Cadel GLOBE, VEGA, cloe Installation, Use And Maintenance Manual
Advertisement
Advertisement
en
PELLET STOVE
installation
, use and maintenance manual
VEGA - SIRE 3 PLUS - DOGE 3 PLUS - SFERA 3 - SFERA 3 PLUS
PRINCE 3 - PRINCE 3 PLUS - ELISE 3 PLUS - GLOBE - TREND
©2015 CADEL srl | All rights reserved – tutti i diritti riservati
EN
Summary
1 MANUAL SIMBOLOGY .........................................3
2 DEAR CUSTOMER ................................................. 3
3 CAUTIONS ............................................................3
4 SAFETY REQUIREMENTS ........................................4
5 WARRANTY CONDITIONS ....................................5
6 SPARE PARTS .........................................................6
7 WARNINGS FOR THE CORRECT DISPOSAL OF THE
PRODUCT .....................................................................6
8 PACKAGING AND HANDLING ............................6
8.1 PACKAGING ....................................................6
8.2 STOVE HANDLING ............................................6
9 CHIMNEY FLUE ..................................................... 6
9.1 INTRODUCTION ................................................6
9.2 CHIMNEY FLUE ..................................................7
9.3 TECHNICAL FEATURES ......................................7
9.4 HEIGHT-DEPRESSION ........................................8
9.5 MAINTENANCE .................................................8
9.6 CHIMNEY POT ...................................................8
9.7 CHIMNEY COMPONENTS ................................9
9.8 EXTERNAL AIR INLET ........................................10
9.9 COMBUSTIBLE AIR INLET FOR SEALED-CHAMBER
INSTALLATION .........................................................10
9.10 CHIMNEY FLUE CONNECTION .....................11
9.11 EXAMPLES OF CORRECT INSTALLATION ......12
10 FUEL .....................................................................13
10.1 FUEL ................................................................13
11 INSTALLATION .................................................... 14
11.1 INTRODUCTION .............................................14
11.2 OVERALL DIMENSIONS .................................14
11.3 GENERAL INSTALLATION ...............................20
11.4 FRONTAL PANEL ASSEMBLY (VEGA / TREND /
PRINCE 3 / PRINCE 3 PLUS MODELS) .......................20
11.5 TILE ASSEMBLY (SIRE 3 PLUS MODEL) .............20
11.6 PANELS ASSEMBLY (SFERA 3 / SFERA 3 PLUS
MODELS) ................................................................21
11.7 FRONTAL PANEL ASSEMBLY (VEGA STONE
MODEL) ..................................................................22
11.8 ELECTRIC CONNECTION ..............................22
11.9 CONNECTION TO THE EXTERNAL THERMOSTAT....23
11.10 VENTILATION ................................................23
11.11 HOT AIR DUCTING SYSTEM (VEGA / TREND /
SIRE 3 PLUS / DOGE 3 PLUS / SFERA 3 PLUS / ELISE 3 PLUS
/ PRINCE 3 PLUS MODELS) ......................................23
11.12 USING THE STOVE WITHOUT DUCTING .......25
12 USE .....................................................................25
12.1 INTRODUCTION .............................................25
12.2 CONTROL PANEL ..........................................26
12.3 USER MENU ....................................................27
12.4 START UP ........................................................27
12.5 STOVE ADJUSTMENT .....................................27
12.6 FAILED IGNITION............................................28
12.7 POWER FAILURE ............................................28
2
12.8 TEMPERATURE SETTING .................................28
12.9 FUME TEMPERATURE ......................................28
12.10 SWITCHING OFF ...........................................28
12.11 CLOCK SETTING ...........................................28
12.12 DAILY PROGRAMMING ..............................28
12.13 WEEKEND PROGRAMMING ........................28
12.14 WEEKLY PROGRAMMING ...........................29
12.15 FAN ADJUSTMENT ........................................29
12.16 PELLET SUPPLY ..............................................29
12.17 REMOTE CONTROL .....................................30
13 SAFETY SYSTEM ...................................................30
13.1 INTRODUCTION .............................................30
13.2 "BLACK OUT" ALARM ....................................30
13.3 "EXHAUST PROBE" ALARM ............................30
13.4 "HOT EXHAUST" ALARM .................................30
13.5 "FAN FAILURE" ALARM ..................................31
13.6 "FAILED IGNITION" ALARM ............................31
13.7 "NO PELLET" ALARM ......................................31
13.8 "THERMAL SAFETY" ALARM ...........................31
13.9 "FAILURE DEPRESS" ALARM ...........................31
13.10 "DOOR OPEN" ALARM ................................31
14 MAINTEINANCE .................................................. 31
14.1 INTRODUCTION .............................................31
14.2 BURNING POT AND ASH TRAY CLEANING ....32
14.3 HOPPER AND AUGER CLEANING ................33
FUME CHAMBER AND FUME PASSAGES
CLEANING ..............................................................33
14.5 FUME CONDUIT CLEANING ..........................35
14.6 FUME FAN CLEANING ...................................36
14.7 ROOM FAN CLEANING ................................36
14.8 FUME PIPES ANNUAL CLEANING .................37
14.9 GENERAL CLEANING ....................................37
14.10 CLEANING OF PAINTED METAL PANELS ....37
14.11 CLEANING OF CERAMIC AND STONE PANELS ... 37
14.12 GASKET REPLACEMENT ...............................37
14.13 GLASS CLEANING ........................................37
15 IN CASE OF ANOMALY ......................................38
15.1 ALARMS .........................................................38
15.2 PROBLEM SOLVING ......................................40
16 TECHNICAL DATAS .............................................43
16.1 REPAIR INFORMATION ..................................43
16.2 FEATURES .......................................................44
VEGA - SIRE 3 PLUS - DOGE 3 PLUS - SFERA 3 - SFERA 3 PLUS - PRINCE 3 - PRINCE 3 PLUS - GLOBE - TREND - ELISE 3 PLUS
EN
1
MANUAL SIMBOLOGY
• The icons with the stylized figures indicates whom the subject dealt in the paragraph is addressed to (between the User and/or the Authorized Technician and/or the Specialized Stove-repairer).
• WARNING symbols indicates an important note.
USER
AUTHORISED TECHNICIAN
(ONLY to interpret or the Stove-manufacturer or the Authorized
Technician of Technical Assistance Service approved by the Stovemanufacturer)
SPECIALIZED STOVE-REPAIRER
CAUTION:
READ CAREFULLY THE NOTE
CAUTION:
DANGER OR IRREVERSIBLE DAMAGE POSSIBILITY
2
DEAR CUSTOMER
• Our products are designed and manufactured in compliance with standards EN 13240 for wood stoves,
EN 14785 for pellet stoves, EN 13229 for fire places, EN 12815 for wood cooker stoves, C.P.R. 305/2011 for manufacturing products, Re n.1935/2004 for materials and objects which are in contact with foods, Dir.
2006/95/CEE for low tension, Dir.2004/108/EC for Electromagnetic compatibility.
• Read carefully the instruction contained in this manual to obtain the best efficiency.
• This instruction manual is an integral part of the product: make sure it is delivered with the appliance also in case of sold to others. In case of loss please ask a copy to your local Technical Assistance Service.
In Italy biomass system installation below 35 kW must comply with MD 37/08. Every qualified installer who own these requirements, has to issue the certificate of conformity for the installed system ("system" means: stove + chimney + air inlet).
• According to (EU) No. 305/2011 regulation, the " Declaration of Performance" is available online at the web sites:
- www.cadelsrl.com
- www.free-point.it
3
CAUTIONS
• All the pictures carried in this manual are only for indicative and explanatory purpose and could therefore slightly differ from your appliance.
• The referring appliance is those you purchased.
• In case of doubts or difficulties in the comprehension or for problems not described in this manual, please promptly contact your distributor or installer.
VEGA - SIRE 3 PLUS - DOGE 3 PLUS - SFERA 3 - SFERA 3 PLUS - PRINCE 3 - PRINCE 3 PLUS - GLOBE - TREND - ELISE 3 PLUS 3
EN
4
SAFETY REQUIREMENTS
• Installation, electrical connection, functional verification and maintenance must
• Live electrical parts: disconnect the product from the 230V power supply before performing any maintenance operation. Only power the product after completing
•
•
•
Special maintenance must only be performed by authorised and qualified
All local regulations, including those referring to national European standards, must
The manufacturer declines any responsibility in case of installation which are not
•
•
It is forbidden to install the stove in bedrooms, bathrooms and in rooms used for storing combustible materials and in one-room flats.
• If there are highly flammable objects (curtains, fitted carpet, etc...), all these
• The electrical cable must not get in touch with the fume exhaust pipe and nor with
• The user, or whoever is operating the product, must read and fully understand the contents of this installation and use guide before performing any operation. Errors or
•
•
The type of fuel to use is only the pellets.
Do not use the appliance as waste inceneretor.
• It is forbidden to operate the product with the door open or the glass broken.
• Do not use flammable liquids during the ignition (alcool, petrol, oil, etc...).
• After a failed ignition the burning pot must be empty from the amassed pellets,
• The pellet hopper must always be closed with its own lid.
• Before of every intervention leave the fire completely extinguish till the cooling and always disconnect the plug from the electric socket.
• This appliance can be used by children aged from 8 years and above and persons knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play without supervision.
• Packaging are not toys and could cause suffocation or strangulation and other deseases or without experience and knowledge must be kept away from packaging.
The stove is not a toy.
4 VEGA - SIRE 3 PLUS - DOGE 3 PLUS - SFERA 3 - SFERA 3 PLUS - PRINCE 3 - PRINCE 3 PLUS - GLOBE - TREND - ELISE 3 PLUS
EN
• During its running, the stove reaches high temperatures: keep away childreen and
• The hand rejector can be removed exclusively by an authorized technician.
• The chimney flue must be cleaned, since the soot and unburnt oil deposits reduce
• If the pellets are of bad quality (if contains sizing agents, oils, varnishes, plastic remains or if it is mealy), deposits will form along pellets drop pipe during the running. along the pipe could reach the pellets on the hopper burning them and creating a thick and harmful smoke inside the room. Please always keep the hopper closed with
• In case it would be necessary to extinguish the fire emitted by the stove or by the extinguish the fire inside the burning pot.
5
WARRANTY CONDITIONS
The company guarantees the product, with the exception of elements subject to normal wear listed below, for a period of 2 (two) years from the date of purchase attested by:
• a document to serve as proof of purchase (invoice and/or receipt) that shows the name of the vendor and the date on which the purchase was made;
• forwarding of the completed certificate of guarantee within 8 days of purchase.
Furthermore, the product must be installed and started by specialised personnel who must, where provided, issue a declaration of conformity of the plant and of the proper functioning of the product, for the warranty to be valid and effective.
We recommend testing the product before completion with the relative finishes (claddings, painting of walls, etc.).
Installations not meeting the current standards, improper use and lack of maintenance as expected by the manufacturer, void the product warranty.
The guarantee is valid on the condition that the instructions and warnings contained in the use and maintenance manual are observed, and therefore the product is used correctly.
The replacement of the entire system or the repair of one of its components does not extend the guarantee period, and the original expiry date remains unchanged.
The guarantee covers the replacement or free repair of parts recognised as being faulty at source due to manufacturing defects .
To benefit from the guarantee, in the event of a fault, the customer must have the guarantee certificate and present it with the proof of purchase document to the Technical Assistance Office.
The guarantee does not cover malfunctions and/or damage to the appliance that arise due to the following causes:
• Damage caused during transportation or relocation.
• All parts that develop faults due to negligence or improper use, incorrect maintenance, installation that does not comply with the manufacturer's instructions (always refer to the installation and use manual provided with the appliance).
• Incorrect dimensioning with regards to the use or faults in the installation or failure to adopt the necessary devices to guarantee proper execution.
• Improper overheating of the equipment, use of fuels not conforming to the types and quantities indicated in the instructions provided.
• Further damage caused by incorrect user interventions in an attempt to fix the initial fault.
• Worsening of the damage due to the continued use of the equipment by the user, once the defect has been noticed.
• In the presence of a boiler, any corrosions, incrustations or breaks caused by water flow, condensation, hardness or acidity of the water, improperly performed descaling treatments, lack of water, mud or limescale deposits.
• Inefficiency of chimneys, flues or parts of the plant affecting the equipment.
• Damage caused by tampering with the appliance, atmospheric agents, natural disasters, vandalism, electrical discharges, fires, faults in the electric and/or hydraulic system.
• Failure to have the stove cleaned on an annual basis by an authorised technician or qualified personnel will result in the loss of the warranty .
Also excluded from this guarantee are:
• Parts subject to normal wear such as gaskets, glass, claddings and cast iron grids, painted, chrome-plated or gilded parts, handles and electric cables, bulbs, indicator lights, knobs, all parts which can be removed from the hearth.
VEGA - SIRE 3 PLUS - DOGE 3 PLUS - SFERA 3 - SFERA 3 PLUS - PRINCE 3 - PRINCE 3 PLUS - GLOBE - TREND - ELISE 3 PLUS 5
EN
• Variations in colour of the painted or ceramic/serpentine parts and craquelure ceramics as they are natural characteristics of the material and product use.
• Masonry work.
• Plant parts (if present) not supplied by the manufacturer.
Any technical interventions on the product to eliminate the above-said defects and consequent damages must be agreed upon with the Technical Assistance Centre, who reserves the right to accept the relative appointment or not. However, said interventions will not be carried out under warranty but as technical assistance to be granted at part of any eventual and specific agreed conditions and in accordance with the fee in force for the work to be carried out.
The user will also be charged for any costs incurred to remedy the incorrect technical interventions, tampering or damage to the appliance, not attributable to original faults.
Save for the legal or regulatory limits, the guarantee does not cover the containment of atmospheric and acoustic pollution.
The company declines all liability for any damage which may be caused, directly or indirectly, to persons, animals or objects as a consequence of non compliance with any prescription specified in the manual, especially warnings regarding installation, use and maintenance of the appliance.
6
SPARE PARTS
For each repair or adjustment which should be necessary, please contact the dealer where you purchased your stove or your nearest Technical Assistance Service, specifying:
• Appliance model
• Serial number
• Type of problem
Use only original spare parts which you can find at our Technical Assistance Services.
7
WARNINGS FOR THE CORRECT DISPOSAL OF THE PRODUCT
The owner is the sole party responsible for demolishing and disposing of the product. This must be performed in compliance with laws related to safety and environmental protection in force in his/her country.
At the end of its working life, the product must not be disposed of as urban waste.
It must be taken to a special differentiated waste collection centre set up by the local authorities or to a retailer that provides this service.
Separating and recycling prevents potential negative effects on the environment and health (often caused by inappropriately disposing of product parts). It also allows materials to be recovered in order to obtain significant savings in energy and resources.
8
PACKAGING AND HANDLING
8.1
PACKAGING
• The packaging is made up of recyclable cardboard boxes according to RESY standards, recyclable expanded polystyrene inserts and wooden pallets.
• All packaging materials can be re-used for a similar use or eventually discharged as waste assimilable to the municipal solid ones, in accordance with current regulations.
• After having removed the packaging please assure you about the integrity of the product.
8.2
STOVE HANDLING
Both whether the stove is packed or not it is necessary to observe the following instructions for handling and transporting the stove from its sale point to its installation point and for any future movements:
• The stove must be handled with idoneous means paying attention to the existing safety regulations;
• do not turn the stove upside down and/or upset it on one side, but keep it in vertical position or as accorded with the constructor instructions;
• if the stove is made up of ceramic, stone, glass or any particularly fragile material components, all must be moved with the utmost care.
9
CHIMNEY FLUE
9.1
INTRODUCTION
This chapter about the Chimney Flue has been drawn up in cooperation with Assocosma (www.assocosma.org) and is based on European Standards (EN 15287 - EN 13384 - EN 1856 - EN 1443) and UNI 10683:2012.
It provides instructions for a good and correct execution of the chimney flue but it does not absolutely replace the current standards which the qualified manufacturer/installer should comply with.
6 VEGA - SIRE 3 PLUS - DOGE 3 PLUS - SFERA 3 - SFERA 3 PLUS - PRINCE 3 - PRINCE 3 PLUS - GLOBE - TREND - ELISE 3 PLUS
EN
9.2
CHIMNEY FLUE
Fig. 1 - Chimney Flues
LEGEND
1
2
3
4
5
Fig. 1 page 7
Chimney flue with insulated stainless-steel pipes
Chimney flue on the existing chimney
Inspection plug
Inspection door
≥ 3,5 mt
• The chimney flue or chimney is of great importance for the correct running of the heating appliance.
• It is fundamental that the chimney flue is perfectly built and always maintained with a perfect efficiency.
• The chimney flue must be sole (see Fig. 1 page 7 ) with insulated stainless-steel pipes (1) or installed on the existing chimney flue (2).
• Both this solutions must be endowed with an inspection plug (3) and/or an inspection door (4).
9.3
TECHNICAL FEATURES
Fig. 2 - Inclined roof
LEGEND
1
2
3
4
Fig. 2 page 7
Height over the ridge of the roof = 0,5 mt
Roof inclination ≥ 10°
90°
Measured distance at 90° from the roof surface = 1,3 mt
• The chimney flue must be sealed from fumes.
VEGA - SIRE 3 PLUS - DOGE 3 PLUS - SFERA 3 - SFERA 3 PLUS - PRINCE 3 - PRINCE 3 PLUS - GLOBE - TREND - ELISE 3 PLUS 7
EN
• It must have a vertical run without narrowing. It must be realized with fume and condensation resistant materials with thermal insulation and able to last against usual mechanical stresses.
It must be insulated to avoid condensation and to reduce fume cooling effects.
• The stove must be spaced out from fuels or flammable materials with an air gap or with insulating materials.
Check the distance with the chimney manufacturer.
• The chimney entrance must be placed in the same room where the appliance is installed or otherwise in the adjacent room and it must be provided with a solid and condensation collection chamber under the entrance, accessible through the sealed metal gate.
• Auxiliary exhaust fans cannot be installed neither along the chimney nor on the chimney pot.
• The inner section of the chimney flue can be round (the best one) or square and the jointed sides must have a minimum radius of 20 mm.
• The section dimension must be:
• minimun Ø100 mm (for stoves up to 8.5 kw)
• minimun Ø120 mm (for stoves to 9 kw up)
• recommended max Ø180 mm
• Made the efficiency of the chimney flue overhauled by an expert stove-repairer and if necessary cover the chimney flue with materials in compliance with current regulations.
• The flue system must be placed on the roof.
• The chimney flue must be provided CE in accordance with EN 1443 regulation. Please find attached an example of label:
Fig. 3 - Example of label
9.4
HEIGHT-DEPRESSION
The depression (draught) of a chimney flue depends also on its height. Check the depression with the values provided at FEATURES page 44 . Minimum height 3,5 meters.
9.5
MAINTENANCE
• The fumes extraction pipes (fumes conduit + chimney flue + chimney pot) must always be cleaned, scrubbed and checked by an expert stove-repairer, in compliance with current regulations, with the instructions of the stove-manufacturer and the directives of your insurance company.
• In case of doubts, please follow the most restrictive regulations.
• Have your chimney flue and chimney pot checked and cleaned by an expert chimney sweep at least once a week. The chimney sweep has to release a written declaration about the security of the system.
• Not cleaning compromise safety.
9.6
CHIMNEY POT
Fig. 4 - Anti-wind chimney pots
The chimney pot is important for the correct running of the heating appliance:
• We recommend using an anti-wind chimney pot, see Fig. 4 page 8 .
8 VEGA - SIRE 3 PLUS - DOGE 3 PLUS - SFERA 3 - SFERA 3 PLUS - PRINCE 3 - PRINCE 3 PLUS - GLOBE - TREND - ELISE 3 PLUS
EN
• The hole width for fumes exhaust must be the double of the chimney flue width and fitted in a way that the fume exhaust is assured also in case of wind.
• It should prevent the infiltration of rain, snow and animals.
• The outlet height in the atmosphere must be away from the reflux area caused by the roof structure or by obstacles laying nearby (see Fig. 2 page 7 ).
9.7
CHIMNEY COMPONENTS
LEGEND
1
2
3
6
7
8
4
5
9
10
Fig. 5 - Chimney components
Fig. 5 page 9
Chimney pot
Fume outlet
Chimney flue
Termal insulation
External wall
Chimney union
Fume pipe
Heat generator
Inspection door
T-union with inspection plug
VEGA - SIRE 3 PLUS - DOGE 3 PLUS - SFERA 3 - SFERA 3 PLUS - PRINCE 3 - PRINCE 3 PLUS - GLOBE - TREND - ELISE 3 PLUS 9
9.8
EN
EXTERNAL AIR INLET
Fig. 6 - Direct air inflow
LEGEND
1
2
Fig. 6 page 10
Room to ventilate
External air inlet
• The room must be endowed with an external air recycling for a good climate in your ambient.
• The air inflow from outside to the inner occurs directly, through an opening on the external wall of the room
(see Fig. 6 page 10 ).
• Bedrooms, garages, and store of flammable materials are excluded.
• The air inlet should have a total net surface of 80 sqcm 2 : the aforesaid surface is to widen if inside the room there are other activated appliances (for example: electric ventilators for foul air suction, cooker hoods, other stoves, etc...) which depress the environment.
• At switched on appliance it is necessary to check that the pressure fall between the room and the outside does not exceed 4,0 Pa value: if necessary widen the air inlet (EN 13384).
• The air inlet must be realized at a height close to the floor with an external grid against birds. In such a way it cannot be obstructed by any object.
• In case of installation with sealed-chamber the air inlet is not necessary.
9.9
COMBUSTIBLE AIR INLET FOR SEALED-CHAMBER INSTALLATION
10
Fig. 7 - Air inlet for sealed-chamber installation
LEGEND
1
2
Fig. 7 page 10
≥ 1,5 mt
≥ 0,3 mt
VEGA - SIRE 3 PLUS - DOGE 3 PLUS - SFERA 3 - SFERA 3 PLUS - PRINCE 3 - PRINCE 3 PLUS - GLOBE - TREND - ELISE 3 PLUS
EN
LEGEND
3-3
4
5
Fig. 7 page 10
Sectional view
Shield grid
Curve inlet to turn downwards
Check FEATURES page 44 if the purchased stove has a sealed-chamber. If the stove is endowed with a sealed-
• It is necessary to extract the air for combustion directly from outside.
• French standards require installation in double-walled flues (concentric system). The combustion air is drawn
• During installation step is necessary to verify the minimum distances required for the combustible air inlet as
• to the stove (see the underlying scheme).
effects: turn the curve inlet downwards, see Fig. 7 page 10 .
• Endow the curve with an external shield grid against birds in such a way that it cannot be obstructed by any object.
Check with your local authorities if exists any restrictive regulation regarding the combustible air inlet: if present, they must be applied
In some countries and/or regions the installation with sealed-chamber is obligatory: in case of doubt, please follow the most restrictive regulations.
How to connect to the stove in the sealed chamber with concentric system:
Fig. 8 - Phase1 Fig. 9 - Phase 2
• Original position with completely embedded tube (see Fig. 8 page 11 ).
• Pull out the tube for 2 cm (see Fig. 9 page 11 ).
• Insert the female tube ø 6 cm (see Fig. 10 page 11 ).
9.10
CHIMNEY FLUE CONNECTION
Fig. 10 - Phase 3
• The connection between the appliance and the chimney flue should be short in order to favor the draught
• The fume conduit should be equivalent or longer than the outlet joint ones (Ø 80 mm). sealed with the plug given with standard equipment.
SYSTEM TYPE
Minimum vertical length
Maximum length (with 1 union)
Maximum length (with 3 unions)
Maximum number of unions
Level section (minimum inclination 3%)
Installation at a height above 1200 m a.s.l.
Ø80 mm PIPE
1,5 mt
6,5 mt
4,5 mt
3
2 mt
NO
Ø100 mm PIPE
2 mt
10 mt
8 mt
3
2 mt
Obligatory
VEGA - SIRE 3 PLUS - DOGE 3 PLUS - SFERA 3 - SFERA 3 PLUS - PRINCE 3 - PRINCE 3 PLUS - GLOBE - TREND - ELISE 3 PLUS 11
EN
• Use a plate pipe for stoves of Ø80 mm or Ø100 mm depending on the type of system and with silicone gaskets.
• It is forbidden to use metal, fibre cement or aluminium flexible pipes.
• For change of direction it is obligatory always to use a union (with angle > 90°) with inspection plug which enables an easy periodic cleaning of the pipes.
• Please assure you that after the cleaning the inspection plugs are sealed with its efficient gasket.
• It is forbidden to connect more appliances to the same fume conduit.
• It is forbidden to convey in the same fume conduit exhausts from overhanging cooker hoods.
• It is forbidden to exhaust flue gases directly from the wall towards the outside and closed spaces also at open top.
• It is forbidden to connect any other appliance (wood stoves, cooker hoods, boilers, etc...).
• The fume conduit must be placed at a distance of minimum 500 mm from flammable or heat-susceptible components.
9.11
EXAMPLES OF CORRECT INSTALLATION
Fig. 11 - Example 1
LEGEND
1
2
3
4
Fig. 11 page 12
Insulating material
Reduction from Ø100 to Ø80 mm
Inspection plug
Minimum safety distance = 0,5 mt
• Chimney flue installation Ø100/120 mm with an enlarged drilling for pipe transit.
12
LEGEND
1
2
Fig. 12 - Example 2
Fig. 12 page 12
Insulating material
Inspection plug
VEGA - SIRE 3 PLUS - DOGE 3 PLUS - SFERA 3 - SFERA 3 PLUS - PRINCE 3 - PRINCE 3 PLUS - GLOBE - TREND - ELISE 3 PLUS
EN
LEGEND
3
4
5
6
Fig. 12 page 12
Chimney inspection entrance
Minimum safety distance = 0,5 mt
Inclination ≥ 3°
Level section ≤ 1 mt
• Old chimney flue with an inserted pipe of minimum Ø100/120 mm and with an external door which enables the chimney cleaning.
Fig. 13 - Example 3
LEGEND
1
2
3
Fig. 13 page 13
Insulating material
Inspection plug
Minimum safety distance = 0,5 mt
• External chimney flue entirely made up of insulated stainless steel pipes, i.e. with double wall of minimum
Ø100/120 mm: all must be firmly attached to the wall. For chimney against wind effects please (see Fig. 4 page 8 ).
• Ducting system through T-unions which enables an easy cleaning without disassembling the pipes.
We recommend to check with your chimney flue manufacturer the safety distances which must be respected and the type of insulating material. The aforesaid regulations are valid also for holes made on the wall (EN 13501 - EN 13063 - EN 1856 - EN 1806 - EN 15827).
10
FUEL
10.1
FUEL
• Use top-quality pellets because they have influence in the calorific value and in ash remains.
• Pellets features are: dimension Ø6-7mm (D06 Class), maximum lenght 40 mm, calorific value 5kWh/kg, humidity
≤ 10%, ash remains ≤ 0,7%, they must be correctly pressed and not much mealy, without sizing agents, resins and other additives (it is advisable to use pellets in compliance with the regulation EN14961-2 type ENplus-A1).
• Not adequate pellets cause a bad combustion, a frequent burning pot obstruction and exhaust conduits obstruction. Further it decreases the calorific value, soils the glass and increases consumptions and ash and unburnt granules quantity.
Humid pellets cause a bad combustion and running, so please assure you that they are stored in dry places and far at least one meter from the stove and/or any other source of heat.
• It is advisable to try different type of pellets available on the market and to choose that which gives the best performance.
• The use of bad quality pellets can damage the stove so that the warranty and manufacturer liability fall.
• On all our product are used high-quality materials such as stainless-steel, steel, cast iron, etc... These materials, before being sold on the market, are tested in laboratory, but despite this on the components which enable
VEGA - SIRE 3 PLUS - DOGE 3 PLUS - SFERA 3 - SFERA 3 PLUS - PRINCE 3 - PRINCE 3 PLUS - GLOBE - TREND - ELISE 3 PLUS 13
EN the pellets flow (auger) there could exist minimum differences in the material used, in roughness and porosity, which could generate usual variations in fuel transportation (pellets), causing a flame raising or drapping with a possible switching off at lower powers.
• Depending on the type of pellets it could be necessary a parameters adjustment, please contact an
Authorized Assistance Service.
11
INSTALLATION
11.1
INTRODUCTION
• The assembly position must be chosen depending on environment, outlet, chimney flue.
• Check with local authorities if there are any restrictive regulations which regard the combustible air inlet, room ventilation, fume exhaust system together with chimney flue and chimney pot.
• Check if there is the combustible air inlet.
• Check the probable presence of other stoves or appliances which could depress the room.
• Check at switched on stove if there is the presence of CO in the room.
• Check if the chimney has the necessary draught.
• Check if during the fume passage all has been executed in safety (probable fume losses and distances from flammable materials, etc.…).
• The installation of the appliance must enable an easy access for appliance, fume exhaust pipes and chimney flue cleaning.
• The installation must enable en easy access to the electric connection plug (see ELECTRIC CONNECTION page 22 ).
• To install more appliances, the external air inlet must be correctly dimensioned (see FEATURES page 44 ).
11.2
OVERALL DIMENSIONS
14
Fig. 14 - General dimensions: Vega / Trend
LEGEND
1
2
Fig. 14 page 14
54 cm
105 cm
VEGA - SIRE 3 PLUS - DOGE 3 PLUS - SFERA 3 - SFERA 3 PLUS - PRINCE 3 - PRINCE 3 PLUS - GLOBE - TREND - ELISE 3 PLUS
LEGEND
3
4
5
8
9
10
6
7
11
12
13
14
15
16
Fig. 14 page 14
54 cm
7,5 cm
8 cm
7,5 cm
8 cm
7,5 cm
22 cm
22 cm
32 cm
7,5 cm
34 cm
Exhaust fumes d.8 cm
Hole combustion air inlet d.6 cm
Ducting outlet
EN
Fig. 15 - General dimensions: Sire 3 Plus
LEGEND
1
2
3
6
7
8
4
5
9
10
11
12
13
Fig. 15 page 15
54,4 cm
104,8 cm
52,3 cm
7,1 cm
5,8 cm
7,1 cm
5,8 cm
7,7 cm
21,7 cm
21,6 cm
30,3 cm
7,7 cm
34 cm
VEGA - SIRE 3 PLUS - DOGE 3 PLUS - SFERA 3 - SFERA 3 PLUS - PRINCE 3 - PRINCE 3 PLUS - GLOBE - TREND - ELISE 3 PLUS 15
EN
LEGEND
14
15
16
Fig. 15 page 15
Exhaust fumes d.8 cm
Hole combustion air inlet d.6 cm
Ducting outlet
Fig. 16 - General dimensions: Doge 3 Plus
11
12
13
14
9
10
7
8
15
16
LEGEND
1
2
5
6
3
4
Fig. 16 page 16
55,4 cm
105,6 cm
54 cm
8,3 cm
8,5 cm
8,3 cm
8,5 cm
8,3 cm
21,7 cm
22,2 cm
30,3 cm
8,3 cm
34 cm
Exhaust fumes d.8 cm
Hole combustion air inlet d.6 cm
Ducting outlet
16 VEGA - SIRE 3 PLUS - DOGE 3 PLUS - SFERA 3 - SFERA 3 PLUS - PRINCE 3 - PRINCE 3 PLUS - GLOBE - TREND - ELISE 3 PLUS
Fig. 17 - General dimensions: Sfera 3 / Sfera 3 Plus / Globe
LEGEND
1
2
3
6
7
4
5
10
11
12
8
9
13
Fig. 17 page 17
53,6 cm
104 cm
57 cm
45°
5,5 cm
30,3 cm
22,7 cm
11,7 cm
5,5 cm
21,7 cm
Exhaust fumes d.8 cm
Hole combustion air inlet d.6 cm
Ducting outlet (Sfera 3 Plus model)
VEGA - SIRE 3 PLUS - DOGE 3 PLUS - SFERA 3 - SFERA 3 PLUS - PRINCE 3 - PRINCE 3 PLUS - GLOBE - TREND - ELISE 3 PLUS 17
EN
EN
Fig. 18 - General dimensions: Prince 3 / Prince 3 Plus
LEGEND
1
2
3
4
9
10
11
12
7
8
5
6
13
14
15
16
Fig. 18 page 18
54 cm
105 cm
54 cm
7,5 cm
8 cm
7,5 cm
8 cm
7,5 cm
22 cm
22 cm
32 cm
7,5 cm
34 cm
Exhaust fumes d.8 cm
Hole combustion air inlet d.6 cm
Ducting outlet (Prince 3 Plus model)
18 VEGA - SIRE 3 PLUS - DOGE 3 PLUS - SFERA 3 - SFERA 3 PLUS - PRINCE 3 - PRINCE 3 PLUS - GLOBE - TREND - ELISE 3 PLUS
Fig. 19 - General dimensions: Elise 3 Plus
LEGEND
1
2
3
4
9
10
11
12
13
7
8
5
6
Fig. 19 page 19
65 cm
108 cm
60,3 cm
45°
5,5 cm
30,3 cm
22,7 cm
11,7 cm
8,2 cm
22 cm
Exhaust fumes d.8 cm
Hole combustion air inlet d.6 cm
Ducting outlet
VEGA - SIRE 3 PLUS - DOGE 3 PLUS - SFERA 3 - SFERA 3 PLUS - PRINCE 3 - PRINCE 3 PLUS - GLOBE - TREND - ELISE 3 PLUS 19
EN
EN
11.3
GENERAL INSTALLATION
Fig. 20 - General installation
LEGEND
1
2
3
4
Fig. 20 page 20
Stove
Minimum lateral distance = 300 mm
Minimum rear distance = 200 mm
Minimum front distance = 1000 mm
It is obligatory to install the stove away from walls and/or pieces of furniture, with a minimum air flow of 300 mm on the sides and 200 mm on the back, to enable an eficient appliance cooling and a good distribution of heat in the room (see Fig. 20 page 20 ).
If the walls are made up of flammable materials, check the safety distances (see Fig. 20 page 20 ).
At maximum power check that the wall temperature does not ever exceed 80°C. If it would be necessary please install a fire resistant plate on the concerned walls.
In some countries also masonring load-bearing walls are considered flammable.
11.4
FRONTAL PANEL ASSEMBLY (VEGA / TREND / PRINCE
3
/ PRINCE
3
PLUS MODELS)
For frontal panel installation, proceed as follows:
Fig. 21 - Frontal panel assembly Fig. 22 - Frontal panel position Fig. 23 - Frontal panel fixing
• Hook the frontal panel cogs at its specific holes (see Fig. 21 page 20 ).
• Place the frontal panel in the correct position (see Fig. 22 page 20 ).
• Fix the frontal panel by tightening two screws in the lower part (see Fig. 23 page 20 ).
11.5
TILE ASSEMBLY (SIRE
3
PLUS MODEL)
Proceed as follows to assemble the tiles:
20 VEGA - SIRE 3 PLUS - DOGE 3 PLUS - SFERA 3 - SFERA 3 PLUS - PRINCE 3 - PRINCE 3 PLUS - GLOBE - TREND - ELISE 3 PLUS
EN
Fig. 24 - Profile and tiles Fig. 25 - Tighten the profile to the tiles Fig. 26 - Fixing to stove
• Assemble the galvanised profile to the tiles (see Fig. 24 page 21 and Fig. 25 page 21 ).
• Connect the tile teeth to the stove (see Fig. 26 page 21 ).
11.6
PANELS ASSEMBLY (SFERA
3
/ SFERA
For panels installation, proceed as follows:
3
PLUS MODELS)
Fig. 27 - Panels assembly Fig. 28 - Panel with hole assembly (Sfera 3
Plus model)
Fig. 29 - Open the hole (Sfera 3 Plus model)
• Hook the panels at its specific cogs (see Fig. 27 page 21 ).
• Hook the punched panel at its specific cogs at the back of stove (see Fig. 28 page 21 ).
• For Sfera 3 Plus model with lateral duction, open the hole as shown in Fig. 29 page 21 .
Fig. 30 - Place the bracket Fig. 31 - Screw the bracket
VEGA - SIRE 3 PLUS - DOGE 3 PLUS - SFERA 3 - SFERA 3 PLUS - PRINCE 3 - PRINCE 3 PLUS - GLOBE - TREND - ELISE 3 PLUS 21
EN
• Place the bracket between the colored panels, in the upper part, to lock the sides (see Fig. 30 page 21 ).
• Blocking the bracket with the screw (see Fig. 31 page 21 ).
11.7
FRONTAL PANEL ASSEMBLY (VEGA STONE MODEL)
For frontal panel installation, proceed as follows:
Fig. 32 - Place the stones Fig. 33 - Fasten the stones
• Place the stones on the frame (see Fig. 32 page 22 ).
• Fasten the stones with the screws behind the frame (see Fig. 33 page 22 ).
• Assembled frame (see Fig. 34 page 22 ).
Fig. 34 - Assembled frame
Fig. 35 - Frontal panel assembly Fig. 36 - Frontal panel position Fig. 37 - Frontal panel fixing
• Hook the frontal panel cogs at its specific holes (see Fig. 35 page 22 ).
• Place the frontal panel in the correct position (see Fig. 36 page 22 ).
• Fix the frontal panel by tightening two screws in the lower part (see Fig. 37 page 22 ).
11.8
ELECTRIC CONNECTION
Warning: the appliance must be installed by an authorized technician!
• The electric connection occurs through a cable with plug put in an electric socket which is able to support charge and tension specific of every model, as described in the technical datas table (see FEATURES page
44 ).
• The plug must be easily accessible when the appliance is installed.
• Please further assure you that your network is endowed with an efficient earth connection: if it does not exist
22 VEGA - SIRE 3 PLUS - DOGE 3 PLUS - SFERA 3 - SFERA 3 PLUS - PRINCE 3 - PRINCE 3 PLUS - GLOBE - TREND - ELISE 3 PLUS
EN or if it is not efficient, please endow you with one in compliance with the law.
• Connect the supply cable first on the back of the stove (see Fig. 38 page 23 ) and then at a wall electric socket.
Fig. 38 - Electric socket with master switch
• The master switch O/I (see Fig. 38 page 23 ) is to open only to switch the stove on, otherwise it is advisable to keep it off.
• Do not use extension cables.
• If the feeder cable is damaged, it must be replaced by an authorized technician.
• When the stove is not going to be used for a long period of time, it advisable to remove the plug from the socket on the wall.
11.9
CONNECTION TO THE EXTERNAL THERMOSTAT
The stove works through a thermostat probe placed in its inner. If you desire, the stove can be connected to an external room thermostat. This operation must be executed by an authorized technician.
• External thermostat: "SET TEMP ROOM" a temperature which is round 7°C.
• External chronothermostat: "SET TEMP ROOM" a temperature which is round 7°C and desable the chrono functions from the menu 03-01 "CHRONO ENABLE" ("OFF").
11.10
VENTILATION
• The stove is endowed with a ventilation system.
• The air blown from fans keeps the appliance at a low temperature range in order to avoid high stresses to the materials which make it up.
• Do not cover the hot air outlet slits with any object to avoid stove’s overheating!
• The stove is not suitable for food cooking.
Fig. 39 - Do not cover air slits
11.11
HOT AIR DUCTING SYSTEM (VEGA / TREND / SIRE
3
PLUS / DOGE
3
PLUS / SFERA
3
PLUS /
ELISE
3
PLUS / PRINCE
3
PLUS MODELS)
The stove is fitted with 1 hot air outlet.
VEGA - SIRE 3 PLUS - DOGE 3 PLUS - SFERA 3 - SFERA 3 PLUS - PRINCE 3 - PRINCE 3 PLUS - GLOBE - TREND - ELISE 3 PLUS 23
EN
Fig. 40 - Upper pipe position Fig. 41 - Upper hot air outlet
Fig. 42 - Back pipe position Fig. 43 - Back hot air outlet
• The hot air can be forced in ducts in the upper part (see Fig. 40 page 24 and Fig. 41 page 24 ).
• Or make the air exit from the rear (see Fig. 42 page 24 and Fig. 43 page 24 ).
Fig. 44 - Ducting system example
• If the stove is not fitted with ducting system, it provide a hot air capacity ranging from a minimum of 61 m 3 /h
24 VEGA - SIRE 3 PLUS - DOGE 3 PLUS - SFERA 3 - SFERA 3 PLUS - PRINCE 3 - PRINCE 3 PLUS - GLOBE - TREND - ELISE 3 PLUS
EN to a maximum of 130 m 3 /h with a temperature ranging between 90°C and 136°C.
• For the ducting system, we recommend using a pipe with a maximum length of 6 mt and up to three 90° elbows in order to maintain hot air temperature.
• Use pipes with smooth internal surface and a diameter of 80 mm.
• Fit the pipe with insulating material if it passes through a cold wall.
• The outlet must be protected by a grid with wide mesh and a minimum total surface area of 40 cm 2 .
• If the pipes used are longer than 6 mt, the air capacity ranges from a minimum of 58 m 3 /h to a maximum of
883 m 3 /h and the temperature from 65°C to 99°C. (These values refer to the laboratory used for the tests. The room where the stove is installed may register different values both in terms of capacity and temperature).
• If you wish to increase air capacity, install at the end of the pipe a small wall-mounted fan with a capacity exceeding 130 m 3 /h. The installation must be carried out by an authorised technician.
• According to the factory parameters, 1/2 of the generated heat is conveyed into the room where the stove is installed, while the remaining 1/2 are conveyed through the left ducting pipe system.
• Balance heat output with air capacity to obtain the best performance (see FAN ADJUSTMENT page 29 ).
The operation above must be carried out by an authorised technician.
11.12
USING THE STOVE WITHOUT DUCTING
The stove can be used without ducting the air to other environments.
In this case, assemble the environment diffuser in the stove's rear (see Fig. 45 page 25 ).
Fig. 45 - Diffuser assembly
12
USE
12.1
INTRODUCTION
To have the best performance with the lowest consumption please follow the here descripted instructions.
• The lightning of the pellets occurs very easily if the installation is correct and if the chimney flue is efficient.
• Switch on the stove at Power 1 for at least 2 hours in order to enable the materials which make up the boiler and the fireplace to adjust the inner springing stress.
• By using the stove the varnish inside the combustion chamber could be subjected to alterations. This occurrence can be attributed to different reasons: an excessive stove overheating, the presence of chemical agents in bad quality pellets, bad chimney draught, etc. Therefore varnish endurance in the combustion chamber cannot be guarantee.
Oily plant waste and lacquers can cause smells and smoke during the first working hours: it is advisable to ventilate the room because they could be noxious to people and animals.
Set values from 1 to 5 are defined by the manufacturer and they can be changed only by an authorized technician.
VEGA - SIRE 3 PLUS - DOGE 3 PLUS - SFERA 3 - SFERA 3 PLUS - PRINCE 3 - PRINCE 3 PLUS - GLOBE - TREND - ELISE 3 PLUS 25
EN
12.2
CONTROL PANEL
PANEL ELEMENT DESCRIPTION
P1 and P2: when in set temperature mode, they are useful to increase or decrease the thermostat value from min. 6°C to max 40°C. Keeping pressed P2 key it is possible to see the fume temperature at the exhaust. Both have programming functions.
P3: it enables to enter set temperature and User and Technician parameters menu.
P4: switching on and off, alarm reset and exit from programming.
P5 and P6: increase and decrease the calorific power from 1 to 5:
Chrono: active time programming.
Ignition plug: active ignition.
Auger: active.
Fume fan: active.
-
Exchanger fan: active.
Alarm: active.
26
Fig. 46 - LCD control display
LEGEND
1
2
3
4
5
Fig. 46 page 26
Time
Power
State
Message
Temperature
VEGA - SIRE 3 PLUS - DOGE 3 PLUS - SFERA 3 - SFERA 3 PLUS - PRINCE 3 - PRINCE 3 PLUS - GLOBE - TREND - ELISE 3 PLUS
EN
12.3
USER MENU
By once pressing P3 key you can hace access to user parameter controlling. To let them slide press P5 and P6 keys. They are:
POS.
1
2
3
4
5
6
7
8
9
10
REFERENCE
FAN ADJUST
(supplementary)
SET CLOCK
SET CHRONO
DESCRIPTION
Press once P3: Nr2 fan appears (for one ducting) or Nr2 and Nr3 fans appears (for double ducting). See FAN ADJUSTMENT page 29 .
Set date and time. The board is provided with a lithium battery which enables a clock autonomy of 3/5 years. See CLOCK SETTING page 28 .
Press once P3: "CHRONO ENABLE" appears. Press P3 again and with P1 and P2 put in "OFF" or "ON". For daily, week-end or weekly programming, see DAILY PROGRAMMING page 28 .
CAUTION: do not active if STAND-BY function is active!
SELECT
LANGUAGE
Press once P3 key and with P1 and P2 keys select the desired language.
STAND-BY MODE
It activates a function which, if the set ambient temperature has been exceeded for more then 10 minutes, start the switching off phase up. If the ambient temperature has fall at more than 2°C, the stove will restart automatically up, starting from START UP page 27 .
Press once P3 key and with P1 and P2 keys put in "OFF" or "ON". CAUTION: do not activate if
CHRONO function is active!
BUZZER MODE
(audio alarm)
Press once P3 key and with P1 and P2 keys put in "OFF" or "ON".
INITIAL LOAD
When the stove has its first ignition, the auger is completely empty. If it should be necessary do a precharge by pressing P3 key, then P1 key for starting up and P4 key for stop.
STOVE STATE
It shows all parameters connected to the stove state: this is a menu for the Authorized
Techinician
TECHNICA SETTING Only for the Authorized Technician.
FLAME SETTING It enables to set the flame dipending on the draught of the chimney flue.
12.4
START UP
We remind you that the first ignition must be carried out by a specialized and authorixed technician who will check that all is installed in compliance with current regulations and checks the efficiency.
• If inside the combustion chamber there are booklets, manuals, etc..., remove them.
• Check if the door is correctly closed.
• Check if the stove is correctly inserted in the electric socket.
• Before switching the stove on, assure you the burning pot is clean.
• To start the stove up, keep pressed P4 key for an instant till it will be shown "START" and "PREHEAT WAIT": the preheating of the ingnition resistance starts. After 2 minutes about, it will be shown "PELLET LOAD, WAITING FIRE", in this phase the auger loads the pellet and the heating of the resistance continues. When the temperature is sufficiently high (after 7-10 minutes about), the ignition is considered as happened and on the display shows
"FIRE PRESENT".
• Completed the phase "FIRE PRESENT", the control unit enter the "WORK" phase showing the set calorific power and ambient temperature. It is in this phase that P5 and P6 keys settle the stove power from 1 to 5. If the value of the ambient temperature exceeds the limit set on the keyboard on the temperature setting, the calorific power will be carried at the minimum showing "WORK, MODULAT". When the ambient temperature turns back below the set temperatur, the stove turns back to the set power.
12.5
STOVE ADJUSTMENT
The stove is adjusted according to the chimney flue and used pellets datas, as per technical characteristics (see
FEATURES page 44 ). If the datas do not correspond, the authorized technician can adjust the stove.
• If the pellet is small in size and with a greater calorific power, (for example: encrusted burning pot), the pellet drop must be decreased from the menu "FLAME SETTING", press P3 "PELLET TYPE", press P3 again "PELLET LOAD" and with P2 key decrease the pellet quantity from -1 (which is -2%) till -9 (which is -18%).
• If the chimney flue has a lower draught (for example: weak flame, sooty glass) the revolutions of the geared motor must be increased from the menu "FLAME SETTING", press P5 "CHIMNEY TYPE", press P3 "FUME-EXT,
CHIMNEY" and with P1 key increase the fume fan revolutions from +1 (which is +5%) till +9 (which is +30%).
• If the chimney flue has a greater draught (for example: because of pellets fall on the burning pot) decrease the fume fan revolutions from -1 to -9.
VEGA - SIRE 3 PLUS - DOGE 3 PLUS - SFERA 3 - SFERA 3 PLUS - PRINCE 3 - PRINCE 3 PLUS - GLOBE - TREND - ELISE 3 PLUS 27
EN
Pay attention if the value is positive or negative..
12.6
FAILED IGNITION
If the pellets do not burn, the failed ignition will be indicated by the alarm "FAILED IGNITION".
• If the room temperature is lower than 10°C, the plug is not able to bear the ignition stage. To support it please insert some pellets in the burning pot and a piece of burning firelighter igniter material on the pellets (for example firelighters cubes).
• Too much pellets in the burning pot, or humid pellet, or sooty burning pot make ignition difficult and create dense white smoke which is harmful to health and can cause explosions on the combustion chamber. It is therefore necessary not to stand in front of the stove during ignition stage if dense white smoke is present.
If after some months the flame appears weak and/or orange colored or the glass tends to blackens and the burning pot to become encrusted, clean the stove, clean the fume conduit and the chimney flue.
12.7
POWER FAILURE
• After a black-out lower than 5 seconds, the stove turns back to the power which was settled.
• After a black-out of more than 5 seconds, the stove enters the "COOLING WAIT" phase. Completed this phase, it starts automatically up with the different phases (see START UP page 27 ).
12.8
TEMPERATURE SETTING
• To modify the ambient temperature it is sufficient to press P1 and P2 keys according to the desired temperature inside the menu "SET TEMP ROOM".
• To see the set temperature, press once P1 key.
12.9
FUME TEMPERATURE
To check the fume temperature at the exhaust it is sufficient to keep pressed P2 key.
12.10
SWITCHING OFF
To switch the stove off, keep pressed P4 key: the display shows "FINAL CLEANING". After about 10 minutes, also the fume fan switches off (this happens always, independently if the stove is hot or cold). Then "OFF" will be shown.
12.11
CLOCK SETTING
• Press P3 key and then P5 key till underlining "SET CLOCK" menu (02).
• Press once P3 (DAY) and with P1 and P2 keys select the day of the week (Monday, Tuesday, Wednesday,
Thursday, Friday, Saturday, Sunday).
• Press for the second time P3 key (HOURS) and with P1 and P2 keys set the hour.
• Press for the third time P3 key (MINUTES) and with P1 and P2 keys select the minutes. Press for the fourth time
P3 key (DAY) and with P1 and P2 keys select the day of the month (1,2,3...29,30,31).
• Press for the fifth time P3 key (MONTH) and with P1 and P2 keys select the month:
• Press for the sixth time P3 key (YEAR) and with P1 and P2 keys select the year.
• To exit from the programme press P4 twice.
12.12
DAILY PROGRAMMING
It allows to enable, disable and settle the daily chronothermostat functions.
Press P3 key and then P5 key till the menu "SET CHRONO" Press once P3 key and with P5 and P6 keys select the
"PROGRAM DAY". Press once P3 till finding "CHRONO DAY". With P1 and P2 keys put in "OFF" or "ON". It is possible to set two working times delimited by the set times.
After "CHRONO DAY":
• Press P5: the display shows "START 1", with P1 and P2 keys set the ignition time value or put in "OFF".
• Press P5: the display shows "STOP 1", with P1 and P2 keys set the switching off time value or put in "OFF".
• Press P5: the display shows "START 2", with P1 and P2 keys set the ignition time value or put in "OFF".
• Press P5: the display shows "STOP 2", with P1 and P2 keys set the switching off time value or put in "OFF".
• Press P4 key three times to exit from the menu.
12.13
WEEKEND PROGRAMMING
It allows to enable, disable and settle the chronothermostat functions during saturday and sunday.
Press P3 key and then P5 key till the menu "SET CHRONO". Press once P3 key and with P5 and P6 keys select
"PROGRAM WEEKEND". Press once P3 till finding "CHRONO WEEKEND". With P1 and P2 keys put in "OFF" or "ON". It
28 VEGA - SIRE 3 PLUS - DOGE 3 PLUS - SFERA 3 - SFERA 3 PLUS - PRINCE 3 - PRINCE 3 PLUS - GLOBE - TREND - ELISE 3 PLUS
EN is possible to set two working times delimited by the set times and valid only for saturday and sunday.
After "CHRONO WEEKEND";
• Press P5: the display shows "START 1 WEEKEND", with P1 and P2 keys set the ignition time value or put in "OFF".
• Press P5: the display shows "STOP 1 WEEKEND", with P1 and P2 keys set the switching off time value or put in
"OFF".
• Press P5: the display shows "START 2 WEEKEND", with P1 and P2 keys set the ignition time value or put in "OFF".
• Press P5: the display shows "STOP 2 WEEKEND", with P1 and P2 keys set the switching off time value or put in
"OFF".
• Press P4 key three times to exit from the menu.
12.14
WEEKLY PROGRAMMING
It allows to enable, disable and settle the weekly hermostat functions (saturday and sunday included).
Press P3 key and then P5 key till the menu "SET CHRONO". Press once P3 key and with P5 and P6 keys select
"PROGRAM WEEK". Press once P3 till finding "WEEKLY CHRONO". With P1 and P2 keys put in "OFF" or "ON". It is possible to set four working times delimited by the set times.
After "WEEKLY CHRONO":
Press P5: the display shows "START PROG-1", with P1 and P2 keys insert the ignition time value or put in "OFF".
Press P5: the display shows "STOP PROG-1", with P1 and P2 insert the switching off value or put in "OFF".
• Press P5: the display shows "MONDAY PROG-1", with P1 and P2 keys set "ON" or "OFF".
• Press P5: the display shows "TUESDAY PROG-1", with P1 and P2 keys set "ON" or "OFF".
• Press P5: the display shows "WEDNESDA PROG-1", with P1 and P2 keys set "ON" or "OFF"".
• Press P5: the display shows "THURSDAY PROG-1", with P1 and P2 keys set "ON" or "OFF".
• Press P5: the display shows "FRIDAY PROG-1", with P1 and P2 keys set "ON" or "OFF".
• Press P5: the display shows "SATURDAY PROG-1", with P1 and P2 keys set "ON" or "OFF"".
• Press P5: the display shows "SUNDAY PROG-1", with P1 and P2 keys set "ON" or "OFF".
Now press P5 and repeat all the previous instructions for Prog-2, Prog-3, Prog-4.
• To exit press three times P4.
12.15
FAN ADJUSTMENT
Press P3 button in menu 1 “FAN ADJUST”: the fan menus no.2 will open.
Press P1 to adjust fan no. 2.
Function “A” activates the default fan data. (For example: heat output 1 activates default rotations at heat output 1, heat output 2 activates default rotations at heat output 2, etc.).
With function “1” or "2" or "3" or "4" or "5" the fan is forced to work at the selected output. (For example: by setting
“2”, even if the fan is set to heat output 5 it will work as if set to heat output “2”, etc.).
If the stove is set to maximum heat output 5 and the fans to minimum output 1, this may cause overheating and the “THERMAL SAFETY” alarm to go off.
12.16
PELLET SUPPLY
Fig. 47 - Wrong opening of the pellets bag Fig. 48 - Right opening of the pellets bag
It is necessary to avoid to fill the hopper with the pellet when the stove is running.
• Do not get the bag of pellet in contact with hot stove surfaces.
• Do not empty the hopper with remaining fuels (unburnt pellet) from the burning pot coming from ignition waster.
VEGA - SIRE 3 PLUS - DOGE 3 PLUS - SFERA 3 - SFERA 3 PLUS - PRINCE 3 - PRINCE 3 PLUS - GLOBE - TREND - ELISE 3 PLUS 29
EN
12.17
REMOTE CONTROL
• The stove can be operated through a remote control.
• Operation requires 1 CR 2025 Lithium battery.
Used batteries contain metals which are harmful for the environment; they must therefore be disposed of separately in the special containers.
LEGEND
Button 1
Button 2
Button 3
Button 4
Button 5
Button 6
Fig. 49 - Remote control
Fig. 49 page 30
Increase the desired temperature
Decrease the desired temperature
On / off
Menu
Decrease the power level from 5 to 1
Increase the power level from 1 to 5
13
SAFETY SYSTEM
13.1
INTRODUCTION
Safety devices are used to prevent and avoid the risk of damages to people, animales and objects.
It is forbidden to execute repearing by no authorized personnel otherwise the warranty and the manufacturer liability fall.
13.2
"BLACK OUT" ALARM
"ACTIVE ALARM" "AL 1 - BLACK OUT": current breaking during ignition.
• Reset the error with P4 key. The stove carries out the phase "FINAL CLEANING" and then is in "OFF":
• Clean the burning pot and start the stove up again with P4 key.
13.3
"EXHAUST PROBE" ALARM
To the exhaust is connected a probe which contantly controls the temperature during working time.
"ACTIVE ALARM" "AL 2 - EXHAUST PROBE": the probe is damaged or disconnected.
• Reset the error with P4 key. The stove carries out the phase "FINAL CLEANING" and the is in "OFF".
• Check the type of glitch as ALARMS page 38 .
• Clean the burning pot and start the stove up again with P4 key.
13.4
"HOT EXHAUST" ALARM
If the fume probe registers a temperature at the exhaust higher then 180°C, the display shows "HOT EXHAUST".
Then the combustible (pellet) drop will be decreased at phase 1.
This function has the aim to bring the values within preset values. If for any reason the temperature would not decreas but increase, at 200°C the display shows "ACTIVE ALARM" "AL 3 - HOT EXHAUST" and the stove start the switching off phase up.
30 VEGA - SIRE 3 PLUS - DOGE 3 PLUS - SFERA 3 - SFERA 3 PLUS - PRINCE 3 - PRINCE 3 PLUS - GLOBE - TREND - ELISE 3 PLUS
EN
• Reset the error with P4 key. The stove carries out the phase "FINAL CLEANING" and the is in "OFF".
• Check the type of glitch as ALARMS page 38 .
• Clean the burning pot and start the stove up again with P4 key.
13.5
"FAN FAILURE" ALARM
"ACTIVE ALARM" "AL 4 - FAN FAILURE": the fume fan is out of order.
• Reset the error with P4 key. The stove carries out the phase "FINAL CLEANING" and the is in "OFF".
• Check the type of glitch as ALARMS page 38 .
• Clean the burning pot and start the stove up again with P4 key.
13.6
"FAILED IGNITION" ALARM
"ACTIVE ALARM" "AL 5 - FAILED IGNITION": the temperatureis not sufficient for ignition.
• Reset the error with P4 key. The stove carries out the phase "FINAL CLEANING" and the is in "OFF".
• Check the type of glitch as ALARMS page 38 .
• Clean the burning pot and start the stove up again with P4 key.
13.7
"NO PELLET" ALARM
If the fume probe registers a temperature at the exhaust lower than the minimum threshold and the display shows "ACTIVE ALARM" "AL 6 - NO PELLET".
• Reset the error with P4 key. The stove carries out the phase "FINAL CLEANING" and the is in "OFF".
• Full the hopper.
• Clean the burning pot and start the stove up again with P4 key.
13.8
"THERMAL SAFETY" ALARM
In the hopper is installed an automatic thermostat which activates if the temperature excursion exceeds the allowed limits, so avoiding the possibility that the pellet inside the hopper could burn because of overheating.
"ACTIVE ALARM" "AL 7 - THERMAL SAFETY": the thermostat stops the power supply to the auger.
• Reset the error with P4 key. The stove carries out the phase "FINAL CLEANING" and then is in "OFF".
• Check the type of glitch as ALARMS page 38 .
• Unscrew the black cap, press the button and screw the cap again.
• Clean the burning pot and start the stove up again with P4 key.
13.9
"FAILURE DEPRESS" ALARM
To the boiler is connected a pressostat which control the depression and in some stove models on the fire door id installed a microswitch which registers the opening.
"ACTIVE ALARM" "AL 8 - FAILURE DEPRESS": the pressostat and/or fire door which is not correctly closed stops the power supply to the auger.
• Reset the error with P4 key. The stove carries out the phase "FINAL CLEANING" and then is in "OFF".
• Check the type of glitch as ALARMS page 38 .
• Unscrew the black cap, press the button and screw the cap again.
• Clean the burning pot and start the stove up again with P4 key.
13.10
"DOOR OPEN" ALARM
On the lower part of the fire door is installed a microswitch which detects the opening.
"ACTIVE ALARM" "AL 9 - DOOR OPEN": it means that the fire door is not correctly closed.
• Reset the error pressing P4 key. The stove carries out a "FINAL CLEANING" and "OFF" appears.
• Check the type of failure as shown on ALARMS page 38 .
• Clean the burning pot and start the stove up again pressing P4 key.
14
MAINTEINANCE
14.1
INTRODUCTION
For a long working life of the stove, have a periodic cleaning of the stove as described in the following paragrafs.
• Fume outlet pipes (fume conduit + chimney flue + chimney pot) must always be cleaned, scrubbed and checked by an authorized technician in compliance with local regulations, with the instructions of the manufacturer and those of your insurance company.
• If there are no local regulations and no instruction from your insurance company, it is necessary to have your fume pipe, chimney flue and chimney pot cleaned at least once a year.
• It is also necessary to have the combustion chamber, motors and fans cleaned and to have the gaskets and the electronical elements checked at least once a year.
VEGA - SIRE 3 PLUS - DOGE 3 PLUS - SFERA 3 - SFERA 3 PLUS - PRINCE 3 - PRINCE 3 PLUS - GLOBE - TREND - ELISE 3 PLUS 31
EN
All these operations must be planned in time with your Autorized Technical Assistance
Service.
• After a long ineffective time, before turning on the stove check if there are obstructions in the fume exhaust.
• If the stove had been using continuously and intensely, the whole system (chimney included), must be cleaned and checked more frequently.
• In case of replacement of damaged pieces please ask for the original spare part at the Autorized Retailer.
14.2
BURNING POT AND ASH TRAY CLEANING
The burning pot and ash tray cleaning must be executed at least every 2 days.
• Open the door.
Fig. 50 - Burning pot extraction Fig. 51 - Ash tray extraction Fig. 52 - Burning pot cleaning
• Extract the burning pot (see Fig. 50 page 32 ) from its seat and empty it from the ash.
• Extract the ash tray (see Fig. 51 page 32 ) and empty it from the ash.
• If necessary clean with a pointed object the holes obstructed by encrustations (see Fig. 52 page 32 ).
Fig. 53 - Burning pot box cleaning Fig. 54 - Cleaning with a brush
• Clean and drain away the burning pot box and ash tray box from ash which has accumulated in its inner (see
Fig. 53 page 32 ).
• Clean also the hole for pellet drop with a brush (see Fig. 54 page 32 ).
• The ash remains must be poured in a metal container with a sealed lid and this container must never get in touch with combustible materials (for example put on a wooden floor), as the inner ash keeps the embers firing for a long time.
• Only when the embers are off the ash coul be poured in the organic waste.
• Pay attention if the flame becomes red colured, if it is weak or if black smoke creates in the inner: in this case the burning pot is encrusted and needs to be cleaned. If it is broken, it must be replaced.
32 VEGA - SIRE 3 PLUS - DOGE 3 PLUS - SFERA 3 - SFERA 3 PLUS - PRINCE 3 - PRINCE 3 PLUS - GLOBE - TREND - ELISE 3 PLUS
EN
14.3
HOPPER AND AUGER CLEANING
Per each pellets supply, check the probable presence of meal, sawdust and other remanins on the hopper bottom. If present, they must be removed with the aid of a vacuum cleaner (see Fig. 55 page 33 ).
Fig. 55 - Hopper and auger cleaning
The hand rejector grid must not ever be removed fron its housing. Clean the hopper bottom and the visible part of the auger exclusively as shown in the picture (see Fig. 55 page 33 ).
14.4
FUME CHAMBER AND FUME PASSAGES CLEANING
Every season (or every 1500 operation hours) the fume chamber and the fume passages cleaning must be executed.
• Remove the sides of the stove according to the model:
VEGA / SIRE 3 PLUS / PRINCE 3 / TREND / PRINCE 3 PLUS : remove the side upper screws (see Fig. 56 page 33 and
Fig. 57 page 33 ), then remove the side completely (see Fig. 58 page 33 ).
Fig. 56 - Removing the upper screw Fig. 57 - Removing the rear screw Fig. 58 - Removing the side
DOGE 3 PLUS : remove the lower screws from the central panel (see Fig. 59 page 34 ) and then remove the panel (see Fig. 60 page 34 ).
VEGA - SIRE 3 PLUS - DOGE 3 PLUS - SFERA 3 - SFERA 3 PLUS - PRINCE 3 - PRINCE 3 PLUS - GLOBE - TREND - ELISE 3 PLUS 33
EN
Fig. 59 - Removing the lower screws
SFERA 3 / SFERA 3 PLUS: unhook the side panels (see Fig. 61 page 34 ).
Fig. 60 - Removing the central panel
Fig. 61 - Sfera 3 / Sfera 3 Plus: unhook the side panels.
GLOBE : Remove the screws from the upper cover (see Fig. 62 page 34 and Fig. 63 page 34 ), and then remove the latter (see Fig. 64 page 34 ). Unhook the lateral sides (see Fig. 65 page 34 ).
Fig. 62 - Cover 1 screw removal Fig. 63 - Cover 2 screw removal
34
Fig. 64 - Remove the cover Fig. 65 - Unhook the side
VEGA - SIRE 3 PLUS - DOGE 3 PLUS - SFERA 3 - SFERA 3 PLUS - PRINCE 3 - PRINCE 3 PLUS - GLOBE - TREND - ELISE 3 PLUS
EN
ELISE 3 PLUS: remove the screw and bracket from the side (see Fig. 66 page 35 ). Unhook the side (see Fig. 67 page 35 ).
Fig. 66 - Remove the screw and bracket Fig. 67 - Remove the side
• Clean the 2 pipes inside the combustion chamber (placed on the top) with a pipe cleaner (see Fig. 68 page
35 , Fig. 70 page 35 and Fig. 69 page 35 ).
• Loosen the two screws from the galvanised panel closing the flue gas compartment, which is found on both sides of the stove (see Fig. 71 page 35 ).
• Clean with a pipe cleaner and suction any ash accumulated inside (see Fig. 72 page 35 and Fig. 73 page
35 ).
• After the cleaning the opposite operation is to repeat checking the gasket efficiency and integrity: if necessary provide for its replacement by an Authorized Technician.
Fig. 68 - Fume passages Fig. 69 - Cleaning with a brush 1 Fig. 70 - Clean both the ducts
Fig. 71 - Fume chamber Fig. 72 - Cleaning with a brush 2 Fig. 73 - Fume chamber cleaning
14.5
FUME CONDUIT CLEANING
The exhaust system must be cleaned every season (or every 1500 operation hours).
VEGA - SIRE 3 PLUS - DOGE 3 PLUS - SFERA 3 - SFERA 3 PLUS - PRINCE 3 - PRINCE 3 PLUS - GLOBE - TREND - ELISE 3 PLUS 35
EN
Fig. 74 - Fume conduit cleaning Fig. 75 - Fume conduit (Sfera 3 Plus, Sfera 3 , Globe, Elise 3 Plus)
• Remove the side panel as described in FUME CHAMBER AND FUME PASSAGES CLEANING page 33 .
• Remove the inspection lid of the T-union (see Fig. 74 page 36 and Fig. 75 page 36 ).
• Extract the ash which has accumulated in the inner.
• After the cleaning repeate the opposite operation checking the integrity and eficiency of the gasket: if necessary have it replaced by an Autorized Technician.
It is important to sealed the cap othrwise noxiuous fumes will propagate among the room.
14.6
FUME FAN CLEANING
Clean every the year the fume fan from ash or dust which can cause a blade unbalance and a greater noise.
Fig. 76 - Fume fan cleaning: phase1 Fig. 77 - Phase 2 Fig. 78 - Phase 3
• Follow the process as describer in Fig. 76 page 36 , Fig. 77 page 36 and Fig. 78 page 36 .
14.7
ROOM FAN CLEANING
Clean every the year the room fan from ash or dust which can cause a blade unbalance and a greater noise.
36 VEGA - SIRE 3 PLUS - DOGE 3 PLUS - SFERA 3 - SFERA 3 PLUS - PRINCE 3 - PRINCE 3 PLUS - GLOBE - TREND - ELISE 3 PLUS
EN
Fig. 79 - Room fan cleaning
• Remove the sides (see FUME CHAMBER AND FUME PASSAGES CLEANING page 33 ).
• Remove dust build-up using a brush or a vacuum cleaner (see Fig. 79 page 37 ).
14.8
FUME PIPES ANNUAL CLEANING
Clean once a week from soot with brushes.
The cleaning operation must be executed by a specialized stove-repairer who will provide for the cleaning of fume pipe, chimney flue and chimney pot. He will also check their eficiency and will release a written declaration of the safety of the appliance. This operation must be executed at least once a year.
14.9
GENERAL CLEANING
For cleaning external and inner parts of the stove do not use steel wools, muriatic acid or other corrosive and abrasive materials.
14.10
CLEANING OF PAINTED METAL PANELS
To clean painted metal panels use a soft cloth. Do not use degreasant agents like alcool, diluents, acetone, gasoline because these could irremediably damage the varnish.
14.11
CLEANING OF CERAMIC AND STONE PANELS
Some stove models has an external lining made up of ceramic or stone. These pieces are handmade therefore they could inevitably present crazings, seedinesses, shadings.
To clean ceramic or stone panels use a soft and dry cloth. If using any cleaners this will seep through the crazings putting them in evidence.
14.12
GASKET REPLACEMENT
In case of deterioration of fire door, hopper or fume chamber gaskets, it is necessary to replace them by an autorized technician in order to guarantee the good running of the stove.
Use exclusively original spare parts.
14.13
GLASS CLEANING
The glass-ceramic of the fire door is able to stand till 700°C but not to thermal shocks.
VEGA - SIRE 3 PLUS - DOGE 3 PLUS - SFERA 3 - SFERA 3 PLUS - PRINCE 3 - PRINCE 3 PLUS - GLOBE - TREND - ELISE 3 PLUS 37
EN
The probable cleaning with usual sale product for glass cleaning must be effected at cool glass in order to avoid explosions.
You should clean the fire door glass every day!
15
IN CASE OF ANOMALY
15.1
ALARMS
Before of every testing and/or intervention by the Authorized Technician, the Authorized
Technician must check that the parameters of the mother board correspond to those of the table you own.
In case of doubts regarding the stove running, please allways contact the Authorized
Technician in order to avoid irreparable damages.
INTERVENTION ALARM
AL 1 - BLACK
OUT
CAUSE SOLUTION
Black out during ignition step
Clean the fire pot and start the stove up again.
AL 2 - EXHAUST
PROBE
Disconnected fume probe
Have the stove checked.
Faulty fume temperature probe
Replace the fume probe.
Faulty fume probe Replace the fume probe.
Faulty mother board Replace the mother board.
AL 3 - HOT
EXHAUST
AL 4 - FAN
FAILURE
The ambient exchanger fan does not work
Replace the ambient fan.
Pellet loading value too high "stage 5"
Adjust pellet loading
Fume extractor out of order
The pellet can burn also thank to chimney flue depression without the aid of the extractor. Have the fume extractor immediately replaced. It can be harmful to health to run the stove without extractor.
38 VEGA - SIRE 3 PLUS - DOGE 3 PLUS - SFERA 3 - SFERA 3 PLUS - PRINCE 3 - PRINCE 3 PLUS - GLOBE - TREND - ELISE 3 PLUS
ALARM CAUSE
Empty hopper
SOLUTION
Full the hopper.
The burning pot has not been cleaned
Clean the burning pot.
It has not reached the ignition threshold to the probe
Clean the burning pot and start the stove up again.
(If the problem persists please contact an Authorized
Technician).
Faulty ignition plug
AL 5 - FAILED
IGNITION
Too severe external temperature
Replace the igniter resistance.
Start the stove up again,
Humid pellet Assure you that the pellets are stored in a dry place.
EN
INTERVENTION
Blocked thermal probe Replace the thermal probe.
Faulty mother board Replace the mother board.
AL 6 - NO
PELLET
Empty hopper Fill the hopper.
Boiler overtemperature
Let the stove cooling. (If the problem persists please contact an Authorized Technician).
AL 7 - THERMAL
SAFETY
The ambient exchanger fan does not work
Replace the ambient fan.
Temporary blackout
The lack of tension during running implies boiler overheating and automatic thermostat intervention.
Leave it cooling, reset and start the stove up again.
Faulty automatic thermostat
Replace the automatic thermostat.
Faulty mother board Replace the mother board.
VEGA - SIRE 3 PLUS - DOGE 3 PLUS - SFERA 3 - SFERA 3 PLUS - PRINCE 3 - PRINCE 3 PLUS - GLOBE - TREND - ELISE 3 PLUS 39
EN
ALARM CAUSE
Obstructed exhaust
Faulty exhaust fan
Obstructed outlet connector
AL 8 - FAILURE
DEPRESS
Faulty pressostat
SOLUTION
The exhaust chimney is partially or tatally obstructed.
Please contact a Specialized Stove-repairer who checks the stove exhaust up to the chimney pot. Please have it immediately cleaned. It can be harmful to health to run the stove with the obstructed chimney.
INTERVENTION
The pellets can burn also thank to chimney flue depression without the aid of the exhaust fan. Have the exhaust fan immediately replaced. It can be harmful to health to run the stove without exhaust fan.
Clean the outlet connector.
Clean the pressostat.
Faulty mother board Replace the mother board.
AL 9 - DOOR
OPEN
Extreme chimney lenght
Contact a Specialized Stove-repairer and check that the exhaust chimney is in accordance with the regulations: see CHIMNEY FLUE page 6 .
Adverse weather conditions
The fire door is not correctly closed
Fire door microswitch faulty or out of order
In case of strong wind there can be a negative pressure to the chimney. Check it and start the stove up again.
Close the fire door correctly and check if the gaskets are damaged. (In this case have it replaced by an
Authorized Technician).
Replace the fire door microswitch.
15.2
PROBLEM SOLVING
Before of every testing and/or intervention of the Authorized Technician, the Autorized
Technician personally has the duty to verify that the parameters of the electronic board meet those of the reference table you own.
In case of doubts regarding the running of the stove please contact ONLY the Autorized
Technician in order to avoid irreparable damages!
40 VEGA - SIRE 3 PLUS - DOGE 3 PLUS - SFERA 3 - SFERA 3 PLUS - PRINCE 3 - PRINCE 3 PLUS - GLOBE - TREND - ELISE 3 PLUS
PROBLEM CAUSE
Stove without power supply
Control display does not ignite
Faulty control display
SOLUTION
Check if the plug is put in the socket.
Burned board protection fuse
Replace the board protection fuse (4A-250V).
Replace the control display.
Faulty flat cable Replace tha flat cable.
Faulty mother board
Replace the mother board.
Pellet does not reach the combustion chamber
Empty hopper Fill the hopper.
Auger blocked by a foreign object
(for example nails)
Clean the auger.
Auger motorreducer out of order
Replace the motorreducer.
Check on the display if there is an active alarm
"ACTIVE ALARM"
Have the stove overhauled.
Empty hopper Fill the hopper.
Auger blocked by a foreign object
(for example nails)
Clean the auger.
Fire extinguishes and stove stalls
Poor quality pellet Try with other pellet types.
Pellet loading value too law
"phase 1"
Check if there is an active alarm
"ACTIVE ALARM"
Running stove and display showing
"BURN POT CLEAN"
Automatic burning pot cleaning
Adjust pellet load.
Have the stove overhauled.
At idling stove and at maximum fume suction NO PROBLEM!
EN
TECHNICIAN
INTERVENTION
VEGA - SIRE 3 PLUS - DOGE 3 PLUS - SFERA 3 - SFERA 3 PLUS - PRINCE 3 - PRINCE 3 PLUS - GLOBE - TREND - ELISE 3 PLUS 41
EN
PROBLEM CAUSE SOLUTION
Insufficient combustion air
Check the following inscription: probable obstructions for combustion air inlet from the stove back or bottom; obstructed holes of the burning pot grid and/or burning pot with too ash. Have the fun blades and its screw cleaned.
Flames are weak and orange, pellet does not burn properly and the glass blackens
Obstructed exhaust
The exhaust chimney is partly or fully obstructed. Contact an expert stove-repairer to check the exhaust up to the chimney pot. Please clean it immediately.
Obstructed stove Clean the stove inner.
TECHNICIAN
INTERVENTION
Exhaust fan out of order
Pellet can burn also thank to chimney flue depression without exhaust fan. Have the exhaust fan replaced immediately.
It can be harmful to health to run the stove without fume exhaust fan.
Faulty fume temperature probe
Replace the fume probe.
Heat exchanger fan keeps turning even when the stove has cooled Faulty mother board
Replace the mother board.
Faulty or broken door gaskets
Replace the gaskets.
Ash nearby the stove
Fume pipes not sealed
Contact an Autorized Stove-repairer who will seal the gaskets with silicone at high temperature and/or will replace the pipes with others in compliance with current regulations.
A not sealed fume outlet can cause damages to health.
Stove running and display showing
"WORK, MODULAT"
Room temperature reached
Stove running and display showing
"HOT EXHAUST"
Fume outlet limit temperature reached
Stove running and display showing
"SERVICE"
Routine maintenance alert (it does not block the system)
Stove idling. NO PROBLEM!
Stove idling. NO PROBLEM!
When this flashing message appears upon start-up, it means that the preset operating hours have elapsed before maintenance. Contact the service centre.
42 VEGA - SIRE 3 PLUS - DOGE 3 PLUS - SFERA 3 - SFERA 3 PLUS - PRINCE 3 - PRINCE 3 PLUS - GLOBE - TREND - ELISE 3 PLUS
EN
16
TECHNICAL DATAS
16.1
REPAIR INFORMATION
Now we give some instructions for the Authorized Technician to take into consideration to have access to stove mechanical components.
• For fuse replacement in the electric socket which stands on the back of the stove, extract the fuses to change with the aid of a screwdriver for opening the shutter (see Fig. 80 page 43 ).
Fig. 80 - Shutter with fuses to remove Fig. 81 - Rear panel removal
Proceed as follows:
• Remove the rear panel (see Fig. 81 page 43 ).
• After these operations you can have access at the following components: geared motor, ignition plug, ambient fan, fume fan, ambient probe, fume probe, thermostat, electronic board, pressostat.
• For cleaning or replacemente of the auger it is necessary to unscrew the three bolt of the geared motor and to extract it, unscrew the two screws lying under the geared motor of the auger, remove the hand rejector inside the hopper and then unscrew the inner bolt of the auger.
• To assembly proceed at the contrary.
VEGA - SIRE 3 PLUS - DOGE 3 PLUS - SFERA 3 - SFERA 3 PLUS - PRINCE 3 - PRINCE 3 PLUS - GLOBE - TREND - ELISE 3 PLUS 43
EN
16.2
FEATURES
DESCRIPTION
WIDTH
DEPTH
SFERA 3 9,5 kW
53,6 cm
57 cm
HEIGHT
WEIGHT
104 cm
98 - 108 kg
INTRODUCED THERMIC POWER (Min/Max) 3 - 10,7 kW
NOMINAL THERMIC POWER (Min/Max) 2,8 - 9,5 kW
93 - 86,5 %
85 - 221 °C
EFICIENCY (Min/Max)
FUME TEMPERATURE (Min/Max)
FUME MAXIMUM LOADING CAPACITY
(Min/Max)
CO EMISSIONS (13% O
2
) (Min/Max)
OGC EMISSIONS (13% O
2
) (Min/Max)
NO
X
EMISSIONS (13% O
2
) (Min/Max)
Medium CO CONTENTS at 13% O
(Min/Max)
2
Medium POWDER CONTENTS at 13% O
(Max)
2
CHIMNEY DEPRESSION (Max)
3,1 - 6,8 g/s
0,030 - 0,005 %
2 - 1 mg/Nm
12 mg/Nm
11 Pa
3
3
117 - 152 mg/Nm
375 - 67 mg/Nm 3
3
MINIMUM SAFETY DISTANCE from flammable materials
ON SHARED CHIMNEY FLUE
FUME OUTLET DIAMETER
COMBUSTIBLE
PELLETS HEATING VALUE
PELLETS HUMIDITY
HEATING VOLUME 18/20°C Coeff.
0,045 kW (Min/Max)
HOURLY CONSUMPTION (Min/Max)
HOPPER CAPACITY
RANGE (Min/Max)
SUPPLY
POWER INPUT (Max)
INGNITER RESISTANCE POWER INPUT
MINIMUM EXTERNAL AIR INLET (last effective area)
STOVE WITH SEALED CHAMBER
EXTERNAL AIR INLET FOR SEALED
CHAMBER
300 mm
NO
Ø80 mm
Pellet Ø6-7 mm
5 kWh/kg
≤ 10%
67 - 228 m
0,6 - 2,3 kg/h
22 kg
9,6 - 36,7 h
230 V - 50 Hz
360 kW
300 W
80 cm
YES
60 mm
2
3
12 mg/Nm 3
11 Pa
300 mm
NO
Ø80 mm
Pellet Ø6-7 mm
5 kWh/kg
≤ 10%
67 - 252 m 3
0,6 - 2,4 kg/h
22 kg
9,2 - 36,7 h
230 V - 50 Hz
360 kW
300 W
80 cm 2
YES
60 mm
GLOBE 10,5 kW
53,6 cm
57 cm
104 cm
98 kg
3 - 11,9 kW
2,8 - 10,5 kW
93 - 87,1 %
85 - 228 °C
3,1 - 6,5 g/s
0,030 - 0,007 %
2 - 1 mg/Nm 3
117 - 136 mg/Nm 3
375 - 83 mg/Nm 3
12 mg/Nm 3
11 Pa
300 mm
NO
Ø80 mm
Pellet Ø6-7 mm
5 kWh/kg
≤ 10%
67 - 252 m 3
0,6 - 2,4 kg/h
22 kg
9,2 - 36,7 h
230 V - 50 Hz
360 kW
300 W
80 cm 2
YES
60 mm
SFERA 3 PLUS 10,5 kW
53,6 cm
57 cm
104 cm
98 - 108 kg
3 - 11,9 kW
2,8 - 10,5 kW
93 - 87,1 %
85 - 228 °C
3,1 - 6,5 g/s
0,030 - 0,007 %
2 - 1 mg/Nm 3
117 - 136 mg/Nm 3
375 - 83 mg/Nm 3
44 VEGA - SIRE 3 PLUS - DOGE 3 PLUS - SFERA 3 - SFERA 3 PLUS - PRINCE 3 - PRINCE 3 PLUS - GLOBE - TREND - ELISE 3 PLUS
DESCRIPTION
WIDTH
DEPTH
HEIGHT
SIRE 3 PLUS 10,5 kW
54,4 cm
52,3 cm
104,8 cm
WEIGHT 131 kg
INTRODUCED THERMIC POWER (Min/Max) 3 - 11,9 kW
NOMINAL THERMIC POWER (Min/Max) 2,8 - 10,5 kW
EFICIENCY (Min/Max) 93 - 87,1 %
FUME TEMPERATURE (Min/Max)
FUME MAXIMUM LOADING CAPACITY
(Min/Max)
85 - 228 °C
3,1 - 6,5 g/s
CO EMISSIONS (13% O
2
) (Min/Max)
OGC EMISSIONS (13% O
2
) (Min/Max)
NO
X
EMISSIONS (13% O
2
) (Min/Max)
Medium CO CONTENTS at 13% O
2
(Min/Max)
Medium POWDER CONTENTS at 13% O
(Max)
2
CHIMNEY DEPRESSION (Max)
MINIMUM SAFETY DISTANCE from flammable materials
0,030 - 0,007 %
2 - 1 mg/Nm 3
117 - 136 mg/Nm 3
375 - 83 mg/Nm
12 mg/Nm
11 Pa
300 mm
3
3
NO
Ø80 mm
Pellet Ø6-7 mm
5 kWh/kg
≤ 10%
ON SHARED CHIMNEY FLUE
FUME OUTLET DIAMETER
COMBUSTIBLE
PELLETS HEATING VALUE
PELLETS HUMIDITY
HEATING VOLUME 18/20°C Coeff.
0,045 kW (Min/Max)
HOURLY CONSUMPTION (Min/Max)
HOPPER CAPACITY
RANGE (Min/Max)
SUPPLY
POWER INPUT (Max)
INGNITER RESISTANCE POWER INPUT
MINIMUM EXTERNAL AIR INLET (last effective area)
STOVE WITH SEALED CHAMBER
EXTERNAL AIR INLET FOR SEALED
CHAMBER
67 - 252 m
0,6 - 2,4 kg/h
22 kg
9,2 - 36,7 h
230 V - 50 Hz
360 kW
300 W
80 cm
YES
60 mm
2
3
12 mg/Nm 3
11 Pa
300 mm
NO
Ø80 mm
Pellet Ø6-7 mm
5 kWh/kg
≤ 10%
67 - 252 m 3
0,6 - 2,4 kg/h
22 kg
9,2 - 36,7 h
230 V - 50 Hz
360 kW
300 W
80 cm 2
YES
60 mm
DOGE 3 PLUS 10,5 kW
55,4 cm
54 cm
105,6 cm
118 kg
3 - 11,9 kW
2,8 - 10,5 kW
93 - 87,1 %
85 - 228 °C
3,1 - 6,5 g/s
0,030 - 0,007 %
2 - 1 mg/Nm 3
117 - 136 mg/Nm 3
375 - 83 mg/Nm 3
12 mg/Nm 3
11 Pa
300 mm
NO
Ø80 mm
Pellet Ø6-7 mm
5 kWh/kg
≤ 10%
67 - 252 m 3
0,6 - 2,4 kg/h
22 kg
9,2 - 36,7 h
230 V - 50 Hz
360 kW
300 W
80 cm 2
YES
60 mm
ELISE 3 PLUS 10,5 kW
65 cm
60,3 cm
108 cm
138 kg
3 - 11,9 kW
2,8 - 10,5 kW
93 - 87,1 %
85 - 228 °C
3,1 - 6,5 g/s
0,030 - 0,007 %
2 - 1 mg/Nm 3
117 - 136 mg/Nm 3
375 - 83 mg/Nm 3
EN
VEGA - SIRE 3 PLUS - DOGE 3 PLUS - SFERA 3 - SFERA 3 PLUS - PRINCE 3 - PRINCE 3 PLUS - GLOBE - TREND - ELISE 3 PLUS 45
EN
DESCRIPTION
WIDTH
DEPTH
HEIGHT
WEIGHT 104 kg
INTRODUCED THERMIC POWER (Min/Max) 3 - 11,9 kW
NOMINAL THERMIC POWER (Min/Max) 2,8 - 10,5 kW
EFICIENCY (Min/Max) 93 - 87,1 %
FUME TEMPERATURE (Min/Max) 85 - 228 °C
FUME MAXIMUM LOADING CAPACITY
(Min/Max)
CO EMISSIONS (13% O
2
) (Min/Max)
OGC EMISSIONS (13% O
2
) (Min/Max)
NO
X
EMISSIONS (13% O
2
) (Min/Max)
Medium CO CONTENTS at 13% O
(Min/Max)
2
Medium POWDER CONTENTS at 13% O
(Max)
2
VEGA 10,5 kW
54 cm
54 cm
105 cm
3,1 - 6,5 g/s
0,030 - 0,007 %
375 - 83 mg/Nm
12 mg/Nm 3
3
TREND 10,5 kW
54 cm
54 cm
105 cm
104 kg
3 - 11,9 kW
2,8 - 10,5 kW
93 - 87,1 %
85 - 228 °C
3,1 - 6,5 g/s
0,030 - 0,007 %
375 - 83 mg/Nm
12 mg/Nm 3
3
PRINCE
53,6 cm
54 cm
104,5 kg
3
105,8 cm
10,5 kW
3 - 11,9 kW
2,8 - 10,5 kW
93 - 86,5 %
85 - 221 °C
3,1 - 7,0 g/s
0,030 - 0,006 %
PRINCE 3 kW
PLUS 10,5
53,6 cm
54 cm
105,8 cm
105,5 kg
3 - 11,9 kW
2,8 - 10,5 kW
93 - 87,1 %
85 - 228 °C
3,1 - 6,5 g/s
0,030 - 0,007 %
2 - 1 mg/Nm 3 2 - 1 mg/Nm 3 2 - 1 mg/Nm 3 2 - 1 mg/Nm 3
117 - 136 mg/Nm 3 117 - 136 mg/Nm 3 117 - 147 mg/Nm 3 117 - 136 mg/Nm 3
375 - 77 mg/Nm
11 mg/Nm 3
3 375 - 83 mg/Nm
12 mg/Nm 3
3
CHIMNEY DEPRESSION (Max)
MINIMUM SAFETY DISTANCE from flammable materials
ON SHARED CHIMNEY FLUE
11 Pa
300 mm
11 Pa
300 mm
11 Pa
300 mm
11 Pa
300 mm
FUME OUTLET DIAMETER
COMBUSTIBLE
PELLETS HEATING VALUE
PELLETS HUMIDITY
HEATING VOLUME 18/20°C Coeff.
0,045 kW (Min/Max)
HOURLY CONSUMPTION (Min/Max)
NO
Ø80 mm
Pellet Ø6-7 mm
5 kWh/kg
≤ 10%
67 - 252 m 3
NO
Ø80 mm
Pellet Ø6-7 mm
5 kWh/kg
≤ 10%
67 - 252 m 3
NO
Ø80 mm
Pellet Ø6-7 mm
5 kWh/kg
≤ 10%
67 - 252 m 3
NO
Ø80 mm
Pellet Ø6-7 mm
5 kWh/kg
≤ 10%
67 - 252 m 3
HOPPER CAPACITY
RANGE (Min/Max)
SUPPLY
POWER INPUT (Max)
INGNITER RESISTANCE POWER INPUT
MINIMUM EXTERNAL AIR INLET (last effective area)
STOVE WITH SEALED CHAMBER
EXTERNAL AIR INLET FOR SEALED
CHAMBER
0,6 - 2,4 kg/h
22 kg
9,2 - 36,7 h
230 V - 50 Hz
360 kW
300 W
80 cm
YES
60 mm
2
0,6 - 2,4 kg/h
22 kg
9,2 - 36,7 h
230 V - 50 Hz
360 kW
300 W
80 cm
YES
60 mm
2
0,6 - 2,5 kg/h
22 kg
8,8 - 36,7 h
230 V - 50 Hz
360 kW
300 W
80 cm
YES
60 mm
2
0,6 - 2,4 kg/h
22 kg
9,2 - 36,7 h
230 V - 50 Hz
360 kW
300 W
80 cm
YES
60 mm
2
46 VEGA - SIRE 3 PLUS - DOGE 3 PLUS - SFERA 3 - SFERA 3 PLUS - PRINCE 3 - PRINCE 3 PLUS - GLOBE - TREND - ELISE 3 PLUS
NOTE
pellet stoves
· wood thermostoves stoves
· pellet wood cooking fireplace inserts stoves
CADEL srl
FREEPOINT by Cadel
Via Foresto Sud, 7
31025 Santa Lucia di Piave (TV) - ITALY tel. +39.0438.738669
fax +39.0438.73343
www.cadelsrl.com
Partner of:
Rev.01 - 2015
Download
Advertisement