advertisement
WDE1211001
DRUM WASHING MACHINE
Model : DWD-1211RT
DWD-1221RT
DWD-1223RT
JUL. 2005
DRUM WASHING MACHINE
SERVICE GUIDE
1. WHAT IS DRUM? .......................................................................................2
2. SPECIFICATION OF DRUM WASHING MACHINE ..................................6
3. VERIFICATION OF DRUM ASSY .............................................................7
4. PARTS LIST FOR EACH ASSY .................................................................8
5. SEQUENCE CHART OF PCB..................................................................20
6. SPECIFICATION OF ELECTRONIC PARTS ...........................................28
7. WIRING DIAGRAM ................................................................................. 47
8. TROUBLESHOOTING REGARDING DRAIN ..........................................49
9. INSTALLATION GUIDE ............................................................................50
10. ATTENTION POINT WITH SERVICE ....................................................52
1. WHAT IS DRUM ?
1. WHAT IS DRUM WASHER?
One of the famous washers in the globe which uses laundry falling energy.
2. Sales point of our washer
◈ The biggest capacity 12kg with compact size
◈ Envionmently friendly washer with NANO technology
• Sterilizing upto 99.9%
◈ No damage and entanglement but excellent washability
◈ 4way savings-noise, vibration, washing times, energy
◈ Self-cleaning course of Drum
◈ Good washing performance with heating system
◈ Condensing dry system with saving energy
◈ Sunshine dry effects with infrared x-ray
◈ Big door glass with easy laundry take-in/out
◈ The higest spin speed - 1200rpm
◈ No use of Drain pump ; good quality of drain and low noise
2
3. THE DRIVE SYSTEM OF DRUM WASHING MACHINE
DRAIN
MOTOR
WASH
TUB
DRUM
LIFTER
• DD CONTROL : DIRECT DRIVE TYPE
• BLDC MOTOR
BLDC
3
4. DRIVE SYSTEM
3. INLET PARTS
• COLD : 3-WAY
- COLD, PREWASH, DRY
• COLD : 2-WAY
- COLD, PREWASH
6. DRY PARTS
• HEATER DRY : 1200W
• BLOWER FAN
• FAN MOTOR : BLDC
• THERMISTOR
• THERMOSTAT
: FUSE, BI-METAL
• CONDENSING SYSTEM
• DRY FAN DRIVE
-> GENERATION OF
HEATER ’
-> TEMP. SENSOR
-> 95 ℃ OFF 87 ℃ ON
5. DOOR 부
• DOOR LOCK S/W
: WATER ADDING FUNCTION
• LOCK HINGE
• DOOR AS : GLASS
• GASKET
7. DRAIN
• DRAIN MOTOR
• VALVE HOUSING
4
4
8. SUPPORTER
• BASE
• DAMPER AS : 3(70N)
1. CONTROLLER
• MAIN PCB
• FRONT PCB
• HARNESS
• NOISE FILTER
• POWER CORD : 15A
2. DRIVE PARTS
• BLDC MOTOR
• DRUM
• BEARING
• SPIDER/SHAFT
• TUB
• WEIGHT BALANCER
4. WASH HEATING
• WASH HEATER : 1000W
• THERMISTOR
• 30 ℃ FIXED TEMP. CONTROL
• 50 ℃ ,60 ℃ BOIL
5. FUNCTION
3. INLET PARTS
• 3-WAY INLET VALVE
• 2-WAY INLET VALVE
• INLET BOX
1. CONTROLLER
• FRONT PCB
• NOISE FILTER
• MAIN PCB
5. DOOR AS
• GLASS
• HINGE
• DOOR LOCK S/W
• GASKET
8. SUPPORTER
• BASE
• DAMPER AS : 3(70N)
• SPRING : 4
7. DRAIN
• DRAIN MOTOR
• VALVE HOUSING
• HOSE
5
RAIN
RAIN MOTOR
ALVE HOUSING
OSE
5
6. DRY : DUCT AS
FAN MOTOR
FAN
HEATER DRY
BI-METAL S/W
TEMP. SENSOR
TEMP. FUSE
• LIFTER
• ROTOR
• STATOR
• SHAFT
• BEARING
BLDC MOTOR
DRIVE PARTS
• SPIDER
• DRUM
• TUB
• WEIGHT BALANCER
2. ROTATION
4. WASH HEATING
• WASH HEATER
• THERMISTOR
2. DRUM WASHING SPECIFICATION OF MACHINE
1. PANEL TYPE 1
DIMENSION(WxDxH)
MACHINE WEIGHT
WATER CONSUMPTION
WASHING CONSUMPTION
POWER SOURCE
POWER
CONSUMPTION
WASHING
DRY
WASHING
CAPACITY SPIN
DRY
WASHING TYPE
DRY TYPE
OPERATION WATER PRESSURE
630mm(W) x 755mm(D) x 950mm(H)
90 / 85 ㎏
WASH 155 ℓ / DRY 28 ℓ
45 ℓ
110V / 60Hz
1100W (Heating )
1250W
12 ㎏
12 ㎏
7.0
㎏
DRUM TYPE
Digital condensing dry system
29kPa ~ 784kPa(0.3
㎏ f/cm 2 ~8 ㎏ f/cm 2 )
12
13
14
15
8
9
10
11
6
7
4
5
NO
1
2
3
PARTS NAME
FRME DOOR O
DOOR WINDOW
DCD STICKER
PANEL LOWER
CABINET FRONT
PANEL LOWER
FRAME TOP F
FRAME TOP R
CABINET
PLATE TOP
CASE HANDLE
HANDLE CAP
BADGE
WINDOW DISPLAY
DECO. WINDOW
24
25
26
27
20
21
22
23
16 BUTTON DOOR UNLOCK
17 BUTTON FUNCTION
18
19
DECO. FUNCTION
PLATE DISPENSER
BUTTON POWER
BUTTON DIAL OUT
BUTTON DIAL IN
HANDLE CABINET
BASE UNDER
6
3. VERIFICATION OF DRUM ASSY
PLATE TOP ASS'Y : 7 EA
INLETBOX ASS'Y
PANEL F ASS'Y
PANEL 1 :20EA
PANEL 2: 17 EA
CABINET F ASS'Y : 19 EA
7
CABINET AS : 10 EA
DUCT B AS A + DUCT PIPE : 23 EA
7
BASE U AS : 8 EA TUB AS : 29 EA
4. PARTS LIST FOR EACH ASSY
1. THE EXPLODED VIEW OF INLET BOX ASSEMBLY
No.
PARTS NAME PARTS CODE DESCRIPTION
3612608300 ABS,
CASE HANDLE
SCREW TAPPING
3611139400 ABS,
3611139700
9121301208
ABS, DWD-E1221** / DWD-E1223**
T2S PAN 3X12 SUS
D03 CASE PP
D04 CAP 3610916600 PP
D05 INLETBOX 3617505310 FRPP
D06 NOZZLE AS 3618103510 NOZZLE TOP + UNDER
D07 PACKING 3614010000 EPDM
D08 HOSE INLET 3613266400 EPDM
D09 CLAMP AS 3611203200 SWC/SPC, ID=60
1
1
3613267000 EPDM,ID=10,OD=16,L=355mm
3613266600 EPDM,ID=10,OD=16,L=335mm
D12 CLAMP 3611203800 ID=15.5
VALVE INLET
3615415900 DR12AS, 100~130V, 95mA,5W(wash+ dry)
3615415800 DR12AS, 100~130V, 95mA,5W(wash only)
UNITS
1
1
1
1
2
1
REMARK
HANDLE CAP OF FIXED
1
INLETBOX/TUB R
2
1
1
PRE WASH
WASHING
4
1
1
COLD, 3-WAY
COLD, 2-WAY
8
2. THE EXPLODED VIEW OF PANEL F ASSEMBLY( TYPE 1, DWD-1211**)
No.
B01
B02
B03
B04
B05
B06
B07
PARTS NAME
PANEL F
HOLDER COURSE OUT
HOLDER COURSE IN
DECORATOR POWER
BUTTON POWER IN
BUTTON POWER OUT
BUTTON DOOR LOCK
B09
B16
B17
B18
B19
B10
B11
B12
B13
B14
B15
BUTTON FUNCTION
SCREW TAPPING
WINDOW DISPLAY
DECORATOR WINDOW
HOLDER POWER
HOLDER COURSE MAIN
BUTTON DIAL MIDDLE
BUTTON DIAL OUT
BUTTON DIAL IN
CUSTOM LED
CASE PCB F
PCB FRONT AS
PCB FRONT AS
SCREW TAPPING
PARTS CODE
3614282200
3613049000
3613048900
3611631000
3616602800
3616602900
3616602600
361163900
3616602700
7121301208
3615502700
3611630800
3613048800
3613049100
3616602400
3616602500
3616602300
3613014400
3611139600
PRPSSW1D13
PRPSSW1D14
7122401411
ABS
DESCRIPTION
ABS
ABS
ABS
ABS
ABS
ABS
ABS
ABS
T2S PAN 3X12 SUS
ABS
ABS
ABS
ABS
ABS
ABS
ABS
ABS
HIPS
DWD-E1211RT
DWD-E1211WT
T2S TRS 4X14 MFZN
9
1
3
2
1
1
1
1
1
UNITS
1
1
1
1
1
1
1
1
1
7
1
1
1
1
REMARK
2. THE EXPLODED VIEW OF PANEL F ASSEMBLY(TYPE 2, DWD-1221** / DWD-
No.
PARTS NAME
B02 WINDOW LED COURSE
B04 DECOATOR BUTTON POWER
B06 BUTTON DOOR OPEN
SCREW TAPPING
B08 HOLDER LED COURSE
B09 HOLDER LED CUSTOM
B10 CASE PCB F 3611139600
SCREW TAPPING
B11 PCB
B12 BUTTON DIAL OUT
B13 BUTTON DIAL IN
PARTS CODE
3614282300
3615502900
3613049400
3611631100
3616603100
361603200
3616603000
7121301208
3613049300
3613049200
HIPS
7122401411
PRPSSW2D10
3616603400
3616603300
3615502800
3611139700
DESCRIPTION
ABS(BK-8410AT)
ABS 1
ABS 1
T2S PAN 3X12 SUS
ABS 1
1
ABS 1
T2S TRS 4X14 MFZN
DWD-E1221RT
ABS 1
ABS 1
ABS(BK-8410AT)
UNITS
1
REMARK
3
7
1
1
10
3. THE EXPLODED VIEW OF CABINET F ASSEMBLY
11
No.
C02 PLATE HINGE SUPPORT
C03 HINGE DOOR 3612902700
C04 CAP HINGE DOOR
C05 SPECIAL BOLT
C06 SPRING DOOR
C07 CLAMP DOOR
C08 FRAME DOOR I.
C14
C17
C18
C20
PARTS NAME
FRAME DOOR O.
FRAME DOOR O.
PIN HANDLE 3618200100
HOOK DOOR 3613100700
SWITCH DOOR LROCK
PARTS CODE DESCRIPTION
3610811000
3614531500
Zn-DC Zn Coating 1
SGCC(GI), 1.6t 1
3610916500
3616030700
POM
FLANGE HEAD, 5X10
3615113800
3611204200
3612204700
3615202300
7115401608
3606001310
GLASS
3618304200
3612204600
HSW3, D=1.0, N=7
HSW3, D=1.4, L=1245mm
TB53(Heat-Resistance PP)
4X20
1
ABS,CR COATING,
3612204610
3611425600
3615113700
SUS, D=3.0, L=39 1
Zn-DC Zn Coating 1
ABS,UV SPRAY
3612608200
3619046410
ABS
DF'S 125V 16A PTC-SOLENOID
UNITS
1
REMARK
4
3
1
1
1
3
3
12
1
1
1
1
1
1
12
4. THE EXPLODED VIEW OF BASE U ASSEMBLY
No.
G02
G04
PARTS NAME
PCB AS
PCB AS
PCB AS
LINE FILTER AS
TRANS SMPS (DWD)
G07 FOOT
SPECIAL BOLT
PARTS CODE DESCRIPTION
PRPSSW1D03 DWD-E1211RT
PRPSSW1D04
PRPSSW2D03
PRPSSW2D04
3611908000
DWD-E1211WT
DWD-E1221RT, DWD-E1223RT
DWD-E1221WT, DWD-E1223WT
EMI
3610391900 PP
5EM1028010 T2S-V24,600uH(1~3)
3615303600 PO+Coating,
ABS
3612100600 BUTYL
4
3616029000 10 X 1.25, 51MM
13
1
1
4
UNITS
1
1
1
1
1
REMARK
4
4
5. THE EXPLODED VIEW OF TUB ASSEMBLY
14
No. PARTS NAME
H01 BALANCER WEIGHT AS (R)
H05 GASKET
H06 CLAMP GASKET AS
H07 SPRING SUSPENSION F
H08 TUB FRONT
H16
H17
H18
H25
H28
VALVE DRAIN AS
AIR TRAP AS 3610AAR100
SPRING SUSPENSION R
UNIT BUBBLE PUMP
H26 BASE
H27 UNIT MOTOR BLDC
UNIT ROTOR BLDC
PARTS CODE
3616106200
3614404900
3611204300
EPDM
3612320700
6.5KG
PP
MFZN
EPDM
DESCRIPTION
1
3611203600
3615113500
3618820400
3612006700
361A700200
361A700100
3617003300
361A400300
361A300200
36196TAK00
3615415100
WIRE
YELLOW
PP+GF, FH7303GM
SUS
PP
AKS(TURKEY)
SUS
AL+S45C
ASSY
1
3615113600
3612321100
EPDM
3616303100
3616303000
3616303200
BLACK
6506
AL
6205
1
3613266300
36189L4G00
EPDM
AC 100~130V,DBK-115DA
3610392000
36189L4000 WS2A28G001,310VDC
MAGNET24,SERRATION 36189L4900
3612801100 110V 1KW 12.1
Ω 6.1W/SQ SUS RW8TF 144 ℃
15
UNITS REMARK
2
1
1
2
1
1
1
1
1
1
1
1
1
1
1
3
3
1
1
1
1
1
1
1
2
6. THE EXPLODED VIEW OF DUCT B AS A + DUCT PIPE ASSEMBLY ( WASH +
16
No.
E01
E03
E06
E07
E08
E09
PARTS NAME
UNIT FAN MOTOR
DUCT B UPPER AS
SCREW TAPPING
SPECIAL WASHER
FUSE TEMPERATURE
FRAME HEATER FRANGE
PARTS CODE DESCRIPTION
36189L3Z00 ISM-77806DWWA 24V CW 8P 14W
AL 1
361A200600
3611203310
3611885700
AL, SUNSHINE DRY
DALE-3
7122400811
3616030300
361A800120
3612204100
ø 133x45L IMPELLER
T2S TRS 4x8
T1.0 OD=20 ID=4.3
128 ℃ (DF128S) 250V 15A
SBHG 1.0t
E10 DUCT B LOWER 361A200100 AL
3614009900 SILICON
3619046500 ON ℃ OFF 150 ℃ 230V 15A
DRY Ω 6.1W/SQ INCOLOY800 RL89 1
361AAAAC00 CWT-DEW-1C03
E17
E18
E21
GASKET SEAL A
GASKET SEAL B
DUCT PIPE AS
3614009800
3611562800
3612320800
3612320810
3612320900
SILICON
NBR
EPDM FOAM
EPDM FOAM
Asbestos
AL
361A200700 11KG
3611203700 DUCT
3616403000 EPDM
1
UNITS REMARK
1
1
1
1
1
1
4
1
1
1
1
1
1
1
1
2
1
1
1
1
17
7. THE EXPLODED VIEW OF CABINET ASSEMBLY
No.
F02
F03
PARTS NAME
FRAME TOP R
FRAME TOP L
F04 CABINET
F05 COVER BACK
PARTS CODE
3618103200 PP
3612204300
3612204900
GI, 1.6T
GI, 1.6T
DESCRIPTION
3610810900 SGCC,0.8T,PAINTING
3611425500 0.4T, SGCC
3615202200 POM
F10 FRAME LOWER
F11 SENSOR PRESSURE
F12 CORD POWER AS
3612608100 PP
3612204200 SBHG, 1.2T
3614825200
3611339810
5V DRUM,DL-DW01
VCTFK 2C 15A 125V
18
1
1
1
4
1
4
1
1
1
UNITS REMARK
1
1
1
8. THE EXPLODED VIEW OF PLATE TOP ASSEMBLY
No. PARTS NAME
A01 FRAME PLATE F
A02 FRAME PLATE R
A03 PLATE 3614531600
A05 FIXTURE PLATE T
SCREW TAPPING
PARTS CODE
3612204400
3612204500
3614110500
3612007100
3613553800
7122401411
DESCRIPTION
ABS
ABS
SPONGE
1
STAPLE
ART+OPP
T2S TRS 4X14 MFZN
UNITS REMARK
1
1
1
2
1
12
19
5. SEQUENCE CHART OF PCB
1. SEQUENCE CHART
Cotton
( 標 準 )
Syntheti c
Heavy
Stain
Proces Time
少 低 低 低
Pre.
Wash
預 洗 n g h i
W a s
R i n s e
S p i n
Sensing
Water Supply
Pre. Wash
Drain
Balancing Spin
Mid.Spin
Sensing
Water Supply
Washing1
(Heating)
Washing 2
Drain
Balancing Spin
Mid.Spin
Water Supply
Rinse 1
Drain
Balancing Spin
Mid.Spin
Water Supply
Rinse 2
Drain
Balancing Spin
Mid.Spin
Water Supply
Rinse 3
Drain
Balancing Spin
Main Spin
20sec
2min
10min
8min
1min
1min
3min
20sec
2min
95min
85min
45min
35min
30min
25min
20min
15min
1min
1min
3min
2min
3min
1min
1min
3min
2min
3min
1min
1min
3min
2min
3min
1min
1min
7min
5min
3min
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
27min
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
End
Cloths Release
END
Wrinkles Protect
NOTE
Over Time Indication
60sec
10sec
30min
■
■
■
1:32
■
■
■
1:37
■
■
■
1:34
■
■
1:59
1.Heavy Stain Course: Pre.Wash is Basic Default.
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
Whites
( 高 溫洗 衣 )
少 低
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
ECO( 省 電 )
少 低
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
60min
■
■
■
■
■
■
■
■
2:27 2:37 1:47 2:02
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
20
Proces Time
Wool
毛 衣
Delicate
高 級衣
Blanket Quick30
快 洗
Drain
槽 淨 n g h i
W a s
R i n s e
Soak
Water Supply
"Wash 1
(Heating)"
Wash 2
Drain
Balancing Spin
Mid.Spin
Water Supply
Rinse 1
Drain
Balancing Spin
Mid.Spin
Water Supply
Rinse 2
Drain
Balancing Spin
Mid.Spin
Water Supply
Rinse 3
Drain
Balancing Spin
30min
2min
60min
50min
35min
30min
12min
25min
15min
7min
1min
1min
3min
2min
3min
2min
3min
1min
1min
7min
3min
1min
1min
3min
2min
3min
1min
1min
少
■
■
■
■
■
■
■
■
■
■
■
少
■
■
■
■
■
■
■
■
■
■
■
低
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
低
■
■
■
■
■
■
■
■
■
■
■
■
■
中
■
■
10min
S p i n
■
■
■
■
■
■
■
■
D
R
Y
Mid.Spin
포풀림
Dry
Wrinkles Protect
Cloths Release
End
END
Over Time Indication
NOTE
Cooling
END
5min
3min
60sec
40min
18min
5min
10sec
30min
60sec
10sec ■
46
■
46
■
■
1:07
■
■
■
■
■
1:15
■
■
■
■
1:48
1. Quick30( 快洗 )/Drain( 槽洗淨 ) - Dry is Basic Default
2. 防皺行程 (wrinkle protect): 完成所有行程後,沒有取衣時才會進入防皺行程 .
3. Memory : 已經設定 _ 標準,使用者可調整 .
■
■
■
■
■
■
■
■
■
■
Memory
記 憶
21
2. Main function of PCB program
2-1. LOAD SENSING
1) Deciding the water level
① Cotton, Whites, ECO course will be followed by this process.
② Check the water level with dry laundry at the starting wash.
③ Check the water level by using motor output data during 20 sec, 65 rpm.
2) Balancer Spin
① Check after finishing washing step with wet laundry.
② Checking by using motor output data during 20 sec, 65 rpm.
③ The decided data is different depending on loading condition.
2-2. BALANCE SPIN
1) Motor running during balance spin.
① Spreading the laundry : Rotating the same 45 rpm with left and right direction alternatively.
② Attaching stop : Attaching the laundry to drum inside with constant speed.
Unbalance checking point : First step, check the U.B at 95 rpm, 160 rpm.
Second step, check the U.B at 95 rpm, 350 rpm.
Third step, at 300 rpm. if the unbalance data is over the criterion,
This process will be repeated.
④ Drain step : Drain at water around 160 rpm.
⑤ After drain, check the unbalance data again. This is so-called balance spin step.
2) Property of balance spin.
① Conducting 10 times maximum.
② If the washer can not pass balance spin step during 10 times, then water will be supplied.
③ If the washer can not pass 20 times of balance spin, UE error mode will be displayed on PCB.
③
22
2-3. DOOR S/W
1) The working principle of Door S/W
① Door Locking
Bimetal on ( 3 sec) --> solenoid (supply 20msec pulse 2 times)
② Door Unlocking
Bimetal off --> solenoid (supply 20msec pulse, until unlock)
③ After door locking, all parts can work normally.
④ After pressing power button, if the temperature of wash thermistor is over 50 ℃ or the water level is over the safety level, the door will be locked.
⑥ The door the will be unlocked immediately after all processes are finished.
⑦ The door can be opened during processing if there is no problem to unlock.
23
2) DOOR OPEN SYSTEM
① If add the laundry during washing, press the door unlock button.
② Door open sequence at abnormal condition.
start / hold door unlock button, 2sec.ON
water level is less than safety level?
YES
Temperature is less than 50 ℃ ?
YES
Display <LOCK> off
NO
NO drain fan motor on/ cold water supply
Door open
24
2-4. Child Lock
① Press the TEMP ” DRY button simultaneously during processing.
② Under the Child Lock function, only power button is working.
③ During Child Lock function, CHL will be displayed on PCB.
④ In orden to unlock Child Lock mode, press "TEMP" and "DRY" simultaneously.
2-5. The sequence of drain
① If the checking time to reset point is below 1 min, the remaining drain time is 30 sec.
② If the checking time to reset point is over 1 min, the remaining drain time is 2 min.
③ If the checking time to reset point is over 10 min, OE singal will be appeared on PCB.
④ If the temperature is over 50 ℃ , the water will be supplied to high water level, then the drain will start.
25
3. Convenience service functions(test mode)
1. Testing Mode
PCB and other electronic parts will be tested without water supply whether they are normal or not.
1) Process : press power button --> press "SPIN" button 3 times with pressing "WASH" button --> 'L d' will be shown on LED --
> Whenever pressing "TEMP" button 1 time, below process will be occurred.
L C (Lock Closed) --> F ( Fan Motor) ---> H (Hot V/V) --> C (Cold V/V) ->
P (prewashing V/V) -> d ( dry V/V) -> bb (bubble) -> dr (drain motor) ->
L O(Lock S/W Open)
2) More details
① When turn on 'LOCK' singal, all process is conducting normaly.
② When working starts, the PCB displys all the sensor conditions.
③ In this case, BLDC Motor is not tested. In order to test it, select spin or rinse.
2. Continous testing mode
1) Process : after pressing "WASH", "RINSE", "SPIN" button simultaniously, press "POWER" button.
ALL LED On/Off 1 time --> L C (Lock Closed) ---> R (Motor right) --> L (Motor Left) --> F ( Fan Motor) ---> H
(Hot V/V) --> C (Cold V/V) --> b (pre-wash V/V)
--> d ( dry V/V) --> bb (bubble) --> h1 (HEATER WASH)--> h2(HEATER DRY) --> dr (DRAIN MOTOR On) --
>L O(Lock S/W Open)
2) More tails
① LED test can be done with all LED On.
② All sensor conditions will be shown on PCB during processing.
26
4. ERROR DISPLAY
ERROR
SINGAL
IE
OE
UE
LE
E2
E3
E9
E5
E6
E7
E8
H1
H2
H3
H4
H6
H7
H8
ERROR CAUSE COUNTERPLAN
WATER
INLET ERROR
DRAIN
ERROR
① inlet valve broken
② drain motor working during water supply
③ pressure switch disorderChange the Sensor Pressure
④ PCB can not check water level
① drain motor out of order
② inlet valve working during drain
③ pressure switch disorderChange the Sensor Pressure
④ PCB can not check water level
UNBALANCE ERROR ① laundry unbalance
DOOR
① door opened during processing
② LOCK S/W broken
OPEN ERROR
③ PCB can not check door lockChange the PCB
① continuous water supplyChange the Inlet-Valve
Overflow
FAN MOTOR disorder
② drain motor can not workChange the Drain Motor
③ pressure switch disorderChange the Sensor Pressure
① fan motor cannot work
② PCB cannot control fan motor
SENSOR PRESSURE
ERROR
① abnormal water level
Change the Inlet-Valve
Change the Drain Motor
Change the PCB
Change the Drain Motor
Change the Inlet-Valve
Change the PCB rearrange the laundry
Clode the Door
Change the LOCK SW
Change the Fan-Motor
The contact of the Connector or Change the PCB
Change the Sensor Pressure
HIGH VOLTAGE
ERROR
EMG ERROR
Direction Error motor disorder sensor temp. dry disorder
① huge noise
② spining with jamming clothes between gasket
③ PCB broken
① huge noise
② spining with jamming clothes between gasket re-installation rearrange the laundry
Change the PCB re-installation rearrange the laundry
③ motor broken
④ PCB broken
① move opposite direction
② motor Hall IC broken
Change the Motor
Change the PCB check the connector and change
① connector problem The contact of the Connector
② abnormal loading conditioncheck the loading condition and change
① sensor temp broken
② connector problem
Change the Sensor Temp.
The contact of the Connector sensor temp.
wash disorder overheating dry heater
① sensor temp. of washing broken
② connector problem
① fan motor cannot spin
② sensor temp. of dry brokenChange the Sensor Temp.
overheating wash heater
① heater working with no water supply
② sensor temp. of wash brokenChange the Sensor Temp.
abnormal of washing heater ① washing heater cannot workChange the Heater Wash abnormal of drying heater ① dry heater cannot work
Change the Sensor Temp.
The contact of the Connector
Change the Fan Motor check water level
Change the Heater Dry abnormal of sensor temp. of washing
① heater working with no water supply check the water level and washing heater
27
6. SPECIFICATION OF ELECTRONIC PART
NO PART NAME
1 VALVE INLET (2-Way)
Rating (V/Hz)
Model
WASH+DRY WASH
PART CODE
110-130/50-60 ◎ 3615415800
BOM DESCRIPTION
100-130 2WAY PP/BRACKET
2 VALVE INLET (3-Way) 110-130/50-60
3 SENSOR PRESSURE
4 CORD POWER AS
5V
Taiwan:
3611339800
◎
◎
3615415900 100-130 3WAY PP/BRACKET
◎ 3614825200
5V DRUM, DL-DW01
5V DRUM, DN-DD01
◎ ◎ 3611339810 VCTFK 2C 15A 125V
5 UNIT BUBBLE PUMP
6 HARNESS AS
7 HARNSS EARTH
100-130/50-60
DWD-E1211RT
DWD-E1211WT
110 A11
8 FUSE TEMPERATURE 15A 250V
9 SWITCH DOOR LOCK 100-130/50-60
◎
◎
-
◎
◎
◎ 36189L4G00 100-130 DBK-115DA RP-CUSH
-
◎
3612793210 DRUM DRY-WASH-PO-NON HOT
3612793310 DRUM WASH ONLY-PO-NON-HOT
◎ 3612793400 GN/YW AWG18 FERRITE
361A800100 128 ℃ DF 128s 15A 250V
◎ ◎ 3619046410 DF ’
10 HWATER WASH
11 HEATER DRY
110/50-60
110/50-60
12 SWITCH THERMOSTAT 100-250V
UNIT MOTOR BLDC
13 UNIT STATOR BLDC
UNIT ROTOR BLDC
A11
14 THERMISTOR WASH
15 NTC THERMISTOR
16 UNIT FAN MOTOR
17 FAN AS
A11
Dry
Dry
Dry
18 DRAIN MOTOR
19 DAMPER FRICTION
20 DAMPER PIN
100-130/50-60
11kg A11
11kg A11
◎ ◎ 3612801100 110V 1KW 12.1
Ω 4.3W/SQ SUS 1R1A03305 144 ℃ IR1A033005
◎
◎
◎
◎
◎
◎
◎
◎
◎
◎
3612801300 110V 1.2KW 23.0
Ω 6.1W/SQ INCOLOY800 1R1A034001
3619046500 ON 120 ℃ OFF 150 ℃ 230V 15A VDE
36189L4000 3254D02000, 3114D02000, 310V, 250W
36189L4800 Φ 265X28H, 36SLOT, 25NESOR, 3254D02000 ◎
36189L4900 MAGNET24, SERRATION, 3114D02000
◎ 361AAAAB00 R25=11, 981 ㏀ , R80=1, 704 ㏀
361AAAAC00 R40=26, 065 ㏀ , R90=4, 4278 ㏀
36189L3Z00 ISM-77806DWWA 24V CW 8P 14W
3611885700 Φ 133x45L IMPELLER
◎ 36196TAK00 SV-HJ7T20D 100-110V ST23(56.5)
◎ 361A700100 70N AKS ST=170-245 DL=197.5
◎ 361A700200 AKS D=14.5
IR1A034005
NT-103NA
3254D02000,
3114D02000
CWT-DEW-1C03-0
CWT-DEW-1C02-0
ISM-77806DWWA
-
SV-HJ7T20D
-
-
TYPE
DR12AS
DR12AS
DL-DW01
DN-DD01
LP-70
DBK-115DA
-
-
-
DF128s
DF
28
1
TYPE
Material / Certi
Material Certi OPTION
Specification
SPEC
DR12AS
DR12AS
DL-DW01
DN-DD01
LP-70
DBK-115DA
-
-
-
DF128s
DF
IR1A033005
PP
PP
HIPS
-
-
-
PVC
-
-
PA66
SUS321
IR1A034005 INCOLOY800
X
X
X
BSMI R31050
X
X
X
X
VDE
IMQ CA02. 01619
VDE 72709
VDE 62726
VDE 119277
PRE-COLD,
SUS FILTER
PRE-COLD-DRY
SUS FILTER
3P-PCB,
BRACKET
Comply with PLUG-15A, 125V, CABLE:2. 0SQ VCTFK 2C
CNS3199, CNS10917 CABLE MARKING : R31050 VCTFK 300V 2C 2.00
- 2, CNS690
HOSE, CUSHION xxxx --LINETEK-- LF ”
HOSE Φ 4 L830(BL), UL1015AWG22 L230, MG621164(WH)
KET 1806 DL CONN UL1015 AWG18:HEATER, UL1015 AWG22:AC LOAD, UL1007 AWG22:DC LOAD
KET 1806 DL CONN UL1015 AWG18:HEATER, UL1015 AWG22:AC LOAD, UL1007 AWG22:DC LOAD
THERMAL
FUSE, BRACKET
-
-
-
BI-METAL, SOLEN0ID
BRACKET
RING TERM, ST710489-3x2-ST710946-3
UL1015 AWG18(AWG16) GREEN/YELLOW
FUSE 128 ℃ DF128S 15A/250V, TUBE SRGT(IDΦ 5)WH,
L/W UL1015 AWG18 105 ℃ 600V
PA66 25% GF V0, ,ICOW S/W(BI-M) 16A 125V,
SOLENOID 125V 130 Ω , PTC HEATER
THERMAL FUSE 167 ℃ , TUBE AISI321(SUS321),
Mg0 INSULATION, SEALANT EPOXY 120 ℃
TUBE INCOLOY800, INSULATION Mg0, GASKET SILICONE,
INSULATING BUSHING CERAMIC, SEALANT FPOXY 120 ℃
NT-103NA(5XV) F150-120, ± 5 ℃ NT-103NA
3254D02000,
3114D02000
CWT-DEW-1C03-0
CWT-DEW-1C02-0
ISM-77806DWWA
-
SV-HJ7T20D
-
-
MP
AS
STATOR
ROTOR
SUS
SUS
-
ALDC
-
-
X
X
X
X
X
X
OUTER ROTOR
-
SIDE SPONGE
-
-
-
B25/100=3760K
B25/85=3992K
±
±
2%
2%, L/W UL1007 AWG24 L=120, MG621164(KET)
DAMPER(70N)+PIN
28
1. VALVE INLET
1) CLASS
DIVI
SION
3-WAY
VALVE
2-WAY
VALVE
PARTS BODY
NAME COLOR SPEC
USE
COIL resistance
FLUX(100~240V 기준 )
0.2kgf
㎠ 1.0kgf
㎠ 3.0kgf
㎠ 5.0kgf
㎠ 8.0kgf
㎠
PRE-WASH
VALVE
4320~5280 Ω 2~5 ℓ 7~12 ℓ 8~13 ℓ 8~13 ℓ 8~13 ℓ
3615415000 IVORY PP MAIN
4320~5280 Ω 2~5 ℓ 7~12 ℓ 8~13 ℓ 8~13 ℓ 8~13 ℓ
VALVE
3615414900 BLUE PP
DRY VALVE 4320~5280 Ω
PRE-WASH
0.2~1.2
ℓ
4320~5280 Ω 2~5 ℓ 7~12 ℓ 8~13 ℓ 8~13 ℓ 8~13 ℓ
VALVE
MAIN WASH
4320~5280 Ω 2~5 ℓ 7~12 ℓ 8~13 ℓ 8~13 ℓ 8~13 ℓ
VALVE
29
2) TROUBLE SHOOTING
TROUBLE
WATER IS
SUPPLIED
SITUATION
NO WATER
SUPPLY WITH
"WING" SOUND
CAUSE closed water tap coil short alien materal jammed alien material inside inlet valve unfixing connector
CHECK POINT check the water tap opened check the resistance 4320~5280 Ω check the filter
-
NO WATER
SUPPLY
WITH SILENCE check the connector coil short
WATER
SUPPLY
IS NOT
STOPPED
Etc
THE WATER
SUPPLY START
WHEN POWER
"ON"
THE WATER
SUPPLY START
WHEN POWER
"OFF" water leakage to the side harness short pressure s/w broken pressure hose broken inlet valve broken inlet valve poorly assembled
Checking method of coil resistance, harness, connector.
check the resistance 4320~5280 Ω check the connector check the pressure switch check the hose torn or twisted
check the leakage of inlet valve
MAIN PCB "8P" WHITE
CONNECTOR
SOLUTION
Open the water tap
PCB
ERROR MODE
"IE"
"IE"
"IE" Clean the filter
Change the Inlet-
Valve
The contact of the
Connector
Change the Inlet-
Valve
"IE"
"IE"
"IE"
"IE"
Change the Sensor
Pressure
Change the bad parts
Change the Inlet-
Valve
"E2"
"E2"
-
Change the Inlet-
Valve
WASH VALVE(GREEN) :
COMMON(BLUE)/RESISTANCE TEST
PRE-WASH VALVE(RED) :
COMMON(BLUE)/RESISTANCE TEST
DRY VALVE(YELLOW) :
COMMON(BLUE)/RESISTANCE TEST
COMMON(BLUE)
-
* "IE" ERROR : lack of water supply
30
2. PRESSURE SWITCH
TROUBLE SITUATION continuously inlet valve is normal, water supply but continuous water supply
CAUSE bellows problem
CHECK POINT frequency Check : refer to below hose problem
"E9"
ERROR water level frequence below 15kHz or over
30kHz clogged hose connector slipped out pressure switch broken connector short
Checking method of coil registance, harness, connector.
frequency Check : refer to below check the fine hole check the hose condition check the connector condition frequency Check : refer to below connector broken
SOLUTION
PCB
ERROR MODE
"E2" change the pressure switch change the hose change the hose remove the alien reconnecting change the pressure switch
"E2"
"E2"
"E2"
"E9"
"E9"
"E9"
GROUND(GRAY)
INPUT SIGNAL(WHITE)
OUPUT SIGNAL
(PINK)
"12P" WHITE CONNECTOR
* E2 : overflow error ;Water level is higher than overflow level because of continuous water supply.
E9 : Pressure switch trouble, the frequency is less than 15kHz or more than 30kHz in the processing.
31
3. DOOR LOCK SWITCH
1) CLASS
Failure
Status
Tick Sound
"LE" Error
Details
Tick Sound happens
"LE" with tick sound
"LE" without tick sound
Cause
Normal Sound
Connector slipped out
DOOR closed loosely
Failure of DOOR HOOK
CATCH CAM broken
Connector slipped out
Diagnosis of Failure Solution
When Door is locked/unlocked, this Solenoid Working sound is heard.
check the joining status of Assemble Connector
-
connector by eye
Tick sound happen check the joining status of connector by eye
Close Door securely
Replace DOOR AS
Replace DOOR S/W
Assemble Connector
PCB
ERROR MODE
-
"LE"
"LE"
"LE"
"LE"
"LE"
Terminal slipped out Refer to below checking method.
Refer to below checking
Insert Receptacle no.2
or no.3
Replace DOOR S/W
"LE"
Solenoid Coil
Disconnection method.
"LE"
During operation, "Power Failure" or "Forced Power S/W OFF" causes door not to be opened until maximum 5 minutes pass.
DOOR not open
Power Failure/Forced
Power Off during operation
Power on state Water remained in tub Check whether the water level is over safety level.
After draining water, open the door
-
ETC hot temp. in tub
Follow below process
Prevent the burn due to hot temp. after dry.
Checking Method of wiring/coil disconnection, connector slipping out on PCB board : Operate with the Door lock switch connected
1. Replacing method of DOOR LOCK SWITCH
1) Open DOOR, disassemble CLAMP SPRING for fixing gasket
2) Disassemble GASKET
3) Disassemble two screws 5 for DOOR LOCK S/W
4) Disassemble DOOR LOCK S/W
5) Assemble in the reverse order
32
2. Checking method of DOOR LOCK SWITCH
PIN
array
2 3 4 5
(No no.1)
3. Checking method of DOOR LOCK SWITCH
Between Viloet and Blue wire
: If 156 ~ 234 Ω , it is normal
Between No. 3 & No.4
: if 156 ~ 234 Ω , it is normal
33
4. HEATER
1) SPEC. OF HEATER
Part Name
Maker
Power source
Power Consumption
Resistance
Current Density
Temperature fuse
Thermistator
Material
Part Code heater wash
IRCA
110V
1000W ± 5%
12.1
4.3
144 ℃
Combined in heater
SUS430
361280110
1. Temperature fuse
• If the heater is on without water, because of pressure switch trouble, fire can be occurred.
Temperature fuse prevents this hazard of fire.
• The heater wash must be submerged in water.
heater dry
IRCA
110V
1200W ± 5%
10.08
3.5
128 ℃ (exterior) exterior
INCLOY800
3612801300
2. The device for overheating prevention of the dry heater
• Temperature fuse : 128 ℃ cut-off type, 250V 15A
• Thermostat : 150 ℃ off 120 ℃ on,230V 15A
34
2) DIAGNOSIS OF THE FAILURE
Failure
Status
Can not heat water
Cause Diagnosis of Failure Solution
PCB
Error Mode
"H6"
Overheat water
Can not dry
Wiring Disconnectiona
Heater Wash
Disconnection
Connector/Terminal
Seclusion
Heater Wash/Thermistor
Wash Poor
Heater Wash/Thermistor
Wash Poor
Wiring Disconnection
Check whether disconnected or not : See Fig. A
Check whether disconnected or not : if normal, the resistance between two ends is 23.3~25.7
Ω .
Check whether disconnected or not : See Fig. A
Measure the resistance of two ends of the sensor : refer to the attached temp./resistance table
Measure the resistance of two ends of the sensor : refer to the attached temp./resistance table
Check whether disconnected or not : See Fig. B
Connecting the disconnecting point
Replacing Heater Wash
Inserting terminal/connector tightly
Replacing temp. sensor
Replacing temp. sensor
Connecting the disconnecting point
Replacing Heater Wash
Replacing Fuse Temp.
"H2"
"H6"
"H6"
"H2"
또는
"H7"
"H4"
Heater Dry Disconnection
Fuse Temp.
Check whether disconnected or not : if normal, the resistance between two ends is 22.3~24.7
Ω .
Shipped out Check the connection of two ends of fuse temp.
Check whether disconnected or not : See Fig. B
Inserting terminal/connector tightly
Replacing Fan Motor
"H7"
"H7"
Connector/Terminal
Slipped out
Operation Trouble of FAN
MOTOR Excessive Noise : Restraint/Failure of Fan Motor
Reassembling the Fan
Replacing temp. sensor
Heater Wash/Thermistor
Wash Failure
Fan slipped out : MOTOR is operating, but there is rotating sound.
Measure the resistance of two ends of the sensor : refer to the attached temp./resistance table
Checking Method of wiring/coil disconnection, connector slipping out on PCB board : Operate with the heater connected
"H7"
"H7" 또는 "E3"
"H7"
"H1"
[Figure A] * Inspect Wiring/Heater
Wash Disconnection :
Check the current and resistance of two terminals
[Figure B]
3P Connector orange wire
1P Connector
Blue Wire
* Inspect
Wiring/Heater Dry
Disconnection :
Check the current and resistance of two terminals
3P Connector
Red Wire
1P Connecor
Blue Wire
35
* Replaceing method of Heater and Temp. Sensor
1. Disassemble Connector
2. Disassemble EARTH and NUT for fixing heater
3. Replace heater & sensor
4. Assemble in the reverse order. Be sure to assemble in the order : Nut for heater-Nut for EARTH.
* Structure of DUCT B As
1. Heater Dry
2. Diecasting DUCT
3. Thermistor Dry
4. FAN MOTOR
5. Fuse Temp.
6. Switch Bimetal
7. FAN
* ERROR MODE
1. "H1" : Thermistor Dry OPEN/SHORT
2. "H2" : Thermister Wash OPEN/SHORT
3. "H3" : Dry Overheating(Sensing Temp. is over 125 ℃ )
4. "H4" : Wash Overheating(Sensing Temp. is over 95 ℃ )
5. "H5" : Wash Overheating
(In Wool, Lingerie courses sensing temp. is over 45 ℃ )
6. "H6" : Abnormal condition of Heater Wash
(when the temp. increase at 10 minutes after heater operation is under 10
℃ )
7. "H7" : Abnormal condition of Heater Dry(when the temp. increase at 10 minutes after heater operation is under 10 ℃ )
8. "H8" : Heater Wash Overheating
(when the temp. increase within 30sec after heater operation is over 5 ℃ without water)
9. "E3" : FAN MOTOR Broken(no signal from HALL IC)
36
5. MOTOR
1) BLDC MOTOR
2) Driving mechanism of BLDC MOTOR
Magnetic density flow of BLDC Motor
Rotor
Insulator
Core
Insulator
BLDC MOTOR 의 구성
Sequence diagram of BLDC MOTOR electromagnet generating high power by rotator
(a permanent magnet) and stator
(multiple coils)
37
6. DRY SYSTEM
1) DRY SYSTEM
B
C
D
A I
E
F G J
38
H
DIVISION PARTS NAME
A DUCT COVER
B
C
D
FAN MOTOR
HEATER DRY
DUCT B UNDER
H
I
J
E
F
G
VALVE INLET(DRY)
THERMOSTAT(Bie-METAL)
THERMISTOR
DUCT B UPPER
FAN AS
FUSE TEMPERATURE
2) DRY FUNCTION DIAGRAM
DRY DUCT
T
T : Thermistor
(CONTROL
HEATER ’
TEMPERATURE )
HEATER
FAN MOTOR
WATER SUPPLY
CONDENSING
DUCT
DRUM
DRAIN
HOUSING
While rotating DRUM, DRY HEATER applice heat to air and FAN blows it into DRUM evaporating water in the laundry.
· Evaporated water is sucked into CONDENSING DUCT, and condensed in DUCT contacting WATER SUPPLY (condensed water is extracted through DRAIN HOUSING).
· Dry function is performed by continuous repetition of evaporating and condensing circulation as above.
3) TEMP-TIME GRAPH DURING DRY CYCLE
DRYING PROCESS
예열
ZONE
구간
DRUM
내부온도
39
4) DRY COURSE
COURSE
LOW TEMP.
IRON
DRY COURSE
Heater control temperature is 60 ℃ On/70 ℃ Off
Heater control temperature is 60 ℃ On/70 ℃ Off, with good condition for ironing
Heater control temperature is 87 ℃ On/95 ℃ Off, drying time is 166 min STANDARD
STRONG Heater control temperature is 87 ℃ On/95 ℃ Off, drying time is 216 min
SELECTING TIME Heater control temperature is 87 ℃ On/95 ℃ Off, customer can select the dryting time as
1Hr, 2Hr, 3Hr.
In order to check the drying temperature during process going on :
"DRY" button, the display shows as below.
--> press the
UPPER LED:
Temperature for DRY
분
The current temperature is 98 ℃
LOWER LED:
Temperature for WASH
40
5) TROUBLE SHOOTING OF DRY SYSTEM
◈
HEATER DRY
Function : heating the air during dry
◎ FAILURE MODE : * "H7" - The air cannot be heated to 10 ℃ during 2 min.
◎ CHECKING METHOD : * Check the resistance of heater coil and replace with new one.
◈
Thermistor
Function : sensing the air temperature.
◎ FAILURE MODE : * The air cannot be heated even though water is supplied.
* "H1" - shot or cut-off
* "H3" - air temp. is reached over 150 ℃
◎ CHECKING METHOD : * Check the resistance of thermistor, replace with new one.
◈
FUSE TEMPERATURE
function : protecting from the fine hazard or overheating, if the temp., rises over 128 ℃ , power supply will be cut-off.
◎ Pictures
FIXED BY
WASHER
+
SCREW
◎ FAILURE MODE : Dry is not performed.
◎ CHECKING METHOD : Check if fuse is short, and replace with new one.
41
◈
SWITCH THERMOSTAT(BIMETAL)
function : control the duct as remperature, if the temp reached over 150 ℃ , all power supply will be cut. and if the temp go down
120 ℃ the power will be ON.
protecting overheating by cutting off heater power supply if the temperature rises over 150 ℃ , and reoperating heater by connecting heater power supply if the temperature falls under 120 ℃ .
◎ PICTURE ◎ OPERATING TEMPERATURE
OPEN TEMPERATURE(OFF)
CLOSE TEMPERATURE(ON)
150
℃±
5
℃
120
℃±
5
℃
◈
UNIT FAN MOTOR
function : circulating the inside air during dry process.
◎ SPEC
ITEMS
RATING VOLTAGE
RPM
MOTOR
DUCT FAN AS
ROTAING DIRECTION
SPEC
24V
3700 ± 10%
1900 ± 10%
CW
◎ PICTURE
◎ FAILURE MODE : * E3 shown : FAN MOTOR cannot work.
◎ CHECKING METHOD : Check the FAN MOTOR is short, and replace with new one.
42
6) FAR-INFRARED COATING
function : steilization with radiating far- infra red, by means of ceremic coating.
increasing the dry efficiency and effecting sterilization by radiating far infra-red ray from ceramic particle coating on DUCT
B UPPER
◎ principle
DUCT B UPPER FAR-INFRARED COATING DUCT B UPPER
43 pass heated air ---------> emit far-infra red coating area f a r - i n f r a
---------------------> steilization tub inside
The far infrared ray is emitted from the ceramic coating, comes into drum by radiation and reflection, and penetrates deeply into laundry with the effective moisture removal and sterilization.
7) LACK OF DRY PERFORMANCE
◎ Situation : after drying, the clothes still get wet.
cause) ☞ The laurdry amount is more than the recommendation capacity 7.0kg.
☞ Condensing cold water is not supplied.
☞ Clogging Bellows Duct results in poor air circulation.
checking method) part name
BELLOWS
DUCT checking point
BELLOW
DUCT checking results clogging bellows duct jurge heater was overheated owing to poor air circulation repair method clean the bellow duct
VALVE INLET
+Condensing
HOSE
VALVE
INLET
CONDENSI
NG HOSE no water supply from inlet valve
VALVE INLET connector slipped out connect normally
VALVE INLET broken replace valve inlet ill-connection of condensing hose to duct pipe connect normally
◎ Situation aftering drying, the clothes was soaked and hot.
cause) ☞ The dry is done from bad spin performance because of unbalance.
☞ no spin was done before the dry had started.
◎ Situation : PCB shows "H1" or "H3". cause) ☞ Thermistor is broken.
☞ Thermistor is short or cut-off.
countermeasures) ☞ replace the Thermistor.
44
◎ Situation : PCB shows "H7". cause) ☞ Dry heater is cut-off.
☞ Fuse temp. is cut-off.
repaire method) ☞ replace the Dry heater.
☞ replace the Fuse temp.
checking point part name
HEATER checking results dry Heater is short or cut-off.
SENSOR TEMP.
Thermistor is short or cut-off.
FUSE TEMP.
FUSE TEMPERATURE is cut-off.
repaire method replace the dry Heater.
replace the
Thermistor.
replace the
FUSE
TEMPERATURE.
HEATER
THERMISTOR
FUSE TEMPERATURE
45
◎ situation : PCB shows "E3".
cause) countermeasures)
☞ FAN MOTOR can not work.
☞ Replace the Fan Motor.
part name checking results
FAN MOTOR fan motor failure repair method replace fan motor disassemble process of Fan Motor
① Disassemble the DUCT AS from DUCT B AS.
(SCREW 4 EA)
DUCT COVER AS
Remarks) control times of each parts during dry process parts
MOTOR
DRAIN MOTOR
FAN MOTOR
DRY HEATER
INLET VALVE
Control time
10 sec On, 10sec Off
Continous working
Continous working
87 ℃ On, 95 ℃ Off
5sec On, 20sec Off
② Disassemble FAN AS from DUCT COVER AS by using
L-wrench.
2.5mm L-wrench
③ Disassemble FAN MOTOR .(SCREW 3EA)
46
7. WIRING DIAGRAM
1) DWD-E1211RT
1 2 3
1 2 3
AC POWER S/W
Hole 1. COMMON
Hole 2. NC
Hole 3. NO
E1211R
WF06
WF08:F/MOTOR
(RD)
1 2 3
1 2 3
BL RD BR
WF10:SENSOR
WF09:MOTOR
1 2
1 2
3 4
3 4
5
5
(WH)
6
6
7 8 9 10 11 12
7 8 9 10 11 12
BR OR GN YW PK GY WH VT BK
WF07
(WH)
1 2 3
1 2 3
PK VT BL
(BL)
1 2
1 2
RD RD
1 2
1 2
WF02:D/LOCK WF01:LOAD
MAIN PCB
BK
(RD)
1 2 3 4 5 6 7 8
1 2 4 5 6 7 8
GY VT BR
(WH)
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
GN OR YW BL BK WH
(WH)
1 2
1 2
GY VT
(WH)
1 2 3
RD OR BR
Vdd1
1 2
GND Signal
1 2 3
1 2
1 2
Tm1
WATER
SENSOR
PRESSURE
Tm2
DRY
(WH)
CON.010-SH
Hb
Gnd
Ha
5V
SENSOR HALL
U V W
(WH) CON.090-M
3 2 1
MOTOR MAIN(BLDC)
REACTOR
COLD PRE DRY
VALVE INLET
1 6 7 8 5 2 3 4 9
1 6 7 8 5 2 3 4 9
1 2
1 2
W V U
FAN MOTOR(24V BLDC)
WH BL
2 1
2 1
YB WR
BUBBLE PUMP MOTOR DRAIN
BK BL
THERMOSTAT . OFF : 150
YW
FUSE TEMPERATURE (DUCT
YW
2 3 4 5
HEATER DRY (1200W)
S/W
DOOR LOCK
EARTH OUTER
(TAIWAN,JAPAN)
HEATER WASH (1000W)
1 2
1 2
3
3
POWER CORD
~15A 125V
12A 125V
RELAY
3 4
3:P/CORD( ˆ»
4:W/HEATER(
ˆ»
WF03:HEATER
1:
2:
3:
D/HEATER
W/HEATER
P-CORD(COMMON)
WF04:S/W POWER
1:
ˆ»
2:
3:
4
1
(WH)
3
1
BL BL BL
WF05:REACTOR
2:
1:
1 2
1 2
3
3
2) DWD-E1211WT
AC POWER S/W
Hole 1. COMMON
Hole 2. NC
Hole 3. NO
E1211W
WF06
(RD)
1 2 3
1 2 3
BL RD BR
WF10:SENSOR WF09:MOTOR
BR
(WH)
1 2 3 4 5 6 7 8 9 10 11 12
1 2 3 4 5 6 7 8 9 10 11 12
GN YW PK GY WH VT BK
WF07
WF02:D/LOCK WF01:LOAD
(WH)
1 2 3
1 2 3
PK VT BL
MAIN PCB
(BL)
1 2
1 2
RD RD
(WH)
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
GN OR BL BK WH
1 2
1 2
ˆ»
(WH)
1 2
1 2
GY VT
(WH)
1 2 3
1 2 3
ß OR BR
(WH) CON.010-W/TH
1 2
GND Signal
Tm1
WATER
SENSOR
PRESSURE
Vdd1
U V
3 2
W
1
(WH)
CON.010-SH
Hb
Gnd
Ha
5V
SENSOR HALL
MOTOR MAIN(BLDC)
REACTOR
COLD PRE
VALVE INLET
WH
(WH) CON.010-B/P
(WH) CON.010
1 2
1 2
BL
2 1
2 1
YK WR
BUBBLE PUMP MOTOR DRAIN
BK BL
2 3 4 5
S/W
DOOR LOCK
EARTH OUTER
(TAIWAN,JAPAN)
HEATER WASH (1000W)
47
1 2 3
1 2 3
POWER CORD
~15A 125V
12A 125V
RELAY
3 4
3:P/CORD( ˆ»
4:W/HEATER( ˆ»
WF03:HEATER
1:
2:
3: ¥
W/HEATER
P-CORD(COMMON)
WF04:S/W POWER
2: ß
3: ¥
BL
(WH)
4 3
1 11
BL
WF05:REACTOR
2: ß
1: ß
1 2 3
1 2 3
3) DWD-E1221RT / DWD-E1223RT
WF06
WF08:F/MOTOR
WF10:SENSOR
WF09:MOTOR
1 2 3 4
(WH)
5 6 7 8 9 10 11 12
1 2 3 4 5 6 7 8 9 10 11 12
BR OR GN YW PK GY WH VT BK
WF07
(WH)
1 2 3
1 2 3
PK VT BL
(BL)
1 2
1 2
RD RD
1 2
1 2
WF02:D/LOCK
WF01:LOAD
MAIN PCB
1 2
(RD)
3 4 5 6 7 8
1 2 3 4 5 6 7 8
BK WH BL YW RD GY VT BR
1 2
(WH)
3 4 5 6 7 8
1 2 3 4 5 6 7 8
GN OR YW BL BK WH
(WH)
1 2
1 2
GY VT
(WH)
1 2 3
1 2 3
RD OR BR
Vdd1
1 2
GND Signal
1 2 3
1 2
1 2
Tm1
WATER
SENSOR
PRESSURE
Tm2
DRY
U
3
V
2
W
1
(WH)
CON.010-SH
Hb
Gnd
Ha
5V
SENSOR HALL
MOTOR MAIN(BLDC)
REACTOR
W V U
FAN MOTOR(24V BLDC)
COLD PRE DRY
VALVE INLET
1 6 7 8 5 2 3 4 9
1 6 7 8 5 2 3 4 9
(WH) CON.010
1 2
1 2
WH BL
2 1
YB
2
WR
1
BUBBLE PUMP MOTOR DRAIN
BK BL
THERMOSTAT . OFF : 150
YW
FUSE TEMPERATURE (DUCT
YW
2 3 4 5
HEATER DRY (1200W)
S/W
DOOR LOCK
EARTH OUTER
(TAIWAN,JAPAN)
HEATER WASH (1000W)
1 2 3
1 2 3
POWER CORD
~15A 125V
12A 125V
RELAY
3 4
3:P/CORD( ˆ»
4:W/HEATER( ˆ»
WF03:HEATER
1:
2:
3:
D/HEATER
W/HEATER
P-CORD(COMMON)
WF04:S/W POWER
2:
3:
RELAY 4
1
(WH)
3
1
BL BL BL
WF05:REACTOR
2:
1:
1 2 3
1 2 3
E1213R
4) DWD-E1221WT / DWD-E1223WT
E1213W
WF06
WF10:SENSOR WF09:MOTOR
BR
1 2 3 4 5
1 2 3 4 5
(WH)
6
6
7
7
8 9 10 11 12
8 9 10 11 12
GN YW PK GY WH VT BK
WF07
WF02:D/LOCK WF01:LOAD
(WH)
1 2
1 2
3
3
PK VT BL
MAIN PCB
(BL)
1 2
1 2
RD RD
1 2 3
(WH)
4 5 6 7 8
1 2 3 4 5 6 7 8
GN OR BL BK WH
1 2
1 2
ˆ»
(WH)
1 2
1 2
GY VT
(WH)
1 2 3
1 2 3
OR BR
(WH) CON.010-W/TH
1 2
GND Signal
1 2 3
Tm1
WATER
SENSOR
PRESSURE
Vdd1
U V
3 2
W
1
(WH)
CON.010-SH
Hb
Gnd
Ha
5V
SENSOR HALL
MOTOR MAIN(BLDC)
REACTOR
COLD PRE
VALVE INLET
WH
(WH) CON.010-B/P 1 2
1 2
BL
2
2
YK WR
BUBBLE PUMP MOTOR DRAIN
1
1
BK BL
2 3 4 5
S/W
DOOR LOCK
EARTH OUTER
(TAIWAN,JAPAN)
HEATER WASH (1000W)
48
RELAY
3 4
3:P/CORD(
ˆ»
4:W/HEATER( ˆ»
WF03:HEATER
1:
2: W/HEATER
3: ¥ P-CORD(COMMON)
WF04:S/W POWER
1: ˆ»
2: ß
3: ¥
4
1
(WH)
3
11
BLBL BLBL
WF05:REACTOR
2: ß
1: ß
1 2 3
1 2 3
1 2 3
1 2 3
POWER CORD
~15A 125V
12A 125V
8. TROUBLE SHOOTING REGARDING DRAIN
1. Drain Part Picture
HOSE DRAIN I
HOUSING VALVE
DRAIN MOTOR
VALVE AIR AS
2. Operating Sequence
DRAIN MOTOR connects drain passage by pulling LINK VALVE DRAIN. If the DRAIN MOTOR stops working,
LINK VALVE DRAIN returns to initial state by spring.
3. Check point when connecting hose drain O
① Keep the hose straight.
② Keep the end of hose not to dip in water.
4. Checking Methods
◎ Situation : * "OE" is shown on PCB.
* Not finishing drain during 10 min.
* The water level can not reach to RESET POINT during 10 min of drain.
Checking Methods
* Check the hose drain O condition; twisted or frozen.
Replacing methods
* replace HOSE DRAIN O
* clean the inside of COVER VALVE.
* Check the hose drain O condition, blocked.
* replace DRAIN MOTOR disassemble COVER
VALVE by turning and pulling
* DRAIN MOTOR is broken.
49
9. INSTALLATION GUIDE
1. PARTS & CONFIGURATION
PARTS NAME
FIXTURE UP/DOWN AS
UNIT SERVICE WRENCH
FIGURES
SPECIAL SCREW FIXTURE
UP DOWN
SPECIAL
SCREW
DOWN
REMARKS
SPECIAL SCREW UP
: L= 109mm
SPECIAL SCREW DOWN
:L=145mm
① Use this part to remove
FIXTURE UP/ DOWN.
② Adjust leg with this part.
LEG ADJUST AS
FIXTURE
LEG
FOOT
2. INSTALLATION PROCESS
① Remove the FIXTURE UP/DOWN AS
Removal Method Remarks
☞ Disassemble the FIXTURE UP/DOWN AS by turning CCW direction.
☞ Please keep FIXTURE UP/DOWN AS for later use.
☞ When fixing FIXTURE UP/DOWN AS, turn it CW direction.
② Insert CAP HOLDER(4EA) after removing FIXTURE UP/DOWN AS.
CAP HOLDER
50
③ Please install the DRUM WASHING MACHINE properly on even and hard floor as below.
④ Adjust the level of washer using LEG ADJUST AS.
Adjusting Method Remarks
☞ If turned CW, the LEG ADJUST AS moves the washer upward.
☞ If turned CCW, the LEG ADJUST AS moves the washer downward.
⑤ After adjusting level, fix SPECIAL BOLT.
Adjusting Method Remarks
☞ Please fix the SPECIAL BOLT by rotating it CCW in order to prevent washer vibration.
51
10. ATTENTION POINT WITH SERVICING
No Item Part Name
1 Replacing Thermistor Thermistor Dry
Dry
2 Replacing Duct B As DUCT B AS &
& Duct Pipe DUCT PIPE
Checking Point
Keep the Packing from seperating (Hold Packing when replacing)
Keep the Packing from folding
Check the sealing between Duct Pipe & Duct B AS
3 Replacing &
Repairing Inlet Valve
4 Replacing Hose Drain Hose Drain
5 Replacing HOSE
A,B,C
6 Replacing
Heater Wash
Inlet Valve
HOSE A,B,C
Use only screw M4*8 for fixing Inlet Valve
Keep the sealing condition of Tub O tightly
Check the assembling order between INLET BOX & Hose A,C :
Pre Wash-Cold
Unfastening the nut for fixing earth first then unfasten Heater Wash the nut for fixing heater
At assembling the heater dry, check if the assembling condition between fixture heater is tight.(little gap on left & right) At fastening the nut for fixing the heater wash, keep the protrusion length of bolt to 10~12mm.
“
“
“
7 Replacing
Thermistor Wash
Hinge Door ”
9 (Dis)assebling
Door AS ”
10 (Dis)assembling
“ Motor AS ”
”
(if under 10mm, water can leak, and if over 12mm, fixture heater can deform)
Thermistor Wash Unfasten the Nut for fixing heater, replace the thermistor, and fasten the nut for fixing heater
At fastening screw for fixing Door AS, be careful so that scratching at the related parts does not happen
: If the scratching happens, it is possible to be claimed about appearance damage
Door As Be careful about the up/down direction of Door Glass : Keep the indication point of the part code downward.
MOTOR AS To avoid the injury on the hand, grip the rim of the rotor
At initiating the assembling operation of the stator, grip the stator and fasten the screw; at unfastening the screw, grip the stator so that it does not fall.
52
본사:서울 마포구 아현동 686
소비자상담실: ( 대표 ) 360-8282 http://www.dwe.daewoo.co.kr
SVC GUIDE
DRUM WASHING MACHINE
DWD-E1211RT/DWD-E1211WT
DWD-E1221RT/DWD-E1221WT
DWD-E1223RT/DWD-E1223WT
advertisement
Related manuals
advertisement
Table of contents
- 7 1. WHAT IS DRUM?
- 11 2. SPECIFICATION OF DRUM WASHING MACHINE
- 12 3. VERIFICATION OF DRUM ASSY
- 13 4. PARTS LIST FOR EACH ASSY
- 25 5. SEQUENCE CHART OF PCB
- 33 6. SPECIFICATION OF ELECTRONIC PARTS
- 52 7. WIRING DIAGRAM
- 54 8. TROUBLESHOOTING REGARDING DRAIN
- 55 9. INSTALLATION GUIDE
- 57 10. ATTENTION POINT WITH SERVICE