Omron Varispeed G7 CIMR-G7C Datasheet
Реклама
Реклама
Y203-EN2-02-Katalog.book Seite 249 Mittwoch, 24. Mai 2006 2:22 14
CIMR-G7C
Varispeed G7
World first three level inverter architecture
• 3 level control (400 V class)
• Current vector control and V/F with or without PG
• Torque control (closed loop and open loop)
• Silent operation
• Rotary and stationary autotuning
• High slip braking function
• Energy saving function standard
• LCD operator
• Embedded OMRON PLC functionality with
PLC option card
• Standard RS-485 communications - Modbus
• Fieldbus options: DeviceNet, PROFIBUS, CANOpen,
LONworks, ethernet
• PC configuration tool CX-drive and DriveWorksEZ.
• CE, UL, and cUL marking
• Customised application software
Ratings
• 200 V Class three-phase 0.4 to 110 kW
• 400 V Class three-phase 0.4 to 300 kW
System configuration
3G3IV-PCN329-E
Inverter to PC cable
CX-Drive
DriveWorkEZ
JVOP-160 OY
Digital operator
(LCD display)
JVOP-161-OY
Digital operator
(LED display)
3G3IV-PCN126/326
Digital operator extension cable
Line filter Braking accessories
Monitor option card Feedback speed control card
Varispeed
G7
Communication option cards
PE
R52
C24
U11
C16
C22
R131
C33
U6
T1
U7
C26 R6
U8
C28
10
+ +
U9
R28
U14
Y1
R15
R15
R5
R21
R7
C3
C1
R11
R20
R30
C5
R70
+
U1
C17
R14 +
R120
C35
+
R99
C39
R78
R95
U12
10
10
C11
R102 C12
10
JP5 JP6 C13
RT4
U17
COD
E N o.
R8
SI-N
7360
0-C0
210
C10
TR
2 1
R55
R40
R39
R56
R5
R54
D6
R6
U13
R95
U15
R97
R94
R96 C20
Reference option cards
PLC option card
Varispeed G7 249
Y203-EN2-02-Katalog.book Seite 250 Mittwoch, 24. Mai 2006 2:22 14
Specifications
Type designation
C I M R – G 7 C 4 0 P 4 0
Inverter
G7 series
Specifications
C: European standard
specifications
Voltage
2: 200 V class
4: 400 V class
Protective enclosure
0: Open chassis type (IP00)
1: Enclosed type (IP20 / NEMA1)
Max. applicable motor output
0P4: 0.4 kW
022: 22 kW
300: 300 kW
point
200 V class
1
Model CIMR-G7C
Max. applicable motor output
2
Inverter capacity
Rated current
Max. voltage
Max. output frequency
Rated input voltage and frequency
Allowable voltage fluctuation
Allowable frequency fluctuation
Harmonic wave prevention
DC reactor
12-pulse input kW
20P4 20P7 21P5 22P2 23P7 25P5 27P5 2011 2015 2018 2022 2030 2037 2045 2055 2075 2090 2110
0.4
0.75
1.5
2.2
3.7
5.5
7.5
11 15 18.5
22 30 37 45 55 75 90 110 kVA
1.2
2.3
3.0
4.6
6.9
10 13 19 25 30 37 50 61 70 85 110 140 160
A
3.2
6 8 12 18 27 34 49 66 80 96 130 160 183 224 300 358 415
3-phase, 200/208/220/230/240 V (proportional to input voltage)
Option
Not available
400 Hz (programmable)
3-phase 200/208/220/230/240 V, 50/60 Hz
3
+10%, -15%
±5%
Provided
Available
4
1.
The main circuit of 200 V class inverters uses 2-level control method.
2.
Standard 4-pole motors are used for max. applicable motor output. Choose the inverter model whose rated current is allowable within the motor rated current range.
3.
When using the inverter of 200 V class 30 kW or more with a cooling fan of three-phase 230 V 50 Hz or 240 V 50/60 Hz power supply, a transformer for the cooling fan is required.
4.
A 3-wired transformer is required at 12-pulse input.
400 V class
1
Model CIMR-G7C
40P4 40P7 41P5 42P2 43P7 45P5 47P5 4011 4015 4018 4022 4030 4037 4045 4055 4075 4090 4110 4132 4160 4185 4220 4300
Max. applicable motor output
2
Inverter capacity
Rated current
Max. voltage kW kVA
A
Max. output frequency
Rated input voltage and frequency
Allowable voltage fluctuation
Allowable frequency fluctuation
Harmonic wave prevention
DC reactor
12-pulse input
0.4
0.75 1.5
2.2
3.7
5.5
7.5
11 15 18.5
22 30 37 45 55 75 90 110 132 160 185 220 300
1.4
2.6
3.7
4.7
6.9
11 16 21 26
1.8
3.4
4.8
6.2
9
Option
15
Not available
21 27 34
32
42
40
52
50
65 80 97 128 165 195 240 270 325 370 450 605
3-phase, 380/400/415/440/460/480 V (proportional to input voltage)
400 Hz (programmable)
3-phase 380/400/415/440/460/480 V, 50/60 Hz
+10%, -15%
±5%
61 74 98 130 150 180 210 250 280 340 460
Provided
Available
3
1.
The main circuit of 400 V class inverters uses 3-level control method.
2.
Standard 4-pole motors are used for max. applicable motor output. Choose the inverter model whose rated current is allowable within the motor rated current range.
3.
A 3-wired transformer is required at 12-pulse input.
250 Frequency inverters
Y203-EN2-02-Katalog.book Seite 251 Mittwoch, 24. Mai 2006 2:22 14
Enclosures
Model CIMR-G7C
20P4 20P7 21P5 22P2 23P7 25P5 27P5 2011 2015 2018 2022 2030 2037 2045 2055 2075 2090 2110
Enclosed type
(IEC IP20)
Available as standard Available for option
Not available
Open chassis type
(IEC IP00)
Available by removing the upper and lower cover of
Available as standard enclosed type
Model CIMR-G7C
40P4 40P7 41P5 42P2 43P7 45P5 47P5 4011 4015 4018 4022 4030 4037 4045 4055 4075 4090 4110 4132 4160 4185 4220 4300
Enclosed type
(IEC IP20)
Open chassis type
(IEC IP00)
Available as standard
Available by removing the upper and lower cover of enclosed type
Available for option
Available as standard
Not available
Commom specifications
Model number
CIMRG7C
Control method
Torque characteristics
Speed control range
Speed control accuracy
Speed control response
Torque limits
Torque accuracy
Frequency range
Frequency accuracy
(temperature characteristics)
Frequency setting resolution
Output frequency resolution
Overload capacity and maximum current
Frequency setting signal
Accel/decel time
Braking torque
Main control functions
Motor protection
Instantaneous overcurrent protection
Fuse blown protection
Overload protection
Overvoltage protection
Undervoltage protection
Momentary power loss ride through
Cooling fin overheating
Stall prevention
Grounding protection
Charge indicator
Ambient operating temperature
Ambient operating humidity
Storage temperature
Application site
Altitude
Vibration
Specification
Sine wave PWM Closed loop vector control, open loop vector control 1&2, V/f control, V/f with PG control
150% at 0.3 Hz (open loop vector control 2)
150% at 0rpm (closed vector control)
1:200 (open loop vector control 2)
1:1000 (closed loop vector control)
± 0.2% (open loop vector control)
± 0.02% (closed loop vector control)
(25
°
C ± 10
°
C)
10 Hz (open loop vector control 2)
30 Hz (control with PG)
Provided (4 quadrant steps can be changed by constant settings.) (Vector control)
± 5%
0.01 to 400 Hz
Digital references: ± 0.01% (-10
°
C to +40
°
C)
Analog references: ± 0.1% (25
°
C ±10
°
C)
Digital references: 0.01 Hz
Analog references: 0.025/50 Hz (11 bits plus sign)
0.001 Hz
150% of rated output current for 1 minute
200% of rated output current for 0.5 second
0 to +10 V, -10 to +10 V, 4 to 20 mA, pulse train
0.01 to 6000.0 s (4 selectable combinations of independent acceleration and deceleration time settings)
Approximately 20%
(Approximately 125% with braking resistor option, braking transistor built into Inverters of 15 kW or less)
Restarting after momentary power loss, speed search, overtorque/undertorque detection, torque limits, 17-speed control
(maximum), 4 acceleration and deceleration times, S-curve acceleration/deceleration, 3-wire control, auto-tuning
(rotational or stationary), dwell function, cooling fan ON/OFF control, slip compensation, torque compensation, auto-restart after fault, jump frequencies, upper and lower limits for frequency references, DC braking for starting and stopping, high-slip braking, advanced PID control, energy-saving control, MEMOBUS communications
(RS-485/422, 19.2 kbps maximum), 2 motor parameter sets, fault reset and parameter copy function.
Protection by electronic thermal overload relay.
Stops at approx. 200% of rated output current.
Stops for fuse blown.
150% of rated current for 1 minute
200% of rated current for 0.5 second
200 Class Inverter: stops when main-circuit DC voltage is above 410 V.
400 Class Inverter: stops when main-circuit DC voltage is above 820 V.
200 Class Inverter: stops when main-circuit DC voltage is below 190 V.
400 Class Inverter: stops when main-circuit DC voltage is below 380 V.
By selecting the momentary power loss method, operation can be continued if power is restored within 2 s.
Protection by thermistor.
Stall prevention during acceleration, deceleration and running independently.
Protection by electronic circuits.
Illuminates when the main circuit DC voltage is approx. 10 VDC or more.
-10
°
C to 40
°
C (enclosed wall-mounted type)
-10
°
C to 45
°
C (open chassis type)
95% max. (with no condensation)
- 20
°
C to + 60
°
C (short-term temperature during transportation)
Indoor (no corrosive gas, dust, etc.)
1000 m max.
10 to 20 Hz, 9.8 m/s
2
max.; 20 to 50 Hz, 2 m/s
2
max
Varispeed G7 251
Y203-EN2-02-Katalog.book Seite 252 Mittwoch, 24. Mai 2006 2:22 14
Dimensions
Open chassis type (IEC IP00)
W1
4-d
(5) W (5)
Fig 1
(5) D
T1
D1
Voltage
Max. applicable motor output kW
0.4
0.75
Inverter
CIMR-G7C
------
------
-----1.5
2.2
3.7
------
------
5.5
7.5
11
15
18.5
22
30
37
45
55
75
------
------
2011
2015
2018
2022
2030
2037
2045
2055
2075
90
110
0.4
0.75
1.5
2.2
4.0
5.5
7.5
11
15
2090
2110
------
------
------
------
------
------
------
4011
4015
55
75
90
110
132
160
185
220
300
18.5
22
30
37
45
4018
4022
4030
4037
4045
4055
4075
4090
4110
4132
4160
4185
4220
4300
Fig
1
1
W
250
275
375
275
325
450
710
916
450
500
575
500
575
H D
Dimensions in mm
W1
325
370
445
540
730
H1
700
820
855
1270
1440
H2
12.5
15
45.8
15
D1
130
140
126
T1 d
Approx. weight kg
Not available please use the IP20 type removing the upper and lower cover
400
450
600
725
850
885
450
550
258
258
298
328
348
358
378
258
283
725
850
916
1305
1475
415
348
358
378
195
220
250
325
370
445
220
260
385
435
575
700
820
855
7.5
12.5
15
100
130
140
2.3
3.2
4.5
M6
M10
M12
Not available please use the IP20 type removing the upper and lower cover
435
535
7.5
100
105
2.3
3.2
4.5
M6
M10
M12
21
24
57
63
86
87
108
150
26
37
90
91
109
127
165
175
263
280
415
Cooling method
Fan cooled
Fan cooled
252 Frequency inverters
Y203-EN2-02-Katalog.book Seite 253 Mittwoch, 24. Mai 2006 2:22 14
Enclosed type (IEC IP20)
W1
G7C20P41 to G7C25P51
G7C40P41 to G7C45P51
4-d
G7C27P51 to G7C20181
G7C47P51 to G7C40181
4-d
G7C20221 to G7C20751
G7C40221 to G7C41601
W1
4-d
G7C4185 to G7C4300
W
Fig 1
3
D1
D
T1
W1
W
Fig 2
3 D
T1
D1
(5)
W
(5)
Fig 3
(5) D
T1
D1
Fig 4
Voltage
4011
4015
4018
4022
4030
4037
4045
4055
4075
4090
4110
4132
4160
4185
4220
4300
2015
2018
2022
2030
2037
2045
2055
2075
2090
2110
40P4
40P7
41P5
42P2
43P7
45P5
47P5
Inverter
CIMR-G7C
20P4
20P7
21P5
22P2
23P7
25P5
27P5
2011
11
15
18.5
22
30
37
45
55
75
90
110
132
160
185
220
300
Max. applicable motor output kW
0.4
0.75
1.5
2.2
3.7
5.5
7.5
11
55
75
90
110
0.4
15
18.5
22
30
37
45
0.75
1.5
2.2
3.7
5.5
7.5
Fig
1
2
3
1
2
3
4
W
140
H
280
D
157
177
Dimensions in mm
W1
126
H1
266
200 300
240
250
275
375
350
400
450
600
207
450
500
575
725
850
885
258
298
328
348
358
378
197 186
216
195
220
250
285
335
385
435
575
325
370
445
700
820
855
140
200
240
275
325
450
500
575
280
300
350
450
550
725
850
916
157
177
197
207
258
283
348
358
378
710
916
1305
1475
415
126
186
216
220
260
325
370
445
540
730
266
285
335
435
535
700
820
855
1270
1440
H2
7
8
7.5
12.5
15
7
8
7.5
12.5
15
45.8
15
D1
39
59
65.5
78
100
130
140
39
59
65.5
78
100
105
130
140
126
T1
5
2.3
d
M5
M6
3.2
M10
4.5
M12
5
2.3
M5
M6
3.2
M10
4.5
M12
Approx. weight kg
Cooling method
3
Self cooled
4
6
7
11
21
24
57
63
86
87
108
150
3.5
4.5
7
10
26
37
90
91
109
127
165
175
263
280
415
Fan cooled
Self cooled
Fan cooled
Varispeed G7 253
Y203-EN2-02-Katalog.book Seite 254 Mittwoch, 24. Mai 2006 2:22 14
Filters
Footprint / Flat filters
1.
200 V
400 V
Model
3G3RV-PFI2035-SE
3G3RV-PFI2060-SE
3G3RV-PFI2100-SE
3G3RV-PFI3010-SE
3G3RV-PFI3018-SE
3G3RV-PFI3021-SE
3G3RV-PFI3035-SE
3G3RV-PFI3060-SE
3G3RV-PFI3410-SE
1
3G3RV-PFI3600-SE
1
3G3RV-PFI3800-SE
1
A
330
355
408
330
330
355
355
408
386
386
564
B
141
206
236
141
141
206
206
236
115
135
160
Flat filters are not possible to be mounted as footprint filters.
C
46
60
80
46
46
50
50
65
260
260
300
D
281
302
355
281
281
302
302
355
306
306
516
Bookform filters
E
313
336
390
313
313
336
336
390
240
240
420
Dimensions
F
115
175
205
115
115
175
175
205
235 12.0
G
5.5
6.5
6.5
5.5
5.5
6.5
6.5
6.5
235
275
12.0
9.0
H
M5
M6
M6
M5
M5
M4
M5
M6
M12
M12
M12
I
23
30
40
23
23
25
25
32.5
-
-
-
J
126
186
216
126
126
186
186
216
-
-
-
K
266
285
335
266
266
285
285
335
-
-
-
L
M5
M6
M6
M5
M5
M5
M6
M6
-
-
-
254
200 V
400 V
Model
3G3RV-PFI2130-SE
3G3RV-PFI2160-SE
3G3RV-PFI2200-SE
3G3RV-PFI3070-SE
3G3RV-PFI3100-SE
3G3RV-PFI3130-SE
3G3RV-PFI3170-SE
3G3RV-PFI3200-SE
A
366
451
610
331
326
370
451
610
B
180
170
240
185
150
180
170
240
C
90
120
130
80
90
90
120
130
Dimensions
D
280
350
480
300
240
280
350
480
E
310
380
518
329
270
310
380
518
F
65
102
90
55
65
65
102
90
G
6.5
6.5
8.2
6.5
6.5
6.5
6.5
8.3
H
M10
M10
M10
M6
M10
M10
M10
M10
Frequency inverters
Y203-EN2-02-Katalog.book Seite 255 Mittwoch, 24. Mai 2006 2:22 14
Braking unit
Model CDBR-2015 B, -2022 B, -4030B, -4045 B
4-M4 MTG Holes 72 66.5
30 or more
38
128
140
38
3-lead Wire Inlet
(20 Dia. Rubber Bush)
30 or more
Weight 1.8 Kg
114.5
138.5
Braking resistor unit (inverter-mounted type)
Weight : 0.2 kg
Model ERF-150WJ_
Model CDBR-4220 B
4-M6
MTG Holes
210
Main Circuit
Terminal
M6
30 or more
156.5
118.5
50
210
250
30 or more
Weight 12 Kg
104
Lead Wire Inlet
(28 Dia. Rubber Bush)
2-lead Wire Inlet
(35 Dia. Rubber Bush)
111
156
200
182
170
150
Model CDBR-2110 B
4-M6
MTG Holes
140
Main Circuit
Terminal
M6
100
30 or more
59 50
140
180
30 or more
Weight 8.5 Kg
104
Lead Wire Inlet
(28 Dia. Rubber Bush)
2-lead Wire Inlet
(35 Dia. Rubber Bush)
111
156
200
Note: Prepare mounting screws
(2-M4x8 tapped screws).
Screws 8mm or more and general
metric screws cannot be used.
44
Braking resistor unit (separately-installed type)
MTG Screw
MTG Screw
30 or more
Voltage
220 V class
400 V class
Model
LKEB-_
20P7
21P5
22P2
23P7
25P5
25P5
40P7
41P5
42P2
43P7
45P5
47P5
A
105
130
130
130
250
250
105
130
130
130
250
250
C
A 30 or more
150 50 or more
B
275
350
350
350
350
350
275
350
350
350
350
350
Dimensions in mm
C
50
75
75
75
200
200
50
75
75
75
200
200
D
260
335
335
335
335
335
260
335
335
335
332
332
MTG Screw
M5 x 3
M5 x 4
M5 x 4
M5 x 4
M6 x 4
M6 x 4
M5 x 3
M5 x 4
M5 x 4
M5 x 4
M6 x 4
M6 x 4
Weight kg
3.0
4.5
4.5
5.0
7.5
8.5
3.0
4.5
4.5
5.0
7.5
8.5
Voltage
220 V class
400 V class
Model
LKEB-_
2011
2015
2018
2022
4011
4015
4018
4022
4030
4037
4045
A
266
356
446
446
350
350
446
446
356
446
446
C
A 50 or more
260
B
543
543
543
543
412
412
543
543
956
956
956
Dimensions in mm
C
246
336
426
426
330
330
426
426
336
426
426
D
340
340
340
340
325
325
340
340
740
740
740
MTG Screw
M8 x 4
M8 x 4
M8 x 4
M8 x 4
M6 x 4
M6 x 4
M8 x 4
M8 x 4
M8 x 4
M8 x 4
M8 x 4
Weight kg
10
15
19
19
16
18
19
19
25
33
33
Varispeed G7 255
Y203-EN2-02-Katalog.book Seite 256 Mittwoch, 24. Mai 2006 2:22 14
Attachments
Heatsink external mounting attachment
The Varispeed G7 inverters under the 200/400 V class 15 kW or less need this attachment for mounting the heatsink externally. This attachment expands the outer dimensions of the width and height of the inverter. (Attachment is not required for inverters of 18.5 kW or more.)
Mounting panel Wall
W1
W D1 D2
D3 or more
CIMR-
G7C
20P4
20P7
21P5
22P2
23P7
25P5
27P5
2011
2015
40P4
40P7
41P5
42P2
43P7
45P5
47P5
4011
4015
Attachment order code
W H
Dimensions in mm
W1 H1 D1 D2 D3
72616 -EZZ08676A 155 302 126 290 122.6
37.4
40
57.4
60
72616-EZZ08676B 210 330 180 316 136.1 63.4
70
72616-EZZ08676C 250 392 216 372 133.6 76.4
85
37.4
40
72616-EZZ08676A 155 302 126 290 122.6
57.4
60
72616-EZZ08676B 210 330 180 316 136.1 63.4
70
72616-EZZ08676C 250 392 216 372 133.6 76.4
85
Panel cut for external mounting of cooling fin (heatsink)
CIMR-
G7C
4015
4018
4022
4030
4037
4045
4055
4075
4090
4110
4132
4160
4185
4220
4300
2090
2100
40P4
40P7
41P5
42P2
43P7
45P5
47P5
4011
20P4
20P7
21P5
22P2
23P7
25P5
27P5
2011
2015
2018
2022
2030
2037
2045
2055
2075
Fig
1
2
1
2
3
W H
Dimensions in mm
W1 (W2) (W3) H1 (H2) (H3)
155 302 126
210 330 180
250 392 216
250 400 195
275 450 220
375 600 250
6
8.5
24.5
450 725 325
500 850 370 57
575 885 445
155 302 126
210 330 180
250 392 216
275 450 220
325 550 260
500 850 370
575 925 445
8.5
6.5
8.5
3
54.5
8
55
6
8.5
24.5
450 725 325 54.5
57
55
8
10
8.5
6.5
8.5
3
8
10
290 9.5
316 9
372 9.5
385
435
575
855
316
435
535
820
8
15
700 13.5
820
19
290 9.5
9
372 9.5
8
19
895 see 1
6
7
10
7.5
A B
233 353
244 369
269 419
12.5
359 545
434 673
15
6
7
10
7.5
15
484 782
M10
555 817
M12
269 419
484 782
M6
M6
15 555 817
M12
4 710 1305 540 76.5
8.5 1270 21.5 see
1
693 1227
5 916 1475 730 72.5 20.5 1440 21.5 see 1 875 1397 d
138 271 M5
197 298
138 271 M5
197 298
233 353
309 519
700 13.5 12.5 434 673 M10
1.The sizes are different between the top and the bottom. Refer to figs. 3 to 5
256 Frequency inverters
Y203-EN2-02-Katalog.book Seite 257 Mittwoch, 24. Mai 2006 2:22 14
Installation
Standard connections
3-phase
Power supply
200 to 240 V
50/60 Hz
L1
L2
L3
PE
Main contactor and fuses
T
Multi-function digital inputs
[Factory setting]
Forward run/stop
Reverse run/stop
External fault
Full reset
Multi-step speed setting 1
Multi-step speed setting 2
Jog reference
External base
Block reference
Multi-step speed setting 3
Multi-step speed setting 4
Accel/decel time 1
Emergency stop
(NO contact)
Line filter
DC reactor to improve inputs power factor (optional)
Braking resistor (option)
U X
Short-circuit bar
1
R/L1
S/L2
T/L3
2 B1
Varispeed G7
CIMR-G7C47P5
B2
U/T1
V/T2
W/T3
S1
S2
S3
S4
S5
S10
S11
S12
SN
S6
S7
S8
S9
SC
SP
24V
E(G)
MA
MB
MC
Fault contact output
250 VAC, 1A or less
30 VDC, 1A or less
M1
M2
M3
M4
M5
M6
Run signal at
Factory settings
Open collector output 1
[Zero speed signal at factory setting]
Open collector output 2
[Frequency agreement signal at factory setting]
E(G)
Open collector output 3
[Ready to operate at factory setting]
Open collector output 4
[Frequency (FOUT) detection 2 at factory setting]
M
Motor
Multi-function contact output
250 VAC, 1A or less
30 VDC, 1A or less
Multi-function open collector output
48 VDC 50mA or less
2k•
Analog input setting adjustment
3
-10 to 10 V
1
2
-10 to 10 V/
4 to 20 mA
2k•
-10 to 10 V
P
P
P
MEMOBUS communication
RS-485/422
P
P
R+
R-
S+
S-
IG
RP
Pulse train input [Default:
Frequency reference input]
0 to 32 kHz
+V Analog input power supply
+15V,, 20 mA
A1
Analog input 1 Master frequency reference
0 to +10 V (20 k•)
Multi-functions analog input 2
A2
[Default: Frequency bias
4 to 20 mA (250•)]
A2 Multi-functions analog input 3
[Default: Auxiliary Frequency
Reference 0 to 10 V (20•)]
AC
-V
0V
Analog input power supply
-15 V, 20 mA
Terminating resistance
MP
AC
FM
AM
AC
Pulse train output
0 to 32kHz (2.2 k•)
[Output frequency at factory setting]
Frequency master adjusting potentiometer
20 k•
+
FM
-
Multi-function analog output 1
(-10 to +10V, 2mA)
[Output frequency af factory setting 0 to 10 V]
Ammeter adjusting potentiometer
20 k
Ω
+
-
AM
Multi-function analog output 2
(-10 to +10 V, 2 mA)
[Output current at factory o to +10 V]
Shielded cable P
Shielded twisted pair cable
Varispeed G7 257
Y203-EN2-02-Katalog.book Seite 258 Mittwoch, 24. Mai 2006 2:22 14
Main circuit
Voltage
Model CIMR-G7C
Max. applicable motor output
R/L1
S/L2
T/L3
R1/L11
S1/L21
T1/L31
U/T1
V/T2
W/T3
B1
B2
20P4 to 2015
0.4 to 15 kW
Main circuit input power supply
---
200 V
2018, 2022
18.5 to 22 kW
2030 to 2110
30 to 110 kW
Main circuit input power supply
R-R1, S-S1 and T-T1 have been wired before shipment (see P59).
Inverter output
40P4 to 4015
0.4 to 15 kW
Main circuit input power supply
---
400 V
4018 to 4045
18.5 to 45 kW
Main circuit input power supply
R-R1, S-S1 and T-T1 have been wired before shipment
Inverter output
4055 to 4300
55 to 300 kW
1
2
3
/ l
2 r/ l
1
200 /
400 / l l
2
2
200
400
Braking resistor unit
•DC reactor
( 1- 2)
•DC power supply
1
( 1 - )
---
------
------
------
•DC power supply
( 1- 2)
1
•Braking unit
( 3 - )
Cooling fan power supply
2
Braking resistor unit
•DC reactor
( 1- 2)
•DC power supply
1
( 1 - )
---
---
------
•DC power supply
( 1- 2)
1
•Braking unit
( 3 - )
---
Cooling fan power supply
3
Ground terminal (10
Ω
or less) Ground terminal (100
Ω
or less)
1.
1 - DC power input does not conform to UL/c-UL listed standard.
2.
Cooling fan power supply r/ l
1
- / l
2
: 200 to 220 VAC 50 Hz, 200 to 230 VAC 60 Hz
(A transformer is required for 230 V 50 Hz or 240 V 50/60 Hz power supply.)
3.
Cooling fan power supply r/ l
1
- 200 / l
2
200: 200 to 220 VAC 50 Hz, 200 to 230 VAC 60 Hz, r/ l
1
- 400 / l
2
400: 380 to 480 VAC 50/60 Hz
CIMR-G7C20P4 to 2015
Main circuit configuration
CIMR-G7C2018, 2022 CIMR-G7C2030 to 2110
CIMR-G7C40P4 to 4015 CIMR-G7C4018 to 4045 CIMR-G7C4055 to 4300
1. For 200 V class filters, consult with standard OMRON supplier.
258 Frequency inverters
Y203-EN2-02-Katalog.book Seite 259 Mittwoch, 24. Mai 2006 2:22 14
Control circuit
Type No.
S1
S2
S3
S4
S5
A3
AC
E(G)
P1
S6
S7
S8
S9
S10
S11
S12
SC
+V
–V
A1
A2
Signal name
Forward run/stop signal
Reverse run/stop signal
Multi-function input selection 1
Multi-function input selection 2
Multi-function input selection 3
Multi-function input selection 4
Multi-function input selection 5
Multi-function input selection 6
Multi-function input selection 7
Multi-function input selection 8
Multi-function input selection 9
Multi-function input selection 10
Sequence control input common
+15 V power supply output
–15 V power supply output
Master speed frequency reference
Multi-function analog input
Master speed frequency reference
Analog common
Connection to shield wire and option ground wire
Multi-function PHC output 1
Multi-function PHC output 2
Photo-coupler output common
Function
Forward run at “closed”, stop at “open”
Reverse run at “closed”, stop at “open”
Factory setting: external fault at “closed”
Factory setting: fault reset at “closed”
Factory setting: multi-step speed setting 1 is valid at
“closed”
Factory setting: multi-step speed setting 2 is valid at
“closed”
4 to 20 mA/100%, -10 to +10 V/ -100 to +100%,
0 to +10 V/ 100%
Factory setting: added to the terminal A1 (H3-09=0)
Signal level
Factory setting: JOG run at “closed”
Factory setting: external baseblock at “closed”
Factory setting: multi-step speed setting 3 is valid at
“closed”
Factory setting: multi-step speed setting 4 is valid at
“closed”
Factory setting: accel/decel time setting 1 is valid at
“closed”
Factory setting: emergency stop (NO contact) is valid at
“closed”
–
Photo-coupler input +24 VDC
8 mA isolation
For analog reference +15 V power supply
For analog reference -15 V power supply
-10 to +10 V/ -100 to +100%, 0 to +10 V/ 100%
+15 V (allowable current
20 mA max.)
-15 V (allowable current
20 mA max.)
-10 to +10 V, 0 to +10V
(input impedance 20 k)
4 to 20 mA
(input impedance 250
Ω
)
-10 to +10 V/ -100 to +100%, 0 to +10 V/ 100%
Factory setting: preset frequency reference
0 V
0 to +10 V
(input impedance 20 k
Ω
)
–
– –
Factory setting: zero speed signal
“Closed” at or below zero speed level (b2-01)
Factory setting: frequency agreement
“Closed” within ±2Hz of setting frequency
–
+48 VDC 50 mA or less
Multi-function PHC output 3 Factory setting: ready to operate (READY).
P2
PC
P3
C3
P4
C4
MA
MB
MC
M1
M2
FM
AM
AC
RP
MP
R+
R-
S+
S-
IG
Multi-function PHC output 4 Factory setting: frequency (FOUT) detection 2
Fault output (NO contact) Fault at “closed” between terminals MA and MC
Fault output (NC contact)
Rely contact output common
Multi-function contact output
(NO contact)
Fault at “open” between terminals MB and MC
–
Factory setting: run signal
Running at “closed” between terminals M1 and M2
Multi-function analog monitor 1 Factory setting: output frequency 0 to 10 V/100% freq.
Multi-function analog monitor 2
Factory setting: current monitor 5 V / inverter rated current
Analog common
Multi-function pulse input
Multi-function pulse monitor
–
Factory setting: frequency reference input (H6-01=0)
Factory setting: output frequency (H6-06=2)
Dry contact, contact capacity
250 VAC 1 A or less
30 VDC 1 A or less
0 to +10 VDC ±5%
2 mA or less
MEMOBUS communications input
MEMOBUS communications output
Signal common
For 2-wire RS-485, short R+ and S+ as well as R- and S-.
–
0 to 32 kHz (3 k
Ω
)
0 to 32 kHz (2.2 k
Ω
)
Differential input, photocoupler isolation
Differential input, photocoupler isolation
–
Varispeed G7 259
Y203-EN2-02-Katalog.book Seite 260 Mittwoch, 24. Mai 2006 2:22 14
Remove the upper and lower covers for the models of 15 kW or less in 200 V and 400 V classes.
When using open chassis type inverters of 200 V/400 V
22 kW or more, secure spaces for eyebolts and wiring of the main circuit.
55 ˚C
Internal heatsink
Upper cover
Upper part air temperature
-10 to 55 ˚C
Heatsink
Open chassis type inverter
Upper cover
Heatsink
50 mm or more
120 mm or more
Air
Lower cover
Inverter inlet temperature
-10 to 45 ˚C
45 ˚C
Peripheral temperature 40 ˚C
Lower cover
Cover MTG screw
30 mm or more
50 mm or more
Side spaces
30 mm or more
120 mm or more
Air
Top and bottom spaces
Inverter heat loss
200 V class
Model CIMR-G7C 20P4 20P7 21P5 22P2 23P7 25P5 27P5 2011 2015 2018 2022 2030 2037 2045 2055 2075 2090 2110
Inverter capacity kVA 1.2
2.3
3.0
4.6
6.9
10 13 19 25 30 37 50 61 70 85 110 140 160
Rated current A 3.2
6 8 12 18 27 34 49 66 80 96 130 160 183 224 300 358 415
Fin W 21 43 58 83 122 187 263 357 473 599 679 878 1080 1291 1474 2009 1660 2389
36 42 47 53 64 87 112 136 174 242 257 362 434 510 607 823 871 1194 Inside unit W
Total heat loss W
Fin coding
57 85
Self cooled
105 136 186 274 375 493 647 839 936 1240 1514 1801 2081 2832 2531 3583
Fan cooled
400 V class
Model CIMR-G7C 40P4 40P7 41P5 42P2 43P7 45P5 47P5 4011 4015 4018 4022 4030 4037 4045 4055 4075 4090 4110 4132 4160 4185 4220 4300
Inverter capacity kVA 1.4
2.6
3.7
4.7
6.9
11 16 21 26 32 40 50 61 74 98 130 150 180 194 230 280 340 460
Rated current A 1.8
3.4
4.8
6.2
9 15 21 27 34 42 52 65 80 97 128 165 195 240 255 302 370 450 605
Fin W 10 21 33 41 76 132 198 246 311 354 516 633 737 929 1239 1554 1928 2299 2612 3614 4436 5329 6749
Inside unit W 39 44 46 49 64 79 106 116 135 174 210 246 285 340 488 596 762 928 1105 1501 1994 2205 2941
Total heat loss W 49 65 79 90 140 211 304 362 446 528 726 879 1022 1269 1727 2150 2690 3227 3717 5115 6430 7534 9690
Fin coding Self cooled Fan cooled
Connections for braking units Connections for braking resistors
P B
Braking resistor
MCCB
3-phase
Power
Supply
R
S
T
MC
B1 B2
R
S
T
Varispeed G7
U
V
W
· Set constant L8-01 to 1
(mounting type braking resistor protection enabled).
· Set sequence to shutt off the power side at inverter fault contact output.
Motor
IM
3
Varispeed G7
1
2
Braking resistor overload relay trip contact
(thermal relay trip contact)
1 2
Braking
Resistor
Unit
P B
Braking resistor overload relay trip contact
(thermal relay trip contact)
1 2
Braking resistor unit *3
P B
MASTER
SLAVE
MASTER
SLAVE
+15
5
6
P
2
1 Braking unit 2* 2
Braking unit 1 3 4
Cooling fin overheat contact
(Thermoswitch contact)
3 4
Cooling fin overheat contact
(Thermoswitch contact)
260 Frequency inverters
Y203-EN2-02-Katalog.book Seite 261 Mittwoch, 24. Mai 2006 2:22 14
AC reactor
Max. applicable
motor output kW
0.4
0.75
1.5
2.2
3.7
5.5
7.5
11
15
18.5
22
30
37
45
55
75
90
110
Connection example
MCCB
AC reactor
200 V Class
Current value
A
2.5
5
120
160
200
240
280
360
500
500
40
60
80
90
10
15
20
30
Varispeed G7
Inductance mH
4.2
2.1
0.09
0.07
0.05
0.044
0.038
0.026
0.02
0.02
1.1
0.71
0.53
0.35
0.265
0.18
0.13
0.12
Motor
Application example
Power supply capacity (kVA)
AC reactor required for power supply harmonics
AC reactor not required
Max. applicable motor output kW
0.4
0.75
1.5
2.2
3.7
5.5
7.5
11
15
18.5
22
30
37
45
55
75
90/110
132/160
185
220
300
Inverter capacity (kVA)
400 V class
Current value
A
1.3
2.5
60
80
90
120
150
200
250
330
20
30
40
50
5
7.5
10
15
490
660
DC reactor
MCCB
DC reactor
⊕ ⊕
Varispeed G7
Max. applicable motor output kW
0.4
0.75
1.5
2.2
3.7
5.5
7.5
11
15
18.5
22 to 110
Take off the common bar between G1 and G2, and wire as shown in the diagram.
200 V class
Current value
A
5.4
18
36
72
90
Built-in
Inductance mH
8
3
1
0.5
0.4
Motor
Power supply capacity
(kVA)
Max. applicable
motor output kW
0.4
0.75
1.5
2.2
3.7
5.5
7.5
11
15
18.5
22 to 300
With reactor for power supply coordination
Without reactor
Inverter capacity (kVA)
400 V class
Current value
A
3.2
5.7
12
23
33
47
Built-in
Inductance mH
28
11
6.3
3.6
1.9
1.3
Inductance mH
18.0
8.4
0.36
0.26
0.24
0.18
0.15
0.11
0.09
0.06
4.2
3.6
2.2
1.42
1.06
0.7
0.53
0.42
0.04
0.03
Varispeed G7 261
Y203-EN2-02-Katalog.book Seite 262 Mittwoch, 24. Mai 2006 2:22 14
4015
4018
4022
4030
4037
4045
4055
4075
4090
4110
4132
4160
4185
4220
4300
40P4
40P7
41P5
42P2
43P7
44P0
45P5
47P5
4011
Fuse installation
To protect the inverter, it is recommended to use semiconductor fuses as shown in the table below
Inverter type
2018
2022
2030
2037
2045
2055
2075
2090
2110
20P4
20P7
21P5
22P2
23P7
25P5
27P5
2011
2015
240
240
240
240
240
240
240
240
240
Voltage (V)
240
240
240
240
240
240
240
240
240
FUSE
150
180
240
300
350
450
550
600
700
Current (A)
10
15
20
30
40
60
80
100
130
480
480
480
480
480
480
480
480
480
480
480
480
480
480
480
480
480
480
480
480
480
480
480
480
60
70
90
110
140
160
220
300
330
400
450
540
750
750
1000
20
25
30
40
50
5
10
10
15
16~660
19~660
46~660
78~660
110~660
220~660
240~900
320~900
1000~18000
1500~4100
530~5800
1130~5800
1700~5800
2000~13000
3000~13000
6800~55000
3800~55000
12000~23000
18000~64000
28000~25000
40000~250000
63000~400000
63000~400000
94000~920000
I
2 t (A
2 s)
12~25
23~55
34~98
82~220
220~610
290~1300
450~5000
1200~7200
1800~7200
870~16200
1500~23000
2100~19000
2700~55000
4000~55000
7100~64000
11000~64000
13000~83000
13000~83000
262 Frequency inverters
Y203-EN2-02-Katalog.book Seite 263 Mittwoch, 24. Mai 2006 2:22 14
Ordering information
3G3IV-PCN329-E
Inverter to PC cable
CX-Drive
DriveWorkEZ
G G
Line filter
JVOP-160 OY
Digital operator
(LCD display)
G
JVOP-161-OY
Digital operator
(LED display)
G
Braking accessories
3G3IV-PCN126/326
Digital operator extension cable
G
A
Monitor option card
B
Varispeed G7
Feedback speed control card
C
Varispeed
G7
Communication option cards
D
PE
R52
C24 U11
C16
33 + +
U9
C3
C1
C26 R6
U8
C28
10
R28
R11 C21
R70
R120
C22
R131 U14
Y1
R15
R15
R5
R25
R21
R7
R30
C5
C17
R14 +
C2
+
C35
R99
C11
10 10
R102
C12
10
JP5 JP6
C13
R78
U12
RT4
U17
CODE
No.
R8
SI-N
736
00-C
C10
0210
2 1 R110
R55
R54
R57
R5
R39 R40
U13
R95
U15
R96
R97
R94
R6
D6
Reference option cards
E
H
PLC option card
F
200 V
Inverter Model
Varispeed G7
CIMR-G7C20P4
CIMR-G7C20P7
CIMR-G7C21P5
CIMR-G7C22P2
CIMR-G7C23P7
CIMR-G7C25P5
CIMR-G7C27P5
CIMR-G7C2011
CIMR-G7C2015
CIMR-G7C2018
CIMR-G7C2022
CIMR-G7C2030
CIMR-G7C2037
CIMR-G7C2045
CIMR-G7C2055
CIMR-G7C2075
CIMR-G7C2090
CIMR-G7C2110
Type
3G3RV-PFI3010-SE
3G3RV-PFI3018-SE
3G3RV-PFI2035-SE
3G3RV-PFI2060-SE
3G3RV-PFI2100-SE
Line Filters
EN55011
Class
B, 25 m
A, 100 m
B, 25 m
A, 100 m
B, 25 m
A, 100 m
B, 25 m
A, 100 m
B, 25 m
A, 100 m
Current
(A)
10
18
35
60
100
3G3RV-PFI2130-SE A, 100 m
3G3RV-PFI2160-SE A, 100 m
3G3RV-PFI2200-SE A, 100 m
3G3RV-PFI3410-SE A, 100 m
3G3RV-PFI3600-SE A, 100 m
130
160
200
400
600
Weight
(kg)
1.2
1.3
1.4
3
4.9
4.3
6.0
11.0
8.6
11.0
400 V
Inverter Model
Varispeed G7
CIMR-G7C40P4
CIMR-G7C40P7
CIMR-G7C41P5
CIMR-G7C42P2
CIMR-G7C43P7
CIMR-G7C44P0
CIMR-G7C45P5
CIMR-G7C47P5
CIMR-G7C4011
CIMR-G7C4015
CIMR-G7C4018
CIMR-G7C4022
CIMR-G7C4030
CIMR-G7C4037
CIMR-G7C4045
CIMR-G7C4055
CIMR-G7C4075
CIMR-G7C4090
CIMR-G7C4110
CIMR-G7C4132
CIMR-G7C4160
CIMR-G7C4185
CIMR-G7C4220
CIMR-G7C4300
Type
3G3RV-PFI3010-SE
Line Filters
EN55011
Class
Current
(A)
B, 25 m
A, 100 m
10
3G3RV-PFI3018-SE
3G3RV-PFI3021-SE
3G3RV-PFI3035-SE
3G3RV-PFI3060-SE
3G3RV-PFI3070-SE
B, 25 m
A, 100 m
B, 25 m
A, 100 m
B, 25 m
A, 100 m
B, 25 m
A, 100 m
B, 25 m
A, 100 m
3G3RV-PFI3100-SE A, 100 m
3G3RV-PFI3130-SE A, 100 m
3G3RV-PFI3170-SE A, 100 m
3G3RV-PFI3200-SE A, 100 m
3G3RV-PFI3410-SE A, 100 m
3G3RV-PFI3600-SE A, 100 m
3G3RV-PFI3800-SE A, 100 m
18
21
35
60
70
100
130
170
250
400
600
800
Weight
(kg)
1.2
1.3
1.8
2.2
4.0
3.4
4.5
4.7
6.0
11
8.6
11
31.0
Varispeed G7 263
Y203-EN2-02-Katalog.book Seite 264 Mittwoch, 24. Mai 2006 2:22 14
A
Line filters
200 V
Inverter model
Varispeed G7
CIMR-G7C20P4
CIMR-G7C20P7
Line filters
Type
3G3RV-PFI3010-SE
CIMR-G7C21P5 3G3RV-PFI3018-SE
CIMR-G7C22P2
CIMR-G7C23P7
CIMR-G7C25P5
CIMR-G7C27P5
CIMR-G7C2011
3G3RV-PFI2035-SE
3G3RV-PFI2060-SE
CIMR-G7C2015
CIMR-G7C2018
3G3RV-PFI2100-SE
CIMR-G7C2022 3G3RV-PFI2130-SE
CIMR-G7C2030 3G3RV-PFI2160-SE
CIMR-G7C2037
3G3RV-PFI2200-SE
CIMR-G7C2045
CIMR-G7C2055
CIMR-G7C2075 3G3RV-PFI3410-SE
CIMR-G7C2090
CIMR-G7C2110 3G3RV-PFI3600-SE
EN55011 class
B, 25 m
A, 100 m
B, 25 m
A, 100 m
B, 25 m
A, 100 m
B, 25 m
A, 100 m
B, 25 m
A, 100 m
A, 100 m
A, 100 m
A, 100 m
A, 100 m
A, 100 m
Current
(A)
10
Weight
(kg)
1.2
18
35
60
100
130
160
200
400
600
1.3
1.4
3
4.9
4.3
6.0
11.0
8.6
11.0
400 V
Inverter model
Varispeed G7
CIMR-G7C40P4
CIMR-G7C40P7
CIMR-G7C41P5
CIMR-G7C42P2
CIMR-G7C43P7
CIMR-G7C44P0
3G3RV-PFI3010-SE
3G3RV-PFI3018-SE
CIMR-G7C45P5 3G3RV-PFI3021-SE
CIMR-G7C47P5
CIMR-G7C4011
CIMR-G7C4015
CIMR-G7C4018
CIMR-G7C4022
CIMR-G7C4030
CIMR-G7C4037
CIMR-G7C4045
CIMR-G7C4055
CIMR-G7C4075
CIMR-G7C4090
CIMR-G7C4110
CIMR-G7C4132
CIMR-G7C4160
CIMR-G7C4185
CIMR-G7C4220
CIMR-G7C4300
Line filters
Model
3G3RV-PFI3035-SE
3G3RV-PFI3060-SE
3G3RV-PFI3070-SE
3G3RV-PFI3100-SE
3G3RV-PFI3130-SE
3G3RV-PFI3170-SE
3G3RV-PFI3200-SE
3G3RV-PFI3410-SE
3G3RV-PFI3600-SE
3G3RV-PFI3800-SE
EN 55011 class
B, 25 m
A, 100 m
B, 25 m
A, 100 m
B, 25 m
A, 100 m
B, 25 m
A, 100 m
B, 25 m
A, 100 m
B, 25 m
A, 100 m
A, 100 m
A, 100 m
A, 100 m
A, 100 m
A, 100 m
A, 100 m
A, 100 m
Current
(A)
Weight
(kg)
10
18
21
35
60
70
100
130
170
250
400
600
800
1.2
1.3
1.8
2.2
4.0
3.4
4.5
4.7
6.0
11
8.6
11.0
31.0
B
Monitor option cards
Type Model
AO-08 / 3G3IV-PAO08
AO-12 / 3G3IV-PAO12
Description Function
• Outputs analog signal for monitoring inverter output state (output freq., output current etc.) after absolute value conversion.
• Output resolution: 8 bits (1/256)
• Output voltage: 0 to {10 V (non isolated) EOutput channel: 2 channels
Analog monitor card
• Outputs analog signal for monitoring inverter output state (output freq., output current etc.)
• Output resolution: 11 bits (1/2048) + code
• Output voltage: |10 to {10 V (non isolated) EOutput channel: 2 channels
DO-08 / 3G3IV-PDO08
DO-02C / 3G3IV-PDO02C
Digital output card
2C-relay output card
• Outputs isolated type digital signal for monitoring inverter run state
(alarm signal, zero speed detection etc.) .
• Output channel: photo coupler 6 channels (48 V, 50 mA or less)
Relay contact output 2 channels (250 VAC, 1 A or less 30 VDC, 1 A or less)
• Two multi-function contact outputs (2C-relay) can be used other than those of the inverter proper unit.
264 Frequency inverters
Y203-EN2-02-Katalog.book Seite 265 Mittwoch, 24. Mai 2006 2:22 14
C
Feedback speed control cards
Type Model
PG-A2 / 3G3FV-PPGA2
Description Function
• Phase A pulse (single pulse) inputs (voltage, complementary, open collector input)
• PG frequency range: Approx. 30 kHz max.
[Power supply output for PG: +12 V, max. current 200 mA]
• Pulse monitor output: +12 V, 20 mA
PG-B2 / 3G3FV-PPGB2
PG-D2 / 3G3FV-PPGD2
• Phase A and B pulse inputs (exclusively for complementary input)
• PG frequency range: Approx. 30 kHz max.
[Power supply output for PG: +12 V, Max. current 200 mA]
• Pulse monitor output: Open collector, +24 V, Max. current 30 mA
PG speed controller card
(used for V/f control with PG or flux vector) • Phase A pulse (differential pulse) input for V/f control (RS-422 input)
• PG frequency range: Approx. 300 kHz max.
[Power supply output for PG: +5 V or +12 V, Max. current 200 mA]
• Pulse monitor output: RS-422
PG-X2 / 3G3FV-PPGX2 • Phase A, B and Z pulse (differential pulse) inputs (RS-422 input)
• PG frequency range: Approx. 300 kHz max.
[Power supply output for PG: +5 V or +12 V, Max. current 200 mA]
• Pulse monitor output: RS-422
D
Communication option cards
Type Model Description
1.
SI-N1
SI-P1
SI-S1
SI-J
SI-T
CM090
DeviceNet option card
PROFIBUS-DP option card
CANopen option card
LONWORKS option card
MECHATROLINK-II option board
Ethernet option card
Function
• Used for running or stopping the inverter, setting or referencing parameters, and monitoring output frequency, output current, or similar items through DeviceNet communication with the host controller.
• Used for running or stopping the inverter, setting or referencing parameters, and monitoring output frequency, output current, or similar items through PROFIBUS-DP communication with the host controller.
• Used for running or stopping the inverter, setting or referencing parameters, and monitoring output frequency, output current, or similar items through CANopen communication with the host controller.
• Used for HVAC control, running or stopping the inverter, setting or referencing parameters, and monitoring output current, watt-hours, or similar items through LONWORKS communications with peripheral devices.
• High speed motion bus
• Used for running or stopping the inverter, setting or referencing parameters, and monitoring output frequency, output current, or similar items through MECHATROLINK-II communication with the host controller.
• Host contoller: Trajexia, MCH and MP series
1
• Modbus TCP/IP ethernet interface unit
Please refer to Trajexia, MCH or MP series for host controllers detailed information.
E
Reference option cards
Type Model Description
AI-14U / 3G3IV-PAI14U
AI-14B / 3G3IV-PAI14B
Analog input card
Function
• 2 channel high resolution analog input card
• Channel 1: 0 to 10 V (20 K
Ω
)
• Channel 2: 4 to 20 mA (250
Ω
)
• Resolution 14 bit
• 3 Channel high resolution analog input card
• Signal level: -10 to +10 V (20 K
Ω
)
• 4 to 20 mA (250
Ω
)
•Resolution: 13 bit + sign
• 8 bit digital speed reference input card
• 16 bit digital speed reference input card
DI-08 / 3G3IV-PDI08
DI-16H2 / 3G3IV-PDI16H2
F
PLC option boards
Type Model
3G3RV-P10ST8-E
Digital reference card
Description
PLC option
Function
• Full PLC features, wireless installation and seamless access to the inverter parameters and analogue/digital inputs and outputs.
• Embedded Compubus/S fieldbus
• Standard OMRON tools can be used for programming
• Same features as standard models with DeviceNet support.
PLC option with DeviceNet
3G3RV-P10ST8-DRT-E
Varispeed G7 265
Y203-EN2-02-Katalog.book Seite 266 Mittwoch, 24. Mai 2006 2:22 14
G
Accessories
Type Model
JVOP-160-OY
Description
5 lines LCD digital operator
7 language support
Installation
Panel cutout
57
2-M3 MTG Holes
Panel
JVOP-161-OY
14.5
44
Through
Hole
70
7 segment LED digital operator
70 15.8
6.4
(60)
Panel cutout installation
3G3IV-PCN126
3G3IV-PCN326
3G3IV-PCN329-E
G
Accessories
Type Model
CX-drive 1.1
DriveWorksEZ
CX-One
Digital operator extension cable
1 meter
3 meters
PC configuration cable
Description
Computer software
Computer software
Computer software
-----
-----
Function
Configuration and monitoring software tool for drives (Version 1.1 or higher)
Programming special functionality software tool for drives
Complete automation software including CX-drive.
266 Frequency inverters
Y203-EN2-02-Katalog.book Seite 267 Mittwoch, 24. Mai 2006 2:22 14
H
Braking unit, braking resistor unit
Braking unit
Inverter
Inverter-mounted type
(3 %ED, 10 sec max)
2
Braking resistor unit
1
Separately-installed type (10 %ED, 10 sec. max.)
3
4015
4018
4022
4030
4037
4045
4055
4075
4090
4110
4132
4160
4185
4220
4300
2022
2030
2037
2045
2055
2075
2090
2110
40P4
40P7
41P5
42P2
43P7
44P0
45P5
47P5
4011
Model
CIMR-
G7C_
20P4
20P7
21P5
22P2
23P7
25P5
27P5
2011
2015
2018
Voltage
Max. applicable motor output kW
0.4
0.75
1.5
2.2
3.7
200 V class
22
30
37
45
55
5.5
7.5
11
15
18.5
1.5
2.2
3.7
4.0
5.5
7.5
11
75
90
110
0.4
0.75
400 V class
15
18.5
22
30
37
45
55
75
90
110
132
160
185
220
300
Model
CDBR_
2022B
2015B
2015B
2022B
2022B
2110B
2110B
2110B
4030B
4030B
4045B
4045B
4030B
4045B
4220B
4220B
4220B
4220B
4220B
4220B
4220B
No. of used
Model
ERF-150WJ_
Built-in
Built in
1
2
2
2
2
1
1
1
1
1
1
1
2
2
1
1
1
1
1
1
2
201
201
101
700
620
---
751
751
401
301
201
---
Resistance
No. of
Used
200
Ω
200
Ω
100
Ω
70
Ω
62
Ω
1
1
1
1
1
750
Ω
750
Ω
400
Ω
300
Ω
200
Ω
1
1
1
1
1
---
---
Braking torque %
220
125
125
120
100
230
130
125
115
110
Model
LKEB_
Specifications of resistor
No. of
Used
20P7
20P7
21P5
22P2
23P7
25P5
27P5
70 W 200
Ω
1
70 W 200
Ω
1
260 W 100
Ω
1
260 W
390 W
520 W
780 W
70
Ω
1
40
Ω
1
30
Ω
1
20
Ω
1
2011 2400 W 13.6 Ω 1
2015 3000 W 10
Ω
1
2015 3000 W 10
Ω
1
2022
2015
2015
2022
2022
2022
2022
4800 W
3000 W
3000 W
4800 W
4800 W
4800 W
4800 W
6.8
Ω
1
10
Ω
2
10 Ω 2
6.8
Ω
2
6.8
Ω
2
6.8
Ω
3
6.8
Ω
4
2018
40P7
4800 W 8 Ω 5
70 W 750
Ω
1
40P7 70 W 750
Ω
1
41P5
42P2
260 W 400
Ω
1
260 W 250
Ω
1
43P7 390 W 150
Ω
1
45P5
47P5
4011
520 W 100
Ω
1
780 W
1040 W
75
Ω
1
50
Ω
1
4015
4018
1560 W
4800 W
40
Ω
1
32
Ω
1
4022 4800 W 27.2
Ω
1
4030
4037
6000 W
9600 W
20
Ω
1
16
Ω
1
4045 9600 W 13.6 Ω 1
4030 6000 W 20
Ω
2
4045 9600 W 13.6
Ω
2
4030
4030
6000 W
6000 W
20
Ω
3
20
Ω
3
4045 9600 W 13.6
Ω
4
4045 9600 W 13.6
Ω
4
4045 9600 W 13.6
Ω
4
4037 9600 W 16
Ω
5
4045 9600 W 13.6
Ω
6
Braking torque %
220
125
125
120
125
115
125
125
125
125
125
125
100
120
100
110
120
100
230
130
125
135
135
135
130
135
125
125
125
125
125
125
135
145
100
100
140
140
120
110
110
1.6
1.6
1.6
96
96
64
64
6.4
9.6
9.6
6.4
6.4
Connectable min resistance value
Ω
48
48
48
16
16
16
9.6
9.6
9.6
9.6
32
1.
When connecting a mounting type resistor or braking resistor unit, set system constant L3-04 to 0 (stall prevention disabled during deceleration). If operating without changing the constant, motor does not stop at set deceleration time.
2.
When connecting mounting type braking resistor, set system constant L8-01 to 1 (braking resistor protection enabled).
3.
Load factor during deceleration to stop a load with constant torque. With constant output or continuous regenerative braking, the load factor is smaller than the specified value.
4. Resistance value per one braking unit. Select a resistance value that is larger than connectable minimum resistance value to obtain enough braking torque.
5.
For an application with large regenerative power such as hoisting, the braking torque or other items may exceed the capacity of a braking unit with a braking resistor in a standard combination (can result in capacity overload). Contact your OMRON representatives when the braking torque or any other item exceeds the values in the table.
32
32
20
20
19.2
19.2
19.2
12.8
12.8
19.2
12.8
3.2
3.2
3.2
3.2
3.2
3.2
3.2
Varispeed G7 267
Y203-EN2-02-Katalog.book Seite 268 Mittwoch, 24. Mai 2006 2:22 14
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
Cat. No. I37E-EN-01A In the interest of product improvement, specifications are subject to change without notice.
268 Frequency inverters
Изтегляне
Реклама