Juniper T4000 Interface Module Hardware Guide
โฆษณา
โฆษณา
T4000 Core Router Interface Module Reference
Modified: 2018-07-08
Copyright © 2018, Juniper Networks, Inc.
Juniper Networks, Inc.
1133 Innovation Way
Sunnyvale, California 94089
USA
408-745-2000 www.juniper.net
Juniper Networks, the Juniper Networks logo, Juniper, and Junos are registered trademarks of Juniper Networks, Inc. and/or its affiliates in the United States and other countries. All other trademarks may be property of their respective owners.
Juniper Networks assumes no responsibility for any inaccuracies in this document. Juniper Networks reserves the right to change, modify, transfer, or otherwise revise this publication without notice.
T4000 Core Router Interface Module Reference
Copyright © 2018 Juniper Networks, Inc. All rights reserved.
The information in this document is current as of the date on the title page.
YEAR 2000 NOTICE
Juniper Networks hardware and software products are Year 2000 compliant. Junos OS has no known time-related limitations through the year 2038. However, the NTP application is known to have some difficulty in the year 2036.
END USER LICENSE AGREEMENT
The Juniper Networks product that is the subject of this technical documentation consists of (or is intended for use with) Juniper Networks software. Use of such software is subject to the terms and conditions of the End User License Agreement (“EULA”) posted at https://www.juniper.net/support/eula/ . By downloading, installing or using such software, you agree to the terms and conditions of that
EULA.
ii Copyright © 2018, Juniper Networks, Inc.
Table of Contents
Documentation and Release Notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xvii
Self-Help Online Tools and Resources . . . . . . . . . . . . . . . . . . . . . . . . . . . xx
Determining Transceiver Support and Specifications for M Series and T Series
10-Gigabit Ethernet DWDM OTN PIC (PC-1XGE-DWDM-OTN) Optical Interface
10-Gigabit Ethernet DWDM OTN Optical Interface Specifications . . . . . . . . . 18
10-Gigabit Ethernet DWDM OTN Supported Wavelengths . . . . . . . . . . . . . . 20
PC-1XGE-DWDM-OTN Optical Signal-to-Noise Ratio (OSNR)
10-Gigabit Ethernet DWDM Transceiver (XFP-10G-CBAND-T50-ZR)
Copyright © 2018, Juniper Networks, Inc.
iii
T4000 Core Router Interface Module Reference iv
SONET/SDH OC3/STM1 Optical Interface Specifications . . . . . . . . . . . . . . . . . . . 24
SONET/SDH OC3/STM1 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
SONET/SDH OC3/STM1 Intermediate Reach (IR-1) Specifications . . . . . . . . 24
SONET/SDH OC3/STM1 Long Reach (LR-1) Specifications . . . . . . . . . . . . . . 25
SONET/SDH OC12/STM4 Optical Interface Specifications . . . . . . . . . . . . . . . . . . 25
SONET/SDH OC12/STM4 Short Reach (SR-1) Specifications . . . . . . . . . . . . 25
SONET/SDH OC12/STM4 Intermediate Reach (IR-1) Specifications . . . . . . . 26
SONET/SDH OC12/STM4 Long Reach (LR-1) Specifications . . . . . . . . . . . . . 26
SONET/SDH OC12/STM4 Long Reach (LR-2) Specifications . . . . . . . . . . . . . 27
SONET/SDH OC48/STM16 Optical Interface Specifications . . . . . . . . . . . . . . . . . 27
SONET/SDH OC48/STM16 Short Reach (SR-1) Specifications . . . . . . . . . . . 28
SONET/SDH OC48/STM16 Intermediate Reach (IR-1) Specifications . . . . . 28
SONET/SDH OC48/STM16 Long Reach (LR-1) Specifications . . . . . . . . . . . 28
SONET/SDH OC48/STM16 Long Reach (LR-2) Specifications . . . . . . . . . . . 29
SONET/SDH OC192/STM64 Optical Interface Specifications . . . . . . . . . . . . . . . . 29
SONET/SDH OC192/STM64 Very Short Reach (VSR) . . . . . . . . . . . . . . . . . . 30
SONET/SDH OC192/STM64 Short Reach (SR-1) . . . . . . . . . . . . . . . . . . . . . . 30
SONET/SDH OC192/STM64 Short Reach (SR-2) . . . . . . . . . . . . . . . . . . . . . . 31
SONET/SDH OC192/STM64 Intermediate Reach (IR-2) . . . . . . . . . . . . . . . . . 31
SONET/SDH OC192/STM64 Long reach (LR-1) . . . . . . . . . . . . . . . . . . . . . . . 32
SONET/SDH OC192/STM64 Long reach (LR-2) . . . . . . . . . . . . . . . . . . . . . . . 32
SONET/SDH OC768/STM256 Optical Interface Specifications . . . . . . . . . . . . . . 32
Channelized Enhanced IQ (IQE) PIC Descriptions . . . . . . . . . . . . . . . . . . . . . . 51
Channelized DS3/E3 Enhanced IQ (IQE) PIC (T4000 Router) . . . . . . . . . . . . . . . 52
Channelized E1/T1 Enhanced IQ (IQE) PIC (T4000 Router) . . . . . . . . . . . . . . . . . 55
Channelized OC3/STM1 Enhanced IQ (IQE) PIC with SFP (T4000 Router) . . . . 58
Copyright © 2018, Juniper Networks, Inc.
Table of Contents
Channelized OC12/STM4 Enhanced IQ (IQE) PICs with SFP (T4000 Router) . . . 62
Channelized OC48/STM16 Enhanced IQ (IQE) PIC with SFP (T4000 Router) . . 69
PICs Supported in the Fourth Slot of T640-FPC2-E and T640-FPC2-E2 with
DS3/E3 Enhanced IQ (IQE) PIC (T4000 Router) . . . . . . . . . . . . . . . . . . . . . . . . . . 77
Gigabit Ethernet PICs with SFP (T4000 Router) . . . . . . . . . . . . . . . . . . . . . . . . . . 83
Gigabit Ethernet IQ PIC with SFP (T4000 Router) . . . . . . . . . . . . . . . . . . . . . . . . 86
Gigabit Ethernet IQ PIC with SFP LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88
Gigabit Ethernet IQ2 PICs with SFP (T4000 Router) . . . . . . . . . . . . . . . . . . . . . . 89
Gigabit Ethernet Enhanced IQ2 (IQ2E) PIC with SFP (T4000 Router) . . . . . . . . . 92
Copyright © 2018, Juniper Networks, Inc.
v
T4000 Core Router Interface Module Reference vi
10-Gigabit Ethernet PIC with XENPAK (T4000 Router) . . . . . . . . . . . . . . . . . . . . 97
10-Gigabit Ethernet IQ2 PIC with XFP (T4000 Router) . . . . . . . . . . . . . . . . . . . . 100
10-Gigabit Ethernet IQ2E PIC with XFP (T4000 Router) . . . . . . . . . . . . . . . . . . . 103
10-Gigabit Ethernet LAN/WAN PIC with SFP+ (T4000 Router) . . . . . . . . . . . . . 106
10-Gigabit Ethernet LAN/WAN PIC with Oversubscription and SFP+ (T4000
10-Gigabit Ethernet LAN/WAN PIC with XFP (T4000 Router) . . . . . . . . . . . . . . . 117
40-Gigabit Ethernet PIC with CFP (T4000 Router) . . . . . . . . . . . . . . . . . . . . . . . 121
Copyright © 2018, Juniper Networks, Inc.
Table of Contents
100-Gigabit Ethernet PIC with CFP (T4000 Router) . . . . . . . . . . . . . . . . . . . . . . 125
SONET/SDH OC3/STM1 (Multi-Rate) PICs with SFP (T4000 Router) . . . . . . . . 139
SONET/SDH OC12/STM4 (Multi-Rate) PICs with SFP (T4000 Router) . . . . . . . 144
SONET/SDH OC48c/STM16 PIC with SFP (T4000 Router) . . . . . . . . . . . . . . . . 148
SONET/SDH OC48/STM16 Enhanced IQ (IQE) PIC with SFP (T4000
Copyright © 2018, Juniper Networks, Inc.
vii
T4000 Core Router Interface Module Reference viii
SONET/SDH OC48/STM16 (Multi-Rate) PIC with SFP (T4000 Router) . . . . . . 156
SONET/SDH OC192/STM64 PICs with XFP (T4000 Router) . . . . . . . . . . . . . . . 160
SONET/SDH OC768c/STM256 PIC (T4000 Router) . . . . . . . . . . . . . . . . . . . . . . 165
10-Gigabit Ethernet DWDM OTN EOL PIC (T4000 Router) . . . . . . . . . . . . . . . . . 169
SONET/SDH OC12c/STM4 EOL PIC (T4000 Router) . . . . . . . . . . . . . . . . . . . . . . 171
SONET/SDH OC48c/STM16 EOL PICs (T4000 Router) . . . . . . . . . . . . . . . . . . . 175
SONET/SDH OC48c/STM16 EOL PIC with SFP (T4000 Router) . . . . . . . . . . . . 179
Copyright © 2018, Juniper Networks, Inc.
Table of Contents
SONET/SDH OC192/STM64 EOL PIC (T4000 Router) . . . . . . . . . . . . . . . . . . . . 182
Copyright © 2018, Juniper Networks, Inc.
ix
T4000 Core Router Interface Module Reference x Copyright © 2018, Juniper Networks, Inc.
List of Figures
Channelized Enhanced IQ (IQE) PIC Descriptions . . . . . . . . . . . . . . . . . . . . . . 51
Figure 16: SONET/SDH OC3/STM1 (Multi-Rate) PIC (Type 1) . . . . . . . . . . . . . . . 139
Figure 17: SONET/SDH OC3/STM1 (Multi-Rate) PIC (Type 2) . . . . . . . . . . . . . . . 139
Figure 18: 1-Port SONET/SDH OC12/STM4 (Multi-Rate) PIC . . . . . . . . . . . . . . . . 144
Figure 19: 4-Port SONET/SDH OC12/STM4 (Multi-Rate) PIC . . . . . . . . . . . . . . . 144
Figure 20: 1-Port SONET/SDH OC192/STM64 PIC . . . . . . . . . . . . . . . . . . . . . . . . 160
Figure 21: 4-Port SONET/SDH OC192/STM64 PIC . . . . . . . . . . . . . . . . . . . . . . . . 160
Figure 22: 4-Port SONET/SDH OC12c/STM4 PIC . . . . . . . . . . . . . . . . . . . . . . . . . . 171
Figure 23: 1-Port SONET/SDH OC48c/STM16 PIC . . . . . . . . . . . . . . . . . . . . . . . . . 175
Figure 24: 4-Port SONET/SDH OC48c/STM16 PIC . . . . . . . . . . . . . . . . . . . . . . . . 175
Copyright © 2018, Juniper Networks, Inc.
xi
T4000 Core Router Interface Module Reference xii Copyright © 2018, Juniper Networks, Inc.
List of Tables
Table 3: ATM IQ PICs Supported in the T4000 Router . . . . . . . . . . . . . . . . . . . . . . . 3
Table 4: Channelized PICs Supported in the T4000 Router . . . . . . . . . . . . . . . . . . 4
Table 5: Gigabit Ethernet PICs Supported in the T4000 Router . . . . . . . . . . . . . . . 4
Table 6: 10-Gigabit Ethernet PICs Supported in the T4000 Router . . . . . . . . . . . . 5
Table 7: 40-Gigabit Ethernet PICs Supported in the T4000 Router . . . . . . . . . . . . 5
Table 8: 100-Gigabit Ethernet PICs Supported in the T4000 Router . . . . . . . . . . . 6
Table 9: Services PICs Supported in the T4000 Router . . . . . . . . . . . . . . . . . . . . . . 6
Table 10: SONET/SDH PICs Supported in the T4000 Router . . . . . . . . . . . . . . . . . 6
Table 11: End-of-Life PICs Supported in the T4000 Router . . . . . . . . . . . . . . . . . . . 8
Table 17: 10-Gigabit Ethernet DWDM OTN Optical Interface Specifications . . . . . 18
Table 18: 10-Gigabit Ethernet DWDM OTN Supported Wavelengths . . . . . . . . . . . 21
Table 19: PC-1XGE-DWDM-OTN Optical Signal-to-Noise Ratio (OSNR)
Table 20: Programmable Wavelengths Supported by 10-Gigabit Ethernet DWDM
Table 21: SONET/SDH OC3/STM1 Multimode Optical Interface
Table 22: SONET/SDH OC3/STM1 Intermediate Reach Optical Interface
Table 23: SONET/SDH OC3/STM1 Long Reach -1 Optical Interface
Table 24: SONET/SDH OC12/STM4 Short Reach (SR-1) Optical Interface
Table 25: SONET/SDH OC12/STM4 Intermediate Reach (IR-1) Optical Interface
Table 26: SONET/SDH OC12/STM4 Long Reach (LR-1) Optical Interface
Copyright © 2018, Juniper Networks, Inc.
xiii
T4000 Core Router Interface Module Reference xiv
Table 27: SONET/SDH OC12/STM4 Long Reach (LR-2) Optical Interface
Table 28: SONET/SDH OC48/STM16 Short Reach (SR-1) Optical Interface
Table 29: SONET/SDH OC48/STM16 Intermediate Reach (IR-1) Optical Interface
Table 30: SONET/SDH OC48/STM16 Long Reach (LR-1) Optical Interface
Table 31: SONET/SDH OC48/STM16 Long Reach (LR-2) Optical Interface
Table 32: SONET/SDH OC192/STM64 Very Short Reach (VSR 1) Optical Interface
Table 33: SONET/SDH OC192/STM64 Short Reach (SR-1) Optical Interface
Table 34: SONET/SDH OC192/STM64 Short Reach (SR-2) Optical Interface
Table 35: SONET/SDH OC192/STM64 Intermediate Reach (IR-2) Optical
Table 36: SONET/SDH OC192/STM64 Long Reach (LR-1) Optical Interface
Table 37: SONET/SDH OC192/STM64 Long Reach (LR-2) Optical Interface
Table 38: SONET/SDH OC768/STM256 Short Reach (SR-1) Optical Interface
Channelized Enhanced IQ (IQE) PIC Descriptions . . . . . . . . . . . . . . . . . . . . . . 51
Table 44: Channelized OC12/STM4 Enhanced IQ (IQE) PICs with SFP LEDs . . . . 66
Table 46: Channelized OC48/STM16 Enhanced IQ (IQE) PIC with SFP LEDs . . . . 72
Table 53: Gigabit Ethernet IQ2 PICs with SFP LEDs . . . . . . . . . . . . . . . . . . . . . . . . 91
Copyright © 2018, Juniper Networks, Inc.
List of Tables
Table 55: Gigabit Ethernet Enhanced IQ2 (IQ2E) PIC with SFP LEDs . . . . . . . . . . 94
Table 57: 10-Gigabit Ethernet PIC with XENPAK LEDs . . . . . . . . . . . . . . . . . . . . . . 99
Table 59: 10-Gigabit Ethernet IQ2 PIC with XFP LEDs . . . . . . . . . . . . . . . . . . . . . 102
Table 61: 10-Gigabit Ethernet IQ2E PIC with XFP LEDs . . . . . . . . . . . . . . . . . . . . . 105
Table 63: 10-Gigabit Ethernet LAN/WAN PIC with SFP+ LEDs . . . . . . . . . . . . . . 109
Table 65: Software Features Supported on 24-Port Type 5 PIC with
Table 66: 10-Gigabit Ethernet LAN/WAN PIC with Oversubscription and SFP+
Table 68: 10-Gigabit Ethernet LAN/WAN PIC with XFP LEDs . . . . . . . . . . . . . . . . 119
Table 70: 40-Gigabit Ethernet PIC with CFP LEDs . . . . . . . . . . . . . . . . . . . . . . . . 123
Table 71: Software Features Supported on Type 5 PIC . . . . . . . . . . . . . . . . . . . . . 126
Table 72: Software Features Supported on Type 4 PIC . . . . . . . . . . . . . . . . . . . . . 128
Table 75: MultiServices PICs Software Features Supported on the T4000
Table 79: SONET/SDH OC3/STM1 (Multi-Rate) PIC with SFP LEDs . . . . . . . . . . 142
Table 81: SONET/SDH OC12/STM4 (Multi-Rate) PICs with SFP LEDs . . . . . . . . 146
Table 83: SONET/SDH OC48c/STM16 PIC with SFP LEDs . . . . . . . . . . . . . . . . . 150
Table 85: SONET/SDH OC48/STM16 Enhanced IQ (IQE) PIC with SFP LEDs . . 154
Table 87: SONET/SDH OC48/STM16 (Multi-Rate) PIC with SFP LEDs . . . . . . . . 158
Table 89: 1-Port SONET/SDH OC192/STM64 PIC LEDs . . . . . . . . . . . . . . . . . . . . 162
Table 90: 4-Port SONET/SDH OC192/STM64 PIC LEDs . . . . . . . . . . . . . . . . . . . 163
Copyright © 2018, Juniper Networks, Inc.
xv
T4000 Core Router Interface Module Reference
Table 92: SONET/SDH OC768c/STM256 PIC LEDs . . . . . . . . . . . . . . . . . . . . . . . 167
Table 94: 10-Gigabit Ethernet DWDM OTN EOL PIC LEDs . . . . . . . . . . . . . . . . . . . 171
Table 96: SONET/SDH OC12c/STM4 EOL PIC LEDs . . . . . . . . . . . . . . . . . . . . . . . 173
Table 98: SONET/SDH OC48c/STM16 EOL PICs LEDs . . . . . . . . . . . . . . . . . . . . . 177
Table 100: SONET/SDH OC48c/STM16 EOL PIC with SFP LEDs . . . . . . . . . . . . . 181
Table 102: SONET/SDH OC192/STM64 EOL PIC LEDs . . . . . . . . . . . . . . . . . . . . . 184
xvi Copyright © 2018, Juniper Networks, Inc.
About the Documentation
•
Documentation and Release Notes on page xvii
•
Documentation Conventions on page xvii
•
Documentation Feedback on page xix
•
Requesting Technical Support on page xx
Documentation and Release Notes
To obtain the most current version of all Juniper Networks
® technical documentation, see the product documentation page on the Juniper Networks website at https://www.juniper.net/documentation/ .
If the information in the latest release notes differs from the information in the documentation, follow the product Release Notes.
Juniper Networks Books publishes books by Juniper Networks engineers and subject matter experts. These books go beyond the technical documentation to explore the nuances of network architecture, deployment, and administration. The current list can be viewed at https://www.juniper.net/books .
Documentation Conventions
defines notice icons used in this guide.
Copyright © 2018, Juniper Networks, Inc.
xvii
T4000 Core Router Interface Module Reference
Table 1: Notice Icons
Icon Meaning
Informational note
Caution
Warning
Laser warning
Tip
Best practice
Description
Indicates important features or instructions.
Indicates a situation that might result in loss of data or hardware damage.
Alerts you to the risk of personal injury or death.
Alerts you to the risk of personal injury from a laser.
Indicates helpful information.
Alerts you to a recommended use or implementation.
defines the text and syntax conventions used in this guide.
Table 2: Text and Syntax Conventions
Convention Description Examples
Bold text like this
Fixed-width text like this
Represents text that you type.
Represents output that appears on the terminal screen.
To enter configuration mode, type the configure command: user@host> configure user@host> show chassis alarms
No alarms currently active
Italic text like this
Italic text like this
•
•
•
Introduces or emphasizes important new terms.
Identifies guide names.
Identifies RFC and Internet draft titles.
•
•
•
A policy term is a named structure that defines match conditions and actions.
Junos OS CLI User Guide
RFC 1997, BGP Communities Attribute
Represents variables (options for which you substitute a value) in commands or configuration statements.
Configure the machine’s domain name:
[edit] root@# set system domain-name domain-name xviii Copyright © 2018, Juniper Networks, Inc.
About the Documentation
Table 2: Text and Syntax Conventions (continued)
Convention Description
Text like this
< > (angle brackets)
| (pipe symbol)
Examples
Represents names of configuration statements, commands, files, and directories; configuration hierarchy levels; or labels on routing platform components.
•
•
To configure a stub area, include the stub statement at the [edit protocols ospf area area-id] hierarchy level.
The console port is labeled CONSOLE .
Encloses optional keywords or variables.
stub <default-metric metric >;
Indicates a choice between the mutually exclusive keywords or variables on either side of the symbol. The set of choices is often enclosed in parentheses for clarity.
broadcast | multicast
( string1 | string2 | string3 )
# (pound sign)
[ ] (square brackets)
Indention and braces ( { } )
; (semicolon)
Indicates a comment specified on the same line as the configuration statement to which it applies.
rsvp { # Required for dynamic MPLS only
Encloses a variable for which you can substitute one or more values.
Identifies a level in the configuration hierarchy.
Identifies a leaf statement at a configuration hierarchy level.
community name members [ community-ids ]
[edit] routing-options { static { route default { nexthop address; retain;
}
}
}
GUI Conventions
Bold text like this
> (bold right angle bracket)
Represents graphical user interface (GUI) items you click or select.
•
•
In the Logical Interfaces box, select
All Interfaces .
To cancel the configuration, click
Cancel .
Separates levels in a hierarchy of menu selections.
In the configuration editor hierarchy, select Protocols>Ospf .
Documentation Feedback
We encourage you to provide feedback, comments, and suggestions so that we can improve the documentation. You can provide feedback by using either of the following methods:
• Online feedback rating system—On any page of the Juniper Networks TechLibrary site at https://www.juniper.net/documentation/index.html
, simply click the stars to rate the content, and use the pop-up form to provide us with information about your experience.
Alternately, you can use the online feedback form at https://www.juniper.net/documentation/feedback/ .
Copyright © 2018, Juniper Networks, Inc.
xix
T4000 Core Router Interface Module Reference
• E-mail—Send your comments to [email protected]
. Include the document or topic name, URL or page number, and software version (if applicable).
Requesting Technical Support
Technical product support is available through the Juniper Networks Technical Assistance
Center (JTAC). If you are a customer with an active J-Care or Partner Support Service support contract, or are covered under warranty, and need post-sales technical support, you can access our tools and resources online or open a case with JTAC.
• JTAC policies—For a complete understanding of our JTAC procedures and policies, review the JTAC User Guide located at https://www.juniper.net/us/en/local/pdf/resource-guides/7100059-en.pdf
.
• Product warranties—For product warranty information, visit https://www.juniper.net/support/warranty/ .
• JTAC hours of operation—The JTAC centers have resources available 24 hours a day,
7 days a week, 365 days a year.
Self-Help Online Tools and Resources
For quick and easy problem resolution, Juniper Networks has designed an online self-service portal called the Customer Support Center (CSC) that provides you with the following features:
• Find CSC offerings: https://www.juniper.net/customers/support/
• Search for known bugs: https://prsearch.juniper.net/
• Find product documentation: https://www.juniper.net/documentation/
• Find solutions and answer questions using our Knowledge Base: https://kb.juniper.net/
• Download the latest versions of software and review release notes: https://www.juniper.net/customers/csc/software/
• Search technical bulletins for relevant hardware and software notifications: https://kb.juniper.net/InfoCenter/
• Join and participate in the Juniper Networks Community Forum: https://www.juniper.net/company/communities/
• Open a case online in the CSC Case Management tool: https://www.juniper.net/cm/
To verify service entitlement by product serial number, use our Serial Number Entitlement
(SNE) Tool: https://entitlementsearch.juniper.net/entitlementsearch/
Opening a Case with JTAC
You can open a case with JTAC on the Web or by telephone.
• Use the Case Management tool in the CSC at https://www.juniper.net/cm/ .
• Call 1-888-314-JTAC (1-888-314-5822 toll-free in the USA, Canada, and Mexico).
xx Copyright © 2018, Juniper Networks, Inc.
About the Documentation
For international or direct-dial options in countries without toll-free numbers, see https://www.juniper.net/support/requesting-support.html
.
Copyright © 2018, Juniper Networks, Inc.
xxi
T4000 Core Router Interface Module Reference xxii Copyright © 2018, Juniper Networks, Inc.
PART 1
Overview
•
T4000 Interface Modules Support on page 3
•
Network Interface Specifications on page 17
Copyright © 2018, Juniper Networks, Inc.
1
T4000 Core Router Interface Module Reference
2 Copyright © 2018, Juniper Networks, Inc.
CHAPTER 1
T4000 Interface Modules Support
•
T4000 PICs Supported on page 3
•
T4000 End-of-Life PICs Supported on page 7
•
T4000 PIC/FPC Compatibility on page 8
T4000 PICs Supported
through
list the PICs supported by the T4000 router by PIC family. The First Junos OS Release Support column indicates the first release the PIC was supported on the T4000 router.
•
•
•
Gigabit Ethernet PICs on page 4
•
10-Gigabit Ethernet PICs on page 4
•
40-Gigabit Ethernet PICs on page 5
•
100-Gigabit Ethernet PICs on page 5
•
•
ATM IQ PICs
lists the ATM IQ PICs supported by the T4000 router.
Table 3: ATM IQ PICs Supported in the T4000 Router
PIC Family and Type Ports Model Number Connectors
First Junos OS
Release
Support
2 PB-2OC12-ATM2-SMIR Optical: SC 12.2R2
Channelized PICs
lists the Channelized PICs supported by the T4000 router.
Copyright © 2018, Juniper Networks, Inc.
3
T4000 Core Router Interface Module Reference
Table 4: Channelized PICs Supported in the T4000 Router
PIC Family and Type Ports
4
4
SFP (T4000 Router)” on page 62
4
4
SFP (T4000 Router)” on page 69
1
Model Number
PB-4CHDS3-QPP
PB-4CHDS3-E3-IQE-BNC
PB-4CHOC12-STM4-IQE-SFP
PC-4CHOC12-STM4-IQE-SFP
PB-1CHOC48-STM16-IQE-SFP
Connectors
Coaxial
Coaxial
Optical: LC
Optical: LC
Optical: LC
First Junos OS
Release
Support
12.1R2
12.1.R2
12.2R1
13.2
12.2R1
Gigabit Ethernet PICs
lists the Gigabit Ethernet PICs supported by the T4000 router.
Table 5: Gigabit Ethernet PICs Supported in the T4000 Router
PIC Family and Type Ports Model Number Connectors
First Junos OS
Release
Support
PB-2GE-SFP Optical: LC 12.2R2
SFP (T4000 Router)” on page 83
2
SFP (T4000 Router)” on page 86
2
“Gigabit Ethernet IQ2 PICs with SFP (T4000 Router)” on page 89
8
8
4
10
PB-4GE-SFP
PC-10GE-SFP
PB-2GE-SFP-QPP
PC-8GE-TYPE3-SFP-IQ2
PB-8GE-TYPE2-SFP-IQ2
Optical: LC
Optical: LC
Optical: LC
Optical: LC
Optical: LC
12.2R2
12.1R2
12.2R2
12.1R2
12.2R2
8 PC-8GE-TYPE3-SFP-IQ2E Optical: LC 12.1R2
10-Gigabit Ethernet PICs
lists the 10-Gigabit Ethernet PICs supported by the T4000 router.
4 Copyright © 2018, Juniper Networks, Inc.
Chapter 1: T4000 Interface Modules Support
Table 6: 10-Gigabit Ethernet PICs Supported in the T4000 Router
PIC Family and Type
XENPAK (T4000 Router)” on page 97
1
Ports
“10-Gigabit Ethernet IQ2 PIC with XFP (T4000 Router)” on page 100
1
“10-Gigabit Ethernet IQ2E PIC with XFP (T4000 Router)” on page 103
1
12
10
24
4
Model Number
PC-1XGE-XENPAK
PC-1XGE-TYPE3-XFP-IQ2
PC-1XGE-TYPE3-XFP-IQ2E
PF-12XGE-SFPP
PD-5-10XGE-SFPP
PF-24XGE-SFPP
PD-4XGE-XFP
Connectors
Optical: SC
Optical: LC
Optical: LC
Optical: LC
Optical: LC
Optical: LC
Optical: LC
First Junos OS
Release
Support
12.2R2
12.1R2
12.1R2
12.1
12.1R2
12.2
12.1R2
40-Gigabit Ethernet PICs
lists the 40-Gigabit Ethernet PICs supported by the T4000 router.
Table 7: 40-Gigabit Ethernet PICs Supported in the T4000 Router
PIC Family and Type Ports Model Number Connectors
First Junos OS
Release
Support
CFP (T4000 Router)” on page 121
4 PD-1XLE-CFP Optical: SC 13.2
100-Gigabit Ethernet PICs
lists the 100-Gigabit Ethernet PICs supported by the T4000 router.
Copyright © 2018, Juniper Networks, Inc.
5
T4000 Core Router Interface Module Reference
Table 8: 100-Gigabit Ethernet PICs Supported in the T4000 Router
PIC Family and Type
“100-Gigabit Ethernet PIC with
CFP (T4000 Router)” on page 125
1
1
Ports Model Number
PF-1CGE-CFP
Connectors
First Junos OS
Release
Support
Optical: SC, LC, or
24-fiber MPO depending on the transceiver. See the
PIC description for more information.
12.1
PD-1CE-CFP-FPC4 (PIC and FPC)
NOTE: This PIC is available only packaged in an assembly with the
T1600-FPC4-ES FPC.
Optical: SC, LC, or
24-fiber MPO depending on the transceiver. See the
PIC description for more information.
12.1R2
Services PICs
lists the services PICs supported by the T4000 router.
Table 9: Services PICs Supported in the T4000 Router
PIC Family and Type Ports Model Number Connectors
First Junos OS
Release
Support
0
0
0
0
PB-MS-400-2
PB-MS-500-3
PC-TUNNEL
PB-TUNNEL
None
None
None
None
12.2
12.1R2
12.1R2
12.2R2
SONET/SDH PICs
lists the SONET/SDH PICs supported by the T4000 router.
Table 10: SONET/SDH PICs Supported in the T4000 Router
PIC Family and Type Ports Model Number Connectors
First Junos OS
Release
Support
PB-4OC3-1OC12-SON2-SFP Optical: LC 12.2R2
4
4 PB-4OC3-4OC12-SON-SFP Optical: LC 12.2R2
6 Copyright © 2018, Juniper Networks, Inc.
Chapter 1: T4000 Interface Modules Support
Table 10: SONET/SDH PICs Supported in the T4000 Router (continued)
PIC Family and Type Ports
PIC with SFP (T4000 Router)” on page 148
4
SFP (T4000 Router)” on page 152
1
1
4
1
4
1
Model Number
PC-4OC48-SON-SFP
PB-1OC48-SON-SMSR
PC-4OC48-STM16-IQE-SFP
PB-1OC48-SON-B-SFP
PC-1OC192-SON-XFP
PD-4OC192-SON-XFP
PD-1OC768-SON-SR
Connectors
Optical: LC
Optical: SC
Opticl: LC
Optical: LC
Optical: LC
Optical: LC
Optical: SC
First Junos OS
Release
Support
12.1R2
12.2R2
13.2
12.2R2
12.1R2
12.1
12.1
Related
Documentation
• T4000 PIC Description
•
T4000 End-of-Life PICs Supported on page 7
•
T4000 PIC/FPC Compatibility on page 8
T4000 End-of-Life PICs Supported
lists the end-of-life PICs supported by the T4000 router. The PICs are listed alphabetically by PIC family.
NOTE: End-of-life (EOL) indicates that the product has been removed from the price list and is no longer available for purchase. End-of-support (EOS) indicates that no new support contracts are available on these products and the last contract will expire on the EOS date associated with each product.
Copyright © 2018, Juniper Networks, Inc.
7
T4000 Core Router Interface Module Reference
Table 11: End-of-Life PICs Supported in the T4000 Router
PIC Family and Type
“10-Gigabit Ethernet DWDM OTN EOL PIC
1
4
Ports Model Number
PC-1XGE-DWDM-OTN
PB-4OC12-SON-MM
PB-4OC12-SON-SMIR
“SONET/SDH OC48c/STM16 EOL PICs
“SONET/SDH OC48c/STM16 EOL PIC with
SFP (T4000 Router)” on page 179
1
“SONET/SDH OC192/STM64 EOL PIC
1
4
1
PC-4OC48-SON-SMSR
PB-1OC48-SON-SMSR
PB-1OC48-SON-SFP
PC-1OC192-SON-SR2
Connectors
Optical: SC
Optical: SC
Optical: SC
Optical: SC
Optical: LC
Optical: SC
First Junos OS
Release Support
12.1R2
12.2R2
12.1R2
12.2R2
12.2R2
12.1R2
Related
Documentation
• T4000 PIC Description
•
T4000 PICs Supported on page 3
•
T4000 PIC/FPC Compatibility on page 8
T4000 PIC/FPC Compatibility
The PIC/FPC compatibility matrixes list the current PICs for the T4000 router. For example, Junos OS Release 12.1 is the first release in which the T1600-FPC4-ES supports the OC192/STM64, 4-port PIC in the T4000 router.
•
PIC/FPC Compatibility (Type 1) on page 8
•
PIC/FPC Compatibility (Type 2) on page 10
•
PIC/FPC Compatibility (Type 3) on page 11
•
PIC/FPC Compatibility (Type 4) on page 14
•
PIC/FPC Compatibility (Type 5) on page 14
PIC/FPC Compatibility (Type 1)
provides a PIC/FPC compatibility matrix for the current Type 2 PICs for the T4000 router and Type 2 FPCs.
8 Copyright © 2018, Juniper Networks, Inc.
Table 12: T4000 PIC/FPC Compatibility Type 1
Type 1 PIC PIC Model Number
Channelized IQ PICs
“Channelized DS3 IQ PIC (T4000
PB-4CHDS3-QPP
“Channelized OC3 IQ PIC (T4000
PB-1CHOC3-SMIR-QPP
“Channelized STM1 IQ PIC (T4000
PB-1CHSTM1-SMIR-QPP
Channelized IQE PICs
“Channelized DS3/E3 Enhanced IQ
(IQE) PIC (T4000 Router)” on page 52
PB-4CHDS3-E3-IQE-BNC
“Channelized E1/T1 Enhanced IQ
(IQE) PIC (T4000 Router)” on page 55
PB-1OCHE1-T1-IQE-RJ48
“Channelized OC3/STM1 Enhanced
PB-2CHOC3-STM1-IQE-SFP
Enhanced IQ (IQE) PICs with SFP
PB-1CHOC12-STM4-IQE-SFP
DS3 and E3 PICs
PB-4DS3-E3-IQE-BNC
Fast Ethernet and Gigabit Ethernet PICs
PB-4FE-TX
Gigabit Ethernet PICs with SFP
(T4000 Router)
PB-1GE-SFP
Gigabit Ethernet IQ2 PICs
“Gigabit Ethernet IQ2 PICs with
SFP (T4000 Router)” on page 89
PB-4GE-TYPE1-SFP-IQ2
Gigabit Ethernet IQ2E PICs
“Gigabit Ethernet Enhanced IQ2
Services PICs
PB-4GE-TYPE1-SFP-IQ2E
Copyright © 2018, Juniper Networks, Inc.
Chapter 1: T4000 Interface Modules Support
12.1.R2
12.1.R2
12.1.R2
12.1.R2
12.1.R2
12.1.R2
12.1.R2
12.1.R2
12.1.R2
T640-FPC1-ES
12.1R2
12.1.R2
12.1.R2
9
T4000 Core Router Interface Module Reference
Table 12: T4000 PIC/FPC Compatibility Type 1 (continued)
Type 1 PIC PIC Model Number
PB-TUNNEL1
SONET/SDH PICs
PB-4OC3-1OC12-SON-SFP
PB-1OC12-SON-SFP
T640-FPC1-ES
12.1.R2
12.1.R2
12.1.R2
PIC/FPC Compatibility (Type 2)
provides a PIC/FPC compatibility matrix for the current Type 2 PICs for the T4000 router and Type 2 FPCs.
Table 13: T4000 PIC/FPC Compatibility Type 2
Type 2 PIC PIC Model Number T640-FPC2-ES
ATM PICs
PB-2OC12-ATM2-SMIR
Channelized IQ PICs
Enhanced IQ (IQE) PICs with SFP
PB-4CHOC12-STM4-IQE-SFP
Enhanced IQ (IQE) PIC with SFP
PB-1CHOC48-STM16-IQE-SFP
Gigabit Ethernet PICs
“Gigabit Ethernet PICs with SFP
PB-2GE-SFP
PB-4GE-SFP
12.2.R1
12.2R2
12.2R2
12.2R2
12.2R2
10 Copyright © 2018, Juniper Networks, Inc.
Chapter 1: T4000 Interface Modules Support
Table 13: T4000 PIC/FPC Compatibility Type 2 (continued)
Type 2 PIC PIC Model Number
“Gigabit Ethernet IQ PIC with SFP
PB-2GE-SFP-QPP
“Gigabit Ethernet IQ2 PICs with
SFP (T4000 Router)” on page 89
PB-8GE-TYPE2-SFP-IQ2
Services PICs
PB-MS-400-2
PB-TUNNEL
SONET/SDH PICs
PB-4OC3-1OC12-SON2-SFP
PIC (T4000 Router)” on page 171
PB-4OC12-SON-MM
PB-4OC12-SON-SMIR
PB-4OC3-4OC12-SON-SFP
PICs (T4000 Router)” on page 175
PC-4OC48-SON-SMSR
PB-1OC48-SON-SMSR
PIC with SFP (T4000 Router)” on page 179
PB-1OC48-SON-SFP
(Multi-Rate) PIC with SFP (T4000
PB-1OC48-SON-B-SFP
T640-FPC2-ES
12.2R2
12.2R2
12.2
12.2R2
12.2R2
12.2R2
12.2R2
12.1R2
12.2R2
12.2R2
12.2R2
PIC/FPC Compatibility (Type 3)
provides a PIC/FPC compatibility matrix for the current Type 3 PICs for the T4000 router and Type 3 FPCs.
Table 14: T4000 PIC/FPC Compatibility Type 3
Type 3 PIC PIC Model Number T640-FPC3-ES
Channelized IQE
Copyright © 2018, Juniper Networks, Inc.
11
T4000 Core Router Interface Module Reference
Table 14: T4000 PIC/FPC Compatibility Type 3 (continued)
Type 3 PIC PIC Model Number
Enhanced IQ (IQE) PICs with SFP
PC-4CHOC12-STM4-IQE-SFP
Gigabit Ethernet PICs
“Gigabit Ethernet PICs with SFP
PC-10GE-SFP
“Gigabit Ethernet IQ2 PICs with
SFP (T4000 Router)” on page 89
PC-8GE-TYPE3-SFP-IQ2
“Gigabit Ethernet Enhanced IQ2
PC-8GE-TYPE3-SFP-IQ2
T640-FPC3-ES
13.2
12.1R2
12.1R2
12.1R2
12 Copyright © 2018, Juniper Networks, Inc.
Table 14: T4000 PIC/FPC Compatibility Type 3 (continued)
Type 3 PIC PIC Model Number
10-Gigabit Ethernet PICs
XENPAK (T4000 Router)” on page 97
PC-1XGE-XENPAK
EOL PIC (T4000 Router)” on page 169
PC-1XGE-DWDM-OTN
“10-Gigabit Ethernet IQ2 PIC with
XFP (T4000 Router)” on page 100
PC-1XGE-TYPE3-XFP-IQ2
“10-Gigabit Ethernet IQ2E PIC with
XFP (T4000 Router)” on page 103
PC-1XGE-TYPE3-XFP-IQ2E
Services PICs
PC-MS-500-3
PC-TUNNEL
SONET/SDH PICs
PICs (T4000 Router)” on page 175
PC-4OC48-SON-SMSR
“SONET/SDH OC48c/STM16 PIC with SFP (T4000 Router)” on page 148
PC-4OC48-SON-SFP
Enhanced IQ (IQE) PIC with SFP
PC-4OC48-STM16-IQE-SFP
“SONET/SDH OC192/STM64 PICs with XFP (T4000 Router)” on page 160
PC-1OC192-SON-XFP
Chapter 1: T4000 Interface Modules Support
12.1R2
12.1R2
12.1R2
12.1R2
13.2
13.2
T640-FPC3-ES
12.2R2
12.1R2
12.1R2
12.1R2
Copyright © 2018, Juniper Networks, Inc.
13
T4000 Core Router Interface Module Reference
PIC/FPC Compatibility (Type 4)
provides a PIC/FPC compatibility matrix for the current Type 4 PICs for the T4000 router and Type 4 FPCs.
Table 15: T4000 PIC/FPC Compatibility Type 4
Type 4 PIC PIC Model Number T640-FPC4-1P-ES T1600-FPC4-ES
10-Gigabit Ethernet PICs
SFP+ (T4000 Router)” on page 110
PD-5-10XGE-SFPP 12.1R2
12.1R2
12.1
NOTE: To support
PD-5-10XGE-SFPP, the hardware version of the
T1600-FPC4-ES
(part number
710-013037) REV 13 or later is required.
12.1
PIC with XFP (T4000 Router)” on page 117
PD-4XGE-XFP
40-Gigabit Ethernet PICs
“40-Gigabit Ethernet PIC with CFP
PD-1XLE-CFP
100-Gigabit Ethernet PICs
“100-Gigabit Ethernet PIC with CFP
PD-1CE-CFP-FPC4 (PIC and FPC)
NOTE: This PIC is available only packaged in an assembly with the
T1600-FPC4-ES FPC.
SONET/SDH PICs
“SONET/SDH OC192/STM64 PICs with XFP (T4000 Router)” on page 160
PD-4OC192-SON-XFP
PIC (T4000 Router)” on page 165
PD-1OC768-SON-SR
—
—
12.1R2
12.1R2
13.2
12.1R2
12.1
12.1
PIC/FPC Compatibility (Type 5)
provides a PIC/FPC compatibility matrix for the current Type 5 PICs for the T4000 router and Type 5 FPCs.
14 Copyright © 2018, Juniper Networks, Inc.
Chapter 1: T4000 Interface Modules Support
Table 16: T4000 PIC/FPC Compatibility Type 5
Type 5 PIC PIC Model Number
10-Gigabit Ethernet PICs
PIC with SFP+ (T4000 Router)” on page 106
PF-12XGE-SFPP
SFP+ (T4000 Router)” on page 110
PF-24XGE-SFPP
100-Gigabit Ethernet PICs
“100-Gigabit Ethernet PIC with CFP
PF-1CGE-CFP
Related
Documentation
• T4000 PIC Description
•
T4000 PICs Supported on page 3
• T4000 FPCs Supported
12.1
T4000-FPC5-3D T4000-FPC5-LSR
12.1
12.3R2
12.2
12.3R2
12.3R2
Copyright © 2018, Juniper Networks, Inc.
15
T4000 Core Router Interface Module Reference
16 Copyright © 2018, Juniper Networks, Inc.
CHAPTER 2
Network Interface Specifications
•
Determining Transceiver Support and Specifications for M Series and T Series
•
10-Gigabit Ethernet DWDM OTN PIC (PC-1XGE-DWDM-OTN) Optical Interface
•
10-Gigabit Ethernet DWDM Transceiver (XFP-10G-CBAND-T50-ZR)
•
SONET/SDH OC3/STM1 Optical Interface Specifications on page 24
•
SONET/SDH OC12/STM4 Optical Interface Specifications on page 25
•
SONET/SDH OC48/STM16 Optical Interface Specifications on page 27
•
SONET/SDH OC192/STM64 Optical Interface Specifications on page 29
•
SONET/SDH OC768/STM256 Optical Interface Specifications on page 32
Determining Transceiver Support and Specifications for M Series and T Series Routers
You can find information about the pluggable transceivers supported on your Juniper
Networks device by using the Hardware Compatibility Tool. In addition to transceiver and connector type, the optical and cable characteristics—where applicable—are documented for each transceiver. The Hardware Compatibility Tool allows you to search by product, displaying all the transceivers supported on that device, or category, displaying all the transceivers by interface speed or type. The Hardware Compatibility Tool is located at https://apps.juniper.net/hct/ .
Some transceivers support additional monitoring using the operational mode CLI command show interfaces diagnostics optics . Use the Hardware Compatibility Tool to determine if your transceiver supports monitoring. See the Junos OS documentation for your device for a description of the monitoring fields.
CAUTION: If you face a problem running a Juniper Networks device that uses a third-party optic or cable, the Juniper Networks Technical Assistance Center
(JTAC) can help you diagnose the source of the problem. Your JTAC engineer might recommend that you check the third-party optic or cable and potentially replace it with an equivalent Juniper Networks optic or cable that is qualified for the device.
Copyright © 2018, Juniper Networks, Inc.
17
T4000 Core Router Interface Module Reference
10-Gigabit Ethernet DWDM OTN PIC (PC-1XGE-DWDM-OTN) Optical Interface
Specifications
•
10-Gigabit Ethernet DWDM OTN Optical Interface Specifications on page 18
•
10-Gigabit Ethernet DWDM OTN Supported Wavelengths on page 20
•
PC-1XGE-DWDM-OTN Optical Signal-to-Noise Ratio (OSNR) Performance on page 22
10-Gigabit Ethernet DWDM OTN Optical Interface Specifications
shows the optical interface specifications for the 10-Gigabit Ethernet
DWDM OTN PIC transceiver.
Table 17: 10-Gigabit Ethernet DWDM OTN Optical Interface Specifications
Model number • PIC model number: PC-1XGE-DWDM-OTN
Features
Transceiver type
Standards
Optical interface
•
•
•
10–Gigabit digital wrapper with over-clocked G.709 framing
Generic Reed-Solomon forward error correction (GFEC) and enhanced forward error correction
(EFEC) to transport 10GBASE-R (10-Gigabit Ethernet LAN PHY)
Reduced cost of deploying and maintaining the network due to:
•
•
Fewer optical-electrical-optical (OEO) conversions
Fewer optical amplifiers and regenerators
•
•
89 tunable wavelengths (channels) supported per DWDM-OTN module
Link fault switchover
• Dense wavelength division multiplexing (DWDM) module
• ITU-T G.709—Interfaces for the Optical Transport Network (OTN). The PC-1XGE-DWDM-OTN
PIC supports two OTN extended mappings:
•
•
Supplement 43, section 7.1, optical channel payload unit 2e (OPU2e). This mapping inserts the original 10GE LAN PHY signal into a “digital wrapper” with overclocked G.709 framing that results in a line rate of 11.1 Gbps instead of the standard 10.7 Gbps.
Supplement 43, section 7.2, optical channel payload unit 1e (OPU1e). This mapping inserts the original 10GE LAN PHY signal into a “digital wrapper” with overclocked G.709 framing, but without the use of fixed stuff bytes, that results in a line rate of 11.05 Gbps instead of the standard 10.7 Gbps.
See ITU-T Series G Supplement 43, ver 02/2008 for more information about OPU2e and OPU1e extended mappings.
•
•
•
ITU-T G.975—GFEC
ITU-T G.975.1—Enhanced FEC
•
•
ITU-T G.694.1—Spectral grids for WDM applications: DWDM frequency grid Series G:
Transmission Systems and Media, Digital Systems and Networks Transmission media characteristics-Characteristics of optical components and subsystems
IEEE 802.3ae—2005
RFC 3591—Definitions of Managed Objects for the Optical Interface Type
• Single-mode optical fiber
18 Copyright © 2018, Juniper Networks, Inc.
Chapter 2: Network Interface Specifications
Table 17: 10-Gigabit Ethernet DWDM OTN Optical Interface Specifications (continued)
Line interface •
•
•
•
Line rate:
10GE LAN PHY: 10.3125 Gbps (pass-through)
G.709 LAN PHY without fixed stuff bytes: 11.049 Gbps
G.709 LAN PHY with fixed stuff bytes: 11.0957 Gbps
•
•
•
Transmit line rate deviation: G.709 LAN PHY modes: +/-20 ppm
Dispersion window: +/-1200 ps/nm or +/-1600 ps/nm (maximum)
FEC type (software selectable): Generic Reed-Solomon RS (255, 239) code computed as specified in Annex A/G. 709 (GFEC) or enhanced (EFEC)
Optical transmitter
Optical receiver
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Transmitter type: LiNbO
3
MZI (Lithium Niobate Mach-Zehnder Inferometer)
Modulation format: Nonretum-to-zero (NRZ)
Channel-plan wavelength range: 1528.77 through 1563.86 nm
Channel-plan frequency range: 191.7 through 196.1 THz
Channel spacing: 50 GHz
Channel tunability: 89 channels—see
Output power (on): +3 to +7 dBm
Output power (off): ≤−40 dBm
Output power stability: −1.5 to +1.0 dB
Wavelength accuracy: +/-25 pm, +/-3.125 GHz
Tuning time: Warm tune – 10 seconds; cold start – 40 seconds
Extinction ratio: ≥ 11 dB
•
•
Crossing ratio: 45 to 55 percent
Side-mode suppression ratio: ≥ 30 dB
Optical spectral width: ≤ 25 GHz (informational, not a specification)
Average relative intensity noise (RIN):
10 MHz to 1 GHz: −110 dB/Hz
1 GHz to 10 GHz: −145 dB/Hz
•
•
•
Output OSNR:
Minimum: 50 dB (0.1 nm resolution bandwidth)
Typical: 55 dB (0.1 nm resolution bandwidth)
•
•
•
Polarization extinction ratio: 20 dB
Eye mask compliance: 802.3—2005
Jitter generation compliance: GR-253/G.8251
•
•
•
•
Receiver type: Avalanche photodiode (APD)
Average receive power (input power range): see Input Power Range in
Jitter tolerance compliance: GR-253/G.8251/802.3ae (LAN PHY)
Rx DTV setting:
•
•
•
No FEC (pass-through): Static (factory optimized value)
GFEC: Managed by electronic dispersion compensation (EDC)
EFEC: Managed by EDC
•
•
•
•
Rx wavelength range: 1527 to 1567 nm
Overload (receiver saturation): −5 dBm (high OSNR), −8 dBm (low OSNR)
Damage input power: +5 dBm
Optical return loss: ≥ 27 dB
Copyright © 2018, Juniper Networks, Inc.
19
T4000 Core Router Interface Module Reference
Table 17: 10-Gigabit Ethernet DWDM OTN Optical Interface Specifications (continued)
Optical performance Optical Applications—Power-Limited Receiver (High OSNR):
• Sensitivity:
• No FEC: −5 to −24 dBm (>33 dB/0.1 nm OSNR, 0 ps/nm CD) at 10
−12
BER (10.3 Gbps)
• GFEC: −5 to −28 dBm at 8 x 10
−5 pre-FEC BER (>33 dB/0.1 nm OSNR, 0 ps/nm CD) (10
−15 post-FEC BER) (11.05 and 11.1 Gbps)
• EFEC: −5 to −28 dBm at 1 x 10
−3 pre-FEC BER (>33 dB/0.1 nm OSNR, 0 ps/nm CD) (10
−15 post-FEC BER) (11.05 and 11.1 Gbps)
• Chromatic dispersion (CD) power penalty:
•
•
No FEC: 3 dB (typical penalty at +/-1200 ps/nm without EDC)
GFEC or EFEC: 3 dB (typical penalty at +/-1600 ps/nm with EDC)
Optical Applications—Noise-Limited Receiver (Low OSNR):
• Required OSNR:
• No FEC (10.3 Gbps):
•
•
•
26 dB/0.1 nm (−8 to −22 dBm Rx input power range, 0 ps/nm CD, at 10
−12
BER)
26 dB/0.1 nm (−8 to −20 dBm Rx input power range, +/-1000 ps/nm without EDC, at 10
−12
BER)
30 dB/0.1 nm (−8 to −20 dBm Rx input power range, +/-1200 ps/nm without EDC, at 10
−12
BER)
• GFEC (11.05 and 11.1 Gbps):
• 15.5 dB/0.1 nm (−8 to −20 dBm Rx input power range, 0 ps/nm, at ≤ 10
−5
10
−15 post-FEC BER) pre-FEC BER, ≤
• 17 dB/0.1 nm (−8 to −20 dBm Rx input power range, +/-1200 ps/nm with EDC, at ≤ 10
−5 pre-FEC BER, ≤ 10
−15 post-FEC BER)
• EFEC (11.05 and 11.1 Gbps):
• 12 dB/0.1 nm (−8 to −20 dBm Rx input power range, 0 ps/nm, at ≤ 10
−4
10
−15 post-FEC BER) pre-FEC BER, ≤
•
•
14 dB/0.1 nm (−8 to −20 dBm Rx input power range, +/-1200 ps/nm with EDC, at ≤ 10
−4 pre-FEC BER, ≤ 10
−15 post-FEC BER)
16 dB/0.1 nm (−8 to −20 dBm Rx input power range, 0 ps/nm CD, 10
−15 post-FEC BER)
• CD OSNR penalty:
• GFEC: 1.5 dB (typical penalty at +/-1200 ps/nm with Rx input power range from −8 to −20 dBm).
• EFEC: 2 dB (typical penalty at +/-1200 ps/nm with Rx input power range from −8 to −20 dBm).
For more detailed information, see
.
10-Gigabit Ethernet DWDM OTN Supported Wavelengths
provides the supported wavelengths for the 100-GHz grid and the
50-GHz offset in both THz and nm.
20 Copyright © 2018, Juniper Networks, Inc.
Chapter 2: Network Interface Specifications
Table 18: 10-Gigabit Ethernet DWDM OTN Supported Wavelengths
100–GHz Grid 50–GHz Offset 100–GHz Grid
THz nm THz nm THz nm
191.70
191.80
191.90
192.00
1563.86
1563.04
1562.23
1561.41
191.75
191.85
191.95
192.05
1563.45
1562.63
1561.82
1561.01
194.00
194.10
194.20
194.30
1545.32
1544.52
1543.73
1542.93
1538.18
1537.39
1536.60
1535.82
1535.03
1534.25
1542.14
1541.34
1540.55
1539.76
1538.97
1533.46
1532.68
1531.89
1531.11
1530.33
1529.55
1528.77
194.90
195.00
195.10
195.20
195.30
195.40
194.40
194.50
194.60
194.70
194.80
195.50
195.60
195.70
195.80
195.90
196.00
196.10
1556.15
1555.34
1554.53
1553.73
1552.92
1552.12
1560.20
1559.38
1558.57
1557.76
1556.95
1551.31
1550.51
1549.71
1548.91
1548.11
1547.31
1546.51
1545.72
192.65
192.75
192.85
192.95
193.05
193.15
192.15
192.25
192.35
192.45
192.55
193.25
193.35
193.45
193.55
193.65
193.75
193.85
193.95
1556.55
1555.74
1554.94
1554.13
1553.32
1552.52
1560.60
1559.79
1558.98
1558.17
1557.36
1551.72
1550.91
1550.11
1549.31
1548.51
1547.71
1546.91
1546.11
192.60
192.70
192.80
192.90
193.00
193.10
192.10
192.20
192.30
192.40
192.50
193.20
193.30
193.40
193.50
193.60
193.70
193.80
193.90
50–GHz Offset
THz nm
194.05
194.15
194.25
194.35
1544.92
1544.12
1543.33
1542.53
1537.79
1537.00
1536.21
1535.42
1534.64
1533.85
1541.74
1540.95
1540.16
1539.37
1538.58
1533.07
1532.28
1531.50
1530.72
1529.94
1529.16
194.95
195.05
195.15
195.25
195.35
195.45
194.45
194.55
194.65
194.75
194.85
195.55
195.65
195.75
195.85
195.95
196.05
Copyright © 2018, Juniper Networks, Inc.
21
T4000 Core Router Interface Module Reference
PC-1XGE-DWDM-OTN Optical Signal-to-Noise Ratio (OSNR) Performance
The OSNR performance listed in
is for an appropriate level of optical filtering of the amplified spontaneous emission (ASE) reaching the receiver and is derived using a 0.22-nm 3-dB full-width Gaussian filter. When no FEC is used, there is no OTN framing.
Table 19: PC-1XGE-DWDM-OTN Optical Signal-to-Noise Ratio (OSNR) Performance
OSNR (dB/0.1
nm)
OSNR
(dB/0.5 nm) FEC Type
Pre-FEC
BER
Post-FEC
BER
Input-Power
Range
(ROP)
(dBm)
CD Tolerance
(ps/nm)
33 26 None 10
–12
NA –5 to –24 0
33
26
26
19
None
None
10
–12
10
–12
NA
NA
–5 to –21
–8 to –22
+/-1200 (no EDC)
0
26
30
33
33
15.5
17
33
33
12
14
19
23
26
26
8.5
10
26
26
5
7
None
None
GFEC
GFEC
GFEC
GFEC
EFEC
EFEC
EFEC
EFEC
10
–5
10
–5
10
–3
10
–12
10
–12
8 x 10
–5
8 x 10
–5
10
–3
7 x 10
–4
7 x 10
–4
NA
10
–15
10
–15
10
–15
NA
10
–15
10
–15
10
–15
10
–15
10
–15
–8 to –20
–8 to –20
–5 to –28
–5 to –25
–8 to –20
–8 to –20
–5 to –28
–5 to –25
–8 to –20
–8 to –20
+/-1000 (no EDC)
+/-1200 (no EDC)
0
+/-1600 (with EDC)
0
+/-1200 (with EDC)
0
+/-1600 (with EDC)
0
+/-1200 (with EDC)
10-Gigabit Ethernet DWDM Transceiver (XFP-10G-CBAND-T50-ZR) Wavelengths
provides the supported wavelengths for the 100-GHz grid and the
50-GHz offset in both THz and nm.
22 Copyright © 2018, Juniper Networks, Inc.
Chapter 2: Network Interface Specifications
Table 20: Programmable Wavelengths Supported by 10-Gigabit Ethernet DWDM Transceivers
100–GHz Grid 50–GHz Offset 100–GHz Grid 50–GHz Offset
THz nm THz nm THz nm THz nm
191.70
191.80
191.90
192.00
1563.86
1563.04
1562.23
1561.41
191.75
191.85
191.95
192.05
1563.45
1562.63
1561.82
1561.01
194.00
194.10
194.20
194.30
1545.32
1544.52
1543.73
1542.93
194.05
194.15
194.25
194.35
1544.92
1544.12
1543.33
1542.53
1537.79
1537.00
1536.21
1535.42
1534.64
1533.85
1541.74
1540.95
1540.16
1539.37
1538.58
1533.07
1532.28
1531.50
1530.72
1529.94
1529.16
194.95
195.05
195.15
195.25
195.35
195.45
194.45
194.55
194.65
194.75
194.85
195.55
195.65
195.75
195.85
195.95
196.05
1538.18
1537.39
1536.60
1535.82
1535.03
1534.25
1542.14
1541.34
1540.55
1539.76
1538.97
1533.46
1532.68
1531.89
1531.11
1530.33
1529.55
1528.77
194.90
195.00
195.10
195.20
195.30
195.40
194.40
194.50
194.60
194.70
194.80
195.50
195.60
195.70
195.80
195.90
196.00
196.10
1556.15
1555.34
1554.53
1553.73
1552.92
1552.12
1560.20
1559.38
1558.57
1557.76
1556.95
1551.31
1550.51
1549.71
1548.91
1548.11
1547.31
1546.51
1545.72
192.65
192.75
192.85
192.95
193.05
193.15
192.15
192.25
192.35
192.45
192.55
193.25
193.35
193.45
193.55
193.65
193.75
193.85
193.95
1556.55
1555.74
1554.94
1554.13
1553.32
1552.52
1560.60
1559.79
1558.98
1558.17
1557.36
1551.72
1550.91
1550.11
1549.31
1548.51
1547.71
1546.91
1546.11
192.60
192.70
192.80
192.90
193.00
193.10
192.10
192.20
192.30
192.40
192.50
193.20
193.30
193.40
193.50
193.60
193.70
193.80
193.90
Copyright © 2018, Juniper Networks, Inc.
23
T4000 Core Router Interface Module Reference
Related
Documentation
• Ethernet DWDM Interface Wavelength Overview
• Configuring the 10-Gigabit or 100-Gigabit Ethernet DWDM Interface Wavelength
SONET/SDH OC3/STM1 Optical Interface Specifications
•
SONET/SDH OC3/STM1 Specifications on page 24
•
SONET/SDH OC3/STM1 Intermediate Reach (IR-1) Specifications on page 24
•
SONET/SDH OC3/STM1 Long Reach (LR-1) Specifications on page 25
SONET/SDH OC3/STM1 Specifications
shows the multimode SONET/SDH OC3/STM1 optical interface specifications.
Table 21: SONET/SDH OC3/STM1 Multimode Optical Interface Specifications
Parameter Multimode
Optical interface
Maximum distance
Standard
Transmitter wavelength
Average launch power
Receiver saturation
Receiver sensitivity
Multimode
MMF cable: 1.2 miles (2 km)
Multivendor agreement
1270 through 1380 nm
–20 through –14 dBm
–14 dBm
–30 dBm
SONET/SDH OC3/STM1 Intermediate Reach (IR-1) Specifications
shows the SONET/SDH OC3/STM1 intermediate reach (IR-1) optical interface specifications.
Table 22: SONET/SDH OC3/STM1 Intermediate Reach Optical Interface Specifications
Parameter Intermediate Reach (IR-1)
Optical interface Single-mode
Maximum distance
Standard
Transmitter wavelength
Average launch power
SMF cable: 9.3 miles (15 km)
Telcordia GR-253
1261 through 1360 nm
–15 through –8 dBm
24 Copyright © 2018, Juniper Networks, Inc.
Chapter 2: Network Interface Specifications
Table 22: SONET/SDH OC3/STM1 Intermediate Reach Optical Interface
Specifications (continued)
Parameter Intermediate Reach (IR-1)
Receiver saturation
Receiver sensitivity
–8 dBm
–28 dBm
SONET/SDH OC3/STM1 Long Reach (LR-1) Specifications
shows the SONET/SDH OC3/STM1 long reach (LR-1) optical interface specifications.
Table 23: SONET/SDH OC3/STM1 Long Reach -1 Optical Interface Specifications
Parameter Long Reach (LR-1)
Optical interface
Maximum distance
Standard
Transmitter wavelength
Average launch power
Receiver saturation
Receiver sensitivity
Single-mode
SMF cable: 24.85 miles (40 km)
Telcordia GR-253
1263 through 1360 nm
–5 through 0 dBm
–10 dBm
–34 dBm
SONET/SDH OC12/STM4 Optical Interface Specifications
•
SONET/SDH OC12/STM4 Short Reach (SR-1) Specifications on page 25
•
SONET/SDH OC12/STM4 Intermediate Reach (IR-1) Specifications on page 26
•
SONET/SDH OC12/STM4 Long Reach (LR-1) Specifications on page 26
•
SONET/SDH OC12/STM4 Long Reach (LR-2) Specifications on page 27
SONET/SDH OC12/STM4 Short Reach (SR-1) Specifications
shows the SONET/SDH OC12/STM4 short reach (SR-1) optical interface specifications.
Table 24: SONET/SDH OC12/STM4 Short Reach (SR-1) Optical Interface Specifications
Parameter Short Reach (SR-1)
Optical interface Single-mode
Copyright © 2018, Juniper Networks, Inc.
25
T4000 Core Router Interface Module Reference
Table 24: SONET/SDH OC12/STM4 Short Reach (SR-1) Optical Interface
Specifications (continued)
Parameter Short Reach (SR-1)
Maximum distance
Standard
Transmitter wavelength
Average launch power
Receiver saturation
Receiver sensitivity
SMF cable: 1.24 miles (2 km)
Telcordia GR-253
1261 through 1360 nm
–15 through –8 dBm
–8 dBm
–23 dBm
SONET/SDH OC12/STM4 Intermediate Reach (IR-1) Specifications
shows the SONET/SDH OC12/STM4 short reach (IR-1) optical interface specifications.
Table 25: SONET/SDH OC12/STM4 Intermediate Reach (IR-1) Optical Interface
Specifications
Parameter Intermediate Reach (IR-1)
Optical interface
Maximum distance
Standard
Transmitter wavelength
Average launch power
Receiver saturation
Receiver sensitivity
Single-mode
SMF cable: 9.3 miles (15 km)
Telcordia GR-253
1274 through 1356 nm
–15 through –8 dBm
–8 dBm
–28 dBm
SONET/SDH OC12/STM4 Long Reach (LR-1) Specifications
shows the SONET/SDH OC12/STM4 short reach (LR-1) optical interface specifications.
Table 26: SONET/SDH OC12/STM4 Long Reach (LR-1) Optical Interface Specifications
Parameter Long Reach (LR-1)
Optical interface Single-mode
26 Copyright © 2018, Juniper Networks, Inc.
Chapter 2: Network Interface Specifications
Table 26: SONET/SDH OC12/STM4 Long Reach (LR-1) Optical Interface
Specifications (continued)
Parameter Long Reach (LR-1)
Maximum distance
Standard
Transmitter wavelength
Average launch power
Receiver saturation
Receiver sensitivity
SMF cable: 24.85 miles (40 km)
Telcordia GR-253
1280 through 1335 nm
–3 through +2 dBm
–8 dBm
–28 dBm
SONET/SDH OC12/STM4 Long Reach (LR-2) Specifications
shows the SONET/SDH OC12/STM4 short reach (LR-2) optical interface specifications.
Table 27: SONET/SDH OC12/STM4 Long Reach (LR-2) Optical Interface Specifications
Parameter Long Reach (LR-2)
Optical interface
Maximum distance
Standard
Transmitter wavelength
Average launch power
Receiver saturation
Receiver sensitivity
Single-mode
SMF cable: 49.70 miles (80 km)
Telcordia GR-253
1480 through 1580 nm
–3 through 2 dBm
–8 dBm
–28 through –8 dBm
SONET/SDH OC48/STM16 Optical Interface Specifications
•
SONET/SDH OC48/STM16 Short Reach (SR-1) Specifications on page 28
•
SONET/SDH OC48/STM16 Intermediate Reach (IR-1) Specifications on page 28
•
SONET/SDH OC48/STM16 Long Reach (LR-1) Specifications on page 28
•
SONET/SDH OC48/STM16 Long Reach (LR-2) Specifications on page 29
Copyright © 2018, Juniper Networks, Inc.
27
T4000 Core Router Interface Module Reference
SONET/SDH OC48/STM16 Short Reach (SR-1) Specifications
shows the SONET/SDH OC48/STM16 short reach (SR-1) optical interface specifications.
Table 28: SONET/SDH OC48/STM16 Short Reach (SR-1) Optical Interface Specifications
Parameter Short Reach (SR-1)
Optical interface
Maximum distance
Standard
Transmitter wavelength
Average launch power
Receiver saturation
Receiver sensitivity
Single-mode
SMF cable: 1.24 miles (2 km)
Telcordia GR-253
1266 through 1360 nm
–10 through –3 dBm
–3 dBm
–18 dBm
SONET/SDH OC48/STM16 Intermediate Reach (IR-1) Specifications
shows the SONET/SDH OC48/STM16 intermediate reach (IR-1) optical interface specifications.
Table 29: SONET/SDH OC48/STM16 Intermediate Reach (IR-1) Optical Interface
Specifications
Parameter Intermediate Reach (IR-1)
Optical interface
Maximum distance
Standard
Transmitter wavelength
Average launch power
Receiver saturation
Receiver sensitivity
Single-mode
SMF cable: 9.3 miles (15 km)
Telcordia GR-253
1260 through 1360 nm
–5 through 0 dBm
0 dBm
–18 dBm
SONET/SDH OC48/STM16 Long Reach (LR-1) Specifications
shows the SONET/SDH OC48/STM16 long reach (LR-1) optical interface specifications.
28 Copyright © 2018, Juniper Networks, Inc.
Chapter 2: Network Interface Specifications
Table 30: SONET/SDH OC48/STM16 Long Reach (LR-1) Optical Interface Specifications
Parameter Long Reach (LR-1)
Optical interface
Maximum distance
Standard
Transmitter wavelength
Average launch power
Receiver saturation
Receiver sensitivity
Single-mode
SMF cable: 28.85 miles (40 km)
Telcordia GR-253
1280 through 1335 nm
–2 through +3 dBm
–9 dBm
–28 dBm
SONET/SDH OC48/STM16 Long Reach (LR-2) Specifications
shows the SONET/SDH OC48/STM16 long reach (LR-2) optical interface specifications.
Table 31: SONET/SDH OC48/STM16 Long Reach (LR-2) Optical Interface Specifications
Parameter Long Reach (LR-2)
Optical interface
Maximum distance
Standard
Transmitter wavelength
Average launch power
Receiver saturation
Receiver sensitivity
Single-mode
SMF cable: 49.71 miles (80 km)
Telcordia GR-253
1500 through 1580 nm
–2 through +3 dBm
–9 dBm
–28 dBm
SONET/SDH OC192/STM64 Optical Interface Specifications
•
SONET/SDH OC192/STM64 Very Short Reach (VSR) on page 30
•
SONET/SDH OC192/STM64 Short Reach (SR-1) on page 30
•
SONET/SDH OC192/STM64 Short Reach (SR-2) on page 31
•
SONET/SDH OC192/STM64 Intermediate Reach (IR-2) on page 31
•
SONET/SDH OC192/STM64 Long reach (LR-1) on page 32
•
SONET/SDH OC192/STM64 Long reach (LR-2) on page 32
Copyright © 2018, Juniper Networks, Inc.
29
T4000 Core Router Interface Module Reference
SONET/SDH OC192/STM64 Very Short Reach (VSR)
shows the SONET/SDH OC192/STM64 very short reach (VSR) optical interface specifications.
Table 32: SONET/SDH OC192/STM64 Very Short Reach (VSR 1) Optical Interface
Specifications
Parameter Very Short Reach (VSR)
Optical interface
Maximum distance
Standard
Transmitter wavelength
Average launch power
Receiver saturation
Receiver sensitivity
Multimode
MMF cable: 984.25 feet (300 m)
OIF VSR4–1
830 through 860 nm
–10 through –3 dBm
–3 dBm
–16 dBm
SONET/SDH OC192/STM64 Short Reach (SR-1)
shows the SONET/SDH OC192/STM64 short reach (SR-1) optical interface specifications.
Table 33: SONET/SDH OC192/STM64 Short Reach (SR-1) Optical Interface
Specifications
Parameter Short Reach (SR-1)
Optical interface
Maximum distance
Standard
Transmitter wavelength
Average launch power
Receiver saturation
Receiver sensitivity
Single-mode
SMF cable: 6.21 miles (10 km)
Telcordia GR-253 OC192 SR1
1290 nm through 1330 nm
–6 through –1 dBm
–1.0 dBm
–11 dBm
30 Copyright © 2018, Juniper Networks, Inc.
Chapter 2: Network Interface Specifications
SONET/SDH OC192/STM64 Short Reach (SR-2)
shows the SONET/SDH OC192/STM64 short reach (SR-2) optical interface specifications.
Table 34: SONET/SDH OC192/STM64 Short Reach (SR-2) Optical Interface
Specifications
Parameter Short Reach (SR-2)
Optical interface
Maximum distance
Standard
Transmitter wavelength
Average launch power
Receiver saturation
Receiver sensitivity
Single-mode
SMF cable: 15.5 miles (25 km)
Telcordia GR-253 OC192 SR2
1530 through 1565 nm
–4 through 0 dBm
–3 dBm
–14 dBm
SONET/SDH OC192/STM64 Intermediate Reach (IR-2)
shows the SONET/SDH OC192/STM64 Intermediate reach (IR-2) optical interface specifications.
Table 35: SONET/SDH OC192/STM64 Intermediate Reach (IR-2) Optical Interface
Specifications
Parameter Intermediate Reach (IR-2)
Optical interface
Maximum distance
Standard
Transmitter wavelength
Average launch power
Receiver saturation
Receiver sensitivity
Single-mode
SMF cable: 24.8 miles (40 km)
NOTE: Distances greater than 30 km are considered to be engineered links.
Telcordia GR-253 OC192 IR2
1530 nm through 1565 nm
–1.0. through 2 dBm
–1.0 dBm
–14 dBm
Copyright © 2018, Juniper Networks, Inc.
31
T4000 Core Router Interface Module Reference
SONET/SDH OC192/STM64 Long reach (LR-1)
shows the SONET/SDH OC192/STM64 long reach (LR-1) optical interface specifications.
Table 36: SONET/SDH OC192/STM64 Long Reach (LR-1) Optical Interface Specifications
Parameter Long Reach (LR-1)
Optical interface
Maximum distance
Standard
Transmitter wavelength
Average launch power
Receiver saturation
Receiver sensitivity
Single-mode
SMF cable: 49.71 miles (80 km)
Telcordia GR-253 OC192 LR2
1530 nm through 1565 nm
6 through 8 dBm
–10 dBm
–22 dBm
SONET/SDH OC192/STM64 Long reach (LR-2)
shows the SONET/SDH OC192/STM64 long reach (LR-2) optical interface specifications.
Table 37: SONET/SDH OC192/STM64 Long Reach (LR-2) Optical Interface Specifications
Parameter Long Reach (LR-2)
Optical interface
Maximum distance
Standard
Transmitter wavelength
Average launch power
Receiver saturation
Receiver sensitivity
Single-mode
SMF cable: 49.71 miles (80 km)
Telcordia GR-253 OC192 LR2
1530 nm through 1565 nm
0 through 4 dBm
–7 dBm
–24 dBm
SONET/SDH OC768/STM256 Optical Interface Specifications
shows the SONET/SDH OC768/STM256 short reach (SR-1) optical interface specifications.
32 Copyright © 2018, Juniper Networks, Inc.
Chapter 2: Network Interface Specifications
Table 38: SONET/SDH OC768/STM256 Short Reach (SR-1) Optical Interface
Specifications
Parameter Short Reach (SR-1)
Optical interface
Maximum distance
Standard
Transmitter wavelength
Average launch power
Receiver saturation
Receiver sensitivity
Single-mode
1.24 miles (2 km)
300–pin multi-source agreement (MSA) ITU G.693
VSR2000–3R2
1530 through 1565 nm
0 through +3 dBm
+3 dBm
–6 dBm
Copyright © 2018, Juniper Networks, Inc.
33
T4000 Core Router Interface Module Reference
34 Copyright © 2018, Juniper Networks, Inc.
PART 2
PIC Descriptions
•
ATM2 IQ PIC Descriptions on page 37
•
Channelized PIC Descriptions on page 43
•
Channelized Enhanced IQ (IQE) PIC Descriptions on page 51
•
DS3 and E3 PIC Descriptions on page 77
•
Fast Ethernet PIC Descriptions on page 81
•
Gigabit Ethernet PIC Descriptions on page 83
•
10-Gigabit Ethernet PIC Descriptions on page 97
•
40-Gigabit Ethernet PIC Descriptions on page 121
•
100-Gigabit Ethernet PIC Descriptions on page 125
•
Services PIC Descriptions on page 133
•
SONET/SDH PIC Descriptions on page 139
•
End-of-Life PIC Descriptions on page 169
Copyright © 2018, Juniper Networks, Inc.
35
T4000 Core Router Interface Module Reference
36 Copyright © 2018, Juniper Networks, Inc.
CHAPTER 3
ATM2 IQ PIC Descriptions
•
ATM2 OC12/STM4 IQ PIC (T4000 Router) on page 37
ATM2 OC12/STM4 IQ PIC (T4000 Router)
Figure 1: 2-Port ATM2 OC12/STM4 IQ PIC
•
•
•
•
Cables and Connectors on page 40
•
•
Alarms, Errors, and Events on page 40
Software Release
2-port: Junos OS Release 12.2R2 and later (Type 2)
For information on which FPCs support this PIC, see
“T4000 PIC/FPC Compatibility” on page 8 .
Hardware Features
• Two OC12 ports
• Power requirement: 0.52 A @ 48 V (25 W)
Copyright © 2018, Juniper Networks, Inc.
37
T4000 Core Router Interface Module Reference
• Fine-grained queuing per logical interface
• Conforms to ANSI T1.105-1991 and T1E1.2/93-020R1
• Complies with ATM and SONET/SDH standards
• Alarm and event counting and detection
• Compatible with well-known ATM switches
• ATM switch ID, which displays the switch IP address and local interface name of the adjacent Fore ATM switches
• Model number: PB-2OC12-ATM2-SMIR
• ATM2 IQ 2-port OC12 PICs have dual 3010 SAR for segmentation and reassembly into
53-byte ATM cells
• High-performance parsing of SONET/SDH frames
• ASIC-based packet segmentation and reassembly (SAR) management and output port queuing
• 64 MB SDRAM memory for ATM SAR
• Packet buffering, Layer 2 parsing
Software Features
Table 39: Software Features Supported
Software Feature
T4000 First Supported Junos
OS Release
Circuit cross-connect for leveraging ATM access networks
User-configurable virtual circuit (VC) and virtual path (VP) support
12.2R2
12.2R2
Support for idle cell or unassigned cell transmission 12.2R2
OAM fault management processes alarm indication signal (AIS), remote defect indication
(RDI), and loop cells
12.2R2
Point-to-point and point-to-multipoint mode Layer 2 counters per VC and per VP
Local and remote loopback
12.2R2
12.2R2
ATM Inverse ARP, which enables routers to automatically learn the IP address of the router on the far end of an ATM PVC
12.2R2
Simple Network Management Protocol (SNMP):
•
•
•
Management Information Base (MIB) 2 (RFC 1213)
ATM MIB (RFC 1695)
SONET MIB
12.2R2
38 Copyright © 2018, Juniper Networks, Inc.
Chapter 3: ATM2 IQ PIC Descriptions
Table 39: Software Features Supported (continued)
Software Feature
Unspecified bit rate (UBR), non-real-time variable bit rate (VBR), and constant bit rate
(CBR) traffic shaping
Per-VC or per-VP traffic shaping
Support for F4 OAM cells
Support for 16-bit VCI range
T4000 First Supported Junos
OS Release
12.2R2
12.2R2
12.2R2
12.2R2
Copyright © 2018, Juniper Networks, Inc.
39
T4000 Core Router Interface Module Reference
Cables and Connectors
• Duplex SC connector (Rx and Tx)
• SONET/SDH OC12/STM4 fixed transceivers:
• Multimode
• Intermediate reach (IR-1)
Optical interface specifications—see
“SONET/SDH OC12/STM4 Optical Interface
LEDs
Table 40: ATM2 OC12/STM4 IQ PIC LEDs
Label Color
STATUS —
Green
Yellow
Red
State
Off
On steadily
On steadily
On steadily
Description
Not enabled
Online with no alarms or failures
Online with alarms for remote failures
Active with a local alarm; router has detected a failure
Alarms, Errors, and Events
• Alarm indication signal—line (AIS-L)
• Alarm indication signal—path (AIS-P)
• Bit error rate—signal degrade (BERR-SD)
• Bit error rate—signal fail (BERR-SF)
• Loss of cell delineation (LOC)
• Loss of frame (LOF)
• Loss of pointer (LOP-P)
• Loss of signal (LOS)
• Payload mismatch (PLM-P)
• Payload unequipped (unequipped STS at path level) (UNEQ-P)
• Remote defect indication—line (RDI-L)
• Remote defect indication—path (RDI-P)
• Error detection:
• Bit interleaved parity errors B1, B2, B3
• Errored seconds (ES-S, ES-L, ES-P)
40 Copyright © 2018, Juniper Networks, Inc.
Chapter 3: ATM2 IQ PIC Descriptions
• Far-end bit errors, remote error indication—line (REI-L), far-end line coding violations
(CV-LFE)
• Far-end bit errors, remote error indication—path (REI-P), far-end path coding violations (CV-PFE)
• Far-end errored seconds (ES-LFE, ES-PFE)
• Far-end severely errored seconds (SES-LFE, SES-PFE)
• Far-end unavailable seconds (UAS-LFE, UAS-PFE)
• Severely errored framing (SEF)
• Severely errored framing seconds (SEFS-S)
• Severely errored seconds (SES-S, SES-L, SES-P)
• Unavailable seconds (UAS-L, UAS-P)
Related
Documentation
• T4000 PIC Description
•
T4000 PICs Supported on page 3
Copyright © 2018, Juniper Networks, Inc.
41
T4000 Core Router Interface Module Reference
42 Copyright © 2018, Juniper Networks, Inc.
CHAPTER 4
Channelized PIC Descriptions
•
Channelized DS3 IQ PIC (T4000 Router) on page 43
•
Channelized STM1 IQ PIC (T4000 Router) on page 46
•
Channelized OC3 IQ PIC (T4000 Router) on page 48
Channelized DS3 IQ PIC (T4000 Router)
•
•
•
•
Cables and Connectors on page 44
•
•
Alarms, Errors, and Events on page 45
•
Instrumentation (counters) on page 45
Software Release
Junos OS Release 12.1R2 and later (Type 1)
For information on which FPCs support this PIC, see
“T4000 PIC/FPC Compatibility” on page 8 .
Copyright © 2018, Juniper Networks, Inc.
43
T4000 Core Router Interface Module Reference
Hardware Features
• Four DS3 ports
• Power requirement: 0.32 A @ 48 V (15.6 W)
• Fine-grained queuing per logical interface
• Channelization: DS3, DS0
• Model number: PB-4CHDS3-QPP
• Data service unit (DSU) functionality
• Subrate and scrambling:
• Digital Link/Quick Eagle
• Kentrox
• Larscom
• ADTRAN
• Verilink
• B3ZS line encoding
• M13 or C-bit parity
• Full bit error rate test (BERT)
• Local and remote loopback testing
Software Features
Table 41: Software Features Supported
Software Feature
Quality of service (QoS) per channel: weighted round-robin (WRR), random early detection (RED), weighted random early detection (WRED)
Simple Network Management Protocol (SNMP): DS1 MIB, DS3 MIB
Dynamic, arbitrary channel configuration
Encapsulations:
•
•
•
•
Circuit cross-connect (CCC)
Frame Relay
High-Level Data Link Control (HDLC)
Point-to-Point Protocol (PPP)
Cables and Connectors
Standard DS3 BNC coaxial cable interfaces
T4000 First Supported Junos OS
Release
12.1R2
12.1R2
12.1R2
12.1R2
44 Copyright © 2018, Juniper Networks, Inc.
Chapter 4: Channelized PIC Descriptions
LEDs
Table 42: Channelized DS3 IQ PIC LEDs
Label Color
STATUS —
Green
Yellow
Red
State
Off
On steadily
On steadily
On steadily
Description
Not enabled
Online with no alarms or failures
Online with alarms for remote failures
Active with a local alarm; router has detected a failure
Alarms, Errors, and Events
• Alarm indication signal (AIS)
• Excessive zeros (EXZ)
• Far-end block error (FEBE)
• Frame error
• Idle code, Idle received
• Line code violation (LCV)
• Loss of signal (LOS)
• Out of frame (OOF)
• Parity bit (P-bit) disagreements
• Path parity error
• Yellow alarm bit (X-bit) disagreements
Instrumentation (counters)
Layer 2 per-queue and per-channel packet and byte counters
Related
Documentation
• T4000 PIC Description
•
T4000 PICs Supported on page 3
Copyright © 2018, Juniper Networks, Inc.
45
T4000 Core Router Interface Module Reference
Channelized STM1 IQ PIC (T4000 Router)
46
Software release • Junos OS Release 12.1R2 and later (Type 1)
For information on which FPCs support this PIC, see
“T4000 PIC/FPC Compatibility” on page 8 .
Description
Hardware features
Software features
•
•
•
•
•
One STM1 port
Power requirement: 0.39 A @ 48 V (18.6 W)
Fine-grained queuing per logical interface
Channelization: STM1c, fractional E1, framed and unframed DS0
Model number: PB-1CHSTM1-SMIR-QPP
•
•
Packet buffering, Layer 2 parsing
Local and remote loopback testing
• Quality of service (QoS) per channel: weighted round-robin (WRR), random early detection
(RED), weighted random early detection (WRED)
•
•
•
•
•
•
•
•
•
SNMP: SONET/SDH MIB, T1/E1 MIB
Dynamic, arbitrary channel configuration
Full bit error rate test (BERT) patterns at E1 and DS0 levels
Encapsulations:
High-Level Data Link Control (HDLC)
Frame Relay
Circuit cross-connect (CCC)
Translational cross-connect (TCC)
Point-to-Point Protocol (PPP)
Cables and connectors
•
•
•
•
Duplex SC/PC connector (Rx and Tx)
Single-mode fiber
Intermediate-reach fixed transceiver
Optical interface specifications—see
“SONET/SDH OC3/STM1 Optical Interface Specifications” on page 24
NOTE: This PIC supports only SDH.
Copyright © 2018, Juniper Networks, Inc.
Chapter 4: Channelized PIC Descriptions
LEDs
Alarms, errors, and events
Instrumentation
(counters)
One tricolor per port:
•
•
•
•
Off—Not enabled
Green—Online with no alarms or failures
Yellow—Online with alarms for remote failures
Red—Active with a local alarm; router has detected a failure
•
•
•
•
•
•
•
•
•
•
•
•
Alarm indication signal—line (AIS-L)
Alarm indication signal—path (AIS-P)
Bit error rate—signal degrade (BERR-SD)
Bit error rate—signal fail (BERR-SF)
Bit interleaved parity errors B1, B2, B3 (CV-S, CV-L, CV-P)
Loss of frame (LOF)
Loss of pointer (LOP-P)
Loss of signal (LOS)
Payload mismatch (PLM-P)
Payload unequipped (unequipped STS at path level) (UNEQ-P)
Remote defect indication—line (RDI-L)
Remote defect indication—path (RDI-P)
Error detection:
•
•
•
•
•
•
•
•
•
•
Errored seconds (ES-S, ES-L, ES-P)
Far-end bit errors, remote error indication—line (REI-L), far-end line coding violations (CV-LFE)
Far-end bit errors, remote error indication—path (REI-P), far-end path coding violations (CV-PFE)
Far-end errored seconds (ES-LFE, ES-PFE)
Far-end severely errored seconds (SES-LFE, SES-PFE)
Far-end unavailable seconds (UAS-LFE, UAS-PFE)
Severely errored framing (SEF)
Severely errored framing seconds (SEFS-S)
Severely errored seconds (SES-S, SES-L, SES-P)
Unavailable seconds (UAS-L, UAS-P)
• Layer 2 per-queue and per-channel packet and byte counters
Related
Documentation
• T4000 PIC Description
•
T4000 PICs Supported on page 3
Copyright © 2018, Juniper Networks, Inc.
47
T4000 Core Router Interface Module Reference
Channelized OC3 IQ PIC (T4000 Router)
48
Software release
Description
Hardware features
• Junos OS Release 12.1R2 and later (Type 1)
For information on which FPCs support this PIC, see
“T4000 PIC/FPC Compatibility” on page 8 .
•
•
•
•
•
One OC3 port
Power requirement: 0.39 A @ 48 V (18.6 W)
Fine-grained queuing per logical interface
Channelization: DS3, DS1, DS0
Model number: PB-1CHOC3-SMIR-QPP
• Subrate and scrambling:
•
•
•
•
•
Digital Link/Quick Eagle
Kentrox
Larscom
ADTRAN
Verilink
•
•
•
•
Packet buffering, Layer 2 parsing
M13/C-bit parity encoding
DS3 far-end alarm and control (FEAC) channel support
Local and remote loopback testing
Copyright © 2018, Juniper Networks, Inc.
Chapter 4: Channelized PIC Descriptions
Software features • Quality of service (QoS) per channel: weighted round-robin (WRR), random early detection
(RED), weighted random early detection (WRED)
Simple Network Management Protocol (SNMP): OC3 MIB, DS3 MIB, T1 MIB •
•
•
•
Dynamic, arbitrary channel configuration
Full bit error rate test (BERT)
•
•
•
•
•
Encapsulations:
Circuit cross-connect (CCC)
Translational cross-connect (TCC)
Frame Relay
High-Level Data Link Control (HDLC)
Point-to-Point Protocol (PPP)
Cables and connectors •
•
•
Duplex SC/PC connector (Rx and Tx)
Single-mode fiber SONET/SDH OC3/STM1 intermediate-reach (IR-1) fiber
Optical interface specifications—see
“SONET/SDH OC3/STM1 Optical Interface Specifications” on page 24
LEDs
Alarms, errors, and events
One tricolor per port:
•
•
•
•
Off—Not enabled
Green—Online with no alarms or failures
Yellow—Online with alarms for remote failures
Red—Active with a local alarm; router has detected a failure
•
•
•
•
Alarm indication signal (AIS-L, AIS-P)
Bit error rate signal degrade (BERR-SD), bit error rate signal fail (BERR-SF)
Bit interleaved parity errors B1, B2, B3
Errored seconds (ES-S, ES-L, ES-P), far-end bit errors REI-L, REI-P (CV-LFE, CV-PFE), Far-end block error (FEBE), far-end errored seconds (ES-LFE, ES-PFE), far-end severely errored seconds
(SES-LFE, SES-PFE), far-end unavailable seconds (UAS-LFE, UAS-PFE)
Frame error
•
•
•
•
•
•
•
•
• Idle code, Idle received
Loss of frame (LOF), loss of pointer (LOP-P), loss of signal (LOS)
Out of frame (OOF)
Payload mismatch (PLM-P), payload unequipped (UNEQ-P)
Parity bit (P-bit) disagreements
Path parity error
Remote defect indication (RDI-L, RDI-P)
Severely errored framing (SEF), severely errored framing seconds (SEFS-S), severely errored seconds (SES-S, SES-L, SES-P), unavailable seconds (UAS-L, UAS-P)
• Yellow alarm bit (X-bit) disagreements
Related
Documentation
• T4000 PIC Description
•
T4000 PICs Supported on page 3
Copyright © 2018, Juniper Networks, Inc.
49
T4000 Core Router Interface Module Reference
50 Copyright © 2018, Juniper Networks, Inc.
CHAPTER 5
Channelized Enhanced IQ (IQE) PIC
Descriptions
•
Channelized DS3/E3 Enhanced IQ (IQE) PIC (T4000 Router) on page 52
•
Channelized E1/T1 Enhanced IQ (IQE) PIC (T4000 Router) on page 55
•
Channelized OC3/STM1 Enhanced IQ (IQE) PIC with SFP (T4000 Router) on page 58
•
Channelized OC12/STM4 Enhanced IQ (IQE) PICs with SFP (T4000 Router) on page 62
•
Channelized OC48/STM16 Enhanced IQ (IQE) PIC with SFP (T4000 Router) on page 69
Copyright © 2018, Juniper Networks, Inc.
51
T4000 Core Router Interface Module Reference
Channelized DS3/E3 Enhanced IQ (IQE) PIC (T4000 Router)
52
Software release
Description
Hardware features
• Junos OS Release 12.1R2 and later (Type 1)
For information on which FPCs support this PIC, see
“T4000 PIC/FPC Compatibility” on page 8 .
•
•
•
Four E3 or Channelized DS3 ports
E3 or Channelized DS3 is configurable on a per-port granularity
DS3 channelization:
•
•
•
4 DS3 channels
112 DS1 channels
1011 DS0 channels
•
•
Power requirement: 0.53 A @ 48 V (25.4 W)
Model number: PB-4CHDS3-E3-IQE-BNC
• Ports are numbered 0 through 3 top to bottom
Copyright © 2018, Juniper Networks, Inc.
Chapter 5: Channelized Enhanced IQ (IQE) PIC Descriptions
Software features •
•
•
Maximum transmission units (MTUs) of up to 9000 bytes
Dynamic, arbitrary channel configuration
Subrate and scrambling:
NOTE: Only DS3 interfaces supports subrate and scrambling.
•
•
•
•
•
Digital Link/Quick Eagle
Kentrox
Larscom
ADTRAN
Verilink (subrate: only port A mode)
NOTE: For DS3 interfaces, Verilink does not function if an IQE interface is paired with an IQ interface.
•
•
•
•
•
•
•
•
•
Data service unit (DSU) functionality
B3ZS line encoding
Framing: M13, C-bit parity, framed clear channel
Full bit error rate test (BERT) for DS0, DS1, and DS3
ANSI T1.403 FDL
Internal and loop clocking for DS3 and DS1
DS3 far end alarm and control (FEAC) channel
Local line, remote line, and remote playback loopback testing for each DS3 and DS1 channels
Quality of service (QoS) per channel: weighted round-robin (WRR), random early detection
(RED), weighted random early detection (WRED)
•
•
•
Enhanced fine-grained queuing per logical interface. See the Class of Service Feature Guide for
Routing Devices and EX9200 Switches for more information about class of service features.
Simple Network Management Protocol (SNMP): DS1 MIB, DS3 MIB
Encapsulations:
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Circuit cross-connect (CCC)
Translational cross-connect (TCC)
Extended Frame Relay for CCC and TCC
Flexible Frame Relay
Frame Relay
Frame Relay for CCC
Frame Relay for TCC
Frame Relay port CCC
High-Level Data Link Control (HDLC)
HDLC framing for CCC
HDLC framing for TCC
MPLS CCC
MPLS TCC
Multilink Frame Relay (MLFR) UNI NNI (MFR FRF.16)
Point-to-Point Protocol (PPP)
PPP for CCC
PPP for TCC
Cables and connectors • Standard DS3 BNC coaxial cable interfaces
Copyright © 2018, Juniper Networks, Inc.
53
T4000 Core Router Interface Module Reference
LEDs
Alarms, errors, and events
Instrumentation
(counters)
One tricolor per port:
•
•
•
•
Off—Not enabled
Green—Online with no alarms or failures
Yellow—Online with alarms for remote failures
Red—Active with a local alarm; router has detected a failure
•
•
Alarm reporting for error statistics and failure counts
DS1 alarms:
•
•
•
Alarm indication signal (AIS)
Loss of frame (LOF)
Remote alarm indication signal (RAIS)
• DS1 error detection:
•
•
•
•
•
•
•
•
•
Bursty errored seconds (BES)
CRC errors
Errored seconds (ES)
Line errored seconds (LES)
Loss of framing seconds (LOFS)
Loss of signal seconds (LOSS)
Severely errored seconds (SES)
Severely errored framing seconds (SEFS)
Unavailable seconds (UAS)
• DS3 alarms:
•
•
•
•
Alarm indication signal (AIS)
Loss of frame (LOF)
Loss of signal (LOS)
Phase lock loop (PLL)
• DS3 error detection:
•
•
•
•
•
•
•
•
•
•
•
•
•
C-bit code violations (CCV)
C-bit errored seconds (CES)
C-bit severely errored framing seconds (CEFS)
CRC errors
Excessive zeros (EXZ)
Far-end block error (FEBE)
Far-end receive failure (FERF)
Line errored seconds (LES)
Parity bit (P-bit) code violations (PCV)
Parity bit (P-bit) errored seconds (PES)
Parity bit (P-bit) severely errored framing seconds (PSES)
Severely errored framing seconds (SEFS)
Unavailable seconds (UAS)
• Layer 2 per-queue and per-channel packet and byte counters
54 Copyright © 2018, Juniper Networks, Inc.
Chapter 5: Channelized Enhanced IQ (IQE) PIC Descriptions
Related
Documentation
• T4000 PIC Description
•
T4000 PICs Supported on page 3
Channelized E1/T1 Enhanced IQ (IQE) PIC (T4000 Router)
Software release
Description
Hardware features
Software features
• Junos OS Release12.1R2 and later (Type 1)
For information on which FPCs support this PIC, see
“T4000 PIC/FPC Compatibility” on page 8 .
•
•
•
Ten E1 or T1 ports
•
•
DS1 and E1 interfaces are selectable on a per-port granularity
E1 channelization per PIC:
10 E1 channels
310 DS0 channels
• T1 channelization per PIC:
•
•
10 T1 channels
240 DS0 channels
•
•
Power requirement: 0.52 A @ 48 V (24.73 W)
Model number: PB-10CHE1-T1-IQE-RJ48
Ports are numbered:
•
•
•
•
Top row: 0 and 1 from left to right
Second row: 2 and 3 from left to right
Third row: 3 and 4 from left to right
Bottom row: 5 and 6 from left to right
• Quality of service (QoS) per channel: weighted round-robin (WRR), random early detection
(RED), weighted random early detection (WRED)
Copyright © 2018, Juniper Networks, Inc.
55
T4000 Core Router Interface Module Reference
56
•
•
•
•
•
•
Enhanced fine-grained queuing per logical interface. See the Class of Service Feature Guide for
Routing Devices and EX9200 Switches for more information about class of service features.
Support sending and receiving in-band loopback codes in both framed and unframed mode:
Framed in-band loopback at CSU
Framed in-band loopback at Smartjack (ANSI)
Unframed in-band loopback at CSU
Unframed in-band loopback at Smartjack (ANSI)
• You can configure the following framing modes using the CLI:
•
•
T1—SF (D4/superframe), ESF (extended superframe)
E1—G704, G704–no-crc4, unframed
•
•
•
•
•
•
Packet buffering, Layer 2 parsing
Local line, remote line, and remote payload loopback testing; each channel can be looped individually and independently of other channels (DS1/E1 channels)
Simple Network Management Protocol (SNMP): T1 MIB (RFC 1406)
Dynamic, arbitrary channel configuration
Full bit error rate test (BERT)
•
Clocking: internal and loop (clock recovered from network and use for transmit). Internal timing is the default for channelized T1 ports. The external master clock can be a multiple of 2.048
MHz or 1.544 MHz for E1 or T1 operation.
Line coding:
•
•
T1—CLI configurable as AMI or B8ZS
E1—HDB3
• Encapsulations:
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Circuit cross-connect (CCC)
Translational cross-connect (TCC)
Extended Frame Relay for CCC and TCC
Flexible Frame Relay
Frame Relay
Frame Relay for CCC
Frame Relay for TCC
Frame Relay port CCC
High-Level Data Link Control (HDLC)
HDLC framing for CCC
HDLC framing for TCC
MPLS CCC
MPLS TCC
Point-to-Point Protocol (PPP)
PPP for CCC
PPP for TCC
•
•
•
•
Encapsulations available only for DS0 and DS1:
Multilink Frame Relay end-to-end (MLFR FRF.15)
Multilink Frame Relay (MLFR) UNI NNI (MFR FRF.16)
Multilink PPP (MLPPP)
• Encapsulations available only for DS1:
• PPP over Frame Relay
Copyright © 2018, Juniper Networks, Inc.
Chapter 5: Channelized Enhanced IQ (IQE) PIC Descriptions
Cables and connectors • 120-ohm RJ-48C connector (female)
LEDs
Alarms, errors, and events
One tricolor per port:
•
•
•
•
Off—Not enabled
Green—Online with no alarms or failures
Yellow—Online with alarms for remote failures
Red—Active with a local alarm; router has detected a failure
• DS1 alarms:
•
•
•
•
Alarm indication signal (AIS)
Loss of frame (LOF)
Remote alarm indication signal (RAIS)
24-hour alarm reporting history maintained for error statistics and failure counts, 15-minute intervals on all errors
• DS1 error detection:
•
•
•
•
•
•
•
•
•
Bursty errored seconds (BES)
CRC errors
Errored seconds (ES)
Line errored seconds (LES)
Loss of framing seconds (LOFS)
Loss of signal seconds (LOSS)
Severely errored seconds (SES)
Severely errored framing seconds (SEFS)
Unavailable seconds (UAS)
Instrumentation
(counters)
•
•
Layer 2 per-queue and per-channel packet and byte counters
Layer 2 per-queue and per-channel packet and byte drop counters
Related
Documentation
• T4000 PIC Description
•
T4000 PICs Supported on page 3
Copyright © 2018, Juniper Networks, Inc.
57
T4000 Core Router Interface Module Reference
Channelized OC3/STM1 Enhanced IQ (IQE) PIC with SFP (T4000 Router)
58
Software release
Description
Hardware features
Software features
• Junos OS Release 12.1R2 and later (Type 1)
For information on which FPCs support this PIC, see
“T4000 PIC/FPC Compatibility” on page 8 .
•
•
•
Two OC3 or STM1 ports
SONET or SDH is configurable on a per-port granularity
SONET channelization:
•
•
•
•
2 OC3 channels
6 DS3 channels
168 DS1 channels
1011 DS0 channels
• SDH channelization:
•
•
•
•
•
•
2 STM1 channels (non-concatenated)
6 E3 channels
126 E1 channels
6 DS3 channels (Junos OS Release 10.1 and later)
168 DS1 channels (Junos OS Release 10.1 and later)
1011 DS0 channels
•
•
Power requirement: 0.56 A @ 48 V (27.1 W)
Model number: PB-2CHOC3-STM1-IQE-SFP
• Ports are numbered 0 and 1 from left to right
•
•
•
Dynamic, arbitrary channel configuration
Quality of service (QoS) per channel: weighted round-robin (WRR), random early detection
(RED), weighted random early detection (WRED)
Enhanced fine-grained queuing per logical interface. See the Class of Service Feature Guide for
Routing Devices and EX9200 Switches for more information about class of service features.
Copyright © 2018, Juniper Networks, Inc.
Chapter 5: Channelized Enhanced IQ (IQE) PIC Descriptions
•
•
•
•
•
•
Subrate and scrambling:
Digital Link/Quick Eagle
Kentrox
Larscom
ADTRAN
Verilink
•
•
•
•
•
•
•
Packet buffering, Layer 2 parsing
M13/C-bit parity encoding
DS3 far-end alarm and control (FEAC) channel support
Local line, remote line, and remote payload loopback testing
Simple Network Management Protocol (SNMP): OC3 MIB, DS3 MIB, T1 MIB
Full bit error rate test (BERT)
Encapsulations:
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Circuit cross-connect (CCC)
Translational cross-connect (TCC)
Extended Frame Relay for CCC and TCC
Flexible Frame Relay
Frame Relay
Frame Relay for CCC
Frame Relay for TCC
Frame Relay port CCC
High-Level Data Link Control (HDLC)
HDLC framing for CCC
HDLC framing for TCC
MPLS CCC
MPLS TCC
Multilink Frame Relay (MLFR) UNI NNI (MFR FRF.16)
Point-to-Point Protocol (PPP)
PPP for CCC
PPP for TCC
• Encapsulations available only for DS1:
•
•
•
Multilink Frame Relay end-to-end (MLFR FRF.15)
Multilink PPP (MLPPP)
PPP over Frame Relay
Cables and connectors •
•
Duplex LC/PC connector (Rx and Tx)
SONET/SDH OC3/STM1 fiber-optic SFPs:
•
•
•
Multimode (model number: SFP-OC3-SR)
Intermediate reach (IR-1) (model number: SFP-OC3-IR)
Long reach (IR-1) (model number: SFP-OC3-LR)
Optical interface specifications—see
“SONET/SDH OC3/STM1 Optical Interface Specifications” on page 24
Copyright © 2018, Juniper Networks, Inc.
59
T4000 Core Router Interface Module Reference
60
LEDs
Alarms, errors, and events
One tricolor Status LED per port:
•
•
•
•
Off—Not enabled.
Green—Online with no alarms or failures.
Yellow—Online with alarms for remote failures.
Red—Active with a local alarm; router has detected a failure.
• SONET alarms:
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Alarm indication signal—line (AIS-L)
Alarm indication signal—path (AIS-P)
Bit error rate—signal degrade (BERR-SD)
Bit error rate—signal fail (BERR-SF)
Loss of clock (LOC)
Loss of frame (LOF)
Loss of light (LOL)
Loss of pointer (LOP)
Loss of signal (LOS)
Payload label mismatch (PLM-P)
Remote defect indication—line (RDI-L)
Remote defect indication—path (RDI-P)
Remote error indication (REI)
Payload unequipped (unequipped STS at path level) (UNEQ-P)
Virtual container—alarm indication signal (VAIS)
Virtual container—loss of clock (VLOC)
Virtual container—loss of pointer (VLOP)
Virtual container—mismatch (VMIS)
Virtual container—remote defect indication (VRD1)
Virtual container—unequipped (VUNEQ)
• SDH alarms:
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Administrative unit alarm indication signal (AU-AIS)
Bit error rate signal degrade (BERR-SD)
Bit error rate signal fail (BERR-SF)
Bit interleaved parity (BIP) error B1, B2, B3
Higher order path—alarm indication signal (HP-AIS)
Higher order path—far-end receive failure (HP-FERF)
Higher order path—payload label mismatch (HP-PLM)
Higher order path—loss of pointer (HP-LOP)
Higher order path—remote defect indication (HP-RDI)
Higher order path—unequipped (HP-UNEQ)
Loss of clock (LOC)
Loss of frame (LOF)
Loss of light (LOL)
Loss of signal (LOS)
Multiplex section—alarm indication signal (MS-AIS)
Multiplex section—far-end receive failure (MS-FERF)
Multiplex section—remote defect indication (MS-RDI)
Multiplex section—remote error indication (MS-REI)
Copyright © 2018, Juniper Networks, Inc.
Chapter 5: Channelized Enhanced IQ (IQE) PIC Descriptions
•
•
•
•
•
•
•
•
•
Phase lock loop (PLL)
Remote error indication (REI)
Severely errored frame (SEF)
Tributary unit—alarm indication signal (TU-AIS)
Tributary unit—loss of clock (TU-LOC)
Tributary unit—loss of pointer (TU-LOP)
Tributary unit—mismatch (TU-MIS)
Tributary unit—remote defect indication (TU-RD1)
Tributary unit—unequipped (TU-UNEQ)
• DS1 alarms:
•
•
•
Alarm indication signal (AIS)
Loss of frame (LOF)
Remote alarm indication signal (RAIS)
• DS1 error detection:
•
•
•
•
•
•
•
•
•
Bursty errored seconds (BES)
CRC errors
Errored seconds (ES)
Line errored seconds (LES)
Loss of framing seconds (LOFS)
Loss of signal seconds (LOSS)
Severely errored seconds (SES)
Severely errored framing seconds (SEFS)
Unavailable seconds (UAS)
• DS3 alarms:
•
•
•
•
Alarm indication signal (AIS)
Loss of frame (LOF)
Loss of signal (LOS)
Phase lock loop (PLL)
• DS3 error detection:
•
•
•
•
•
•
•
•
•
•
•
•
•
C-bit code violations (CCV)
C-bit errored seconds (CES)
C-bit severely errored framing seconds (CEFS)
CRC errors
Excessive zeros (EXZ)
Far-end block error (FEBE)
Far-end receive failure (FERF)
Line errored seconds (LES)
Parity bit (P-bit) code violations (PCV)
Parity bit (P-bit) errored seconds (PES)
Parity bit (P-bit) severely errored framing seconds (PSES)
Severely errored framing seconds (SEFS)
Unavailable seconds (UAS)
Copyright © 2018, Juniper Networks, Inc.
61
T4000 Core Router Interface Module Reference
Related
Documentation
• T4000 PIC Description
•
T4000 PICs Supported on page 3
Channelized OC12/STM4 Enhanced IQ (IQE) PICs with SFP (T4000 Router)
Figure 2: 1-Port IQE PIC Figure 3: 4-Port IQE PIC (Type 2)
Figure 4: 4-Port IQE PIC (Type 3)
62
•
•
•
•
Cables and Connectors on page 65
Copyright © 2018, Juniper Networks, Inc.
Chapter 5: Channelized Enhanced IQ (IQE) PIC Descriptions
•
•
Alarms, Errors, and Events on page 66
•
Instrumentation (counters) on page 68
Software Release
• Junos OS Release 12.1R2 (Type 1)
• Junos OS Release 12.2R2 (Type 2)
• Junos OS Release 13.2 (Type 3)
For information on which FPCs support these PICs, see
“T4000 PIC/FPC Compatibility” on page 8 .
Hardware Features
• Four OC12/STM4 ports
• SONET or SDH is configurable on a per-port granularity
• SONET channelization (4-port PIC):
• 4 OC12 channel
• 16 OC3 channels
• 48 DS3 channels
• 672 DS1 channels
• 974 DS0 channels
• SDH channelization (4-port PIC):
• 4 STM4 channel
• 16 STM1 channels
• 48 E3 channels
• 504 E1 channels
• 48 DS3 channels
• 672 DS1 channels
• 974 DS0 channels
• Power requirement: 1.08 A @ –48V (52 W)
• Model number (Type 1): PB-1CHOC12-STM4-IQE-SFP
• Model number (Type 2): PB-4CHOC12-STM4-IQE-SFP
• Model number (Type 3): PC-4CHOC12-STM4-IQE-SFP
• 1-port: Port is numbered 0.
• 4-port: Ports are numbered:
• Top row: 2 and 0 from left to right
Copyright © 2018, Juniper Networks, Inc.
63
T4000 Core Router Interface Module Reference
• Bottom row: 3 and 1 from left to right
Software Features
Table 43: Software Features Supported
Software Feature
T4000 First Supported
Junos OS Release
Quality of service (QoS) per channel: weighted round-robin (WRR), random early detection
(RED), weighted random early detection (WRED)
12.1R2
Enhanced fine-grained queuing per logical interface. See the Junos OS Class of Service Library for Routing Devices for more information about class of service features.
12.1R2
12.1R2
Subrate and scrambling:
•
•
•
•
•
Digital Link/Quick Eagle
Kentrox
Larscom
ADTRAN
Verilink
Packet buffering, Layer 2 parsing 12.1R2
12.1R2
M13/C-bit parity encoding
DS3 far-end alarm and control (FEAC) channel support 12.1R2
12.1R2
Local line, remote line, and remote payload loopback testing
Simple Network Management Protocol (SNMP): OC3 MIB, DS3 MIB, T1 MIB 12.1R2
Dynamic, arbitrary channel configuration
Full bit error rate test (BERT)
12.1R2
12.1R2
64 Copyright © 2018, Juniper Networks, Inc.
Chapter 5: Channelized Enhanced IQ (IQE) PIC Descriptions
Table 43: Software Features Supported (continued)
Software Feature
Encapsulations:
•
•
•
•
•
•
•
•
•
•
•
•
•
Circuit cross-connect (CCC)
Translational cross-connect (TCC)
Extended Frame Relay for CCC and TCC
Flexible Frame Relay
Frame Relay
Frame Relay for CCC
Frame Relay for TCC
Frame Relay port CCC
High-Level Data Link Control (HDLC)
HDLC framing for CCC
HDLC framing for TCC
MPLS CCC
MPLS TCC
•
•
•
•
Multilink Frame Relay (MLFR) UNI NNI (MFR FRF.16)
Point-to-Point Protocol (PPP)
PPP for CCC
PPP for TCC
Encapsulations available only for DS1:
•
•
•
Multilink Frame Relay end-to-end (MLFR FRF.15)
Multilink PPP (MLPPP)
PPP over Frame Relay
T4000 First Supported
Junos OS Release
12.1R2
12.1R2
12.1R2
Cables and Connectors
• Duplex LC connector (Rx and Tx); single-mode fiber
• SONET/SDH OC12/STM4 fiber-optic SFP transceivers:
• Short reach (model number: SFP-OC12-SR)
• Intermediate reach (IR-1) (model number: SFP-OC12-IR)
• Long reach (LR-1) (model number: SFP-OC12-LR)
Optical interface specifications—see
“SONET/SDH OC12/STM4 Optical Interface
Copyright © 2018, Juniper Networks, Inc.
65
T4000 Core Router Interface Module Reference
LEDs
Table 44: Channelized OC12/STM4 Enhanced IQ (IQE) PICs with SFP LEDs
Label Color State Description
STATUS —
Green
Yellow
Red
Off
On steadily
On steadily
On steadily
Not enabled
Online with no alarms or failures
Online with alarms for remote failures
Active with a local alarm; router has detected a failure
Alarms, Errors, and Events
• SONET alarms:
• Alarm indication signal—line (AIS-L)
• Alarm indication signal—path (AIS-P)
• Bit error rate—signal degrade (BERR-SD)
• Bit error rate—signal fail (BERR-SF)
• Loss of frame (LOF)
• Loss of light (LOL)
• Loss of pointer (LOP)
• Loss of signal (LOS)
• Payload label mismatch (PLM-P)
• Remote defect indication—line (RDI-L)
• Remote defect indication—path (RDI-P)
• Remote error indication (REI)
• Payload unequipped (unequipped STS at path level) (UNEQ-P)
• Virtual container—alarm indication signal (VAIS)
• Virtual container—loss of pointer (VLOP)
• Virtual container—mismatch (VMIS)
• Virtual container—remote defect indication (VRD1)
• Virtual container—unequipped (VUNEQ)
• SDH alarms:
• Administrative unit alarm indication signal (AU-AIS)
• Bit error rate—signal degrade (BERR-SD)
66 Copyright © 2018, Juniper Networks, Inc.
Chapter 5: Channelized Enhanced IQ (IQE) PIC Descriptions
• Bit error rate—signal fail (BERR-SF)
• Bit interleaved parity (BIP) error B1, B2, B3
• Higher order path—alarm indication signal (HP-AIS)
• Higher order path—far-end receive failure (HP-FERF)
• Higher order path—payload label mismatch (HP-PLM)
• Higher order path—loss of pointer (HP-LOP)
• Higher order path—remote defect indication (HP-RDI)
• Higher order path—unequipped (HP-UNEQ)
• Loss of frame (LOF)
• Loss of light (LOL)
• Loss of signal (LOS)
• Multiplex section—alarm indication signal (MS-AIS)
• Multiplex section—far-end receive failure (MS-FERF)
• Multiplex section—remote defect indication (MS-RDI)
• Multiplex section—remote error indication (MS-REI)
• Phase lock loop (PLL)
• Remote error indication (REI)
• Severely errored frame (SEF)
• Tributary unit—alarm indication signal (TU-AIS)
• Tributary unit—loss of pointer (TU-LOP)
• Tributary unit—mismatch (TU-MIS)
• Tributary unit—remote defect indication (TU-RD1)
• Tributary unit—unequipped (TU-UNEQ)
• DS1 alarms:
• Alarm indication signal (AIS)
• Loss of frame (LOF)
• Remote alarm indication signal (RAIS)
• DS1 error detection:
• Bursty errored seconds (BES)
• CRC errors
• Errored seconds (ES)
• Line errored seconds (LES)
• Loss of framing seconds (LOFS)
Copyright © 2018, Juniper Networks, Inc.
67
T4000 Core Router Interface Module Reference
• Severely errored seconds (SES)
• Severely errored framing seconds (SEFS)
• Unavailable seconds (UAS)
• DS3 alarms:
• Alarm indication signal (AIS)
• Loss of frame (LOF)
• Yellow alarm
• DS3 error detection:
• C-bit code violations (CCV)
• C-bit errored seconds (CES)
• C-bit severely errored framing seconds (CEFS)
• CRC errors
• Excessive zeros (EXZ)
• Far-end block error (FEBE)
• Far-end receive failure (FERF)
• Line errored seconds (LES)
• Parity bit (P-bit) code violations (PCV)
• Parity bit (P-bit) errored seconds (PES)
• Parity bit (P-bit) severely errored framing seconds (PSES)
• Severely errored framing seconds (SEFS)
• Unavailable seconds (UAS)
Instrumentation (counters)
Layer 2 per-queue and per-channel packet and byte counters
Related
Documentation
• T4000 PIC Description
•
T4000 PICs Supported on page 3
68 Copyright © 2018, Juniper Networks, Inc.
Chapter 5: Channelized Enhanced IQ (IQE) PIC Descriptions
Channelized OC48/STM16 Enhanced IQ (IQE) PIC with SFP (T4000 Router)
•
•
•
•
Cables and Connectors on page 71
•
•
Alarms, Errors, and Events on page 72
•
Instrumentation (counters) on page 74
•
PICs Supported in the Fourth Slot of T640-FPC2-E and T640-FPC2-E2 with Type 2
Software Release
Junos OS Release 12.2R2 and later (Type 2)
For information on which FPCs support this PIC, see
“T4000 PIC/FPC Compatibility” on page 8 .
Hardware Features
• One OC48/STM16 port
• SONET or SDH is configurable on a per-port granularity
• SONET channelization:
• 4 OC12 channels
• 16 OC3 channels
• 48 DS3 channels
Copyright © 2018, Juniper Networks, Inc.
69
T4000 Core Router Interface Module Reference
• 672 DS1 channels
• 975 DS0 channels
• SDH channelization:
• 4 STM4 channels
• 16 STM1 channels
• 48 E3 channels
• 504 E1 channels
• 48 DS3 channels
• 672 DS1 channels
• 975 DS0 channels
• Power requirement: 1.10 A @ 48V (53 W)
• Model number: PB-1CHOC48-STM16-IQE-SFP
• Port is numbered 0.
Software Features
Table 45: Software Features Supported
Software Feature
T4000 First Supported
Junos OS Release
Quality of service (QoS) per channel: weighted round-robin (WRR), random early detection
(RED), weighted random early detection (WRED)
12.2R2
Enhanced fine-grained queuing per logical interface. See the Junos OS Class of Service Library for Routing Devices for more information about class of service features.
12.1R2
Subrate and scrambling:
•
•
•
•
•
Digital Link/Quick Eagle
Kentrox
Larscom
ADTRAN
Verilink
Packet buffering, Layer 2 parsing
12.2R2
12.2R2
12.2R2
M13/C-bit parity encoding
DS3 far-end alarm and control (FEAC) channel support 12.2R2
Local line, remote line, and remote payload loopback testing
Simple Network Management Protocol (SNMP): OC3 MIB, DS3 MIB, T1 MIB
12.2R2
12.2R2
70 Copyright © 2018, Juniper Networks, Inc.
Chapter 5: Channelized Enhanced IQ (IQE) PIC Descriptions
Table 45: Software Features Supported (continued)
Software Feature
Dynamic, arbitrary channel configuration
Full bit error rate test (BERT)
Encapsulations:
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Circuit cross-connect (CCC)
Translational cross-connect (TCC)
Extended Frame Relay for CCC and TCC
Flexible Frame Relay
Frame Relay
Frame Relay for CCC
Frame Relay for TCC
Frame Relay port CCC
High-Level Data Link Control (HDLC)
HDLC framing for CCC
HDLC framing for TCC
MPLS CCC
MPLS TCC
Multilink Frame Relay (MLFR) UNI NNI (MFR FRF.16)
Point-to-Point Protocol (PPP)
PPP for CCC
PPP for TCC
Encapsulations available only for DS1:
•
•
•
Multilink Frame Relay end-to-end (MLFR FRF.15)
Multilink PPP (MLPPP)
PPP over Frame Relay
T4000 First Supported
Junos OS Release
12.2R2
12.2R2
12.2R2
12.2R2
Cables and Connectors
• Duplex LC connector (Rx and Tx); single-mode fiber
• SONET/SDH OC48/STM16 fiber-optic SFP transceivers:
• Short reach (SR-1) (model number: SFP-1OC48-SR)
• Intermediate reach (IR-1) (model number: SFP-1OC48-IR)
• Long reach (LR-1) (model number: SFP-1OC48-LR)
Optical interface specifications—see
“SONET/SDH OC48/STM16 Optical Interface
Copyright © 2018, Juniper Networks, Inc.
71
T4000 Core Router Interface Module Reference
LEDs
Table 46: Channelized OC48/STM16 Enhanced IQ (IQE) PIC with SFP LEDs
Label Color State Description
STATUS —
Green
Yellow
Red
Off
On steadily
On steadily
On steadily
Not enabled
Online with no alarms or failures
Online with alarms for remote failures
Active with a local alarm; router has detected a failure
Alarms, Errors, and Events
• SONET alarms:
• Alarm indication signal—line (AIS-L)
• Alarm indication signal—path (AIS-P)
• Bit error rate—signal degrade (BERR-SD)
• Bit error rate—signal fail (BERR-SF)
• Loss of frame (LOF)
• Loss of light (LOL)
• Loss of pointer (LOP)
• Loss of signal (LOS)
• Payload label mismatch (PLM-P)
• Remote defect indication—line (RDI-L)
• Remote defect indication—path (RDI-P)
• Remote error indication (REI)
• Payload unequipped (unequipped STS at path level) (UNEQ-P)
• Virtual container—alarm indication signal (VAIS)
• Virtual container—loss of pointer (VLOP)
• Virtual container—mismatch (VMIS)
• Virtual container—remote defect indication (VRD1)
• Virtual container—unequipped (VUNEQ)
• SDH alarms:
• Administrative unit alarm indication signal (AU-AIS)
• Bit error rate—signal degrade (BERR-SD)
72 Copyright © 2018, Juniper Networks, Inc.
Chapter 5: Channelized Enhanced IQ (IQE) PIC Descriptions
• Bit error rate—signal fail (BERR-SF)
• Bit interleaved parity (BIP) error B1, B2, B3
• Higher order path—alarm indication signal (HP-AIS)
• Higher order path—far-end receive failure (HP-FERF)
• Higher order path—payload label mismatch (HP-PLM)
• Higher order path—loss of pointer (HP-LOP)
• Higher order path—remote defect indication (HP-RDI)
• Higher order path—unequipped (HP-UNEQ)
• Loss of frame (LOF)
• Loss of light (LOL)
• Loss of signal (LOS)
• Multiplex section—alarm indication signal (MS-AIS)
• Multiplex section—far-end receive failure (MS-FERF)
• Multiplex section—remote defect indication (MS-RDI)
• Multiplex section—remote error indication (MS-REI)
• Phase lock loop (PLL)
• Remote error indication (REI)
• Severely errored frame (SEF)
• Tributary unit—alarm indication signal (TU-AIS)
• Tributary unit—loss of pointer (TU-LOP)
• Tributary unit—mismatch (TU-MIS)
• Tributary unit—remote defect indication (TU-RD1)
• Tributary unit—unequipped (TU-UNEQ)
• DS1 alarms:
• Alarm indication signal (AIS)
• Loss of frame (LOF)
• Remote alarm indication signal (RAIS)
• DS1 error detection:
• Bursty errored seconds (BES)
• CRC errors
• Errored seconds (ES)
• Line errored seconds (LES)
• Loss of framing seconds (LOFS)
Copyright © 2018, Juniper Networks, Inc.
73
T4000 Core Router Interface Module Reference
• Severely errored seconds (SES)
• Severely errored framing seconds (SEFS)
• Unavailable seconds (UAS)
• DS3 alarms:
• Alarm indication signal (AIS)
• Loss of frame (LOF)
• Yellow alarm
• DS3 error detection:
• C-bit code violations (CCV)
• C-bit errored seconds (CES)
• C-bit severely errored framing seconds (CEFS)
• CRC errors
• Excessive zeros (EXZ)
• Far-end block error (FEBE)
• Far-end receive failure (FERF)
• Line errored seconds (LES)
• Parity bit (P-bit) code violations (PCV)
• Parity bit (P-bit) errored seconds (PES)
• Parity bit (P-bit) severely errored framing seconds (PSES)
• Severely errored framing seconds (SEFS)
• Unavailable seconds (UAS)
Instrumentation (counters)
Layer 2 per-queue and per-channel packet and byte counters
74 Copyright © 2018, Juniper Networks, Inc.
Chapter 5: Channelized Enhanced IQ (IQE) PIC Descriptions
PICs Supported in the Fourth Slot of T640-FPC2-E and T640-FPC2-E2 with Type 2 IQE PICs
Table 47: PICs Supported in Fourth Slot of T640-FPC2-E and T640-FPC2-E2 with Type 2 IQE PICs
PIC Name PIC Model Number
Gigabit Ethernet, 2-port SFP
Gigabit Ethernet, 4-port SFP
Gigabit Ethernet IQ, 2-port SFP
SONET/SDH OC12c/STM4, 4-port with multimode transceivers installed
PB-2GE-SFP
PB-4GE-SFP
PB-2GE-SFP-QPP
PB-4OC12-SON-MM
SONET/SDH OC12c/STM4, 4-port with single-mode intermediate reach transceivers installed
PB-4OC12-SON-SMIR
SONET/SDH OC48/STM16, 1-port SFP
Tunnel Services
PB-1OC48–SON-SFP
PB-TUNNEL
Related
Documentation
• T4000 PIC Description
•
T4000 PICs Supported on page 3
Copyright © 2018, Juniper Networks, Inc.
75
T4000 Core Router Interface Module Reference
76 Copyright © 2018, Juniper Networks, Inc.
CHAPTER 6
DS3 and E3 PIC Descriptions
•
DS3/E3 Enhanced IQ (IQE) PIC (T4000 Router) on page 77
DS3/E3 Enhanced IQ (IQE) PIC (T4000 Router)
Software release
Description
Hardware features
• Junos OS Release 12.1R2 and later (Type 1)
For information on which FPCs support this PIC, see
“T4000 PIC/FPC Compatibility” on page 8 .
•
•
•
•
Four DS3 or E3 ports
DS3 or E3 is configurable on a per-port granularity
Power requirement: 0.51 A @ 48 V (24.7 W)
Model number: PB-4DS3-E3-IQE-BNC
• Ports are numbered 0 through 3 top to bottom
Copyright © 2018, Juniper Networks, Inc.
77
T4000 Core Router Interface Module Reference
Software features •
•
Maximum transmission units (MTUs) of up to 9192 bytes
Subrate and scrambling:
NOTE: Only DS3 interfaces support subrate and scrambling.
•
•
•
•
•
Digital Link/Quick Eagle
Kentrox
Larscom
ADTRAN
Verilink (subrate: only port A mode)
NOTE: For DS3 interfaces, Verilink does not function if an IQE interface is paired with an IQ interface.
•
•
•
•
•
•
•
•
•
•
Data service unit (DSU) functionality
B3ZS line encoding
Framing: M13, C-bit parity, framed clear channel
Full bit error rate test (BERT)
ANSI T1.403 FDL
Internal and loop clocking
DS3 far end alarm and control (FEAC) channel
Local line, remote line, and remote playback loopback testing
Simple Network Management Protocol (SNMP): DS3 MIB
Quality of service (QoS) per channel: weighted round-robin (WRR), random early detection
(RED), weighted random early detection (WRED)
•
•
Enhanced fine-grained queuing per logical interface. See the Class of Service Feature Guide for
Routing Devices and EX9200 Switches for more information about class of service features.
Encapsulations:
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Circuit cross-connect (CCC)
Translational cross-connect (TCC)
Extended Frame Relay for CCC and TCC
Flexible Frame Relay
Frame Relay
Frame Relay for CCC
Frame Relay for TCC
Frame Relay port CCC
High-Level Data Link Control (HDLC)
HDLC framing for CCC
HDLC framing for TCC
MPLS CCC
MPLS TCC
Multilink Frame Relay (MLFR) UNI NNI (MFR FRF.16)
Point-to-Point Protocol (PPP)
PPP for CCC
PPP for TCC
Cables and connectors • Standard DS3 BNC coaxial cable interfaces
78 Copyright © 2018, Juniper Networks, Inc.
Chapter 6: DS3 and E3 PIC Descriptions
LEDs
Alarms, errors, and events
Instrumentation
(counters)
One tricolor per port:
•
•
•
•
Off—Not enabled
Green—Online with no alarms or failures
Yellow—Online with alarms for remote failures
Red—Active with a local alarm; router has detected a failure
• DS3 alarms:
•
•
•
•
Alarm indication signal (AIS)
Loss of frame (LOF)
Loss of signal (LOS)
Phase lock loop (PLL)
• DS3 error detection:
•
•
•
•
•
•
•
•
•
•
•
•
•
C-bit code violations (CCV)
C-bit errored seconds (CES)
C-bit severely errored framing seconds (CEFS)
CRC errors
Excessive zeros (EXZ)
Far-end block error (FEBE)
Far-end receive failure (FERF)
Line errored seconds (LES)
Parity bit (P-bit) code violations (PCV)
Parity bit (P-bit) errored seconds (PES)
Parity bit (P-bit) severely errored framing seconds (PSES)
Severely errored framing seconds (SEFS)
Unavailable seconds (UAS)
• Layer 2 per-queue and per-channel packet and byte counters
Related
Documentation
• T4000 PIC Description
•
T4000 PICs Supported on page 3
Copyright © 2018, Juniper Networks, Inc.
79
T4000 Core Router Interface Module Reference
80 Copyright © 2018, Juniper Networks, Inc.
CHAPTER 7
Fast Ethernet PIC Descriptions
•
Fast Ethernet PIC (T4000 Router) on page 81
Fast Ethernet PIC (T4000 Router)
Software release
Description
Hardware features
Software features
• Junos OS Release 12.1R2 and later (Type 1)
For information on which FPCs support this PIC, see
“T4000 PIC/FPC Compatibility” on page 8 .
•
•
•
4 100Base-TX ports
Power requirement: 0.14 A @ 48 V (6.8 W)
Model number: PB-4FE-TX
•
•
•
•
•
•
High-performance throughput on each port at speeds up to 100 Mbps
Source and destination Media Access Control (MAC) address filtering
RMON EtherStats packet buffering
802.3 Ethernet standard compliant
MTUs up to 1533 bytes
1,024 autosensing 802.1q VLANs per port
•
•
•
•
Autosensing full-duplex and half-duplex modes
Virtual Router Redundancy Protocol (VRRP)
802.1q virtual LANs (VLANs)
Circuit cross-connect (CCC) VLAN
Copyright © 2018, Juniper Networks, Inc.
81
T4000 Core Router Interface Module Reference
Cables and connectors 4-port PIC:
• Connector: Two-pair, Category 5 unshielded twisted-pair connectivity through an RJ-45 connector
• Pinout: MDI noncrossover
LEDs Status LED, one bicolor:
•
•
•
Off—PIC ports not enabled.
Green—PIC is operating normally.
Red—PIC has an error or failure.
4-port PIC—One pair of port LEDs:
•
•
Link LED—If green, the port is online; if there is no light, the port is down.
RX LED—If flashing green, the port is receiving data; if there is no light, the port might be on but is not receiving data.
Related
Documentation
• T4000 PIC Description
•
T4000 PICs Supported on page 3
82 Copyright © 2018, Juniper Networks, Inc.
CHAPTER 8
Gigabit Ethernet PIC Descriptions
•
Gigabit Ethernet PICs with SFP (T4000 Router) on page 83
•
Gigabit Ethernet IQ PIC with SFP (T4000 Router) on page 86
•
Gigabit Ethernet IQ2 PICs with SFP (T4000 Router) on page 89
•
Gigabit Ethernet Enhanced IQ2 (IQ2E) PIC with SFP (T4000 Router) on page 92
Gigabit Ethernet PICs with SFP (T4000 Router)
Figure 5: 2-Port Gigabit Ethernet PIC Figure 6: 4-Port Gigabit Ethernet PIC
•
•
•
•
Cables and Connectors on page 85
•
Copyright © 2018, Juniper Networks, Inc.
83
T4000 Core Router Interface Module Reference
Software Release
• 2-port: Junos OS Release 12.2R2 and later (Type 2)
• 4-port: Junos OS Release 12.2R2 and later (Type 2)
• 10-port: Junos OS Release 12.1R2 and later (Type 3)
For information on which FPCs support this PIC, see
“T4000 PIC/FPC Compatibility” on page 8 .
Hardware Features
• Ten Gigabit Ethernet ports
• Power requirement: 0.62 A @ 48 V (29.9 W)
• Supports large Ethernet frame sizes for more efficient throughput across the intra-POP network
• Model number for 2-Port Gigabit Ethernet PIC: PB-2GE-SFP
• Model number for 4-Port Gigabit Ethernet PIC: PB-4GE-SFP
• Model number for 10-Port Gigabit Ethernet PIC: PC-10GE-SFP
• High-performance throughput on each port at speeds up to 1 Gbps
• Autonegotiation between Gigabit Ethernet circuit partners
• Full-duplex mode
• Maximum transmission units (MTUs) of up to 9192 bytes
Software Features
Table 48: Software Features Supported
Software Feature
Virtual Router Redundancy Protocol (VRRP) support
802.1q virtual LANs (VLANs) support
960 destination MAC filters per port
Optical diagnostics and related alarms
Passive monitoring for IPv4 packets
T4000 First Supported Junos OS Release
12.2R2
12.2R2
12.2R2
12.2R2
12.2R2
84 Copyright © 2018, Juniper Networks, Inc.
Chapter 8: Gigabit Ethernet PIC Descriptions
NOTE: The 10-port Gigabit Ethernet PIC with SFP does not support MAC accounting and policing, MAC learning, TPID, or flexible Ethernet encapsulation.
The 10-port Gigabit Ethernet PIC supports 64 source MAC filters per port.
Cables and Connectors
• You can install any transceiver supported by the PIC.
• Fiber-optic SFP transceivers:
• Duplex LC/PC connector (Rx and Tx)
• 1000BASE-LH (model number: SFP-1GE-LH)
• 1000BASE-LX (model number: SFP-1GE-LX)
• 1000BASE-SX (model number: SFP-1GE-SX)
• Optical interface specifications—see the Hardware Compatibility Tool at https://apps.juniper.net/hct/
• 1000BASE-BX (model number pairs: SFP-GE10KT13R14 with SFP-GE10KT14R13,
SFP-GE10KT13R15 with SFP-GE10KT15R13, SFP-GE40KT13R15 with
SFP-GE40KT15R13)—see the Hardware Compatibility Tool at https://apps.juniper.net/hct/
• Copper transceiver:
• Connector: Four-pair, Category 5 shielded twisted-pair connectivity through an RJ-45 connector
• 1000BASE-T (model number: SFP-1GE-T)
• Pinout: MDI crossover
• Copper interface specifications—see the Hardware Compatibility Tool at https://apps.juniper.net/hct/
NOTE: Do not install Gigabit Ethernet SFPs in the SONET/SDH port. The port will not recognize the SFP.
Copyright © 2018, Juniper Networks, Inc.
85
T4000 Core Router Interface Module Reference
LEDs
Table 49: Gigabit Ethernet PICs with SFP LEDs
Label Color State
STATUS —
Green
Red
LINK for each port Green
—
ACT for each port Green
—
Off
On steadily
On steadily
On steadily
Off
Flashing
Off
Related
Documentation
• T4000 PIC Description
•
T4000 PICs Supported on page 3
Gigabit Ethernet IQ PIC with SFP (T4000 Router)
Figure 7: 2-Port Gigabit Ethernet IQ PIC
Description
PIC is not enabled.
PIC is operating normally.
PIC has an error or failure.
The port is online.
The port is down.
The port is receiving data.
The port might be on but is not receiving data.
86
•
•
•
•
Cables and Connectors on page 87
•
Gigabit Ethernet IQ PIC with SFP LEDs on page 88
Copyright © 2018, Juniper Networks, Inc.
Chapter 8: Gigabit Ethernet PIC Descriptions
Software Release
2-port: Junos OS Release 12.2R2 and later (Type 2):
For information on which FPCs support this PIC, see
“T4000 PIC/FPC Compatibility” on page 8 .
Hardware Features
• Two Gigabit Ethernet ports
• Power requirement: 0.46 A @ 48 V (22 W)
• Fine-grained queuing per logical interface
• Model number: PB-2GE-SFP-QPP
• High-performance throughput on each port at speeds up to 1 Gbps
• Full-duplex mode
• Large MTUs of up to 9192 bytes
Software Features
Table 50: Software Features Supported
Software Feature
Optical diagnostics and related alarms
Quality of service (QoS) per channel: weighted round-robin (WRR), random early detection (RED), weighted random early detection (WRED)
Virtual Router Redundancy Protocol (VRRP) support
802.1q virtual LANs (VLANs)
VLAN stacking and rewriting
Flexible Ethernet encapsulation
MAC policing, accounts, and filters
T4000 First Supported Junos OS
Release
12.2R2
12.2R2
12.2R2
12.2R2
12.2R2
12.2R2
12.2R2
Cables and Connectors
• You can install any transceiver supported by the PIC.
• Fiber-optic small form-factor pluggable (SFP) transceivers:
• Duplex LC connector (Rx and Tx)
• 1000BASE-LH (model number: SFP-1GE-LH)
• 1000BASE-LX (model number: SFP-1GE-LX)
Copyright © 2018, Juniper Networks, Inc.
87
T4000 Core Router Interface Module Reference
• 1000BASE-SX (model number: SFP-1GE-SX)
• Optical interface specifications—see the Hardware Compatibility Tool at https://apps.juniper.net/hct/
• 1000BASE-BX (model number pairs: SFP-GE10KT13R14 with SFP-GE10KT14R13,
SFP-GE10KT13R15 with SFP-GE10KT15R13, SFP-GE40KT13R15 with
SFP-GE40KT15R13)—see the Hardware Compatibility Tool at https://apps.juniper.net/hct/
• Copper transceiver:
• Connector: Four-pair, Category 5 shielded twisted-pair connectivity through an RJ-45 connector
• 1000BASE-T (model number: SFP-1GE-T)
• Pinout: MDI crossover
• Copper interface specifications—see the Hardware Compatibility Tool at https://apps.juniper.net/hct/
NOTE: Do not install SONET/SDH OC48c/STM16 SFPs in a Gigabit Ethernet port. The port will not recognize the SFP.
Gigabit Ethernet IQ PIC with SFP LEDs
Table 51: LEDs
Label Color State
STATUS
LINK one per port
—
Green
—
Green
Off
On steadily
Off
On steadily
ACTIVITY one per port
—
Green
Off
On steadily
Description
PIC is not enabled.
At least one port is online.
Port is down.
Link is established.
No activity.
Link has activity.
Related
Documentation
• T4000 PIC Description
•
T4000 PICs Supported on page 3
88 Copyright © 2018, Juniper Networks, Inc.
Chapter 8: Gigabit Ethernet PIC Descriptions
Gigabit Ethernet IQ2 PICs with SFP (T4000 Router)
Figure 8: 4-Port Gigabit Ethernet IQ2 PIC (Type 1) Figure 9: 8-Port Gigabit Ethernet IQ2 PIC (Type 2)
•
•
•
•
Cables and Connectors on page 90
•
Software Release
• 4-port: Junos OS Release 12.1R2 and later (Type 1)
• 8-port: Junos OS Release 12.2R2 and later (Type 2)
• 8-port: Junos OS Release 12.1R2 and later (Type 3)
For information on which FPCs support this PIC, see
“T4000 PIC/FPC Compatibility” on page 8 .
Hardware Features
• Eight Gigabit Ethernet ports
• Power requirement: 1.25 A @48 V (60 W)
• Model number for 4-Port Gigabit Ethernet IQ2 PIC: PB-4GE-TYPE1-SFP-IQ2
• Model number for 8-port Type 2 Gigabit Ethernet IQ2 PIC: PB-8GE-TYPE2-SFP-IQ2
• Model number for 8-port Type 3 Gigabit Ethernet IQ2 PIC: PC-8GE-TYPE3-SFP-IQ2
• High-performance throughput: speeds up to 1 Gbps on each port
Copyright © 2018, Juniper Networks, Inc.
89
T4000 Core Router Interface Module Reference
• Full-duplex mode
• Large maximum transmission units (MTUs) of up to 9192 bytes
Software Features
Table 52: Software Features Supported
Software Feature
T4000 First Supported Junos OS
Release
Optical diagnostics and related alarms 12.1R2
Quality of service (QoS) per channel: weighted round-robin (WRR), random early detection
(RED), weighted random early detection (WRED)
12.1R2
Virtual Router Redundancy Protocol (VRRP) support
Hierarchical shaping
Fine-grained queuing and shaping per logical interface at both ingress and egress
802.1q virtual LANs (VLANs)
VLAN stacking and rewriting
Channels defined by two stacked VLAN tags
Multiple tag protocol identifiers (TPID) support
IP service for nonstandard TPID and stacked VLAN tags
802.1p rewrite per channel
Flexible mapping of channels and scheduler resources at both ingress and egress
Flexible Ethernet encapsulation
MAC learning, policing, accounting, and filtering
12.1R2
12.1R2
12.1R2
12.1R2
12.1R2
12.1R2
12.1R2
12.1R2
12.1R2
12.1R2
12.1R2
12.1R2
Cables and Connectors
• You can install any transceiver supported by the PIC.
NOTE: Do not install SONET/SDH SFPs in the Gigabit Ethernet port. The port will not recognize the SFP.
• Fiber-optic SFP transceivers:
90 Copyright © 2018, Juniper Networks, Inc.
Chapter 8: Gigabit Ethernet PIC Descriptions
• Duplex LC connector (Rx and Tx)
• 1000BASE-LH (model number: SFP-1GE-LH)
• 1000BASE-LX (model number: SFP-1GE-LX)
• 1000BASE-SX (model number: SFP-1GE-SX)
• Optical interface specifications—see the Hardware Compatibility Tool at https://apps.juniper.net/hct/
• 1000BASE-BX (model number pairs: SFP-GE10KT13R14 with SFP-GE10KT14R13,
SFP-GE10KT13R15 with SFP-GE10KT15R13, SFP-GE40KT13R15 with
SFP-GE40KT15R13)—see the Hardware Compatibility Tool at https://apps.juniper.net/hct/
• Copper transceiver:
• Connector: Four-pair, Category 5 shielded twisted-pair connectivity through an RJ-45 connector
• 1000BASE-T (model number: SFP-1GE-T)
• Pinout: MDI crossover
• Copper interface specifications—see the Hardware Compatibility Tool at https://apps.juniper.net/hct/
LEDs
Table 53: Gigabit Ethernet IQ2 PICs with SFP LEDs
Label Color State
OK or Status
LED, one tricolor
—
Green
Yellow
Red
Off
On steadily
On steadily
On steadily
Description
PIC is offline and it is safe to remove it from the router.
PIC is operating normally.
PIC is initializing.
PIC has an error or failure.
Related
Documentation
• T4000 PIC Description
•
T4000 PICs Supported on page 3
Copyright © 2018, Juniper Networks, Inc.
91
T4000 Core Router Interface Module Reference
Gigabit Ethernet Enhanced IQ2 (IQ2E) PIC with SFP (T4000 Router)
Figure 10: 8-Port Gigabit Ethernet IQ2E PIC (Type 3)
•
•
•
•
Cables and Connectors on page 94
•
Software Release
8-port: Junos OS Release 12.1R2 and later (Type 3)
For information on which FPCs support this PIC, see
“T4000 PIC/FPC Compatibility” on page 8 .
Hardware Features
• Eight Gigabit Ethernet ports
• Power requirement:
• 8-port (Type 3): 1.25 A @48 V (60 W)
• Model number: PC-8GE-TYPE3-SFP-IQ2E
• High-performance throughput: speeds up to 1 Gbps on each port
• Full-duplex mode
• Large maximum transmission units (MTUs) of up to 9192 bytes
92 Copyright © 2018, Juniper Networks, Inc.
Chapter 8: Gigabit Ethernet PIC Descriptions
Software Features
Table 54: Software Features Supported
Software Feature
T4000 First Supported Junos
OS Release
Optical diagnostics and related alarms 12.1R2
Quality of service (QoS) per channel: weighted round-robin (WRR), random early detection
(RED), weighted random early detection (WRED)
12.1R2
Drop statistics reported per queue for each of four priority-based drop profiles
Four levels of strict priorities with priority propagation among scheduling levels
Hierarchical shaping and hierarchical scheduler
12.1R2
12.1R2
12.1R2
Virtual Router Redundancy Protocol (VRRP) support
Fine-grained queuing and shaping per logical interface at both ingress and egress
802.1q virtual LANs (VLANs)
VLAN stacking and rewriting
Channels defined by two stacked VLAN tags
Multiple tag protocol identifiers (TPID) support
IP service for nonstandard TPID and stacked VLAN tags
802.1p rewrite per channel
Flexible mapping of channels and scheduler resources at both ingress and egress
12.1R2
12.1R2
12.1R2
12.1R2
16,000 schedulers (2,000 schedulers with 8 queues each or 4,000 schedulers with 4 queues each)
12.1R2
Scheduler resources dynamically allocated across ports 12.1R2
Flexible Ethernet encapsulation
MAC learning, policing, accounting, and filtering
12.1R2
12.1R2
12.1R2
12.1R2
12.1R2
12.1R2
12.1R2
Copyright © 2018, Juniper Networks, Inc.
93
T4000 Core Router Interface Module Reference
Cables and Connectors
• You can install any transceiver supported by the PIC.
NOTE: Do not install SONET/SDH SFPs in the Gigabit Ethernet port. The port will not recognize the SFP.
• Fiber-optic small form-factor pluggable transceivers (SFPs):
• Duplex LC connector (Rx and Tx)
• Small form-factor pluggable (SFP) transceivers:
• 1000BASE-LH (model number: SFP-1GE-LH)
• 1000BASE-LX (model number: SFP-1GE-LX)
• 1000BASE-SX (model number: SFP-1GE-SX)
• Optical interface specifications—see the Hardware Compatibility Tool at https://apps.juniper.net/hct/
• 1000BASE-BX (model number pairs: SFP-GE10KT13R14 with SFP-GE10KT14R13,
SFP-GE10KT13R15 with SFP-GE10KT15R13, SFP-GE40KT13R15 with
SFP-GE40KT15R13)—see the Hardware Compatibility Tool at https://apps.juniper.net/hct/
• Copper transceiver:
• Connector: Four-pair, Category 5 shielded twisted-pair connectivity through an RJ-45 connector
• 1000BASE-T (model number: SFP-1GE-T)
• Pinout: MDI crossover
Copper interface specifications—see the Hardware Compatibility Tool at https://apps.juniper.net/hct/
LEDs
Table 55: Gigabit Ethernet Enhanced IQ2 (IQ2E) PIC with SFP LEDs
Label Color State Description
OK or Status LED, one tricolor
— Off PIC is offline and it is safe to remove it from the router.
Green
Yellow
Red
On steadily
On steadily
On steadily
PIC is operating normally.
PIC is initializing.
PIC has an error or failure.
94 Copyright © 2018, Juniper Networks, Inc.
Chapter 8: Gigabit Ethernet PIC Descriptions
Table 55: Gigabit Ethernet Enhanced IQ2 (IQ2E) PIC with SFP LEDs (continued)
Label Color State Description
APP LED, one bicolor
—
Green
Port LEDs, labeled
0 through 9 , one per port
—
Green
Off
On steadily
Off
On steadily
Monitoring application is not running.
Monitoring application is running under acceptable load.
Port is not enabled.
Port is online with no alarms or failures.
Related
Documentation
• T4000 PIC Description
•
T4000 PICs Supported on page 3
Copyright © 2018, Juniper Networks, Inc.
95
T4000 Core Router Interface Module Reference
96 Copyright © 2018, Juniper Networks, Inc.
CHAPTER 9
10-Gigabit Ethernet PIC Descriptions
•
10-Gigabit Ethernet PIC with XENPAK (T4000 Router) on page 97
•
10-Gigabit Ethernet IQ2 PIC with XFP (T4000 Router) on page 100
•
10-Gigabit Ethernet IQ2E PIC with XFP (T4000 Router) on page 103
•
10-Gigabit Ethernet LAN/WAN PIC with SFP+ (T4000 Router) on page 106
•
10-Gigabit Ethernet LAN/WAN PIC with Oversubscription and SFP+ (T4000
•
10-Gigabit Ethernet LAN/WAN PIC with XFP (T4000 Router) on page 117
10-Gigabit Ethernet PIC with XENPAK (T4000 Router)
•
•
•
•
Cables and Connectors on page 98
•
Copyright © 2018, Juniper Networks, Inc.
97
T4000 Core Router Interface Module Reference
Software Release
Junos OS Release 12.2R2 and later (Type 3)
For information on which FPCs support this PIC, see
“T4000 PIC/FPC Compatibility” on page 8 .
Hardware Features
• One 10-Gigabit Ethernet port
• Power requirement: 0.55 A @ 48 V (26.6 W)
• Supports large Ethernet frame sizes for more efficient throughput across the intra-POP network
• Model number: PC-1XGE-XENPAK
• High-performance throughput at speeds up to 10 Gbps
• Full-duplex mode
• Maximum transmission units (MTUs) up to 9192 bytes
• 64 source MAC address filters
• 960 destination MAC filters
Software Features
Table 56: Software Features Supported
Software Feature
Virtual Router Redundancy Protocol (VRRP) support
802.1q virtual LANs (VLANs) support
IEEE 802.3ad Link Aggregation
RMON EtherStats
Optical diagnostics and related alarms :
•
•
•
•
Transceiver temperature
Laser bias current
Laser output power
Receive optical power
T4000 First Supported Junos OS
Release
12.2R2
12.2R2
12.2R2
12.2R2
12.2R2
Cables and Connectors
• Duplex SC connector (RX and TX)
• 10-Gigabit Ethernet XENPAK transceivers:
98 Copyright © 2018, Juniper Networks, Inc.
Chapter 9: 10-Gigabit Ethernet PIC Descriptions
• 10GBASE-SR, LAN Rate (model number: XENPAK-1XGE-SR)
• 10GBASE-LR, LAN Rate (model number: XENPAK-1XGE-LR)
• 10GBASE-ER, LAN Rate (model number: XENPAK-1XGE-ER)
• 10GBASE-ZR, LAN Rate (model number: XENPAK-1XGE-ZR) EOL (see
PSN-2010-02-649 )
Optical interface specifications—see the Hardware Compatibility Tool at https://apps.juniper.net/hct/
LEDs
Table 57: 10-Gigabit Ethernet PIC with XENPAK LEDs
Label Color State
STATUS
Port LED LINK
—
Green
Red
—
Green
Off
On steadily
On steadily
Off
On steadily
Port LED Rx —
Green
Off
On steadily
Description
PIC is not enabled.
PIC is operating normally.
PIC has an error or failure.
The port is down.
The port is online.
The port might be on but is not receiving data.
The port is receiving data.
Related
Documentation
• T4000 PIC Description
•
T4000 PICs Supported on page 3
Copyright © 2018, Juniper Networks, Inc.
99
T4000 Core Router Interface Module Reference
10-Gigabit Ethernet IQ2 PIC with XFP (T4000 Router)
•
•
•
•
Cables and Connectors on page 101
•
Software Release
Junos OS Release 12.1R2 and later (Type 3)
For information on which FPCs support this PIC, see
“T4000 PIC/FPC Compatibility” on page 8 .
Hardware Features
• One 10-Gigabit Ethernet port
• Power requirements: 1.2 A @48 V (56 W)
• Model number: PC-1XGE-TYPE3-XFP-IQ2
• High-performance throughput
• WAN-PHY mode at 9.953 Gbps
• LAN-PHY mode at 10.3125 Gbps
• Full-duplex mode
• Large maximum transmission units (MTUs) of up to 9192 bytes
100 Copyright © 2018, Juniper Networks, Inc.
Chapter 9: 10-Gigabit Ethernet PIC Descriptions
Software Features
Table 58: Software Features Supported
Software Feature
T4000 First Supported Junos OS
Release
Quality of service (QoS) per channel: weighted round-robin (WRR), random early detection
(RED), weighted random early detection (WRED)
12.1R2
12.1R2
Configurable WAN-PHY mode options:
•
•
•
• loopback mpls path-trace trigger
Virtual Router Redundancy Protocol (VRRP) support 12.1R2
12.1R2
Hierarchical shaping
Fine-grained queuing and shaping per logical interface at both ingress and egress 12.1R2
802.1q virtual LANs (VLANs)
VLAN stacking and rewriting
Channels defined by two stacked VLAN tags
Multiple tag protocol identifiers (TPID) support
IP service for nonstandard TPID and stacked VLAN tags
802.1p rewrite per channel
Flexible mapping of channels and scheduler resources at both ingress and egress
Flexible Ethernet encapsulation
MAC learning, policing, accounting, and filtering
12.1R2
12.1R2
12.1R2
12.1R2
12.1R2
12.1R2
12.1R2
12.1R2
12.1R2
Cables and Connectors
• You can install any transceiver supported by the PIC.
• Fiber-optic 10-Gigabit small form-factor pluggable (XFP) transceivers:
• Duplex LC connector (Rx and Tx)
• 10-Gigabit Ethernet XFP transceivers:
Copyright © 2018, Juniper Networks, Inc.
101
T4000 Core Router Interface Module Reference
• 10GBASE-S (model number: XFP-10G-S)
• 10GBASE-L (model number: XFP-10G-L-OC192-SR1)
• 10GBASE-E (model number: XFP-10G-E-OC192-IR2)
• 10GBASE-Z (model number: XFP-10G-Z-OC192-LR2)
Optical interface specifications—see the Hardware Compatibility Tool at https://apps.juniper.net/hct/
LEDs
Table 59: 10-Gigabit Ethernet IQ2 PIC with XFP LEDs
Label Color State
OK LED, one tricolor
—
Green
Yellow
Red
Off
On steadily
On steadily
On steadily
APP LED —
Yellow
Green
LINK STATUS
LED
—
Green
Off
On steadily
On steadily
Off
On steadily
Description
PIC is offline and safe to remove from the router.
PIC is operating normally.
PIC is initializing.
PIC has an error or failure.
Monitoring application is not running.
Monitoring application is overloaded.
Monitoring application is running under acceptable load.
Port is down.
Port is online. Link is established.
Related
Documentation
• T4000 PIC Description
•
T4000 PICs Supported on page 3
102 Copyright © 2018, Juniper Networks, Inc.
10-Gigabit Ethernet IQ2E PIC with XFP (T4000 Router)
Chapter 9: 10-Gigabit Ethernet PIC Descriptions
•
•
•
•
Cables and Connectors on page 105
•
Software Release
Junos OS Release 12.1R2 and later (Type 3)
For information on which FPCs support this PIC, see
“T4000 PIC/FPC Compatibility” on page 8 .
Hardware Features
• One 10-Gigabit Ethernet port
• Power requirements: 1.2 A @48 V (56 W)
• Model number: PC-1XGE-TYPE3-XFP-IQ2E
• High-performance throughput
• WAN-PHY mode at 9.953 Gbps
• LAN-PHY mode at 10.3125 Gbps
• Full-duplex mode
• Large maximum transmission units (MTUs) of up to 9192 bytes
Copyright © 2018, Juniper Networks, Inc.
103
T4000 Core Router Interface Module Reference
Software Features
Table 60: Software Features Supported
Software Feature
T4000 First Supported Junos
OS Release
Quality of service (QoS) per channel: weighted round-robin (WRR), random early detection
(RED), weighted random early detection (WRED)
12.1R2
Drop statistics reported per queue for each of four priority-based drop profiles
Four levels of strict priorities with priority propagation among scheduling levels
12.1R2
12.1R2
Hierarchical shaping and hierarchical scheduler
Configurable WAN-PHY mode options:
•
•
•
• loopback mpls path-trace trigger
Virtual Router Redundancy Protocol (VRRP) support
12.1R2
12.1R2
Fine-grained queueing and shaping per logical interface at both ingress and egress
802.1q virtual LANs (VLANs)
VLAN stacking and rewriting
Channels defined by two stacked VLAN tags
12.1R2
12.1R2
12.1R2
12.1R2
12.1R2
Multiple tag protocol identifiers (TPID) support
IP service for nonstandard TPID and stacked VLAN tags
802.1p rewrite per channel
Flexible mapping of channels and scheduler resources at both ingress and egress
12.1R2
12.1R2
12.1R2
12.1R2
16,000 schedulers (2,000 schedulers with 8 queues each or 4,000 schedulers with 4 queues each)
12.1R2
Scheduler resources dynamically allocated across ports 12.1R2
Flexible Ethernet encapsulation
MAC learning, policing, accounting, and filtering
12.1R2
12.1R2
104 Copyright © 2018, Juniper Networks, Inc.
Chapter 9: 10-Gigabit Ethernet PIC Descriptions
Cables and Connectors
• You can install any transceiver supported by the PIC.
• Fiber-optic 10-Gigabit small form-factor pluggable (XFP) transceivers:
• Duplex LC connector (Rx and Tx)
• 10-Gigabit Ethernet XFP transceivers:
• 10GBASE-S (model number: XFP-10G-S)
• 10GBASE-L (model number: XFP-10G-L-OC192-SR1)
• 10GBASE-E (model number: XFP-10G-E-OC192-IR2)
• 10GBASE-Z (model number: XFP-10G-Z-OC192-LR2)
Optical interface specifications—see the Hardware Compatibility Tool at https://apps.juniper.net/hct/
LEDs
Table 61: 10-Gigabit Ethernet IQ2E PIC with XFP LEDs
Label Color State
OK LED, one tricolor
—
Green
Yellow
Red
Off
On steadily
On steadily
On steadily
APP LED —
Yellow
Green
LINK STATUS
LED
—
Green
Off
On steadily
On steadily
Off
On steadily
Description
PIC is offline and safe to remove from the router.
PIC is operating normally.
PIC is initializing.
PIC has an error or failure.
Monitoring application is not running.
Monitoring application is overloaded.
Monitoring application is running under acceptable load.
Port is down.
Port is online. Link is established.
Related
Documentation
• T4000 PIC Description
•
T4000 PICs Supported on page 3
Copyright © 2018, Juniper Networks, Inc.
105
T4000 Core Router Interface Module Reference
10-Gigabit Ethernet LAN/WAN PIC with SFP+ (T4000 Router)
•
•
•
•
Cables and Connectors on page 108
•
•
Software Release
Junos OS Release 12.1 and later (Type 5)
For information about which FPCs support these PICs, see
“T4000 PIC/FPC Compatibility” on page 8 .
Hardware Features
• Twelve 10-Gigabit Ethernet SFP+ ports
• Power requirements: 0.69 A @48 V (33 W)
106 Copyright © 2018, Juniper Networks, Inc.
Chapter 9: 10-Gigabit Ethernet PIC Descriptions
• Model number: PF-12XGE-SFPP
• ONLINE/OFFLINE button
• Large maximum transmission units (MTUs) of up to 9192 bytes
Software Features
Table 62: Software Features Supported
Software Feature
LAN-PHY mode selectable per port
WAN-PHY mode selectable per port
Interface hold timer
SNMP support to access all 10 Gigabit Ethernet port counters
Graceful Routing Engine switchover (GRES) support
Layer 2 protocols:
•
•
•
•
•
•
•
•
Flexible Ethernet service
Ethernet circuit cross-connect (CCC)
Ethernet translational Ethernet circuit cross-connect (TCC)
Ethernet VPLS
VLAN CCC
Extended VLAN CCC
Extended VLAN TCC
VLAN VPLS
Layer 3 protocols:
•
•
•
IPv4
IPv6
MPLS
MAC filtering, accounting, policing, and learning for source media access control (MAC) on logical interfaces
Flexible encapsulation
Single, stacked, and flexible VLAN tagging modes
Native VLAN configuration to allow untagged frames to be received on the tagged interfaces
IEEE 802.3ad link aggregation (on single chassis)
12.1R1
12.1R1
12.1R1
12.1R1
T4000 First Supported
Junos OS Release
12.1R1
12.1R2
12.1R1
12.1R1
12.1R2
12.1R1
12.1R1
12.1R2
Copyright © 2018, Juniper Networks, Inc.
107
T4000 Core Router Interface Module Reference
Table 62: Software Features Supported (continued)
Software Feature
T4000 First Supported
Junos OS Release
Defining the VLAN rewrite operation to be applied to the incoming and outgoing frames on logical interfaces on this PIC.
NOTE: Only the Tag Protocol Identifier (TPID) 0x8100 is supported.
12.1R1
Interoperability with other 10-Gigabit Ethernet PICs on M Series and T Series routers in LAN-PHY and WAN-PHY modes.
12.1R1
Behavior aggregate (BA) classification (IPv4 DSCP, IPv6 DSCP, Inet precedence, IEEE 802.1P,
IEEE 802.1AD, MPLS EXP) and fixed classification.
Support for mixed-mode configuration for dual rate of 1 Gbps or 10 Gbps.
12.1R1
13.3R1
Cables and Connectors
You can install any transceiver supported by the PIC.
• Duplex LC connector (Rx and Tx)
• Fiber-optic 10-Gigabit small form-factor pluggable (SFP+) transceivers
NOTE: For configuring 1-Gbps speed, SFP optics is required; SFPP does not support 1 Gbps.
• 10GBASE-SR (model number: SFPP-10GE-SR)
• 10GBASE-LR (model number: SFPP-10GE-LR)
• 10GBASE-ER (model number: SFPP-10GE-ER): Junos OS Release 12.1R2 and later
• 10GBASE-ZR (model number: SFPP-10GE-ZR): Junos OS Release 12.3 and later
• 10GBASE-ZR (model number: SFPP-10G-OTN-XT)
• Supported in Junos OS Release 12.3R5, 13.2R3, 13.3, and later
• NEBS compliant
• Dual-rate extended temperature transceiver that supports LAN-PHY and WAN-PHY modes, and OTN rates
Optical interface specifications—see the Hardware Compatibility Tool at https://apps.juniper.net/hct/
108 Copyright © 2018, Juniper Networks, Inc.
Chapter 9: 10-Gigabit Ethernet PIC Descriptions
LEDs
Table 63: 10-Gigabit Ethernet LAN/WAN PIC with SFP+ LEDs
Label Color State
STATUS —
Green
Yellow
Red
Off
On steadily
On steadily
On steadily
Description
PIC is powered down and offline.
PIC is online with all voltages in range.
PIC is initializing.
PIC has an error or failure.
Alarms
Alarms are vendor-specific. Some transceiver vendors might not support every alarm.
• Input laser power
• Input loss of lock
• Input loss of signal
• Input Rx path
• Output A/D data not ready
• Output CDR (clock data recovery)
• Output laser bias current
• Output laser power
• Output laser safety
• Output Tx path
• Module temperature
• Module MOD_NR (module not ready)
• Module P_DOWN (module down)
• Module unplugged or down
• Wire unplugged or down
Related
Documentation
• T4000 PIC Description
•
T4000 PICs Supported on page 3
Copyright © 2018, Juniper Networks, Inc.
109
T4000 Core Router Interface Module Reference
10-Gigabit Ethernet LAN/WAN PIC with Oversubscription and SFP+ (T4000 Router)
Figure 11: 10-Port Type 4 PIC with Oversubscription
PRIMARY
Figure 12: 24-Port Type 5 PIC with Oversubscription
12
14
16
18
20
22
4
6
8
10
24 PORT ETHERNET
10GBASE-SFP+ LAN-WAN
STATUS
ONLINE /
OFFLINE
0 1
2 3
5
7
9
11
13
15
17
19
21
23
•
•
•
•
Cables and Connectors on page 114
•
•
Alarms, Errors, and Events on page 116
Software Release
• Junos OS Release 12.1R2 and later (Type 4)
NOTE: In some Juniper Networks documentation, the 10-Gigabit Ethernet
LAN/WAN PIC with SFP+ (PD-5-10XGE-SFPP) is referred to as the 10-port
10-Gigabit Oversubscribed Ethernet PIC or 10-port 10-Gigabit OSE PIC.
In oversubscribed Ethernet mode (default), all 10 ports are enabled and oversubscription is permitted. In line-rate mode, this PIC does not allow oversubscription and supports only 5 ports ( 0 , 2 , 4 , 6 , and 8 ).
• Junos OS Release 12.2 and later (Type 5)
110 Copyright © 2018, Juniper Networks, Inc.
Chapter 9: 10-Gigabit Ethernet PIC Descriptions
NOTE: In oversubscribed Ethernet mode (default), all 24 ports are enabled and oversubscription is permitted. In line-rate mode, this PIC does not allow oversubscription and supports only 12 ports ( 0 through 11 ).
For information about which FPCs support these PICs, see
“T4000 PIC/FPC Compatibility” on page 8 .
Hardware Features
Type 4 PIC
• Ten 10-Gigabit Ethernet SFP+ ports (only ports 0 , 2 , 4 , 6 , and 8 are supported in line-rate mode)
• Total bandwidth: 50 Gbps
• Power requirements: 3.3 A @ –48 V (158.4 W)
• Model number for 10-port Type 4 PIC with Oversubscription: PD-5-10XGE-SFPP
• High-performance throughput:
• WAN-PHY mode at 9.953 Gbps
• LAN-PHY mode at 10.3 Gbps
• Full-duplex mode
• Large maximum transmission units (MTUs) of up to 9192 bytes
Type 5 PIC
• Twenty-four 10-Gigabit Ethernet SFP+ ports (only ports 0 through 11 are supported in line-rate mode)
• Power requirements: 0.94 A @48 V (45 W)
• Model number for 24-Port Type 5 PIC with Oversubscription: PF-24XGE-SFPP
Software Features
Table 64: Software Features Supported on 10-Port Type 4 PIC with Over subscription
Software Feature T4000 First Supported Junos OS Release
Two modes of operation: 5 ports in line-rate mode, 10 ports in oversubscribed mode
12.1R2
Intelligent handling of oversubscribed traffic
Flexible mapping of port-assigned queues and scheduler resources at both ingress and egress
Strict-priority queue available on a per-port basis
12.1R2
12.1R2
12.1R2
Copyright © 2018, Juniper Networks, Inc.
111
T4000 Core Router Interface Module Reference
Table 64: Software Features Supported on 10-Port Type 4 PIC with Over subscription (continued)
Software Feature T4000 First Supported Junos OS Release
QoS available on a per-port basis
Weighted round-robin (WRR)
Layer 2 Protocol support:
•
•
•
•
•
Ethernet CCC, Ethernet TCC, Ethernet VPLS
VLAN CCC
Extended VLAN TCC
VLAN VPLS
Flexible Ethernet services
Layer 3 Protocol support
•
•
•
IPv4
IPv6
MPLS
VLAN support
•
•
•
•
•
4000 VLANs per PIC
Flex-VLAN tagging support
Interrupt driven link-down detection
Pause frame support
Jumbo frame support
MAC learning, aging, and filtering
12.1R2
12.1R2
12.1R2
12.1R2
12.1R2
12.1R2
MAC policing
Virtual Router Redundancy Protocol (VRRP) support
12.1R2
12.1R2
IEEE 802.3ad link aggregation (For routers in a routing matrix, Junos OS
Release 11.2 and later is required)
NOTE: For PICS that support oversubscription, the PIC must be in line-rate mode to support aggregated Ethernet.
12.1R2
DSCP rewrite 12.1R2
Table 65: Software Features Supported on 24-Port Type 5 PIC with Oversubscription
Software Feature T4000 First Supported Junos OS Release
Modes of operation:
•
•
12 ports in line-rate mode
24 ports in oversubscribed mode
12.2R1
112 Copyright © 2018, Juniper Networks, Inc.
Chapter 9: 10-Gigabit Ethernet PIC Descriptions
Table 65: Software Features Supported on 24-Port Type 5 PIC with Oversubscription (continued)
Software Feature T4000 First Supported Junos OS Release
Mixed-rate mode operation
(configurable 1-Gbps or 10-Gbps speed)
13.3R1
Intelligent handling of oversubscribed traffic
LAN-PHY mode or WAN-PHY mode selectable per port
12.2R1
12.2R1
IEEE 802.3ad link aggregation (on single chassis) (For routers in a routing matrix, Junos OS Release 11.2 and later is required)
NOTE: For PICs that support oversubscription, the PIC must be in line-rate mode to support aggregated Ethernet.
12.2R1
Interface hold timer
Graceful Routing Engine switchover (GRES)
12.2R1
12.2R1
SNMP support to access all 10 Gigabit Ethernet port counters 12.2R1
Layer 2 Protocol support:
•
•
•
•
•
Ethernet CCC, Ethernet TCC, Ethernet VPLS
VLAN CCC
Extended VLAN TCC
VLAN VPLS
Flexible Ethernet services
Layer 3 Protocol support
•
•
•
IPv4
IPv6
MPLS
12.2R1
12.2R1
MAC filtering, accounting, policing, and learning for source media access control (MAC) on logical interfaces
12.2R1
Flexible encapsulation
Single, stacked, and flexible VLAN tagging modes
12.2R1
12.2R1
Native VLAN configuration to allow untagged frames to be received on the tagged interfaces
12.2R1
IEEE 802.3ad Link Aggregation (on single chassis)
NOTE: For PICS that support oversubscription, the PIC must be in line-rate mode to support aggregated Ethernet.
12.2R1
Copyright © 2018, Juniper Networks, Inc.
113
T4000 Core Router Interface Module Reference
Table 65: Software Features Supported on 24-Port Type 5 PIC with Oversubscription (continued)
Software Feature T4000 First Supported Junos OS Release
Defining the VLAN rewrite operation to be applied to the incoming and outgoing frames on logical interfaces on this PIC.
12.2R1
NOTE: Only the Tag Protocol Identifier (TPID) 0x8100 is supported.
Interoperability with other 10-Gigabit Ethernet PICs on M Series and T Series routers in LAN-PHY and WAN-PHY modes.
12.2R1
Behavior aggregate (BA) classification (IPv4 DSCP, IPv6 DSCP,
Inet precedence, IEEE 802.1P, IEEE 802.1AD, MPLS EXP) and fixed classification.
12.2R1
Cables and Connectors
You can install any transceiver supported by the PIC.
• Duplex LC/PC connector (Rx and Tx)
• Fiber-optic 10-Gigabit small form-factor pluggable (SFP+) transceivers.
NOTE: For 1-Gigabit speed, SFP optics is required; SFPP does not support
1-Gigabit.
Type 4 PIC:
• 10GBASE-ER (model number: SFPP-10GE-ER)
• 10GBASE-LR (model number: SFPP-10GE-LR)
• 10GBASE-SR (model number: SFPP-10GE-SR)
• 10BASE-ZR (model number: SFPP-10GE-ZR): Junos OS Release 12.3 and later
• 10GBASE-ZR (model number: SFPP-10G-OTN-XT)
• Supported in Junos OS Release 12.3R5, 13.2R3, 13.3, and later
• NESB compliant
• Dual-rate extended temperature transceiver that supports LAN-PHY and WAN-PHY modes, and OTN rates
Type 5 PIC:
• 10GBASE-SR (model number: SFPP-10GE-SR)
• 10GBASE-LR (model number: SFPP-10GE-LR)
• 10GBASE-ER (model number: SFPP-10GE-ER): Junos OS Release 12.1R2 and later
114 Copyright © 2018, Juniper Networks, Inc.
Chapter 9: 10-Gigabit Ethernet PIC Descriptions
• 10BASE-ZR (model number: SFPP-10GE-ZR): Junos OS Release 12.3 and later
• 10GBASE-ZR (model number: SFPP-10G-OTN-XT)
• Supported in Junos OS Release 12.3R5, 13.2R3, 13.3, and later
• NEBS compliant
• Dual-rate extended temperature transceiver that supports LAN-PHY and WAN-PHY modes, and OTN rates
Optical interface specifications—see the Hardware Compatibility Tool at https://apps.juniper.net/hct/
• 1000BASE-SX (model number: SFP-1GE-SX)
• 1000BASE-LX (model number: SFP-1GE-LX)
Optical interface specifications—see the Hardware Compatibility Tool at https://apps.juniper.net/hct/
LEDs
Port LEDs, one pair for each port. The ports on the Type 4 PIC are labeled PORT 0 through
PORT 9 . The ports on the Type 5 PIC are labeled 0 through 23 .
The link status LEDs on the Type 4 PIC are labeled LINK . The Type 5 PIC has no labels for the link status LED.
The link activity LED on the Type 4 PIC is labeled ACT . The Type 5 PIC has no label for the link activity LED.
Table 66: 10-Gigabit Ethernet LAN/WAN PIC with Oversubscription and SFP+ LEDs
Label Color State Description
STATUS — Off PIC is offline and safe to remove from the router.
Port LED
LINK
Green
Yellow
Red
—
Green
On steadily
On steadily
On steadily
Off
On steadily
PIC is operating normally.
PIC is initializing.
PIC has an error or failure.
Port is not enabled.
Port is online with no alarms or failures.
Red
Link activity
LED ACT
—
Green
On steadily
Off
On steadily
The router has detected a failure with alarms.
No packet activity detected on the port.
Port is sending or receiving packets.
Copyright © 2018, Juniper Networks, Inc.
115
T4000 Core Router Interface Module Reference
Alarms, Errors, and Events
Alarms are vendor-specific. Some transceiver vendors might not support every alarm.
• Input laser power
• Input loss of lock
• Input loss of signal
• Input Rx path
• Output A/D data not ready
• Output CDR (clock data recovery)
• Output laser bias current
• Output laser power
• Output laser safety
• Output Tx path
• Module temperature
• Module MOD_NR (module not ready)
• Module P_DOWN (module down)
• Module unplugged or down
• Wire unplugged or down
Related
Documentation
• T4000 PIC Description
•
T4000 PICs Supported on page 3
116 Copyright © 2018, Juniper Networks, Inc.
Chapter 9: 10-Gigabit Ethernet PIC Descriptions
10-Gigabit Ethernet LAN/WAN PIC with XFP (T4000 Router)
•
•
•
•
Cables and Connectors on page 118
•
•
Alarms, Errors, and Events on page 119
Software Release
Junos OS Release 12.1R2 and later (Type 4)
For information on which FPCs support this PIC, see
“T4000 PIC/FPC Compatibility” on page 8 .
Hardware Features
• Four 10-Gigabit Ethernet ports
• Power requirements: 0.9 A @48 V (43 W)
• Model number: PD-4XGE-XFP
• High-performance throughput
• WAN-PHY mode at 9.953 Gbps
Copyright © 2018, Juniper Networks, Inc.
117
T4000 Core Router Interface Module Reference
• LAN-PHY mode at 10.3125 Gbps
• Full-duplex mode
• Large maximum transmission units (MTUs) of up to 9192 bytes
Software Features
Table 67: Software Features Supported
T4000 First Supported Junos OS
Release
12.1R2
Software Feature
Configurable WAN-PHY mode options:
•
•
•
• loopback mpls path-trace trigger
Optical diagnostics, monitoring, and alarms
Flexible Ethernet Services Encapsulation
802.1q virtual LANs (VLANs)
Ethernet OAM 802.1ag continuity check
Ethernet OAM 802.3ah (remote loopback is not supported for this PIC)
VLAN stacking
Channels defined by two stacked VLAN tags
Multiple tag protocol identifiers (TPID) support
IP service for nonstandard TPID and stacked VLAN tags
MAC learning, accounting, and filtering
Virtual Router Redundancy Protocol (VRRP) support
12.1R2
12.1R2
12.1R2
12.1R2
12.1R2
12.1R2
12.1R2
12.1R2
12.1R2
12.1R2
12.1R2
Cables and Connectors
You can install any transceiver supported by the PIC.
• Connector: Duplex LC (Rx and Tx)
• Fiber-optic 10-Gigabit small form-factor pluggable (XFP) transceivers:
• 10GBASE-S (model number: XFP-10G-S)
• 10GBASE-L (model number: XFP-10G-L-OC192-SR1)
118 Copyright © 2018, Juniper Networks, Inc.
Chapter 9: 10-Gigabit Ethernet PIC Descriptions
• 10GBASE-E (model number: XFP-10G-E-OC192-IR2)
• 10GBASE-Z (model number: XFP-10G-Z-OC192-LR2)
• Optical interface specifications—see the Hardware Compatibility Tool at https://apps.juniper.net/hct/
• DWDM Tunable XFP transceivers:
• 10GBASE-ZR (model number: XFP-10G-CBAND-T50-ZR)
• Optical interface specifications—see the Hardware Compatibility Tool at https://apps.juniper.net/hct/
• DWDM supported wavelengths—see
“10-Gigabit Ethernet DWDM Transceiver
(XFP-10G-CBAND-T50-ZR) Wavelengths” on page 22
LEDs
Table 68: 10-Gigabit Ethernet LAN/WAN PIC with XFP LEDs
Label Color State
Off Port LED, labeled
PORT 0 through
PORT 3 , one for each port
—
Green
Yellow
Red
On steadily
On steadily
On steadily
Description
Port is not enabled.
Online with no alarms or failures
Online with alarms for remote failures.
Active with a local alarm; router has detected a failure.
Alarms, Errors, and Events
Alarms are vendor-specific. Some transceiver vendors might not support every alarm.
• Input laser power
• Input loss of lock
• Input loss of signal
• Input Rx path
• Output A/D data not ready
• Output CDR (clock data recovery)
• Output laser bias current
• Output laser power
• Output laser safety
• Output Tx path
• Module temperature
• Module MOD_NR (module not ready)
Copyright © 2018, Juniper Networks, Inc.
119
T4000 Core Router Interface Module Reference
• Module P_DOWN (module down)
• Module unplugged or down
• Wire unplugged or down
Related
Documentation
• T4000 PIC Description
•
T4000 PICs Supported on page 3
120 Copyright © 2018, Juniper Networks, Inc.
CHAPTER 10
40-Gigabit Ethernet PIC Descriptions
•
40-Gigabit Ethernet PIC with CFP (T4000 Router) on page 121
40-Gigabit Ethernet PIC with CFP (T4000 Router)
40 G
TX
RX
STATUS
ONLINE/
OFFLINE
•
•
•
•
Cables and Connectors on page 123
•
•
Alarms, Errors, and Events on page 123
Software Release
Junos OS Release 13.2
Copyright © 2018, Juniper Networks, Inc.
121
T4000 Core Router Interface Module Reference
For information on which FPCs support this PIC, see
“T4000 PIC/FPC Compatibility” on page 8 .
Hardware Features
• One 40-Gigabit Ethernet port
• Power requirement: 1.46 A @ –48 V (70.0 W)
• Model number: PD-1XLE-CFP
• Maximum transmission units (MTUs) up to 9192 bytes
Software Features
Table 69: Software Features Supported
Software Feature
T4000 First Supported Junos
OS Release
Media Access Control (MAC) accounting
NOTE: MAC accounting on this PIC is not supported when aggregated Ethernet is configured.
13.2R1
Source and destination MAC address filtering
Ethernet OAM 802.3ah (remote loopback is not supported for this PIC)
13.2R1
13.2R1
Layer 2 filtering and accounting based on Layer 2 headers
Multiple tag protocol identifiers (TPIDs) used for filtering and counting
13.2R1
13.2R1
Flexible virtual LAN (VLAN) tagging
Channels defined by two stacked VLAN tags
Layer 2 protocols:
•
•
•
•
•
•
•
Flexible Ethernet service
Ethernet circuit cross-connect (CCC)
Ethernet translational cross-connect (TCC)
Ethernet virtual private LAN service (VPLS)
VLAN CCC
Extended VLAN TCC
VLAN VPLS
Layer 3 protocols:
•
•
•
IPV4
IPV6
MPLS
Optical control features (vendor dependent)
13.2R1
13.2R1
13.2R1
13.2R1
13.2R1
122 Copyright © 2018, Juniper Networks, Inc.
Chapter 10: 40-Gigabit Ethernet PIC Descriptions
Table 69: Software Features Supported (continued)
Software Feature
IEEE 802.3ad Link Aggregation
Graceful Routing Engine switchover (GRES)
Cables and Connectors
• Duplex SC/PC connector (RX and TX)
• 40-Gigabit Ethernet CFP transceiver: 40GBASE-LR4 (model number:
CFP-40GBASE-LR4)
• Optical interface specifications—see the Hardware Compatibility Tool at https://apps.juniper.net/hct/
LEDs
Table 70: 40-Gigabit Ethernet PIC with CFP LEDs
Label Color State
STATUS — Off
Green
Yellow
Red
Port LED Rx —
Green
On steadily
On steadily
On steadily
Off
On steadily
Port LED Tx —
Green
Off
On steadily
Description
PIC is not enabled.
Online with no alarms or failures.
PIC is initializing.
PIC has a remote or local fault.
Port might be on, but there is a local or remote fault.
Port is receiving data.
Port might be on, but there is a local fault.
Port is transmitting data.
Alarms, Errors, and Events
• Alarm indication signal (AIS)
• Laser bias current high/low alarms and warnings
• Laser Rx power high/low alarms and warnings
• Module not ready alarm
• Module power down alarm
• Module temperature high/low alarms and warnings
T4000 First Supported Junos
OS Release
13.2R1
13.2R1
Copyright © 2018, Juniper Networks, Inc.
123
T4000 Core Router Interface Module Reference
• Rx CDR loss of lock alarm
• Rx loss of signal alarm
• Rx not ready alarm
• Tx CDR loss of lock alarm
• Tx data not ready alarm
• Tx laser fault alarm
• Tx not ready alarm
Related
Documentation
• T4000 PIC Description
•
T4000 PIC/FPC Compatibility on page 8
•
T4000 PICs Supported on page 3
124 Copyright © 2018, Juniper Networks, Inc.
CHAPTER 11
100-Gigabit Ethernet PIC Descriptions
•
100-Gigabit Ethernet PIC with CFP (T4000 Router) on page 125
100-Gigabit Ethernet PIC with CFP (T4000 Router)
Figure 13: Type 5 100-Gigabit Ethernet PIC
•
•
•
•
Cables and Connectors on page 129
•
•
Alarms, Errors, and Events on page 131
Software Release
• Junos OS Release 12.1R1 and later (Type 5)
• Junos OS Release 12.1R2 and later (Type 4)
Copyright © 2018, Juniper Networks, Inc.
125
T4000 Core Router Interface Module Reference
NOTE: The Type 4 100-Gigabit Ethernet PIC is available only packaged in an assembly with the T1600-FPC4-ES FPC.
For information on which FPCs support these PICs, see
“T4000 PIC/FPC Compatibility” on page 8 .
Hardware Features
Type 5 PIC
• One 100-Gigabit Ethernet port
• Power requirements with LR4 transceiver: 1.19 A @48 V (57 W)
• Model number: PF-1CGE-CFP
Type 4 PIC
• One 100-Gigabit Ethernet port
• Power requirements for PD-1CE-CFP-FPC4 (PIC and FPC): 9.48 A @48 V (455 W)
• Model number: PD-1CE-CFP-FPC4
• PIC 0 and PIC 1 are connected by a bridge board.
• There are two physical interfaces when the 100-Gigabit Ethernet PIC is online. Each physical interface represents one of two internal 50-Gigabit Ethernet Packet Forwarding
Engines (PFEs) in the FPC. PFE0 is physical interface 0, PFE1 is physical interface 1.
The following example shows the CLI representation of the physical interface. The interface type is et , fpc is the FPC slot number, the PIC slot is always 0 , and the PFEs are 0:0 for PFE0 and 0:1 for PFE1.
• etfpc /0/0:0
• etfpc /0/0:1
• You must also configure two logical interfaces under each physical interface. The following CLI example shows the logical interfaces.
• etfpc /0/0:0.0
and etfpc /0/0:0.1
• etfpc /0/0:1.0
and etfpc /0/0:1.1
• Support for MTUs up to 9192 bytes
Software Features
Table 71: Software Features Supported on Type 5 PIC
Software Feature
Interface hold timer
T4000 First Supported
Junos OS Release
12.1R1
126 Copyright © 2018, Juniper Networks, Inc.
Chapter 11: 100-Gigabit Ethernet PIC Descriptions
Table 71: Software Features Supported on Type 5 PIC (continued)
Software Feature
T4000 First Supported
Junos OS Release
Support for 100 Gigabit Ethernet MIBs
Graceful Routing Engine switchover (GRES)
12.1R1
12.1R1
Layer 3 protocols:
•
•
•
IPV4
IPV6
MPLS
12.1R1
MAC filtering, accounting, policing, and learning for source media access control (MAC) on logical interfaces
12.1R1
Layer 2 protocols:
•
•
•
•
•
•
•
Flexible Ethernet service
Ethernet circuit cross-connect (CCC)
Ethernet translational cross-connect (TCC)
Ethernet virtual private LAN service (VPLS)
VLAN CCC
Extended VLAN TCC
VLAN VPLS
Flexible encapsulation
12.1R1
12.1R1
12.1R1
Single, stacked, and flexible VLAN tagging modes
Native VLAN configuration to allow untagged frames to be received on the tagged interfaces 12.1R1
12.1R1
IEEE 802.3ad Link Aggregation (on single chassis)
Defining the VLAN rewrite operation to be applied to the incoming and outgoing frames on logical interfaces on this PIC
12.1R1
NOTE: Only the Tag Protocol Identifier (TPID) 0x8100 is supported.
Behavior aggregate (BA) classification (IPv4 DSCP, IPv6 DSCP, Inet precedence, IEEE 802.1P,
IEEE 802.1AD, MPLS EXP) and fixed classification.
12.1R1
Type 5 (model number PF-1CGE-CFP) interoperability with the 100-Gigabit Ethernet PIC (model number PD-1CE-CFP-FOC4) supported in Junos OS Release 12.1R2 and later
12.1R1
Copyright © 2018, Juniper Networks, Inc.
127
T4000 Core Router Interface Module Reference
Table 72: Software Features Supported on Type 4 PIC
Software Feature
Media Access Control (MAC) accounting
NOTE: MAC accounting on this PIC is not supported when aggregated Ethernet is configured.
Source and destination MAC address filtering
T4000 First Supported
Junos OS Release
12.1R2
12.1R2
Ethernet OAM 802.3ah (remote loopback is not supported for this PIC)
Layer 2 filtering and accounting based on Layer 2 headers
Multiple tag protocol identifiers (TPIDs) used for filtering and counting
Flexible virtual LAN (VLAN) tagging
Channels defined by two stacked VLAN tags 12.1R2
12.1R2
Layer 2 protocols:
•
•
•
•
•
•
•
Flexible Ethernet service
Ethernet circuit cross-connect (CCC)
Ethernet translational cross-connect (TCC)
Ethernet virtual private LAN service (VPLS)
VLAN CCC
Extended VLAN TCC
VLAN VPLS
Layer 3 protocols:
•
•
•
IPV4
IPV6
MPLS
Optical control features (vendor dependent)
12.1R2
Graceful Routing Engine switchover (GRES)
12.1R2
IEEE 802.3ad Link Aggregation
NOTE: Aggregated Ethernet must be configured on this PIC to support interoperability with
100-Gigabit Ethernet PIC (model number PF-1CGE-CFP) or the 100-Gigabit Ethernet MIC (model number MIC3-3D-1X100GE-CFP) .
12.1R2
12.1R2
12.1R2
12.1R2
12.1R2
12.1R2
128 Copyright © 2018, Juniper Networks, Inc.
Chapter 11: 100-Gigabit Ethernet PIC Descriptions
Table 72: Software Features Supported on Type 4 PIC (continued)
Software Feature
T4000 First Supported
Junos OS Release
Interoperability for Type 4 (model number: PD-1CE-CFP-FPC4)
•
•
•
VLAN-steering provides interoperability with 100-Gigabit Ethernet interfaces from other vendors
Interoperability between 100-Gigabit Ethernet PIC (model number PD-1CE-CFP-FPC4) and the
100-Gigabit Ethernet PIC (model number PF-1CGE-CFP) supported in Junos OS Release 12.1R2
and later
Interoperability between 100-Gigabit Ethernet PIC (model number PD-1CE-CFP-FPC4) and the
100-Gigabit Ethernet MIC (model number MIC3-3D-1X100GE-CFP) supported in Junos OS Release
12.1R2
12.1R2
Cables and Connectors
• You can install any 100-Gigabit Ethernet CFP transceiver supported by the PIC.
• 100GBASE-LR4 (model number: CFP-100GBASE-LR4)
• Duplex SC connector (RX and TX)
• Junos OS Release 12.1 and later
• 100GBASE-LR4 (model number: CFP-GEN2-100GBASE-LR4 and part number:
740-047682)
• Duplex LC connector (RX and TX)
• Junos OS Release 12.3R5, 13.2R3, 13.3R1, and later releases
NOTE: The “GEN2” optics have been redesigned with newer versions of internal components for reduced power consumption.
• 100GBASE-ER4 (model number: CFP-100GBASE-ER4)
• Duplex LC connector (RX and TX)
• Junos OS Release 12.3 and later
• 100GBASE-ER4 (model number: CFP-GEN2-CGE-ER4 and part number:
740-049763)
• Duplex LC connector (RX and TX)
• Junos OS Release 12.3R5, 13.2R3, 13.3R1, and later releases
NOTE: The “GEN2” optics have been redesigned with newer versions of internal components for reduced power consumption.
• 100GBASE-SR10 (model number: CFP-100GBASE-SR10)
Copyright © 2018, Juniper Networks, Inc.
129
T4000 Core Router Interface Module Reference
LEDs
Table 73: Type 5 LEDs
Label Color
STATUS
Link STATUS
LED
—
Red
Green
Link ACTIVITY
LED
—
Green
—
Green
Yellow
Red
Table 74: Type 4 PIC LEDs
Label Color
Two tricolor
STATUS LEDs
( P1C 0 and P1C 1 )
—
Green
Yellow
Red
Rx LED ( P1C 1 )
Tx LED ( P1C 1 )
—
Green
—
Green
• 24-fiber MPO
• Junos OS Release 12.3 and later
• Optical interface specifications—see the Hardware Compatibility Tool at https://apps.juniper.net/hct/
State
Off
On steadily
On steadily
On steadily
Off
On steadily
Off
On steadily
State
Off
On steadily
On steadily
On steadily
Off
On steadily
On steadily
Off
Flashing
Description
PIC is powered down and offline.
PIC is online with all voltages in range.
PIC is initializing.
PIC has an error or failure.
Port is off.
Port detecting failure with alarms.
Port is online and link is up.
No link activity.
Indicates link activity for the port.
Description
PIC is powered down and offline.
PIC is online with no alarms or failures.
PIC is initializing.
PIC has a remote or local fault.
Port might be on, but there is a local or remote fault.
Port is receiving data.
Port might be on, but there is a local fault.
Port is transmitting data.
130 Copyright © 2018, Juniper Networks, Inc.
Chapter 11: 100-Gigabit Ethernet PIC Descriptions
Alarms, Errors, and Events
Alarms are vendor-specific. Some transceiver vendors might not support every alarm.
• Input laser power
• Input loss of lock
• Input loss of signal
• Input Rx path
• Output A/D data not ready
• Output CDR (clock data recovery)
• Output laser bias current
• Output laser power
• Output laser safety
• Output Tx path
• Module temperature
• Module MOD_NR (module not ready)
• Module P_DOWN (module down)
• Module unplugged or down
• Wire unplugged or down
Related
Documentation
• T4000 PIC Description
•
T4000 PICs Supported on page 3
Copyright © 2018, Juniper Networks, Inc.
131
T4000 Core Router Interface Module Reference
132 Copyright © 2018, Juniper Networks, Inc.
CHAPTER 12
Services PIC Descriptions
•
MultiServices PICs (T4000 Router) on page 133
•
Tunnel Services PICs (T4000 Router) on page 137
MultiServices PICs (T4000 Router)
Figure 14: MultiServices 400 PIC
Copyright © 2018, Juniper Networks, Inc.
133
T4000 Core Router Interface Module Reference
Figure 15: MultiServices 500 PIC
•
•
•
•
Software Release
• MultiServices 400: Junos OS Release 12.2R1 and later (Type 2)
• MultiServices 500: Junos OS Release 12.1R2 and later (Type 3)
For information on which FPCs support this PIC, see
“T4000 PIC/FPC Compatibility” on page 8 .
Hardware Features
• Individual licenses must be purchased for services.
• Power requirement:
• Multiservices 400: 0.69 A @ 48 V (33 W)
• Multiservices 500: 0.83 A @ 48 V (40 W)
• Model number for Multiservices 400 PIC: PB-MS-400-2
• Model number for Multiservices 500 PIC: PB-MS-500-3
• Multiservices 400: up to 3.2 million flows
• Multiservices 500: up to 3.2 million flows
134 Copyright © 2018, Juniper Networks, Inc.
Chapter 12: Services PIC Descriptions
Software Features
• Support for up to 2000 service sets
• Support for MTUs up to 9192 bytes for Gigabit Ethernet and SONET interfaces
Depending on your Junos OS Release and individual licenses, software features for this
PIC can include the features listed in
Table 75 on page 135 . For more information about
the software features available for services PICs, see the Junos OS Services Interfaces
Library for Routing Devices .
Table 75: MultiServices PICs Software Features Supported on the T4000 Router
GRE Key – –
GRE dont-fragment –
Stateful firewall with packet inspection: detects SYN attacks, ICMP and UDP floods, and ping-of-death attacks
–
–
–
Network Address Translation (NAT) for IP addresses
Port Address Translation (PAT) for port numbers
IP Security (IPSec) encryption
Flow aggregation
Active flow monitoring exports cflowd version 5 and version 8 records
–
Active flow monitoring exports flow monitoring version 9 records, based on RFC 3954
–
–
–
–
–
Passive flow monitoring
Passive flow collection
Flow-tap
Dynamic flow capture
Real-time performance monitoring
Link Services
Traffic sampling
–
–
12.2
12.2
–
12.2
–
–
–
–
–
–
–
12.1R2
–
–
–
12.1R2
12.1R2
12.1R2
Copyright © 2018, Juniper Networks, Inc.
135
T4000 Core Router Interface Module Reference
Table 75: MultiServices PICs Software Features Supported on the T4000 Router (continued)
– – Tunnel services:
•
•
•
IP-IP unicast tunneling
GRE unicast tunneling—Supports GRE fragmentation
Protocol Independent Multicast (PIM) sparse mode unicast tunneling
Virtual tunnel interface for Layer 3 VPNs – –
–
–
–
–
Layer 2 Tunneling Protocol (L2TP)
Voice services:
• Compressed Real-Time Transport Protocol (CRTP)
Encapsulations:
•
•
Multilink Frame Relay (MLFR)
Multilink Point-to-Point Protocol (MLPP)
– –
LEDs
Table 76: MultiServices PIC LEDs
Label Color
— PIC STATUS
LED, one tricolor
Green
Yellow
Red
State
Off
On steadily
On steadily
On steadily
Application
APP STATUS
LED, one bicolor
—
Green
Yellow
Off
On steadily
On steadily
Description
PIC is offline and it is safe to remove it from the chassis.
PIC is operating normally.
PIC is initializing.
PIC has an error or failure and no further harm can be done by removing it from the chassis.
Service is not running.
Service is running under acceptable load.
Service is overloaded.
Related
Documentation
• T4000 PIC Description
•
T4000 PICs Supported on page 3
136 Copyright © 2018, Juniper Networks, Inc.
Chapter 12: Services PIC Descriptions
Tunnel Services PICs (T4000 Router)
•
•
•
•
Software Release
• Junos OS Release 12.1R2 and later (Type 1)
• Junos OS Release 12.2R2 and later (Type 2)
• Junos OS Release 12.1R2 and later (Type 3)
For information on which FPCs support this PIC, see
“T4000 PIC/FPC Compatibility” on page 8 .
Hardware Features
• Power requirement: 0.07 A @ 48 V (3.4 W)
• Model number for Type 1 Tunnel Services PIC: PB-TUNNEL1
• Model number for Type 2 Tunnel Services PIC: PB-TUNNEL
• Model number for Type 3 Tunnel Services PIC: PC-TUNNEL
• Loopback function that encapsulates and de-encapsulates packets
• OC12/STM4 tunneling bandwidth on Type 1 FPC
• OC48/STM16 tunneling bandwidth on Type 2 FPC
• OC192/STM64 tunneling bandwidth on Type 3 FPC
Software Features
For a list of the software features available for services PICs, see the Junos Services
Interfaces Configuration Release .
Copyright © 2018, Juniper Networks, Inc.
137
T4000 Core Router Interface Module Reference
• IP-IP unicast tunneling
• GRE unicast tunneling
• PIM sparse mode unicast tunneling
LEDs
Table 77: Tunnel Services PIC LEDs
Label Color State
One STATUS
LED, tricolor
—
Green
Off
On steadily
Yellow
Red
On steadily
On steadily
Description
Not enabled.
Online with no alarms or failures.
Online with alarms for remote failures.
Active with a local alarm; router has detected a failure.
Related
Documentation
• T4000 PIC Description
•
T4000 PICs Supported on page 3
138 Copyright © 2018, Juniper Networks, Inc.
CHAPTER 13
SONET/SDH PIC Descriptions
•
SONET/SDH OC3/STM1 (Multi-Rate) PICs with SFP (T4000 Router) on page 139
•
SONET/SDH OC12/STM4 (Multi-Rate) PICs with SFP (T4000 Router) on page 144
•
SONET/SDH OC48c/STM16 PIC with SFP (T4000 Router) on page 148
•
SONET/SDH OC48/STM16 Enhanced IQ (IQE) PIC with SFP (T4000 Router) on page 152
•
SONET/SDH OC48/STM16 (Multi-Rate) PIC with SFP (T4000 Router) on page 156
•
SONET/SDH OC192/STM64 PICs with XFP (T4000 Router) on page 160
•
SONET/SDH OC768c/STM256 PIC (T4000 Router) on page 165
SONET/SDH OC3/STM1 (Multi-Rate) PICs with SFP (T4000 Router)
Figure 16: SONET/SDH OC3/STM1 (Multi-Rate) PIC
(Type 1)
Figure 17: SONET/SDH OC3/STM1 (Multi-Rate) PIC
(Type 2)
•
•
•
•
Cables and Connectors on page 141
Copyright © 2018, Juniper Networks, Inc.
139
T4000 Core Router Interface Module Reference
•
•
Alarms, Errors, and Events on page 142
Software Release
• 4-port: Junos OS Release 12.1R2 and later (Type 1)
• 4-port: Junos OS Release 12.2R2 and later (Type 2)
For information on which FPCs support this PIC, see
“T4000 PIC/FPC Compatibility” on page 8 .
Hardware Features
• Rate-selectable using one of the following rates:
• 1-port OC12/STM4
• 1-port OC12c/STM4c
• 4-port OC3c/STM1c
• Power requirement: 0.40 A @ 48 V (19 W)
• Model number for SONET/SDH OC3/STM1 (Multi-Rate) PIC (Type_1):
PB-40C3-1OC12-SON-SFP
• Model number for SONET/SDH OC3/STM1 (Multi-Rate) PIC (Type_2):
PB-4OC3-1OC12-SON2-SFP
• Multiplexing and demultiplexing
• Rate policing on input
• Rate shaping on output
• Packet buffering, Layer 2 parsing
Software Features
Table 78: Software Features Supported
Software Feature
Optical diagnostics and related alarms
Per-port SONET/SDH framing
IEEE 802.3ad Link Aggregation
Alarm and event counting and detection
Dual-router automatic protection switching (APS)
Multiprotocol Label Switching (MPLS) fast reroute
12.1R2
12.1R2
12.1R2
12.1R2
T4000 First Supported
Junos OS Release (Type 1
PIC)
T4000 First Supported
Junos OS Release (Type 2
PIC)
12.2R2
12.2R2
12.2R2
12.2R2
12.1R2
12.1R2
12.2R2
12.2R2
140 Copyright © 2018, Juniper Networks, Inc.
Chapter 13: SONET/SDH PIC Descriptions
Table 78: Software Features Supported (continued)
Software Feature
Encapsulations:
•
•
•
•
•
Circuit cross-connect (CCC)
Translational cross-connect (TCC)
Frame Relay
High-Level Data Link Control (HDLC)
Point-to-Point Protocol (PPP)
T4000 First Supported
Junos OS Release (Type 1
PIC)
T4000 First Supported
Junos OS Release (Type 2
PIC)
12.1R2
12.2R2
Cables and Connectors
You can install any transceiver supported by the PIC. For information about installing and removing transceivers.
• Duplex LC connector (Rx and Tx)
• SONET/SDH OC3/STM1 small form-factor pluggable (SFP) transceivers:
• Multimode (model number: SFP-OC3-SR)
• Intermediate reach (IR-1) (model number: SFP-OC3-IR)
• Long reach (LR-1) (model number: SFP-OC3-LR)
Optical interface specifications—see
“SONET/SDH OC3/STM1 Optical Interface
• SONET/SDH OC12/STM4 small form-factor pluggable (SFP) transceivers:
• Short reach (model number: SFP-OC12-SR)
• Intermediate reach (IR-1) (model number: SFP-OC312-IR)
• Long reach (LR-1) (model number: SFP-OC12-LR)
Optical interface specifications—see
“SONET/SDH OC12/STM4 Optical Interface
NOTE: To extend the life of the laser, when a PIC is not being actively used with any valid links, take the PIC offline until you are ready to establish a link to another device. For information about taking a PIC offline, see the request chassis pic offline command in request chassis pic.
Copyright © 2018, Juniper Networks, Inc.
141
T4000 Core Router Interface Module Reference
LEDs
Table 79: SONET/SDH OC3/STM1 (Multi-Rate) PIC with SFP LEDs
Label Color State Description
One tricolor per port
—
Green
Yellow
Red
Off
On steadily
On steadily
On steadily
Not enabled.
Online with no alarms or failures.
Online with alarms for remote failures.
Active with a local alarm; router has detected a failure.
Alarms, Errors, and Events
• SONET alarms:
• Alarm indication signal—line (AIS-L)
• Alarm indication signal—path (AIS-P)
• Bit error rate—signal degrade (BERR-SD)
• Bit error rate—signal fail (BERR-SF)
• Bit interleaved parity (BIP) error B1, B2, B3
• Far-end bit error: remote error indication—line (REI-L), far-end line coding violations
(CV-LFE)
• Far-end bit error: remote error indication—path (REI-P), far-end path coding violations
(CV-PFE)
• Loss of frame (LOF)
• Loss of pointer (LOP-P)
• Loss of signal (LOS)
• Payload label mismatch (PLM-P)
• Payload unequipped (unequipped STS at path level) (UNEQ-P)
• Remote defect indication—line (RDI-L)
• Remote defect indication—path (RDI-P)
• SDH alarms:
• Administrative unit alarm indication signal (AU-AIS)
• Bit error rate signal degrade (BERR-SD)
• Bit error rate signal fail (BERR-SF)
• Bit interleaved parity (BIP) error B1, B2, B3
• Higher order path—payload label mismatch (HP-PLM)
142 Copyright © 2018, Juniper Networks, Inc.
Chapter 13: SONET/SDH PIC Descriptions
• Higher order path—loss of pointer (HP-LOP)
• Higher order path—remote defect indication (HP-RDI)
• Higher order path—unequipped (HP-UNEQ)
• Loss of frame (LOF)
• Loss of signal (LOS)
• Multiplex section—alarm indication signal (MS-AIS)
• Multiplex section—remote defect indication (MS-RDI)
• Multiplex section—remote error indication (MS-REI)
• Error detection:
• Errored seconds (ES-S, ES-L, ES-P)
• Far-end errored seconds (ES-LFE, ES-PFE)
• Far-end severely errored seconds (SES-LFE, SES-PFE)
• Far-end unavailable seconds (UAS-LFE, UAS-PFE)
• Severely errored framing (SEF)
• Severely errored framing seconds (SEFS-S)
• Severely errored seconds (SES-S, SES-L, SES-P)
• Unavailable seconds (UAS-L, UAS-P)
Related
Documentation
• T4000 PIC Description
•
T4000 PICs Supported on page 3
Copyright © 2018, Juniper Networks, Inc.
143
T4000 Core Router Interface Module Reference
SONET/SDH OC12/STM4 (Multi-Rate) PICs with SFP (T4000 Router)
Figure 18: 1-Port SONET/SDH OC12/STM4 (Multi-Rate)
PIC
Figure 19: 4-Port SONET/SDH OC12/STM4 (Multi-Rate)
PIC
•
•
•
•
Cables and Connectors on page 146
•
•
Alarms, Errors, and Events on page 147
Software Release
• Junos OS Release 12.1R2 ander later
• Junos OS Release 12.2R2 and later (Type 2)
For information on which FPCs support this PIC, see
“T4000 PIC/FPC Compatibility” on page 8 .
Hardware Features
• 1-port: Rate-selectable using one of the following rates:
• 1-port OC3/STM1
• 1-port OC12/STM4
• 1-port OC12c/STM4c
• 4-port: Rate-selectable using one of the following rates:
144 Copyright © 2018, Juniper Networks, Inc.
Chapter 13: SONET/SDH PIC Descriptions
• 1-port OC12/STM4
• 1-port OC48/STM16
• 1-port OC48c/STM16c
• 4-port OC3c/STM1c
• 4-port OC12c/STM4c
• Power requirement:
• 1-port: 0.20 A @ 48 V (9.5 W)
• 4-port: 0.40 A @ 48 V (19 W)
• Model number for 1-Port SONET/SDH OC12/STM4 (Multi-Rate) PIC:
PB-1OC12-SON-SFP
• Model number for 4-Port SONET/SDH OC12/STM4 (Multi-Rate) PIC:
PB-4OC3-4OC12-SON-SFP
• Multiplexing and demultiplexing
• Rate policing on input
• Rate shaping on output
• Packet buffering, Layer 2 parsing
Software Features
Table 80: Software Features Supported
Software Feature
Optical diagnostics and related alarms
Per-port SONET/SDH framing
Link aggregation
Alarm and event counting and detection
Dual-router automatic protection switching (APS)
Multiprotocol Label Switching (MPLS) fast reroute
Encapsulations:
•
•
•
•
•
Circuit cross-connect (CCC)
Translational cross-connect (TCC)
Frame Relay
High-Level Data Link Control (HDLC)
Point-to-Point Protocol (PPP)
12.1R2
12.1R2
12.1R2
12.1R2
T4000 First Supported
Junos OS Release for 1-port
PIC
T4000 First Supported
Junos OS Release for 4-port
PIC
12.2R2
12.2R2
12.2R2
12.2R2
12.1R2
12.1R2
12.1R2
12.2R2
12.2R2
12.2R2
Copyright © 2018, Juniper Networks, Inc.
145
T4000 Core Router Interface Module Reference
Cables and Connectors
You can install any transceiver supported by the PIC. For information about installing and removing transceivers.
• Duplex LC/PC connector (Rx and Tx)
• SONET/SDH OC3/STM1 small form-factor pluggable (SFP) transceivers:
• Multimode (model number: SFP-OC3-SR)
• Intermediate reach (IR-1) (model number: SFP-OC3-IR)
• Long reach (LR-1) (model number: SFP-OC3-LR)
Optical interface specifications—see
“SONET/SDH OC3/STM1 Optical Interface
• SONET/SDH OC12/STM4 small form-factor pluggable (SFP) transceivers:
• Short reach (model number: SFP-OC12-SR)
• Intermediate reach (IR-1) (model number: SFP-OC312-IR)
• Long reach (LR-1) (model number: SFP-OC12-LR)
Optical interface specifications—see
“SONET/SDH OC12/STM4 Optical Interface
NOTE: To extend the life of the laser, when a PIC is not being actively used with any valid links, take the PIC offline until you are ready to establish a link to another device. For information about taking a PIC offline, see the request chassis pic offline command in request chassis pic.
LEDs
Table 81: SONET/SDH OC12/STM4 (Multi-Rate) PICs with SFP LEDs
Label Color State Description
One tricolor per port
—
Green
Yellow
Red
Off
On steadily
On steadily
On steadily
Not enabled.
Online with no alarms or failures.
Online with alarms for remote failures.
Active with a local alarm; router has detected a failure.
146 Copyright © 2018, Juniper Networks, Inc.
Chapter 13: SONET/SDH PIC Descriptions
Alarms, Errors, and Events
• SONET alarms:
• Alarm indication signal—line (AIS-L)
• Alarm indication signal—path (AIS-P)
• Bit error rate—signal degrade (BERR-SD)
• Bit error rate—signal fail (BERR-SF)
• Bit interleaved parity (BIP) error B1, B2, B3
• Far-end bit error: remote error indication—line (REI-L), far-end line coding violations
(CV-LFE)
• Far-end bit error: remote error indication—path (REI-P), far-end path coding violations
(CV-PFE)
• Loss of frame (LOF)
• Loss of pointer (LOP-P)
• Loss of signal (LOS)
• Payload label mismatch (PLM-P)
• Payload unequipped (unequipped STS at path level) (UNEQ-P)
• Remote defect indication—line (RDI-L)
• Remote defect indication—path (RDI-P)
• SDH alarms:
• Administrative unit alarm indication signal (AU-AIS)
• Bit error rate signal degrade (BERR-SD)
• Bit error rate signal fail (BERR-SF)
• Bit interleaved parity (BIP) error B1, B2, B3
• Higher order path—payload label mismatch (HP-PLM)
• Higher order path—loss of pointer (HP-LOP)
• Higher order path—remote defect indication (HP-RDI)
• Higher order path—unequipped (HP-UNEQ)
• Loss of frame (LOF)
• Loss of signal (LOS)
• Multiplex section—alarm indication signal (MS-AIS)
• Multiplex section—remote defect indication (MS-RDI)
• Multiplex section—remote error indication (MS-REI)
Copyright © 2018, Juniper Networks, Inc.
147
T4000 Core Router Interface Module Reference
• Error detection:
• Errored seconds (ES-S, ES-L, ES-P)
• Far-end errored seconds (ES-LFE, ES-PFE)
• Far-end severely errored seconds (SES-LFE, SES-PFE)
• Far-end unavailable seconds (UAS-LFE, UAS-PFE)
• Severely errored framing (SEF)
• Severely errored framing seconds (SEFS-S)
• Severely errored seconds (SES-S, SES-L, SES-P)
• Unavailable seconds (UAS-L, UAS-P)
Related
Documentation
• T4000 PIC Description
•
T4000 PICs Supported on page 3
SONET/SDH OC48c/STM16 PIC with SFP (T4000 Router)
•
•
•
•
Cables and Connectors on page 149
•
•
Alarms, Errors, and Events on page 150
Software Release
Junos OS Release 12.1R2 and later
148 Copyright © 2018, Juniper Networks, Inc.
Chapter 13: SONET/SDH PIC Descriptions
For information on which FPCs support this PIC, see
“T4000 PIC/FPC Compatibility” on page 8 .
Hardware Features
• Four OC48 ports
• Power requirement: 0.46 A @ 48 V (22.1 W)
• Model number: PC-4OC48-SON-SFP
• Multiplexing and demultiplexing on the 1-port PIC
• Rate policing on input
• Rate shaping on output
• Packet buffering, Layer 2 parsing
Software Features
Table 82: Software Features Supported
Software Feature
Optical diagnostics and related alarms
Configuration of SONET or SDH framing on a per-port basis
SONET/SDH framing
IEEE 802.3ad Link Aggregation
Alarm and event counting and detection
Dual-router automatic protection switching (APS)
Multiprotocol Label Switching (MPLS) fast reroute
Layer 2 protocols:
•
•
•
•
•
Circuit cross-connect (CCC)
Translational cross-connect (TCC)
Frame Relay
High-Level Data Link Control (HDLC)
Point-to-Point Protocol (PPP)
T4000 First Supported Junos OS
Release
12.1R2
12.1R2
12.1R2
12.1R2
12.1R2
12.1R2
12.1R2
12.1R2
Cables and Connectors
You can install any transceiver supported by the PIC. For information about installing and removing.
• Duplex LC connector (Rx and Tx)
Copyright © 2018, Juniper Networks, Inc.
149
T4000 Core Router Interface Module Reference
• SONET/SDH OC48/STM16 fiber-optic SFP transceivers:
• Short reach (SR-1) (model number: SFP-1OC48-SR)
• Intermediate reach (IR-1) (model number: SFP-1OC48-IR)
• Long reach (LR-1) (model number: SFP-1OC48-LR)
Optical interface specifications—see
“SONET/SDH OC48/STM16 Optical Interface
NOTE: To extend the life of the laser, when a PIC is not being actively used with any valid links, take the PIC offline until you are ready to establish a link to another device. For information about taking a PIC offline, see the request chassis pic offline command in request chassis pic.
LEDs
Table 83: SONET/SDH OC48c/STM16 PIC with SFP LEDs
Label Color State
STATUS LED, one tricolor per port
—
Green
Yellow
Red
Off
On steadily
On steadily
On steadily
Description
Not enabled
Online with no alarms or failures
Online with alarms for remote failures
Active with a local alarm; router has detected a failure
Alarms, Errors, and Events
• SONET alarms:
• Alarm indication signal—line (AIS-L)
• Alarm indication signal—path (AIS-P)
• Bit error rate—signal degrade (BERR-SD)
• Bit error rate—signal fail (BERR-SF)
• Bit interleaved parity (BIP) error B1, B2, B3
• Far-end bit error: remote error indication—line (REI-L), far-end line coding violations
(CV-LFE)
• Far-end bit error: remote error indication—path (REI-P), far-end path coding violations
(CV-PFE)
• Loss of frame (LOF)
• Loss of pointer (LOP-P)
• Loss of signal (LOS)
150 Copyright © 2018, Juniper Networks, Inc.
Chapter 13: SONET/SDH PIC Descriptions
• Payload label mismatch (PLM-P)
• Payload unequipped (unequipped STS at path level) (UNEQ-P)
• Remote defect indication—line (RDI-L)
• Remote defect indication—path (RDI-P)
• SDH alarms:
• Administrative unit alarm indication signal (AU-AIS)
• Bit error rate signal degrade (BERR-SD)
• Bit error rate signal fail (BERR-SF)
• Bit interleaved parity (BIP) error B1, B2, B3
• Higher order path—payload label mismatch (HP-PLM)
• Higher order path—loss of pointer (HP-LOP)
• Higher order path—remote defect indication (HP-RDI)
• Higher order path—unequipped (HP-UNEQ)
• Loss of frame (LOF)
• Loss of signal (LOS)
• Multiplex section—alarm indication signal (MS-AIS)
• Multiplex section—remote defect indication (MS-RDI)
• Multiplex section—remote error indication (MS-REI)
• Error detection:
• Errored seconds (ES-S, ES-L, ES-P)
• Far-end errored seconds (ES-LFE, ES-PFE)
• Far-end severely errored seconds (SES-LFE, SES-PFE)
• Far-end unavailable seconds (UAS-LFE, UAS-PFE)
• Severely errored framing (SEF)
• Severely errored framing seconds (SEFS-S)
• Severely errored seconds (SES-S, SES-L, SES-P)
• Unavailable seconds (UAS-L, UAS-P)
Related
Documentation
• T4000 PIC Description
•
T4000 PICs Supported on page 3
Copyright © 2018, Juniper Networks, Inc.
151
T4000 Core Router Interface Module Reference
SONET/SDH OC48/STM16 Enhanced IQ (IQE) PIC with SFP (T4000 Router)
•
•
•
•
Cables and Connectors on page 153
•
•
Alarms, Errors, and Events on page 154
Software Release
Junos OS Release 13.2 and later (Type 3)
For information on which FPCs support this PIC, see
“T4000 PIC/FPC Compatibility” on page 8 .
Hardware Features
• Four OC48/STM16 ports
• Clear channel functionality
• SONET and SDH is configured on a per-port granularity
• Power requirement: 1.06 A @ 48 V (51 W)
• Weight: 1.6 lb (0.725 kg)
• Model number: PC-4OC48-STM16-IQE-SFP
• Ports are numbered:
152 Copyright © 2018, Juniper Networks, Inc.
Chapter 13: SONET/SDH PIC Descriptions
• Top row: 0 and 1 from left to right
• Bottom row: 2 and 3 from left to right
• Maximum transmission units (MTUs) of up to 9192 bytes
Software Features
Table 84: Software Features Supported
Software Feature
T4000 First Supported
Junos OS Release
Quality of service (QoS) per channel: weighted round-robin (WRR), random early detection (RED), weighted random early detection (WRED)
13.2R1
Fine-grained egress queuing per logical interface. See the Class of Service Feature Guide for Routing
Devices and EX9200 Switches for more information about class-of-service features
13.2R1
Packet buffering
Local line and remote payload loopback testing
13.2R1
13.2R1
Optical diagnostics and monitoring 13.2R1
Clocking options: internal or external/loop mode. Each OC48 transmitter port is configured either in internal or external mode. The default clocking option is internal mode.
13.2R1
Encapsulations:
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Extended Frame Relay for circuit cross-connect (CCC) and translational cross-connect (TCC)
Flexible Frame Relay
Frame Relay
Frame Relay for CCC
Frame Relay for TCC
Frame Relay port CCC
High-Level Data Link Control (HDLC)
HDLC framing for CCC
HDLC framing for TCC
MPLS CCC
MPLS TCC
Point-to-Point Protocol (PPP)
PPP for CCC
PPP for TCC
13.2R1
Cables and Connectors
You can install any transceiver supported by the PIC.
• Duplex LC connector (Rx and Tx)
• SONET/SDH OC48/STM16 small form-factor pluggable (SFP) transceivers:
Copyright © 2018, Juniper Networks, Inc.
153
T4000 Core Router Interface Module Reference
• Short reach (SR-1) (model number: SFP-1OC48-SR)
• Intermediate reach (IR-1) (model number: SFP-1OC48-IR)
• Long reach (LR-1) (model number: SFP-1OC48-LR)
Optical interface specifications—see
“SONET/SDH OC48/STM16 Optical Interface
NOTE: To extend the life of the laser, when a PIC is not being actively used with any valid links, take the PIC offline until you are ready to establish a link to another device. For information about taking a PIC offline, see the request chassis pic offline command in request chassis pic.
LEDs
Table 85: SONET/SDH OC48/STM16 Enhanced IQ (IQE) PIC with SFP LEDs
Label Color State Description
Ok LED, one tricolor
—
Green
Yellow
Red
Off
On steadily
On steadily
On steadily
PIC is offline and safe to remove from the router.
PIC is operating normally.
PIC is initializing.
PIC has an error or failure.
APP LED, one green per port
—
Green
Port LEDs, one tricolor per port
—
Green
Yellow
Red
Off
On steadily
Off
On steadily
On steadily
On steadily
Service is not running.
Green—Service is running under acceptable load.
Not enabled.
Online with no alarms or failures.
Online with alarms for remote failures.
Active with a local alarm; router has detected a failure.
Alarms, Errors, and Events
SONET alarms:
• Loss of light (LOL)
• Phase lock loop (PLL)
• Loss of frame (LOF)
• Loss of signal (LOS)
154 Copyright © 2018, Juniper Networks, Inc.
Chapter 13: SONET/SDH PIC Descriptions
• Severely errored frame (SEF)
• Alarm indicator signal—line (AIS-L)
• Alarm indicator signal—path (AIS-P)
• Loss of pointer (LOP)
• Bit error rate—signal degrade (BERR-SD)
• Bit error rate—signal fail (BERR-SF)
• Remote defect indicator—line (RDI-L)
• Remote defect indicator—path (RDI-P)
• Remote error indicator (REI)
• Unequipped (UNEQ)
• Payload label mismatch—path (PLM-P)
SDH alarms:
• Loss of light (LOL)
• Phase lock loop (PLL)
• Loss of frame (LOF)
• Loss of signal (LOS)
• Severely errored frame (SEF)
• Multiplex-section alarm indicator signal (MS-AIS)
• H Path alarm indicator signal (HP-AIS)
• Loss of pointer (LOP)
• Bit error rate—signal degrade (BERR-SD)
• Bit error rate—signal fail (BERR-SF)
• Multiplex section—far end receive failure (MS-FERF)
• High order path—far end receive failure (HP-FERF)
• Remote error indicator (REI)
• Unequipped (UNEQ)
• High order path—payload label mismatch - Path (HP-PLM)
Optical diagnostics related alarms:
NOTE: Transceivers from some vendors do not support these fields.
• Temperature high/low alarms and warnings
• Supply voltage high/low alarms and warnings
Copyright © 2018, Juniper Networks, Inc.
155
T4000 Core Router Interface Module Reference
• Tx bias current high/low alarms and warnings
• Tx output power high/low alarms and warnings
• Rx received power high/low alarms and warnings
Related
Documentation
• T4000 PIC Description
•
T4000 PICs Supported on page 3
SONET/SDH OC48/STM16 (Multi-Rate) PIC with SFP (T4000 Router)
•
•
•
•
Cables and Connectors on page 157
•
•
Alarms, Errors, and Events on page 158
Software Release
Junos OS Release 12.2R2 and later (Type 2)
For information on which FPCs support this PIC, see
“T4000 PIC/FPC Compatibility” on page 8 .
Hardware Features
• Rate-selectable using one of the following rates:
• 1-port OC3c/STM1c
• 1-port OC12/STM4
156 Copyright © 2018, Juniper Networks, Inc.
Chapter 13: SONET/SDH PIC Descriptions
• 1-port OC12c/STM4c
• 1-port OC48/STM16
• 1-port OC48c/STM16c
• Power requirement: 0.20 A @ 48 V (9.5 W)
• Model number: PB-1OC48-SON-B-SFP
• Multiplexing and demultiplexing
• Rate policing on input
• Rate shaping on output
• Packet buffering, Layer 2 parsing
Software Features
Table 86: Software Features Supported
Software Feature
Optical diagnostics and related alarms
Per-port SONET/SDH framing
IEEE 802.3ad Link Aggregation
Alarm and event counting and detection
Dual-router automatic protection switching (APS)
Multiprotocol Label Switching (MPLS) fast reroute
Layer 2 protocols:
•
•
•
•
•
Circuit cross-connect (CCC)
Translational cross-connect (TCC)
Frame Relay
High-Level Data Link Control (HDLC)
Point-to-Point Protocol (PPP)
T4000 First Supported Junos OS
Release
12.2R2
12.2R2
12.2R2
12.2R2
12.2R2
12.2R2
12.2R2
Cables and Connectors
You can install any transceiver supported by the PIC. For information about installing and removing transceivers.
• Duplex LC connector (Rx and Tx)
• SONET/SDH OC3/STM1 small form-factor pluggable (SFP) transceivers:
• Multimode (model number: SFP-OC3-SR)
Copyright © 2018, Juniper Networks, Inc.
157
T4000 Core Router Interface Module Reference
• Intermediate reach (IR-1) (model number: SFP-OC3-IR)
• Long reach (LR-1) (model number: SFP-OC3-LR)
Optical interface specifications—see
“SONET/SDH OC3/STM1 Optical Interface
• SONET/SDH OC12/STM4 small form-factor pluggable (SFP) transceivers:
• Short reach (model number: SFP-OC12-SR)
• Intermediate reach (IR-1) (model number: SFP-OC312-IR)
• Long reach (LR-1) (model number: SFP-OC12-LR)
Optical interface specifications—see
“SONET/SDH OC12/STM4 Optical Interface
• SONET/SDH OC48/STM16 fiber-optic SFP transceivers:
• Short reach (SR-1) (model number: SFP-1OC48-SR)
• Intermediate reach (IR-1) (model number: SFP-1OC48-IR)
• Long reach (LR-1) (model number: SFP-1OC48-LR)
Optical interface specifications—see
“SONET/SDH OC48/STM16 Optical Interface
NOTE: To extend the life of the laser, when a PIC is not being actively used with any valid links, take the PIC offline until you are ready to establish a link to another device. For information about taking a PIC offline, see the request chassis pic offline command in request chassis pic.
LEDs
Table 87: SONET/SDH OC48/STM16 (Multi-Rate) PIC with SFP LEDs
Label Color State Description
One tricolor per port
—
Green
Yellow
Off
On steadily
On steadily
Not enabled
Online with no alarms or failures
Online with alarms for remote failures
Red On steadily Active with a local alarm; router has detected a failure
Alarms, Errors, and Events
• SONET alarms:
• Alarm indication signal—line (AIS-L)
• Alarm indication signal—path (AIS-P)
158 Copyright © 2018, Juniper Networks, Inc.
Chapter 13: SONET/SDH PIC Descriptions
• Bit error rate—signal degrade (BERR-SD)
• Bit error rate—signal fail (BERR-SF)
• Bit interleaved parity (BIP) error B1, B2, B3
• Far-end bit error: remote error indication—line (REI-L), far-end line coding violations
(CV-LFE)
• Far-end bit error: remote error indication—path (REI-P), far-end path coding violations
(CV-PFE)
• Loss of frame (LOF)
• Loss of pointer (LOP-P)
• Loss of signal (LOS)
• Payload label mismatch (PLM-P)
• Payload unequipped (unequipped STS at path level) (UNEQ-P)
• Remote defect indication—line (RDI-L)
• Remote defect indication—path (RDI-P)
• SDH alarms:
• Administrative unit alarm indication signal (AU-AIS)
• Bit error rate signal degrade (BERR-SD)
• Bit error rate signal fail (BERR-SF)
• Bit interleaved parity (BIP) error B1, B2, B3
• Higher order path—payload label mismatch (HP-PLM)
• Higher order path—loss of pointer (HP-LOP)
• Higher order path—remote defect indication (HP-RDI)
• Higher order path—unequipped (HP-UNEQ)
• Loss of frame (LOF)
• Loss of signal (LOS)
• Multiplex section—alarm indication signal (MS-AIS)
• Multiplex section—remote defect indication (MS-RDI)
• Multiplex section—remote error indication (MS-REI)
• Error detection:
• Errored seconds (ES-S, ES-L, ES-P)
• Far-end errored seconds (ES-LFE, ES-PFE)
• Far-end severely errored seconds (SES-LFE, SES-PFE)
• Far-end unavailable seconds (UAS-LFE, UAS-PFE)
Copyright © 2018, Juniper Networks, Inc.
159
T4000 Core Router Interface Module Reference
• Severely errored framing (SEF)
• Severely errored framing seconds (SEFS-S)
• Severely errored seconds (SES-S, SES-L, SES-P)
• Unavailable seconds (UAS-L, UAS-P)
Related
Documentation
• T4000 PIC Description
•
T4000 PICs Supported on page 3
SONET/SDH OC192/STM64 PICs with XFP (T4000 Router)
Figure 20: 1-Port SONET/SDH OC192/STM64 PIC Figure 21: 4-Port SONET/SDH OC192/STM64 PIC
•
•
•
•
Cables and Connectors on page 162
•
•
Alarms, Errors, and Events on page 163
Software Release
• 1-port: Junos OS Release 12.1R2 and later (Type 3)
160 Copyright © 2018, Juniper Networks, Inc.
Chapter 13: SONET/SDH PIC Descriptions
• 4-port: Junos OS Release 12.1 and later (Type 4)
For information on which FPCs support this PIC, see
“T4000 PIC/FPC Compatibility” on page 8 .
Hardware Features
• One or four OC192 ports
NOTE: Four OC192 links can be aggregated into one OC768 link or two
OC256 links. The four fiber links should be on the same fiber path or the same fiber.
• Power requirement:
• 1-port (Type 3): 0.52 A @ 48 V (25 W)
• 4-port (Type 4): 1.11 A @ 48 V (53.1 W)
• Model number for 1-port SONET/SDH OC192/STM64 PIC: PC-1OC192-SON-XFP
• Model number for 4-port SONET/SDH OC192/STM64 PIC: PD-4OC192-SON-XFP
• Multiplexing and demultiplexing
• Rate policing on input
• Rate shaping on output
• Packet buffering, Layer 2 parsing
Software Features
Table 88: Software Features Supported
Software Feature
T4000 First Supported
Junos OS Release for Type
3 PIC
T4000 First Supported
Junos OS Release for Type
4 PIC
Configuration of SONET or SDH framing on a per-port basis on the 4-port Type 4 PIC .
12.1R2
12.1R1
SONET/SDH framing
IEEE 802.3ad Link Aggregation
Alarm and event counting and detection
Dual-router automatic protection switching (APS)
Multiprotocol Label Switching (MPLS) fast reroute
12.1R2
12.1R2
12.1R2
12.1R2
12.1R2
12.1R1
12.1R1
12.1R1
12.1R1
12.1R1
Copyright © 2018, Juniper Networks, Inc.
161
T4000 Core Router Interface Module Reference
Table 88: Software Features Supported (continued)
Software Feature
Encapsulations:
•
•
•
•
•
Circuit cross-connect (CCC)
Translational cross-connect (TCC)
Frame Relay
High-Level Data Link Control (HDLC)
Point-to-Point Protocol (PPP)
T4000 First Supported
Junos OS Release for Type
3 PIC
T4000 First Supported
Junos OS Release for Type
4 PIC
12.1R2
12.1R1
Cables and Connectors
• Duplex LC connector (Rx and Tx)
• SONET/SDH OC192c/STM64 XFP transceivers:
• Short reach (SR-1) (model number: XFP-10G-L-OC192-SR1)
• Intermediate reach (IR-1) (model number: XFP-10G-E-OC192-IR2)
• Long reach (LR-1) (model number: XFP-10G-Z-OC192-LR2)
Optical interface specifications—see
“SONET/SDH OC192/STM64 Optical Interface
NOTE: To extend the life of the laser, when a PIC is not being actively used with any valid links, take the PIC offline until you are ready to establish a link to another device. For information about taking a PIC offline, see the request chassis pic offline command in request chassis pic.
LEDs
Table 89: 1-Port SONET/SDH OC192/STM64 PIC LEDs
Label Color State
LINK STATUS LED —
Green
Off
On steadily
Description
Port is down.
Port is online. Link is established.
162 Copyright © 2018, Juniper Networks, Inc.
Chapter 13: SONET/SDH PIC Descriptions
Table 90: 4-Port SONET/SDH OC192/STM64 PIC LEDs
Label Color State
Port LEDs labeled PORT
0 through
PORT 3 , one tricolor LED per port
—
Green
Yellow
Red
Off
On steadily
On steadily
On steadily
One 768 over
192 LED
—
Green
Yellow
Red
Off
On steadily
On steadily
On steadily
Description
Not enabled.
Online with no alarms or failures.
Online with alarms for remote failures.
Active with a local alarm; router has detected a failure.
Not enabled.
Online with no alarms or failures.
Online with alarms for remote failures.
Active with a local alarm; router has detected a failure.
Alarms, Errors, and Events
• SONET alarms:
• Alarm indication signal—line (AIS-L)
• Alarm indication signal—path (AIS-P)
• Bit error rate—signal degrade (BERR-SD)
• Bit error rate—signal fail (BERR-SF)
• Bit interleaved parity (BIP) error B1, B2, B3
• Far-end bit error: remote error indication—line (REI-L), far-end line coding violations
(CV-LFE)
• Far-end bit error: remote error indication—path (REI-P), far-end path coding violations
(CV-PFE)
• Loss of frame (LOF)
• Loss of pointer (LOP-P)
• Loss of signal (LOS)
• Payload label mismatch (PLM-P)
• Payload unequipped (unequipped STS at path level) (UNEQ-P)
• Remote defect indication—line (RDI-L)
• Remote defect indication—path (RDI-P)
• SDH alarms:
Copyright © 2018, Juniper Networks, Inc.
163
T4000 Core Router Interface Module Reference
• Administrative unit alarm indication signal (AU-AIS)
• Bit error rate signal degrade (BERR-SD)
• Bit error rate signal fail (BERR-SF)
• Bit interleaved parity (BIP) error B1, B2, B3
• Higher order path—payload label mismatch (HP-PLM)
• Higher order path—loss of pointer (HP-LOP)
• Higher order path—remote defect indication (HP-RDI)
• Higher order path—unequipped (HP-UNEQ)
• Loss of frame (LOF)
• Loss of signal (LOS)
• Multiplex section—alarm indication signal (MS-AIS)
• Multiplex section—remote defect indication (MS-RDI)
• Multiplex section—remote error indication (MS-REI)
• Error detection:
• Errored seconds (ES-S, ES-L, ES-P)
• Far-end errored seconds (ES-LFE, ES-PFE)
• Far-end severely errored seconds (SES-LFE, SES-PFE)
• Far-end unavailable seconds (UAS-LFE, UAS-PFE)
• Severely errored framing (SEF)
• Severely errored framing seconds (SEFS-S)
• Severely errored seconds (SES-S, SES-L, SES-P)
• Unavailable seconds (UAS-L, UAS-P)
Related
Documentation
• T4000 PIC Description
•
T4000 PICs Supported on page 3
164 Copyright © 2018, Juniper Networks, Inc.
SONET/SDH OC768c/STM256 PIC (T4000 Router)
Chapter 13: SONET/SDH PIC Descriptions
•
•
•
•
Cables and Connectors on page 166
•
•
Alarms, Errors, and Events on page 167
Software Release
Junos OS Release 12.1 and later (Type 4)
For information on which FPCs support this PIC, see
“T4000 PIC/FPC Compatibility” on page 8 .
Hardware Features
• One OC768 port
• Power requirement: 1.37 A @ 48 V (65.7 W)
• Model number: PD-1OC768-SON-SR
• Multiplexing and demultiplexing
• Rate policing on input
Copyright © 2018, Juniper Networks, Inc.
165
T4000 Core Router Interface Module Reference
• Rate shaping on output
• Packet buffering, Layer 2 parsing
Software Features
Table 91: Software Features Supported
Software Feature
SONET/SDH framing
IEEE 802.3ad Link Aggregation
Alarm and event counting and detection
Dual-router automatic protection switching (APS)
Multiprotocol Label Switching (MPLS) fast reroute
Layer 2 protocols:
•
•
•
•
•
Circuit cross-connect (CCC)
Translational cross-connect (TCC)
Frame Relay
High-Level Data Link Control (HDLC)
Point-to-Point Protocol (PPP)
Optical diagnostics and related alarms
•
•
•
•
Laser bias
Transmit optical power
Receiver optical power
Laser temperature
12.1
12.1
12.1
12.1
T4000 First Supported Junos
OS Release
12.1
12.1
12.1
Cables and Connectors
• Duplex SC connector (Rx and Tx)
• SONET/SDH OC768c/STM265 Short reach (SR-1) fixed transceiver
Optical interface specifications—see
“SONET/SDH OC768/STM256 Optical Interface
NOTE: To extend the life of the laser, when a PIC is not being actively used with any valid links, take the PIC offline until you are ready to establish a link to another device. For information about taking a PIC offline, see the request chassis pic offline command in request chassis pic.
166 Copyright © 2018, Juniper Networks, Inc.
Chapter 13: SONET/SDH PIC Descriptions
LEDs
Table 92: SONET/SDH OC768c/STM256 PIC LEDs
Label Color State
STATUS —
Green
Yellow
Red
Off
On steadily
On steadily
On steadily
Description
Not enabled.
Online with no alarms or failures.
Online with alarms for remote failures.
Active with a local alarm; router has detected a failure.
Alarms, Errors, and Events
• SONET alarms:
• Alarm indication signal—line (AIS-L)
• Alarm indication signal—path (AIS-P)
• Bit error rate—signal degrade (BERR-SD)
• Bit error rate—signal fail (BERR-SF)
• Bit interleaved parity (BIP) error B1, B2, B3
• Far-end bit error: remote error indication—line (REI-L), far-end line coding violations
(CV-LFE)
• Far-end bit error: remote error indication—path (REI-P), far-end path coding violations
(CV-PFE)
• Loss of frame (LOF)
• Loss of pointer (LOP-P)
• Loss of signal (LOS)
• Payload label mismatch (PLM-P)
• Payload unequipped (unequipped STS at path level) (UNEQ-P)
• Remote defect indication—line (RDI-L)
• Remote defect indication—path (RDI-P)
• SDH alarms:
• Administrative unit alarm indication signal (AU-AIS)
• Bit error rate signal degrade (BERR-SD)
• Bit error rate signal fail (BERR-SF)
• Bit interleaved parity (BIP) error B1, B2, B3
• Higher order path—payload label mismatch (HP-PLM)
Copyright © 2018, Juniper Networks, Inc.
167
T4000 Core Router Interface Module Reference
• Higher order path—loss of pointer (HP-LOP)
• Higher order path—remote defect indication (HP-RDI)
• Higher order path—unequipped (HP-UNEQ)
• Loss of frame (LOF)
• Loss of signal (LOS)
• Multiplex section—alarm indication signal (MS-AIS)
• Multiplex section—remote defect indication (MS-RDI)
• Multiplex section—remote error indication (MS-REI)
• Error detection:
• Errored seconds (ES-S, ES-L, ES-P)
• Far-end errored seconds (ES-LFE, ES-PFE)
• Far-end severely errored seconds (SES-LFE, SES-PFE)
• Far-end unavailable seconds (UAS-LFE, UAS-PFE)
• Severely errored framing (SEF)
• Severely errored framing seconds (SEFS-S)
• Severely errored seconds (SES-S, SES-L, SES-P)
• Unavailable seconds (UAS-L, UAS-P)
Related
Documentation
• T4000 PIC Description
•
T4000 PICs Supported on page 3
168 Copyright © 2018, Juniper Networks, Inc.
CHAPTER 14
End-of-Life PIC Descriptions
•
10-Gigabit Ethernet DWDM OTN EOL PIC (T4000 Router) on page 169
•
SONET/SDH OC12c/STM4 EOL PIC (T4000 Router) on page 171
•
SONET/SDH OC48c/STM16 EOL PICs (T4000 Router) on page 175
•
SONET/SDH OC48c/STM16 EOL PIC with SFP (T4000 Router) on page 179
•
SONET/SDH OC192/STM64 EOL PIC (T4000 Router) on page 182
10-Gigabit Ethernet DWDM OTN EOL PIC (T4000 Router)
•
•
•
•
Cables and Connectors on page 170
•
Software Release
Junos OS Release 12.1R2 and later (Type 3)
Copyright © 2018, Juniper Networks, Inc.
169
T4000 Core Router Interface Module Reference
For information on which FPCs support this PIC, see
“T4000 PIC/FPC Compatibility” on page 8 .
Hardware Features
• One 10-Gigabit Optical Transport Network (OTN) port for transport of 10-Gigabit
Ethernet (10GBASE-R) traffic
• Power requirement: 0.55 A @ 48 V (26.6 W)
• Supports large Ethernet frame sizes for more efficient throughput across the intra-POP network
• Model number: PC-1XGE-DWDM-OTN
• C-band ITU-Grid with 50 GHz spacing
• High-performance throughput at speeds up to 10 Gbps
• Full-duplex mode
• Maximum transmission units (MTUs) up to 9192 bytes
• 64 source MAC address filters
• 960 destination MAC filters
• 89 individual wavelengths
Software Features
Table 93: Software Features Supported
Software Feature
Enhanced optical monitoring capabilities
CLI configurable wavelength support
Virtual Router Redundancy Protocol (VRRP) support
802.1q virtual LANs (VLANs) support
IEEE 802.3ad Link Aggregation
RMON EtherStats
T4000 First Supported Junos OS Release
12.1R2
12.1R2
12.1R2
12.1R2
12.1R2
12.1R2
Cables and Connectors
• Duplex SC/PC connector (RX and TX)
• Fixed transceiver
• Dense wavelength division multiplexing (DWDM) optical transport network (OTN) transceiver.
170 Copyright © 2018, Juniper Networks, Inc.
Chapter 14: End-of-Life PIC Descriptions
Optical interface specifications—see
“10-Gigabit Ethernet DWDM OTN PIC
(PC-1XGE-DWDM-OTN) Optical Interface Specifications” on page 18
LEDs
Table 94: 10-Gigabit Ethernet DWDM OTN EOL PIC LEDs
Label Color State
Off STATUS LED, one bicolor
—
Green
Red
On steadily
On steadily
Description
PIC is not enabled.
PIC is operating normally.
PIC has an error or is in line-side loopback.
Related
Documentation
• T4000 PIC Description
•
T4000 PICs Supported on page 3
SONET/SDH OC12c/STM4 EOL PIC (T4000 Router)
Figure 22: 4-Port SONET/SDH OC12c/STM4 PIC
•
•
•
•
Cables and Connectors on page 172
•
•
Alarms, Errors, and Events on page 173
Software Release
Junos OS Release 12.2R2 and later (Type 2)
Copyright © 2018, Juniper Networks, Inc.
171
T4000 Core Router Interface Module Reference
For information on which FPCs support this PIC, see
“T4000 PIC/FPC Compatibility” on page 8 .
Hardware Features
• Four ports
• Power requirement: 0.23 A @ 48 V (10.8 W)
• Model number: PB-4OC12-SON-MM
• Model number: PB-4OC12-SON-SMIR
• Multiplexing and demultiplexing
• Rate policing on input
• Rate shaping on output
• Packet buffering, Layer 2 parsing
Software Features
Table 95: Software Features Supported
Software Feature
SONET/SDH framing
IEEE 802.3ad Link Aggregation
Alarm and event counting and detection
Dual-router automatic protection switching (APS)
Multiprotocol Label Switching (MPLS) fast reroute
Layer 2 protocols:
•
•
•
•
•
High-Level Data Link Control (HDLC)
Frame Relay
Circuit cross-connect (CCC)
Translational cross-connect (TCC)
Point-to-Point Protocol (PPP)
T4000 First Supported Junos OS
Release
12.2R2
12.2R2
12.2R2
12.2R2
12.2R2
12.2R2
Cables and Connectors
• Duplex SC connector (Rx and Tx)
• SONET/SDH OC12/STM4 fixed transceiver:
4-port: Multimode
4-port: Single-mode Intermediate reach (IR-1)
172 Copyright © 2018, Juniper Networks, Inc.
Chapter 14: End-of-Life PIC Descriptions
Optical interface specifications—see
“SONET/SDH OC12/STM4 Optical Interface
NOTE: To extend the life of the laser, when a PIC is not being actively used with any valid links, take the PIC offline until you are ready to establish a link to another device. For information about taking a PIC offline, see the request chassis pic offline command in request chassis pic.
LEDs
Table 96: SONET/SDH OC12c/STM4 EOL PIC LEDs
Label Color State
One tricolor per port
—
Green
Yellow
Red
Off
On steadily
On steadily
On steadily
Description
Not enabled.
Online with no alarms or failures.
Online with alarms for remote failures.
Active with a local alarm; router has detected a failure.
Alarms, Errors, and Events
• SONET alarms:
• Alarm indication signal—line (AIS-L)
• Alarm indication signal—path (AIS-P)
• Bit error rate signal degrade (BERR-SD)
• Bit error rate signal fail (BERR-SF)
• Bit interleaved parity (BIP) error B1
• Bit interleaved parity (BIP) error B2
• Bit interleaved parity (BIP) error B3
• Loss of frame (LOF)
• Loss of pointer (LOP-P)
• Loss of signal (LOS)
• Far-end bit error: remote error indication—line (REI-L) (CV-LFE)
• Far-end bit error: remote error indication—path (REI-P) (CV-PFE)
• Payload mismatch (path label mismatch) (PLM-P)
• Payload unequipped (unequipped STS at path level) (UNEQ-P)
Copyright © 2018, Juniper Networks, Inc.
173
T4000 Core Router Interface Module Reference
• Remote defect indication—line (RDI-L)
• Remote defect indication—path (RDI-P)
• SDH alarms:
• Multiplex section alarm indication signal (MS-AIS)
• Administrative unit alarm indication signal (AU-AIS)
• Bit error rate signal degrade (BERR-SD)
• Bit error rate signal fail (BERR-SF)
• Bit interleaved parity (BIP) error B1
• Bit interleaved parity (BIP) error B2
• Bit interleaved parity (BIP) error B3
• Loss of frame (LOF)
• Loss of pointer (HP-LOP)
• Loss of signal (LOS)
• Multiplex section remote error indication (MS-REI)
• Higher path label mismatch (HP-PLM)
• Higher path unequipped (HP-UNEQ)
• Multiplex section remote defect indication (MS-RDI)
• Higher path remote defect indication (HP-RDI)
• Errored seconds (ES-S, ES-L, ES-P), far-end errored seconds (ES-LFE, ES-PFE), far-end severely errored seconds (SES-LFE, SES-PFE), far-end unavailable seconds (UAS-LFE,
UAS-PFE)
• Severely errored framing (SEF), severely errored framing seconds (SEFS-S), severely errored seconds (SES-S, SES-L, SES-P), unavailable seconds (UAS-L, UAS-P)
Related
Documentation
• T4000 PIC Description
•
T4000 PICs Supported on page 3
174 Copyright © 2018, Juniper Networks, Inc.
Chapter 14: End-of-Life PIC Descriptions
SONET/SDH OC48c/STM16 EOL PICs (T4000 Router)
Figure 23: 1-Port SONET/SDH OC48c/STM16 PIC Figure 24: 4-Port SONET/SDH OC48c/STM16 PIC
•
•
•
•
Cables and Connectors on page 176
•
•
Alarms, Errors, and Events on page 177
Software Release
• 1-port: Junos OS Release 12.2R2 and later (Type 2)
• 4-port: Junos OS Release 12.1R2 and later (Type 3)
For information on which FPCs support this PIC, see
“T4000 PIC/FPC Compatibility” on page 8 .
Hardware Features
• One or four OC48 ports
• 1-port: 0.38 A @ 48 V (8 W)
• 4-port: 0.86 A @ 48 V (41.4 W)
• Model number for 1-port SONET/SDH OC48c/STM16 PIC: PB-1OC48-SON-SMSR
• Model number for 4-port SONET/SDH OC48c/STM16 PIC: PC-4OC48-SON-SMSR
• Multiplexing and demultiplexing
• Rate policing on input
• Rate shaping on output
• Packet buffering, Layer 2 parsing
Copyright © 2018, Juniper Networks, Inc.
175
T4000 Core Router Interface Module Reference
Software Features
Table 97: Software Features Supported
Software Feature
SONET/SDH framing
IEEE 802.3ad Link Aggregation
Alarm and event counting and detection
Dual-router automatic protection switching (APS)
Multiprotocol Label Switching (MPLS) fast reroute
Layer 2 protocols:
•
•
•
•
•
High-Level Data Link Control (HDLC)
Frame Relay
Circuit cross-connect (CCC)
Translational cross-connect (TCC)
Point-to-Point Protocol (PPP)
12.2R2
12.2R2
12.2R2
12.2R2
12.2R2
T4000 First Supported
Junos OS Release (Type 2)
T4000 First Supported
Junos OS Release (Type 3)
12.1R2
12.1R2
12.1R2
12.1R2
12.1R2
12.2R2
12.1R2
Cables and Connectors
• Duplex SC Connector (Rx and Tx)
• 1-port and 4-port: SONET/SDH OC48/STM16 fixed transceiver: short reach (SR-1)
• 1-port: Long reach (LR-1)
• Optical interface specifications—see
“SONET/SDH OC48/STM16 Optical Interface
NOTE: To extend the life of the laser, when a PIC is not being actively used with any valid links, take the PIC offline until you are ready to establish a link to another device. For information about taking a PIC offline, see the request chassis pic offline command in request chassis pic.
176 Copyright © 2018, Juniper Networks, Inc.
Chapter 14: End-of-Life PIC Descriptions
LEDs
Table 98: SONET/SDH OC48c/STM16 EOL PICs LEDs
Label Color
STATUS LED, one tricolor per port
—
Green
Yellow
Red
State
Off
On steadily
On steadily
On steadily
Alarms, Errors, and Events
• SONET alarms:
• Alarm indication signal—line (AIS-L)
• Alarm indication signal—path (AIS-P)
• Bit error rate signal degrade (BERR-SD)
• Bit error rate signal fail (BERR-SF)
• Bit interleaved parity (BIP) error B1
• Bit interleaved parity (BIP) error B2
• Bit interleaved parity (BIP) error B3
• Loss of frame (LOF)
• Loss of pointer (LOP-P)
• Loss of signal (LOS)
• Far-end bit error: remote error indication—line (REI-L) (CV-LFE)
• Far-end bit error: remote error indication—path (REI-P) (CV-PFE)
• Payload mismatch (path label mismatch) (PLM-P)
• Payload unequipped (unequipped STS at path level) (UNEQ-P)
• Remote defect indication—line (RDI-L)
• Remote defect indication—path (RDI-P)
• SDH alarms:
• Multiplex section alarm indication signal (MS-AIS)
• Administrative unit alarm indication signal (AU-AIS)
• Bit error rate signal degrade (BERR-SD)
Description
Not enabled.
Online with no alarms or failures.
Online with alarms for remote failures.
Active with a local alarm; router has detected a failure.
Copyright © 2018, Juniper Networks, Inc.
177
T4000 Core Router Interface Module Reference
• Bit error rate signal fail (BERR-SF)
• Bit interleaved parity (BIP) error B1
• Bit interleaved parity (BIP) error B2
• Bit interleaved parity (BIP) error B3
• Loss of frame (LOF)
• Loss of pointer (HP-LOP)
• Loss of signal (LOS)
• Multiplex section remote error indication (MS-REI)
• Higher path label mismatch (HP-PLM)
• Higher path unequipped (HP-UNEQ)
• Multiplex section remote defect indication (MS-RDI)
• Higher path remote defect indication (HP-RDI)
• Errored seconds (ES-S, ES-L, ES-P), far-end errored seconds (ES-LFE, ES-PFE), far-end severely errored seconds (SES-LFE, SES-PFE), far-end unavailable seconds (UAS-LFE,
UAS-PFE)
• Severely errored framing (SEF), severely errored framing seconds (SEFS-S), severely errored seconds (SES-S, SES-L, SES-P), unavailable seconds (UAS-L, UAS-P)
Related
Documentation
• T4000 PIC Description
•
T4000 PICs Supported on page 3
178 Copyright © 2018, Juniper Networks, Inc.
Chapter 14: End-of-Life PIC Descriptions
SONET/SDH OC48c/STM16 EOL PIC with SFP (T4000 Router)
•
•
•
•
Cables and Connectors on page 180
•
•
Alarms, Errors, and Events on page 181
Software Release
Junos OS Release 12.2R2 and later (Type 2)
For information on which FPCs support this PIC, see
“T4000 PIC/FPC Compatibility” on page 8 .
Hardware Features
• One OC48 port
• Power requirement: 0.33 A @ 48 V (16 W)
• Model number: PB-1OC48-SON-SFP
• Multiplexing and demultiplexing
• Rate policing on input
• Rate shaping on output
• Packet buffering, Layer 2 parsing
Copyright © 2018, Juniper Networks, Inc.
179
T4000 Core Router Interface Module Reference
Software Features
Table 99: Software Features Supported
Software Feature
SONET/SDH framing
IEEE 802.3ad Link Aggregation
Alarm and event counting and detection
Dual-router automatic protection switching (APS)
Multiprotocol Label Switching (MPLS) fast reroute
Layer 2 protocols:
•
•
•
•
•
High-Level Data Link Control (HDLC)
Frame Relay
Circuit cross-connect (CCC)
Translational cross-connect (TCC)
Point-to-Point Protocol (PPP)
T4000 First Supported Junos OS
Release
12.2R2
12.2R2
12.2R2
12.2R2
12.2R2
12.2R2
Cables and Connectors
• Duplex LC Connector (Rx and Tx)
• SONET/SDH OC48/STM16 fiber-optic SFP transceivers:
• Short reach (SR-1) (model number: SFP-1OC48-SR)
• Intermediate reach (IR-1) (model number: SFP-1OC48-IR)
• Long reach (LR-1) (model number: SFP-1OC48-LR)
Optical interface specifications—see
“SONET/SDH OC48/STM16 Optical Interface
NOTE: To extend the life of the laser, when a PIC is not being actively used with any valid links, take the PIC offline until you are ready to establish a link to another device. For information about taking a PIC offline, see the request chassis pic offline command in request chassis pic.
180 Copyright © 2018, Juniper Networks, Inc.
Chapter 14: End-of-Life PIC Descriptions
LEDs
Table 100: SONET/SDH OC48c/STM16 EOL PIC with SFP LEDs
Label Color State Description
One tricolor per port
—
Green
Yellow
Red
Off
On steadily
On steadily
On steadily
Not enabled
Online with no alarms or failures
Online with alarms for remote failures
Active with a local alarm; router has detected a failure
Alarms, Errors, and Events
• SONET alarms:
• Alarm indication signal—line (AIS-L)
• Alarm indication signal—path (AIS-P)
• Bit error rate signal degrade (BERR-SD)
• Bit error rate signal fail (BERR-SF)
• Bit interleaved parity (BIP) error B1
• Bit interleaved parity (BIP) error B2
• Bit interleaved parity (BIP) error B3
• Loss of frame (LOF)
• Loss of pointer (LOP-P)
• Loss of signal (LOS)
• Far-end bit error: remote error indication—line (REI-L) (CV-LFE)
• Far-end bit error: remote error indication—path (REI-P) (CV-PFE)
• Payload mismatch (path label mismatch) (PLM-P)
• Payload unequipped (unequipped STS at path level) (UNEQ-P)
• Remote defect indication—line (RDI-L)
• Remote defect indication—path (RDI-P)
• SDH alarms:
• Multiplex section alarm indication signal (MS-AIS)
• Administrative unit alarm indication signal (AU-AIS)
• Bit error rate signal degrade (BERR-SD)
• Bit error rate signal fail (BERR-SF)
Copyright © 2018, Juniper Networks, Inc.
181
T4000 Core Router Interface Module Reference
• Bit interleaved parity (BIP) error B1
• Bit interleaved parity (BIP) error B2
• Bit interleaved parity (BIP) error B3
• Loss of frame (LOF)
• Loss of pointer (HP-LOP)
• Loss of signal (LOS)
• Multiplex section remote error indication (MS-REI)
• Higher path label mismatch (HP-PLM)
• Higher path unequipped (HP-UNEQ)
• Multiplex section remote defect indication (MS-RDI)
• Higher path remote defect indication (HP-RDI)
• Errored seconds (ES-S, ES-L, ES-P), far-end errored seconds (ES-LFE, ES-PFE), far-end severely errored seconds (SES-LFE, SES-PFE), far-end unavailable seconds (UAS-LFE,
UAS-PFE)
• Severely errored framing (SEF), severely errored framing seconds (SEFS-S), severely errored seconds (SES-S, SES-L, SES-P), unavailable seconds (UAS-L, UAS-P)
Related
Documentation
• T4000 PIC Description
•
T4000 PICs Supported on page 3
SONET/SDH OC192/STM64 EOL PIC (T4000 Router)
182
•
•
•
•
Cables and Connectors on page 184
Copyright © 2018, Juniper Networks, Inc.
Chapter 14: End-of-Life PIC Descriptions
•
•
Alarms, Errors, and Events on page 184
Software Release
Junos OS Release 12.1R2 and later (Type 3)
Hardware Features
• One OC192 port
• Power requirement: 0.45 A @ 48 V (21.6 W)
• Model number: PC-1OC192-SON-SR2
• Multiplexing and demultiplexing
• Rate policing on input
• Rate shaping on output
• Packet buffering, Layer 2 parsing
Software Features
Table 101: Software Features Supported
Software Feature
SONET/SDH framing
IEEE 802.3ad Link Aggregation
Alarm and event counting and detection
Dual-router automatic protection switching (APS)
Multiprotocol Label Switching (MPLS) fast reroute
Layer 2 protocols:
•
•
•
•
•
High-Level Data Link Control (HDLC)
Frame Relay
Circuit cross-connect (CCC)
Translational cross-connect (TCC)
Point-to-Point Protocol (PPP)
T4000 First Supported Junos OS
Release
12.1R2
12.1R2
12.1R2
12.1R2
12.1R2
12.1R2
Copyright © 2018, Juniper Networks, Inc.
183
T4000 Core Router Interface Module Reference
Cables and Connectors
SONET/SDH OC192/STM64 fixed transceiver: Short reach (SR-2): duplex SC connector
(Rx and Tx)
• Optical interface specifications—see
“SONET/SDH OC192/STM64 Optical Interface
NOTE: To extend the life of the laser, when a PIC is not being actively used with any valid links, take the PIC offline until you are ready to establish a link to another device. For information about taking a PIC offline, see the request chassis pic offline command in request chassis pic.
LEDs
Table 102: SONET/SDH OC192/STM64 EOL PIC LEDs
Label Color State
STATUS LED, one tricolor
—
Green
Yellow
Red
Off
On steadily
On steadily
On steadily
Description
Not enabled
Online with no alarms or failures
Online with alarms for remote failures
Active with a local alarm; router has detected a failure
Alarms, Errors, and Events
• SONET alarms:
• Alarm indication signal—line (AIS-L)
• Alarm indication signal—path (AIS-P)
• Bit error rate signal degrade (BERR-SD)
• Bit error rate signal fail (BERR-SF)
• Bit interleaved parity (BIP) error B1
• Bit interleaved parity (BIP) error B2
• Bit interleaved parity (BIP) error B3
• Loss of frame (LOF)
• Loss of pointer (LOP-P)
• Loss of signal (LOS)
• Far-end bit error: remote error indication—line (REI-L) (CV-LFE)
• Far-end bit error: remote error indication—path (REI-P) (CV-PFE)
184 Copyright © 2018, Juniper Networks, Inc.
Chapter 14: End-of-Life PIC Descriptions
• Payload mismatch (path label mismatch) (PLM-P)
• Payload unequipped (unequipped STS at path level) (UNEQ-P)
• Remote defect indication—line (RDI-L)
• Remote defect indication—path (RDI-P)
• SDH alarms:
• Multiplex section alarm indication signal (MS-AIS)
• Administrative unit alarm indication signal (AU-AIS)
• Bit error rate signal degrade (BERR-SD)
• Bit error rate signal fail (BERR-SF)
• Bit interleaved parity (BIP) error B1
• Bit interleaved parity (BIP) error B2
• Bit interleaved parity (BIP) error B3
• Loss of frame (LOF)
• Loss of pointer (HP-LOP)
• Loss of signal (LOS)
• Multiplex section remote error indication (MS-REI)
• Higher path label mismatch (HP-PLM)
• Higher path unequipped (HP-UNEQ)
• Multiplex section remote defect indication (MS-RDI)
• Higher path remote defect indication (HP-RDI)
• Errored seconds (ES-S, ES-L, ES-P), far-end errored seconds (ES-LFE, ES-PFE), far-end severely errored seconds (SES-LFE, SES-PFE), far-end unavailable seconds (UAS-LFE,
UAS-PFE)
• Severely errored framing (SEF), severely errored framing seconds (SEFS-S), severely errored seconds (SES-S, SES-L, SES-P), unavailable seconds (UAS-L, UAS-P)