Installation and operating manual

Barrier PASS 838

Important warning and safety notes for installation and operation

• These installation- and operating instructions form an integral part of this product. They have been specifically written for professional installers trained and skilled in the trade and should be carefully read in their full length before carrying out the installation. It concerns the control only, not of the overall device

“automatic gate”. After the installation this manual has to be handed over to the user.

• Installation, connection, adjustments, putting into operation, and servicing may only be carried out by trained professionals in full accordance with these installation- and operating instructions.

• The EU Machine Directive, laws and rules concerning the prevention of accidents, and laws and standards which are in force in the EU and in the individual countries have to be strictly followed.

• The TOUSEK Ges.m.b.H. cannot be held liable for any claims resulting from disregards of the laws and standards in force during the installation and operation.

• The product may only be used in accordance with its original purpose, for which it has been exclusively designed, and which is described in these installation and operating instructions. The TOUSEK Ges.m.b.H. rejects any liability if the product is used in any way not fully conforming to its original purpose as stated herein.

• The product is not suitable for installation in explosion-hazardous areas. The existance of inflammable gas and steam is of great danger !

• The packaging materials (cardboard, plastic, EPS foam parts and filling material...) have to be properly disposed of in accordance with the applying recycling- and environmental procection laws. They may be hazardous to children and therefore have to be stored out of children´s reach.

• Before beginning with the installation the installer has to make sure that all mechanical components of the gate facility, like carrier profile/rail, gate frame and panels, guiding elements etc. are sufficiently supportive and resistant for the purpose of gate automation. Check also whether the product has transport damages.

• All electrical installations have to be made in full conformity with the applying rules and laws (e.g. using a fault current circuit breaker, proper grounding...).

• An all-pole disconnecting main switch with a contact opening-gap of minimum 3 mm has to be foreseen.

• When installing the safety device (photocells, safety edges, emergency-stops etc.) please comply with the valid direcitves/standards, the criteria of practical rules of conduct, the installation environment, the operating logic of the system and the effected force of the motorised gate.

• The safety devices must secure possible bruise, shear and general danger areas of the motorised gate.

• After installation the proper function of the gate facility and the safety devices has to be checked.

• Place warning signs and notes of the valid regulations to indicate danger areas

• With each installation the identification data of the motorised gate has to be placed in a visible place.

• The electric motor heats up during operation. Therefore the device should only be touched after it has cooled off.

• Children have to be instructed, that the gate facility as well as the belonging parts may not be used improperly, e.g. for playing. Furthermore handheld transmitters have to be kept in safe places and other impulse emitters as buttons and switches have to be installed out of children‘s reach.

• Only original spare- and replacement parts may be used for repair of the product.

• The TOUSEK Ges.m.b.H. rejects any liability for claims resulting from usage of the product in combination with components or devices which do not fully conform to the applying safety laws and rules.

• The installer has to inform the user about all aspects of the automatic operation of the complete gate facility, as well as about emergency operation. The installer further has to supply to the user all instructions relating to the safe operation of the gate facility. The installation and operating instructions also have to be handed over to the user.

• The user has to be informed that he has to turn off the main power switch in case of malfunction of the product and that he can use the facility again after repair and adjustment works have been completed.

• Please notice that the warranty will not be applicable if the label with the engine number has been removed or damaged.

Maintenance

• Maintenance works have to be carried out according to our maintenance plan (page12).

This manual is the sole property of the TOUSEK Ges.m.b.H. and may not be made available to competitors. All rights reserved. No part of it may be reproduced without our prior written permission. We will not accept liability for any claims resulting from misprints or errors. This edition of the manual replaces all earlier publications of the same.

- 2 - tousek / E_PASS-838_02 / 22. 10. 2018

1. General

Characterstics

• electromechanical barrier operator for barrier width 3m to 6m

• for 230 V a.c. power supply

• suitable for continuous operation (100% duty cycle)

• emergency release mechanism

• sinusoidal motion

• technology without limit switches

• speed sensor

• red finished (RAL3000) sheet steel housing optional in INOX

• integrated control board ST 80 with clear text menu through large, illuminated LCD screen

• adjustable soft stop

• ARS Automatic Reversal System

• integrated safety edge resistance evaluator 8,2 kΩ for lower boom edge

• output for boom magnetic clamp and boom lamp with free definable light/blinking function

PASS 838 L6

Barrier PASS 838

General features

The barrier operators work electro-mechanically and are available with aluminium barrier booms (length of 3–6m depending on type). The barrier booms are painted white and have red reflective stickers. The drive unit basically consists of a mechanical gearing combined with a 230V electric motor, a balancing spring and a speed sensor.

All components are built into a robust red finished (on request also silver finished resp. in INOX ), lockable steel housing.

In case of a power failure the barrier boom can be opened and closed manually after loosening the emergency release hand wheel. Due to its particularly massive execution and the very short opening and closing times, the Tousek PASS 838 barrier operator has been designed to handle a large number of opening/closing cycles per day.

Optional accessories: base plate for barrier operator, (barrier boom) tip rest, base plate for (barrier boom) tip rest., pluggable radio receiver (tousek STN), pluggable induction loop detector (ISD 6) and barrier boom grid.

Technical Data

Barrier PASSmax. barrier width

Opening-, closing time

Motor power supply

Power consumption

Duty cycle (mode S1)

Max. cycles/day

Ambient temperature

Condenser

Boom configuration

Integrated control ST 80

Art.No.

838V-ST

1,5s

2000

3m

838 L3-ST80

230Va.c.

400W

100%

838 L4-ST80

4,5m

7s

1000

-20°C to +40°C

14µF flat (H x B) 116mm (with rubber profile) x 30mm

ST 80V ST 80 ST 80

11530360 11530330 11530340

838 L6-ST80

6m

500 round Ø 85mm

ST 80

11530350 possible equipment:

Boom

LED boom lamp

Pendulum arm or tip rest

Barrier boom grid

Other only tip rest all barrier operators PASS 838 are equipped with an emergency operation hand wheel

Housing colour: red

Note: The mentioned values „max. cycles per day“ require regular maintenance work according to our specifications (depending on intensity of operation between 1 and 4 times per year)

The barrier PASS 838V-ST is only for vehicle traffic !

tousek / E_PASS-838_02 / 22. 10. 2018 - 3 -

2. Technical layout

(1) housing door

(2) gearing lever

(3) chain

(4) gearing lever

(5) balancing spring

(6) euro standard lock cylinder

(7) earthing bolt

(8) activator bolt for door switch

(9) door safety switch

(10) drive shaft

(11) Limit bolt „boom OPEN“

(12) Limit bolt „boom CLOSED“

(13) emergency release

(14) reduction gearing

(15) drive motor

(16) electronic control with LC-Display menu

programming (16a)

1

2

3

4

5

2

6

16a

Barrier PASS 838

8

9

10

13

14

11

12

15

16

- 4 -

Barrier in position „CLOSED“

7

Barrier in position „OPEN“ tousek / E_PASS-838_02 / 22. 10. 2018

3. Installation

3a. Mounting of base plate and barrier operator

• Lead the insulating sleeves (S) for power supply and accessories into the opening of the base plate.

• Embed the base plate firmly and horizontally in the founda tion (F) (see „examples - Barrier installations“ page 13).

• Set the operator housing on the base plate with the door

(T) aligned to the road (FB) and secure it with the bolts.

Therefore it has to be ensured that the connecting cables won’t be damaged.

Foundation

• The foundations to be made must be at least 100mm larger around then the foundation plates concerned.

• The foundation must be raised from the ground level to a minimum of 100mm.

• The foundation depth from ground level to should have a minimum of 800mm (frost resistant).

• The foundation always has to be adjusted to the structure of the ground.

It should consist of concrete quality C20/25 at ground class 3. The foundation has to be horizontal and free of cracks.

• When using a support fork/tip rest pay attention to the offset V, which depends on the barrier used (barrier boom):

For barriers with flat boom:

For barrier type PASS 838 L6

(= barrier with round boom):

V = 190

V = 220

290 180

180

255

290

S

100 base plate barrier operator

100

T

100

T

FB

Barrier PASS 838

FB

V

Installation

F

Ø30 base plate guide in bracket

= barrier width - 25mm

120

150

3b. Mounting the barrier boom

Important

• The barrier boom can be installed either on the left or on the right side of the operator housing.

• Please do not load additional weight (e.g. sign boards) on the barrier boom. This could result in the damage of the gearbox unit.

left barrier

T

Important -

grease the drive shaft

• put some grease onto the external drive shaft with provided grease!

(see picture))

K

FB

Installation right barrier

T

K housing backside

• In a first step knock in a metall key (K) into the nut of the gearing drive shaft on the side of the barrier where you wish to mount the boom.

• The following mounting steps differ in accordance of whether you wish to mount the round or the flat barrier boom.

tousek / E_PASS-838_02 / 22. 10. 2018 - 5 -

Fixing the flat boom (example as left barrier)

 Push the barrier boom carrier (M) onto the drive shaft (A) , so that the knocked-in metal key drives into the nut (M.N).

 Now slide the slide-in module (E) as shown into the boom so that the drillings fall in line with the boom.

 Then bolt 4 x (with discs) the boom carrier (M) with the slide-in module inside boom (E).

 Now connect the boom (B) with cylinder head bolt (M10 x 40) and disc with drive shaft (A) (close the opening of boom with plastic plug)

Attach the plastic covers onto the boom and drive shaft end.

S1

B

E

M housing backside

(example shows boom mount for left barrier)

A

S2

4 x 

View S1

(boom carrier)

M

M.N

left barrier right barrier

View S2

(Arrangement of mounting parts for left barrier)

Important

• make sure to slide the slide in module (E) for both mounting types (left/right) into the boom so that the dropping (E.S) for the cylinder head bolt turns away from barrier housing.

- 6 -

B

M.N

M E

E.S

View S1 tousek / E_PASS-838_02 / 22. 10. 2018

Attachment of round barrier boom (example as left barrier)

 Push the barrier boom carrier (M) onto the drive shaft (A) , so that the knocked-in metal key drives into the nut (M.N).

 Now slide the slide-in module (E) as shown into the boom so that the drillings fall in line with the boom.

 Then bolt 4 x (with discs) the boom carrier (M) with the slide-in module inside boom (E) .

 Now connect the boom (B) with cylinder head bolt (M10 x 40) and disc with drive shaft (A)

(close the opening of boom with plastic plugs)

Attach the plastic covers onto the boom and drive shaft end.

S1

B

E

M

 housing back side

(example shows boom mounting of a left barrier)

S2

A

View S1

(boom carrier)

M.N

M

View S2

(Arrangement of mounting parts for left barrier)

 left barrier tousek / E_PASS-838_02 / 22. 10. 2018 right barrier B

M.N

M E

- 7 -

3c. Electrical connections

Installation

Warning

• Before carrying out the electrical connections, the power supply of the gate facility must be turned off !

• The safety regulations for electric shock prevention have to be complied.

• The device should only be connected by qualified personnel

• The device should not be used in an explosive environment !

• An all-pole disconnecting mains switch with a contact opening gap of min. 3 mm has to be foreseen.

The gate facility has to be secured according to the valid safety regulations!

• IMPORTANT: The control lines (buttons, radio, photocells, etc.) have to be laid separately from the 230V lines (supply line, motors, signal lamp). and may have a max. length of 50m.

For length > 50m decoupling steps are necessary !

• Before carrying out the electrical connections, the power supply of the gate facility must be turned off !

• Connect the operator to the control unit according corresponding control manual (mind the beside installation notes).

• For the connection of diverse safety devices, transmitters and other accessories please check the corresponding manuals

(please note cable/wire plan).

Important installation notes

• Attention: The operator works with the condenser mounted on the motor. Therefore don´t connect an additional condenser to the control unit.

• The operator housing is equipped with a safety switch

(S) which stops the motor as soon as the housing lid is opened. This safety switch must be connected to the motor control unit (input for STOP switch).

3d. Adjustment of spring tension

• The adjustment of spring tension is made by turning the screw nut (M) on the spring rod.

Important

• The spring (F) has to be adjusted so that the boom can be moved easily by hand in emergency release state. (with pendulum arm and/or boom grid).

The boom should have a position of approx.

20–40°.

SI

Installation

G

3e. Force adjusment

• The force adjustment is made by the ST80 control board.

• Due to the spring balance, the operator force is measured in a way, that the barrier boom may be stopped with little effort.

• As an additional safety device we recommend the connection of a photocell.

F

M

Warning

• The safety standards and regulations regarding the force adjustment have to be in compliance with the effective rules !

- 8 - tousek / E_PASS-838_02 / 22. 10. 2018

3f. Adjusting the limits

• The barrier operator is equipped with two adjustable limit stop bolts, one for OPEN (AO) and one for CLOSED (AG) position .

• The gearing lever (G) is being defined in its turning move ment by these two limit stop bolts in the end positions open and close. The integrated speed sensor registrates when it reaches one of the limits, whereupon the control board turns off the motor.

• The switching time and also the boom limit positions can be defined by bolting in or out the limit stop bolts.

Note

• Please note that when the limit stop bolts are being adjusted (AO or AG) the limit positions are being learned in.

• Choose in control board menu of ST 80 under

„DIAGNOSIS / delete position“ the value „YES“ .

G

T

AO

Montage

AG

IMPORTANT

• The end position of the barrier must take place according to the above services mentioned above description.

• Never use a support fork or pendulum support as a limit. These serve only to discharge of the bar!

• The company Tousek Ges.m.b.H. accepts no liability for damages resulting from such a misuse!

tousek / E_PASS-838_02 / 22. 10. 2018 - 9 -

4. Emergency release of the operator at power failure

Acute risk of injury

The operator may only be emergency released if:

>>> the power supply is turned off and >>> the barrier boom is mounted

• Turn off power supply of gate facility!

PASS 838

• ATTENTION: Make sure that the barrier boom is mounted!

• If the barrier boom is removed, there is no counterweight to the spring tension.

In this case the operator may not be emergency released since this could lead to SERIOUS INJURIES !

RELEASE

• Open the housing door and slide the cover of the emergency release in direction of front part of housing.

• Insert the 10mm Allan Key and turn it 2–3 times counter clockwise. This disengages the gear lever (G) from the gearing transmission.

• The operator is now unlocked and the boom may be moved manually (slowly ! - not faster than with the operator).

LOCKING

• To restore operation of the motor pull the emergency release clockwise again firmly.

Move the boom a little so that the lever gear snaps into the gearing.

• The lever gear (G) must rest again directly on the gearing unit.

• After closing the housing door and turning on the power supply, the motorised mode can be engaged again.

Release

2–3x

+

Locking tighten

G G

5.

Attachment of warning signs

• Additionaly to the safety installations of the barrier as suggested by safety instructions in effect, some warning signs have to be installed to warn pedestrians, bicycle drivers etc. showing special attention and informing of possible danger and for guidance to an alternative route.

ATTENTION

A U T O M

A T I C B

A R R I E R

- 10 - tousek / E_PASS-838_02 / 22. 10. 2018

6. Cable plan

1 barrier operator Tousek PASS 838

2 electronic logic control with optional available radio receiver (plugable)

3 main power switch

Note: An all-pole disconnecting main switch with a contact opening-gap of minimum 3 mm has to be

foreseen

Barrier PASS 838

4 photocell (T: transmitter, R: receiver)

5 pushbutton or key-operated momentary contact switch

6 barrier housing signal lamp

7 antenna (connection to radio receiver with coaxial cable)

8 supply with fuse max. 13A

5

6

2x0,75 mm 2

8

4x0,75 mm 2 min. 3x1,5 mm 2

2

1

7

Koaxialkabel

4E

4x0,75 mm 2

3

2x0,75 mm 2

4S

The 0,75mm2 control lines are shown without ground lead. In order to facilitate connections we recommend using flexible wires and not using thicker wires for the control lines.

Note concerning cable laying

• The electric cables have to be laid in insulating sleeves which are suitable for underground usage. The insulating sleeves have to be lead into the inner of the operator housing.

• The control lines (buttons, radio, photocells, etc.) have to be laid separately from the 230V lines (supply line, motors, signal lamp). and may have a max. length of 50m.

For length > 50m decoupling steps are necessary !

• Only double-insulated cables, which are suitable for underground usage (e.g. E-YY-J) may be used.

In case that special regulations require another type of cable, cables according to these regulations have to be used.

Warning note

Please be aware that the above picture is only a symbolic sample illustration of a gate facility and may therefore not show all safety devices required for your specific application.

To achieve an optimum safety level at your gate facility, please make sure that all safety components and accessories which - according to the applying safety rules and laws - are required in your particular case (e.g. photocells, induction loops, sensing edges, signal lamps, traffic lights, mains- and emergency power off switches etc.) are properly installed, operated, and serviced.

All possible bruise, shear and general danger areas of the motorised gate have to be secured.

In this context please follow the EU Machine Directive, accident prevention rules and laws, as well as applying EU- and national standards in force at the time of installation and operation of the gate facility.

The Tousek Ges.m.b.H. cannot be held responsible for any consequences resulting from disregard of applying standards and laws during installation or operation of the gate facility..

tousek / E_PASS-838_02 / 22. 10. 2018 - 11 -

7. Maintenance plan for barrier PASS 838

Maintenance works may only be carried out by trained professionals.

ATTENTION: Before carrying out maintenance works, turn off the power supply.

According to the frequency of actuation the following works have to be carried out 1–4 times a year:

• Check the correct fixing of the barrier housing.

• Check the balancing spring, adjust if necessary.

• Grease the guiding rod of the balancing spring.

• Grease the grease nipples (N1–N4) with the grease press.

• Check and adjust the end positions opened and closed.

• Check the proper function of the emergency release.

• Check the proper function of the housing lid safety switch.

• Check the gearing on tightness.

• Check if the assembly bolts of the gearing are properly secured.

• Check barrier boom support: - proper seat of support at the main shaft

- proper seat of the 4 internal assembly bolts

• Optical inspection of ball bearings of main shaft.

• Check force adjustment of control unit.

• Check all safety devices and accessories.

• Equalising spring (W1), chain hoist device (W2) disc spring (w3) and fastening bolt M14 (W4) have to renewed every 200.000 cycles (latest every 3 years) !

W4

W3

W2

N1

N2

N3

W1

N4

- 12 - tousek / E_PASS-838_02 / 22. 10. 2018

8. Barrier installations - Examples

• Dimensions in mm

Barrier PASS 838

Single barrier with support fork and photocell pillars

Important

• The foundations to be made must be at least

100mm larger around then the foundation plates concerned.

• The foundation must be raised from the ground level to a minimum of 100mm.

• The foundation depth from ground level to should have a minimum of 800mm (frost resistant).

• The foundation always has to be adjusted to the structure of the ground.

It should consist of concrete quality C20/25 at ground class 3. The foundation has to be horizontal and free of cracks.

• When using a support fork/tip rest pay attention to the offset V, which depends on the barrier used (barrier boom):

For barriers with flat boom:

For barrier type PASS 838 L6

(= barrier with round boom):

V = 190

V = 220

6

120

150

290

255

180

100

Distance depending on road width

Foundation plate

Photocell pillar

Ø30

Foundation plate

PASS 838

Foundation plate

Photocell pillar

Ø30

120

150

6

Distance depending on road width

Foundation plate

Tip rest/support fork

Ø30

120

150

5

V

(1) Barriers PASS 838

(2) Impulse columns

(3) Photocells

(4) Induction loops

(5) Tip rests/support forks

(6) Photocell pillars

Barrier system for separate entrance / exit with impulse columns V03

210

40 80

S

Foundation plate

Impulse pillar V03

390 330

2

Ø70

100

100

F

T

FB

Foundation plate

PASS 838

5

V

120

150

Distance depending on road width

Ø30

Foundation plate

Tip rest/support fork

1

290

255

180

100

1

290

255

180

100

(F) foundation

(S) insulating sleeves

(T) housing door

(FB) road

5

2

3

4

1

4

1

3

2

5

80 40

2

Ø70

Foundation plate

PASS 838

Distance depending on road width

Foundation plate

Tip rest/support fork

Ø30

120

150

5

V

Foundation plate

Impulse column V03

210 tousek / E_PASS-838_02 / 22. 10. 2018 - 13 -

9. Dimensioned drawing

• dimensions in mm

NOTE max. barrier width boom length

Boom configuration

838V-ST

3m

838 L3-ST80 838 L4-ST80

4,5m barrier width + 220mm flat (h x w) 116mm (with rubber profile) x 30mm

Barrier PASS 838

838 L6-ST80

6m barrier width + 280mm round Ø 85mm boom length barrier width

- 14 -

280

3

30

135

290

100

180 base plate measures and technical modifications subject to change !

tousek / E_PASS-838_02 / 22. 10. 2018

A U T O M A T I S C H E T O R A N T R I E B E

®

Declaración de incorporación

In compliance with EC Machine Directive 2006/42/EC,

Annex II B for the installation of an incomplete machine.

We hereby declare that the following product, as well as its version, put by us into circulation, complies with the essential requirements of the Machinery Directive

(2006/42/EC), due to its design and type of construction.

The validity of this declaration will cease in case of any unauthorized modifications to the products.

The product: ist entwickelt, konstruiert und gefertigt in Übereinstimmung mit der: with: EG-Richtlinie Maschinen 2006/42/EG

EG-Directive Machinery 2006/42/EG

EG-Directive Low Voltage 2014/35/EU

Angewandte und herangezogene Normen und Spezifi-

Applied and used standards and specifications:

EN ISO 13849-1, PL-„c“

EN 60335-1

EN 60335-2/95

EN 61000-6-3

EN 61000-6-2

Folgende Anforderungen des Anhangs I der EG-Richlinie

Following requirements of Annex I of the EC Directive

2006/42/EC are met:

1.1.2, 1.1.3, 1.1.5, 1.2.1, 1.2.2, 1.2.3, 1.2.6, 1.3.2, 1.3.4,

1.1.2, 1.1.3, 1.1.5, 1.2.1, 1.2.2, 1.2.3, 1.2.6, 1.3.2, 1.3.4,

1.1.2, 1.1.3, 1.1.5, 1.2.1, 1.2.2, 1.2.3, 1.2.6, 1.3.2, 1.3.4,

1.3.7, 1.5.1, 1.5.4, 1.5.6, 1.5.8, 1.7

Los documentos técnicos especiales fueron preparados

Die speziellen technischen Unterlagen wurden gemäß

The relevant technical documentation is compiled in accordance with Annex VII, Part B of the EC Machinery erstellt.

Nos comprometemos a presentar a las autoridades de

Wir verpflichten uns, diese den Marktüberwachungsbehörden auf begründetes Verlangen innerhalb einer

We undertake to submit it in electronic form and within a reasonable time to the market surveillance authorities in

Für die Zusammenstellung der technischen Unterlagen ist bevollmächtigt:

TOUSEK Ges.m.b.H., A1230 Wien, Zetschegasse 1,

Österreich

La máquina incompleta no debe ser puesta en funcionamiento, si se ha constatado que la máquina en la cual

Maschine, in die die unvollständige Maschine eingebaut werden soll, den Bestimmungen der Maschinenrichlinie machine has to be inserted, complies with the the Machine

Directive 2006/42/EC.

In compliance with EC Machine Directive 2006/42/EC,

Annex II, Part 1 A.

Wenn die neben beschriebenen Torantriebe in Verbindung mit einem Tor gebracht werden entsteht im Sinne der

EC Machine Directive.

Relevant EU directives:

Productos para la Construcción de la Directiva 89/106/CEE

Directiva de Máquinas 2006/42/CE línea

Directiva de compatibilidad electromagnética 2004/108/EC

Niederspannungsrichtlinie 2006/95/EG

Por la presente declaramos que el siguiente producto designado cumple con los requisitos esenciales de las anteriores directivas de la UE, tanto en su diseño y construcción, como puestas en circulación por nosotros. modifications to the products.

stimmten Änderung der Produkte verliert diese Erklärung

Product:

Produkt:

Torbezeichnung

The incomplete machine cannot be put into service, until it is determined that the machine, into which the incomplete machine has to be inserted, complies with the the Machine máquina incompleta debe ser instalada no cumple con las disposiciones de la Directiva de Máquinas 2006/42/

Empresa de instalación

Ausführender Montagebetrieb

Address, ZIP code, Place

Dirección, código postal

Adresse, PLZ, Ort

Date/ Signature

Fecha / Firma

Datum / Unterschrift

Motor number (Type plate):

Otros componentes:

Viena, 01. 01. 2013

tousek PRODUCTS

• sliding gate operators

• cantilever systems

• swing gate operators

• garage door operators

• folding door operators

• traffic barriers

• electronic controls

• radio remote controls

• key operated switches

• access control

• safety devices

• accessories

Tousek Ges.m.b.H.

Austria

A-1230 Vienna

Zetschegasse 1

Tel. +43/ 1/ 667 36 01

Fax +43/ 1/ 667 89 23 [email protected]

Tousek GmbH Germany

D-83395 Freilassing

Traunsteiner Straße 12

Tel. +49/ 8654/ 77 66-0

Fax +49/ 8654/ 57 196 [email protected]

Tousek Benelux NV

BE-3930 Hamont - Achel

Buitenheide 2A/ 1

Tel. +32/ 11/ 91 61 60

Fax +32/ 11/ 96 87 05 [email protected]

Tousek Sp. z o.o.

Poland

PL 43-190 Mikołów (k/Katowic)

Gliwicka 67

Tel. +48/ 32/ 738 53 65

Fax +48/ 32/ 738 53 66 [email protected]

Tousek s.r.o.

Czech Republic

CZ-130 00 Praha 3

Jagellonská 9

Tel. +420/ 2/ 2209 0980

Fax +420/ 2/ 2209 0989 [email protected]

tousek

E_PASS-838_02

22. 10. 2018 your service partner:

We reserve the right to change dimensions and/or technical specifications without prior notice. Claims resulting from misprints or errors cannot be accepted.