SmartZone
™
G5 Basic & Intelligent
Power Distribution Units (iPDUs) for Japan
S P E C I F I C A T I O N S H E E T o v e r v i e w
The Panduit ™ SmartZone ™ G5 Basic & Intelligent Power Distribution Units are more than a power distribution unit and energy meter. These iPDUs monitor the data center power and environment (at the rack or cabinet level), by continuously scanning for electrical circuit overloads, and physical environmental conditions that place critical IT equipment at risk. Panduit’s iPDUs provide comprehensive, accurate, energy measurement data to efficiently use power resources, make informed capacity planning decisions, improve uptime, measure PUE (power usage effectiveness), and drive green data center initiatives to save energy and money.
Making the right choice in IT equipment is essential for a safe, efficient data center operation. Our full range of iPDUs, environmental sensors, and dual locking power cords are the key to fulfilling missionâcritical data center needs.
t e c h n i c a l i n f o r m a t i o n
Dimensions:
Mounting:
1U:
1U:
1U:
2U:
0U FULL:
Height Inch (mm)
1.6 (40.6)
1.7 (43.2)
1.7 (43.2)
3.4 (86.4)
68.9 (1750.1)
Width Inch (mm)
17.5 (444.5)
17.5 (444.5)
17.5 (444.5)
17.5 (444.5)
2.0 (50.8)
Depth Inch (mm)
2.0 (50.8)
7.8 (198.1)
10.6 (269.2)
7.8 (198.1)
2.1 (53.3)
0U Full Wide:
0U Full Wide +:
68.9 (1750.1)
74.0 (1880)
3.3 (83.8)
3.3 (83.8)
2.1 (53.3)
2.1 (53.3)
Vertical units provide up to 54 outlets and without encroaching on the EIA space.
Horizontal units provide up to 16 outlets and mount in standard.
(1U or 2U) TIA/EIA rack space.
k e y f e a t u r e s a n d b e n e f i t s ( i P D U s )
HotSwappable
Controller
Redundant Network
Access
Hardened Security
1GB Ethernet
Plug & Play Sensors
Multi-Color PDUs
Mobile & Desktop
Friendly Web GUI
Replace the controller and display module without having to power down the rack
Specifically designed for Landlord/Tenant (Co-Lo’s) allowing for remote access of real-time, vital statistics and operating information on two separate, secure networks
Not only Physical but hardened Digital Security; layers within the firmware LDAP,
SNMP v3, TLS, Encrypted Security; allows for Panduit PDUs to pass standard certified security scans
The 1G controller is compatible with the new Data Center Network switches being deployed - reducing special network configurations/resources required to support the iPDU
Digital sensors not only allow for multiple sensors on the same bus; but also identify themselves to the controller to simplify setup and commissioning.
Different color PDUs simplify power feed identification and management.
The new Panduit Intelligent PDUs are available in Black, White, Red, Blue,
Yellow, or Green.
The intelligent PDUs feature an enhanced designed web interface which detects the type of device that you are on; and automatically adjusts the screen for an optimal experience
Meets demands of densely packed IT equipment in rack or cabinet space Outlet Density
Form Factor Optimal form factor enables efficient rack space utilization
Operating Temperature 60°C ambient at full load for operational reliability in high temperature areas
(continued pg. 2) www.panduit.com
SmartZone ™ G5 Basic & Intelligent Power Distribution Units (iPDUs) for Japan k e y f e a t u r e s a n d b e n e f i t s ( i P D U s )
(continued)
Cable Retention
Circuit Breakers
Innovative cable tie accepting outlets allow for secure cord retention (C13 & C19 only) using a cable tie for added safety and security. (Panduit part number: PLT2I-C0)
Protects data center equipment for increased reliability by interrupting potentially hazardous circuit over-current conditions*
Color Coded Circuits* Easily identify phase to outlet banks to aid in fault isolation or load balancing
External Chassis
Ground
Meets NEC requirements and installation guidelines for IT equipment
Load Balancing
Multiple Input Plug
Options
Monitored through visual display on oLED (for 3 phase units only)
A full breadth offering to seamlessly interoperate with existing building power wiring schemes
Multiple Mounting
Options
Mounting Buttons
Supported Metering
Enables simple out of the box commissioning and flexibility with Panduit cabinets and industry standard mounting features enabling installation into third party cabinets
Allows tool-less mounting of rack PDUs for faster installations on vertical 0U units
Frequency, VA, PF, plus aggregate and per phase Amperage, Voltage, Wattage, and Kilowatts per hour
*Applies to products outfitted with circuit breakers
P D U p r o d u c t f a m i l i e s
Basic Series:
MI Series:
MS Series:
MPO Series:
MSPO Series:
Non Networked Rack PDUs provide reliable and cost effective power distribution in a variety of inputs (Single or Three Phase) and outlet configurations (IEC C13, C19, or 5-20R).
Rack PDUs that have the ability for aggregate power monitoring to quickly identify potential power issues, and reclaim available or under-utilized power capacity.
Rack PDUs that have the ability for aggregate power monitoring and outlet level switching capabilities for individual outlets or a group of outlets. Enabling power sequencing, rebooting equipment or restrict unauthorized use of individual outlets.
Rack PDUs that have the ability for outlet level (and aggregate) power monitoring to quickly identify potential power issues, and reclaim available or under-utilized power capacity at the outlet level enabling the redeployment or decommissioning of individual servers to reclaim available or under-utilized power capacity.
Rack PDUs that have the ability for outlet level (and aggregate) power monitoring and outlet level switching capabilities for individual outlets or a group of outlets. Power monitoring at the individual outlet level provides actionable management data on the power consumption of each connected IT device enabling the redeployment or decommissioning of individual servers to reclaim available or under-utilized power capacity. Ideal for remote power reset, and cabinet power on sequencing and restrict unauthorized use of individual outlets.
e l e c t r i c a l s p e c i f i c a t i o n s
Input Voltage:
Input Current:
(per phase)
Input Power:
Input Frequency:
Output Voltage:
Maximum output: current (outlet)
Overload protection:
(where applicable)
JAPAN
• Single-Phase 100V
• Single-Phase 200V
• Three-Phase 200V
• Three-Phase 415V
JAPAN
• 16A, 20A, 30A, 32A, 60A
JAPAN
• 1.9 – 22.0 (kVA)
50/60 Hz
100VAC, 200VAC, 240VAC
IEC C13: 10A
IEC C19: 16A
NEMA 5-20R: 16A
Circuit Breakers, hydraulic magnetic
Input Cord Length: 10 ft. (3m) unless otherwise specified www.panduit.com
SmartZone ™ G5 Basic & Intelligent Power Distribution Units (iPDUs) for Japan g e n e r a l s p e c i f i c a t i o n s
Temperature:
Operating
10°C to 60°C (50°F to 140°F)
-20°C to 60°C (-4°F to 140°F) Temperature:
Storage
Relative Humidity:
Operating
Relative Humidity:
Non-Operating
Relative Humidity:
Storage
10% to 90% non-condensing
5% to 95% RH
5% to 95%
Elevation:
Operating
Elevation:
Storage
Conformance
Standards:
Environmental
Compliances:
0 to 10,000 ft. (0 to 3000m)
0 to 30,000 ft. (0 to 9144m)
PSE Compliant: PDUs ≤ 50A or ≤ 300V
UL File number: E218078
PSE Exempt: PDUs > 50A or > 300V
RoHS & REACH c a b i n e t c o m p a t i b i l i t y
Panduit iPDUs can be easily installed into Panduit (or third party cabinets) by utilizing the installed mounting buttons
(18.4 mm diameter). Where necessary, a Small Diameter (14.5 mm) mounting button is available (sold separately,
P/N: MA018). Panduit PDUs feature threaded inserts on the back and both sides for the ultimate in mounting flexibility.
They safely and efficiently manage and distribute power to multiple devices through a single input power connector, per PDU, to enhance scalability of network build outs.
www.panduit.com
SmartZone ™ G5 Basic & Intelligent Power Distribution Units (iPDUs) for Japan
Basic Series
Region
JPN
JPN
JPN
JPN
JPN
JPN
JPN
JPN
JPN
JPN
JPN
JPN
JPN
JPN
Form Factor
1U
1U
1U
0U HALF
2U
0U HALF
0U HALF
0U HALF
0U HALF
0U HALF
0U MID
0U MID
0U MID
1U
Input Plug Type
NEMA L5-20P
NEMA L6-20P
NEMA L6-30P
NEMA L5-20P
NEMA L5-30P
NEMA L6-30P
NEMA L5-20P
NEMA L5-30P
NEMA L6-20P
NEMA L5-30P
NEMA L6-30P
NEMA L6-30P
NEMA L6-30P
IEC 60309 3P+E 9h 60A (IP44)
Input
Voltage
Range
Input
Current per phase
100VAC 20
100-200VAC 20
200VAC
100VAC
30
20
Circuit
Breakers
0
0
2
0
100VAC
200VAC
100VAC
100VAC
30
30
20
30
100-200VAC 20
100VAC
200VAC
200VAC
200VAC
200VAC
30
30
30
30
60
2
2
2
2
6
0
2
2
2
0
Apparent
Power
(kVA)
1.9 kVA
3.3 kVA
5.0 kVA
1.9 kVA
2.9 kVA
5.0 kVA
1.9 kVA
2.9 kVA
3.3 kVA
2.9 kVA
5.0 kVA
5.0 kVA
5.0 kVA
17.3 kVA
22
24
42
42
6
16
20
22
22
22
Outlet
Count
12
12
12
16
(12)5-20R
(12)C13
(12)C13
(16)5-20R
Outlet
Type
(16)5-20R
(20)C13
(20)C13, (2)C19
(22)5-20R
(20)C13, (2)C19
(22)5-20R
(20)C13, (4)C19
(36)C13, (6)C19
(36)C13, (6)C19
(6)C19
JPN
JPN
JPN
JPN
JPN
JPN
JPN
JPN
JPN
JPN
0U FULL
1U
0U HALF
0U MID
0U FULL
0U FULL
1U
0U FULL
0U MID
0U FULL
IEC 60309 3P+E 9h 60A (IP44)
NEMA L15-30P
NEMA L15-30P
NEMA L15-30P
NEMA L15-30P
200VAC
200VAC
200VAC
200VAC
200VAC
IEC 60309 3P+N+E 6h 16A (IP44) 200VAC
IEC 60309 3P+N+E 6h 32A (IP44) 200VAC
IEC 60309 3P+N+E 6h 32A (IP44) 200VAC
IEC 60309 3P+N+E 6h 16A (IP44) 200VAC
IEC 60309 3P+N+E 6h 32A (IP44) 200VAC
60
30
30
30
30
60
30
30
30
30
3
3
6
3
3
3
3
6
3
3
8.6 kVA
8.6 kVA
8.6 kVA
8.6 kVA
11.0 kVA
8.6 kVA
8.6 kVA
8.6 kVA
8.6 kVA
11.0 kVA
24
30
6
6
42
24
6
18
36
42
(12)C13, (12)C19
(6)C19
(18)C13
(30)C13, (6)C19
(36)C13, (6)C19
(6)C19
(6)C19
(12)C13, (12)C19
(24)13, (6)C19
(30)C13, (12)C19
JPN
JPN
JPN
JPN
0U MID
1U
0U FULL
0U FULL
JPN 0U FULL - Wide
IEC 60309 3P+N+E 6h 16A (IP44) 415VAC
NEMA L22-30P
NEMA L22-30P
NEMA L22-30P
NEMA L22-30P
415VAC
415VAC
415VAC
415VAC
30
50
60
30
30
0
6
6
0
6
22.0 kVA
11.0 kVA
22.0 kVA
11.0 kVA
17.3 kVA
42
6
24
36
48
(36)C13, (6)C19
(6)C19
(12)C13, (12)C19
(24)C13, (12)C19
(48)C13
JPN 0U FULL - Wide NEMA L22-30P 415VAC 30 0 17.3 kVA 54 (48)C13, (6)C19
Note: Minimum Order Quantity: 30 Pieces Per Part Number, Lead Time: 45 Business Days, Terms: Non-Cancellable / Non-Returnable
Monitored Input (MI Series)
Region
JPN
JPN
JPN
JPN
JPN
JPN
JPN
JPN
JPN
JPN
JPN
JPN
JPN
JPN
JPN
JPN
JPN
JPN
JPN
JPN
JPN
Form Factor
1U
1U
2U
2U
0U HALF
0U MID
0U MID
0U MID
0U MID
0U FULL
0U FULL
1U
0U FULL
1U
0U MID
0U FULL
1U
1U
0U FULL
0U MID
0U FULL
Input Plug Type
NEMA L5-20P
NEMA L6-20P
NEMA L5-30P
NEMA L6-30P
NEMA L5-20P
NEMA L6-30P
NEMA L5-30P
NEMA L6-20P
NEMA L5-30P
NEMA L6-30P
NEMA L6-30P
Input
Voltage
Range
100VAC
IEC 60309 3P+E 9h 60A (IP44)
IEC 60309 3P+E 9h 60A (IP44)
NEMA L15-30P
NEMA L15-30P
NEMA L15-30P
200VAC
200VAC
200VAC
200VAC
200VAC
IEC 60309 3P+N+E 6h 16A (IP44) 415VAC
IEC 60309 3P+N+E 6h 32A (IP44) 415VAC
IEC 60309 3P+N+E 6h 32A (IP44) 415VAC
IEC 60309 3P+N+E 6h 16A (IP44) 415VAC
IEC 60309 3P+N+E 6h 32A (IP44) 415VAC
Input
Current per phase
20
100-200VAC 20
100VAC 30
200VAC
100VAC
200VAC
30
20
30
100VAC 30
100-200VAC 20
100VAC
200VAC
200VAC
30
30
30
16
32
32
16
32
60
60
30
30
30
Circuit
Breakers
0
2
2
2
0
2
2
0
0
2
2
6
0
0
6
6
3
3
6
6
3
Apparent
Power
(kVA)
1.9 kVA
3.3 kVA
2.9 kVA
5.0 kVA
1.9 kVA
5.0 kVA
2.9 kVA
3.3 kVA
2.9 kVA
5.0 kVA
5.0 kVA
17.3 kVA
17.3 kVA
8.6 kVA
8.6 kVA
8.6 kVA
11.0 kVA
22.0 kVA
22.0 kVA
11.0 kVA
22.0 kVA
Outlet
Count
8
12
16
16
16
24
24
24
24
38
38
24
30
6
6
42
6
24
6
24
36
(8)5-20R
(12)C13
(16)5-20R
Outlet
Type
(12)C13, (4)C19
(16)5-20R
(20)C13, (4)C19
(24)5-20R
(20)C13, (4)C19
(24)5-20R
(32)C13, (6)C19
(32)C13, (6)C19
(6)C19
(12)C13, (12)C19
(6)C19
(18)C13, (6)C19
(30)C13, (6)C19
(6)C19
(6)C19
(12)C13, (12)C19
(24)C13, (6)C19
(30)C13, (12)C19
JPN
JPN
JPN
JPN
0U FULL
1U
0U FULL
0U FULL
JPN 0U FULL - Wide
IEC 60309 3P+N+E 6h 16A (IP44) 415VAC
NEMA L22-30P
NEMA L22-30P
NEMA L22-30P
NEMA L22-30P
415VAC
415VAC
415VAC
415VAC
16
30
30
30
30
0
6
6
6
6
11.0 kVA
17.3 kVA
17.3 kVA
17.3 kVA
17.3 kVA
42
6
24
36
48
(36)C13, (6)C19
(6)C19
(12)C13, (12)C19
(24)C13, (12)C19
(48)C13
JPN 0U FULL + NEMA L22-30P 415VAC 30 6 17.3 kVA 42 (36)C13, (6)C19
Note: Minimum Order Quantity: 30 Pieces Per Part Number, Lead Time: 45 Business Days, Terms: Non-Cancellable / Non-Returnable
Output
Voltage
Panduit
Part Number
100 P12BF6M-BL6C
200 P12BF7M-BL6C
200 P12BF8M-BL6C
100 P16BF9M-BL1C
100 P16BG0M-BL6C
200 P20BG2M-BL1C
100 P22BG3M-BL1C
100 P22BG4M-BL1C
200 P22BG5M-BL1C
100 P22BH9M-BL1R
200 P24BG7M-BL1C
200 P42BH0M-BL1C
200 P42BJ0M-BL1R
200 P06B03M
240
240
240
240
240
240
200
200
200
200
200
200 P24B14M
200 P06BF5M-BL6C
200 P18BG1M-BL1C
200 P36BG8M-BL1C
200 P42BH1M-BL1C
P06B37M
P06B38M
P24B12M
P30B13M
P42B11M
P42B44M
P06B04M
P24B02M
P36B02M
P48B03M
P54B03M
Output
Voltage
Panduit
Part Number
100 P08DE8M-BL6C
200 P12DE9M-BL6C
100 P16DF0M-BL6C
200 P16DF1M-BL6C
100 P16DF2M-BL1C
200 P24DF3M-BL1C
100 P24DF4M-BL1C
200 P24DF5M-BL1C
100 P24DG9M-BL1R
200 P38DF9M-BL1C
200 P38DH0M-BL1R
240
240
240
240
240
240
240
240
240
240
240
200
200
P06D19M
P24D34M
200 P06DE6M-BL6C
200 P24DF6M-BL1C
200 P36DF8M-BL1C
P06D38M
P06D39M
P24D43M
P30D05M
P42D04M
P42D42M
P06D02M
P24D04M
P36D02M
P48D03M
P42D07M
SmartZone ™ G5 Basic & Intelligent Power Distribution Units (iPDUs) for Japan
Monitored Per Outlet (MPO)
Region
JPN
Form Factor
0U FULL
Input Plug Type
NEMA L6-30P
Input
Voltage
Range
Input
Current per phase
Circuit
Breakers
Apparent
Power
(kVA)
Outlet
Count
200VAC 30 2 5.0 kVA 24
Outlet
Type
(20)C13, (4)C19
JPN 0U FULL NEMA L6-30P 200VAC 30 2 5.0 kVA 36 (30)C13, (6)C19
JPN
JPN
JPN
JPN
JPN
JPN
JPN
JPN
0U FULL
0U FULL
0U FULL
0U FULL
0U FULL
0U FULL
0U FULL
0U FULL
IEC 60309 3P+E 9h 60A (IP44)
NEMA L15-30P
NEMA L15-30P
NEMA L15-30P
200VAC
200VAC
200VAC
200VAC
NEMA L15-30P 200VAC
IEC 60309 3P+N+E 6h 16A (IP44) 415VAC
IEC 60309 3P+N+E 6h 32A (IP44) 415VAC
IEC 60309 3P+N+E 6h 16A (IP44) 415VAC
32
16
30
16
30
30
60
30
6
0
3
0
3
3
6
3
17.3 kVA
8.6 kVA
8.6 kVA
8.6 kVA
8.6 kVA
11.0 kVA
22.0 kVA
11.0 kVA
24
36
36
24
36
36
24
24
(12)C13, (12)C19
(18)C13, (6)C19
(30)C13, (6)C19
(30)C13, (6)C19
(30)C13, (6)C19
(18)C13, (6)C19
(12)C13, (12)C19
(30)C13, (6)C19
JPN 0U FULL - Wide IEC 60309 3P+N+E 6h 32A (IP44) 415VAC
JPN 0U FULL NEMA L22-30P 415VAC
JPN
JPN
0U FULL
0U FULL
NEMA L22-30P
NEMA L22-30P
415VAC
415VAC
32
30
30
30
6
6
6
6
22.0 kVA
17.3 kVA
17.3 kVA
17.3 kVA
36
24
24
24
(24)C13, (12)C19
(12)C13, (12)C19
(18)C13, (6)C19
(24)C13
JPN 0U FULL - Wide NEMA L22-30P 415VAC 30 6 17.3 kVA 36 (24)C13, (12)C19
JPN 0U FULL - Wide NEMA L22-30P 415VAC 30 6 17.3 kVA 36 (30)C13, (6)C19
JPN
JPN
0U FULL -
Wide+
0U FULL -
Wide +
NEMA L22-30P
NEMA L22-30P
415VAC
415VAC
30
30
6
6
17.3 kVA
17.3 kVA
48
48
(48)C13
(42)C13, (6)C19
Note: Minimum Order Quantity: 30 Pieces Per Part Number, Lead Time: 45 Business Days, Terms: Non-Cancellable / Non-Returnable
Monitored Switched (MS Series)
Region Form Factor Input Plug Type
Input
Voltage
Range
Input
Current per phase
Circuit
Breakers
Apparent
Power
(kVA)
Outlet
Count
Outlet
Type
Output
Voltage
Panduit
Part Number
Output
Voltage
Panduit
Part Number
200 P24FC0M-BL1C
200 P36FC3M-BL1C
240
240
240
240
240
240
240
240
200 P24F05M
200 P24FC1M-BL1C
200 P36FC5M-BL1C
200 P36FC9M-BL1B
200 P36FC9M-YL1B
240 P24F07M
240
240
P24F08M
P36F12M
P36F13M
P24F10M
P24F16M
P24F17M
P36F02M
P36F06M
P48F04M
P48F06M
JPN 0U FULL IEC 60309 3P+E 9h 60A (IP44) 200VAC 60 6 17.3 kVA 24 (12)C13, (12)C19 200 P24E32M
JPN
JPN
0U FULL
0U FULL
IEC 60309 3P+N+E 6h 16A (IP44) 415VAC
IEC 60309 3P+N+E 6h 32A (IP44) 415VAC
JPN 0U FULL IEC 60309 3P+N+E 6h 16A (IP44) 415VAC
JPN 0U FULL - Wide IEC 60309 3P+N+E 6h 32A (IP44) 415VAC
16
32
16
32
0
6
0
6
11.0 kVA
22.0 kVA
11.0 kVA
22.0 kVA
36
36
24
24
(18)C13, (6)C19
(12)C13, (12)C19
(30)C13, (6)C19
(24)C13, (12)C19
JPN
JPN
0U FULL
0U FULL
JPN 0U FULL
JPN 0U FULL - Wide
NEMA L22-30P
NEMA L22-30P
NEMA L22-30P
NEMA L22-30P
415VAC
415VAC
415VAC
415VAC
30
30
30
30
6
6
6
6
17.3 kVA
17.3 kVA
17.3 kVA
17.3 kVA
24
24
24
36
(12)C13, (12)C19
(18)C13, (6)C19
(24)C13
(24)C13, (12)C19
JPN 0U FULL - Wide NEMA L22-30P 415VAC 30 6 17.3 kVA 36 (30)C13, (6)C19
JPN
JPN
0U FULL -
Wide +
0U FULL -
Wide +
NEMA L22-30P
NEMA L22-30P
415VAC
415VAC
30
30
6
6
17.3 kVA
17.3 kVA
48
48
(48)C13
(42)C13, (6)C19
Note: Minimum Order Quantity: 30 Pieces Per Part Number, Lead Time: 45 Business Days, Terms: Non-Cancellable / Non-Returnable
240
240
240
240
240
240
240
240
240
240
240
P24E02M
P24E03M
P36E08M
P36E09M
P24E06M
P24E12M
P24E13M
P36E02M
P36E06M
P48E04M
P48E06M
SmartZone ™ G5 Basic & Intelligent Power Distribution Units (iPDUs) for Japan
Monitored & Switched Per Outlet (MSPO)
Region Form Factor Input Plug Type
Input
Voltage
Range
Input
Current per phase
Circuit
Breakers
Apparent
Power
(kVA)
Outlet
Count
Outlet
Type
Output
Voltage
Panduit
Part Number
JPN 0U FULL IEC 60309 3P+E 9h 60A (IP44) 200VAC 60 6 17.3 kVA 24 (12)C13, (12)C19 200 P24G05M
JPN
JPN
0U FULL
0U FULL
IEC 60309 3P+N+E 6h 16A (IP44) 415VAC
IEC 60309 3P+N+E 6h 32A (IP44) 415VAC
JPN 0U FULL IEC 60309 3P+N+E 6h 16A (IP44) 415VAC
JPN 0U FULL - Wide IEC 60309 3P+N+E 6h 32A (IP44) 415VAC
JPN
JPN
0U FULL
0U FULL
JPN 0U FULL
JPN 0U FULL - Wide
NEMA L22-30P
NEMA L22-30P
NEMA L22-30P
NEMA L22-30P
415VAC
415VAC
415VAC
415VAC
16
32
16
32
30
30
30
30
0
6
0
6
6
6
6
6
11.0 kVA
22.0 kVA
11.0 kVA
22.0 kVA
17.3 kVA
17.3 kVA
17.3 kVA
17.3 kVA
24
24
36
36
24
24
24
36
(18)C13, (6)C19
(12)C13, (12)C19
(30)C13, (6)C19
(24)C13, (12)C19
(12)C13, (12)C19
(18)C13, (6)C19
(24)C13
(24)C13, (12)C19
JPN 0U FULL - Wide
JPN
NEMA L22-30P
NEMA L22-30P
415VAC
415VAC
30
30
6
6
17.3 kVA
17.3 kVA
36
48
(30)C13, (6)C19
(48)C13
JPN NEMA L22-30P 415VAC 30 6 17.3 kVA 48 (42)C13, (6)C19
Note: Minimum Order Quantity: 30 Pieces Per Part Number, Lead Time: 45 Business Days, Terms: Non-Cancellable / Non-Returnable
240
240
240
240
240
240
240
240
240
240
240
P24G07M
P24G08M
P36G15M
P36G16M
P24G10M
P24G18M
P24G19M
P36G02M
P36G06M
P48G04M
P48G06M
PANDUIT US/CANADA
Phone: 800.777.3300
PANDUIT EUROPE LTD.
London, UK
Phone: 44.20.8601.7200
WORLDWIDE SUBSIDIARIES AND SALES OFFICES
PANDUIT SINGAPORE PTE. LTD.
Republic of Singapore
Phone: 65.6305.7575
PANDUIT JPN
Tokyo, JPN
Phone: 81.3.6863.6000
PANDUIT LATIN AMERICA
Guadalajara, Mexico
Phone: 52.33.3777.6000
PANDUIT AUSTRALIA PTY. LTD.
Victoria, Australia
Phone: 61.3.9794.9020
For a copy of Panduit product warranties, log on to www.panduit.com/warranty
For more information
Visit us at www.panduit.com
Contact Customer Service by email: [email protected] or by phone: 800.777.3300
©2021 Panduit Corp.
ALL RIGHTS RESERVED.
PUSP83--WW-ENG
2/2021