WDE1211001

DRUM WASHING MACHINE

Model : DWD-1211RT

DWD-1221RT

DWD-1223RT

JUL. 2005

DRUM WASHING MACHINE

SERVICE GUIDE

1. WHAT IS DRUM? .......................................................................................2

2. SPECIFICATION OF DRUM WASHING MACHINE ..................................6

3. VERIFICATION OF DRUM ASSY .............................................................7

4. PARTS LIST FOR EACH ASSY .................................................................8

5. SEQUENCE CHART OF PCB..................................................................20

6. SPECIFICATION OF ELECTRONIC PARTS ...........................................28

7. WIRING DIAGRAM ................................................................................. 47

8. TROUBLESHOOTING REGARDING DRAIN ..........................................49

9. INSTALLATION GUIDE ............................................................................50

10. ATTENTION POINT WITH SERVICE ....................................................52

1. WHAT IS DRUM ?

1. WHAT IS DRUM WASHER?

One of the famous washers in the globe which uses laundry falling energy.

2. Sales point of our washer

◈ The biggest capacity 12kg with compact size

◈ Envionmently friendly washer with NANO technology

• Sterilizing upto 99.9%

◈ No damage and entanglement but excellent washability

◈ 4way savings-noise, vibration, washing times, energy

◈ Self-cleaning course of Drum

◈ Good washing performance with heating system

◈ Condensing dry system with saving energy

◈ Sunshine dry effects with infrared x-ray

◈ Big door glass with easy laundry take-in/out

◈ The higest spin speed - 1200rpm

◈ No use of Drain pump ; good quality of drain and low noise

2

3. THE DRIVE SYSTEM OF DRUM WASHING MACHINE

DRAIN

MOTOR

WASH

TUB

DRUM

LIFTER

• DD CONTROL : DIRECT DRIVE TYPE

• BLDC MOTOR

BLDC

3

4. DRIVE SYSTEM

3. INLET PARTS

• COLD : 3-WAY

- COLD, PREWASH, DRY

• COLD : 2-WAY

- COLD, PREWASH

6. DRY PARTS

• HEATER DRY : 1200W

• BLOWER FAN

• FAN MOTOR : BLDC

• THERMISTOR

• THERMOSTAT

: FUSE, BI-METAL

• CONDENSING SYSTEM

• DRY FAN DRIVE

-> GENERATION OF

HEATER ’

-> TEMP. SENSOR

-> 95 ℃ OFF 87 ℃ ON

5. DOOR 부

• DOOR LOCK S/W

: WATER ADDING FUNCTION

• LOCK HINGE

• DOOR AS : GLASS

• GASKET

7. DRAIN

• DRAIN MOTOR

• VALVE HOUSING

4

4

8. SUPPORTER

• BASE

• DAMPER AS : 3(70N)

1. CONTROLLER

• MAIN PCB

• FRONT PCB

• HARNESS

• NOISE FILTER

• POWER CORD : 15A

2. DRIVE PARTS

• BLDC MOTOR

• DRUM

• BEARING

• SPIDER/SHAFT

• TUB

• WEIGHT BALANCER

4. WASH HEATING

• WASH HEATER : 1000W

• THERMISTOR

• 30 ℃ FIXED TEMP. CONTROL

• 50 ℃ ,60 ℃ BOIL

5. FUNCTION

3. INLET PARTS

• 3-WAY INLET VALVE

• 2-WAY INLET VALVE

• INLET BOX

1. CONTROLLER

• FRONT PCB

• NOISE FILTER

• MAIN PCB

5. DOOR AS

• GLASS

• HINGE

• DOOR LOCK S/W

• GASKET

8. SUPPORTER

• BASE

• DAMPER AS : 3(70N)

• SPRING : 4

7. DRAIN

• DRAIN MOTOR

• VALVE HOUSING

• HOSE

5

RAIN

RAIN MOTOR

ALVE HOUSING

OSE

5

6. DRY : DUCT AS

FAN MOTOR

FAN

HEATER DRY

BI-METAL S/W

TEMP. SENSOR

TEMP. FUSE

• LIFTER

• ROTOR

• STATOR

• SHAFT

• BEARING

BLDC MOTOR

DRIVE PARTS

• SPIDER

• DRUM

• TUB

• WEIGHT BALANCER

2. ROTATION

4. WASH HEATING

• WASH HEATER

• THERMISTOR

2. DRUM WASHING SPECIFICATION OF MACHINE

1. PANEL TYPE 1

DIMENSION(WxDxH)

MACHINE WEIGHT

WATER CONSUMPTION

WASHING CONSUMPTION

POWER SOURCE

POWER

CONSUMPTION

WASHING

DRY

WASHING

CAPACITY SPIN

DRY

WASHING TYPE

DRY TYPE

OPERATION WATER PRESSURE

630mm(W) x 755mm(D) x 950mm(H)

90 / 85 ㎏

WASH 155 ℓ / DRY 28 ℓ

45 ℓ

110V / 60Hz

1100W (Heating )

1250W

12 ㎏

12 ㎏

7.0

DRUM TYPE

Digital condensing dry system

29kPa ~ 784kPa(0.3

㎏ f/cm 2 ~8 ㎏ f/cm 2 )

12

13

14

15

8

9

10

11

6

7

4

5

NO

1

2

3

PARTS NAME

FRME DOOR O

DOOR WINDOW

DCD STICKER

PANEL LOWER

CABINET FRONT

PANEL LOWER

FRAME TOP F

FRAME TOP R

CABINET

PLATE TOP

CASE HANDLE

HANDLE CAP

BADGE

WINDOW DISPLAY

DECO. WINDOW

24

25

26

27

20

21

22

23

16 BUTTON DOOR UNLOCK

17 BUTTON FUNCTION

18

19

DECO. FUNCTION

PLATE DISPENSER

BUTTON POWER

BUTTON DIAL OUT

BUTTON DIAL IN

HANDLE CABINET

BASE UNDER

6

3. VERIFICATION OF DRUM ASSY

PLATE TOP ASS'Y : 7 EA

INLETBOX ASS'Y

PANEL F ASS'Y

PANEL 1 :20EA

PANEL 2: 17 EA

CABINET F ASS'Y : 19 EA

7

CABINET AS : 10 EA

DUCT B AS A + DUCT PIPE : 23 EA

7

BASE U AS : 8 EA TUB AS : 29 EA

4. PARTS LIST FOR EACH ASSY

1. THE EXPLODED VIEW OF INLET BOX ASSEMBLY

No.

PARTS NAME PARTS CODE DESCRIPTION

3612608300 ABS,

CASE HANDLE

SCREW TAPPING

3611139400 ABS,

3611139700

9121301208

ABS, DWD-E1221** / DWD-E1223**

T2S PAN 3X12 SUS

D03 CASE PP

D04 CAP 3610916600 PP

D05 INLETBOX 3617505310 FRPP

D06 NOZZLE AS 3618103510 NOZZLE TOP + UNDER

D07 PACKING 3614010000 EPDM

D08 HOSE INLET 3613266400 EPDM

D09 CLAMP AS 3611203200 SWC/SPC, ID=60

1

1

3613267000 EPDM,ID=10,OD=16,L=355mm

3613266600 EPDM,ID=10,OD=16,L=335mm

D12 CLAMP 3611203800 ID=15.5

VALVE INLET

3615415900 DR12AS, 100~130V, 95mA,5W(wash+ dry)

3615415800 DR12AS, 100~130V, 95mA,5W(wash only)

UNITS

1

1

1

1

2

1

REMARK

HANDLE CAP OF FIXED

1

INLETBOX/TUB R

2

1

1

PRE WASH

WASHING

4

1

1

COLD, 3-WAY

COLD, 2-WAY

8

2. THE EXPLODED VIEW OF PANEL F ASSEMBLY( TYPE 1, DWD-1211**)

No.

B01

B02

B03

B04

B05

B06

B07

PARTS NAME

PANEL F

HOLDER COURSE OUT

HOLDER COURSE IN

DECORATOR POWER

BUTTON POWER IN

BUTTON POWER OUT

BUTTON DOOR LOCK

B09

B16

B17

B18

B19

B10

B11

B12

B13

B14

B15

BUTTON FUNCTION

SCREW TAPPING

WINDOW DISPLAY

DECORATOR WINDOW

HOLDER POWER

HOLDER COURSE MAIN

BUTTON DIAL MIDDLE

BUTTON DIAL OUT

BUTTON DIAL IN

CUSTOM LED

CASE PCB F

PCB FRONT AS

PCB FRONT AS

SCREW TAPPING

PARTS CODE

3614282200

3613049000

3613048900

3611631000

3616602800

3616602900

3616602600

361163900

3616602700

7121301208

3615502700

3611630800

3613048800

3613049100

3616602400

3616602500

3616602300

3613014400

3611139600

PRPSSW1D13

PRPSSW1D14

7122401411

ABS

DESCRIPTION

ABS

ABS

ABS

ABS

ABS

ABS

ABS

ABS

T2S PAN 3X12 SUS

ABS

ABS

ABS

ABS

ABS

ABS

ABS

ABS

HIPS

DWD-E1211RT

DWD-E1211WT

T2S TRS 4X14 MFZN

9

1

3

2

1

1

1

1

1

UNITS

1

1

1

1

1

1

1

1

1

7

1

1

1

1

REMARK

2. THE EXPLODED VIEW OF PANEL F ASSEMBLY(TYPE 2, DWD-1221** / DWD-

No.

PARTS NAME

B02 WINDOW LED COURSE

B04 DECOATOR BUTTON POWER

B06 BUTTON DOOR OPEN

SCREW TAPPING

B08 HOLDER LED COURSE

B09 HOLDER LED CUSTOM

B10 CASE PCB F 3611139600

SCREW TAPPING

B11 PCB

B12 BUTTON DIAL OUT

B13 BUTTON DIAL IN

PARTS CODE

3614282300

3615502900

3613049400

3611631100

3616603100

361603200

3616603000

7121301208

3613049300

3613049200

HIPS

7122401411

PRPSSW2D10

3616603400

3616603300

3615502800

3611139700

DESCRIPTION

ABS(BK-8410AT)

ABS 1

ABS 1

T2S PAN 3X12 SUS

ABS 1

1

ABS 1

T2S TRS 4X14 MFZN

DWD-E1221RT

ABS 1

ABS 1

ABS(BK-8410AT)

UNITS

1

REMARK

3

7

1

1

10

3. THE EXPLODED VIEW OF CABINET F ASSEMBLY

11

No.

C02 PLATE HINGE SUPPORT

C03 HINGE DOOR 3612902700

C04 CAP HINGE DOOR

C05 SPECIAL BOLT

C06 SPRING DOOR

C07 CLAMP DOOR

C08 FRAME DOOR I.

C14

C17

C18

C20

PARTS NAME

FRAME DOOR O.

FRAME DOOR O.

PIN HANDLE 3618200100

HOOK DOOR 3613100700

SWITCH DOOR LROCK

PARTS CODE DESCRIPTION

3610811000

3614531500

Zn-DC Zn Coating 1

SGCC(GI), 1.6t 1

3610916500

3616030700

POM

FLANGE HEAD, 5X10

3615113800

3611204200

3612204700

3615202300

7115401608

3606001310

GLASS

3618304200

3612204600

HSW3, D=1.0, N=7

HSW3, D=1.4, L=1245mm

TB53(Heat-Resistance PP)

4X20

1

ABS,CR COATING,

3612204610

3611425600

3615113700

SUS, D=3.0, L=39 1

Zn-DC Zn Coating 1

ABS,UV SPRAY

3612608200

3619046410

ABS

DF'S 125V 16A PTC-SOLENOID

UNITS

1

REMARK

4

3

1

1

1

3

3

12

1

1

1

1

1

1

12

4. THE EXPLODED VIEW OF BASE U ASSEMBLY

No.

G02

G04

PARTS NAME

PCB AS

PCB AS

PCB AS

LINE FILTER AS

TRANS SMPS (DWD)

G07 FOOT

SPECIAL BOLT

PARTS CODE DESCRIPTION

PRPSSW1D03 DWD-E1211RT

PRPSSW1D04

PRPSSW2D03

PRPSSW2D04

3611908000

DWD-E1211WT

DWD-E1221RT, DWD-E1223RT

DWD-E1221WT, DWD-E1223WT

EMI

3610391900 PP

5EM1028010 T2S-V24,600uH(1~3)

3615303600 PO+Coating,

ABS

3612100600 BUTYL

4

3616029000 10 X 1.25, 51MM

13

1

1

4

UNITS

1

1

1

1

1

REMARK

4

4

5. THE EXPLODED VIEW OF TUB ASSEMBLY

14

No. PARTS NAME

H01 BALANCER WEIGHT AS (R)

H05 GASKET

H06 CLAMP GASKET AS

H07 SPRING SUSPENSION F

H08 TUB FRONT

H16

H17

H18

H25

H28

VALVE DRAIN AS

AIR TRAP AS 3610AAR100

SPRING SUSPENSION R

UNIT BUBBLE PUMP

H26 BASE

H27 UNIT MOTOR BLDC

UNIT ROTOR BLDC

PARTS CODE

3616106200

3614404900

3611204300

EPDM

3612320700

6.5KG

PP

MFZN

EPDM

DESCRIPTION

1

3611203600

3615113500

3618820400

3612006700

361A700200

361A700100

3617003300

361A400300

361A300200

36196TAK00

3615415100

WIRE

YELLOW

PP+GF, FH7303GM

SUS

PP

AKS(TURKEY)

SUS

AL+S45C

ASSY

1

3615113600

3612321100

EPDM

3616303100

3616303000

3616303200

BLACK

6506

AL

6205

1

3613266300

36189L4G00

EPDM

AC 100~130V,DBK-115DA

3610392000

36189L4000 WS2A28G001,310VDC

MAGNET24,SERRATION 36189L4900

3612801100 110V 1KW 12.1

Ω 6.1W/SQ SUS RW8TF 144 ℃

15

UNITS REMARK

2

1

1

2

1

1

1

1

1

1

1

1

1

1

1

3

3

1

1

1

1

1

1

1

2

6. THE EXPLODED VIEW OF DUCT B AS A + DUCT PIPE ASSEMBLY ( WASH +

16

No.

E01

E03

E06

E07

E08

E09

PARTS NAME

UNIT FAN MOTOR

DUCT B UPPER AS

SCREW TAPPING

SPECIAL WASHER

FUSE TEMPERATURE

FRAME HEATER FRANGE

PARTS CODE DESCRIPTION

36189L3Z00 ISM-77806DWWA 24V CW 8P 14W

AL 1

361A200600

3611203310

3611885700

AL, SUNSHINE DRY

DALE-3

7122400811

3616030300

361A800120

3612204100

ø 133x45L IMPELLER

T2S TRS 4x8

T1.0 OD=20 ID=4.3

128 ℃ (DF128S) 250V 15A

SBHG 1.0t

E10 DUCT B LOWER 361A200100 AL

3614009900 SILICON

3619046500 ON ℃ OFF 150 ℃ 230V 15A

DRY Ω 6.1W/SQ INCOLOY800 RL89 1

361AAAAC00 CWT-DEW-1C03

E17

E18

E21

GASKET SEAL A

GASKET SEAL B

DUCT PIPE AS

3614009800

3611562800

3612320800

3612320810

3612320900

SILICON

NBR

EPDM FOAM

EPDM FOAM

Asbestos

AL

361A200700 11KG

3611203700 DUCT

3616403000 EPDM

1

UNITS REMARK

1

1

1

1

1

1

4

1

1

1

1

1

1

1

1

2

1

1

1

1

17

7. THE EXPLODED VIEW OF CABINET ASSEMBLY

No.

F02

F03

PARTS NAME

FRAME TOP R

FRAME TOP L

F04 CABINET

F05 COVER BACK

PARTS CODE

3618103200 PP

3612204300

3612204900

GI, 1.6T

GI, 1.6T

DESCRIPTION

3610810900 SGCC,0.8T,PAINTING

3611425500 0.4T, SGCC

3615202200 POM

F10 FRAME LOWER

F11 SENSOR PRESSURE

F12 CORD POWER AS

3612608100 PP

3612204200 SBHG, 1.2T

3614825200

3611339810

5V DRUM,DL-DW01

VCTFK 2C 15A 125V

18

1

1

1

4

1

4

1

1

1

UNITS REMARK

1

1

1

8. THE EXPLODED VIEW OF PLATE TOP ASSEMBLY

No. PARTS NAME

A01 FRAME PLATE F

A02 FRAME PLATE R

A03 PLATE 3614531600

A05 FIXTURE PLATE T

SCREW TAPPING

PARTS CODE

3612204400

3612204500

3614110500

3612007100

3613553800

7122401411

DESCRIPTION

ABS

ABS

SPONGE

1

STAPLE

ART+OPP

T2S TRS 4X14 MFZN

UNITS REMARK

1

1

1

2

1

12

19

5. SEQUENCE CHART OF PCB

1. SEQUENCE CHART

Cotton

( 標 準 )

Syntheti c

Heavy

Stain

Proces Time

少 低 低 低

Pre.

Wash

預 洗 n g h i

W a s

R i n s e

S p i n

Sensing

Water Supply

Pre. Wash

Drain

Balancing Spin

Mid.Spin

Sensing

Water Supply

Washing1

(Heating)

Washing 2

Drain

Balancing Spin

Mid.Spin

Water Supply

Rinse 1

Drain

Balancing Spin

Mid.Spin

Water Supply

Rinse 2

Drain

Balancing Spin

Mid.Spin

Water Supply

Rinse 3

Drain

Balancing Spin

Main Spin

20sec

2min

10min

8min

1min

1min

3min

20sec

2min

95min

85min

45min

35min

30min

25min

20min

15min

1min

1min

3min

2min

3min

1min

1min

3min

2min

3min

1min

1min

3min

2min

3min

1min

1min

7min

5min

3min

27min

End

Cloths Release

END

Wrinkles Protect

NOTE

Over Time Indication

60sec

10sec

30min

1:32

1:37

1:34

1:59

1.Heavy Stain Course: Pre.Wash is Basic Default.

Whites

( 高 溫洗 衣 )

少 低

ECO( 省 電 )

少 低

60min

2:27 2:37 1:47 2:02

20

Proces Time

Wool

毛 衣

Delicate

高 級衣

Blanket Quick30

快 洗

Drain

槽 淨 n g h i

W a s

R i n s e

Soak

Water Supply

"Wash 1

(Heating)"

Wash 2

Drain

Balancing Spin

Mid.Spin

Water Supply

Rinse 1

Drain

Balancing Spin

Mid.Spin

Water Supply

Rinse 2

Drain

Balancing Spin

Mid.Spin

Water Supply

Rinse 3

Drain

Balancing Spin

30min

2min

60min

50min

35min

30min

12min

25min

15min

7min

1min

1min

3min

2min

3min

2min

3min

1min

1min

7min

3min

1min

1min

3min

2min

3min

1min

1min

10min

S p i n

D

R

Y

Mid.Spin

포풀림

Dry

Wrinkles Protect

Cloths Release

End

END

Over Time Indication

NOTE

Cooling

END

5min

3min

60sec

40min

18min

5min

10sec

30min

60sec

10sec ■

46

46

1:07

1:15

1:48

1. Quick30( 快洗 )/Drain( 槽洗淨 ) - Dry is Basic Default

2. 防皺行程 (wrinkle protect): 完成所有行程後,沒有取衣時才會進入防皺行程 .

3. Memory : 已經設定 _ 標準,使用者可調整 .

Memory

記 憶

21

2. Main function of PCB program

2-1. LOAD SENSING

1) Deciding the water level

① Cotton, Whites, ECO course will be followed by this process.

② Check the water level with dry laundry at the starting wash.

③ Check the water level by using motor output data during 20 sec, 65 rpm.

2) Balancer Spin

① Check after finishing washing step with wet laundry.

② Checking by using motor output data during 20 sec, 65 rpm.

③ The decided data is different depending on loading condition.

2-2. BALANCE SPIN

1) Motor running during balance spin.

① Spreading the laundry : Rotating the same 45 rpm with left and right direction alternatively.

② Attaching stop : Attaching the laundry to drum inside with constant speed.

Unbalance checking point : First step, check the U.B at 95 rpm, 160 rpm.

Second step, check the U.B at 95 rpm, 350 rpm.

Third step, at 300 rpm. if the unbalance data is over the criterion,

This process will be repeated.

④ Drain step : Drain at water around 160 rpm.

⑤ After drain, check the unbalance data again. This is so-called balance spin step.

2) Property of balance spin.

① Conducting 10 times maximum.

② If the washer can not pass balance spin step during 10 times, then water will be supplied.

③ If the washer can not pass 20 times of balance spin, UE error mode will be displayed on PCB.

22

2-3. DOOR S/W

1) The working principle of Door S/W

① Door Locking

Bimetal on ( 3 sec) --> solenoid (supply 20msec pulse 2 times)

② Door Unlocking

Bimetal off --> solenoid (supply 20msec pulse, until unlock)

③ After door locking, all parts can work normally.

④ After pressing power button, if the temperature of wash thermistor is over 50 ℃ or the water level is over the safety level, the door will be locked.

⑥ The door the will be unlocked immediately after all processes are finished.

⑦ The door can be opened during processing if there is no problem to unlock.

23

2) DOOR OPEN SYSTEM

① If add the laundry during washing, press the door unlock button.

② Door open sequence at abnormal condition.

start / hold door unlock button, 2sec.ON

water level is less than safety level?

YES

Temperature is less than 50 ℃ ?

YES

Display <LOCK> off

NO

NO drain fan motor on/ cold water supply

Door open

24

2-4. Child Lock

① Press the TEMP ” DRY button simultaneously during processing.

② Under the Child Lock function, only power button is working.

③ During Child Lock function, CHL will be displayed on PCB.

④ In orden to unlock Child Lock mode, press "TEMP" and "DRY" simultaneously.

2-5. The sequence of drain

① If the checking time to reset point is below 1 min, the remaining drain time is 30 sec.

② If the checking time to reset point is over 1 min, the remaining drain time is 2 min.

③ If the checking time to reset point is over 10 min, OE singal will be appeared on PCB.

④ If the temperature is over 50 ℃ , the water will be supplied to high water level, then the drain will start.

25

3. Convenience service functions(test mode)

1. Testing Mode

PCB and other electronic parts will be tested without water supply whether they are normal or not.

1) Process : press power button --> press "SPIN" button 3 times with pressing "WASH" button --> 'L d' will be shown on LED --

> Whenever pressing "TEMP" button 1 time, below process will be occurred.

L C (Lock Closed) --> F ( Fan Motor) ---> H (Hot V/V) --> C (Cold V/V) ->

P (prewashing V/V) -> d ( dry V/V) -> bb (bubble) -> dr (drain motor) ->

L O(Lock S/W Open)

2) More details

① When turn on 'LOCK' singal, all process is conducting normaly.

② When working starts, the PCB displys all the sensor conditions.

③ In this case, BLDC Motor is not tested. In order to test it, select spin or rinse.

2. Continous testing mode

1) Process : after pressing "WASH", "RINSE", "SPIN" button simultaniously, press "POWER" button.

ALL LED On/Off 1 time --> L C (Lock Closed) ---> R (Motor right) --> L (Motor Left) --> F ( Fan Motor) ---> H

(Hot V/V) --> C (Cold V/V) --> b (pre-wash V/V)

--> d ( dry V/V) --> bb (bubble) --> h1 (HEATER WASH)--> h2(HEATER DRY) --> dr (DRAIN MOTOR On) --

>L O(Lock S/W Open)

2) More tails

① LED test can be done with all LED On.

② All sensor conditions will be shown on PCB during processing.

26

4. ERROR DISPLAY

ERROR

SINGAL

IE

OE

UE

LE

E2

E3

E9

E5

E6

E7

E8

H1

H2

H3

H4

H6

H7

H8

ERROR CAUSE COUNTERPLAN

WATER

INLET ERROR

DRAIN

ERROR

① inlet valve broken

② drain motor working during water supply

③ pressure switch disorderChange the Sensor Pressure

④ PCB can not check water level

① drain motor out of order

② inlet valve working during drain

③ pressure switch disorderChange the Sensor Pressure

④ PCB can not check water level

UNBALANCE ERROR ① laundry unbalance

DOOR

① door opened during processing

② LOCK S/W broken

OPEN ERROR

③ PCB can not check door lockChange the PCB

① continuous water supplyChange the Inlet-Valve

Overflow

FAN MOTOR disorder

② drain motor can not workChange the Drain Motor

③ pressure switch disorderChange the Sensor Pressure

① fan motor cannot work

② PCB cannot control fan motor

SENSOR PRESSURE

ERROR

① abnormal water level

Change the Inlet-Valve

Change the Drain Motor

Change the PCB

Change the Drain Motor

Change the Inlet-Valve

Change the PCB rearrange the laundry

Clode the Door

Change the LOCK SW

Change the Fan-Motor

The contact of the Connector or Change the PCB

Change the Sensor Pressure

HIGH VOLTAGE

ERROR

EMG ERROR

Direction Error motor disorder sensor temp. dry disorder

① huge noise

② spining with jamming clothes between gasket

③ PCB broken

① huge noise

② spining with jamming clothes between gasket re-installation rearrange the laundry

Change the PCB re-installation rearrange the laundry

③ motor broken

④ PCB broken

① move opposite direction

② motor Hall IC broken

Change the Motor

Change the PCB check the connector and change

① connector problem The contact of the Connector

② abnormal loading conditioncheck the loading condition and change

① sensor temp broken

② connector problem

Change the Sensor Temp.

The contact of the Connector sensor temp.

wash disorder overheating dry heater

① sensor temp. of washing broken

② connector problem

① fan motor cannot spin

② sensor temp. of dry brokenChange the Sensor Temp.

overheating wash heater

① heater working with no water supply

② sensor temp. of wash brokenChange the Sensor Temp.

abnormal of washing heater ① washing heater cannot workChange the Heater Wash abnormal of drying heater ① dry heater cannot work

Change the Sensor Temp.

The contact of the Connector

Change the Fan Motor check water level

Change the Heater Dry abnormal of sensor temp. of washing

① heater working with no water supply check the water level and washing heater

27

6. SPECIFICATION OF ELECTRONIC PART

NO PART NAME

1 VALVE INLET (2-Way)

Rating (V/Hz)

Model

WASH+DRY WASH

PART CODE

110-130/50-60 ◎ 3615415800

BOM DESCRIPTION

100-130 2WAY PP/BRACKET

2 VALVE INLET (3-Way) 110-130/50-60

3 SENSOR PRESSURE

4 CORD POWER AS

5V

Taiwan:

3611339800

3615415900 100-130 3WAY PP/BRACKET

◎ 3614825200

5V DRUM, DL-DW01

5V DRUM, DN-DD01

◎ ◎ 3611339810 VCTFK 2C 15A 125V

5 UNIT BUBBLE PUMP

6 HARNESS AS

7 HARNSS EARTH

100-130/50-60

DWD-E1211RT

DWD-E1211WT

110 A11

8 FUSE TEMPERATURE 15A 250V

9 SWITCH DOOR LOCK 100-130/50-60

-

◎ 36189L4G00 100-130 DBK-115DA RP-CUSH

-

3612793210 DRUM DRY-WASH-PO-NON HOT

3612793310 DRUM WASH ONLY-PO-NON-HOT

◎ 3612793400 GN/YW AWG18 FERRITE

361A800100 128 ℃ DF 128s 15A 250V

◎ ◎ 3619046410 DF ’

10 HWATER WASH

11 HEATER DRY

110/50-60

110/50-60

12 SWITCH THERMOSTAT 100-250V

UNIT MOTOR BLDC

13 UNIT STATOR BLDC

UNIT ROTOR BLDC

A11

14 THERMISTOR WASH

15 NTC THERMISTOR

16 UNIT FAN MOTOR

17 FAN AS

A11

Dry

Dry

Dry

18 DRAIN MOTOR

19 DAMPER FRICTION

20 DAMPER PIN

100-130/50-60

11kg A11

11kg A11

◎ ◎ 3612801100 110V 1KW 12.1

Ω 4.3W/SQ SUS 1R1A03305 144 ℃ IR1A033005

3612801300 110V 1.2KW 23.0

Ω 6.1W/SQ INCOLOY800 1R1A034001

3619046500 ON 120 ℃ OFF 150 ℃ 230V 15A VDE

36189L4000 3254D02000, 3114D02000, 310V, 250W

36189L4800 Φ 265X28H, 36SLOT, 25NESOR, 3254D02000 ◎

36189L4900 MAGNET24, SERRATION, 3114D02000

◎ 361AAAAB00 R25=11, 981 ㏀ , R80=1, 704 ㏀

361AAAAC00 R40=26, 065 ㏀ , R90=4, 4278 ㏀

36189L3Z00 ISM-77806DWWA 24V CW 8P 14W

3611885700 Φ 133x45L IMPELLER

◎ 36196TAK00 SV-HJ7T20D 100-110V ST23(56.5)

◎ 361A700100 70N AKS ST=170-245 DL=197.5

◎ 361A700200 AKS D=14.5

IR1A034005

NT-103NA

3254D02000,

3114D02000

CWT-DEW-1C03-0

CWT-DEW-1C02-0

ISM-77806DWWA

-

SV-HJ7T20D

-

-

TYPE

DR12AS

DR12AS

DL-DW01

DN-DD01

LP-70

DBK-115DA

-

-

-

DF128s

DF

28

1

TYPE

Material / Certi

Material Certi OPTION

Specification

SPEC

DR12AS

DR12AS

DL-DW01

DN-DD01

LP-70

DBK-115DA

-

-

-

DF128s

DF

IR1A033005

PP

PP

HIPS

-

-

-

PVC

-

-

PA66

SUS321

IR1A034005 INCOLOY800

X

X

X

BSMI R31050

X

X

X

X

VDE

IMQ CA02. 01619

VDE 72709

VDE 62726

VDE 119277

PRE-COLD,

SUS FILTER

PRE-COLD-DRY

SUS FILTER

3P-PCB,

BRACKET

Comply with PLUG-15A, 125V, CABLE:2. 0SQ VCTFK 2C

CNS3199, CNS10917 CABLE MARKING : R31050 VCTFK 300V 2C 2.00

- 2, CNS690

HOSE, CUSHION xxxx --LINETEK-- LF ”

HOSE Φ 4 L830(BL), UL1015AWG22 L230, MG621164(WH)

KET 1806 DL CONN UL1015 AWG18:HEATER, UL1015 AWG22:AC LOAD, UL1007 AWG22:DC LOAD

KET 1806 DL CONN UL1015 AWG18:HEATER, UL1015 AWG22:AC LOAD, UL1007 AWG22:DC LOAD

THERMAL

FUSE, BRACKET

-

-

-

BI-METAL, SOLEN0ID

BRACKET

RING TERM, ST710489-3x2-ST710946-3

UL1015 AWG18(AWG16) GREEN/YELLOW

FUSE 128 ℃ DF128S 15A/250V, TUBE SRGT(IDΦ 5)WH,

L/W UL1015 AWG18 105 ℃ 600V

PA66 25% GF V0, ,ICOW S/W(BI-M) 16A 125V,

SOLENOID 125V 130 Ω , PTC HEATER

THERMAL FUSE 167 ℃ , TUBE AISI321(SUS321),

Mg0 INSULATION, SEALANT EPOXY 120 ℃

TUBE INCOLOY800, INSULATION Mg0, GASKET SILICONE,

INSULATING BUSHING CERAMIC, SEALANT FPOXY 120 ℃

NT-103NA(5XV) F150-120, ± 5 ℃ NT-103NA

3254D02000,

3114D02000

CWT-DEW-1C03-0

CWT-DEW-1C02-0

ISM-77806DWWA

-

SV-HJ7T20D

-

-

MP

AS

STATOR

ROTOR

SUS

SUS

-

ALDC

-

-

X

X

X

X

X

X

OUTER ROTOR

-

SIDE SPONGE

-

-

-

B25/100=3760K

B25/85=3992K

±

±

2%

2%, L/W UL1007 AWG24 L=120, MG621164(KET)

DAMPER(70N)+PIN

28

1. VALVE INLET

1) CLASS

DIVI

SION

3-WAY

VALVE

2-WAY

VALVE

PARTS BODY

NAME COLOR SPEC

USE

COIL resistance

FLUX(100~240V 기준 )

0.2kgf

㎠ 1.0kgf

㎠ 3.0kgf

㎠ 5.0kgf

㎠ 8.0kgf

PRE-WASH

VALVE

4320~5280 Ω 2~5 ℓ 7~12 ℓ 8~13 ℓ 8~13 ℓ 8~13 ℓ

3615415000 IVORY PP MAIN

4320~5280 Ω 2~5 ℓ 7~12 ℓ 8~13 ℓ 8~13 ℓ 8~13 ℓ

VALVE

3615414900 BLUE PP

DRY VALVE 4320~5280 Ω

PRE-WASH

0.2~1.2

4320~5280 Ω 2~5 ℓ 7~12 ℓ 8~13 ℓ 8~13 ℓ 8~13 ℓ

VALVE

MAIN WASH

4320~5280 Ω 2~5 ℓ 7~12 ℓ 8~13 ℓ 8~13 ℓ 8~13 ℓ

VALVE

29

2) TROUBLE SHOOTING

TROUBLE

WATER IS

SUPPLIED

SITUATION

NO WATER

SUPPLY WITH

"WING" SOUND

CAUSE closed water tap coil short alien materal jammed alien material inside inlet valve unfixing connector

CHECK POINT check the water tap opened check the resistance 4320~5280 Ω check the filter

-

NO WATER

SUPPLY

WITH SILENCE check the connector coil short

WATER

SUPPLY

IS NOT

STOPPED

Etc

THE WATER

SUPPLY START

WHEN POWER

"ON"

THE WATER

SUPPLY START

WHEN POWER

"OFF" water leakage to the side harness short pressure s/w broken pressure hose broken inlet valve broken inlet valve poorly assembled

Checking method of coil resistance, harness, connector.

check the resistance 4320~5280 Ω check the connector check the pressure switch check the hose torn or twisted

check the leakage of inlet valve

MAIN PCB "8P" WHITE

CONNECTOR

SOLUTION

Open the water tap

PCB

ERROR MODE

"IE"

"IE"

"IE" Clean the filter

Change the Inlet-

Valve

The contact of the

Connector

Change the Inlet-

Valve

"IE"

"IE"

"IE"

"IE"

Change the Sensor

Pressure

Change the bad parts

Change the Inlet-

Valve

"E2"

"E2"

-

Change the Inlet-

Valve

WASH VALVE(GREEN) :

COMMON(BLUE)/RESISTANCE TEST

PRE-WASH VALVE(RED) :

COMMON(BLUE)/RESISTANCE TEST

DRY VALVE(YELLOW) :

COMMON(BLUE)/RESISTANCE TEST

COMMON(BLUE)

-

* "IE" ERROR : lack of water supply

30

2. PRESSURE SWITCH

TROUBLE SITUATION continuously inlet valve is normal, water supply but continuous water supply

CAUSE bellows problem

CHECK POINT frequency Check : refer to below hose problem

"E9"

ERROR water level frequence below 15kHz or over

30kHz clogged hose connector slipped out pressure switch broken connector short

Checking method of coil registance, harness, connector.

frequency Check : refer to below check the fine hole check the hose condition check the connector condition frequency Check : refer to below connector broken

SOLUTION

PCB

ERROR MODE

"E2" change the pressure switch change the hose change the hose remove the alien reconnecting change the pressure switch

"E2"

"E2"

"E2"

"E9"

"E9"

"E9"

GROUND(GRAY)

INPUT SIGNAL(WHITE)

OUPUT SIGNAL

(PINK)

"12P" WHITE CONNECTOR

* E2 : overflow error ;Water level is higher than overflow level because of continuous water supply.

E9 : Pressure switch trouble, the frequency is less than 15kHz or more than 30kHz in the processing.

31

3. DOOR LOCK SWITCH

1) CLASS

Failure

Status

Tick Sound

"LE" Error

Details

Tick Sound happens

"LE" with tick sound

"LE" without tick sound

Cause

Normal Sound

Connector slipped out

DOOR closed loosely

Failure of DOOR HOOK

CATCH CAM broken

Connector slipped out

Diagnosis of Failure Solution

When Door is locked/unlocked, this Solenoid Working sound is heard.

check the joining status of Assemble Connector

-

connector by eye

Tick sound happen check the joining status of connector by eye

Close Door securely

Replace DOOR AS

Replace DOOR S/W

Assemble Connector

PCB

ERROR MODE

-

"LE"

"LE"

"LE"

"LE"

"LE"

Terminal slipped out Refer to below checking method.

Refer to below checking

Insert Receptacle no.2

or no.3

Replace DOOR S/W

"LE"

Solenoid Coil

Disconnection method.

"LE"

During operation, "Power Failure" or "Forced Power S/W OFF" causes door not to be opened until maximum 5 minutes pass.

DOOR not open

Power Failure/Forced

Power Off during operation

Power on state Water remained in tub Check whether the water level is over safety level.

After draining water, open the door

-

ETC hot temp. in tub

Follow below process

Prevent the burn due to hot temp. after dry.

Checking Method of wiring/coil disconnection, connector slipping out on PCB board : Operate with the Door lock switch connected

1. Replacing method of DOOR LOCK SWITCH

1) Open DOOR, disassemble CLAMP SPRING for fixing gasket

2) Disassemble GASKET

3) Disassemble two screws 5 for DOOR LOCK S/W

4) Disassemble DOOR LOCK S/W

5) Assemble in the reverse order

32

2. Checking method of DOOR LOCK SWITCH

PIN

array

2 3 4 5

(No no.1)

3. Checking method of DOOR LOCK SWITCH

Between Viloet and Blue wire

: If 156 ~ 234 Ω , it is normal

Between No. 3 & No.4

: if 156 ~ 234 Ω , it is normal

33

4. HEATER

1) SPEC. OF HEATER

Part Name

Maker

Power source

Power Consumption

Resistance

Current Density

Temperature fuse

Thermistator

Material

Part Code heater wash

IRCA

110V

1000W ± 5%

12.1

4.3

144 ℃

Combined in heater

SUS430

361280110

1. Temperature fuse

• If the heater is on without water, because of pressure switch trouble, fire can be occurred.

Temperature fuse prevents this hazard of fire.

• The heater wash must be submerged in water.

heater dry

IRCA

110V

1200W ± 5%

10.08

3.5

128 ℃ (exterior) exterior

INCLOY800

3612801300

2. The device for overheating prevention of the dry heater

• Temperature fuse : 128 ℃ cut-off type, 250V 15A

• Thermostat : 150 ℃ off 120 ℃ on,230V 15A

34

2) DIAGNOSIS OF THE FAILURE

Failure

Status

Can not heat water

Cause Diagnosis of Failure Solution

PCB

Error Mode

"H6"

Overheat water

Can not dry

Wiring Disconnectiona

Heater Wash

Disconnection

Connector/Terminal

Seclusion

Heater Wash/Thermistor

Wash Poor

Heater Wash/Thermistor

Wash Poor

Wiring Disconnection

Check whether disconnected or not : See Fig. A

Check whether disconnected or not : if normal, the resistance between two ends is 23.3~25.7

Ω .

Check whether disconnected or not : See Fig. A

Measure the resistance of two ends of the sensor : refer to the attached temp./resistance table

Measure the resistance of two ends of the sensor : refer to the attached temp./resistance table

Check whether disconnected or not : See Fig. B

Connecting the disconnecting point

Replacing Heater Wash

Inserting terminal/connector tightly

Replacing temp. sensor

Replacing temp. sensor

Connecting the disconnecting point

Replacing Heater Wash

Replacing Fuse Temp.

"H2"

"H6"

"H6"

"H2"

또는

"H7"

"H4"

Heater Dry Disconnection

Fuse Temp.

Check whether disconnected or not : if normal, the resistance between two ends is 22.3~24.7

Ω .

Shipped out Check the connection of two ends of fuse temp.

Check whether disconnected or not : See Fig. B

Inserting terminal/connector tightly

Replacing Fan Motor

"H7"

"H7"

Connector/Terminal

Slipped out

Operation Trouble of FAN

MOTOR Excessive Noise : Restraint/Failure of Fan Motor

Reassembling the Fan

Replacing temp. sensor

Heater Wash/Thermistor

Wash Failure

Fan slipped out : MOTOR is operating, but there is rotating sound.

Measure the resistance of two ends of the sensor : refer to the attached temp./resistance table

Checking Method of wiring/coil disconnection, connector slipping out on PCB board : Operate with the heater connected

"H7"

"H7" 또는 "E3"

"H7"

"H1"

[Figure A] * Inspect Wiring/Heater

Wash Disconnection :

Check the current and resistance of two terminals

[Figure B]

3P Connector orange wire

1P Connector

Blue Wire

* Inspect

Wiring/Heater Dry

Disconnection :

Check the current and resistance of two terminals

3P Connector

Red Wire

1P Connecor

Blue Wire

35

* Replaceing method of Heater and Temp. Sensor

1. Disassemble Connector

2. Disassemble EARTH and NUT for fixing heater

3. Replace heater & sensor

4. Assemble in the reverse order. Be sure to assemble in the order : Nut for heater-Nut for EARTH.

* Structure of DUCT B As

1. Heater Dry

2. Diecasting DUCT

3. Thermistor Dry

4. FAN MOTOR

5. Fuse Temp.

6. Switch Bimetal

7. FAN

* ERROR MODE

1. "H1" : Thermistor Dry OPEN/SHORT

2. "H2" : Thermister Wash OPEN/SHORT

3. "H3" : Dry Overheating(Sensing Temp. is over 125 ℃ )

4. "H4" : Wash Overheating(Sensing Temp. is over 95 ℃ )

5. "H5" : Wash Overheating

(In Wool, Lingerie courses sensing temp. is over 45 ℃ )

6. "H6" : Abnormal condition of Heater Wash

(when the temp. increase at 10 minutes after heater operation is under 10

℃ )

7. "H7" : Abnormal condition of Heater Dry(when the temp. increase at 10 minutes after heater operation is under 10 ℃ )

8. "H8" : Heater Wash Overheating

(when the temp. increase within 30sec after heater operation is over 5 ℃ without water)

9. "E3" : FAN MOTOR Broken(no signal from HALL IC)

36

5. MOTOR

1) BLDC MOTOR

2) Driving mechanism of BLDC MOTOR

Magnetic density flow of BLDC Motor

Rotor

Insulator

Core

Insulator

BLDC MOTOR 의 구성

Sequence diagram of BLDC MOTOR electromagnet generating high power by rotator

(a permanent magnet) and stator

(multiple coils)

37

6. DRY SYSTEM

1) DRY SYSTEM

B

C

D

A I

E

F G J

38

H

DIVISION PARTS NAME

A DUCT COVER

B

C

D

FAN MOTOR

HEATER DRY

DUCT B UNDER

H

I

J

E

F

G

VALVE INLET(DRY)

THERMOSTAT(Bie-METAL)

THERMISTOR

DUCT B UPPER

FAN AS

FUSE TEMPERATURE

2) DRY FUNCTION DIAGRAM

DRY DUCT

T

T : Thermistor

(CONTROL

HEATER ’

TEMPERATURE )

HEATER

FAN MOTOR

WATER SUPPLY

CONDENSING

DUCT

DRUM

DRAIN

HOUSING

While rotating DRUM, DRY HEATER applice heat to air and FAN blows it into DRUM evaporating water in the laundry.

· Evaporated water is sucked into CONDENSING DUCT, and condensed in DUCT contacting WATER SUPPLY (condensed water is extracted through DRAIN HOUSING).

· Dry function is performed by continuous repetition of evaporating and condensing circulation as above.

3) TEMP-TIME GRAPH DURING DRY CYCLE

DRYING PROCESS

예열

ZONE

구간

DRUM

내부온도

39

4) DRY COURSE

COURSE

LOW TEMP.

IRON

DRY COURSE

Heater control temperature is 60 ℃ On/70 ℃ Off

Heater control temperature is 60 ℃ On/70 ℃ Off, with good condition for ironing

Heater control temperature is 87 ℃ On/95 ℃ Off, drying time is 166 min STANDARD

STRONG Heater control temperature is 87 ℃ On/95 ℃ Off, drying time is 216 min

SELECTING TIME Heater control temperature is 87 ℃ On/95 ℃ Off, customer can select the dryting time as

1Hr, 2Hr, 3Hr.

In order to check the drying temperature during process going on :

"DRY" button, the display shows as below.

--> press the

UPPER LED:

Temperature for DRY

The current temperature is 98 ℃

LOWER LED:

Temperature for WASH

40

5) TROUBLE SHOOTING OF DRY SYSTEM

HEATER DRY

Function : heating the air during dry

◎ FAILURE MODE : * "H7" - The air cannot be heated to 10 ℃ during 2 min.

◎ CHECKING METHOD : * Check the resistance of heater coil and replace with new one.

Thermistor

Function : sensing the air temperature.

◎ FAILURE MODE : * The air cannot be heated even though water is supplied.

* "H1" - shot or cut-off

* "H3" - air temp. is reached over 150 ℃

◎ CHECKING METHOD : * Check the resistance of thermistor, replace with new one.

FUSE TEMPERATURE

function : protecting from the fine hazard or overheating, if the temp., rises over 128 ℃ , power supply will be cut-off.

◎ Pictures

FIXED BY

WASHER

+

SCREW

◎ FAILURE MODE : Dry is not performed.

◎ CHECKING METHOD : Check if fuse is short, and replace with new one.

41

SWITCH THERMOSTAT(BIMETAL)

function : control the duct as remperature, if the temp reached over 150 ℃ , all power supply will be cut. and if the temp go down

120 ℃ the power will be ON.

protecting overheating by cutting off heater power supply if the temperature rises over 150 ℃ , and reoperating heater by connecting heater power supply if the temperature falls under 120 ℃ .

◎ PICTURE ◎ OPERATING TEMPERATURE

OPEN TEMPERATURE(OFF)

CLOSE TEMPERATURE(ON)

150

℃±

5

120

℃±

5

UNIT FAN MOTOR

function : circulating the inside air during dry process.

◎ SPEC

ITEMS

RATING VOLTAGE

RPM

MOTOR

DUCT FAN AS

ROTAING DIRECTION

SPEC

24V

3700 ± 10%

1900 ± 10%

CW

◎ PICTURE

◎ FAILURE MODE : * E3 shown : FAN MOTOR cannot work.

◎ CHECKING METHOD : Check the FAN MOTOR is short, and replace with new one.

42

6) FAR-INFRARED COATING

function : steilization with radiating far- infra red, by means of ceremic coating.

increasing the dry efficiency and effecting sterilization by radiating far infra-red ray from ceramic particle coating on DUCT

B UPPER

◎ principle

DUCT B UPPER FAR-INFRARED COATING DUCT B UPPER

43 pass heated air ---------> emit far-infra red coating area f a r - i n f r a

---------------------> steilization tub inside

The far infrared ray is emitted from the ceramic coating, comes into drum by radiation and reflection, and penetrates deeply into laundry with the effective moisture removal and sterilization.

7) LACK OF DRY PERFORMANCE

◎ Situation : after drying, the clothes still get wet.

cause) ☞ The laurdry amount is more than the recommendation capacity 7.0kg.

☞ Condensing cold water is not supplied.

☞ Clogging Bellows Duct results in poor air circulation.

checking method) part name

BELLOWS

DUCT checking point

BELLOW

DUCT checking results clogging bellows duct jurge heater was overheated owing to poor air circulation repair method clean the bellow duct

VALVE INLET

+Condensing

HOSE

VALVE

INLET

CONDENSI

NG HOSE no water supply from inlet valve

VALVE INLET connector slipped out connect normally

VALVE INLET broken replace valve inlet ill-connection of condensing hose to duct pipe connect normally

◎ Situation aftering drying, the clothes was soaked and hot.

cause) ☞ The dry is done from bad spin performance because of unbalance.

☞ no spin was done before the dry had started.

◎ Situation : PCB shows "H1" or "H3". cause) ☞ Thermistor is broken.

☞ Thermistor is short or cut-off.

countermeasures) ☞ replace the Thermistor.

44

◎ Situation : PCB shows "H7". cause) ☞ Dry heater is cut-off.

☞ Fuse temp. is cut-off.

repaire method) ☞ replace the Dry heater.

☞ replace the Fuse temp.

checking point part name

HEATER checking results dry Heater is short or cut-off.

SENSOR TEMP.

Thermistor is short or cut-off.

FUSE TEMP.

FUSE TEMPERATURE is cut-off.

repaire method replace the dry Heater.

replace the

Thermistor.

replace the

FUSE

TEMPERATURE.

HEATER

THERMISTOR

FUSE TEMPERATURE

45

◎ situation : PCB shows "E3".

cause) countermeasures)

☞ FAN MOTOR can not work.

☞ Replace the Fan Motor.

part name checking results

FAN MOTOR fan motor failure repair method replace fan motor disassemble process of Fan Motor

① Disassemble the DUCT AS from DUCT B AS.

(SCREW 4 EA)

DUCT COVER AS

Remarks) control times of each parts during dry process parts

MOTOR

DRAIN MOTOR

FAN MOTOR

DRY HEATER

INLET VALVE

Control time

10 sec On, 10sec Off

Continous working

Continous working

87 ℃ On, 95 ℃ Off

5sec On, 20sec Off

② Disassemble FAN AS from DUCT COVER AS by using

L-wrench.

2.5mm L-wrench

③ Disassemble FAN MOTOR .(SCREW 3EA)

46

7. WIRING DIAGRAM

1) DWD-E1211RT

1 2 3

1 2 3

AC POWER S/W

Hole 1. COMMON

Hole 2. NC

Hole 3. NO

E1211R

WF06

WF08:F/MOTOR

(RD)

1 2 3

1 2 3

BL RD BR

WF10:SENSOR

WF09:MOTOR

1 2

1 2

3 4

3 4

5

5

(WH)

6

6

7 8 9 10 11 12

7 8 9 10 11 12

BR OR GN YW PK GY WH VT BK

WF07

(WH)

1 2 3

1 2 3

PK VT BL

(BL)

1 2

1 2

RD RD

1 2

1 2

WF02:D/LOCK WF01:LOAD

MAIN PCB

BK

(RD)

1 2 3 4 5 6 7 8

1 2 4 5 6 7 8

GY VT BR

(WH)

1 2 3 4 5 6 7 8

1 2 3 4 5 6 7 8

GN OR YW BL BK WH

(WH)

1 2

1 2

GY VT

(WH)

1 2 3

RD OR BR

Vdd1

1 2

GND Signal

1 2 3

1 2

1 2

Tm1

WATER

SENSOR

PRESSURE

Tm2

DRY

(WH)

CON.010-SH

Hb

Gnd

Ha

5V

SENSOR HALL

U V W

(WH) CON.090-M

3 2 1

MOTOR MAIN(BLDC)

REACTOR

COLD PRE DRY

VALVE INLET

1 6 7 8 5 2 3 4 9

1 6 7 8 5 2 3 4 9

1 2

1 2

W V U

FAN MOTOR(24V BLDC)

WH BL

2 1

2 1

YB WR

BUBBLE PUMP MOTOR DRAIN

BK BL

THERMOSTAT . OFF : 150

YW

FUSE TEMPERATURE (DUCT

YW

2 3 4 5

HEATER DRY (1200W)

S/W

DOOR LOCK

EARTH OUTER

(TAIWAN,JAPAN)

HEATER WASH (1000W)

1 2

1 2

3

3

POWER CORD

~15A 125V

12A 125V

RELAY

3 4

3:P/CORD( ˆ»

4:W/HEATER(

ˆ»

WF03:HEATER

1:

2:

3:

D/HEATER

W/HEATER

P-CORD(COMMON)

WF04:S/W POWER

1:

ˆ»

2:

3:

4

1

(WH)

3

1

BL BL BL

WF05:REACTOR

2:

1:

1 2

1 2

3

3

2) DWD-E1211WT

AC POWER S/W

Hole 1. COMMON

Hole 2. NC

Hole 3. NO

E1211W

WF06

(RD)

1 2 3

1 2 3

BL RD BR

WF10:SENSOR WF09:MOTOR

BR

(WH)

1 2 3 4 5 6 7 8 9 10 11 12

1 2 3 4 5 6 7 8 9 10 11 12

GN YW PK GY WH VT BK

WF07

WF02:D/LOCK WF01:LOAD

(WH)

1 2 3

1 2 3

PK VT BL

MAIN PCB

(BL)

1 2

1 2

RD RD

(WH)

1 2 3 4 5 6 7 8

1 2 3 4 5 6 7 8

GN OR BL BK WH

1 2

1 2

ˆ»

(WH)

1 2

1 2

GY VT

(WH)

1 2 3

1 2 3

ß OR BR

(WH) CON.010-W/TH

1 2

GND Signal

Tm1

WATER

SENSOR

PRESSURE

Vdd1

U V

3 2

W

1

(WH)

CON.010-SH

Hb

Gnd

Ha

5V

SENSOR HALL

MOTOR MAIN(BLDC)

REACTOR

COLD PRE

VALVE INLET

WH

(WH) CON.010-B/P

(WH) CON.010

1 2

1 2

BL

2 1

2 1

YK WR

BUBBLE PUMP MOTOR DRAIN

BK BL

2 3 4 5

S/W

DOOR LOCK

EARTH OUTER

(TAIWAN,JAPAN)

HEATER WASH (1000W)

47

1 2 3

1 2 3

POWER CORD

~15A 125V

12A 125V

RELAY

3 4

3:P/CORD( ˆ»

4:W/HEATER( ˆ»

WF03:HEATER

1:

2:

3: ¥

W/HEATER

P-CORD(COMMON)

WF04:S/W POWER

2: ß

3: ¥

BL

(WH)

4 3

1 11

BL

WF05:REACTOR

2: ß

1: ß

1 2 3

1 2 3

3) DWD-E1221RT / DWD-E1223RT

WF06

WF08:F/MOTOR

WF10:SENSOR

WF09:MOTOR

1 2 3 4

(WH)

5 6 7 8 9 10 11 12

1 2 3 4 5 6 7 8 9 10 11 12

BR OR GN YW PK GY WH VT BK

WF07

(WH)

1 2 3

1 2 3

PK VT BL

(BL)

1 2

1 2

RD RD

1 2

1 2

WF02:D/LOCK

WF01:LOAD

MAIN PCB

1 2

(RD)

3 4 5 6 7 8

1 2 3 4 5 6 7 8

BK WH BL YW RD GY VT BR

1 2

(WH)

3 4 5 6 7 8

1 2 3 4 5 6 7 8

GN OR YW BL BK WH

(WH)

1 2

1 2

GY VT

(WH)

1 2 3

1 2 3

RD OR BR

Vdd1

1 2

GND Signal

1 2 3

1 2

1 2

Tm1

WATER

SENSOR

PRESSURE

Tm2

DRY

U

3

V

2

W

1

(WH)

CON.010-SH

Hb

Gnd

Ha

5V

SENSOR HALL

MOTOR MAIN(BLDC)

REACTOR

W V U

FAN MOTOR(24V BLDC)

COLD PRE DRY

VALVE INLET

1 6 7 8 5 2 3 4 9

1 6 7 8 5 2 3 4 9

(WH) CON.010

1 2

1 2

WH BL

2 1

YB

2

WR

1

BUBBLE PUMP MOTOR DRAIN

BK BL

THERMOSTAT . OFF : 150

YW

FUSE TEMPERATURE (DUCT

YW

2 3 4 5

HEATER DRY (1200W)

S/W

DOOR LOCK

EARTH OUTER

(TAIWAN,JAPAN)

HEATER WASH (1000W)

1 2 3

1 2 3

POWER CORD

~15A 125V

12A 125V

RELAY

3 4

3:P/CORD( ˆ»

4:W/HEATER( ˆ»

WF03:HEATER

1:

2:

3:

D/HEATER

W/HEATER

P-CORD(COMMON)

WF04:S/W POWER

2:

3:

RELAY 4

1

(WH)

3

1

BL BL BL

WF05:REACTOR

2:

1:

1 2 3

1 2 3

E1213R

4) DWD-E1221WT / DWD-E1223WT

E1213W

WF06

WF10:SENSOR WF09:MOTOR

BR

1 2 3 4 5

1 2 3 4 5

(WH)

6

6

7

7

8 9 10 11 12

8 9 10 11 12

GN YW PK GY WH VT BK

WF07

WF02:D/LOCK WF01:LOAD

(WH)

1 2

1 2

3

3

PK VT BL

MAIN PCB

(BL)

1 2

1 2

RD RD

1 2 3

(WH)

4 5 6 7 8

1 2 3 4 5 6 7 8

GN OR BL BK WH

1 2

1 2

ˆ»

(WH)

1 2

1 2

GY VT

(WH)

1 2 3

1 2 3

OR BR

(WH) CON.010-W/TH

1 2

GND Signal

1 2 3

Tm1

WATER

SENSOR

PRESSURE

Vdd1

U V

3 2

W

1

(WH)

CON.010-SH

Hb

Gnd

Ha

5V

SENSOR HALL

MOTOR MAIN(BLDC)

REACTOR

COLD PRE

VALVE INLET

WH

(WH) CON.010-B/P 1 2

1 2

BL

2

2

YK WR

BUBBLE PUMP MOTOR DRAIN

1

1

BK BL

2 3 4 5

S/W

DOOR LOCK

EARTH OUTER

(TAIWAN,JAPAN)

HEATER WASH (1000W)

48

RELAY

3 4

3:P/CORD(

ˆ»

4:W/HEATER( ˆ»

WF03:HEATER

1:

2: W/HEATER

3: ¥ P-CORD(COMMON)

WF04:S/W POWER

1: ˆ»

2: ß

3: ¥

4

1

(WH)

3

11

BLBL BLBL

WF05:REACTOR

2: ß

1: ß

1 2 3

1 2 3

1 2 3

1 2 3

POWER CORD

~15A 125V

12A 125V

8. TROUBLE SHOOTING REGARDING DRAIN

1. Drain Part Picture

HOSE DRAIN I

HOUSING VALVE

DRAIN MOTOR

VALVE AIR AS

2. Operating Sequence

DRAIN MOTOR connects drain passage by pulling LINK VALVE DRAIN. If the DRAIN MOTOR stops working,

LINK VALVE DRAIN returns to initial state by spring.

3. Check point when connecting hose drain O

① Keep the hose straight.

② Keep the end of hose not to dip in water.

4. Checking Methods

◎ Situation : * "OE" is shown on PCB.

* Not finishing drain during 10 min.

* The water level can not reach to RESET POINT during 10 min of drain.

Checking Methods

* Check the hose drain O condition; twisted or frozen.

Replacing methods

* replace HOSE DRAIN O

* clean the inside of COVER VALVE.

* Check the hose drain O condition, blocked.

* replace DRAIN MOTOR disassemble COVER

VALVE by turning and pulling

* DRAIN MOTOR is broken.

49

9. INSTALLATION GUIDE

1. PARTS & CONFIGURATION

PARTS NAME

FIXTURE UP/DOWN AS

UNIT SERVICE WRENCH

FIGURES

SPECIAL SCREW FIXTURE

UP DOWN

SPECIAL

SCREW

DOWN

REMARKS

SPECIAL SCREW UP

: L= 109mm

SPECIAL SCREW DOWN

:L=145mm

① Use this part to remove

FIXTURE UP/ DOWN.

② Adjust leg with this part.

LEG ADJUST AS

FIXTURE

LEG

FOOT

2. INSTALLATION PROCESS

① Remove the FIXTURE UP/DOWN AS

Removal Method Remarks

☞ Disassemble the FIXTURE UP/DOWN AS by turning CCW direction.

☞ Please keep FIXTURE UP/DOWN AS for later use.

☞ When fixing FIXTURE UP/DOWN AS, turn it CW direction.

② Insert CAP HOLDER(4EA) after removing FIXTURE UP/DOWN AS.

CAP HOLDER

50

③ Please install the DRUM WASHING MACHINE properly on even and hard floor as below.

④ Adjust the level of washer using LEG ADJUST AS.

Adjusting Method Remarks

☞ If turned CW, the LEG ADJUST AS moves the washer upward.

☞ If turned CCW, the LEG ADJUST AS moves the washer downward.

⑤ After adjusting level, fix SPECIAL BOLT.

Adjusting Method Remarks

☞ Please fix the SPECIAL BOLT by rotating it CCW in order to prevent washer vibration.

51

10. ATTENTION POINT WITH SERVICING

No Item Part Name

1 Replacing Thermistor Thermistor Dry

Dry

2 Replacing Duct B As DUCT B AS &

& Duct Pipe DUCT PIPE

Checking Point

Keep the Packing from seperating (Hold Packing when replacing)

Keep the Packing from folding

Check the sealing between Duct Pipe & Duct B AS

3 Replacing &

Repairing Inlet Valve

4 Replacing Hose Drain Hose Drain

5 Replacing HOSE

A,B,C

6 Replacing

Heater Wash

Inlet Valve

HOSE A,B,C

Use only screw M4*8 for fixing Inlet Valve

Keep the sealing condition of Tub O tightly

Check the assembling order between INLET BOX & Hose A,C :

Pre Wash-Cold

Unfastening the nut for fixing earth first then unfasten Heater Wash the nut for fixing heater

At assembling the heater dry, check if the assembling condition between fixture heater is tight.(little gap on left & right) At fastening the nut for fixing the heater wash, keep the protrusion length of bolt to 10~12mm.

7 Replacing

Thermistor Wash

Hinge Door ”

9 (Dis)assebling

Door AS ”

10 (Dis)assembling

“ Motor AS ”

(if under 10mm, water can leak, and if over 12mm, fixture heater can deform)

Thermistor Wash Unfasten the Nut for fixing heater, replace the thermistor, and fasten the nut for fixing heater

At fastening screw for fixing Door AS, be careful so that scratching at the related parts does not happen

: If the scratching happens, it is possible to be claimed about appearance damage

Door As Be careful about the up/down direction of Door Glass : Keep the indication point of the part code downward.

MOTOR AS To avoid the injury on the hand, grip the rim of the rotor

At initiating the assembling operation of the stator, grip the stator and fasten the screw; at unfastening the screw, grip the stator so that it does not fall.

52