Cooper Lighting METALUX 496T8 Specification


Add to my manuals
2 Pages

advertisement

Cooper Lighting METALUX 496T8 Specification | Manualzz

COOPER LIGHTING - METALUX

®

DESCRIPTION

The EIM Series is an energy efficient family of industrials that feature premium performance and durability. The industrial series incorporates heavy duty, embossed, reflectors that precisely direct and effectively control light. The EIM reflector is a unique design that was developed to prevent debris accumulation in special applications. The versatile EIM Series can be installed using various mounting methods and numerous options and accessories are available.

The EIM Series can be utilized in simple task and area lighting to the most demanding specialized industrial applications with environmental requirements.

Catalog #

Project

Comments

Prepared by

Type

Date

SPECIFICATION FEATURES

A ... Construction

Channel is code gauge prime cold rolled steel. Die formed with deep

V-grooves for tong hanger. Die formed channel connector assures straight rows and continuity of ground through set screws.

Lampholder mounting brackets are easily inserted with snap-in action.

B ... Electrical*

Ballast are CBM/ETL Class "P" and positively secured by mounting bolts. Metal clad lampholders are spring loaded for turret safety.

UL/CUL listed. Suitable for damp locations.

C ... Finish

Multistage iron phosphate pretreatment ensures maximum bonding and rust inhibitor.

Lighting grade, baked white enamel finish.

A B C

D

D ... Reflectors

Painted after fabrication. Die formed code gauge steel. Deep draw full width ribs formed with one press stroke. Side flanges lend strength with downward turn.

Reflector design prevents lint, dust and debris buildup. Easily cleaned.

Baked white enamel 13" width.

Four foot sections. Reflectors secured by positive retaining screw. Reflector aligners provided.

Standard with 20% uplight (EIM).

Closed top reflector (ECIM).

Optional Industrial fixtures are available incorporating silver technology enhancements.

(SilverLining)

EIM

396

396T8

496

496T8

6-3/8"

[162mm]

8' INDUSTRIAL

3 OR 4 LAMP

SLIMLINE

Environmental Heavy Duty

Industrial

13"

[330mm]

LAMP CONFIGURATIONS

X

6-3/8"

[162mm]

X=4-1/4"

[108mm]

Y=3"

[76mm]

Y Y

13" [330mm]

X

6-3/8"

[162mm]

X=4-1/4"

[108mm]

Y=2"

[51mm]

Y Y Y

13" [330mm]

MOUNTING DATA

5/16"

[8mm]

4-1/4"

[108mm]

11/16" [17mm] x 1 K.O. (2)

7/8" [22mm] K.O. (5)

7/32" [6mm] x 3/8" [10mm] K.O. (4)

Ground Screw Bump

76" [1930mm]

85-1/4" [2165mm]

89-1/2" [2273mm]

96" [2438mm]

1-1/16"

[27mm]

Specifications and Dimensions subject to change without notice.

Consult your representative for additional options and finishes.

E N E R G Y D ATA

Input Watts:

EB Ballast & STD Lamps

396 (221)

396T8 (180)

496 (272)

496T8 (220)

ES Ballast & STD Lamps

496 (316)

STD Ballast & STD Lamps

396 (270)

496 (360)

Luminaire Efficacy Rating

LER = FI-87

Catalog Number: EIM-396T8

Yearly Cost of 1000 lumens,

3000 hrs at .08 KWH = $2.76

*Reference the lamp/ballast data in the

Technical Section for specific lamp/ballast requirements.

LAMPS CONTAIN MERCURY. DISPOSE ACCORDING

TO LOCAL, STATE OR FEDERAL LAWS

Safe and convenient means of

disconnecting power

ADF020742

09/17/2008 4:23:56 PM

PHOTOMETRICS

||

EIM-396T8

Energy Saving

Ballast

F96T8/SPX35 Lamps

5950 Lumens

Spacing criterion:

(II) 1.3 x mounting height, ( ) 1.4 x mounting height

Efficiency 92.8%

Test Report:

EIM396T8.IES

LER = FI-87

Yearly Cost of 1000 lumens, 3000 hrs at

.08 KWH = $2.76

C o e f f i c i e n t s o f U t i l i z a t i o n

8

9

10

6

7

4

5 rc rw

RCR

2

3

0

1

Effective floor cavity reflectance

80% 70%

70 50 30 10 70 50 30 10

107 107 107 107

98 93 89 85

88 80 74 69

80 70 62 56

73 62 54 47

67 55 46 40

62 49 41 35

57 44 36 30

53 40 32 27

49 37 29 24

46 34 26 22

103 103 103 103

94 90 86 83

85 78 72 67

77 68 61 55

70 60 52 46

64 53 45 39

59 48 40 34

55 43 35 30

51 39 32 26

47 36 29 24

44 33 26 21

Z o n a l L u m e n S u m m a r y

Zone

0-30

0-40

0-60

0-90

90-180

0-180

Lumens

3425

5752

10795

14235

2324

16559

%Lamp

19.2

32.2

60.5

79.7

13.0

92.8

%Fixture

20.7

34.7

65.2

86.0

14.0

100.0

ORDERING INFORMATION

20%

50%

50 30 10

96 96 96

83 80 78

72 67 63

63 57 52

56 49 44

50 43 38

45 38 33

40 34 29

37 30 25

34 27 23

31 25 21

S A M P L E N U M B E R : E I M - 3 9 6 T 8 - 1 2 0 V- E B 8 1- U

30%

50 30 10

89 89 89

77 75 73

67 63 60

59 54 50

52 47 42

46 41 36

42 36 31

38 32 28

35 29 25

32 26 22

29 24 20

10%

50 30 10

83 83 83

72 70 69

63 59 57

55 51 47

49 44 40

43 39 35

39 34 30

36 30 27

33 27 24

30 25 21

28 23 19

0%

0

45

38

32

28

80

66

54

25

22

19

17

EIM

C a n d e l a

2014

1273

525

17

87

255

443

621

Along II

4237

4182

3980

3670

3233

2680

768

892

974

1019

1031

70

80

90

100

110

120

130

140

150

160

170

180

Angle

0

10

20

30

40

50

60 2472

1687

515

63

139

334

130

323

45 o

4237

4186

4088

3845

3553

3172

560

655

861

988

1031

2485

1589

377

62

102

374

338

179

Across

4237

4263

4189

4014

3832

3280

386

635

736

981

1031

Tandem

Blank =4'

Length

8T =8' Length

Series

EIM =

Apertured

Reflector

ECIM =Closed

Top

Reflector

Lamp Spacing

Blank =Standard Spacing

N =Narrow Spacing for 2

Lamp Only (10% uplight)

Silver (3)

Reflector

SS =

Silver-

Lining

Reflector

Number of Lamps

3 or 4 Lamps

(Not included)

Wattage (Length)

96 =60/75W T12 (72") SL

96T8 =59W T8 (96") SL

Voltage (1)

120V =120 Volt

277V =277 Volt

347V =347 Volt

UNV =Universal Voltage 120-277 (2)

Options

GL =Single Element Fuse

GM =Double Element Fuse

Emergency =EM Installed

Ballast Type (1)

EB8 =T8 Electronic Instant Start.

Total Harmonic Distortion < 10%

No. of Ballast

1, 2 or 3

EB8 /PLUS =T8 Electronic Instant Start.

High Ballast Factor >1.13. Total

No. of

Ballast

1, 2 or 3

Harmonic Distortion < 20%

ER8 =T8 Electronic Program Rapid Start.

Total Harmonic Distortion < 10%

No. of Ballast

1, 2 or 3

EB2 =T12 Electronic Rapid Start.

No. of Ballast

1 or 2

DLS =Digital Lighting System Dimming

Options

RIF1 =Radio Interference

Suppressor

6-3/18 SJT-C&P-515P =Cord

& Plug (120V)

6-3/18 SJT-C&P-

L715P =Cord & Plug (277V)

PI/CPI =Plug-In Option

TILW

POX

=Tandem In-Line

Wiring Option (Consult

TILW Option Catalog Page)

=Porlux Finish

(See options & accessories)

Packaging

U =Unit Pack

4B =4 Bulk

NOTES:

(1) markets.

Products also available in non-US voltages and frequencies for international

(2)

Not available when specifying emergencies, voltage must be specific.

(3)

Silver lining not available on fixtures with HO, VHO or PG.

Specifications & dimensions subject to change without notice. Consult your Cooper

Lighting Representative for availability and ordering information.

ACCESSORIES (Order Separately)

SHIPPING INFORMATION

Catalog No.

EIM-396T8

1

EIM-496T8

Wt.

36 lbs.

36 lbs.

A1B/Spacer-U=Spacer 1-1/2" to 2-1/2" from ceiling

(Use 2 per fixture)

ATG-4=Tong Hanger (Use 2 per fixture)

SCF=Fixed Stem Set (Specify Length)

SCS=Swivel Stem Set (Specify Length)

SCA=Adjustable 48" Stem Set

AYC-Chain/Set-U=Chain Hanger Set (Use 1 set per fixture)

WG/DI-4FT-U 1 =Wire Guard

WGG/DI-4FT-U=Wire Gym Guard

DI2=Long Connector

CEP=Closed End Plate

(Note: Reflector will extend 1/4" past the end plate).

(Additional Accessories Available. See Options and Accessories Section).

Specifications and Dimensions subject to change without notice.

Metalux • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801