Ikan LSC-005 Light Quick Start Guide
Reklama
Reklama
LSC-005
4000 Watt HMI Fresnel Head (Lightstar)
Quick Start Guide
What’s Included
1 x 4000 Watt Fixture Head
1 x Yoke
1 x Barn Doors
1 x Gel Holder www.ikancorp.com | 1.713.272.8822 | [email protected]
CHECKED BY
because we’re filmmakers too
Ikan is the exclusive distributor of Lightstar products in the United States.
Instructions
The Lightstar LSC-005 4000 Watt HMI Fresnel Head is a compact, dual power, fresnel light.
The fixture uses 4000w 200v G38 socket metal handle lamps.
Safety Precautions
1. The LSC-005 fixture has been designed for professional use and must be operated by qualified personnel only.
2. The 4000W fixture can only be used with the Lightstar electronic ballast that supports 4000W.
Working Conditions
The best position is tilting the fixture 90° from horizontal.
The max ambient temperature limit is ±45° C (113°F).
Please keep a minimum distance of 2 feet when close to inflammable objects.
Do not cover the ventilation holes on the fixture housing. They are necessary for proper ventilation.
Use only original parts and accessories from Lightstar.
Before hanging the fixture, make sure the suspension points are properly rated to handle the weight of the fixture.
It is ALWAYS advisable to add a safety cable or chain through the yoke to properly suspend the fixture in place.
WARNING: DO NOT USE THE LSC-005 IN A SPACE WITH FLAMMABLE SUBSTANCES.
WARNING: UV RISK / HEALTH RISK. THE LAMPS USED WITH THE LSC-005 EMIT AN AMOUNT OF UV RADIATION WHICH CAN BE DANGEROUS TO
HUMAN HEALTH IF NOT PROPERLY SHIELDED AGAINST.
THE FIXTURE MUST NEVER BE USED IN SITUATIONS WHEN DIRECT LIGHT EMISSIONS FROM THE LAMP CAN OCCUR. (Ex: No front glass, no intentional mirror, damaged front housing).
Lamp Installation & Replacement
1. Ensure the fixture is disconnected from the main power supply.
WARNING!! LAMP WILL STILL BE HOT TO THE TOUCH EVEN AFTER THE ALLOTED LAMP REST PERIOD.
THERMAL GLOVES ARE RECOMMENDED FOR WORKING WITH THE FIXTURE AND THE BULB.
2. Check to see that the new lamp is the correct wattage.
3. Release the lamp clamp level inside the front of the fixture.
4. To replace the lamp pull up and out to remove the old lamp.
Re-Lamp Procedures: Do not touch the bulb with your bare-hands. This can cause oil to accumulate on the glass and reduce the performance of lamp life. The plastic/foam cover which protects the lamp should NOT be removed until after the lamp is fitted into the fixture. If bulb becomes dirty due to hand contact or from any contaminant, it can be cleaned with a cloth moistened with alcohol.
5. Re-tighten the lamp clamping device.
6. Close the lens door and securely latch.
www.ikancorp.com | 1.713.272.8822 | [email protected] because we’re filmmakers too
Periodic Fixture Inspection
1. The condition of the internal wiring and ceramic base will need to be inspected and tested every 4000 working hours or at least once a year. This frequency may need to be increased if the fixture has endured rough treatment. All internal components should only be replaced with Lightstar spare parts.
2. The lamps should be checked every 100 working hours. The lamp should be changed if the lamp becomes deformed or damaged, otherwise explosion might occur. Defer to instructions provided by the lamp manufacturer.
3. Always check the safety shield before every use.
4. All high-voltage components (ex: voltage wires, lamp ceramic, external shield, igniter must be inspected every 100 working hours or at least once a year.
5. Outer door hinges and latching system must be checked every 250 working hours to ensure proper seating of the safety shield. This will allow inspections of accessories and the holding clamps.
6. The condition of the internal mirror must be maintained every 250 working hours. It must be replaced whenever it becomes either cracked or broken. It is essential for the performance of the fixture.
Specifications & Photometrics
LSC-005 Specifications
Beam Angle
Build Material
Color Temperature
Cooling System
Fixture Size
Fixture Weight
Focusing
Head Type
IP Class
Lamp Base
Lens Size
Yoke
7° to 60°
Aluminum
5600K
Air Cooled
31 x 24 x 18.9 in.
56 lbs
Knob Control
HMI Fresnel 4000W
IP23
4000W / 200V / G38
Fresnel 11.8"
Cast Aluminum with 1 1/8" Pin
LUX
METERS
LUX
METERS
21250
10M
1750
10M
9445
15M
778
15M www.ikancorp.com | 1.713.272.8822 | [email protected]
5313
20M
438
20M
FC
FEET
FC
FEET
1974.2
29.5'
877.5
39'
493.6
49'
162.6
29.5'
72.3
39'
40.7
49' because we’re filmmakers too
Learn More
More dynamic information at official website: www.ikancorp.com
Support
Contact email: [email protected]
CONDITIONS OF WARRANTY SERVICE
• Free service for one year from the day of purchase if the problem is caused by manufacturing errors.
• The components and maintenance service fee will be charged if the warranty period is expired.
Free Service will not be Provided in the Following Situations:
(*Even if the product is still within the warranty period.)
• Damage caused by abuse or misuse, dismantling, or changes to the product not made by the company.
• Damage caused by natural disaster, abnormal voltage, and environmental factors, etc.
©2017 ikan Corporation. All rights reserved www.ikancorp.com | 1.713.272.8822 | [email protected] because we’re filmmakers too