Cisco Headend System Release 9.0 Installation and Configuration Guide
Advertisement
Advertisement
PowerKEY CAS Gateway 4.1
Installation and Configuration Guide
Please Read
Important
Read this entire guide. If this guide provides installation or operation instructions, give particular attention to all safety statements included in this guide.
Notices
Trademark Acknowledgments
Cisco and the Cisco logo are trademarks or registered trademarks of Cisco and/or its affiliates in the U.S. and other countries. To view a list of Cisco trademarks, go to this
URL: www.cisco.com/go/trademarks .
Third party trademarks mentioned are the property of their respective owners.
The use of the word partner does not imply a partnership relationship between
Cisco and any other company. (1110R)
Publication Disclaimer
Cisco Systems, Inc. assumes no responsibility for errors or omissions that may appear in this publication. We reserve the right to change this publication at any time without notice. This document is not to be construed as conferring by implication, estoppel, or otherwise any license or right under any copyright or patent, whether or not the use of any information in this document employs an invention claimed in any existing or later issued patent.
Copyright
© 2018-2019 Cisco and/or its affiliates. All rights reserved.
Information in this publication is subject to change without notice. No part of this publication may be reproduced or transmitted in any form, by photocopy, microfilm, xerography, or any other means, or incorporated into any information retrieval system, electronic or mechanical, for any purpose, without the express permission of Cisco Systems, Inc.
Contents
About This Guide v
Chapter 1 System Requirements 1
Hardware Requirements ......................................................................................................... 2
Software Requirements ........................................................................................................... 3
Chapter 2 Install the Software on the EC/DTACS Server 5
Installing the PCG Package on the EC or DTACS Server .................................................. 6
Chapter 3 Deploy the PCG Virtual Machine 7
Deploying the PCG Virtual Machine from the vSphere Web UI ...................................... 8
Reconfiguring the PCG Virtual Hardware ........................................................................... 9
Power On and Login to the New PCG Virtual Machine .................................................. 10
Configuring the PCG Network ............................................................................................ 11
Updating the Time Zone ....................................................................................................... 14
Installing VMware Tools (Optional) ................................................................................... 16
Chapter 4 Provision the PCG on the EC/DTACS Web UI 17
Provisioning the PCG on the EC Web UI ........................................................................... 18
Provisioning the PCG on the DTACS Web UI ................................................................... 22
Chapter 5 Verify PCG Versions 27
Verifying PCG Package Versions on the EC/DTACS ...................................................... 28
Verifying the PCG Version on the PCG Server ................................................................. 29
Chapter 6 Configure SNMPv2 31
Configuring SNMPv2 ............................................................................................................ 32
Configuring SNMPv3 ............................................................................................................ 33 iii
Contents
Appendix A Hardware Configuration Procedures for the Cisco
UCS C220 Server 35
Cisco UCS C220 Server Diagram ......................................................................................... 36
Cisco UCS C220 Server CIMC Configuration .................................................................... 38
RAID Configuration .............................................................................................................. 40
Appendix B Backup and Restore Keyfiles 45
Backing Up Keyfiles .............................................................................................................. 46
Restoring Keyfiles to a Recovered System ......................................................................... 47
Appendix C Upgrade the PCG Server 49
Upgrading the PCG Package on the EC/DTACS System ................................................ 50
Upgrading the PCG Package on the PCG Server .............................................................. 51
Appendix D Manually Configure the PCG Network 53
Manually Configuring the PCG Network .......................................................................... 54
Appendix E Deliver ECMs to DHCTs 57
Delivering ECMs .................................................................................................................... 58
Appendix F Troubleshoot PCG Issues 61
Troubleshooting Boot Issues ................................................................................................ 62
Removing the pcgmon Lock File ......................................................................................... 63
Appendix G Reset the Password for the admin User 65
Resetting the Password for the admin User ....................................................................... 66
Index 69
iv
About This Guide
About This Guide
Purpose
This PowerKEY CAS Gateway 4.1 Installation and Configuration Guide provides an overview of the PowerKEY® Conditional Access System (CAS) and describes the
PowerKEY CAS Gateway (PCG) server. The PCG is a DVB SimulCrypt-compliant
Entitlement Control Message (ECM) generator (ECMG) that performs real-time
PowerKEY ECM generation. Visit www.cisco.com
( http://www.cisco.com
) for data sheets and white papers describing the benefits and features of the PCG server and its role in the Cisco PowerKEY CAS.
Audience
This document is written for system operators. Field service engineers and Cisco
Services engineers may also find the information in this document helpful.
Required Skills and Expertise
System operators or engineers who upgrade the PCG software need the following skills:
Advanced knowledge of Linux.
Experience with the vi editor. Several times throughout the system upgrade process, system files are edited using the vi editor. The vi editor is not intuitive. The instructions provided in this guide are no substitute for an advanced working knowledge of vi.
The ability to review and edit cron files.
Knowledge of VMware.
Extensive EC, DTACS, PCG and DBDS system expertise.
Migration Paths
There is no supported upgrade path from PCG 4.0 or earlier to PCG 4.1 due to the new operating system on PCG 4.1. All sites running PCG 4.0 or earlier must build a new PCG virtual machine using the current PCG OVA (i.e. PCG-4.1.0-4.ova). v
About This Guide
Supported EC and DTACS Versions
EC :
SR 9.0
SR 8.0
DTACS :
SR 5.2
SR 5.0 vi
1
Chapter 1
System Requirements
Before you deploy the PCG VM, make sure your system environment meets the hardware and software requirements defined in this chapter.
In This Chapter
Hardware Requirements........................................................................ 2
Software Requirements .......................................................................... 3
1
Chapter 1 System Requirements
Hardware Requirements
Cisco UCS C220 M3 or C220 M4 servers with the latest ESXi software installed.
Important : If you are using a new UCS C220 server, refer to Hardware
Configuration Procedures for the Cisco UCS C220 Server (on page 35) for details about configuring the server. This must be completed prior to deploying the
OVA.
Supported PCG Server Platform:
Platform
Cisco UCS C220 M3
Cisco UCS C220 M4
Hard Drive
(GB)
3 x 300
3 x 300
Memory
(GB minimum)
16
64
Cisco UCS hardware should have adequate CPU, memory and hard disk capacities:
CPU
Memory
(GB)
2
Hard Disk
(GB)
1 x 32 (root)
Network Interfaces
1 x Public 2
Network Mapping :
NET0 — vSwitch0 — Controller Network
NET1 — vSwitch1 — Simulcrypt Synchronizer (SCS) Network
2
Software Requirements
Software Requirements
The following software is required for the PCG 4.1 installation.
Requires a vCenter Web UI login or a vSphere client to connect and perform management tasks.
A vCenter login must have admin privileges to deploy VMs.
Reserve two static IP addresses:
One for the network interface to the client (EC/DTACS server).
One for the Simulcrypt Synchronizer (SCS).
Obtain the associated domain name server, default gateway and network mask values from your system administrator.
Download the following software from your customer-specific forum on Cisco's
File Exchange Server and save it to a local directory that is accessible to the vSphere application.
PCG Linux VMware OVA (for example, PCG-4.1.0-4.ova)
PCG Application Package (for example, CSCOec-pcg-4.1.0-4.x86_64.rpm)
3
2
Chapter 2
Install the Software on the
EC/DTACS Server
This chapter provides the procedure to install or upgrade the PCG package to your EC/DTACS system.
Notes :
Make sure the RPM version you plan to install matches the OVA version that will be deployed to build the PCG VM.
If you did not yet download the PCG RPM package to your local system, refer to Software Requirements (on page 3) to do so now.
In This Chapter
Installing the PCG Package on the EC or DTACS Server ................. 6
5
Chapter 2 Install the Software on the EC/DTACS Server
Installing the PCG Package on the EC or DTACS
Server
Complete the following steps to install the PCG package on an EC 9.0/8.0 or a
DTACS 5.2/5.0 server.
1 Copy the CSCOec-pcg package (for example, CSCOec-pcg-4.1.0-4.x86_64.rpm) to the /var/tmp/ directory on your EC/DTACS server.
2 As admin user, log into the EC/DTACS server.
3 Enter the following command to install the CSCOec-pcg package on the
EC/DTACS server. An Is this ok [y/d/N] prompt appears.
Command Syntax : sudo yum install CSCOec-pcg-[VERSION].x86_64.rpm
Example :
[admin@EC/DTACS ~]$ sudo yum install
CSCOec-pcg-4.1.0-4.x86_64.rpm
4 When prompted to confirm the installation, type y and press Enter . The package is downloaded and installed and a Complete message is displayed.
5 Enter the following command to verify the PCG package installation.
[admin@EC/DTACS ~]$ rpm -qi CSCOec-pcg
6
3
Chapter 3
Deploy the PCG Virtual
Machine
This chapter describes how to deploy the PCG virtual machine using the PCG Linux platform OVA that you downloaded to your local PC.
Note : If you did not yet downloaded the PCG OVA to your local system, refer to Software Requirements (on page 3) to do so now.
In This Chapter
Deploying the PCG Virtual Machine from the vSphere Web
UI ............................................................................................................... 8
Reconfiguring the PCG Virtual Hardware .......................................... 9
Power On and Login to the New PCG Virtual Machine ................. 10
Configuring the PCG Network ........................................................... 11
Updating the Time Zone ...................................................................... 14
Installing VMware Tools (Optional) .................................................. 16
7
Chapter 3 Deploy the PCG Virtual Machine
Deploying the PCG Virtual Machine from the vSphere Web UI
Complete the following procedure to deploy the PCG VM using the PCG OVA (for example, PCG-4.1.0-4.ova).
Note : This procedure is written using vSphere vCenter Web Client 6.0.
1 Via a Web browser, login to the vCenter Web UI.
2 Go to the Hosts and Clusters view.
3 Right-click the ESXi host or cluster where you will deploy the PCG VM instance.
4 Select Deploy OVF Template . The Deploy OVF Template > Select source window opens.
5 Click Local file and then click Browse .
6 Navigate to the directory where you saved the PCG OVA file. Select the OVA and click Open . The absolute path of the PCG OVA is displayed next to the
Browse button.
7 Click Next . The Review details window opens.
8 Review the OVF template details and click Next . The Accept License Agreements window opens.
9 Review the End User License Agreement and click Accept . Then click Next . The
Select name and folder window appears.
10 In the Name text box, enter a name that describes the PCG VM.
11 From the Select a folder or datacenter area, select the datacenter where the VM is to be located and click Next . The Select storage window opens.
12 From the Select virtual disk format dropdown menu, select Thick Provision
Lazy Zeroed .
13 Select the appropriate datastore to store the configuration files and all of the virtual disks for the VM.
14 Click Next . The Setup networks window displays.
15 Select the appropriate Destination Network for each Source network. Then click
Next . The Ready to Complete window displays.
16 Review the details and click Finish .
17 Monitor the deployment of the VM from the Recent Tasks area to verify that the
VM successfully deployed.
8
Reconfiguring the PCG Virtual Hardware
Reconfiguring the PCG Virtual Hardware
Complete the following procedure to reconfigure the virtual hardware for the PCG
VM.
1 Right-click the VM and select Edit Settings . The Virtual Machine Properties window displays.
2 From the CPU dropdown menu, select 2 .
3 Verify that Network adapter 1 is connected to the management/controller interface.
4 Verify that Network adapter 2 is connected to the SCS interface for your network.
5 Click OK to reconfigure the VM.
6 Monitor the Recent Tasks area to confirm that the VM virtual hardware is successfully reconfigured.
9
Chapter 3 Deploy the PCG Virtual Machine
Power On and Login to the New PCG Virtual
Machine
Complete the following steps to power on and login to the new PCG VM.
1 Select and right-click the PCG VM and select Power On .
2 Right-click the VM again and select Open Console .
3 Log into the VMware console with the following credentials:
User Name : admin
Password : password
Important : The admin user has full root privileges via the sudo command. Direct root access is not permitted.
4 Press Enter . You are prompted to change the password. Please change it to something appropriate for your environment.
5 At the (current) UNIX password prompt, re-enter the default password which is password .
6 At the New password prompt, enter a new password.
7 At the Retype new password prompt, re-enter the new password. The admin prompt displays.
8 Enter the following command to verify that the PCG package is installed.
[admin@pcg ~]$ rpm -qa | grep -i pcg
Example Output :
CSCOec-pcg-4.1.0-4.x86_64
9 Go to the next section.
10
Configuring the PCG Network
Configuring the PCG Network
Complete the following steps to manually configure the PCG network.
Note : You should be logged into the PCG VM from a Console window.
1 Enter the following command to define a hostname for the PCG server.
Note : Substitute the hostname you want to define for [pcghostname]. Do not include the brackets.
Command Syntax : sudo hostnamectl set-hostname [pcghostname]
Example :
[admin@pcg ~]$ sudo hostnamectl set-hostname pcgtest
2 Enter the following command to reboot the system.
[admin@pcg ~]$ sudo reboot now
3 Log back into the system as admin user. The prompt should now include the hostname you defined in Step 1.
4 Enter the following command to configure the management ( ens192 ) network interface.
[admin@pcgtest ~]$ sudo vi
/etc/sysconfig/network-scripts/ifcfg-ens192
5 Change the BOOTPROTO value to none .
BOOTPROTO=none
6 Go to the end of the file and add the following lines.
Syntax :
Note : Substitute the appropriate values for terms shown in brackets.
IPADDR=[IP_address_PCG_Management_interface]
PREFIX=[[Subnet_PCG_Management_interface]
GATEWAY=[Gateway_PCG_Management_interface]
DEFROUTE=yes
NM_CONTROLLED=no
11
Chapter 3 Deploy the PCG Virtual Machine
Example :
# Created by cloud-init on instance boot automatically, do not edit.
#
BOOTPROTO=none
DEVICE=ens192
HWADDR=00:50:56:b8:15:79
ONBOOT=yes
TYPE=Ethernet
USERCTL=no
IPADDR=204.1.61.100
PREFIX=29
GATEWAY=204.1.61.102
DEFROUTE=yes
NM_CONTROLLED=no
7 Save and close the file.
8 Type the following command to determine the MAC address defined for the ens224 interface.
[admin@pcgtest network-scripts]$ ifconfig ens224
9 Record the MAC address from the output of Step 9. It will be included in the ifcfg-ens224 configuration file.
MAC address for ens224 : ___________________________
10 Type the following command to create the ifcfg-ens224 network interface file.
[admin@pcg network-scripts]$ sudo cp ifcfg-ens192 ifcfg-ens224
11 Open the ifcfg-ens224 file in a text editor.
[admin@pcgtest network-scripts]$ sudo vi ifcfg-ens224
12 Delete the GATEWAY entry.
13 Update the following entries:
Note : Substitute the appropriate values for fields shown in brackets.
DEVICE=ens224
HWADDR=[MAC_address_from_Step_10]
IPADDR=[IP_address_SCS/PKE_interface]
DEFROUTE=no
Example :
# Created by cloud-init on instance boot automatically, do not edit.
#
BOOTPROTO=none
DEVICE=ens224
HWADDR=00:50:56:b8:57:ca
ONBOOT=yes
TYPE=Ethernet
USERCTL=no
IPADDR=140.1.61.100
PREFIX=29
NM_CONTROLLED=no
14 Save and close the file.
15 Enter the following command to restart the network service.
[admin@pcgtest network-scripts]$ sudo systemctl restart network
12
Configuring the PCG Network
16 Enter the following commands, on one line, to verify that the network interfaces and the routing are set up correctly.
[admin@pcgtest network-scripts]$ ifconfig -a ; netstat -nrv
17 Is the network set up correctly?
If no , review the configuration files you set up or contact Cisco Services.
If yes , close the Console window and go to the next step.
18 From a terminal window, log into the EC/DTACS associated with the PCG server as admin user.
19 From the EC/DTACS, SSH into the PCG server as admin user.
Command Syntax : ssh admin@[IP address of PCG server]
Example :
[admin@ec/dtacs ~]$ ssh [email protected]
20 Enter the following command to display the mapping of the network interfaces to MAC addresses.
Important : The MAC addresses shown in this output are examples. The output for your system will be different.
[admin@pcgtest ~]$ ip -o link show | awk '{print $2, $15}'
Example Output : lo: 00:00:00:00:00:00 ens192: 00:50:56:b8:45:5b ens224: 00:50:56:b8:5a:37
21 Record the ens192 MAC address from your output as it is required to configure the PCG via the EC/DTACS Web interface in a later procedure. ens192 : _____________________
13
Chapter 3 Deploy the PCG Virtual Machine
Updating the Time Zone
If desired, complete the following steps to query and change the system clock and its settings.
Note : You should be logged into the PCG server as admin user via SSH from the
EC/DTACS.
1 Enter the following command to view the default date and timezone.
Note : The default timezone is UTC (Coordinated Universal Time).
[admin@pcgtest ~]$ timedatectl
Example Output :
Local time: Thu 2018-09-20 20:52:47 UTC
Universal time: Thu 2018-09-20 20:52:47 UTC
RTC time: Thu 2018-09-20 20:52:47
Time zone: UTC (UTC, +0000)
NTP enabled: yes
NTP synchronized: yes
RTC in local TZ: no
DST active: n/a
2 Do you want to update the timezone?
If yes , go to Step 3.
If no , you have completed this procedure.
3 Enter the following command to determine that proper syntax for your timezone.
[admin@pcgtest ~]$ timedatectl list-timezones
4 Scan through the list to find the entry for your timezone (for example,
America/New_York).
5 Press Ctrl+C to exit the output list.
6 Enter the following command to set the timezone.
Command Syntax : sudo timedatectl set-timezone [timezone_syntax]
Example : using timezone=America/New_York
[admin@pcgtest ~]$ sudo timedatectl set-timezone
America/New_York
14
Updating the Time Zone
7 Repeat Step 1 to confirm the new timezone.
Example :
Local time: Thu 2018-09-20 16:53:07 EDT
Universal time: Thu 2018-09-20 20:53:07 UTC
RTC time: Thu 2018-09-20 20:53:07
Time zone: America/New_York (EDT, -0400)
NTP enabled: yes
NTP synchronized: yes
RTC in local TZ: no
DST active: yes
Last DST change: DST began at
Sun 2018-03-11 01:59:59 EST
Next DST change: DST ends (the clock jumps one hour backwards) at
Sun 2018-11-04 01:59:59 EDT
Sun 2018-11-04 01:00:00 EST
15
Chapter 3 Deploy the PCG Virtual Machine
Installing VMware Tools (Optional)
The installation of VMware Tools is optional. If you wish to install VMware Tools on the PCG machine, follow the instructions provided by VMware.
Installing and Configuring VMware Tools
( https://www.vmware.com/pdf/vmware-tools-installation-configuration.pdf
)
VMware KB 1018414
( http://kb.vmware.com/selfservice/microsites/search.do?language=en_US&cmd= displayKC&externalId=1018414 )
Abbreviated Procedure
Complete the following steps to install VMware Tools.
1 Click the link in vCenter to make the VMware Tools CD available to the PCG
VM.
2 As admin user, enter the following command to change to root user.
[admin@pcgtest ~]$ sudo -i
3 Enter the following command to mount the virtual cdrom.
[root@pcgtest ~]# mount -o ro /dev/cdrom /mnt
4 Enter the following command to change to the /root directory.
[root@pcgtest ~]# cd /root
5 Enter the following command to extract the VMware Tools tar file.
[root@pcgtest ~] ~# tar xzpf /mnt/VMwareTools-*.tar.gz
6 Enter the following command to install the VMware Tools using the default options.
[root@pcgtest ~]# ./vmware-tools-distrib/vmware-install.pl -d
16
4
Chapter 4
Provision the PCG on the
EC/DTACS Web UI
This chapter includes the procedures to provision the PCG VM on the
EC/DTACS Web UI. Once the PCG is configured in the Web UI, the
PCG is reset. During the reset, the EC/DTACS server responds by provisioning the PCG according to the new settings.
Note : Ethernet settings can be used to communicate with the SCS, which can provision the PCG with scrambler or SCS device IP addresses and parameters (for example, maximum number of scrambling control groups (SCGs)).
In This Chapter
Provisioning the PCG on the EC Web UI .......................................... 18
Provisioning the PCG on the DTACS Web UI .................................. 22
17
Chapter 4 Provision the PCG on the EC/DTACS Web UI
Provisioning the PCG on the EC Web UI
Complete the following procedure to provision the PCG on the EC Web UI.
1 As dncs user on the EC, type the following command to monitor the bootp log.
Note : You will actually monitor this log after provisioning the PCG on the EC
Web UI later in this procedure.
[dncs@ecnextx root]$ qtail bootp
2 Enter the appropriate values in the following table as they are required to provision the PCG on the EC.
Notes :
The Control IP address, subnet mask and default gateway fields represent the ens192 interface.
The SCS IP address and subnet mask fields represent the ens224 interface.
The PCG ens192 MAC address was recorded in Configuring the PCG
Network (on page 11).
Parameter
Control IP Address
Control Subnet Mask
Control Default Gateway
SCS IP Address
SCS Subnet Mask
Value
Control MAC Address
(ens192)
3 From a supported web browser, login into the EC Web UI as an administrative user (for example, ecadmin).
4 Click the Navigation button ( ) and then select Network Element Provisioning
> PCG . The Powerkey CAS Gateway List Web UI displays.
Important : The PCG feature must be enabled as a licensed feature. If PCG is not yet enabled, contact Cisco Services.
5 Click Add . The Add PowerKEY CAS Gateway window displays and the Basic
Parameters display by default.
18
Provisioning the PCG on the EC Web UI
6 Update the fields for your PCG system.
Note : Some of the values are documented in Step 2.
Field
Name
Session Resource
Identifier
Sub-CAS ID
Headend
Status
Control Interface IPv4
Address
Control Interface Subnet
Mask
Control Interface MAC
Address
Control Interface Default
Gateway
SCS Interface IPv4
Address
SCS Interface Subnet
Mask
Config File
Description
A unique name for the PCG
A unique identifier for the PCG.
Note : This can be the same as the entry in the
Name field.
Default is 0x0
Select the appropriate headend
Set the status to Offline or Online
The IP address of the Control interface (ens192) on the PCG
The subnet mask of the Control interface
(ens192) on the PCG
The MAC address of the Control interface
(ens192) on the PCG
The default gateway of the Control interface
(ens192) on the PCG
The IP address of the SCS interface (ens224) on the PCG
The subnet mask of the SCS interface (ens224) on the PCG
The name of the PCG application configuration file. This file is installed, when the PCG application is installed on the EC. The default is pcg.cfg
19
Chapter 4 Provision the PCG on the EC/DTACS Web UI
Example :
7 Click the Advanced Parameters tab. The Advanced Parameters window displays.
8 Define the following values for the fields shown below.
Field
ECM Delivery Mode
Description
Select MPEG2 PacketFormat
Default Scrambling Mode Select PowerKEY DES
Example :
20
9 Click Save . You are returned to the PowerKEY CAS Gateway List window. The
PCG is displayed in the list.
10 In the terminal window where you are monitoring bootp (Step 1), observe the output to verify that the PCG is successfully provisioned.
Provisioning the PCG on the EC Web UI
11 When you have verified the bootp for the PCG device, enter Ctrl+C to exit the qtail session.
Note : If boot issues are present, refer to Troubleshooting Boot Issues (on page
62).
21
Chapter 4 Provision the PCG on the EC/DTACS Web UI
Provisioning the PCG on the DTACS Web UI
Complete the following procedure to provision the PCG on the DTACS Web UI.
1 As dncs user on the DTACS, type the following command to monitor the bootp log.
Note : You will actually monitor this log after provisioning the PCG on the
DTACS Web UI later in this procedure.
[dncs@dtacs root]$ qtail bootp
2 Enter the appropriate values in the following table as they are required to provision the PCG on the DTACS.
Important :
The Control IP address, subnet mask and default gateway fields represent the ens192 interface.
The SCS IP address and subnet mask fields represent the ens224 interface.
The PCG ens192 MAC address was recorded in Configuring the PCG
Network (on page 11).
Parameter
Control IP Address
Control Subnet Mask
Control Default Gateway
SCS IP Address
Value
SCS Subnet Mask
Control MAC Address
(ens192)
3 Login to the DTACS Web UI as an administrative user (for example, dtacsadmin).
4 Click the Navigation button, , and then select Network Elements > PCG .
Important : The PCG feature must be enabled as a licensed feature. If PCG is not yet enabled, contact Cisco Services.
5 Click Add . The SCC CAS Gateway List window display and the Basic
Parameters display by default.
22
Provisioning the PCG on the DTACS Web UI
6 Update the fields for your PCG system.
Note : Some of the values were recorded in Step 2.
Field
Name
Session Resource
Identifier
Sub-CAS ID
Headend
Status
Control Interface IPv4
Address
Control Interface Subnet
Mask
Control Interface MAC
Address
Control Interface Default
Gateway
SCS Interface IPv4
Address
SCS Interface Subnet
Mask
Config File
Description
A unique name for the PCG
A unique identifier for the PCG.
Note : This can be the same as the entry in the
Name field.
Default is 0x0
Select the appropriate headend
Set the status to Offline or Online
The IP address of the Control interface on the
PCG (ens192)
The subnet mask of the Control interface on the
PCG
The MAC address of the Control interface
(ens192) on the PCG
The default gateway of the Control interface on the PCG (ens192)
The IP address of the SCS interface (ens224) on the PCG
The subnet mask of the SCS interface (ens224) on the PCG
The name of the PCG application configuration file. This file is installed, when the PCG application is installed on the DTACS. The default is pcg.cfg
23
Chapter 4 Provision the PCG on the EC/DTACS Web UI
Example :
24
7 Click the Advanced Parameters tab. The Advanced Parameters window displays.
8 Define the following values for the fields shown below.
Field
ECM Delivery Mode
Description
Select MPEG2 PacketFormat
Default Scrambling Mode Select PowerKEY DES
Example :
Provisioning the PCG on the DTACS Web UI
9 Click Save . You are returned to the SCC CAS Gateway List window. The PCG you provisioned and saved appears in the list.
10 In the terminal window where you are monitoring bootp (Step 1), observe the output to verify that the PCG is successfully provisioned.
11 When you have verified the bootp for the PCG device, enter Ctrl+C to exit the qtail session.
Note : If boot issues are present, refer to Troubleshooting Boot Issues (on page
62).
25
5
Chapter 5
Verify PCG Versions
This chapter describes the procedures to verify the PCG version from the EC and the DTACS servers, as well as from the PCG server.
In This Chapter
Verifying PCG Package Versions on the EC/DTACS ..................... 28
Verifying the PCG Version on the PCG Server ................................ 29
27
Chapter 5 Verify PCG Versions
Verifying PCG Package Versions on the EC/DTACS
Important : The EC/DTACS dictates what PCG version should be loaded on the PCG servers.
Complete the following steps to verify the PCG version installed on the EC/DTACS server.
1 From the EC/DTACS terminal window, enter the following command to verify the version of the PCG package currently installed.
EC/DTACS:
[admin@ec/dtacs ~]$ rpm -qa | grep -i pcg
Example Output :
CSCOec-pcg-4.1.0-4.x86_64
2 To determine the PCG version on the PCG server, go to the next section.
28
Verifying the PCG Version on the PCG Server
Verifying the PCG Version on the PCG Server
Important : Do NOT use the rpm command to verify the version of the PCG package as the output of the rpm command only reflects the PCG version loaded during initial installation. Therefore, it may not match the actual version of the PCG code that is running.
Complete the following steps to determine the current version of the PCG application installed on the PCG server.
1 From the EC/DTACS, SSH into the PCG server as admin user.
2 Enter the following command to access the PCG console application.
[admin@pcgtest ~]$ sudo /opt/pcg/console_app/cons
3 At the PCG> prompt, enter the following command to verify the version of the
PCG package currently installed. vers
Example Output :
PCG> PCG version: 4.1.0-4. Build date : 27 August 2018
Result: The PCG version on the EC/DTACS and the PCG server should match.
4 Press Enter to return to the PCG console application prompt.
5 Type exit to return to the PCG prompt.
6 Did the output from Step 2 match the PCG version on the EC/DTACS server?
If yes , you have completed this procedure.
If no , go to Upgrade the PCG Server (on page 49).
29
6
Chapter 6
Configure SNMPv2
Simple Network Management Protocol (SNMP) is an Internetstandard protocol for collecting and organizing information about managed devices on IP networks.
This chapter describe how to configure SNMPv2 and SNMPv3 for the
PCG device.
In This Chapter
Configuring SNMPv2 ........................................................................... 32
Configuring SNMPv3 ........................................................................... 33
31
Chapter 6 Configure SNMPv2
Configuring SNMPv2
Complete the following procedure to configure SNMPv2 on the PCG.
1 If you are not logged into the PCG, ssh into the PCG server as admin user.
2 Enter the following command to edit the /etc/snmp/snmpd.conf
file.
[admin@pcgtest ~]$ sudo vi /etc/snmp/snmpd.conf
3 Move to the end of the file and add the following three lines.
Notes :
Replace [PCG ens192 IP] with the IP address of the ens192 network interface.
Replace [community_name] with the desired SNMP community name.
Replace [destination_host]:[port] with the IP address and port of the SNMP trap listener.
Line Syntax : agentaddress [PCG ens192 IP]:161 rocommunity [community_name] trapsess -v2c -c [community_name][destination_host]:[port]
Example : agentaddress 204.1.61.100:161 rocommunity public trapsess -v2c -c public 204.123.1.33:162
4 Save and close the file.
5 Enter the following command to stop the SNMP service.
[admin@pcgtest ~]$ sudo systemctl stop snmpd
6 Enter the following command to start the SNMP service.
[admin@pcgtest ~]$ sudo systemctl start snmpd
7 Enter the following command to verify that the SNMP service is running.
[admin@pcgtest ~]$ sudo systemctl status snmpd
32
Configuring SNMPv3
Configuring SNMPv3
Creating the SNMPv3 User
Complete the following steps to create a SNMPv3 user.
Note : Refer to the SNMP RFCs for SNMPv3 username and passphrase constraints.
1 Enter the following command to stop the SNMP service.
[admin@pcgtest ~]$ sudo systemctl stop snmpd
2 Enter the following command to create the SNMPv3 user.
[admin@pcgtest ~]$ sudo /usr/bin/net-snmp-create-v3-user
3 When prompted for SNMPv3 user name, enter a user name and press Enter .
4 When prompted for an authentication password, enter a password and press
Enter .
Important : The authentication password must be at least 8 characters and can include alphabetic, numeric, and special characters, but it cannot include control characters.
5 When prompted for an encryption pass-phrase, either type a password and press
Enter or press Enter to use the same password as the authentication password.
Important : If you define a unique password it must be at least 8 characters and can include alphabetic, numeric, and special characters. It cannot include control characters.
Result : The /var/lib/net-snmp/snmpd.conf is updated and the SNMPv3 user is created.
Changing the SNMPv3 User Options
1 Open the /etc/snmp/snmpd.conf
file and go to the end of the file to the rwuser line.
Note : The SNMPv3 user name you created will be at the end of the rwuser line.
[admin@pcgtest ~]$ sudo vi /etc/snmp/snmpd.conf
2 Go to the end of the line and add authPriv after the new username entry. rwuser Entry Syntax : rwuser [snmp_username]
Example : rwuser snmpuser authPriv
3 Next, change rwuser to rouser . This allows read-only SNMP operations. rwuser Entry Syntax : rwuser [snmp_username] authPriv
33
Chapter 6 Configure SNMPv2
Example : rouser snmpuser authPriv
4 Save and close the snmpd.conf
file.
5 Enter the following command to verify the authPriv entry.
[admin@pcgtest ~]$ sudo less /etc/snmp/snmpd.conf | grep -i priv
Example Output : rouser snmpuser authPriv
Restart the SNMP Service
1 Enter the following command to start the SNMP service.
[admin@pcggtest ~]$ sudo systemctl start snmpd
2 Enter the following command to verify that the SNMP service is running.
[admin@pcgtest ~]$ sudo systemctl status snmpd
Defining the SNMPv3 Trap Destination
Complete the following steps to define the SNMPv3 trap destination.
1 Enter the following command to stop the SNMP service.
[admin@pcgtest ~]$ sudo systemctl stop snmpd
2 Add the following line to the /etc/snmpd/snmpd.conf
file.
Notes :
Replace <username> with the SNMPv3 username.
Replace <trapDestIP> with the IP address of the SNMP trap receiver.
Replace <trapDestPort> with the port number of the SNMP trap receiver
(typically 162). The -l option can be set to noAuthNoPriv, authNoPriv, or authPriv but is recommended to be authPriv.
Replace <authProt> with the authentication protocol defined for the SNMPv3 user: MD5 or SHA.
Replace <privProt> with the encryption (privacy) protocol defined for the
SNMPv3 user: DES or AES.
Line Syntax : trapsess -v3 -u [username] -l authPriv -a [authProt] -x
[privProt] [trapDestIP]:[trapDestPort]
Example :
[admin@pcgtest ~]$ sudo trapsess -v3 -u snmp -l authPriv -a
SHA -x DES 204.123.1.33:162
3 Enter the following command to start the SNMP service.
[admin@pcgtest ~]$ sudo systemctl start snmpd
34
A
Appx auto letter
Appendix A
Hardware Configuration
Procedures for the Cisco UCS
C220 Server
This appendix describes the server hardware and explains how to configure it for initial use with the PCG system.
In This Appendix
Cisco UCS C220 Server Diagram ........................................................ 36
Cisco UCS C220 Server CIMC Configuration ................................... 38
RAID Configuration ............................................................................. 40
35
Appendix A
Hardware Configuration Procedures for the Cisco UCS C220 Server
Cisco UCS C220 Server Diagram
Chassis Front View
The following diagram displays the chassis front view of the Cisco UCS C220 Server.
36
7
8
9
3
4
5
6
Field
1
2
10
Description
Power button or power status LED
Identification button or LED
System status LED
Fan status LED
Temperature status LED
Power supply status LED
Network link activity LED
Pull-out asset tag
KVM connector (used with KVM cable that provides two USBs, one VGA, and one serial connector)
Drives hot-swappable (up to eight 2.5-inch drives)
Cisco UCS C220 Server Diagram
Chassis Rear View
The following diagram displays the chassis rear view of the Cisco UCS C220 server.
Note : Only the essential features of the rear panel are shown in this image. Also, be certain that the network cards are installed in the slots as shown in this diagram.
3
7
8
9
4
5
6
Field
1
2
Description
Power supplies
Low-profile PCIe slot 2 on riser (half-height, halflength, x8 lane)
Standard-profile PCIe slot on riser (full-height, halflength, x16 lane)
VGA video connector
Serial port (RJ-45 connector)
1-Gb Ethernet dedicated management port
Dual 1-Gb Ethernet ports (LAN1 and LAN2)
USB ports
Rear identification button or LED
Detailed View of PCI Ports
The following diagram shows the detailed view of the PCI Ports.
Note : For the PCIe1 card, the top row contains ports 2, 3, 4, and 5, the bottom row contains ports 0 and 1.
37
Appendix A
Hardware Configuration Procedures for the Cisco UCS C220 Server
Cisco UCS C220 Server CIMC Configuration
Notes :
The CIMC firmware and BIOS version should be at or higher than the minimum required version shown in Tested Reference Configuration section located in the
Preface (on page v). If it does not meet these requirements, contact Cisco Services for assistance in upgrading the firmware and the BIOS.
You have to perform this procedure only once, that is, when you initially install the UCS C220.
Be sure that you use configuration data that pertains to the system that you are migrating.
Complete the following steps to configure the Cisco UCS C220 server.
1 Follow the instructions in the UCS C220 Server Installation and Service Guide .
This guide is shipped with the server.
2 Press the Power button to power on the UCS C220 server.
3 Press F8 at the Cisco splash screen. The server boots to the CIMC Configuration
Utility window.
Important : Note the BIOS version on the Cisco splash screen as the system is booting.
4 Use the information in the CIMC Configuration Utility window to complete the configuration.
Note : In addition to the information in the CIMC Configuration Utility window, be sure to obtain the network IP address for the CIMC interface.
Important : The following image is an example only. Do not use the IP address, netmask, or gateway in the image.
38
Cisco UCS C220 Server CIMC Configuration
5 Enter a default password and re-enter it at the prompt.
Note : Store this password in a safe place for future use.
6 Press F10 to save changes.
7 Press Esc to exit. The EFI shell prompt may appear.
39
Appendix A
Hardware Configuration Procedures for the Cisco UCS C220 Server
RAID Configuration
Important : This procedure only needs to be performed once — when you initially install the UCS C220 server.
Go to the appropriate section to configure RAID on your UCS hardware.
Configuring RAID for UCS C220 M3 Servers (on page 40)
Configuring RAID for UCS C220 M4 Servers (on page 42)
Configuring RAID for UCS C220 M3 Servers
The UCS hardware RAID configuration for this system release consists of a RAID 1 for the OS disk and one global hot spare (3x300GB).
Complete the following steps to create these volumes and hot spares.
1 Press Ctrl-Alt-Del to reboot the server.
2 Monitor the reboot process closely. After the disks are displayed, observe the boot messages and press Ctrl-H when prompted to access the WebBIOS (RAID
Configuration Utility). After a few minutes, a Start button appears.
3 Click Start to configure RAID. The MegaRAID BIOS Config Utility main menu appears.
4 Click the Configuration Wizard link in the left area of the utility menu.
5 Click New Configuration and then click Next . The utility prompts you to clear the existing configuration.
6 Click Yes .
7 Click Manual Configuration and then click Next . The Drive Group Definition screen appears.
Note : In the drives panel, there is a list of all three hard drives. Create two drive groups, the first consisting of two disks (1 and 2) and the second consisting of one global hot spare drive.
8 Select the Slot 0 disk and while pressing the Ctrl key, click the Slot 1 disk to highlight both disks.
9 Click Add to Array to form Drive Group (0).
10 Click Accept DG .
11 Click Next and select Drive Group 0 .
12 Click Add to SPAN to Drive Group 0 to the span list.
13 Click Next . The Virtual Drive Definition window appears.
14 Select RAID 1 from the RAID Level dropdown menu.
40
RAID Configuration
15 Click Update Size . The maximum allowed size for the selected RAID level populates the Select Size field and records the size.
16 Click Accept . The Write Policy window appears.
17 Click Yes to confirm the default write policy.
18 Click Back and then select Drive Group 0 .
19 Click Add to SPAN to Drive Group 1 to the span list.
20 Click Next . The Virtual Drive Definition window appears.
21 Select RAID 1 from the RAID Level drop-down menu.
22 Click Update Size . The maximum allowed size for the selected RAID level populates the Select Size field and records the size.
23 Click Accept . The Write Policy window appears.
24 Click Yes to confirm the default write policy. The total list of Vdisks created from
Drive Groups 0 to 1 appears.
25 Click Next .
26 Examine the configuration preview to verify that the virtual drives match the previous list and select Accept . The system prompts to confirm that you want to save the configuration.
27 Click Yes . A warning message appears and indicates that you may lose data.
Note : If you cancel the previous screen, you will be prompted to initialize the new virtual drives.
28 Click Yes to initialize. The Virtual Drive VD0 is displayed.
29 Click Home . The Raid Configuration utility main menu appears.
30 Click the Physical View from the left pane if it is not currently displayed.
31 Click Back and then repeat Steps 21 through 22 for the drive in Slot 16.
32 Click Home and select the Physical View (if it is not displayed by default).
33 From the Main Menu, click Exit to exit the RAID Configuration Utility.
34 Click Yes to confirm that you want to exit the utility.
41
Appendix A
Hardware Configuration Procedures for the Cisco UCS C220 Server
Configuring RAID for UCS C220 M4 Servers
Complete the following steps to configure RAID for a C220 M4 UCS server.
1 Power on the Cisco UCS C220 M4 server.
Note : If the server is already powered on, reboot the server.
2 On boot up, press CTRL+R to enter the Cisco 12G SAS Modular Raid Controller
BIOS Configuration Utility.
42
3 Press CTRL+N and then click the PD Mgmt tab.
4 Use the UP or DOWN arrow keys to move between the disks.
5 Complete the following steps to change the disks from Just a Bunch Of Disks
(JBOD) to Unconfigured Good (UG) . a Select the first disk and press F2 . b Select Make unconfigured good . c When prompted to confirm the change, click Yes and press Enter . The state of the drive will change from JBOD to UG.
RAID Configuration d Repeat Steps 4a through 4c for remaining drives.
6 Go back to the VD Mgmt tab and press CTRL+P .
7 Select No Configuration Present and press Enter .
8 Configure the following: a From the RAID Level area, select RAID-1 . b From the Secure VD area, select No . c From PD per Span area, enter 2 . d From the Drives area, use the UP or DOWN arrow to highlight the appropriate drive and press Enter . An X displays next to the drive to indicate that it is selected. e Repeat Step 8d to select the next drive that will make up this drive pair.
9 Go to the Advanced option and highlight the Initialize option.
10 Press Enter . An X is inserted next to Initialize to indicate that it is selected.
11 Click Ok .
12 Click Ok to close the Advanced option window. The Configuration window is displayed.
13 Click Ok and system will now initialize the RAID-1 array. Wait for the initialization to complete.
14 Click Ok after the Confirmation window indicates that the initialization is complete.
15 Click CTRL+N to return to the PD Mgmt window.
16 From the PD Mgmt window, use the UP or DOWN arrows to highlight the UG drive .
.
43
Appendix A
Hardware Configuration Procedures for the Cisco UCS C220 Server
17 Press F2 and then select Make Global HS .
Note: The state of the drive changes from UG to Hotspare .
18 Press ESC and click Ok to exit the utility.
19 Click the Macros tab and select Static Macros > CTRL+ALT+DEL to reboot the server.
Note : The server must be rebooted for the changes to go into effect.
44
B
Appx auto letter
Appendix B
Backup and Restore Keyfiles
Due to the possibility of a catastrophic event (for example, hardware failure), it is important to create backups of the keyfiles on your PCG server. This will enable you to restore them in the event they are lost, damaged or inaccessible.
This chapter provides the procedures to backup and restore keyfiles. It is recommended that you backup and restore the following files:
/opt/pcg/mon_app/mon.cfg
/etc/snmp/snmpd.conf
In This Appendix
Backing Up Keyfiles ............................................................................. 46
Restoring Keyfiles to a Recovered System ........................................ 47
45
Appendix B
Backup and Restore Keyfiles
Backing Up Keyfiles
Complete the following steps to back up the keyfiles.
1 From the EC/DTACS terminal window. SSH into the PCG server as admin user.
2 As root user, enter the following command to change to the /opt directory.
[root@pcgtest ~]# cd /opt
3 Enter the following command to create a pcgbkup-[PCG_IP] directory.
Command Syntax : mkdir /pcgbkup-[PCG_IP]
Example :
[root@pcgtest opt]# mkdir /pcgbkup-204.1.61.37
4 Copy the following key files to the pcgbkup-[PCG_IP] directory.
/opt/pcg/mon_app/mon.cfg
/etc/snmp/snmpd.conf
5 Execute the following command to create a tar ball.
Command Syntax : tar cvf pcgbkup-[PCG_IP].tar pcgbkup-[PCG_IP]
Example :
[root@pcgtest opt]# tar cvf pcgbkup-204.1.61.100.tar pcgbkup-204.1.61.100
6 Using scp, copy the tar file to a different server or NAS device.
Command Syntax : scp pcgbkup-[PCG_IP].tar admin:[NAS_IP]:[directory_on_EC/DTACS]
Example :
[root@pcgtest opt]# scp pcgbkup-204.1.61.100.tar admin:10.90.181.146:/var/tmp
46
Restoring Keyfiles to a Recovered System
Restoring Keyfiles to a Recovered System
Complete the following steps to restore the keyfiles to a recovered PCG system.
1 Refer to the Deploy the PCG Virtual Machine (on page 7) to deploy a new PCG server.
2 Complete the following steps to restore the keyfiles from the server where you backed the files up to the PCG server. a From the EC/DTACS terminal window, SSH into the newly installed PCG server as admin user. b As root user, copy the pcgbkup-[PCG_IP].tar file from the backup server to the PCG server.
Command Syntax : scp admin:[NAS_IP]:[directory_on_NAS]/pcgbkup-[PCG_IP].tar
[directory_on_PCG]
Example :
[root@pcgtest opt]# scp admin:10.90.181.146:/var/tmp/pcgbkup-204.1.61.100.tar
/var/tmp c Enter the following command to untar the /opt/pcgbkup-[PCG_IP].tar file.
Command Syntax : tar -xvf /var/tmp/pcgbkup-[PCG_IP].tar
Example :
[root@pcgtest ~]# tar -xvf
/var/tmp/pcgbkup-204.1.61.100.tar
d Type ls -ltr /var/tmp to view the list of keyfiles. e Copy the keyfiles to the appropriate locations.
Command Syntax : cp [directory_location]/mon.cfg /opt/pcg/mon_app cp [directory_location]/snmpd.conf /etc/snmp
Example :
[root@pcgtest ~]# cp /var/tmp/mon.cfg /opt/pcg/mon_app
[root@pcgtest ~]# cp /var/tmp/snmpd.conf /etc/snmp
47
Appendix B
Backup and Restore Keyfiles
3 Login to the EC/DTACS Web UI and access the PCG Web UI by executing the appropriate action. The PCG List window displays.
EC : Network Element Provisioning > PCG
DTACS : Network Elements > PCG
4 From the PCG List Web UI, select the appropriate PCG and click Edit .
5 Update the Control MAC Address and then click Save .
6 Return to the PCG List window and select the PCG again; then click Reset .
7 Verify the PCG version on the EC/DTACS server, as well as on the PCG server.
Refer to Verifying PCG Package Versions on the EC/DTACS (on page 28) for details.
48
C
Appx auto letter
Appendix C
Upgrade the PCG Server
This appendix describes the procedures to upgrade the PCG application. The PCG package is only upgraded on the EC/DTACS server by updating the CSCOec-pcg rpm.
Important : The PCG application cannot be upgraded from the PCG server. You must upgrade the EC/DTACS server and then reboot the
PCG to obtain the current PCG code.
In This Appendix
Upgrading the PCG Package on the EC/DTACS System............... 50
Upgrading the PCG Package on the PCG Server ............................. 51
49
Appendix C
Upgrade the PCG Server
Upgrading the PCG Package on the EC/DTACS
System
Complete the following steps to upgrade the PCG package (CSCOec-pcg) on an EC
9.0/8.0 or DTACS 5.2/5.0 system.
1 Refer to Appendix D in the Admin Node 2.0 User's Guide for procedures to upgrade the software repo with the PCG RPM package.
Important : The software repo must be updated before continuing with the next step.
2 Login to the EC/DTACS server as admin user.
3 Enter the following command to upgrade the PCG application.
[admin@ec/dtacs ~]$ sudo yum update CSCOec-pcg
Result : The upgrade process starts and after running various checks, displays a
"Transaction Summary".
4 When prompted to confirm the upgrade, type y and press Enter . The PCG package is upgraded and a Complete! message displays.
5 Enter the following command to verify that the PCG package was successfully upgraded.
[admin@ec/dtacs ~]$ rpm -qa CSCOec-pcg
6 Go to the next section.
50
Upgrading the PCG Package on the PCG Server
Upgrading the PCG Package on the PCG Server
Important : Once the PCG server is initially installed, you cannot upgrade the PCG application directly from the PCG. You must upgrade the PCG package on the
EC/DTACS and then reboot the PCG server to pull the new code.
Complete the following steps to upgrade the PCG package on the PCG 4.1 server.
1 If you have not yet upgraded the PCG package on the EC/DTACS, go to the previous section to do so now.
2 After upgrading the EC/DTACS server, SSH into the PCG server as admin user.
3 Enter the following command to reboot the PCG server. The PCG SSH session closes and you are returned to the EC/DTACS session.
[admin@pcgtest ~]$ sudo reboot now
4 After a few minutes, SSH back into the PCG server as admin user from the
EC/DTACS.
5 Enter the following command to access the PCG console application.
[admin@pcgtest ~]$ sudo /opt/pcg/console_app/cons
6 At the PCG> prompt, enter the following command to verify the version of the
PCG package currently installed.
PCG> vers
Example Output :
PCG> PCG version: 4.1.0-4. Build date : 27 August 2018
Result: The PCG version on the EC/DTACS and the PCG server should match.
7 Press Enter to return to the PCG console application prompt.
8 Type exit to return to PCG prompt.
51
D
Appx auto letter
Appendix D
Manually Configure the PCG
Network
This appendix explains how to manually configure the PCG network.
In This Appendix
Manually Configuring the PCG Network ......................................... 54
53
Appendix D
Manually Configure the PCG Network
Manually Configuring the PCG Network
Complete the following steps to manually configure the PCG network.
1 Depending on the server where the PCG is associated, enter one of the following commands.
EC 9.0/8.0
:
[admin@ec/dtacs ~]$ less /etc/hosts | grep dncsatm
DTACS 5.2/5.0
:
[admin@ec/dtacs ~]$ less /etc/hosts | grep dtacsatm
2 Record the IP addresses from Step 1 below: dncsatm/dtacsatm : _________________________
3 Enter the following command on the EC/DTACS to change to the tftpboot directory.
[admin@ec/dtacs ~]$ cd /var/lib/tftpboot
4 Enter the following command to secure copy the pcg file to the PCG server.
Command Syntax : scp pcg admin@[PCG_IP]:/opt/pcg/pcg_app/app
Example :
[admin@ec/dtacs ~]$ scp pcg [email protected]:/opt/pcg/pcg_app/app
5 Enter the following command to secure copy the pcg.cfg
file to the PCG server.
Command Syntax : scp pcg.cfg admin@[PCG_IP]:/opt/pcg/pcg_app/app
Example :
[admin@ec/dtacs ~]$ scp pcg.cfg [email protected]:/opt/pcg/pcg_app/app
6 From the EC/DTACS terminal window, SSH to the PCG server as admin user.
7 Enter the following command to change the access rights of the pcg and the pcg.cfg files to 755 .
[admin@pcgtest ~]$ sudo chmod 755 /opt/pcg/pcg_app/app/pcg
/opt/pcg/pcg_app/app/pcg.cfg
8 Enter the following command to change the ownership of the pcg and the pcg.cfg files to root:root .
[admin@pcgtest ~]$ sudo chown root:root
/opt/pcg/pcg_app/app/pcg /opt/pcg/pcg_app/app/pcg.cfg
9 Open the mon.cfg
file in a text editor.
[admin@pcgtest ~]$ sudo vi /opt/pcg/mon_app/mon.cfg
10 Go to the skip-bootp line and change the value from no to yes .
54
Manually Configuring the PCG Network
11 Save and close the mon.cfg
file.
12 Open the pcg.cfg
file in a text editor.
[admin@pcgtest ~]$ sudo vi /opt/pcg/pcg_app/app/pcg.cfg
13 Make the following changes in the pcg.cfg
file.
RpcServerIPAddr : enter the appropriate IP address recorded in Step 2
AlarmServerIPAddr : enter the appropriate IP address recorded in Step 2
ForceDownload : change the value to no
Add the following lines to the end of the file:
– PcgScsInterface = ens224
– PcgtoDncsIfIPAddr : append the IP address for the PCG interface that communicates to the EC/DTACS
14 Save and close the pcg.cfg
file.
15 Open the ifcfg-ens192 file in a text editor and edit the following fields.
[admin@pcgtest ~]$ sudo vi
/etc/sysconfig/network-scripts/ifcfg-ens192
BOOTPROTO : set to Static
IPADDR : append the IP address of the PCG interface that communicates with the EC/DTACS
NETMASK : append the subnet mask of the PCG interface that communicates with the EC/DTACS
ONBOOT : set to yes
16 Save and close the ifcfg-ens192 file.
17 Open the ifcfg-ens224 file in a text editor and edit the following fields.
[admin@pcgtest ~]$ sudo vi
/etc/sysconfig/network-scripts/ifcfg-ens224
BOOTPROTO : set to Static
IPADDR : append the IP address of the PCG interface that communicates with the SCS on private network
NETMASK : append the subnet mask of the PCG interface that communicates with the SCS on private network
ONBOOT : set to yes
55
Appendix D
Manually Configure the PCG Network
18 Save and close the ifcfg-ens224 file.
19 Enter the following command to edit the /etc/sysconfig/network-scripts/routeens192 file.
Note: Substitute the IP address of the gateway that the PCG uses to communicate with the EC/DTACS for [PCG_IP_gw].
Command Syntax : sudo default via [PCG_IP_gw] dev ens192
Example :
[admin@pcgtest ~]$ sudo default via 204.1.61.37 dev ens192
20 Enter the following command to edit the /etc/sysconfig/network-scripts/routeens224 file.
Note: Substitute the gateway that the PCG uses to communicate with the SCS on a private network.
Command Syntax : sudo [network/subnet_mask] via [PCG_IP_gw] dev ens224
Example :
[admin@pcgtest ~]$ sudo 204.1.61.100/30 via 204.1.61.102 dev ens192
21 Enter the following command to restart the network.
[admin@pcgtest ~]$ sudo systemctl restart network
56
E
Appx auto letter
Appendix E
Deliver ECMs to DHCTs
This appendix describes how the PowerKEY ECMs are delivered to the DHCTs. The process begins with system initialization and proceeds to the EC/DTACS server. The SCS or scrambler interactions are outlined below.
The PCG is fully configured and provisioned.
The EC/DTACS server creates sessions on the PCG.
The SCS establishes a TCP connection, channel and valid streams on the PCG.
The PCG responds with ECM streams for existing sessions/services setup by the EC/DTACS server on the PCG.
In This Appendix
Delivering ECMs ................................................................................... 58
57
Appendix E
Deliver ECMs to DHCTs
Delivering ECMs
Complete the following steps to deliver ECMs to DHCTs.
1 When the PCG powers up, configure it manually or using BOOTP. The SCSfacing port receives its network address and the PCG application is launched.
Result : The PCG sends a provision request to the EC/DTACS server. When the
EC/DTACS server receives the request, it sends the PCG a provision response.
The response contains data that sets the EC-facing network address for communication with the scrambler device(s).
Optional : The response may inform the PCG about how many devices can communicate with the PCG, provide their IP addresses, and indicate how many programs can be serviced on each device.
Note : The PCG can support a maximum of 3000 sessions.
2 Create a session from the EC/DTACS Web UI. This provides the access criteria for the PCG service.
Note : If you are using ROSA for access criteria management, then configure the
EIS or Access Criteria Manager Component (ACMC) through the ROSA element manager. Ensure the access criteria specified here match the access criteria explicitly administered on the EC/DTACS source definition Web UI for the associated service or program. Access criteria can be configured through the
ACMC.
A single channel over a TCP connection serves multiple programs. When a program is scheduled for scrambling, the SCS sets up a stream for the program. The scrambler issues access criteria and control words to the PCG for the session, and the PCG responds with the ECMs.
The SCS then sends the ECMs and the scrambled program (with the corresponding control word) to the built-in modulator. From there it goes to the RF and then to the set-top.
Note : If the PCG communicates with an SCS device that does not have a built-in modulator, then a separate modulator is needed to provide RF.
Notes :
PCG scrambling modes are changed in the EC/DTACS to support the new modes added for AES-128 scrambling.
EC and DTACS support configuring PCG scramble mode for the following AES modes:
AES-ECB-CTS
ATIS-IIF-DSA
AES-NSA (or AES-DVB-LSA-CBC-MDI)
58
Delivering ECMs
59
F
Appx auto letter
Appendix F
Troubleshoot PCG Issues
This appendix provides some basic troubleshooting tips for potential issues related to the PCG.
In This Appendix
Troubleshooting Boot Issues ............................................................... 62
Removing the pcgmon Lock File ........................................................ 63
61
Appendix F
Troubleshoot PCG Issues
Troubleshooting Boot Issues
If boot issues are present, refer to the following files to assist you in troubleshooting the issue.
PCG :
/var/log/mon.log
EC :
/dvs/dncs/bin/bootpd
/var/log/dncsLog
DTACS :
/dvs/dtacs/bin/bootpd
/var/log/dncsLog
62
Removing the pcgmon Lock File
Removing the pcgmon Lock File
A common issue can occur when the PCG server is rebooted without properly shutting down the PCG processes. The issue is that a pcgmon lock file is created and prevents the pcgmon process from starting.
Complete the following steps to remove the PCG application lock file from the PCG.
1 Enter the following command in a PCG terminal window to manually start the pcgmon service.
[admin@pcgtest ~]$ sudo systemctl start pcgmon
2 Enter the following command to remove the /var/lock/subsys/pcgmon file.
[admin@pcgtest ~]$ sudo rm /var/lock/subsys/pcgmon
3 When prompted to remove the file, enter y .
4 Repeat Step 1 to start the pcgmon service.
5 Enter the following command to verify that the pcgmon service is now running.
[admin@pcgtest ~]$ sudo systemctl status pcgmon
63
G
Appx auto letter
Appendix G
Reset the Password for the admin User
This appendix provides the procedure to change the password for the admin user in the event the password is lost, forgotten or expired.
In This Appendix
Resetting the Password for the admin User ...................................... 66
65
Appendix G
Reset the Password for the admin User
Resetting the Password for the admin User
Complete the following procedure to reset the password for the admin user.
Note : This procedure is written using the vSphere 6.0 Web UI. If you are using a different version or if you are using a vSphere client, the steps may differ.
1 From a Web browser, log into the vSphere 6.0 Web UI.
2 Select the VM in which the admin password needs reset.
3 From the right section of the window, click the Summary tab.
4 Click the Launch Remote Console link. The VMware Remote Console window opens for the VM opens in a new window.
Important : If you have not yet downloaded the Remote Console, click the
Download Remote Console link in the Summary window. Follow the prompts to install the remote console. Then click Launch Remote Console .
5 Select VMRC > Ctrl+Alt+Del to reboot the VM.
6 Use your arrow keys to select the appropriate boot entry from the Grub menu and then press e to edit the entry.
Note : In most cases, the first entry is the appropriate entry; therefore, you can simply enter e to edit the entry.
66
Resetting the Password for the admin User
7 Use your down arrow key to move to the linux16 line and delete the following text. console=ttypsS0,115200n8
8 Move to the end of this line and add the following text. rd.break
9 Press Ctrl+x to resume the boot process of the VM. The system boots to the bash prompt.
Note : The modifications that were made are only temporary and will not be saved.
10 At the prompt, type the following command and press Enter to mount the root file system with read/write access. switch_root:/# mount -o remount,rw /sysroot
11 At the prompt, type the following command and press Enter . switch_root:/# chroot /sysroot
67
Appendix G
Reset the Password for the admin User
12 Enter the following command to change the password for the admin user. sh-4.2# passwd admin
13 When prompted, enter the new password for the admin user and then press
Enter .
14 When prompted to retype the password, re-enter the new password and then press Enter . The output should resemble the following:
15 At the prompt, enter the following command and press Enter . sh-4.2# touch /.autorelabel
16 At the prompt, type exit and press Enter . sh-4.2# exit
17 At the prompt, type exit again and press Enter . The boot process is resumed on the VM.
18 As admin user, login with your new password.
68
Index
A
Abbreviated Procedure • 16 admin Password, Reset • 66
B
Backing Up Keyfiles • 46
Backup PCG Key files • 46
Boot Issues, Troubleshoot • 62
C
Changing the SNMPv3 User Options • 33
Chassis Front View • 36
Chassis Rear View • 37
Cisco UCS C220 Server CIMC Configuration •
38
Cisco UCS C220 Server Diagram • 36
Configure
CIMC • 38
PCG Network • 11
RAID for C220 M3 Servers • 40
RAID for C220 M4 Servers • 42
SNMPv2 • 32
SNMPv3 • 33
Configure SNMPv2 • 31
Configuring RAID for UCS C220 M3 Servers •
40
Configuring RAID for UCS C220 M4 Servers •
42
Configuring SNMPv2 • 32
Configuring SNMPv3 • 33
Configuring the PCG Network • 11
Creating the SNMPv3 User • 33
D
Defining the SNMPv3 Trap Destination • 34
Delivering ECMs • 58
Deploy the PCG Virtual Machine • 7
Deploying the PCG Virtual Machine from the vSphere Web UI • 8
Detailed View of PCI Ports • 37
E
ECMs, Deliver to DHCTs • 58
H
Hardware Requirements • 2
I
Install the Software on the EC/DTACS Server •
5 installation
Initial Login • 10
PCG Package on the EC/DTACS • 6
Installing the PCG Package on the EC or
DTACS Server • 6
Installing VMware Tools (Optional) • 16
K
Keyfiles
Backup PCG • 46
Restore PCG • 47
M
Manually Configuring the PCG Network • 54
P password reset admin • 66
PCG
Deploy Virtual Machine • 8
Package Versions • 27
Provision on DTACS • 22
Provision on EC • 18 pcgmon Service, Troubleshoot • 63
Power On and Login to the New PCG Virtual
Machine • 10
Provision the PCG on the EC/DTACS Web UI •
17
Provisioning the PCG on the DTACS Web UI •
22
Provisioning the PCG on the EC Web UI • 18
69
Index
R
RAID Configuration • 40
Reconfiguring the PCG Virtual Hardware • 9
Removing the pcgmon Lock File • 63
Resetting the Password for the admin User • 66
Restart the SNMP Service • 34
Restore PCG Keyfiles • 47
Restoring Keyfiles to a Recovered System • 47
S
SNMP, Configure • 31
SNMPv3 User, Configure • 33
Software Requirements • 3
System Requirements • 1
T
Time Zone, Update • 14
Troubleshooting Boot Issues • 62
U
UCS C220 Servers • 36
Updating the Time Zone • 14
Upgrading the PCG Package on the EC/DTACS
System • 50
Upgrading the PCG Package on the PCG Server
• 51
V
Verify PCG Versions • 27
Verifying PCG Package Versions on the
EC/DTACS • 28
Verifying the PCG Version on the PCG Server •
29
VMware Tools, Install • 16
70
Americas Headquarters http://www.cisco.com
Cisco Systems, Inc.
170 West Tasman Drive
San Jose, CA 95134-1706
USA
Tel: 408 526-4000
800 553-6387
Fax: 408 527-0883
This document includes various trademarks of Cisco Systems, Inc. Please see the Notices section of this document for a list of the Cisco Systems, Inc., trademarks used in this document.
Product and service availability are subject to change without notice.
© 2019 Cisco and/or its affiliates. All rights reserved.
January 2019
Download