Extron AXI 016 Setup Guide
Extron Electronics AXI 016 is a pure breakout device that provides 16 line-level outputs for EXP-enabled devices. It's simple to use and has no DSP processing hardware controls.
Advertisement
Advertisement
AXI 016 • Setup Guide
IMPO
RTAN
T: for the
Go to www complete user guide instructions,
and specifications.
This guide provides basic instructions for an experienced technician to install the AXI 016 Audio Expansion Interface. The AXI 016 is a pure breakout device that provides 16 line-level outputs for EXP-enabled devices. The AXI 016 is simple to use with no DSP processing hardware controls. For additional information and specifications, go to www.extron.com
.
NOTES:
• EXP-enabled devices are devices that contain an Extron EXP port for routing 16 bidirectional channels of digital audio.
• In this guide, “EXP-enabled devices” and “EXP devices” are used interchangeably.
6
OUTPUTS
7 8 9 10 11 12
EXP
CLIP
1 2 3 4 5 13 14 15 16
AXI 016
AUDIO EXPANSION INTERFACE
Disconnect power from the AXI 016 and power off all devices that will be connected to it. The AXI 016 is housed in a half-rack width, 6-inch deep, 1U-high metal enclosure that can be rack mounted, set on a rack shelf, or placed on a table with the provided rubber feet. Select a suitable mounting location, then choose an appropriate mounting option.
Rear Panel Connections
POWER
12V
0.7 A MAX
1
9
2
10
3 4 5
13
6
14
7 8
PRIMARY
DEVICE
SECONDARY
DEVICE
AXI 016
A Power Inlet
B
11 12 15 16
C
D
A B
Figure 1. AXI 016 Rear Panel Connections
C D
A 12 VDC Power Inlet — Connect the 12 VDC power supply to the rear panel captive screw power inlet. Then, plug the power cable into the IEC inlet on the external power supply (see figure 2 and the following Attention notices).
Rear Panel
Power Receptacle
DC Power Cord
Captive Screw
Connector
Ridged
– Return
+12 VDC input
Smooth Ground all devices.
External
Power Supply
12 VDC, 1.5 A max.
Figure 2. Connecting the External Power Supply
ATTENTION:
• Always use a power supply provided by or specified by Extron. Use of an unauthorized power supply voids all regulatory compliance certification and may cause damage to the supply and the end product.
• Utilisez toujours une source d’alimentation fournie par Extron. L’utilisation d’une source d’alimentation non autorisée annule toute conformité réglementaire et peut endommager la source d’alimentation ainsi que l’unité.
1
ATTENTION:
• If not provided with a power supply, this product is intended to be supplied by a UL Listed power source marked “Class
2” or “LPS” and rated output 12VDC, 0.4 A minimum, 48 or 56 VDC (PoE), minimum 0.35 A.
• Si ce produit n’est pas fourni avec une alimentation, il doit être utilisé avec une source d’alimentation certifiée
UL de classe 2 ou LPS avec une tension nominale 12 Vcc, 0,4 A minimum (PoE), 48 Vcc (PoE), or 56 Vcc (PoE)
0,35 A minimum.
• Unless otherwise stated, the AC/DC adapters are not suitable for use in air handling spaces or in wall cavities. The power supply is to be located within the same vicinity as the Extron AV processing equipment in an ordinary location,
Pollution Degree 2, secured to the equipment rack within the dedicated closet, podium, or desk.
• Sauf mention contraire, les adaptateurs AC/DC ne sont pas appropriés pour une utilisation dans les espaces d’aération ou dans les cavités murales. La source d’alimentation doit être située à proximité de l’équipement de traitement audiovisuel dans un endroit ordinaire, avec un degré 2 de pollution, fixé à un équipement de rack à l’intérieur d’un placard, d’une estrade, ou d’un bureau.
• The installation must always be in accordance with the applicable provisions of National Electrical Code ANSI/NFPA 70, article 725 and the Canadian Electrical Code part 1, section 16. The power supply shall not be permanently fixed to building structure or similar structure.
• Cette installation doit toujours être en accord avec les mesures qui s’applique au National Electrical Code
ANSI/NFPA 70, article 725, et au Canadian Electrical Code, partie 1, section 16. La source d’alimentation ne devra pas
être fixée de façon permanente à une structure de bâtiment ou à une structure similaire.
Analog Audio Outputs — Use 6-pole, 3.5 mm captive screw connectors to connect up to 16 balanced or unbalanced line-level devices. Balanced or unbalanced mono devices can also be connected using 3-pole, 3.5 mm captive screw connectors.
Tip
Ring
Sleeve
Tip
Ring
Sleeve
Tip
NO Ground Here
Sleeve
Tip
NO Ground Here
Sleeve
Balanced Output Unbalanced Output
6-pole Audio OUTPUT Wiring
Figure 3. Audio Output Wiring
Tip
Ring
Sleeve
Tip
NO Ground Here
Sleeve
Balanced Output Unbalanced Output
3-pole Audio OUTPUT Wiring
ATTENTION :
• For unbalanced audio outputs, connect the sleeves to the ground contact. DO NOT connect the sleeves to the negative (-) contacts.
• Pour l’audio asymétrique, connectez les manchons au contact au sol. NE PAS connecter les manchons aux contacts négatifs (–).
EXP Input Port and LED — This RJ-45 EXP port connects the AXI 016 to the EXP port of a primary EXP device.
The Expansion output channels of the primary EXP device are sent to the AXI 016 line outputs (see
Connecting a Primary Device to the EXP Input Port on the next page). The LED to the right of the
EXP INPUT port blinks to indicate a primary EXP device is connected.
NOTE: A primary EXP device is a device that has been set as a Primary Unit in DSP Configurator (see the
DMP 128 Plus User Guide for more information regarding primary and secondary EXP devices). DMP 128 Plus units are set to primary by default.
EXP Thru Port and LED — This RJ-45 EXP port connects the Expansion output channels of a secondary EXP device to the AXI 016. When a primary EXP device is connected to the EXP INPUT port, the Expansion output channels of the secondary EXP device connected to the EXP THRU port are sent through the AXI 016 to the Expansion input channels of the primary device connected to the EXP INPUT port (see
Connecting a Primary EXP Device and
Secondary EXP Device on page 4). If no primary EXP device is connected to the
EXP INPUT port, the Expansion output channels of the secondary EXP device connected to the EXP THRU port are sent to the AXI 016 line outputs
(see
Connecting a Secondary EXP Device to the EXP Thru Port on page 6). The LED to the right of the
EXP
THRU port lights solid to indicate a secondary EXP device is connected.
2
3
AXI 016 • Setup Guide (Continued)
NOTE: A secondary EXP device is a device that has been set as a Secondary Unit in DSP Configurator (see the
DMP 128 Plus User Guide for more information regarding primary and secondary EXP devices). DTP CrossPoint units are set to secondary by default.
Front Panel Features
EXP
INPUT THRU
CLIP
SIGNAL
1 2 3 4 5 6
OUTPUTS
7 8 9 10 11 12 13 14 15 16
AXI 016
AUDIO EXPANSION INTERFACE
A Power Indicator LED
B
C
EXP Indicator LEDs
Output Signal and Clip LEDs
A B C
Figure 4. AXI 016 Front Panel Features
A Power Indicator LED — This green LED lights solid when the AXI 016 is powered and fully operational.
B EXP Indicator LEDs — The green Input LED blinks to indicate a primary EXP device is connected to the rear-panel
EXP INPUT
1 2 3 4 5 6 7 8
PRIMARY
DEVICE
SECONDARY
DEVICE
AXI 016
port. The green Thru LED lights solid to indicate a secondary EXP device is connected to the rear-panel
POWER
12V
EXP THRU
0.7 A MAX
port.
9 10 11 12 13 14 15 16
C Output Signal and Clip LEDs — Sixteen pairs of stacked green and red LEDs light steadily when signal is present and increase in intensity from -60 dBFS (lowest intensity, signal presence indication) to -3 dBFS (full brightness). The red clip LEDs light solid to indicate clipping when a signal exceeds -3 dBFS. The red clip LEDs stay lit for one second after clipping ceases.
B C D
Application and Signal Flow Diagrams
The following diagrams display the different signal flows when primary and secondary EXP-enabled devices are connected to the
AXI 016.
NOTE: Daisy-chaining two or more AXI 016 units together is not supported.
Connecting a Primary Device to the EXP Input Port
The diagram below displays the AXI 016 signal flow when only a primary EXP device, such as the DMP 128 Plus, is connected to the EXP INPUT port of the AXI 016.
• All 16 Expansion output channels of the primary device are routed to the line outputs of the AXI 016 (see path A1 in figure 5).
• Expansion output channel 1 of the primary device is routed to the AXI 016 line output 1, and so on.
4 5 6 7
G O1 O2 IN G O1 O2 IN G O1 O2 IN G O1 O2 IN
4 5 6 7
9 10
11 12
DMP 128 Plus (Primary Device)
1 2 3 4
DMP 128 Plus C
5 6 7 8
+V +S -S G
A1
AXI 016
POWER
12V
0.7 A MAX
1 2 3 4 5 6 7 8
9 10 11 12 13 14 15 16
PRIMARY
DEVICE
SECONDARY
DEVICE
AXI 016
LAN
A1
NOTE: Dotted lines represent signal flows inside the AXI 016. Solid lines represent signal flows over CAT 6 cable.
Figure 5. Basic Signal Flow from Primary EXP Device to AXI 016
Connecting a Primary EXP Device and Secondary EXP Device
The diagram below displays the signal flow when a primary EXP-enabled device is connected to the EXP INPUT port and a secondary EXP-enabled device is connected to the EXP THRU port.
• All 16 Expansion output channels of the secondary device are routed through the AXI 016 and into the primary EXP device
Expansion input channels (see path B in the figure below).
• All 16 Expansion output channels of the primary EXP device are routed to the 16 analog line outputs of the AXI 016 (see path
A1 in the figure below). Expansion output channel 1 of the primary EXP device is routed to the AXI 016 line output 1, and so on.
• All 16 Expansion output channels of the primary EXP device are also routed to the Expansion input channels of the secondary EXP device (see path A2 in the figure below). Expansion output channel 1 of the secondary EXP device is routed to Expansion input channel 1 of the primary EXP device, and so on.
4
5
AXI 016 • Setup Guide (Continued)
4 5 6 7
G O1 O2 IN G O1 O2 IN G O1 O2 IN G O1 O2 IN
4 5 6 7
9 10
11 12
DMP 128 Plus (Primary Device)
1 2 3 4
DMP 128 Plus C
5 6 7 8
+V +S -S G LAN
A1 B
AXI 016
POWER
12V
0.7 A MAX
1 2 3 4 5 6 7 8
9 10 11 12 13 14 15 16
PRIMARY
DEVICE
SECONDARY
DEVICE
AXI 016
P CROSSPOINT 108 4K
100-240V ~
--A MAX
50-60 Hz
A1
B
A2
A2 B
DTP CrossPoint 108 4K (Secondary Device)
COM 1 COM 2 COM 3 DIGITAL I/O
R
Tx Rx G RTS CTS Tx Rx G Tx Rx G
IR/SERIAL
1 2 1 2
RELAYS
C 3 4 C
1 2 3 4 G
+V +S eBUS
-S G
S G S G PWR OUT = 6W
2 3 4
LAN 1
5A
LAN 2
6A
LAN 3
HDBT
XTP
5B
SIG LINK
DTP OUT
EXP
RS-232 IR
L
1
L
2
Tx Rx G Tx Rx
OVER TP
RS-232 IR
Tx Rx G Tx Rx
2 3 4 5 6 7
XTP
DTP
IN
3
4
R
R
L
5
L
6
6B
XTP
DTP
H
RS-232 IR
Tx Rx G Tx Rx
OVER TP
RS-232 IR
Tx Rx G Tx Rx
NOTE: Dotted lines represent signal flows inside the AXI 016. Solid lines represent signal flows over CAT 6 cable.
Figure 6. Advanced Signal Flow when Primary and Secondary EXP Devices are Connected
Connecting a Secondary EXP Device to the EXP Thru Port
The diagram below displays the signal flow when only a secondary EXP device such as the DTP CrossPoint 108 4K is connected to the EXP THRU port.
• All 16 Expansion output channels of the secondary EXP device are routed to the 16 line outputs of the AXI 016. The
Expansion output channels of a secondary EXP device are only routed to the AXI 016 line outputs when no primary device is connected to the EXP INPUT
previous page).
Connecting a Primary EXP Device and Secondary EXP Device on the
• Expansion output channel 1 of the secondary EXP device is routed to the AXI 016 line output 1, and so on.
AXI 016
1 2 3 4 5 6 7 8
PRIMARY
DEVICE
SECONDARY
DEVICE
AXI 016
POWER
12V
0.7 A MAX 9 10 11 12 13 14 15 16
P CROSSPOINT 108 4K
100-240V ~
--A MAX
50-60 Hz
B
DTP CrossPoint 108 4K (Secondary Device)
COM 1 COM 2 COM 3 DIGITAL I/O
R
Tx Rx G RTS CTS Tx Rx G Tx Rx G
IR/SERIAL
1 2 1 2
RELAYS
C 3 4 C
1 2 3 4 G
+V +S eBUS
-S G
S G S G PWR OUT = 6W
2 3 4
LAN 1
5A
LAN 2 LAN 3
6A
XTP
HDBT
DTP
5B
SIG LINK
OUT
EXP
RS-232 IR
L
1
L
2
Tx Rx G Tx Rx
OVER TP
RS-232 IR
Tx Rx G Tx Rx
B
2 3 4 5 6 7
XTP
DTP
IN
3
4
R
R
L
5
L
6
6B
XTP
DTP
H
RS-232 IR
Tx Rx G Tx Rx
OVER TP
RS-232 IR
Tx Rx G Tx Rx
NOTE: Dotted lines represent signal flows inside the AXI 016. Solid lines represent signal flows over CAT 6 cable.
Figure 7. Basic Signal Flow from Secondary EXP Device to AXI 016
For information on safety guidelines, regulatory compliances, EMI/EMF compatibility, accessibility, and related topics, see the
Extron Safety and Regulatory Compliance Guide on the Extron website.
© 2017-2021 Extron — All rights reserved. www.extron.com
All trademarks mentioned are the property of their respective owners.
Worldwide Headquarters: Extron USA West, 1025 E. Ball Road, Anaheim, CA 92805, 800.633.9876
68-3069-50 Rev. B
07/21
Download
Advertisement
Key features
Provides 16 line-level outputs for EXP-enabled devices.
Supports both balanced and unbalanced audio signals.
Features front panel LEDs for power, EXP connection, and signal/clip status.
Daisy-chaining of multiple AXI 016 units is not supported.
Comes with a 12 VDC power supply.
Compatible with Extron DMP 128 Plus and other EXP-enabled devices.
Frequently asked questions
The AXI 016 is a half-rack width, 1U-high metal enclosure that is 6 inches deep.
Yes, the AXI 016 supports both balanced and unbalanced audio signals.
The maximum power consumption of the AXI 016 is 0.7A.
No, daisy-chaining of multiple AXI 016 units is not supported.