Campbell 52202 Instruction Manual


Add to my manuals
26 Pages

advertisement

Campbell 52202 Instruction Manual | Manualzz

52202 Electrically Heated Rain and Snow Gage

Revision: 4/15

C o p y r i g h t © 2 0 1 0 - 2 0 1 5

C a m p b e l l S c i e n t i f i c , I n c .

Limited Warranty

“Products manufactured by CSI are warranted by CSI to be free from defects in materials and workmanship under normal use and service for twelve months from the date of shipment unless otherwise specified in the corresponding product manual. (Product manuals are available for review online at www.campbellsci.com

.) Products not manufactured by CSI, but that are resold by CSI, are warranted only to the limits extended by the original manufacturer.

Batteries, fine-wire thermocouples, desiccant, and other consumables have no warranty. CSI’s obligation under this warranty is limited to repairing or replacing (at CSI’s option) defective Products, which shall be the sole and exclusive remedy under this warranty. The Customer assumes all costs of removing, reinstalling, and shipping defective Products to CSI. CSI will return such Products by surface carrier prepaid within the continental United States of

America. To all other locations, CSI will return such Products best way CIP

(port of entry) per Incoterms ® 2010. This warranty shall not apply to any

Products which have been subjected to modification, misuse, neglect, improper service, accidents of nature, or shipping damage. This warranty is in lieu of all other warranties, expressed or implied. The warranty for installation services performed by CSI such as programming to customer specifications, electrical connections to Products manufactured by CSI, and Product specific training, is part of CSI's product warranty. CSI EXPRESSLY DISCLAIMS AND

EXCLUDES ANY IMPLIED WARRANTIES OF MERCHANTABILITY

OR FITNESS FOR A PARTICULAR PURPOSE . CSI hereby disclaims, to the fullest extent allowed by applicable law, any and all warranties and conditions with respect to the Products, whether express, implied or statutory, other than those expressly provided herein.

Assistance

Products may not be returned without prior authorization. The following contact information is for US and international customers residing in countries served by Campbell Scientific, Inc. directly. Affiliate companies handle repairs for customers within their territories. Please visit www.campbellsci.com

to determine which Campbell Scientific company serves your country.

To obtain a Returned Materials Authorization (RMA), contact CAMPBELL

SCIENTIFIC, INC., phone (435) 227-9000. After an application engineer determines the nature of the problem, an RMA number will be issued. Please write this number clearly on the outside of the shipping container. Campbell

Scientific’s shipping address is:

CAMPBELL SCIENTIFIC, INC.

RMA#_____

815 West 1800 North

Logan, Utah 84321-1784

For all returns, the customer must fill out a “Statement of Product Cleanliness and Decontamination” form and comply with the requirements specified in it.

The form is available from our web site at www.campbellsci.com/repair . A completed form must be either emailed to [email protected]

or faxed to

(435) 227-9106. Campbell Scientific is unable to process any returns until we receive this form. If the form is not received within three days of product receipt or is incomplete, the product will be returned to the customer at the customer’s expense. Campbell Scientific reserves the right to refuse service on products that were exposed to contaminants that may cause health or safety concerns for our employees.

Precautions

DANGER — MANY HAZARDS ARE ASSOCIATED WITH INSTALLING, USING, MAINTAINING, AND WORKING ON OR AROUND

TRIPODS, TOWERS, AND ANY ATTACHMENTS TO TRIPODS AND TOWERS SUCH AS SENSORS, CROSSARMS, ENCLOSURES,

ANTENNAS, ETC . FAILURE TO PROPERLY AND COMPLETELY ASSEMBLE, INSTALL, OPERATE, USE, AND MAINTAIN TRIPODS,

TOWERS, AND ATTACHMENTS, AND FAILURE TO HEED WARNINGS, INCREASES THE RISK OF DEATH, ACCIDENT, SERIOUS

INJURY, PROPERTY DAMAGE, AND PRODUCT FAILURE. TAKE ALL REASONABLE PRECAUTIONS TO AVOID THESE HAZARDS.

CHECK WITH YOUR ORGANIZATION'S SAFETY COORDINATOR (OR POLICY) FOR PROCEDURES AND REQUIRED PROTECTIVE

EQUIPMENT PRIOR TO PERFORMING ANY WORK.

Use tripods, towers, and attachments to tripods and towers only for purposes for which they are designed. Do not exceed design limits. Be familiar and comply with all instructions provided in product manuals. Manuals are available at www.campbellsci.com or by telephoning (435) 227-9000 (USA). You are responsible for conformance with governing codes and regulations, including safety regulations, and the integrity and location of structures or land to which towers, tripods, and any attachments are attached. Installation sites should be evaluated and approved by a qualified engineer. If questions or concerns arise regarding installation, use, or maintenance of tripods, towers, attachments, or electrical connections, consult with a licensed and qualified engineer or electrician.

General

• Prior to performing site or installation work, obtain required approvals and permits. Comply with all governing structure-height regulations, such as those of the FAA in the USA.

• Use only qualified personnel for installation, use, and maintenance of tripods and towers, and any attachments to tripods and towers. The use of licensed and qualified contractors is highly recommended.

• Read all applicable instructions carefully and understand procedures thoroughly before beginning work.

• Wear a hardhat and eye protection , and take other appropriate safety precautions while working on or around tripods and towers.

• Do not climb tripods or towers at any time, and prohibit climbing by other persons. Take reasonable precautions to secure tripod and tower sites from trespassers.

• Use only manufacturer recommended parts, materials, and tools.

Utility and Electrical

• You can be killed or sustain serious bodily injury if the tripod, tower, or attachments you are installing, constructing, using, or maintaining, or a tool, stake, or anchor, come in contact with overhead or underground utility lines .

• Maintain a distance of at least one-and-one-half times structure height, 20 feet, or the distance required by applicable law, whichever is greater , between overhead utility lines and the structure (tripod, tower, attachments, or tools).

• Prior to performing site or installation work, inform all utility companies and have all underground utilities marked.

• Comply with all electrical codes. Electrical equipment and related grounding devices should be installed by a licensed and qualified electrician.

Elevated Work and Weather

• Exercise extreme caution when performing elevated work.

• Use appropriate equipment and safety practices.

• During installation and maintenance, keep tower and tripod sites clear of un-trained or nonessential personnel. Take precautions to prevent elevated tools and objects from dropping.

• Do not perform any work in inclement weather, including wind, rain, snow, lightning, etc.

Maintenance

• Periodically (at least yearly) check for wear and damage, including corrosion, stress cracks, frayed cables, loose cable clamps, cable tightness, etc. and take necessary corrective actions.

• Periodically (at least yearly) check electrical ground connections.

WHILE EVERY ATTEMPT IS MADE TO EMBODY THE HIGHEST DEGREE OF SAFETY IN ALL CAMPBELL SCIENTIFIC PRODUCTS,

THE CUSTOMER ASSUMES ALL RISK FROM ANY INJURY RESULTING FROM IMPROPER INSTALLATION, USE, OR

MAINTENANCE OF TRIPODS, TOWERS, OR ATTACHMENTS TO TRIPODS AND TOWERS SUCH AS SENSORS, CROSSARMS,

ENCLOSURES, ANTENNAS, ETC.

Table of Contents

PDF viewers: These page numbers refer to the printed version of this document. Use the

PDF reader bookmarks tab for links to specific sections.

1.

Introduction ................................................................. 1

2.

Cautionary Statements ............................................... 1

3.

Initial Inspection ......................................................... 1

4.

Quickstart .................................................................... 2

5.

Overview ...................................................................... 4

5.1

Wind Screen ......................................................................................... 4

6.

Specifications ............................................................. 5

7.

Installation ................................................................... 5

7.1

Siting .................................................................................................... 6

7.2

Mounting .............................................................................................. 6

7.3

Wiring .................................................................................................. 8

7.3.1

Heater Wiring ............................................................................... 8

7.3.2

Wiring to the Datalogger .............................................................. 8

7.4

Datalogger Programming ..................................................................... 9

8.

Troubleshooting and Maintenance ........................... 9

8.1

Maintenance ....................................................................................... 10

8.2

Troubleshooting ................................................................................. 10

9.

Attribution ................................................................. 10

Appendices

A.

Importing Short Cut Code Into a Program

Editor ..................................................................... A-1

B.

Example Programs ................................................. B-1

B.1

Pulse Channel Example Programs ................................................... B-1

B.1.1

CR1000 Program ...................................................................... B-1

B.1.2

CR200(X) Series Program ........................................................ B-2

B.1.3

CR6 Program ............................................................................ B-3

B.2

Control Port Example ....................................................................... B-4

i

Table of Contents

Figures

7-1. 52202 Precipitation Gage .................................................................... 6

7-2. The CM220 mounted to a crossarm .................................................... 7

7-3. The CM216 atop a stainless-steel tripod ............................................. 7

Tables

7-1. Wiring for Pulse Channel Input ........................................................... 8

7-2. Multipliers ........................................................................................... 9

ii

52202 Electrically Heated Rain and

Snow Gage

1. Introduction

The 52202, manufactured by R. M. Young, is an electrically heated tipping bucket rain gage that measures rain, snow, and other frozen precipitation. Its catchment area of 200 cm 2 and measurement resolution of 0.1 mm meet the recommendations of the WMO. This heated rain gage is compatible with all

Campbell Scientific dataloggers, and it is used in environmental monitoring applications.

NOTE This manual provides information only for CRBasic dataloggers.

It is also compatible with most of our retired Edlog dataloggers.

For Edlog datalogger support, see an older manual at www.campbellsci.com/old-manuals or contact a Campbell

Scientific application engineer for assistance.

2. Cautionary Statements

READ AND UNDERSTAND the Precautions section at the front of this

manual.

WARNING: Disconnect heater power before attempting to service or repair this equipment. Failure to do so may result in personal injury or death due to electrocution.

Debris filters, funnel, and bucket reservoirs should be kept clean.

The 52202 is a precision instrument that must be handled with care.

The black outer jacket of the cable is Santoprene ® rubber. This compound was chosen for its resistance to temperature extremes, moisture, and UV degradation. However, this jacket will support combustion in air. It is rated as slow burning when tested according to U.L. 94 H.B. and will pass

FMVSS302. Local fire codes may preclude its use inside buildings.

3. Initial Inspection

Upon receipt of the 52202, inspect the packaging and contents for damage.

File damage claims with the shipping company.

The model number and cable length are printed on a label at the connection end of the cable. Check this information against the shipping documents to ensure the correct product and cable length are received.

1

52202 Electrically Heated Rain and Snow Gage

4. Quickstart

Short Cut is an easy way to program your datalogger to measure the 52202 and assign datalogger wiring terminals. The following procedures shows using

Short Cut to program the 52202.

1.

Install Short Cut by clicking on the install file icon. Get the install file from either www.campbellsci.com

, the ResourceDVD, or find it in installations of LoggerNet , PC200W , PC400 , or RTDAQ software.

2.

The Short Cut installation should place a Short Cut icon on the desktop of your computer. To open Short Cut , click on this icon.

3.

When Short Cut opens, select New Program .

2

52202 Electrically Heated Rain and Snow Gage

4.

Select Datalogger Model and Scan Interval (default of 5 seconds is OK for most applications). Click Next .

5.

Under the Available Sensors and Devices list, select the Sensors |

Meteorological | Precipitation folder. Select 52202 Rain Gauge . Click

to move the selection to the Selected device window. Data defaults to millimeters. This can be changed by clicking the mm box and selecting inch .

3

52202 Electrically Heated Rain and Snow Gage

6.

After selecting the sensor, click at the left of the screen on Wiring

Diagram to see how the sensor is to be wired to the datalogger. The wiring diagram can be printed out now or after more sensors are added.

7.

Select any other sensors you have, then finish the remaining Short Cut steps to complete the program. The remaining steps are outlined in Short

Cut Help , which is accessed by clicking on Help | Contents |

Programming Steps .

8.

If LoggerNet , PC400 , RTDAQ , or PC200W is running on your PC, and the

PC to datalogger connection is active, you can click Finish in Short Cut and you will be prompted to send the program just created to the datalogger.

9.

If the sensor is connected to the datalogger, as shown in the wiring diagram in step 6, check the output of the sensor in the datalogger support software data display to make sure it is making reasonable measurements.

5. Overview

The 52202 funnels precipitation into a bucket mechanism that tips when filled to the calibrated level. Each tip is marked by a magnetic reed switch closure that is recorded by a Campbell Scientific datalogger pulse count channel.

The 52202 has an internal heater that melts snow or other frozen precipitation.

This heater is thermostat controlled and requires a reliable source of 24 Vac power. A wall transformer is shipped with the 52202 that plugs into a wall socket to provide the required 24 Vac power.

5.1 Wind Screen

Campbell Scientific offers the 260-953 Wind Screen to help minimize the effect of wind on rain measurements. This wind screen consists of 32 freely hanging leaves that swing as wind moves past them. Refer to the 260-953 manual for siting information and the installation procedure.

4

52202 Electrically Heated Rain and Snow Gage

6. Specifications

Features:

High precision—tips at 0.1 mm increments

Heating element melts snow and ice for year-round measurement

Compatible with Campbell Scientific CRBasic dataloggers: CR6,

CR200(X) series, CR800, CR850, CR1000, CR3000, CR5000, and

CR9000(X)

Sensor Type:

Accuracy:

Resolution:

Tipping bucket with magnetic reed switch, normally open

2% up to 25 mm h –1 (1 in h –1 );

3% up to 50 mm h –1 (2 in h –1 )

0.1 mm (0.004 in)

Orifice Diameter:

Catchment Area:

Temperature Range:

Humidity Range:

16 cm (6.3 in)

31 in 2 (200 cm 2 )

– 20 to 50 °C (heated)

0 to 100%

Power:

Contact Rating:

18 W @ 24 Vac

24 Vac/dc, 400 mA maximum

Heater Thermostat Set Point: 10 °C ± 3 °C

Sensor Diameter: 18.5 cm (7.3 in)

Height: 30 cm (11.8 in)

Mounting: Standard 1 inch pipe size, 34 mm (1.34 in) outer diameter

7. Installation

NOTE The 260-953 Alter-Type Wind Screen’s siting information and installation procedure are provided in the 260-953 manual.

If you are programming your datalogger with Short Cut

, skip Section 7.3

,

Wiring

(p. 8)

, and Section 7.4

, Datalogger Programming

(p. 9)

.

Short Cut does

this work for you. See Section 4 , Quickstart

(p. 2)

, for a Short Cut tutorial.

5

52202 Electrically Heated Rain and Snow Gage

7.1 Siting

The 52202 should be mounted in a relatively level spot which is representative of the surrounding area. The lip of the funnel should be horizontal and at least

30 cm above the ground. It should be high enough to be above the average snow depth. The ground surface around the rain gage should be natural vegetation or gravel. It should not be paved.

The gage should be placed away from objects that obstruct the wind. The distance should be two to four times the height of the obstruction.

7.2 Mounting

The 52202 precipitation gage uses a clamp to fasten onto the 3659 12-inch-

long, aluminum pipe or to a user-supplied 1-inch IPS pipe (see FIGURE 7-1 ).

The 3659 pipe is shipped with the 52202 gage.

Housing

Base

Clamp

FIGURE 7-1. 52202 Precipitation Gage

The pipe attaches to a CM202, CM204, or CM206 crossarm via a CM220

Right Angle Mounting Bracket (see FIGURE 7-2 ). The crossarm attaches to a

tripod mast, tower leg, CM300-series mounting pole, or a user-supplied vertical pipe (1.0-inch to 2.1-inch OD).

6

52202 Electrically Heated Rain and Snow Gage

Crossarm

CM220

FIGURE 7-2. The CM220 mounted to a crossarm

Alternatively, the 3659 pipe can be attached to the top of our stainless-steel tripods via the CM216 Sensor Mounting Kit. The CM216 extends 4 inches above the mast of a stainless-steel CM110, CM115, or CM120 tripod (see

FIGURE 7-3 ).

Fits in Mast

FIGURE 7-3. The CM216 atop a stainless-steel tripod

7

52202 Electrically Heated Rain and Snow Gage

After mounting the 52202, level the gage and remove the shipping retainer by performing the following procedure:

1.

Loosen the three screws that retain housing to base assembly (see FIGURE

7-1 ). Carefully lift housing free of base.

2.

Remove shipping retainer from bucket. Verify that bucket tips freely.

3.

Adjust leveling screws until bullseye level is centered.

4.

Replace housing and retighten screws.

7.3 Wiring

WARNING Disconnect heater power before attempting to service or repair this equipment. Failure to do so may result in personal injury or death due to electrocution.

7.3.1 Heater Wiring

Attach the power plug supplied with the 52202 by following the instructions supplied with the plug. This gage requires an adequately grounded, reliable source of 24 Vac power.

7.3.2 Wiring to the Datalogger

NOTE When Short Cut software is used to generate the datalogger program, the sensor should be wired to the channels shown on the wiring diagram created by Short Cut .

The 52202 is wired to a datalogger as shown in TABLE 7-1 .

TABLE 7-1. Wiring for Pulse Channel Input

Wire

Color

Wire

Function

Datalogger Connection

Terminal for Pulse

Channel Input

Datalogger Connection

Terminal for Control

Port Input*

Black

White

Clear

Signal

Signal

Return

Shield

P, P_SW, or U

(pulse channel)

or AG

(analog ground)

or AG (analog ground)

C (control port)

5 V

(on datalogger)

or AG

(analog ground)

* Dataloggers capable of measuring pulse counts on their control ports include CR800series, CR1000, and CR3000.

8

52202 Electrically Heated Rain and Snow Gage

7.4 Datalogger Programming

Short Cut is the best source for up-to-date datalogger programming code.

Programming code is needed,

• when creating a program for a new datalogger installation

• when adding sensors to an existing datalogger program

If your data acquisition requirements are simple and you are connecting the sensor to a pulse port, you can probably create and maintain a datalogger program exclusively with Short Cut . If your data acquisition needs are more complex, the files that Short Cut creates are a great source for programming code to start a new program or add to an existing custom program.

NOTE Short Cut cannot edit programs after they are imported and edited in CRBasic Editor .

A Short Cut

tutorial is available in Section 4 , Quickstart

(p. 2)

. If you wish to import Short Cut code into CRBasic Editor to create or add to a customized

program, follow the procedure in Appendix A , Importing Short Cut Code Into a Program Editor

(p. A-1)

. Programming basics for CRBasic dataloggers are

provided in the following sections. Complete program examples for select

CRBasic dataloggers can be found in Appendix B , Example Programs

(p. B-1)

.

Programming basics and programming examples for Edlog dataloggers are provided at www.campbellsci.com\old-manuals .

The PulseCount() instruction programs CRBasic dataloggers (CR200(X),

CR6, CR800, CR850, CR1000, CR3000, CR5000, CR9000(X)) to measure the

52202 rain gage.

PulseCount (Dest,Reps,PChan,PConfig,POption,Mult,Offset)

Choose Switch Closure (code 2) for the PConfig parameter.

The Multiplier parameter determines the units in which rainfall is

reported (TABLE 7-2 ).

TABLE 7-2. Multipliers

Unit

1 in

1 mm

Multiplier

0.00394

0.1

8. Troubleshooting and Maintenance

NOTE All factory repairs and recalibrations require a returned material authorization (RMA) and completion of the “Declaration of

Hazardous Material and Decontamination” form. Refer to the

Assistance page at the beginning of this manual for more

information.

9

52202 Electrically Heated Rain and Snow Gage

8.1 Maintenance

The rain gage should be inspected periodically. Accumulated dirt and debris should be cleaned from funnel, screen and bucket assembly. Electrical connections should be inspected and cleaned. Leveling screws may be readjusted at this time.

Periodic recalibration may be desirable to ensure measurement accuracy. The following calibration check is advised every 12 months.

1.

With the rain gage properly leveled, slowly pour a measured volume of water into the collection funnel. The rate should be about 10 ml per minute which is approximately 1 inch per hour. The bucket should tip five times for each 10 ml of water. For example, 100 ml should give a count of

50 ±1. Bucket tips may be counted manually or with a counter connected to the rain gage terminals.

2.

If the count shows an error of more than 2%, adjust the calibrating screws to correct the error. Raise the screws if the count is low, lower the screws if the count is high. Always adjust both screws equally.

8.2 Troubleshooting

Symptom: No Precipitation

1.

Check that the sensor is wired to the pulse channel or control port specified by the pulse count instruction.

2.

Verify that the Configuration Code (Switch Closure), and Multiplier and

Offset parameters for the Pulse Count instruction are correct for the datalogger type.

3.

Disconnect the sensor from the datalogger and use an ohm meter to do a continuity check of the switch. The resistance measured at the terminal block on the inside of the bucket between the black and white leads should vary from infinite (switch open) when the bucket is tipped, to less than an ohm when the bucket is balanced.

9. Attribution

Santoprene ® is a registered trademark of Exxon Mobile Corporation.

10

Appendix A. Importing Short Cut Code

Into a Program Editor

This tutorial shows:

How to import a Short Cut program into a program editor for additional refinement.

How to import a wiring diagram from Short Cut into the comments of a custom program.

Short Cut creates files that can be imported into CRBasic Editor . These files normally reside in the C:\campbellsci\SCWin folder and have the following extensions:

.DEF (wiring and memory usage information)

.CR2 (CR200(X) datalogger code)

.CR6 (CR6 datalogger code)

.CR1 (CR1000 datalogger code)

.CR8 (CR800 or CR850 datalogger code)

.CR3 (CR3000 datalogger code)

.CR5 (CR5000 datalogger code)

Use the following procedure to import Short Cut code into CRBasic Editor

(CR200(X), CR6, CR1000, CR800, CR850, CR3000, CR5000 dataloggers).

1. Create the Short Cut

program following the procedure in Section 4 ,

Quickstart

(p. 2)

. Finish the program and exit

Short Cut . Make note of the file name used when saving the Short Cut program.

2. Open CRBasic Editor .

3. Click File | Open . Assuming the default paths were used when Short Cut was installed, navigate to C:\CampbellSci\SCWin folder. The file of interest has a “.CR2”, “.CR6”, “.CR1”, “.CR8”, “.CR3”, or “.CR5” extension, for CR200(X), CR6, CR1000, CR800/CR850, CR3000, or

CR5000 dataloggers, respectively. Select the file and click Open .

4. Immediately save the file in a folder different from \Campbellsci\SCWin, or save the file with a different file name.

NOTE Once the file is edited with CRBasic Editor , Short Cut can no longer be used to edit the datalogger program. Change the name of the program file or move it, or Short Cut may overwrite it next time it is used.

5. The program can now be edited, saved, and sent to the datalogger.

6. Import wiring information to the program by opening the associated .DEF file. Copy and paste the section beginning with heading “-Wiring for

CRXXX–” into the CRBasic program, usually at the head of the file.

After pasting, edit the information such that a ' character (single quotation

A-1

Appendix A. Importing Short Cut Code Into a Program Editor mark) begins each line. This character instructs the datalogger compiler to ignore the line when compiling the datalogger code.

A-2

Appendix B. Example Programs

B.1 Pulse Channel Example Programs

The following example programs use a pulse channel to read the output from the precipitation gage. The CR1000 example will also work with the CR800,

CR850, CR3000, and CR5000. CR9000(X) programming is similar to the

CR1000 except it has an additional parameter in the PulseCount() instruction to specify the pulse module’s slot.

B.1.1 CR1000 Program

'CR1000

'RM_Young Tipping Blk > P1

' Wht > ground

'Cabling for heater goes to 24VAC power supply

Public Rain_mm

Units Rain_mm=mm

DataTable(Rain,True,-1)

DataInterval(0,60,Min,0)

Totalize(1,Rain_mm,FP2,0)

EndTable

BeginProg

Scan(1,Sec,1,0)

PulseCount(Rain_mm,1,1,2,0,0.1,0)

CallTable(Rain)

NextScan

EndProg

B-1

Appendix B. Example Programs

B.1.2 CR200(X) Series Program

'CR200(X) Series

'RM_Young Tipping Blk > P_SW

' Wht > ground

'Cabling for heater goes to 24VAC power supply

'Declare Variables and Units

Public Rain_mm

Units Rain_mm=mm

'Define Data Tables

DataTable(Rain,True,-1)

DataInterval(0,60,Min)

Totalize(1,Rain_mm,0)

EndTable

'Main Program

BeginProg

Scan(1,Sec)

'52202 Rain Gage measurement Rain_mm:

PulseCount(Rain_mm,P_SW,2,0,0.1,0)

'Call Data Tables and Store Data

CallTable(Rain)

NextScan

EndProg

B-2

Appendix B. Example Programs

B.1.3 CR6 Program

'CR6 Series

'Declare Variables and Units

Public BattV

Public PTemp_C

Public Rain_mm

Units BattV=Volts

Units PTemp_C=Deg C

Units Rain_mm=mm

'Define Data Tables

DataTable(Table1,True,-1)

DataInterval(0,60,Min,10)

Totalize(1,Rain_mm,FP2,False)

EndTable

DataTable(Table2,True,-1)

DataInterval(0,1440,Min,10)

Minimum(1,BattV,FP2,False,False)

EndTable

'Main Program

BeginProg

'Main Scan

Scan(5,Sec,1,0)

'Default Datalogger Battery Voltage measurement 'BattV'

Battery(BattV)

'Default Wiring Panel Temperature measurement 'PTemp_C'

PanelTemp(PTemp_C,60)

'52202 Rain Gauge measurement 'Rain_mm'

PulseCount(Rain_mm,1,U1,1,0,0.1,0)

'Call Data Tables and Store Data

CallTable Table1

CallTable Table2

NextScan

EndProg

B-3

Appendix B. Example Programs

B.2 Control Port Example

The following example program uses a control port to read the output from the precipitation gage. The CR1000 example will also work with the CR800,

CR850, and CR3000.

'CR1000

'RM_Young Tipping Blk > C4

' Wht > 5v

'Cabling for heater goes to 24VAC power supply

'Declare Variables and Units

Public BattV

Public RM_Young

Units BattV = Volts

Units RM_Young =inch

DataTable(OneMin,True,-1)

DataInterval(0,1,Min,10)

Totalize (1,RM_Young,FP2,False)

EndTable

'Define Data Tables

DataTable(OneDay,True,-1)

DataInterval(0,1440,Min,10)

Minimum(1,BattV,FP2,False,False)

Totalize (1,RM_Young,FP2,False) 'RM Young tipping bucket

EndTable

'Main Program

BeginProg

Scan(5,Sec,1,0)

'Default Datalogger Battery Voltage measurement BattV

PanelTemp (PTemp,_60Hz)

Battery(BattV)

'RM Young Heated Rain Gage measurement Rain_in

PulseCount(RM_Young,1,14,2,0,0.0039,0)

'Call Data Tables and Store Data

CallTable(OneMin)

CallTable(OneDay)

NextScan

EndProg

B-4

Campbell Scientific Companies

Campbell Scientific, Inc. (CSI)

815 West 1800 North

Logan, Utah 84321

UNITED STATES www.campbellsci.com

[email protected]

Campbell Scientific Africa Pty. Ltd. (CSAf)

PO Box 2450

Somerset West 7129

SOUTH AFRICA www.csafrica.co.za

[email protected]

Campbell Scientific Australia Pty. Ltd. (CSA)

Campbell Scientific Centro Caribe S.A. (CSCC)

300 N Cementerio, Edificio Breller

Santo Domingo, Heredia 40305

COSTA RICA www.campbellsci.cc

[email protected]

Campbell Scientific Ltd. (CSL)

Campbell Park

80 Hathern Road

Shepshed, Loughborough LE12 9GX

UNITED KINGDOM www.campbellsci.co.uk

[email protected]

PO Box 8108

Garbutt Post Shop QLD 4814

AUSTRALIA www.campbellsci.com.au

[email protected]

Campbell Scientific (Beijing) Co., Ltd.

8B16, Floor 8 Tower B, Hanwei Plaza

7 Guanghua Road

Chaoyang, Beijing 100004

P.R. CHINA www.campbellsci.com

[email protected]

Campbell Scientific Ltd. (CSL France)

3 Avenue de la Division Leclerc

92160 ANTONY

FRANCE www.campbellsci.fr

[email protected]

Campbell Scientific Ltd. (CSL Germany)

Fahrenheitstraße 13

28359 Bremen

Campbell Scientific do Brasil Ltda. (CSB)

Rua Apinagé s, nbr. 2018 ─ Perdizes

CEP: 01258-

00 ─

São Paulo

─ SP

BRASIL www.campbellsci.com.br

[email protected]

Campbell Scientific Canada Corp. (CSC)

14532 – 131 Avenue NW

GERMANY www.campbellsci.de

[email protected]

Campbell Scientific Spain, S. L. (CSL Spain)

Avda. Pompeu Fabra 7-9, local 1

08024 Barcelona

SPAIN www.campbellsci.es

[email protected]

Edmonton AB T5L 4X4

CANADA www.campbellsci.ca

[email protected]

Please visit www.campbellsci.com

to obtain contact information for your local US or international representative.

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals