ATI Technologies B14 O & M Manual

Add to My manuals
45 Pages

advertisement

ATI Technologies B14 O & M Manual | Manualzz

O & M Manual

B14

Monitor System

Home Office

Analytical Technology, Inc.

6 Iron Bridge Drive

Collegeville, PA 19426

Phone: 800-959-0299

610-917-0991

Fax: 610-917-0992

European Office

ATI (UK) Limited

Unit 1 & 2 Gatehead Business Park

Delph New Road, Delph

Saddleworth OL3 5DE

Phone: +44 (0)1457-873-318

Fax: + 44 (0)1457-874-468

Email: [email protected] Email: [email protected]

Web: www.Analyticaltechnology.com

Fax: 610-917-0992 Fax: + 44 (0)1457-874-468

TABLE OF CONTENTS

INTRODUCTION ....................................................................................................................................................... 4

B12 S ENSOR /T RANSMITTER ....................................................................................................................................... 5

B14 R ECEIVER M ODULE ............................................................................................................................................. 5

A17 P OWER S UPPLY M ODULE .................................................................................................................................... 5

NEMA 4X E NCLOSURE .............................................................................................................................................. 5

E XPLOSION PROOF E NCLOSURES ................................................................................................................................ 5

A UDIBLE H ORN .......................................................................................................................................................... 6

S TROBE L AMP ............................................................................................................................................................ 6

A19 B ATTERY B ACK UP ............................................................................................................................................. 6

MECHANICAL INSTALLATION ........................................................................................................................... 7

ELECTRICAL INSTALLATION .......................................................................................................................... 12

B14 RECEIVER MODULE ..................................................................................................................................... 24

E LECTRICAL C ONNECTION ....................................................................................................................................... 24

F ACTORY C ONFIGURATION ...................................................................................................................................... 26

C ONFIGURATION S WITCHES ..................................................................................................................................... 27

O PERATING R ANGE C HART ...................................................................................................................................... 28

S ETPOINT S ELECTION ............................................................................................................................................... 29

R ANGE S ELECTION ................................................................................................................................................... 30

R ELAY C ONFIGURATION ........................................................................................................................................... 30

E XTERNAL H ORN R ELAY .......................................................................................................................................... 31

OPERATION ............................................................................................................................................................. 32

A LARM A CKNOWLEDGE AND R ESET ........................................................................................................................ 32

T ROUBLE A LARM AND R ELAY .................................................................................................................................. 33

L AMP AND H ORN T EST ............................................................................................................................................. 33

I NHIBIT M ODE .......................................................................................................................................................... 33

R EMOTE R ESET ......................................................................................................................................................... 34

A NALOG O UTPUT ..................................................................................................................................................... 34

T ROUBLESHOOTING .................................................................................................................................................. 34

RECEIVER MODULE PARTS LIST ...................................................................................................................... 35

UNIVERSAL POWER SUPPLY ............................................................................................................................. 36

CAUTION ............................................................................................................................................................... 36

POWER SUPPLY PARTS LIST ............................................................................................................................. 38

BATTERY BACK-UP UNIT .................................................................................................................................. 39

I NSTALLATION .......................................................................................................................................................... 39

O PERATION ............................................................................................................................................................... 40

R EMOVAL FROM S ERVICE ......................................................................................................................................... 40

BATTERY BACK-UP PARTS LIST ...................................................................................................................... 41

STROBE LIGHT ...................................................................................................................................................... 42

STROBE PARTS LIST ............................................................................................................................................ 43

O & M Manual

Rev-P (7/15) 2

TABLE OF FIGURES

Figure 1 - Single Module System Enclosure Dimensions (80-0005) ............................................................ 8

Figure 2 - Two Module System Enclosure Dimensions (80-0006) ............................................................... 9

Figure 3 - Three Module System Enclosure Dimensions (80-0007) .......................................................... 10

Figure 4 - Six Module System Enclosure Dimensions (80-0008) ............................................................... 11

Figure 5 - Single Point Receiver Internal Wiring (ATI-0172) ...................................................................... 12

Figure 6 - Dual Point Receiver Internal Wiring (ATI-0173) ......................................................................... 13

Figure 7 - Four Point Receiver Internal Wiring (ATI-0174) ......................................................................... 14

Figure 8 - Receiver Connection to 65W Power Supply (ATI-0545) ............................................................ 15

Figure 9 - Typical System Wiring, Nemz-4 Transmitter Version (ATI-0175) .............................................. 16

Figure 10 - Typical System Wiring, Explosion-Proof B12 Sensor/Transmitter (ATI-0176) ........................ 17

Figure 11 - Typical System Wiring, B12-17 Combustible Sensor/Transmitter (ATI-0215) ......................... 18

Figure 12 - Typical System Wiring, C12-17 Combustible Sensor/Transmitter (ATI-0609) ........................ 19

Figure 13 - Typical System Wiring, A12 2-Wire Transmitter (ATI-0179) .................................................... 20

Figure 14 - Typical System Wiring, A12-17 Combustible Transmitter (ATI-0355) ..................................... 21

Figure 15 - Typical System Wiring, D12 Transmitter (2-Wire Hookup) ( ATI-0610) ................................... 22

Figure 16 - Typical System Wiring, D12 Transmitter (3-Wire Hookup) (ATI-0611) .................................... 23

Figure 17 - Front Panel Controls & LEDs (ATI-0177) ................................................................................. 24

Figure 18 - Receiver Module Terminals (ATI-0178) ................................................................................... 25

Figure 19 - Configuration Board Switch Location ....................................................................................... 28

Figure 20 - Power Supply Terminal Connections (ATI-030) ....................................................................... 37

Figure 21 - Battery Back-up Mounting Dimensions .................................................................................... 39

Figure 22 - External Strobe Light Connections (ATI-0202) ........................................................................ 42

O & M Manual

Rev-P (7/15) 3

ATI

B14 Alarm System Section 1 - Overview

INTRODUCTION

The B14 is an on-line monitoring system for the detection of hazardous gases in ambient air. It is designed to detect and alarm gas leaks from storage cylinders, process piping, or gas feed equipment in virtually any type of industrial plant environment. Systems are available for monitoring a variety of gases as shown in Table 1-1.

TABLE 1-1

GAS CODE NO. STD. RANGE MIN. RANGE MAX. RANGE

GENERAL GASES

Ammonia

Carbon Monoxide

Hydrogen

Nitric Oxide

Oxygen

Phosgene

Bromine

Chlorine

Chlorine Dioxide

Fluorine

Hydrogen Peroxide

Ozone

Iodine

15

16

18

25

19

20

10

11

12

13

34

14

35

0-100 PPM

0-100 PPM

0-4 %

0-100 PPM

0-25%

0-2 PPM

OXIDANT GASES

0-2 PPM

0-10 PPM

0-2 PPM

0-2 PPM

0-10 PPM

0-2 PPM

0-2 PPM

ACID GASES

0-50 PPM

0-50 PPM

0-2000 PPM

0-25 PPM

0-10%

0-1 PPM

0-1 PPM

0-1 PPM

0-1 PPM

0-1 PPM

0-10 PPM

0-1 PPM

0-1 PPM

0-500 PPM

0-500 PPM

0-10 %

0-500 PPM

0-100%

0-100 PPM

0-100 PPM

0-100 PPM

0-100 PPM

0-100 PPM

0-100 PPM

0-100 PPM

0-100 PPM

Hydrogen Chloride

Hydrogen Cyanide

Hydrogen Fluoride

Hydrogen Sulfide

Nitrogen Dioxide

Sulfur Dioxide

21

22

23

24

26

27

0-20 PPM

0-20 PPM

0-20 PPM

0-50 PPM

0-20 PPM

0-20 PPM

HYDRIDE GASES

0-10 PPM

0-10 PPM

0-10 PPM

0-10 PPM

0-5 PPM

0-10 PPM

0-200 PPM

0-200 PPM

0-200 PPM

0-500 PPM

0-200 PPM

0-200 PPM

Arsine

Diborane

Germane

Hydrogen Selenide

Phosphine

Silane

28

29

30

31

32

33

0-1000 PPB

0-1000 PPB

0-1000 PPB

0-1000 PPB

0-1000 PPB

0-10 PPM

0-1000 PPB

0-1000 PPB

0-1000 PPB

0-1000 PPB

0-1000 PPB

0-1000 PPB

0-100 PPM

0-100 PPM

0-100 PPM

0-100 PPM

0-100 PPM

0-100 PPM

The B14 system consists of modular components that can be used in a variety of configurations to fit specific application requirements. A description of the major system components follows:

O & M Manual

Rev-P (7/15) 4

ATI

B14 Alarm System Section 1 - Overview

B12 Sensor/Transmitter

Consists of an electrochemical gas sensor closely coupled to a NEMA 4X transmitter. This component measures gas concentration and converts the measurement to 4-20 mA current for transmission to a receiver module. It must be mounted in the area where gas leakage or buildup is expected, and can either be wall mounted or supported by electrical conduit carrying interconnecting wiring. For hazardous areas, explosion-proof sensor/transmitters are available.

B14 Receiver Module

Receives current data from the sensor/transmitter and provides an LED display of gas concentration, three gas alarm setpoints, three gas alarm relays, an isolated 4-20 mA output, and a trouble alarm and relay. The receiver is packaged in a compact DIN rail mount housing, and fits easily into NEMA 4X enclosures suitable for one, two, three, or six modules. Each module is switch programmable for full scale range, alarm setpoints, relay latch/non-latch operation, and relay normal/fail-safe operation. A single switch (marked A/R) on the front panel provides alarm acknowledge and reset functions, and can also be used to test front panel LED indicators and to inhibit alarm relays. LED bars on the front panel provide visual indication of alarm status.

A17 Power Supply Module

Provides 12 VDC power to one or two receiver modules plus power for an audible horn and for charging an external battery. Packaged in the same compact DIN rail mount module used for the receiver, the power supply is designed for use throughout the world. Input to this module may be any AC

(50 or 60 Hz.) or DC voltage between 85 and 270 volts. The supply is self-regulating, meaning no jumper changes, no changes in switch settings, and no variation in wiring pattern. A power failure alarm relay is included in the module to signal the loss of input power.

NEMA 4X Enclosure

Four standard enclosures are available for housing receiver and power supply modules. Polystyrene enclosures are suitable for outdoor environments, and digital displays and alarm indicators are clearly visible through a clear polycarbonate window on the front. The window hinges open to gain access to the receiver A/R control switch, and the entire front section of the enclosure can be removed for ease of mounting and wiring. Enclosures are provided with knockouts on all four sides to facilitate wiring, and ½”

FNPT conduit hubs are provided with each enclosure.

Explosion-proof Enclosures

Two versions are available to allow use of the receiver and power supply modules in hazardous areas. One version is suitable for a single receiver module, while the second is large enough to contain both a power supply and a receiver. Enclosures are rated for Class 1, Division 1, Groups C & D. Group

B enclosures are also available if required. All explosion-proof enclosures can be supplied with an external acknowledge and reset switch.

O & M Manual

Rev-P (7/15) 5

ATI

B14 Alarm System Section 1 - Overview

Audible Horn

A 12 VDC piezoelectric alarm horn is available for mounting into any of the NEMA 4X enclosures.

The horn is wired to the receiver module and will sound intermittently when the warning setpoint is reached, and continuously when the alarm setpoint is reached. The horn can be silenced by pushing the

A/R switch on the receiver front panel. A single horn can be wired through multiple receivers and will sound if any receiver goes into alarm.

Strobe Lamp

Provides a bright visual indication of an alarm condition. The strobe uses a xenon flash lamp to give a high intensity flash approximately 70 times a minute. The strobe is wired to one of the alarm relays, with power for the strobe supplied from the power supply module. Mounting is by ½” MNPT nipple, making it convenient to mount directly to a NEMA enclosure.

A19 Battery Back-up

Provides a 12 VDC, 4 AH battery and charging control circuitry in a separate NEMA 4X enclosure.

The battery backup connects directly to the A17 power supply module to provide standby power to the detection system. If AC power is lost, the battery insures that detection continues uninterrupted.

B14 components allow simple assembly of either single or multipoint detection systems. Each point of detection requires one sensor/transmitter and one receiver. The sensor/transmitter is mounted in the hazard area, and the receiver is located anywhere within 1000 feet. If the user has a regulated 12-28

VDC power supply and an enclosure to house the receiver, nothing else is required. If not, one power supply for every two receivers is needed for power, and an enclosure of a size to contain the modules is needed for environmental protection. An optional horn and strobe may be added if desired.

O & M Manual

Rev-P (7/15) 6

ATI

B14 Alarm System Section 2 – Mechanical Installation

MECHANICAL INSTALLATION

System enclosures, battery back-up units, and sensor transmitters are all designed for surface mounting using screws or bolts inserted through the recessed mounting holes at each corner of the enclosures. Included with each system enclosure is a template with mounting hole dimensions for two and three module system enclosures, battery back-up enclosure, and sensor/transmitter enclosure. The template can be used to mark hole centers on walls or mounting panels.

Mounting recesses are suitable for #6 or #8 machine screws or wood screws. Screw length will vary with specific site conditions.

Two and three module system enclosures provide knockouts on all four sides to allow wiring conduit to be connected in the most convenient way. Enclosures are shipped with all knockouts in place except for the larger knockout on the bottom, where the audible horn is installed if ordered. See Pages 1-6 through 1-9 for dimensional drawings of the one, two, three and six module enclosures.

Each enclosure is supplied with conduit hubs for connection of ½” NPT threaded conduit. Also included is a seal ring for each hub. Seal rings are required to provide a water tight conduit hub connection to the enclosure.

The following lists the number of hubs that should be included with each enclosure type.

Two module Enclosure - 4 hubs

Three module Enclosure - 6 hubs

Six Module Enclosures - 6 hubs

Battery back-up Enclosure - 2 hubs

Sensor/Transmitter Enclosure - 1 hub

Conduit hubs are installed in any enclosure knockout labeled PG16. Note that some knockouts have more than one designation, such as PG11/16. Those with two designations will have concentric circles for knockouts. The inner circle marks the lower PG number while the outer circle marks the higher number. Place a thin bladed screwdriver into the circular slot or the desired knockout size and tap firmly with a hammer. To install the hub, place the seal ring over the threaded part of the hub. Locate the hub nut on the inside of the enclosure and screw the hub into the hub nut from the outside. Tighten firmly to insure that the seal ring provides a good seal between the hub and the outside of the enclosure.

O & M Manual

Rev-P (7/15) 7

ATI

B14 Alarm System Section 2 – Mechanical Installation

For installations where conduit will not be used, cable gland seal fittings must be installed in the conduit hubs. Plastic cable glands are available from most electrical supply stores. Gland seals with ½”

NPT threads will screw directly into the conduit hub. Gland seals are also available from ATI for installation directly into the enclosures in place of the conduit hubs. Refer to the parts list for the correct part number of the cable gland seals.

Figure 1 - Single Module System Enclosure Dimensions (80-0005)

O & M Manual

Rev-P (7/15) 8

ATI

B14 Alarm System

FRONT VIEW

Section 2 – Mechanical Installation

SIDE VIEW

THRU HOLES FOR SURFACE

MOUNTING (4) #6 SCREWS

BOTTOM VIEW

Figure 2 - Two Module System Enclosure Dimensions (80-0006)

O & M Manual

Rev-P (7/15) 9

ATI

B14 Alarm System

FRONT VIEW

Section 2 – Mechanical Installation

SIDE VIEW

THRU HOLES FOR SURFACE

MOUNTING (4) #6 SCREWS

BOTTOM VIEW

Figure 3 - Three Module System Enclosure Dimensions (80-0007)

O & M Manual

Rev-P (7/15) 10

ATI

B14 Alarm System Section 2 – Mechanical Installation

Figure 4 - Six Module System Enclosure Dimensions (80-0008)

O & M Manual

Rev-P (7/15) 11

ATI

B14 Alarm System Section 3 – Electrical Installation

ELECTRICAL INSTALLATION

Field wiring required for a detection system includes connection of AC power, connection of two conductor cable between the receiver and the sensor/transmitter, and connection of the battery back-up unit if it was purchased with the system. ATI does not supply an AC power cord with the system. A 25 foot length of 2 conductor interconnect cable is supplied for connection of the sensor/transmitter to the receiver. Longer lengths up to 1000 feet may be used when required.

Single point detection systems are supplied with the power supply, receiver, and optional horn factory wired as shown in Figure 5 below.

Analytical Technology, Inc.

Figure 5 - Single Point Receiver Internal Wiring (ATI-0172)

Figure 18 on page 24 of this manual shows a detailed terminal wiring drawing for the Receiver module. Figure 20 on page 36 shows a detailed terminal wiring drawing for the Power supply module.

A B14 gas detection system will always contain a B14 Receiver and either a B12

Sensor/Transmitter, or an A12 UniSens 2-Wire Transmitter. Normally, an A17 Power supply module will also be included, and an A19 Battery Back-up Unit will often be used to provide standby power for the system. Figures 8 and 9 provide interconnecting wiring diagrams for a typical single channel system connected to a B12 Sensor/Transmitter. Figure 13 provides an interconnect wiring diagram for a typical single channel system connected to an A12 2-Wire Transmitter.

O & M Manual

Rev-P (7/15) 12

ATI

B14 Alarm System Section 3 – Electrical Installation

Two point detectors include one power supply and two receivers. These systems are shipped factory wired as shown in Figure 1-6 below.

Analytical Technology, Inc.

Figure 6 - Dual Point Receiver Internal Wiring (ATI-0173)

O & M Manual

Rev-P (7/15) 13

ATI

B14 Alarm System Section 3 – Electrical Installation

Analytical Technology, Inc.

Analytical Technology, Inc.

Figure 7 - Four Point Receiver Internal Wiring (ATI-0174)

O & M Manual

Rev-P (7/15) 14

ATI

B14 Alarm System Section 3 – Electrical Installation

Figure 8 - Receiver Connection to 65W Power Supply (ATI-0545)

O & M Manual

Rev-P (7/15) 15

ATI

B14 Alarm System Section 3 – Electrical Installation

Sensor/transmitters contain a terminal block for receiver connection. Connection of the two wires from the receiver is not polarity sensitive. These wires can be connected without regard to terminal position. Multi-channel systems will duplicate the 2 conductor cable wiring between the Receiver and

Sensor/Transmitter.

Analytical Technology, Inc.

Figure 9 - Typical System Wiring, Nemz-4 Transmitter Version (ATI-0175)

CAUTION: Be very careful when removing the knockouts on the sensor/transmitter enclosure. A small bladed screwdriver tapped firmly in the knockout recess is all that is necessary. Do not drive the screwdriver blade into the transmitter enclosure or it may strike the circuit board and cause component damage.

O & M Manual

Rev-P (7/15) 16

ATI

B14 Alarm System Section 3 – Electrical Installation

Analytical Technology, Inc.

Figure 10 - Typical System Wiring, Explosion-Proof B12 Sensor/Transmitter (ATI-0176)

O & M Manual

Rev-P (7/15) 17

ATI

B14 Alarm System Section 3 – Electrical Installation

Analytical Technology, Inc.

Figure 11 - Typical System Wiring, B12-17 Combustible Sensor/Transmitter (ATI-0215)

O & M Manual

Rev-P (7/15) 18

ATI

B14 Alarm System Section 3 – Electrical Installation

Analytical Technology, Inc.

LEL Transmitter

Figure 12 - Typical System Wiring, C12-17 Combustible Sensor/Transmitter (ATI-0609)

O & M Manual

Rev-P (7/15) 19

ATI

B14 Alarm System Section 3 – Electrical Installation

Analytical Technology, Inc.

Figure 13 - Typical System Wiring, A12 2-Wire Transmitter (ATI-0179)

O & M Manual

Rev-P (7/15) 20

ATI

B14 Alarm System Section 3 – Electrical Installation

Analytical Technology, Inc.

Figure 14 - Typical System Wiring, A12-17 Combustible Transmitter (ATI-0355)

The remainder of this manual is divided into sections that describe each component of the system.

Mechanical and electrical installation are the only requirements to provide a workable system. Power supply modules and battery back-up units require no adjustments. Receiver modules are factory set to the range specified on the order, and alarm setpoints will be set to default values unless otherwise specified on the order. Sensor/transmitters are factory calibrated, and should require no adjustments when placed in service. Calibration can be checked if desired according to the instructions in the

Sensor/transmitter section of this manual.

Normal operation of the system uses the switch on the Receiver module. The “Operation” portion of the

Receiver section (section 2) should be read and understood before placing the detection system into operation.

O & M Manual

Rev-P (7/15) 21

ATI

B14 Alarm System Section 3 – Electrical Installation

Analytical Technology, Inc.

Figure 15 - Typical System Wiring, D12 Transmitter (2-Wire Hookup) ( ATI-0610)

O & M Manual

Rev-P (7/15) 22

ATI

B14 Alarm System Section 3 – Electrical Installation

Analytical Technology, Inc.

Figure 16 - Typical System Wiring, D12 Transmitter (3-Wire Hookup) (ATI-0611)

O & M Manual

Rev-P (7/15) 23

ATI

B14 Alarm System Section 4 – Receiver Module

B14 RECEIVER MODULE

Series B14 Receivers provide alarm relay and display functions for the gas detection system. Each receiver is connected to one 2 or 3 wire sensor/transmitter, and displays information on the gas concentration in the sensor area. Receivers are powered by a separate 12 VDC power supply (part no.

00-0055) supplied as part of the system, or by a power supply furnished by the user (12-28 VDC only.

Figure 17 - Front Panel Controls & LEDs (ATI-0177)

Receiver modules also include the following standard features:

1. Three SPDT alarm relays, switch programmable for operating configuration.

2. One SPDT trouble relay, for remotely indicating that the TROUBLE alarm is activated.

3. Isolated 4-20 mA output signal proportional to gas concentration.

4. Isolated remote reset input terminals for remote alarm acknowledgment.

5. 24 VDC power for operation of either 2 or 3 wire transmitters.

Receivers are housed in a compact polystyrene case designed for mounting to a 35 x 7.5 mm DIN rail. The rails are supplied in standard ATI system enclosures, or can be supplied by a system integrator as part of a custom panel arrangement. A spring clip on the back of the enclosure holds the module to the rail. To remove from a rail, slide a thin bladed screwdriver through the black loop at the top of the module and pull outward until the module releases from the rail. To mount to the rail, reverse the procedure. When mounting, slide the bottom of the module against the bottom of the rail before extending the spring clip.

Electrical Connection

Electrical connections to the receiver are made to two pluggable terminal blocks as shown in Figure

18. Transmitter connections must be made at the time of installation, while power and horn connections are factory wired when the receiver is part of a complete system. Connections should be made and checked before power is applied to the module. Never connect or alter connections while power is on.

O & M Manual

Rev-P (7/15) 24

ATI

B14 Alarm System Section 4 – Receiver Module

1:

6:

7:

8:

9:

2:

3:

4:

5:

10:

11:

12:

POWER Vin +

TB1

POWER Vin -

Earth Ground (REQUIRED)

H+ Audible Horn positive

H- Audible Horn negative

RR Remote Reset

RR Remote Reset

MA+ 4-20 mA output positive

MA- 4-20 mA output negative

+24 24V Loop Supply

SIG Milliamp (+) Input

Ground Milliamp (-) Input

1:

6:

7:

8:

9:

2:

3:

10:

11:

12:

TB2

A1 NO Alarm 1 normally open contact

A1 C Alarm 1 common

A1 NC Alarm 1 normally closed contact

4:

5:

A2 NO Alarm 2 normally open contact

A2 C Alarm 2 common

A2 NC Alarm 2 normally closed contact

A3 NO Alarm 3 normally open contact

A3 C Alarm 3 common

A3 NC Alarm 3 normally closed contact

TROUBLE NC Trouble normally closed contact

TROUBLE C Trouble common

TROUBLE NO Trouble normally open contact

NOTE: Relay contact designation is shown for relays in normal mode of operation for relays A1, A2, A3. If fail-safe relay operation is selected, NO and NC designations are reversed for that relay. The TROUBLE relay is set to fail-safe operation at the factory, and the designation shown above is for the trouble relay in fail-safe mode.

Figure 18 - Receiver Module Terminals (ATI-0178)

CAUTION: Receiver modules MUST be connected to a secure earth ground. Terminal 3 of TB1 in

Figure 18 above must be connected to the earth ground terminal of ATI’s power supply module as shown in the connection diagram in Figure 19. If the user is providing another power supply, be sure that the receiver is properly grounded.

O & M Manual

Rev-P (7/15) 25

ATI

B14 Alarm System

Factory Configuration

Section 4 – Receiver Module

All receivers are identical except for the gas symbol attached to the green power LED. Operating range, alarm relay configuration, and Fail setpoint are selectable using 6 banks of DIP switches located on the configuration circuit board inside the module.

Receivers are factory configured for the operating range specified on the customer order. Factory configuration of the relays is as follows:

Relay 1 - Configured to trip at the Caution setpoint (10% of Full Scale) and set for normal, non-

latching operation.

Relay 2 - Configured to trip at the Warning setpoint and set for normal, non-latching operation.

Relay 3 - Configured to trip at the Alarm setpoint and set for normal, latching operation.

Alarm Delay - Configured for 2 second delay.

Caution, Warning and Alarm setpoints are factory set to standard values depending on the operating range. Except for oxygen systems, alarms are set to activate above the setpoints. Oxygen alarms are set to activate below the setpoints. Each alarm relay may be configured to activate either above or below the setpoint through proper DIP switch selection.

O & M Manual

Rev-P (7/15) 26

ATI

B14 Alarm System Section 4 – Receiver Module

Configuration Switches

Figure 19 indicates the location of each bank of DIP switches labeled S1 thru S6 on the configuration

P.C. board and Table 2-1 below, provides a description of the function of each switch on each bank.

TABLE 2-1

Bank A (S1) - Range

1 2

0=no

1=yes

Blanking enabled

0=no

1=yes

Horn on

Trouble

Bank B (S2) - Caution

1

0=above

1=below trip direction

2 bit6

Bank C (S3) - Warning

3

0=2 Sec.

1=10 Sec.

CWA delay

3 bit5

4 bit4

4 bit4

5 bit3

5 bit3

Caution setpoint

(% of full scale)

6 bit2

Operating Range

(see chart)

6 bit2

7 bit1

7 bit1

8 bit0

8 bit0

4 bit4

5 bit3

6 bit2

7 bit1

8 bit0

1

0=above

1=below trip direction

2 bit6

Bank D (S4) - Alarm

1 2

0=above

1=below trip direction bit6

Bank E (S5) - Relay Options

3 bit5

3 bit5

1

00=Caution

01=Warning

10=Alarm

11=Horn

2 3

0=NonLat.

1=Latching

Relay 1 (A1) definition

Bank F (S6) - Relay Options

1

00=Caution

01=Warning

10=Alarm

11=Horn

2 3

0=NonLat.

1=Latching

Relay 3 (A3) definition

4 bit4

4

0=Normal

1=FailSafe

4

0=Normal

1=FailSafe

Warning setpoint

(% of full scale)

5 bit3

Alarm setpoint

(% of full scale)

6 bit2

5 6

00=below 3.7mA (-1.9%)

01=below 3.1mA (-5.6%)

10=below 2.4mA (-10%)

11=none

Trouble detection

7 bit1

5

00=Caution

01=Warning

10=Alarm

11=Horn

6 7

0=NonLat.

1=Latching

Relay 2 (A2) definition

7

0=NonLat.

1=Latching

8 bit0

8

0=Normal

1=FailSafe

8

0=Normal

1=FailSafe

Relay 4 (Trouble) definition

O & M Manual

Rev-P (7/15) 27

ATI

B14 Alarm System Section 4 – Receiver Module

Figure 19 - Configuration Board Switch Location

Operating Range Chart

TABLE 2-2

Operating

Range

0 - 1.00

0 - 2.00

0 - 3.00

0 - 4.00

0 - 4.0

0 - 5.0

0 - 10.0

2.0 - 12.0

0 - 14.0

0 - 20.0

0 - 25.0

0 - 30.0

0 - 50

0 - 100

0 - 200

0 - 300 bits

43210

00000

00001

00010

00011

00100

00101

00110

00111

01000

01001

01010

01011

01100

01101

01110

01111

Operating

Range

0 - 500

0 - 1000

0 - 1000 LSD Fixed

0 - 2000

0 - 2000 LSD Fixed

0 - 3000

0 - 3000 LSD Fixed

0 - 5000

0 - 5000 LSD Fixed

0 - 5.00

0 - 25.0 Oxygen (O

2

)

0 - 1.00 LSD Fixed

Reserved

Display reads ‘ -- ‘

4.0 - 20.0 bits

43210

10000

10001

10010

10011

10100

10101

10110

10111

11000

11001

11010

11011

11100

11101

11110

11111

O & M Manual

Rev-P (7/15) 28

24

25

26

27

28

29

30

31

32

17

18

19

20

21

22

23 disable d

5

6

7

8

9

10

11

12

13

14

15

16

33

34

35

36

ATI

B14 Alarm System Section 4 – Receiver Module

Setpoint Selection

The operating range and the Caution, Warning and Alarm setpoints can be changed, if desired, by using the configuration switches identified in Table 2-1 on page 2-5. The Caution setpoint is set using switches B2-B8 labeled (S2), the Warning setpoint is set using switches C2-C8, labeled (S3) and the

Alarm setpoint is set using switches D2-D8, labeled (S4). A binary number is used to select setpoints as a percent of operating range. For example, if you have a receiver range of 0-10 PPM and want to adjust a setpoint for 3 PPM, set the appropriate DIP switches to the binary number for 30% from Table 2-3 below. Switches can be set using a tool with a small point on one end. Viewed with the switch in the vertical position as shown in Figure 19, a switch to the left side indicates ‘on’ or a value of ‘1’ and to the right indicating ‘off’ or a value of ‘0’. Caution, Warning, and Alarm can be disabled by setting switches 2-8 of the corresponding bank to the ‘OFF’ position.

TABLE 2-3

% SWITCH POS. % SWITCH POS. % SWITCH POS.

0000000

0010101

0010110

0010111

0011000

0011001

0011010

0011011

0011100

0011101

0011110

0011111

0100000

0100001

0100010

0100011

0100100

0000101

0000110

0000111

0001000

0001001

0001010

0001011

0001100

0001101

0001110

0001111

0010000

0010001

0010010

0010011

0010100

1010101

1010110

1010111

1011000

1011001

1011010

1011011

1011100

1011101

1011110

1011111

1100000

1100001

1100010

1100011

1100100

1000101

1000110

1000111

1001000

1001001

1001010

1001011

1001100

1001101

1001110

1001111

1010000

1010001

1010010

1010011

1010100

93

94

95

96

97

98

99

100

85

86

87

88

89

90

91

92

76

77

78

79

80

81

82

83

84

69

70

71

72

73

74

75

0110101

0110110

0110111

0111000

0111001

0111010

0111011

0111100

0111101

0111110

0111111

1000000

1000001

1000010

1000011

1000100

0100101

0100110

0100111

0101000

0101001

0101010

0101011

0101100

0101101

0101110

0101111

0110000

0110001

0110010

0110011

0110100

61

62

63

64

65

66

67

68

53

54

55

56

57

58

59

60

44

45

46

47

48

49

50

51

52

37

38

39

40

41

42

43

O & M Manual

Rev-P (7/15) 29

ATI

B14 Alarm System Section 4 – Receiver Module

Range Selection

Display range selection sets the full scale operating range of the receiver. Table 2-2 on page 2-6, provides the proper switch settings for the ranges available on each receiver. Range selection is made using switches A4-A8, labeled (S1). The 4-20 mA output signal is proportional to the selected range.

Ranges marked with ‘LSD Fixed’ indicate that the least significant digit on the display always reads zero.

Relay Configuration

Receivers contain 3 SPDT alarm relays that actuate based on gas concentration. Alarm setpoint relays can be set to actuate when the gas concentration either goes above or falls below the setpoint.

Most gas leak detection applications require alarms to activate above a specific setpoint, but alarms for oxygen deficiency require relay actuation below the setpoints. Each contains a switch that selects whether that activates above or below the setpoint. Switch B1 labeled (S2), controls Caution, switch C1, labeled (S3) controls Warning, and switch D1 labeled (S4), controls Alarm as shown in Figure 19 on page

27.

Each relay can be assigned to the caution, warning or alarm setpoint. As shown in Figure 19, switches E1-2, E5-6, labeled (S5), and F1-2 labeled (S6), can be used to assign the relays to a particular setpoint. When caution is selected, the relay will activate when the caution lamp on the front panel lights.

When warning is selected, the relay will activate when the warning lamp on the front panel lights. When alarm is selected, the relay will activate with the alarm lamp on the front panel.

Relays may be either Latching or Non-latching. A latching relay activates when gas concentration exceeds the setpoint, but will only deactivate when the A/R button is pressed, and then only if the gas concentration has fallen below the setpoint. A non-latching relay will automatically deactivate when the gas concentration falls below the setpoint without A/R button being pressed. Selection of the latch/nonlatch function uses switches E3, E7, labeled (S5), F3, and F7 labeled (S6).

Relays may be configured for either Fail-safe or Normal operation. The designation of normal or failsafe refers to the operation of the relay coil during normal operation. A relay configured for Normal operation will have the relay coil energized when an event occurs and de-energized during normal operation. A relay configured for Fail-safe operation has the relay coil energized when conditions are normal and de-energizes when an event occurs. A fail-safe relay will change state if power to the receiver is interrupted. Selection of the fail-safe function uses switches E4, E8, labeled (S5), F4, and F8 labeled (S6).

A short time delay precedes the activation of caution, warning, and alarm relays when a setpoint is exceeded. This brief delay of 2 seconds eliminates false alarms due to transients that might be encountered in a particular installation. The 2 second delay is the factory default and is selected with switch A3 labeled (S1). A 10 second delay may be selected if required in a specific application. The delay time of either 2 or 10 seconds affects the caution, warning, and alarm lamps and their associated relays.

O & M Manual

Rev-P (7/15) 30

ATI

B14 Alarm System Section 4 – Receiver Module

External Horn Relay

Relays in the B14 receiver provide an additional configuration option for external horn activation.

Switches E1-2, E5-6 labeled (S5), and F1-2, labeled (S6), allows relays to be configured for “HORN” mode of operation. When a relay is configured for this mode, it will operate in parallel with the internal horn. This means that any external horn tied to that relay will sound intermittently when the warning setpoint is exceeded or trouble is detected and will go to steady on when the alarm setpoint is exceeded.

The relay will deactivate when the A/R switch is pressed, silencing the external horn. Neither the internal or an external horn will sound when the caution setpoint is reached.

Using a relay in the horn configuration eliminates the need for additional relay logic to silence an external horn. This can provide significant cost savings in the installation of a complete alarm system.

O & M Manual

Rev-P (7/15) 31

ATI

B14 Alarm System Section 5 – Receiver Operation

OPERATION

Receiver front panels contain four LED bar indicators and a 4 digit LED display. The digital display indicates gas concentration in either PPM, PPB, or percent. The green LED bar is marked with the gas symbol and units of measurement (PPM, PPB, % or % LEL) specified on the customer order. LED bars also indicate CAUTION, WARNING, and ALARM conditions.

When power is first applied, the LED display will turn on and will step through four information displays. The first number displayed is the full scale range. A 0-10 PPM unit will be indicated by “10.0” on the display. After 3 seconds, the display will indicate the caution setpoint, with the CAUTION lamp illuminated. After 3 seconds, the display will indicate the warning setpoint, with the WARNING lamp illuminated. After 3 seconds, the display will indicate the alarm setpoint, with the ALARM lamp illuminated. After 3 seconds, the display will indicate the software revision level, (r x.x). At the end of this sequence, the display will begin to indicate gas concentration. However, all alarm functions and 4-20mA output will be inhibited for 5 minutes while the system is allowed to stabilize. This is indicated by

CAUTION, WARNING and ALARM lamps flashing in an sequential pattern. During this period, alarms will not function, but the display will indicate the presence of any gas that might be in the area of the sensor.

Normally, the display will spike when power first comes on, and will slowly recover to zero over the 5 minute period in which alarms and 4-20mA output are inhibited. The 5 minute inhibit can be bypassed by pressing the A/R switch at any time during the inhibit time-out.

Alarm Acknowledge and Reset

The front panel of the receiver contains one button, marked A/R , which is used for a number of different functions. When the receiver is in normal operation, a gas leak that exceeds the caution setpoint will cause the CAUTION indicator to flash. Any relays assigned to caution will activate. Pressing the A/R button will change the indicator to a steady on indication. Exceeding the warning setpoint will cause the

WARNING indicator to flash and the internal horn to sound intermittently. If the alarm setpoint is exceeded, the ALARM indicator will flash and the horn will sound steadily. Pressing the A/R button the first time will silence the audible horn, and will change the WARNING and ALARM indicators from flash to steady on. The indicator lamps will remain lit until the gas condition has cleared. The CAUTION and

WARNING indicators will automatically shut off when gas concentration falls below the setpoint, but the

ALARM indicator will remain lit. Pressing the button after the alarm condition has cleared will reset the

ALARM indicator.

Operation of the individual relays depends on the configuration selected for each one. As shipped from the factory, relay A1 will energize when the CAUTION indicator lights and will automatically reset when the gas condition clears and the CAUTION indicator shuts off. Relay A2 will energize when the

WARNING indicator lights and will automatically reset when the gas condition clears and the WARNING indicator shuts off. Relay A3 will energize and latch when the ALARM indicator lights. This relay will reset when the A/R button is pressed to reset the ALARM indicator. Changes in the relay configuration switches will alter this operational sequence.

O & M Manual

Revision N, 12/06 32

ATI

B14 Alarm System Section 5 – Receiver Operation

Trouble Alarm and Relay

Receivers contain a TROUBLE indicator and an associated SPDT relay. The trouble alarm will be activated if the 4-20 mA input falls below a preset limit. If this condition occurs, the POWER lamp will flash, the horn will sound intermittently, and the trouble relay will change state. The TROUBLE relay can be configured to be latching (F7) and failsafe (F8). The horn function associated with the trouble alarm can be deactivated by changing the position of switch A2 (see Table 2-1) on page 2-5.

The setpoint for the trouble detection circuit can be selected for values below 3.7 mA, below 3.1 mA, below 2.4 mA, or turned off completely. This is done using switches F5-6, labeled (S6). ATI series A12 transmitters operate between 4 and 20mA and provide an output of 3.0 mA on trouble, so the below 3.1 mA configuration should be used. Series B12 transmitters operate between 4 and 20mA, do not have a trouble output, but can go under range to 3.6mA with large sensor offsets, so a configuration of below 3.1 mA should also be used for this type of input. In each case, a break in the loop wiring will cause a trouble alarm. If another brand of transmitter is connected to a B14 receiver, contact the transmitter manufacturer for information on available trouble signals.

Lamp and Horn Test

Verification that all display segments and alarm indicator bars are functional is done using the A/R button to initiate a lamp test. If the detection system includes an internal horn, the horn is also tested as part of the lamp test.

To activate the lamp test, press and hold the A/R button for approximately 3 seconds and all front panel indicators will light. The horn will also sound briefly. Immediately release the button and the indicators will return to normal.

The operating range, caution, warning, and alarm setpoints can be displayed at the end of this test.

See the Inhibit Mode section below.

Inhibit Mode

Alarm relays and 4-20mA output in the receiver can be inhibited for up to 4 hours to allow calibration or testing of sensor/transmitters without activating external alarm or control devices. Alarm inhibit is activated through the use of the A/R button.

Press and hold the button for approximately 3 seconds. The lamp test will occur first, but continue to hold the button down. Once the lamps have shut off, release the button. The CAUTION, WARNING and

ALARM lamps will begin a sequential pattern. If the A/R button is pressed and released, the receiver will go into the inhibit mode (if a horn is connected, a quick beep will sound when the inhibit is selected). If the button is not pressed within 5 seconds, the unit will display the operating range, caution setpoint, warning setpoint, alarm setpoint, and software revision level, then revert to the normal operating mode.

The CAUTION, WARNING and ALARM lamps will continue their sequential flash, and will continue for 4 hours or until the A/R button is pressed again. During this period, the display will indicate gas concentration, but the relays will not activate and the 4-20mA output will not change. Transmitters may be calibrated while the inhibit is on without activating external alarms.

O & M Manual

Revision N, 12/06 33

ATI

B14 Alarm System Section 5 – Receiver Operation

Remote Reset

Receivers are provided with input terminals for connection of a remote reset switch. The remote reset input provides horn silence and alarm reset functions using a switch located at a remote point.

When receivers are located at sites with telemetry equipment, the remote reset input may be connected to a relay contact in the telemetry system.

The remote reset input accomplishes the same acknowledge and reset functions as the A/R button on the front panel. When a switch closure is detected across the remote reset terminals, the detector horn will silence and any latching relays will reset, provided that the gas condition has cleared. The remote reset input will not activate any of the testing or inhibit functions of the receiver.

Analog Output

Receivers provide an isolated 4-20 mA output signal for interface with recorders, data loggers, or computer systems. The span of the 4-20 mA signal is the same as the range of the receiver selected during the receiver configuration. The output will drive loads up to 1200 ohms. On trouble condition, the output signal will go to 3mA until the condition is cleared and the trouble alarm is acknowledged.

In Inhibit Mode, the output signal is held at 4mA for all gases except oxygen (range dip switches A4-

A8 set for ‘11010’) where the signal is held at 17.4mA (20.9% O

2

).

Troubleshooting

Receiver modules will normally provide trouble free operation over many years of service. However, should problems arise, a few simple tests can be done to determine if the receiver is functioning properly.

LED display and green gas indicator do not light when power is applied to the system.

1. Check polarity of the power connection at terminals 1 and 2 of TB1. Terminal 1 must be and terminal 2 must be negative. positive

2. With a voltmeter, check the power supply at terminals 1 and 2 of TB1. Input power supply must be between 12 and 28 VDC.

Receiver module powers up correctly, but does not respond when test gas is applied to sensor/transmitter.

1. Check the voltage on 10 and 12 terminals of TB1 with a voltmeter. The voltage should be about

24 VDC.

Problems in the receiver module can only be caused by an electronic component failure. In most cases, the simplest solution is to remove the module and install a replacement. Troubleshooting the electronic circuit boards is best handled by trained technician familiar with the circuits. As modules are small and easily shipped, it is best to return defective modules to ATI for service.

Modules failing during the warranty period will be exchanged by ATI with replacement units.

Contact the ATI service department for assistance.

O & M Manual

Revision N, 12/06 34

ATI

B14 Alarm System

RECEIVER MODULE PARTS LIST

PLUG-ON TERMINAL BLOCK

(38-0006)

TOP HALF OF

ENCLOSURE

(80-0002)

PC BOARD ASSEMBLY

FRONT PANEL, (34-0087)

Section 5 – Receiver Operation

BOTTOM HALF OF ENCLOSURE

(80-0002)

PLUG-ON TERMINAL BLOCK

(38-0009)

Part Number

00-0507 *

03-0113

80-0002

34-0087

38-0009

38-0006

Description

Complete receiver module

Printed circuit board assembly

Module enclosure (top and bottom)

Front panel

Relay terminal block plug, 12 position

DC terminal block plug, 12 position

Items marked with an asterisk (*) are recommended spares.

O & M Manual

Revision N, 12/06 35

ATI

B14 Alarm System Section 6 – Power Supply Module

UNIVERSAL POWER SUPPLY

The power supply module used in the B14 system (part #00-0055) is a self-adjusting supply that will accept the AC power provided in virtually every country in the world. Any AC (50-60 Hz.) or DC voltage from 85 volts to 270 volts can be connected to the power input terminals on TB 4. There are no adjustments of any kind required.

The output of the power supply is a regulated 13.7 VDC. There are 3 sets of DC terminals at the top of the module for connection to receivers and external battery back-up units. This voltage permits float charging of a separate 12 volt lead acid battery for detector system back-up.

Power supply modules are rated for 1 ampere output, and will deliver higher current for short periods.

Each receiver module draws a maximum of approximately 300 mA, and will normally draw about 125 mA.

An external battery back-up unit can draw up to 750 mA for a few hours if the battery is deeply discharged, but the current draw drops sharply as the battery approaches full charge. The audible horn draws less than 10 mA average current, and an optional strobe will draw approximately 400 mA when activated.

The power supply is internally fused at 2 amps. The fuse is not user replaceable. (note: Only qualified service personnel will replace the fuse, using the same type and rating as indicated on the fuse).

The power supply has a power-on indicator LED and provides a SPDT relay to indicate power failure. The relay coil is energized by power from the primary (TB5) terminals and will de-energize if primary power is lost. This relay is convenient for input to telemetry systems to indicate loss of primary power at a remote site.

Mounting of power supply modules is done by clipping them to a standard 35 x 7.5 mm DIN rail. A spring loaded clip holds the module to the rail and is used for mounting and removal. From the front, the clip is seen as a black loop at the top rear of the module. To remove from a rail, place a small screwdriver into the opening in the black loop and pull outward until the module releases from the rail.

Reverse the procedure to mount the module.

CAUTION

The power supply module is sealed, and the seal should not be broken. Never attempt to disassemble or service the power supply module. Service on this module should only be done only by a qualified service technician familiar with the circuit design and equipped with the proper service equipment. Severe electrical shock or death may result from touching internal components with input power applied.

O & M Manual

Revision N, 12/06 36

ATI

B14 Alarm System Section 6 – Power Supply Module

Figure 20 provides detailed information on the terminals provided on the power supply. All terminal blocks are plug-in type, and can be easily unplugged should removal of the module be necessary.

TB1

(12V Battery only)

1: +12 External Battery (+)

2: C External Battery (-)

TB2

1: +12 Receiver Module (+)

2: C Receiver Module

Common

3: Earth Ground

TB3

1: +12 Receiver Module (+)

2: C Receiver Module Common

3: Earth Ground 3: Earth Ground

TB4 TB5

1: L AC power hot (85-255 VAC)

2: N AC power neutral

1: NC Power failure normally closed contact

2: C Power failure common

3: AC power ground (earth ground REQUIRED) 3: NO Power failure normally open contact

NOTE: AC power input must be properly earth grounded for safe operation. 220 VAC power without a neutral line may not be used with this power supply.

Figure 20 - Power Supply Terminal Connections (ATI-030)

O & M Manual

Revision N, 12/06 37

ATI

B14 Alarm System

POWER SUPPLY PARTS LIST

Section 6 – Power Supply Module

Part Number

00-0055 *

01-0010

81-0046

34-0011

38-0065

38-0066

80-0011

Description

Complete power supply module

Power supply circuit board assembly

Module enclosure (top and bottom)

Front Overlay

AC power terminal block plug, 3 position

Power failure relay & DC terminal block plug, 3 position

Front Cover

Items marked with an asterisk (*) are recommended spares.

O & M Manual

Revision N, 12/06 38

ATI

B14 Alarm System Section 6 – Accessory Items

BATTERY BACK-UP UNIT

Battery back-up units for B14 detection systems (part #00-0057) are separate components housed in a NEMA 4X wall mount enclosure. Back-up units include a 4 ampere-hour sealed lead acid battery with a control circuit attached to the battery terminals. The battery is held in place on an aluminum bracket fixed to the plastic enclosure.

Installation

Figure 21 shows the dimensions of the battery back-up unit and the mounting hole centers. Two conduit hubs are supplied with the unit, one for use on the battery back-up enclosure and one for use on the receiver enclosure. When mounting the battery back-up unit, be careful to hold the module securely when screwing the enclosure in place. The battery is heavy and could cause injury to feet if it should fall directly on them.

The battery and attached circuit board are held in place with a wire tie. Should you wish to remove the battery, the wire tie must be cut. When replacing the battery, secure with a new wire tie. Replacement batteries from ATI are supplied with the proper wire tie.

FRONT VIEW SIDE VIEW

THRU HOLES FOR SURFACE

MOUNTING - (4) #6 SCREWS

BOTTOM VIEW

Figure 21 - Battery Back-up Mounting Dimensions

O & M Manual

Revision N, 12/06 39

ATI

B14 Alarm System Section 6 – Accessory Items

Electrical connection is made between the battery back-up unit and the power supply module. The circuit board mounted on the battery contains a 2 position plug-in terminal block marked plus and minus.

The plus terminal is connected to terminal B+ of the power supply and the minus terminal is connected to

B- of the power supply.

Operation

When power is applied to the power supply module, a relay on the battery back-up circuit board energizes and places the battery back-up into operation. There are no user adjustments in the battery back-up unit. If the battery is not fully charged, the power supply will begin supplying charge current to the battery, and will float charge the battery as long as the power supply is on.

Should the power supply loose its input power, the battery back-up will immediately supply power to receiver modules to maintain detection system operation without interruption. The back-up period will vary depending on whether the detector is single channel or two channel, and on how many relays are configured for fail-safe operation. The minimum period expected for a single channel system is 12 hours and for a two channel system is 6 hours. Normally, the back-up period is twice as long as the minimums.

The circuit board attached to the battery serves two functions. First, it regulates the charging current to the battery to a maximum of 0.75 amps. This prevents possible damage to the battery due to an excessively high charge current. Second, it isolates the battery from the detection system when the battery voltage falls below 10 volts. This is done through a relay, and protects the battery against damage caused by very deep discharge.

The isolation relay that protects against deep discharge will also protect the battery against an external short circuit of the wires connected to the battery. If a short occurs, the relay will immediately open, protecting the battery and limiting the current that the battery will deliver.

Removal from Service

The relay that isolates the battery when the 10 volt level is reached is energized as soon as power is applied to the power supply module. Once energized, the coil current is supplied from the battery if needed. If the gas detection system supported by the battery back-up is started up for testing and then shut down, the battery back-up relay should be de-energized manually. Otherwise, the relay coil will continue to draw power from the battery until the 10 volt level is reached. While this will not cause damage, it means that the battery will be discharged when the detection system is started up again.

To de-energize the relay, slide the control circuit board off the battery terminals briefly and then slide it back on. As soon as the battery connection is broken, the relay coil will drop out, and will not energize until power is applied to the power supply module in the system. This procedure is recommended any time the detection system is to be shut down for more that a few days.

O & M Manual

Revision N, 12/06 40

ATI

B14 Alarm System

BATTERY BACK-UP PARTS LIST

ENCLOSURE (80-0009)

BATTERY BRACKET (48-0010)

(2) SELF-TAPPING SCREWS

TIE WRAP (44-0026)

BATTERY (29-0002)

PC BOARD (01-0011)

TERMINAL BLOCK PLUG (38-0002)

ENCLOSURE LID

Section 6 – Accessory Items

Part Number

00-0057

01-0011

80-0009

48-0010

29-0002

41-0011

44-0017

Description

Complete battery back-up unit

Battery back-up circuit board

NEMA 4X enclosure (top and bottom)

Battery bracket

Battery, 12 V, 4 A-H

Self-tapping screws

1/2” NPT conduit hub

O & M Manual

Revision N, 12/06 41

ATI

B14 Alarm System Section 6 – Accessory Items

STROBE LIGHT

The accessory alarm indicating strobe light (part number 35-0002) available for use with the B14 alarm system is a weatherproof high-intensity strobe operating from a 12-80 VDC power source. The strobe can be conveniently mounted on the top or either side of the alarm enclosure using one of the ½”

NPT hubs supplied with the unit. The bottom of the strobe also contains a ½” NPT mounting adapter, so that only a ½” pipe nipple is needed to complete the assembly. The necessary nipple is available from most hardware stores or plumbing supply outlets.

For remote applications, the strobe should be mounted to ½” conduit, with a junction box nearby for splicing the strobe wires to the interconnect wiring running to the alarm unit. This wiring should be kept separate from AC power wiring to avoid accidental connection of AC power to the strobe, which will damage the lamp.

The power to operate the strobe can be picked up from the power supply module which is part of the alarm unit. Figure 22 shows the typical wiring diagram for connection of the strobe. The wiring diagram shows the plus side of the supply brought to the common of the alarm contact, one side of the strobe wired to the normally open (NO) contact, and the other side of the strobe connected to the minus side of the supply. Connection of the strobe lamp directly across the alarm relay will not operate the strobe because alarm contacts are unpowered.

CAUTION: Strobe light connection is polarity sensitive. Check wiring to be sure that the + power supply terminal is connected to the red strobe wire.

Analytical Technology, Inc.

Figure 22 - External Strobe Light Connections (ATI-0202)

O & M Manual

Revision N, 12/06 42

ATI

B14 Alarm System

STROBE PARTS LIST

Strobe p/n Strobe Description

35-0002

35-0005

35-0004

35-0006

Red Strobe, 12-80 VDC

Red Strobe, 120 VAC

Amber Strobe, 12-80 VDC

Amber Strobe, 120 VAC

Section 6 – Accessory Items

O & M Manual

Revision N, 12/06 43

PRODUCT WARRANTY

Analytical Technology, Inc. (Manufacturer) warrants to the Customer that if any part(s) of the Manufacturer's equipment proves to be defective in materials or workmanship within the earlier of 18 months of the date of shipment or 12 months of the date of startup, such defective parts will be repaired or replaced free of charge. Inspection and repairs to products thought to be defective within the warranty period will be completed at the Manufacturer's facilities in Collegeville, PA. Products on which warranty repairs are required shall be shipped freight prepaid to the Manufacturer. The product(s) will be returned freight prepaid and allowed if it is determined by the manufacturer that the part(s) failed due to defective materials or workmanship.

This warranty does not cover consumable items, batteries, or wear items subject to periodic replacement including lamps and fuses.

Gas sensors carry a 12 months from date of shipment warranty and are subject to inspection for evidence of misuse, abuse, alteration, improper storage, or extended exposure to excessive gas concentrations. Should inspection indicate that sensors have failed due to any of the above, the warranty shall not apply.

The Manufacturer assumes no liability for consequential damages of any kind, and the buyer by acceptance of this equipment will assume all liability for the consequences of its use or misuse by the Customer, his employees, or others. A defect within the meaning of this warranty is any part of any piece of a Manufacturer's product which shall, when such part is capable of being renewed, repaired, or replaced, operate to condemn such piece of equipment.

This warranty is in lieu of all other warranties ( including without limiting the generality of the foregoing warranties of merchantability and fitness for a particular purpose), guarantees, obligations or liabilities expressed or implied by the Manufacturer or its representatives and by statute or rule of law.

This warranty is void if the Manufacturer's product(s) has been subject to misuse or abuse, or has not been operated or stored in accordance with instructions, or if the serial number has been removed.

Analytical Technology, Inc. makes no other warranty expressed or implied except as stated above.

WATER QUALITY MONITORS

Dissolved Oxygen

Free Chlorine

Combined Chlorine

Total Chlorine

Residual Chlorine Dioxide

Potassium Permanganate

Dissolved Ozone pH/ORP

Conductivity

Hydrogen Peroxide

Peracetic Acid

Dissolved Sulfide

Residual Sulfite

Fluoride

Dissolved Ammonia

Turbidity

Suspended Solids

Sludge Blanket Level

MetriNet

Distribution Monitor

GAS DETECTION PRODUCTS

NH

3

Ammonia

CO Carbon Monoxide

H

2

NO

O

2

CO

Hydrogen

Nitric Oxide

Oxygen

Cl2 Phosgene

Br

2

Cl

2

ClO

2

F

2

I

2

H

X

Bromine

Chlorine

Chlorine Dioxide

Fluorine

Iodine

Acid Gases

C

2

H

4

O Ethylene Oxide

C

2

H

6

O Alcohol

O

3

Ozone

CH

4

Methane

H

2

O

2

HCl

(Combustible Gas)

Hydrogen Peroxide

Hydrogen Chloride

HCN Hydrogen Cyanide

HF

H

2

S

NO

2

NO x

Hydrogen Fluoride

Hydrogen Sulfide

Nitrogen Dioxide

Oxides of Nitrogen

SO

2

H

2

Se

Sulfur Dioxide

Hydrogen Selenide

B

2

H

6

Diborane

GeH

4

Germane

AsH

3

PH

3

Arsine

Phosphine

SiH

4

Silane

HCHO Formaldehyde

C

2

H

4

O

3

DMA

Peracetic Acid

Dimethylamine

advertisement

Related manuals

advertisement