Sonic Radiant 80 Instructions For Use Manual
Iklan
Iklan
Radiant miniRITE T R
Instructions for Use
www.sonici.com
Model overview
This booklet is valid for the Sonic Radiant™ family in the following hearing aid models:
FW 1
Sonic Radiant 100 - RT100 MNR T R 05714464011377
Sonic Radiant 80 - RT80 MNR T R
Sonic Radiant 60 - RT60 MNR T R
05714464011384
05714464011391
The following speakers are available for the above model:
Speaker 60
Speaker 85
Speaker 100 (Power Instrument)
Power receiver mold speaker 100 (Power Instrument)
Power receiver mold speaker 105 (Power Instrument)
Introduction to this booklet
This booklet guides you on how to use and maintain your new hearing aid. Ensure you read this booklet carefully, including the Warnings section. This will help you get the most benefit from your hearing aid.
Your hearing care professional has adjusted the hearing aid to meet your needs. If you have additional questions, contact your hearing care professional.
A hearing care professional (hearing aid professional, audiologist, ENT
(ear, nose and throat) doctor, and hearing aid dispenser) is a person who is appropriately educated, and has proven competency in professionally assessing hearing, selecting, fitting and delivering hearing instruments and rehabilitation care to persons with hearing loss.
The education of the hearing care professional is in accordance with national or regional regulations.
For your convenience, this booklet contains a navigation bar to help you navigate through the different sections.
About Start-up Handling Options Tinnitus Warnings More info
Intended use
Intended use
Indications for use
The hearing aid is intended to amplify and transmit sound to the ear.
Bilateral or unilateral impaired hearing of sensorineural, conductive or mixed type ranging from a slight (16 dB
HL*) to profound (95 dB HL*) degree of hearing loss, with an individual frequency configuration.
Intended user Person with hearing loss using a hearing aid and their caregivers. Hearing care professional responsible for adjusting the hearing aid.
Intended user group Adults and children older than 36 months.
Use environment
Contraindications
Indoor and outdoor.
Not suitable for infants below 36 months. Users of active implants must pay special attention when using the hearing aid. For more information read the
Warnings section.
Clinical benefits The hearing aid is designed to provide better speech understanding to help ease communication with the aim of improving quality of life.
* As specified by the American Speech-Language-Hearing Association, asha.org, using pure-tone average of 0.5, 1 and 2 kHz.
IMPORTANT NOTICE
The hearing aid amplification is uniquely adjusted and optimized for your personal hearing capabilities during the hearing aid fitting performed by your hearing care professional.
In short
Charging
Ensure you charge the hearing aid every night. The LED light on the hearing aid turns ORANGE when the hearing aid is charging and GREEN when fully charged.
It takes three hours to fully charge the hearing aid.
ON/OFF
The hearing aid turns ON when you remove it from the charger.
The hearing aid turns OFF when you place it in the charger.
Ensure you always leave the charger connected to a power source when the hearing aid is seated in the charging port.
Turning OFF the charger makes the hearing aid turn ON and start using battery power.
Table of contents
About
Your hearing aid, speaker and earpiece
Hearing aid
Start-up
Charging time
Battery performance
Turn hearing aid ON / OFF using the charger
Turn hearing aid ON / OFF using the push button
Low battery indication
Identify left and right hearing aid
Put on hearing aid
12
14
20
21
22
16
17
18
19
Continues on next page
Table of contents
Handling
Cleaning
Replace standard earpieces
ProWax miniFit filter
Clean customized earpieces
Replace ProWax filter
Hearing aid storage
Flight mode
Options
Optional features and accessories
Change volume
Change program
Mute your hearing aid
Using your hearing aid with iPhone, iPad and iPod
Using your hearing aid with Android devices
Pairing and compatibility
Wireless accessories and other options
41
42
43
44
36
37
38
40
31
32
34
24
26
28
30
Tinnitus
Warnings
General warnings
More info
Tinnitus SoundSupport™ (optional)
Sound options and volume adjustments
Limitation on use time
Tinnitus SoundSupport warnings
54
Troubleshooting 64
Water & dust resistant (IP68) 68
Conditions of use
Technical information
69
70
Mobile phone
Warranty
Your individual hearing aid settings
Sound and LED light indicators
Technical Data
72
79
80
83
88
46
48
50
53
About
Your hearing aid, speaker and earpiece
Ear grip
(optional)
The hearing aid uses one of the following speakers:
Standard speakers
60 85 100 Power mold speakers
100
105
12 About Start-up Handling Options Tinnitus Warnings More info
The speakers use one of the following earpieces:
Standard earpieces Customized earpieces
OpenBass dome MicroMold
Bass dome, double vent
Power dome
LiteTip
Grip Tip
Available in small and large, left and right, with or without vent.
VarioTherm® MicroMold
VarioTherm® LiteTip
VarioTherm® is a registered trademark of Dreve.
Dome sizes
5 mm* 6 mm 8 mm 10 mm
*Only as OpenBass dome for speaker 60
12 mm
Note
For details on replacing the dome, see the Replace standard earpieces section.
13
Hearing aid
What it is and does
Microphones
Sound in
LED light
Charging, ON, OFF,
Flight mode status
Ear grip
Holds the speaker in place (optional)
Wax filter
Protects the speaker from earwax damage
Push button
Upper part:
Volume up, program change
Lower part:
ON, OFF, Flight mode, volume down, program change
Rechargeable battery
Can only be replaced by the hearing care professional
Speaker
Sound out
14 About Start-up Handling Options Tinnitus Warnings More info
Start-up
Charging time
Ensure you fully charge your hearing aid before first time use.
Charge your hearing aid every night. That ensures you start your day with a fully charged hearing aid. If your hearing aid’s battery is completely drained, the normal charging time is:
3 hours
Fully charged
1 hour
50% charged
0.5 hour
25% charged
When the battery is fully charged, the charging process stops automatically. Leave the hearing aid in the charger when you do not use it and remember to keep the charger connected to a power source at all times.
Be aware that charging time may vary depending on the remaining capacity of the battery and between the left / right hearing aid.
For instructions on how to use your charger, see the charger’s
Instructions for use.
16 About Start-up Handling Options Tinnitus Warnings More info
Battery performance
The daily battery performance varies depending on your individual use and hearing aid settings.
Streaming sound from e.g. TV, mobile phone or connectivity devices can influence daily battery performance.
If your hearing aid runs out of battery, ensure you recharge it by placing it in the charger. Be aware that restarting the hearing aid does not give you more usage time.
For the best charging conditions, ensure the room temperature is in the range of +10°C and +35°C (50°F and 95°F).
If your hearing aid does not perform for a full day, you may need to replace the battery. If so, contact your hearing care professional.
17
Turn hearing aid ON / OFF using the charger
Your hearing aid automatically turns ON when removed from the charger.
The hearing aid LED light turns GREEN after approximately six seconds, confirming that it is ready for use. Depending on your hearing aid settings, you may also hear a start-up jingle.
Your hearing aid automatically turns OFF when placed in the charger and starts charging. The hearing aid LED light turns ORANGE .
IMPORTANT NOTICE
Ensure you always leave the charger connected to a power source when the hearing aid is seated in the charging port. Turning the charger OFF makes the hearing aid turn ON and start using battery power.
18 About Start-up Handling Options Tinnitus Warnings More info
Turn hearing aid ON / OFF using the push button
The hearing aid can be turned ON / OFF using the push button.
To turn ON
Press and hold the lower part of the push button for approximately two seconds.
Release the button and wait until the hearing aid LED light turns GREEN .
The hearing aid is now turned ON. Depending on your hearing aids’ settings, you may hear a start-up jingle.
To turn OFF
Press and hold the lower part of the push button for approximately three seconds until the hearing aid
LED light turns ORANGE. The hearing aid plays four descending tones. Release the push button and the hearing aid is turned OFF.
For information regarding tones, see the Sound and LED light indicators section.
19
Low battery indication
When the battery is running low, you hear three alternate beeps. This gives you approximately two hours before the hearing aid runs out of battery.
The beeps are repeated every 30 minutes. Just before the battery runs out, you hear four descending tones.
Be aware that if you are streaming audio to your hearing aid (from e.g.
TV or mobile phone) and you hear three alternate beeps, you have approximately one hour before the hearing aid runs out of battery.
To extend battery performance, ensure you stop any streaming taking place.
Three alternate beeps
= The battery is running low.
Four descending tones
= The battery has run out.
LED light (optional)
Continuous ORANGE blinks indicate low battery.
20 About Start-up Handling Options Tinnitus Warnings More info
Identify left and right hearing aid
It is important to distinguish between the left and the right hearing aid, as they may be programed differently.
You can find left/right color indicators on the hearing aid itself and on
60 and 85 speakers as shown. Indicator markings (either L or R) can also be found on 100 speakers and some earpieces.
For 105 speakers, the indicator is found on the earpiece.
A RED indicator marks the
RIGHT hearing aid.
A BLUE indicator marks the LEFT hearing aid.
21
Put on hearing aid
Step 1 Step 2 Step 3
Place the hearing aid behind your ear.
You should always use the speaker with an earpiece attached.
Ensure you only use parts designed for your hearing aid.
Hold the bend of the speaker wire between your thumb and index finger.
The earpiece should point toward the opening of the ear canal.
Ear grip
(optional)
Gently push the earpiece into your ear canal until the speaker wire sits close to your head.
If the speaker has an ear grip, place it in the ear so it follows the contour of the ear.
22 About Start-up Handling Options Tinnitus Warnings More info
Handling
Cleaning
The MultiTool contains a brush and wire loop for cleaning and removing earwax. If you need a new MultiTool, contact your hearing care professional.
Magnet Wire loop
Brush
IMPORTANT NOTICE
The MultiTool has a built-in magnet. Keep the MultiTool at least
30 centimeters (1 foot) away from credit cards and other magneticallysensitive devices.
24 About Start-up Handling Options Tinnitus Warnings More info
Do not drop your hearing aid when handling it. Ensure you hold it over a soft surface to avoid damage while cleaning it.
Clean the microphone openings
Use the MultiTool brush to carefully brush debris away from the openings and the surface around the openings.
Microphone openings
Ensure that you do not forcefully squeeze parts of the MultiTool into the microphone openings. This may damage the hearing aid.
IMPORTANT NOTICE
To clean the hearing aid, use a soft, dry cloth. The hearing aid must never be washed or immersed in water or other liquids.
25
Replace standard earpieces
It is important that you do not clean the standard earpiece (dome and
Grip Tip). If the earpiece is filled with earwax, replace it with a new one.
Grip Tip needs to be replaced at least once a month.
Step 1 Step 2 Step 3
Hold on to the speaker and pull off the earpiece.
Insert the speaker exactly into the middle of the earpiece to get a secure fit.
Push firmly to ensure that the earpiece is securely fastened.
26 About Start-up Handling Options Tinnitus Warnings More info
IMPORTANT NOTICE
If the earpiece is not on the speaker when removed from the ear, the earpiece may still be in the ear canal. For further instructions, consult your hearing care professional.
27
ProWax miniFit filter
The speaker has a white wax filter attached to the end where the earpiece is attached. The wax filter keeps earwax and debris from damaging the speaker.
Ensure you replace the filter when clogged, or if the hearing aid does not sound normal. Alternatively, contact your hearing care professional. Ensure you remove the earpiece from the speaker before replacing the wax filter. To do this, see the Replace standard earpieces section.
ProWax filter
IMPORTANT NOTICE
Ensure you always use the same type of wax filter as originally supplied with the hearing aid. If you are in doubt about the use or replacement of wax filters, contact your hearing care professional.
28 About Start-up Handling Options Tinnitus Warnings More info
Replace ProWax miniFit filter
1. Tool 2. Remove
New filter
Remove the tool from the shell. The tool has two pins, one empty for removal and one with the new wax filter.
Empty pin
Insert the empty pin into the wax filter in the speaker and pull it out.
3. Insert
New filter
Old filter
Final
Insert the new wax filter using the other pin, remove the tool, and throw it out.
Note
If you use a mold or LiteTip, your hearing care professional must replace the wax filter in the speaker.
29
Clean customized earpieces
Ensure that you regularly clean the earpiece.
The earpiece has a white wax filter* that keeps earwax and debris from damaging the speaker.
Ensure you replace the filter when clogged, or if the hearing aid does not sound normal.
Alternatively, contact your hearing care professional.
Clean the vent by inserting the brush through the hole, twisting it slightly.
Vent
ProWax filter
Note
If you use a Power receiver mold or LiteTip, your hearing care professional must replace the wax filter in the speaker.
* VarioTherm MicroMold and LiteTip do not have a wax filter
30 About Start-up Handling Options Tinnitus Warnings More info
Replace ProWax filter
1. Tool 2. Remove
New filter
New filter
Remove the tool from the shell. The tool has two pins, one empty for removal and one with the new wax filter.
Insert the empty pin into the wax filter in the earpiece and pull it out.
3. Insert
Old filter
Insert the new wax filter using the other pin, remove the tool, and throw it out.
31
Hearing aid storage
When you are not using your hearing aid, the charger is the best place to keep it.
To ensure your hearing aid is always charged, place the hearing aid in the charger and make sure it is plugged in to power.
To ensure the longest life of the rechargeable battery in the hearing aid, do not expose it to excessive heat. For example, do not leave the hearing aid in the sun in front of a window or in a car, even if the hearing aid is in the charger.
32 About Start-up Handling Options Tinnitus Warnings More info
Long-term storage
Before you put away or store the hearing aid for a prolonged period of time (more than 14 days), ensure you first fully charge the hearing aid, and then turn it OFF. This way the battery can be charged again.
Note
To protect the rechargeable battery, it is necessary that you fully charge the hearing aid every six months. If a stored hearing aid is not charged within a six month period, the rechargeable battery must be replaced.
For instructions on how to charge your hearing aid, see the charger’s instructions for use.
33
Flight mode
To activate and deactivate Flight mode, press and hold the lower part of the push button for seven seconds.
When you activate or deactivate Flight mode, the hearing aid plays four descending tones and a short jingle. In addition, the following are the hearing aid LED light patterns that are displayed:
When activated: One long ORANGE blink followed by three sequences of one GREEN and two ORANGE blinks.
This confirms that flight mode is activated.
When deactivated: One long ORANGE blink, followed by two long GREEN blinks. This confirms that flight mode is deactivated.
For more information about sounds and lights, see the
Sound and LED light indicators section.
34 About Start-up Handling Options Tinnitus Warnings More info
Be aware that pressing the push button on one hearing aid, activates
Flight mode on both hearing aids.
Note
When Flight mode is activated, Bluetooth® is turned OFF, however be aware that the hearing aid is still turned ON and functioning.
35
Options
Optional features and accessories
The features and accessories described in the following pages are optional. For more information about features and accessories, contact your hearing care professional.
If you experience difficult listening situations, ensure you talk to your hearing care professional, as it may be helpful to add a special program to your hearing aids.
Write down hearing situations in which you may need help.
36 About Start-up Handling Options Tinnitus Warnings More info
Change volume
The push button lets you adjust the volume. When you increase or decrease the volume, you hear a beep.
For information regarding button press times, see the table General settings overview for your hearing aid , in the Your individual hearing aid settings section at the end of this booklet.
MAXIMUM
Press button to increase volume
Press button to decrease volume
START-UP
VOLUME
MINIMUM
37
Change program
Your hearing aid can save up to four different programs configured by your hearing care professional. Depending on the program you choose
(1,2,3 or 4), you hear one to four tones.
For information regarding tones, see the Sound and LED light indicators section.
For information regarding button press times see the table General settings overview for your hearing aid , in the Your individual hearing aid settings section at the end of this booklet.
38 About Start-up Handling Options Tinnitus Warnings More info
Press the push button to switch between programs.
The program cycle switches one program forward when the upper part of the push button is pressed, for example program 1 to 2 or program 4 to 1.
If the lower part of the push button is pressed, the program cycle goes backward, for example 2 to 1 or program 1 to 4.
39
Mute your hearing aid
You can mute your hearing aid by using one of the following optional devices / app:
• SoundLink 2 App
• SoundClip-A
• RC-A
How to unmute your hearing aid
You can unmute the hearing aid by using one of the optional devices / app or by applying a short press to the upper or lower part of the button on the hearing aid.
IMPORTANT NOTICE
Do not use the mute function as an OFF button, as the hearing aid is still using battery power in this mode.
40 About Start-up Handling Options Tinnitus Warnings More info
Using your hearing aid with iPhone, iPad and iPod
Sonic Radiant is a Made for iPhone® hearing aid and allows for direct communication and control with iPhone, iPad® or iPod touch®*.
For assistance in using your hearing aid with any of these products, contact your hearing care professional.
Use of the Made for Apple badge means that an accessory has been designed to connect specifically to the Apple products identified in the badge, and has been certified by the developer to meet Apple performance standards.
Apple is not responsible for the operation of this device or its compliance with safety and regulatory standards.
Please note that use of this Accessory with iPod, iPhone, or iPad may affect wireless performance.
41
Using your hearing aid with Android devices
Sonic Radiant supports Audio Streaming for Hearing Aids (ASHA) and can be used for direct communication and control with selected
Android™ devices*.
For assistance in using your hearing aid with Android devices, contact your hearing care professional.
42 About Start-up Handling Options Tinnitus Warnings More info
Pairing and compatibility
For instructions on how to pair your hearing aid with iPhone, iPad, iPod touch or Android devices, see the following website: www.sonici.com/connectivitysupport
* For a list of compatible iPhone, iPad, iPod touch and Android devices, see the following website: www.sonici.com/compatibilitycom/support
43
Wireless accessories and other options
There is a range of accessories available as an enhancement to your wireless hearing aid. These can enable you to hear and communicate better in many everyday situations.
SoundClip-A
A device that can be used as remote microphone and handsfree headset when paired to your mobile phone.
TV-A
A device that streams sound from a TV or electronic audio device, to your hearing aid.
Phone Adapter 2.0
A device that when used together with hearing aids and SoundClip-A, lets you communicate hands-free via a landline phone.
RC-A
A device that lets you change program, adjust volume, or mute your hearing aid.
44 About Start-up Handling Options Tinnitus Warnings More info
EduMic
A device that can be used as a remote microphone in classrooms, work environments, public places
(using Telecoil), and other settings.
SoundLink 2 App
An application that lets you control your hearing aid from your mobile phone or tablet. For iPhone, iPad, iPod touch, and
Android devices.
Telecoil
Telecoil can help you hear better when using a phone with a built-in loop or when in buildings with teleloop systems such as theaters, places of worship, or lecture rooms.
This symbol is shown wherever a teleloop has been installed.
Apple, the Apple logo, iPhone, iPad, and iPod touch are trademarks of Apple Inc., registered in the U.S. and other countries. App Store is a service mark of Apple Inc. Android, Google Play, and the Google Play logo are trademarks of Google LLC.
45
Tinnitus
Tinnitus SoundSupport™ (optional)
Intended use of Tinnitus SoundSupport
Tinnitus SoundSupport is a tool intended to generate sounds to provide temporary relief for patients suffering from tinnitus as part of a tinnitus management program.
The target population is the adult population over 18 years of age.
Tinnitus SoundSupport is targeted to licensed hearing care professionals (audiologists, hearing aid specialists, or otolaryngologists) who are familiar with the evaluation and treatment of tinnitus and hearing loss. Fitting of Tinnitus SoundSupport must be done by a hearing care professional participating in a tinnitus management program.
46 About Start-up Handling Options Tinnitus Warnings More info
Guidelines for tinnitus sound generator users
The following instructions contain information about Tinnitus
SoundSupport, which may have been enabled in your hearing aids by your hearing care professional.
Tinnitus SoundSupport is a tinnitus management device intended to generate sound of sufficient intensity and bandwidth to help manage tinnitus.
Your hearing care professional will also be able to offer the appropriate follow-up care. It is important to follow his/her advice and directions regarding such care.
Prescription use only
Good health practice requires that the person reporting tinnitus has a medical evaluation by a licensed ear physician before using a sound generator. The purpose of such an evaluation is to ensure that any medically-treatable condition that may cause tinnitus is identified and treated prior to using a sound generator.
47
Sound options and volume adjustments
Tinnitus SoundSupport is programed by your hearing care professional to match your hearing loss and preferences for tinnitus relief. It offers a number of different sound options. Together with your hearing care professional, you can select your preferred sound(s).
Tinnitus SoundSupport programs
Together with your hearing care professional, you decide for which programs you may want to have Tinnitus SoundSupport activated.
The sound generator can be activated in up to four different programs.
Mute
If you are in a program for which Tinnitus SoundSupport is activated, the mute functionality only mutes the environmental sounds, and not the sound from Tinnitus SoundSupport. For information on how to mute your hearing aids, see the Mute your hearing aids section.
48 About Start-up Handling Options Tinnitus Warnings More info
Volume adjustments with Tinnitus SoundSupport
When you select a hearing aid program for which Tinnitus SoundSupport is activated, your hearing care professional can only set the push button on your hearing aid to work as a volume control for the tinnitus relief sound.
Your hearing care professional sets the volume control for the sound generator in one of two ways:
A) Change volume in each ear separately, or
B) Change volume in both ears simultaneously.
For more information about volume adjustments with Tinnitus
SoundSupport, see the table Tinnitus SoundSupport settings overview for your hearing aid in the Your individual hearing aid settings section at the end of this booklet.
49
Limitation on use time
Daily use
The volume levels of Tinnitus SoundSupport can be set to a level which could lead to permanent hearing damage when used for a prolonged period of time. Your hearing care professional will advise you of the maximum amount of time per day you should use Tinnitus
SoundSupport. It should never be used at uncomfortable levels.
See the table Tinnitus SoundSupport: Limitation on use , in the Your individual hearing aid settings section at the end of this booklet to learn how many hours per day you can safely use the relief sound in your hearing aid.
50 About Start-up Handling Options Tinnitus Warnings More info
Important information for hearing care professionals about Tinnitus SoundSupport
Device description
Tinnitus SoundSupport is a module function that can be enabled in the hearing aids by the hearing care professional.
Maximum wearing time
The wearing time of Tinnitus SoundSupport will decrease as you increase the level above 80 dB(A) SPL. The fitting software automatically displays a warning when the hearing aid exceeds
80 dB(A) SPL. For more information, in the fitting software, next to the tinnitus fitting graph, see the Max wearing time indicator .
The volume control is deactivated
By default the volume control for the sound generator is deactivated in the hearing aid. Risk of noise exposure increases when the volume control is activated.
51
If the volume control is activated
A warning may be displayed if you activate the tinnitus volume control in the Buttons & Indicators screen. This occurs if the relief sound can be listened to at levels that may cause hearing damage.
The Max wearing time table in the fitting software displays the number of hours the patient can safely use Tinnitus SoundSupport.
1. Be aware and note down the maximum wearing time for each program for which Tinnitus SoundSupport is activated.
2. Ensure you write those values on the Tinnitus SoundSupport:
Limitation on use table in the back of this booklet.
3. Instruct your patient accordingly.
52 About Start-up Handling Options Tinnitus Warnings More info
Tinnitus SoundSupport warnings
If your hearing care professional has activated the sound generator Tinnitus
SoundSupport, ensure you pay attention to the following warnings.
There are some potential concerns associated with the use of any sound generated by a tinnitus management device. Among them are the potential worsening of tinnitus, and/or a possible change in hearing thresholds.
Should you experience or notice a change in hearing or tinnitus, or any dizziness, nausea, headaches, heart palpitations, or possible skin irritation at the point of contact with the device, you should immediately discontinue use of the device and consult a medical, audiology, or other hearing care professional.
As with any device, misuse of the sound generator feature may cause potentially harmful effects. Care should be taken to prevent unauthorized use and to keep the device out of reach of children and pets.
Maximum wearing time
Always follow the maximum wearing time per day of the Tinnitus SoundSupport advised by your hearing care professional.
Prolonged use may lead to worsening of your tinnitus or of your hearing loss.
53
Warnings
General warnings
For your personal safety and to ensure correct usage, you should familiarize yourself fully with the following general warnings before using your hearing aid.
Consult your hearing care professional if you experience unexpected operations or serious incidents with your hearing aid during use or because of its use. Your hearing care professional will support you with issue handling and, if relevant, reporting to the manufacturer and/or the national authorities.
Please note that a hearing aid will not restore normal hearing and will not prevent or improve a hearing impairment resulting from organic conditions. Hearing aid is only a part of hearing habilitation and may need to be supplemented by auditory training and instruction in lipreading. Furthermore, note that in most cases, infrequent use of a hearing aid does not permit a user to attain full benefit from it.
This hearing aid is supported by a nonremovable rechargeable lithium-ion battery cell. Please ensure to charge the hearing aid and familiarize yourself with the safety and handling information related to rechargeable hearing aids.
Do not try to get access to the battery inserted in the hearing instrument. The battery must only be replaced by your hearing care professional.
Only charge the hearing aid with a designated charger. Other chargers risk destroying the hearing aid and battery.
If a battery or hearing aid is swallowed, see a doctor immediately.
54 About Start-up Handling Options Tinnitus Warnings More info
Usage of hearing aids
Hearing aids should be used only as directed and adjusted by your hearing care professional. Misuse can result in sudden and permanent hearing loss.
Never allow others to wear your hearing aid, as incorrect usage could cause permanent damage to their hearing.
Choking hazards and risk of swallowing small parts
Hearing aids and their parts should be kept out of reach of children and anyone who might swallow these items or otherwise cause injury to themselves.
If a hearing aid or small part is swallowed, see a doctor immediately.
If a battery or hearing aid is swallowed, see a doctor immediately and contact the
National Poison Center at 1-800-222-1222 or National Battery Ingestion Hotline at
1-800-498-8666.
Explosives
The hearing aid is safe to use under normal usage conditions. The hearing aid has not been tested for compliance with international standards concerning explosive environments.
Therefore, do not use the hearing aid in environments with danger of explosions e.g. mines, oxygen rich environments or areas where flammable anaesthetics are handled.
Fatality hazards and risk of swallowing lithium-ion batteries or placing them in the ear or nose
Never swallow lithium-ion batteries nor place them in the ear or the nose as this may lead to serious injury or death in as little as two hours. This can be due to chemical burns, which can permanently damage the nose or ear or potentially lead to perforation of the inner organs. If a lithium-ion battery is swallowed or placed in the ear or nose, seek emergency medical treatment immediately.
Continues on next page
55
General warnings
Rechargeable battery
Do not attempt to open the hearing aid, as it may damage the battery.
Never attempt to replace the battery. If battery replacement is needed, please return your device to your hearing care professional. The service guarantee is void if there are signs of tampering.
In case of battery leakage do not wear your hearing aid, as it may cause skin irritation due to acids coming from the leaking battery. If your skin has been in contact with the leaked battery acids, use a wet cloth to wipe it off and ensure no acid is left on your skin. If you experience skin irritation, consult your doctor. For further handling instructions of your hearing instrument consult your hearing care professional.
The safety of recharging batteries using a USB connector is determined by the external signal source. When connected to external equipment plugged into a power socket, this equipment must comply with IEC 62368-1 or equivalent safety standards.
Dysfunction
Be aware of the possibility that your hearing aid may stop working without notice. Keep this in mind when you depend on warning sounds (e.g. when you are in traffic). The hearing aids may stop functioning, for instance if the batteries have expired or if the tubing is blocked by moisture or earwax.
56 About Start-up Handling Options Tinnitus Warnings More info
Active implants
The hearing aid has been thoroughly tested and characterized for human health according to international standards for human exposure (Specific Absorption Ratio
- SAR), induced electromagnetic power and voltages into the human body.
The exposure values are well below internationally accepted safety limits for
SAR, induced electromagnetic power and voltages into the human body defined in the standards for human health and coexistence with active medical implants such as pacemakers and heart defibrillators.
If you have an active brain implant, please contact the manufacturer of your implantable device for information about the risk of interference.
The AutoPhone or MultiTool (which has a built-in magnet) should be kept more than
30 centimeters (1 foot) away from the implant, e.g. do not carry it in your breast pocket.
Follow the guidelines recommended by the manufacturers of implantable defibrillators and pacemakers regarding their use with magnets.
Detached earpiece in ear canal
If the earpiece is not on the speaker when removed from the ear, the earpiece may still be in the ear canal. For further instructions, consult your hearing care professional.
X-ray/CT/MR/PET scanning, electrotherapy and surgery
Remove your hearing aid before X-ray, CT/
MR/PET scanning, electrotherapy, surgery, etc. as your hearing aid may be damaged when exposed to electromagnetic fields.
Continues on next page
57
General warnings
Heat and chemicals
The hearing aid must never be exposed to extreme heat, e.g. left inside a parked car in the sun.
The hearing aid must not be dried in microwave ovens or other ovens.
The chemicals in cosmetics, hairspray, perfume, aftershave lotion, sunscreen lotion, and insect repellent can damage the hearing aid. Always remove your hearing aid before applying such products and allow time to dry before use.
Power instrument
Special care should be exercised in selecting, fitting and using a hearing aid where the maximum sound pressure capability exceeds 132 dB SPL
(IEC 60138-4/IEC 711), as there may be risk of impairing the remaining hearing of the hearing aid user.
For information on whether your hearing aid is a power instrument, see the model overview.
Possible side effects
Hearing aids and earpieces may cause an accelerated accumulation of earwax.
The non-allergenic materials used in hearing aids may in rare cases cause a skin irritation or other side effects.
Please seek consultation with a physician if these conditions occur.
58 About Start-up Handling Options Tinnitus Warnings More info
Use on aircraft
Your hearing aid uses Bluetooth. On board an aircraft, the hearing aid must be put into flight mode to deactivate Bluetooth, unless Bluetooth is permitted by the flight personnel.
Use of third-party accessories
Only use accessories, transducers or cables supplied by the manufacturer. Nonoriginal accessories may result in reduced electromagnetic compatibility (EMC) of your device.
Modification of hearing aids is not allowed
Changes or modifications not expressly approved by the manufacturer will void the warranty of the equipment.
Interference
The hearing aid has been thoroughly tested for interference according to the most stringent international standards.
Electromagnetic interference may occur in the vicinity of equipment with the symbol to the left. Portable and mobile RF (radio frequency) communications equipment can affect the performance of your hearing aid. If your hearing aid is affected by electromagnetic interference, move away from the source to reduce the interference.
Distracted user
Using your hearing aid can distract you.
Be aware of your surroundings while using your hearing aid. Please refer to national traffic laws regarding the use of communication devices while in traffic.
Continues on next page
59
General warnings
Warning to hearing care professional
A hearing care professional should advise a prospective hearing aid user to consult immediately with a licensed physician
(preferably an ear specialist) before dispensing a hearing aid if the hearing care professional determines through inquiry, actual observation, or review of any other available information concerning the prospective user, that the prospective user has any of the following conditions:
(i)
(ii)
Visible congenital or traumatic deformity of the ear.
History of active drainage from the ear within the previous
90 days.
(iii)
(iv)
(v)
(vi)
(vii)
(viii)
History of sudden or rapidly progressive hearing loss within the previous 90 days.
Acute or chronic dizziness.
Unilateral hearing loss of sudden or recent onset within the previous 90 days.
Audiometric air-bone gap equal to or greater than 15 decibels at
500 Hertz (Hz), 1,000 Hz, and
2,000 Hz.
Visible evidence of significant cerumen accumulation or a foreign body in the ear canal.
Pain or discomfort in the ear.
60 About Start-up Handling Options Tinnitus Warnings More info
Special care should be exercised in selecting and fitting a hearing aid whose maximum sound pressure capability exceeds 132 dB
SPL as there may be risk of impairing the remaining hearing of the hearing aid user.
Important notice for prospective hearing aid users
Good health practice requires that a person with a hearing loss have a medical evaluation by a licensed physician
(preferably a physician who specializes in diseases of the ear) before purchasing a hearing aid. Licensed physicians who specialize in diseases of the ear are often referred to as Otolaryngologists, Otologists or Otorhinolaryngologists. The purpose of medical evaluation is to ensure that all medically treatable conditions that may affect hearing are identified and treated before the hearing aid is purchased.
Following the medical evaluation, the physician will give you a written statement that states that your hearing loss has been medically evaluated and that you may be considered a candidate for a hearing aid. The physician will refer you to an audiologist or a hearing aid dispenser, as appropriate, for a hearing aid evaluation.
Continues on next page
61
General warnings
The audiologist or hearing care professional will conduct a hearing aid evaluation to assess your ability to hear with and without a hearing aid. The hearing aid evaluation will enable the audiologist or dispenser to select and fit a hearing aid to your individual needs. If you have reservations about your ability to adapt to amplification, you should inquire about the availability of a trial, rental or purchase-option program.
Many hearing care professionals now offer programs that permit you to wear a hearing aid for a period of time for a nominal fee, after which you may decide if you want to purchase the hearing aid. Federal law limits the sale of hearing aids to those individuals who have obtained a medical evaluation from a licensed physician.
Federal law permits a fully informed adult to sign a waiver statement declining the medical evaluation for religious or personal beliefs that preclude consultation with a physician. The exercise of such a waiver is not in your best health interest and its use is strongly discouraged. A hearing aid will not restore normal hearing and will not prevent or improve a hearing impairment resulting from organic conditions. A hearing aid is only part of hearing rehabilitation and may need to be supplemented by auditory training and lip reading.
62 About Start-up Handling Options Tinnitus Warnings More info
Children with hearing loss
In addition to seeing a physician for medical evaluation, a child with a hearing loss should be directed to an audiologist for evaluation and rehabilitation, since hearing loss may cause problems in language development and educational and social growth of a child. An audiologist is qualified by training and experience to assist in the evaluation and rehabilitation of a child with a hearing loss. If the user is an infant, small child, or person of mental incapacity, it is recommended that the hearing aid be modified with a tamper-resistant battery compartment.
63
More info
Troubleshooting
To troubleshoot the charger, see your charger’s Instructions for use.
Symptom Possible causes
Hearing aid is out of power
Dead battery
No sound
Clogged earpieces (dome, Grip Tip, or mold)
Intermittent or reduced sound
Squealing noise
Beeping
Clogged sound outlet
Moisture
Hearing aid is out of power
Hearing aid earpiece incorrectly inserted
Earwax accumulated in ear canal
If your hearing aid plays eight beeps, four times consecutively, your hearing aid needs a microphone service check
Note
If none of the above solutions work, consult your hearing care professional.
64 About Start-up Handling Options Tinnitus Warnings More info
Solutions
Charge the hearing aid
Contact your hearing care professional
Clean mold
Replace wax filter, dome, or Grip Tip
Clean mold or replace wax filter, dome, or Grip Tip
Gently wipe the hearing aid and let it dry
Charge the hearing aid
Re-insert the earpiece
Have ear canal examined by your doctor
Contact your hearing care professional
Symptom
No sound
Intermittent or reduced sound
Squealing noise
Beeping
Possible causes
Hearing aid is out of power
Dead battery
Clogged earpieces (dome, Grip Tip, or mold)
Clogged sound outlet
Moisture
Hearing aid is out of power
Hearing aid earpiece incorrectly inserted
Earwax accumulated in ear canal
If your hearing aid plays eight beeps, four times consecutively, your hearing aid needs a microphone service check
Solutions
Charge the hearing aid
Contact your hearing care professional
Clean mold
Replace wax filter, dome, or Grip Tip
Clean mold or replace wax filter, dome, or Grip Tip
Gently wipe the hearing aid and let it dry
Charge the hearing aid
Re-insert the earpiece
Have ear canal examined by your doctor
Contact your hearing care professional
Continues on next page
65
Troubleshooting
To troubleshoot the charger, see your charger’s Instructions for use.
Symptom Possible causes
The charger is not turned ON
The hearing aid or charger’s temperature is either too warm or too cold The hearing aid LED light remains turned OFF when the hearing aid is placed in the charger
Charging is incomplete. The room temperature exceeds
+35°C (+95°F), which prolongs the charging time. The charger has stopped charging to protect the battery.
The hearing aid is incorrectly seated in the charger
The hearing aid LED light blinks GREEN when it’s placed in the charger
The hearing aid LED light blinks ORANGE when the hearing aid is placed in the charger
Hearing aid has not been in use for a prolonged period of time
System error
Bluetooth connection failed
Pairing issue with
Apple device
Only one hearing aid is paired
66 About Start-up Handling Options Tinnitus Warnings More info
Solutions
Verify that the charger’s power plug is correctly connected
Move the charger and hearing aid to a location with a temperature between +5°C and +40°C
(+41°F and +104°F)
Reinsert the hearing aid into the charger. This completes the charging within approximately
15 minutes.
Check the charging ports for foreign objects
Depending on how depleted the battery in the hearing aid is, the hearing aid automatically resumes normal charging mode after a timeframe of up to 10 minutes. Ensure you leave the hearing aids in the charger during this process.
Contact your hearing care professional
1) Unpair your hearing aid
2) Turn Bluetooth OFF and ON again
3) Turn OFF and turn back ON the hearing aid
4) Re-pair hearing aid (For guidance, visit: www.sonici.com/connectivitycom/support)
Symptom
The hearing aid LED light remains turned OFF when the hearing aid is placed in the charger
Possible causes
The charger is not turned ON
The hearing aid or charger’s temperature is either too warm or too cold
Charging is incomplete. The room temperature exceeds
+35°C (+95°F), which prolongs the charging time. The charger has stopped charging to protect the battery.
The hearing aid is incorrectly seated in the charger
The hearing aid LED light blinks GREEN when it’s placed in the charger
The hearing aid LED light blinks ORANGE when the hearing aid is placed in the charger
Hearing aid has not been in use for a prolonged period of time
System error
Bluetooth connection failed
Pairing issue with
Apple device
Only one hearing aid is paired
Solutions
Verify that the charger’s power plug is correctly connected
Move the charger and hearing aid to a location with a temperature between +5°C and +40°C
(+41°F and +104°F)
Reinsert the hearing aid into the charger. This completes the charging within approximately
15 minutes.
Check the charging ports for foreign objects
Depending on how depleted the battery in the hearing aid is, the hearing aid automatically resumes normal charging mode after a timeframe of up to 10 minutes. Ensure you leave the hearing aids in the charger during this process.
Contact your hearing care professional
1) Unpair your hearing aid
2) Turn Bluetooth OFF and ON again
3) Turn OFF and turn back ON the hearing aid
4) Re-pair hearing aid (For guidance, visit: www.sonici.com/connectivitycom/support)
Note
If none of the above solutions work, consult your hearing care professional.
67
Water & dust resistant (IP68)
Your hearing aid is dust tight and protected against ingress of water, which means it is designed to be worn in all daily life situations.
Should your hearing aid come into contact with water and stop working, gently wipe off any water and let the hearing aid dry.
The water and dust resistance means you do not have to worry about your hearing aid getting wet when it rains, or if it comes into contact with sweat.
Before charging the hearing aid make sure to wipe off any moisture.
IMPORTANT NOTICE
Do not wear your hearing aid while showering or participating in water activities. Do not immerse your hearing aid in water or other liquids.
68 About Start-up Handling Options Tinnitus Warnings More info
Conditions of use
Operating conditions
Charging conditions
Transportation and storage conditions
Temperature: +5°C to +40°C (41°F to 104°F)
Humidity: 5% to 93% relative humidity, non-condensing
Atmospheric pressure: 700 hPa to 1060 hPa
Temperature: +5°C to +40°C (41°F to 104°F)
Humidity: 5% to 93% relative humidity, non-condensing
Atmospheric pressure: 700 hPa to 1060 hPa
Temperature and humidity shall not exceed the below limits for extended periods during transportation and storage:
Transportation:
Temperature: -20°C to +60°C (-4°F to 140°F)
Humidity: 5% to 93% relative humidity, non-condensing
Atmospheric pressure: 700 hPa to 1060 hPa
Storage:
Temperature: -20°C to +30°C (-4°F to 86°F)
Humidity: 5% to 93% relative humidity, non-condensing
Atmospheric pressure: 700 hPa to 1060 hPa
Note
For more information about the charger’s Conditions of use, see your charger’s Instructions for Use.
69
Technical information
The hearing aid contains the following two radio technologies:
The hearing aid contains a radio transceiver using short range magnetic induction technology operating at 3.84 MHz. The magnetic field strength of the transmitter is very weak and always below 15 nW (typically below –40 dBμA/m (–12.20 dBμA/ft) at
10 meters (33 feet) distance).
The hearing aid also contains a radio transceiver using Bluetooth Low Energy
(BLE) and a proprietary short-range radio technology, both operating at ISM band
2.4 GHz. The radio transmitter is weak and always below 9 mW equal to 9.6 dBm in total radiated power.
The hearing aid complies with international standards concerning electromagnetic compatibility and human exposure. Only use your hearing aid in areas where wireless transmission is permitted.
Due to the limited space available on the hearing aid, relevant approval markings can be found in this booklet. Additional information can be found in the Specification Guide on www.sonici.comcom
USA and Canada
This device contains a radio module
(DA AU5 MNR R) with the following certification ID numbers:
FCC ID: 2ACAHAU5MRTRC
IC: 11936A-AU5MRTRC
70 About Start-up Handling Options Tinnitus Warnings More info
Radiofrequency radiation exposure information
For body-worn operation, this device meets
FCC and Innovation, Science and Economic
Development Canada’s RF exposure limits and has been tested while in contact with the human body. The device must not be co-located or used in conjunction with any other antenna or transmitter.
Note:
The device complies with Part 15 of the
FCC rules and with Innovation, Science and
Economic Development Canada’s licenseexempt RSSs standards. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation.
71
Mobile phone
Some hearing aid users have reported a buzzing sound in their hearing aid when they are using mobile phones, indicating that the mobile phone and hearing aid may not be compatible.
The ANSI C63.19 standard determines the prediction of compatibility between a specific hearing aid and a mobile phone by: adding the numerical value of the rating for the hearing aid immunity to the numerical value of the rating for the mobile phone emissions. A sum of 4 would indicate that the combination of wireless device and hearing aid is usable; a combined rating that equals at least 5 would provide normal use; a combined rating of 6 or greater would indicate excellent performance.
Whereas all hearing aids have acoustic coupling, only the larger hearing aids have the physical space for telecoil (inductive) coupling.
These two types of coupling have different rating scales (M1-M4 for acoustic coupling and T1-T4 for telecoil coupling, respectively) and both ratings are therefore relevant when predicting the compatibility of a particular hearing aid.
For a hearing aid with both acoustic coupling and telecoil coupling with a rating of M4/
T2 and with a telephone rating of M3/T3), the combined rating is 7 (M4 + M3) for the acoustic coupling and 5 (T2 + T3) for the telecoil coupling. According to the guidelines given above, both types of coupling will thereby be acceptable, with the acoustic coupling indicating excellent performance and the telecoil coupling indicating normal use.
72 About Start-up Handling Options Tinnitus Warnings More info
The above equipment performance measurements, categories and system classifications are based upon the best information available, but it cannot be guaranteed that all users will be satisfied.
The immunity of miniRITE is at least M2. The immunity of miniRITE T is at least M2/T2.
The equipment performance measurements, categories and system classifications are based upon the best information available but cannot guarantee that all users will be satisfied.
IMPORTANT NOTICE
The performance of individual hearing aids may vary with individual mobile phones. Therefore, please try this hearing aid with your mobile phone or, if you are purchasing a new phone, be sure to try it with your hearing aid prior to purchase. For additional guidance, please ask your mobile phone provider for the booklet entitled “Hearing Aid Compatibility with Digital Wireless Cell
Phones.”
73
The manufacturer declares that this hearing aid is in compliance with the essential requirements and other relevant provisions of
Directive 2014/53/EU.
This medical device complies with
Medical Device Regulation (EU) 2017/745.
Declaration of Conformity is available from the headquarters.
Sonic Innovations, Inc.
2501 Cottontail Lane
Somerset, NJ 08873
USA www.sonici.com/doc
SBO Hearing A/S
Denmark
Waste from electronic equipment must be handled according to local regulations.
74 About Start-up Handling Options Tinnitus Warnings More info
Description of symbols and abbreviations used in this booklet
Warnings
Text marked with a warning symbol must be read before using the device.
Manufacturer
The device is produced by the manufacturer whose name and address are stated next to the symbol. Indicates the medical device manufacturer, as defined in EU Regulations
2017/745 and 2017/746.
CE mark
The device complies with all required EU regulations and directives.
The four digit number indicates the identification of the notified body.
Electronic waste (WEEE)
Recycle hearing aids, accessories or batteries according to local regulations.
Hearing aid users can also return electronic waste to their hearing care professional for disposal. Electronic equipment covered by Directive 2012/19/EU on waste and electrical equipment (WEEE).
Regulatory Compliance Mark (RCM)
The device complies with electrical safety, EMC and radio spectrum requirements for devices supplied to the Australian or New Zealand markets.
IP code
Indicates the class of protections against harmful ingress of water and particulate matter according to EN 60529. IP6X indicates total dust protection. IPX8 indicates the protection against the effects of continuous immersion in water.
Bluetooth logo
Registered trademark of Bluetooth SIG, Inc. where any use of such requires a license.
75
GTIN
Description of symbols and abbreviations used in this booklet
Made for Apple badges
Indicates that the device is compatible with iPhone, iPad and iPod touch.
Hearing loop
This logo incorporates the universal symbol for hearing assistance.
The “T” signifies that a hearing loop is installed.
Radio Frequency (RF) transmitter
Your hearing aid contains an RF transmitter.
Global Trade Item Number
A globally unique 14-digit number used to identify medical device products including medical device software. GTIN in this booklet is related to medical device firmware (FW).
GTIN on regulatory packaging label is related to medical device hardware.
76 About Start-up Handling Options Tinnitus Warnings More info
Description of additional symbols used on labels
Keep dry
Indicates a medical device that needs to be protected from moisture.
Caution symbol
Consult Instructions for use for warnings and cautions.
Catalog number
Indicates the manufacturer’s catalog number so that the medical device can be identified.
Serial number
Indicates the manufacturer’s serial number so that a specific medical device can be identified.
Medical Device
The device is a medical device.
Battery recycling symbol
Li-Ion battery recycling symbol
Temperature limit
Indicates the temperature limits to which the medical device can be safely exposed.
Humidity limitation
Indicates the range of humidity to which the medical device can be safely exposed.
Radio Frequency Identification
Indicates the presence of a passive radio-frequency identification tag incorporated into the device for manufacturing and service purposes.
77
International warranty
Your hearing aid is covered by an international limited warranty issued by the manufacturer for a period of 12 months from the date of delivery to you. This limited warranty covers manufacturing and material defects in the hearing aid itself, but not in accessories such as e.g. batteries, tubing, speakers, ear pieces and filters, etc. Problems arising from improper /incorrect handling or care, excessive use, accidents, repairs made by an unauthorized party, exposure to corrosive conditions, physical changes in your ear, damage due to foreign objects entering the device, or incorrect adjustments are NOT covered by the limited warranty and may void it. Under this warranty, the manufacturer will choose, in its sole discretion, whether to repair the hearing aid, or replace it with an equivalent model. The above warranty does not affect any legal rights that you might have under applicable national legislation governing the sale of consumer goods. Your hearing care professional may have issued a warranty that goes beyond the clauses of this limited warranty. Please consult him/her for further information.
If you need service
Take your hearing aid to your hearing care professional, who may be able to sort out minor problems and adjustments immediately.
Your hearing care professional can assist you to obtain warranty service from the manufacturer. Your hearing care professional may charge a fee for their services.
78 About Start-up Handling Options Tinnitus Warnings More info
Warranty
Certificate
Name of owner: _______________________________________________________
Hearing care professional: _______________________________________________
Hearing care professional’s address: _______________________________________
Hearing care professional’s phone: ________________________________________
Purchase date: ________________________________________________________
Warranty period: _______________ Month: ________________________________
Model left: ____________________ Serial no.: ______________________________
Model right: ___________________ Serial no.: ______________________________
79
Your individual hearing aid settings
To be filled out by your hearing care professional.
Tinnitus SoundSupport: Limitation on use n No limitation on use
Program Start-up volume (Tinnitus)
Max _______ hours per day n 1 n 2 n 3 n 4
Max _______ hours per day
Max _______ hours per day
Max _______ hours per day
Max volume (Tinnitus)
Max _______ hours per day
Max _______ hours per day
Max _______ hours per day
Max _______ hours per day
80 About Start-up Handling Options Tinnitus Warnings More info
n Yes
Tinnitus SoundSupport settings overview for your hearing aid
Left Right n No Tinnitus SoundSupport n Yes n No n A) How to change Tinnitus SoundSupport volume in each ear separately
To increase or decrease the volume (on one hearing aid only), use a short press on the upper or lower part of the push button repeatedly until you reach your desired level.
n B) How to change Tinnitus SoundSupport volume in both ears simultaneously
You can use one hearing aid to increase/decrease the sound in both hearing aids. When changing the volume in one hearing aid, the volume on the other hearing aid follows.
To increase volume, use a short press on the upper part of the push button repeatedly.
To decrease volume, use a short press on the lower part of the push button repeatedly.
To be filled out by your hearing care professional.
81
Left n Yes n No n Yes n No n Short press n Long press
General settings overview for your hearing aid
Change volume
Change program
Right n Yes n No n Yes n No n Short press n Long press
Volume control indicators
Beeps at min/max volume n ON n OFF n ON n OFF n ON n OFF
Beeps when changing volume
Beeps at start-up volume n ON n OFF n ON n OFF n ON n OFF n ON n OFF
Battery indicators
Low battery warning n ON n OFF
To be filled out by your hearing care professional.
82 About Start-up Handling Options Tinnitus Warnings More info
Sound and LED light indicators
Different sounds and light patterns indicate the hearing aid status. The different indicators are listed on the following pages. For light indicators on your charger, see the charger’s Instructions for use.
Your hearing care professional can set sound and LED light indicators to match your preferences.
Program
1
2
3
4 n
Sound n
LED light*
When to use
1 tone
2 tones
3 tones
4 tones
Short GREEN blink
*LED light blinks continuously or is repeated three times with short pauses
Continues on next page
83
ON/OFF
ON
OFF
Volume
Start-up volume
Minimum/maximum volume
Volume up/down
Mute activated on
SoundLink 2 App,
SoundClip-A or RC-A
Sound n Jingle n 4 descending tones
Sound n
2 beeps n n
3 beeps
1 beep
Long GREEN blink Short GREEN blink
LED light n n
LED light n n n n
LED light comments
Shown once
Continuous or repeated three times
Long ORANGE blink Short ORANGE blink
84 About Start-up Handling Options Tinnitus Warnings More info
Accessories
TV-A
SoundClip-A
Flight mode
Flight mode activated
Flight mode deactivated n
Sound
2 different tones
2 different tones n
Sound
4 descending tones
+ short jingle
4 descending tones
+ short jingle n
LED light n
LED light
*
Long GREEN blink Short GREEN blink
LED light comments
Continuous or repeated three times
Long ORANGE blink Short ORANGE blink
*Only available when three-time repetition is selected
Continues on next page
85
Warnings Sound LED light
Low battery
Battery shut down
Microphone service check needed
The hearing aid LED light does not turn ON when placed in the charger n
3 alternate beeps
4 descending tones
8 beeps repeated 4 times n n
Turned OFF
LED light comments
Continuously blinking
Repeated four times
See the
Troubleshooting section
86 About Start-up Handling Options Tinnitus Warnings More info
Warnings
The hearing aid LED light blinks ORANGE when the hearing aid is placed in the charger
The hearing aid LED light blinks GREEN when the hearing aid is placed in the charger
Sound
Long GREEN blink Short GREEN blink
LED light
Long ORANGE blink
LED light comments
Continuously blinking. See the
Troubleshooting section
Continuously blinking. See the
Troubleshooting section
Short ORANGE blink
87
Technical Data
Measured according to
American
National Standard
ANSI S3.22-2014,
IEC 60118-0:2015 and IEC 60318-
5:2006
Supply voltage:
Lithium ion
0 dB SPL ref. 20 mPa
Peak OSPL90
HF Average OSPL90
Peak Full-on Gain
HF Average Full-on Gain
Reference Test Gain
Frequency Range
Total Harmonic Distortion 500 Hz
Total Harmonic Distortion 800 Hz
Total Harmonic Distortion 1600 Hz
Equivalent Input Noise Level (omni/dir)
HF Average SPLITS (left/right ear)
Attack Time
Release Time
miniRITE T R
Sonic Radiant
100
106 dB SPL
103 dB SPL
36 dB
30dB
26 dB
100-9400 Hz
Sonic Radiant
80 & 60
106 dB SPL
103 dB SPL
36 dB
30 dB
26 dB
100-7500 Hz
<2 %
<2%
<2 %
17/28 dB SPL
<2 %
<2%
<2 %
17/29 dB SPL
83/83 dB SPL 83/83 dB SPL
5 ms 5 ms
18 ms 21 ms
88 About Start-up Handling Options Tinnitus Warnings More info
OSPL90 – Output
Sound
Pressure Level
Input: 90 dB SPL.
Technical setting: A0
Full-on Gain
Input: 50 dB SPL.
Technical setting: A0
Sonic Radiant 100 Sonic Radiant 80 & 60
89
Technical Data
Measured according to
American
National Standard
ANSI S3.22-2014,
IEC 60118-0:2015 and IEC 60318-
5:2006
Supply voltage:
Lithium ion
0 dB SPL ref. 20 mPa
Peak OSPL90
HF Average OSPL90
Peak Full-on Gain
HF Average Full-on Gain
Reference Test Gain
Frequency Range
Total Harmonic Distortion 500 Hz
Total Harmonic Distortion 800 Hz
Total Harmonic Distortion 1600 Hz
Equivalent Input Noise Level (omni/dir)
HF Average SPLITS (left/right ear)
Attack Time
Release Time
miniRITE T R
Sonic Radiant
100
117 dB SPL
114 dB SPL
55 dB
48 dB
37 dB
100-8900 Hz
Sonic Radiant
80 & 60
117 dB SPL
114 dB SPL
55 dB
48 dB
37 dB
100-7500 Hz
<2 %
<2%
<2 %
18/28 dB SPL
<2 %
<2%
<2 %
18/27 dB SPL
94/94 dB SPL 94/94 dB SPL
5 ms 5 ms
18 ms 18 ms
90 About Start-up Handling Options Tinnitus Warnings More info
OSPL90 – Output
Sound
Pressure Level
Input: 90 dB SPL.
Technical setting: A0
Full-on Gain
Input: 50 dB SPL.
Technical setting: A0
Sonic Radiant 100 Sonic Radiant 80 & 60
91
Technical Data
Measured according to
American
National Standard
ANSI S3.22-2014,
IEC 60118-0:2015 and IEC 60318-
5:2006
0 dB SPL ref. 20 mPa
Peak OSPL90
HF Average OSPL90
Peak Full-on Gain
HF Average Full-on Gain
Reference Test Gain
Frequency Range
Supply voltage:
Lithium ion Total Harmonic Distortion 500 Hz
Total Harmonic Distortion 800 Hz
Total Harmonic Distortion 1600 Hz
Equivalent Input Noise Level (omni/dir)
HF Average SPLITS (left/right ear)
Attack Time
Release Time
miniRITE T R
Sonic Radiant
100
124 dB SPL
120 dB SPL
57 dB
53 dB
42 dB
100-7500 Hz
Sonic Radiant
80 & 60
124 dB SPL
120 dB SPL
57dB
53 dB
42 dB
100-7500 Hz
<2 %
<2%
<2 %
16/28 dB SPL
<2 %
<2%
<2 %
17/29 dB SPL
100/100 dB SPL 100/100 dB SPL
4 ms 3 ms
7 ms 8 ms
92 About Start-up Handling Options Tinnitus Warnings More info
OSPL90 – Output
Sound
Pressure Level
Input: 90 dB SPL.
Technical setting: A0
Full-on Gain
Input: 50 dB SPL.
Technical setting: A0
Sonic Radiant 100 Sonic Radiant 80 & 60
93
Technical Data
Measured according to
American
National Standard
ANSI S3.22-2014,
IEC 60118-0:2015 and IEC 60318-
5:2006
Supply voltage:
Lithium ion
0 dB SPL ref. 20 mPa
Peak OSPL90
HF Average OSPL90
Peak Full-on Gain
HF Average Full-on Gain
Reference Test Gain
Frequency Range
Total Harmonic Distortion 500 Hz
Total Harmonic Distortion 800 Hz
Total Harmonic Distortion 1600 Hz
Equivalent Input Noise Level (omni/dir)
HF Average SPLITS (left/right ear)
Attack Time
Release Time
miniRITE T R
Sonic Radiant
100
127 dB SPL
123 dB SPL
64 dB
58 dB
47 dB
100-7900 Hz
Sonic Radiant
80 & 60
127 dB SPL
123 dB SPL
64dB
58 dB
47dB
100-7500 Hz
<2 %
<2%
<2 %
16/28 dB SPL
<2 %
<2%
<2 %
16/28 dB SPL
105/105 dB SPL 104/104 dB SPL
4 ms 4 ms
14 ms 15 ms
94 About Start-up Handling Options Tinnitus Warnings More info
OSPL90 – Output
Sound
Pressure Level
Input: 90 dB SPL.
Technical setting: A0
Full-on Gain
Input: 50 dB SPL.
Technical setting: A0
Sonic Radiant 100 Sonic Radiant 80 & 60