American Time AllSync IQ Master Clock Installation manual
Add to My manuals2 Pages
American Time AllSync IQ is a versatile clock system designed to provide precise timekeeping and synchronization for a wide range of applications. With its advanced features and flexible configuration options, the AllSync IQ can meet the needs of businesses, schools, hospitals, and other organizations that rely on accurate timekeeping.
Key capabilities of the AllSync IQ include:
- Network connectivity: The AllSync IQ can be connected to a network via Ethernet, allowing for remote management and synchronization with other devices on the network.
- Multiple time sources: The AllSync IQ can receive time from multiple sources, including GPS, NTP servers, and manual entry, ensuring that the time displayed is always accurate and reliable.
advertisement
![American Time AllSync IQ Master Clock Installation manual | Manualzz American Time AllSync IQ Master Clock Installation manual | Manualzz](http://s3.manualzz.com/store/data/059712512_1-363d39b64b9939acbd0195436dd53ebd-360x466.png)
1
QUICK START INSTALLATION GUIDE
Choose location and install AllSync IQ Master
a. Place the AllSync IQ indoors in an area with a network drop, or run an Ethernet data cable to the unit from a network switch or hub.
b. Locate near 120vac power c. Locate near signaling and/or clock wiring
2
Mount the AllSync IQ Master
a. Wall Mount - see mounting template on reverse side
1. Use included mounting template to mark hole locations
2. Drill pilot or anchor holes
3. Install keyhole screw (leave screw head 0.1” away from wall)
4. Hang AllSync IQ master
5. Install bottom screws through open wiring compartment b. Rack Mount - install into 19” server rack (H002944 bracket kit required)
1. Place four (4) screws (not included) into server rack with H002944 kit
2. Follow instruction sheet 1719 (included wtih H002944 kit) to mount to din rail bracket
1:49
FRI OCT 3 2014
:45
AM
American Time
800-328-8996
3
Connect cables to the AllSync IQ Master
a. Connect Ethernet patch cable to Ethernet RJ45 port located on left side of AllSync IQ master.
Note: Disconnect and lockout power prior to making power connections.
b. Knock out desired power entry location.
c. Connect power wires to screw terminals labeled H (Hot), N (Neutral) and (ground) through open knockout location. Use only approved cables, strain relieve and conduit.
d. Turn on power at power source.
e. Turn on power with power switch located on left side of AllSync IQ master.
1:49
FRI OCT 3 2014
:45
AM
American Time
800-328-8996
H N
C
NO COM
CLOCK 1
NC NO COM NC
CLOCK 2
NO COM
BELL 1
NO COM
BELL 2
NO
BELL 3
COM NO COM
BELL 4
NO COM
BELL 5
NO COM
BELL 6 e
ALLSYNC IQ MASTER CLOCK
4
Use the Setup Wizard
a. PRESS 1 to start the Setup Wizard (Page 6 in Installation Manual).
b. Create a 4 digit User Lock or enter 0000 to disable this feature. PRESS O . c. Create a 4 digit Service Lock (for advanced features) or enter 0000 to disable this feature. PRESS O .
d. Select local time zone by using the <> keys. PRESS O .
e. PRESS 8 to select automatic DST (Daylight Saving Time) or 0 to disable
DST if your location doesn’t observe DST. PRESS O .
f. PRESS 1 for 12-hour mode - AM/PM (1:00PM).
PRESS 2 for 24-hour mode - Military (13:00).
g. PRESS 1 to Enable DHCP or Press 2 to Disable DHCP. PRESS O .
h. Use the keypad to enter the Unit IP Address. PRESS O .
i. Use the keypad to enter the Subnet Mask. PRESS O .
j. Use the keypad to enter the Gateway IP. PRESS O .
k. Use the keypad to enter the DNS IP. PRESS O .
l. PRESS 1 to use a Manual IP, or PRESS 2 for a DNS IP Time Server. PRESS O .
• If 1 Manual IP, use keypad to enter Time Server Address and PRESS O to accept.
Repeat for Alternative Time Server.
Skip if
1
in step g.
is selected
• If 2 DNS IP, PRESS O. Note, this value can only be changed in Remote Connect.
m. Use the keypad to enter the Time Server Address. PRESS O .
n. Use the keypad to enter the Alternate Time Server Address. PRESS O .
o. PRESS O to accept the default (80) Port Number.
p. To confirm proper set, PRESS 8 to sync.
• If successful, “Ethernet Sync Successful” will display.
• If not successful, “Ethernet Sync Failed” will display. Refer to the troubleshooting guide in the
Installation Manual.
q. “Setup Wizard Successfully Completed” will display.
5
Select Clock Code
a. Reference Appendix H in the manual for clock codes and wiring information. Clock Code 01 is set from the factory. If
01 is the code required, skip to 6 – AllSync IQ Terminal Block. If the code needs to be changed continue to next step.
b. PRESS P6 and enter your service lock to access the Configuration Menu. From the Config Menu,
PRESS 3 . This feature is used to set the clock code for wired clock circuits. Enter the clock code using the keypad, or choose 00 if you want to disable the clock code feature. Press O .
6
AllSync IQ Terminal Block
For wiring your AllSync IQ, reference your AllSync IQ Installation and Operation Manual.
Your AllSync IQ is now set up for proper operation. For information on other features, see the AllSync IQ Installation and
Operation Manual that was included with your unit. If you have any questions or problems that cannot be resolved by following the steps in the Troubleshooting guide, please contact Technical Support at American Time at 800-328-8996.
phone:
800-328-8996
online:
american-time.com
fax:
800-789-1882
10
1
/
16
8 9 /
16
INST-ASIQ Rev 2