Dimplex DCB05C, DCB07C, DCB09C, DCB07, DCB09, DCB14 Window/Wall Box Air Conditioner Instruction Manual
Dimplex DCB05C is a window/wall box air conditioner designed for cooling purposes. With its remote control, you can easily adjust the temperature, fan speed, and mode of operation. It features a sleep timer that allows you to set the air conditioner to turn off automatically after a certain period of time, and a swing function that helps distribute the air more evenly throughout the room. The air filter is washable and reusable, making it easy to maintain. Additionally, the unit has a compact design that makes it suitable for small spaces.
विज्ञापन
विज्ञापन
Window/Wall Box
Air Conditioner
Cooling Only: DCB05C, DCB07C & DCB09C
Reverse Cycle: DCB07, DCB09 & DCB14
INSTRUCTION MANUAL
PLEASE READ THE INSTRUCTION MANUAL CAREFULLY BEFORE USING THE UNIT.
www.dimplex.com.au
Introduction
Operating Instructions
Electrical Specifications
Installation Instructions
Care and Maintenance
Trouble Shooting Guide
Table of Contents
Page
2
4
5
6
9
10
- 1 -
Introduction
Fig.1-1
Front Cover
Air inlet grille
(Indoor)
Cabinet
Air outlet grille
(Indoor)
Air inlet grille
(Outdoor)
Vent Lever
Control Panel
Air filter
DCB05C/DCB07C/DCB09C
DCB07/DCB09
SLEEP
- 2 -
DCB14
11 Compressor r unning
Operating Instructions
Remote controller
The remote controller transmits signals to the system.
No.
1
Button Function
(TEMP UP)
Increase the temperature or time by 1 unit
2 (TEMP DN) Decrease the temperature or time by 1 unit
3
4
5
ON/OFF To switch the conditioner on and off.
FAN To select the fan speed of auto/low/mid/high
TIMER To set automatic switching-on/off
FEEL
COOL
DRY
FAN
SLEEP TIMER ON TMIER OFF
AUTO
HIGH
MID
LOW
SWING
SLEEP
TIMER
MODE
FAN
SWING
ON/OFF
Remote Controller
6
8
9
SLEEP To activate the function SLEEP
MODE To select the mode of operation
SWING
To activate or deactivate of the movement of the DEFLECTORS .
The outlooking and some function of remote control may vary according to the model.
The shape and position of buttons and indicators may vary according to the model, but their function is the same.
The unit confirms the correct reception of each press button with a beep.
- 4 -
DCB05C/DCB07C/DCB09C
CAUTION
If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
RECEPTACLE AND FUSE TYPES
RATED VOLTS
AMPS
DCB05C DCB07C DCB09C
250V
7.1A
250V
7.1A
250V
7.1A
RECEPTACLE AND FUSE TYPES
RATED VOLTS
AMPS
DCB07 DCB09 DCB14
250V
7.1A
250V
7.1A
250V
8.5A
DCB07/
Installation instructions
REMOVE ALL THE SHIPPING PARTS BEFORE INSTALLATION
LOCATION
Select a location that can support the weight of the air conditioner and one that will not cause increased operation noise and vibration.
Direct sunlight is unfavorable for efficient cooling.
Select a place where there is no obstacles near the air inlet and outlet.
Less than 210
More than 55 wall thickness is less than 210
Make rear side lower so that waterwill drain out smoothy.
45
Scrape lf the wall thickness is more than 210 scrape the wall as shown above.
less than 210
more than 400
more than 500
more than 400
- 6 -
Installation instructions
CAUTION
Do not install air conditioner in the place where flammable gas leaks are a possibility.
T he minimum clearance from the appliance to combustible surfaces is 100mm
;
(Only for e lectric heating)
T he range of external static pressures at which the appliance was tested is 0-5Pa
OPERATION
Check the capacity of wiring and power outlet. The power outlet should be used exclusively for the air conditioner. Do not use it with other appliances.
Ground the air conditioner to prevent danger of electric shock.
Connect the air conditioner with power source securely.
Use a fuse as below.
CAUTION
Before installation,turn off the operation switch and disconnect the power cord.
This appliance is not intended for use by persons(including children) with reduced physical, sensory or mental capabilities,or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.
The appliance is fitted with means for disconnection from the supply mains having a contact separation in all poles that provide full disconnection under over voltage category III conditions, and these means must be incorporated in the fixed wiring in accordance with the wiring rules.
- 7 -
Installation instructions
1) Remove the front panel. (Fig.5)
Remove the air filter. (Fig.6)
Remove screw at the botton of the front panel. (Fig.7)
Open the panel cover.
2) Remove the screws fix the chassis-fixing board and cabinet.
some Models have two more screws on the back of the
3) cabinet. (Fig.8)
Grasp the handle on the front of the chassis and carefully slide the air conditioner unit out of the cabinet. (Fig.9)
4) lnstall the drain tube connection into the hole provided at the rear of the air conditioner chassis.(Fig.11)
To meet different requirement s of different type of air conditioner, there are two kinds of methods for your choice to treat the condensed water. You can choose back drainage or bottom drainage.
Bottom drainage way: the drain tray is fixed in position through four pcs of screws and use the flare nut to block
5) the back drainage hole.(Fig.15)
Back drainage way using the flare nut to block the bottom drainage hole and use water outlet pipe to connect the back drainage hole pay attention to increase the sealing ring to prevent water leakage.(Fig.16) lnstall the air conditioner cabinet on the installation shelf
(not included) with screws.(Fig.10)
6)
Carefully slide the unit back into the cabinet.(Fig .12)
7)
Reinstall the retaining bracket,front panel and mounting screws.(Fig.8,7,13)
8)
Reinstall the air filter.(Fig.14)
Fig.5
Fig.6
Fig.7
Fig.8
Screw
Fig.9
Wall
Cabinet
Installation shelf
Fig.10
Fig.14
Fig.11
Fig.12
Fig.15
drain tray screw
- 8 falre nut falre nut
Fig.13
Fig.16
sealing ring water outlet pipe
Care and Maintenance
AIR FILTER
The air filter should be washed at least once a month. lf the air filter remains full of dust, the air flow will decrease and the cooling capacity will be reduced.
The filter is behind the cover and to be pulled out from right hand side.
Wash the air filter with water an d
detergent.
Rinse with clean water and dry completely before reinstalling.
Fig.15
Fig.16
CAUTION
Let the filter dry thoroughly in the shade before reinstalling. Do not expose it directly on the sun.
Do not operate the air conditioner with the filter removed.
T1 condition: The ambient temperature for cooling: 18~43 ;
The ambient temperature for heating: -5~20 .
T3 condition : The ambient temperature for cooling: 25~52 ;
The ambient temperature for heating: -5~20 .
AIR CLEANING FILTER
The air cleaning filter is attached to the air filter.
Wash the air cleaning filter as well when wash air filter.
F R O N T C O V E R , E T C
Hot Water
The front cover will accumulate dirt and dust.
To clean it, wipe it with a soft dry cloth. When it is excessively dirty, wipe it with a soft cloth dampened with warm water or mild soap, then wipe it again thoroughly with a soft dry cloth.
Benzine,acid,etc.
- 9 -
Troubleshooting Guide
Never use hot water above 50 ,benzine,gasoline,acid,thinner or brush to wipe off dirt because they will damage the plastic surface and the coating.
LONG OFF PERIOD MAINTENANCE
Operate the fan alone ("LOW FAN"or"HIGH FAN") for half a day to dry out the inside of the unit.
Turn off power and remove plug from wall socket.
After a long off period and going to use the air conditioner again , clean the
CONDENSER(at the rear)and EVAPORATOR (at the front)fins by using a soft brush or vacuum cleaner.
CAUTION
Be careful not to damage the fins during the cleaning.
BEFORE ASKING FOR SERVICE
Check the following points before requesting for repairs or service. lf the malfunction persists,pelase contact our customer service.
Faults
Does not operate
Does not cool effectively
Cause
ls the power off?
ls the fuse blown?
ls the voltage extremely high or low?
ls the operation dial set to"off"?
ls the air filter remain full of dust or dirt?
See air filter instructions on page 9.
Is the sunlight fall directly on the unit?
ls the air flow on the rear side obstructed?
Leave a space of 500mm behind the rear side of
the air condition?
The doors or windows may be opened widely or
there are other sources of heat in the room?
The temperature dial may not set to the colder
position. Turn the dial further clockwise.
ls the ventilation damper opened?
- 10 -
CONTACT DETAILS
Glen Dimplex Australia Pty Ltd
1340 Ferntree Gully Road
Scoresby VIC 3179
Australia
Ph: 1300 556 816
Web: www.dimplex.com.au
Glen Dimplex New Zealand Ltd
38 Harris Road
East Tamaki, Auckland
New Zealand
Ph: 09 274 8265
Web: www.dimplex.co.nz
डाउनलोड