Hanse MicroScope HVS-CM500PC User Manual
Advertentie
Advertentie
HVS-CM500PC(USB)
User s guide
Reg. No. 249826 for Micro scope & Reg. No. 0246851 for multifunctional zoom camera as a practical new device field in Korean
Intellectual Property Office
Thank you for purchasing Hanse Microscope
Warning : Please read this user s guide prior to use.
Never use this product for observing your or other people s eyes as LED light cause eye s injury.
1. Contents
1. Contents
2. Caution
3. Main features
4. Application
5. Composition
6. Name of each part
7. How to use the mirror for ear observation
8. Applicable system network
9. Specifications
10. Install of Hardware
11. Install Program
12. Warranty
9
12
7
8
23
6
7
5
6
2
3
4
2
MicroScope User s guide
2.
Caution
This user s guide show you exactly the features and specifications of Hanse Microscope HVS-CM500PC(USB).
For safe and right use please read this user s guide and relevant cautions before using or installation.
Please keep this user s guide where you can get it easily whenever you need.
Please treat lens carefully like your eye to avoid any dust or fingerprint on it and use soft fabric or something similar when you cleaning the lens.
To keep from damaging your HVS-CM500PC(USB) avoid exposing it to moisture and extreme temperatures.
Do not use or store your HVS-CM500PC(USB) where strong electrostatic or electrical noise may be generated.
Do not drop or give excessive shock to the HVS-
CM500PC(USB).
Do not disassemble or touch the inside of the
HVS-CM500PC(USB).
This may result in malfunctions of the microscope.
Do not use organic solvents, such as thinner or benzene, on to the HVS-CM500PC(USB).
MicroScope User s guide
3
3.
Main features
This product is a multi-functional zoom camera available to various application that s more convenient to use than others with the following excellent features.
USB 1.1 Compliant (USB Interface)
USB 1.1 compliant(USB interface)
1/3inch CMOS VGA(640X480)m CIF(320X240)
Portable with compact size
X20~X75 Magnification with 17 monitor (It depends on the distance of object)
LED for colse photography
Serveral images can be analysized, recorded and printed with S/W
Image capture by H/W & S/W
Beauty care, education tool, inspection for components and etx can be applied
4
MicroScope User s guide
4.
Application
Beauty cares
Observing skin and hair condition
Education tool in school
Electronic components inspection
Applicable to CCTV camera substitute
LED function is to be operated only for close distance photographing
MicroScope User s guide
5
5.
Composition
Body
Menual
Base
Cable
Mirror for ear observation
Extension cable : option
Microscope
CD
6.
Name of each part
Capture
Focus control lever
Transparent window
Lens
LED
6
MicroScope User s guide
7. How to use the mirror for ear observation
Take off transparent window from the body.
Assemble the mirror instead.
Never use this product for observing your or other people s eyes as LED light cause eye s injury.
8.
Applicable system network
Microscope
HVS-CM500PC
COMPUTER
MicroScope User s guide
7
9. Specifications
Description
Image Sensor
Device Type
Frame Rate
Interface
Signal/Noise Ratio
Pixel Resolution
Exposure Control
HVS-CM500PC
318,000 pixels (VGA 1/3” CMOS)
Digital Video Camera
Up to 30 frames
USB Specifcation 1.1
c.56dB
640 480(VGA), 320 240(CIF)
Automatic(to+82dB)
Gain Control
USB Cable
Automatic(to+24dB)
1.5m 0.2
Supply Voltage 4V1~6V0 DC(Internally regulated)Through USB
20~75, magnification
8
MicroScope User s guide
10. Install of Hardware
1. Install with P&P Process
1) Connect Microscope to USB port of your computer
2) Checking “Browse”
MicroScope User s guide
9
3) After checking drive position , click “OK”Button
4) After Click “Browse” for original copy position, pointing win98 holder of program CD
Press “confirm” buttion and all the drive installation is finished.
10
MicroScope User s guide
5) If the following picture displayed, click “OK” button
MicroScope User s guide
11
11. Install Program
1. Install Program
1) Installation.
Press the next button for installShield wizard.
12
Choose Agreement of License and Press the next button.
MicroScope User s guide
Fill user s name and company name out in user s information window and Press the next button.
Choose the installation type users want to and Press the next button.
It is recommended for users to choose Full set up basically.
MicroScope User s guide
13
Press the install button to set up the program.
Window is appeared for displaying installation.
14
MicroScope User s guide
The program will be updated on our homepage and to renew the updated program ,choose yes, check the renewed program and press the finish button.
After finishing renewing program, press the Finish button, then installation is completed successfully.
MicroScope User s guide
15
2) Note
In case microscope program was installed before, execute the existed set up program again.
Above the window, choose the Remove botton and press the Next button.
After remove the program completely, execute the new version of setup.exe and install program again.
16
MicroScope User s guide
2. Program Manual
1) Starting program
Connect to USB camera and start program pressing
Microscope_Beta icon (Start -> Program -> Hanse ->
Microscope_Beta)
Note
Don t start program without Microscope. If you do without connecting Microscope to PC, you ll see the below message.
In this case, start the program after connect Microscope to
PC,.
To see only capture screen without live screen, press enter button.
In case you connect camera to PC, the above warning message won t appear.
MicroScope User s guide
17
1
2
3
5
4
1 : Menu window
2 : Tool window
3 : Screen window
4 : Folder window
5 : Temp window
1-1) Menu window
Pointing Menu
When click File , pop up menu shows Open, Print, Print
Setup, Exit in a row.
The window is opened as below :
18
MicroScope User s guide
1. Driver window 2. Picture file window
Driver window It shows saving driver and folder.
Picture file window It shows chosen driver and picture file in folder.
Print : Open Print Setup Mode and Pre-view.
Print Setup : Open Print Setup mode which is set by default.
Exit : Exit the program
When click Image , pop up menu shows Snap Shot .
Snap Shot : Capture Live Image
MicroScope User s guide
19
When click View pop up menu shows Division 1,2,4 .
Division1 : Screen 1 (640*480)
Division2: Screen 2 (320*240)
Division4: Screen4 (320*240)
When click Setup , pop up menu shows Auto Increment
File Name
Auto Increment File Name : When save files,it determines whether to save one picture or automatically save with the increasing series number.
When click Help pop up menu shows About .
About : It is description of product (version, manufacturer, etc...)
1-2) Tool window
The functions of below Icons are the same to the menu.
: File Open
:Snap Shot
:Live/Capture
In case of 1 screen, you can choose the main screen between live or capture.
In case of 2 screens, you can choose the left side screen between live or capture.
In case of 4 screens, you can select one top and left side screen between live or capture.
20
MicroScope User s guide
:Division
You can select screen as one full screen, two screens and four screens.
: Setup
: Help
: Exit
You can put the head letter of title for screen that you want to record.
You can define the location of file that you want to capture.
1-3) Screen window
Screen 1 shows Live and Capture .
Screen 2 shows Capture only and screen 4 can be chosen between Live and Capture .
Screen2,3,4 shows Capture only and screen1 can be chosen between Live and Capture .
MicroScope User s guide
21
1-4) Folder window
This window shows picture file which would be now loaded.
When picture is captured, this windows shows the captured picture.
1-5) Temp window
When double-click the picture which was saved at folder, the picture is saved at Temp window.
When double-click the screen of Temp Window, the saved pictures are shown at screen window
In a row.
22
MicroScope User s guide
12. WARRANTY
How to get A/S
PRODUCT
MODEL
DATE OF PURCHASE
TERMS OF WARRANT
SALES AGENT
ADDRESS OF SALES
AGENT
Microscope
YEAR MONTH DATE
We will guarantee as follows :
1. This product is made through rigid quality control and test process
2. In case that this product is out of order due to the defect in manufacturing even through the product has been normally used, A/S will be afforded at free of charge for one year after purchasing date.
3. In case of the followings, Hanse will afford A/S with charge of cost even through warrant period.
1) Out of order by user's mishandling or move
2) In case of wrong repair or damage by modification of inner part
3) Out of order by natural disaster or disorder in power source
4) In case of omission, correction without confirmation, loss of warranty card.
4. Please be careful of keeping this warranty card as it won't be reissued.
5. Please surely present the warranty card in A/S request.
MicroScope User s guide
23
INFORMATION TO THE USER
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one more of the following measures:
-. Reorient or relocate the receiving antenna.
-. Increase the separation between the equipment and receiver.
-. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
-. Consult the dealer or an experienced radio/TV technician for help.
CAUTION
Any changes or modifications not expressly approved by the manufacturer could void the user’s authority to operate the equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to the
following
two
conditions:
(1) this device
may
not
cause
harmful interference, and
(2)
this
device
must
accept
any
interference
received,
including interference that may cause undesired operations.
Seoul Office :
2F, 260-7, Youmchang-Dong, Gangseo-Gu, Seoul 157-862, Korea
Tel: +82-2-6675-2500 Fax: +82-2-6675-2501 http://www.hanseelec.com E- mail:hanse hanseelec.co.kr
Factory :
4L, 33B, Namdong-Industrial Zone, 613-3,Namchon-Dong, Namdong-Gu, Incheon
405-846, Korea Tel: +82-32-816-8700 Fax: +82-32-818-4473
4
MicroScope User s guide
Downloaden
Advertentie