Omron Varispeed V7 CIMR-V7TZB2P205 Brochure & Specs
Omron Varispeed V7 CIMR-V7TZB2P205 is a compact and powerful inverter drive designed for a wide range of industrial applications. With its advanced features like sensorless vector control, autotuning, and high-speed motion bus, it offers precise speed control, improved efficiency, and seamless integration into complex automation systems. The rugged IP65 enclosure allows for decentralized control, eliminating the need for additional cabinets and reducing installation costs.
विज्ञापन
विज्ञापन
NEW V7 INVERTERS
I m p r o v i n g o n p e r f e c t i o n
»
Decentralised control
»
Expanded functionality
» I n te l l i g e n c e o n b o a rd
Advanced Industrial Automation
Europe’s first choice - V7 inverters always meet your expectations
Since the V7 inverter was launched into the market,
Omron-Yaskawa has installed more than 1.5 million of V7 series inverters world-wide. It has become a market reference in reliability. The latter is not some quantifiable parameter that one can just mention in the specification sheet. It’s a rather rigorous process built into the genes of the product.
5%
3%
1%
1 year
Failure rate for drives
Market standard
Omron-Yaskawa
5 years
The secret of the leader is that it simply runs and runs until you tell it to stop…
The V7 is designed to operate in the most severe environments.
Hence, it goes far beyond normal expectations (standard published specifications). For example, it delivers 40% more current than any inverter on the market. And it does this under severe conditions, such as high carrier frequency, high temperature, large voltage fluctuations, etc. The result is that you get what’s in the box and much more.
Now that’s quality beyond a doubt!
10,00
8,00
6,00
4,00
2,00
0,00
Noisy operation
2,5 3
Conventional inverter vs V7 Amps Derating
400V - 4,0 Kw at 40ºC
Omron Yaskawa V7AZ
5 6
Conventional inverter
7,5
C.Frq. (KHz)
10
Silent operation
12 14
Robust IGBTs
T h e s e c r e t i n s i d e
Packaging feed
Positioning
Product feed
Product out
Rotating and static autotune
Besides the standard rotating autotune function, the new
V7 series also features static autotune. This greatly eases drive setup by eliminating the need to rotate the motor during autotuning. The result - faster, easier and cheaper installation and commissioning.
Position control at stop
Nominal speed
Speed
S >S S
Standard stop at nominal speed.
Unexpected stop position
Stopping without position control.
Stopping with position control.
Time
S: Travel distance
(blue area)
Preferred stop position
Embodying advanced on-board processing, V7 inverters offer unrivalled dynamic control, including fast braking and highprecision positioning at stop. From full speed to full stop is achieved faster than market standard inverters. Moreover, this braking performance is completely independent of the motor running speed, providing you with perfect control of your machines.
Advanced Industrial Automation
New features
• Sensor-less vector controller ensures 100% at 0.5Hz
• Compact size available in IP20 or IP65
• Silent operation
• Programming software:
CX-Drive for parameter configuration
• CASE (Inverter application software)
• PLC option board
• High speed Motion Bus: MECHATROLINK-II (ML-II)
• Connectivity: Memobus, Dnet, Profibus, CANopen
• New features:
- Autotuning
- Position control when stopping
- Carrier frequency up to 14KHz
- Analogue positioning
- Improved Up & Down function
- PTC input
- 2 Motors change function
- Free I/O’s setting to be used
from host controller
- Frequency Offsets
- New start / stop sequence
Cost-effective customisation with CASE
Special CASE (Customised Application Software) is available for the V7 series to provide customised control without need of any extra option boards. CASE gives standard inverters the performance of a custom-made solution, allowing big savings in hardware equipment and increasing system reliability.
Safe decentralised control
The V7 inverter is also available in a ruggedized IP65 housing, enabling you to decentralise your drive control without any extra cabinet costs. Operating independently of the main control panel, this solution also reduces cabling and saves on installation time.
PLC functionality
A PLC option board based on Omron’s market-leading PLC technology offers you all the cost-saving benefits of PLC functionality. It not only equips the V7 with extra functionality for a broad range of digital control tasks, it also leads to significant savings by eliminating the need for a separate PLC.
The board’s inverter-based architecture provides for wireless installation and seamless access to all V7 parameters. And it provides external communication via analogue/digital IOs.
MECHATROLINK-II
Using the Omron-Yaskawa MECHATROLINK-II digital motion bus, you can use the same high-speed motion bus throughout your machine, from motion controller, servo drives and now also the inverter. This creates a fully integrated system for the most advanced motion-control solutions.
CIMR-V7AZ
Varispeed V7
Sensorless vector in pocket size
• Nominal torque at 0.5 Hz
• Autotuning
• High carrier up to 14 khz
• Stop accuracy function.
• Integrated PID controller and bidirectional PID-out put
• Motor protection with PTC input
• Pulse input
• Standard digital operator with copy function
• Fieldbus: Modbus, DeviceNet, PROFIBUS, CANopen
• High speed motion bus: ML- II
• Plug-in PLC option unit. Total inverter access.
• CE, UL, and cUL marked
V7 IP65
• Compact size
• Easy wiring
• Built-in filter (Class B)
Customized software*
• The inverter software can be customized to meet specific application. Examples:
• Traverse sofware S-9381.
*For detailed information please refer to case software section.
Ratings
• 200 V Class single-phase 0.1 to 4 kW
• 200 V Class three-phase 0.1 to 7.5 kW
• 400 V Class three-phase 0.2 to 7.5 kW
System configuration
3G3IV-PCN329-E
Inverter to PC cable
CX-Drive 3G3IV-PEZZ8122_
DIN attachment
JVOP-144
Remote digital oper.
with potentiometer
JVOP-146
Remote digital oper.
with potentiometer
3G3IV-PCN126/326
Digital operator extension cable
*See note
Line filter Braking accessories
* V7 IP65 types are built-in filter inverters.
Varispeed
V7
Communication unit
*See note
PLC option unit
*See note
LKEB_ CDBR_B ERF150WJ_
* Option frames are needed for V7 IP65 type.
Specifications
Type designation
C I M R — V 7 A Z B 0 P 1 0
Inverter
V7 series
A: With digital operator (with potentiometer)
T: V7 IP65 type with digital operator
( without potentiometer )
Protective enclosure:
0: IP20
1: NEMA1
05: IP65
Max. applicable motor output
0P1: 0.1 kW
Z: European standard specifications
7P5: 7.5 kW
Voltage
B: Single-phase 200 VAC
2: Three-phase 200 VAC
4: Three-phase 400 VAC
200 V class
IP20 single-phase: CIMR-V7AZ
IP65 single-phase: CIMR-V7TZ
IP20 three-phase: CIMR-V7AZ
Maximum permissible motor output kW 1
Inverter capacity kVA
Rated output current A
Max. output voltage
Max. output frequency
B0P1
---
20P1
0.12
0.3
0.8
B0P2
---
20P2
0.25
0.6
1.6
B0P4
B0P405
20P4
0.55
1.1
3.0
B0P7
B0P705
20P7
1.1
1.9
5.0
B1P5
B1P505
21P5
1.5
3.0
8.0
Proportional to input voltage: 0..240 V
400 Hz
B2P2
B2P205
22P2
2.2
4.2
11.0
Rated input voltage and frequency
Allowable voltage fluctuation
Allowable frequency fluctuation
Single-phase 200..240 V 50/60 Hz
3-phase 200..230 V 50/60 Hz
-15%..+10%
+5%
1.
Based on a standard 4-pole motor for maximum applicable motor output. Select the inverter model within the allowable motor rated current
400 V class
IP20 three-phase: CIMR-V7AZ
IP65 three-phase: CIMR-V7TZ
Maximum permissible motor output kW 1
Inverter capacity kVA
Rated output current A
Max. output voltage
Max. output frequency
40P2
0.37
0.9
1.2
40P4 40P7 41P5 42P2 43P0 44P0
40P405 40P705 41P505 42P205 43P005 44P005
0.55
1.4
1.8
1.1
2.6
3.4
1.5
2.2
400 Hz
3.0
3.7
4.2
5.5
4.8
5.5
7.2
Proportional to input voltage: 0..400 V
4.0
7.0
9.2
45P5
5.5
11.0
14.8
Rated input voltage and frequency
Allowable voltage fluctuation
Allowable frequency fluctuation
3-phase 380..460 VAC, 50/60 Hz
-15%..+10%
+5%
1.
Based on a standard 4-pole motor for maximum applicable motor output. Select the inverter model within the allowable motor rated current
B4P0
---
24P0
4.0
6.7
17.5
47P5
7.5
14.0
18.0
Commom specifications
Model number
CIMR-V7AZ@
CIMR-V7TZ@
Control methods
Output frequency range
Frequency tolerance
Resolution of frequency set value
Resolution of output frequency
Overload capability
Frequency set value
Braking torque
(short term peak torque)
Binary inputs
Binary outputs
Analogue output
Analogue inputs
Braking/acceleration times
Display
Motor overload protection
Instantaneous overcurrent
Overload
Overvoltage
Undervoltage
Momentary power loss
Cooling fin overheat
Stall prevention level
Cooling fan fault
Ground fault
Power charge indication
Degree of protection
Cooling
Ambient temperature
Ambient humidity
Storage temperature
Installation
Installation height
Vibration
Specifications
Sine wave PWM (V/f control, sensorless vector control)
0.1..400 Hz
Digital set value: ±0.01% (-10..+50 ºC)
Analogue set value: ±0.5% (25 ±10 ºC)
Digital set value: 0.01 Hz (<100 Hz), 0.1 Hz (>100 Hz)
Analogue set value: 1/1000 of maximum frequency
0.01 Hz
150%/60 s
0..10 V (20 k Ω ), 4..20 mA (250 Ω ), 0..20 mA (250 Ω )
Pulse train input, frequency setting value (selectable)
Up to 200 W 150% or more
550 W to 1.1 kW 100% or more
1.5 kW 50% or more
>1.5 kW 20% or more
Continuous braking torque approx. 20% without, 150% with external braking resistor
7 freely programmable inputs
1 relay output, 2 freely programmable open collector outputs
1 programmable analogue output (0..10 V)/pulse output
2 analogue inputs, 0..10 V, 4..20 mA, 0..20 mA
0.01..6000 s
Optionally frequency, current or set value
Error and status LED
Electronic thermal overload relay
Motor coasts to a stop at approx. 250% of inverter rated current
Motor coasts to a stop after 1 minute at 150% of inverter rated output current
Motor coasts to a stop if DC bus voltage exceed 410 V (double for 400 V class)
Stops when DC bus voltage is approx. 200 V or less (double for 400 V class)
(approx. 160 V or less for single-phase series)
Following items are selectable: not provided (stop if power loss is 15 ms or longer), continuous operation if power loss is approx. 0.5 s or shorter, continuous operation
Protected by electronic circuit
Individual levels during accel/constant speed. Decel ON/OFF available. During decel enable/disable selectable.
Detected by electronic circuit (fan lock detection)
Protected by electronic circuit (operation level is approx. 250% of rated output current)
RUN lamp stays ON or digital operator LED stays ON until the DC bus voltage becomes 50 V or less.
(Charge LED is provided for 400 V)
IP20, NEMA1, IP65
Self cooling for 200 V 0.1..0.4 kW (3 or single phase) and for 400 V 0.2..0.75 kW
Cooling fan for 200 V 0.75 to 7.5 kW and for 400 V 1.5 to 7.5 kW
Open air mounting: -10 ºC..50 ºC
Wall mounting: -10 ºC..40 ºC
95% (without condensation)
-20 ºC..+60 ºC (short-term temperature during transportation)
Indoor (no corrosive gas, dust, etc.)
Max. 1000 m
10 to 20 Hz, 9.8 m/s 2 max; 20 to 50 Hz, 2 m/s 2 max
Varispeed V7
3
2
Specifications
Type designation
C I M R — V 7 A Z B 0 P 1 0
Inverter
V7 series
A: With digital operator (with potentiometer)
T: V7 IP65 type with digital operator
( without potentiometer )
Protective enclosure:
0: IP20
1: NEMA1
05: IP65
Max. applicable motor output
0P1: 0.1 kW
Z: European standard specifications
7P5: 7.5 kW
Voltage
B: Single-phase 200 VAC
2: Three-phase 200 VAC
4: Three-phase 400 VAC
200 V class
IP20 single-phase: CIMR-V7AZ
IP65 single-phase: CIMR-V7TZ
IP20 three-phase: CIMR-V7AZ
Maximum permissible motor output kW 1
Inverter capacity kVA
Rated output current A
Max. output voltage
Max. output frequency
B0P1
---
20P1
0.12
0.3
0.8
B0P2
---
20P2
0.25
0.6
1.6
B0P4
B0P405
20P4
0.55
1.1
3.0
B0P7
B0P705
20P7
1.1
1.9
5.0
B1P5
B1P505
21P5
1.5
3.0
8.0
Proportional to input voltage: 0..240 V
400 Hz
B2P2
B2P205
22P2
2.2
4.2
11.0
Rated input voltage and frequency
Allowable voltage fluctuation
Allowable frequency fluctuation
Single-phase 200..240 V 50/60 Hz
3-phase 200..230 V 50/60 Hz
-15%..+10%
+5%
1.
Based on a standard 4-pole motor for maximum applicable motor output. Select the inverter model within the allowable motor rated current
400 V class
IP20 three-phase: CIMR-V7AZ
IP65 three-phase: CIMR-V7TZ
Maximum permissible motor output kW 1
Inverter capacity kVA
Rated output current A
Max. output voltage
Max. output frequency
40P2
0.37
0.9
1.2
40P4 40P7 41P5 42P2 43P0 44P0
40P405 40P705 41P505 42P205 43P005 44P005
0.55
1.4
1.8
1.1
2.6
3.4
1.5
2.2
400 Hz
3.0
3.7
4.2
5.5
4.8
5.5
7.2
Proportional to input voltage: 0..400 V
4.0
7.0
9.2
45P5
5.5
11.0
14.8
Rated input voltage and frequency
Allowable voltage fluctuation
Allowable frequency fluctuation
3-phase 380..460 VAC, 50/60 Hz
-15%..+10%
+5%
1.
Based on a standard 4-pole motor for maximum applicable motor output. Select the inverter model within the allowable motor rated current
B4P0
---
24P0
4.0
6.7
17.5
47P5
7.5
14.0
18.0
Commom specifications
Model number
CIMR-V7AZ@
CIMR-V7TZ@
Control methods
Output frequency range
Frequency tolerance
Resolution of frequency set value
Resolution of output frequency
Overload capability
Frequency set value
Braking torque
(short term peak torque)
Binary inputs
Binary outputs
Analogue output
Analogue inputs
Braking/acceleration times
Display
Motor overload protection
Instantaneous overcurrent
Overload
Overvoltage
Undervoltage
Momentary power loss
Cooling fin overheat
Stall prevention level
Cooling fan fault
Ground fault
Power charge indication
Degree of protection
Cooling
Ambient temperature
Ambient humidity
Storage temperature
Installation
Installation height
Vibration
Specifications
Sine wave PWM (V/f control, sensorless vector control)
0.1..400 Hz
Digital set value: ±0.01% (-10..+50 ºC)
Analogue set value: ±0.5% (25 ±10 ºC)
Digital set value: 0.01 Hz (<100 Hz), 0.1 Hz (>100 Hz)
Analogue set value: 1/1000 of maximum frequency
0.01 Hz
150%/60 s
0..10 V (20 k Ω ), 4..20 mA (250 Ω ), 0..20 mA (250 Ω )
Pulse train input, frequency setting value (selectable)
Up to 200 W 150% or more
550 W to 1.1 kW 100% or more
1.5 kW 50% or more
>1.5 kW 20% or more
Continuous braking torque approx. 20% without, 150% with external braking resistor
7 freely programmable inputs
1 relay output, 2 freely programmable open collector outputs
1 programmable analogue output (0..10 V)/pulse output
2 analogue inputs, 0..10 V, 4..20 mA, 0..20 mA
0.01..6000 s
Optionally frequency, current or set value
Error and status LED
Electronic thermal overload relay
Motor coasts to a stop at approx. 250% of inverter rated current
Motor coasts to a stop after 1 minute at 150% of inverter rated output current
Motor coasts to a stop if DC bus voltage exceed 410 V (double for 400 V class)
Stops when DC bus voltage is approx. 200 V or less (double for 400 V class)
(approx. 160 V or less for single-phase series)
Following items are selectable: not provided (stop if power loss is 15 ms or longer), continuous operation if power loss is approx. 0.5 s or shorter, continuous operation
Protected by electronic circuit
Individual levels during accel/constant speed. Decel ON/OFF available. During decel enable/disable selectable.
Detected by electronic circuit (fan lock detection)
Protected by electronic circuit (operation level is approx. 250% of rated output current)
RUN lamp stays ON or digital operator LED stays ON until the DC bus voltage becomes 50 V or less.
(Charge LED is provided for 400 V)
IP20, NEMA1, IP65
Self cooling for 200 V 0.1..0.4 kW (3 or single phase) and for 400 V 0.2..0.75 kW
Cooling fan for 200 V 0.75 to 7.5 kW and for 400 V 1.5 to 7.5 kW
Open air mounting: -10 ºC..50 ºC
Wall mounting: -10 ºC..40 ºC
95% (without condensation)
-20 ºC..+60 ºC (short-term temperature during transportation)
Indoor (no corrosive gas, dust, etc.)
Max. 1000 m
10 to 20 Hz, 9.8 m/s 2 max; 20 to 50 Hz, 2 m/s 2 max
Frequency inverters
Digital operator
Data display
Indicators
(setting/monitor item indicators)
Operation keys
FREQUENCY adjuster
Appearance
Data display
Name
Frequency adjuster
Function
Displays relevant data items, such as frequency reference, output frequency, and parameter set values.
Sets the frequency reference within a range between 0 Hz and the maximum frequency. 1
Frequency reference indicator
Output frequency indicator
Output current indicator
Multi-function monitor indicator
Forward/reverse selection indicator
Local/remote selection indicator
Parameter setting indicator
Mode key
Increment key
Decrement key
Enter key
RUN key
The frequency reference can be monitored or set while this indicator is lit.
The output frequency of the inverter can be monitored while this indicator is lit.
The output current of the inverter can be monitored while this indicator is lit.
The values set in U01 through U10 are monitored while this indicator is lit.
The direction of rotation can be selected while this indicator is lit when operating the inverter with the RUN key.
The operation of the inverter through the digital operator or according to the set parameters is selectable while this indicator is lit. 2
The parameters in n001 through n179 can be set or monitored while this indicator is lit. 3
Switches the simplified-LED (setting and monitor) item indicators in sequence.
Parameter being set will be canceled if this key is pressed before entering the setting.
Increases multi-function monitor numbers, parameter numbers, and parameter set values.
Decreases multi-function monitor numbers, parameter numbers, and parameter set values.
Enters multi-function monitor numbers, parameter numbers, and internal data values after they are set or changed.
Starts the inverter running when the 3G3MV is in operation with the digital operator
STOP/RESET key Stops the inverter unless parameter n007 is set to disable the STOP key.
Used to reset the inverter when an error occurs. 4
1.
V7 IP65 types have digital operator without frequency adjuster.
2.
The status of the local/remote selection indicator can be only monitored while the inverter is in operation. Any RUN comand input is ignored while this indicator is lit.
3.
While inverter is in operation, the parameters can be only monitored and only some parameters can be changed. Any RUN command is ignored while the parameter setting indicator is lit.
4.
For safety reasons, the reset function cannot be used while an operation instruction (forward/reverse) is being input. Turn the operation instruction OFF before using this function.
Dimensions
IP 20 type 0.1 to 4 Kw
2 M4
4 M4
H 1 H H 1 H
W 1
W
8.5
(0.34)
Figure 1
D
D1
Voltage class
Three-phase
200 V
Single-phase
200 V
Three-phase
400 V
Max. applicable motor output kW
0.12
0.25
0.55
1.1
1.5
2.2
4.0
0.12
0.25
0.55
1.1
1.5
2.2
4.0
0.37
0.55
1.1
1.5
2.2
3.0
4.0
Inverter model
CIMR V7AZ
20P1
20P2
20P4
20P7
21P5
22P2
24P0
B0P1
B0P2
B0P4
B0P7
B1P5
B2P2
B4P0
40P2
40P4
40P7
41P5
42P2
43P0
44P0
Figure
1
2
1
2
2
IP20 / NEMA1 type 5.5/7.5 Kw
W
68
108
140
170
108
140
108
140
68
W 1
W
H
128
128
128
108
128
131
140
143
76
76
131
140
156
163
180
92
110
140
Dimensions in mm
D W1 H1
76
56
96
128
56
96
96
128
158
96
118
118
118
156
118
143 128
8.5
(0.34)
Figure 2
H2
5
5
5
5
5
D
D1
71
16
34
64
64
71
10
42
64
D1
10
42
62
71
Weight kg
0.6
0.6
0.9
1.1
1.4
1.5
2.1
0.6
0.7
1.0
1.5
1.5
2.2
2.9
1.0
1.1
1.5
1.5
1.5
2.1
2.1
Cooling method
Self cooled
Fan cooled
Self cooled
Fan cooled
Self cooled
Fan cooled
Voltage class
Three-phase
200 V
Three-phase
400 V
Max. applicable motor output kW
5.5
7.5
5.5
7.5
Inverter model
CIMR - V7AZ
25P5
27P5
45P5
47P5
Figure
3
W
180
180
Figure 3
H
260
Dimensions in mm (inches)
D W1 H1
170 164 244
H2
8
260 170 164 244 8
Varispeed V7
D1
65
65
Weight kg
4.6
4.8
4.8
4.8
Cooling method
Fan cooled
5
Digital operator
Data display
Indicators
(setting/monitor item indicators)
Operation keys
FREQUENCY adjuster
Appearance
Data display
Name
Frequency adjuster
Function
Displays relevant data items, such as frequency reference, output frequency, and parameter set values.
Sets the frequency reference within a range between 0 Hz and the maximum frequency. 1
Frequency reference indicator
Output frequency indicator
Output current indicator
Multi-function monitor indicator
Forward/reverse selection indicator
Local/remote selection indicator
Parameter setting indicator
Mode key
Increment key
Decrement key
Enter key
RUN key
The frequency reference can be monitored or set while this indicator is lit.
The output frequency of the inverter can be monitored while this indicator is lit.
The output current of the inverter can be monitored while this indicator is lit.
The values set in U01 through U10 are monitored while this indicator is lit.
The direction of rotation can be selected while this indicator is lit when operating the inverter with the RUN key.
The operation of the inverter through the digital operator or according to the set parameters is selectable while this indicator is lit. 2
The parameters in n001 through n179 can be set or monitored while this indicator is lit. 3
Switches the simplified-LED (setting and monitor) item indicators in sequence.
Parameter being set will be canceled if this key is pressed before entering the setting.
Increases multi-function monitor numbers, parameter numbers, and parameter set values.
Decreases multi-function monitor numbers, parameter numbers, and parameter set values.
Enters multi-function monitor numbers, parameter numbers, and internal data values after they are set or changed.
Starts the inverter running when the 3G3MV is in operation with the digital operator
STOP/RESET key Stops the inverter unless parameter n007 is set to disable the STOP key.
Used to reset the inverter when an error occurs. 4
1.
V7 IP65 types have digital operator without frequency adjuster.
2.
The status of the local/remote selection indicator can be only monitored while the inverter is in operation. Any RUN comand input is ignored while this indicator is lit.
3.
While inverter is in operation, the parameters can be only monitored and only some parameters can be changed. Any RUN command is ignored while the parameter setting indicator is lit.
4.
For safety reasons, the reset function cannot be used while an operation instruction (forward/reverse) is being input. Turn the operation instruction OFF before using this function.
Dimensions
IP 20 type 0.1 to 4 Kw
2 M4
4 M4
H 1 H H 1 H
W 1
W
8.5
(0.34)
Figure 1
D
D1
Voltage class
Three-phase
200 V
Single-phase
200 V
Three-phase
400 V
Max. applicable motor output kW
0.12
0.25
0.55
1.1
1.5
2.2
4.0
0.12
0.25
0.55
1.1
1.5
2.2
4.0
0.37
0.55
1.1
1.5
2.2
3.0
4.0
Inverter model
CIMR V7AZ
20P1
20P2
20P4
20P7
21P5
22P2
24P0
B0P1
B0P2
B0P4
B0P7
B1P5
B2P2
B4P0
40P2
40P4
40P7
41P5
42P2
43P0
44P0
Figure
1
2
1
2
2
IP20 / NEMA1 type 5.5/7.5 Kw
W
68
108
140
170
108
140
108
140
68
W 1
W
H
128
128
128
108
128
131
140
143
76
76
131
140
156
163
180
92
110
140
Dimensions in mm
D W1 H1
76
56
96
128
56
96
96
128
158
96
118
118
118
156
118
143 128
8.5
(0.34)
Figure 2
H2
5
5
5
5
5
D
D1
71
16
34
64
64
71
10
42
64
D1
10
42
62
71
Weight kg
0.6
0.6
0.9
1.1
1.4
1.5
2.1
0.6
0.7
1.0
1.5
1.5
2.2
2.9
1.0
1.1
1.5
1.5
1.5
2.1
2.1
Cooling method
Self cooled
Fan cooled
Self cooled
Fan cooled
Self cooled
Fan cooled
Voltage class
Three-phase
200 V
Three-phase
400 V
Max. applicable motor output kW
5.5
7.5
5.5
7.5
Inverter model
CIMR - V7AZ
25P5
27P5
45P5
47P5
Figure
3
W
180
180
Figure 3
H
260
Dimensions in mm (inches)
D W1 H1
170 164 244
H2
8
260 170 164 244 8
D1
65
65
Weight kg
4.6
4.8
4.8
4.8
Cooling method
Fan cooled
Frequency inverters
4
IIP65 type 0.55 to 4 Kw
W 2
D
D1
W
W 1
6 . 4
H
H 1
IP65 type 0.55 to 4Kw (with option frame accessory attached)
W 2
D2
D
D1
W
W 1
6 . 4
H
H 1
3x PG25
Figure 4
Voltage class
Single-phase
200 V
Three-phase
400 V
Max. applicable motor output kW
0.55
1.1
1.5
2.2
0.55
1.1
1.5
2.2
3.0
4.0
Inverter model
CIMR V7TZ
B0P405
B0P705
B1P505
B2P205
40P405
40P705
41P505
42P205
43P005
44P005
Figure
4
W
280
280
H D
240 142
240 142
Dimensions in mm
W1
260
260
W2
228
228
H1
165
165
H2
38
38
H3
275
275
D1
44
44
Weight kg
Cooling method
Self cooled
3.7
3.7
4.1
4.1
3.4
4.3
3.7
4.2
4.2
4.3
Fan cooled
Self cooled
Fan cooled
2x PG12 3x PG25 Figure 5
Voltage class
Singlephase 200 V
Three-phase
400 V
Max. applicable motor output kW
0.55
1.1
1.5
2.2
0.55
1.1
1.5
2.2
3.0
4.0
Inverter model
CIMR V7TZ
Figure
B0P405
B0P705
B1P505
B2P205
40P405
40P705
41P505
42P205
43P005
44P005
5
W
280
280
H
240 180
240
D
180
W1
260 228 165 38 275
260
Dimensions in mm
W2 H1
228 165
H2
38
H3
275
D1
44
44
D2
38
38
Weight kg
Cooling method
Self cooled
4.5
3.9
3.9
4.3
4.3
3.6
4.5
3.9
4.4
4.4
Fan cooled
Self cooled
Fan cooled
Varispeed V7
7
IIP65 type 0.55 to 4 Kw
W 2
D
D1
W
W 1
6 . 4
H
H 1
IP65 type 0.55 to 4Kw (with option frame accessory attached)
W 2
D2
D
D1
W
W 1
6 . 4
H
H 1
3x PG25
Figure 4
Voltage class
Single-phase
200 V
Three-phase
400 V
Max. applicable motor output kW
0.55
1.1
1.5
2.2
0.55
1.1
1.5
2.2
3.0
4.0
Inverter model
CIMR V7TZ
B0P405
B0P705
B1P505
B2P205
40P405
40P705
41P505
42P205
43P005
44P005
Figure
4
W
280
280
H D
240 142
240 142
Dimensions in mm
W1
260
260
W2
228
228
H1
165
165
H2
38
38
H3
275
275
D1
44
44
Weight kg
Cooling method
Self cooled
3.7
3.7
4.1
4.1
3.4
4.3
3.7
4.2
4.2
4.3
Fan cooled
Self cooled
Fan cooled
2x PG12 3x PG25 Figure 5
Voltage class
Singlephase 200 V
Three-phase
400 V
Max. applicable motor output kW
0.55
1.1
1.5
2.2
0.55
1.1
1.5
2.2
3.0
4.0
Inverter model
CIMR V7TZ
Figure
B0P405
B0P705
B1P505
B2P205
40P405
40P705
41P505
42P205
43P005
44P005
5
W
280
280
H
240 180
240
D
180
W1
260 228 165 38 275
260
Dimensions in mm
W2 H1
228 165
H2
38
H3
275
D1
44
44
D2
38
38
Weight kg
Cooling method
Self cooled
4.5
3.9
3.9
4.3
4.3
3.6
4.5
3.9
4.4
4.4
Fan cooled
Self cooled
Fan cooled
Frequency inverters
6
Installation
Standard connections
MCCB
R
S
T
Multifunction input
Forward run/stop
Reverse run/stop
External fault
(no contact)
Fault reset
Multi-step speed reference 1
Multi-step speed reference 2
JOG command
Frequency reference
Pulse train input
2k Ω
Frequency setter
P P
MEMOBUS communication
RS-485/422 max 19.2kBPS
Line filter
1*
S5
S6
S7
S1
S2
S3
S4
SC
DC reactor (option)
U
Short bar
X
+2
R/L1
S/L2
T/L3
+1 –
Thermal overload relay (option)
B1
Braking resistor
(option)
B2
U/T1
V/T2
NPN
PHC
PHC
PHC
PNP
PHC
PHC
PHC
PHC
24 V
W/T3
MA
MB
MC
P1
Fault
Running
Grounding
Multi-function output
250 VAC 1 A or less
30 VDC 1 A or less
IM
R+
R–
S+
S–
Shield connection terminal
RP
Speed reference pulse train
FS
FR
FC
(33 kHz max.)
Frequency setting power supply
(+12 V 20 mA)
Speed frequency reference
0 to +10 V (20 k
4 to 20 mA (250
Ω ) OR
)
0 V
Digital operator frequency setting potentiometer min
P2
PC max
CN2
VIN
IIN
GND
Speed agree
Multi-function photocoupler output
+48 VDC 50 mA or less
Housing (type : ZHR-3)
0 to 10 V
P 4 to 20 mA
0V
Multi-function analog input 2*
Terminal resistance
(1/2 W. 120 Ω )
AM
AC
Frequency meter adjusting potentiometer
P
Output frequency
FM
Analog monitor output
0 TO +10 VDC (2 mA)
Pulse monitor output
(12 VDC
20 mA max. 30 - 70% duty)
1*
V7 IP65 types are built-in filter.
2* A housing is required when using the CN2 terminal on the back side of the digital operator.
1m analog input cable (code no. 3G3MV-PCN-CN2) is available for housing on request
: shielded wire P : twisted pair shielded wire
Shows the following two kinds of connections (factory setting) :
· Input signals (S1 to S7) are non-voltage contacts
· Sequence connection by NPN transistor (0V common)
A +24 V power supply is required for sequence connection by PNP transistor (+24 V common) .
Main circuit
Terminal
R/L1, S/L2, T/L3
U/T1, V/T2, W/T3
B1, B2
+2, +1
+1, –
Name
AC power supply input
Inverter output
Braking resistor connection
DC reactor connection
DC power supply input
Grounding
Function (signal level)
Main circuit power supply input (use R/L1 and S/L2 for single-phase power supply inverter.
Do not use T/L3 of the models less than 0.75 kW for other usage, such as a junction terminal.)
For inverter output
For braking resistor connection
Remove the short bar between +2 and +1 when connecting DC reactor (option)
For power supply input (+1: positive electrode; – : negative electrode)*
For grounding (grounding should conform to the local grounding code.)
Control Circuit
Type
S4
S5
S6
S7
No.
S1
S2
S3
SC
RP
FS
FR
FC
1 (CN2)
2 (CN2)
3 (CN2
MA
NC
MC
P1
P2
PC
AM
AC
R+
R–
S+
S–
Signal name
Multi-function input selection 1
Multi-function input selection 2
Multi-function input selection 3
Function
Factory setting: runs when CLOSED, stops when OPEN.
Factory setting: runs when CLOSED, stops when OPEN.
Factory setting: "fault reset"
Signal level
Multi-function input selection 4
Multi-function input selection 5
Factory setting: "external fault (NO contact)"
Factory setting: "multi-step speed reference 1"
24VDC, 8mA photocoupler insulation
Multi-function input selection 6 Factory setting: "multi-step speed reference 2"
Multi-function input selection 7
Multi-function input selection
Common
Speed reference pulse train input
Power supply terminal for frequency setting
Speed frequency reference
Factory setting: "JOG command"
Common for control signal
33 kHz max.
+12V (allowable current: 20 mA max.)
0 to +10 VDC (20 k Ω ) or 4 to 20 mA (250 Ω ), 0 to 20 mA (250 Ω ) (resolution 1/1000)
Frequency reference common 0 V
Multi-function analog voltage input Voltage input (between terminals 1 and 3): 0 to 10 VDC (input impedance: 20 k Ω )
Multi-function analog current input
Current input (between terminals 2 and 3): 4 to 20 mA (input impedance: 250 Ω )
Multi-function analog input common
NO contact output
Contact output
Contact output common
Factory setting: "fault"
Photocoupler output 1
Photocoupler output 2
Photocoupler output common
Analog monitor output
Factory setting: "running"
Factory setting: "at frequency"
0 V
Factory setting: "output frequency" 0 to +10 V output
(pulse monitor output available by setting constants. Duty: 30 to 70%)
0 V Analog monitor common
Communication input (+)
Communication input (–)
Communication output (+)
Communication output (–)
For MEMOBUS communication operation by RS-485 or RS-422 communication is available.
Contact capacity
250 VAC,
1 A or less
30 VDC, 1 A or less
Photocoupler output:
+48 VDC, 50 mA or less
0 to 10 V 2 mA or less
Resolution: 8 bits
RS-485/422
MEMOBUS protocol
19.2 kBPS max.
Varispeed V7
13
Installation
Standard connections
MCCB
R
S
T
Multifunction input
Forward run/stop
Reverse run/stop
External fault
(no contact)
Fault reset
Multi-step speed reference 1
Multi-step speed reference 2
JOG command
Frequency reference
Pulse train input
2k Ω
Frequency setter
P P
MEMOBUS communication
RS-485/422 max 19.2kBPS
Line filter
1*
S5
S6
S7
S1
S2
S3
S4
SC
DC reactor (option)
U
Short bar
X
+2
R/L1
S/L2
T/L3
+1 –
Thermal overload relay (option)
B1
Braking resistor
(option)
B2
U/T1
V/T2
NPN
PHC
PHC
PHC
PNP
PHC
PHC
PHC
PHC
24 V
W/T3
MA
MB
MC
P1
Fault
Running
Grounding
Multi-function output
250 VAC 1 A or less
30 VDC 1 A or less
IM
R+
R–
S+
S–
Shield connection terminal
RP
Speed reference pulse train
FS
FR
FC
(33 kHz max.)
Frequency setting power supply
(+12 V 20 mA)
Speed frequency reference
0 to +10 V (20 k
4 to 20 mA (250
Ω ) OR
)
0 V
Digital operator frequency setting potentiometer min
P2
PC max
CN2
VIN
IIN
GND
Speed agree
Multi-function photocoupler output
+48 VDC 50 mA or less
Housing (type : ZHR-3)
0 to 10 V
P 4 to 20 mA
0V
Multi-function analog input 2*
Terminal resistance
(1/2 W. 120 Ω )
AM
AC
Frequency meter adjusting potentiometer
P
Output frequency
FM
Analog monitor output
0 TO +10 VDC (2 mA)
Pulse monitor output
(12 VDC
20 mA max. 30 - 70% duty)
1*
V7 IP65 types are built-in filter.
2* A housing is required when using the CN2 terminal on the back side of the digital operator.
1m analog input cable (code no. 3G3MV-PCN-CN2) is available for housing on request
: shielded wire P : twisted pair shielded wire
Shows the following two kinds of connections (factory setting) :
· Input signals (S1 to S7) are non-voltage contacts
· Sequence connection by NPN transistor (0V common)
A +24 V power supply is required for sequence connection by PNP transistor (+24 V common) .
Frequency inverters
12
Main circuit
Terminal
R/L1, S/L2, T/L3
U/T1, V/T2, W/T3
B1, B2
+2, +1
+1, –
Name
AC power supply input
Inverter output
Braking resistor connection
DC reactor connection
DC power supply input
Grounding
Function (signal level)
Main circuit power supply input (use R/L1 and S/L2 for single-phase power supply inverter.
Do not use T/L3 of the models less than 0.75 kW for other usage, such as a junction terminal.)
For inverter output
For braking resistor connection
Remove the short bar between +2 and +1 when connecting DC reactor (option)
For power supply input (+1: positive electrode; – : negative electrode)*
For grounding (grounding should conform to the local grounding code.)
Control Circuit
Type
S4
S5
S6
S7
No.
S1
S2
S3
SC
RP
FS
FR
FC
1 (CN2)
2 (CN2)
3 (CN2
MA
NC
MC
P1
P2
PC
AM
AC
R+
R–
S+
S–
Signal name
Multi-function input selection 1
Multi-function input selection 2
Multi-function input selection 3
Function
Factory setting: runs when CLOSED, stops when OPEN.
Factory setting: runs when CLOSED, stops when OPEN.
Factory setting: "fault reset"
Signal level
Multi-function input selection 4
Multi-function input selection 5
Factory setting: "external fault (NO contact)"
Factory setting: "multi-step speed reference 1"
24VDC, 8mA photocoupler insulation
Multi-function input selection 6 Factory setting: "multi-step speed reference 2"
Multi-function input selection 7
Multi-function input selection
Common
Speed reference pulse train input
Power supply terminal for frequency setting
Speed frequency reference
Factory setting: "JOG command"
Common for control signal
33 kHz max.
+12V (allowable current: 20 mA max.)
0 to +10 VDC (20 k Ω ) or 4 to 20 mA (250 Ω ), 0 to 20 mA (250 Ω ) (resolution 1/1000)
Frequency reference common 0 V
Multi-function analog voltage input Voltage input (between terminals 1 and 3): 0 to 10 VDC (input impedance: 20 k Ω )
Multi-function analog current input
Current input (between terminals 2 and 3): 4 to 20 mA (input impedance: 250 Ω )
Multi-function analog input common
NO contact output
Contact output
Contact output common
Factory setting: "fault"
Photocoupler output 1
Photocoupler output 2
Photocoupler output common
Analog monitor output
Factory setting: "running"
Factory setting: "at frequency"
0 V
Factory setting: "output frequency" 0 to +10 V output
(pulse monitor output available by setting constants. Duty: 30 to 70%)
0 V Analog monitor common
Communication input (+)
Communication input (–)
Communication output (+)
Communication output (–)
For MEMOBUS communication operation by RS-485 or RS-422 communication is available.
Contact capacity
250 VAC,
1 A or less
30 VDC, 1 A or less
Photocoupler output:
+48 VDC, 50 mA or less
0 to 10 V 2 mA or less
Resolution: 8 bits
RS-485/422
MEMOBUS protocol
19.2 kBPS max.
W = 30 mm min. (0.1 to 4.0 KW)
50 mm min. (5.5 and 7.5 KW)
Inverter Inverter Inverter
100 mm min.
Air
Side
100 mm min.
Air
Inverter heat loss
Three-phase 200 V class
Model CIMR-V7AZ
Inverter capacity kVA
Rated current A
Fin
Inside unit
Total heat loss
20P1
0.3
0.8
3.7
9.3
13.0
20P2
0.6
1.6
7.7
10.3
18.0
20P4
1.1
3
15.8
12.3
28.1
20P7
1.9
5
28.4
16.7
45.1
21P5
3.0
8
53.7
19.1
72.8
22P2
4.2
11
60.4
34.4
94.8
Single-phase 200 V class
Model CIMR-V7AZ
Inverter capacity kVA
Rated current A
Fin
Inside unit
Total heat loss
Three-phase 400 V class
Model CIMR-V7AZ
Inverter capacity kVA
Rated current A
Fin
Inside unit
Total heat loss
B0P1
0.3
0.8
3.7
10.4
14.1
40P2
1.4
1.8
15.1
15.0
30.1
B0P2
0.6
1.6
7.7
12.3
20.0
40P4
2.6
3.4
30.3
24.6
54.9
B0P4
1.1
3
15.8
16.1
31.9
40P7
3.7
4.8
45.8
29.9
75.7
B0P7
1.9
5
28.4
23.0
51.4
41P5
4.2
5.5
50.5
32.5
83.0
B1P5
3.0
8
53.7
29.1
82.8
42P2
5.5
7.2
58.2
37.6
95.8
B2P2
4.2
11
64.5
49.1
113.6
44P0
7.0
8.6
73.4
44.5
117.9
Installation conditions for IP65
Install the inverter vertically in order to ensure proper cooling. When installing the inverter, always provide the following minimum installation space to allow normal heat dissipation.
45P5
11
14.8
168.8
87.7
256.5
B4P0
6.7
17.5
98.2
78.2
176.4
24P0
6.7
17.5
96.7
52.4
149.1
50 mm or more
120 mm or more
Air
47P5
14
18
209.6
99.3
308.9
25P5
9.5
25
170.4
79.4
249.8
27P5
13
33
219.2
98.9
318.1
40 mm or more
50 mm or more
40 mm or more
120 mm or more
Air
Side spaces Top and bottom spaces
1. Always provide enough space for the main circuit or control lines including cable gland.
2. If installing inverters next to one another, provide a minimum spacing of 60mm .
Ordering information
3G3IV-PCN329-E
Inverter to PC cable
CX-Drive
D
Line filter
D
*See note
3G3IV-PEZZ8122_
DIN attachment
JVOP-144
Remote digital oper.
with potentiometer
JVOP-146
Remote digital oper.
with potentiometer
3G3IV-PCN126/326
Digital operator extension cable
D D D D
Braking accessories
A
* V7 IP65 types are built-in filter inverters.
Varispeed
V7
Communication unit
*See note
PLC option unit
*See note
B C
* Option frames are needed for V7 IP65 type.
E
LKEB_ CDBR_B ERF150WJ_
Varispeed V7
200 V
1x200 V
3x200 V
Specifications
0.12 Kw
0.25 Kw
0.55 Kw
1.1 Kw
1.5 Kw
2.2 Kw
4.0 Kw
0.12 Kw
0.25 Kw
0.55 Kw
1.1 Kw
1.5 Kw
2.2 Kw
4.0 Kw
5.5 Kw
7.5 Kw
0.8 A
1.6 A
3.0 A
5.0 A
8.0 A
11.0 A
17.5 A
0.8 A
1.6 A
3.0 A
5.0 A
8.0 A
11.0 A
17.5 A
25.0 A
33.0 A
Varispeed V7
Model
CIMR-V7AZB0P10
CIMR-V7AZB0P20
CIMR-V7AZB0P40
CIMR-V7AZB0P70
CIMR-V7AZB1P50
CIMR-V7AZB2P20
CIMR-V7AZB4P00
CIMR-V7AZ20P10
CIMR-V7AZ20P20
CIMR-V7AZ20P40
CIMR-V7AZ20P70
CIMR-V7AZ21P50
CIMR-V7AZ22P20
CIMR-V7AZ24P00
CIMR-V7AZ25P51
CIMR-V7AZ27P51
400 V
3x400 V
Specifications
0.37 Kw
0.55 Kw
1.1 Kw
1.5 Kw
2.2 Kw
3.0 Kw
4.0 Kw
5.5 Kw
7.5 Kw
1.2 A
1.8 A
3.4 A
4.8 A
5.5 A
7.2 A
9.2 A
14.8 A
18.0 A
Model
CIMR-V7AZ40P20
CIMR-V7AZ40P40
CIMR-V7AZ40P70
CIMR-V7AZ41P50
CIMR-V7AZ42P20
CIMR-V7AZ43P00
CIMR-V7AZ44P00
CIMR-V7AZ45P51
CIMR-V7AZ47P51
17
W = 30 mm min. (0.1 to 4.0 KW)
50 mm min. (5.5 and 7.5 KW)
Inverter Inverter Inverter
100 mm min.
Air
Side
100 mm min.
Air
Inverter heat loss
Three-phase 200 V class
Model CIMR-V7AZ
Inverter capacity kVA
Rated current A
Fin
Inside unit
Total heat loss
20P1
0.3
0.8
3.7
9.3
13.0
20P2
0.6
1.6
7.7
10.3
18.0
20P4
1.1
3
15.8
12.3
28.1
20P7
1.9
5
28.4
16.7
45.1
21P5
3.0
8
53.7
19.1
72.8
22P2
4.2
11
60.4
34.4
94.8
Single-phase 200 V class
Model CIMR-V7AZ
Inverter capacity kVA
Rated current A
Fin
Inside unit
Total heat loss
Three-phase 400 V class
Model CIMR-V7AZ
Inverter capacity kVA
Rated current A
Fin
Inside unit
Total heat loss
B0P1
0.3
0.8
3.7
10.4
14.1
40P2
1.4
1.8
15.1
15.0
30.1
B0P2
0.6
1.6
7.7
12.3
20.0
40P4
2.6
3.4
30.3
24.6
54.9
B0P4
1.1
3
15.8
16.1
31.9
40P7
3.7
4.8
45.8
29.9
75.7
B0P7
1.9
5
28.4
23.0
51.4
41P5
4.2
5.5
50.5
32.5
83.0
B1P5
3.0
8
53.7
29.1
82.8
42P2
5.5
7.2
58.2
37.6
95.8
B2P2
4.2
11
64.5
49.1
113.6
44P0
7.0
8.6
73.4
44.5
117.9
Installation conditions for IP65
Install the inverter vertically in order to ensure proper cooling. When installing the inverter, always provide the following minimum installation space to allow normal heat dissipation.
45P5
11
14.8
168.8
87.7
256.5
B4P0
6.7
17.5
98.2
78.2
176.4
24P0
6.7
17.5
96.7
52.4
149.1
50 mm or more
120 mm or more
Air
47P5
14
18
209.6
99.3
308.9
25P5
9.5
25
170.4
79.4
249.8
27P5
13
33
219.2
98.9
318.1
Ordering information
3G3IV-PCN329-E
Inverter to PC cable
CX-Drive
D
Line filter
D
*See note
3G3IV-PEZZ8122_
DIN attachment
JVOP-144
Remote digital oper.
with potentiometer
JVOP-146
Remote digital oper.
with potentiometer
3G3IV-PCN126/326
Digital operator extension cable
D D D D
Braking accessories
A
* V7 IP65 types are built-in filter inverters.
Varispeed
V7
Communication unit
*See note
PLC option unit
*See note
B C
* Option frames are needed for V7 IP65 type.
E
LKEB_ CDBR_B ERF150WJ_
Varispeed V7
14
40 mm or more
50 mm or more
40 mm or more
120 mm or more
Air
Side spaces Top and bottom spaces
1. Always provide enough space for the main circuit or control lines including cable gland.
2. If installing inverters next to one another, provide a minimum spacing of 60mm .
Frequency inverters
200 V
1x200 V
3x200 V
Specifications
0.12 Kw
0.25 Kw
0.55 Kw
1.1 Kw
1.5 Kw
2.2 Kw
4.0 Kw
0.12 Kw
0.25 Kw
0.55 Kw
1.1 Kw
1.5 Kw
2.2 Kw
4.0 Kw
5.5 Kw
7.5 Kw
0.8 A
1.6 A
3.0 A
5.0 A
8.0 A
11.0 A
17.5 A
0.8 A
1.6 A
3.0 A
5.0 A
8.0 A
11.0 A
17.5 A
25.0 A
33.0 A
Model
CIMR-V7AZB0P10
CIMR-V7AZB0P20
CIMR-V7AZB0P40
CIMR-V7AZB0P70
CIMR-V7AZB1P50
CIMR-V7AZB2P20
CIMR-V7AZB4P00
CIMR-V7AZ20P10
CIMR-V7AZ20P20
CIMR-V7AZ20P40
CIMR-V7AZ20P70
CIMR-V7AZ21P50
CIMR-V7AZ22P20
CIMR-V7AZ24P00
CIMR-V7AZ25P51
CIMR-V7AZ27P51
400 V
3x400 V
Specifications
0.37 Kw
0.55 Kw
1.1 Kw
1.5 Kw
2.2 Kw
3.0 Kw
4.0 Kw
5.5 Kw
7.5 Kw
1.2 A
1.8 A
3.4 A
4.8 A
5.5 A
7.2 A
9.2 A
14.8 A
18.0 A
Model
CIMR-V7AZ40P20
CIMR-V7AZ40P40
CIMR-V7AZ40P70
CIMR-V7AZ41P50
CIMR-V7AZ42P20
CIMR-V7AZ43P00
CIMR-V7AZ44P00
CIMR-V7AZ45P51
CIMR-V7AZ47P51
Varispeed V7 IP65
200 V
1x200 V
Specifications
0.55 Kw
1.1 Kw
1.5 Kw
2.2 Kw
3.0 A
5.0 A
8.0 A
11.0 A
A Line filters *
Model
CIMR-V7TZB0P405
CIMR-V7TZB0P705
CIMR-V7TZB1P505
CIMR-V7TZB2P205
400 V
3x400 V
Specifications
0.55 Kw
1.1 Kw
1.5 Kw
2.2 Kw
3.0 Kw
4.0 Kw
1.8 A
3.4 A
4.8 A
5.5 A
7.2 A
9.2 A
Model
CIMR-V7TZ40P405
CIMR-V7TZ40P705
CIMR-V7TZ41P505
CIMR-V7TZ42P205
CIMR-V7TZ43P005
CIMR-V7TZ44P005
Voltage
3-Phase 200 VAC
Single-Phase 200 VAC
3-Phase 400 VAC
Inverter
Model CIMR-V7AZ
20P1 / 20P2 / 20P4 / 20P7
21P5 / 22P2
24P0
25P5 / 27P5
B0P1 / B0P2 / B0P4
B0P7 / B1P5
B2P2
B4P0
40P2 / 40P4
40P7 / 41P5 / 42P2
40P4
45P5 / 47P5
* V7 IP65 types are built-in filter inverters.
Schaffner
3G3MV-PFI2010-SE
3G3MV-PFI2020-SE
3G3MV-PFI2030-SE
-
3G3MV-PFI1010-SE
3G3MV-PFI1020-SE
3G3MV-PFI1030-SE
3G3MV-PFI1040-SE
3G3MV-PFI3005-SE
3G3MV-PFI3010-SE
3G3MV-PFI3020-SE
3G3MV-PFI3030-SE
Line filter
Rasmi
3G3MV-PFI2010-E
3G3MV-PFI2020-E
3G3MV-PFI2030-E
3G3MV-PFI2050-E
3G3MV-PFI1010-E
3G3MV-PFI1020-E
3G3MV-PFI1030-E
3G3MV-PFI1040-E
3G3MV-PFI3005-E
3G3MV-PFI3010-E
3G3MV-PFI3020-E
3G3MV-PFI3030-E
Rated current (A)
10
20
30
50
40
5
10
15
30
10
20
30
Weight (kg)
0.8
1.0
1.1
2.3
0.6
1.0
1.1
1.2
1.0
1.0
1.1
2.3
B
Communication cards
Type Model 1
3G3MV-PDRT2
Description
DeviceNet option card 2
Function
• Used for running or stopping the inverter, setting or referencing parameters, and monitoring output frequency, output current, or similar items through DeviceNet communication with the host controller.
SI-P1/V7
PROFIBUS-DP option card
• Used for running or stopping the inverter, setting or referencing parameters, and monitoring output frequency, output current, or similar items through PROFIBUS-DP communication with the host controller.
SI-S1/V7
Can open option card
• Used for running or stopping the inverter, setting or referencing parameters, and monitoring output frequency, output current, or similar items through CANopen communication with the host controller.
3G3MV-PCORT21
Can open gateway
• Used for running or stopping the inverter, setting or referencing parameters, and monitoring output frequency, output current, or similar items through CANopen communication with the host controller.
SI-T1/V7
MECHATROLINK-II option card
• Used for running or stopping the inverter, setting or referencing parameters, and monitoring output frequency, output current, or similar items through MECHATROLINK-II communication with the host controller.
• High speed motion bus.
• Host controller: TrajeXia, MCH or MP series.
3
1.
Option frame accessory is needed for V7 IP65 types when communications option units are used.
2.
For V7 IP65 types with DeviceNet communication, SI-N1/V7 should be used.
3.
Please refer to TrajeXia, MCH or MP series section for host controller technical information.
C PLC option card
Type Model 1
3G3MV-P10CDT-E
Description
PLC option
Function
• Full PLC featrues, wireless installation and seamless access to the inverter parameters and analogue/digital inputs and outputs.
• Standard OMRON tools can be used for programming
• Calendar / clock
• Same features as standard models with RS 422/485 support.
PLC option with
RS 422/485
3G3MV-P10CDT3-E
1.
Option frame accessory is needed on V7 IP65 types when PLC option unit is used.
D
Option frame accessory for V7 IP65
Type Model Description
V7TZ-FR1
Function
• Frame accessory is needed when communication option unit or PLC option unit are used with Varispeed V7 IP65.
Option frame
Varispeed V7
19
Varispeed V7 IP65
200 V
1x200 V
Specifications
0.55 Kw
1.1 Kw
1.5 Kw
2.2 Kw
3.0 A
5.0 A
8.0 A
11.0 A
A Line filters *
Model
CIMR-V7TZB0P405
CIMR-V7TZB0P705
CIMR-V7TZB1P505
CIMR-V7TZB2P205
400 V
3x400 V
Specifications
0.55 Kw
1.1 Kw
1.5 Kw
2.2 Kw
3.0 Kw
4.0 Kw
1.8 A
3.4 A
4.8 A
5.5 A
7.2 A
9.2 A
Model
CIMR-V7TZ40P405
CIMR-V7TZ40P705
CIMR-V7TZ41P505
CIMR-V7TZ42P205
CIMR-V7TZ43P005
CIMR-V7TZ44P005
Voltage
3-Phase 200 VAC
Single-Phase 200 VAC
3-Phase 400 VAC
Inverter
Model CIMR-V7AZ
20P1 / 20P2 / 20P4 / 20P7
21P5 / 22P2
24P0
25P5 / 27P5
B0P1 / B0P2 / B0P4
B0P7 / B1P5
B2P2
B4P0
40P2 / 40P4
40P7 / 41P5 / 42P2
40P4
45P5 / 47P5
* V7 IP65 types are built-in filter inverters.
Schaffner
3G3MV-PFI2010-SE
3G3MV-PFI2020-SE
3G3MV-PFI2030-SE
-
3G3MV-PFI1010-SE
3G3MV-PFI1020-SE
3G3MV-PFI1030-SE
3G3MV-PFI1040-SE
3G3MV-PFI3005-SE
3G3MV-PFI3010-SE
3G3MV-PFI3020-SE
3G3MV-PFI3030-SE
Line filter
Rasmi
3G3MV-PFI2010-E
3G3MV-PFI2020-E
3G3MV-PFI2030-E
3G3MV-PFI2050-E
3G3MV-PFI1010-E
3G3MV-PFI1020-E
3G3MV-PFI1030-E
3G3MV-PFI1040-E
3G3MV-PFI3005-E
3G3MV-PFI3010-E
3G3MV-PFI3020-E
3G3MV-PFI3030-E
Rated current (A)
10
20
30
50
40
5
10
15
30
10
20
30
Weight (kg)
0.8
1.0
1.1
2.3
0.6
1.0
1.1
1.2
1.0
1.0
1.1
2.3
B
Communication cards
Type Model 1
3G3MV-PDRT2
Description
DeviceNet option card 2
Function
• Used for running or stopping the inverter, setting or referencing parameters, and monitoring output frequency, output current, or similar items through DeviceNet communication with the host controller.
SI-P1/V7
PROFIBUS-DP option card
• Used for running or stopping the inverter, setting or referencing parameters, and monitoring output frequency, output current, or similar items through PROFIBUS-DP communication with the host controller.
SI-S1/V7
Can open option card
• Used for running or stopping the inverter, setting or referencing parameters, and monitoring output frequency, output current, or similar items through CANopen communication with the host controller.
3G3MV-PCORT21
Can open gateway
• Used for running or stopping the inverter, setting or referencing parameters, and monitoring output frequency, output current, or similar items through CANopen communication with the host controller.
SI-T1/V7
MECHATROLINK-II option card
• Used for running or stopping the inverter, setting or referencing parameters, and monitoring output frequency, output current, or similar items through MECHATROLINK-II communication with the host controller.
• High speed motion bus.
• Host controller: TrajeXia, MCH or MP series.
3
1.
Option frame accessory is needed for V7 IP65 types when communications option units are used.
2.
For V7 IP65 types with DeviceNet communication, SI-N1/V7 should be used.
3.
Please refer to TrajeXia, MCH or MP series section for host controller technical information.
C PLC option card
Type Model 1
3G3MV-P10CDT-E
Description
PLC option
Function
• Full PLC featrues, wireless installation and seamless access to the inverter parameters and analogue/digital inputs and outputs.
• Standard OMRON tools can be used for programming
• Calendar / clock
• Same features as standard models with RS 422/485 support.
PLC option with
RS 422/485
3G3MV-P10CDT3-E
1.
Option frame accessory is needed on V7 IP65 types when PLC option unit is used.
D
Option frame accessory for V7 IP65
Type Model Description
V7TZ-FR1
Function
• Frame accessory is needed when communication option unit or PLC option unit are used with Varispeed V7 IP65.
Option frame
Frequency inverters
18
E
Accessories
Types Model
JVOP-146
JVOP-144
72606-CVS31060
3G3IV-PEZZ0838BA
3G3IV-PCN126
3G3IV-PCN326
3G3IV-PCN329-E
E Computer software
Types Model
CX-drive
CX-One
Description Functions
Remote digital operator without potentiometer
11 (0.43)
23.1 (0.91)
DATA (15.5)
STOP
78 (3.07)
88 (3.46)
5
(0.2)
1.7
(0.07)
12.2
(0.48)
10.5
(0.41)
30.4
(1.20)
18.2
(0.72)
15.5 (0.61)
70 (2.76)
56 (2.20)
4-M4 SPOT FACING
DEEP 3.5 (0.14)
Remote digital operator with potentiometer
Blank cover
Digital operator case
Digital operator extension cable
1 meter
3 meters
PC configuration cable
11 (0.43)
DIGITAL
OPERATOR
JVOP-140
DSPL
DATA
ENTER
RUN
STOP
RESET
MIN MAX
78 (3.07)
88 (3.46)
5
(0.2)
23.1 (0.91)
15.5 (0.61)
70 (2.76) same as JVOP-144 without operator
10.5
(0.41)
30.4
(1.20)
18.2
(0.72)
-----
-----
-----
56 (2.20)
4-M4 SPOT FACING
DEEP 3.5 (0.14)
Description
Computer software
Computer software
Installation
Configuration and monitoring software tool
Configuration and monitoring software tool
F Braking unit, braking resistor unit
Voltage
Inverter
Max. applicable motor output kW
Inverter model
CIMR-V7AZ
Inverter-mounted type
(3 %ED, 10 sec max)
Braking resistor unit
Separately-installed type
(10 %ED, 10 sec. max.)
200 V
(single-/ three-phase)
400 V
(threephase)
2.2
4.0
5.5
7.5
0.37
0.55
1.1
1.5
2.2
0.12
0.25
0.55
1.1
1.5
3.0
4.0
5.5
7.5
Singlephase
B2P2
B4P0
–
–
–
–
–
–
–
–
–
–
–
B0P1
B0P2
B0P4
B0P7
B1P5
Threephase
20P1
20P2
20P4
20P7
21P5
22P2
24P0
25P5
27P5
40P2
40P4
40P7
41P5
42P2
43P0
44P0
45P5
47P5
Model
ERF-
150WJ_
401
401
201
201
101
700
620
–
–
751
751
751
401
301
401
–
–
Resistance
Ω
400
400
200
200
100
70
62
–
–
750
750
750
400
300
400
–
–
No. of used
1
1
1
1
–
1
1
1
–
1
1
1
1
1
Braking torque %
120
100
–
–
230
230
130
125
115
220
220
220
125
125
2
–
–
105
–
–
Model
LKEB-
#
–
–
20P7
20P7
21P5
22P2
23P7
25P5
27P5
–
40P7
40P7
41P5
42P2
43P7
45P5
47P5
Resistor spec.
(per one unit)
W Ω
–
–
70 200
70 200
260 100
260 70
390 40
520 30
780 20
–
70 750
70 750
260 400
260 250
No. of used
Braking torque %
1
1
1
1
1
–
1
1
1
–
–
1
1
1
120
125
115
125
–
230
130
125
135
–
–
220
125
125
390 150
520 100
780 75
1
1
1
135
135
130
Connectable min. resistance Ω
300
300
200
120
60
60
32
9.6
9.6
750
750
510
240
200
100
32
32
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
Cat. No. I20E-EN-02 In the interest of product improvement, specifications are subject to change without notice.
Varispeed V7
21
E
Accessories
Types Model
JVOP-146
JVOP-144
72606-CVS31060
3G3IV-PEZZ0838BA
3G3IV-PCN126
3G3IV-PCN326
3G3IV-PCN329-E
E Computer software
Types Model
CX-drive
CX-One
Description Functions
Remote digital operator without potentiometer
11 (0.43)
23.1 (0.91)
DATA (15.5)
STOP
78 (3.07)
88 (3.46)
5
(0.2)
1.7
(0.07)
12.2
(0.48)
10.5
(0.41)
30.4
(1.20)
18.2
(0.72)
15.5 (0.61)
70 (2.76)
56 (2.20)
4-M4 SPOT FACING
DEEP 3.5 (0.14)
Remote digital operator with potentiometer
Blank cover
Digital operator case
Digital operator extension cable
1 meter
3 meters
PC configuration cable
11 (0.43)
DIGITAL
OPERATOR
JVOP-140
DSPL
DATA
ENTER
RUN
STOP
RESET
MIN MAX
78 (3.07)
88 (3.46)
5
(0.2)
23.1 (0.91)
15.5 (0.61)
70 (2.76) same as JVOP-144 without operator
10.5
(0.41)
30.4
(1.20)
18.2
(0.72)
-----
-----
-----
56 (2.20)
4-M4 SPOT FACING
DEEP 3.5 (0.14)
Description
Computer software
Computer software
Installation
Configuration and monitoring software tool
Configuration and monitoring software tool
F Braking unit, braking resistor unit
Voltage
Inverter
Max. applicable motor output kW
Inverter model
CIMR-V7AZ
Inverter-mounted type
(3 %ED, 10 sec max)
Braking resistor unit
Separately-installed type
(10 %ED, 10 sec. max.)
200 V
(single-/ three-phase)
400 V
(threephase)
2.2
4.0
5.5
7.5
0.37
0.55
1.1
1.5
2.2
0.12
0.25
0.55
1.1
1.5
3.0
4.0
5.5
7.5
Singlephase
B2P2
B4P0
–
–
–
–
–
–
–
–
–
–
–
B0P1
B0P2
B0P4
B0P7
B1P5
Threephase
20P1
20P2
20P4
20P7
21P5
22P2
24P0
25P5
27P5
40P2
40P4
40P7
41P5
42P2
43P0
44P0
45P5
47P5
Model
ERF-
150WJ_
401
401
201
201
101
700
620
–
–
751
751
751
401
301
401
–
–
Resistance
Ω
400
400
200
200
100
70
62
–
–
750
750
750
400
300
400
–
–
No. of used
1
1
1
1
–
1
1
1
–
1
1
1
1
1
Braking torque %
120
100
–
–
230
230
130
125
115
220
220
220
125
125
2
–
–
105
–
–
Model
LKEB-
#
–
–
20P7
20P7
21P5
22P2
23P7
25P5
27P5
–
40P7
40P7
41P5
42P2
43P7
45P5
47P5
Resistor spec.
(per one unit)
W Ω
–
–
70 200
70 200
260 100
260 70
390 40
520 30
780 20
–
70 750
70 750
260 400
260 250
No. of used
Braking torque %
1
1
1
1
1
–
1
1
1
–
–
1
1
1
120
125
115
125
–
230
130
125
135
–
–
220
125
125
390 150
520 100
780 75
1
1
1
135
135
130
Connectable min. resistance Ω
300
300
200
120
60
60
32
9.6
9.6
750
750
510
240
200
100
32
32
Frequency inverters
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
Cat. No. I20E-EN-02 In the interest of product improvement, specifications are subject to change without notice.
20
omRon eURoPe B.V.
Wegalaan 67-69, NL-2132 JD, Hoofddorp, The Netherlands. Tel: +31 (0) 23 568 13 00 Fax: +31 (0) 23 568 13 88 www.omron-industrial.com
United Kingdom omron electronics Ltd
Opal Drive, Fox Milne, Milton Keynes, MK15 0DG, UK
Tel: +44 (0) 870 752 08 61
Fax: +44 (0) 870 752 08 62 www.omron.co.uk
Austria
Tel: +43 (0) 1 80 19 00 www.omron.at
Belgium
Tel: +32 (0) 2 466 24 80 www.omron.be
Czech Republic
Tel: +420 234 602 602 www.omron.cz denmark
Tel: +45 43 44 00 11 www.omron.dk
Finland
Tel: +358 (0) 207 464 200 www.omron.fi
France
Tel: +33 (0) 1 56 63 70 00 www.omron.fr germany
Tel: +49 (0) 2173 680 00 www.omron.de
Hungary
Tel: +36 (0) 1 399 30 50 www.omron.hu italy
Tel: +39 02 326 81 www.omron.it netherlands
Tel: +31 (0) 23 568 11 00 www.omron.nl norway
Tel: +47 (0) 22 65 75 00 www.omron.no
Poland
Tel: +48 (0) 22 645 78 60 www.omron.pl
Portugal
Tel: +351 21 942 94 00 www.omron.pt
Russia
Tel: +7 495 745 26 64 www.omron-industrial.ru
Spain
Tel: +34 913 777 900 www.omron.es
Sweden
Tel: +46 (0) 8 632 35 00 www.omron.se
Switzerland
Tel: +41 (0) 41 748 13 13 www.omron.ch turkey
Tel: +90 (0) 216 474 00 40 www.omron.com.tr
middle east & Africa
Tel: +31 (0) 23 568 11 00 www.omron-industrial.com
more omron representatives www.omron-industrial.com
Authorised Distributor:
KPP_V7_01_EN
Control Systems
• Programmable logic controllers • Human-machine interfaces • Remote I/O motion & drives
• Motion controllers • Servo systems • Inverters
Control Components
• Temperature controllers • Power supplies • Timers • Counters • Programmable relays
• Digital panel indicators • Electromechanical relays • Monitoring products • Solid-state relays
• Limit switches • Pushbutton switches • Low voltage switch gear
Sensing & Safety
• Photoelectric sensors • Inductive sensors • Capacitive & pressure sensors • Cable connectors
• Displacement & width-measuring sensors • Vision systems • Safety networks • Safety sensors
• Safety units/relay units • Safety door/guard lock switches
Although we strive for perfection, Omron Europe BV and/or its subsidiary and affiliated companies do not warrant or make any representations regarding the correctness or completeness of the information described in this document.
We reserve the right to make any changes at any time without prior notice.
डाउनलोड
विज्ञापन