" sound twice,
release your finger from the switch: the cooling operation
starts with the air flow speed "Hi".
After 30 minutes, test operation ends automatically.
Removal of the restriction of emergency or test operation
Press the emergency operation switch once more, or manipulate through the
remote controller; the "Pi" sound, the emergency or test operation is terminated.
When the remote controller is manipulated, it gets the system back to the
normal operation mode.
20
Maintenance
For Smart Use of The Air Conditioner
Setting of proper room temperature
Do not block the air inlet or outlet
Proper temperature
Close doors and windows during operation
Use the timer effectively
During cooling operation prevent the penetration of direct sunlight with curtain or blind
If the unit is not to be used for a long time, turn off the power supply main switch.
Use the louvers effectively
OFF
21
Maintenance
For Smart Use of The Air Conditioner
WARNING
Before maintenance,be sure to turn off the system and the circuit breaker.
Remote Controller Indoor Body
Do not use water, wipe the controller with a dry cloth.Do not use glass cleaner or chemical cloth.
Wipe the air conditioner by using a soft and dry cloth.For serious stains,use a neutral detergent diluted with water.Wring the water out of the cloth before wiping.then wipe off the detergent completely.
Do not use the following for cleaning
Gasoline,benzine, thinner or cleanser may damage the coating of the unit.
Hot water over 40
O
C(104
O
F) may cause discoloring or deformation.
Air Filter cleaning
Open the inlet grille by pulling it upward.
Remove the filter.
Push up the filter's center tab slightly until it is released from the stopper, and remove the filter downward.
Clean the filter.
Use a vacuum cleaner to remove dust, or wash the filter with water.After washing, dry the filter completely in the shade.
Attach the filter.
Attach the filter correctly so that the "FRONT" indication is facing to the front.Make sure that the filter is completely fixed behind the stopper.If the right and left filters are not attached correctly, that may cause defects.
Close the inlet grille.
Once every two weeks
22
Maintenance
Replancement of Air Purifying Filter
1.Open the lnlet Grille
Open the inlet grille by pushing each ends of the inlet grille upward.(use thumbs to push up)
2.Detach the standard air filter
Slide the knob slightly upward to release the filter, then withdraw it.
3.Attach old Air Purifying Filter
Put air purifying filter appliances into the right and left filter frames.
Detach old Air Purifying Filter
4.Attach the standard air filter
(Necessary installation)
5.Close the Inlet Grille
Close the Grille surely
Note: the bacteria-killing mediums placed on the left side. the multi-lights touching intermediary is placed on the right side.
NOTE:
The photocatalyst air purifying filter and the bacteria-killing medium air purifying filter will be used based on real situation.
The photocatalyst air purifying filter will be solarized in fixed time. In normal family, it will be solarized every 6 months. The solarization time will last no less than 8 hours under the state of abundant sun.
The bacteria-killing medium air purifying filter is available for a long time and neednít to be changed. But it must be noticed to use the vacuum cleaner frequently to adsorb the dusts covering the purifying filter lest the covering dusts effect the function of the bacteria-killing medium air purifying filter. (It is strictly prohibited for the bacteria-killing medium air purifying filter to be washed)
23
Maintenance
To Keep Your Air conditioner in Good Condition after Season.
Operate in cooling mode for 2-3 hours.
To prevent breeding mold or bad smell, be sure to operate at the designated temperature or 30
O
C,cooling mode and High speed fan mode for 2-3 hours.
Put off the power supply cord.
Cleaning the body.
Take out the batteries from the wireless remote controller.
24
Maintenance
Before Setting in High season
Cleaning the standard air filter.
Operation without filter may cause troubles.Be sure to attach both right and left filters prior to the operation.
Each of them are of different shapes.
Connecting the earthing cable.
Caution
Incomplete earthing may cause an electric shock.
Do not block the air inlet or outlet.
EARTHING
Plug-in
Caution
After brush away dust at the plug, insert the plug of the power supply cord into the outlet completely.In case of suing exclusive circuit breaker,switch on the circuit breaker.
25
NO WET HAND
Trouble shooting
Before asking for service, check the following first.
Normal
Performance inspection
Phenomenon
The system does not restart immediately.
Noise is heard:
Smells are generated.
Mist or steam are blown out.
Cause or check points
When unit is stopped, it won't restart immediately until 3 minutes have elapsed to protect the system.
When the electric plug is pulled out and reinserted, the protection circuit will work for 3 minutes to protect the air conditioner.
During unit operation or at stop, a swishing or gurgling noise may be heard. At first 2-3 minutes after unit start, this noise is more noticeable. (This noise is generated by refrigerant flowing in the system.)
During unit operation, a cracking noise may be heard. This noise is generated by the casing expanding or shrinking because of temperature changes.
Should there be a big noise from air flow in unit operation, air filter may be too dirty.
This is because the system circulates smells from the interior air such as the smell of furniture, cigarettes.
During COOL or DRY operation, indoor unit may blow out mist. This is due to the sudden cooling of indoor air.
Multiple check
Does not work at all.
Poor cooling
Is power plug inserted?
Is there a power failure?
Is fuse blown out?
Is the air filter dirty? Normally it should be cleaned every 15 days.
Are there any obstacles before inlet and outlet?
Is temperature set correctly?
Are there some doors or windows left open?
Is there any direct sunlight through the window during the cooling operation?(Use curtain)
Are there too much heat sources or too many people in the room during cooling operation?