Rigol USB-GPIB Adapter User Manual


Add to my manuals
15 Pages

advertisement

Rigol USB-GPIB Adapter User Manual | Manualzz

User’s Guide

  RIGOL

Publication Number UG-080318

March 2008

USB-GPIB 适配器

USB-GPIB Adapter

 

Copyright ©1998-2008 RIGOL Technologies, Inc. All Rights Reserved

RIGOL   

Copyright ©1998-2008 RIGOL Technologies, Inc. All Rights

Reserved. z RIGOL products are protected by patent law in and out of P.R. China. z Information in this publication replaces that in all previously corresponding material. z RIGOL Technologies, Inc. reserves the right to modify or change part of or all the specifications and pricing policies at company’s sole decision.

NOTE:

RIGOL

is registered trademark of

RIGOL

TECHNOLOGIES,

INC.

Copyright ©1998-2008 RIGOL Technologies, Inc.

1

User’s Guide for USB-GPIB Adapter

 

RIGOL  

Safety Notices

 

Review the following safety precautions carefully before operating the module to avoid any personal injuries or damages to the module and any products connected to it.

To avoid potential hazards, use the module as specified by this user’s guide only.

The instrument should be serviced by qualified personnel only.

To Avoid Fire or Personal Injury.

Connect and Disconnect Accessories. Do not connect or disconnect cables in running state.

 

2                                 Copyright ©1998-2008 RIGOL Technologies, Inc.

User’s Guide for USB-GPIB Adapter

 

RIGOL   

Do Not Operate Without Covers. Do not operate the module with covers or panels removed.

 

Avoid Circuit or Wire Exposure. Do not touch exposed connections and components when power is on.

 

Do Not Operate With Suspected Failures. If suspected damage occurs with the instrument, have it inspected by

RIGOL authorized service personnel before further operations.

Do Not Operate in Wet/Damp Conditions.

Do Not Operate in an Explosive Environment.

Keep Product Surfaces Clean and Dry.

 

Copyright ©1998-2008 RIGOL Technologies, Inc.

3

User’s Guide for USB-GPIB Adapter

 

RIGOL  

RIGOL

USB-GPIB Adapter Introduction

RIGOL USB-GPIB Adapter used for RIGOL instrument with

USB Host interface but without GPIB interface (for example

DS1000 series oscilloscopes) connects to a GPIB controller. It is also a module that expands the GPIB interface for RIGOL   instrument without GPIB interface, and enables the RIGOL instrument to be easier to work through GPIB interface.

RIGOL USB-GPIB Adapter gives you: z Enable GPIB control of

RIGOL instruments through the

USB Host port of RIGOL instruments. z GPIB primary address of RIGOL instrument is assignable through the host instrument. z Powered by USB Host, do not need the external power supply.

4                                 Copyright ©1998-2008 RIGOL Technologies, Inc.

User’s Guide for USB-GPIB Adapter

 

z LED indicator provides power status.

RIGOL   

Copyright ©1998-2008 RIGOL Technologies, Inc.

5

User’s Guide for USB-GPIB Adapter

 

RIGOL  

Connection of the Adapter

Connect the USB interface of the adapter to the USB Host interface of the RIGOL instrument and connect the GPIB interface of the adapter to the GPIB bus controller.

LED   Power   Indicator  

Controller GPIB USB

RIGOL   Instrument  

USB-GPIB configuration of controller and instrument

Note:

This adapter is used for the RIGOL USB Host interface and connects to the GPIB bus controller. Cannot connect reverse. Please pay attention to the connection method.

6                                 Copyright ©1998-2008 RIGOL Technologies, Inc.

User’s Guide for USB-GPIB Adapter

 

RIGOL   

GPIB primary address of RIGOL instrument is assignable through the host instrument, the default GPIB primary address is 16.

Copyright ©1998-2008 RIGOL Technologies, Inc.

7

User’s Guide for USB-GPIB Adapter

 

RIGOL  

System Request

Each adapter controls one instrument and does not support use of USB hubs.

Attention

May access LED Power Indicator gain the power supply information of the Adapter. After connecting and starting the instrument correctly, the LED Power Indicator of the adapter is not bright, please contact the RIGOL to confirm the malfunction. Please do not disassemble the Adapter yourself.

8                                 Copyright ©1998-2008 RIGOL Technologies, Inc.

User’s Guide for USB-GPIB Adapter

 

RIGOL   

Service & Support

Warranty (USB-GPIB Adapter)

RIGOL Technologies, Inc. warrants its products’ mainframe and accessories in materials and technics within the warranty period. During the period concerned, RIGOL guarantees the free replacement or repair of products which are approved defective.

To get repair service or obtain a copy of the whole warranty statement, please contact the RIGOL sales and service office.

RIGOL do not provide any other warranty item except the one being provided by this summary and the warranty statement. The warranty items include but not being subjected to the hint guarantee items related to tradable

Copyright ©1998-2008 RIGOL Technologies, Inc.

9

User’s Guide for USB-GPIB Adapter

 

RIGOL   characteristic and any particular purpose.

RIGOL will not take any responsibility in cases regarding to indirect, particular and ensuing damage.

10                                 Copyright ©1998-2008 RIGOL Technologies, Inc.

User’s Guide for USB-GPIB Adapter

 

RIGOL   

Service & Support

RIGOL has a professional and enthusiastic service and support team, to solve the technical problems in the application and provide the application solutions and product training service. z Maintenance service: You can get the maintenance free of charge during the warranty period. RIGOL suggests you purchase the Value Added Maintenance Service Plan to extend the warranty period and enjoy the overflow benefit. z Calibration service: You can apply for calibration service of RIGOL products, ensuring the instruments keeps the high performance. RIGOL suggests you purchase the

Value Added Calibration Service Plan, in order to enjoy the more economic calibration service.

Copyright ©1998-2008 RIGOL Technologies, Inc.

11

User’s Guide for USB-GPIB Adapter

 

RIGOL   z Quick service: RIGOL promises product maintenance and calibration service accomplished within five working days and makes effort to reduce inconvenience caused by maintenance or calibration. RIGOL suggests you to purchase the Value Added Quick Service Plan, to enjoy the fastest maintenance achieved within 2 hours and

24-hour calibration service.

RIGOL also provides you the quotation service, technical support, application solutions and system integration service.

12                                 Copyright ©1998-2008 RIGOL Technologies, Inc.

User’s Guide for USB-GPIB Adapter

 

RIGOL   

Contact

RIGOL

If you have any problem or requirement when using our products, please contact RIGOL Technologies, Inc. or your local distributors.

Domestic: Please call

Tel: (86-10) 8070 6688

Fax: (86-10) 8070 5070

Service & Support Hotline: 800 810 0002

9:00 am –5: 00 pm from Monday to Friday

Or e-mail to:

[email protected]

Or mail to: RIGOL Technologies, Inc.

156# CaiHe Village, ShaHe Town, ChangPing District,

Beijing, China

Post Code: 102206

Overseas: Contact local RIGOL distributors or sales office.

For the latest product information and service, please visit our website: http://www.rigolna.com

Copyright ©1998-2008 RIGOL Technologies, Inc.

13

User’s Guide for USB-GPIB Adapter

 

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

advertisement