C H A P T E R 1
General Guidelines for Pod Management 2
Identifying the Install Directory 4
Managing Hosts in Cisco VIM or NFVI Pods 4
Managing Nova Compute Scheduler Filters and User Data 8
Utilizing NUMA in Cisco NFV Infrastructure 9
Monitoring Cisco NFVI Health with CloudPulse 10
Assessing Cisco NFVI status with cloud-sanity 12
Get Service Catalog URL for Cloudpulse 15
Get detailed result of 1 test 16
Get List of Tests Available 17
Schedule a manual cloudpulse test: 17
Remove the results of a test 18
Checking Network Connections 18
Enabling NFVBench Post Deployment 19
NFVBench Command Line Options 24
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2 iii
Contents
C H A P T E R 2
C H A P T E R 3
C H A P T E R 4
NFVBench Result Generation and Storage 26
Enabling or Disabling Autobackup of Management Node 32
Forwarding ELK logs to External Syslog Server 33
Adding and Reconfiguring VIM Administrators 33
Reconfigure of Proxy Post Install 34
Updating Containers in a Running Cisco VIM Cloud 35
Updating Cisco VIM Software Using a USB 36
Updating Cisco VIM Software Using Network Installation 38
Upgrading Containers in a Running Cisco VIM Cloud 38
Upgrading VIM Software Using a USB 41
Upgrading Cisco VIM Software Using Network Installation 44
Overview to Cisco VIM REST API 47
Cisco VIM REST API Resources 48
Monitoring Cisco NFVI Performance 81
Logging and Monitoring in Cisco NFVI 81
Displaying Cisco VIM Log Files Using the CLI 84
Logging Into the Kibana Dashboard 85
Rotation of the Cisco VIM Logs 94
Network Performance Test with NFVBench 94
Managing Cisco NFVI Security 95
Verifying Management Node Network Permissions 95
Verifying Management Node File Permissions 96
Viewing Administrator Access Attempts 96
iv
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
Contents
C H A P T E R 5
Validating Port Listening Services 97
Validating Non-Root Users for OpenStack Services 98
Verifying Password Strength 98
Reconfiguring Passwords and OpenStack Configurations 99
Reconfiguring CIMC Password on an Existing Install 102
Increasing Provider and Tenant VLAN Ranges 103
Enabling NFVIMON Post Pod Install 103
Installation of NFVIMON Dispatcher 104
Reconfiguring TLS Certificates 107
Enabling Keystone v3 on an Existing Install 108
LDAP/AD support with Keystone v3 108
Managing Cisco NFVI Storage 111
Cisco NFVI Storage Architecture 111
Verifying and Displaying Ceph Storage Pools 112
Checking the Storage Cluster Health 113
Checking Glance Connectivity 114
Verifying Glance and Ceph Monitor Keyrings 115
Verifying Glance Image ID on Ceph 116
Checking Cinder Connectivity 116
Verifying the Cinder and Ceph Monitor Keyrings 117
Verifying the Cinder Volume ID on Ceph 118
Checking Nova Connectivity 118
Verifying the Nova and Ceph Monitor Keyrings 119
Verifying Nova Instance ID 120
Displaying Docker Disk Space Usage 121
Reconfiguring SwiftStack Integration 121
Integrating SwiftStack over TLS 122
Cinder Volume Backup on SwiftStack 122
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2 v
Contents
C H A P T E R 6
C H A P T E R 7
C H A P T E R 8
Reconfiguring Administrator Source Networks 123
Password Reset for Cisco VIM Management Node 123
Overview to Cisco VIM Insight 125
Cisco VIM Insight Overview 125
Cisco VIM Insight Admin UI Overview 127
Cisco VIM Insight Pod UI Overview 127
Managing Cisco VIM through Insight 129
UI Administrators Privileges and Responsibilities 129
Pod UI Privileges and Responsibilities 130
Deleting Pod from Cisco VIM insight 131
Context Switching within Insight 132
Creating a Blueprint for B-Series Server Platform 134
Creating a Blueprint for C-Series Server Platform 149
Creating a Blueprint using Upload Functionality 165
Activating a Blueprint in an Existing Pod with OpenStack Installed 166
Managing Post Install Features 168
Reconfiguring CIMC Password through Insight 171
vi
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
Contents
C H A P T E R 9
C H A P T E R 1 0
Managing Pod Through Cisco VIM Insight 173
Reconfiguring CIMC Password 180
Reconfigure OpenStack Services, TLS Certificates and ELK Configurations 181
Reconfiguring CIMC Password 181
Reconfigure Optional Services 182
Reconfiguring Optional Features through Insight 184
Managing Root CA Certificate 197
Day 2 Operations of Cisco VIM Insight 199
Shutting Down Cisco VIM Insight 199
Restarting Cisco VIM Insight 200
Reconfiguring Insight TLS Certificate 203
Reconfigure 3rd Party TLS Certificate 203
Reconfigure Self Signed TLS Certificate 205
Switch from Self Signed TLS Certificate to 3rd Party TLS Certificate 207
Reconfiguring Insight MySQL Database Password 209
System generated Insight DB password 209
User supplied Insight DB password 211
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2 vii
Contents
C H A P T E R 1 1
C H A P T E R 1 2
C H A P T E R 1 3
Reconfigure Insight SMTP Server 212
Update VIM Insight with Internet Access 215
VIM Insight without Internet Access 216
Overview to the Cisco Virtual Topology System 223
Cisco VTS Architecture Overview 224
Virtual Topology Forwarder 225
Overview to Cisco VTF and VPP 225
Virtual Topology System High Availability 227
Managing Backup and Restore Operations 229
Managing Backup and Restore Operations 229
Backing up the Management Node 229
Backup with Forwarding ELK logs to External Syslog Server 231
Backup Insight at default backup location 234
Backup Insight at user defined backup location 235
Restoring the Management Node 236
Management Node Auto-backup 238
Displaying Cisco NFVI Node Names and IP Addresses 241
Verifying Cisco NFVI Node Interface Configurations 242
Displaying Cisco NFVI Node Network Configuration Files 244
Viewing Cisco NFVI Node Interface Bond Configuration Files 244
Viewing Cisco NFVI Node Route Information 245
Viewing Linux Network Namespace Route Information 246
Prior to Remove Storage Operation 246
viii
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
Contents
Troubleshooting Cisco NFVI 247
Management Node Recovery Scenarios 249
Recovering Compute Node Scenario 257
Running the Cisco VIM Technical Support Tool 259
Tech-support configuration file 260
Tech-support when servers are offline 262
Disk-maintenance tool to manage HDDs 263
Utility to resolve Cisco VIM Hardware Validation Failures 273
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2 ix
Contents x
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
C H A P T E R
1
Managing Cisco NFVI
The following topics provide general management procedures that you can perform if your implementation is Cisco VIM by itself or is Cisco VIM and Cisco VIM Insight.
•
Managing Cisco NFVI Pods, page 2
•
Managing Nova Compute Scheduler Filters and User Data, page 8
•
Utilizing NUMA in Cisco NFV Infrastructure, page 9
•
Monitoring Cisco NFVI Health with CloudPulse, page 10
•
Assessing Cisco NFVI status with cloud-sanity, page 12
•
•
Checking Network Connections, page 18
•
Enabling NFVBench Post Deployment, page 19
•
•
Enabling or Disabling Autobackup of Management Node, page 32
•
Forwarding ELK logs to External Syslog Server, page 33
•
Adding and Reconfiguring VIM Administrators, page 33
•
Reconfigure of Proxy Post Install, page 34
•
Updating Containers in a Running Cisco VIM Cloud, page 35
•
Updating Cisco VIM Software Using a USB, page 36
•
Updating Cisco VIM Software Using Network Installation, page 38
•
Upgrading Containers in a Running Cisco VIM Cloud, page 38
•
Upgrading VIM Software Using a USB, page 41
•
Upgrading Cisco VIM Software Using Network Installation, page 44
•
•
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
1
Managing Cisco NFVI
Managing Cisco NFVI Pods
Managing Cisco NFVI Pods
You can perform OpenStack management operations on Cisco NFVI pods including addition and removal of
Cisco NFVI compute and Ceph nodes, and replacement of controller nodes. Each action is mutually exclusive.
Only one pod management action can be performed at any time. Before you perform a pod action, verify that the following requirements are met:
• The node is part of an existing pod.
• The node information exists in the setup_data.yaml file, if the pod management task is removal or replacement of a node.
• The node information does not exist in the setup_data.yaml file, if the pod management task is to add a node.
To perform pod actions, see the
Managing Hosts in Cisco VIM or NFVI Pods , on page 4
section.
General Guidelines for Pod Management
The setup_data.yaml file is the only user-generated configuration file that is used to install and manage the cloud. While many instances of pod management dictates that the setup_data.yaml file is modified, the administrator does not update the system generated setup_data.yaml file directly.
Note To avoid translation errors, we recommend that you avoid cutting and pasting commands from the documents to the Linux CLI.
To update the setup_data.yaml file, do the following:
1 Copy the setup data into a local directory
[root@mgmt1 ~]# cd /root/
[root@mgmt1 ~]# mkdir MyDir
[root@mgmt1 ~]# cd MyDir
[root@mgmt1 ~]# cp /root/openstack-configs/setup_data.yaml <my_setup_data.yaml>
2 Update the setup data manually.
[root@mgmt1 ~]# vi my_setup_data.yaml (update the targeted fields for the setup_data)
3 Run the reconfiguration command:
[root@mgmt1 ~]# ciscovim – -setupfile ~/MyDir/<my_setup_data.yaml>
<pod_management_action>
In Cisco VIM 2.2, you can edit and enable a selected set of options in the setup_data.yaml file using the reconfigure option. After installation, you can change the values of the feature parameters. But, Cisco VIM
2.2 does not support deconfiguring of the feature .
The following table summarizes the list of features that can be reconfigured after the installation of the pod.
2
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
Managing Cisco NFVI
General Guidelines for Pod Management
Features that can be enabled post pod deployment
Optional OpenStack Services
Comments
• Heat: OpenStack Orchestration Program.
• Keystone v3: Pod running Keystone v2 can be migrated to Keystone v3.
• LDAP: Works only with Keystone v3. Full or partial reconfiguration can be done. All attributes except domain is reconfigurable.
Pod Monitoring
• NFVIMON: Third party Monitoring from host to service level; Does need involvement and planning with Cisco Advance Services. Also, supports only Keystone v2 in VIM 2.2.
Export of EFK logs to External Syslog Server
Admin Source Networks
NFVBench
EFK settings
OpenStack service password
CIMC Password Reconfigure Post Install
SwiftStack Post Install
TENANT_VLAN_RANGES and
PROVIDER_VLAN_RANGES
Export Logs to External Syslog Server
Replace of Failed APIC Hosts and add more leaf nodes
Reduces single point of failure on management node and provides data aggregation.
White list filter for accessing management node admin service.
Tool to help measure cloud performance.
Management node needs a 10G Intel NIC (4x10G
710, or 2x10G 520 Intel NIC).
EFK rotation frequency and size.
Implemented for security reasons, so that OpenStack passwords can be reset on-demand.
Implemented for security reasons, so that CIMC passwords for C-series pod, can be reset on-demand.(New in 2.2)
Integration with third party Object-Store. SwiftStack install is done independent of VIM and ahead of time; only works with Keystone v2.
Ability to increase the tenant and provider VLAN ranges on a pod that is up and running. It gives the customer the flexibility in network planning.
Ability to offload the OpenStack logs to an external syslog server post-install.
Ability to replace Failed APIC Hosts, and add more leaf nodes to increase the fabric influence.
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
3
Managing Cisco NFVI
Identifying the Install Directory
Features that can be enabled post pod deployment
Auto backup of Management Node
Comments
Ability to enable/disable auto-backup of Management
Node.
VIM Admins Ability to configure non-root VIM Administrators.
EXTERNAL_LB_VIP_FQDN
EXTERNAL_LB_VIP_TLS http_proxy and/or https_proxy
Ability to enable TLS on external_vip through FQDN.
Ability to enable TLS on external_vip through an IP address.
Ability to reconfigure http and/or https proxy servers.
Identifying the Install Directory
If the administrator is using CLI to manage the pod, the administrator must know the directory where the pod is installed from(refer to installer directory). To identify the installer directory of a pod, execute the following commands:
[root@mgmt1 ~]# cd /root/
[root@mgmt1 ~]# ls – lrt | grep openstack-configs lrwxrwxrwx.
1 root root 38 Mar 12 21:33 openstack-configs ->
/root/installer-<tagid>/openstack-configs
From the output, you can understand that the OpenStack-configs is a symbolic link to the installer directory.
Verify that the REST API server is running from the same installer directory location, by executing the following command:
# cd installer-<tagid>/tools
#./restapi.py -a status
Status of the REST API Server: active (running) since Thu 2016-08-18 09:15:39 UTC; 9h ago
REST API launch directory: /root/installer-<tagid>/
Managing Hosts in Cisco VIM or NFVI Pods
To perform actions on the pod, run the commands specified in the following table. If you log in as root, manually change the directory to /root/installer-xxx to get to the correct working directory for these Cisco
NFVI pod commands.
4
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
Managing Cisco NFVI
Managing Hosts in Cisco VIM or NFVI Pods
Table 1: Cisco NFVI Pod Management
Action
Remove block_storage or compute node
Add block_storage or compute node
Steps Restrictions
1 Remove the node information from the
ROLES and SERVERS section of the setup_data.yaml file for the specific node.
2 Enter one of the following commands.
For compute nodes:
You can remove multiple compute nodes and only one storage at a time;
The pod must have a minimum of one compute and two storage nodes after the removal action.
In Cisco VIM the number of ceph OSD nodes can vary from 3 to 20. You can remove one OSD node at a time as part of the pod management.
ciscovim remove-computes
--setupfile
~/MyDir/my_setup_data.yaml
<"compute-1,compute-2">
For storage nodes: ciscovim remove-storage
--setupfile
~/MyDir/my_setup_data.yaml
<"storage-1">
Note On a micro-pod expanded with standalone computes, only the standalone compute nodes can be removed. Pod management operation for storage node is not supported for micro-pod. In hyper-converged mode, compute management operations are not supported for hyper-converged nodes.
1 Add the node information from the
ROLES and SERVERS section of the setup_data.yaml file for the specific node.
2 Enter one of the following commands.
For compute nodes: ciscovim add-computes
--setupfile
~/MyDir/my_setup_data.yaml
<"compute-1,compute-2">
For storage nodes: ciscovim add-storage --setupfile
~/MyDir/my_setup_data.yaml
<"storage-1">
You can add multiple compute nodes and only one storage node at a time.
The pod must have a minimum of one compute, and two storage nodes before the addition action.
In Cisco VIM the number of ceph OSD nodes can vary from 3 to 20. You can add one OSD node at a time as part of the pod management.
Note On a micro-pod expanded with standalone computes, only the standalone compute nodes can be added. Pod management operation for storage node is not supported for micro-pod. In hyper-converged mode, compute management operations are not supported for hyper-converged nodes.
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
5
Managing Cisco NFVI
Managing Hosts in Cisco VIM or NFVI Pods
Action
Replace controller node
Steps Restrictions
1 If the controller node is in a UCS
C-Series pod, update the CIMC info node in the SERVERS section of the setup_data.yaml file for the specific node ciscovim replace-controller
--setupfile
~/MyDir/my_setup_data.yaml
<"control-1">
You can replace only one controller node at a time. The pod can have a maximum of three controller nodes.
In Cisco VIM the replace controller node operation is supported in micro-pod.
2 For B-series only update the blade and chassis info
3 Enter the following command:
Note While replacing the controller node, the IP address and hostname are reused. So, do not update any other controller information other than CIMC access for C-series, and blade and chassis information for B-series. For micro-pod this operation is supported on the AIO
(all in one) nodes.
When you add a compute or storage node to a UCS C-Series pod, you can increase the management/provision address pool. Similarly, for a UCS B-Series pod, you can increase the Cisco IMC pool to provide routing space flexibility for pod networking. Along with server information, these are the only items you can change in the setup_data.yaml file after the pod is deployed. To make changes to the management or provisioning sections and/or CIMC (for UCS B-Series pods) network section, you must not change the existing address block as defined on day 0. You can add only to the existing information by adding new address pool block(s) of address pool as shown in the following example:
NETWORKING:
:
: networks:
vlan_id: 99 subnet: 172.31.231.0/25 gateway: 172.31.231.1
## 'pool' can be defined with single ip or a range of ip pool:
- 172.31.231.2, 172.31.231.5 → IP address pool on Day-0
- 172.31.231.7 to 172.31.231.12 → IP address pool ext. on Day-n
- 172.31.231.20
segments:
## CIMC IP allocation. Needs to be an external routable network
- cimc
vlan_id: 2001 subnet: 192.168.11.0/25 gateway: 192.168.11.1
## 'pool' can be defined with single ip or a range of ip pool:
- 192.168.11.2 to 192.168.11.5
→ IP address pool on Day-0
- 192.168.11.7 to 192.168.11.12
→ IP address pool on day-n
- 192.168.11.20
→ IP address pool on day-n segments:
## management and provision goes together
- management
:
- provision
:
The IP address pool is the only change allowed in the networking space of the specified networks management/provision and/or CIMC (for B-series). The overall network must have enough address space to
6
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
Managing Cisco NFVI
Recovering Cisco NFVI Pods accommodate for future enhancement on day-0. After making the changes to servers, roles, and the corresponding address pool, you can execute the add compute/storage CLI shown above to add new nodes to the pod.
Recovering Cisco NFVI Pods
This section describes the recovery processes for Cisco NFVI control node and the pod that is installed through
Cisco VIM. For recovery to succeed, a full Cisco VIM installation must have occurred in the past, and recovery is caused by failure of one or more of the controller services for example, Rabbit MQ, MariaDB, and other services. The management node must be up and running and all the nodes must be accessible through SSH without passwords from the management node. You can also use this procedure to recover from a planned shutdown or accidental power outage.
Cisco VIM supports the following control node recovery command:
# ciscovim cluster-recovery
The control node will recover after the network partition is resolved.
To make sure Nova services are good across compute nodes, execute the following command:
# source /root/openstack-configs/openrc
# nova service-list
To check for the overall cloud status, execute the following:
# cd installer-<tagid>/tools
# ./cloud_sanity.py -c all
In case of a complete pod outage, you must follow a sequence of steps to bring the pod back. The first step is to bring up the management node, and check that the management node containers are up (and not in exited state) using docker ps – a command. After you bring up the management node, bring up all the other pod nodes. Make sure every node is reachable through password-less SSH from the management node. Verify that no network IP changes have occurred. You can get the node SSH IP access information from
/root/openstack-config/mercury_servers_info.
Execute the following command sequence:
• Check the setup_data.yaml file and runtime consistency on the management node:
# cd /root/installer-<tagid>/tools
# ciscovim run --perform 1,3 -y
• Execute the cloud sanity command:
# cd/root/installer-<tagid>/tools
# ./cloud_sanity.py -c all
• Check the status of the REST API server and the corresponding directory where it is running:
# cd/root/installer-<tagid>/tools
#./restapi.py -a status
Status of the REST API Server: active (running) since Thu 2016-08-18 09:15:39 UTC; 9h ago
REST API launch directory: /root/installer-<tagid>/
• If the REST API server is not running from the right installer directory, execute the following to get it running from the correct directory:
# cd/root/installer-<tagid>/tools
#./restapi.py -a setup
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
7
Managing Cisco NFVI
Managing Nova Compute Scheduler Filters and User Data
Check if the REST API server is running from the correct target directory
#./restapi.py -a status
Status of the REST API Server: active (running) since Thu 2016-08-18 09:15:39 UTC; 9h ago
REST API launch directory: /root/new-installer-<tagid>/
• Verify Nova services are good across the compute nodes, execute the following command:
# source /root/openstack-configs/openrc
# nova service-list
If cloud-sanity fails, execute cluster-recovery (ciscovim cluster-recovery), then re-execute the cloud-sanity and nova service-list steps as listed above.
Recovery of compute and OSD nodes requires network connectivity and reboot so that they can be accessed using SSH without password from the management node. To shutdown, bring the pod down in the following sequence:
1 Shut down all VMs, then all the compute nodes.
2 Shut down all storage nodes serially.
3 Shut down all controllers one at a time.
4 Shut down the management node.
5 Shut down the networking gears.
Bring the nodes up in reverse order, that is, start with networking gears, then the management node, storage nodes, control nodes, and compute nodes. Make sure each node type is completely booted up before you move on to the next node type. Then validate the Cisco API server.
ciscovim run – perform 1,3 -y
After the pod is up, run the partition-recovery playbook (ciscovim partition-recovery) on the management node, which will determine the correct order to bring up the Galera cluster by commit ID and start the remaining downed services.
Validate if all the VMs are up (not in shutdown state). If any of the VMs are in down state, bring them UP using the horizon dashboard.
Managing Nova Compute Scheduler Filters and User Data
OpenStack Nova is an OpenStack component that provides on-demand access to compute resources by provisioning large networks of virtual machines (VMs). In addition to the standard Nova filters, Cisco VIM supports the following additional scheduler filters:
• ServerGroupAffinityFilter — Ensures that an instance is scheduled onto a host from a set of group hosts.
To use this filter, you must create a server group with an affinity policy and pass a scheduler hint using group as the key and the server group UUID as the value. Use the nova command-line tool and the
--hint flag. For example:
$ nova server-group-create --policy affinity group-1
$ nova boot --image IMAGE_ID --flavor 1 --hint group=SERVER_GROUP_UUID server-1
• ServerGroupAntiAffinityFilter — Ensures that each group instance is on a different host. To use this filter, you must create a server group with an anti-affinity policy and pass a scheduler hint, using group
8
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
Managing Cisco NFVI
Utilizing NUMA in Cisco NFV Infrastructure as the key and the server group UUID as the value. Use the nova command-line tool and the --hint flag.
For example:
$ nova server-group-create --policy anti-affinity group-1
$ nova boot --image IMAGE_ID --flavor 1 --hint group=SERVER_GROUP_UUID server-1
• SameHostFilter — Within an instance set, schedules one instance on the same host as another instance.
To use this filter, pass a scheduler hint using same_host as the key and a list of instance UUIDs as the value. Use the nova command-line tool and the --hint flag. For example:
$ nova boot --image IMAGE_ID --flavor 1 --hint same_host=INSTANCE_ID server-1
• DifferentHostFilter — Within an instance set, schedules one instance on a different host than another instance. To use this filter, pass a scheduler hint using different_host as the key and a list of instance
UUIDs as the value. The filter is the opposite of SameHostFilter. Use the nova command-line tool and the --hint flag. For example:
$ nova boot --image IMAGE_ID --flavor 1 --hint different_host=INSTANCE_ID server-1
In addition to scheduler filters, you can set up user data files for cloud application initializations. A user data file is a special key in the metadata service that holds a file that cloud-aware applications in the guest instance can access. For example, one application that uses user data is the cloud-init system, an open-source package that is available on various Linux distributions. The cloud-init system handles early cloud instance initializations.
The typical use case is to pass a shell script or a configuration file as user data during the Nova boot, for example:
$ nova boot --image IMAGE_ID --flavor 1 --hint user-data FILE_LOC server-1
Utilizing NUMA in Cisco NFV Infrastructure
Non-uniform memory access (NUMA) is a method of configuring microprocessor clusters in a multiprocessing system so that they can share memory locally, improving performance, and future system expansion. NUMA is used in symmetric multiprocessing (SMP) systems.
Cisco VIM supports the nova scheduler ability to choose the hypervisor to spawn VMs based on NUMA topologies. If the instances do not have NUMA topologies specified, the filter places no constraints on the compute hosts selection. NUMA allows applications, such as NFV applications, to benefit from CPU pinning and huge pages supported for better performance.
To utilize NUMA, you must define and maintain a list of compute hosts to serve as the NFV hosts. You can configure this list in the setup_data.yaml NFV_HOSTS field. After Cisco VIM is deployed, you must create the host aggregation and NFV flavors that contain the compute hosts where the NFV instances will be scheduled.
By default, CPU has two cores to run host-level general purpose tasks; no additional cores are isolated for host level tasks. The huge page size of Cisco VIM is two MB.
1 While most of the NUMA configurations are enabled on day-0, you can roll-in the disable hyperthreading feature on a newly added compute node. To disable the hyper-threading on a new compute node, update the setup_data.yaml file with the following option and then initiate the addition of the compute nodes:
DISABLE_HYPERTHREADING: True or False; this is optional and default value is false.
Note You can not revert the disable hyperthreading feature as the disable-hyperthreading is a non-reversible option in the setup_data.yaml file.
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
9
Managing Cisco NFVI
Monitoring Cisco NFVI Health with CloudPulse
2 To disable hyper-threading, on existing computes on day-n, the administrator should remove the existing compute nodes and add new computes.
Note We recommend you to not run a pod in an hybrid-mode; that is, a sub-set of compute nodes have hyper-threading disabled in them. The administrator has to remove the existing compute nodes and add them as new compute nodes, so that the hyper-threading feature is disabled in all the compute nodes in a pod.
Monitoring Cisco NFVI Health with CloudPulse
You can query the state of various Cisco NFVI OpenStack end points using CloudPulse, an OpenStack health-checking tool. By default, the tool automatically polls OpenStack Cinder, Glance, Nova, Neutron,
Keystone, Rabbit, Mariadb, and Ceph every four minutes. However, you can use a CLI REST API call from the management node to get the status of these services in real time. Also you can integrate the CloudPulse
API into your applications and get the health of the OpenStack services on demand. You can find additional information about using CloudPulse in the following OpenStack sites:
• https://wiki.openstack.org/wiki/Cloudpulse
• https://wiki.openstack.org/wiki/Cloudpulseclient
• https://wiki.openstack.org/wiki/Cloudpulse/DeveloperNotes
• https://wiki.openstack.org/wiki/Cloudpulse/OperatorTests
• https://wiki.openstack.org/wiki/Cloudpulse/APIDocs
CloudPulse has two set of tests: endpoint_scenario (runs as a cron or manually) and operator test (run manually).
The supported Cloudpulse tests groups include:
• nova_endpoint
• neutron_endpoint
• keystone_endpoint
• glance_endpoint
• cinder_endpoint
Operator tests include:
• ceph_check — Executes the command, "ceph -f json status" on the Ceph-mon nodes and parses the output.
If the result of the output is not “ HEALTH_OK ” ceph_check will report an error.
• docker_check — Finds out if all the Docker containers are in the running state in all the nodes. It will report an error if any containers are in the Exited state. It runs the command “ docker ps -aq --filter
'status=exited' ” .
• galera_check — Executes the command, "mysql 'SHOW STATUS; ” on the controller nodes and displays the status.
• node_check — Checks if all the nodes in the system are up and online. It also compares the result of
“ nova hypervisor list ” and finds out if all the computes are available.
10
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
Managing Cisco NFVI
Monitoring Cisco NFVI Health with CloudPulse
• rabbitmq_check — Runs the command, “ rabbitmqctl cluster_status ” on the controller nodes and finds out if the rabbitmq cluster is in quorum. If nodes are offline in the cluster rabbitmq_check will report as failed.
CloudPulse servers are installed in containers on all control nodes. The CloudPulse client is installed on the management node by the Cisco VIM installer. To execute CloudPulse, source the openrc file in the openstack-configs directory and execute the following:
[root@MercRegTB1 openstack-configs]# cloudpulse --help usage: cloudpulse [--version] [--debug] [--os-cache]
[--os-region-name <region-name>]
[--os-tenant-id <auth-tenant-id>]
[--service-type <service-type>]
[--endpoint-type <endpoint-type>]
[--cloudpulse-api-version <cloudpulse-api-ver>]
[--os-cacert <ca-certificate>] [--insecure]
[--bypass-url <bypass-url>] [--os-auth-system <auth-system>]
[--os-username <username>] [--os-password <password>]
[--os-tenant-name <tenant-name>] [--os-token <token>]
[--os-auth-url <auth-url>]
<subcommand> ...
To check results of periodic CloudPulse runs:
# cd /root/openstack-configs
# source openrc
# cloudpulse result
+--------------------------------------+------+-------------------+----------+---------+
| uuid | id | name | testtype | state |
+--------------------------------------+------+-------------------+----------+---------+
| bf7fac70-7e46-4577-b339-b1535b6237e8 | 3788 | glance_endpoint | periodic | success |
| 1f575ad6-0679-4e5d-bc15-952bade09f19 | 3791 | nova_endpoint | periodic | success |
| 765083d0-e000-4146-8235-ca106fa89864 | 3794 | neutron_endpoint | periodic | success |
| c1c8e3ea-29bf-4fa8-91dd-c13a31042114 | 3797 | cinder_endpoint | periodic | success |
| 04b0cb48-16a3-40d3-aa18-582b8d25e105 | 3800 | keystone_endpoint | periodic | success |
| db42185f-12d9-47ff-b2f9-4337744bf7e5 | 3803 | glance_endpoint | periodic | success |
| 90aa9e7c-99ea-4410-8516-1c08beb4144e | 3806 | nova_endpoint | periodic | success |
| d393a959-c727-4b5e-9893-e229efb88893 | 3809 | neutron_endpoint | periodic | success |
| 50c31b57-d4e6-4cf1-a461-8228fa7a9be1 | 3812 | cinder_endpoint | periodic | success |
| d1245146-2683-40da-b0e6-dbf56e5f4379 | 3815 | keystone_endpoint | periodic | success |
| ce8b9165-5f26-4610-963c-3ff12062a10a | 3818 | glance_endpoint | periodic | success |
| 6a727168-8d47-4a1d-8aa0-65b942898214 | 3821 | nova_endpoint | periodic | success |
| 6fbf48ad-d97f-4a41-be39-e04668a328fd | 3824 | neutron_endpoint | periodic | success |
+--------------------------------------+------+-------------------+----------+---------+
To view all CloudPulse tests:
# cd /root/openstack-configs
# source openrc
# cloudpulse test-list
To run a CloudPulse test on demand:
# cd /root/openstack-configs
# source openrc
# cloudpulse run --name <test_name>
# cloudpulse run --all-tests
# cloudpulse run --all-endpoint-tests
# cloudpulse run --all-operator-tests
To run a specific CloudPulse test on demand:
# cloudpulse run – -name neutron_endpoint
+------------+--------------------------------------+
| Property | Value |
+------------+--------------------------------------+
| name | neutron_endpoint |
| created_at | 2016-03-29T02:20:16.840581+00:00 |
| updated_at | None
| state | scheduled
| result | NotYetRun
|
|
|
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
11
Managing Cisco NFVI
Assessing Cisco NFVI status with cloud-sanity
| testtype | manual
| id | 3827
|
|
| uuid | 5cc39fa8-826c-4a91-9514-6c6de050e503 |
+------------+--------------------------------------+
To show detailed results of a specific CloudPulse run:
#cloudpulse show 5cc39fa8-826c-4a91-9514-6c6de050e503
+------------+--------------------------------------+
| Property | Value |
+------------+--------------------------------------+
| name | neutron_endpoint
| created_at | 2016-03-29T02:20:16+00:00
| updated_at | 2016-03-29T02:20:41+00:00
| state | success
| result | success
| testtype | manual
| id | 3827
|
|
| uuid | 5cc39fa8-826c-4a91-9514-6c6de050e503 |
+------------+--------------------------------------+
|
|
|
|
|
To see the CloudPulse options, source the openrc file in openstack-configs dir and execute:
#cloudpulse --help
The cloudpulse project has a RESTful Http service called the Openstack Health API. Through this API cloudpulse allows the user to list the cloudpulse tests, create new cloudpulse tests and see the results of the cloudpulse results.
All API calls described in this documentation require keystone authentication. We can use the keystone v2 or v3 version for the authentication. The corresponding configuration should be configured properly in the cloudpulse config in order that the cloudpulse can reach the v2 or the v3 keystone API
The Identity service generates authentication tokens that permit access to the Cloudpulse REST APIs. Clients obtain this token and the URL endpoints for other service APIs by supplying their valid credentials to the authentication service. Each time you make a REST API request to Cloudpulse, you supply your authentication token in the X-Auth-Token request header.
Assessing Cisco NFVI status with cloud-sanity
The cloud-sanity tool is designed to give you a quick overall status of the Pods health. Cloud-sanity can run tests on all node types in the Pod: management, control, compute and ceph storage.
The following are test areas supported in cloud-sanity:
1 RAID Disk health checks.
2 Basic network connectivity between the management node and all other nodes in the Pod.
3 Mariadb cluster size.
4 RabbitMQ operation and status.
5 Nova service and hypervisor list.
6 CEPHMon operation and status.
7 CEPHOSD operation and status.
To run the cloud-sanity tool, login to the management node and navigate to the tools directory for the installation currently running. Below are the cloud-sanity run options, cloud-sanity can be run on all nodes or a particular target role.
12
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
Managing Cisco NFVI
Assessing Cisco NFVI status with cloud-sanity
Procedure
Step 1 To run the cloud sanity complete the following steps:
# cd /root/installer-<tag>/tools
# ./cloud_sanity.py
– h usage: cloud_sanity.py [-h] [--check CHECK] [--list] [--verbose] cloud sanity helper optional arguments:
-h, --help show this help message and exit
--check CHECK, -c CHECK all - Run all sanity checks. [default action] control - Run controller sanity checks.
--list, -l
--verbose, -v compute - Run compute sanity checks.
cephmon - Run cephmon sanity checks.
cephosd - Run cephosd sanity checks.
management - Run Management node sanity checks
List all the available sanity checks.
Run the sanity in verbose mode.
Step 2 To run all the cloud-sanity tests select "all" as the check option.
./cloud_sanity.py --check all
| Control
|
| Control
|
| Control
|
| Control
|
| Control
|
| Compute
|
| Compute
|
| Compute
Executing All Cloud Sanity in quiet mode. This will take some time.
Cloud Sanity Results
+-------------+------------------------------------------------------------+---------+
| Role | Task | Result |
+-------------+------------------------------------------------------------+---------+
| Management | Management - Disk maintenance RAID Health **************** | PASSED |
| | | |
| Management | Management - Disk maintenance VD Health ****************** | PASSED |
| | | |
| Control
|
| Control - Ping All Controller Nodes ********************** | PASSED |
| | |
| Control
|
| Control
|
| Control - Ping internal VIP ****************************** | PASSED
| |
|
|
| Control - Check Mariadb cluster size ********************* | PASSED |
| | |
| Control - Check RabbitMQ is running ********************** | PASSED |
|
|
|
|
|
|
|
|
|
| Control - Disk maintenance VD Health ********************* | PASSED
|
|
| Control - Check RabbitMQ cluster status ****************** | PASSED |
|
| Control - Check Nova service list ************************ | PASSED |
|
| Control - Disk maintenance RAID Health ******************* | PASSED |
|
|
|
| Compute - Ping All Compute Nodes ************************* | PASSED |
| | |
| Compute - Check Nova Hypervisor list ********************* | PASSED |
| | |
| Compute - Disk maintenance RAID Health ******************* | PASSED |
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
13
Managing Cisco NFVI
Service Catalog URL
|
| Compute
|
| CephMon
|
| CephMon
|
| CephMon
|
| CephMon
| | |
| Compute - Disk maintenance VD Health ********************* | PASSED |
| | |
| CephMon - Check cephmon is running *********************** | PASSED |
| | |
| CephMon - CEPH cluster check ***************************** | PASSED |
| | |
| CephMon - Check Ceph Mon status ************************** | PASSED |
| | |
| CephMon - Check Ceph Mon results ************************* | PASSED |
|
| CephOSD
|
| CephOSD
| | |
| CephOSD - Ping All Storage Nodes ************************* | PASSED |
| | |
| CephOSD - Check OSD result with osdinfo ****************** | PASSED |
|
| CephOSD
| | |
| CephOSD - Check OSD result without osdinfo *************** | PASSED |
| | | |
+-------------+------------------------------------------------------------+---------+
[PASSED] Cloud Sanity All Checks Passed
The cloud-sanity tests use the disk-maintenance and osd-maintenance tools to assess overall health and status of RAID disks and OSD status.
Note Failures detected in RAID disk health and CEPHOSD operational status can be future evaluated with the disk-maintenance and osd-maintenance tools. See the sections on those tools for information on their use.
Service Catalog URL
The OpenStack Keystone service catalog allows API clients to dynamically discover and navigate to cloud services. Cloudpulse has its own service URL which is added to the keystone service catalog. Send a token request to Keystone to find the service URL of cloudpulse . The token request will list all the catalog of services available.
Get Token from Keystone
To get the token from keystone we have to use the following request:
Resource URI
Verb
POST
URI http://<controller_lb_ip>:5000/v2.0/tokens
Example
JSON Request
POST / v2.0/tokens
Accept: application/json
14
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
Managing Cisco NFVI
Get Service Catalog URL for Cloudpulse
{
"auth": {
"passwordCredentials":{
"username": "admin",
"password": "iVP1YciVKoMGId1O"
}
}
}
JSON Response
200 OK
Content-Type: application/json
{
"access": {
"token": {
"issued_at": "2017-03-29T09:54:01.000000Z",
"expires": "2017-03-29T10:54:01Z",
"id":
"gAAAAABY24Q5TDIqizuGmhOXakV2rIzSvSPQpMAmC7SA2UzUXZQXSH-ME98d3Fp4Fsj16G561a420B4BK0fylcykL22EcO9",
…………
…… ..
}
Get Service Catalog URL for Cloudpulse
Resource URI
Verb
GET
URI http://<controller_ip>:35357/v2.0/endpoints
Example
JSON Request
GET /v2.0/endpoints
Accept: application/json
JSON Response
200 OK
Content-Type: application/json
{"endpoints": [
{"internalurl": "http://<controller>:9999",
"adminurl": "http://<controller>:9999",
"publicurl":"http://<controller>:9999"
}]}
}
Cloudpulse API's
The following are a list of API's and the corresponding functions that the API performs. The cloudpulse API's should always be accessed with the X-Auth-Token which contains the token which is received from the keystone token generation API mentioned i the preceding section.
List of Cloudpulse Tests
To get the list of cloudpulse tests:
Resource URI
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
15
Managing Cisco NFVI
Get detailed result of 1 test
Verb
GET
URI http://<controller_ip>:9999/cpulse
Example
JSON Request
GET /cpulse
Accept: application/json
JSON Response
200 OK
Content-Type: application/json
{
"cpulses": [
{
"name": "galera_check",
"state": "success",
"result":"ActiveNodes:16.0.0.37,16.0.0.17,16.0.0.27",
"testtype": "periodic",
"id": 4122,
"uuid": "a1b52d0a-ca72-448a-8cc0-5bf210438d89"
}]
}
Get detailed result of 1 test
To get detailed result of the test.
Resource URI
Verb
GET
URI http://<controller_ip>:9999/cpulse/<uuid>
Uuid : uuid of the test
Example
JSON Request
GET /cpulse/e6d4de91-8311-4343-973b-c507d8806e94
Accept: application/json
JSON Response
200 OK
Content-Type: application/json
{
"name": "galera_check",
"state": "success",
"result":"ActiveNodes:16.0.0.37,16.0.0.17,16.0.0.27",
"testtype": "periodic",
"id": 4122,
"uuid": " e6d4de91-8311-4343-973b-c507d8806e94"
}
16
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
Managing Cisco NFVI
Get List of Tests Available
Get List of Tests Available
To get a list of available cloudpulse tests:
Resource URI
Verb
GET
URI http://<controller_ip>:9999/cpulse/list_tests
Example
JSON Request
GET /cpulse/list_tests
Accept: application/json
JSON Response
200 OK
Content-Type: application/json
{
"endpoint_scenario":
"all_endpoint_tests\ncinder_endpoint\nglance_endpoint\nkeystone_endpoint\nneutron_endpoint\nnova_endpoint",
"operator_scenario":
"all_operator_tests\nceph_check\ndocker_check\ngalera_check\nnode_check\nrabbitmq_check"
}
Schedule a manual cloudpulse test:
To schedule a manual test of cloudpulse
Resource URI
Verb
POST
URI http://<controller_ip>:9999/cpulse
Example
JSON Request
POST /cpulse
Accept: application/json
{
"name": "galera_check"
}
JSON Response
200 OK
Content-Type: application/json
{
"name": "galera_check",
"state": "scheduled",
"result":"NotYetRun",
"testtype": "manual",
"id": 4122,
"uuid": " e6d4de91-8311-4343-973b-c507d8806e94"
}
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
17
Managing Cisco NFVI
Remove the results of a test
•
Remove the results of a test
To remove the results of a test.
Resource URI
Verb
DELETE
URI http://<controller_ip>:9999/cpulse/<uuid>
Uuid : uuid of the test
Example
JSON Request
DELETE /cpulse/68ffaae3-9274-46fd-b52f-ba2d039c8654
Accept: application/json
JSON Response
204 No Content
Checking Network Connections
You can use Virtual Machine Through Put (VMTP) to check Layer 2 and Layer 3 data plane traffic between
Cisco NFVI compute nodes. VMTP performs ping connectivity, round trip time measurement (latency), and
TCP/UDP throughput measurement for the following Cisco NFVI east to west VM-to-VM flows:
• Same network (private fixed IP, flow number 1).
• Different network using fixed IP (same as intra-tenant L3 fixed IP, flow number 2).
• Different network using floating IP and NAT (same as floating IP inter-tenant L3, flow number 3.)
• When an external Linux host is available for testing north to south flows, external host to VM download and upload throughput and latency (L3/floating IP, flow numbers 4 and 5).
18
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
Managing Cisco NFVI
Enabling NFVBench Post Deployment
The following figure shows the traffic flows VMTP measures. Cloud traffic flows are checked during Cisco
VIM installation and can be checked at any later time by entering the following command:
$ ciscovim run --perform 8 – y
Figure 1: VMTP Cloud Traffic Monitoring
Enabling NFVBench Post Deployment
NFVBench is a data plane performance benchmark tool for NFVI that can be optionally installed after the pod deployment.
NFVBench is used to:
• Verify that the data plane is working properly and efficiently when using well defined packet paths that are typical of NFV service chains.
• Measure the actual performance of your data plane so that you can estimate what VNFs can expect from the infrastructure when it comes to receiving and sending packets.
While VMTP only measures VM to VM traffic, NFVBench measures traffic flowing from an integrated software traffic generator (TRex) running on the management node to the ToR switches to test VMs running in compute nodes.
In Cisco VIM, the NFVBench (performance benchmark) is an optional tool. You can deploy NFVBench after the installation of the pod.
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
19
Managing Cisco NFVI
Enabling NFVBench Post Deployment
Before You Begin
• A 10GE Intel NIC (Intel X710 NIC (4 x 10G)) must be installed on a management node.
• A TRex traffic generator which uses DPDK interface to interact with Intel NIC and makes use of hardware, instead of software to generate packets. This approach is more scalable and enables NFVBench to perform tests without software limitations.
• Wire two physical interfaces of the Intel NIC to the TOR switches (as shown in the following figure).
Figure 2: NFVBench topology setup
Procedure
Command or Action Purpose
Step 1 Enable the NFVBench configuration in the setup_data.yaml file.
Sample configuration files for OVS/VLAN or VPP mechanism driver:
NFVBENCH: enabled: True # True or False tor_info: {TORa: eth1/42, TORb: eth1/42} # mandatory
# tor_info: {TOR: 'eth1/42,eth1/43'} # use if there is only one
TOR switch
# nic_ports: 3,4
4 available ports
# Optional input, indicates which 2 of the
# of 10G Intel NIC on the management node is
NFVbench tool using
# to send and receive traffic.
# Defaults to the first 2 ports of NIC (ports
1 and 2) if not specified.
# Port number must be between 1 and 4, one port cannot be used twice.
# Example:
# nic_ports: 1,4 port of Intel NIC are used
# the first and the last
20
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
Managing Cisco NFVI
Enabling NFVBench Post Deployment
Command or Action Purpose
Sample configuration for VTS mechanism driver:
NFVBENCH: enabled: True # True or False tor_info: {TORa: eth1/42, TORb: eth1/42} # mandatory vtep_vlans: 1500,1501
VTS/VXLAN.
# Mandatory and needed only for
# Specify any pair of unused VLAN ids to be used
# for VLAN to VxLAN encapsulation in
# tor_info: {TOR: 'eth1/42,eth1/43'} # Use if there is only one
TOR switch.
#
TOR switch.
nic_ports: 3,4
4 available ports
# Optional input, indicates which 2 of the
# of 10G Intel NIC on the management node is
NFVbench tool using
# to send and receive traffic.
# Defaults to the first 2 ports of NIC (ports
1 and 2) if not specified.
# Port number must be between 1 and 4, one port cannot be used twice.
# Example:
# nic_ports: 1,4 port of Intel NIC are used
# the first and the last
VTS_PARAMETERS:
…
VTS_DAY0: '<True|False> ’ # Required parameter when VTS enabled
VTS_USERNAME: '<vts_username>'# Required parameter when VTS enabled
VTS_PASSWORD: '<vts_password>'# Required parameter when VTS enabled
VTS_NCS_IP: '11.11.11.111'# '<vts_ncs_ip>', mandatory when VTS enabled
VTC_SSH_USERNAME: 'admin'# '<vtc_ssh_username>', mandatory for
NFVbench
VTC_SSH_PASSWORD: 'my_password'# '<vtc_ssh_password>', mandatory for NFVbench
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
21
Managing Cisco NFVI
NFVBench Usage
Command or Action Purpose
Step 2 Configuring minimal settings of
NFVBench:
# Minimal settings required for NFVbench
TORSWITCHINFO:
CONFIGURE_TORS: <True or False> # True if switches should be configured to support NFVbench
…
SWITCHDETAILS:
- hostname: 'TORa' # Hostname matching 'tor_info' switch name.
username: 'admin' # Login username for switch user.
password: 'my_password' # Login password for switch user.
ssh_ip: '172.31.230.123' # SSH IP for switch.
- hostname: 'TORb' username: 'admin' password: 'my_password' ssh_ip: '172.31.230.124'
TOR switches will be configured based on information provided in tor_info.
Two ports specified by interfaces are configured in trunk mode. In order to access them and retrieve TX/RX counters you need the Login details for TOR switches. It is not required to set 'CONFIGURE_TORS' to 'True', but then manual configuration is necessary.
With VTS as mechanism driver additional settings are needed. NFVBench needs access to VTS NCS to perform cleanup after it detaches the traffic generator port from VTS. Also a pair of VTEP VLANs is required for VLAN to VxLAN mapping. Value can be any pair of unused VLAN ID.
Step 3 Reconfigure Cisco
VIM to create a
NFVBench container.
To reconfigure add necessary configuration to the setup_data.yaml file, run the reconfigure command as follows.
[root@mgmt1 ~]# cd /root/
[root@mgmt1 ~]# mkdir MyDir
[root@mgmt1 ~]# cp /root/openstack-configs/setup_data.yaml
/root/MyDir/
[root@mgmt1 ~]# cd /root/
[root@mgmt1 ~]# # update the setup_data to include NFVBENCH section
[root@mgmt1 ~]# cd /root/MyDir/
[root@mgmt1 ~]# vi setup_data.yaml
[root@mgmt1 ~]# cd ~/installer-xxxx
[root@mgmt1 ~]# ciscovim --setupfile /root/MyDir/setup_data.yaml
reconfigure
After reconfiguration is done, you can see NFVBench container up and is ready to use.
NFVBench Usage
Built-in packet paths
NFVBench can setup and stage three different packet paths.
22
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
Managing Cisco NFVI
NFVBench Usage
The default packet path is called PVP (Physical - VM - Physical) and represents a typical service chain made of 1 VNF/VM:
Figure 3: Single VNF chain (PVP)
The traffic generator runs inside the NFVBench container on the management node. DC-SW represents the top of rack switch(es). The VNF is a test VM that contains a fast L3 router based on FD.io VPP. This VNF image can also be configured to run an L2 forwarder based on DPDK testpmd (both options generally yield roughly similar throughput results).
Traffic is made of UDP packets generated on the 2 physical interfaces (making it a bi-directional traffic).
Packets are forwarded by the switch to the appropriate compute node before arriving to the virtual switch, then to the VNF before looping back to the traffic generator on the other interface. Proper stitching of the traffic on the switch is performed by NFVbench by using the appropriate mechanism (VLAN tagging for
VLAN based deployments, VxLAN VTEP in the case of VTS deployments).
The performance of the PVP packet path provides a very good indication of the capabilities and efficiency of the NFVi data plane in the case of a single service chain made of 1 VNF/VM.
NFVBench also supports more complex service chains made of 2 VM in sequence and called PVVP
(Physical-VM-VM-Physical).
In a PVVP packet path, the 2 VMs can reside on the same compute node (PVVP intra-node) or on different compute nodes (PVVP inter-node).
PVVP intra-node is more efficient when a virtual switch is used as packets do not have to go through the switch between the 2 VMs:
Figure 4: 2-VNF chain (PVVP)
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
23
Managing Cisco NFVI
NFVBench Command Line Options
PVVP inter-node requires packets to go through the switch and back between the 2 VMs.
Figure 5: 2-VNF chain(inter-node PVVP)
NFVBench Command Line Options
The common NFVBench command line options can be displayed using the --help option:
[root@mgmt1 ~]# nfvbench --help
Control Plane Verification
If you are trying NFVBench for the first time, verify that the tool can stage the default packet path properly without sending any traffic.
The --no-traffic option will exercise the control plane by creating a single test service chain with one VM but does not send any traffic.
The following command will only stage the default PVP packet path (but will not generate any traffic):
[root@mgmt1 ~]# nfvbench --no-traffic
Fixed Rate Run Test
The data plane traffic test is to generate traffic at a fixed rate for a fixed duration. For example, to generate a total of 10,000 packets per second (which is 5,000 packets per second per direction) for the default duration
(60 seconds) and using the default frame size of 64 bytes::
[root@mgmt1 ~]# nfvbench --help
24
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
Managing Cisco NFVI
Fixed Rate Run Test
Packet Sizes
You can specify any list of frame sizes using the -frame-size option (pass as many as desired), including IMIX.
Following is an example, to run a fixed rate with IMIX and 1518 byte frames:
[root@mgmt1 ~]# nfvbench --rate 10kpps – frame-size IMIX – frame-size 1518
NDR and PDR Test
NDR and PDR test is used to determine the performance of the data plane in terms of throughput at given drop rate.
• No Drop Rate(NDR)-- It is the highest throughput achieved while allowing zero packet drop. (allows a very low drop rate usually lesser than 0.001%).
• Partial Drop Rate (PDR)--It is the highest throughput achieved while allowing most at a given drop rate
(typically less than 0.1%).
NDR is always less or equal to PDR.
To calculate the NDR and PDR for your pod run the following command:
[root@mgmt1 ~]# nfvbench --rate ndr_pdr
Multi-chain Test
In multi-chain test, each chain represents an independent packet path symbolizing real VNF chain. You can run multiple concurrent chains and better simulate network conditions in real production environment. Results with single chain versus with multiple chains usually vary because of services competing for resources (RAM,
CPU, and network).
To stage and measure multiple service chains at the same time, use --service-chain-count flag or shorter -scc version.
The following example shows how to run the fixed rate run test with ten PVP chains:
[root@mgmt1 ~]# nfvbench -scc 10 --rate 100kpps
The following example shows how to run the NDR/PDR test with ten PVP chains:
[root@mgmt1 ~]# nfvbench -scc 10 --rate ndr_pdr
Multi-flow Test
One flow is defined by a source and destination MAC/IP/port tuple in the generated packets. It is possible to have many flows per chain. The maximum number of flows supported is in the order of 1 million flows per direction.
The following command will run three chains with a total of 100K flows per direction (for all chains):
[root@mgmt1 ~]# nfvbench -scc 3 -fc 100k
External Chain Test
NFVBench measures the performance of chains that are pre-staged (using any means external to NFVBench).
Such chains can be real VNFs with L3 routing capabilities or L2 forwarding chains.
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
25
Managing Cisco NFVI
Fixed Rate Run Test
This test is used when user wants to use NFVBench for only traffic generation. In this case, NFVBench sends traffic from traffic generator and reports results without performing any configuration.
You must do necessary configurations such as creating networks and VMs with configuration that allows generated traffic to pass. NFVBench needs to know the 2 edge networks to which the traffic generator will be attached.
If the external chains only support L2 forwarding, the NFVBench configuration must:
• Enable VLAN tagging and define the VLAN IDs to use - if applicable (or disable vlan tagging if it is not needed).
• The destination MAC to use in each direction (this will depend on the L2 forwarding mode in place in the service chain).
If the external chains support IPv4 routing, the NFVBench configuration must:
• Define the public IP addresses of the service chain end points (gateway IP) that will be used to discover destination MAC using ARP.
• Set the vlan tagging appropriately.
To measure performance for external chains, use the --service-chain EXT (or -sc EXT ) option:
[root@mgmt1 ~]# nfvbench -sc EXT
Note NFVBench will not access ToR switches or v-switch in compute node.
NFVBench Result Generation and Storage
NFVBench detailed results can be stored in JSON format if passed the --json option with a destination file name or the --std-json option with a destination folder pathname (if you want to use a standard file name generated by NFVBench). It is also possible to use both methods to generate the output in to two different files at the same time:
[root@mgmt1 ~]# nfvbench -scc 3 -fc 10 -fs 64 --json /tmp/nfvbench/my.json --std-json
/tmp/nfvbench
The above command will create two JSON files in /tmp/nfvbench container directory, which is mapped to the host directory. The first file will be named my.json.
With the--std-jsonoption, the standard NFVBench filename format follows this pattern:
<service-chain-type>-<service-chain-count>-<flow-count>-<frame-sizes>.json
Default chain is PVP and flag -fs was used to override traffic profile in configuration file. With 3 chains and
10 flows specified, file PVP-3-10-64.json
was created
Interpretation of Results
NFVBench prints data to command line in a table form. The data includes the current configuration, test devices details, and results computed based on traffic statistics.
Fixed Rate
26
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
Managing Cisco NFVI
Fixed Rate Run Test
Run the following command on NFVBench to view the traffic generated at fixed rate at different components of the packet path:
[root@mgmt1 ~]# nfvbench --rate 5kpps -fs IMIX
NFVBench summary consists of multiple blocks. In some cases, NFVBench displays lesser data. For example, in the output, the EXT chain does not access some path components (like switch). Therefore, the summary does not display
========== NFVBench Summary ==========
Date: 2017-03-28 19:59:53
NFVBench version 0.3.5
Openstack Neutron: vSwitch: VTS
Encapsulation: VxLAN
Benchmarks:
> Networks:
> Components:
> TOR:
Type: N9K
Version:
10.28.108.249:
BIOS: 07.34
NXOS: 7.0(3)I2(2b)
10.28.108.248:
BIOS: 07.34
NXOS: 7.0(3)I2(2b)
> VTC:
Version: build_date: 2017-03-03-05-41 build_number: 14 git_revision: 0983910 vts_version: 2.3.0.40
git_branch: vts231newton job_name: vts231newton_gerrit_nightly
> Traffic Generator:
Profile: trex-local
Tool: TRex ≠
Version: build_date: Feb 16 2017 version: v2.18
built_by: hhaim build_time: 18:59:02
> Service chain:
> PVP:
> Traffic:
VPP version: sjc04-pod3-compute-4: v17.04-rc0~98-g8bf68e8
Profile: custom_traffic_profile
Bidirectional: True
Flow count: 1
Service chains count: 1
Compute nodes: [u'nova:sjc04-pod3-compute-4']
Run Summary:
+-----------------+-------------+----------------------+----------------------+----------------------+
| L2 Frame Size | Drop Rate | Avg Latency (usec) | Min Latency (usec)
| Max Latency (usec) |
+=================+=============+======================+======================+======================+
|
| IMIX
241.00 |
| 0.0000% | 16.50 | 10.00
+-----------------+-------------+----------------------+----------------------+----------------------+
L2 frame size: IMIX
Chain analysis duration: 73 seconds
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
27
Managing Cisco NFVI
Fixed Rate Run Test
Run Config:
+-------------+------------------+--------------+-----------+
| Direction | Duration (sec) | Rate | Rate |
+=============+==================+==============+===========+
| Forward | 60 | 7.6367 Mbps | 2,500 pps |
+-------------+------------------+--------------+-----------+
| Reverse | 60 | 7.6367 Mbps | 2,500 pps |
+-------------+------------------+--------------+-----------+
| Total | 60 | 15.2733 Mbps | 5,000 pps |
+-------------+------------------+--------------+-----------+
Chain Analysis:
+----------------------+----------+-----------------+---------------+---------------+-----------------+---------------+---------------+
| Interface | Device | Packets (fwd) | Drops (fwd) | Drop%
(fwd) | Packets (rev) | Drops (rev) | Drop% (rev) |
+======================+==========+=================+===============+===============+=================+===============+===============+
|
| traffic-generator | trex |
150,042 | 0 | 0.0000%
150,042
|
| |
+----------------------+----------+-----------------+---------------+---------------+-----------------+---------------+---------------+
0.0000% |
| vni-5098
150,042 |
|
0 n9k
|
| 150,042
0.0000% |
| 0 |
+----------------------+----------+-----------------+---------------+---------------+-----------------+---------------+---------------+
0.0000% |
| vxlan_tunnel0
150,042 |
|
0 vpp
|
| 150,042
0.0000% |
| 0 |
+----------------------+----------+-----------------+---------------+---------------+-----------------+---------------+---------------+
| 0 |
0.0000% |
| VirtualEthernet0/0/1 | vpp
150,042 | 0 |
| 150,042
0.0000% |
+----------------------+----------+-----------------+---------------+---------------+-----------------+---------------+---------------+
0.0000% |
| VirtualEthernet0/0/0 | vpp
150,042 | 0 |
| 150,042
0.0000% |
| 0 |
+----------------------+----------+-----------------+---------------+---------------+-----------------+---------------+---------------+
0.0000% |
| vxlan_tunnel1
150,042 |
| vpp
0 |
| 150,042
0.0000% |
| 0 |
+----------------------+----------+-----------------+---------------+---------------+-----------------+---------------+---------------+
0.0000% |
| vni-5099
150,042 |
|
0 n9k
|
| 150,042
0.0000% |
| 0 |
+----------------------+----------+-----------------+---------------+---------------+-----------------+---------------+---------------+
0.0000% |
| traffic-generator | trex |
150,042 | |
150,042
|
| 0 |
+----------------------+----------+-----------------+---------------+---------------+-----------------+---------------+---------------+
Run as: nfvbench -c /tmp/nfvbench/nfvbench.cfg --rate 5kpps -fs IMIX
Summary Interpretation:
Lines 1-34: General information about host system and used components.
Lines 35-45: Test-specific information about service chain, traffic profile, and compute nodes.
28
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
Managing Cisco NFVI
Fixed Rate Run Test
Lines 46-53: Summary of traffic profile run with results. A new row is added in the table for every packet size in test. The output displays the run summary for the IMIX packet size, but lines for 64B and 1518B can also be present as well. Table contains following columns:
The run summary table includes the following columns:
• Drop Rate: The percentage of total drop rate for all chains and flows from the total traffic sent.
• Avg Latency: Average latency of average chain latencies in microseconds.
• Min Latency: Minimum latency of all chain latencies in microseconds.
• Max Latency: Maximum latency of all chain latencies in microseconds.
Lines 54-68: Length of test in seconds for given packet size and table displaying rate and duration which was used for running traffic in the test.
Lines 69-89: Detailed analysis of test. Each row represents one interface on packet path in order they are visited. Left side of the table is for forward direction (from traffic generator port 0 to port 1), right side is for reverse direction (from traffic generator port 1 to port 0).
The chain analysis table has following columns:
• Interface: Interface name on devices in packet path.
• Device: Device name on which the interface is displayed in the first column is available.
• Packets (fwd): RX counter on given interface, only the first row is TX counter (it is the beginning of packet path).
• Drops (fwd): Amount of packets being dropped between current and previous interface.
• Drop% (fwd): Percentage of dropped packets on this interface to the total packet drops.
• Packets (rev): Similar as Packets (fwd) but for reverse direction.
• Drops (rev): Similar as Drops (fwd) but for reverse direction.
• Drop% (rev): Similar as Drop% (fwd) but for reverse direction.
This type of summary is very useful for finding bottlenecks or to verify if the system can handle certain fixed rate of traffic.
NDR/PDR
The test result shows throughput values in different units for both NDR and PDR with latency statistics
(minimum, maximum, average) for each test.
[root@mgmt1 ~]# nfvbench --rate ndr_pdr -fs IMIX
========== NFVBench Summary ==========
Date: 2017-03-28 20:20:46
NFVBench version 0.3.5
Openstack Neutron: vSwitch: VTS
Encapsulation: VxLAN
Benchmarks:
> Networks:
> Components:
> TOR:
Type: N9K
Version:
10.28.108.249:
BIOS: 07.34
NXOS: 7.0(3)I2(2b)
10.28.108.248:
BIOS: 07.34
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
29
Managing Cisco NFVI
Fixed Rate Run Test
NXOS: 7.0(3)I2(2b)
> VTC:
Version: build_date: 2017-03-03-05-41 build_number: 14 git_revision: 0983910 vts_version: 2.3.0.40
git_branch: vts231newton job_name: vts231newton_gerrit_nightly
> Traffic Generator:
Profile: trex-local
Tool: TRex
Version: build_date: Feb 16 2017 version: v2.18
built_by: hhaim build_time: 18:59:02
> Measurement Parameters:
NDR: 0.001
PDR: 0.1
> Service chain:
> PVP:
> Traffic:
VPP version: sjc04-pod3-compute-4: v17.04-rc0~98-g8bf68e8
Profile: custom_traffic_profile
Bidirectional: True
Flow count: 1
Service chains count: 1
Compute nodes: [u'nova:sjc04-pod3-compute-4']
Run Summary:
+-----+-----------------+------------------+------------------+-----------------+----------------------+----------------------+----------------------+
| | L2 Frame Size | Rate (fwd+rev) | Rate (fwd+rev) | Avg Drop
Rate | Avg Latency (usec) | Min Latency (usec) | Max Latency (usec) |
+=====+=================+==================+==================+=================+======================+======================+======================+
|
| NDR | IMIX
131.33 |
| 4.5703 Gbps
10.00 |
| 1,496,173 pps
404.00 |
| 0.0006%
+-----+-----------------+------------------+------------------+-----------------+----------------------+----------------------+----------------------+
|
| PDR | IMIX
205.72 |
| 4.7168 Gbps
20.00 |
| 1,544,128 pps
733.00 |
| 0.0553%
+-----+-----------------+------------------+------------------+-----------------+----------------------+----------------------+----------------------+
L2 frame size: IMIX
Chain analysis duration: 961 seconds
NDR search duration: 661 seconds
PDR search duration: 300 seconds
Run Config:
+-------------+------------------+-------------+---------------+
| Direction | Duration (sec) | Rate | Rate |
+=============+==================+=============+===============+
| Forward | 60 | 2.3584 Gbps | 772,064 pps |
+-------------+------------------+-------------+---------------+
| Reverse | 60 | 2.3584 Gbps | 772,064 pps |
+-------------+------------------+-------------+---------------+
| Total | 60 | 4.7168 Gbps | 1,544,128 pps |
+-------------+------------------+-------------+---------------+
Lines 1-48: Similar to the fixed rate run output explained above.
Lines 49-58: Summary of test run with benchmark data. For each packet size, there is a row with NDR/PDR or both values depending on chosen rate. The output displays the run summary for the IMIX packet size.
The table includes the following columns:
30
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
Managing Cisco NFVI
Fixed Rate Run Test
• L2 Frame Size: Packet size used in test, can be one of 64B, IMIX, 1518B
• Rate (fwd+rev): Total rate satisfying NDR/PDR condition in a unit bps/pps
• Avg Drop Rate: Average drop rate of test iteration which satisfied NDR/PDR condition
• Avg Latency: Average packet latency of test iteration which satisfied NDR/PDR condition in microseconds
• Min Latency: Minimum latency of test iteration which satisfied NDR/PDR condition in microseconds
• Max Latency: Maximum latency of test iteration which satisfied NDR/PDR condition in microseconds
The NDR and PDR values along with the latency information are good indicators of NFVI solution.
The following figure explains different approaches to interpret the same results.
Figure 6: Measured rates form the traffic generator
NFVBench always reports measured rate from the traffic generator perspective as total amount sent into the chain.
Advanced Configuration
More advanced use-cases require customization of the NFVbench configuration file. Steps below are optional.
The default NFVbench configuration file can be obtained by using the -show-default-config option.
For example, go to the host directory mapped to container (/root/nfvbench) and copy default NFVbench configuration file as follows:
[root@mgmt1 ~]# cd /root/nfvbench
[root@mgmt1 ~]# nfvbench – -show-default-config > nfvbench.cfg
You can then edit the nfvbench.cfg using any Linux text editor (read and follow nested comments to do custom configuration) and pass the new configuration file to NFVBench using the -c option.
Cisco VIM CLI
An alternative way to NFVBench CLI is to use ciscovimclient. Ciscovimclient is meant to provide an interface that is more consistent with the CiscoVIM CLI and can run remotely while the NFVBench CLI is executed on the management node.
Pass JSON configuration matching structure of the NFVBench config file to start a test:
[root@mgmt1 ~]# ciscovim nfvbench --config ‘ { “ rate ” : “ 10kpps ” }
+------------------+--------------------------------------+
| Name | Value |
+------------------+--------------------------------------+
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
31
Managing Cisco NFVI
Enabling or Disabling Autobackup of Management Node
| status | not_run
| nfvbench_request | {"rate": "5kpps"}
|
|
| uuid
| created_at
| 0f131259-d20f-420f-840d-363bdcc26eb9 |
| 2017-06-26T18:15:24.228637
|
+------------------+--------------------------------------+
Run the following command with the returned UUID to poll status:
[root@mgmt1 ~]# ciscovim nfvbench --stat 0f131259-d20f-420f-840d-363bdcc26eb9
+------------------+--------------------------------------+
| Name | Value |
+------------------+--------------------------------------+
| status | nfvbench_running
| nfvbench_request | {"rate": "5kpps"}
| uuid
| created_at
|
|
| 0f131259-d20f-420f-840d-363bdcc26eb9 |
| 2017-06-26T18:15:24.228637
|
| updated_at | 2017-06-26T18:15:32.385080
|
+------------------+--------------------------------------+
+------------------+--------------------------------------+
| Name | Value |
+------------------+--------------------------------------+
| status | nfvbench_completed |
| nfvbench_request | {"rate": "5kpps"} |
| uuid
| created_at
| 0f131259-d20f-420f-840d-363bdcc26eb9 |
| 2017-06-26T18:15:24.228637
|
| updated_at | 2017-06-26T18:18:32.045616
|
+------------------+--------------------------------------+
Once the test is done, retrieve results in a JSON format:
[root@mgmt1 ~]# ciscovim nfvbench --json 0f131259-d20f-420f-840d-363bdcc26eb9
{"status": "PROCESSED", "message": {"date": "2017-06-26 11:15:37", … }}
NFVBench REST Interface
When enabled, the NFVBench container can also take benchmark request from a local REST interface. Access is only local to the management node in the current Cisco VIM version (that is the REST client must run on the management node).
Details on the REST interface calls can be found in Chapter 2, Cisco VIM REST API Resources.
Enabling or Disabling Autobackup of Management Node
Cisco VIM 2.2 introduces the backup and recovery of the management node. By default, the feature is enabled.
Auto-snapshots of the management node happens during pod management operation. You can disable the autobackup of the management node.
To enable or disable the management node, update the setup_data.yaml file as follows:
# AutoBackup Configuration
# Default is True
#autobackup: <True or False>
Take a backup of setupdata file and update it manually with the configuration details by running the following command:
[root@mgmt1 ~]# cd /root/
[root@mgmt1 ~]# mkdir MyDir
[root@mgmt1 ~]# cp /root/openstack-configs/setup_data.yaml /root/MyDir/
[root@mgmt1 ~]# # update the setup_data to change autobackup
[root@mgmt1 ~]# cd /root/MyDir/
[root@mgmt1 ~]# vi setup_data.yaml
[root@mgmt1 ~]# cd ~/installer-xxxx
[root@mgmt1 ~]# ciscovim --setupfile /root/MyDir/setup_data.yaml reconfigure
32
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
Managing Cisco NFVI
Forwarding ELK logs to External Syslog Server
Forwarding ELK logs to External Syslog Server
Cisco VIM, supports backup and recovery of the management node. To keep the process predictable and to avoid loss of logs, the software supports the capability of forwarding the ELK logs to an external syslog server.
Capability has been introduced to enable this feature after the pod is up and running, with Cisco VIM, through the reconfigure option.
The Syslog Export reconfigure option supports the following options:
• Enable forwarding of ELK logs to External Syslog Server on a pod that is already up and running.
• Reconfigure existing External Syslog Setting to point to a different syslog cluster.
The following section needs to be configured in the setup_data.yaml file.
###################################
## SYSLOG EXPORT SETTINGS
###################################
SYSLOG_EXPORT_SETTINGS: remote_host: <syslog_ip_addr> # required, IP address of the remote syslog server protocol: udp # only udp is supported facility: local5 severity: debug port: 514
# <string; suggested value: debug>
# optional; destination port number, defaults to 514 clients: 'ELK' # optional; defaults and restricted to ELK in 2.x
# Please note other than the remote IP address host, most of the other info is not needed;
Also the client list in 2.2 is restricted to ELK only.
Take a backup of the setupdata file and update the file manually with the configs listed in the preceding section, then run the reconfigure command as follows:
[root@mgmt1 ~]# cd /root/
[root@mgmt1 ~]# mkdir MyDir
[root@mgmt1 ~]# cp /root/openstack-configs/setup_data.yaml /root/MyDir/
[root@mgmt1 ~]# # update the setup_data to include Syslog Export info
[root@mgmt1 ~]# cd /root/MyDir/
[root@mgmt1 ~]# vi setup_data.yaml
[root@mgmt1 ~]# cd ~/installer-xxxx
[root@mgmt1 ~]# ciscovim --setupfile /root/MyDir/setup_data.yaml reconfigure
With this configuration, you should now be able to use export ELK logs to an external syslog server. On the remote host, verify if the logs are forwarded from the management node.
Adding and Reconfiguring VIM Administrators
Cisco VIM supports management of VIM Administrators. A VIM administrator will have permissions to login to the management node through SSH or the console using the configured password. By configuring to one VIM admin account, administrators do not have to share credentials. Administrators will have individual accountability.
To enabled one or more VIM administrators, post VIM install follow the steps listed below.
Procedure
Step 1 Take a backup of the setupdata file and update the file manually with the configs listed as, vim_admins:
- vim_admin_username: <username> vim_admin_password_hash: <sha512-password-hash>
- vim_admin_username: <username>
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
33
Managing Cisco NFVI
Reconfigure of Proxy Post Install vim_admin_password_hash: <sha512-password-hash>
- vim_admin_username: <username> vim_admin_password_hash: <sha512-password-hash>
The value of password hash must be in the standard sha512 format. # To generate the hash admin_password_hash should be the output from on the management node
# python -c "import crypt; print crypt.crypt('<plaintext password>')"
Step 2 Run the reconfigure commands as follows:
[root@mgmt1 ~]# cd /root/ [root@mgmt1 ~]# mkdir MyDir
[root@mgmt1 ~]# cp /root/openstack-configs/setup_data.yaml /root/MyDir/
# update the setup_data to include vim_admin info
[root@mgmt1 ~]# cd /root/MyDir/
[root@mgmt1 ~]# vi setup_data.yaml [root@mgmt1 ~]# cd ~/installer-xxxx
[root@mgmt1 ~]# ciscovim --setupfile /root/MyDir/setup_data.yaml reconfigure
Reconfigure of Proxy Post Install
During post install one can update the http/https proxy server information listed in NETWORKING section of the setup_data.yaml.
To update the proxy in the post VIM install follow the steps listed below:
Procedure
Step 1 Take a backup of the setupdata file and update the file manually with the configs listed as, http_proxy_server: <a.b.c.d:port> # optional, needed if install is through internet, and the pod is behind a proxy and/or https_proxy_server: <a.b.c.d:port> # optional, needed if install is through internet, and the pod is behind a proxy
Step 2 Run the reconfigure commands follows:
[root@mgmt1 ~]# cd /root/ [root@mgmt1 ~]# mkdir MyDir
[root@mgmt1 ~]# cp /root/openstack-configs/setup_data.yaml /root/MyDir/
# update the setup_data to update the proxy info
[root@mgmt1 ~]# cd /root/MyDir/
[root@mgmt1 ~]# vi setup_data.yaml [root@mgmt1 ~]# cd ~/installer-xxxx
[root@mgmt1 ~]# ciscovim --setupfile /root/MyDir/setup_data.yaml reconfigure
34
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
Managing Cisco NFVI
Updating Containers in a Running Cisco VIM Cloud
Updating Containers in a Running Cisco VIM Cloud
Cisco VIM allows you to update all OpenStack and infrastructure services such as RabbitMQ, MariaDB,
HAProxy, and management node containers such as Cobbler, ELK, VMTP and repo containers with almost no impact to the Cisco NFVI implementation. Updates allows you to integrate Cisco VIM patch releases without redeploying the Cisco NFVI stack from the beginning. Updates have minimal service impact because they run serially component by component one node at a time. If an error occurs during an update, auto-rollback is triggered to return the cloud to its pre-update state. After an update you can check for any functional impacts on the cloud. If everything is fine you can commit the update, which deletes the old containers and old images from the nodes. Should you see any functional cloud impact you can perform a manual rollback to start the old containers again.
Before you begin a container update, keep the following in mind:
• Updates are not supported for registry-related containers and authorized_keys.
• You cannot roll back the repo containers on the management node to an older version after they are updated because rollbacks will delete node packages and might cause the cloud to destabilize.
• To prevent double-faults, a cloud sanity check is performed before the update is started. A cloud sanity check is performed as the last step of the update.
The following table provides an overview to the methods to start the OpenStack update using Cisco VIM.
The Internet options refer to management node connectivity to the Internet. If your management server lacks
Internet access, you must have a staging server with Internet access to download the Cisco VIM installation artifacts to a USB stick. Cisco recommends selecting one method and staying with it for the full pod lifecycle.
Table 2: OpenStack Update Options
Without Cisco VIM Insight With Cisco VIM Insight
Without Internet
• Prepare the USB on a staging server
• Plug the USB into the management node.
• Follow the update steps in the update without Internet procedure.
• Prepare the USB on a staging server
• Plug the USB into the management node.
• Follow the update steps in the update without Internet procedure.
With Internet
• Download the .tgz file from the registry.
• Follow the update steps in the update with Internet procedure.
• Download the .tgz file from the registry.
• Follow the update steps in the update with Internet procedure.
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
35
Managing Cisco NFVI
Updating Cisco VIM Software Using a USB
Updating Cisco VIM Software Using a USB
The following procedure tells you how to load the Cisco VIM installation files onto a Cisco NFVI management node that does not have Internet access. Installation files include: buildnode-K9.iso, mercury-installer.tar.gz, nova-libvirt.tar, registry-2.3.1.tar.gz, and respective checksums..
Before You Begin
This procedure requires a CentOS 7 staging server (VM, laptop, or UCS server) with a 64 GB USB 2.0 stick.
The staging server must have Internet access (wired access is recommended) to download the Cisco VIM installation files, which you will load onto the USB stick. You then use the USB stick to load the installation files onto the management node. The installation files are around 24 GB in size, downloading them to the
USB stick might take several hours, depending on the speed of your Internet connection, so plan accordingly.
Before you begin, disable the CentOS sleep mode.
Procedure
Step 1 On the staging server, use yum to install the following packages:
• PyYAML (yum install PyYAML)
• python-requests (yum install python-requests)
Step 2 Connect to the Cisco VIM software download site using a web browser and login credentials provided by your account representative and download the getartifacts.py
script from external registry.
# download the new getartifacts.py file (see example below) curl -o getartifacts.py
https://<username>:<password>@cvim-registry.com/mercury-releases/mercury-rhel7-osp8/releases/<1.0.1>/getartifacts.py
curl -o getartifacts.py-checksum.txt
https://<username>:<password>@cvim-registry.com/mercury-releases/mercury-rhel7-osp8/releases/1.0.1/getartifacts.py-checksum.txt
# calculate the checksum and verify that with one in getartifacts.py-checksum.txt
sha512sum getartifacts.py
# Change the permission of getartificats.py
chmod +x getartifacts.py
Step 3 Run the getartifacts.py
script. The script formats the USB 2.0 stick and downloads the installation artifacts.
You will need to provide the registry username and password, the tag ID, and the USB partition on the staging server. For example:
To identify the USB drive, execute the lsblk command before and after inserting the USB stick. (The command displays a list of available block devices.) The output delta will help find the USB drive location. Provide the entire drive path in the – d option, instead of any partition.
sudo ./ getartifacts.py -t <tag_id> -u <username> -p <password> -d </dev/sdc>
Note Do not remove the USB stick while the synchronization is under way.
Step 4 Verify the integrity of the downloaded artifacts and the container images:
# create a directory sudo mkdir -p /mnt/Cisco
36
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
Managing Cisco NFVI
Updating Cisco VIM Software Using a USB
# /dev/sdc is the USB drive, same as supplied in get artifacts.py python script sudo mount /dev/sdc1 /mnt/Cisco cd /mnt/Cisco
# execute the verification script
./test-usb
# failures will be explicitly displayed on screen, sample success output below
# sample output of ./test-usb execution with 2.2.x release
[root@mgmtnode Cisco]# ./test-usb
INFO: Checking the integrity of this USB stick
INFO: Checking artifact buildnode-K9.iso
INFO: Checking artifact mercury-version.txt
INFO: Checking artifact registry-2.3.1.tar.gz
INFO: Checking artifact nova-libvirt-K9.tar.gz
INFO: Checking required layers:
INFO: 395 layer files passed checksum.
[root@mgmtnode Cisco]#
Step 5 To resolve download artifact failures, unmount the USB and run the getartifacts command again with the
--retry option: sudo ./getartifacts.py -t <tag_id> -u <username> -p <password> -d </dev/sdc> --retry
Step 6 Mount the USB and then run the test-usb command to validate all the files are downloaded:
# /dev/sdc is the USB drive, same as supplied in get artifacts.py python script sudo mount /dev/sda1 /mnt/Cisco cd /mnt/Cisco
# execute the verification script
./test-usb
# In case of failures the out of the above command will explicitly display the same on the screen
Step 7 After the synchronization finishes, unmount the USB stick: sudo umount /mnt/Cisco
Step 8 After the synchronization finishes, remove the USB stick from the staging server then insert it into the management node.
Step 9 Complete the following steps to import the Cisco NFVI installation artifacts onto the management node: a) Identify the USB on the management node: blkid -L Cisco-VIM b) Mount the USB device on the management node: mount < /dev/sdc > /mnt/ cd /tmp/ c) Extract the import_artifacts.py script: tar --no-same-owner -xvzf /mnt/mercury-installer.tar.gz installer-< xxxx >/ tools/import_artifacts.sh
d) Copy the import_artifacts.py script: cp installer-< xxxx >/tools/import_artifacts.sh /root/ rm -fr /tmp/installer-< xxxx > e) Unmount the USB device: umount /mnt/cd /root/
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
37
Managing Cisco NFVI
Updating Cisco VIM Software Using Network Installation f) Import the artifacts:
./import_artifacts.sh
Step 10 Verify the image version and change ID for the software update.
cat /var/cisco/artifacts/mercury-version.txt
Step 11 Execute the update from the old working directory: cd $old_workspace/installer; ciscovim update --file /var/cisco/artifacts/mercury-installer.tar.gz
After the update is complete, use the newly created directory from here onwards (unless a rollback is planned).
Step 12 Commit the update by running the following command: ciscovim commit # from the new workspace
Step 13 To revert the update changes before entering the commit command, enter: ciscovim rollback # and then use older workspace
Note Do not run any other Cisco VIM actions while the update is underway.
Updating Cisco VIM Software Using Network Installation
Procedure
Step 1 From the download site provided by your Cisco account representative, download the mercury-installer.gz
curl -o mercury-installer.tar.gz
https://{username}:{password}@cvim-registry.cisco.com/ mercury-releases/mercury-rhel7-osp10/releases/{release number}/ mercury-installer.tar.gz
The link to the tar ball above is an example.
Step 2 Execute the update from the old working directory:
Note Do not run any other Cisco VIM actions while the update is underway.
cd /root/installer-<tagid> ciscovim update – file /root/mercury-installer.tar.gz
After the update is complete, use the newly created directory from here onwards (unless a rollback is planned).
Step 3 Commit the update by running the following command: ciscovim commit
Step 4 To revert the update changes before entering the commit command, enter: ciscovim rollback # and then use older workspace
Upgrading Containers in a Running Cisco VIM Cloud
Cisco VIM 2.2 allows you to upgrade all OpenStack services, infrastructure services such as RabbitMQ,
MariaDB, HAProxy, and management node containers such as Cobbler, ELK, VMTP and repo containers.
You can upgrade to new releases of OpenStack without redeploying the Cisco NFVI stack from the beginning.
38
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
Managing Cisco NFVI
Upgrading Containers in a Running Cisco VIM Cloud
During upgrade, you can expect limited service impact as the upgrade is run serially on component by component (one node at a time).
Cisco VIM 2.2 supports upgrade from a known version of VIM running Liberty (1.0.40) to the current version of Newton (2.2.0). As OpenStack does not support the skipping of major releases during upgrade, the VIM upgrade internally moves the stack to Mitaka and then to Newton release of OpenStack.
As part of the VIM cloud upgrade,
• The runner.py script is used to automatically upgrade the REST API server managing the VIM orchestrator.
• The setup_data.yaml is automatically translated so that the setup_data.yaml file is compatible to the target release version.
Before you begin a container update, consider the following points:
• Plan for the downtime as the upgrade involves moving the Kernel version.
• Updates are not supported for registry-related containers and authorized_keys.
• The repo containers on the management node cannot be rolled back to an older version after the upgrade, as the rollbacks will delete the node packages and destabilize the cloud.
• A cloud sanity check is performed before the update is started to prevent double-faults,. A cloud sanity check is performed as the last step of the update.
Before you begin a Pod upgrade, keep the following in mind:
• There is no roll-back in Upgrades, so it is better to stage it in the lab, and test it few times as issues related to specific customer environment might surface.
• The upgrade script, vim_upgrade_orchestrator.py, is available as part of the 2.2 artifacts and needs to be copied to /root/ location before starting the execution.
• For disconnected upgrade, 2 USBs 2.0 (64GB) should be pre-populated with artifacts from 1.5.2 and
2.2.0.
• Upgrade from 1.0.x to 2.2.x is restricted to specific starting and end point.
• Upgrade of the cloud is supported in both connected and disconnected mode.
• In 2.2.x, UCSD is no longer supported, instead the UI has been replaced by VIM Insight; Post Upgrade customer should bring up the Insight service on its own and register the pod to it
• We recommended you not to change the upgrade mode and the install mode.
• Upgrade is a one-way operation ( there no rollback); so planning should be done before executing the upgrade. In the off chance, if one faces an issue, reach out to Cisco TAC/BU to recover the cloud.
At a high level, the upgrade script, vim_upgrade_orchestrator.py, is broken into three steps with logic to abort on fail. In case of failure, it is important to call Cisco support and not recover the cloud on your own.
The following are the three high level steps into which the vim_upgrade_orchestrator.py is broken into:
• Pre-Upgrade Check
◦ Registry connectivity (if connected install).
◦ Setup_data pre check: No UCSM_PLUGIN, sufficient storage pool size.
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
39
Managing Cisco NFVI
Upgrading Containers in a Running Cisco VIM Cloud
◦ Backup setup_data.yaml, before performing translation.
◦ Check and Update INSTALL_MODE in setup_data.yaml (connected or disconnected);
◦ run cloud - sanity from stable/liberty.
◦ Check for reachability to all nodes including compute, controller and storage.
• Upgrade to 1.5.2 (Mitaka):
◦ Delete UCSD instance if its running on the management node.
◦ Delete old version of nova-libvirt on the management node.
◦ Auto-translation of setup_data for Mitaka.
◦ Upgrade to Mitaka.
◦ Check for reachability to all nodes (compute, controller and storage).
• Upgrade to 2.2.0 (Newton).
◦ Upgrade to Newton.
◦ Backup of Management Node.
◦ run cloud- sanity from stable/newton.
◦ Check for reachability to all nodes (compute, controller and storage)
For a cloud running with VTS; additional steps need to be taken at this point, as VTC is not managed by Cisco
VIM.
At a high level listed following are the manual steps:
• Power down the VTS 2.3 master and slave instances.
• Keep the VTS 2.3 XRNC/XRVR master and slave instance running.
• Bring up new VTS 2.5 master and slave instance.
• Login to master and slave VTS 2.5 UI and change admin password.
• Enable the VTS High availability with same assigned VIP IP address in VTS 2.3 deployment.
• Bring up new VTSR 2.5 master and slave instance.
• Login to VTS HA VIP IP address and execute the Underlay Loopback and OSPF Template.
• Power down the VTS 2.3 XRNC/XRVR Master and slave instance before performing vtc upgrade only.
After executing the manual steps, excute the vim_upgrade_orchestrator.py with vtcupgradeonly option to have the VIM cloud working with VTS 2.5.
• Connect to the CIMC of the management node and validate the boot-order list SDCARD as the first choice.
• Power-cycle the management node to complete the management node upgrade.
• Manually move the Pod from Software Raid to Hardware Raid.
40
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
Managing Cisco NFVI
Upgrading VIM Software Using a USB
The following table provides an overview to the methods to start the OpenStack update using Cisco VIM.
The Internet options refer to management node connectivity to the Internet. If your management server lacks
Internet access, you must have a staging server with Internet access to download the Cisco VIM installation artifacts to a USB stick. We recommend you to select one method and stay with it for the full pod lifecycle.
Upgrade Method
Without Internet
Without Cisco VIM Insight
• Prepare 2 USB 2.0 (64G) on a staging server and populate them with 1.5.x and 2.2.0 artifacts.
• Plug both the USB into the management node.
• Copy the vim_upgrade_orchestrator.py and follow the upgrade steps in the upgrade without
Internet procedure.
With Internet Copy the vim_upgrade_orchestrator.py and follow the upgrade steps in the upgrade without Internet procedure
Upgrading VIM Software Using a USB
The following procedure tells you how to load the Cisco VIM installation files onto a Cisco NFVI management node that does not have Internet access. Installation files include: build node-K9.iso, mercury-installer.tar.gz, nova-libvirt.tar, registry-2.3.1.tar.gz, and respective checksums..
Before You Begin
This procedure requires a CentOS 7 staging server (VM, laptop ,or UCS server) with two 64 GB USB 2.0
stick. The staging server must have Internet access(wired access is recommended) to download the Cisco
VIM installation files, which you will load onto the USB stick. You then use the USB stick to load the installation files onto the management node. The installation files are around 24 GB in size, downloading them to the USB stick might take several hours, depending on the speed of your Internet connection, so plan accordingly. Before you begin, disable the CentOS sleep mode.
Procedure
Step 1 On the staging server, use yum to install the following packages:
• PyYAML (yum install PyYAML)
• python-requests (yum install python-requests)
Step 2 Connect to the Cisco VIM software download site using a web browser and login credentials provided by your account representative and download the getartifacts.py
script from external registry.
# download the new getartifacts.py file (see example below) curl -o getartifacts.py
https://<username>:<password>@cvim-registry.com/mercury-releases/mercury-rhel7-osp9/releases/<1.5.2>/getartifacts.py
curl -o getartifacts.py-checksum.txt
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
41
Managing Cisco NFVI
Upgrading VIM Software Using a USB https://<username>:<password>@cvim-registry.com/mercury-releases/mercury-rhel7-osp9/releases/1.5.2/getartifacts.py-checksum.txt
# calculate the checksum and verify that with one in getartifacts.py-checksum.txt sha512sum getartifacts.py
# Change the permission of getartificats.py
chmod +x getartifacts.py
Step 3 Run the getartifacts.py
script. The script formats the USB 2.0 stick and downloads the installation artifacts.
You will need to provide the registry username and password, the tag ID, and the USB partition on the staging server. For example:
To identify the USB drive, execute the lsblk command before and after inserting the USB stick. (The command displays a list of available block devices.) The output delta will help find the USB drive location. Provide the entire drive path in the – d option, instead of any partition.
sudo ./ getartifacts.py -t <tag_id> -u <username> -p <password> -d </dev/sdc>
Note Do not remove the USB stick while the synchronization is under way.
Step 4 Verify the integrity of the downloaded artifacts and the container images:
# create a directory sudo mkdir -p /mnt/Cisco
# /dev/sdc is the USB drive, same as supplied in get artifacts.py python script sudo mount
/dev/sdc1 /mnt/Cisco cd /mnt/Cisco
# execute the verification script
./test-usb
# failures will be explicitly displayed on screen, sample success output below
# sample output of ./test-usb execution with 2.2.x release [root@mgmtnode Cisco]# ./test-usb
INFO: Checking the integrity of this USB stick INFO: Checking artifact buildnode-K9.iso
INFO: Checking artifact mercury-version.txt INFO: Checking artifact registry-2.3.1.tar.gz
INFO: Checking artifact nova-libvirt-K9.tar.gz INFO: Checking required layers:
INFO: 395 layer files passed checksum. [root@mgmtnode Cisco]#
Step 5 To resolve download artifact failures, unmount the USB and run the getartifacts command again with the
--retry option: sudo ./getartifacts.py -t <tag_id> -u <username> -p <password> -d </dev/sdc> --retry
Step 6 Mount the USB and then run the test-usb command to validate all the files are downloaded:
# /dev/sdc is the USB drive, same as supplied in get artifacts.py python script sudo mount /dev/sda1 /mnt/Cisco cd /mnt/Cisco
# execute the verification script
./test-usb
# In case of failures the out of the above command will explicitly display the same on the screen
Step 7 After the synchronization finishes, unmount the USB stick: sudo umount /mnt/Cisco
42
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
Managing Cisco NFVI
Upgrading VIM Software Using a USB
Step 8 After the synchronization finishes, remove the USB stick from the staging server then insert it into the management node.
Step 9 Repeat step 2 to step 8 for pre-population of CVIM 2.2.x artifacts onto the 2 nd
USB
Step 10 Insert the 2 pre-populated USBs into the management node of the pod running 1.0.41.
Step 11 Copy the vim_upgrade_orchestrator.py script available in CVIM 2.2 artifacts in the /root/ folder of the management node of the pod running 1.0.41
Step 12 Execute the update from the /root/ location:
# cd /root/
# ./vim_upgrade_orchestrator.py
– i disconnected [-y] # -y if you don ’ t want any interactive mode
After the upgrade is complete, use the newly created directory from here onwards.
Note Upgrade process takes several hours (> 6 hours), so excute this process in a VNC. Do not run any other Cisco VIM actions while the upgrade is underway.
Step 13 Copy the management node back up created during the upgrade, into a separate server via rsync (refer to chapter 12 for details).
Step 14 Check that the SDCARD is state as priority 1 for the boot order, from the CIMC of the management node. If not, set it accordingly. Reboot the management node, and wait for it to come all the way up.
Step 15 Only if VTS is running on the pod, manually move the VTC to 2.5
Step 16 Execute the update from the /root/ location:
# cd /root/
# ./vim_upgrade_orchestrator.py
– i disconnected -s VTCSSHUSERNAME -p VTCSSHPASSWORD
– vtsupgradeonly [-y]
Note "-y" is if you don't want any interactive mode
Step 17 Manually switch the management node of the pod to Hardware Raid. At a high level following steps need to be followed on the management node:
• Go to CIMC and set HDD as the top boot order.
• Enable the HBA on Bios setting from the CIMC. For procedure details, refer to Setting up the UCS
C-Series Pod section in the 2.2 Install Guide.
• Initiate backup and restore of the management node with the current upgraded image version. For details on how to do it, refer to Chapter 12, where the backup and restore of the management node is listed.
Step 18 Move the pod to Hardware Raid, execute the following:
[root@mgmt1 ~]# cd /root/
[root@mgmt1 ~]# mkdir MyDir
[root@mgmt1 ~]# cd MyDir
[root@mgmt1 ~]# cp /root/openstack-configs/setup_data.yaml <my_setup_data.yaml> to
Update the kickstart line in setup_data in /root/Save/: kickstart: block_storage: storage-flexflash-c240m4.ks
compute: compute-flexflash-c220m4.ks
control: control-flexflash-c220m4.ks
kickstart: control: ucs-b-and-c-series.ks
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
43
Managing Cisco NFVI
Upgrading Cisco VIM Software Using Network Installation compute: ucs-b-and-c-series.ks
block_storage: ucs-b-and-c-series.ks
[root@mgmt1 ~]# ciscovim – -setupfile ~/MyDir/<my_setup_data.yaml> run – perform 1
• Then for each compute node, do a remove, followed by add of the same node; (don't forget to power on the server after the remove); you can do remove followed by add of more than 1 compute node at a time.
• For every storage node, do a remove followed by add of the same node, one at a time (don't forget to power on the server after the remove);
• For every controller node, execute replace controller, one at a time
Upgrading Cisco VIM Software Using Network Installation
Procedure
Step 1 From the download site provided by your Cisco account representative, download the vim_upgrade_orchestrator.py curl -o vim_upgrade_orchestrator.py
https://{username}:{password}@cvim-registry.cisco.com/ mercury-releases/mercury-rhel7-osp10/releases/{release number}/vim_upgrade_orchestrator.py The link to the tar ball above is an example.
Step 2 Execute the upgrade from /root/ directory:
$ cd /root/
$ ./vim_upgrade_orchestrator.py
– i connected
Note Do not run any other Cisco VIM actions while the update is underway.
After the upgrades are complete, use the newly created directory from here onwards
VM Resizing
VM resize is the process of changing the flavor of an existing VM. Thus, using VM resize you can upscale a
VM according to your needs. The size of a VM is indicated by the flavor based on which the VM is launched.
Resizing an instance means using a different flavor for the instance.
By default, the resizing process creates the newly sized instance on a new node, if more than one compute node exists and the resources are available. By default, the software, allows you to change the RAM size,
VDISK size, or VCPU count of an OpenStack instance using nova resize . Simultaneous or individual adjustment of properties for the target VM is allowed. If there is no suitable flavor for the new properties of the VM, you can create a new one.
nova resize [--poll] <server> <flavor>
44
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
Managing Cisco NFVI
Nova Migrate
The resize process takes some time as the VM boots up with the new specifications. For example, the Deploying a Cisco CSR (size in MB) would take approximately 60mins. After the resize process, execute nova resize-confirm <server> to overwrite the old VM image with the new one. If you face any issue, you revert to the old VM using the nova-resize-revert <server> command. to drop the new VM image and use the old one. At this point, you can access the VM through SSH and check if the right image is configured.
Note OpenStack will shutdown the VM before the resize, so you have to plan for a downtime.
Note We recommend you not to resize a vdisk to a smaller value, as there is the risk of losing data.
Nova Migrate
The nova migrate command is used to move an instance from one compute host to another compute host. The scheduler chooses the destination compute host based on the availability of the zone settings. This process does not assume that the instance has shared storage available on the target host.
To initiate the cold migration of the VM, you can execute the following command: nova migrate [--poll] <server>
The VM migration can take a while, as the VM boots up with the new specifications. After the VM migration process, you can execute nova resize-confirm <server>
--to overwrite the old VM image with the new one.. If you face any issue, use the nova-resize-revert <server> command to revert to the old VM image.
At this point, access the VM through SSH and check the right image is configured.
Note OpenStack will shutdown the VM before the migrate, so plan for a downtime .
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
45
Nova Migrate
Managing Cisco NFVI
46
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
C H A P T E R
2
Cisco VIM REST API
The following topics explain how to use the Cisco VIM REST API to manage Cisco NFVI.
•
Overview to Cisco VIM REST API, page 47
•
Cisco VIM REST API Resources, page 48
Overview to Cisco VIM REST API
Cisco VIM provides a Representational State Transfer (REST) API that you can use to install, expand, and update Cisco VIM. Actions you can perform using the RESTful API include:
• Install Cisco VIM on Cisco NFVI pods.
• Add and delete pods to and from Cisco NFVI installations.
• Update Cisco VIM software.
• Replace controller nodes.
• Perform cloud maintenance operations.
• Run cloud validations using Virtual Machine ThroughPut (VMTP), a data path performance measurement tool for OpenStack clouds.
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
47
Cisco VIM REST API Resources
The figure below shows the Cisco VIM REST API flow.
Figure 7: Cisco VIM REST API Flow
Cisco VIM REST API
The Cisco VIM REST API security is provided by the Secure Sockets Layer (SSL) included on the Apache webserver. The Pecan-based web application is called by mod_wsgi, which runs the Rest API server. The
Pecan REST API server requires a username and password to authorize REST API server requests. Apache handles the authorization process, which authorizes the request to access the Pecan web application. You can use the Cisco VIM API to upload a new setup_data.yaml file, and start, stop, and query the state of the installation. You can also use it to manage the cloud, add and remove compute and Ceph nodes, and replace the controller nodes. A REST API to launch VMTP (L2/L3 data plane testing) and CloudPulse is also provided.
The Cisco VIM REST API is enabled by default in the management node, if you are using the supplied Cisco
VIM buildnode.iso. You can access API server on the br_api interface on port 8445. Authentication is enabled by default in the web service.
The API end points can be reached with the following URL format: https://<Management_node_api_ip>:8445
The API endpoint expects a basic authentication which is enabled by default in the management node. The authentication credentials can be found in /opt/cisco/ui_config.json in the management node. Sample ui_config.json contents are as shown below:
{
"Kibana-Url": "http://10.10.10.10:5601",
"RestAPI-Url": "https:// 10.10.10.10:8445",
"RestAPI-Username": "admin",
"RestAPI-Password": "a96e86ccb28d92ceb1df",
"BuildNodeIP": "10.10.10.10"
}
Cisco VIM REST API Resources
Setupdata
REST wrapper for setupdata. Provides methods for listing, creating, modifying and deleting setupdata.
Retrieving the setupdata
48
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
Cisco VIM REST API
Cisco VIM REST API Resources
Resource URI
Verb
GET
Example
JSON Request
GET /v1/setupdata
Accept: application/json
JSON Response
200 OK
Content-Type: application/json
{"setupdatas": [{
"status": "Active",
"name":"GG34",
"uuid": "123"
"meta":{
"user":"root"
},
"jsondata":{
.......
}
}]}
Creating the setupdata
Resource URI
Verb
POST
Example
JSON Request
POST /v1/setupdata
Accept: application/json
{
}
"name":"GG34",
"uuid": "123"
"meta":{
"user":"root"
},
"jsondata":{
.......
}
JSON Response
201 OK
Content-Type: application/json
{
"status": "Active",
"name":"GG34",
"uuid": "123"
"meta":{
URI
/v1/setupdata
URI
/v1/setupdata
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
49
Cisco VIM REST API Resources
}
"user":"root"
},
"jsondata":{
.......
}
400 Bad Request
Content-Type: application/json
{
"debuginfo": null
"faultcode": "Client"
"faultstring": "Error"
}
409 CONFLICT
Content-Type: application/json
{
"debuginfo": null
"faultcode": "Client"
"faultstring": "Error"
}
Retrieving a single setupdata
Resource URI
Verb
GET
URI
/v1/setupdata/(id)
Property: id - the id of the setupdata to be queried.
Example
JSON Request
GET /v1/setupdata/123
Accept: application/json
JSON Response
200 OK
Content-Type: application/json
{
"status": "Active",
"name":"GG34",
"uuid": "123"
"meta":{
"user":"root"
},
"jsondata":{
.......
}
}
404 NOT FOUND
Content-Type: application/json
{
"debuginfo": null
"faultcode": "Client"
"faultstring": "Setupdata could not be found."
}
Updating a setupdata
50
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
Cisco VIM REST API
Cisco VIM REST API
Cisco VIM REST API Resources
Resource URI
Verb
PUT
URI
/v1/setupdata/(id)
Property: id - the id of the setupdata to be updated.
Example
JSON Request
PUT /v1/setupdata/123
Accept: application/json
JSON Response
200 OK
Content-Type: application/json
{
"status": "Active",
"name":"GG34",
},
"jsondata":{
.......
}
"uuid": "123"
"meta":{
"user":"root"
}
404 NOT FOUND
Content-Type: application/json
{
"debuginfo": null
"faultcode": "Client"
"faultstring": "Setupdata could not be found."
}
Deleting a setupdata
Resource URI
Verb URI
DELETE /v1/setupdata/(id)
Property: id - the id of the setupdata to be deleted.
Example
JSON Request
DELETE /v1/setupdata/123
Accept: application/json
JSON Response
204 NO CONTENT
Returned on success
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
51
Cisco VIM REST API
Cisco VIM REST API Resources
404 NOT FOUND
Content-Type: application/json
{
"debuginfo": null
"faultcode": "Client"
"faultstring": "Setupdata could not be found."
}
400 BAD REQUEST
Content-Type: application/json
{
"debuginfo": null
"faultcode": "Client"
"faultstring": "Setupdata cannot be deleted when it is being used by an installation"
}
Install resource
REST wrapper for install. Provides methods for starting, stopping, and viewing the status of the installation process.
Return a list of installation
Resource URI
Verb URI
GET /v1/install
Example
JSON Request
GET /v1/install
Accept: application/json
JSON Response
200 OK
Content-Type: application/json
{"installs": [{
"ceph": "Skipped",
"uuid": "123",
"setupdata": "345",
"vmtpresult": "{
"status": "PASS",
"EXT_NET": []
}",
"baremetal": "Success",
"orchestration": "Success",
"validationstatus": "{
"status": "PASS",
"Software_Validation": [],
"Hardware_Validation": []
}",
"currentstatus": "Completed",
"validation": "Success",
"hostsetup": "Success",
"vmtp": "Skipped"
}]
}
Create an installation
Resource URI
52
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
Cisco VIM REST API
Cisco VIM REST API Resources
Verb
POST
URI
/v1/install
Example
JSON Request
GET /v1/install
Accept: application/js
{
"setupdata": "123",
"stages": [
"validation",
"bootstrap",
"runtimevalidation",
"baremetal",
"orchestration",
"hostsetup",
"ceph",
"vmtp"
]
}
JSON Response
201 CREATED
Content-Type: application/json
{
"ceph": "Skipped",
"uuid": "123",
"setupdata": "345",
"vmtpresult": "{
"status": "PASS",
}",
"EXT_NET": []
"baremetal": "Success",
"orchestration": "Success",
"validationstatus": "{
"status": "PASS",
"Software_Validation": [],
}",
"Hardware_Validation": []
"currentstatus": "Completed",
"validation": "Success",
"hostsetup": "Success",
"vmtp": "Skipped"
}
409 CONFLICT
Content-Type: application/json
{
"debuginfo": null
"faultcode": "Client"
"faultstring": "Install already exists"
}
Retrieve the installation
Resource URI
Verb URI
GET /v1/install/{id}
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
53
Cisco VIM REST API Resources
Property: id - the id of the install to be queried.
Example
JSON Request
GET /v1/install/345
Accept: application/js
JSON Response
200 OK
Content-Type: application/json
{
"ceph": "Skipped",
"uuid": "123",
"setupdata": "345",
"vmtpresult": "{
"status": "PASS",
"EXT_NET": []
}",
"baremetal": "Success",
"orchestration": "Success",
"validationstatus": "{
"status": "PASS",
"Software_Validation": [],
"Hardware_Validation": []
}",
"currentstatus": "Completed",
"validation": "Success",
"hostsetup": "Success",
"vmtp": "Skipped"
}
404 NOT FOUND
Content-Type: application/json
{
"debuginfo": null
"faultcode": "Client"
"faultstring": "Install doesn ’ t exists"
}
Stop the installation
Resource URI
Verb URI
DELETE /v1/install/{id}
Property: id - the id of the install to be stopped.
Example
JSON Request
DELETE /v1/install/345
Accept: application/js
54
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
Cisco VIM REST API
Cisco VIM REST API
Cisco VIM REST API Resources
JSON Response
204 NO CONTENT
Content-Type: application/json
404 NOT FOUND
Content-Type: application/json
{
"debuginfo": null
"faultcode": "Client"
"faultstring": "Install doesn ’ t exists"
}
Nodes
Getting a list of nodes
Resource URI
Verb URI
GET /v1/nodes
Example
JSON Request
Get /v1/nodes
Accept: application/js
JSON Response
200 OK
Content-Type: application/json
{
"nodes": [
[
"status": "Active",
"uuid": "456",
"setupdata": "123",
"node_data": "{
"rack_info": {
"rack_id": "RackA"
},
"cimc_info": {
},
"cimc_ip": "10.10.10.10"
"management_ip": "7.7.7.10"
}",
"updated_at": null,
"mtype": "compute",
"install": "345",
"install_logs": "logurl",
"created_at":"2016-0710T06:17:03.761152",
"name": " compute-1"
}
]
}
Add new nodes
The nodes are in compute or block_storage type. Before adding the nodes to the system, the name of the nodes and other necessary information like cimc_ip and rackid must be updated in the setupdata object. If the setupdata object is not updated, the post call will not allow you to add the node.
Resource URI
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
55
Cisco VIM REST API Resources
Verb
POST
URI
/v1/nodes
Example
JSON Request
POST /v1/nodes
Accept: application/js
{
"name" : "compute-5"
}
JSON Response
201 CREATED
Content-Type: application/json
{
"status": "ToAdd",
"uuid": "456",
"setupdata": "123",
"node_data": "{
"rack_info": {
"rack_id": "RackA"
},
"cimc_info": {
"cimc_ip": "10.10.10.10"
},
"management_ip": "7.7.7.10"
}",
"updated_at": null,
"mtype": "compute",
"install": "345",
"install_logs": "logurl",
"created_at":"2016-0710T06:17:03.761152",
"name": " compute-1"
}
Retrieve information about a particular node
Resource URI
Verb URI
GET /v1/nodes{id}
Property: id - the id of the node to be queried.
Example
JSON Request
POST /v1/nodes
Accept: application/js
JSON Response
200 OK
Content-Type: application/json
56
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
Cisco VIM REST API
Cisco VIM REST API
Cisco VIM REST API Resources
{
"status": "Active",
"uuid": "456",
"setupdata": "123",
"node_data": "{
"rack_info": {
"rack_id": "RackA"
},
"cimc_info": {
},
"cimc_ip": "10.10.10.10"
"management_ip": "7.7.7.10"
}",
"updated_at": null,
"mtype": "compute",
"install": "345",
"install_logs": "logurl",
"created_at":"2016-0710T06:17:03.761152",
"name": " compute-1"
}
404 NOT FOUND
Content-Type: application/json
{
"debuginfo": null
"faultcode": "Client"
"faultstring": "Node doesn ’ t exists"
}
Remove a node
The node that must be deleted must be removed from the setupdata object. Once the setupdata object is updated, you can safely delete of the node. The node object will not be deleted until it calls the remove node backend and succeeds.
Resource URI
Verb URI
DELETE /v1/nodes{id}
Property: id - the id of the node to be removed.
Example
JSON Request
DELETE /v1/nodes/456
Accept: application/js
JSON Response
204 ACCEPTED
Content-Type: application/json
404 NOT FOUND
Content-Type: application/json
{
"debuginfo": null
"faultcode": "Client"
"faultstring": "Node doesn ’ t exists"
}
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
57
Cisco VIM REST API
Cisco VIM REST API Resources
For clearing the database and deleting the entries in the nodes, the delete api is called with special parameters that are passed along with the delete request. The JSON parameters are in the following format.
JSON Request
DELETE /v1/nodes/456
Accept: application/js
{
"clear_db_entry":"True"\
}
JSON Response
204 ACCEPTED
Content-Type: application/json
404 NOT FOUND
Content-Type: application/json
{
"debuginfo": null
"faultcode": "Client"
"faultstring": "Node doesn ’ t exists"
}
Note This is done only if the node is deleted from the REST API database. The failure reason of the node must be rectified manually apart from the API. True is a string and not a boolean in the above line.
Replace a controller
Resource URI
Verb
PUT
URI
/v1/nodes{id}
Property: id - the id of the controller to be replaced.
Example
JSON Request
PUT /v1/nodes/456
Accept: application/js
JSON Response
200 OK
Content-Type: application/json
404 NOT FOUND
Content-Type: application/json
{
"debuginfo": null
"faultcode": "Client"
"faultstring": "Node doesn ’ t exists"
}
Offline validation
REST wrapper does the offline validation of setupdata. This will only do S/W Validation of the input setupdata.
58
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
Cisco VIM REST API
Cisco VIM REST API Resources
Create an offline validation operation
Resource URI
Verb URI
POST /v1/offlinevalidation
Example
JSON Request
POST /v1/offlinevalidation
Accept: application/json
{
"jsondata": ".. .. .."
}
JSON Response
201 CREATED
Content-Type: application/json
{
"status": "NotValidated",
"uuid": "bb42e4ba-c8b7-4a5c-98b3-1f384aae2b69",
"created_at": "2016-02-03T02:05:28.384274",
"updated_at": "2016-02-03T02:05:51.880785",
"jsondata": "{}",
"validationstatus": {
"status": "PASS",
"Software_Validation": [],
"Hardware_Validation": []
}
}
Retrieve the results of offline validation
Resource URI
Verb URI
GET /v1/offlinevalidation
Property: id - the id of the node to be queried.
Example
JSON Request
GET /v1/offlinevalidation/789
Accept: application/json
JSON Response
200 OK
Content-Type: application/json
{
"status": " ValidationSuccess",
"uuid": "bb42e4ba-c8b7-4a5c-98b3-1f384aae2b69",
"created_at": "2016-02-03T02:05:28.384274",
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
59
Cisco VIM REST API Resources
"updated_at": "2016-02-03T02:05:51.880785",
"jsondata": "{}",
"validationstatus": {
"status": "PASS",
"Software_Validation": [],
"Hardware_Validation": []
}
}
Update
Start an update process
Resource URI
Verb URI
POST /v1/update
Parameters:
• fileupload - "tar file to upload"
• filename - "Filename being uploaded"
Example
JSON Request curl -sS -X POST --form
"fileupload=@Test/installer.good.tgz" --form
"filename=installer.good.tgz" https://10.10.10.8445/v1/update
Note This curl request is done as a form request.
JSON Response
200 OK
Content-Type: application/json
{
"update_logs": "logurl",
"update_status": "UpdateSuccess",
"update_filename": "installer-4579.tgz",
"created_at": "2016-07-10T18:33:52.698656",
"updated_at": "2016-07-10T18:54:56.885083"
}
409 CONFLICT
Content-Type: application/json
{
"debuginfo": null
"faultcode": "Client"
"faultstring": "Uploaded file is not in tar format"
}
Rollback an update
Resource URI
Verb URI
60
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
Cisco VIM REST API
Cisco VIM REST API
Cisco VIM REST API Resources
PUT /v1/update
Example
JSON Request
PUT /v1/update
Accept: application/json
{
"action":"rollback"
}
JSON Response
200 OK
Content-Type: application/json
{
"update_logs": "logurl",
"update_status": "ToRollback",
"update_filename": "installer-4579.tgz",
"created_at": "2016-07-10T18:33:52.698656",
"updated_at": "2016-07-10T18:54:56.885083"
}
Commit an update
Resource URI
Verb URI
PUT /v1/update
Example
JSON Request
PUT /v1/update
Accept: application/json
{
"action":"commit"
}
JSON Response
200 OK
Content-Type: application/json
{
"update_logs": "logurl",
"update_status": "ToCommit",
"update_filename": "installer-4579.tgz",
"created_at": "2016-07-10T18:33:52.698656",
"updated_at": "2016-07-10T18:54:56.885083"
}
Retrieve the details of an update
Resource URI
Verb URI
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
61
Cisco VIM REST API
Cisco VIM REST API Resources
GET /v1/update
Example
JSON Request
GET /v1/update
Accept: application/json
JSON Response
200 OK
Content-Type: application/json
{
"update_logs": "logurl",
"update_status": "UpdateSuccess",
"update_filename": "installer-4579.tgz",
"created_at": "2016-07-10T18:33:52.698656",
"updated_at": "2016-07-10T18:54:56.885083"
}
Secrets
Retrieve the list of secrets associated with the OpenStack Setup
You can retrieve the set of secret password associated with the OpenStack setup using the above api. This gives the list of secrets for each service in OpenStack.
Resource URI
Verb URI
GET /v1/secrets
Example
JSON Request
GET /v1/secrets
Accept: application/json
JSON Response
200 OK
Content-Type: application/json
{
"HEAT_KEYSTONE_PASSWORD": "xxxx",
"CINDER_KEYSTONE_PASSWORD": "xxxxx",
… .
… .
"RABBITMQ_PASSWORD": "xxxxx"
}
OpenStack Configs
Retrieve the list of OpenStack configs associated with the OpenStack Setup
You can retrieve the set of OpenStack configs associated with the OpenStack setup using the above api. This gives the current settings of different configs like verbose logging, debug logging for different OpenStack services.
Resource URI
62
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
Cisco VIM REST API
Cisco VIM REST API Resources
Verb
GET
URI
/v1/openstack_config
Example
JSON Request
GET /v1/openstack_config
Accept: application/json
JSON Response
200 OK
Content-Type: application/json
{
"CINDER_DEBUG_LOGGING": false,
"KEYSTONE_DEBUG_LOGGING": false,
… .
… .
"NOVA_VERBOSE_LOGGING": true
}
Version
Retrieve the version of the Cisco Virtualized Infrastructure Manager.
Resource URI
Verb URI
GET /v1/version
Example
JSON Request
GET /v1/version
Accept: application/json
JSON Response
200 OK
Content-Type: application/json
{"version": "1.9.1"}
Health of the Management Node
Retrieve the health of the Management node
This api can be used to retrieve the health of the management node. It checks various parameters like partitions, space and so on.
Resource URI
Verb URI
GET /v1/health
Example
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
63
Cisco VIM REST API
Cisco VIM REST API Resources
JSON Request
GET /v1/health
Accept: application/json
JSON Response
200 OK
Content-Type: application/json
{
"status": "PASS",
"BuildNode Validation": {
"Check Docker Pool Settings": {"status": "Pass", "reason": "None"}
… .
… .
}
}
Hardware Information
REST wrapper to do hardware information of setupdata. This will return the hardware information of all hardware available in the setupdata.
Create a HWinfo operation
Resource URI
Verb URI
GET /v1/hwinfo
Example
JSON Request
POST /v1/hwinfo
Accept: application/json
{
"setupdata":"c94d7973-2fcc-4cd1-832d-453d66e6b3bf"
}
JSON Response
201 CREATED
Content-Type: application/json
{
"status": "hwinfoscheduled",
"uuid": "928216dd-9828-407b-9739-8a7162bd0676",
"setupdata": "c94d7973-2fcc-4cd1-832d-453d66e6b3bf",
"created_at": "2017-03-19T13:41:25.488524",
"updated_at": null,
"hwinforesult": ""
}
Retrieve the results of Hwinfo Operation
Resource URI
Verb URI
GET /v1/hwinfo/{id}
Property: id - the id of the node to be queried.
Example
64
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
Cisco VIM REST API
Cisco VIM REST API Resources
JSON Request
GET /v1/hwinfo/789
Accept: application/json
JSON Response
200 OK
Content-Type: application/json
{
"status": "hwinfosuccess",
"uuid": "928216dd-9828-407b-9739-8a7162bd0676",
"setupdata": "c94d7973-2fcc-4cd1-832d-453d66e6b3bf",
"created_at": "2017-03-19T13:41:25.488524",
"updated_at": "2017-03-19T13:42:05.087491",
"hwinforesult": "{\"172.29.172.73\": {\"firmware\": ………… ..
…………
…………… ..
}
Release mapping Information
This api is used to see the list of Features included and list of options which can be reconfigured in the
Openstack Setup.
Retrieve the release mapping information
Resource URI
Verb URI
GET /v1/releasemapping
JSON Request
GET /v1/releasemapping
Accept: application/json
JSON Response
200 OK
Content-Type: application/json
[
{
"SWIFTSTACK": {
"feature_status": true,
],
"desc": "swift stack feature"
}
}, …… ..
………… ..
}
POST Install operations
The following are the post install operations that can be carried on once the OpenStack installation is carried out successfully. It uses a common api. So only one operation is given as an example below:
1 reconfigure,
2 reconfigure -regenerate passwords
3 reconfigure -setpasswords,setopenstack_configs,
4 check-fernet-keys
5 period-rotate-fernet-keys
6 resync-fernet-keys
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
65
Cisco VIM REST API
Cisco VIM REST API Resources
7 rotate-fernet-keys
Create a post install operation
Resource URI
Verb
POST
URI
/v1/misc
Example
JSON Request
POST /v1/misc
Accept: application/json
{"action": {"reconfigure": true}}
JSON Response
201 CREATED
Content-Type: application/json
{
"uuid": "7e30a671-bacf-4e3b-9a8f-5a1fd8a46733",
"created_at": "2017-03-19T14:03:39.723914",
"updated_at": null,
"operation_status": "OperationScheduled",
"operation_logs": "",
"operation_name": "{"reconfigure": true}"
}
Retrieve a status of the post install operation
Resource URI
Verb URI
GET /v1/misc
Example
JSON Request
GET /v1/misc
Accept: application/json
JSON Response
201 CREATED
Content-Type: application/json
{
"uuid": "7e30a671-bacf-4e3b-9a8f-5a1fd8a46733",
"created_at": "2017-03-19T14:03:39.723914",
"updated_at": "2017-03-19T14:03:42.181180",
"operation_status": "OperationRunning",
"operation_logs": "xxxxxxxxxxxxxxxxx",
"operation_name": "{\"reconfigure\": true}"
}
In VIM 2.2, additional Rest APIs are introduced to support NFVBench, query hardware information and to get a list of optional and mandatory features that the pod supports.
Listed below are the details of the API.
NFVBench Network Performance Testing
66
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
Cisco VIM REST API
Cisco VIM REST API Resources
Create NFVBench Run
Starts network performance test with provided configuration.
REST API To Create Fixed Rate Test
Verb URI
Post v1/nfvbench/ create_ndr_pdr_test
Example
JSON Request
POST Request URL
/v1/nfvbench/create_fixed_rate_test
JSON Request:
{ “ nfvbench_request ” :
{
"duration_sec": 20,
"traffic_profile": [
{
"name": "custom",
"l2frame_size": [
"64",
"IMIX",
"1518"
]
}
],
"traffic": {
"bidirectional": true,
"profile": "custom"
},
"flow_count": 1000
}
}
JSON Response
201 CREATED
Content-Type: application/json
{
"status": "not_run",
"nfvbench_request":
‘ {
"duration_sec": 20,
"traffic_profile": [
{
"name": "custom",
"l2frame_size": [
"64",
"IMIX",
"1518"
]
}
],
"traffic": {
"bidirectional": true,
"profile": "custom"
},
"flow_count": 1000
} ’ ,
"created_at": "2017-08-16T06:14:54.219106",
"updated_at": null,
"nfvbench_result": "",
"test_name": "Fixed_Rate_Test"
}
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
67
Cisco VIM REST API
Cisco VIM REST API Resources
Status Polling
Polling of NFVbench run status which is one of nfvbench_running, nfvbench_failed, nfvbench_completed.
Resource URI
Verb URI
GET v1/nfvbench/<test_name>
REST API To Get Fixed Rate Test Result
GET Request URL
/v1/upgrade/get_fixed_rate_test_result
JSON Response:
Check If NFVbench Test is running
200 OK
Content-Type: application/json
{
"status": "nfvbench_running",
"nfvbench_request": '{"traffic": {"bidirectional": true, "profile": "custom"},
"rate": "1000000pps",
"traffic_profile": [{"l2frame_size": ["1518"], "name": "custom"}], "duration_sec": 60,
"flow_count": 1000}',
"nfvbench_result": ""
"created_at": "2017-05-30T21:40:40.394274",
"updated_at": "2017-05-30T21:40:41.367279",
}
Check If NFVbench Test is completed
200 OK
Content-Type: application/json
{
"status": "nfvbench_completed",
"nfvbench_request": '{"traffic": {"bidirectional": true, "profile": "custom"},
"rate": "1000000pps",
"traffic_profile": [{"l2frame_size": ["1518"], "name": "custom"}], "duration_sec": 60,
"flow_count": 1000}',
"nfvbench_result": '{"status": "PROCESSED", "message": {"date": "2017-08-15 23:15:04",
"nfvbench_version": "0.9.3.dev2", … .}
"created_at": "2017-05-30T21:40:40.394274",
"updated_at": "2017-05-30T22:29:56.970779",
}
REST API to create NDR/PDR Test
POST Request URL
/v1/nfvbench/create_ndr_pdr_test
Accept: application/json
{ “ nfvbench_request ” :
{
"duration_sec": 20,
"traffic_profile": [
{
"name": "custom",
"l2frame_size": [
"64",
"IMIX",
"1518"
]
}
],
"traffic": {
"bidirectional": true,
"profile": "custom"
},
"flow_count": 1000
}
68
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
Cisco VIM REST API
Cisco VIM REST API Resources
}
JSON Response
201 CREATED
Content-Type: application/json
{
"status": "not_run",
“ nfvbench_request ” :
‘ {
"duration_sec": 20,
"traffic_profile": [
{
"name": "custom",
"l2frame_size": [
"64",
"IMIX",
"1518"
]
}
],
"traffic": {
"bidirectional": true,
"profile": "custom"
},
"flow_count": 1000
} ’
"created_at": "2017-08-16T07:18:41.652891",
"updated_at": null,
"nfvbench_result": "",
"test_name": "NDR_PDR_Test"
}
REST API To Get NDR/PDR Test Results
GET Request URL
/v1/ nfvbench/get_ndr_pdr_test_result
JSON Response:
If NFVbench NDR/PDR test is running
200 OK
Content-Type: application/json
{
"status": "nfvbench_running",
"nfvbench_request": '{"duration_sec": 20,
"traffic": {"bidirectional": true, "profile": "custom"},
"traffic_profile": [{"l2frame_size": ["64", "IMIX", "1518"], "name": "custom"}],
"flow_count": 1000}',
"nfvbench_result": ""
"created_at": "2017-08-16T07:18:41.652891",
"updated_at": "2017-09-30T22:29:56.970779",
}
If NFVbench NDR/PDR test is completed
200 OK
Content-Type: application/json
{
"status": "nfvbench_completed",
"nfvbench_request": '{"duration_sec": 20,
"traffic": {"bidirectional": true, "profile": "custom"},
"traffic_profile": [{"l2frame_size": ["64", "IMIX", "1518"], "name": "custom"}], "flow_count":
1000}',
"nfvbench_result": '{"status": "PROCESSED",...}'
"created_at": "2017-08-16T07:18:41.652891",
"updated_at": "2017-09-30T22:29:56.970779",
}
REST API to Get Node Hardware Information
Rest API helps you to get the hardware information of all the nodes in the POD through CIMC/UCSM.
• Total Memory
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
69
Cisco VIM REST API
Cisco VIM REST API Resources
• Firmware Info (Model, Serial Number)
• CIMC IP
GET Request URL
/v1/hwinfo
Output Response
{
"hwinforesult": "{"control-server-2": {"memory": {"total_memory": "131072"},
"firmware": {"serial_number": "FCH1905V16Q", "fw_model": "UCSC-C220-M4S"},
"cimc_ip": "172.31.230.100", "storage": {"num_storage": 4},
"cisco_vic_adapters": {"product_name": "UCS VIC 1225"},
"cpu": {"number_of_cores": "24"}, "power_supply": {"power_state": "on"}}
…
}
REST API to Get Mandatory Features Mapping
POST Request URL
/v1/releasemapping/mandatory_features_mapping
JSON Response:
{
"mandatory": {
"networkType": {
"C": {
"feature_status": true,
"values": [{"name": "VXLAN/Linux Bridge", "value": "VXLAN/Linux Bridge"},],
"insight_label": "Tenant Network",
"desc": "Tenant Network"
},
"B": {
"feature_status": true,
"values": [{"name": "VXLAN/Linux Bridge", "value": "VXLAN/Linux Bridge"},],
"insight_label": "Tenant Network",
"desc": "Tenant Network"
}
},
"cephMode": {
"all": {
"feature_status": true,
"values": [{"name": "Central", "value": "Central"},],
"insight_label": "Ceph Mode",
"desc": "Ceph Mode"
}
},
"podType": {
"C": {
"feature_status": true,
"values": [{"name": "Fullon", "value": "fullon"},],
"insight_label": "POD Type",
"desc": "POD Type"
},
"B": {
"feature_status": true,
"values": [{"name": "Fullon", "value": "fullon"},],
"insight_label": "POD Type",
"desc": "POD Type"
}
},
"installMode": {
"all": {
"feature_status": true,
"values": [{"name": "Connected", "value": "connected"}, ],
"insight_label": "Install Mode",
"desc": "Install Mode"
}
}
},
"platformType": [{"name": "B-series", "value": "B"}, {"name": "C-series", "value":
"C"}],
70
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
Cisco VIM REST API
Cisco VIM REST API Resources
"postinstalllinks": {
"view_cloudpulse": {"alwayson": true, "feature_status": true, "platformtype": "all",
"insight_label": "Run VMTP", "desc": "Cloudpluse"},
"password_reconfigure": {"alwayson": true, "feature_status": true, "platformtype":
}
"all", "insight_label": "Reconfigure Passwords", "desc": "Reconfigure Passwords"}
}
REST API to Get Optional Features Mapping
POST Request URL
/v1/releasemapping/optional_features_mapping
JSON Response:
[
{
"SWIFTSTACK": {
"feature_status": true,
"protocol"],
"desc": "swift stack feature"
}
},
{
"insight_label": "Swiftstack",
"repeated_redeployment": true,
"reconfigurable": ["cluster_api_endpoint", "reseller_prefix", "admin_password",
"heat": {
"feature_status": true,
"insight_label": "Heat",
"repeated_redeployment": false,
}
},
… .. other features
]
"reconfigurable": ["all"],
"desc": "Openstack HEAT service"
Disk Maintenance information
REST wrapper to query information about RAID disks on Pod nodes. This will return the RAID disk information of all or a selection of RAID disks available in the Pod.
The disk management extension to the VIM REST API enables support for Disk Management actions
End Point
/diskmgmt
Type
GET
Valid Args
None
Valid Arg Values
None
Example
/v1/diskmgmt/
/diskmgmt/ check_disks
GET None, args All, control, compute
/diskmgmt/ replace_disks
GET None, args All, control, compute
/v1/diskmgmt/check_disks/
/v1/diskmgmt/check_disks/?
args=control,compute
/v1/diskmgmt/replace_disks/
/v1/diskmgmt/replace_disks/?
args=control,compute
/diskmgmt/server GET server_list, action
List of valid server names, check_disks, replace_disks
/v1/diskmgmt/server/?server_list= srv1,srv2&action=check_disks
/v1/diskmgmt/server/?server_list= srv1&action=replace_disks
Get a Check disk operation
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
71
Cisco VIM REST API Resources
Resource URI
Verb
GET
Example
JSON Request
GET /v1/diskmgmt Accept: application/json
JSON Response
200 OK
Content-Type: application/json
{
"add_as_spares_disks_results_list": [],
"bad_disks_results_list": [],
"fcfg_disks_results_list": [],
"raid_results_list": [
{
"Num PDs": 4,
"Num VDs": 1,
"RAID health": "Opt",
"RAID level": "RAID10",
"RAID type": "HW",
"VD health": "Optl",
"host": "EMC-Testbed",
"role": "management",
"server": "localhost"
},
{
"Num PDs": 4,
"Num VDs": 1,
"RAID health": "Opt",
"RAID level": "RAID10",
"RAID type": "HW",
"VD health": "Optl",
"host": "i13-20",
"role": "control",
"server": "15.0.0.7"
},
{
"Num PDs": 4,
"Num VDs": 1,
"RAID health": "Opt",
"RAID level": "RAID10",
"RAID type": "HW",
"VD health": "Optl",
"host": "i13-21",
"role": "control",
"server": "15.0.0.8"
},
{
"Num PDs": 4,
"Num VDs": 1,
"RAID health": "Opt",
"RAID level": "RAID10",
"RAID type": "HW",
"VD health": "Optl",
"host": "i13-22",
"role": "control",
"server": "15.0.0.5"
},
{
"Num PDs": 4,
"Num VDs": 1,
"RAID health": "Opt",
"RAID level": "RAID10",
URI
/v1/diskmgmt
72
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
Cisco VIM REST API
Cisco VIM REST API
Cisco VIM REST API Resources
"RAID type": "HW",
"VD health": "Optl",
"host": "i13-23",
"role": "compute",
"server": "15.0.0.6"
},
{
"Num PDs": 4,
"Num VDs": 1,
"RAID health": "Opt",
"RAID level": "RAID10",
"RAID type": "HW",
"VD health": "Optl",
"host": "i13-24",
"role": "compute",
"server": "15.0.0.10"
}
],
"rbld_disks_results_list": [],
"spare_disks_results_list": []
}
Get a Check disk operation for compute nodes
Resource URI
Verb
GET
URI
/v1/diskmgmt/check_disks/?args={all,control,compute}
Example
JSON Request
GET /v1/diskmgmt/check_disks/?args=compute
Accept: application/json
JSON Response
200 OK
Content-Type: application/json
{
"add_as_spares_disks_results_list": [],
"bad_disks_results_list": [],
"fcfg_disks_results_list": [],
"raid_results_list": [
{
"Num PDs": 4,
"Num VDs": 1,
"RAID health": "Opt",
"RAID level": "RAID10",
"RAID type": "HW",
"VD health": "Optl",
"host": "i13-23",
"role": "compute",
"server": "15.0.0.6"
},
{
"Num PDs": 4,
"Num VDs": 1,
"RAID health": "Opt",
"RAID level": "RAID10",
"RAID type": "HW",
"VD health": "Optl",
"host": "i13-24",
"role": "compute",
"server": "15.0.0.10"
}
],
"rbld_disks_results_list": [],
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
73
Cisco VIM REST API
Cisco VIM REST API Resources
"spare_disks_results_list": []
}
Post a replace disk operation
Resource URI
Verb
GET
URI
/v1/diskmgmt/replace_disks/?args={all,control,compute}
Example
JSON Request
Get /v1/diskmgmt/replace_disks/?args=compute Accept: application/json
JSON Response
200 OK
Content-Type: application/json
{
"add_as_spares_disks_results_list": [
{
"disk slot": "1",
"host": "i13-21",
"replace status": "Success",
"role": "control",
"server": "15.0.0.8"
}
]
}
Get a check disk operation for a particular server
Resource URI
Verb
GET
URI v1/diskmgmt/server/?server_list={server_list}&action=check_disks
Example
JSON Request
GET
/v1/diskmgmt/server/?server_list=i13-21,i13-23&action=check_disks
Accept: application/json
JSON Response
200 OK
Content-Type: application/json
{
"add_as_spares_disks_results_list": [
{
"disk slot": "1",
"disk state": " UGood",
"host": "i13-21",
"role": "control",
"server": "15.0.0.8"
}
],
"bad_disks_results_list": [],
"fcfg_disks_results_list": [],
"raid_results_list": [
{
"Num PDs": 4,
"Num VDs": 1,
74
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
Cisco VIM REST API
Cisco VIM REST API Resources
}
"RAID health": "NdAtn",
"RAID level": "RAID10",
"RAID type": "HW",
"VD health": "Dgrd",
"host": "i13-21",
"role": "control",
"server": "15.0.0.8"
},
{
"Num PDs": 4,
"Num VDs": 1,
"RAID health": "Opt",
"RAID level": "RAID10",
"RAID type": "HW",
"VD health": "Optl",
"host": "i13-23",
"role": "compute",
"server": "15.0.0.6"
}
],
"rbld_disks_results_list": [],
"spare_disks_results_list": []
Perform a replace disk operation for a particular server
Resource URI
Verb
GET
URI v1/diskmgmt/server/?server_list={server_list}&action={replace_disks}
Example
JSON Request
GET
/v1/diskmgmt/server?server_list=i13-21&action=replace_disks
Accept: application/json
JSON Response
200 OK
Content-Type: application/json
{
"add_as_spares_disks_results_list": [
{
"disk slot": "1",
"host": "i13-21",
"replace status": "Success",
"role": "control",
"server": "15.0.0.8"
}
]
}
OSD Maintenance information
REST wrapper to query information about OSD on Pod storage nodes. This will return the OSD status information of all or a selection of OSDs available in the Pod.
End Point
/osdmgmt
Type
GET
Valid Args
None
Valid Arg Values
None
Example
/v1/osdmgmt/
/osdmgmt/check_osds GET None Detail /v1/osdmgmt/check_osds/
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
75
Cisco VIM REST API
Cisco VIM REST API Resources
End Point osdmgmt/server
Type
GET
Valid Args server_list, action
Valid Arg Values Example
List of valid server names, check_osds, replace_osd, osd_name
/v1/osdmgmt/server/?server_list
=svr1,svr2&action=check_osds
/v1/osdmgmt/server/server_list=svr1&action
=replace_osd&osd_name=osd_name
Get a OSD disk operation
Resource URI
Verb
GET
URI
/v1/osdmgmt
Example
JSON Request
GET
/v1/osdmgmt
Accept: application/json
JSON Response
200 OK
Content-Type: application/json
{
"bad_osds_results_list": [],
"osd_details_results_list": [
{
"All OSD status": "All Good",
"Num OSDs": 5,
"OSD_detail": [
{
"OSD_id": 0,
"OSD_journal": "/dev/sda4",
"OSD_mount": "/var/lib/ceph/osd/ceph-0",
"OSD_name": "osd.0",
"OSD_path": "/dev/sdb1",
"OSD_status": "up",
"slot_id": 2
},
{
"OSD_id": 3,
"OSD_journal": "/dev/sda5",
"OSD_mount": "/var/lib/ceph/osd/ceph-3",
"OSD_name": "osd.3",
"OSD_path": "/dev/sdc1",
"OSD_status": "up",
"slot_id": 3
},
{
"OSD_id": 6,
"OSD_journal": "/dev/sda6",
"OSD_mount": "/var/lib/ceph/osd/ceph-6",
"OSD_name": "osd.6",
"OSD_path": "/dev/sdd1",
"OSD_status": "up",
"slot_id": 4
},
{
"OSD_id": 9,
76
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
Cisco VIM REST API
Cisco VIM REST API Resources
},
{
"OSD_journal": "/dev/sda7",
"OSD_mount": "/var/lib/ceph/osd/ceph-9",
"OSD_name": "osd.9",
"OSD_path": "/dev/sde1",
"OSD_status": "up",
"slot_id": 5
},
{
"OSD_id": 12,
"OSD_journal": "/dev/sda8",
"OSD_mount": "/var/lib/ceph/osd/ceph-12",
"OSD_name": "osd.12",
"OSD_path": "/dev/sdf1",
"OSD_status": "up",
"slot_id": 6
}
],
"host": "i13-27-test",
"role": "block_storage",
"server": "15.0.0.4"
"All OSD status": "All Good",
"Num OSDs": 5,
"OSD_detail": [
{
"OSD_id": 1,
"OSD_journal": "/dev/sda4",
"OSD_mount": "/var/lib/ceph/osd/ceph-1",
"OSD_name": "osd.1",
"OSD_path": "/dev/sdb1",
"OSD_status": "up",
"slot_id": 2
},
{
"OSD_id": 4,
"OSD_journal": "/dev/sda5",
"OSD_mount": "/var/lib/ceph/osd/ceph-4",
"OSD_name": "osd.4",
"OSD_path": "/dev/sdc1",
"OSD_status": "up",
"slot_id": 3
},
{
"OSD_id": 7,
"OSD_journal": "/dev/sda6",
"OSD_mount": "/var/lib/ceph/osd/ceph-7",
"OSD_name": "osd.7",
"OSD_path": "/dev/sdd1",
"OSD_status": "up",
"slot_id": 4
},
{
"OSD_id": 10,
"OSD_journal": "/dev/sda7",
"OSD_mount": "/var/lib/ceph/osd/ceph-10",
"OSD_name": "osd.10",
"OSD_path": "/dev/sde1",
"OSD_status": "up",
"slot_id": 5
},
{
"OSD_id": 13,
"OSD_journal": "/dev/sda8",
"OSD_mount": "/var/lib/ceph/osd/ceph-13",
"OSD_name": "osd.13",
"OSD_path": "/dev/sdf1",
"OSD_status": "up",
"slot_id": 6
}
],
"host": "i13-25",
"role": "block_storage",
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
77
Cisco VIM REST API
Cisco VIM REST API Resources
"server": "15.0.0.11"
},
{
"All OSD status": "All Good",
"Num OSDs": 5,
"OSD_detail": [
{
"OSD_id": 2,
"OSD_journal": "/dev/sda4",
"OSD_mount": "/var/lib/ceph/osd/ceph-2",
"OSD_name": "osd.2",
"OSD_path": "/dev/sdb1",
"OSD_status": "up",
"slot_id": 2
},
{
"OSD_id": 5,
"OSD_journal": "/dev/sda5",
"OSD_mount": "/var/lib/ceph/osd/ceph-5",
"OSD_name": "osd.5",
"OSD_path": "/dev/sdc1",
"OSD_status": "up",
"slot_id": 3
},
{
"OSD_id": 8,
"OSD_journal": "/dev/sda6",
"OSD_mount": "/var/lib/ceph/osd/ceph-8",
"OSD_name": "osd.8",
"OSD_path": "/dev/sdd1",
"OSD_status": "up",
"slot_id": 4
},
{
"OSD_id": 11,
"OSD_journal": "/dev/sda7",
"OSD_mount": "/var/lib/ceph/osd/ceph-11",
"OSD_name": "osd.11",
"OSD_path": "/dev/sde1",
"OSD_status": "up",
"slot_id": 5
},
{
"OSD_id": 14,
"OSD_journal": "/dev/sda8",
"OSD_mount": "/var/lib/ceph/osd/ceph-14",
"OSD_name": "osd.14",
"OSD_path": "/dev/sdf1",
"OSD_status": "up",
"slot_id": 6
}
],
"host": "i13-26",
"role": "block_storage",
"server": "15.0.0.9"
}
]
}
Perform a check OSD operation for a particular server
Resource URI
Verb
GET
URI
/v1/osdmgmt/server/?server_list={server_list}&action={check_osds}
Example
78
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
Cisco VIM REST API
Cisco VIM REST API Resources
JSON Request
GET
/v1/diskmgmt/server/?server_list=i13-26&action=check_osds
Accept: application/json
JSON Response
200 OK
Content-Type: application/json
{
"bad_osds_results_list": [],
"osd_details_results_list": [
{
"All OSD status": "All Good",
"Num OSDs": 5,
"OSD_detail": [
{
"OSD_id": 2,
"OSD_journal": "/dev/sda4",
"OSD_mount": "/var/lib/ceph/osd/ceph-2",
"OSD_name": "osd.2",
"OSD_path": "/dev/sdb1",
"OSD_status": "up",
"slot_id": 2
},
{
"OSD_id": 5,
"OSD_journal": "/dev/sda5",
"OSD_mount": "/var/lib/ceph/osd/ceph-5",
"OSD_name": "osd.5",
"OSD_path": "/dev/sdc1",
"OSD_status": "up",
"slot_id": 3
},
{
"OSD_id": 8,
"OSD_journal": "/dev/sda6",
"OSD_mount": "/var/lib/ceph/osd/ceph-8",
"OSD_name": "osd.8",
"OSD_path": "/dev/sdd1",
"OSD_status": "up",
"slot_id": 4
},
{
"OSD_id": 11,
"OSD_journal": "/dev/sda7",
"OSD_mount": "/var/lib/ceph/osd/ceph-11",
"OSD_name": "osd.11",
"OSD_path": "/dev/sde1",
"OSD_status": "up",
"slot_id": 5
},
{
"OSD_id": 14,
"OSD_journal": "/dev/sda8",
"OSD_mount": "/var/lib/ceph/osd/ceph-14",
"OSD_name": "osd.14",
"OSD_path": "/dev/sdf1",
"OSD_status": "up",
"slot_id": 6
}
],
"host": "i13-26",
"role": "block_storage",
"server": "15.0.0.9"
}
]
}
Perform a replace OSD operation for a particular server
Resource URI
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
79
Cisco VIM REST API
Cisco VIM REST API Resources
Verb
GET
URI
/v1/osdmgmt/server/?server_list={server_name}&action=replace_osd&osd_name={osd_name}
Example
JSON Request
GET
/v1/diskmgmt/server/?server_list=i13-25&action=replace_osd&osd_name=osd.10
Accept: application/json
JSON Response
200 OK
Content-Type: application/json
{
'osd_replace_details_results_list': [
{ 'hdd_slot': 5,
'host_name': 'i13-25',
'journal_mnt': '/dev/sda4',
'new_dev_uuid': 'UUID=94480b3e-5698-4d6a-b715-0613be41cff5',
'new_mount': '/var/lib/ceph/osd/ceph-10',
'new_osd_id': 10,
'new_path': '/dev/sde1',
'old_osd_id': 10,
'status_msg': 'Successfully deleted, removed and replaced OSD osd.10 from server i13-25'
}
]
}
80
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
C H A P T E R
3
Monitoring Cisco NFVI Performance
The following topics tell you how to display logs to monitor Cisco VIM performance.
•
Logging and Monitoring in Cisco NFVI, page 81
•
Displaying Cisco VIM Log Files Using the CLI, page 84
•
Logging Into the Kibana Dashboard, page 85
•
Rotation of the Cisco VIM Logs, page 94
•
Network Performance Test with NFVBench, page 94
Logging and Monitoring in Cisco NFVI
Cisco VIM uses a combination of open source tools to collect and monitor the Cisco OpenStack services including Elasticsearch, Fluentd, and the Kibana dashboard (EFK).
In VIM 2.2, we have moved our platform to use Fluentd, instead of logstash. However, to maintain backwards compatibility, the code and documentation refers to ELK, instead of EFK at various places. In VIM 2.2, these two acronyms are interchangeable, however it refers to the presence of EFK in the offering. OpenStack servicesthat are tracked by EFK include:
• MariaDB — A relational database management system based on MySQL. All the OpenStack components store their data in MariaDB.
• HAProxy — HAProxy is a free open source software that provides a high-availability load balancer, and proxy server for TCP and HTTP-based applications that spreads requests across multiple servers.
• Keystone — Keystone is an OpenStack project that provides identity, token, catalog, and policy services for use specifically by projects in the OpenStack.
• Glance — An OpenStack project that allows you to upload and discover data assets meant for use with other services.
• Neutron — An OpenStack project that provides network connectivity between interface devices, such as vNICs, managed by other OpenStack services, such as Nova.
• Nova — An OpenStack project designed to provide massively scalable, on demand, self-service access to compute resources.
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
81
Monitoring Cisco NFVI Performance
Logging and Monitoring in Cisco NFVI
• HTTPD — The Apache HTTP Server Project, an effort to develop and maintain an open-source HTTP server.
• Cinder — An OpenStack block storage service designed to present storage resources to end users that are consumed by the OpenStack compute project (Nova).
• Memcached — A general purpose distributed memory caching system.
• CloudPulse — Is an OpenStack tool that checks the health of the cloud. CloudPulse includes operator and endpoint tests.
• Heat — The main OpenStack Orchestration program. Heat implements an orchestration engine to launch multiple composite cloud applications based on text file templates.
• Other OpenStack services — RabbitMQ, Ceph, Open vSwitch, Linux bridge, Neutron VTS (optional), and others.
• VMTP — Integrated control and data plane log for testing the cloud.
• NFVbench — Network performance benchmarking tool.
82
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
Monitoring Cisco NFVI Performance
Logging and Monitoring in Cisco NFVI
A Fluentd container resides on each control, compute, and storage nodes. They forward logs to the Fluentd-aggr server residing on the management node. The following figure shows a high-level schematic of the Fluent service assurance architecture.
Figure 8: EFK Service Assurance Architecture
The EFK flow includes:
• Fluentd extracts the relevant data from the logs and tags them so that they will be used by later Kibana to display useful information about those logs
• Fluentd sends the logs from all the compute, controller, and storage nodes to the Fluentd-aggr server on the management node.
• Fluentd-aggr in the management node sends the structured logs into the Elasticsearch database.
• Elasticsearch stores the data, indexes it, and supports extremely fast queries against a large amount of log data
• Kibana visualizes the data stored in Elasticsearch using a custom dashboards with REST API calls to
Elasticsearch. User can also add filters to the data to visualize interesting fragments of the log data.
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
83
Monitoring Cisco NFVI Performance
Displaying Cisco VIM Log Files Using the CLI
Displaying Cisco VIM Log Files Using the CLI
Cisco VIM log file location depends on the node and log type. Installer logs can be found on the management node under /var/log/mercury/<install_uuid>/ directory. The last twenty log directories are tarred and kept in this directory. These files contain logs related to bootstrap, buildorchestration, baremetal, common setup, and
OpenStack orchestration. If the installer fails, look at the last tar.gz file for logs, for example:
[root@mgmtnode mercury]# ls -lrt total 20 drwxr-xr-x. 2 root root 80 Jul 19 23:42 573f2b7f-4463-4bfa-b57f-98a4a769aced drwxr-xr-x. 2 root root 4096 Jul 20 03:29 installer drwxr-xr-x. 2 root root 79 Jul 20 03:29 e9117bc5-544c-4bda-98d5-65bffa56a18f drwxr-xr-x. 2 root root 79 Jul 20 04:54 36cdf8b5-7a35-4e7e-bb79-0cfb1987f550 drwxr-xr-x. 2 root root 79 Jul 20 04:55 bd739014-fdf1-494e-adc0-98b1fba510bc drwxr-xr-x. 2 root root 79 Jul 20 04:55 e91c4a6c-ae92-4fef-8f7c-cafa9f5dc1a3 drwxr-xr-x. 2 root root 79 Jul 20 04:58 1962b2ba-ff15-47a6-b292-25b7fb84cd28 drwxr-xr-x. 2 root root 79 Jul 20 04:59 d881d453-f6a0-448e-8873-a7c51d8cc442 drwxr-xr-x. 2 root root 78 Jul 20 05:04 187a15b6-d425-46a8-a4a2-e78b65e008b6 drwxr-xr-x. 2 root root 4096 Jul 20 06:47 d0346cdd-5af6-4058-be86-1330f7ae09d1 drwxr-xr-x. 2 root root 79 Jul 20 17:09 f85c8c6c-32c9-44a8-b649-b63fdb11a79a drwxr-xr-x. 2 root root 67 Jul 20 18:09 179ed182-17e4-4f1f-a44d-a3b6c16cf323 drwxr-xr-x. 2 root root 68 Jul 20 18:13 426cb05f-b1ee-43ce-862d-5bb4049cc957 drwxr-xr-x. 2 root root 68 Jul 20 18:13 1d2eec9d-f4d8-4325-9eb1-7d96d23e30fc drwxr-xr-x. 2 root root 68 Jul 20 18:13 02f62a2f-3f59-46a7-9f5f-1656b8721512 drwxr-xr-x. 2 root root 68 Jul 20 18:14 c7417be9-473e-49da-b6d0-d1ab8fb4b1fc drwxr-xr-x. 2 root root 68 Jul 20 18:17 b4d2077b-c7a9-46e7-9d39-d1281fba9baf drwxr-xr-x. 2 root root 68 Jul 20 18:35 21972890-3d45-4642-b41d-c5fadfeba21a drwxr-xr-x. 2 root root 80 Jul 20 19:17 d8b1b54c-7fc1-4ea6-83a5-0e56ff3b67a8 drwxr-xr-x. 2 root root 80 Jul 20 19:17 23a3cc35-4392-40bf-91e6-65c62d973753 drwxr-xr-x. 2 root root 80 Jul 20 19:17 7e831ef9-c932-4b89-8c81-33a45ad82b89 drwxr-xr-x. 2 root root 80 Jul 20 19:18 49ea0917-f9f4-4f5d-82d9-b86570a02dad drwxr-xr-x. 2 root root 80 Jul 20 19:18 21589a61-5893-4e30-a70e-55ad0dc2e93f drwxr-xr-x. 2 root root 80 Jul 20 19:22 6ae6d136-7f87-4fc8-92b8-64cd542495bf drwxr-xr-x. 2 root root 4096 Jul 20 19:46 1c6f4547-c57d-4dcc-a405-ec509306ee25 drwxr-xr-x. 2 root root 68 Jul 20 21:20 c6dcc98d-b45b-4904-a217-d25001275c85 drwxr-xr-x. 2 root root 68 Jul 20 21:40 ee58d5d6-8b61-4431-9f7f-8cab2c331637 drwxr-xr-x. 2 root root 4096 Jul 20 22:06 243cb0f8-5169-430d-a5d8-48008a00d5c7 drwxr-xr-x. 2 root root 4096 Jul 20 22:16 188d53da-f129-46d9-87b7-c876b1aea70c
On controller and compute nodes, all services are run within their respective Docker ™ containers. To list the
Docker containers in the node, execute the following:
[root@control-server-2 ~]# docker ps -a
CONTAINER ID IMAGE COMMAND
258b2ca1d46a
CREATED STATUS PORTS NAMES
172.31.228.164:5000/mercury-rhel7-osp8/nova-scheduler:4780
"/usr/bin/my_init /no" 25 minutes ago Up 25 minutes ffe70809bbe0 novascheduler_4780
172.31.228.164:5000/mercury-rhel7-osp8/nova-novncproxy:4780
"/usr/bin/my_init /st" 25 minutes ago Up 25 minutes novanovncproxy_4780
12b92bcb9dc0 172.31.228.164:5000/mercury-rhel7-osp8/nova-consoleauth:4780
"/usr/bin/my_init /st" 26 minutes ago Up 26 minutes
…… novaconsoleauth_4780
7295596f5167 172.31.228.164:5000/mercury-rhel7-osp8/nova-api:4780
"/usr/bin/my_init /no" 27 minutes ago Up 27 minutes novaapi_4780
To view the Docker logs of any container, execute the following on the corresponding host: ls – l /var/log/<service_name>/<log_filename> e.g. ls -l /var/log/keystone/keystone.log
To get into a specific container, execute the following:
[root@control-server-2 ~]# alias | grep container root@control-server-2 ~]# source /root/.bashrc
#execute the alias:
[root@control-server-2 ~]# novaapi novaapi_4761 [nova@control-server-2 /]$
84
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
Monitoring Cisco NFVI Performance
Logging Into the Kibana Dashboard novaapi_4761 [nova@control-server-2 /]$ exit exit
If the Docker status indicates a container is down (based on output of “ docker ps – a ” ), collect the Docker service logs as well: cd /etc/systemd/system/multi-user.target.wants/ ls docker* # get the corresponding service name from the output systemctl status <service_name> -n 1000 > /root/filename # redirects the output to the file
For storage nodes running Ceph, execute the following to check the cluster status: ceph – v # on monitor nodes (controller), show ’ s ceph version ceph – s # on monitor nodes (controller), show cluster status ceph osd lspools #on monitor nodes (controller),list pools ceph mon stat # summarize monitor status ceph-disk list # on OSD / storage nodes; List disks, partitions, and Ceph OSDs rbd list images # on monitor nodes (controller); dump list of image snapshots rbd list volumes # on monitor nodes (controller); dump list of volumes
Logging Into the Kibana Dashboard
Kibana is an open source data visualization platform that you can use to explore Cisco VIM logs.
To log into the Kibana dashboard:
Procedure
Step 1 Using a terminal client, use SSH to log into your management node and enter the password to login. In the example below, the management node has an IP address of 17.0.0.2:
# ssh [email protected]
[email protected]'s password
Step 2 In the SSH terminal session, locate the line containing ELK_PASSWORD in /root/installer-{tag id}/openstack-configs/secrets.yaml. Note the value of the ELK_PASSWORD. It will be used in Step 4.
cat /root/installer-{tag-id}/openstack-configs/secrets.yaml
...
ELK_PASSWORD: <note this value>
...
Step 3 Using your web browser, navigate to http://<management_node_ip_address>:5601.
Step 4 When prompted, log in with the following credentials:
User Name: admin
Password: <value of ELK_PASSWORD from Step 2>
The Kibana dashboard appears allowing you to display the Cisco VIM service and installer logs.
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
85
Logging Into the Kibana Dashboard
Figure 9: Editing New Dashboard
Monitoring Cisco NFVI Performance
86
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
Monitoring Cisco NFVI Performance
Logging Into the Kibana Dashboard
Step 5 Navigate to the dashboards by clicking Dashboard menu bar and choose the desired dashboard. It is not recommended to use visualize/Timelion/DevTools or Management options on the left side.
Figure 10: Lists of Dashboards
The following are the list of dashboards supported:
• Hostlogs Dashboard: Provides log information of the system for the cloud nodes. This displays entries from the host logs-* index in Elasticsearch. It contains the log from /var/log/messages file on each server.
• Installer Dashboard: Provides information about the management node and the installation process. It can only read uncompressed files. Hence, it reads the files prior to the cloud installation. This displays entries from the installer-* index in Elasticsearch.
• OpenStack Dashboard: (openstack-* index) Provides log information about all the OpenStack processes.
This displays entries from the openstack-* index in Elasticsearch.
• VMTP Dashboard: Provides log information about the VMTP runs performed against the cloud. It displays entries from the vmtp-* index in Elasticsearch
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
87
Monitoring Cisco NFVI Performance
Logging Into the Kibana Dashboard
For Example: if you click on the OpenStack dashboard link the following screen appears.
Figure 11: OpenStack Dashboard
You can switch on from one dashboard to another by selecting the appropriate dashboard from the right top bar menu.
All dashboards have generic and specific fields.
The generic ones are:
• Title: Title is seen at the top left of the page. Title shows which dashboard is being displayed. For
Example: OpenStack Dashboard.
• Time: Time is seen at the top right of the page. Time indicates the time schedule for the log information.
You can modify the time to indicate absolute, relative time in the past or specify automatically refresh rates.
• Search bar: Search bar is an input field where you can enter a query in the Lucene syntax format to filter the logs by specific fields (which depend on the fields for the index being selected)
• Add a filter tab: Use this tab to introduce filters graphically.
For more information on using Kibana, see the Kibana documentation (Version 5.5.1).
Cisco VIM stores the OpenStack logs in Elasticsearch. The Elasticsearch snapshots all the indices (where the data is stored) which are rotated on a periodic basis. You may not see the older data in Kibana if the data is rotated out and/or deleted.
88
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
Monitoring Cisco NFVI Performance
Logging Into the Kibana Dashboard
Logs keep being visualized in Kibana as they are being updated in Elasticsearch on the Discover tab. To debug something on kibana, you can program the Kibana dashboard to auto-refresh at specific intervals (by default is off). To enable auto-refresh, click the date at the top right corner of the dashboard and click Auto-refresh to configure the desired value.
Figure 12: Auto-Refresh
User can click the play/pause button on the top navigator bar to continue/pause the refreshing of logs events: a) Few examples on usage of filters in Openstack dashboard to gather useful information
• ◦ On the Hostlogs Dashboard, in the Events by Host panel, choose a hostname and click the + or - symbol that appears close to the hostname to include or exclude that server from the filter.
Then, click the desired slice on the Events By Service panel to add the docker service to the section.
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
89
Monitoring Cisco NFVI Performance
Logging Into the Kibana Dashboard
◦ Under the Search field, you will see the included sections in green and excluded sections in red.
Figure 13: Hostlogs Dashboard
90
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
Monitoring Cisco NFVI Performance
Logging Into the Kibana Dashboard b) To know the log events in the Openstack for a given VM by writing the filter directly on the Search field:
Note The uuid of the VM can be identified by executing openstack nova list or looking at the horizon website.
• In the Search field which is on top of the Dashboard, write the following Lucene query: (service: nova and service: neutron) AND (message:<uuid>) here, <uuid> is the number got from Horizon or nova list for the identifier of the instance VM.
Figure 14: Search Query Page
• For example, if the user wants to know the DHCP events of the Openstack Neutron add filters by clicking outer circle of pie chart::
◦ On the OpenStack Dashboard, the Openstack - Events By Service panel has a pie chart with the inner section for the services and the outer sections for the service_subtypes. To add filters for selecting all the events in a service (for example, neutron), click on the inner section of the
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
91
Monitoring Cisco NFVI Performance
Logging Into the Kibana Dashboard pie. To add filters for selecting the service_subtypes (for example, dhcp), click on the outer circle of the pie.
Figure 15: Events by Service
◦ Note: You can scroll down the OpenStack Dashboard to see the OpenStack - Errors and the
OpenStack - Events panel.. The OpenStack - Errors panel displays the error messages. If there are no errors, the No results found message is displayed.
92
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
Monitoring Cisco NFVI Performance
Logging Into the Kibana Dashboard
◦ Without knowing the Lucene Syntax, you can set the filter criteria in the Search field using the Add a filter + option.
Following are the steps to add a filter:
◦ Click Add a filter (+).
◦ Set the filter criteria by choosing appropriate label and operators from the drop-down lists, and entering keywords and click Save.
Figure 16: Add Filters Page
Set the filter criteria by choosing appropriate label and operators from the drop-down lists, and entering keywords.
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
93
Rotation of the Cisco VIM Logs
Figure 17: Choosing Appropriate Labels
Monitoring Cisco NFVI Performance
Rotation of the Cisco VIM Logs
Cisco VIM stores all logs in Elasticsearch. Elasticsearch indices are rotated on a periodic basis to prevent disk space overflow by creating snapshots. Snapshots are defined in openstack_config.yaml as listed below:
# vi ~/openstack-configs/openstack_config.yaml
…
# Elk rotation parameters elk_rotation_frequency: "monthly" # Available: "daily", "weekly", "fortnightly", "monthly" elk_rotation_size: 2 # Unit is in Gigabytes (float is allowed) elk_rotation_del_older: 10 # Delete older than 10 units (where units depends on the
… value set on elk_rotation_frequency)
You can change the frequency of the rotation by changing the values. For more information on how to set the
Elasticsearch parameters via VIM API/CLI, please refer to the section Reconfiguring Passwords and OpenStack
Configurations .
Cisco VIM uses the open source Elasticsearch Curator tool to manage the Elasticsearch indices and snapshots.
For more information about Elasticsearch handles snapshots, please look at the official information on Elastic.co
(version 5.2) .
Network Performance Test with NFVBench
NFVBench is a network performance benchmarking tool integrated with Cisco VIM. For more details, refer to NFVBench section of Chapter 1 in the admin guide for details.
94
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
C H A P T E R
4
Managing Cisco NFVI Security
The following topics describe Cisco NFVI network and application security and best practices.
•
Verifying Management Node Network Permissions , page 95
•
Verifying Management Node File Permissions, page 96
•
Viewing Administrator Access Attempts, page 96
•
•
Validating Port Listening Services, page 97
•
Validating Non-Root Users for OpenStack Services, page 98
•
Verifying Password Strength, page 98
•
Reconfiguring Passwords and OpenStack Configurations, page 99
•
Reconfiguring CIMC Password on an Existing Install, page 102
•
Increasing Provider and Tenant VLAN Ranges, page 103
•
Enabling NFVIMON Post Pod Install, page 103
•
Fernet Key Operations , page 105
•
Managing Certificates, page 106
•
Enabling TLS post install, page 106
•
Reconfiguring TLS Certificates, page 107
•
Enabling Keystone v3 on an Existing Install, page 108
Verifying Management Node Network Permissions
The Cisco NFVI management node stores sensitive information related to Cisco NFVI operations. Access to the management node can be restricted to requests coming from IP addresses known to be used by administrators. The administrator source networks is configured in the setup file, under [NETWORKING] using the admin_source_networks parameter. To verify this host based firewall setting, log into the management node as an admin user and list the rules currently enforces by iptables. Verify that the source
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
95
Managing Cisco NFVI Security
Verifying Management Node File Permissions networks match the values configured. If no source networks have been configured, then all source traffic is allowed. However, note that only traffic destined to ports with known admin services is allowed to pass. The admin_source_networks value can be set at install time or changed through a reconfigure.
[root@j11-control-server-1 ~]# iptables – list
Chain INPUT (policy ACCEPT) target
ACCEPT
ACCEPT
ACCEPT prot opt source icmp -anywhere tcp -10.0.0.0/8 tcp -172.16.0.0/12 destination anywhere anywhere anywhere
ACCEPT
ACCEPT
ACCEPT
ACCEPT
ACCEPT
ACCEPT
ACCEPT tcp tcp tcp tcp tcp tcp tcp
--
--
--
--
--
--
--
10.0.0.0/8
172.16.0.0/12
10.0.0.0/8
172.16.0.0/12
10.0.0.0/8
172.16.0.0/12
10.0.0.0/8 anywhere anywhere anywhere anywhere anywhere anywhere anywhere
ACCEPT
ACCEPT
ACCEPT
ACCEPT
ACCEPT
ACCEPT
DROP tcp -172.16.0.0/12 tcp -10.0.0.0/8 tcp -172.16.0.0/12 tcp -10.0.0.0/8 tcp -172.16.0.0/12 all -anywhere all -anywhere anywhere anywhere anywhere anywhere anywhere anywhere anywhere tcp dpt:ssh tcp dpt:ssh tcp dpt:https tcp dpt:https tcp dpt:4979 tcp dpt:4979 tcp dpt:esmagent tcp dpt:esmagent tcp dpt:8008 tcp dpt:8008 tcp dpt:copy tcp dpt:copy tcp dpt:22250 tcp dpt:22250 state RELATED,ESTABLISHED
Verifying Management Node File Permissions
The Cisco NFVI management node stores sensitive information related to Cisco NFVI operations. These files are secured by strict file permissions. Sensitive files include secrets.yaml, openrc, *.key, and *.pem. To verify the file permissions, log into the management node as an admin user and list all of the files in the
~ /openstack-configs/ directory. Verify that only the owner has read and write access to these files. For example:
[root@j11-control-server-1 ~]# ls – l ~/openstack-configs total 172
-rw-------. 1 root root 3272 Jun 21 17:57 haproxy.key
-rw-------. 1 root root 5167 Jun 21 17:57 haproxy.pem
-rw-------. 1 root root 223 Aug 8 18:09 openrc
-rw-------. 1 root root 942 Jul 6 19:44 secrets.yaml
[ … ]
Viewing Administrator Access Attempts
Because the UCS servers are part of the critical Cisco NFVI infrastructure, Cisco recommends monitoring administrator login access periodically. To view the access attempts, use the journalctl command to view the log created by sshd. For example:
[root@control-server-1 ~]# journalctl – u sshd
-- Logs begin at Tue 2016-06-21 17:39:35 UTC, end at Mon 2016-08-08 17:25:06 UTC. --
Jun 21 17:40:03 hh23-12 systemd[1]: Started OpenSSH server daemon.
Jun 21 17:40:03 hh23-12 systemd[1]: Starting OpenSSH server daemon...
Jun 21 17:40:03 hh23-12 sshd[2393]: Server listening on 0.0.0.0 port 22.
Jun 21 17:40:03 hh23-12 sshd[2393]: Server listening on :: port 22.
Jun 21 17:40:43 hh23-12 sshd[12657]: Connection closed by 171.70.163.201 [preauth]
Jun 21 17:41:13 hh23-12 sshd[12659]: Accepted password for root from 171.70.163.201 port
40499
Jun 21 17:46:41 hh23-12 systemd[1]: Stopping OpenSSH server daemon...
Jun 21 17:46:41 hh23-12 sshd[2393]: Received signal 15; terminating.
Jun 21 17:46:41 hh23-12 systemd[1]: Started OpenSSH server daemon.
Jun 21 17:46:41 hh23-12 systemd[1]: Starting OpenSSH server daemon...
Jun 21 17:46:41 hh23-12 sshd[13930]: Server listening on 0.0.0.0 port 22.
Jun 21 17:46:41 hh23-12 sshd[13930]: Server listening on :: port 22.
96
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
Managing Cisco NFVI Security
Verifying SELinux
Jun 21 17:50:45 hh23-12 sshd[33964]: Accepted password for root from 171.70.163.201 port
40545
Jun 21 17:56:36 hh23-12 sshd[34028]: Connection closed by 192.168.212.20 [preauth]
Jun 21 17:57:08 hh23-12 sshd[34030]: Accepted publickey for root from 10.117.212.20 port
62819
Jun 22 16:42:40 hh23-12 sshd[8485]: Invalid user user1 from 10.117.212.20
Jun 22 16:42:40 hh23-12 sshd[8485]: input_userauth_request: invalid user user1 [preauth] s
Verifying SELinux
To minimize the impact of a security breach on a Cisco NFVI server, the Cisco VM enables SELinux (Security
Enhanced Linux) to protect the server resources. To validate that SELinux is configured and running in enforcing mode, use the sestatus command to view the status of SELinux and verify that its status is enabled and in enforcing mode. For example:
[root@mgmt1 ~]# /usr/sbin/sestatus -v
SELinux status:
SELinuxfs mount:
SELinux root directory: enabled
/sys/fs/selinux
/etc/selinux
Loaded policy name:
Current mode:
Mode from config file:
Policy MLS status:
Policy deny_unknown status:
Max kernel policy version: targeted enforcing permissive enabled allowed
28
Validating Port Listening Services
To prevent access by unauthorized users and processes, Cisco NFVI has no extra services listening on network ports. To verify this, use the netstat -plnt command to get a list of all services listening on the node and verify that no unauthorized services are listening. For example:
[root@j11-control-server-1 ~]# netstat -plnt
Active Internet connections (only servers)
Proto Recv-Q Send-Q Local Address name
Foreign Address tcp tcp tcp
0
0
0
0 23.23.4.101:8776
0 23.23.4.101:5000
0 23.23.4.101:5672
0.0.0.0:*
0.0.0.0:*
0.0.0.0:*
State
LISTEN
LISTEN
LISTEN
PID/Program
24468/python2
19874/httpd
18878/beam.smp
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0 tcp tcp tcp tcp tcp tcp tcp tcp tcp tcp tcp tcp tcp tcp tcp
0 23.23.4.101:3306
0 127.0.0.1:11211
0 23.23.4.101:11211
0 23.23.4.101:9292
0 23.23.4.101:9999
0 23.23.4.101:80
0 0.0.0.0:4369
0 127.0.0.1:4243
0 0.0.0.0:22
0 23.23.4.101:4567
0 23.23.4.101:15672
0 0.0.0.0:35672
0 127.0.0.1:25
0 23.23.4.101:35357
0 23.23.4.101:8000
0.0.0.0:*
0.0.0.0:*
0.0.0.0:*
0.0.0.0:*
0.0.0.0:*
0.0.0.0:*
0.0.0.0:*
0.0.0.0:*
0.0.0.0:*
0.0.0.0:*
0.0.0.0:*
0.0.0.0:*
0.0.0.0:*
0.0.0.0:*
0.0.0.0:*
LISTEN
LISTEN
LISTEN
LISTEN
LISTEN
LISTEN
LISTEN
LISTEN
LISTEN
LISTEN
LISTEN
LISTEN
LISTEN
LISTEN
LISTEN
18337/mysqld
16563/memcached
16563/memcached
21175/python2
28555/python
28943/httpd
18897/epmd
14673/docker
2909/sshd
18337/mysqld
18878/beam.smp
18878/beam.smp
4531/master
19874/httpd
30505/python
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
97
Managing Cisco NFVI Security
Validating Non-Root Users for OpenStack Services tcp tcp tcp tcp tcp tcp tcp tcp6 tcp6 tcp6 tcp6
0
0
0
0
0
0
0
0
0
0
0
0 23.23.4.101:6080
0 23.23.4.101:9696
0 23.23.4.101:8004
0 23.23.4.101:8773
0 23.23.4.101:8774
0 23.23.4.101:8775
0 23.23.4.101:9191
0 :::9200
0 :::4369
0 :::22
0 ::1:25
0.0.0.0:*
0.0.0.0:*
0.0.0.0:*
0.0.0.0:*
0.0.0.0:*
0.0.0.0:*
0.0.0.0:*
:::*
:::*
:::*
:::*
LISTEN
LISTEN
LISTEN
LISTEN
LISTEN
LISTEN
LISTEN
LISTEN
LISTEN
LISTEN
LISTEN
27996/python2
22396/python2
30134/python
27194/python2
27194/python2
27194/python2
20752/python2
18439/xinetd
18897/epmd
2909/sshd
4531/master
Validating Non-Root Users for OpenStack Services
To prevent unauthorized access, Cisco NFVI runs OpenStack processes as a non-root user. To verify OpenStack processes are not running as root, use the ps command to get a list of all node processes. In the following example the user is 162:
[root@j11-control-server-1 ~]# ps -aux | grep nova-api
162 27194 0.6
0.0 360924 132996 ?
S Aug08 76:58 /usr/bin/python2
/usr/bin/nova-api
S Aug08 0:01 /usr/bin/python2 162 27231 0.0
0.0 332192 98988 ?
/usr/bin/nova-api
162 27232 0.0
0.0 332192 98988 ?
/usr/bin/nova-api
162 27233 0.0
0.0 332192 98988 ?
/usr/bin/nova-api
S
S
Aug08
Aug08
0:01 /usr/bin/python2
0:01 /usr/bin/python2
Verifying Password Strength
Password strength is critical to Cisco NFVI security. Cisco NFVI passwords can be generated in one of two ways during installation:
• The Cisco NFVI installer generates unique passwords automatically for each protected service.
• You can provide an input file containing the passwords you prefer.
Cisco-generated passwords will be unique, long, and contain a mixture of uppercase, lowercase, and numbers.
If you provide the passwords, password strength will be your responsibility. You can view the passwords by displaying the secrets.yaml file. For example:
[root@mgmt1 ~]# cat ~/openstack-configs/secrets.yaml
ADMIN_USER_PASSWORD: QaZ12n13wvvNY7AH
CINDER_DB_PASSWORD: buJL8pAfytoJ0Icm
CINDER_KEYSTONE_PASSWORD: AYbcB8mx6a5Ot549
CLOUDPULSE_KEYSTONE_PASSWORD: HAT6vbl7Z56yZLtN
COBBLER_PASSWORD: bax8leYFyyDon0ps
CPULSE_DB_PASSWORD: aYGSzURpGChztbMv
DB_ROOT_PASSWORD: bjb3Uvwus6cvaNe5
ELK_PASSWORD: c50e57Dbm7LF0dRV
[ … ]
98
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
Managing Cisco NFVI Security
Reconfiguring Passwords and OpenStack Configurations
Reconfiguring Passwords and OpenStack Configurations
Note This topic does not apply if you installed the optional Cisco Virtual Topology System. For information about use of passwords when VTS is installed, see the Installing Cisco VTS section in the Cisco NFV
Infrastructure 2.2 Installation Guide .
You can reset some configurations after installation including the OpenStack service password and debugs,
TLS certificates, and ELK configurations. Two files, secrets.yaml and openstack_config.yaml, located in :
/root/installer-{tag id}/openstack-configs/, contain the passwords, debugs, TLS file location, and ELK configurations. Also, Elasticsearch uses disk space for the data that is sent to it. These files can grow in size, and Cisco VIM has configuration variables that establishes the frequency and file size under which they will be rotated.
The Cisco VIM installer dynamically generates the OpenStack service and database passwords with 16 alphanumeric characters and stores those in /root/openstack-configs/secrets.yaml. You can change the OpenStack service and database passwords using the password reconfigure command on the deployed cloud. The command identifies the containers affected by the password change and restarts them so the new password can take effect. Always schedule password reconfiguration in a maintenance window because container restarts might disrupt the control plane. You can list the password and configuration that can be changed using following:
[root@mgmt1 ~]# cd ~/installer-xxxx
[root@mgmt1 installer-xxxx]# ciscovim help reconfigure usage: ciscovim reconfigure [--regenerate_secrets] [--setpassword <secretkey>]
[--setopenstackconfig <option>]
Reconfigure the openstack cloud
Optional arguments:
--regenerate_secrets
--setpassword <secretkey>
Regenerate All Secrets
Set of secret keys to be changed.
--setopenstackconfig <option> Set of Openstack config to be changed.
[root@mgmt1 ~]# ciscovim list-openstack-configs
+-------------------------------+----------------------------------------+
| Name | Option |
|
|
|
|
|
+-------------------------------+----------------------------------------+
| CINDER_DEBUG_LOGGING | False |
| KEYSTONE_DEBUG_LOGGING |
| CLOUDPULSE_VERBOSE_LOGGING |
False
True
|
|
MAGNUM_VERBOSE_LOGGING
NOVA_DEBUG_LOGGING
NEUTRON_VERBOSE_LOGGING external_lb_vip_cert
GLANCE_VERBOSE_LOGGING
|
|
|
True
True
True
|
|
|
| /root/openstack-configs/haproxy.pem
|
| True |
|
|
|
|
|
|
|
| elk_rotation_frequency |
| CEILOMETER_VERBOSE_LOGGING |
| elk_rotation_del_older |
| HEAT_DEBUG_LOGGING |
KEYSTONE_VERBOSE_LOGGING | external_lb_vip_cacert
MAGNUM_DEBUG_LOGGING
CINDER_VERBOSE_LOGGING monthly
True
10
False
| /root/openstack-configs/haproxy-ca.crt |
|
| elk_rotation_size |
CLOUDPULSE_DEBUG_LOGGING |
True
True
True
2
False
|
|
|
|
|
|
|
|
|
|
|
|
|
|
NEUTRON_DEBUG_LOGGING
HEAT_VERBOSE_LOGGING
CEILOMETER_DEBUG_LOGGING |
GLANCE_DEBUG_LOGGING
NOVA_VERBOSE_LOGGING
|
|
|
|
True
True
False
False
True
+-------------------------------+----------------------------------------+
[root@mgmt1 installer-xxxx]#
[root@mgmt1 installer-xxxx]# ciscovim list-password-keys
|
|
|
|
|
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
99
Managing Cisco NFVI Security
Reconfiguring Passwords and OpenStack Configurations
+----------------------------------+
| Password Keys |
+----------------------------------+
| COBBLER_PASSWORD |
| CPULSE_DB_PASSWORD |
| DB_ROOT_PASSWORD
| ELK_PASSWORD
| GLANCE_DB_PASSWORD
| GLANCE_KEYSTONE_PASSWORD
| HAPROXY_PASSWORD
| HEAT_DB_PASSWORD
| HEAT_KEYSTONE_PASSWORD
|
|
|
|
|
|
|
| HEAT_STACK_DOMAIN_ADMIN_PASSWORD |
| HORIZON_SECRET_KEY |
| KEYSTONE_ADMIN_TOKEN
| KEYSTONE_DB_PASSWORD
| METADATA_PROXY_SHARED_SECRET
| NEUTRON_DB_PASSWORD
|
|
|
|
| NEUTRON_KEYSTONE_PASSWORD
| NOVA_DB_PASSWORD
| NOVA_KEYSTONE_PASSWORD
| RABBITMQ_ERLANG_COOKIE
| RABBITMQ_PASSWORD
| WSREP_PASSWORD |
+----------------------------------+
[root@mgmt1 installer-xxxx]#
|
|
|
|
|
You can change specific password and configuration identified from the available list. The password and configuration values can be supplied on the command line as follows:
[root@mgmt1 ~]# ciscovim help reconfigure usage: ciscovim reconfigure [--regenerate_secrets] [--setpassword <secretkey>]
[--setopenstackconfig <option>]
Reconfigure the Openstack cloud
Optional arguments:
--regenerate_secrets
--setpassword <secretkey>
Regenerate All Secrets
Set of secret keys to be changed.
--setopenstackconfig <option> Set of Openstack config to be changed.
[root@mgmt1 ~]# ciscovim reconfigure --setpassword ADMIN_USER_PASSWORD,NOVA_DB_PASSWORD
--setopenstackconfig HEAT_DEBUG_LOGGING,HEAT_VERBOSE_LOGGING
Password for ADMIN_USER_PASSWORD:
Password for NOVA_DB_PASSWORD:
Enter T/F for option HEAT_DEBUG_LOGGING:T
Enter T/F for option HEAT_VERBOSE_LOGGING:T
The supplied password must be alphanumeric chars and can be maximum of 32 characters in length. Below are the available configuration parameters for OpenStack:
Configuration Parameter Allowed Values
CEILOMETER_DEBUG_LOGGING T/F (True or False)
CEILOMETER_VERBOSE_LOGGING
CINDER_DEBUG_LOGGING
CINDER_VERBOSE_LOGGING
CLOUDPULSE_DEBUG_LOGGING
CLOUDPULSE_VERBOSE_LOGGING
GLANCE_DEBUG_LOGGING
T/F (True or False)
T/F (True or False)
T/F (True or False)
T/F (True or False)
T/F (True or False)
T/F (True or False)
100
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
Managing Cisco NFVI Security
Reconfiguring Passwords and OpenStack Configurations
GLANCE_VERBOSE_LOGGING
HEAT_DEBUG_LOGGING
HEAT_VERBOSE_LOGGING
KEYSTONE_DEBUG_LOGGING
KEYSTONE_VERBOSE_LOGGING
MAGNUM_DEBUG_LOGGING
MAGNUM_VERBOSE_LOGGING
NEUTRON_DEBUG_LOGGING
NEUTRON_VERBOSE_LOGGING
NOVA_DEBUG_LOGGING
NOVA_VERBOSE_LOGGING elk_rotation_del_older elk_rotation_frequency elk_rotation_size external_lb_vip_cacert external_lb_vip_cert
T/F (True or False)
T/F (True or False)
T/F (True or False)
T/F (True or False)
T/F (True or False)
T/F (True or False)
T/F (True or False)
T/F (True or False)
T/F (True or False)
T/F (True or False)
T/F (True or False)
Days after which older logs will be purged
Available options: "daily", "weekly", "fortnightly",
"monthly"
Gigabytes (entry of type float/int is allowed)
Location of HAProxy CA certificate
Location of HAProxy certificate
Alternatively, you can dynamically regenerate all passwords using regenerate_secrets command option as follows:
[root@mgmt1 ~]# cd ~/installer-xxxx
[root@mgmt1 ~]# ciscovim reconfigure --regenerate_secrets
In addition to the services passwords, you can change the debug and verbose options for Heat, Glance, Cinder,
Nova, Neutron, Keystone and Cloudpulse in /root/openstack-configs/openstack_config.yaml. Other configurations you can modify include ELK configuration parameters, API and Horizon TLS certificates, and
RootCA. , and admin source networks. When reconfiguring these options (for example TLS), always remember that some control plane downtime will occur, so plan the changes during maintenance windows. The command to reconfigure these elements is: ciscovim reconfigure
The command includes a built-in validation to ensure you do not enter typos in the secrets.yaml or openstack_config.yaml files.
When reconfiguration of password or enabling of openstack-services fails, all subsequent pod management operations will be blocked. In this case, it is recommended to contact Cisco TAC to resolve the situation.
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
101
Managing Cisco NFVI Security
Reconfiguring CIMC Password on an Existing Install
Reconfiguring CIMC Password on an Existing Install
Cisco VIM 2.2, allows you to reconfigure the CIMC password on an existing install along with OpenStack services.
Note You must have a C-series pod, up and running with Cisco to reconfigure the CIMC password.
Procedure
Step 1 Update the cimc_password in the CIMC-COMMON section, and/or the individual cimc_password for each server and then run the reconfigure option provided by Ciscovimclient.
CIMC-COMMON: cimc_username: "admin" cimc_password: <"new password">
:
:
SERVERS:
: control-server-2: cimc_info: {'cimc_ip': '<ip_addr>',
'cimc_username': 'admin',
'cimc_password': <'update with new passowrd'>} # only needed if each server has specific password
Step 2 To change the CIMC password for the pod, copy the setupdata into a local dir and update it manually with the CIMC password as shown in the snippet above. The new password must satisfy atleast three of the following conditions:
• Must contain at least one lower case letter.
• Must contain at least one upper case letter.
• Must contain at least one digit between 0 to 9.
• One of these special characters !$#@%^-_+=*&
• Your password has to be 8 to 14 characters long.
Step 3 Run the vim reconfiguration command to post update the setup_data as follows:
[root@mgmt1 ~]# cd /root/
[root@mgmt1 ~]# mkdir MyDir
[root@mgmt1 ~]# cd MyDir
[root@mgmt1 ~]# cp /root/openstack-configs/setup_data.yaml <my_setup_data.yaml>
[root@mgmt1 ~]# cp <my_setup_data.yaml> <my_setup_data_original.yaml>
[root@mgmt1 ~]# vi my_setup_data.yaml (update the relevant CIMC setup_data to include LDAP info)
[root@mgmt1 ~]# cd ~/installer-xxxx
[root@mgmt1 ~]# ciscovim – -setupfile ~/MyDir/<my_setup_data.yaml> reconfigure
Note After successful completion of the CIMC Password, reconfigure operation will trigger an auto-back when the management node auto-back recovery feature is enabled. If the CIMC Password reconfigure fails, contact Cisco TAC to recover from the failure.
102
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
Managing Cisco NFVI Security
Increasing Provider and Tenant VLAN Ranges
Increasing Provider and Tenant VLAN Ranges
Cisco VIM 2.2, provides the flexibility of increasing the provider and tenant VLAN ranges after the post pod installation. Increasing provider and tenant VLAN ranges applies to C-series and B-series pod that is enabled with Cisco UCS Manager plugin. B-series pod running without Cisco UCS Manager plugin, cannot use this feature because of the inherent day-0 networking configuration to be done in FI.
You should have the tenant and provider networks enabled on the pod from day-0.
Procedure
Step 1 Enter the TENANT_VLAN_RANGES and/or PROVIDER_VLAN_RANGES in the setup_data.yaml file and run the reconfigure command through Cisco VIM Client as follows:
TENANT_VLAN_RANGES: old_vlan_info, new_vlan_info or/and
PROVIDER_VLAN_RANGES: old_vlan_info, new_vlan_info
Step 2 Change the pod by copying the setupdata into a local dir and update it manually by running the following command:
[root@mgmt1 ~]# cd /root/ [root@mgmt1 ~]# mkdir MyDir [root@mgmt1 ~]# cd MyDir
Step 3 Update the setup_data, by running the following command:
[root@mgmt1 ~]# cp /root/openstack-configs/setup_data.yaml <my_setup_data.yaml>
[root@mgmt1 ~]# vi my_setup_data.yaml(update the setup_data with the right info)
Step 4 Run the re-configuration command as follows:
[root@mgmt1 ~]# cd ~/installer-xxxx
[root@mgmt1 ~]# ciscovim – -setupfile ~/MyDir/<my_setup_data.yaml> reconfigure
Enabling NFVIMON Post Pod Install
Cisco VIM 2.2 can be optionally installed with a 3 rd party software (aka NFVIMON), that can monitor the health and performance of the NFV infrastructure. The NFVIMON feature enables extensive monitoring and performance data for various components of the cloud infrastructure including Cisco UCS blade and rack servers, service profiles, Nexus top of rack switches, fabric connections and also the OpenStack instances.
The monitoring system is designed such that it can monitor single or multiple Pods from a single management system. NFVIMON can be enabled by extending the setup_data.yaml with relevant information on an existing pod, via the reconfigure option. NFVIMON consists of 4 components: dispatcher, collector, Resource Manager
(RM) and control-center with Cisco Zenpacks (CC). Since NVIFMON is a 3 rd party software, care has been taken to make sure its integration into VIM is loosely coupled and the VIM automation only deals with installing the minimal software piece (dispatcher) needed to monitor the pod. The installing of the other
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
103
Managing Cisco NFVI Security
Before you Begin
NFVIMON components (collector, Resource Manager (RM) and control-center with Cisco Zenpacks (CC)), are Cisco Advance Services led activity and those steps are outside the scope of the current install guide.
Before you Begin
Please ensure that you have engaged with Cisco Advance Services on the planning and installation of the
NFVIMON accessories along with its network requirements. Also, the image information of collector, Resource
Manager (RM) and control-center with Cisco Zenpacks (CC)) is available only through Cisco Advance
Services. At a high level, please have a node designated to host a pair of collector VM for each pod, and a common node to host CC and RM VMs, which can aggregate and display monitoring information from multiple pods. In terms of networking, the collectors VMs need to have 2 interfaces: an interface in br_mgmt of the VIM, and another interface that is routable, which can reach the VIM Installer REST API and the RM
VMs. Since the collector VM is sitting in an independent node, 4 IPs from the management network of the pod should be pre-planned and reserved. Install steps of the collector, Resource Manager (RM) and control-center with Cisco Zenpacks (CC)) are Cisco Advance Services led activity.
Installation of NFVIMON Dispatcher
The dispatcher is the only component in NFVIMON offering that is managed by VIM orchestrator. While the dispatcher acts as a conduit to pass openstack information of the pod to the collectors, it is the Cisco NFVI
Zenpack sitting in the CC/RM node, that gathers the node level information. To enable dispatcher as part of the VIM Install, update the setup_data with the following information:
#Define the PODNAME
PODNAME: <PODNAME with no space>; ensure that this is unique across all the pods
NFVIMON:
MASTER: # Master Section admin_ip: <IP address of Control Centre VM>
COLLECTOR: # Collector Section management_vip: <VIP for ceilometer/dispatcher to use> #Should be unique across the VIM
Pod; Should be part of br_mgmt network
Collector_VM_Info:
hostname: <hostname of Collector VM 1> password: <password_for_collector_vm1> # max length of 32 ccuser_password: <password from master for 'ccuser' (to be used for self monitoring)>
# max length of 32 admin_ip: <ssh_ip_collector_vm1> # Should be part of br_api network management_ip: <mgmt_ip_collector_vm1> # Should be part of br_mgmt network
hostname: <hostname of Collector VM 2> password: <password_for_collector_vm2> # max length of 32 ccuser_password: <password from master for 'ccuser' (to be used for self monitoring)>
# max length of 32 admin_ip: <ssh_ip_collector_vm2> # Should be part of br_api network management_ip: <mgmt_ip_collector_vm2> # Should be part of br_mgmt network
DISPATCHER: rabbitmq_username: admin # Pod specific user for dispatcher module in ceilometer-collector
To monitor TOR, ensure that the following TORSWITCHINFO sections are defined in the setup_data.yaml.
TORSWITHCINFO:
SWITCHDETAILS:
hostname: <switch_a_hostname>: needed username: <TOR switch username> needed password: <TOR switch password> if switch monitoring is needed
# Mandatory for NFVIMON if switch monitoring is
# Mandatory for NFVIMON if switch monitoring is
# Mandatory for NFVBENCH; Mandatory for NFVIMON
104
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
Managing Cisco NFVI Security
Fernet Key Operations needed ssh_ip: <TOR switch ssh ip>
....
hostname: <switch_b_hostname>: needed username: <TOR switch username> needed password: <TOR switch password> needed ssh_ip: <TOR switch ssh ip> needed
....
# Mandatory for NFVIMON if switch monitoring is
# Mandatory for NFVIMON if switch monitoring is
# Mandatory for NFVIMON if switch monitoring is
# Mandatory for NFVIMON if switch monitoring is
# Mandatory for NFVIMON if switch monitoring is
To initiate the integration of NFVIMON on an existing pod, copy the setupdata into a local dir and update it manually with information listed above, then run reconfiguration command as follows:
[root@mgmt1 ~]# cd /root/
[root@mgmt1 ~]# mkdir MyDir
[root@mgmt1 ~]# cd MyDir
[root@mgmt1 ~]# cp /root/openstack-configs/setup_data.yaml <my_setup_data.yaml>
[root@mgmt1 ~]# vi my_setup_data.yaml (update the setup_data to include NFVIMON related info)
[root@mgmt1 ~]# cd ~/installer-xxxx
[root@mgmt1 ~]# ciscovim – -setupfile ~/MyDir/<my_setup_data.yaml> reconfigure
It should be noted that un-configuration of this feature is not supported today. Additionally, NFVIMON is only supported on a pod running Keystone v2.
Fernet Key Operations
Keystone fernet token format is based on the cryptographic authentication method - Fernet. Fernet is an implementation of Symmetric Key Encryption. Symmetric key encryption is a cryptographic mechanism that uses the same cryptographic key to encrypt plaintext and the same cryptographic key to decrypt ciphertext.
Fernet authentication method also supports multiple keys where it takes a list of symmetric keys, performs all encryption using the first key in a list and attempts to decrypt using all the keys from that list.
The Cisco NFVI pods uses Fernet keys by default. The following operations can be carried out in Cisco NFVI pods.
To check if the fernet keys are successfully synchronized across the keystone nodes.
[root@mgmt1 ~]# cd ~/installer-xxxx
[root@mgmt1 ~]# ciscovim help check-fernet-keys usage: ciscovim check-fernet-keys
Check whether the fernet keys are successfully synchronized across keystone nodes.
To set the fernet key frequency:
[root@mgmt1 ~]# cd ~/installer-xxxx
[root@mgmt1 ~]# ciscovim help period-rotate-fernet-keys usage: ciscovim period-rotate-fernet-keys <SET_PERIOD_ROTATION_FERNET_KEYS>
Set the frequency of fernet keys rotation on keystone
Positional arguments:
<SET_PERIOD_ROTATION_FERNET_KEYS>
Frequency to set for period rotation
To forcefully rotate the fernet keys:
[root@mgmt1 ~]# cd ~/installer-xxxx
[root@mgmt1 ~]# ciscovim help rotate-fernet-keys usage: ciscovim rotate-fernet-keys
Trigger rotation of the fernet keys on keystone
To resync the fernet keys across the keystone nodes:
[root@mgmt1 ~]# cd ~/installer-xxxx
[root@mgmt1 ~]# ciscovim help resync-fernet-keys usage: ciscovim resync-fernet-keys
Resynchronize the fernet keys across all the keystone nodes
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
105
Managing Cisco NFVI Security
Managing Certificates
Managing Certificates
When TLS protection is configured for the OpenStack APIs, the two certificate files, haproxy.pem and haproxy-ca.crt, are stored in the /root/openstack-configs/ directory. Clients running on servers outside of the deployed cloud to verify cloud authenticity need a copy of the root certificate (haproxy-ca.crt). If a well-known certificate authority has signed the installed certificate, no additional configuration is needed on client servers.
However, if a self-signed or local CA is used, copy haproxy-ca.crt to each client. Following instructions specific to the client operating system or browser to install the certificate as a trusted certificate.
Alternatively, you can explicitly reference the certificate when using the OpenStack CLI by using the environment variable OS_CACERT or command line parameter – cacert.
While Cisco NFVI is operational, a daily check is made to monitor the expiration dates of the installed certificates. If certificates are not nearing expiration, an informational message is logged. As the certificate approaches expiration, an appropriate warning or critical message is logged.
2017-04-24T13:56:01 INFO Certificate for OpenStack Endpoints at 192.168.0.2:5000 expires in 500 days
It is important to replace the certificates before they expire. After Cisco NFVI is installed, you can update the certificates by replacing the haproxy.pem and haproxy-ca.crt files and running the reconfigure command: cd ~/installer-xxxx; ciscovim reconfigure
Enabling TLS post install
Enabling TLS is important to ensure the Cisco VIM network is secure. TLS encrypts and authenticates communication to the cloud endpoints. When TLS is enabled, two additional information has to be provided to the installer: haproxy.pem and haproxy-ca-crt. These must be placed in the ~/installer-xxxx/openstack-configs directory.
Procedure
Step 1 Along with updating the ~/installer-xxxx/openstack-configs with the right certificates, take a backup of the setupdata file and update the file manually with the configs listed as, external_lb_vip_tls: True # if using VIP IP for TLS or external_lb_vip_fqdn: host or DNS name matching external_lb_vip_address (if FQDN is needed)
Step 2 Run the reconfigure command as follows:
[root@mgmt1 ~]# cd /root/ [root@mgmt1 ~]# mkdir MyDir
[root@mgmt1 ~]# cp /root/openstack-configs/setup_data.yaml /root/MyDir/
Step 3 Update the setup_data to include TLS option and copy the certificates to ~/installer-xxxx/openstack-configs directory.
[root@mgmt1 ~]# cd /root/MyDir/
[root@mgmt1 ~]# vi setup_data.yaml [root@mgmt1 ~]# cd ~/installer-xxxx
[root@mgmt1 ~]# ciscovim --setupfile /root/MyDir/setup_data.yaml reconfigure
106
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
Managing Cisco NFVI Security
Reconfiguring TLS Certificates
Reconfiguring TLS Certificates
Cisco VIM provides a way to configure TLS certificates on-demand for any reason. For Example: certificate expiration policies governing certificate management.
Reconfiguration of certificates in general is supported in the following components:
• Cisco VIM Rest API endpoints:
Steps to be performed to reconfigure certificate files are as follows:
◦ Copy the new key, CA root and certificate files into the ~/openstack-configs folder under the following filenames cp <new-ca-root-cert> ~/openstack-configs/mercury-ca.crt
cp <new-key-file> ~/openstack-configs/mercury.key
cp <new-cert-file> ~/openstack-configs/mercury.crt
◦ Once copied run the reconfigure steps as under: cd ~/installer-xxxx/tools
./restapi.py -a reconfigure-tls
• OpenStack API endpoints
Steps to be performed to reconfigure certificate files are as follows:
◦ Copy the new key, CA root and certificate files into the ~/openstack-configs folder under the following filenames cp <new-ca-root-cert> ~/openstack-configs/haproxy-ca.crt
cp <new-cert-file> ~/openstack-configs/haproxy.pem
◦ Once copied run the reconfigure steps as follows: cd ~/installer-xxxx; ciscovim reconfigure
• SwiftStack Service through Horizon and CinderBackup Service.
◦ Reconfiguring TLS certificates for SwiftStack mainly involves client side certificate updates. The
CA root certificate in both these cases is updated for components within OpenStack that are clients of the SwiftStack service in general.
◦ Copy the new CA root certificate to the ~/openstack-configs folder and run reconfigure.
cp <new-ca-root-cert> ~/openstack-configs/haproxy-ca.crt
cd ~/installer-xxxx; ciscovim reconfigure
• Logstash service and Fluentd (client-side certificates).
◦ For the Logstash service on the management node, both the key and certificate file will be reconfigured as part of the reconfigure operation.
◦ For the Fluentd service on the controllers, compute and storage nodes, the certificate file will be reconfigured as part of the reconfigure operation.
◦ Copy of the key and certificate files to the ~/openstack-configs folder on the management node and run reconfigure operation.
cp <new-key-file> ~/openstack-configs/logstash-forwarder.key
cp <new-cert-file> ~/openstack-configs/logstash-forwarder.crt
cd ~/installer-xxxx; ciscovim reconfigure
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
107
Managing Cisco NFVI Security
Enabling Keystone v3 on an Existing Install
Enabling Keystone v3 on an Existing Install
To continue enhancing our security portfolio, and multi-tenancy with the use of domains, Keystone v3 support has been added in Cisco VIM 2.2 from an authentication end-point. It should be noted that Keystone v2 and v3 are mutually exclusive. The administrator has to decide during install time the authentication end-point version to go with. By default, VIM orchestrator picks keystone v2 as the authentication end-point. So one can enable Keystonev3 as an install option on day-0 (see 2.2 CiscoVIM install guide), or enable it as a reconfigure option after the pod is installed. To enable Keystone v3 after the pod is installed, one needs to define the following under the optional service section in the setup_data.yam filel.
# Optional Services:
OPTIONAL_SERVICE_LIST:
- keystonev3
To initiate the integration of Keystone v3 on an existing pod, copy the setupdata into a local dir and update it manually, then run reconfiguration command as follows:
[root@mgmt1 ~]# cd /root/
[root@mgmt1 ~]# mkdir MyDir
[root@mgmt1 ~]# cd MyDir
[root@mgmt1 ~]# cp /root/openstack-configs/setup_data.yaml <my_setup_data.yaml>
[root@mgmt1 ~]# vi my_setup_data.yaml (update the setup_data to include keystone v3 info)
[root@mgmt1 ~]# cd ~/installer-xxxx
[root@mgmt1 ~]# ciscovim – -setupfile ~/MyDir/<my_setup_data.yaml> reconfigure
It should be noted that un-configuration of this feature is not supported today. Additionally, re-versioning
Keystone API from v3 to v2 is also not supported.
LDAP/AD support with Keystone v3
With the introduction of KeystoneV3, the openstack service authentication can now we delegated to an external
LDAP/AD server. In Cisco VIM 2.2, this feature has been introduced optionally if the authorization is done by Keystone v3. Just like Keystonev3, this feature can be enabled on an existing pod running Cisco VIM 2.2.
To avail of this feature post pod deployment, the setup_data needs to be augmented with the following information during the installation of the pod.
An important pre-requisite for enabling AD/LDAP integration is that the AD/LDAP endpoint MUST be reachable from all the Controller nodes that run OpenStack Keystone Identity Service.
LDAP: domain: <Domain specific name> user_objectclass: <objectClass for Users> # e.g organizationalPerson group_objectclass: <objectClass for Groups> # e.g. groupOfNames user_tree_dn: '<DN tree for Users>' # e.g. 'ou=Users,dc=cisco,dc=com' group_tree_dn: '<DN tree for Groups>' # e.g. 'ou=Groups,dc=cisco,dc=com' suffix: '<suffix for DN>' # e.g. 'dc=cisco,dc=com' url: '<ldap:// host:port>' # e.g. 'ldap://172.26.233.104:389' or url: '<ldaps|ldap>://[<ip6-address>]:[port]' e.g.ldap://[2001:420:293:2487:d1ca:67dc:94b1:7e6c]:389 ---> note the mandatory "[.. ]" around the ipv6 address user: '<DN of bind user>' # e.g. 'dc=admin,dc=cisco,dc=com' password: <password> # e.g. password of bind user user_filter = (memberOf=CN=os-users,OU=OS-Groups,DC=mercury,DC=local) user_id_attribute = sAMAccountName user_name_attribute = sAMAccountName user_mail_attribute = mail # Optional group_tree_dn = ou=OS-Groups,dc=mercury,dc=local group_name_attribute = sAMAccountName
108
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
Managing Cisco NFVI Security
Enabling ACI in Cisco VIM
To initiate the integration of LDAP with Keystone v3 on an existing pod, copy the setupdata into a local dir and update it manually with the relevant LDAP and Keystone v3 (if absent from before) configuration, then run reconfiguration command as follows:
[root@mgmt1 ~]# cd /root/
[root@mgmt1 ~]# mkdir MyDir
[root@mgmt1 ~]# cd MyDir
[root@mgmt1 ~]# cp /root/openstack-configs/setup_data.yaml <my_setup_data.yaml>
[root@mgmt1 ~]# vi my_setup_data.yaml (update the setup_data to include LDAP info)
[root@mgmt1 ~]# cd ~/installer-xxxx
[root@mgmt1 ~]# ciscovim – -setupfile ~/MyDir/<my_setup_data.yaml> reconfigure
The reconfigure feature supports a full or partial reconfiguration of the LDAP integration service.
Note All the parameters within the LDAP stanza are configurable with the exception of the domain parameter.
Integrating identity with LDAP over TLS : The automation supports keystone integration with LDAP over
TLS. In order to enable TLS, the CA root certificate must be presented as part of the
/root/openstack-configs/haproxy-ca.crt file. The url parameter within the LDAP stanza must be set to ldaps.
Additionally, the url parameter supportsthe following format: url: '<ldaps | ldap>://<FQDN | IP-Address>:[port]'
The protocol can be one of the following: ldap for non-ssland ldaps when TLS has to be enabled.
The ldap host can be a fully-qualified domainname (FQDN) or an IPv4 or v6 Address depending on how the
SSL certificates are generated. .
The port number is optional and if not provided assumes that the ldap services are running on the default ports. For Example:. 389 for non-ssl and 636 for ssl. However, if these are not the defaults, then the non-standard port numbers must be provided. Except for the domain, all other item values can be changed via the 'reconfigure' option.
Enabling ACI in Cisco VIM
In Cisco VIM 2.2, we have integrated the Opflex ML2 plugin (in Unified mode) to manage the tenant VLANs dynamically, as VMs come and go in the cloud. In addition, we support an administrator driven automated workflow to provison the provider networks. In VIM 2.2, this is supported on a C-series based Fullon or micropod running with Cisco VIC 1227. While the integration of ACI into CVIM is a day-0 activity, VIM supports the replacement of the ACI controller in the ACI cluster, and the expansion of the leaf switches to increase the fabric.
Procedure
Step 1 To update the setup_data with one or both follow the below steps:
APICINFO: apic_hosts: '<ip1|host1>:[port], <ip2|host2>:[port], <ip3|host3>:[port]'
# max of 3, min of 1, not 2; reconfigurable
Since the APIC manages the Leaf switches, its mandatory to define the new Leaf switches (in pairs) in the following format:
TORSWITCHINFO: (mandatory)
:
SWITCHDETAILS:
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
109
Managing Cisco NFVI Security
Enabling ACI in Cisco VIM
:
hostname: <leaf-hostname-1> vpc_peer_keepalive: <leaf-hostname-2> vpc_domain: 1 # Must be unique across pairs br_mgmt_port_info: 'eth1/27' # br_mgmt_* attributes must exist on at least one pair br_mgmt_vlan_info: '3401' node_id: <int> # unique across switches
hostname: <leaf-hostname-2> vpc_peer_keepalive: <leaf-hostname-1> vpc_domain: 1 br_mgmt_port_info: 'eth1/27' # br_mgmt_* attributes must exist on at least one pair br_mgmt_vlan_info: '3401' node_id: <int> # unique across switches
Step 2 T o initiate the change in ACI config on an existing pod, copy the setupdata into a local dir and update it manually with the relevantapic_hosts and/or new TORSWITCH information, then run reconfiguration commands follows:
[root@mgmt1 ~]# cd /root/ [root@mgmt1 ~]# mkdir MyDir [root@mgmt1 ~]# cd MyDir
[root@mgmt1 ~]# cp /root/openstack-configs/setup_data.yaml <my_setup_data.yaml> [root@mgmt1
~]# vi my_setup_data.yaml (update the setup_data to include ACI info)
[root@mgmt1 ~]# cd ~/installer-xxxx
[root@mgmt1 ~]# ciscovim – -setupfile ~/MyDir/<my_setup_data.yaml> reconfigure
110
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
C H A P T E R
5
Managing Cisco NFVI Storage
This chapter describes basic architectural concepts that will help you understand the Cisco NFVI data storage architecture and data flow. It also provides techniques you can use to monitor the storage cluster health and the health of all systems that depend on it
•
Cisco NFVI Storage Architecture, page 111
•
Verifying and Displaying Ceph Storage Pools, page 112
•
Checking the Storage Cluster Health, page 113
•
Checking Glance Connectivity, page 114
•
Verifying Glance and Ceph Monitor Keyrings, page 115
•
Verifying Glance Image ID on Ceph, page 116
•
Checking Cinder Connectivity, page 116
•
Verifying the Cinder and Ceph Monitor Keyrings, page 117
•
Verifying the Cinder Volume ID on Ceph, page 118
•
Checking Nova Connectivity, page 118
•
Verifying the Nova and Ceph Monitor Keyrings, page 119
•
Verifying Nova Instance ID, page 120
•
Displaying Docker Disk Space Usage, page 121
•
Reconfiguring SwiftStack Integration, page 121
•
Reconfiguring Administrator Source Networks, page 123
•
Password Reset for Cisco VIM Management Node, page 123
Cisco NFVI Storage Architecture
OpenStack has multiple storage back ends. Cisco NFVI uses the Ceph back end. Ceph supports both block and object storage and is therefore used to store VM images and volumes that can be attached to VMs. Multiple
OpenStack services that depend on the storage backend include:
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
111
Managing Cisco NFVI Storage
Verifying and Displaying Ceph Storage Pools
• Glance (OpenStack image service) — Uses Ceph to store images.
• Cinder (OpenStack storage service) — Uses Ceph to create volumes that can be attached to VMs.
• Nova (OpenStack compute service) — Uses Ceph to connect to the volumes created by Cinder.
The following figure shows the Cisco NFVI storage architecture component model.
Figure 18: Cisco NFVI Storage Architecture
Verifying and Displaying Ceph Storage Pools
Ceph is configured with four independent pools: images, volumes, vms, and backups. (A default rbd pool is used internally.) Each Ceph pool is mapped to an OpenStack service. The Glance service stores data in the images pool, and the Cinder service stores data in the volumes pool. The Nova service can use the vms pool to boot ephemeral disks directly from the Ceph cluster depending on how the NOVA_BOOT_FROM option in the ~/openstack-configs/setup_data.yaml was configured prior to Cisco NFVI installation. If
NOVA_BOOT_FROM is set to ceph before you run the Cisco NFVI installation, the Nova service will boot from the Ceph vms pool. By default, NOVA_BOOT_FROM is set to local, which means that all VM ephemeral disks are stored as files in the compute nodes. Changing this option after installation does not affect the use of the vms pool for ephemeral disks.
The Glance, Cinder, and Nova OpenStack services depend on the Ceph cluster for backend storage. Therefore, they need IP connectivity to the controller nodes. The default port used to connect Glance, Cinder, and Nova to the Ceph cluster is 6789. Authentication through cephx is required, which means authentication tokens, called keyrings, must be deployed to the OpenStack components for authentication.
To verify and display the Cisco NFVI Ceph storage pools:
112
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
Managing Cisco NFVI Storage
Checking the Storage Cluster Health
Procedure
Step 1 Launch a SSH session to a controller node, for example:
[root@management-server-cisco ~]# ssh root@controller_server-1
Step 2 Navigate to the Ceph Monitor container:
[root@controller_server-1 ~]# cephmon
Step 3 List the Ceph pools: cephmon_4612 [root@controller_server-1 ~]# ceph osd lspools
0 rbd,1 images,2 volumes,3 vms,4 backups,
Step 4 List the images pool content: cephmon_4612 [ceph@controller_server-1 /]$ rbd list images a4963d51-d3b7-4b17-bf1e-2ebac07e1593
Checking the Storage Cluster Health
Cisco recommends that you perform a few verifications to determine whether the Ceph cluster is healthy and is connected to the Glance, Cinder, and Nova OpenStack services, which have Ceph cluster dependencies.
The first task to check the health of the cluster itself by completing the following steps:
Procedure
Step 1 From the Cisco NFVI management node, launch a SSH session to a controller node, for example:
[root@management-server-cisco ~]# ssh root@controller_server-1
Step 2 Navigate to the Ceph Monitor container:
[root@controller_server-1 ~]# cephmon
Step 3 Check the Ceph cluster status: cephmon_4612 [ceph@controller_server-1 ceph]$ ceph status
Sample response: cluster dbc29438-d3e0-4e0c-852b-170aaf4bd935 health HEALTH_OK monmap e1: 3 mons at {ceph-controller_server-1=20.0.0.7:6789/0, ceph-controller_server-2=20.0.0.6:6789/0,ceph-controller_server-3=20.0.0.5:6789/0} election epoch 8, quorum 0,1,2 ceph-controller_server-3, ceph-controller_server-2,ceph-controller_server-1 osdmap e252: 25 osds: 25 up, 25 in pgmap v593: 1024 pgs, 5 pools, 406 MB data, 57 objects
2341 MB used, 61525 GB / 61527 GB avail
1024 active+clean
This example displays three monitors, all in good health, and 25 object storage devices (OSDs). All OSDs show as up and in the cluster.
Step 4 To see a full listing of all OSDs sorted by storage node, enter: cephmon_4612 [ceph@controller_server-1 ceph]$ ceph osd tree
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
113
Managing Cisco NFVI Storage
Checking Glance Connectivity
Sample response:
ID WEIGHT TYPE NAME
-1 60.18979 root default
-2 18.96994
1 2.70999
5 2.70999
6 2.70999
osd.5
osd.6
UP/DOWN REWEIGHT PRIMARY-AFFINITY host controller_server-2 osd.1
up 1.00000
up 1.00000
1.00000
1.00000
11
12
2.70999
2.70999
osd.11
osd.12
up 1.00000
up 1.00000
up 1.00000
1.00000
1.00000
1.00000
17
20
2.70999
2.70999
-3 18.96994
0 2.70999
osd.17
osd.20
host controller_server-1 osd.0
up 1.00000
up 1.00000
1.00000
1.00000
4
8
10
13
16
18
2.70999
2.70999
2.70999
2.70999
2.70999
2.70999
-4 18.96994
2 2.70999
3
7
2.70999
2.70999
9 2.70999
14 2.70999
15 2.70999
19 2.70999
-5 3.27997
21 0.81999
22 0.81999
23 0.81999
24 0.81999
osd.4
osd.8
osd.10
osd.13
osd.16
osd.18
host controller_server-3 osd.2
osd.3
osd.7
osd.9
osd.14
osd.15
osd.21
osd.22
osd.23
osd.24
up 1.00000
up 1.00000
up 1.00000
up 1.00000
up 1.00000
up up up up up up up up up
1.00000
1.00000
up 1.00000
1.00000
up 1.00000
1.00000
1.00000
osd.19
host controller_server-4 up 1.00000
up 1.00000
1.00000
1.00000
1.00000
1.00000
1.00000
1.00000
1.00000
1.00000
1.00000
1.00000
1.00000
1.00000
1.00000
1.00000
1.00000
1.00000
1.00000
1.00000
1.00000
1.00000
1.00000
1.00000
What to Do Next
After you verify the Ceph cluster is in good health, check that the individual OpenStack components have connectivity and their authentication tokens — keyrings — match the Ceph Monitor keyrings. The following procedures show how to check the connectivity and authentication between Ceph and Glance, Ceph and
Cinder, and Ceph and Nova.
Checking Glance Connectivity
The Glance API container must be connected to the Cisco NFVI controller nodes. Complete the following steps to verify the Glance to controller node connectivity:
Procedure
Step 1 From the management node, launch a SSH session to a controller node, for example:
[root@management-server-cisco ~]# ssh root@controller_server-1
114
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
Managing Cisco NFVI Storage
Verifying Glance and Ceph Monitor Keyrings
Step 2 Navigate to the Glance API container:
[root@controller_server-1 ~]# glanceapi
Step 3 Check the Glance API container connectivity to a controller node different from the one entered in Step 1, in this case, controller_server 2: glanceapi_4612 [glance@controller_server-1 /]$ curl controller_server-2:6789
If the connection is successful, you will see a message like the following: glanceapi_4612 [glance@controller_server-1 /]$ curl controller_server-2:6789 ceph v027?
If the connection is not successful, you will see a message like the following: glanceapi_4612 [glance@controller_server-1 /]$ curl controller_server-2:6789 curl: (7) Failed connect to controller_server-2:6789; Connection refused
A message like the one above means the Ceph monitor running on the target controller node controller_server-2 is not listening on the specified port or there is no route to it from the Glance API container.
Checking one controller node should be enough to ensure one connection path available for the Glance API.
However, because Cisco NFVI controller nodes run as part of an HA cluster, you should run Step 3 above targeting all the controller nodes in the Cisco NFVI pod.
What to Do Next
After you verify the Glance API connectivity to all Cisco NFVI controller nodes, check the Glance keyring to ensure it matches the Ceph monitor keyring.
Verifying Glance and Ceph Monitor Keyrings
Complete the following steps to verify the Glance API keyring matches the Ceph Monitor keyring.
Procedure
Step 1 Launch a SSH session to a controller node, for example:
[root@management-server-cisco ~]# ssh root@controller_server-1
Step 2 Navigate to the Glance API container:
[root@controller_server-1 ~]# glanceapi
Step 3 Check the Glance keyring content, for example: glanceapi_4612 [glance@controller_server-1 /]$ cat /etc/ceph/client.glance.keyring
[client.glance] key = AQA/pY1XBAnHMBAAeS+0Wmh9PLZe1XqkIW/p0A==
Step 4 Navigate to the Ceph Monitor container:
[root@controller_server-1 ~]# cephmon
Step 5 Display the Ceph Monitor keyring content: cephmon_4612 [ceph@controller_server-1 ceph]$ cat /etc/ceph/ceph.client.glance.keyring
[client.glance] key = AQA/pY1XBAnHMBAAeS+0Wmh9PLZe1XqkIW/p0A==
Verify the keyring matches the Glance API keyring displayed in Step 3.
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
115
Managing Cisco NFVI Storage
Verifying Glance Image ID on Ceph
What to Do Next
A final check to ensure that Ceph and Glance are connected is to actually import a Glance image using Horizon or the Glance CLI. After you import an image, compare the IDs seen by Glance and by Ceph. They should match, indicating Ceph is handling the backend for Glance.
Verifying Glance Image ID on Ceph
The following steps verify Ceph is properly handling new Glance images by checking that the image ID for a new Glance image is the same as the image ID displayed in Ceph.
Procedure
Step 1 From the management node, load the OpenStack authentication variables:
[root@management-server-cisco ~]# source ~/openstack-configs/openrc
Step 2 Import any Glance image. In the example below, a RHEL 7.1 qcow2 image is used.
[root@management-server-cisco images]# glance image-create
--name "rhel" --disk-format qcow2 --container-format bare --file rhel-guest-image-7.1-20150224.0.x86_64.qcow2
Step 3 List the Glance images:
[root@management-server-cisco images]# glance image-list | grep rhel
| a4963d51-d3b7-4b17-bf1e-2ebac07e1593 | rhel
Step 4 Navigate to the Ceph Monitor container:
[root@controller_server-1 ~]# cephmon
Step 5 Display the contents of the Ceph images pool: cephmon_4612 [ceph@controller_server-1 ceph]$ rbd list images | grep a4963d51-d3b7-4b17-bf1e-2ebac07e1593 a4963d51-d3b7-4b17-bf1e-2ebac07e1593
Step 6 Verify that the Glance image ID displayed in Step 3 matches the image ID displayed by Ceph.
Checking Cinder Connectivity
The Cinder volume container must have connectivity to the Cisco NFVI controller nodes. Complete the following steps to verify Cinder volume has connectivity to the controller nodes:
Procedure
Step 1 From the management node, launch a SSH session to a controller node, for example:
[root@management-server-cisco ~]# ssh root@controller_server-1
Step 2 Navigate to the Cinder volume container:
[root@controller_server-1 ~]# cindervolume
116
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
Managing Cisco NFVI Storage
Verifying the Cinder and Ceph Monitor Keyrings
Step 3 Check the Cinder volume container connectivity to a controller node different from the one entered in Step
1, in this case, controller_server-2: cindervolume_4612 [cinder@controller_server-1 /]$ curl controller_server-2:6789
If the connection is successful, you will see a message like the following: cindervolume_4612 [cinder@controller_server-1 /]$ curl controller_server-2:6789 ceph v027?
If the connection is not successful, you will see a message like the following: cindervolume_4612 [cinder@controller_server-1 /]$ curl controller_server-2:6789 curl: (7) Failed connect to controller_server-2:6789; Connection refused
A message like the one above means the Ceph monitor running on the target controller node controller_server-2 is not listening on the specified port or there is no route to it from the Cinder volume container.
Checking one controller node should be enough to ensure one connection path is available for the Cinder volume. However, because Cisco NFVI controller nodes run as part of an HA cluster, repeat Step 3 targeting all the controller nodes in the Cisco NFVI pod.
What to Do Next
After you verify the Cinder volume connectivity to all Cisco NFVI controller nodes, check the Cinder keyring to ensure it matches the Ceph monitor keyring.
Verifying the Cinder and Ceph Monitor Keyrings
Complete the following steps to verify the Cinder volume keyring matches the Ceph Monitor keyring.
Procedure
Step 1 From the management node, launch a SSH session to a controller node, for example:
[root@management-server-cisco ~]# ssh root@controller_server-1
Step 2 Navigate to the Cinder volume container:
[root@controller_server-1 ~]# cindervolume
Step 3 Check the Cinder keyring content, for example: cindervolume_4612 [cinder@controller_server-1 /]$ cat /etc/ceph/client.cinder.keyring
[client.cinder] key = AQA/pY1XBAnHMBAAeS+0Wmh9PLZe1XqkIW/p0A==
Step 4 Navigate to the Ceph Monitor container:
[root@controller_server-1 ~]# cephmon
Step 5 Display the Ceph Monitor keyring content: cephmon_4612 [ceph@controller_server-1 ceph]$ cat /etc/ceph/ceph.client.cinder.keyring
[client.cinder] key = AQA/pY1XBAnHMBAAeS+0Wmh9PLZe1XqkIW/p0A==
Verify the keyring matches the Cinder volume keyring displayed in Step 3.
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
117
Managing Cisco NFVI Storage
Verifying the Cinder Volume ID on Ceph
What to Do Next
As a final Ceph and Cinder connectivity verification, import a Cinder image using Horizon or the Cinder CLI.
After you import the image, compare the IDs seen by Cinder and by Ceph. They should match, indicating
Ceph is handling the backend for Cinder.
Verifying the Cinder Volume ID on Ceph
The following steps verify Ceph is properly handling new Cinder volumes by checking that the volume ID for a new Cinder volume is the same as the volume ID displayed in Ceph.
Procedure
Step 1 From the management node, load the OpenStack authentication variables:
[root@management-server-cisco ~]# source ~/openstack-configs/openrc
Step 2 Create an empty volume:
[root@management-server-cisco ~]# cinder create --name ciscovol1 5
The above command will create a new 5 GB Cinder volume named ciscovol1.
Step 3 List the Cinder volumes:
[[root@management-server-cisco ~]# cinder list
+--------------------------------------+--------+------------------+--
| ID | Status | Migration Status | …
| … | dd188a5d-f822-4769-8a57-c16694841a23 | in-use |
+----------------------------------+------+
Step 4 Navigate to the Ceph Monitor container:
[root@controller_server-1 ~]# cephmon
-
Step 5 Display the contents of the Ceph volumes pool: cephmon_4612 [ceph@controller_server-1 ceph]$ rbd list volumes volume-dd188a5d-f822-4769-8a57-c16694841a23
Step 6 Verify that the Cinder volume ID displayed in Step 3 matches the volume ID displayed by Ceph, excluding the "volume-" prefix.
Checking Nova Connectivity
The Nova libvirt container must have connectivity to the Cisco NFVI controller nodes. Complete the following steps to verify Nova has connectivity to the controller nodes:
Procedure
Step 1 From the management node, launch a SSH session to a controller node, for example:
[root@management-server-cisco ~]# ssh root@Computenode_server-1
118
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
Managing Cisco NFVI Storage
Verifying the Nova and Ceph Monitor Keyrings
Step 2 Navigate to the Nova libvirt container:
[root@compute_server-1 ~]# libvirt
Step 3 Check the Nova libvirt container connectivity to a controller node, in this case, controller_server 1: novalibvirt_4612 [root@compute_server-1 /]$ curl controller_server-2:6789
If the connection is successful, you will see a message like the following: novalibvirt_4612 [root@compute_server-1 /]$ curl controller_server-1:6789 ceph v027?
If the connection is not successful, you will see a message like the following: novalibvirt_4612 [root@compute_server-1 /]$ curl controller_server-1:6789 curl: (7) Failed connect to controller_server-1:6789; Connection refused
A message like the one above means the Ceph monitor running on the target controller node controller_server-1 is not listening on the specified port or there is no route to it from the Nova libvirt container.
Checking one controller node should be enough to ensure one connection path available for the Nova libvirt.
However, because Cisco NFVI controller nodes run as part of an HA cluster, you should run Step 3 above targeting all the controller nodes in the Cisco NFVI pod.
What to Do Next
After you verify the Nova libvirt connectivity to all Cisco NFVI controller nodes, check the Nova keyring to ensure it matches the Ceph monitor keyring.
Verifying the Nova and Ceph Monitor Keyrings
Complete the following steps to verify the Nova libvert keyring matches the Ceph Monitor keyring.
Procedure
Step 1 From the management node, launch a SSH session to a controller node, for example:
[root@management-server-cisco ~]# ssh root@controller_server-1
Step 2 Navigate to the Nova libvert container:
[root@compute_server-1 ~]# libvirt
Step 3 Extract the libvirt secret that contains the Nova libvirt keyring: novalibvirt_4612 [root@compute_server-1 /]# virsh secret-list
UUID Usage …
----------------------------------------------------------------b5769938-e09f-47cb-bdb6-25b15b557e84 ceph client.cinder
…
Step 4 Get the keyring from the libvert secret: novalibvirt_4612 [root@controller_server-1 /]# virsh secret-get-value b5769938-e09f-47cb-bdb6-25b15b557e84
AQBApY1XQCBBEBAAroXvmiwmlSMEyEoXKl/sQA==
Step 5 Navigate to the Ceph Monitor container:
[root@controller_server-1 ~]# cephmon
Step 6 Display the Ceph Monitor keyring content: cephmon_4612 [ceph@controller_server-1 ceph]$ cat /etc/ceph/ceph.client.cinder.keyring
[client.cinder]
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
119
Managing Cisco NFVI Storage
Verifying Nova Instance ID key = AQBApY1XQCBBEBAAroXvmiwmlSMEyEoXKl/sQA==
Verify the keyring matches the Nova libvert keyring displayed in Step 3. Notice that in the above example the Cinder keyring is checked even though this procedure is for the Nova libvert keyring. This occurs because the Nova services need access to the Cinder volumes and so authentication to Ceph uses the Cinder keyring.
What to Do Next
Complete a final check to ensure that Ceph and Nova are connected by attaching a Nova volume using Horizon or the Nova CLI. After you attach the Nova volume, check the libvert domain.
Verifying Nova Instance ID
From the management node, complete the following steps to verify the Nova instance ID:
Procedure
Step 1 Load the OpenStack authentication variables:
[root@management-server-cisco installer]# source ~/openstack-configs/openrc
Step 2 List the Nova instances:
[root@management-server-cisco images]# nova list
+--------------------------------------+------------+--------+--------
| ID | Name | Status | Task
+--------------------------------------+------------+--------+--------
| 77ea3918-793b-4fa7-9961-10fbdc15c6e5 | cisco-vm | ACTIVE | -
+----------------------------------+-----------+-------+-
Step 3 Show the Nova instance ID for one of the instances:
[root@management-server-cisco images]# nova show
77ea3918-793b-4fa7-9961-10fbdc15c6e5 | grep instance_name
| OS-EXT-SRV-ATTR:instance_name | instance-00000003
The Nova instance ID in this example is instance-00000003. This ID will be used later with the virsh command.
Nova instance IDs are actually the libvirt IDs of the libvirt domain associated with the Nova instance.
Step 4 Identify the compute node where the VM was deployed:
[root@management-server-cisco images] # nova show 77ea3918-793b-4fa7-9961-10fbdc15c6e5 | grep hypervisor
| OS-EXT-SRV-ATTR:hypervisor_hostname | compute_server-1
The compute node in this case is compute_server-1. You will connect to this compute node to call the virsh commands. Next, you get the volume ID from the libvirt domain in the Nova libvirt container.
Step 5 Launch a SSH session to the identified compute node, compute_server-1:
[root@management-server-cisco ~]# ssh root@compute_server-1
Step 6 Navigate to the Nova libvirt container:
[root@compute_server-1 ~]# libvirt
Step 7 Get the instance libvirt domain volume ID: novalibvirt_4612 [root@compute_server-1 /] # virsh dumpxml instance-00000003 | grep rbd
<source protocol='rbd' name='volumes/volume-dd188a5d-f822-4769-8a57-c16694841a23'>
120
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
Managing Cisco NFVI Storage
Displaying Docker Disk Space Usage
Step 8 Launch a SSH session to a controller node:
[root@management-server-cisco ~]# ssh root@controller_server-1
Step 9 Navigate to the Ceph Monitor container:
[root@compute_server-1 ~]# cephmon
Step 10 Verify volume ID matches the ID in Step 7: cephmon_4612 [ceph@controller_server-1 ceph]
$ rbd list volumes | grep volume-dd188a5d-f822-4769-8a57-c16694841a23 volume-dd188a5d-f822-4769-8a57-c16694841a23
Displaying Docker Disk Space Usage
Docker supports multiple storage back ends such as Device Mapper, thin pool, overlay, and AUFS. Cisco
VIM uses the devicemapper storage driver because it provides strong performance and thin provisioning.
Device Mapper is a kernel-based framework that supports advanced volume management capability. Complete the following steps to display the disk space used by Docker containers.
Procedure
Step 1 Launch a SSH session to a controller or compute node, for example:
[root@management-server-cisco ~]# ssh root@controller_server-1
Step 2 Enter the docker info command to display the disk space used by Docker containers:
[root@controller_server_1 ~]# docker info
Containers: 24
Images: 186
Storage Driver: devicemapper
Pool Name: vg_var-docker--pool
Pool Blocksize: 524.3 kB
Backing Filesystem: xfs
Data file:
Metadata file:
Data Space Used: 17.51 GB
Data Space Total: 274.9 GB
Data Space Available: 257.4 GB …
Reconfiguring SwiftStack Integration
Cisco VIM 2.2 provides integration with SwiftStack, an object storage solution. The key aspect of the SwiftStack integration is to add a SwfitStack endpoint to an existing pod running on Cisco VIM 2.2 through the reconfigure option. In this case the SwiftStack is installed and managed outside the Cisco VIM ahead of time, and the
VIM orchestrator adds the relevant Keystone configuration details to access the SwiftStack endpoint (see the
Cisco VIM 2.2 install guide for more details of SwiftStack).
The following options support the SwiftStack reconfiguration:
• Enable SwiftStack integration if it is not present.
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
121
Managing Cisco NFVI Storage
Integrating SwiftStack over TLS
• Reconfigure the existing SwiftStack PAC endpoint to point to a different cluster (cluster_api_endpoint).
• Reconfigure the Reseller_prefix of the existing SwiftStack installation.
• Reconfigure the admin password (admin_password) of an existing SwiftStack Install.
Integrating SwiftStack over TLS
The automation supports SwiftStack integration over TLS. To enable TLS, the CA root certificate must be presented as part of the
/root/openstack-configs/haproxy-ca.crt
file. The protocol parameter within the
SWIFTSTACK stanza must be set to https. As a pre-requisite, the SwiftStack cluster needs to be configured to enable HTTPS connections for the SwiftStack APIs with termination at the proxy servers.
The following section needs to be configured in the Setup_data.yaml file.
##########################################
# Optional Swift configuration section
##########################################
# SWIFTSTACK: # Identifies the objectstore provider by name
# cluster_api_endpoint: <IP address of PAC (proxy-account-container) endpoint>
# reseller_prefix: <Reseller_prefix as configured for Keysone Auth,AuthToken support in
Swiftstack E.g KEY_>
# admin_user: <admin user for swift to authenticate in keystone>
# admin_password: <swiftstack_admin_password>
# admin_tenant: <The service tenant corresponding to the Account-Container used by
Swiftstack protocol: <http or https> # protocol that swiftstack is running on top
Note The operator should pay attention while updating the settings to ensure that SwiftStack over TLS are appropriately pre-configured in the customer-managed SwiftStack controller as specified in the Install guide.
To initiate the integration, copy the setupdata into a local directory by running the following command:
[root@mgmt1 ~]# cd /root/
[root@mgmt1 ~]# mkdir MyDir
[root@mgmt1 ~]# cd MyDir
[root@mgmt1 ~]# cp /root/openstack-configs/setup_data.yaml <my_setup_data.yaml>
Update the setupdata by running the following command:
[root@mgmt1 ~]# vi my_setup_data.yaml (update the setup_data to include SwiftStack info)
Run the reconfiguration command as follows:
[root@mgmt1 ~]# cd ~/installer-xxxx
[root@mgmt1 ~]# ciscovim – -setupfile ~/MyDir/<my_setup_data.yaml> reconfigure
Cinder Volume Backup on SwiftStack
Cisco VIM 2.2 enables cinder service to be configured to backup its block storage volumes to the SwiftStack object store. This feature is automatically configured if the SWIFTSTACK stanza is present in the setup_data.yaml file. The mechanism is to authenticate against SwiftStack during volume backups leverages.
The same keystone SwiftStack endpoint is configured to manage objects. The default SwiftStack container
122
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
Managing Cisco NFVI Storage
Reconfiguring Administrator Source Networks that manages cinder volumes within the account (Keystone Tenant as specified by admin_tenant) is currently defaulted to volumebackups.
Reconfiguring Administrator Source Networks
To access the administrator services, Cisco VIM 2.2 provides source IP based filtering of network requests on the management node. These services include SSH and Kibana dashboard access. When the services are configured all admin network requests made to the management node are dropped, except those from white listed addresses in the configuration.
Reconfiguring administrator source network supports the following options:
• Set administrator source network list: Network addresses can be added or deleted from the configuration; the list is replaced in whole during a reconfigure operation.
• Remove administrator source network list: If the admin_source_networks option is removed, then the source address will not filter the incoming admin service requests.
The following section needs to be configured in the Setup_data.yaml file: admin_source_networks: # optional, host based firewall to white list admin's source IP
- 10.0.0.0/8
- 172.16.0.0/12
Note The operator should to be careful while updating the source networks. If the list is mis-configured, operators may lock themselves out of access to the management node through SSH. If this happens, an operator must log into the management node through the console port to repair the configuration.
To initiate the integration, copy the setupdata into a local directory by running the following command:
[root@mgmt1 ~]# cd /root/
[root@mgmt1 ~]# mkdir MyDir
[root@mgmt1 ~]# cd MyDir
[root@mgmt1 ~]# cp /root/openstack-configs/setup_data.yaml <my_setup_data.yaml>
Update the setupdata by running the following command:
[root@mgmt1 ~]# vi my_setup_data.yaml (update the setup_data to include SwiftStack info)
Run the reconfiguration command as follows:
[root@mgmt1 ~]# cd ~/installer-xxxx
[root@mgmt1 ~]# ciscovim – -setupfile ~/MyDir/<my_setup_data.yaml> reconfigure
Password Reset for Cisco VIM Management Node
.
Run the following command to reset the Root Password of Cisco VIM management node RHEL-7 / systemd
1 Boot your system and wait until the GRUB2 menu appears.
2 In the boot loader menu, highlight any entry and press e .
3 Find the line beginning with linux. At the end of this line, append the following: init=/bin/sh
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
123
Managing Cisco NFVI Storage
Password Reset for Cisco VIM Management Node
Or if you face any alarm, instead of ro change rw to sysroot as shown in the following example: rw init=/sysroot/bin/sh
4 Press Ctrl+X to boot the system using the options you just edited.
Once the system boots, you will be presented with a shell prompt without having to enter any user name or password: sh-4.2#
5 Load the installed SELinux policy by running the following command: sh-4.2# /usr/sbin/load_policy -i
6 Execute the following command to remount your root partition: sh4.2# mount -o remount,rw /
7 Reset the root password by running the following command: sh4.2# passwd root
When prompted, enter your new root password and confirm by pressing the Enter key. Enter the password for the second time to make sure you typed it correctly and confirm with Enter again. If both the passwords match, a message informing you of a successful root password change will appear.
8 Execute the following command to remount the root partition again, this time as read-only: sh4.2# mount -o remount,ro /
9 Reboot the system. Now you will be able to log in as the root user using the new password set up during this procedure.
To reboot the system, enter exit and exit again to leave the environment and reboot the system.
References: https://access.redhat.com/solutions/918283.
124
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
C H A P T E R
6
Overview to Cisco VIM Insight
Cisco VIM Insight is an optional application, which acts as a single point of management for the Cisco VIM.
If inclusive of your Cisco NFVI package, you can use Cisco VIM Insight to manage Cisco NFVI for day-0 and day-n and for multi-site and multi-pod management features.
•
Cisco VIM Insight Overview , page 125
•
Cisco VIM Insight Admin UI Overview, page 127
•
Cisco VIM Insight Pod UI Overview, page 127
Cisco VIM Insight Overview
Cisco VIM 2.2 provides an Intuitive and easy way to deploy and manage the NFVI platform, reducing user-error and providing visualization deployment which is a mechanism to manage multiple Cisco VIM Pods from a single portal. In CiscoVIM 2.2, a light-weight UI which is a dockerized application, that supports multi-tenancy with local RBAC support and CiscoVIM Rest layer are integrated. The container based UI platform manages multiple CiscoVIM pods right from day-0, or above in the lifecycle of the cloud.
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
125
Overview to Cisco VIM Insight
Cisco VIM Insight Overview
The architecture of the CiscoVIM Insight's interaction with a Pod is depicted below:
Figure 19: Cisco VIM Insight's Interaction with a Pod
The architecture of the CiscoVIM Insight is light-weight, hierarchical, and scalable. Each local site is autonomous with localized toolsets. Global Unified Management UI, provides ease of management with multi-site multi-pod capability for distributed NFV deployment at scale. This facility can be used through browsers such as IE, Firefox, Safari, and Chrome. CiscoVIM Insight by itself, is designed to operate in HA
126
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
Overview to Cisco VIM Insight
Cisco VIM Insight Admin UI Overview as an option. The platform is a modular, loosely coupled architecture, that provides the capability to manage multiple pods, with RBAC support as depicted in the following figure:
Figure 20: Cisco VIM Insight Architecture
The Cisco VIM insight can be installed in Standalone/non-HA mode: One can start off by installing in a
Standalone/non-HA mode (on the management node of the pod) or a standalone (BOM same as the management node) server.
As the UI interacts with each Pod through REST API and very little RBAC information of the Admin and user is kept in the DB, rendering the migrating from one install mode to another can be done effectively.
The UI has two types of views: As part of bootstrap UI Admin info is needed, you can add more users as UI and/or Pod Admin.
• UI Admin: UI Admin can add users as UI and/or Pod Admin.
• Pod Admin: Pod Admin have the privilege only at the Pod level, unless he is also an UI Admin.
Cisco VIM Insight Admin UI Overview
To ensure the right level of security and delegation, the Admin UI is responsible for management of UI and/or
Pod admin, which includes adding and revoking user privileges. Also, the UI Admin can delete an existing
Pod from the overall management pane.
Cisco VIM Insight Pod UI Overview
The Pod UI, is responsible for managing each Pod. VIM Insight gives easy access to switch between multiple
Pods, that is being managed by a given Pod Admin. Through the Pod UI, a Pod Admin can manage users and their respective roles and responsibilities. Also, the Pod UI provides the user to execute day-0 (install) and day-n (Pod management, software update, and so on.) activities seamlessly. ELK, Horizon Web UI, and so on are also cross-launched and visible for each Pod through the Pod UI.
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
127
Cisco VIM Insight Pod UI Overview
Overview to Cisco VIM Insight
128
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
C H A P T E R
7
Managing Cisco VIM through Insight
Cisco VIM Insight provides two types of views:
• UI Admin
• Pod Admin
This design brings in clear separation of roles. It does not store any pod related details obtained directly through Rest API from the pods locally, except for RBAC information.
•
UI Administrators Privileges and Responsibilities, page 129
•
Pod UI Privileges and Responsibilities, page 130
•
Adding Cisco VIM Pod, page 130
•
Deleting Pod from Cisco VIM insight, page 131
•
Context Switching within Insight, page 132
UI Administrators Privileges and Responsibilities
The Insight UI Admin has the following privileges and responsibilities:
1 Insight UI Admin(s) can only add Pod Admin.
2 Insight UI Admin can manage all the users in Insight from Manage Pod Users .
• UI Admin can revoke permission of Users: If UI Admin wants to revoke a user from a Pod, click
Revoke permission icon under Action column.
• UI Admin can also Delete a User: If UI Admin wants to delete a user from the Insight, Click Delete icon under Action column. If there is only one user associated with a Pod then UI Admin needs to delete the pod and then delete or revoke the user permission.
3 Insight UI Admin can manage Pod Admin(s) from Manage Pod Admin .
• UI Admin can add a new Pod Admin in Insight.
• UI Admin can revoke permission of a user from being a Pod Admin.
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
129
Managing Cisco VIM through Insight
Pod UI Privileges and Responsibilities
4 Insight UI Admin can manage Pods from Manage Pods.
• UI Admin can delete a Pod from Insight.
• UI Admin can also update password for the REST incase there was a system update on the pod and
REST password was changed in that process.
5 Insight UI Admin can manage other UI Admin(s) from Manage UI Admin Users .
• Insight UI Admin can add another UI Admin.
• Insight UI Admin can revoke permission of the user from being an UI Admin.
Note If there is only one UI Admin for Insight then revoke permission icon will be disabled for the user.
Pod UI Privileges and Responsibilities
As Cisco VIM is Rest API based, one can manage a pod through CLI, Rest API or UI. Users can always bring in a partial or fully functional Pod and register with VIM Insight. Insight will query the pod status through
Rest API and reflect the same. Despite the flexibility in design, it is recommended that the admin chooses to manage the pod one way, to avoid confusion. For steps to bootstrap VIM Insight, users are requested to refer to the VIM 2.2 Install guide. Post bootstrap of VIM Insight, listed below are the steps one can take to add
Cisco VIM Pod.
Adding Cisco VIM Pod
Before You Begin
Complete the following pre-requisites to add a Cisco VIM Pod:
• Bootstrap of VIM Insight is complete and successful as per the install guide.
• At minimum, a UI and Pod Admin exists as per the install guide.
Procedure
Step 1 Navigate to https://br_api:9000
Step 2 Click Register Management Node link.
• Enter the Endpoint IP which is the br_api of your Pod.
Note Run time validation to check if the Endpoint IP is already registered to Insight.
• Give a name or tag for the pod you are registering.
• Enter the REST API password for the Pod.
◦ You can locate the REST API password on the Pod you are registering.
130
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
Managing Cisco VIM through Insight
Deleting Pod from Cisco VIM insight
◦ The path to locate REST API password is : /opt/cisco/ui_config.json.
• A brief description about management node. Description field is optional and can be left blank.
• Enter the Email ID of the Pod Admin.
◦ Run time validation to check if the Email ID is Pod admin or not.
◦ If False, the Insight will throw an error "User is not registered as Pod Admin".
◦ If True, the User Name is auto-populated and the Register button will be enabled.
Step 3 Click Browse to upload restapi server CA Certificate. This is enabled once the POD Admin validation is successful.
• Navigate to /var/www/mercury/mercury-ca.crt
of the management node.
• Download the Certificate to the local machine and upload the certificate using Insight.
Note Validation check for file size and extension is done as a part of upload and in case of failure the
Certificate is deleted and you need to upload the valid certificate again.
If the Certificate is uploaded successfully then Register button is enabled. To do a management node health check click Register .
• If the REST API service is down on the management node then a failure message will be displayed as
: Installer REST API service not available. The certificate will not be deleted.
• If the Certificate is invalid and there is a SSL connection problem with the management node then certificate is deleted and message is displayed to upload the certificate again.
• If the Certificate is valid user is redirected to the login page with a message- management node registered successfully.
Step 4 Click Register to redirect the user to the landing or login page. Pod Admin receives the notification mail that the management node is registered successfully.
Deleting Pod from Cisco VIM insight
When you delete a Pod from Cisco VIM Insight, you are ensuring that Cisco VIM Insight cannot manage that
Cisco VIM Pod. You are not deleting the Pod from your OpenStack deployment.
Before You Begin
Following assumption should be covered to delete a Cisco VIM Pod:
• Bootstrap of VIM Insight is complete and successful as per the install guide.
• At least one UI and Pod Admin exists as per the install guide.
• The targeted Pod is being managed by Insight.
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
131
Managing Cisco VIM through Insight
Context Switching within Insight
Procedure
Step 1 Login as the Insight UI Admin.
Step 2 In the Navigation pane, click Manage Pods .
Step 3 Choose the pod that you want to delete in the Action column and click Delete .
Step 4 Click Proceed , to confirm the deletion.
Context Switching within Insight
There are two ways a user can switch to another pod.
• Context Switching Icon : Context Switching Icon is situated on the top right corner and is the third icon from the right tool tip of the UI. Click Context Switching Icon to view all the pods that you can access.
Pod with a red dot indicates that the REST Password entered during registration of Management node does not match with the current REST Password for that of particular node. In such a situation the Pod admin or User should reach out to UI admin to update the password for that Node. UI admin updates the password from Manage Pods in Insight UI admin Portal.
• Switch Between Management Nodes : Switch Between Management Nodes is available in the Dashboard.
The user can see all the pods in the table and can navigate to any Pod using a single click. If mouse pointer changes from hand or cursor to a red dot sign it indicates that the REST Password entered during registration of Management node does not match with the current REST Password for that particular node.
132
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
C H A P T E R
8
Managing Blueprints
The following topics tell you how to manage Cisco NFVI Blueprints.
•
•
Creating a Blueprint for B-Series Server Platform, page 134
•
Creating a Blueprint for C-Series Server Platform, page 149
•
Creating a Blueprint using Upload Functionality , page 165
•
Managing Post Install Features , page 168
Blueprints
Blueprints contain the configuration metadata required to deploy an OpenStack system through a Cisco VIM pod in Cisco VIM Insight. You can create a blueprint in Cisco Insight or you can upload a yaml file that contains the metadata for a blueprint. You can also create a blueprint from an existing OpenStack system that you are configuring as a Cisco VIM pod.
The configuration in the blueprint is specific to the type of Cisco UCS server that is in the OpenStack system.
A blueprint for a C-Series server-based OpenStack system cannot be used to configure a B-Series server-based
OpenStack system. Cisco Insight will display an error if the blueprint does not match the configuration of the
OpenStack system.
The blueprint enables you to quickly change the configuration of an OpenStack system. While only one blueprint can be active, you can create or upload multiple blueprints for a Cisco VIM pod. If you change the active blueprint for a pod, you update the configuration of the OpenStack system to match the new blueprint.
You can modify and validate an existing blueprint, or delete a blueprint. However, you cannot modify any of the configuration metadata in the active blueprint for a Cisco VIM pod.
Blueprint Activation
A blueprint becomes active when you use it in a successful installation for a Cisco VIM pod. Any other blueprints that you created or uploaded to that pod are in non-active state.
Uploading or creating a blueprint does not activate that blueprint for the pod. You need to install a blueprint through the Cisco VIM Suite wizard. If the installation is successful, the selected blueprint becomes active.
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
133
Managing Blueprints
Viewing Blueprint Details
Note If you want to activate a new blueprint in an existing pod, you need to delete certain accounts and the credential policies for that pod before you activate the blueprint. See
Activating a Blueprint in an Existing
Pod with OpenStack Installed, on page 166
.
Viewing Blueprint Details
You can view the details of an OpenStack installation blueprint. To view blueprint details:
Procedure
Step 1 Log in to Cisco VIM Insight as pod User.
Step 2 In the Dashboard's Switch between Management Nodes, select the Cisco VIM pod with the blueprint that you want to view.
Step 3 Click Menu button at the top left corner to expand the navigation pane.
Step 4 Choose Pre-Install > Blueprint Management.
Step 5 Choose a blueprint from the list.
Step 6 Click Preview & Download YAML.
Creating a Blueprint for B-Series Server Platform
Typically, you create the blueprint when you create the Cisco VIM pod. Follow the instructions below to create an additional blueprint for a pod that uses B-Series servers.
Before You Begin
Create a Cisco VIM Insight User Account and Register the respective Pod.
Procedure
Step 1 Log-in to Cisco VIM Insight.
Step 2 In the Navigation pane, expand the Pre-Install Section .
Step 3 Click Blueprint Setup .
Step 4 On the Blueprint Initial Setup page of the Cisco VIM Insight, complete the following fields:
Name Description
Blueprint Name field Enter the name for the blueprint configuration.
Platform Type drop-down list
• B-Series (By Default)
• C-Series
134
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
Managing Blueprints
Creating a Blueprint for B-Series Server Platform
Name
Tenant Network
Ceph Mode
Pod Type drop-down list drop-down list drop-down list
Optional Features and Services
Import Existing YAML field checkbox
Description
Choose one of the following tenant network types:
• Linux Bridge/VXLAN
• OVS/VLAN
Choose one of the following Ceph types:
• Dedicated (By Default)
• Central (not supported in production)
Fullon (By default).
Swiftstack, LDAP, Syslog Export Settings, Install
Mode, TorSwitch Information, TLS, Nfvmon, Pod
Name, VMTP, Nfvbench, Auto Backup, Heat,
Keystone v3.
If any one is selected, the corresponding section is visible in various Blueprint sections.
By default all options are disabled.
If you have an existing B Series YAML file you can use this feature to upload the file.
Insight will automatically fill in the fields and if any mandatory fields are missed then the respective section will be highlighted.
Step 5 Click Physical Setup to advance to the Registry Setup configuration page. Fill in the following details for
Registry Setup:
Name Description
Registry User Name text field User-Name for Registry (Mandatory).
Registry Password
Registry Email text field text field
Password for Registry (Mandatory).
Email ID for Registry (Mandatory).
Once all mandatory fields are filled the Validation Check Registry page will be changed to a Green Tick.
Step 6 Click UCSM Common tab and fill the following fields:
Name Description
User name disabled field By default value is admin.
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
135
Managing Blueprints
Creating a Blueprint for B-Series Server Platform
Name
Password
UCSM IP text field text field
Resource Prefix
QOS Policy Type
MRAID-CARD text field drop-down list
Enable Prov FI PIN optional checkbox optional checkbox
Enable UCSM Plugin
Enable QoS Policy optional checkbox optional checkbox
SRIOV Multi VLAN Trunk optional grid
Description
Enter Password for UCSM Common (Mandatory).
Enter IP Address for UCSM Common (Mandatory).
Enter the resource prefix (Mandatory)
Choose one of the following types:
• NFVI (Default)
• Media
Default is false.
Enables JBOD mode to be set on disks. Applicable only if you have RAID controller configured on
Storage C240 Rack servers.
Visible when Tenant Network type is OVS/VLA.
Visible only when UCSM Plugin is enabled. If UCSM
Plugin is disabled then this option will be set to False.
Visible when UCSM Plugin is enabled. Enter the values for network and vlans ranges. Grid can handle all CRUD operations like Add, Delete, Edit and
Multiple Delete.
Step 7 Click Networking to advance to the networking section of the Blueprint.
Name Description
Domain Name field Enter the domain name (Mandatory).
NTP Servers field
Domain Name Servers field
Enter a maximum of four and minimum of one IPv4 and/or IPv6 addresses in the table.
Enter a maximum of three and minimum of one IPv4 and/or IPv6 addresses.
HTTP Proxy Server field
HTTPS Proxy Server field
If your configuration uses an HTTP proxy server, enter the IP address of the server.
If your configuration uses an HTTPS proxy server, enter the IP address of the server.
136
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
Managing Blueprints
Name
Network table
Creating a Blueprint for B-Series Server Platform
Description
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
137
Creating a Blueprint for B-Series Server Platform
Name
138
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
Managing Blueprints
Description
Network table is pre-populated with Segments. To add Networks you can either clear all the table using
Delete all or click Edit icon for each segment and fill in the details.
You can add, edit, or delete network information in the table.
• Click Edit to enter new entries (networks) to the table.
• Specify the following fields in the Edit Entry to Networks dialog:
Segment drop-down list You can select any of one segment from dropdown list
• API
• Management
Provision
• Tenant
• CIMC
• Storage
• External
• Provider (optional)
IPv6 Subnet field
Note Depending upon the segment not all entries listed below are needed
Enter Ipv6 Address. This field will be available only for Management provision and API .
VALN field
Subnet field.
Enter the VLAN ID. For
Segment - Provider, the
VLAN ID value is always none .
Enter the IPv4 address for the subnet.
Managing Blueprints
Creating a Blueprint for B-Series Server Platform
Name Description
Gateway field
IPv6 Gateway field
Pool field
IPv6 Pool field.
Enter the IPv4 address for the Gateway.
Enter IPv6 gateway. This field is only available for the Mgmt/Provision,
Storage, and API
Segments.
Enter the pool information in the required format:
Example: 10.30.1.1 or
10.30.1.1 to 10.30.1.12
Enter the pool information in the required format, for example:
10.1.1.5-10.1.1.10,10.2.1.5-10.2.1.10
This field is only available for the
Mgmt/Provision,
Storage, and Tenant segments.
Click Save .
Step 8 On the Servers and Roles page of the Cisco VIM Suite wizard, click Add (+) to add a new entry in the table, and complete the following fields:
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
139
Managing Blueprints
Creating a Blueprint for B-Series Server Platform
Name
Add Entry to Servers and Roles .
Description
Click Edit or + to add a new server and role to the table.
Server Name Enter a server name.
Server Type drop-down list.
Choose Blade or Rack from the drop-down list.
Rack ID field.
Chassis ID field
If Rack is chosen, the
Rack Unit ID field is displayed.
If Blade is chosen, the
Blade ID field is displayed.
The Rack ID for the server.
Enter a Chassis ID.
Enter a Rack Unit ID.
Enter a Blade ID.
Select the Role from the drop down list.
If Server type is Blade then Control and
Compute. If Rack is selected then Block
Storage.
Management IP field.
It is an optional field but if provided for one server then it is mandatory to provide it for other Servers as well.
Management IPv6 field.
Enter Management Ipv6 address.
Click Save or Add.
Disable Hyperthreading
Clicking Save or Add , adds all information for
Servers and Roles.
Fill in all mandatory fields.
True or False . Default is false.
Step 9 Click ToR Switch checkbox in Blueprint Initial Setup to enable the TOR SWITCH configuration page. It is an Optional section in Blueprint Setup, but once all the fields are filled in then it will become a part of the
Blueprint.
140
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
Managing Blueprints
Creating a Blueprint for B-Series Server Platform
Name
Configure ToR optional checkbox .
ToR Switch Information mandatory table if you want to enter ToR information.
Description
If you enable this checkbox, the Configure ToR section will change from false to true.
Click + to add information for Tor Switch.
Name
Name
Description
ToR switch name.
Username ToR switch username.
Password
SSH IP
SSN Num
VPC Peer Keepalive
ToR switch Password.
ToR switch SSH IP
Address.
ToR switch ssn num.
output of show license host-id.
Peer Management IP.
You need not define if there is no peer as it is optional but it will become mandatory when the ToR is in VPC.
VPC Domain
VPC Peer port
Need not define if there is no peer.
Interface for vpc peer ports.
VPC Peer VLAN Info vlan ids for vpc peer ports (optional).
BR Management Port
Info
Management interface of build node.
BR Management PO
Info
Port channel number for management interface of build node.
On clicking Save , Add ToR Info connected to Fabric field will be visible.
Port Channel field.
Switch Name field.
Enter the port channel input.
Enter the switch name.
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
141
Managing Blueprints
Creating a Blueprint for B-Series Server Platform
Step 10 Click OpenStack Setup tab to advance to the OpenStack Setup Configuration page.
Step 11 On the OpenStack Setup page of the Cisco VIM Insight wizard, complete the following fields:
Name Description
HA Proxy Fill in the mandatory fields:
External VIP Address Enter IP address of
External VIP.
External VIP Address
IPv6
Virtual Router ID
Enter IPv6 address of
External VIP.
Enter the Router ID for
HA.
Internal VIP Address
IPv6
Enter IPv6 address.
Internal VIP Address Enter IP address of Internal
VIP.
Keystone Mandatory fields are pre-populated. This option is always true.
Admin Username admin.
Admin Tenant Name admin.
142
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
Managing Blueprints
Creating a Blueprint for B-Series Server Platform
Name Description
LDAP .
Note: this option is only available with Keystone v3
This is available only when Keystone v3 and LDAP both are enabled under Optional Features and Services in
Blueprint Initial Setup.
Domain Name field Enter name for Domain name.
Object Class for Users field
Enter a string as input.
Object Class for Groups Enter a string.
Domain Name Tree for
Users
Enter a string.
Domain Name Tree for
Groups field
Enter a string.
Suffix for Domain Name field
Enter a string.
URL field Enter a URL with ending port number.
Domain Name for Bind
User field
Enter a string.
Password field Enter Password as string format.
User Filter
User ID Attribute
Enter filter name as string.
Enter a string.
User Name Attribute
User Mail Attribute
Enter a string.
Enter a string.
Group Name Attribute Enter a string.
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
143
Creating a Blueprint for B-Series Server Platform
Name
Neutron
Managing Blueprints
Description
Neutron fields change on the basis of Tenant Network
Type Selection from Blueprint Initial Setup page.
Following are the options available for Neutron for
OVS/VLAN:
Tenant Network Type Auto Filled based on the
Tenant Network Type selected in the Blueprint
Initial Setup page.
Mechanism Drivers
NFV Hosts
Tenant VLAN Ranges
Auto Filled based on the
Tenant Network Type selected in Blueprint Initial
Setup page.
Auto filled with the
Compute you added in
Server and Roles.
If you select All in this section NFV_HOSTS:
ALL will be added to the
Blueprint or you can select one particular compute.
For Eg:
NFV_HOSTS: compute-server-1, compute-server-2.
List of ranges separated by comma of form start:end.
Provider VLAN Ranges List of ranges separated by comma of form start:end.
VM Hugh Page Size
(available for
NFV_HOSTS option)
2M or 1G
Enable Jumbo Frames Check Box
For Tenant Network Type Linux Bridge, everything will remain the same except Tenant VLAN Ranges which will be removed.
144
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
Managing Blueprints
Name
CEPH
GLANCE
CINDER
Creating a Blueprint for B-Series Server Platform
Description
Ceph has two pre-populated fields
• CEPH Mode : By default Dedicated .
• NOVA Boot from: From the drop-down, choose
Ceph or local .
By default Populated for CEPH Dedicated with Store
Backend value as CEPH .
By default Populated for CEPH Dedicated with Volume
Driver value as CEPH .
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
145
Creating a Blueprint for B-Series Server Platform
Name
VMTP optional section will only be visible once
VMTP is selected from Blueprint Initial Setup.
Description
Managing Blueprints
146
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
Managing Blueprints
Name
Creating a Blueprint for B-Series Server Platform
Description
Check one of the check boxes to specify a VMTP network:
• Provider Network
• External Network
For the Provider Network complete the following:
Network Name field.
Enter the name for the external network.
IP Start field.
IP End field.
Gateway field
Enter the starting floating
IPv4 address.
Enter the ending floating
IPv4 address.
Enter the IPv4 address for the Gateway.
DNS Server field.
Segmentation ID
Subnet field.
Enter the DNS server IPv4 address.
Enter the segmentation ID.
Enter the Subnet for
Provider Network.
For External Network fill in the following details:
Network Name field.
Enter the name for the external network.
Network IP Start field.
Network IP End field.
Enter the starting floating
IPv4 address.
Enter the ending floating
IPv4 address.
Network Gateway field Enter the IPv4 address for the Gateway.
DNS Server field.
Subnet
Enter the DNS server IPv4 address.
Enter the Subnet for
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
147
Managing Blueprints
Creating a Blueprint for B-Series Server Platform
Name Description
External Network.
TLS section will be visible if TLS is selected from Blueprint Initial Setup Page.
TLS has two options:
• External LB VIP FQDN Text Field.
• External LB VIP TLS - True/False . By default this option is false.
SwiftStack optional section will be visible if
SwiftStack is selected from Blueprint Initial
Setup Page. SwiftStack is only supported with
KeyStonev2 . If you select Keystonev3 , swiftstack cannot be configured.
Following are the options that needs to be filled for
SwiftStack:
Cluster End Point IP address of PAC
(proxy-account-container) endpoint.
Admin User
Admin Tenant
Admin user for swift to authenticate in keystone.
The service tenant corresponding to the
Account-Container used by Swiftstack.
Reseller Prefix
Admin Password
Protocol
Reseller_prefix as configured for Keysone
Auth,AuthToken support in Swiftstack E.g KEY_ swiftstack_admin_password http or https
Under the openstack setup tab, the Vim_admins tab will only be visible once Vim_admins is selected from the Optional Features & Services under the Blueprint InitialSetup tab.
Following are the options that needs to be filled for Vim
Admins:
• Username - Text Field
• Password - Password field. Admin hash password should always start with $6
Step 12 If Syslog Export or NFVBENCH is selected in Blueprint Initial Setup Page, then Services Setup page would be enabled for user to view. Following are the options under Services Setup Tab :
148
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
Managing Blueprints
Creating a Blueprint for C-Series Server Platform
Name
Syslog Export
NFVBENCH
.
Description
Following are the options for Syslog Settings:
Remote Host Enter Syslog IP Address
Facility
Severity
Defaults to local5
Defaults to debug
Clients
Port
Protocol
Defaults to ELK
Defaults to 514 but can be modified by the User.
Supports only UDP
Enable checkbox which by default is False .
Add Tor information connected to switch:
• Select a TOR Switch and Enter the Switch name.
• Enter the port number. For example: eth1/5. VTEP
VLANS (mandatory and needed only for VXLAN):
Enter 2 different VLANs for VLAN1 and VLAN2.
• NIC Ports: INT1 and INT2 optional input. Enter the
2 port numbers of the 4-port 10G Intel NIC at the management node used for NFVBench.
Step 13 Click Offline validation to initiate an offline Blueprint validation.
Step 14 Once the Offline validation is successful, Save option will be enabled which will redirect you to the Blueprint
Management page.
Creating a Blueprint for C-Series Server Platform
Procedure
Step 1 Log-in to CISCO VIM Insight .
Step 2 In the Navigation pane, expand the Pre-Install Section .
Step 3 Click Blueprint Setup .
Step 4 On the Blueprint Initial Setup page of the Cisco VIM Insight , complete the following fields:
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
149
Managing Blueprints
Creating a Blueprint for C-Series Server Platform
Name
Blueprint Name
Platform Type field drop-down list
Tenant Network
Pod Type drop-down list
Ceph Mode drop-down list drop-down list
Optional Features and Services checkbox.
Description
Enter the name for the blueprint configuration.
• B-Series (By Default)
• C-Series ( Select C Series)
Choose one of the following tenant network types:
• Linux Bridge/VXLAN
• OVS/VLAN
• VTS/VLAN
• VPP/VLAN
• ACI/VLAN
Note when VTS/VLAN or ACI/VLAN is selected then respective tabs are available on
Blueprint setup
Choose one of the following pod type :
• Fullon(By Default)
• Micro
• UMHC
Note
Note
UMHC pod type is only supported for
OVS/VLAN tenant type.
Pod type micro is supported for OVS/VLAN,
ACI/VLAN,VPP/VLAN.
Choose one of the following Ceph types:
• Dedicated (By Default)
• Central
Swiftstack, LDAP, Syslog Export Settings, Install
Mode, TorSwitch Information, TLS, Nfvmon, Pod
Name, VMTP, Nfvbench, Auto Backup, Heat,
Keystone v3
If any one is selected, the corresponding section is visible in various Blueprint sections.
By default all options are disabled.
150
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
Managing Blueprints
Creating a Blueprint for C-Series Server Platform
Name
Import Existing YAML file
Description
If you have an existing C Series YAML file you can use this feature to upload the file.
Insight will automatically fill in the fields and if any mandatory field is missed then would highlight it in the respective section.
Step 5 Click Physical Setup to advance to the Registry Setup configuration page. Fill in the following details for
Registry Setup.
Name Description
Registry User Name text field User-Name for Registry (Mandatory).
Registry Password
Registry Email text field text field
Password for Registry (Mandatory).
Email ID for Registry (Mandatory).
Once all Mandatory fields are filled, the Validation Check Registry page will indicate a green tick.
Step 6 Click CIMC Common tab and complete the following fields:
Name Description
User Name disabled field By default value is Admin.
Password text field Enter Password for UCSM Common (Mandatory).
Step 7 Click Networking to advance to the networking section of the Blueprint.
Name Description
Domain Name field.
Enter the domain name (Mandatory).
NTP Servers field.
Enter a maximum of four and minimum of one IPv4 and/or IPv6 addresses in the table.
Domain Name Servers field
HTTP Proxy Server
HTTPS Proxy Server field field.
Enter a maximum of three and minimum of one IPv4 and/or IPv6 addresses
If your configuration uses an HTTP proxy server, enter the IP address of the server.
If your configuration uses an HTTPS proxy server, enter the IP address of the server.
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
151
Managing Blueprints
Creating a Blueprint for C-Series Server Platform
Name
Networks table
Description
Network table is pre-populated with segments. To add Networks you can either clear all the table using
Delete all or click Edit icon for each segment and fill in the details.
You can add, edit, or delete network information in the table.
Step 8 Click Edit to enter new entries (networks) to the table. Specify the following fields in the Edit Entry to
Networks dialog:
Name Description
Segment drop-down list Default is already elected.
When you add/edit the segment then the following are the segment types available and you can select only one from dropdown list.
• API
• Management/provision
• Tenant
• Storage
• External
• Provider
• ACIINFRA
VLAN
Subnet field field
Note Aciinfra segment is available only when
ACI/VLAN tenant type is selected)
Depending upon the segment some of the entries below are not needed. Please refer to the example file in openstack-configs dir for details.
Enter the VLAN ID. For Segment - Provider , the
VLAN ID value is always none .
Enter the IPv4 address for the subnet.
IPv6 Subnet field
Gateway field
IPv6 Gateway field
Enter Ipv6 Address. This field will be available only for Management provision and API.
Enter the IPv4 address for the Gateway.
Enter the IPv6 address for the Gateway. This will support for API and management provision
152
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
Managing Blueprints
Creating a Blueprint for C-Series Server Platform
Name
Pool field
IPv6 Pool field
Description
Enter the pool information in the required format, for example: 10.1.1.5-10.1.1.10,10.2.1.5-10.2.1.10
This field is only available for the Mgmt/Provision,
Storage, and Tenant segments.
Enter the pool information in the required format, for example: 10.1.1.5-10.1.1.10,10.2.1.5-10.2.1.10
This field is only available only for Management provision
Click Save .
Step 9 On the Servers and Roles page of the Cisco VIM Suite wizard, click Add (+) to add a new entry in the table, and complete the following fields:
You can edit or delete existing entries in the Server and Roles table.
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
153
Managing Blueprints
Creating a Blueprint for C-Series Server Platform
Name
Add Entry to Servers and Roles .
Note when Pod type micro is selected then all the three servers will be associated with control, compute and block storage role.
For Example:
Roles
• Block Storage
◦ -Server 1
◦ -Server 2
◦ -Server 3
•
•
Control
◦ -Server 1
◦ -Server 2
◦ -Server 3
Compute
◦ -Server 1
◦ -Server 2
◦ -Server 3
Description
Click Edit or + to add a new server and role to the table.
Server Name Entry the server name .
Rack ID field The rack ID for the server.
VIC Slot field
Management IPv6 field
CIMC IP field
CIMC Username field
CIMC Password field
Enter a VIC Slot.
This is optional field. Enter
Ipv6 format address
Enter a IP address.
Enter a Username.
Enter a Password for CIMC
Select the Role from the drop down list
Choose Control or Compute or Block Storage from the drop-down list.
Management IP It is an optional field but if provided for one server then it is mandatory to provide it for other servers.
Note When Pod type UMHC is selected then auto ToR configuration is not supported and the ToR info at server and roles level is not allowed to be entered.
Click Save or Add .
On clicking Save or Add all information related to Servers and Roles gets saved.
If Configure ToR checkbox is True with at-least one switch detail, these fields will be displayed for each server and this is similar to DP Tor: Port Channel and Switch Name
(Mandatory if Configure ToR is true)
•
•
•
Port Channel
Switch Name field field
Switch Port Info field
•
•
Enter the port channel input.
Enter the switch name.
• Enter the switch port information.
154
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
Managing Blueprints
Creating a Blueprint for C-Series Server Platform
Name
DP ToR (Only for Control and Compute) :
Mandatory if Intel NIC and Configure TOR is True.
Description
•
•
Port Channel
Switch Name field field
• Switch Port Info field
• Enter the port channel input.
• Enter the switch name.
• Enter the switch port information.
SRIOV TOR INFO (Only for Compute
Nodes). It is mandatory in server and roles if Intel NIC and Configure TOR is True.
Switch Name (Mandatory if Configure
ToR is true).
This field appears only when
Intel NIC support is true, as Auto TOR config is not supported in VIC_NIC combo
Intel SRIOV VFS (valid for Intel NIC testbeds) and can be integer.
•
• Port Channel
Switch-Name field.
field.
•
• Enter the Port channel.
Enter the string.
For SRIOV support for Intel NIC. By Default, SRIOV support is disabled. To enable, define a value in the range # * 1-32 when INTEL_NIC_SUPPORT is set True (X710 Max VFs =
32) # * 1-63 when CISCO_VIC_INTEL_SRIOV is set True
(X520 Max VFs = 63)
INTEL_SRIOV_PHYS_PORTS (valid for
Intel NIC test beds) and can be of value 2 or
4 (default is 2)
In some cases the # of Physical SRIOV port needed is 4; to meet that requirement, define the following: # this is optional, if nothing is defined code will assume it to be 2; the only 2 integer values this parameter # takes is 2 or 4 and is true when
INTEL_NIC_SUPPORT is True and INTEL_SRIOV_VFS is valid
Click Save or Add .
Disable Hyper threading
On clicking Save or Add all information related to Servers and Roles gets saved.
Default value is false. You can set it as true or false.
Click Save or Add button.
If all mandatory fields are filled, click Save or Add button information for Servers and Roles.
Note
Note
Maximum two ToR info needs to be configured for each connection type on each node (control, compute and block_storage node).
If pod type UMHC is selected then CISCO_VIC_INTEL_SRIOV is enabled to be TRUE.
Note For Tenant type ACI/VLAN, port channel for each ToR port will not be available in servers and roles, as APIC will automatically assign port-channel numbers.
Step 10 Click ToR Switch checkbox in Blueprint Initial Setup to enable the TOR SWITCH configuration page. It is an Optional section in Blueprint Setup but once all the fields are filled, it becomes a part of the Blueprint.
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
155
Managing Blueprints
Creating a Blueprint for C-Series Server Platform
Name
Configure TOR optional checkbox.
Note If UMHC is selected as podtype, configure TOR is not allowed.
Description
If you enable this checkbox configure tor section would be changed from false to true.
Note Configure tor is true then ToR switch info maps in servers
TOR Switch Information mandatory table if you want to enter ToR information.
Click + to add information for ToR Switch.
Name Description
Name ToR Switch Name.
Username TOR switch username
Password
SSH IP
SSN Num
VPC Peer Keepalive
ToR switch Password
TOR switch ssh ip
TOR switch ssn num
Peer Management IP. Do not define if there is no peer
VPC Domain
VPC Peer Port Info
Do not define if there is no peer
Interface for vpc peer ports
VPC Peer VLAN Info vlan ids for vpc peer ports
(optional)
BR Management Port Info Management interface of build node
BR Management PO Info Port channel number for management interface of build node
Click Save .
Note When tenant type ACI/VLAN is selected, the TOR switch information table differs and is mandatory.
Name
Configure ToR
Description
Is not checked, as by default ACI will configure the
ToRs
156
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
Managing Blueprints
Creating a Blueprint for C-Series Server Platform
Click + to add information for ToR Switch
Name
Host Name
Description
ToR switch name.
VPC Peerkeep alive Peer info must exist in pair.
VPC Domain Enter an Integer.
BR Management Port
Info
Enter Br management port info eg. Eth1/19, must have a pair in the peer switch.
Enter Node ID Entered Integer must be unique.
Step 11 Click OpenStack Setup Tab to advance to the OpenStack Setup page.
Step 12 In the OpenStack Setup page of the Cisco VIM Insight wizard, complete the following fields:
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
157
Managing Blueprints
Creating a Blueprint for C-Series Server Platform
Name
Neutron
CEPH
GLANCE
158
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
Description
Neutron fields would change on the basis of Tenant
Network Type Selection from Blueprint Initial Setup .
Following are the options available for Neutron:
Tenant Network Type Auto Filled based on the
Tenant Network Type selection in Blueprint Initial
Setup page.
Mechanism Drivers
NFV Hosts
Auto Filled based on the
Tenant Network Type selection in Blueprint Initial
Setup page.
Auto filled with the Compute you added in Server and
Roles. If you select All in this section NFV_HOSTS:
"ALL" will be added to the
Blueprint or else you can select particular computes as well for eg: NFV_HOSTS:
"compute-server-1, compute-server-2"
Tenant VLAN Ranges Only with VTS/VLAN and
VPP/VLAN.
Enable Jumbo Frames Check Box default is false.
Huge page size Note : .
This is available only when Compute node is present in NFV host
The following are the drop-downs:
• 2M
• 1G
For Tenant Network Type Linux Bridge everything will remain the same but Tenant VLAN Ranges will be removed.
Ceph has two pre-populated fields
• CEPH Mode : By default Dedicated.
• NOVA Boot from: Drop Down selection. You can choose Ceph or local.
By default populated for CEPH Dedicated with Store
Backend value as CEPH .
Managing Blueprints
Name
CINDER
HA Proxy
Keystone
Creating a Blueprint for C-Series Server Platform
Description
By default Populated for CEPH Dedicated with Volume
Driver value as CEPH .
External VIP Address
External VIP Address
IPv6
Virtual Router ID
Internal VIP Address
Internal VIP Address
IPv6
Enter IP Address of
External VIP.
Enter IP Address of
External VIP for IPv6.
Enter the Router ID for
HA.
Enter IP Address of
Internal VIP.
Enter the IP Address for
Internal VIP IPv6.
Admin Username
Admin Tenant Name admin admin
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
159
Creating a Blueprint for C-Series Server Platform
Name
LDAP
Managing Blueprints
Description
This is available only when Keystone v3 and LDAP both are enabled under Optional Features and Services in
Blueprint Initial Setup.
Domain Name field Enter name for Domain name.
Object Class for Users field
Enter a string as input.
Object Class for Groups Enter a string.
Domain Name Tree for
Users
Enter a string.
Domain Name Tree for
Groups field
Enter a string.
Suffix for Domain Name field
Enter a string.
URL field Enter a URL with ending port number.
Domain Name for Bind
User field
Enter a string.
Password field Enter Password as string format.
User Filter
User ID Attribute
Enter filter name as string.
Enter a string.
User Name Attribute
User Mail Attribute
Enter a string.
Enter a string.
Group Name Attribute Enter a string.
160
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
Managing Blueprints
Creating a Blueprint for C-Series Server Platform
Name
VMTP optional section will only be visible once
VMTP is selected from Blueprint Initial Setup.
Note For VTS, Provider network is only supported
Description
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
161
Creating a Blueprint for C-Series Server Platform
Name
162
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
Managing Blueprints
Description
Check one of the check boxes to specify a VMTP network:
• Provider Network
• External Network
For the Provider Network complete the following:
Network Name field Enter the name for the external network.
IP Start field
IP End field
Gateway field
DNS Server field
Segmentation ID
Subnet field
Enter the starting floating
IPv4 address.
Enter the ending floating
IPv4 address.
Enter the IPv4 address for the Gateway.
Enter the DNS server IPv4 address.
Enter the segmentation ID.
Enter the Subnet for
Provider Network.
For External Network fill in the following details:
Network Name field Enter the name for the external network.
Network IP Start field Enter the starting floating
IPv4 address.
Network IP End field Enter the ending floating
IPv4 address.
Network Gateway field Enter the IPv4 address for the Gateway.
DNS Server field
Subnet
Enter the DNS server IPv4 address.
Enter the Subnet for
External Network.
Managing Blueprints
Creating a Blueprint for C-Series Server Platform
Name Description
TLS This optional section will only be visible once TLS is selected from Blueprint Initial Setup
Page.
TLS has two options:
• External LB VIP FQDN Text Field.
• External LB VIP TLS True/False. By default this option is false.
SwiftStack optional section will be visible once
SwiftStack is selected from Blueprint Initial
Setup Page. SwiftStack is only supported with
KeyStonev2 . If you select Keystonev3, swiftstack will not be available for configuration.
Following are the options that needs to be filled for
SwiftStack:
Cluster End Point IP address of PAC
(proxy-account-container) endpoint.
Admin User
Admin Tenant
Admin user for swift to authenticate in keystone.
The service tenant corresponding to the
Account-Container used by Swiftstack.
Reseller Prefix
Admin Password
Protocol
Reseller_prefix as configured for Keysone
Auth,AuthToken support in Swiftstack E.g KEY_ swiftstack_admin_password http or https. Protocol that swiftstack is running on top
Note
Note
When tenant type ACI/VLAN is selected then ACI INFO tab is available in blueprint setup.
When ACI/VLAN is selected then Tor switch from initial setup is mandatory.
Name
APIC Hosts field apic_username apic_password field filed
Description
Enter host input. Example: <ip1|host1>:[port] . max of 3, min of 1, not 2;
Enter a string format.
Enter Password.
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
163
Managing Blueprints
Creating a Blueprint for C-Series Server Platform
Name apic_system_id field apic_resource_prefix field apic_tep_address_ pool field multiclass_address_pool field apic_pod_id field apic_installer_tenant field apic_installer_vrf field api_l3out_network field
Description
Enter input as string. Max length 8.
Enter string max length 6.
Allowed only 10.0.0.0/16
Allowed only 225.0.0.0/15
Enter integer(1- 65535)
Enter String, max length 32
Enter String, max length 32
Enter String, max length 32
Note When Tenant Type is VTS/VLAN then VTS tab is available in blueprint setup.
VTS Day0 (checkbox)
VTS User name
VTS Password
VTS NCS IP
VTC SSH Username
VTC SHH Password
True or false default is false.
Enter as string does not contain special characters.
Enter password
Enter IP Address format.
Enter a string
Enter password
Note If vts day0 is enabled then SSH username and SSH password is mandatory.
If SSH_username is input present then SSH password is mandatory vice-versa
Step 13 If Syslog Export or NFVBENCH is selected in Blueprint Initial Setup Page then, Services Setup page will be enabled for User to view. Following are the options under Services Setup Tab:
Name Description
164
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
Managing Blueprints
Creating a Blueprint using Upload Functionality
Syslog Export
NFVBENCH
Following are the options for Syslog Settings:
Remote Host
Protocol
Facility
Severity
Clients
Port
Enter Syslog IP Address.
Only UDP is supported.
Defaults to local5.
Defaults to debug.
Defaults to ELK
Defaults to 514 but can be modified by the User.
Enable checkbox which by default is false .
Add ToR info connected to switch:
• Select a TOR Switch. Switch- (switch name)
• Enter the port number. For Example: eth1/5 .
VTEP VLANS (mandatory and needed only for
VTS/VXLAN,): Enter 2 different VLANs for
VLAN1 and VLAN2.
• NIC Ports: INT1 & INT2 Optional input, enter the 2 port numbers of the 4-port 10G Intel NIC at the management node used for NFVBench.
Step 14 Click Offline validation button to initiate an offline validation of the Blueprint.
Step 15 Once the Offline validation is successful, Save option will be enabled for you which when clicked would redirect you to the Blueprint Management Page.
Creating a Blueprint using Upload Functionality
Before You Begin
• You should have a YAML file (B series or C Series) on your system.
• Only one blueprint can be uploaded at a time. To create a blueprint off-line, please refer to the setup_data.yaml.B_Series_EXAMPLE or setup_data.yaml.C_Series_EXAMPLE.
• The respective keys in the sample YALM should match or the corresponding section will not be populated during upload.
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
165
Managing Blueprints
Activating a Blueprint in an Existing Pod with OpenStack Installed
Procedure
Step 1 Log-in to CISCO VIM Insight .
Step 2 In the Navigation pane, expand the Pre-Install Section.
Step 3 Click Blueprint Setup.
Step 4 Click the Browse button in the Blueprint Initial Setup page.
Step 5 Click Select .
Step 6 Click on Load button in the Insight UI Application .
All the fields present in the YAML file will be uploaded to the respective fields in the UI.
Step 7 Provide a Name for the Blueprint .
Make sure the blueprint name is unique while saving it.
Step 8 Click Offline Validation .
• If all the mandatory fields in the UI are populated, then Offline Validation of the Blueprint will commence, or else a pop up message indicating the section of Blueprint Creation that has missing information error shows up.
Step 9 On Offline Blueprint Validation being successful , Save Blueprint and Cancel button will be enabled.
Note If the Blueprint Validation Fails, only the Cancel button will be enabled.
Activating a Blueprint in an Existing Pod with OpenStack Installed
Before You Begin
You must have a POD which has an active Installation of OpenStack. If the OpenStack installation is in Failed
State, then Insight UI will not be able to fetch the Blueprint.
Procedure
Step 1 Go to the landing page of the Insight Login.
Step 2 Click Register Management Node .
Step 3 Enter the following details:
• Management Node IP Address.
• Management Node Name (Any friendly Name).
• REST API Password ( /opt/cisco/ui_config.json).
• Description about the Management Node.
• POD Admin's Email ID.
166
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
Managing Blueprints
Downloading Blueprint
A notification email will be sent to the email id entered during registration.
Step 4 Login using the same email id and password.
Step 5 In the Navigation pane, click Pre-Install > Blueprint Management .
In the Blueprint Management Page you will see NEWSETUPDATA .
This is the same setup data which was used by ciscovimclient to run the installation on the Management Node.
Downloading Blueprint
Before You Begin
You must have atleast one blueprint (In any state Active/In-Active or In-progress), in the Blueprint
Management Page .
Procedure
Step 1 Log-in to CISCO VIM Insight .
Step 2 In the Navigation pane, expand the Pre-Install Section .
Step 3 Click Blueprint Management .
Step 4 Go-to Download button for any Blueprint under Action title. ( Download Button > Downward Arrow (with tooltip Preview & Download YAML).
Step 5 Click the Download icon.
A pop to view the Blueprint in the YAML format will be displayed.
Step 6 Click the Download button at the bottom left of the pop-up window.
YAML will be saved locally with the same name of the Blueprint.
Validating Blueprint
Procedure
Step 1 Log-in to CISCO VIM Insight .
Step 2 In the Navigation pane, expand the Pre-Install Section .
Step 3 Click Blueprint Creation .
Step 4 Upload an existing YAML, or create a New Blueprint .
Fill all the mandatory fields so that all Red Cross changes to Green Tick .
Step 5 Enter the name of the Blueprint.
Step 6 Click the Offline Validation button.
Only if the Validation is successful, the Insight will allow the user to save the blueprint.
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
167
Managing Blueprints
Managing Post Install Features
What to Do Next
If you see any errors, then hyperlink will be created for those errors. Click on the link to be navigated to the page where error has been encountered.
Managing Post Install Features
Cisco VIM provides an orchestration that helps in lifecycle management of a cloud. VIM is responsible for pod management activities which includes fixing both hardware and software issues with one-touch automation.
VIM Insight provides the visualization of the stated goal. As a result, it integrates with POST install features that Cisco VIM offers through its Rest API. These features are enabled only if there is an active Blueprint deployment on the pod.
Monitoring the Pod
In VIM 2.2, we use EFK (Elasticsearch, Fluentd and Kibana) to monitor the OpenStack services, by cross-launching the Kibana dashboard.
To cross launch Kibana, complete the following instructions:
Procedure
Step 1 In the Navigation pane, click Post-Install > Monitoring .
The Authentication Required browser pop up is displayed.
Step 2 Enter the username as Admin.
Step 3 Enter the ELK_PASSWORD password obtained from /root/installer-<tagid>/openstack-configs/secrets.yaml
in the management node.
Kibana is launched in an I-Frame.
Note You can also view Kibana Logs in a new tab by clicking the View Kibana logs link.
Cross Launching Horizon
Horizon is the canonical implementation of OpenStack's Dashboard, which provides a web based user interface to OpenStack services including Nova, Swift and, Keystone.
Procedure
Step 1 In the Navigation pane, click Post-Install > Horizon .
Step 2 Click the link Click here to view Horizon logs in new tab .
You will be redirected to Horizon landing page in a new tab.
168
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
Managing Blueprints
Monitoring the Pod
NFVI Monitoring
NFVI monitoring is Cross launch same as Horizon. NFVI monitoring link is available in the post install only if the setupdata has NFVI Monitoring configuration during the cloud deployment which basically pings the monitoring and checks status of Collector VM1 Info and Collector VM2 Info .
Procedure
Step 1 In the Navigation pane, click Post-Install > NFVI monitoring .
Step 2 Click the link Click here to view NFVI monitoring.
You will be redirected to NFVI Monitoring page.
Run VMTP
Run VMTP is divided in two sections:
• Results for Auto Run : This will show the results of VMTP which was run during cloud deployment
(Blueprint Installation).
• Results for Manual Run : Here you have an option to run the VMTP on demand. To run VMTP on demand just click Run VMTP button.
Note If VMTP stage was skipped/not-run during Blueprint Installation, this section of POST
Install would be disabled for the user.
Run CloudPulse
Following are the tests supported in CloudPulse:
1 cinder_endpoint
2 glace_endpoint
3 keystone_endpoint
4 nova_endpoint
5 neutron_endpoint
6 rabbitmq_check
7 galera_check
8 ceph_check
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
169
Managing Blueprints
Monitoring the Pod
Run NFV Bench
One can Run NFV Bench for B and C series Pod, through Cisco VIM Insight. On a pod running with CVIM
2.2, click on the NFVbench link on the NAV-Menu.
You can run either fixed rate test or NDR/PDR test. As the settings and results for the test types differ, the options to run these tests are presented in two tabs, with its own settings and results .
NDR/PDR Test
Procedure
Step 1 Log-in to CISCO VIM Insight .
Step 2 In the Navigation pane, click Post-Install >Run NFV Bench.
Step 3 Click on NDR/PDR test and complete the following fields
Name Description
Iteration Duration Select duration from 10 to 60 sec. Default is 20 sec
Frame Size
Run NDR/PDR test
Select the correct frame size to run
Click on Run NDR/PDR test. Once NDR/PDR test is finished it will display each type of test with its own settings and results.
Fixed Rate Test
Procedure
Step 1 Log-in to CISCO VIM Insight .
Step 2 In the Navigation pane, click Post-Install > Run NFV Bench .
Step 3 Click on Fixed rate test and complete the following fields.
Name Description
Rate Rate: Select right configuration pps or bps from drop down-list and enter values :
For pps: minimum: 2500pps; maximum: 14500000pps
(=14.5Mpps); default: 1000000pps (=1Mpps)
For bps: minimum: 1400000bps; maximum:
10000000000bps (=10Gbps); default: 1000000000
(=1Gbps)
170
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
Managing Blueprints
Name
Iteration Duration
Frame Size
Run Fixed rate test
Reconfiguring CIMC Password through Insight
Description
Select duration from 10-60Sec. Default is 20sec.
Select the right frame size(64,IMIX,1518) to run.
Click on Run Fixed rate test. Once Fixed rate test is finished it will display each type of test with its own settings and results.
Reconfiguring CIMC Password through Insight
Update the cimc_password in the CIMC-COMMON section, and/or the individual cimc_password for each server and then run the update password option.
To update a password, you need to follow the password rules:
• Must contain at least one lower case letter.
• Must contain at least one upper case letter.
• Must contain at least one digit between 0 to 9.
• One of these special characters !$#@%^-_+=*&
• Your password has to be 8 to 14 characters long.
Before You Begin
You must have a C-series pod up and running with Cisco VIM to reconfigure CIMC password.
Note Reconfigure CIMC password section would be disabled if the pod is in failed state as indicated by ciscovim install-status.
Procedure
Step 1 Log-in to CISCO VIM Insight .
Step 2 In the navigation pane, select Post-Install
Step 3 Click Reconfigure CIMC Password .
Step 4 On the Reconfigure CIMC Password page of the Cisco VIM Insight, complete the following fields:
Name Description
CIMC_COMMON old Password CIMC_COMMON old password field cannot be edited.
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
171
Reconfiguring CIMC Password through Insight
Name
CIMC-COMMON new Password
Click Update
Managing Blueprints
Description
Enter new CIMC-COMMON password. Password should be alphanumeric according to the password rule.
Old CIMC-COMMON password will be updated with new CIMC-COMMON password.
172
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
C H A P T E R
9
Managing Pod Through Cisco VIM Insight
The following topics tell you how to install and replace Cisco Virtual Infrastructure Manager (VIM) nodes using Cisco VIM Insight.
•
•
•
Pod User Administration, page 195
Managing Hardware
Management of your Cisco VIM pods includes adding, removing, or replacing the nodes.
In a pod, multiple nodes cannot be changed at the same time. For example, if you want to replace two control nodes, you must successfully complete the replacement of the first node before you start to replace the second node. Same restriction applies for addition and removal of storage nodes. Only, in case of Compute Nodes you can add/remove multiple nodes together; however, there must always be one active compute node in the pod at any given point. VNF manager stays active and monitors the compute nodes thereby moving the VNFs accordingly as compute node management happens.
Note When you change a control, storage, or compute node in a Cisco VIM pod using Insight, it will automatically update the server and role in the active blueprint, as a result, your OpenStack deployment will change.
When a node is removed from Cisco VIM, sensitive data may remain on the drives of the server.
Administrator is advices to use Linux tools to wipe the storage server before using the same server for another purpose. The drives used by other application server should also be wiped out before being added to Cisco VIM.
Managing Storage Nodes
Before you add or remove a storage node, review the following guidelines for Managing Storage Nodes.
• Required Number of Storage Nodes : A Cisco VIM pod must have a minimum of three and a maximum of 20 storage nodes. If your pod has only two storage nodes, you cannot delete another storage node
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
173
Managing Pod Through Cisco VIM Insight
Managing Storage Nodes until you add another storage node. If you have fewer than three storage nodes, you can add one node at a time until you get to 20 storage nodes.
• Validation of Nodes : When you add a storage node to a pod, Cisco VIM Insight validates that all the nodes in the pod meet the minimum requirements and are in active state. If you have a control or compute node in a faulty state, you must either correct, delete or replace that node before you can add a storage node.
• Update Blueprint : When you add or delete a storage node, Insight will update the blueprint for the
Cisco VIM pod.
• Storage Node Logs : You can access the logs for each storage node from the link in the Log column on the Storage Nodes tab.
Failed Addition or Deletion of Storage Node : If your attempt to add or delete a storage node fails, complete the following instructions:
Procedure
Step 1 Choose the storage node in the list and click Delete .
Step 2 If the delete fails, click Clear DB Entry to remove the failed node from the database.
If you do not remove the node from the database, you cannot add another node to bring the number of nodes to three.
Adding Storage Node
You cannot add more than one storage node at a time. Complete the following instructions to add a storage node:
Before You Begin
• Remove the non-functional storage node from the pod. You can have maximum 20 storage nodes in a
Cisco VIM pod.
• Ensure that the server for the new storage node is in powered state in OpenStack for C Series.
Procedure
Step 1 In the navigation pane, choose Post-Install > Pod Management .
Step 2 Click the + icon next to Sufficient Pool Present next to Add/Remove Storage Node .
• Sufficient POOL check is automatically filled by Insight.
• It checks the number of IP present in the POOL for Management or Provision.
• If number of nodes is equal to pool size then the option would be disabled and you need to increase the pool size by clicking + icon.
174
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
Managing Pod Through Cisco VIM Insight
Managing Storage Nodes
• Validation check to see if the IP is valid and belongs to the same subnet of the existing IP Pool are applied by insight before you add IPs to Management/Provision network.
Step 3 For C Series, add the following details:
• Server Name : Name for the Storage Server to be added.
• Rack ID : Enter the Rack ID. (Accepts String format).
• CIMC IP : Enter the CIMC IP.
• CIMC User Name : User name for the CIMC.
• CIMC Password : Enter the password for the CIMC
• VIC Slot : Enter the VIC Slot (Optional).
• ToR switch info :Mandatory if ToR is configured as True
◦ Management IPv6 : Enter IPv6 Address.
Step 4 For B Series, add the following details:
• Server Name : Name for the Storage Server to be added.
• Rack ID : Enter the Rack ID. (Accepts String format).
• Rack Unit ID : Enter the Rack Unit ID.
• Management IPv6 : Enter IPv6 Address.
If all mandatory fields are filled in correctly then Add Storage button will be enabled.
Step 5 Click Add Storage . Add node initialized message will be displayed.
Step 6 To view logs, click View logs under Logs column.
The status of the POD will change to Active.
Step 7 Two kinds of failure may occur:
• Add Node Pre-Failed : When addition of node failed before the bare-metal stage (step 4) the Active
Blueprint will be modified but the Node is not yet added in the Cloud. If you press X Icon, then Insight will delete the node information form the Blueprint and the state would be restored.
• Add Node Post-Failed : When addition of node failed after the bare-metal stage (step 4) the Active
Blueprint will be modified and the node is registered in the cloud. If you press X Icon, then Insight will first delete the node from the Blueprint and then node removal from cloud would be initiated.
You can view the logs for this operation under Logs column.
Deleting Storage Node
You cannot delete more than one storage node at a time.
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
175
Managing Pod Through Cisco VIM Insight
Managing Compute Nodes
Procedure
Step 1 In the Navigation pane, choose Post-Install > POD Management .
Step 2 Click X adjacent to the storage node you want to delete.
Step 3 Node Removal Initiated successfully message will be displayed.
To view logs, click View logs under logs column.
• If the Storage Node is deleted successfully, the storage node will be removed from the list under
Add/Remove storage Node .
• In deletion failed, a new button Clear Failed Nodes will be displayed. Click Clear Failed Nodes to remove the node form cloud and Blueprint.
Managing Compute Nodes
Before you add or remove a compute node, review the following guidelines:
• Required Number of Compute Nodes : A Cisco VIM pod must have a minimum of one compute node and a maximum of 96 compute nodes. If your pod has only one compute node, you cannot delete that node until you add another compute node.
• Update Blueprint : When you add or remove a compute node, Insight will update the blueprint for the
Cisco VIM pod.
• Compute Node Logs : You can access the logs for each compute node from the link in the Log column on the Compute Nodes table.
Adding Compute Node
Complete the instructions, to add a compute node:
Before You Begin
Ensure that the server for the new compute node is in powered state in OpenStack. You can add more than one compute node at a time.
Procedure
Step 1 In the navigation pane, click Post-Install > Pod Management .
Step 2 Click + icon next to Sufficient Pool Present adjacent to Add/Remove Compute Node .
• Sufficient POOL check is automatically filled by Insight.
• It checks the number of IP present in the POOL for Management or Provision.
• If number of nodes is equal to pool size then the option would be disabled and you need to increase the pool size by clicking + icon.
176
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
Managing Pod Through Cisco VIM Insight
Managing Compute Nodes
• Validation check to see if the IP is valid and belongs to the same subnet of the existing IP Pool are applied by insight before you add IPs to Management/Provision network.
Step 3 For C Series, add the following details:
• Server Name : Name for the Compute Server.
• Rack ID : Enter the Rack ID. (Accepts String format).
• CIMC IP : Enter the CIMC IP.
• CIMC User Name : User name for the CIMC.
• CIMC Password : Enter the password for the CIMC.
• VIC Slot : Enter the VIC Slot (Optional).
• ToR switch info : Mandatory if configured ToR is true.
• DP ToR switch info : Enter input as string format.
• SRIVO ToR info : Enter input as string format.
• Management IPv6 : Enter IPv6 Address.
Step 4 For B Series, add the following details:
• Server Name : Name for the Storage Server to be added.
• Rack ID : Enter the Rack ID. (Accepts String format).
• Rack Unit ID : Enter the Rack Unit ID.
• Chassis ID : Enter the Chassis ID. Range for Chassis ID is 1-24.
• Blade ID : Enter the Blade ID. Range for Blade ID is 1-8.
• CIMC Password : Enter the CIMC Password.
• Management IPv6 : Enter IPv6 address.
If all mandatory fields are filled in correctly then click Save
Note Add Compute process can initiate multiple add of compute nodes. Fill in the mandatory fields to save new compute node or press cancel to exit message will be displayed.
Fields of Pod management will remain mandatory for user input based on setup-data.
Step 5 You may perform one among these steps mentioned below:
• Clicking Cancel displays the compute node information listed in the table and Add Compute Node button is enabled.
• If you feel you have filled in a wrong entry for the compute node information, click Delete . This will delete the entry from the table as this information is not added in the Blueprint.
• Click Add Compute , displays Add node initialized message.
Step 6 To view logs, click View logs under Logs column. The status of the POD will change to Active.
Step 7 Two kinds of failure may occur:
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
177
Managing Pod Through Cisco VIM Insight
Managing Control Nodes
• Add Node Pre-Failed : When addition of node failed before the bare-metal stage (step 4) the Active
Blueprint will be modified but the Node is not yet added in the Cloud. If you press X Icon, then Insight will delete the node information form the Blueprint and the state would be restored.
• Add Node Post-Failed : When addition of node failed after the bare-metal stage (step 4) the Active
Blueprint will be modified and the node is registered in the cloud. If you press X Icon, then Insight will first delete the node from the Blueprint and then node removal from cloud would be initiated.
You can view the logs for this operation under Logs column.
Deleting Compute Node
Compute node is deleted due to a hardware failure. You can delete one compute node at a time.
Note If your pod has only one compute node, you cannot delete that node until you add another compute node.
Procedure
Step 1 In the navigation pane, choose Post-Install > POD Management .
Step 2 Click X for the compute node to be deleted.
Node Removal Initiated successfully message will be displayed.
Step 3 To view the logs, click View logs under Logs column.
• If compute nodes are deleted successfully, you will not be able to view the compute node in the list under Add/Remove Compute Node .
• If deletion has failed, a new button Clear Failed Nodes will be visible.
Step 4 Click Clear Failed Nodes to remove the node form Cloud and Blueprint.
Managing Control Nodes
Before you replace a control node, review the following guidelines:
• Required Number of Control Nodes : A Cisco VIM pod must have three control nodes and you can only replace one node at a time.
• Validation of Nodes : When you replace a control node, Cisco VIM Insight validates if all the other nodes in the pod meet the minimum requirements and are in active state. If you have a storage or compute node in a faulty state, you must correct the faulty state or delete or replace that node before you can replace the control node.
• Update Blueprint : When you replace a control node, Insight will update the Active blueprint for the
Cisco VIM pod.
178
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
Managing Pod Through Cisco VIM Insight
Managing Software
• Control Node Logs : You can access the logs for each control node from the link in the Logs column of Control Nodes table.
Replacing Control Node
You can replace only one control node at a time.
Procedure
Step 1 In the Navigation pane, click Post-Install > Pod Management .
Step 2 Click Edit/Replace under the Action column of the Replace Control table.
Step 3 On success, Replace Node Initiated successfully message will be displayed.
Step 4 You can view the logs in the Logs column on the Control Nodes table.
What to Do Next
If the replacement of the control node fails, do the following:
• Click on the link in the Logs column.
• Check the logs to determine the cause of the failure.
• Correct the issue and attempt to replace the control node again.
Managing Software
Software management of your Cisco VIM pods includes software update, reconfigure of openstack services and password, etc.
VIM Software Update
As part of the lifecycle management of the cloud, VIM has the ability to bring in patches (bug fixes related to code, security, etc.), thereby providing cloud management facility from software point of view. Software update of the cloud is achieved by uploading a valid tar file, following initiation of a System Update form the
Insight as follows:
Procedure
Step 1 In the Navigation pane, click Post-Install > System Update .
Step 2 Click Browse and select the valid tar file.
Step 3 Click Open .
Step 4 Click Upload and Update .
Update started Successfully message will be displayed.
Step 5 Update status will be shown as ToUpdate .
Click the hyperlink to view the reconfigure logs for install logs.
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
179
Managing Pod Through Cisco VIM Insight
Reconfiguring CIMC Password
Reconfigure status will be available on the page or the dashboard under POD Operation details.
What to Do Next
System Update has been initiated message will be displayed. Logs front-ended by hyperlink will be in the section below in-front of Update Logs which shows the progress of the update. During the software update, all other pod management activities will be disabled. Post-update, normal cloud management will commence.
Once update has completed you will see the status of update in the box below.
If log update fails, Auto-RollBack will be initiated automatically.
If log update is Successful, you will have two options to be performed:
1 Commit — To proceed with the update.
2 RollBack — To cancel the update.
If Auto-rollback fails during software update fails through Insight UI, it is advised that the administrator contact Cisco TAC for help. Do not re-try the update or delete the new or the old installer workspace.
Reconfiguring CIMC Password
Cisco VIM Insight offers to reconfigure CIMC Password only for C Series Management Node. In case of B
Series Management node the navigation menu to reconfigure the CIMC Password link will not be visible.
You need to match the following Password rule to run Reconfigure of CIMC Password:
• Must contain at least one lower case letter.
• Must contain at least one upper case letter.
• Must contain at least one digit between 0 to 9.
• One of these special characters !$#@%^-_+=*&
• Your password has to be 8 to 14 characters long.
Procedure
Step 1 Log-in to CISCO VIM Insight .
Step 2 In the navigation pane, select Post-Install .
Step 3 Click Reconfigure CIMC Password .
Step 4 You can reconfigure the CIMC Password at global level by adding new CIMC_COMMON Password or to reconfigure CIMC Password for individual servers double click the server password you want to edit.
Step 5 Click Reconfigure to initiate reconfigure process.
180
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
Managing Pod Through Cisco VIM Insight
Reconfigure Password
Reconfigure Password
• Regenerate all passwords : Click Regenerate all passwords checkbox and click Set Password . This will automatically regenerate all passwords in alphanumeric format.
• Regenerate single or more password : This will set a specific password by doing an inline edit for any service like Horizon's ADMIN_USER_PASSWORD. Double click on the filed under Password and enter the password to enable Set Password button.
During the reconfiguration of password, all other pod management activities will be disabled. Post-update, normal cloud management will commence. If the reconfigure of the password fails, all subsequent pod management operations will be blocked. It is advised to contact Cisco TAC to resolve the situation through
CLI.
Reconfigure OpenStack Services, TLS Certificates and ELK Configurations
Cisco VIM supports the reconfiguration of OpenStack log level services, TLS certificates, and ELK configuration. Listed below are the steps to reconfigure the OpenStack and other services:
Procedure
Step 1 In the Navigation pane, click Post-Install > Reconfigure Openstack Config .
Step 2 Click on the specific item that you want to change and update. For example: to update TLS certificate click the path to certificate location.
Step 3 Enter Set Config to commence the process.
What to Do Next
During the reconfiguration process, all other pod management activities will be disabled. Post-update, normal cloud management will commence. If reconfigure of OpenStack Services fail, all subsequent pod management operations will be blocked. It is advised to contact Cisco TAC to resolve the situation through CLI.
Reconfiguring CIMC Password
Cisco VIM Insight offers to reconfigure CIMC Password only for C Series Management Node. In case of B
Series Management node the navigation menu to reconfigure the CIMC Password link will not be visible.
You need to match the following Password rule to run Reconfigure of CIMC Password:
• Must contain at least one lower case letter.
• Must contain at least one upper case letter.
• Must contain at least one digit between 0 to 9.
• One of these special characters !$#@%^-_+=*&
• Your password has to be 8 to 14 characters long.
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
181
Managing Pod Through Cisco VIM Insight
Reconfigure Optional Services
Procedure
Step 1 Log-in to CISCO VIM Insight .
Step 2 In the navigation pane, select Post-Install .
Step 3 Click Reconfigure CIMC Password .
Step 4 You can reconfigure the CIMC Password at global level by adding new CIMC_COMMON Password or to reconfigure CIMC Password for individual servers double click the server password you want to edit.
Step 5 Click Reconfigure to initiate reconfigure process.
Reconfigure Optional Services
Cisco VIM offers optional services such as heat, migration to Keystone v3, NFVBench, NFVIMON, etc, that can be enabled post-pod deployment. These services can be enabled in one-shot or selectively.
Listed below are the steps to enable optional services:
Procedure
Step 1 In the Navigation pane, click Post-Install > Reconfigure Optional Services .
Step 2 Choose the right services and update the fields with the right values.
Step 3 Click Offline validation . Once offline validation is successful.
Step 4 Click Reconfigure to commence the process.
During the reconfiguration process, all other pod management activities will be disabled. Post-update, normal cloud management will commence.
If reconfigured OpenStack Services fail, all subsequent pod management operations will be blocked. It is advised to contact Cisco TAC to resolve the situation through CLI.
Note All reconfigure operation feature contains repeated deployment true or false.
• Repeated re-deployment true - Feature can be re-deployed again.
• Repeated re-deployment false- Deployment of feature allowed only once.
Deployment Status :
Optional Features
APICINFO
EXTERNAL_LB_VIP_FQDN
True
False
False EXTERNAL_LB_VIP_TLS
INSTALL_MODE True
182
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
Managing Pod Through Cisco VIM Insight
Optional Features
LDAP
NETWORKING
NFVBENCH
NFVIMON
PODNAME
PROVIDER_VLAN_RANGES
SWIFTSTACK
SYSLOG_EXPORT_SETTINGS
TENANT_VLAN_RANGES
TORSWITCHINFO
VIM _ ADMINS
VMTP
VTS_PARAMETERS
AUTOBACKUP
Heat
Keystone v3
True
False
False
`
True
False
False
True
False
True
False
True
True
False
False
False
True
Reconfigure Optional Services
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
183
Managing Pod Through Cisco VIM Insight
Reconfiguring Optional Features through Insight
Reconfiguring Optional Features through Insight
Procedure
Step 1 Log-in to Cisco VIM Insight.
Step 2 In the Navigation pane, expand the Post-Install Section .
Step 3 Click Reconfiguring Optional Feature through Insight .
Step 4 On the Reconfiguring Optional Feature through Insight page of the Cisco VIM Insight, complete the following fields:
Name Description
Heat checkbox
• Enable Heat .
• Click Offline Validation .
• Once Offline Validation is successful, click
Reconfigure to commence the process..
Keystone v3 checkbox
• Enable Keystone v3 .
• Click Offline Validation .
• Once Offline Validation is successful, click
Reconfigure to commence the process.
Autobackup checkbox
• Enable/Disable Autobackup .
• Click Offline Validation .
• Once Offline Validation is successful, click
Reconfigure to commence the process.
External LB VIP TLS checkbox
• Enable External LB VIP TLS .
• Click Offline Validation .
• Once Offline Validation is successful, click
Reconfigure to commence the process.
External LB VIP FQDN checkbox
• Enter Input as string.
• Click Offline Validation .
• Once Offline Validation is successful, click
Reconfigure to commence the process.
184
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
Managing Pod Through Cisco VIM Insight
Name
Pod Name
Tenant Vlan Ranges
Provider Vlan Ranges
Install Mode
Reconfiguring Optional Features through Insight
Description
• Enter Input as string.
• Click Offline Validation .
• Once Offline Validation is successful, click
Reconfigure to commence the process.
• Augment tenant vlan ranges input eg.
3310:3315.
• Click Offline Validation .
• Once Offline Validation is successful, click
Reconfigure to commence the process.
• Enter input to tenant vlan ranges eg. 3310:3315.
• Click Offline Validation .
• Once Offline Validation is successful, click
Reconfigure to commence the process.
• Select Connected or Disconnected , any one form the drop-down list.
• Click Offline Validation .
• Once Offline Validation is successful, click
Reconfigure to commence the process.
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
185
Reconfiguring Optional Features through Insight
Name
Skylog Export Settings
Configure ToR checkbox
Managing Pod Through Cisco VIM Insight
Description
Following are the options for Skylog Settings:
Remote Host Enter Syslog IP Address.
Facility Defaults to local5
Severity
Clients
Port
Protocol
Defaults to debug
Defaults to ELK
Defaults to 514 but can be modified by the User.
Supports only UDP
• Click Offline Validation .
• Once Offline Validation is successful, click
Reconfigure to commence the process.
True or False . Default is false.
186
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
Managing Pod Through Cisco VIM Insight
Reconfiguring Optional Features through Insight
Name
ToR Switch Information
Description
Click + to add information for ToR Switch.
Name
Name
Description
ToR switch name.
Username
Password
ToR switch username.
ToR switch Password.
SSH IP
SSN Num
VPC Peer Keepalive
VPC Domain
VPC Peer port
ToR switch SSH IP
Address.
ToR switch ssn num.
output of show license host-id.
Peer Management IP.
You need not define if there is no peer.
Need not define if there is no peer.
Interface for vpc peer ports.
VPC Peer VLAN Info vlan ids for vpc peer ports (optional).
BR Management Port
Info
Management interface of build node.
BR Management PO
Info
Port channel number for management interface of build node.
Click Save
• Click Offline Validation .
• Once Offline Validation is successful, click
Reconfigure to commence the process.
Note
:
When setup data is ACI VLAN with TOR then reconfigure options are
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
187
Managing Pod Through Cisco VIM Insight
Reconfiguring Optional Features through Insight
TORSwitch Information mandatory table if you want to enter ToR information
Click + to add information for ToR Switch.
Name
Host Name
Description
ToR switch name.
VPC Peer Keepalive
VPC Domain
Node ID
Peer Management IP. Do not define if there is no
Do not define if there is no
Integer, unique across all switches
NFV Bench
Click Save
• Click Offline Validation .
• Once Offline Validation is successful, click
Reconfigure to commence the process.
Enable checkbox which by default is false.
Add Tor info connected to switch:
• Select a TOR Switch and Enter the Switch name.
• Enter the port number. For example: eth1/5
• NIC Ports: INT1 and INT2 optional input, enter the 2 port numbers of the 4-port 10G Intel NIC at the management node used for NFVBench.
Note
• Click Offline Validation .
• Once Offline Validation is successful, click
Reconfigure to commence the process.
If ToR is already present in Setup-data or already deployed. Then no need add Tor info, by default ToR info switchname will be mapped in NFV bench.
188
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
Managing Pod Through Cisco VIM Insight
Reconfiguring Optional Features through Insight
Swiftstack
SwiftStack is only supported with Keystone v2. If you select Keystone v3, swiftstack will not be available for configuration.
Cluster End Point
Admin User
Admin Tenant
Reseller Prefix
IP address of PAC
(proxy-account-container) endpoint.
Admin user for swift to authenticate in keystone.
The service tenant corresponding to the
Account-Container used by Swiftstack.
Reseller_prefix as configured for Keysone
Auth,AuthToken support in Swiftstack E.g KEY_
Admin Password swiftstack_admin_password
Protocol drop-down list http or https
• Click Offline Validation .
• Once Offline Validation is successful, click
Reconfigure to commence the process.
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
189
Reconfiguring Optional Features through Insight
LDAP with Keystone v3
Managing Pod Through Cisco VIM Insight
Domain Name field Enter name for Domain name.
Object Class for Users field
Enter a string as input.
Object Class for
Groups
Enter a string.
Domain Name Tree for
Users
Enter a string.
Domain Name Tree for
Groups field
Enter a string.
Suffix for Domain
Name field
Enter a string.
URL field Enter a URL with ending port number.
Domain Name for Bind
User field
Enter a string.
Password field
User Filter
Enter Password as string format.
Enter filter name as string.
User ID Attribute
User Name Attribute
Enter a string.
Enter a string.
User Mail Attribute Enter a string.
Group Name Attribute Enter a string.
• Click Offline Validation .
• Once Offline Validation is successful, click
Reconfigure to commence the process.
190
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
Managing Pod Through Cisco VIM Insight
NFV Monitoring
Reconfiguring Optional Features through Insight
Followings are the field values for NFV Monitoring:
Master Admin IP field.
Enter Input as IP format.
Collector Management
IP field
Enter Input as IP format.
Collector VM1 info
Host Name field Enter Host Name as string.
Enter Password.
CCUSER password field
Password field Enter password.
Admin IP field
Management IP field
Enter Input as IP format.
Enter Input as IP format.
Collector VM2 info
Host Name field Enter a string.
CCUSER field
Management IP field
Enter Password.
Enter Input as IP format.
Dispatcher
Rabbit MQ Username
Field
Enter a string.
• Click Offline Validation .
• Once Offline Validation is successful, click
Reconfigure to commence the process.
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
191
Reconfiguring Optional Features through Insight
VTS Parameter
Managing Pod Through Cisco VIM Insight
Following are the fields to reconfigure for VTS parameters
VTC SSH Username field.
Enter the string.
VTC SSH Username field.
Enter the password.
• Click Offline Validation .
• Once Offline Validation is successful, click
Reconfigure to commence the process.
192
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
Managing Pod Through Cisco VIM Insight
VMTP
Reconfiguring Optional Features through Insight
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
193
Reconfiguring Optional Features through Insight
194
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
Managing Pod Through Cisco VIM Insight
Check one of the check boxes to specify a VMTP network:
• Provider Network
• External Network
For the Provider Network complete the following:
Network Name field.
Enter the name for the external network.
IP Start field.
Enter the starting floating IPv4 address.
IP End field.
Gateway field
Enter the ending floating
IPv4 address.
Enter the IPv4 address for the Gateway.
DNS Server field.
Enter the DNS server
IPv4 address.
Segmentation ID field.
Enter the segmentation
ID.
Subnet Enter the Subnet for
Provider Network.
For External Network fill in the following details:
Network Name field.
Enter the name for the external network.
Network IP Start field.
Enter the starting floating IPv4 address.
Network IP End field.
Enter the ending floating
IPv4 address.
Network Gateway field Enter the IPv4 address for the Gateway.
DNS Server field.
Subnet
Enter the DNS server
IPv4 address.
Enter the Subnet for
Managing Pod Through Cisco VIM Insight
Pod User Administration
External Network.
• Click Offline Validation .
• Once Offline Validation is successful, click
Reconfigure to commence the process.
Networking
IP Tables
Note In Reconfigure optional services networking you can reconfigure IP tables.
To reconfigure IP tables following are the process you need follow.
• Click on Add(+) to add table.Enter input as subnet format. Eg. 12.1.0.1/2
• Click on Save.
• Click on Offline Validation.
• Once Offline Validation success hits on
Reconfigure. Reconfigure Operation would be initiated.
APICINFO
Note Reconfigure optional services only APIC hosts can be reconfigure.
To reconfigure APICINFO following are the process you need to follow
• Enter input for APIC hosts format.
<ip1|host1>:[port] or eg.12.1.0.12
• Click on Save.
• Click on Offline Validation.
• Once Offline Validation success hits on
Reconfigure. Reconfigure Operation would be initiated.
Note APIC hosts can be reconfigure minimum 1 host and max 3 but not 2 hosts.
Pod User Administration
Cisco VIM Insight offers Users (Pod Admin(s) or Pod Users) to manage Users and roles associated with them.
Managing Roles
To create a new Role
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
195
Managing Pod Through Cisco VIM Insight
Managing Users
Procedure
Step 1 Click Login as POD User.
Step 2 Navigate to Pod User Administration and click Manage Roles . By default you will see full-pod-access role in the table.
Step 3 Click Add New Role to create a new role.
Step 4 Complete the following fields in the Add Roles page in Cisco VIM Insight:
Field Name Field Description
Role Enter the name of the role.
Description
Permission
Click Save .
Enter the description of the role.
Check the Permission checkbox to select the permission.
Once the Blueprint is in Active state all the permissions are same for C-series and B-series PODs other than Reconfigure CIMC Password which is missing for B-series POD.
Note Permissions are divided in granular level where viewing Dashboard is the default role that is implicitly added while creating a role.
Managing Users
To add new User
Procedure
Step 1 Click Login as POD User .
Step 2 Navigate to POD User Administration .
Step 3 Click Manage Users .
Step 4 Click Add Users to add a new user.
Step 5 Complete the following fields in the Add Users page of the Cisco VIM Insight:
Field Name Field Description
Email ID Enter the Email ID of the User.
User Name Enter the User Name if the User is new. If the User is already registered to the Insight the
User-Name gets auto-populated.
196
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
Managing Pod Through Cisco VIM Insight
Managing Root CA Certificate
Field Name
Role
Field Description
Select the Role from the drop-down list.
Step 6 Click Save .
Managing Root CA Certificate
You can update the CA Certificate during the registration of the POD. Once, logged in as POD User and if you have the permission to update the certificate you can view under POD User Administration>> Manage
Root CA Certificate.
To update the Certificate:
Procedure
Step 1 Click Login as POD User
Step 2 Navigate to POD User Administration>>Manage Root CA certificate .
Step 3 Click Browse and select the certificate that you want to upload.
Step 4 Click Upload.
• If the certificate is Invalid, and does not matches with the certificate on the management node located at (var/www/mercury/mercury-ca.crt) then Insight will revert the certificate which was working previously.
• If the Certificate is valid, Insight will run a management node health check and then update the certificate with the latest one.
Note The CA Certificate which is uploaded should be same as the one which is in the management node.
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
197
Managing Root CA Certificate
Managing Pod Through Cisco VIM Insight
198
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
C H A P T E R
10
Day 2 Operations of Cisco VIM Insight
The following topic guides you the details about the Day 2 Operations of Cisco VIM Insight.
•
Shutting Down Cisco VIM Insight, page 199
•
Restarting Cisco VIM Insight, page 200
•
Restoring VIM Insight, page 200
•
Reconfiguring VIM Insight , page 202
Shutting Down Cisco VIM Insight
To stop the Cisco VIM Insight Container services, shut down Cisco UCS VIM Insight by running the systemctl stop service command.
Procedure
Step 1 Log in to a server in which the Insight container is running.
Step 2 Stop the Insight service by running the following command from the Shell window: systemctl stop docker-insight a) Check the status of Insight Container by running the following command: docker ps -a | grep insight.
STATUS
Up 6 seconds b) Check the status of the service by running the following command: systemctl staus docker-insight
The following information is displayed
Docker-insight.service
– Insight Docker Service
Loaded: loaded (/usr/lib/systemd/system/docker-insight.service; enabled; vendor preset: disabled)
Active: inactive (dead) since <Date and Time since it was last active>
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
199
Day 2 Operations of Cisco VIM Insight
Restarting Cisco VIM Insight
Restarting Cisco VIM Insight
Procedure
Step 1 Log in to the server in which the Insight container was stopped.
Step 2 Restart the Insight service by running the following command from the shell window: systemctl restart docker-insight a) Check the status of Insight container by running the following command: docker ps -a | grep insight.
STATUS
Up 6 seconds b) Check the status of the service by running the following command: systemctl status docker-insight
The following output is displayed:
Docker-insight.service
– Insight Docker Service
Loaded: loaded (/usr/lib/systemd/system/docker-insight.service; enabled; vendor preset: disabled)
Active: active (running) since <Date and Time when it got active.>
Restoring VIM Insight
Cisco VIM Insight can be restored to its previous running state which existed at the time of backup.
Note Insight should not be running on the node on which restore operation will be performed
Procedure
Step 1 Re-image the Insight management node with the ISO version with which you want to restore the node, and with the same IP address that is used before the failure of the node.
Note NOTE: Skip Step 1 if re-image already done with the ISO during management node restore. Insight restore can also be performed without re-image with ISO . Uninstall the Insight through bootstrap_insight.py and then restoring it by following below mentioned steps but this needs to be only done when you face issues with Insight and not in case of management node failure.
Step 2 Navigate to /var/cisco/insight_backup/ directory at the remote server where the backup directory was copied during the backup operation.
Step 3 Copy the backup file to the /var/cisco/insight_backup/ directory of the re-imaged management node. For example, to copy the backup directory from the remote host 20.0.0.5 to the management node
200
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
Day 2 Operations of Cisco VIM Insight
Restoring VIM Insight
/var/cisco/insight_backup/directory, execute the following command sequence: rsync -e ssh -rtvpX --numeric-ids [email protected]:/var/cisco/insight_backup/backup_2017-01-09_14-04-38 /var/cisco/insight_backup.
Step 4 In /var/cisco/insight_backup/backup_<date-time> directory, execute the following command:
# ./insight_restore – h insight_restore : Cisco VIM Insight Restore Script
----------------------------------------------------
Usage: ./insight_restore
-v
-h
: Enable verbose mode
: To display this help message
# ./insight_restore
This will initiate an Insight install with the backed up data.
VIM Insight restore logs are at: /var/log/insight/<bootstrap_insight_<date>_<time>.log
Management Node Validations!
+-------------------------------+--------+-------+
| Rule | Status | Error |
+-------------------------------+--------+-------+
| Check Kernel Version | PASS | None |
| Check Docker Version | PASS | None |
| Check Management Node Tag | PASS | None |
| Check Bond Intf. Settings | PASS | None |
| Root Password Check | PASS | None |
| Check Boot Partition Settings | PASS | None |
| Check LV Swap Settings | PASS | None |
| Check Docker Pool Settings | PASS | None |
| Check Home Dir Partition | PASS | None |
| Check Root Dir Partition | PASS | None |
| Check /var Partition | PASS | None |
| Check LVM partition | PASS | None |
| Check RHEL Pkgs Install State | PASS | None |
+-------------------------------+--------+-------+
Insight standalone Input Validations!
+-------------------------------------------+--------+-------+
| Rule | Status | Error |
+-------------------------------------------+--------+-------+
| Insight standalone Schema Validation
| Valid Key Check in Insight Setup Data |
| PASS | None |
PASS | None |
| Duplicate Key Check In Insight Setup Data | PASS | None |
+-------------------------------------------+--------+-------+
Setting up Insight, Kindly wait!!!
Cisco VIM Insight Installed successfully!
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
201
Day 2 Operations of Cisco VIM Insight
Reconfiguring VIM Insight
+-----------------------+--------+---------------------------------------------------------+
| Description | Status | Details
|
+-----------------------+--------+---------------------------------------------------------+
| VIM Insight UI URL
|
| PASS | https://<br_api:9000>
| VIM UI Admin Email ID | PASS | Check for info @: <abs path of insight_setup_data.yaml>
|
| | | |
| VIM UI Admin Password | PASS | Check for info @ /opt/cisco/insight/secrets.yaml
|
| VIM Insight Workspace | PASS | /root/<insight_ws>
|
+-------------------+-------+------------------------------------------------+
VIM Insight restore successfully completed!
Done with VIM Insight restore!
VIM Insight restore logs are at: /var/log/insight/bootstrap_insight/
As the summary table describes, your VIM Insight workspace is restored and hence you need to use bootstrap_insight.py from the mentioned workspace for performing any actions from here on.
Step 5 Verify Insight status after restore operation.
# cd /root/<insight_ws>
# ./bootstrap_insight.py
– a install-status
Cisco VIM Insight Install Status!
+-----------------------+--------+----------------------------------+
| Description | Status | Details |
+-----------------------+--------+----------------------------------+
| VIM Insight Version | PASS | <release_tag>
| VIM Insight UI URL | PASS | https://<br_api:9000>
|
| VIM Insight Container | PASS | insight_<tag_id>
| VIM Mariadb Container | PASS | mariadb_<tag_id>
| VIM Insight Workspace | PASS | /root/<insight_ws> |
+-----------------------+--------+----------------------------------+
|
|
|
Reconfiguring VIM Insight
Insight reconfigure action provides you with three major functionalities:
1 Reconfigure Insight TLS Certificate.
2 Switch from Self Signed TLS Certificate to 3 rd
Party TLS Certificate.
3 Reconfigure Insight MySQL Database Password.
202
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
Day 2 Operations of Cisco VIM Insight
Reconfiguring Insight TLS Certificate
Note Insight reconfigure is not allowed after an update, as update is an intermediate stage between rollback and commit.
Reconfiguring Insight TLS Certificate
As the Insight web-service is protected by TLS, hence reconfigure action provides flexibility to change the existing TLS Certificate. As there were two approaches to configure it, there are also two approaches to change it.
Reconfigure 3
rd
Party TLS Certificate
If you had provided your own TLS Certificate before Insight Installation through PEM_PATH key in insight_setup_data.yaml, then follow the below mentioned steps to reconfigure it.
Procedure
Step 1 To reconfigure the 3rd Party TLS certification run the following command:
# cd <path insight_setup_data.yaml>
Step 2 Open insight_setup_data.yaml file.
# vi insight_setup_data.yaml
Step 3 Edit the insight_setup_data.yaml to change value of PEM_PATH key to point to path of your new valid TLS
Certificate. Save the file after editing. For example: PEM_PATH: "/root/new_tls.pem"
Note Only change in value of PEM_PATH key is allowed during reconfigure. Any change detected in insight_setup_data.yaml other than PEM_PATH value will result in failure of Insight reconfigure.
Step 4 Run the bootstrap command as follows:
# cd <insight_ws>
# ./bootstrap_insight.py
– a reconfigure – f <path_to insight_setup_data.yaml>
VIM Insight reconfigure logs are at: /var/log/insight/<bootstrap_insight_<date>_<time>.log
Perform the action. Continue (Y/N)y
Management Node Validations!
+-------------------------------+--------+-------+
| Rule | Status | Error |
+-------------------------------+--------+-------+
| Check Kernel Version | PASS | None |
| Check Docker Version | PASS | None |
| Check Management Node Tag | PASS | None |
| Check Bond Intf. Settings | PASS | None |
| Root Password Check | PASS | None |
| Check Boot Partition Settings | PASS | None |
| Check LV Swap Settings | PASS | None |
| Check Docker Pool Settings | PASS | None |
| Check Home Dir Partition | PASS | None |
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
203
Day 2 Operations of Cisco VIM Insight
Reconfiguring Insight TLS Certificate
| Check Root Dir Partition | PASS | None |
| Check /var Partition | PASS | None |
| Check LVM partition | PASS | None |
| Check RHEL Pkgs Install State | PASS | None |
+-------------------------------+--------+-------+
Insight standalone Input Validations!
+-------------------------------------------+--------+-------+
| Rule | Status | Error |
+-------------------------------------------+--------+-------+
| Insight standalone Schema Validation
| Valid Key Check in Insight Setup Data
| PASS | None |
| PASS | None |
| Duplicate Key Check In Insight Setup Data | PASS | None |
| Config Change Check in Insight Setup Data | PASS | None |
+-------------------------------------------+--------+-------+
WARNING!! reconfigure will have few secs of Outage for Insight!
Cisco VIM Insight Already Exists!
+-----------------------+--------+---------------------------------------------------------+
| Description
|
| Status | Details
+-----------------------+--------+---------------------------------------------------------+
| VIM Insight UI URL
|
| PASS | https://<br_api:9000>
| VIM UI Admin Email ID | PASS | Check for info @: <abs path of insight_setup_data.yaml>
|
| | | |
| VIM UI Admin Password | PASS | Check for info @ /opt/cisco/insight/secrets.yaml
|
| VIM Insight Workspace | PASS | /root/<insight_ws>
|
+-----------------------+--------+---------------------------------------------------------+
Cisco VIM Insight backup Info!
+-----------------------+--------+--------------------------------------------------------------+
| Description | Status | Details
|
+-----------------------+--------+--------------------------------------------------------------+
| Insight backup Status | PASS | Backup done @
|
| | | /var/cisco/insight_backup/backup-<release_tag>-<date_time>
|
+-----------------------+--------+--------------------------------------------------------------+
Done with VIM Insight reconfigure!
VIM Insight reconfigure logs are at: "/var/log/insight/bootstrap_insight/"
As the summary table describes Insight gets autobacked up after reconfigure at
/var/cisco/insight_backup to preserve the latest state of Insight.
204
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
Day 2 Operations of Cisco VIM Insight
Reconfiguring Insight TLS Certificate
Reconfigure Self Signed TLS Certificate
If you had created a new TLS Certificate through tls_insight_cert_gen.py before Insight Installation then follow the below mentioned steps to reconfigure it.
Procedure
Step 1 Run the following commands to reconfigure the self signed TLS certificate:
# cd <insight_ws>
# ./tls_insight_cert_gen.py
– h usage: tls_insight_cert_gen.py [-h] [--overwrite] --file INSIGHTSETUPDATA
TLS cert generator Insight optional arguments:
-h, --help
--overwrite, -o config directory show this help message and exit
Overwrite Insight certificates if already present in openstack
--file INSIGHTSETUPDATA, -f INSIGHTSETUPDATA
Location of insight_setup_data.yaml
# ./tls_insight_cert_gen.py
– f <path insight_setup_data.yaml> --overwrite
This will overwrite the existing TLS certificate.
Management Node Validations!
+-------------------------------+--------+-------+
| Rule | Status | Error |
+-------------------------------+--------+-------+
| Check Kernel Version | PASS | None |
| Check Ansible Version | PASS | None |
| Check Docker Version | PASS | None |
| Check Management Node Tag | PASS | None |
| Check Bond Intf. Settings | PASS | None |
| Root Password Check | PASS | None |
| Check Boot Partition Settings | PASS | None |
| Check LV Swap Settings | PASS | None |
| Check Docker Pool Settings | PASS | None |
| Check Home Dir Partition | PASS | None |
| Check Root Dir Partition | PASS | None |
| Check /var Partition | PASS | None |
| Check LVM partition | PASS | None |
| Check RHEL Pkgs Install State | PASS | None |
+-------------------------------+--------+-------+
Insight standalone Input Validations!
+-------------------------------------------+--------+-------+
| Rule | Status | Error |
+-------------------------------------------+--------+-------+
| Insight standalone Schema Validation
| Valid Key Check in Insight Setup Data
| PASS | None |
| PASS | None |
| Duplicate Key Check In Insight Setup Data | PASS | None |
| Test Email Server for Insight | PASS | None |
+-------------------------------------------+--------+-------+
Generating a 4096 bit RSA private key
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
205
Day 2 Operations of Cisco VIM Insight
Reconfiguring Insight TLS Certificate
.....................................................................................++
.......++ writing new private key to '../openstack-configs/insight.key'
Step 2 Following are the steps to run the bootstrap:
# ./bootstrap_insight.py
– a reconfigure – f <path_to insight_setup_data.yaml>
VIM Insight reconfigure logs are at: /var/log/insight/<bootstrap_insight_<date>_<time>.log
Perform the action. Continue (Y/N)y
Management Node Validations!
+-------------------------------+--------+-------+
| Rule | Status | Error |
+-------------------------------+--------+-------+
| Check Kernel Version | PASS | None |
| Check Ansible Version | PASS | None |
| Check Docker Version | PASS | None |
| Check Management Node Tag | PASS | None |
| Check Bond Intf. Settings | PASS | None |
| Root Password Check | PASS | None |
| Check Boot Partition Settings | PASS | None |
| Check LV Swap Settings | PASS | None |
| Check Docker Pool Settings | PASS | None |
| Check Home Dir Partition | PASS | None |
| Check Root Dir Partition | PASS | None |
| Check /var Partition | PASS | None |
| Check LVM partition | PASS | None |
| Check RHEL Pkgs Install State | PASS | None |
+-------------------------------+--------+-------+
Insight standalone Input Validations!
+-------------------------------------------+--------+-------+
| Rule | Status | Error |
+-------------------------------------------+--------+-------+
| Insight standalone Schema Validation | PASS | None |
| Valid Key Check in Insight Setup Data | PASS | None |
| Duplicate Key Check In Insight Setup Data | PASS | None |
| Config Change Check in Insight Setup Data | PASS | None |
| Test Email Server for Insight | PASS | None |
+-------------------------------------------+--------+-------+
WARNING!! reconfigure will have few secs of Outage for Insight
Cisco VIM Insight Already Exists!
+-----------------------+--------+---------------------------------------------------------+
| Description | Status | Details
|
+-----------------------+--------+---------------------------------------------------------+
| VIM Insight UI URL
|
| PASS | https://<br_api:9000>
| VIM UI Admin Email ID | PASS | Check for info @: <abs path of insight_setup_data.yaml>
|
| | | |
| VIM UI Admin Password | PASS | Check for info @ /opt/cisco/insight/secrets.yaml
|
| VIM Insight Workspace | PASS | /root/<insight_ws>
206
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
Day 2 Operations of Cisco VIM Insight
Reconfiguring Insight TLS Certificate
|
+-----------------------+--------+---------------------------------------------------------+
Cisco VIM Insight backup Info!
+----------------------+-------+-------------------------------------------------------------------+
| Description | Status| Details
|
+----------------------+-------+-------------------------------------------------------------------+
| Insight backup Status| PASS | Backup done @
|
| | |
/var/cisco/insight_backup/insight_backup_<release_tag>_<date_time>|
+----------------------+-------+-------------------------------------------------------------------+
Done with VIM Insight reconfigure!
VIM Insight reconfigure logs are at: "/var/log/insight/bootstrap_insight/"
As the summary table describes Insight gets autobacked up after reconfigure at
/var/cisco/insight_backup to preserve the latest state of Insight.
Switch from Self Signed TLS Certificate to 3
rd
Party TLS Certificate
If you had created a new TLS Certificate via tls_insight_cert_gen.py before Insight Installation and now want to switch to your own TLS Certificate then follow the below mentioned steps.
Note You cannot switch from 3 rd
Party TLS Certificate to Self Signed TLS Certificate.
Procedure
Step 1 To switch from self signed TLS Certificate to 3rd party TLS certificate open and edit the insight_setup_data.yaml to add PEM_PATH by running the following command:
# cd <path insight_setup_data.yaml>
# vi insight_setup_data.yaml
Edit the insight_setup_data.yaml to add PEM_PATH key to point to path of your new valid TLS
Certificate. Save the file after editing.
For example:
PEM_PATH: “ /root/new_tls.pem
”
Note Only addition of PEM_PATH key is allowed during reconfigure. Any change detected in insight_setup_data.yaml other than PEM_PATH value will result in failure of Insight reconfigure.
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
207
Day 2 Operations of Cisco VIM Insight
Reconfiguring Insight TLS Certificate
Step 2 Following is the command to run the bootstrap:
# cd <insight_ws>
# ./bootstrap_insight.py
– a reconfigure – f <path_to insight_setup_data.yaml>
VIM Insight reconfigure logs are at: /var/log/insight/<bootstrap_insight_<date>_<time>.log
Perform the action. Continue (Y/N)y
Management Node Validations!
+-------------------------------+--------+-------+
| Rule | Status | Error |
+-------------------------------+--------+-------+
| Check Kernel Version | PASS | None |
| Check Ansible Version | PASS | None |
| Check Docker Version | PASS | None |
| Check Management Node Tag | PASS | None |
| Check Bond Intf. Settings | PASS | None |
| Root Password Check | PASS | None |
| Check Boot Partition Settings | PASS | None |
| Check LV Swap Settings | PASS | None |
| Check Docker Pool Settings | PASS | None |
| Check Home Dir Partition | PASS | None |
| Check Root Dir Partition | PASS | None |
| Check /var Partition | PASS | None |
| Check LVM partition | PASS | None |
| Check RHEL Pkgs Install State | PASS | None |
+-------------------------------+--------+-------
Insight standalone Input Validations!
+-------------------------------------------+--------+-------+
| Rule | Status | Error |
+-------------------------------------------+--------+-------+
| Insight standalone Schema Validation | PASS | None |
| Valid Key Check in Insight Setup Data | PASS | None |
| Duplicate Key Check In Insight Setup Data | PASS | None |
| Config Change Check in Insight Setup Data | PASS | None |
| Test Email Server for Insight | PASS | None |
+-------------------------------------------+--------+-------+
WARNING!! reconfigure will have few secs of Outage for Insight!
Cisco VIM Insight Already Exists!
+-----------------------+--------+---------------------------------------------------------+
| Description
|
| Status | Details
+-----------------------+--------+---------------------------------------------------------+
| VIM Insight UI URL | PASS | https://<br_api:9000>
|
| VIM UI Admin Email ID | PASS | Check for info @: <abs path of insight_setup_data.yaml>
|
|
| | |
| VIM UI Admin Password | PASS | Check for info @ /opt/cisco/insight/secrets.yaml
|
| VIM Insight Workspace | PASS | /root/<insight_ws>
|
208
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
Day 2 Operations of Cisco VIM Insight
Reconfiguring Insight MySQL Database Password
+-----------------------+--------+---------------------------------------------------------+
Cisco VIM Insight backup Info!
+----------------------+-------+-------------------------------------------------------------------+
| Description
|
| Status| Details
+----------------------+-------+-------------------------------------------------------------------+
| Insight backup Status| PASS | Backup done @
|
| | |
/var/cisco/insight_backup/insight_backup_<release_tag>_<date_time>|
+----------------------+-------+-------------------------------------------------------------------+
Done with VIM Insight reconfigure!
VIM Insight reconfigure logs are at: "/var/log/insight/bootstrap_insight/"
As the summary table describes Insight gets autobacked up after reconfigure at
/var/cisco/insight_backup to preserve the latest state of Insight.
Reconfiguring Insight MySQL Database Password
There are two approaches to reconfigure MySQL DB password:
1 System generated Insight DB password.
2 User supplied Insight DB password.
System generated Insight DB password
Following are the steps to generate MySQL Insight DB password:
Procedure
Step 1 To generate the Insight DB Password run the following command:
# cd <insight_ws>
# ./bootstrap_insight.py
– a reconfigure – f <path_to insight_setup_data.yaml>
--regenerate_secrets
VIM Insight reconfigure logs are at: /var/log/insight/<bootstrap_insight_<date>_<time>.log
Perform the action. Continue (Y/N)y
Management Node Validations!
+-------------------------------+--------+-------+
| Rule | Status | Error |
+-------------------------------+--------+-------+
| Check Kernel Version | PASS | None |
| Check Docker Version | PASS | None |
| Check Management Node Tag | PASS | None |
| Check Bond Intf. Settings | PASS | None |
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
209
Day 2 Operations of Cisco VIM Insight
Reconfiguring Insight MySQL Database Password
| Root Password Check | PASS | None |
| Check Boot Partition Settings | PASS | None |
| Check LV Swap Settings | PASS | None |
| Check Docker Pool Settings | PASS | None |
| Check Home Dir Partition | PASS | None |
| Check Root Dir Partition | PASS | None |
| Check /var Partition | PASS | None |
| Check LVM partition | PASS | None |
| Check RHEL Pkgs Install State | PASS | None |
+-------------------------------+--------+-------+
Insight standalone Input Validations!
+-------------------------------------------+--------+-------+
| Rule | Status | Error |
+-------------------------------------------+--------+-------+
| Insight standalone Schema Validation | PASS | None |
| Valid Key Check in Insight Setup Data | PASS | None |
| Duplicate Key Check In Insight Setup Data | PASS | None |
| Config Change Check in Insight Setup Data | PASS | None |
+-------------------------------------------+--------+-------+
WARNING!! reconfigure will have few secs of Outage for Insight!
Cisco VIM Insight Already Exists!
+-----------------------+--------+---------------------------------------------------------+
| Description
|
| Status | Details
+-----------------------+--------+---------------------------------------------------------+
| VIM Insight UI URL | PASS | https://<br_api:9000>
|
| VIM UI Admin Email ID | PASS | Check for info @: <abs path of insight_setup_data.yaml>
|
|
| | |
| VIM UI Admin Password | PASS | Check for info @ /opt/cisco/insight/secrets.yaml
|
| VIM Insight Workspace | PASS | /root/<insight_ws>
|
+-----------------------+--------+---------------------------------------------------------+
Cisco VIM Insight backup Info!
+-----------------------+--------+--------------------------------------------------------------+
| Description | Status | Details
|
+-----------------------+--------+--------------------------------------------------------------+
| Insight backup Status | PASS | Backup done @
|
| | | /var/cisco/insight_backup/backup-<release_tag>-<date_time>
|
+-----------------------+--------+--------------------------------------------------------------+
Done with VIM Insight reconfigure!
VIM Insight reconfigure logs are at: "/var/log/insight/bootstrap_insight/"
As the summary table describes Insight gets autobacked up after reconfigure at
/var/cisco/insight_backup to preserve the latest state of Insight.
210
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
Day 2 Operations of Cisco VIM Insight
Reconfiguring Insight MySQL Database Password
Step 2 Verify the password change by running the following command:
# cat /opt/cisco/insight/secrets.yaml
DB_ROOT_PASSWORD: <new_db_password>
User supplied Insight DB password
Procedure
Step 1 To provide your own MYSQL DB Password follow the below steps:
Note Your new DB password must contain alphanumeric characters and should be at least 8 characters long.
# cd <insight_ws>
# ./bootstrap_insight.py
– a reconfigure – f <path_to insight_setup_data.yaml> --setpassword
VIM Insight reconfigure logs are at: /var/log/insight/<bootstrap_insight_<date>_<time>.log
Perform the action. Continue (Y/N)y
Password for DB_ROOT_PASSWORD: <enter_valid_db_password>
Management Node Validations!
+-------------------------------+--------+-------+
| Rule | Status | Error |
+-------------------------------+--------+-------+
| Check Kernel Version | PASS | None |
| Check Ansible Version | PASS | None |
| Check Docker Version | PASS | None |
| Check Management Node Tag | PASS | None |
| Check Bond Intf. Settings | PASS | None |
| Root Password Check | PASS | None |
| Check Boot Partition Settings | PASS | None |
| Check LV Swap Settings | PASS | None |
| Check Docker Pool Settings | PASS | None |
| Check Home Dir Partition | PASS | None |
| Check Root Dir Partition | PASS | None |
| Check /var Partition | PASS | None |
| Check LVM partition | PASS | None |
| Check RHEL Pkgs Install State | PASS | None |
+-------------------------------+--------+-------+
Insight standalone Input Validations!
+-------------------------------------------+--------+-------+
| Rule | Status | Error |
+-------------------------------------------+--------+-------+
| Insight standalone Schema Validation
| Valid Key Check in Insight Setup Data
| PASS | None |
| PASS | None |
| Duplicate Key Check In Insight Setup Data | PASS | None |
| Config Change Check in Insight Setup Data | PASS | None |
+-------------------------------------------+--------+-------+
WARNING!! reconfigure will have few secs of Outage for Insight!
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
211
Day 2 Operations of Cisco VIM Insight
Reconfiguring Insight MySQL Database Password
Cisco VIM Insight Already Exists!
+-----------------------+--------+---------------------------------------------------------+
| Description
| VIM Insight UI URL
|
| Status | Details
|
+-----------------------+--------+---------------------------------------------------------+
| PASS | https://<br_api:9000>
| VIM UI Admin Email ID | PASS | Check for info @: <abs path of insight_setup_data.yaml>
|
| | | |
| VIM UI Admin Password | PASS | Check for info @ /opt/cisco/insight/secrets.yaml
|
| VIM Insight Workspace | PASS | /root/<insight_ws>
|
+-----------------------+--------+---------------------------------------------------------+
Cisco VIM Insight backup Info!
+----------------------+-------+-------------------------------------------------------------------+
| Description
|
| Status| Details
+----------------------+-------+-------------------------------------------------------------------+
| Insight backup Status| PASS | Backup done @
|
| | |
/var/cisco/insight_backup/insight_backup_<release_tag>_<date_time>|
+----------------------+-------+-------------------------------------------------------------------+
Done with VIM Insight reconfigure!
VIM Insight reconfigure logs are at: "/var/log/insight/bootstrap_insight/"
As the summary table describes Insight gets autobacked up after reconfigure at
/var/cisco/insight_backup to preserve the latest state of Insight.
Step 2 Verify the password change by running the following command:
# cat /opt/cisco/insight/secrets.yaml
DB_ROOT_PASSWORD: <new_db_password>
Reconfigure Insight SMTP Server
Insight requires a valid SMTP Server to send mails to users (Pod-Admin, UI-Admin and regular users). If
SMTP Server goes down due to any reason you can reconfigure it.
Procedure
Step 1 Following are the steps to reconfigure the SMTP server:
# cd <path insight_setup_data.yaml>
Open insight_setup_data.yaml file
212
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
Day 2 Operations of Cisco VIM Insight
Reconfiguring Insight MySQL Database Password
# vi insight_setup_data.yaml
Edit the insight_setup_data.yaml to change value of INSIGHT_SMTP_SERVER key. Save the file after editing.
Note Only change in value of PEM_PATH and INSIGHT_SMTP_SERVER key is allowed during reconfigure. Any change detected in insight_setup_data.yaml other than these values will result in failure of Insight reconfigure.
Step 2 Run the bootstrap command as follows:
# cd <insight_ws>
# ./bootstrap_insight.py
– a reconfigure – f <path_to insight_setup_data.yaml>
VIM Insight reconfigure logs are at: /var/log/insight/<bootstrap_insight_<date>_<time>.log
Perform the action. Continue (Y/N)y
Management Node Validations!
+-------------------------------+--------+-------+
| Rule | Status | Error |
+-------------------------------+--------+-------+
| Check Kernel Version | PASS | None |
| Check Ansible Version | PASS | None |
| Check Docker Version | PASS | None |
| Check Management Node Tag | PASS | None |
| Check Bond Intf. Settings | PASS | None |
| Root Password Check | PASS | None |
| Check Boot Partition Settings | PASS | None |
| Check LV Swap Settings | PASS | None |
| Check Docker Pool Settings | PASS | None |
| Check Home Dir Partition | PASS | None |
| Check Root Dir Partition | PASS | None |
| Check /var Partition | PASS | None |
| Check LVM partition | PASS | None |
| Check RHEL Pkgs Install State | PASS | None |
+-------------------------------+--------+-------+
Insight standalone Input Validations!
+-------------------------------------------+--------+-------+
| Rule | Status | Error |
+-------------------------------------------+--------+-------+
| Insight standalone Schema Validation | PASS | None |
| Valid Key Check in Insight Setup Data | PASS | None |
| Duplicate Key Check In Insight Setup Data | PASS | None |
| Config Change Check in Insight Setup Data | PASS | None |
| Test Email Server for Insight | PASS | None |
+-------------------------------------------+--------+-------+
WARNING!! reconfigure will have few secs of Outage for Insight!
Cisco VIM Insight Already Exists!
+-----------------------+--------+---------------------------------------------------------+
| Description | Status | Details
|
+-----------------------+--------+---------------------------------------------------------+
| VIM Insight UI URL
|
| PASS | https://<br_api:9000>
| VIM UI Admin Email ID | PASS | Check for info @: <abs path of insight_setup_data.yaml>
|
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
213
Day 2 Operations of Cisco VIM Insight
Update VIM Insight
| | | |
| VIM UI Admin Password | PASS | Check for info @ /opt/cisco/insight/secrets.yaml
|
| VIM Insight Workspace | PASS | /root/<insight_ws>
|
+-----------------------+--------+---------------------------------------------------------+
Cisco VIM Insight backup Info!
+----------------------+-------+-------------------------------------------------------------------+
| Description
|
| Status| Details
+----------------------+-------+-------------------------------------------------------------------+
| Insight backup Status| PASS | Backup done @
|
| | |
/var/cisco/insight_backup/insight_backup_<release_tag>_<date_time>|
+----------------------+-------+-------------------------------------------------------------------+
Done with VIM Insight reconfigure!
VIM Insight reconfigure logs are at: "/var/log/insight/bootstrap_insight/"
As the summary table describes Insight gets autobacked up after reconfigure at
/var/cisco/insight_backup to preserve the latest state of Insight.
Update VIM Insight
VIM Insight Update provides you the feature to switch to a new Insight release.
Following are some of the key points:
Procedure
Step 1 The update action will make the old docker containers of insight and mariadb in exit state and bring up new ones with the new tag.
Step 2 The old containers and images are restored until you perform the Commit action.
Step 3 Update is an intermediate action, from this state either you can do a Commit action to settle for the current version or do a rollback to revert back to the old version.
Step 4 The old workspace will be preserved in case you want to do a rollback to the previous version.
Step 5 After update your Insight workspace will be the new workspace you just extracted out of the tar ball.
Step 6 After an update operation, backup and reconfigure action is not allowed from either old or new Insight workspace.
Note Do not delete your old Insight workspace until you have successfully performed a Commit to the new Insight update.
214
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
Day 2 Operations of Cisco VIM Insight
Update VIM Insight
Update Scenarios
Update action has the following scenarios:
• Insight and mariadb containers will get updated to a new tag.
• Either insight or mariadb container will get updated to a new tag.
Update VIM Insight with Internet Access
Following are the steps to update VIM Insight:
Procedure
Step 1 Get the new installer tar ball, which will be available after each release.
Extract the tar ball to get the new Insight workspace by running the following command:
# tar – xvzf mercury-installer.tar.gz
Step 2 Update the VIM insight by running the following commands:
# cd /root/<new_insight_ws>.
/bootstrap_insight.py
– a update
VIM Insight update logs are at: /var/log/insight/<bootstrap_insight_<date>_<time>.log
Management Node Validations!
+-------------------------------+--------+-------+
| Rule | Status | Error |
+-------------------------------+--------+-------+
| Check Kernel Version | PASS | None |
| Check Docker Version | PASS | None |
| Check Management Node Tag | PASS | None |
| Check Bond Intf. Settings | PASS | None |
| Root Password Check | PASS | None |
| Check Boot Partition Settings | PASS | None |
| Check LV Swap Settings | PASS | None |
| Check Docker Pool Settings | PASS | None |
| Check Home Dir Partition | PASS | None |
| Check Root Dir Partition | PASS | None |
| Check /var Partition | PASS | None |
| Check LVM partition | PASS | None |
| Check RHEL Pkgs Install State | PASS | None |
+-------------------------------+--------+-------+
Insight standalone Input Validations!
+-------------------------------------------+--------+-------+
| Rule | Status | Error |
+-------------------------------------------+--------+-------+
| Insight standalone Schema Validation
| Valid Key Check in Insight Setup Data
| PASS | None |
| PASS | None |
| Duplicate Key Check In Insight Setup Data | PASS | None |
| Config Change Check in Insight Setup Data | PASS | None |
+-------------------------------------------+--------+-------+
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
215
Day 2 Operations of Cisco VIM Insight
Update VIM Insight
Downloading Updated VIM Insight Artifacts, will take time!!!
Cisco VIM Insight update Info!
+------------------------------------------+--------+------------------------------+
| Description | Status | Details |
+------------------------------------------+--------+-------------------------------+
| VIM Insight Container: insight_<new_tag> | PASS | Updated from insight_<old_tag>|
| VIM Mariadb Container: mariadb_<new_tag> | PASS | Updated from mariadb_<old_tag>|
+------------------------------------------+--------+-------------------------------+
Done with VIM Insight update!
VIM Insight update logs are at: "/var/log/insight/bootstrap_insight/"
Step 3 Verify the Insight Update.
# ./bootstrap_insight.py
– a update-status
Cisco VIM Insight Update Status!
+------------------------------------------+--------+--------------------------------+
| Description | Status | Details |
+------------------------------------------+--------+--------------------------------+
| VIM Insight Container: insight_<new_tag> | PASS | Updated from insight_<old_tag> |
| VIM Mariadb Container: insight_<new_tag> | PASS | Updated from mariadb_<old_tag> |
+------------------------------------------+--------+--------------------------------+
VIM Insight without Internet Access
Procedure
Step 1 Copy the new installer tar ball to the Insight Management Node.
Extract the tar ball to get the new Insight workspace by running the following command:
# tar – xvzf mercury-installer.tar.gz
Step 2 To download the new Insight artifacts follow the steps given in Cisco_NFVI_Install_Guide_2_2 under
Preparing to Install Cisco NFVI on Management Nodes Without Internet Access, page 41.
Step 3 Run Import Artifacts:
# cd /root/installer_<tag_id>/tools
# ./import_artifacts.sh
This verifies that /var/cisco/artifcats on the management node has the following Insight artifacts, along with the other components 'insight-K9.tar' and 'mariadb-app-K9.tar'.'
Step 4 Update the Insight by running the following command:
# cd ../insight/
# ./bootstrap_insight.py
– a update
VIM Insight update logs are at: /var/log/insight/<bootstrap_insight_<date>_<time>.log
Management Node Validations!
216
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
Day 2 Operations of Cisco VIM Insight
Update VIM Insight
+-------------------------------+--------+-------+
| Rule | Status | Error |
+-------------------------------+--------+-------+
| Check Kernel Version | PASS | None |
| Check Ansible Version | PASS | None |
| Check Docker Version | PASS | None |
| Check Management Node Tag | PASS | None |
| Check Bond Intf. Settings | PASS | None |
| Root Password Check | PASS | None |
| Check Boot Partition Settings | PASS | None |
| Check LV Swap Settings | PASS | None |
| Check Docker Pool Settings | PASS | None |
| Check Home Dir Partition | PASS | None |
| Check Root Dir Partition | PASS | None |
| Check /var Partition | PASS | None |
| Check LVM partition | PASS | None |
| Check RHEL Pkgs Install State | PASS | None |
+-------------------------------+--------+-------+
Insight standalone Input Validations!
+-------------------------------------------+--------+-------+
| Rule | Status | Error |
+-------------------------------------------+--------+-------+
| Insight standalone Schema Validation
| Valid Key Check in Insight Setup Data
| PASS | None |
| PASS | None |
| Duplicate Key Check In Insight Setup Data | PASS | None |
| Config Change Check in Insight Setup Data | PASS | None |
+-------------------------------------------+--------+-------+
Updating VIM Insight, Kindly wait!!!
Cisco VIM Insight update Info!
+------------------------------------------+--------+------------------------------+
| Description | Status | Details |
+------------------------------------------+--------+-------------------------------+
| VIM Insight UI URL | PASS | https://<br_api:9000> |
| VIM Insight Container: insight_<new_tag> | PASS | Updated from insight_<old_tag>|
| VIM Mariadb Container: mariadb_<new_tag> | PASS | Updated from mariadb_<old_tag>|
| VIM Insight Workspace | PASS | /root/<new_insight_ws> |
+------------------------------------------+--------+-------------------------------+
Done with VIM Insight update!
VIM Insight update logs are at: "/var/log/insight/bootstrap_insight/"
Step 5 Verify Insight Update by running the following command:
# ./bootstrap_insight.py
– a update-status
Cisco VIM Insight Update Status!
+------------------------------------------+--------+--------------------------------+
| Description | Status | Details |
+------------------------------------------+--------+--------------------------------+
| VIM Insight Container: insight_<new_tag> | PASS | Updated from insight_<old_tag> |
| VIM Mariadb Container: insight_<new_tag> | PASS | Updated from mariadb_<old_tag> |
+------------------------------------------+--------+--------------------------------+
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
217
Day 2 Operations of Cisco VIM Insight
Update VIM Insight
Rollback VIM Insight
VIM Insight Rollback provides feature to revert to the old Insight release which is used before update.
Following are some key points related to the same.
• The rollback action removes the new docker containers of insight and mariadb which got created after an update and bring up old ones with the old tag.
• The new workspace will be left as it is in case you want to do an update operation later or in case VIM may be running from it.
• After rollback your Insight workspace will be the old workspace which you were using before update.
Following are the steps to perform Insight rollback:
Procedure
Step 1 Run the following command to rollback VIM Insight:
# cd /root/<new_insight_ws>
# ./bootstrap_insight.py
– a rollback
VIM Insight rollback logs are at: /var/log/insight/<bootstrap_insight_<date>_<time>.log
Management Node Validations!
+-------------------------------+--------+-------+
| Rule | Status | Error |
+-------------------------------+--------+-------+
| Check Kernel Version | PASS | None |
| Check Ansible Version | PASS | None |
| Check Docker Version | PASS | None |
| Check Management Node Tag | PASS | None |
| Check Bond Intf. Settings | PASS | None |
| Root Password Check | PASS | None |
| Check Boot Partition Settings | PASS | None |
| Check LV Swap Settings | PASS | None |
| Check Docker Pool Settings | PASS | None |
| Check Home Dir Partition | PASS | None |
| Check Root Dir Partition | PASS | None |
| Check /var Partition | PASS | None |
| Check LVM partition | PASS | None |
| Check RHEL Pkgs Install State | PASS | None |
+-------------------------------+--------+-------+
Insight standalone Input Validations!
+-------------------------------------------+--------+-------+
| Rule | Status | Error |
+-------------------------------------------+--------+-------+
| Insight standalone Schema Validation | PASS | None |
| Valid Key Check in Insight Setup Data | PASS | None |
| Duplicate Key Check In Insight Setup Data | PASS | None |
218
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
Day 2 Operations of Cisco VIM Insight
Commit VIM Insight
| Config Change Check in Insight Setup Data | PASS | None |
+-------------------------------------------+--------+-------+
VIM Insight rollback in progress, Kindly wait!!!
Cisco VIM Insight rollback Info!
+------------------------------------------+--------+-------------------------------+
| Description | Status | Details |
+------------------------------------------+--------+--------------------------------+
| VIM Insight UI URL | PASS | https://<br_api:9000> |
| VIM Insight Container: insight_<old_tag> | PASS | Rollback from insight_<new_tag>|
| VIM Mariadb Container: mariadb_<old_tag> | PASS | Rollback from mariadb_<new_tag>|
| VIM Insight Workspace | PASS | /root/<old_insight_ws> |
+------------------------------------------+--------+--------------------------------+
Done with VIM Insight rollback!
VIM Insight rollback logs are at: "/var/log/insight/bootstrap_insight/"
Step 2 Verify Rollback Status by running the following command:
# ./bootstrap_insight.py
– a install-status
Cisco VIM Insight Install Status!
+-----------------------+--------+----------------------------------+
| Description | Status | Details |
+-----------------------+--------+----------------------------------+
| VIM Insight Version | PASS | <release_tag> |
| VIM Insight UI URL | PASS | https://<br_api:9000>
| VIM Insight Container | PASS | insight_<tag_id>
| VIM Mariadb Container | PASS | mariadb_<tag_id>
| VIM Insight Workspace | PASS | /root/<insight_ws> |
+-----------------------+--------+----------------------------------+
|
|
|
Commit VIM Insight
Follow the below mentioned steps to perform Insight commit:
Procedure
Step 1 Execute the following command to commit the VIM Insight:
# cd /root/<new_insight_ws>
Step 2 Run the bootstrap command as follows:
# ./bootstrap_insight.py
– a commit
VIM Insight commit logs are at: /var/log/insight/<bootstrap_insight_<date>_<time>.log
Management Node Validations!
+-------------------------------+--------+-------+
| Rule | Status | Error |
+-------------------------------+--------+-------+
| Check Kernel Version | PASS | None |
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
219
Day 2 Operations of Cisco VIM Insight
Commit VIM Insight
| Check Docker Version | PASS | None |
| Check Management Node Tag | PASS | None |
| Check Bond Intf. Settings | PASS | None |
| Root Password Check | PASS | None |
| Check Boot Partition Settings | PASS | None |
| Check LV Swap Settings | PASS | None |
| Check Docker Pool Settings | PASS | None |
| Check Home Dir Partition | PASS | None |
| Check Root Dir Partition | PASS | None |
| Check /var Partition | PASS | None |
| Check LVM partition | PASS | None |
| Check RHEL Pkgs Install State | PASS | None |
+-------------------------------+--------+-------+
Insight standalone Input Validations!
+-------------------------------------------+--------+-------+
| Rule | Status | Error |
+-------------------------------------------+--------+-------+
| Insight standalone Schema Validation
| Valid Key Check in Insight Setup Data
| PASS | None |
| PASS | None |
| Duplicate Key Check In Insight Setup Data | PASS | None |
| Config Change Check in Insight Setup Data | PASS | None |
+-------------------------------------------+--------+-------+
VIM Insight commit in progress, Kindly wait!!!
Cisco VIM Insight commit Info!
+------------------------------------------+--------+---------------------------------------+
| Description
|
| Status | Details
+------------------------------------------+--------+----------------------------------------+
| VIM Insight UI URL | PASS | Error! Hyperlink reference not valid.> |
| VIM Insight Container: insight_<new_tag> | PASS | Old container:insight_<old_tag> removed|
| VIM Mariadb Container: mariadb_<new_tag> | PASS | Rollback from mariadb_<old_tag> removed|
| VIM Insight Workspace
|
| PASS | /root/<new_insight_ws>
+------------------------------------------+--------+----------------------------------------+
Done with VIM Insight commit!
VIM Insight commit logs are at: "/var/log/insight/bootstrap_insight/"
Step 3 Verify the Insight status by running the following command:
Verify Insight status
# ./bootstrap_insight.py
– a install-status
Cisco VIM Insight Install Status!
220
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
Day 2 Operations of Cisco VIM Insight
Commit VIM Insight
+-----------------------+--------+----------------------------------+
| Description | Status | Details |
+-----------------------+--------+----------------------------------+
| VIM Insight Version | PASS | <release_tag> |
| VIM Insight UI URL | PASS | https://<br_api:9000>
| VIM Insight Container | PASS | insight_<tag_id>
| VIM Mariadb Container | PASS | mariadb_<tag_id>
| VIM Insight Workspace | PASS | /root/<insight_ws> |
+-----------------------+--------+----------------------------------+
|
|
|
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
221
Commit VIM Insight
Day 2 Operations of Cisco VIM Insight
222
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
C H A P T E R
11
Overview to the Cisco Virtual Topology System
The Cisco Virtual Topology System (VTS) is an optional Cisco NFVI application that uses the Neutron driver and supports Cisco Vector Packet Processing. The following topics provide an overview to VTS architecture and features. When using VTS with Cisco NFVI, keep the following OpenStack tenant restrictions in mind:
Restriction
Nova flavors: VM RAM > 512MB and equal to a multiple of 512MB
Description
This limitation is due to NUMA and huge pages.
Nova Flavors: nova flavor-key m1.medium set hw:mem_page_size=large
VHOST mode is the only mode supported by the
VTS installation at this time. To support VHOST connections nova needs the following configurations on each flavor that will be used.
•
Understanding Cisco VTS, page 223
•
Cisco VTS Architecture Overview, page 224
•
Virtual Topology Forwarder, page 225
•
Virtual Topology System High Availability, page 227
Understanding Cisco VTS
The Cisco Virtual Topology System (VTS) is a standards-based, open, overlay management and provisioning system for data center networks. It automates DC overlay fabric provisioning for both physical and virtual workloads.
Cisco VTS provides a network virtualization architecture and software-defined networking (SDN) framework that meets the requirements of multitenant data centers for cloud services. It enables a policy-based approach for overlay provisioning.
Cisco VTS automates complex network overlay provisioning and management tasks through integration with cloud orchestration systems such as OpenStack and VMware vCenter and abstracts out the complexity involved in managing heterogeneous network environments. The solution can be managed from the embedded Cisco
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
223
Overview to the Cisco Virtual Topology System
Cisco VTS Architecture Overview
VTS GUI or entirely by a set of northbound Representational State Transfer (REST) APIs that can be consumed by orchestration and cloud management systems.
Cisco VTS provides:
• Fabric automation
• Programmability
• Open, scalable, standards based solution
• Cisco Nexus 2000, 3000, 5000, 7000, and 9000 Series Switches. For more information, see Supported
Platforms in Cisco VTS 2.5 Installation Guide .
• Software forwarder (Virtual Topology Forwarder [VTF])
Cisco VTS Architecture Overview
Cisco VTS architecture has two main components: the Policy Plane and the Control Plane. These perform core functions such as SDN control, resource allocation, and core management function.
Figure 21: Cisco VTS Architecture
• Policy Plane : The policy plane enables Cisco VTS to implement a declarative policy model designed to capture user intent and render it into specific device-level constructs. The solution exposes a set of modular policy constructs that can be flexibly organized into user-defined services for use cases across service provider and cloud environments. These policy constructs are exposed through a set of REST
224
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
Overview to the Cisco Virtual Topology System
Virtual Topology Forwarder
APIs that can be consumed by orchestrators and applications to express user intent, or instantiated through the Cisco VTS GUI. Policy models are exposed as system policies or service policies.
System policies allow administrators to logically group devices into pods within or across data centers to define Admin Domains with common system parameters (for example, BGP-EVPN control plane with distributed Layer 2 and 3 gateways).
The inventory module maintains a database of the available physical entities (for example, data center interconnect [DCI] routers and top-of-rack leaf, spine, and border-leaf switches) and virtual entities (for example, VTFs) in the Virtual Topology System domain. The database also includes interconnections between these entities and details about all services instantiated within a Virtual Topology System domain.
The resource management module manages all available resource pools in the Virtual Topology System domain, including VLANs, VXLAN Network Identifiers (VNIs), IP addresses, and multicast groups.
• Control Plane : The control plane module serves as the SDN control subsystem that programs the various data planes including the VTFs residing on the x86 servers, hardware leafs, DCI gateways. The Control plane hosts Service Routing (SR) module, which provides routing services to Cisco VTS. The Service
Routing (SR) module is responsible for calculating L2 and L3tables and routes to provide connectivity between the different VMs for a given tenant and service chaining. The main components of this module are the VTSR and VTF. VTSR is the controller and Virtual topology forwarder (VTF) runs on each compute server hosting the tenant VMs.
Virtual Topology Forwarder
Virtual Topology Forwarder (VTF) runs on each compute server in the DC and provides connectivity to all tenant VMs hosted on the compute server. VTF supports both intra and inter DC/WAN connectivity. VTF allows Cisco VTS to terminate VXLAN tunnels on host servers by using the VTF as a Software VXLAN
Tunnel Endpoint (VTEP). Cisco VTS also supports hybrid overlays by stitching together physical and virtual endpoints into a single VXLAN segment.
VTF has 2 major components — Cisco's VPP (Vector Packet Processing)and VPFa. VPFA is a Cisco agent running on each VMM compute resource. VPFA is FIB agent which receives L2/L3 table forwarding information from VTSR needed to provide the connectivity to local tenant VMs hosted on its compute, and programs them in the VPP.
VTF is deployed as a virtual machine or in vhost mode, to deliver a high-performance software data plane on a host server.
Overview to Cisco VTF and VPP
Cisco VTF is a Cisco Soft switch built on the Cisco Vector Packet Processing (VPP) technology.
The VPP platform is an extensible framework that provides extremely productive and quality switch/router functionality. It is the open source version of the Cisco VPP technology, which is a high performance, packet-processing stack that can run on commodity CPUs.
The benefits of VPP are its high performance, proven technology, modularity, flexibility, and rich feature set.
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
225
Overview to the Cisco Virtual Topology System
Overview to Cisco VTF and VPP
The VPP platform is built on a packet-processing graph. This modular approach allows anyone to plugin new graph nodes. This makes extensibility rather simple, and the plugins can be customized for specific purposes.
Figure 22: VPP Platform
The VPP platform grabs all available packets from RX rings to form a vector of packets. A packet-processing graph is applied, node by node (including plugins) to the entire packet vector. Graph nodes are small and modular, and loosely coupled which makes it easy to include new graph nodes and rewire existing graph nodes.
A plugin can introduce new graph nodes or rearrange the packet-processing graph. You can also build a plugin independent from the VPP source and consider it as an independent component. A plugin can be installed by adding it to a plugin directory.
VTF uses remote plugin that binds into VPP using VPFA (VPF agent). The VPFA interacts with VPP application using low level API. The VPFA exposes netconf or yang based API for remote devices to program the VTF through the VPFA.
VPP + VHOSTUSER
vhost is a solution that allows the user space process to share a number of virtqueues directly with a Kernel driver. The transport mechanism in this case is the ability of the kernel side to access the user space application memory, and a number of ioeventfds and irqfds to serve as the kick mechanism. A QEMU guest uses an emulated PCI device, as the control plane is still handled by QEMU. However once a virtqueue has been set up, the QEMU guest will use the vhost API to pass direct control of a virtqueue to a Kernel driver.
226
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
Overview to the Cisco Virtual Topology System
Virtual Topology System High Availability
In this model, a vhost_net driver directly passes the guest network traffic to a TUN device directly from the
Kernel side, improving performance significantly.
Figure 23: VTF vhost
In the above implementation, the guest NFV application directly writes packets into the TX rings, which is shared through a common vhost socket as the RX ring on the VPP . The VPP grabs these packets from the
RX ring buffer and forwards the packets using the vector graphs it maintains.
Virtual Topology System High Availability
The Virtual Topology System solution is designed to support redundancy, with two solution instances running on separate hosts in an active-standby configuration.
During initial setup, each instance is configured with both an underlay IP address and a virtual IP address.
Virtual Router Redundancy Protocol (VRRP) is used between the instances to determine which instance is active.
The active-instance data is synchronized with the standby instance after each transaction to help ensure consistency of the control-plane information to accelerate failover after a failure. BGP peering is established from both Virtual Topology System instances for the distribution of tenant-specific routes. During the switchover, nonstop forwarding (NSF) and graceful restart help ensure that services are not disrupted.
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
227
Overview to the Cisco Virtual Topology System
Virtual Topology System High Availability
See the Installing VTS in High Availability Mode section of the Cisco VTS 2.5.2 Installation Guide for the detailed procedure about setting up high availability.
228
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
C H A P T E R
12
Managing Backup and Restore Operations
The following topics describe Cisco NFVI management node backup and restore operations.
•
Managing Backup and Restore Operations, page 229
•
Restoring the Management Node, page 236
•
Management Node Auto-backup, page 238
Managing Backup and Restore Operations
The management node hosts critical services such as Cisco VIM REST API, Cobbler for PXE, ELK for
Logging/Kibana dashboard, and VMTP for cloud validation in Cisco VIM.
The management node is not redundant during the initial Cisco VIM offering, hence it is recommended to take backup of the management node. Using the saved management node information, you can restore the management node if you are facing any issues with the platform.
Backing up the Management Node
An administrator must maintain the number of back up snapshots on the management node. The backup of the management node is possible only after complete deployment of at least one Cisco VIM. Two copies of backup directories are maintained at the management node itself and the older copy will be overwritten when a next backup is performed.
During the backup operation, activities such as pod management, software update or upgrade, and addition or deletion or replacement of nodes cannot be performed.
The REST API and ELK services are stopped during the backup operation, the OpenStack logs are cached on the control, compute, and storage nodes till the restoration of the management node is completed.
As part of the backup operation, two files are created: .backup_files and .backup_hash. .backup_files is a list of files that are backed up, while the second one is the hash. These two files are placed under the backup directory /var/cisco/backup_<tag>_<date-time> at the management node and also at the /var/cisco/ directory of all three controllers. These two files are used during the restore validation. When user attempt to restore from a particular backup, these two files within this backup are compared to those at the controllers. If there is any discrepancy, the restore validation will fail and user will be prompted to either terminate the restore operation or continue despite the validation failure. Only one copy of the .backup_files and .backup_hash are
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
229
Managing Backup and Restore Operations
Backing up the Management Node kept at the controllers, that is every time a new backup is created, these two files are overwritten with the most recent ones. Hence the restore validation will only pass when the latest backup is used for restore.
Figure 24: Cisco NFVI Management Node Backup Operation
Before You Begin
• Save the management node information (for example, IP address of the management node) for use during the restore operation.
• Ensure that you have the br_mgmt and br_api IP addresses and respective network information.
Procedure
Step 1 Launch a SSH session to the Cisco NFVI management node.
Step 2 Navigate to the <installer-ws>/tools/mgmt/ directory.
Step 3 Execute mgmt_node_backup.py
.
What to Do Next
The backup operation takes approximately 30 minutes and creates the backup_<tag>_<date-time> directory in the /var/cisco/ path.
Copy the directory to a remote server to recover the management node using rsync.
For example, to copy the backup directory to the remote server 20.0.0.5 /var/cisco/directory , execute the following command sequence: rsync -e ssh -rtvpX --numeric-ids /var/cisco/backup_2017-01-09_14-04-38 [email protected]:/var/cisco/
Note On the remote server, protect the backup directory for any unauthorized access as the backup files may contain sensitive information
At the remote server, change directory to where the backup directory is copied to; in this example
/var/cisco/backup_<tag>_<date-time>/.
To verify if the backup is not corrupted or modified, execute ./check_integrity .
230
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
Managing Backup and Restore Operations
Backup with Forwarding ELK logs to External Syslog Server
Check_integrity depends on the following packages, they should be installed on the server where check_integrity is executed.
python-prettytable python-jinja2 python-babel python-markupsafe python-setuptools pytz
Backup with Forwarding ELK logs to External Syslog Server
When the feature Forwarding ELK logs to External Syslog Server is enabled, during the backup process, in both the auto-backup and manual backup, the ELK logs are not collected. For manual backups, user can override by appending the -a or --add-elk option to the backup command. The -s or --skip-elk option is to skip the ELK logs collection regardless of the forwarding feature is enabled or not.
# cd installer/tools/mgmt
# ./mgmt_node_backup.py --help
Usage: ./mgmt_node_backup.py [options]
Options:
-h, --help show this help message and exit
-s, --skip-elk do not collect ELK logs during backup
-a, --add-elk force to also collect ELK logs on backup
Backing up VIM Insight
Administrator maintains the backup for Insight on the management node. The backup of the Insight is done only after the complete deployment of the Insight bootstrap. Only two copies of backup directory are maintained at the management node. The older copy will be overwritten when a next Insight backup/autobackup takes place.
Insight backup is stored at default backup location
/var/cisco/insight_backup/insight_backup_<release_tag>_<date>_<time>. If a user wants to take a backup of Insight at a different location use -backupdir/-b option from bootstrap_insight; details of which are provided later in this section.
Insight UI will also trigger an autobackup whenever it detects an operation relating to MySQL database entry to preserve the latest state of Insight.
Note Insight backup is not allowed after an update. Update is an intermediate stage between rollback and commit.
Any change made relating to MySQL database entry after an update from Insight UI will not be backed up.
Autobackup Insight
If there is a change, Insight Installation will automatically run a daemon process to take the autobackup.
Live status of the process is determined by checking the log located at
"/var/log/insight/insight_autobackup/insight_autobackup.logs" or systemctl status insight-autobackup.
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
231
Managing Backup and Restore Operations
Backing up VIM Insight
Note Max of 10 log files of size 1024*1024 are maintained in the directory.
Following are the scenarios where autobackup is initiated:
Insight Operation
Adding/Deleting POD
Auto-backup Performed
Yes
Changing POD REST Password and Certificate
Add/Edit/Delete all types of users
Yes
Yes
Add/Edit/Delete Roles
Modify User and Role association
Revoking/Adding user permission
Login/Logout
Context Switching
Change User Password
No
No
Yes
Yes
Yes
Yes
Procedure
Step 1 To check the status of the Insight follow the below steps: systemctl status insight-autobackup insight-autobackup.service - Insight Autobackup Service
Loaded: loaded (/usr/lib/systemd/system/insight-autobackup.service; enabled; vendor preset: disabled)
Active: active (running) since Wed 2017-08-30 01:17:18 PDT; 19s ago
Main PID: 19949 (python)
Memory: 12.4M
CGroup: /system.slice/insight-autobackup.service
└─ 19949 /usr/bin/python
/root/<installer-tag>/insight/playbooks/../insight_autobackup.py
Step 2 To stop Insight autobackup by following the below steps: systemctl stop insight-autobackup insight-autobackup.service - Insight Autobackup Service
Loaded: loaded (/usr/lib/systemd/system/insight-autobackup.service; enabled; vendor preset: disabled)
Active: inactive (dead) since Mon 2017-09-04 00:43:43 PDT; 5s ago
Process: 19993 ExecStop=/bin/kill ${MAINPID} (code=exited, status=0/SUCCESS)
Main PID: 19984
Memory: 56.0K
CGroup: /system.slice/insight-autobackup.service
232
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
Managing Backup and Restore Operations
Backing up VIM Insight
Step 3 To start Insight autobackup by following the below steps: systemctl start insight-autobackup insight-autobackup.service - Insight Autobackup Service
Loaded: loaded (/usr/lib/systemd/system/insight-autobackup.service; enabled; vendor preset: disabled)
Active: active (running) since Wed 2017-08-30 01:17:18 PDT; 19s ago
Main PID: 19949 (python)
Memory: 12.4M
CGroup: /system.slice/insight-autobackup.service
└─ 19949 /usr/bin/python
/root/<installer-tag>/insight/playbooks/../insight_autobackup.py
Step 4 The way Insight works is as follows:
1 Install
• As soon as galera db and insight containers are up the script will be invoked.
• Log dir : tailf /var/log/insight/insight_autobackup_logs/insight_autobackup.log.
• It has a 10 seconds pulse which will tell if the service is up or not.
• [ 2017-09-04 00:49:01,504] INFO [Insight Autobackup] Insight Autobackup Service Running.
• [2017-09-04 00:49:11,514] INFO [Insight Autobackup] Insight Autobackup Service Running.
• [2017-09-04 00:49:21,525] INFO [Insight Autobackup] Insight Autobackup Service Running.
• If there is any change it will take a backup (time to check Sql diff is 30 seconds).
• It will create "rbac_latest.sql" and "insight_latest.tar.gz" and dump in the latest backup dir.
• During restore the bootstrap script will check if "rbac_latest.sql" or "insight_latest.tar.gz" is present in the backup dir if not it will work the way it used to work earlier.
2 Update
• During update bootstrap insight does not support backup.
• Autobackup service would be terminated and no backup would be maintained in the intermediate state.
3 Rollback
• Script will be invoked again from the previous workspace.
4 Commit
• Script will be invoked again from the new workspace.
5 Uninstall
• Service file will be deleted.
• Log directory will remain as the same.
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
233
Managing Backup and Restore Operations
Backing up VIM Insight
Backup Insight at default backup location
Procedure
Step 1 Launch a SSH session to Cisco Insight management node and follow the below steps:
# cd <insight-ws>
#./bootstrap_insight.py
– help usage: bootstrap_insight.py [-h] – -action ACTION
[--regenerate_secrets] [--setpassword]
[--file INSIGHTSETUPDATA] [--keep] [--verbose]
[--backupdir BACKUPDIR] [-y]
Insight install setup helper.
optional arguments:
-h, --help show this help message and exit
--action ACTION, -a ACTION install - Install Insight UI install-status - Display Insight Install Status reconfigure - Reconfigure Insight DB password or TLS update - Update Insight UI
Certificate update-status - Display Insight Update Status rollback - Rollback Insight UI update commit - Commit Insight UI update backup - Backup Insight UI uninstall - Uninstall Insight UI
--regenerate_secrets, -r
--setpassword, -s
System generated INSIGHT_DB_PASSWORD
User supplied INSIGHT_DB_PASSWORD,
--file INSIGHTSETUPDATA, -f INSIGHTSETUPDATA
Location of insight_setup_data.yaml
--keep, -k
--verbose, -v
Preserve Insight artifacts during uninstall
Verbose on/off
--backupdir BACKUPDIR, -b BACKUPDIR
Path to backup Insight
-y, --yes Option to skip reconfigure or uninstall steps without prompt
Step 2 Run the bootstrap command to view the Cisco VIM Insight backup details:
# ./bootstrap_insight.py
– a backup
VIM Insight backup logs are at: /var/log/insight/<bootstrap_insight_<date>_<time>.log
Cisco VIM Insight backup Info!
+----------------------+-------+-------------------------------------------------------------------+
| Description | Status| Details
|
+----------------------+-------+-------------------------------------------------------------------+
| Insight backup Status| PASS | Backup done @
|
| | |
234
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
Managing Backup and Restore Operations
Backing up VIM Insight
/var/cisco/insight_backup/insight_backup_<release_tag>_<date_time>|
+----------------------+-------+-------------------------------------------------------------------+
Done with VIM Insight backup!
Backup Insight at user defined backup location
Procedure
Step 1 Launch a SSH session to Cisco Insight management node and follow the below steps:
# cd <insight-ws>
#./bootstrap_insight.py
– help usage: bootstrap_insight.py [-h] – -action ACTION
[--regenerate_secrets] [--setpassword]
[--file INSIGHTSETUPDATA] [--keep] [--verbose]
[--backupdir BACKUPDIR] [-y]
Insight install setup helper.
optional arguments:
-h, --help show this help message and exit
--action ACTION, -a ACTION install - Install Insight UI install-status - Display Insight Install Status reconfigure - Reconfigure Insight DB password or TLS Certificate update - Update Insight UI update-status - Display Insight Update Status rollback - Rollback Insight UI update commit - Commit Insight UI update backup - Backup Insight UI uninstall - Uninstall Insight UI
--regenerate_secrets, -r
System generated INSIGHT_DB_PASSWORD
--setpassword, -s User supplied INSIGHT_DB_PASSWORD,
--file INSIGHTSETUPDATA, -f INSIGHTSETUPDATA
--keep, -k
--verbose, -v
Location of insight_setup_data.yaml
Preserve Insight artifacts during uninstall
Verbose on/off
--backupdir BACKUPDIR, -b BACKUPDIR
-y, --yes
Path to backup Insight
Option to skip reconfigure or uninstall steps without prompt
Step 2 Run the following command to view the Cisco VIM Insight backup details:
# ./bootstrap_insight.py
– a backup – -backupdir <user_defined_path>
VIM Insight backup logs are at: /var/log/insight/<bootstrap_insight_<date>_<time>.log
Cisco VIM Insight backup Info!
+-----------------------+--------+----------------------------------------------------------+
| Description
|
| Status | Details
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
235
Managing Backup and Restore Operations
Restoring the Management Node
+-----------------------+--------+----------------------------------------------------------+
| Insight backup Status | PASS | Backup done @ <user_defined_path>
|
| | |
|
+-----------------------+--------+----------------------------------------------------------+
Done with VIM Insight backup!
What to Do Next
Copy the backup directory to a remote server using rsync to recover the Insight later. We recommend you to copy backup dir using rsync as it preserves the permissions of the files.
For example, to copy the backup directory to the remote server 20.0.0.5 /var/cisco/insight_backup/directory
, execute the following command sequence: .
rsync -e ssh -rtvpX --numeric-ids
/var/cisco/insight_backup/insight_backup_2.1.5_2017-01-09_14-04-38 [email protected]:/var/cisco/insight_backup/
On the remote server, protect the backup directory for any unauthorized access, as the backup files may contain sensitive information
Restoring the Management Node
As an administrator, you have to re-image the management node with the same ISO version when the backup is performed, before initiating the restore operation. Restore will fail when there is a version mismatch.
Note Version checking is available only for offline installation.
As part of the restore operation, system checks for management node's IP address information to match the prior configuration. Logs are cached on the control, compute and storage nodes from the moment of the management node fails until its restoration.
If you are using Cisco VIM Insight (in Tech Preview), in the same management node, you will have to re-bootstrap it for installation. During installation, RBAC and Pod registration information will be lost, hence it is advised to make a note of the RBAC and Pod information.
Figure 25: Cisco NFVI Management Node Restore Operation
236
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
Managing Backup and Restore Operations
Restoring the Management Node
Before You Begin
Ensure that you have the br_mgmt and br_api IP addresses of the failed management node.
Procedure
Step 1 Re-image the management node with the ISO version with which you want to restore the node, and with the same IP address that is used before the failure of the node.
Step 2 Navigate to /var/cisco/directory at the remote server where the backup directory is copied during the backup operation. Execute ./check_integrity to verify if the backup is not corrupted or modified.
Step 3 Copy the backup file to the /var/cisco/directory of the re-imaged management node.
For example, to copy the backup directory from the remote host 20.0.0.5 to the management node
/var/cisco/directory, execute the following command sequence: rsync -e ssh -rtvpX --numeric-ids [email protected]:/var/cisco/backup_2017-01-09_14-04-38
/var/cisco/
Step 4 Navigate to the backup directory and execute the following command to verify if the backup is not corrupted or modified.
# cd /var/cisco/backup_<date-time>
# ./check-integrity
Step 5 In /var/cisco/backup_<date-time> directory, execute the following command:
/var/cisco/backup_<date-time> # ./restore
The restore operation takes around 45 minutes.
Step 6 Before restoration, the restore script performs validation of the backup directory. If validation fails, restore operation will be halted and an error message will be displayed. The script will also verify the last performed backup directory in the Management Node, and if any defects are detected, the user needs to confirm to proceed with restore operation.
…
2017-02-02 21:25:23 INFO Starting Cisco VIM restore...
2017-02-02 21:25:23 INFO Cisco VIM restore: estimated run time is approx. 45 mins...
2017-02-02 21:25:23 INFO Please see progress log for restore at
/var/log/mercury/installer/restore_2017-02-02_21:25:23.log
2017-02-02 21:25:27 ERROR Error: Backup id is not the one expected
Error: Found hashID file only in controller(s): j10-controller-2, j10-controller-3
Management backup files are ok (as per j10-controller-2)
Management backup files are ok (as per j10-controller-3)
The management node changed after the last backup was stored. Do you still want to proceed restoring this management node? [Y/n] y
2017-02-02 22:17:55 INFO Workspace restored to /root/installer-6518
2017-02-02 22:17:55 INFO Cisco VIM restore: Executing restore playbook ...
2017-02-02 22:18:47 INFO Cisco VIM restore: Executing bootstrap playbook ...
Note The default behavior is to continue by keying Return or Y . Keying N will abort the restore operation.
…
2017-02-02 21:25:23 INFO Starting Cisco VIM restore...
2017-02-02 21:25:23 INFO Cisco VIM restore: estimated run time is approx. 45 mins...
2017-02-02 21:25:23 INFO Please see progress log for restore at
/var/log/mercury/installer/restore_2017-02-02_21:25:23.log
2017-02-02 21:25:27 ERROR Error: Backup id is not the one expected
Error: Found hashID file only in controller(s): j10-controller-2, j10-controller-3
Management backup files are ok (as per j10-controller-2)
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
237
Managing Backup and Restore Operations
Management Node Auto-backup
Management backup files are ok (as per j10-controller-3)
The management node changed after the last backup was stored. Do you still want to proceed restoring this management node? [Y/n] n
Aborting the restore operation as per user request
Once restore operation ends, several health check points will be automatically executed and the summary of results for that particular cloud reachability will be display.
Step 7 User can run the following checks manually to verify the status of the restore:
• Check the status of the REST API server:
# cd installer-<tagid>/tools
#./restapi.py -a status
Status of the REST API Server: active (running) since Thu 2016-08-18 09:15:39 UTC; 9h ago
REST API launch directory: /root/installer-<tagid>/
• Check the setup_data and runtime consistency of the management node:
# cd installer-<tagid>/; ciscovim run – perform 1,3 – y
• Execute the cloud sanity command:
# cd installer-<tagid>/tools
# ./cloud_sanity.py -c all
Management Node Auto-backup
After the successful completion of certain Pod management operations, a backup of the management node is performed automatically. Only one copy of the auto-backup directory is kept at /var/cisco/ at any given time.
The directory format is autobackup_<tag>_<timestamp>
Below is a list of operations:
• Fresh install of Cisco VIM
• Commit an update
• Replace controller
• Add or Remove compute nodes
• Add or Remove storage node
• Reconfigure
• NFVIMON
Enabling or disabling the variable auto-backup, is defined in the setup_data.yaml file. It is enabled by default.
Add the following setup-data.yaml file snippet:
#####################################################
# AutoBackup configuration
#####################################################
#Default is True
#autobackup: True or False
238
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
Managing Backup and Restore Operations
Management Node Auto-backup
The following tables shows when an auto-backup is performed during update or rollback or commit.
POD operation Auto-backup performed
Update
Rollback
Commit
Update fail with auto rollback
No
No
Yes
No
After successful auto-backup directory creation, user can copy it to an external server for later restoration as mentioned in
Restoring the Management Node .
During the auto backup, if Forwarding ELK logs to External Syslog server option is enabled, the
ElasticSearch database will not be maintained and the ELK logs will not be recovered after restoring the management node.
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
239
Management Node Auto-backup
Managing Backup and Restore Operations
240
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
C H A P T E R
13
Troubleshooting
•
Displaying Cisco NFVI Node Names and IP Addresses, page 241
•
Verifying Cisco NFVI Node Interface Configurations, page 242
•
Displaying Cisco NFVI Node Network Configuration Files, page 244
•
Viewing Cisco NFVI Node Interface Bond Configuration Files, page 244
•
Viewing Cisco NFVI Node Route Information, page 245
•
Viewing Linux Network Namespace Route Information, page 246
•
Prior to Remove Storage Operation, page 246
•
Troubleshooting Cisco NFVI, page 247
•
Management Node Recovery Scenarios, page 249
•
Recovering Compute Node Scenario, page 257
•
Running the Cisco VIM Technical Support Tool, page 259
•
Tech-support configuration file, page 260
•
Tech-support when servers are offline, page 262
•
Disk-maintenance tool to manage HDDs, page 263
•
OSD-maintenance tool, page 268
•
Utility to resolve Cisco VIM Hardware Validation Failures, page 273
Displaying Cisco NFVI Node Names and IP Addresses
Complete the following steps to display the Cisco NFVI node names and IP addresses.
Procedure
Step 1 Log into the Cisco NFVI build node.
Step 2 Display the openstack-configs/mercury_servers_info file.
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
241
Troubleshooting
Verifying Cisco NFVI Node Interface Configurations
The info files displays node name and address similar to the following:
# more openstack-configs/mercury_servers_info
Total nodes: 5
Controller nodes: 3
+------------------+--------------+--------------+--------------+-----------------+---------+
| Server
|
| CIMC | Management | Provision | Tenant | Storage
+------------------+--------------+--------------+--------------+-----------------+---------+
| test-c-control-1 | 10.10.223.13 | 10.11.223.22 | 10.11.223.22 | 169.254.133.102 | None
|
| | | | | |
|
| test-c-control-3 | 10.10.223.9
| 10.11.223.23 | 10.11.223.23 | 169.254.133.103 | None
|
| | | | | |
|
| test-c-control-2 | 10.10.223.10 | 10.11.223.24 | 10.11.223.24 | 169.254.133.104 | None
|
| | | | | |
|
+------------------+--------------+--------------+--------------+-----------------+---------+
Compute nodes: 2
+------------------+--------------+--------------+--------------+-----------------+---------+
|
|
Server | CIMC | Management | Provision | Tenant | Storage
+------------------+--------------+--------------+--------------+-----------------+---------+
| test-c-compute-1 | 10.10.223.11 | 10.11.223.25 | 10.11.223.25 | 169.254.133.105 | None
|
| | | | | |
|
| test-c-compute-2 | 10.10.223.12 | 10.11.223.26 | 10.11.223.26 | 169.254.133.106 | None
|
| | | | | |
|
+
Note During the Cisco NFVI deployment, SSH public keys for each node are added to
.../.ssh/authorized_keys, so you should be able to log in from the build node into each of the Cisco
NFVI nodes without passwords. If, for some reason you do need account information, see the openstack-configs/secrets.yaml file on the build node.
Verifying Cisco NFVI Node Interface Configurations
Complete the following steps to verify the interface configurations of Cisco NFVI nodes:
Procedure
Step 1 SSH into the target node, for example, one of the Cisco VIM controllers:
[root@ j11-build-1~]# ssh root@j11-control-server-1
[root@j11-control-server-1 ~]#
242
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
Troubleshooting
Verifying Cisco NFVI Node Interface Configurations
Step 2 Enter the ip a command to get a list of all interfaces on the node:
[root@j11-control-server-1 ~]# ip a
1: lo: <LOOPBACK,UP,LOWER_UP> mtu 65536 qdisc noqueue state UNKNOWN link/loopback 00:00:00:00:00:00 brd 00:00:00:00:00:00 inet 127.0.0.1/8 scope host lo valid_lft forever preferred_lft forever
2: enp8s0: <BROADCAST,MULTICAST,UP,LOWER_UP> mtu 1500 qdisc mq state UP qlen 1000 link/ether 54:a2:74:7d:42:1d brd ff:ff:ff:ff:ff:ff
3: enp9s0: <BROADCAST,MULTICAST,UP,LOWER_UP> mtu 1500 qdisc mq state UP qlen 1000 link/ether 54:a2:74:7d:42:1e brd ff:ff:ff:ff:ff:ff
4: mx0: <BROADCAST,MULTICAST,SLAVE,UP,LOWER_UP> mtu 1500 qdisc mq master mx state UP qlen
1000 link/ether 54:a2:74:7d:42:21 brd ff:ff:ff:ff:ff:ff
5: mx1: <BROADCAST,MULTICAST,SLAVE,UP,LOWER_UP> mtu 1500 qdisc mq master mx state UP qlen
1000 link/ether 54:a2:74:7d:42:21 brd ff:ff:ff:ff:ff:ff
6: t0: <BROADCAST,MULTICAST,SLAVE,UP,LOWER_UP> mtu 1500 qdisc mq master t state UP qlen
1000 link/ether 54:a2:74:7d:42:23 brd ff:ff:ff:ff:ff:ff
7: t1: <BROADCAST,MULTICAST,SLAVE,UP,LOWER_UP> mtu 1500 qdisc mq master t state UP qlen
1000 link/ether 54:a2:74:7d:42:23 brd ff:ff:ff:ff:ff:ff
8: e0: <BROADCAST,MULTICAST,SLAVE,UP,LOWER_UP> mtu 1500 qdisc mq master e state UP qlen
1000 link/ether 54:a2:74:7d:42:25 brd ff:ff:ff:ff:ff:ff
9: e1: <BROADCAST,MULTICAST,SLAVE,UP,LOWER_UP> mtu 1500 qdisc mq master e state UP qlen
1000 link/ether 54:a2:74:7d:42:25 brd ff:ff:ff:ff:ff:ff
10: p0: <BROADCAST,MULTICAST,SLAVE,UP,LOWER_UP> mtu 1500 qdisc mq master p state UP qlen
1000 link/ether 54:a2:74:7d:42:27 brd ff:ff:ff:ff:ff:ff
11: p1: <BROADCAST,MULTICAST,SLAVE,UP,LOWER_UP> mtu 1500 qdisc mq master p state UP qlen
1000 link/ether 54:a2:74:7d:42:27 brd ff:ff:ff:ff:ff:ff
12: a0: <BROADCAST,MULTICAST,SLAVE,UP,LOWER_UP> mtu 1500 qdisc mq master a state UP qlen
1000 link/ether 54:a2:74:7d:42:29 brd ff:ff:ff:ff:ff:ff
13: a1: <BROADCAST,MULTICAST,SLAVE,UP,LOWER_UP> mtu 1500 qdisc mq master a state UP qlen
1000 link/ether 54:a2:74:7d:42:29 brd ff:ff:ff:ff:ff:ff
14: bond0: <BROADCAST,MULTICAST,MASTER> mtu 1500 qdisc noop state DOWN link/ether 4a:2e:2a:9e:01:d1 brd ff:ff:ff:ff:ff:ff
15: a: <BROADCAST,MULTICAST,MASTER,UP,LOWER_UP> mtu 1500 qdisc noqueue master br_api state
UP link/ether 54:a2:74:7d:42:29 brd ff:ff:ff:ff:ff:ff
16: br_api: <BROADCAST,MULTICAST,UP,LOWER_UP> mtu 1500 qdisc noqueue state UP link/ether 54:a2:74:7d:42:29 brd ff:ff:ff:ff:ff:ff
17: e: <BROADCAST,MULTICAST,MASTER,UP,LOWER_UP> mtu 1500 qdisc noqueue state UP link/ether 54:a2:74:7d:42:25 brd ff:ff:ff:ff:ff:ff
18: mx: <BROADCAST,MULTICAST,MASTER,UP,LOWER_UP> mtu 1500 qdisc noqueue master br_mgmt state
UP link/ether 54:a2:74:7d:42:21 brd ff:ff:ff:ff:ff:ff
19: br_mgmt: <BROADCAST,MULTICAST,UP,LOWER_UP> mtu 1500 qdisc noqueue state UP link/ether 54:a2:74:7d:42:21 brd ff:ff:ff:ff:ff:ff inet 10.23.221.41/28 brd 10.23.221.47 scope global br_mgmt
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
243
Troubleshooting
Displaying Cisco NFVI Node Network Configuration Files valid_lft forever preferred_lft forever
20: p: <BROADCAST,MULTICAST,MASTER,UP,LOWER_UP> mtu 1500 qdisc noqueue state UP link/ether 54:a2:74:7d:42:27 brd ff:ff:ff:ff:ff:ff
21: t: <BROADCAST,MULTICAST,MASTER,UP,LOWER_UP> mtu 1500 qdisc noqueue state UP link/ether 54:a2:74:7d:42:23 brd ff:ff:ff:ff:ff:ff inet 17.16.3.8/24 brd 17.16.3.255 scope global t valid_lft forever preferred_lft forever
22: docker0: <NO-CARRIER,BROADCAST,MULTICAST,UP> mtu 1500 qdisc noqueue state DOWN link/ether 02:42:70:f6:8b:da brd ff:ff:ff:ff:ff:ff inet 172.17.42.1/16 scope global docker0 valid_lft forever preferred_lft forever
24: mgmt-out@if23: <BROADCAST,MULTICAST,UP,LOWER_UP> mtu 1500 qdisc pfifo_fast master br_mgmt state UP qlen 1000 link/ether 5a:73:51:af:e5:e7 brd ff:ff:ff:ff:ff:ff link-netnsid 0
26: api-out@if25: <BROADCAST,MULTICAST,UP,LOWER_UP> mtu 1500 qdisc pfifo_fast master br_api state UP qlen 1000 link/ether 6a:a6:fd:70:01:f9 brd ff:ff:ff:ff:ff:ff link-netnsid 0
Displaying Cisco NFVI Node Network Configuration Files
Complete the following steps to view a Cisco NFVI node network configuration files:
Procedure
Step 1 SSH into the target node, for example, one of the Cisco VIM controllers:
[root@ j11-build-1~]# ssh root@j11-control-server-1
[root@j11-control-server-1 ~]#
Step 2 List all of the network configuration files in the /etc/sysconfig/network-scripts directory, for example:
[root@j11-control-server-1 ~]# ls /etc/sysconfig/network-scripts/ ifcfg-a ifcfg-a0 ifcfg-enp15s0 ifcfg-mx0 ifcfg-enp16s0 ifcfg-mx1 ifcfg-a1 ifcfg-enp17s0 ifcfg-p ifcfg-br_api ifcfg-enp18s0 ifcfg-p0 ifcfg-br_mgmt ifcfg-enp19s0 ifcfg-p1 ifcfg-e ifcfg-enp20s0 ifcfg-t ifcfg-e0 ifcfg-e1 ifcfg-enp21s0 ifcfg-enp8s0 ifcfg-t0 ifcfg-t1 ifdown-routes ifdown-sit ifup-ipv6 ifup-isdn ifcfg-enp12s0 ifcfg-enp9s0 ifdown ifcfg-enp13s0 ifcfg-lo ifdown-bnep ifdown-Team ifdown-TeamPort ifup-plip ifup-plusb network-functions-ipv6 ifcfg-enp14s0 ifcfg-mx ifdown-eth ifdown-ib ifdown-ippp ifdown-ipv6 ifdown-isdn ifdown-post ifdown-ppp ifdown-tunnel ifup ifup-ppp ifup-aliases ifup-routes ifup-bnep ifup-eth ifup-ib ifup-ippp ifup-sit ifup-Team ifup-TeamPort ifup-tunnel ifup-post ifup-wireless init.ipv6-global network-functions
Viewing Cisco NFVI Node Interface Bond Configuration Files
Complete the following steps to view the Cisco NFVI node interface bond configuration files:
244
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
Troubleshooting
Viewing Cisco NFVI Node Route Information
Procedure
Step 1 SSH into the target node, for example, one of the Cisco VIM controllers:
[root@ j11-build-1~]# ssh root@j11-control-server-1
[root@j11-control-server-1 ~]#
Step 2 List all of the network bond configuration files in the /proc/net/bonding/ directory:
[root@j11-control-server-1 ~]# ls /proc/net/bonding/ a bond0 e mx p t
Step 3 To view more information about a particular bond configuration, enter:
[root@j11-control-server-1 ~]# more /proc/net/bonding/a
Ethernet Channel Bonding Driver: v3.7.1 (April 27, 2011)
Bonding Mode: load balancing (xor)
Transmit Hash Policy: layer3+4 (1)
MII Status: up
MII Polling Interval (ms): 100
Up Delay (ms): 0
Down Delay (ms): 0
Slave Interface: a0
MII Status: up
Speed: 10000 Mbps
Duplex: full
Link Failure Count: 1
Permanent HW addr: 54:a2:74:7d:42:29
Slave queue ID: 0
Slave Interface: a1
MII Status: up
Speed: 10000 Mbps
Duplex: full
Link Failure Count: 2
Permanent HW addr: 54:a2:74:7d:42:2a
Slave queue ID: 0
Viewing Cisco NFVI Node Route Information
Complete the following steps to view Cisco NFVI node route information. Note that this is not the HAProxy container running on the controller. The default gateway should point to the gateway on the management network using the br_mgmt bridge.
Procedure
Step 1 SSH into the target node, for example, one of the Cisco VIM controllers:
[root@ j11-build-1~]# ssh root@j11-control-server-1
[root@j11-control-server-1 ~]#
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
245
Troubleshooting
Viewing Linux Network Namespace Route Information
Step 2 View the routing table (verify the default gateway) of the Cisco NFVI node:
[root@j11-control-server-1 ~]# route -n
Kernel IP routing table
Destination
0.0.0.0
10.23.221.32
17.16.3.0
169.254.0.0
169.254.0.0
169.254.0.0
169.254.0.0
169.254.0.0
172.17.0.0
Gateway
10.23.221.33
0.0.0.0
0.0.0.0
0.0.0.0
0.0.0.0
0.0.0.0
0.0.0.0
0.0.0.0
0.0.0.0
Genmask
0.0.0.0
255.255.255.240 U
255.255.255.0
U
Flags Metric Ref
UG 0 0
0
0
0
0
255.255.0.0
255.255.0.0
255.255.0.0
255.255.0.0
255.255.0.0
255.255.0.0
U
U
U
U
U
U
1016
1017
1019
1020
1021
0
0
0
0
0
0
0
Use Iface
0 br_mgmt
0 br_mgmt
0 t
0 br_api
0 e
0 br_mgmt
0 p
0 t
0 docker0
Viewing Linux Network Namespace Route Information
Complete the following steps to view the route information of the Linux network namespace that the HAProxy container uses on a Cisco NFVI controller node. The default gateway should point to the gateway on the API network using the API interface in the Linux network namespace.
Procedure
Step 1 SSH into the target node, for example, one of the Cisco VIM controllers:
[root@ j11-build-1~]# ssh root@j11-control-server-1
[root@j11-control-server-1 ~]#
Step 2 Enter the ip netns command to find the name of the network namespace:
[root@j11-control-server-2 ~]# ip netns 17550 (id: 0)
Step 3 Enter the ip netns exec command to view the routing table (verify the default gateway) of the Linux network namespace:
[root@j11-control-server-2 ~]# ip netns exec 17550 route -n
Kernel IP routing table
Destination
0.0.0.0
10.23.221.32
172.29.86.0
Gateway
172.29.86.1
0.0.0.0
0.0.0.0
Genmask Flags Metric Ref
0.0.0.0
UG
255.255.255.240 U
255.255.255.0
U
0
0
0
0
0
0
Use Iface
0 api
0 mgmt
0 api
Prior to Remove Storage Operation
Upon completion of the pod management operations such as add-storage, the operator needs to ensure that any subsequent operation such as remove-storage on the same storage node is done after accounting for all of the devices and their corresponding OSDs have been marked in the persistent crush map as shown in the output of the ceph osd crush tree.
246
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
Troubleshooting
Troubleshooting Cisco NFVI
Execute the following command on the storage node where a remove-storage pod operation is performed, to get a list of all the devices configured for ceph osds:
[root@storage-3 ~]$ df | grep -oh ceph-[0-9]*
[root@storage-3 ~]$ df | grep -oh ceph-[0-9]* ceph-1 ceph-5 ceph-7 ceph-10
Login to any of the controller nodes and run the following commands within the ceph mon container:
$ cephmon
$ ceph osd crush tree
From the json output, locate the storage node to be removed and ensure all of the devices listed for ceph osds have corresponding osd entries for them by running the following commands:
{
"id": -3,
"name": "storage-3",
"type": "host",
"type_id": 1,
"items": [
{
"id": 1,
"name": "osd.1",
"type": "osd",
"type_id": 0,
"crush_weight": 1.091095,
"depth": 2
},
{
"id": 5,
"name": "osd.5",
"type": "osd",
"type_id": 0,
"crush_weight": 1.091095,
"depth": 2
},
{
"id": 7,
"name": "osd.7",
"type": "osd",
"type_id": 0,
"crush_weight": 1.091095,
"depth": 2
},
{
"id": 10,
"name": "osd.10",
"type": "osd",
"type_id": 0,
"crush_weight": 1.091095,
"depth": 2
}
]
},
Troubleshooting Cisco NFVI
The following topics provide Cisco NFVI general troubleshooting procedures.
Container Download Problems
1 Check installer logs log file /var/log/mercury/mercury_buildorchestration.log for any build node orchestration failures including stuck "registry-Populate local registry". In some cases, the Docker container download from your management node might be slow.
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
247
Troubleshooting
Troubleshooting Cisco NFVI
2 Check the network connectivity between the management node and the remote registry in defaults.yaml
on the management node (grep "^registry:" openstack-configs/defaults.yaml).
3 Verify valid remote registry credentials are defined in setup_data.yaml file.
4 A proxy server might be needed to pull the container images from remote registry. If a proxy is required, exclude all IP addresses for your setup including management node.
PXE Boot Problems
1 Check log file /var/log/mercury/mercury_baremetal_install.log and connect to failing node CIMC KVM console to find out more on PXE boot failure reason.
2 Ensure all validations (step 1) and hardware validations (step 3) pass.
3 Check the kickstart file used in setup_data.yaml for controller, compute, and storage nodes and that matches with the hardware of corresponding nodes.
4 Check the Cobbler web interface to see all the configured systems got populated: https://<management_node_ip>/cobbler_web/system/list username:
[ cobbler password ]: grep COBBLER ~/openstack-configs/secrets.yaml | awk -F":" '{print
$2}'
5 Check that the gateway of management/provision network is not the same as that of management interface
IP address of the management node.
6 Check L2/L3 network connectivity between the failing node and the management node. Also, check the
VPC configuration and port-channel status.
7 Check that the actual PXE boot order is not different from the configured boot-order.
8 Check that PXE (DHCP/TFTP) packets arrive at the management node by performing tcpdump on management interface and looking for UDP 67 or UDP 69 port.
9 Check that HTTP request reaches management node by performing tcpdump on management node management interface on TCP 80 and TCP 443 port. Also check the Docker logs for HTTP request from the failing node: docker exec -it repo_mirror tail -f /var/log/httpd/access_log.
10 Verify all nodes are running on supported Cisco NFVI CIMC firmware or above.
11 Verify supported VIC cards are installed (UCS C-series 1225/1227; UCS B-series: 1240/1280/1340/1380).
12 There are times (especially on redeployment) when the overcloud nodes (controller or compute) for some reason do not get their boot order set correctly even though CIMC says the order is correct. In such instances step 4 of runner fails as PXE boot never completes in time. The workaround is to manually enter the boot menu from the KVM console of the affected nodes and make sure the correct order (NIC interface) is chosen for the PXE boot. Note: the solution is likely to clear the BIOS CMOS before PXE booting. Will confirm if this solves the problem to avoid waiting on the KVM console at the time of PXE booting
Cisco IMC Connection Problems during Bare Metal Installation
The likely cause is Cisco IMC has too many connections, so the installer cannot connect to it. Clear the connections by logging into your Cisco IMC, going into the Admin->Sessions tab and clearing the connections.
API VIP Connection Problems
Verify the active HAProxy container is running in one of the controller nodes. On that controller within the
HAProxy container namespace verify the IP address is assigned to the API interface. Also, verify that your
ToR and the network infrastructure connecting your ToR is provisioned with API network segment VLAN.
HAProxy Services Downtime after Initial Installation or HA Failover
248
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
Troubleshooting
Management Node Recovery Scenarios
The HAProxy web interface can be accessed on TCP port 1936 http://<external_lb_vip_address>:1936/
Username: haproxy
Password: <HAPROXY_PASSWORD> from secrets.yaml file
After initial installation, the HAProxy web interface might report several OpenStack services with downtime depending upon when that OpenStack service was installed after HAProxy install. The counters are not synchronized between HAProxy active and standby. After HA proxy failover, the downtime timers might change based on the uptime of new active HAproxy container.
Management Node Problems
Service Commands
To identify all the services that are running, enter:
$ systemctl -a | grep docker | grep service
On controller ignore status of: docker-neutronlb
On compute ignore status of: docker-neutronlb, docker-keystone
To start a service on a host, enter:
$ systemctl start <service_name>
To stop a service on a host, enter:
$ systemctl stop <service_name>
To restart a service on a host, enter:
$ systemctl restart <service_name>
To check service status on a host, enter:
$ systemctl status <service_name>
Management Node Recovery Scenarios
The Cisco NFVI management node hosts the Cisco VIM Rest API service, Cobbler for PXE services, ELK for Logging/Kibana dashboard services and VMTP for cloud validation. Because the maintenance node currently does not have redundancy, understanding its points of failure and recovery scenarios is important.
These are described in this topic.
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
249
Troubleshooting
Management Node Recovery Scenarios
The management node architecture includes a Cisco UCS C240 M4 server with dual CPU socket. It has a 1
Gbps on-board (LOM) NIC and a 10 Gbps Cisco VIC mLOM. HDDs are used in 8,16, or 24 disk configurations.
The following figure shows a high level maintenance node hardware and software architecture.
Figure 26: Cisco NFVI Management Node Architecture
Different management node hardware or software failures can cause Cisco NFVI service disruptions and outages. Some failed services can be recovered through manual intervention. In cases where the system is operational during a failure, double faults might not be recoverable. The following table lists different management node failure scenarios and their recovery options.
Table 3: Management Node Failure Scenarios
Scenario #
1
Failure/Trigger
Failure of 1 or 2 active HDD
Recoverable?
Yes
Operational Impact
No
250
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
Troubleshooting
Management Node Recovery Scenarios
17
18
15
16
10
11
8
9
4
5
6
7
Scenario #
2
Failure/Trigger
Simultaneous failure of more than 2 active HDD
Recoverable?
No
3 Spare HDD failure: 4 spare for 24
HDD; or 2 spare for 8 HDD
Yes
Power outage/hard reboot
Graceful reboot
Yes
Yes
Docker daemon start failure Yes
Service container (Cobbler, ELK) start failure
Yes
12
13
One link failure on bond interface
Two link failures on bond interface
REST API service failure
Graceful reboot with Cisco VIM
Insight
Yes
Yes
Yes
Yes
Power outage/hard reboot with Cisco
VIM Insight
Yes
VIM Insight Container reinstallation Yes
14 Cisco VIM Insight Container reboot Yes
Intel 1350 1Gbps LOM failure
Cisco VIC 1227 10 Gbps mLOM failure
DIMM memory failure
One CPU failure
Yes
Yes
Yes
Yes
Scenario 1: Failure of one or two active HDDs
The management node has either 8,16, or 24 HDDs. The HDDs are configured with RAID 6, which helps enable data redundancy and storage performance and overcomes any unforeseen HDD failures.
• When 8 HDDs are installed, 7 are active disks and one is spare disk.
Operational Impact
Yes
No
Yes
Yes
Yes
Yes
No
Yes
No
Yes; CLI alternatives exist during reboot.
Yes
Yes; CLI alternatives exist during re-insight.
Yes; CLI alternatives exist during reboot.
Yes
Yes
No
No
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
251
Troubleshooting
Management Node Recovery Scenarios
• When 16 HDDs are installed, 14 are active disks and two are spare disks.
• When 24 HDDs are installed, 20 are active disks and four are spare disks.
With RAID 6 up to two simultaneous active HDD failures can occur. When an HDD fails, the system starts automatic recovery by moving the spare disk to active state and starts recovering and rebuilding the new active
HDD. It takes approximately four hours to rebuild the new disk and move to synchronized state. During this operation, the system is completely functional and no impacts are seen. However, you must monitor the system to ensure that additional failures do not occur to enter into a double fault situation.
You can use the storcli commands to check the disk and RAID state as shown below:
Note Make sure the node is running with hardware RAID by checking the storcli output and comparing to the one preceding.
[root@mgmt-node ~]# /opt/MegaRAID/storcli/storcli64 /c0 show
< … snip … >
TOPOLOGY:
========
-----------------------------------------------------------------------------
DG Arr Row EID:Slot DID Type State BT Size PDC PI SED DS3 FSpace TR
-----------------------------------------------------------------------------
0 -
0 0 -
6 in optimal state
RAID6 Optl N
RAID6 Optl N
4.087 TB dflt N
4.087 TB dflt N
N
N dflt N dflt N
N
N
0 0 0 252:1
0 0 1 252:2
1 DRIVE Onln N 837.258 GB dflt N N dflt -
2 DRIVE Onln N 837.258 GB dflt N N dflt -
N
N
0 0 2 252:3
0 0 3 252:4
0 0 4 252:5
0 0 5 252:6
0 0 6 252:7
0 252:8
3
4
5
DRIVE Onln
DRIVE Onln
DRIVE Onln
N
N
N
930.390 GB dflt N
930.390 GB dflt N
930.390 GB dflt N
N
N
N dflt dflt dflt -
6 DRIVE Onln N 930.390 GB dflt N N dflt -
7 DRIVE Onln N 930.390 GB dflt N N dflt -
8 DRIVE DHS 930.390 GB -
N
N
N
N
N
N
<== RAID
-----------------------------------------------------------------------------
< … snip … >
PD LIST:
=======
-------------------------------------------------------------------------
EID:Slt DID State DG Size Intf Med SED PI SeSz Model Sp
-------------------------------------------------------------------------
252:1 1 Onln functioning
0 837.258 GB SAS HDD N N 512B ST900MM0006 U <== all disks
252:2
252:3
252:4
252:5
2 Onln
3 Onln
4 Onln
5 Onln
0 837.258 GB SAS
0 930.390 GB SAS
0 930.390 GB SAS
0 930.390 GB SAS
HDD N
HDD N
HDD N
HDD N
N
N
N
N
512B ST900MM0006
512B ST91000640SS
512B ST91000640SS
512B ST91000640SS
U
U
U
U
252:6
252:7
6 Onln
7 Onln
0 930.390 GB SAS
0 930.390 GB SAS
HDD N
HDD N
N
N
512B ST91000640SS
512B ST91000640SS
U
U
252:8 8 DHS 0 930.390 GB SAS HDD N N 512B ST91000640SS D
-------------------------------------------------------------------------
[root@mgmt-node ~]# /opt/MegaRAID/storcli/storcli64 /c0 show
< … snip … >
TOPOLOGY :
========
-----------------------------------------------------------------------------
DG Arr Row EID:Slot DID Type State BT Size PDC PI SED DS3 FSpace TR
-----------------------------------------------------------------------------
252
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
Troubleshooting
Management Node Recovery Scenarios
0 in degraded state
0 0
0 0
0 0
-
0
1
-
252:8
252:2
RAID6 Pdgd N 4.087 TB dflt N N dflt N
RAID6 Dgrd N 4.087 TB dflt N N dflt N
8 DRIVE Rbld Y 930.390 GB dflt N N dflt -
2 DRIVE Onln N 837.258 GB dflt N N dflt -
N
N
N
N
0 0 2 252:3
0 0 3 252:4
0 0 4 252:5
0 0 5 252:6
3
4
5
6
DRIVE Onln
DRIVE Onln
DRIVE Onln
DRIVE Onln
N
N
N
N
930.390 GB dflt N
930.390 GB dflt N
930.390 GB dflt N
930.390 GB dflt N
N
N
N
N dflt dflt dflt dflt -
N
N
N
N
0 0 6 252:7 7 DRIVE Onln N 930.390 GB dflt N N dflt N
-----------------------------------------------------------------------------
<== RAID 6
< … snip … >
PD LIST :
=======
-------------------------------------------------------------------------
EID:Slt DID State DG Size Intf Med SED PI SeSz Model Sp
-------------------------------------------------------------------------
252:1 1 UGood 837.258 GB SAS HDD N N 512B ST900MM0006 U in slot 1 disconnected from drive group 0
252:2 2 Onln 0 837.258 GB SAS HDD N N 512B ST900MM0006
252:3
252:4
252:5
3 Onln
4 Onln
5 Onln
0
0
0
930.390 GB SAS
930.390 GB SAS
930.390 GB SAS
HDD N
HDD N
HDD N
N
N
N
512B ST91000640SS
512B ST91000640SS
512B ST91000640SS
U
U
U
U
252:6
252:7
6 Onln 0 930.390 GB SAS HDD N N 512B ST91000640SS
7 Onln 0 930.390 GB SAS HDD N N 512B ST91000640SS
252:8 8 Rbld 0 930.390 GB SAS HDD N N 512B ST91000640SS in slot 8 joined drive group 0 and in rebuilding state
U
U
U
-------------------------------------------------------------------------
<== active disk
<== spare disk
[root@mgmt-node ~]# /opt/MegaRAID/storcli/storcli64 /c0/e252/s8 show rebuild
Controller = 0
Status = Success
Description = Show Drive Rebuild Status Succeeded.
------------------------------------------------------
Drive-ID Progress% Status Estimated Time Left
------------------------------------------------------
/c0/e252/s8 20 In progress 2 Hours 28 Minutes status
------------------------------------------------------
<== spare disk in slot 8 rebuild
To replace the failed disk and add it back as a spare:
[root@mgmt-node ~]# /opt/MegaRAID/storcli/storcli64 /c0/e252/s1 add hotsparedrive dg=0
Controller = 0
Status = Success
Description = Add Hot Spare Succeeded.
[root@mgmt-node ~]# /opt/MegaRAID/storcli/storcli64 /c0 show
< … snip … >
TOPOLOGY :
========
-----------------------------------------------------------------------------
DG Arr Row EID:Slot DID Type State BT Size PDC PI SED DS3 FSpace TR
-----------------------------------------------------------------------------
0 RAID6 Pdgd N 4.087 TB dflt N N dflt N N
0 0 -
0 0 0 252:8
0 0 1 252:2
-
8
2
RAID6 Dgrd
DRIVE Rbld
DRIVE Onln
N
Y
N
4.087 TB dflt N
930.390 GB dflt N
837.258 GB dflt N
N
N
N dflt N dflt dflt -
N
N
N
0 0 2 252:3
0 0 3 252:4
0 0 4 252:5
0 0 5 252:6
0 0 6 252:7
0 252:1
3 DRIVE Onln N 930.390 GB dflt N N dflt -
4 DRIVE Onln N 930.390 GB dflt N N dflt -
5 DRIVE Onln N 930.390 GB dflt N N dflt -
6 DRIVE Onln N 930.390 GB dflt N N dflt -
7 DRIVE Onln N 930.390 GB dflt N N dflt -
1 DRIVE DHS 837.258 GB -
N
N
N
N
N
N
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
253
Troubleshooting
Management Node Recovery Scenarios
-----------------------------------------------------------------------------
< … snip … >
PD LIST :
=======
-------------------------------------------------------------------------
EID:Slt DID State DG Size Intf Med SED PI SeSz Model Sp
-------------------------------------------------------------------------
252:1 1 DHS 0 837.258 GB SAS HDD N N 512B ST900MM0006 U disk added back as spare
252:2
252:3
252:4
252:5
252:6
252:7
2 Onln
3 Onln
4 Onln
5 Onln
6 Onln
7 Onln
0
0
0
0
0
0
837.258 GB SAS
930.390 GB SAS
930.390 GB SAS
930.390 GB SAS
930.390 GB SAS
930.390 GB SAS
HDD N
HDD N
HDD N
HDD N
HDD N
HDD N
N
N
N
N
N
N
512B ST900MM0006
512B ST91000640SS
512B ST91000640SS
512B ST91000640SS
512B ST91000640SS
512B ST91000640SS
U
U
U
U
U
U
252:8 8 Rbld 0 930.390 GB SAS HDD N N 512B ST91000640SS U
-------------------------------------------------------------------------
Scenario 2: Simultaneous failure of more than two active HDDs
<== replacement
If more than two HDD failures occur at the same time, the management node goes into an unrecoverable failure state because RAID 6 allows for recovery of up to two simultaneous HDD failures. To recover the management node, reinstall the operating system.
Scenario 3: Spare HDD failure
When the management node has 24 HDDs, four are designated as spares. Failure of any of the disks does not impact the RAID or system functionality. Cisco recommends replacing these disks when they fail (see the steps in Scenario 1) to serve as standby disks and so when an active disk fails, an auto-rebuild is triggered.
Scenario 4: Power outage/hard reboot
If a power outage or hard system reboot occurs, the system will boot up and come back to operational state.
Services running on management node during down time will be disrupted. See the steps in Scenario 9 for the list of commands to check the services status after recovery.
Scenario 5: System reboot
If a graceful system reboot occurs, the system will boot up and come back to operational state. Services running on management node during down time will be disrupted. See the steps in Scenario 9 for the list of commands to check the services status after recovery.
Scenario 6: Docker daemon start failure
The management node runs the services using Docker containers. If the Docker daemon fails to come up, it causes services such as ELK, Cobbler and VMTP to go into down state. You can use the systemctl command to check the status of the Docker daemon, for example:
# systemctl status docker docker.service - Docker Application Container Engine
Loaded: loaded (/usr/lib/systemd/system/docker.service; enabled; vendor preset: disabled)
Active: active (running) since Mon 2016-08-22 00:33:43 CEST; 21h ago
Docs: http://docs.docker.com
Main PID: 16728 (docker)
If the Docker daemon is in down state, use the systemctl restart docker command to restart the Docker service. Run the commands listed in Scenario 9 to verify that all the Docker services are active.
Scenario 7: Service container (Cobbler, ELK) start failure
As described in Scenario 8, all the services run as Docker containers on the management node. To find all services running as containers, use the docker ps – a command. If any services are in Exit state, use the systemctl command and grep for Docker to find the exact service name, for example:
# systemctl | grep docker- | awk '{print $1}' docker-cobbler-tftp.service
docker-cobbler-web.service
254
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
Troubleshooting
Management Node Recovery Scenarios docker-cobbler.service
docker-container-registry.service
docker-elasticsearch.service
docker-kibana.service
docker-logstash.service
docker-vmtp.service
If any services need restarting, use the systemctl command. For example, to restart a Kibana service:
# systemctl restart docker-kibana.service
Scenario 8: One link failure on the bond Interface
The management node is set up with two different networks: br_api and br_mgmt. The br_api interface is the external. It is used for accessing outside services such as the Cisco VIM REST API, Kibana and Cobbler. The br_mgmt interface is internal. It is used for provisioning and to provide management connectivity to all
OpenStack nodes (control, compute and storage). Each network has two ports that are bonded to provide redundancy. If one port fails, the system will remain completely functional through the other port. If a port fails, check for physical network connectivity and/or remote switch configuration to debug the underlying cause of the link failure.
Scenario 9: Two link failures on the bond Interface
As described in Scenario 10, each network is configured with two ports. If both ports are down, the system is not reachable and management node services could be disrupted. After the ports are back up, the system is fully operational. Check the physical network connectivity and/or the remote switch configuration to debug the underlying link failure cause.
Scenario 10: REST API service failure
The management node runs the REST API service for Cisco VIM clients to reach the server. If the REST service is down, Cisco VIM clients cannot reach the server to trigger any server operations. However, with the exception of the REST service, other management node services remain operational.
To verify the management node REST services are fully operational, use the following command to check that the httpd and mercury-restapi services are in active and running state:
# systemctl status httpd httpd.service - The Apache HTTP Server
Loaded: loaded (/usr/lib/systemd/system/httpd.service; enabled; vendor preset: disabled)
Active: active (running) since Mon 2016-08-22 00:22:10 CEST; 22h ago
# systemctl status mercury-restapi.service
mercury-restapi.service - Mercury Restapi
Loaded: loaded (/usr/lib/systemd/system/mercury-restapi.service; enabled; vendor preset: disabled)
Active: active (running) since Mon 2016-08-22 00:20:18 CEST; 22h ago
A tool is also provided so that you can check the REST API server status and the location of the directory it is running from. To execute run the following command:
# cd installer-<tagid>/tools
#./restapi.py -a status
Status of the REST API Server: active (running) since Thu 2016-08-18 09:15:39 UTC; 9h ago
REST API launch directory: /root/installer-<tagid>/
Confirm the server status is active and check that the restapi launch directory matches the directory where the installation was launched. The restapi tool also provides the options to launch, tear down, and reset password for the restapi server as shown below:
# ./restapi.py
– h usage: restapi.py [-h] --action ACTION [--yes] [--verbose]
REST API setup helper optional arguments:
-h, --help show this help message and exit
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
255
Troubleshooting
Management Node Recovery Scenarios
--action ACTION, -a ACTION setup - Install and Start the REST API server.
teardown - Stop and Uninstall the REST API server.
restart - Restart the REST API server.
regenerate-password - Regenerate the password for
REST API server.
reset-password - Reset the REST API password with user given password.
--yes, -y
--verbose, -v status - Check the status of the REST API server
Skip the dialog. Yes to the action.
Perform the action in verbose mode.
If the REST API server is not running, execute ciscovim to show the following error message:
# cd installer-<tagid>/
# ciscovim -setupfile ~/Save/<setup_data.yaml> run
If the installer directory or the REST API state is not correct or points to an incorrect REST API launch directory, go to the installer-<tagid>/tools directory and execute:
# ./restapi.py
– action setup
To confirm that the REST API server state and launch directory is correct run the following command:
# ./restapi.py
– action status
Scenario 11: Graceful reboot with Cisco VIM Insight
Cisco VIM Insight runs as a container on the management node. After a graceful reboot of the management node, the VIM Insight and its associated database containers will come up. So there is no impact on recovery.
Scenario 12: Power outage or hard reboot with VIM Insight
The Cisco VIM Insight container will come up automatically following a power outage or hard reset of the management node.
Scenario 13: Cisco VIM Insight reinstallation
If the management node which is running the Cisco VIM Insight fails and cannot come up, you must uninstall and reinstall the Cisco VIM Insight. After the VM Insight container comes up, add the relevant bootstrap steps as listed in the install guide to register the pod. VIM Insight then automatically detects the installer status and reflects the current status appropriately.
To clean up and reinstall Cisco VIM Insight run the following command:
# cd /root/installer-<tagid>/insight/
# ./bootstrap_insight.py
– a uninstall – o standalone – f </root/insight_setup_data.yaml>
Scenario 14: VIM Insight Container reboot
On Reboot of the VIM Insight container, services will continue to work as it is.
Scenario 15: Intel (I350) 1Gbps LOM failure
The management node is set up with an Intel (I350) 1 Gbps LOM for API connectivity. Two 1 Gbps ports are bonded to provide connectivity redundancy. No operational impact occurs if one of these ports goes down.
However, if both ports fail, or the LOM network adapter fails, the system cannot be reached through the API
IP address. If this occurs you must replace the server because the LOM is connected to the system motherboard.
To recover the management node with a new server, complete the following steps. Make sure the new management node hardware profile matches the existing server and the Cisco IMC IP address is assigned.
1 Shut down the existing management node.
2 Unplug the power from the existing and new management nodes.
3 Remove all HDDs from existing management node and install them in the same slots of the new management node.
4 Plug in the power to the new management node, but do not boot the node.
256
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
Troubleshooting
Recovering Compute Node Scenario
5 Verify the configured boot order is set to boot from local HDD.
6 Verify the Cisco NFVI management VLAN is configured on the Cisco VIC interfaces.
7 Boot the management node for the operating system to start.
After the management node is up, the management node bond interface will be down due to the incorrect
MAC address on the ifcfg files. It will point to old node network card MAC address.
8 Update the MAC address on the ifcfg files under /etc/sysconfig/network-scripts.
9 Reboot the management node.
It will come up and be fully operational. All interfaces should be in an up state and be reachable.
10 Verify that Kibana and Cobbler dashboards are accessible.
11 Verify the Rest API services are up. See Scenario 15 for any recovery steps.
Scenario 16: Cisco VIC 1227 10Gbps mLOM failure
The management node is configured with a Cisco VIC 1227 dual port 10 Gbps mLOM adapter for connectivity to the other Cisco NFVI nodes. Two 10 Gbps ports are bonded to provide connectivity redundancy. If one of the 10 Gbps ports goes down, no operational impact occurs. However, if both Cisco VIC 10 Gbps ports fail, the system goes into an unreachable state on the management network. If this occurs, you must replace the
VIC network adapters. Otherwise pod management and the Fluentd forwarding service will be disrupted. If you replace a Cisco VIC, update the management and provisioning VLAN for the VIC interfaces using Cisco
IMC and update the MAC address in the interfaces under /etc/sysconfig/network-scripts interface configuration file.
Scenario 17: DIMM memory failure
The management node is set up with multiple DIMM memory across different slots. Failure of one or memory modules could cause the system to go into unstable state, depending on how many DIMM memory failures occur. DIMM memory failures are standard system failures like any other Linux system server. If a DIMM memory fails, replace the memory module(s) as soon as possible to keep the system in stable state.
Scenario 18: One CPU failure
Cisco NFVI management nodes have dual core Intel CPUs (CPU1 and CPU2). If one CPU fails, the system remains operational. However, always replace failed CPU modules immediately. CPU failures are standard system failures like any other Linux system server. If a CPU fails, replace it immediately to keep the system in stable state.
Recovering Compute Node Scenario
The Cisco NFVI Compute node hosts the OpenStack services to provide processing, network, and storage resources to run instances. The node architecture includes a Cisco UCS C220 M4 server with dual CPU socket,
10 Gbps Cisco VIC mLOM, and two HDDs in RAID 1 configuration.
Failure of one active HDD
With RAID 1, data are mirrored and can allow up to one active HDD failure. When a HDD fails, the node is still functional with no impacts. However, the data are no longer mirrored and losing another HDD will result in unrecoverable and operational downtime. The failed disk should be replaced soon as it takes approximately two hours to rebuild the new disk and move to synchronized state.
To check the disk and RAID state run the storcli commands as follows:
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
257
Troubleshooting
Recovering Compute Node Scenario
Note Make sure that the node is running with hardware RAID by checking the storcli output and comparing to the one below.
[root@compute-node ~]# /opt/MegaRAID/storcli/storcli64 /c0 show
< … snip … >
TOPOLOGY :
========
-----------------------------------------------------------------------------
DG Arr Row EID:Slot DID Type State BT Size PDC PI SED DS3 FSpace TR
-----------------------------------------------------------------------------
0 optimal state
RAID1 Optl N 837.258 GB dflt N N dflt N N <== RAID 1 in
0 0 -
0 0 0 252:2
RAID1 Optl N 837.258 GB dflt N N dflt N
9 DRIVE Onln N 837.258 GB dflt N N dflt -
N
N
0 0 1 252:3 11 DRIVE Onln N 837.258 GB dflt N N dflt N
-----------------------------------------------------------------------------
< … snip … >
Physical Drives = 2
PD LIST :
=======
-------------------------------------------------------------------------
EID:Slt DID State DG Size Intf Med SED PI SeSz Model Sp
-------------------------------------------------------------------------
252:2 9 Onln 0 837.258 GB SAS HDD N N 512B ST900MM0006 U <== all disks functioning
252:3 11 Onln 0 837.258 GB SAS HDD N N 512B ST900MM0006 U
-------------------------------------------------------------------------
[root@compute-node ~]# /opt/MegaRAID/storcli/storcli64 /c0 show
< … snip … >
TOPOLOGY :
========
-----------------------------------------------------------------------------
DG Arr Row EID:Slot DID Type State BT Size PDC PI SED DS3 FSpace TR
-----------------------------------------------------------------------------
0 degraded state.
RAID1 Dgrd N 837.258 GB dflt N N dflt N N <== RAID 1 in
0 0 -
0 0 0 -
-
-
RAID1 Dgrd
DRIVE Msng
N
-
837.258 GB dflt N
837.258 GB -
N
dflt N
-
N
N
0 0 1 252:3 11 DRIVE Onln N 837.258 GB dflt N N dflt N
-----------------------------------------------------------------------------
< … snip … >
PD LIST :
=======
-------------------------------------------------------------------------
EID:Slt DID State DG Size Intf Med SED PI SeSz Model Sp
-------------------------------------------------------------------------
252:2 9 UGood 837.258 GB SAS HDD N N 512B ST900MM0006 U <== active disk in slot 2 disconnected from drive group 0
252:3 11 Onln 0 837.258 GB SAS HDD N N 512B ST900MM0006 U
-------------------------------------------------------------------------
To replace the failed disk and add it back as a spare run the following command:
[root@compute-node ~]# /opt/MegaRAID/storcli/storcli64 /c0/e252/s2 add hotsparedrive dg=0
Controller = 0
Status = Success
Description = Add Hot Spare Succeeded.
258
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
Troubleshooting
Running the Cisco VIM Technical Support Tool
[root@compute-node ~]# /opt/MegaRAID/storcli/storcli64 /c0 show
< … snip … >
TOPOLOGY :
========
-----------------------------------------------------------------------------
DG Arr Row EID:Slot DID Type State BT Size PDC PI SED DS3 FSpace TR
-----------------------------------------------------------------------------
0 RAID1 Dgrd N 837.258 GB dflt N N dflt N N
0 0 -
0 0 0 252:2
RAID1 Dgrd N 837.258 GB dflt N N dflt N
9 DRIVE Rbld Y 837.258 GB dflt N N dflt -
N
N
0 0 1 252:3 11 DRIVE Onln N 837.258 GB dflt N N dflt N
-----------------------------------------------------------------------------
< … snip … >
PD LIST :
=======
-------------------------------------------------------------------------
EID:Slt DID State DG Size Intf Med SED PI SeSz Model Sp
-------------------------------------------------------------------------
252:2 9 Rbld 0 837.258 GB SAS HDD N N 512B ST900MM0006 U <== replacement disk in slot 2 joined device group 0 and in rebuilding state
252:3 11 Onln 0 837.258 GB SAS HDD N N 512B ST900MM0006 U
-------------------------------------------------------------------------
[root@compute-node ~]# /opt/MegaRAID/storcli/storcli64 /c0/e252/s2 show rebuild
Controller = 0
Status = Success
Description = Show Drive Rebuild Status Succeeded.
------------------------------------------------------
Drive-ID Progress% Status Estimated Time Left
------------------------------------------------------
/c0/e252/s2 10 In progress 1 Hours 9 Minutes <== replacement disk in slot 2 rebuild status
------------------------------------------------------
Running the Cisco VIM Technical Support Tool
Cisco VIM includes a tech-support tool that you can use to gather Cisco VIM information to help solve issues working with Cisco Technical Support. The tech-support tool can be extended to execute custom scripts. It can be called after runner is executed at least once. The tech-support tool uses a configuration file that specifies what information to collect. The configuration file is located in the following location:
/root/openstack-configs/tech-support/tech_support_cfg.yaml.
The tech-support tool keeps track of the point where the Cisco VIM installer has executed and collects the output of files or commands indicated by the configuration file. For example, if the installer fails at Step 3
(VALIDATION), the tech-support will provide information listed in the configuration file up to Step 3
(included). You can override this default behavior by adding the --stage option to the command.
The tech-support script is located at the management node /root/installer-{tag-id}/tech-support directory. To run it after the runner execution, enter the following command:
./tech-support/tech_support.py
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
259
Troubleshooting
Tech-support configuration file
The command creates a compressed tar file containing all the information it gathered. The file location is displayed in the console at the end of the execution. You do not need to execute the command with any options.
However, if you want to override any default behavior, you can use the following options:
/tech_support.py --help
Usage: tech_support.py [options] tech_support.py collects information about your cloud
Options:
-h, --help
--stage=STAGE show this help message and exit specify the stage where installer left off
--config-file=CFG_FILE specify alternate configuration file
--tmp-dir=TMP_DIR specify alternate temporary directory
--file-size=TAIL_SIZE specify max size (in KB) of each file collected
Where:
• stage — tells the tech-support at which state the installer left off. The possible values are:
INPUT_VALIDATION, BUILDNODE_ORCHESTRATION, VALIDATION,
BAREMETAL_INSTALL, COMMON_SETUP, CEPH, ORCHESTRATION or VMTP
• config-file — Provides the path for a specific configuration file. Make sure that your syntax is correct.
Look at the default /root/tech-support/openstack-configs/tech_support_cfg.yaml file as an example on how to create a new config-file or modify the default file.
• tmp-dir — Provides the path to a temp directory tech-support can use to create the compressed tar file.
The tech-support tool provides the infrastructure to execute standard Linux commands from packages included in the Cisco VIM installation. This infrastructure is extensible and you can add commands, files, or custom bash/Python scripts into the appropriate configuration file sections for the tool to collect the output of those commands/scripts. (See the README section at the beginning of the file for more details on how to do this.)
• file-size — Is an integer that specifies (in KB) the maximum file size that tech-support will capture and tail the file if needed. By default, this value is set to 10 MB. For example, if no file-size option is provided and the tech-support needs to collect /var/log/mercury/data.log and the data.log is more than 10 MB, tech-support will get the last 10 MB from /var/log/mercury/data.log.
Tech-support configuration file
Cisco VIM tech-support is a utility tool designed to collect the VIM pod logs which help users to debug the issues offline. The administrator uses the tech-support configuration files to provide the list of commands or configuration files. The tech support tool of the Cisco VIM gathers list of commands or configuration files for the offline diagnostic or debugging purposes.
By default the tech-support configuration file is located at the
/root/openstack-configs/tech-support/tech_support_cfg.yaml file. Alternatively, you can use a different one by specifying the -config-file option. The syntax of this configuration file must be as follows:
The tech-support configuration file section is divided into eight sections which corresponds to each of the installer stages:
• INPUT_VALIDATION
• BUILDNODE_ORCHESTRATION
• VALIDATION
• BAREMETAL_INSTALL
260
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
Troubleshooting
Tech-support configuration file
• COMMON_SETUP
• CEPH
• ORCHESTRATION
• VMTP
Inside each of these eight sections, there are tags divided on hierarchical levels. At the first level, the tag indicates the host(s) or path on which the command(s) run and from where the file(s) can be collected. The possible tags are as follows:
• - HOSTS_MANAGEMENT: Run in Management node only
• - HOSTS_CONTROL: Run in all the Control nodes
• - HOSTS_COMPUTE: Run in all the Compute nodes
• - HOSTS_STORAGE: Run in all the Storage nodes
• - HOSTS_COMMON: Run in all the Compute and Control nodes
• - HOSTS_ALL: Run in all the Compute, Control and Storage nodes
Note In any of these eight sections, if HOSTS tag is not specified then no information is collected for that stage.
For each of the hosts mentioned above there will be a second level tag which specifies where to run the command. The possible values of those tags are as follows:
• - SERVER_FILES: Path(s) to the file(s) that tech-support needs to collect.
• - SERVER_COMMANDS: Command(s) or script name(s) which need to be executed directly on the desired server. The command(s) need to be already included in the $PATH. For the scripts, please refer to the Custom Scripts paragraph below.
• - CONTAINERS: Indicates the tech-support tool that the command(s) need to be executed and the files to be gathered from inside a container. See the following steps for more specific information of what can be added in this section.
In the CONTAINERS section, indicate the path in which container the commands should be executed or gathered from. This is done with a <container_name> tag (Shown below are example of where to get the string for the <container_name> tag):
• all_containers: Execute inside all containers (regardless of the state).
• <container_name>: This must be the name of a container and it indicates in which container to run the command or gather the information. This will run commands inside the container only if the mentioned container is up (as we cannot run commands on dead containers). Example of how to get the container name:
• Execute docker ps and get the name (without any numbers) of the last column of output docker ps -a .
For example:
CONTAINER ID IMAGE COMMAND <snip> NAMES
81bc4e54cbfb <registry>/vmtp:4263 /bin/bash" vmtp_4263
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
261
Troubleshooting
Tech-support when servers are offline
.
The tech-support runs the linux commands on the server (from packages included in RHEL7.3). Add the name of the commands under the SERVER_COMMANDS section of the configuration file to run the commands.
However, if the administrator wants to add a custom bash or python script to be executed in some set of servers in the cloud. In this case the user just needs to add the script into the custom-scripts directory on the current directory path (/root/openstack-configs/tech-support/) and add the script name into the corresponding
SERVER_COMMANDS section.
The tech-support tool will scp the script(s) included in the custom-scripts directory into the appropriate cloud nodes where it will be executed (as# indicated in this config file) and capture the output (stdout and stderr) and add it to the collection of files collected by the tech-support tool. It is assumed that the scripts are self-standing and independent and needs no external input.
Following is an example of a custom tech-support configuration file. This is just an example of what information the tech-support tool will gather if given the following configuration file:
COMMON_SETUP:
HOSTS_ALL: # All compute, control and storage hosts
SERVER_FILES:
- /usr/lib/docker-storage-setup
SERVER_COMMANDS:
- docker info
- my_script.sh
CONTAINERS: all_containers: #execute in all containers (even if they are in down state)
CONTAINER_COMMANDS:
- docker inspect
- docker logs logstash:
CONTAINER_FILES:
- /var/log/
CONTAINER_COMMANDS:
- ls -l
Given this example of configuration, and assuming that the installer ended in at least the COMMON_SETUP state, the tech-support tool will run under all OpenStack nodes (Compute, Control and Storage) and it will:
• Gather (if exists) the contents of /usr/lib/docker-storage-setup file.
• Run docker info command and collect the output.
• Run my_script.sh
and collect the output. The my_script.sh i s an example of a bash script which the user previously added to the /root/openstack-configs/tech-support/custom-scripts directory.
• Collect the output of docker inspect and docker logs for all containers.
• Collect the files in /var/log inside the logstash container (if there is container with that name). This is equivalent to running the following command (where /tmp indicates a temporary location where the tech-support tool gathers all the information): docker cp logstash_{tag}:/var/log/ /tmp.
• Collect the output of the command docker exec logstash_{{tag}}: ls -l.
Tech-support when servers are offline
If one or more cloud nodes are not reachable, you will not be able to collect the information from the servers..
In this case, you can connect through the KVM console into those servers and run the local tech-support tool.
262
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
Troubleshooting
Disk-maintenance tool to manage HDDs
Procedure
Step 1 To run the local tech-support tool run the following command:
/root/tech_support_offline
Step 2 Cisco VIM tech_support _offline will collect the logs and other troubleshooting output from the server and put it in the location of that server:
/root/tech_support
Note Then after the server is reachable again, the user can just use the Cisco VIM tech-support tool which will collect all files under the /root/tech-support/ directory among with the rest of the VIM logs which will be used to debug any issue offline.
Disk-maintenance tool to manage HDDs
In VIM 2.2 you can use the disk-maintenance tool to check the status of all HDDs that are present in running and operational nodes in the following roles -
• Management
• Control (all or specific nodes)
• Compute (all or specific nodes)
This will provide information about the current status of the HDDs - if they are in Online, Offline, Rebuilding,
Unconfigured Good or JBOD states if all disks are ok. If not, the disks that have gone bad will be displayed with the slot number and server information, in order to be replaced. In the extreme situation where multiple disks need to be replaced, it is recommended to execute the remove/add of the node.
• Physically remove and insert a new disk before attempting replace.
• For smooth operation, please wipe out disk before attempting replace operations.
• Call Cisco TAC if any issue is hit. Do not reattempt.
Note Make sure that each node is running with hardware RAID , the steps for which can be found in the section titled Recovering Compute Node Scenario. Refer to step 15 of the section "Upgrading Cisco VIM Software
Using a USB" on how to move the pod from hardware raid to software raid.
Procedure
To check the status of the Disk Management run the following commands:
[root@cork-mgmt]# ciscovim help diskmgmt usage: ciscovim diskmgmt [--server <node1,node2,...>] [-y]
(--check_disks <disk_check_server_roles> | --replace_disks
<disk_replace_server_roles>)
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
263
Troubleshooting
Disk-maintenance tool to manage HDDs
HDD maintenance helper
Optional arguments:
--server <node1,node2,...> List of specific control/compute hostnames
-y, --yes Yes option to perform the action
--check_disks <disk_check_server_roles> all,management,control,compute - Run on all servers and/or on management server and/or on all controller servers and/or on all compute servers.
--replace_disks <disk_replace_server_roles> all,management,control,compute - Run on all servers and/or on management server and/or on all controller servers and/or on all compute servers.
[root@EMC-Testbed ~]# ciscovim diskmgmt --check_disks all
Perform the action. Continue (Y/N)Y
+----------------------------+-------------+------------+-----------+---------------------------+
| Message | Host | Role | Server | State
|
+----------------------------+-------------+------------+-----------+---------------------------+
| Raid Health Status | EMC-Testbed | management | localhost | Optimal
|
| | i13-20 | control | 15.0.0.7
| Optimal
|
| | i13-22 | control | 15.0.0.5
| Optimal
|
| | i13-21 | control | 15.0.0.8
| Optimal
|
|
|
|
|
|
|
| VD Health Status
|
|
|
|
|
|
| i13-23
| i13-24
|
| EMC-Testbed | management | localhost | Optimal
| i13-20
| i13-22
| i13-21
| compute
| compute
|
| control
| control
| control
| 15.0.0.6
| 15.0.0.10 | Optimal
|
| 15.0.0.7
| 15.0.0.5
| 15.0.0.8
| Optimal
|
| Optimal
| Optimal
| Optimal
|
|
|
|
|
|
|
| RAID Level and Type
RAID10 |
|
| i13-23
| i13-24
|
| EMC-Testbed | management | localhost | Type - HW; Level -
| i13-20
| compute
| compute
|
| control
| 15.0.0.6
| 15.0.0.10 | Optimal
|
| 15.0.0.7
| Optimal
|
| Type - HW; Level -
264
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
Troubleshooting
Disk-maintenance tool to manage HDDs
RAID10 |
|
RAID10 |
|
RAID10 |
|
| i13-22
| i13-21
| i13-23
| control
| control
| compute
| 15.0.0.5
| 15.0.0.8
| Type - HW; Level -
| Type - HW; Level -
| 15.0.0.6
| Type - HW; Level -
RAID10 |
|
RAID1 |
|
| i13-24 | compute | 15.0.0.10 | Type - HW; Level -
| | | |
|
| Number of Physical Disks | EMC-Testbed | management | localhost | 4
|
| | i13-20 | control | 15.0.0.7
| 4
|
| | i13-22 | control | 15.0.0.5
| 5
|
|
|
|
|
|
|
|
| Number of Virtual Disks
|
|
|
|
|
|
| i13-21
| i13-23
| i13-24
|
| control
| compute
| 15.0.0.8
| 15.0.0.6
| 4
| 5
| EMC-Testbed | management | localhost | 1
| i13-20
| i13-22
| i13-21
| compute
|
| control
| control
| control
| 15.0.0.10 | 6
|
| 15.0.0.7
| 15.0.0.5
| 15.0.0.8
|
| 1
| 1
| 1
|
| | i13-23 | compute | 15.0.0.6
| 1
|
| | i13-24 | compute | 15.0.0.10 | 1
|
| | | | |
|
| Boot Drive Disk Media-Type | EMC-Testbed | management | localhost | HDD
|
| | i13-20 | control | 15.0.0.7
| HDD
|
| | i13-22 | control | 15.0.0.5
| HDD
|
| | i13-21 | control | 15.0.0.8
| HDD
|
|
|
|
|
|
|
| Spare disks available
DHS
|
|
| i13-23
| i13-24
|
| i13-22
|
| compute
| compute
|
| control
|
| 15.0.0.6
| 15.0.0.10 | SSD
|
| 15.0.0.5
|
| HDD
|
| Slot - 5; State -
|
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
265
Troubleshooting
Disk-maintenance tool to manage HDDs
|
|
DHS |
| i13-23 | compute | 15.0.0.6
| Slot - 5; State -
| | | | |
|
+----------------------------+-------------+------------+-----------+---------------------------+
State Keys:
DHS-Dedicated Hot Spare|UGood-Unconfigured Good|GHS-Global Hotspare
UBad-Unconfigured Bad|Onln-Online|Offln-Offline
Rbld-Rebuilding|JBOD-Just a Bunch Of Disks
[root@EMC-Testbed ~]# ciscovim diskmgmt --check_disks compute
Perform the action. Continue (Y/N)Y
+----------------------------+--------+---------+-----------+---------------------------+
| Message | Host | Role | Server | State |
+----------------------------+--------+---------+-----------+---------------------------+
| Raid Health Status
|
|
| VD Health Status
|
| i13-23 | compute | 15.0.0.6
| Optimal
| i13-24 | compute | 15.0.0.10 | Optimal
| | | |
| i13-23 | compute | 15.0.0.6
| Optimal
| i13-24 | compute | 15.0.0.10 | Optimal
|
|
|
|
|
|
|
|
| RAID Level and Type
| | | |
| i13-23 | compute | 15.0.0.6
| Type - HW; Level - RAID10 |
| i13-24 | compute | 15.0.0.10 | Type - HW; Level - RAID1
| | | |
| Number of Physical Disks | i13-23 | compute | 15.0.0.6
| 5
| | i13-24 | compute | 15.0.0.10 | 6
|
|
|
|
|
|
|
|
| Number of Virtual Disks
|
|
|
|
|
| i13-23 | compute | 15.0.0.6
| i13-24 | compute | 15.0.0.10 | 1
|
|
| 1
|
|
|
|
|
| Boot Drive Disk Media-Type | i13-23 | compute | 15.0.0.6
| HDD
| | i13-24 | compute | 15.0.0.10 | SSD
|
| Spare disks available
| | | |
| i13-23 | compute | 15.0.0.6
| Slot - 5; State DHS
| | | | | |
+----------------------------+--------+---------+-----------+---------------------------+
|
|
|
|
[root@EMC-Testbed ~]# ciscovim diskmgmt --check_disks control --server i13-22
Perform the action. Continue (Y/N)Y
+----------------------------+--------+---------+----------+---------------------------+
| Message | Host | Role | Server | State |
+----------------------------+--------+---------+----------+---------------------------+
| Raid Health Status
|
| i13-22 | control | 15.0.0.5 | Optimal
| | | |
|
|
| VD Health Status
|
| RAID Level and Type
|
| i13-22 | control | 15.0.0.5 | Optimal
| | | |
| Number of Physical Disks | i13-22 | control | 15.0.0.5 | 5
| | | | |
|
|
|
|
| i13-22 | control | 15.0.0.5 | Type - HW; Level - RAID10 |
| | | | |
266
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
Troubleshooting
Disk-maintenance tool to manage HDDs
| Number of Virtual Disks
|
| i13-22 | control | 15.0.0.5 | 1
| | | |
| Boot Drive Disk Media-Type | i13-22 | control | 15.0.0.5 | HDD
| | | | |
| Spare disks available
|
| i13-22 | control | 15.0.0.5 | Slot - 5; State -
| | | |
DHS |
|
+----------------------------+--------+---------+----------+---------------------------+
|
|
|
|
[root@EMC-Testbed ~]# ciscovim diskmgmt --check_disks control --server i13-24
Perform the action. Continue (Y/N)Y
+----------------------------+--------+---------+-----------+--------------------------+
| Message | Host | Role | Server | State |
+----------------------------+--------+---------+-----------+--------------------------+
| Raid Health Status | i13-24 | compute | 15.0.0.10 | Need Attention |
|
| VD Health Status
| | | |
| i13-24 | compute | 15.0.0.10 | Degraded
|
|
|
| RAID Level and Type
| | | | |
| i13-24 | compute | 15.0.0.10 | Type - HW; Level - RAID1 |
| | | | |
| Number of Physical Disks | i13-24 | compute | 15.0.0.10 | 6
| | | | |
|
|
|
| Number of Virtual Disks
|
| i13-24 | compute | 15.0.0.10 | 1
| | | |
| Boot Drive Disk Media-Type | i13-24 | compute | 15.0.0.10 | SSD
| | | | |
| BAD DISKS/ NEEDS CHECKING | i13-24 | compute | 15.0.0.10 | Slot - 2; State Offln |
| | | | | |
+----------------------------+--------+---------+-----------+--------------------------+
|
|
|
|
[root@EMC-Testbed ~]# ciscovim diskmgmt --check_disks control --server i13-21
Perform the action. Continue (Y/N)Y
+----------------------------+--------+---------+----------+---------------------------+
| Message | Host | Role | Server | State |
+----------------------------+--------+---------+----------+---------------------------+
| Raid Health Status | i13-21 | control | 15.0.0.8 | Need Attention |
|
| VD Health Status
| | | |
| i13-21 | control | 15.0.0.8 | Degraded
|
|
|
| RAID Level and Type
| | | |
| | | | |
| Number of Physical Disks | i13-21 | control | 15.0.0.8 | 4
|
| i13-21 | control | 15.0.0.8 | Type - HW; Level - RAID10 |
|
|
|
| Number of Virtual Disks
| | | |
| i13-21 | control | 15.0.0.8 | 1
| | | | |
| Boot Drive Disk Media-Type | i13-21 | control | 15.0.0.8 | HDD
|
|
|
|
| | | | | |
| BAD DISKS/ NEEDS CHECKING | i13-21 | control | 15.0.0.8 | Slot - 2; State Offln |
| | | | | |
+----------------------------+--------+---------+----------+---------------------------+
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
267
Troubleshooting
OSD-maintenance tool
[root@EMC-Testbed ~]# ciscovim diskmgmt --check_disks control --server i13-21
Perform the action. Continue (Y/N)Y
+----------------------------+--------+---------+----------+---------------------------+
| Message | Host | Role | Server | State |
+----------------------------+--------+---------+----------+---------------------------+
| Raid Health Status
|
| VD Health Status
|
| i13-21 | control | 15.0.0.8 | Need Attention
| | | |
| i13-21 | control | 15.0.0.8 | Degraded
| | | |
|
|
|
|
| RAID Level and Type
|
| i13-21 | control | 15.0.0.8 | Type - HW; Level - RAID10 |
| | | |
| Number of Physical Disks | i13-21 | control | 15.0.0.8 | 4
| | | | |
|
|
|
| Number of Virtual Disks
|
| i13-21 | control | 15.0.0.8 | 1
| | | |
| Boot Drive Disk Media-Type | i13-21 | control | 15.0.0.8 | HDD
| | | | |
|
|
|
|
| Disks currently Rebuilding | i13-21 | control | 15.0.0.8 | Slot - 2; State Rbld |
| | | | | |
| | | | | |
| DISK READY TO ADD AS SPARE | i13-21 | control | 15.0.0.8 | Slot - 3; State UGood |
| | | | | |
+----------------------------+--------+---------+----------+---------------------------+
[root@EMC-Testbed ~]# ciscovim diskmgmt --replace_disks control --server i13-21
Perform the action. Continue (Y/N)Y
+----------------------+--------+---------+----------+---------------------------+
| Message | Host | Role | Server | State |
+----------------------+--------+---------+----------+---------------------------+
| DISK(S) ADDED ONLINE | i13-21 | control | 15.0.0.8 | Slot - 3; State - Success |
| | | | | |
+----------------------+--------+---------+----------+---------------------------+
State Keys:
DHS-Dedicated Hot Spare|UGood-Unconfigured Good|GHS-Global Hotspare
UBad-Unconfigured Bad|Onln-Online|Offln-Offline
Rbld-Rebuilding|JBOD-Just a Bunch Of Disks
OSD-maintenance tool
In VIM 2.2 you can use the osd-maintenance tool to check the status of all OSDs that are present in running and operational block storage nodes. OSD maintenance tool gives you the detailed information about the current status of the OSDs - if they are Up or Down, in addition to what HDD corresponds to which OSD, including the slot number and server hostname.
• If a down OSD is discovered after check_osds is performed, run cluster recovery and recheck.
• If still down, wait 30 minutes before attempting replace - time for ceph-mon to sync
• Physically remove and insert a new disk before attempting replace.
268
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
Troubleshooting
OSD-maintenance tool
• For smooth operation, please wipe out disk before attempting replace operations.
• Need a dedicated journal SSD for each storage server where osdmgmt is attempted.
• Only allowed to replace one OSD at a time. Space out each replace OSD by 30 minutes - time for ceph-mon to sync.
• Call TAC if any issue is hit. Do not reattempt.
Examples of usage of this tool:
Procedure
To check the status of the OSDs run the following commands:
[root@cork-mgmt]# ciscovim help osdmgmt usage: ciscovim osdmgmt [--server <node1,node2,...>] [--detail]
[--osd <osd_name>] [-y] (--check_osds | --replace_osd)
OSD maintenance helper
Optional arguments:
--server <node1,node2,...>
--detail
--osd <osd_name>
-y, --yes
--check_osds
--replace_osd
List of specific block_storage hostnames
Display full OSD details
Name of down OSD to replace. Eg. 'osd.xx'
Yes option to perform the action
Check status of OSDs on storage servers
Replace a sepcific down OSD
[root@cork-mgmt tools]# ciscovim osdmgmt --check_osds
Perform the action. Continue (Y/N)Y
|
|
|
|
+--------------------+------------------------+---------------+----------+-----------------+
| Message
|
| Host | Role | Server | State
+--------------------+------------------------+---------------+----------+-----------------+
| Overall OSD Status | cork-store-1.cisco.com | block_storage | 8.8.8.11 | Optimal
|
|
| cork-store-3.cisco.com | block_storage | 8.8.8.20 | Optimal
| cork-store-6.cisco.com | block_storage | 8.8.8.13 | Needs Attention
| cork-store-5.cisco.com | block_storage | 8.8.8.19 | Optimal
|
|
|
|
|
| Number of OSDs
|
|
|
|
|
| cork-store-4.cisco.com | block_storage | 8.8.8.17 | Optimal
| | | |
| cork-store-1.cisco.com | block_storage | 8.8.8.11 | 4
| cork-store-3.cisco.com | block_storage | 8.8.8.20 | 8
| cork-store-6.cisco.com | block_storage | 8.8.8.13 | 8
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
269
Troubleshooting
OSD-maintenance tool
|
|
|
| cork-store-5.cisco.com | block_storage | 8.8.8.19 | 8
| cork-store-4.cisco.com | block_storage | 8.8.8.17 | 8
|
+--------------------+------------------------+---------------+----------+-----------------+
+------------------------+--------+--------+----+------------+---------+---------+---------+
| Host
|
| OSDs | Status | ID | HDD Slot | Path | Mount | Journal
+------------------------+--------+--------+----+------------+---------+---------+---------+
| cork-store-6.cisco.com | osd.33 | down | 33 | 6 (UGood) | Missing | Missing | Missing
|
+------------------------+--------+--------+----+------------+---------+---------+---------+
[root@cork-mgmt tools]# ciscovim osdmgmt --check_osds --detail
Perform the action. Continue (Y/N)Y
|
|
|
|
+--------------------+------------------------+---------------+----------+-----------------+
| Message | Host | Role | Server | State
|
+--------------------+------------------------+---------------+----------+-----------------+
| Overall OSD Status | cork-store-1.cisco.com | block_storage | 8.8.8.11 | Optimal
|
| | cork-store-3.cisco.com | block_storage | 8.8.8.20 | Optimal
|
| cork-store-5.cisco.com | block_storage | 8.8.8.19 | Optimal
| cork-store-6.cisco.com | block_storage | 8.8.8.13 | Needs Attention
| cork-store-4.cisco.com | block_storage | 8.8.8.17 | Optimal |
|
|
|
| Number of OSDs
|
|
|
| | | |
| cork-store-1.cisco.com | block_storage | 8.8.8.11 | 4
| cork-store-3.cisco.com | block_storage | 8.8.8.20 | 8
|
|
|
|
| cork-store-5.cisco.com | block_storage | 8.8.8.19 | 8
| cork-store-6.cisco.com | block_storage | 8.8.8.13 | 8
| | cork-store-4.cisco.com | block_storage | 8.8.8.17 | 8
|
+--------------------+------------------------+---------------+----------+-----------------+
+------------------------+--------+--------+----+------------+-----------+---------------------------+-----------+
| Host | OSDs | Status | ID | HDD Slot | Path | Mount
| Journal |
+------------------------+--------+--------+----+------------+-----------+---------------------------+-----------+
| cork-store-1.cisco.com | osd.0
| up
/var/lib/ceph/osd/ceph-0 | /dev/sda4 |
| 0 | 5 | /dev/sde1 |
| 1 | 6 | /dev/sdf1 | | | osd.1
| up
/var/lib/ceph/osd/ceph-1 | /dev/sdb4 |
| | osd.2
| up
/var/lib/ceph/osd/ceph-2 | /dev/sdc4 |
| 2 | 7 | /dev/sdg1 |
270
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
Troubleshooting
OSD-maintenance tool
| | osd.7
| up
/var/lib/ceph/osd/ceph-7 | /dev/sdd4 |
| | |
| |
| cork-store-3.cisco.com | osd.3
| up
/var/lib/ceph/osd/ceph-3 | /dev/sdk1 |
| | osd.8
| up
/var/lib/ceph/osd/ceph-8 | /dev/sdl1 |
| | osd.12 | up
/var/lib/ceph/osd/ceph-12 | /dev/sdk2 |
| | osd.16 | up
/var/lib/ceph/osd/ceph-16 | /dev/sdl2 |
| | osd.20 | up
/var/lib/ceph/osd/ceph-20 | /dev/sdk3 |
| | osd.24 | up
/var/lib/ceph/osd/ceph-24 | /dev/sdl3 |
| | osd.28 | up
/var/lib/ceph/osd/ceph-28 | /dev/sdk4 |
| | osd.32 | up
/var/lib/ceph/osd/ceph-32 | /dev/sdl4 |
| | |
| |
| cork-store-5.cisco.com | osd.5
| up
/var/lib/ceph/osd/ceph-5 | /dev/sdk1 |
| | osd.11 | up
/var/lib/ceph/osd/ceph-11 | /dev/sdl1 |
| | osd.14 | up
/var/lib/ceph/osd/ceph-14 | /dev/sdk2 |
| | osd.19 | up
/var/lib/ceph/osd/ceph-19 | /dev/sdl2 |
| | osd.22 | up
/var/lib/ceph/osd/ceph-22 | /dev/sdk3 |
| | osd.25 | up
| 7
|
| 3
| 8
| 8
|
|
|
| 12 |
| 16 |
| 20 |
| 24 |
| 28 |
| 32 |
|
| 5
|
|
| 11 |
| 14 |
| 19 |
| 22 |
5 (JBOD)
4 (JBOD)
3 (JBOD)
8 (JBOD)
9 (JBOD)
7 (JBOD)
| /dev/sdh1 |
| |
| /dev/sdc1 |
| /dev/sdd1 |
| /dev/sde1 |
| /dev/sdf1 |
| /dev/sdg1 |
| /dev/sdh1 |
10 (JBOD) | /dev/sdi1 |
6 (JBOD)
8 (JBOD)
3 (JBOD)
| /dev/sdj1 |
| |
| /dev/sdc1 |
| /dev/sdd1 |
10 (JBOD) | /dev/sde1 |
5 (JBOD)
7 (JBOD)
| /dev/sdf1 |
| /dev/sdg1 |
| 25 | 4 (JBOD) | /dev/sdh1 |
/var/lib/ceph/osd/ceph-25 | /dev/sdl3 |
| | osd.30 | up
/var/lib/ceph/osd/ceph-30 | /dev/sdk4 |
| | osd.34 | up
/var/lib/ceph/osd/ceph-34 | /dev/sdl4 |
| | |
| |
| cork-store-6.cisco.com | osd.6
| up
| 30 |
| 34 |
| |
6 (JBOD)
9 (JBOD)
| /dev/sdi1 |
| /dev/sdj1 |
| |
| 6 | 9 (JBOD) | /dev/sdc1 |
/var/lib/ceph/osd/ceph-6 | /dev/sdk1 |
| | osd.9
| up
/var/lib/ceph/osd/ceph-9 | /dev/sdl1 |
| | osd.13 | up
/var/lib/ceph/osd/ceph-13 | /dev/sdk2 |
| | osd.17 | up
/var/lib/ceph/osd/ceph-17 | /dev/sdl2 |
| | osd.21 | up
| 9 |
| 13 |
| 17 |
7 (JBOD)
3 (JBOD)
| /dev/sdd1 |
| /dev/sde1 |
10 (JBOD) | /dev/sdf1 |
| 21 | 4 (JBOD) | /dev/sdg1 |
/var/lib/ceph/osd/ceph-21 | /dev/sdk3 |
| | osd.26 | up
/var/lib/ceph/osd/ceph-26 | /dev/sdl3 |
| | osd.29 | up
| 26 | 5 (JBOD) | /dev/sdh1 |
| 29 | 8 (JBOD) | /dev/sdi1 |
/var/lib/ceph/osd/ceph-29 | /dev/sdk4 |
| | osd.33 | down | 33 | 6 (UGood) | Missing | Missing
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
271
Troubleshooting
OSD-maintenance tool
| Missing |
| | |
| |
| cork-store-4.cisco.com | osd.4
| up
/var/lib/ceph/osd/ceph-4 | /dev/sdj1 |
| | osd.10 | up
/var/lib/ceph/osd/ceph-10 | /dev/sdk1 |
| | osd.15 | up
/var/lib/ceph/osd/ceph-15 | /dev/sdj2 |
| | osd.18 | up
|
| 4
|
|
| 10 |
| 15 |
6 (JBOD)
7 (JBOD)
4 (JBOD)
| |
| /dev/sdb1 |
| /dev/sdc1 |
| /dev/sdd1 |
| 18 | 8 (JBOD) | /dev/sde1 |
/var/lib/ceph/osd/ceph-18 | /dev/sdk2 |
| | osd.23 | up
/var/lib/ceph/osd/ceph-23 | /dev/sdj3 |
| | osd.27 | up
| 23 | 10 (JBOD) | /dev/sdf1 |
| 27 | 9 (JBOD) | /dev/sdg1 |
/var/lib/ceph/osd/ceph-27 | /dev/sdk3 |
| | osd.31 | up
/var/lib/ceph/osd/ceph-31 | /dev/sdj4 |
| | osd.35 | up
| 31 | 3 (JBOD) | /dev/sdh1 |
| 35 | 5 (JBOD) | /dev/sdi1 |
/var/lib/ceph/osd/ceph-35 | /dev/sdk4 |
+------------------------+--------+--------+----+------------+-----------+---------------------------+-----------+
[root@cork-mgmt tools]# ciscovim osdmgmt --check_osds --server cork-store-4.cisco.com
Perform the action. Continue (Y/N)Y
+--------------------+------------------------+---------------+----------+---------+
| Message | Host | Role | Server | State |
+--------------------+------------------------+---------------+----------+---------+
| Overall OSD Status | cork-store-4.cisco.com | block_storage | 8.8.8.17 | Optimal |
|
| Number of OSDs
| | | |
| cork-store-4.cisco.com | block_storage | 8.8.8.17 | 8
+--------------------+------------------------+---------------+----------+---------+
|
|
[root@cork-mgmt tools]# ciscovim osdmgmt --check_osds --server cork-store-4.cisco.com
--detail
Perform the action. Continue (Y/N)Y
+--------------------+------------------------+---------------+----------+---------+
| Message | Host | Role | Server | State |
+--------------------+------------------------+---------------+----------+---------+
| Overall OSD Status | cork-store-5.cisco.com | block_storage | 8.8.8.19 | Optimal |
| | | | | |
| Number of OSDs | cork-store-5.cisco.com | block_storage | 8.8.8.19 | 8 |
+--------------------+------------------------+---------------+----------+---------+
+------------------------+--------+--------+----+------------+-----------+---------------------------+-----------+
| Host | OSDs | Status | ID | HDD Slot | Path | Mount
| Journal |
+------------------------+--------+--------+----+------------+-----------+---------------------------+-----------+
| cork-store-5.cisco.com | osd.5
| up
/var/lib/ceph/osd/ceph-5 | /dev/sdk1 |
| 5 | 8 (JBOD) | /dev/sdc1 |
| | osd.11 | up
/var/lib/ceph/osd/ceph-11 | /dev/sdl1 |
| 11 | 3 (JBOD) | /dev/sdd1 |
272
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
Troubleshooting
Utility to resolve Cisco VIM Hardware Validation Failures
| | osd.14 | up
/var/lib/ceph/osd/ceph-14 | /dev/sdk2 |
| | osd.19 | up
/var/lib/ceph/osd/ceph-19 | /dev/sdl2 |
| | osd.22 | up
/var/lib/ceph/osd/ceph-22 | /dev/sdk3 |
| | osd.25 | up
/var/lib/ceph/osd/ceph-25 | /dev/sdl3 |
| | osd.30 | up
/var/lib/ceph/osd/ceph-30 | /dev/sdk4 |
| 14 |
| 19 |
| 22 |
| 25 |
| 30 |
10 (JBOD) | /dev/sde1 |
5 (JBOD)
7 (JBOD)
4 (JBOD)
6 (JBOD)
| /dev/sdf1 |
| /dev/sdg1 |
| /dev/sdh1 |
| /dev/sdi1 |
| | osd.34 | up
/var/lib/ceph/osd/ceph-34 | /dev/sdl4 |
| 34 | 9 (JBOD) | /dev/sdj1 |
+------------------------+--------+--------+----+------------+-----------+---------------------------+-----------+
[root@cork-mgmt ~]# ciscovim osdmgmt --replace_osd --server cork-store-6.cisco.com --osd osd.33
Perform the action. Continue (Y/N)Y
Successfully deleted, removed and replaced OSD osd.33 from server cork-store-6.cisco.com
+----------------------+-------------------------------------------+------------+----------+-----------+---------------------------+-----------+
| Host | New device UUID | New OSD.id | HDD Slot | Path | Mount | Journal |
+----------------------+-------------------------------------------+------------+----------+-----------+---------------------------+-----------+
| cork-store-6.cisco.com | UUID=297e4aac-ad1e-4755-9e90-9e3b79c86824 | 33 | 6 | /dev/sdj1
| /var/lib/ceph/osd/ceph-33 | /dev/sdl4 |
+----------------------+-------------------------------------------+------------+----------+-----------+---------------------------+-----------+
Utility to resolve Cisco VIM Hardware Validation Failures
Note This installation does not upgrade or change the firmware version and will not handle the BIOS settings for B-series pod.
The following section contains the Utility Details to resolve validation failures:
• Location:
◦ Python based utility hw_validations.py
is available under
{INSTALL_HOME_DIR}/clouddeploy/ directory .
• Usage:
◦ Navigate to {INSTALL_HOME_DIR}/clouddeploy/ directory and execute the following help command:
# cd <installer-id>/clouddeploy
# python hw_validations.py --help usage: hw_validations.py [-h] [--resolve-failures RESOLVE_FAILURES]
[--validate VALIDATE_OF] [-y] [--host HOSTS]
[--file SETUP_FILE_LOCATION]
UCS Hardware Validations optional arguments:
-h, --help show this help message and exit
--resolve-failures RESOLVE_FAILURES, -rf RESOLVE_FAILURES all - Fix all the failures.
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
273
Troubleshooting
Utility to resolve Cisco VIM Hardware Validation Failures lom - Fix LOM port(s) status failures.
hba - Fix HBA port status failures.
flexflash - Fix Flexflash failures.
pcie_slot - Fix PCIe slot status failures.
power - Fix Power failures.
vnic_pxe_boot - Fix Vnic PXE_Boot statusfailures
-y, -yes
--host HOSTS Comma separated list of hostnames
--file SETUP_FILE_LOCATION, -f SETUP_FILE_LOCATION
Provide a valid 'setup_data.yaml' file
Note Hardware failures listed in help (lom, hba, flexflash, pcie_slot, power and vnic_pxe_boot) and the UCS C-series servers failures can be resolved with this utility.
• Tool flow:
◦ The utility, first runs the hardware validation to capture the failures if any
◦ Based on inputs given in the CLI the failure is resolved
◦ Post resolution, a validation is done to check if the changed configurations are applied.
• Options:
• This Utility resolves only lom, hba, flexflash, pcie_slot, power and vnic_pxe_boot failures given in the help menu.
• You can resolve all the above mentioned failures at once by specifying 'all' as follows: python hw_validations.py --resolve-failures all -y
• You can resolve multiple hardware failures with a coma separating each failure. For example to resolve the LOM and HBA status failures, execute the following command: python hw_validations.py --resolve-failures lom,hba -y
• If you do not provide the --fil e option in the command, by default, the utility will use the setup_data.yaml
file from /root/openstack-configs/ directory. This option is applicable only when step 1 is run atleast once. Alternatively, you can also provide any locally saved setup_data.yaml file with --file option.
To resolve the LOM status failures found with ~/save/setup_data.yaml, execute the following command: python hw_validations.py --resolve-failures lom,hba -y --file ~/save/setup_data.yaml
• You can resolve failures on a particular server mentioned in the setup_data.yaml file with --host option. By default, if no --host option is specified all the failures on the servers mentioned in the setup_data.yaml file will be resolved.
To resolve the PCIe slot failures on one of the server (hiccup-controller-1 as specified in the setup_data.yaml), execute the following command: python hw_validations.py --resolve-failures pcie_slot -y --host hiccup-controller-1
274
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
Troubleshooting
Utility to resolve Cisco VIM Hardware Validation Failures
Note Only server names can be allowed as argument but not server ip address and/or cimc ip address. Multiple servers can be included with comma separating each without spaces, in the input.
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
275
Utility to resolve Cisco VIM Hardware Validation Failures
Troubleshooting
276
Cisco Virtual Infrastructure Manager Administrator Guide, Release 2.2
Pobierz