Theben SELEKTA 170 top2 24V Operating Instructions
Add to my manuals
6 Pages
THEBEN SELEKTA 170 top2 24V is an astronomical time switch designed for precise control of lighting and other electrical devices based on sunrise and sunset times. With its user-friendly interface and advanced features, it offers a range of possibilities for automating your home or business lighting.
Key capabilities of the THEBEN SELEKTA 170 top2 24V include:
-
Automatic switching based on astro times: The device calculates sunrise and sunset times based on your location and automatically adjusts the switching times accordingly.
-
Summer/winter time adjustment: It can be programmed to account for daylight saving time changes, ensuring accurate switching throughout the year.
advertisement
EN
Astro Zeitschaltuhr
SELEKTA 170 top2 24 V
1704100
307110
DuoFix ® screwless terminal
45° cable
1. Basic safety information
WARNING
Danger of death from electric shock or fire!
¾ Installation should only be carried out by a qualified electrician!
•
The device is designed for installation on DIN top hat rails (in accordance with EN 60715)
•
Power reserve (10 years) is reduced if memory card is inserted (using battery power)
•
Corresponds to type 1 BSTU nach IEC/EN 60730-2-7
!
OBELISK top2 memory card: Avoid mechanical overload and contamination during storage/transportation
Plug-in screwless terminal NC contact
Test tap
Install on DIN top hair rails (in accordance with EN 60715)
Disconnect power source
Cover or shield any adjacent live components
Ensure device cannot be switched on
Check absence of voltage
Earth and bypass
Connecting the cable
2. Proper use
•
The astronomic time switch is used, for instance, for lighting equipment (roads, external staircases, display
•
Only for use in closed, dry rooms
!
windows, entrances etc.)
Do not use on safety devices, e.g. escape route doors, fire safety equipment etc.
Disposal
Dispose of device in environmentally sound manner
3. Installation and connection
WARNING
Danger of death from electric shock or fire!
¾ Installation should only be carried out by a qualified electrician!
Time switch installation
C1
1 2 3
12-24 V
Strip cable to 8 mm (max. 9)
Insert cable in the open DuoFix ® plug-in terminal at 45° (2 cables per terminal position possible)
Only with flexible wires: To open the DuoFix nal, press screwdriver downwards
® plug-in termi-
Disconnecting the cable
Use the screwdriver to push the load line connection opener downwards
click
1
4. Device description
Display & buttons
Programmed
ON times
Date display
Channel status
ON = On
OFF = Off
0
50-60Hz
R10a -25T
6 12
2
16(4)A 250VAC 18
1
µ
24
TR 608 top2
Sunrise/sunset display
Time display
Display of active keys with relevant function
Days of the week from 1 to 7
Overview of menu selection
MENU
ASTRO u
ASTRO-
TIMES
TOTAL
SIMULATION
OFFSET
ASTRO-
MODE
LOCATION
END
PROGRAM u
NEW
CHECK
MODIFY
DELETE
TOTAL
SIMULATION
END
TIME/DATE u
TIME
SET DATE
SU-WI
WEEK DAY
FORM DATE
FORM TIME
END
¾ MENU
– Activate screen
– Open menu
– Cancel menu
– ESC
(leave menu)
Operating instructions
1. Read text lines
Flashing text/symbol
is a prompt
¾
Selection options are displayed
¾ OK
–Confirm
selection
–Confirm
selection u MANUAL u
PERM ON
PERM OFF
OVERR ON
TIMER
HOLIDAY
END
OPTIONS u
OPERATING
HOUR
LANGUAGE
PIN
FACTORY
SETTINGS
INFO
END
END
2. Make a decision
Initial start-up
Set language, country, town/city, date, time as well as summer/winter time (SO-WI)
Press any button and follow on-screen instructions (see figure)
YES
Confirmation press
OK
NO
Change/ select press t u
5. Settings and functions
ASTRO menu
In the ASTRO menu astro times, complete simulation, offset, astromode as well as position (location) can be viewed or changed.
•
Astro times
Display of the astro times (including the offsets) for the current day
•
Total simulation
Display of the switching behaviour with a freely selectable Start date (the holiday program is not displayed)
•
Offset
The offset (adjustment value) can be used to shift calculated astro times +/– 120 min. This enables the Astro switch-on and switch-off times to be adapted to local circumstances (e.g. mountains, high buildings etc.) or to personal requirements.
2
•
Astro mode
–
–
–
Evenings on, mornings off Switches on at sunset, switches off at sunset (Example: street lighting)
Evenings off, mornings on Switches off at sunset, switches on at sunrise (Example: terrarium).
Astro inactive The astro times are ineffective (timer function only).
•
Position
– Location set by selecting a city or by coordinates
(latitude/longitude, time zone). The OBELISK top2 memory card allows up to 10 further cities (= favourites) to be entered.
Change astro time/position
Setting the offset function
MENU
ASTRO u
ASTRO TIMES
TOTAL
SIMULAION
OFFSET
ASTROMODE u
OFFSET
MORNING
OFFSET
MORNING
00:00 u OFFSET
EVENING
OFFSET
EVENING
00:00
MENU
ASTRO u
ASTRO TIMES
TOTAL
SIMULATION
OFFSET
ASTROMODE
LOCATION
END u
COUNTRY
COORDINATES u
Press MENU
Select ASTRO and press OK to confirm
Select OFFSET and press OK to confirm
Select OFFSET MORNING or OFFSET EVENING and press OK ¾
to confirm
Set the time and press OK to confirm
Set fixed switching time
MENU
PROGRAM u u
FRANCE u
ESPANA
ESTONIA
DEUTSCHLAND
GREAT BRITAIN
AJACCIO
BAYONNE
BORDEAUX
BREST
CAEN
NEW
CHECK u
MODIFY
DELETE
TOTAL-
SIMULATION
END
MEM FREE 56
NIGHT BREAK or
HOUR
MINUTE
MONDAY
DURATION
UNTIL
LIGHT ON
Start
Copy switching to other days of the week.
The day of the week always relates to a start time
SAVE
COPY
ADD TUESDAY
SAVE
Switching time for one day
E.g. enter a different country, a different town/city
Press MENU (see picture).
L A switching time always consists of a start time and an end time (LASTS UNTIL). e.g. night switch-off on Monday
23:00 – 05:00 hrs
L There are 56 memory cells available
Press MENU
Select PROGRAM and press OK to confirm
Select NEW and press OK to confirm
Select NIGHT SWITCH OFF or DAY SWITCH ON and press OK
to confirm
Set selected switching times (hours, minutes, day) and
press OK to confirm
Select COPY or SAVE
To save press
¾ u
To copy press OK
and press OK to confirm
3
Setting summer/winter time
MENU
TIME/DATE u
TIME
DATE
OFFSET
SU-WI
WEEK DAY u
SU-WI EUROPA
SU-WI EUROPE
WEST
SU-WI EUROPE
EAST
Setting holiday function
MENU
MANUAL u
PERM ON
PERM OFF
OVERR ON
TIMER
HOLIDAY u ON
BEGIN HOLIDAY
END HOLIDAY
Press MENU
Select TIME/DAT and press OK to confirm
Select SO-WI and press OK to confirm
Select region for the SO-WI time and press OK to confirm
Switch Permanent ON / OFF
MENU
MANUAL u
PERM ON
PERM OFF
OVERR ON
TIMER
HOLIDAY
END
Press MENU
Select MANUAL and press OK to confirm
Select PERMANENT ON or PERMANENT OFF and press OK to confirm
Press MENU
Select MANUAL and press OK to confirm
Select HOLIDAY and press OK to confirm
Select ON and press OK to confirm
Select START HOLIDAY and press OK to confirm
Enter YEAR, MONTH, DAY, HOUR and press OK to confirm
Select END HOLIDAY and press OK to confirm
Enter YEAR, MONTH, DAY, HOUR and press OK to confirm
Activate PIN-Code
The PIN code is set in OPTIONS via the menu.
L If you have lost the PIN, please call the Theben Hotline.
L Have the serial number ready!
MENU
OPTIONS
OPERATING
HOUR
EXT INPUT u
LANGAGE
PIN
FACTORY
SETTINGS
INFO u NO PIN
WITH PIN u CURRENT PIN
NEW PIN
00:00 u
Setting manual or permanent switching
Manual and permanent switching can be set using the menu in MANUAL or (in the automatic screen) by key combination
(see fig).
•
Manual control
Reversing the channel status to the next automatic or programmed switching.
•
Permanent switching
As long as a permanent switching (on or off) is activated, the programmed switching times are ineffective.
4
ok
Activate manual switching
Briefly press both keys simultaneously
Activate permanent switching
Simultaneously press both keys for 2 seconds
Cancelling manual/permanent switching
Press both keys simultaneously
Operating hour counter
The operating hours of the channel (relay) are displayed and deleted in the OPTIONS menu. If the number of operating hours exceeds the value set in the Service menu, SERVICE will appear in the display.
Example: Replace a lamp after 5,000 h.
Delete operating hours or set a higher value in Service (e.g. to 10,000 h)
Using the OBELISK top2 memory card
L The OBELISK top2 memory card is not included in the scope of supply of the device, but can be ordered as an accessory (no. 9070404).
All functions can also be set on the PC using the OBELISK software and transferred to the device via the memory card.
Insert memory card in the time switch
Read in/out saved switching times and device setups in the time switch or start Obelisk program
Remove OBELISK top2 memory card after copying etc.
!
Avoid mechanical overload and contamination during storage/transport
Copy OBELISK → Time switch
Copies all switching programs and settings from the time switch to the memory card. Starting OBELISK program
Copy Time switch →OBELISK
Copies all switching programs and settings from the time switch to the memory card.
Start OBELISK program
Takes on the switching times that are programmed on the memory card.
As soon as the memory card is removed, the switching times of the time switch are re-activated.
OBELISK
COPY
OBELISK -> TIME
SWITCH u
TRANSCRIBE OK
COPY TIME
SWITCH ->
OBELISK
OVERWRITE OK u
RUN OBELISK u
CHECK OBELISK
Resetting the time switch
Press the 4 buttons simultaneously.
▻ You can choose between RETAIN PROGRAM and DELETE
PROGRAM.
6. Technical Data
Operating voltage:
Power consumption: max
Standby
Max switching capacity.
Switching capacity
Min. switching capacity
Shortest switching time
Protection rating
Protection class
Protection class
12–24 V, 50–60 Hz, +10 % /
–15 %,
12–24 V DC, +10 % / –15 %
0,6 W
0,2 W
16 A (at 250 V AC, cos ϕ
= 1)
2 A (at 250 V AC, cos ϕ = 0,6)
10 mA/230 V AC
100 mA/24 V AC/DC
1 min
IP 20 in accordance with EN
60529
Protection class: II in accordance with EN 60730-1 subject to designated installation for supply with FELV and/or mains switching
III for supply with SELV and switching of SELV
Operating temperature
Power reserve
Time accuracy
Rated impulse voltage
Pollution degree
Contact
–30 °C … +55 °C
10 years at +20 °C
± 0,25 s/day (25 °C)
4 kV
2 two way switch, contact µ
50 000 Max. switching cycles with 16 A resistive load
Incandescent lamp load (230 V)
Halogen lamp load (230 V)
1000 W
1000 W
Fluorescent lamps (LLB low-loss ballasts): uncorrected (230 V) series-corrected (230 V) parallel-corrected (230 V)
Fluorescent lamps (EB – electronic ballasts) (230 V)
1000 VA
1000 VA
80 W (12 µF)
120 W
Compact fluorescent lamps (EB) (230 V) 30 W
Corresponds to type 1 BSTU in accordance with IEC/EN 60730-2-7 or
IEC/EN 60730-1
5
Switching of any external conductor is permitted
Approved for switching SELV and mains voltage
7. Contact
Theben AG
Hohenbergstr. 32
72401 Haigerloch
GERMANY
Tel. +49 7474 692-0
Fax +49 7474 692-150
Hotline
Tel. +49 7474 692-369 [email protected]
Addresses, telephone numbers etc. www.theben.de
6
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement