Kemppi FastMig KMS 400 MVU Owner's Manual
Kemppi FastMig KMS 400 MVU is multi-operator power source designed for demanding professional use. It is suitable for MMA and MIG welding in DC.
The device is equipped with a control panel that allows for precise adjustment of welding parameters, including wire feed speed, voltage, and inductance. It also features a digital display that provides real-time feedback on the welding process.
The FastMig KMS 400 MVU is a versatile machine that can be used for a wide range of welding applications, including:
- General fabrication
- Automotive repair
- Shipbuilding
- Construction
The device is also equipped with a number of safety features, including thermal overload protection, over/under voltage protection, and a built-in cooling fan. These features help to ensure the safety of the operator and the machine.
Anúncio
Anúncio
FastMig
KMS 400 MVU
Operating manual
Brugsanvisning
EN
NO
Operating manual english
EN
EN
COntents
1. Preface
......................................................................................................................................
3
1.1 General
.......................................................................................................................................
3
1.2 Product introduction
............................................................................................................
4
1.2.1 Operation control and connectors .................................................................................
4
1.3 Accessories
................................................................................................................................
5
1.3.1 Remote control devices ...................................................................................................
1.3.2 Cables ...............................................................................................................................
5
5
2. Installation
.............................................................................................................................
6
2.1 Positioning of the machine
................................................................................................
6
2.2 Distribution network
.............................................................................................................
6
2.3 Connection to the mains supply
......................................................................................
6
2.4 Welding and earth cables
....................................................................................................
7
3. Operation control switches and potentiometers
.......................................
7
3.1 Main switch I/O
.......................................................................................................................
7
3.2 Pilot lamps
.................................................................................................................................
7
3.3 Operation of cooling fan
.....................................................................................................
7
4. Manual metal arc welding
..........................................................................................
8
5. Maintenance
........................................................................................................................
8
5.1 Cables
..........................................................................................................................................
8
5.2 Power source
............................................................................................................................
8
5.3 Regular maintenance
............................................................................................................
8
6. Operation disturbances
...............................................................................................
9
6.1 Operation of the overload protection
............................................................................
9
6.2 Control fuses
............................................................................................................................
9
6.3 Under- and overvoltages in the mains supply
............................................................
9
6.4 Loss of a phase in the mains supply
................................................................................
9
7. Disposal of the machine
..............................................................................................
9
8. Ordering numbers
.........................................................................................................
10
9. Technical data
...................................................................................................................
11
2
FastMig KMS 400 MVU
1. prefaCe
1.1 general
Congratulations on choosing the FastMig welding equipment. Used correctly, Kemppi products can significantly increase the productivity of your welding, and provide years of economical service.
This operating manual contains important information on the use, maintenance and safety of your Kemppi product. The technical specifications of the equipment can be found at the end of the manual.
Please read the manual carefully before using the equipment for the first time. For your own safety and that of your working environment, pay particular attention to the safety instructions in the manual.
For more information on Kemppi products, contact Kemppi Oy, consult an authorised Kemppi dealer, or visit the Kemppi web site at www.kemppi.com.
The specifications presented in this manual are subject to change without prior notice.
important notes
Items in the manual that require particular attention in order to minimise damage and personal harm are indicated with the ’NOTE!’ notation. Read these sections carefully and follow their instructions.
Disclaimer
While every effort has been made to ensure that the information contained in this guide is accurate and complete, no liability can be accepted for any errors or omissions. Kemppi reserves the right to change the specification of the product described at any time without prior notice. Do not copy, record, reproduce or transmit the contents of this guide without prior permission from Kemppi.
EN
© Kemppi Oy / 1339
3
1.2 product introduction
FastMig KMS 400 MVU is multi-operator power source designed for demanding professional use. It is suitable for MMA and MIG welding in DC.
1.2.1 Operation control and connectors
EN
H11
S11
H12
X14
X12
X11 X13
6,3A
F11
H11
H12
Fuse for connection for control table
Signal lamp
Warning lamp for thermal protection
6,3 A delayed
I/O
S11 Main switch I/O
X11, X13 Welding connection parallel
X12 Earth connection
X14 , X15 Connection for control cable
01 Inlet of mains cable
01
F11
X15 parallel
4
FastMig KMS 400 MVU
1.3 accessories
1.3.1 remote control devices
R10
R20
1.
1. Control of MMA/TIG welding current, reference scale 1 … 5.
1.
2.
1. Wire feed adjustment, electrode current adjustment.
2. Voltage adjustment.
MIG-MAG remote control device with controls for wire feed and voltage, memory scales 1 … 5.
You can use control device also for control of MMA current.
1.3.2 Cables fastmig Kms 400 mVu
EN
16d
20
21
R10, R20
Extension cable for remote control
Earth cable
MMA welding cable
Remote control devices
© Kemppi Oy / 1339
5
EN
2. installatiOn
2.1 positioning of the machine
Place the machine on a firm, dry and level surface. Where possible, do not allow dust or other impurities to enter the machines cooling air flow. Preferably site the machine above floor level; for example on a suitable carriage unit.
Notes for positioning the machine
• The surface inclination should not exceed 15 degrees.
• Ensure the free circulation of the cooling air. There must be at least 20 cm of free space in front of and behind the machine for cooling air to circulate.
• Protect the machine against heavy rain and direct sunshine.
Note! the machine should not be operated in the rain as the protection class of the machine, IP23S, allows for outside preserving and storage only.
NOTE! Never aim metallic grinding spray/sparks towards the equipment.
2.2 Distribution network
All regular electrical devices without special circuits generate harmonic currents into distribution network. High rates of harmonic current may cause losses and disturbance to some equipment.
This equipment complies with IEC 61000-3-12 provided that the short-circuit power Ssc is greater than or equal to 4.7 MVA at the interface point between the user’s supply and the public supply network. It is the responsibility of the installer or user of the equipment to ensure, by consultation with the distribution network operator if necessary, that the equipment is connected only to a supply with a short-circuit power Ssc greater than or equal to 4.7 MVA.
2.3 Connection to the mains supply
FastMig power sources are delivered equipped with 5 m mains cable without plug.
If local electricity regulations of operating country are stating otherwise, the mains cable should be replaced in conformity with the local regulations.
Connection of the mains cable, mounting and change of the plug should only be carried out by a competent electrician.
Remove the machine’s right side plate to enable the mounting of a mains cable.
KMS 400 MVU power source can be connected to the mains supply of 230 V 3~ or 400 V 3~ .
if changing the mains cable take into consideration the following:
The cable is entered into the machine through the inlet ring on the rear panel of the machine and fastened with a cable clamp (05). The phase conductors of the cable are coupled to connectors L1, L2 and L3. The earth protection coloured green-yellow is coupled to connector.
Note! If you are using 5-lead cable, do not connect neutral conductor.
6
FastMig KMS 400 MVU
Sizes of the mains cables and fuse ratings for the machine at 100 % duty cycle are specified in the table below:
Rated voltage Fuses, slow-blow Connection cable *) mm²
400 V 3~ 35 A H07RN-F 4G10 (10 mm²)
230 V 3~ 50 A H07RN-F 4G10 (10 mm²)
*) In cables of S type there is a protective grounding conductor coloured green-yellow.
2.4 Welding and earth cables
Recommended copper cables with cross-sectional area are as follows:
FastMig KMS 400 MVU 70 ... 90 mm²
In enclosed table are shown typical load capacities of rubber insulated copper cables, when ambient temperature is 25º C and lead temperature is 85º C.
Cable
50 mm²
70 mm²
95 mm²
Duty cycle ED
100 %
285 A
355 A
430 A
60 %
370 A
460 A
560 A
30 %
520 A
650 A
790 A
Voltage loss / 10 m
0,35 V / 100 A
0,25 V / 100 A
0,18 V / 100 A
Do not overload welding cables due to voltage losses and heating.
Fasten the earth clamp of the return current cable carefully, preferably direct onto the piece to be welded. The contact surface of the earth clamp should always be as large as possible.
Clean the fastening surface from paint and rust.
EN
3. OperatiOn COntrOl sWitChes anD pOtentiOmeters
3.1 main switch i/O
When you turn the switch into I-position, pilot lamp H11 on the front face is illuminated and the machine is ready for use.
NOTE! switch.
Always turn the machine on and off with the mains switch, never use the mains plugs as a
3.2 pilot lamps
The pilot lamps of the machine report the electric operation:
The green pilot lamp H11 when lit indicates that the machine is on and ready for use and it is connected to the mains supply with the main switch in the I-position.
H12 indicates when lit that the thermal protection of the machine has been activated due to over heating. The cooling fan will continue to run and cool the machine down and when the lamp is off the machine is ready to weld.
3.3 Operation of cooling fan
In FastMig power sources there are two simultaneously operating fans.
• The fan is started for a moment when main switch is placed into position I.
• The fan will start during welding as the machine heats up and it will run for 1 to 10 minutes after the welding has stopped.
© Kemppi Oy / 1339
7
4. manual metal arC WelDing
The FastMig power source can be used in electrode welding by connecting a FastMig
MFS 53, MFS 55 or MSF 57 wire feeder to it. The power source can be made suitable for electrode welding without a wire feeder by connecting an R10 or R20 remote control to the
X14 or X15 terminal at the back of the power source for welding current adjustment, and the welding power cable connected to the power source’s (+) connector X11 or X12.
EN
5. maintenanCe
The amount of use and the working environment should be taken into consideration when planning the frequency of maintenance of the machine. Careful use and preventive maintenance will help to ensure trouble-free operation.
5.1 Cables
Check the condition of welding and connection cables daily. Do not use damaged cables.
Make sure that the mains cables in use are safe and according to laid down regulations.
The repair and mounting of a mains connection cable should be carried out only by an authorised electrician.
5.2 power source
NOTE! Disconnect the plug of the machine from the mains socket and wait approx. 2 minutes
(capacitor charge) before removing the cover plate.
Check at least every half year:
• Electric connectors of the machine – clean the oxidised parts and tighten the loosened ones.
• Note! You must know correction tension torques before starting the reparation of the joints.
• Clean the inner parts of the machine from dust and dirt e.g. with a soft brush and vacuum cleaner. Also clean the ventilation net behind the front grate.
• Do not use compressed air, there is a risk that dirt is packed even more tightly into gaps of cooling profiles.
• Do not use pressure washing device.
• Only authorised electrician shall carry out repairs to the machines.
5.3 regular maintenance
Kemppi Service Workshops make regular maintenance according to agreement.
the major points in the maintenance procedure are listed as follows:
• Cleaning of the machine
• Checking and maintenance of the welding tools
• Checking of connectors, switches and potentiometers
• Checking of electric connections
• Checking of mains cable and plug
• Damaged parts or parts in bad connection are replaced by new ones
• Maintenance testing. Operation and performance values of the machine are checked, and adjusted when necessary by means of test equipment.
8
FastMig KMS 400 MVU
6. OperatiOn DisturbanCes
In the event of a failure of the machine, contact an authorised Kemppi service agent or your local Kemppi dealer.
Check the maintenance objects before the machine is sent to the Service Workshop.
6.1 Operation of the overload protection
Yellow pilot lamp H12 of thermal protection is lit when thermostat has operated due to overheating of machine.
The thermostat of machine will operate, if machine is continuously loaded over rated values or cooling air circulation is blocked.
Cooling fan cools down the machine and when the pilot lamp is not lit the machine is automatically ready for welding.
6.2 Control fuses
Fuse F11, 6,3 A delayed, on the rear wall of machine is as protection for connection of auxiliary devices X14-15.
NOTE! Use same type and rating of fuse which is marked beside the fuse adapter. Damage caused by a wrong type fuse is not covered by the guarantee.
6.3 under- and overvoltages in the mains supply
Primary circuits of machine are protected against sudden, transient overvoltages.
Machine is designed to withstand 3 x 440 V voltage continuously (see technical data). See to it that voltage is kept within admissible limits especially when mains supply is taken e.g. from combustion engine generator.
If the mains has undervoltage (under approx. 300 V) or overvoltage (over approx. 480 V) machine control stops to operate automatically.
6.4 loss of a phase in the mains supply
Loss of a phase causes noticeable poorer welding properties than normally or the machine doesn’t get started at all. Loss of a phase can be due to following:
• blowing of mains supply fuse
• defective mains cable
• bad connection of mains connection cable on terminal block or plug of machine
EN
7. DispOsal Of the maChine
Do not dispose of electrical equipment with normal waste!
In observance of European Directive 2002/96/EC on waste electrical and electronic equipment, and its implementation in accordance with national law, electrical equipment that has reached the end of its life must be collected separately and taken to an appropriate environmentally responsible recycling facility.
The owner of the equipment is obliged to deliver a decommissioned unit to a regional collection centre, per the instructions of local authorities or a Kemppi representative. By applying this European Directive you will improve the environment and human health.
© Kemppi Oy / 1339
9
EN
8. OrDering numbers
FastMig KMS 400 MVU
Wire feeders
MXF 65
MXF 67
MXF 63
MXF 65
MXF 67
MXF 63
MSF 53
MSF 55
MSF 57
Panels for wire feeders
SF 51
SF 52W
SF 53W
SF 54
Accessories
Return current cable
Return current cable
Cable for MMA welding
Cable for MMA welding
R10
Remote controlled interconnecting cable
Cooling unit FastCool 10
Transport unit PM 500
Gun holder GH 30
5 m, 50 mm²
5 m, 70 mm²
5 m, 50 mm²
5 m, 70 mm²
10 m
605400003
6152100EL
6152200EL
6152300EL
6152100
6152200
6152300
6065300
6065500
6065700
6085100
6085200W
6085300W
6085400
6184511
6184711
6184501
6184701
6185409
6185481
6068100
6185291
6256030
10
FastMig KMS 400 MVU
9. teChniCal Data
FastMig™ KMS 400 MVU
Connection voltage
Rated power
Primary current
Connection cable
Fuse (delayed)
Duty cycle 40 °C
Welding range
Max. welding voltage
Open circuit voltage
Idle power
Efficiency at max. current
Power factor at max. current
Operating temperature range
Storage temperature range
Degree of protection
EMC class
Minimun short circuit power Ssc of supply network*
External dimensions
Weight
Operating voltage
(for cooling unit)
* See paragraph 3.2.
3~, 50/60 Hz
MIG, 80%ED I
1max
MIG, 100%ED I
1
MMA, 80%ED I
1max
MMA, 100%ED I
1
H07RN-F
80 % ED
100 % ED
MIG
MIG
MMA
400 V
400 V -15 %...+20 %
19 kVA
46 V
55 ... 69 V
50 V
25 W
87 %
0.8
-20 ... +40 ºC
-40 ... +60 ºC
IP23S
A
4.7 MVA
27A
26A
29A
27A
4G6 (5 m)
35 A
400 A/36 V
380 A/35 V
10 V ... 39 V length width height
590 mm
230 mm
580 mm
49 kg
400 V -15 %...+20 %
230 V
230 V -10 %...+10 %
20 kVA
46 V
55 ... 69 V
50 V
25 W
87 %
0.8
-20 ... +40 ºC
-40 ... +60 ºC
IP23S
A
4.7 MVA
48A
45A
50A
47A
4G6 (5 m)
35 A
400 A/36 V
380 A/35 V
10 V ... 39 V
590 mm
230 mm
580 mm
49 kg
400 V -15 %...+20 %
EN
© Kemppi Oy / 1339
11
KEMPPI OY
Kempinkatu 1
PL 13
FI-15801 LAHTI
FINLAND
Tel +358 3 899 11
Telefax +358 3 899 428 [email protected]
www.kemppi.com
Kotimaan myynti:
Tel +358 3 899 11
Telefax +358 3 734 8398 [email protected]
KEMPPI SVERIGE AB
Box 717
S-194 27 UPPLANDS VÄSBY
SVERIGE
Tel +46 8 590 783 00
Telefax +46 8 590 823 94 [email protected]
KEMPPI NORGE A/S
Postboks 2151, Postterminalen
N-3103 TØNSBERG
NORGE
Tel +47 33 346000
Telefax +47 33 346010 [email protected]
KEMPPI DANMARK A/S
Literbuen 11
DK-2740 SKOVLUNDE
DANMARK
Tel +45 4494 1677
Telefax +45 4494 1536 [email protected]
KEMPPI BENELUX B.V.
Postbus 5603
NL-4801 EA BREDA
NEDERLAND
Tel +31 765717750
Telefax +31 765716345 [email protected]
KEMPPI (UK) Ltd
Martti Kemppi Building
Fraser Road
Priory Business Park
BEDFORD, MK44 3WH
UNITED KINGDOM
Tel +44 (0)845 6444201
Telefax +44 (0)845 6444202 [email protected]
KEMPPI FRANCE S.A.S.
65 Avenue de la Couronne des Prés
78681 EPONE CEDEX
FRANCE
Tel +33 1 30 90 04 40
Telefax +33 1 30 90 04 45 [email protected]
KEMPPI GmbH
Perchstetten 10
D-35428 LANGGÖNS
DEUTSCHLAND
Tel +49 6 403 7792 0
Telefax +49 6 403 779 79 74 [email protected]
KEMPPI SPÓŁKA Z O.O.
Ul. Borzymowska 32
03-565 WARSZAWA
POLAND
Tel +48 22 7816162
Telefax +48 22 7816505 [email protected]
KEMPPI AUSTRALIA PTY LTD.
13 Cullen Place
P.O. Box 5256, Greystanes NSW 2145
SMITHFIELD NSW 2164
AUSTRALIA
Tel. +61 2 9605 9500
Telefax +61 2 9605 5999 [email protected]
OOO KEMPPI
Polkovaya str. 1, Building 6
127018 MOSCOW
RUSSIA
Tel +7 495 739 4304
Telefax +7 495 739 4305 [email protected]
ООО КЕМППИ ул. Полковая 1, строение 6
127018 Москва
Tel +7 495 739 4304
Telefax +7 495 739 4305 [email protected]
KEMPPI, TRADING (BEIJING) COMPANY,
LIMITED
Room 420, 3 Zone, Building B,
No.12 Hongda North Street,
Beijing Economic Development Zone,
100176 Beijing
CHINA
Tel +86-10-6787 6064
+86-10-6787 1282
Telefax +86-10-6787 5259 [email protected]
肯倍贸易(北京)有限公司
中国北京经济技术开发区宏达
北路 12 号
创新大厦 B 座三区 420 室 ( 100176 )
电话: +86-10-6787 6064
+86-10-6787 1282
传真: +86-10-6787 5259 [email protected]
KEMPPI INDIA PVT LTD
LAKSHMI TOWERS
New No. 2/770,
First Main Road,
Kazura Garden,
Neelankarai,
CHENNAI - 600 041
TAMIL NADU
Tel +91-44-4567 1200
Telefax +91-44-4567 1234 [email protected]
www.kemppi.com
Download
Anúncio