OWNER’S MANUAL
This file is part of WP 34S.
WP 34S is free software: you can redistribute it and / or modify it under the terms of the GNU General Public License as published by the
Free Software Foundation, either version 3 of the License, or (at your option) any later version.
WP 34S is distributed in the hope that it will be useful, but without any warranty; without even the implied warranty of merchantability or fitness for a particular purpose. See the GNU General Public License for more details.
You should have received a copy of the GNU General Public License along with WP 34S. If not, please see http://www.gnu.org/licenses/ .
First aid for those complaining about getting trapped in an unexpected or unwanted calculator mode while playing around before reading:
(i.e. ) will bring you back to floating point mode.
For those who don‘t even read this: Sorry, we can‘t help you.
WP 34S Owner‘s Manual
Edition 2.2 Page 1 of 103
TABLE OF CONTENTS
Welcome ..................................................................................................................... 4
Print Conventions ....................................................................................................... 6
Getting Started ........................................................................................................... 6
What‘s on the Keyboard and How to Access it? ......................................................... 7
Real and Integer Operations ..................................................................................... 14
Statistical Distributions, Probabilities etc. ................................................................. 15
Matrices .................................................................................................................... 16
Complex Operations ................................................................................................. 17
Memory ..................................................................................................................... 18
Stack Mechanics ...................................................................................................... 20
Comparing and Addressing Real Numbers .............................................................. 22
Comparing and Addressing Complex Numbers ........................................................ 23
Addressing Labels .................................................................................................... 24
Display and Modes ................................................................................................... 25
Fonts......................................................................................................................... 32
Index of Operations .................................................................................................. 33
A - C ..................................................................................................................................34
D - F ..................................................................................................................................37
G - I ...................................................................................................................................41
J - L ...................................................................................................................................43
M - O .................................................................................................................................46
P - R ..................................................................................................................................49
S - U ..................................................................................................................................54
V - Z ..................................................................................................................................58
-
..................................................................................................................................61
- the End ........................................................................................................................64
Alphanumeric input:...........................................................................................................67
Non-programmable Control, Clearing and Information Commands ...................................69
WP 34S Owner‘s Manual
Edition 2.2 Page 2 of 103
Catalogs ................................................................................................................... 71
Catalog Contents in Detail: ................................................................................................74
Addressing Catalog Items .................................................................................................77
Constants ..........................................................................................................................78
Unit Conversions ...............................................................................................................82
Predefined Global Alpha Labels ........................................................................................86
Messages ................................................................................................................. 86
Programmed Input and Output ................................................................................. 89
Interactive Programming ........................................................................................... 90
Interrupting a Program for Display of Information ..............................................................90
Temporary Displays ..........................................................................................................91
Data Input .........................................................................................................................91
Hotkeys .............................................................................................................................91
Keyboard Codes ...............................................................................................................92
Direct Keyboard Access ....................................................................................................93
Appendix A: Support for Flashing, Serial I/O etc. ..................................................... 94
How to Flash Your HP 20b or 30b .....................................................................................94
Commands for Handling Flash Memory on Your WP 34S .................................................95
Mapping of Memory Regions to Emulator State Files ........................................................96
Data Transfer Between Your WP 34S and Your PC (SAM-BA) .........................................96
Data Transfer Between Your WP 34S and Your PC (Serial I/O) ........................................97
More Keyboard Commands Employing ON .......................................................................98
Appendix B: More Routines and Commands ............................................................ 99
Library Routines ................................................................................................................99
Internal Commands (Use at Your Own Risk) .....................................................................99
Appendix C: Release Notes .................................................................................... 102
WP 34S Owner‘s Manual
Edition 2.2 Page 3 of 103
JUST IN CASE …
... you still have your HP-20b Business Consultant or your HP-30b Business Professional sitting on your desk unchanged as produced by HP, please turn to Appendix A for some instructions how to convert it into a full fledge WP 34S yourself
. Alternatively, if you don‘t want to bother with cables on your desk connecting it to your computer, with flashing the calculator firmware and attaching a sticky overlay, you may purchase e.g. a HP-30b -based WP 34S readily in the internet: http://www.thecalculatorstore.com/epages/eb9376.sf/en_GB/?ObjectPath=/Shops/eb9376/Products/%22WP34s%20Pack%22
(We apologize for the small font
– it allows this hyperlink fitting into one print line).
The first way may just cost your time, the second will cost you some money at the store. If you choose buying your WP 34S at the address mentioned, we (the developers) will get a modest fraction of the price. Both ways, however, are proven to work – it is your choice.
For the following, we assume the flashing is done and you hold a WP 34S in your hands.
WELCOME
Dear user, now you have got it: your own WP 34S. It uses the mechanics and hardware of the HP-20b Business Consultant or the new HP-30b Business Professional , so you benefit from their unexcelled processor speed. And with the HP-30b you get the famous rotate-and-click keys in addition, giving the tactile feedback appreciated in vintage Hewlett-Packard calculators for decades.
On the other hand, the firmware and user interface of the WP 34S were thoroughly thought through and discussed by us, newly designed and written from scratch, loaded with functions, pressed into the little memory provided, and tested over and over again to give you a fast and compact scientific calculator like you have never had before.
The WP 34S function set is based on the famous HP-42S RPN Scientific , the most powerful programmable RPN calculator built so far
1
. We expanded this set, incorporating the functionality of the renowned programmer‘s calculator HP-16C , the fraction mode of the HP-32SII , probability distributions as featured by the HP-21S , and added many more useful functions for mathematics, statistics, physics, engineering, programming etc.
like
+ Euler‘s Beta function, Fibonacci numbers, Lambert‘s W (all of these in real and complex domains), the error function, incomplete regularized Beta and Gamma,
Riemann‘s Zeta, the most ‗popular‘ orthogonal polynomials, testing for primality,
+ many statistical distributions and their inverses like Poisson, Binomial, Geometric as well as Cauchy-Lorentz, Exponential, Logistic, Weibull for reliability analysis, Lognormal and Gaussian with arbitrary means and standard deviations,
+ programmable sums and products, first and second derivatives,
+ extended date and time calculations based on a real time clock,
1
Though the HP-42S was sold in 1988 already, this statement holds still.
– Due to hardware restrictions, the matrix math of the HP-42S cannot be supported by the WP 34S. Matrices are covered, however, by a package of basic commands.
WP 34S Owner‘s Manual
Edition 2.2 Page 4 of 103
+ integer computing in arbitrary bases from binary to hexadecimal,
+ financial operations like mean rate of return and margin calculations,
+
80 conversions, mainly between universal SI and old Imperial units,
+
50 fundamental physical constants as precise as known today by national standards institutes like NIST or PTB, plus some more out of mathematics, astronomy, and surveying,
+ complete Greek and extended Latin letter fonts covering many languages on this planet (upper and lower case in two font sizes each).
The WP 34S is the first RPN calculator overcoming the limits of a 4-level stack
– forget worries about stack overflow in calculations. It features a choice of two stack sizes expanded by a complex LASTx register: traditional four stack levels for HP compatibility, eight levels for convenient calculations in complex domain, advanced real calculus, vector algebra, or for whatever application you have in your mind. You find a full set of commands for stack handling and navigation in either size.
Furthermore, your WP 34S features over 100 general purpose registers, 104 user flags, 506 program steps in working memory, more than 2500 in flash, a 31 byte alpha register for message generation, and 4 programmable hotkeys for your favorite functions or routines. And you may backup your work in battery-fail-safe memory.
Your WP 34S is the result of a long range collaboration of two individuals, an Australian and a German. We did this in our free time, so you may call it our hobby (though some people close to us found different names for this). From its very beginning, our project was discussed on the forum of the Museum of HP Calculators
( www.hpmuseum.org
), so we want to express our gratitude to all the international contributors there who taught us a lot and brought their ideas and support in several stages of our project. Special thanks go to Marcus von Cube (Germany) supporting us in bringing the WP 34S to life, starting with an emulator for v1.14, allowing widespread use and convenient testing. From v1.17 on, the software runs on the real hardware as well. A very useful assembler / disassembler is supplied by Neil Hamilton (Canada) since v1.18 and even a symbolic preprocessor was added with v2.1.
We baptized our baby WP 34S in honor of one of the most powerful LED pocket calculators, the HP-34C of 1979. The WP 34S is our humble approach – with the hardware given – to a future 43S we can only dream of becoming the successor of the
HP-42S once. May the WP 34S help in convincing those having access to more resources than us: covering the market of serious scientific instruments is worthwhile.
Firmware-wise, we have carefully checked everything we could think of to our best knowledge, so our hope may be justified the WP 34S is free of bugs. Anyway, we promise we will continue improving the WP 34S whenever it turns out being necessary – so if you discover any strange result, please report it to us, and if it is revealed to be an internal error we will provide you with an update as soon as we have got one ourselves. We did show short response times so far, and we will continue this way.
Enjoy!
Paul Dale and Walter Bonin
WP 34S Owner‘s Manual
Edition 2.2 Page 5 of 103
PRINT CONVENTIONS
Please note:
Throughout this manual, standard font is Arial. Specific terms, names or titles are printed in italics. Hyperlinks are underlined. Bold italic letters like n are used for variables. Calculator commands – e.g. ENTER – are generally called by their names, printed in capitals for easy recognition. Each and every command featured is listed in the Index of Operations below.
This font is taken for explicit references to keys.
Register addresses are printed using bold Times New Roman , while lower case italic letters of this font are employed for register contents. So, for example, y lives in stack level Y , r45 in general purpose register R45 , and alpha in the alpha register, respectively. Overall stack contents are quoted in the order [ x , y , z , …].
All this holds unless stated otherwise explicitly.
GETTING STARTED
If you know how to deal with a good old HP RPN scientific calculator, you can start with your WP 34S right away. Use the following as a reference manual.
Else we recommend you get an HP42S Owner’s Manual . It is available at low cost on the DVD distributed by the Museum of Hewlett-Packard Calculators
( www.hpmuseum.org
). There are also other sources in the internet.
Please read Part 1 of said manual as a starter. This part includes an excellent introduction to RPN. This RPN is a very effective method making , , , ,
, and keys obsolete in calculations. Once you got used to it you will most probably never employ a calculator featuring again.
Part 2 of said manual will support you when you are heading for programming your WP 34S for easy handling of repeated or iterative computations. Further documentation, also about the other calculators mentioned above and in the following text, will add valuable information – it is all readily accessible on a single
DVD from said source.
Most
―old‖ commands on your WP 34S will work as they did on the
HP-42S . This little manual here is meant as a supplement showing you all the new features. It contains all the necessary information including some formulas and technical explanations but is not intended to replace textbooks about mathematics, statistics, physics, programming, or the like.
The following text starts presenting the keyboard as it will be active in various modes, so you know where to find what you are looking for. It continues explaining the memory, addressing items therein, the display and indicators used to give you feedback what is going on. Then the major part of this booklet is taken by the index of all the operations, catalog contents, constants and conversions featured. It closes with a list of messages the WP 34S will display if special conditions prevent it from executing your command as expected.
WP 34S Owner‘s Manual
Edition 2.2 Page 6 of 103
WHAT’S ON THE KEYBOARD AND HOW TO ACCESS IT?
Let us investigate your WP 34S in default state. Take off the battery cover, locate the little RESET hole between the batteries, and use a paper clip to reset. This will erase all user contents and give you a fresh start.
As usual, white labels execute the default primary function of the respective key.
There are further
(secondary) functions provided for almost all keys.
Their labels are printed next to the white ones in golden, blue, green or grey color.
Green labels are placed on the slanted faces of most keys. Golden and blue labels are printed below of the respective key on the top face of the WP 34S, i.e. on the key plate . Grey letters are put bottom left of most keys.
Labels underlined open catalogs .
To access a golden, blue, or green label, use the prefix
, , or , respectively.
E.g. the key preceded by
will calculate the arithmetic mean values of the data accumulated in the statistic registers via ,
will return the standard deviations for the same data via ,
will open a catalog of supplementary statistic functions via .
The grey letter R will become relevant in alpha mode .
WP 34S Owner‘s Manual
Edition 2.2 Page 7 of 103
These prefixes allow for easily accessing a multiple of the 37 primary functions the keyboard can take. You may keep the respective prefix pressed if you want to call several functions in sequence showing the same label color. Any numeric entry will just fill the display and is interpreted when completed, not earlier.
Time for a small example. Please take your WP 34S and press
(i.e. the bottom left key) to turn your calculator on. You will get
Unless specified otherwise, we shall quote the numeric results only in the following, i.e. here.
Now let us assume you want to fence a little patch of land 40 feet long and 30 feet wide. You have set the first corner post (A) already, and also the second
(B) in a distance of 30 feet from A. Where do you place the third post (C) to be sure setting up the fence forming a proper rectangle? Simply enter:
(this key is for separating two numbers in input here)
( is reached via and )
So, just take a 90 feet rope, nail its one end on post A and the other one on B, fetch the loose loop and walk 40 feet away. As soon as both parts of the rope are tightly stretched, stop and place post C there. You may set the fourth post the same way.
This method works for arbitrary rectangles. Your WP 34S does the calculation of (or whatever lengths apply for you) automatically. You just care for the land, the rope, hammer and nails. And it will be up to you to set the posts!
As in this example, we will generally refer to shifted functions like by just printing the colored label in this text and omit the prefix key of corresponding color, since redundant.
By the way, by pressing the function POL is called, converting rectangular to polar coordinates. Most labels printed on your WP 34S simply call operations carrying the same name as the respective label. There are, however, also a number of cases like . Thus, let us introduce them, starting top left on the keyboard:
, , , and are called hotkeys , since they immediately call the user programs carrying these labels if defined. If the respective labels are not (yet) defined, these keys act as , , , or , respectively.
WP 34S Owner‘s Manual
Edition 2.2 Page 8 of 103
is the prefix for hyperbolic functions, as is for their inverses (see
SINH, COSH, TANH, ASINH, ACOSH, and ATANH). In analogy, stands for ASIN, etc.
is the prefix for five immediate conversions: trailed by , ,
, , or will convert x , i.e. the value currently displayed. The respective function names all begin with . And furthermore, is employed for indirect addressing.
calls REC, converting polar to rectangular coordinates in 2d. So the pair
takes care of the two classic coordinate transformations.
is mainly employed as a prefix for calling complex operations. See the respective paragraph below for more.
and enter the fraction mode for proper and improper fractions, respectively (see PROFRC and IMPFRC).
and represent the two time modes, where stands for decimal hours, but also for floating point numbers in general (see DECM).
enters alpha mode , while , , , or will enter integer modes for calculating with binary, octal, decimal, or hexadecimal numbers (see BASE…).
calls x α and α x, respectively.
calls x! in default floating point mode, toggles radix marks by calling
RDX , or RDX .
, toggles programming mode, and calls ABS.
These were all the special labels featured. You will find each and every command provided on your WP 34S below in the index of operations for your reference, together with the necessary individual explanation.
In four decades of pocket calculators, a wealth of nice to sophisticated application examples were invented and described by different authors – more and better than we can ever create ourselves. Also it is not our intention to copy these old examples.
Instead, we recommend the DVD mentioned above once more: it contains all the user guides, handbooks, and manuals of vintage Hewlett Packard calculators. Be assured that almost everything described there for any scientific calculator can be done on your WP 34S as well, just significantly faster.
Let us return to our introductory example for two remarks:
1. There is no need to enter any units. The example will work with meters as well, for example.
2. Although we entered integer numbers only for both sides of our little ground, the calculation was executed in default floating point mode of your WP 34S.
This calculator mode allows for decimal fractions of e.g. feet in input and output as well. Another mode lets you key in proper fractions like e.g. 6 ¼.
Before you suffer from feet fractions, however, we want to briefly show you some additional modes your WP 34S features (you will find a complete list of all modes provided in a separate chapter further below).
WP 34S Owner‘s Manual
Edition 2.2 Page 9 of 103
Integer modes are meant to deal with integers only – in input, output, and calculations. This is useful for computer logic and similar applications. Your WP 34S allows for binary, ternary, etc. through hexadecimal computing. In these modes, operations like SIN don‘t make sense for obvious reasons. Thus, for integer bases up to ten, the top row of keys on your WP 34S will effectively work as shown here: y
X
√
x
A B C D
MODE
In hexadecimal integer mode, primary functions of these top keys will change to become numeric input, so will be used for accessing their default primary functions: y
X
√
x
A B C D
MODE
A B C D E F
The dark red background is used to highlight changed key functionality here. Prefix
will access the default primary functions wherever they aren‘t primary anymore.
Calculating in bases 11 … 15, those keys not needed for numeric input will work as shown in the first picture above. In any integer base, attempts to enter an illegal digit
– like e.g. 4 in binary – will be blocked.
Alpha mode is designed for text entry, e.g. for prompts. In this mode, the alpha register is displayed in the upper part of the LCD, and the numeric line (kept from your last calculation) is accessible by commands only. The display may look like this:
In alpha mode, almost all the mathematical operations are neither needed nor applicable. So the keyboard is redefined automatically when you enter alpha mode, as shown overleaf.
WP 34S Owner‘s Manual
Edition 2.2 Page 10 of 103
A B
1/x
C D E F
STO
RCL
G
VIEW
H
I
f g h
ENTER
CLx
J x
K
L
CL
XEQ 7 8 9
M
▲
4
!
▼
X.FCN
( )
Q
1
TEST
EXIT 0
PSE
OFF
N
U
5
R
2
X
●
O
6
S
3
V
Y
/
P
×
STATUS
T
–
W
+
Z
All labels printed on dark red background in this picture append characters to immediately or via alpha catalogs. Alpha mode starts with capitals, and alpha
toggles upper and lower case. appends a space. Primary function of most keys is appending the letter printed bottom left of this key – grey on the key plate. Prefix will access the default primary functions there
2
.
Looking at the standard labels on the keyboard, we can safely offer more:
2
The digits 0 and 1 may also be called using or , respectively.
WP 34S Owner‘s Manual
Edition 2.2 Page 11 of 103
1/x
√
_
_ CPX
A B C D E F
STO
RCL R
VIEW R
G H
I
f g h
ENTER
±
\
CLx
J x
K
L
CL
XEQ 7 8 9 /
& |
≠
£
M N O P
▲
4
!
▼
X.FCN
( )
5 6 ×
Q
?
1
R S
$
STATUS
T
2
TEST
U
€
3
V
–
W
EXIT 0 ●
PSE
.
/
, ¥
OFF
X
Y
Z
+
All labels printed on dark blue background here append characters to alpha as well, but deviate from the labels printed on your WP 34S keyboard at these locations.
Prefix leads to homonymic Greek letters where applicable
3
. And gives access to logic symbols via the Boolean operations, to ‗!‘, to ‗?‘ at the letter Q, as well
3 ―Homonymic‖ according to ancient Greek pronunciation. And we assigned Gamma also to C due to the alphabet, and Chi to H since this letter comes next in pronunciation. Three Greek letters require special handling: Psi is accessed via (below ), Theta via (below and
WP 34S Owner‘s Manual
Edition 2.2 Page 12 of 103
as four currency symbols located next to the %-command as follows: $ at the letter S,
€ at U for Euro, £ at P, ¥ at Y for Yen or Yuan – and % at .
The catalogs , , , , , and feature even more characters (see below ). See the index of operations for αSTO, αRCL, and more alpha commands.
When alpha exceeds 31 characters, the leftmost character(s) are discarded.
A temporary alpha mode is entered during input processing in comparisons and in memory addressing, e.g. during storing. See the respective virtual keyboard here:
MODE
A B C D
I
ENTER
J
K
L
7 8
9
/
▲
4 5 6 ×
T *
▼
1 2 3
–
0
X
Y
+
Z *
This mode is left automatically when sufficient characters are put in for the respective command.
Examples are shown below .
Special rules apply for T and
Z – see below .
following T ), and Eta via . Omicron is not featured since looking exactly like the Latin letter O in either case.
– Where we printed Greek capitals with lower contrast, they look like the respective Latin letters in our fonts. Greek professors, we count on your understanding.
WP 34S Owner‘s Manual
Edition 2.2 Page 13 of 103
REAL AND INTEGER OPERATIONS
Most of the commands your WP 34S features are mathematical operations or functions in real domain. ―Real domain‖ means these functions use real numbers like 1 or
2.34 or
or 5.6E-7, and work with them. Please note integer numbers like 8, 9, 10, or
-1 are just a subset of real numbers.
Most real number functions provided operate on one number only – the number currently displayed. For example, key in
and press
since 0.7
2
= 0.49
Generally, such functions replace x (i.e. the number currently displayed) by the result f( x ) , that‘s all they do.
Some of the most popular mathematical functions, however, operate on two numbers. Think of + and – , for example. On your WP 34S, such a two-number real function replaces x by the result f( x , y ) . Now the stack enters the game. Think of it like a pile of numbers. For subtracting two numbers, you need to know them first, then you can execute the subtraction. That‘s the essence of RPN.
So having an account of 1,234 US$ and taking 56.7 US$ from it is solved as follows:
enter first number separates the two numbers in input as in the very first example above
enter second number
subtract it from the first
By , the first number is ―pushed on the stack‖ so a second separate number can be entered in sequence. The operation takes its input from the lowest two stack levels X and Y but needs only X to put its result in. Knowing your WP 34S features more than only two stack levels, level Y is then filled with the content of the next higher level, i.e. z . This goes on for higher levels, as shown below . Please note the top stack level content is repeated then (since there is nothing else available for filling). You may use this top level repetition for some nice tricks.
There are also a few three-number real functions included – e.g. Iβ and %MRR – replacing x by the result f( x, y, z ) . Then Y is filled with t and so on, and the content of the top level is repeated twice.
Some real functions (e.g. DECOMP) operate on one number but return two. Other operations (like RCL or SUM) do not consume any stack input at all but just return one or two numbers. Then these extra number(s) will be pushed on the stack, taking one level per real number.
WP 34S Owner‘s Manual
Edition 2.2 Page 14 of 103
STATISTICAL DISTRIBUTIONS, PROBABILITIES ETC.
You will find a lot of statistics in your WP 34S, going far beyond the Gaussian distribution. Many preprogrammed functions are implemented here for the first time in an
RPN calculator – we packed all in what we always had missed. All of these functions have a few features in common:
Discrete statistical distributions (e.g. Poisson, Binomial) are confined to integers.
Whenever we sum up a probability mass function ( pmf 4 ) distribution function ( cdf ) we start at . Thus,
to get a cumulated
F ( m )
m n
0 p ( n )
P
.
Whenever we integrate a function, we start at the left end of the integration interval. Thus, integrating a continuous probability density function ( pdf ) to get a cdf typically works as
F ( x )
x f
d
P
.
Typically, F starts with a very shallow slope, becomes steeper then, and runs out with a decreasing slope while slowly approaching 100%. Obviously you get the most precise results on the left side of the cdf using P . On its right side, however, the ―error probability‖
Q = 1
– P
is more precise: since P comes very close to 100% there, you may see 1.0000 displayed while e.g. P = 0.99996
in reality.
On your WP 34S, with an arbitrary cdf named XYZ you find the name XYZ
-1
for its inverse and XYZ
P
for the pdf or pmf , unless stated otherwise explicitly.
For calculating confidence limits for the ―true value‖ based on a sample evaluation, employing a particular confidence level (e.g. 95%), you must know your objective: o Do you want to know the upper limit, under which the
―true value― will lie with a probability of 95%? Then take 0.95 as the argument of the inverse cdf to get said limit, and remember there is an inevitable chance of 100%
– 95% = 5% for the ―true value‖ being greater than it. o Do you want an upper and a lower limit confining the ―true value‖? Then there is an inevitable chance of 5% / 2 = 2.5% for said value being less than the
4
In a nutshell, discrete statistical distributions deal with ―events‖ governed by a known mathematical model. The pmf then tells the probability to observe a certain number of such events, e.g. 7. And the cdf tells the probability to observe up to 7 such events, but not more.
For doing statistics with continuous statistical variables
– e.g. the heights of three-year-old toddlers – similar rules apply: Assume we know the applicable mathematical model. Then the respective cdf tells the probability for their heights being less than an arbitrary limit value, for example less than 1m.
And the corresponding pdf tells how these heights are distributed in a sample of let‘s say 1000 children of this age.
WARNING: This is a very coarse sketch of this topic only
– please turn to textbooks about statistics to learn dealing with it properly.
The terms pmf and pdf translate to German „Dichtefunktion― or „Wahrscheinlichkeitsdichte―, cdf to
„Verteilungsfunktion― or „Wahrscheinlichkeitsverteilung―.
WP 34S Owner‘s Manual
Edition 2.2 Page 15 of 103
lower limit and an equal chance for it being greater than the upper limit. So you shall use 0.025 and 0.975 as arguments in two subsequent calculations using the inverse cdf to get both limits.
If you cannot live with these chances, inevitable as they are, employ an higher confidence level.
Turn to a good statistics textbook for more information, also about the terminology used and the particular distributions provided.
MATRICES
Numbers arranged in a flat grid like in a table are called matrices by the mathematicians. If you do not know matrices, feel free to leave them aside – you can use your
WP 34S perfectly without them.
Else please note your WP 34S features a set of operations for adding, multiplying, inverting and transposing matrices, as well as for manipulating rows in such matrices.
In general, the respective commands are building blocks designed to provide the low level support routines for creating more useful matrix functions as keystroke programs. I.e. they represent the basic linear algebra subprograms of the WP 34S matrix support. There are, however, also functions featured for computing determinants as well as for solving systems of linear equations.
A matrix is represented within your WP 34S by its descriptor , formatted bb.rrcc with rr being the number of its rows and cc the number of its columns. Thus the matrix has rr × cc elements.
These elements are stored in consecutive registers starting at base address
| bb | . See below to learn about the registers of your WP 34S.
Example: A descriptor 7.0203 represents a 2×3 matrix – let us call it (M). As you know, its six elements are arranged in two rows and three columns, and are numbered as follows:
The descriptor tells us now where to find the values of these elements: m
11
= r07 , m
12
= r08 , m
13
= r09 , m
21
= r10 , m
22
= r11 , and m
23
= r12 .
If cc is omitted in a descriptor, it is set to rr so a square matrix is assumed. The maximum number of matrix elements is 100
– it is the number of general purpose registers available. A vector descriptor looks like bb.01cc or bb.rr01 .
WP 34S Owner‘s Manual
Edition 2.2 Page 16 of 103
COMPLEX OPERATIONS
Mathematicians know more complicated items than real numbers. The next step are complex numbers. If you do not know them, leave them aside – you can use your
WP 34S perfectly without them.
Else please note your WP 34S supports many operations in complex domain as well.
The key is employed as a prefix for calling complex functions. E.g.
calls the complex cosine, and it is displayed and listed as
C
COS (the elevated C is the signature for complex functions on your WP 34S). All such functions operating on complex numbers do so in Cartesian coordinates exclusively. Each complex number occupies two adjacent registers: the lower one for its real part and the higher one for its imaginary part.
Generally, if an arbitrary real function f operates on …
… one real number x only, then its complex sibling
C f will operate on the complex number x c
= x + i y .
… one register, e.g.
R12 , then
C f will operate on R12 and R13 .
… x and y , then
C f will operate on x, y, z and t .
Where one-number real functions replace x by the result f( x ) , one-argument complex functions replace result
C f( x c
) x by the real part and y by the imaginary part of the complex
. Higher stack levels remain unchanged. Such functions are
C
1/x,
C
ABS,
C
ANGLE,
C
CUBE,
C
CUBERT,
C
FIB,
C
FP,
C
IP,
C
RND,
C
SIGN,
C
W,
C
W
-1
,
C x!,
C x
2
,
C √‾ ,
C +/– ,
C Γ(x), the logarithmic and exponential functions with bases 10, 2 and e , as well as hyperbolic, trigonometric, and their inverses.
Two-number real functions replace x by the result f( x, y ) . Analogously, twoargument complex functions replace x by the real part and y by the imaginary part of the complex result
C f( x c
, y c
) . The next stack levels are filled with the complex contents of higher levels, and the complex number contained in the top two stack levels is repeated as shown below . Such complex functions are
C
LOG
X
,
C y x
,
C β(x,y), C
// , and the basic arithmetic operations in complex domain.
Where complex operations (like
C
RCL) do not consume any stack input at all but just return a complex number, this will be pushed on the stack taking two levels.
WP 34S Owner‘s Manual
Edition 2.2 Page 17 of 103
MEMORY
Mode
Alpha (31 bytes)
Display
Stack registers
D *
C *
B *
A *
T
Z
Y
X
L I **
For the first time ever in a calculator, your WP 34S offers a choice of 4 or 8 stack levels. So either T or D will be the top level.
Registers A - D will be allocated as stack registers if required.
Please see below for top level repetition and stack contents in complex calculations. While register L takes the real part of the last argument, I takes the imaginary part when a complex function was executed (see C LASTx).
Using , registers R86 R99 will contain statistical sums as indicated. J and K may be taken for parameters of statistical distributions.
Unless required for the purposes just mentioned, A - D, I, J, and
K are available as additional general purpose registers. For indirect addressing , the stack levels and named registers carry the numbers 100 … 111 as shown at right.
For information about the flags, please turn overleaf.
General purpose registers
User flags
R00
R01
R02
…
…
R85
R86 Σ ( x
2
y )
R87
Σ x
R88 Σ x ²
R89
Σ y
R90 Σ y ²
R91
Σ ( x y )
00
01
02
…
…
97
98
99
A
B Big , overflow
C Carry
D Danger
R92 n
R93
Σ (ln x )
R94 Σ (ln² x )
R95
Σ (ln y )
R96 Σ (ln² y )
R97
Σ(ln x ln y )
R98
Σ ( x ln y )
R99
Σ ( y ln x )
J
K
***
***
WP 34S Owner‘s Manual Edition 2.2 Page 18 of 103
Program steps
000
001
002
…
…
504
505
506
X = R100
Y = R101
Z = R102
T = R103
A = R104
B = R105
C = R106
D = R107
L = R108
I = R109
J = R110
K = R111
Flags 00 … 99 are free to use for whatever purpose you like.
Flags A, B, C and D may be used the same way, but the system checks them, too. Flag A lights the big ‗=‘ symbol in display. In integer modes, flags B and C will be set by the system in analogy to the overflow and carry bits of the HP-16C . Some integer operations (like shift and rotate) also read flag C. Flag D may be set by the user to allow special results (infinities and non-numeric results) without getting an error. The system only reads D.
For indirect addressing
, flags A … D carry the numbers 100 …
103.
In addition to the RAM provided, your WP 34S allows you to access flash memory for voltage-fail safe storage of user programs and data. Flash memory features up to ten segments
(regions, banks) of 1 kB each. Segment 0 is the backup region, holding the image of the entire program memory, registers and calculator state as soon as you completed a SAVE. The other segments hold programs only. Alphanumeric labels (see below) in flash can be called via XEQ like in RAM. This allows creating program libraries in flash. Use CAT to see the labels defined already.
Flash memory is ideal for backups or other long-living data, but shall not be used for repeated transient storage like in programmed loops (since it will not survive more than some 10,000 flashes). Registers and standard user program memory, residing in RAM on the opposite, are designed for frequent data changes – but will not hold data with the batteries removed. So both kinds of memory have specific advantages and disadvantages you shall take into account for optimum benefit and long lasting joy with your WP 34S.
Find more about flash memory in Appendix A below.
WP 34S Owner‘s Manual Edition 2.2
Furthermore, there is a memory section called XROM (for ―extended ROM‖), where some additional routines live. Though written in user code, these are read only and thus can be called, executed, but not edited. For you, it shall make no difference whether a preprogrammed routine executes in ROM or
XROM.
Structuring program memory and jumping around in it is eased by labels you may tag to any program steps – as known from previous programmable pocket calculators. Your WP 34S features a full set of alphanumeric labels as described below .
When a command like e.g. GTO xy is encountered, with xy representing one, two or three characters (like A, BC, 12, Tst,
Pg3, x1µ, etc.), your WP 34S will search this label xy using the following method:
1. If xy is purely numeric, it will be searched forward from the current position of the program pointer. When the end of the program space is reached without finding xy , the quest will continue at the start of the current segment. No other segments will be searched. This is as known from vintage
HP calculators.
2. Else, i.e. if xy is an alpha label of up to three characters of arbitrary case, searching will start at program step 000 and cover the entire memory in the order RAM, flash segments
8, 7, …, 1, 0, and XROM, independent of the position of the program pointer.
Page 19 of 103
STACK MECHANICS
The following assumes you are familiar with RPN
– else please turn to the
HP-
42S Owner’s Manual first.
The fate of particular stack register contents depends on the operation executed, its domain (real or complex) and the stack size chosen. Real functions in a 4-level stack work as known for decades. In a larger stack, everything works alike on your WP 34S – just with more levels for intermediate results. Please note only the contents of X are displayed in any case. See below for details of the stack mechanics:
With 4 stack levels
T
Z
Y
X
With 8 stack levels
D
C
B
A
T
Z
Y
X
Assumed stack contents at the beginning: z y a t x d c b t z y x
Stack contents after executing …
… the real stack register operations
ENTER FILL DROP x
y R
R
LASTx z x t y x t t x z z z t y y x x z x z x x x x y y y t last x
… real functions of
… one
number like x
2
… two numbers like / t z t t y x
2 z y / x c x d d x c c b x d c d b b a x c b c a a t x b a b t t z x a t a z z y x t z t y y x x z x z x x x x y y y d last x d c b a t z y x
2 d d c t z b a y / x
Calculating formulas from inside out stays a wise strategy in either stack. With more levels, however, stack overflow will hardly ever happen, even with the most advanced formulas you compute in your life as a scientist or engineer.
WP 34S Owner‘s Manual Edition 2.2 Page 20 of 103
Calculating with complex numbers uses two registers or stack levels for each such number as explained above and shown here:
Assumed stack contents at the beginning:
Stack contents after
C
ENTER
C
FILL executing …
… the complex stack register operations
C
DROP
C x
y
C
R
C
R
C
LASTx
… complex functions of
… one
number
C like x
2
… two numbers like
C
/
With 4 stack levels
T Im( y c
) = Im( t c
)
Z Re( y c
) = Re( t c
)
Y Im( x c
)
X Re( x c
)
Im( x c
)
Re( x c
)
Im( x c
)
Re( x c
) y c
= t y c c
Im( x c
)
Re(
Im( x y c c
)
)
Re( y c
) x y c c x c last x c y c
= t
Im( ( x c y c
)
2
) Im( c
= t
y c c
)
Re( ( x c
)
2
) Re( y c
/ x c
)
/ x c
With 8 stack levels
D
C
B
A
T
Z
Y
X
Im( t c
)
Re( t c
)
Im( z c
)
Re( z c
)
Im( y c
)
Re( y c
)
Im( x c
)
Re( x c
) z y x x c c c c x x c x x c c c t c t c z y c c z t x y c c c c z x t y c c c y x c z t c c c c z y x c c c last x c
( t z y x c c c c
)
2 y c z t t c c c
/ x c
So, an 8-level stack gives you the same flexibility in complex domain you are used to with a 4-level stack in real domain.
WP 34S Owner‘s Manual Edition 2.2 Page 21 of 103
COMPARING AND ADDRESSING REAL NUMBERS
1 User input , , , , ≈ , , or
,
,
,
,
,
,
,
,
, , , , , , , , ,
, , , , bit or flag commands, etc.
Dot matrix display
OP _ (with temporary alpha mode set), e.g.
OP _ (with temporary alpha mode set), e.g.
5
2 User input
Dot matrix display
or
Stack level or named reg.
,
, ...
OP n e.g.
OP x e.g.
3 User input Compares x with the number 0 .
Dot matrix display
Compares x with the number on stack level Y .
6 leaves temp. alpha mode.
OP r_
Register no.
…
OP r nn e.g.
opens indirect addressing.
Stack level or named register
, , , .. , 7
Number of register or flag or bit(s) or decimals
8
OP _
Look right for more about indirect addressing.
OP x e.g.
OP nn e.g.
Sets scientific display with the number of decimals specified in stack level Z .
Stack level etc.
, , , ... ,
OP x e.g.
9 opens indirect addressing.
OP _
Register number
…
OP nn e.g.
Compares x with the number stored in R23 .
Shows the content of the register where L is pointing to.
Stores x into the location where R45 is pointing to.
5
For and , any of , , , , , or may precede step 2, except in RCLM and STOM. calls αVIEW, And calls ENGOVR, calls SCIOVR. See the index of operations.
6
You may skip this for register numbers >19.
7
Exceptions: RCL T, RCL× T, RCL Z, RCL+ Z require an preceding or , e.g. for the latter. This holds for STO as well.
8
Legal register numbers are 00 … 111 (00 … 99 may be specified directly). Valid flag numbers are 00 … 103 , with the four top flags directly addressed via ,
, , and . Legal numbers of decimals are 0 … 11, accepted integer bases 2 … 16, bit numbers 0 to 63, and integer word size up to 64 bits. For numbers
<10, you may key in e.g. instead of . – Please take into account some registers may be allocated to special applications.
9
Works for all commands taking a parameter or argument except DEL
P
.
WP 34S Owner‘s Manual Edition 2.2 Page 22 of 103
COMPARING AND ADDRESSING COMPLEX NUMBERS
1 User input
Dot matrix display
or
OP _ (with temporary alpha mode set) e.g.
,
, or
OP _ (with temporary alpha mode set) e.g.
10
2 User input
Dot matrix display
or
OP n e.g.
Stack level or named register
, , , ,
, or
OP x e.g.
OP r_
11 leaves temp. alpha mode
opens indirect addressing.
OP _
3 User input
Compares x + i y with the real number 0 .
Compares x + i y with z + i t .
Register number
…
Look right for more about indirect addressing.
Dot matrix display
OP r nn e.g.
Stack level or named register
12
, , ,
, or
Register number
..
13
OP x e.g.
This is
C
LASTx.
OP nn e.g.
Stack level or named register
,
, ... ,
opens indirect addressing.
OP _
Register number
…
OP x e.g.
OP nn e.g.
Compares x + i y with r26 + i r27 .
Swaps x with the contents of the register where Z is pointing to, and y with the contents of the next one.
Stores x + i y into
2 consecutive registers, starting with the one where R45 is pointing to.
10
For and , any of , , , or may precede step 2. See the index of operations.
11
You may skip this keystroke for register numbers >19.
12
Exceptions:
C
RCL Z,
C
RCL + Z,
C
STO Z, and
C
STO + Z require an preceding , e.g. for the latter.
13
You may key in e.g. instead of . Take care of pairs, since a complex operation will always affect two registers: the one specified and the one following this. We strongly recommend storing complex numbers with their real parts at even register numbers. – Please take into account some registers may be allocated to special applications.
WP 34S Owner‘s Manual Edition 2.2 Page 23 of 103
ADDRESSING LABELS
1 User input
Dot matrix display
, , , or
XEQ label e.g.
, , , , ,
OP _
, e.g.
, , or
2 User input
Dot matrix display
3 User input
Dot matrix display
Calls the function labeled C .
, , , or sets alpha mode.
14 opens indirect addressing and sets temporary alpha mode.
OP _ OP label e.g.
OP ‘_
Sums up the function labeled B .
Alphanumeric label
( 1 … 3 characters 15
)
OP ‘ label ’ e.g.
Stack level or named register
, , , ... ,
OP x e.g.
Register number
… 16
OP nn e.g.
2-digit numeric label
…
OP nn e.g.
Solves the function F1µ
(with F1µ keyed in as explained in footer).
Integrates the function whose label is on stack level T .
Executes the routine whose label is in R44 .
Additionally, see above for the way your WP 34S searches labels, and look up GTO in the index of operations for two special cases applying to this command exclusively.
14
Works with all these operations except .
15
The 3 rd
character terminates entry and closes alpha mode again – shorter labels need a closing . For the example given here you just press
and you are done. Statements including alpha labels decrement the number of free program steps by 2. –
WARNING: LBL A and LBL‘A‘ are different animals! The latter is entered in alpha mode, the first via the hotkey directly.
16
Some registers may be allocated to special applications. Please check the memory table above.
WP 34S Owner‘s Manual Edition 2.2 Page 24 of 103
DISPLAY AND MODES
The display features three sections: numeric, dot matrix and fixed symbols. The numeric section features a minus sign and 12 digits for the mantissa, as well as a minus sign and
3 digits for the exponent. The dot matrix is 6 dots high and 43 dots wide, allowing for some 7 to 12 characters, depending on their widths. The fixed symbols (except the big
―=‖) are called annunciators , and are for indicating modes.
The dot matrix section above is used for
1. indicating some more modes than the annunciators allow,
2. passing additional information to the user.
The numeric section in the lower part of the LCD is used for displaying numbers in different formats, for status, or messages.
If two or more requests concur for display space, the items will be shown according to their priorities as follows:
1. error messages as described in a paragraph further below ,
2. special information as explained below,
3. information about the modes the calculator is running in.
The annunciators or specific characters in the LCD signal the modes:
Integer base or mode name
2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 DECM
Signal ed by … in the exponent b 3 4 5 6 7 o 9 d -1 -2 -3 -4 -5 h
Set by … BASE3, … , BASE7, , BASE9, , … , BASE15
Cleared by … any other BASE setting, FRACT, , .
, , , , and TIME will set DECM
Mode name PRG
Signal ed by … STO INPUT 360 RAD G
FRC
Set by …
Cleared by …
ON
OFF
,
2 nd in input
BASE1, FRACT
BASE ≠ 1
, TIME,
, , ,
WP 34S Owner‘s Manual
Edition 2.2 Page 25 of 103
BEG indicates the program pointer standing at step 000 of program memory. A running program is signaled by a flashing RCL annunciator. RPN may be lit permanently. Time modes (12h / 24h) are seen in the time string directly. The numeric format of fraction mode is unambiguous as well. Further settings are signaled in the dot matrix section, like the different date modes being indicated there by Y.MD
or M.DY
. Defaults D.MY and
DECM are not indicated. Please check the examples below.
Some mode and display settings may be stored and recalled collectively by STOM and
RCLM. These are stack depth and contrast set, complete decimal display settings, trig mode, choices for date and time display, the parameters of integer and fraction mode, curve fitting model and rounding mode selected. STOM stores this information in the register you specify. RCLM recalls the contents of such a register and sets the calculator modes accordingly. Please note the user is responsible for recalling valid mode data – else your WP 34S may be driven into a lockup state! See the index of operations for more information about changing modes and the individual commands employed.
Some regional combinations may be set at once using a single command:
SETCHN sets 24h, Y.MD, decimal point, and E3OFF;
SETEUR sets 24h, D.MY, decimal comma, E3ON, and JG1582 (these settings apply also to South America);
SETIND sets 24h, D.MY, decimal point, E3OFF, and JG1752;
SETUK sets 12h, D.MY, decimal point, E3ON, and JG1752.
SETUSA sets 12h, M.DY, decimal point, E3ON, and JG1752;
Please note the people living in the area of the former Soviet Union, in South Africa, Indonesia, and Vietnam use the decimal comma as well, but have different settings for dates and times.
Especially the angular modes deserve a closer look: there are three of them, DEG, RAD, and GRAD. And degrees (DEG) may be displayed in decimal numbers as well as in hours, minutes, seconds and hundredth of seconds (H.MS). Conversions are provided for going from one to the other: to
From degrees
H.MS decimal degrees radians gon
(grad) current angular mode degrees H.MS — H.MS — — — decimal degrees radians
H .d
— °
—
rad rad °
—
G ° DEG
G rad RAD gon/grad current angular mode
—
—
° G rad G —
DEG RAD GRAD
GRAD
—
WP 34S Owner‘s Manual
Edition 2.2 Page 26 of 103
Please see the index of operations for the commands printed on white background, and the catalog of unit conversions for those printed on yellow.
Some commands and modes use the display in a special way. They are listed below in order of falling priority:
1. VERS generates a display similar to the one shown on the title page of this manual.
Pressing any key will delete this message and return to previous state.
2. SHOW displays the full mantissa of x , i.e. all sixteen digits present internally. E.g.
returns
.
Pressing any key will return to previous display.
3. STATUS shows the status of 30 user flags very concisely in one display, allowing an immediate status overview after some training. If e.g. flags 2, 3, 5, 7, 11, 13, 14, 17,
19, and 23 are set, and labels B, C, and D are defined in program memory, STATUS will display this:
Within the numeric section, each row of horizontal bars in the mantissa shows the status of 10 flags. When a flag is set, the respective bar turns black. So here the top row of bars indicates flags 0 and 1 are clear, 2 and 3 set, and flag 4 clear. Then, the divider II separates the first group of five flags from the next. Top row bars on its right side indicate flags 5 and 7 are set. Next row of bars shows flags 11, 13, 14, 17, 19 are set, and in the lowest row only flag 23 is set. All other flags in the range from 10 to 29 are clear.
Scrolling down by will display flags 10 - 39, then 20 - 49 etc. until 70 - 99, 80 - D, and 90 - D. Scrolling up by reverts this. Alternatively, pressing a digit, e.g. 5, will show up to 30 flags starting with 10 times this digit, e.g. flags 50 - 79. The numeric exponent always indicates the status of the hotkeys top left on the keyboard – if all four labels are used in program memory then ALL will be displayed there.
The status will be displayed until any key is pressed but , , or a digit.
4. During command input , the dot matrix displays the command chosen until input is completed, i.e. until all required trailing parameters are entered. The prefixes , , and are shown until they are resolved. If you pressed any of , , or erroneously, recovery is as easy as follows: o = NOP = = = = o = =
= =
= =
WP 34S Owner‘s Manual
Edition 2.2 Page 27 of 103
In addressing, progress is recorded as explained in the tables above in detail. You may cancel such pending operations by as described below .
5. In programming mode , the numeric display indicates the program step (000 – 505) in the mantissa and the number of free steps in the exponent, while the dot matrix shows the command contained in the respective step, e.g.:
6. For floating point decimal numbers , the mantissa will be displayed adjusted to the right, the exponent to the left. Within the mantissa, either points or commas may be selected as radix marks
17
, and additional marks may be chosen to separate thousands. Assume the display set to FIX 4, then 12.345678901 millions may look like:
or with thousands separators on, and without them like:
or
These separators may also be beneficial in integer or fraction modes described below. – With ENG 3 and after changing the sign, the same number will look like this:
or
If the last operation executed was a complex one, a capital C is displayed top left in the dot matrix pointing to the fact that you find the result of this function in X and Y .
Floating point decimal numbers within
Using a decimal mantissa, even numbers down to 10
–394
may be entered easily.
can be keyed in. The calculator works with numbers down to 10
For results
–398
correctly. Smaller values are set to zero.
, error 4 or 5 will appear (see below ).
7. In integer modes , numbers are displayed adjusted to the right as well. Word size and complement setting are indicated in the dot matrix using a format xx.ww
, with xx being 1c or 2c for 1‘s or 2‘s complement, respectively, un for unsigned, or sm for sign-and-mantissa mode. Sign and first digit of the exponent show the base, a ―c‖ in the second digit signals a carry bit set, an ―o‖ in the third an overflow. Integer bases are indicated as follows:
17
Starting here, decimal input is written using a point as radix mark throughout this manual, although significantly less visible, unless specified otherwise explicitly. By experience, the „comma people― are more capable to read radix points and interpret them correctly than vice versa.
WP 34S Owner‘s Manual
Edition 2.2 Page 28 of 103
Base 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Sign and 1 st
digit of exponent displayed b 3 4 5 6 7 o 9 d -1 -2 -3 -4 -5 h
The example shows the WP 34S displaying an arbitrary number in unsigned hexadecimal mode with word size 64 and carry set:
After changing to binary mode, this number will need 28 digits, being
1001001110100001010010110110. The 12 least significant digits will be displayed initially together with an indication that there are three display windows in total with the rightmost shown:
Now press and you will get the next 12 digits in the middle window:
Press again to show the most significant digits:
If leading zeros were turned on, there will be six display windows in this case, with the three ―most significant‖ containing only zeros.
Please note numeric input is limited to 12 digits in any integer base.
8. Fraction mode works similar to HP-35S. In particular, DENMAX sets the maximum allowable denominator (see the index of operations ). Display will look like in the examples below. If the fraction is exactly equal, slightly less, or greater than the floating point number converted, ―=‖, ―Lt‖, or ―Gt‖ is indicated in the exponent, respectively.
This mode can handle numbers with absolute values < 100,000 and > 0.0001. Maximum denominator is 9999. Underflows as well as overflows will be displayed in the format set before fraction mode was entered.
Now assume your WP 34S being reset. Key in -47.40625 and you will see:
or after : .
Please note integers like 123 will be displayed as ―123 0/1‖ or ―123/1‖ in fraction mode, respectively, to indicate this mode.
Squaring the improper fraction shown above results in
WP 34S Owner‘s Manual
Edition 2.2 Page 29 of 103
Now, enter for converting this result into a proper fraction. You will get with a little hook left of the first digit shown. This indicates the leading number is displayed incompletely
– there are at least two digits preceding 47 but no more display space. Press to unveil the integer part of this proper fraction is 2247.
Input in fraction mode is straightforward and logically coherent:
Key in: and get in proper fraction mode:
( = 0.12 )
( = 1
0
/
2
! )
For comparison, please note the HP-32SII reads the last input here as ½ – which is, however, not consistent with its other input interpretations in fraction mode.
9. In H.MS display mode , format is hhhh°mm'ss.dd" with the number of hours or degrees limited to 9000. Output may look like this:
or depending on the radix setting. For decimal times less than 5ms or 0.005 angular seconds but greater than zero, an ―u‖ for underflow will be lit in the exponent section.
For times or angles exceeding the upper limit, an ―o‖ will be shown there signaling an overflow, and the value is displayed modulo 9000.
10. Output of the function WDAY will look as follows for an input of 1.13201 in M.DY mode (equivalent to inputs of 13.01201 in D.MY or 2010.0113 in Y.MD):
Expect similar displays after DAYS+. – Dates before the year 8 may be indicated differently to what they really were due to the inconsistent application of the leap year rule before this.
WP 34S Owner‘s Manual
Edition 2.2 Page 30 of 103
11. In alpha mode , the alpha register is displayed in the dot matrix, showing the last characters it is containing, while the numeric section keeps the result of the last numeric operation, e.g.:
Different information may be appended to alpha . See the commands starting with in the index of operations below
. E.g. αTIME allows creating texts like
―α‖
or depending on time mode setting (12h / 24h). And αDATE will append – depending on date format setting – either 2011-04-16 or 16.04.2011 or 04/16/2011 to alpha .
Please note alpha may contain up to 31 characters. And your WP 34S features a rich set of special letters. So you may easily store a message like
Use and for browsing it in steps of 6 characters. Browsing to the left will stop with the very first characters shown, browsing to the right stops showing the right end completely, i.e. in this very special case.
All keyboard input will be interpreted according to the mode set at input time.
WP 34S Owner‘s Manual
Edition 2.2 Page 31 of 103
FONTS
Your WP 34S features a large and a small font. Both are based on Luiz Viera‘s fonts as distributed in 2004. Some letters were added and some modified for better legibility, since the dot matrix is only 6 pixels high here. The following tables show the characters directly accessible through the keyboard:
A B C D E F G H I J K L M N O P Q R S T U V W X Y Z a b c d e f g h i j k l m n o p q r s t u v w x y z
Α Β Γ Γ Δ Ε Ζ Θ Η Κ Λ Μ Ν Ξ Ο Π Ρ Σ Τ Φ Υ Φ Χ
α β γ δ ε δ ε ϑ ι κ λ μ ν ξ ο π π ζ η υ θ χ ψ ω
0 1 2 3 4 5 6 7 8 9 ( ) + - × / ± . ! ? % √ \ & | ≠ $ € £ ¥
More characters live in the alpha catalogs you find below .
WP 34S Owner‘s Manual
Edition 2.2 Page 32 of 103
INDEX OF OPERATIONS
All commands available are found below with their names and keystrokes necessary.
Names printed in bold face in this list belong to functions directly accessible on the keyboard, the other commands may be picked from catalogs. The command names will show up identically catalogs and in program listings unless specified otherwise explicitely. Sorting in index and catalogs is case insensitive and works in the following order:
␣ , 0…9, A…Z, …
, ( ) +
– ×
/ ± , . ! ? : ;
‗ ― # * @ _ ~
< ≤ = ≠ ≥ > % $ € £ ≦ √ ∫ ∞ & \ ^ | G [ ] { }
Super- and subscripts are handled like normal characters in sorting. The fifth last item in the sorting order list above is the indicator for the angular mode GRAD.
Generally, functions and keystroke programming will work as on HP-42S , bit and integer functions as on HP-16C , unless stated otherwise under remarks. Especially, all tests will return ―true‖ or ―false‖ in the dot matrix if called from the keyboard; if called in a program, they will skip the next program line if the test is false. Please refer to the manuals of the vintage calculators mentioned for additional information about traditional commands.
Functions available on the WP 34S for the first time on an RPN calculator are highlighted yellow under remarks, while operations carrying a familiar name but deviating in their functionality here are marked light red.
Parameters will be taken from the lowest stack level(s) unless mentioned explicitly in the 2 nd
column – then they must follow the command. If underlined , they may also be specified using indirect addressing, as shown in the tables above. Some parameters of statistical distributions must be given in registers J and K if specified.
In the following, each function is listed stating the mode(s) it will work in, abbreviated by their indicators
. In this column an ―&‖ stands for a Boolean AND, a comma for an OR, and a backslash for ―not‖. So e.g. 2 X
works in all modes but alpha. All operations may also be entered in mode PRG unless stated otherwise explicitly.
Name Keys to press
C …
10 x
12h
1COMPL
1/x
…
…
… in modes Remarks
DECM
Indicates an operation allowing complex input(s) and/or complex results (see above ). The prefix
may be heading all functions whose names are printed in italics in this list .
DECM
\
\
DECM
Sets 12h time display mode meaning 1:23 becomes 1:23 AM and 13:45 becomes 1:45 PM.
This makes a difference in αTIME only.
Sets 1‘s complement mode like in HP-16C .
DECM Shortcut as long as label B is not defined yet.
WP 34S Owner‘s Manual
Edition 2.2 Page 33 of 103
Name Keys to press in modes Remarks
24h … \
Sets 24h time display mode meaning 1:23 AM becomes 1:23, and 1:45 PM becomes 13:45.
Sets 2‘s complement mode like in HP-16C . 2COMPL …
2 x
A - C
x
ABS
\
\
\
Returns the absolute value.
ACOS
ACOSH
ALL
AGM …
n
DECM Returns r
x
2 y
2 in X and clears Y .
DECM Returns arccos
.
DECM
Inverse hyperbolic cosine, known as arcosh .
Note there is no need for pressing here.
DECM
\
Returns the arithmetic-geometric mean of x and y .
ALL 00 works like ALL in HP-42S . For x > 10
13
, however, display will switch to SCI or ENG with the maximum number of digits necessary (see
SCIOVR / ENGOVR). The same will happen if
and more than 12 digits are required to show x completely.
AND
Integer Works bitwise as in HP-16C .
DECM
Works like AND in HP-28S , i.e. x and y are interpreted before executing this operation. 0 is
―false‖, any other real number is ―true‖.
ANGLE …
ASIN
DECM
Returns the angle between positive x-axis and the straight line from the origin to the point
( x, y ) , i.e. . This is a two-number function, it consumes y .
DECM Returns arcsin
.
ASINH
ASR ASR n Integer
ATAN
Works like n (up to 63) consecutive ASR commands in HP-16C, c orresponding to a division by 2 n
. ASR 0 executes as NOP, but loads L .
DECM Returns arctan
.
ATANH
DECM Inverse hyperbolic sine, known as arsinh .
DECM Inverse hyperbolic tangent, known as artanh .
WP 34S Owner‘s Manual
Edition 2.2 Page 34 of 103
Name Keys to press
BACK BACK n in modes Remarks
PRG
Jumps n program steps backwards (1 ≤ n ≤ 99).
So e.g. BACK 01 goes to the previous step.
Reaching step 000 stops program execution.
BASE BASE n
BASE10
BASE16
BASE2
BASE8
BATT
…
\
Sets the base for integer calculations, with
2 ≤ n ≤ 16. Popular bases are directly accessible on the keyboard. Current integer base setting is indicated in the exponent as explained above .
Furthermore, BASE0 equals DECM, and BASE1 calls FRACT. See below.
ATTENTION: Going from DECM to any integer mode, the current stack contents will be truncated. Going from integer to DECM, the current stack contents will be converted. Other register contents will not!
DECM
Measures the battery voltage in the range between 1.9V and 3.4V and returns this value.
Integer As above but returns the voltage in 0.1V units.
BC? BC?
n Integer Tests the specified bit in x .
BestF … DECM
Selects the best curve fit model, maximizing the correlation like BEST does in HP-42S .
Binom
Binom
P
…
Binom
–1
B n
…
DECM
Binomial distribution with the number of successes g in X , the probability of a success p
0
in
J and the sample size n in K :
Binom
P
18
returns p
B
( g ; n ; p
0
)
n g
p
0 g
1
p
0
n
g
.
Binom returns F
B
( m ; n ; p
0
)
g m
0 p
B
( g ; n ; p
0
) , with the maximum number of successes m in X .
Binom
–1
returns m for given probabilities F
B
in X and p in J with sample size n in K .
DECM
Returns the Bernoulli number for an integer n >
0 given in X :
B n
n
1 n
1
n
. See below for δ.
18
The pmf equals BINOMDIST( g; n; p
0
; 0 ) and the cdf BINOMDIST( m; n; p
0
; 1 ) in MS Excel.
WP 34S Owner‘s Manual
Edition 2.2 Page 35 of 103
Name Keys to press in modes Remarks
B n
* … DECM
Returns the Bernoulli number according to its old definition for integer n > 0 given in X :
B n
*
2
2
2 n
!
. See below for δ.
BS? BS?
n Integer Tests the specified bit in x .
Cauch
Cauch
P
Cauch
–1
… DECM
Cauchy-Lorentz distribution (also known as Lorentz or Breit-Wigner distribution) with the location x
0
specified in J and the shape
in K :
Cauch
P returns f
Ca
1
1
1
x
0
2
,
Cauch returns F
Ca
1
2
1
arctan
x
x
0
.
Cauch
–1 returns x for a given probability F
Ca
in X , with location x
0
in J and shape
in K .
CB CB n Integer Clears the specified bit in x .
CEIL … DECM Returns the smallest integer ≥ x .
CF CF n \
Clears the flag specified.
CLALL …
CLFLAG …
\PRG
\
Clears all registers and programs if confirmed.
Clears all user flags.
CLP
\PRG
Positions the program pointer to step 000 and clears the subroutine return stack.
PRG
Clears the program memory if confirmed. Not programmable.
CLREG … All
Clears all general purpose registers. The stack and its contents are kept.
CLSTK \
Clears all stack registers, i.e. X through T or
X through D , respectively. All other register contents are kept.
CLx
CL
…
All
All
Clears X only, disabling stack lift as usual.
Clears the alpha register like CLA in HP-42S .
CLΣ DECM
Clears all statistical sums in the respective general purpose registers.
WP 34S Owner‘s Manual
Edition 2.2 Page 36 of 103
Name Keys to press
COMB
CONJ …
CORR
COS
COSH
COV …
CUBE …
D - F
CUBERT …
DATE …
DAY …
DAYS+ …
DBLR
DBL × …
DBL / in modes Remarks
DECM
Returns the number of possible sets of y items taken x at a time.
No item occurs more than once in a set, and different orders of the same x items are not counted separately.
Formula: C y , x
y x
x !
y !
y
x
!
DECM
DECM
Changes the sign of y , thus returning the complex conjugate of x c
.
Returns the correlation coefficient for the current statistical data and curve fitting model.
DECM Returns the cosine of the angle in X .
DECM Returns the hyperbolic cosine of x .
DECM
Returns the population covariance for two data sets. It depends on the fit model selected. For
LinF, it calculates
COV xy
1 n
2
n
x i y i
x i
y i
See s xy
for the sample covariance.
Returns x
3
. \
\
DECM
Returns .
Recalls the date from the real time clock and displays it in the numeric section in the format selected. See D.MY, M.DY, and Y.MD.
The function DATE of HP-12C corresponds to
DAYS+ in your WP 34S (see below).
DECM
Assumes x containing a date in the format selected and extracts the day.
DECM
Works like DATE in HP-12C , adding x days on a date in Y in the format selected and displaying the resulting date including the day of week in the same format as WDAY does.
Integer
Double precision commands for remainder, multiplication and division like in HP-16C .
WP 34S Owner‘s Manual
Edition 2.2 Page 37 of 103
Name
DEC
Keys to press
DEC r \ in modes Remarks
Decrements r by one, equivalent to 1 STO – r , but without modifying the stack.
DECM \
Sets default decimal mode for calculations.
DECOMP
DEG
DEG
DENANY
DENFAC
DENFIX
DENMAX
…
…
…
…
…
…
FRC
Decomposes x (after converting it into an improper fraction, if applicable), resulting in a stack
[ numerator( x ), denominator( x ), y, z ] or
[ num( x ), den( x ), y, z, t, a, b, c ] , respectively.
Reversible by division.
DECM Sets angular mode to degrees.
DECM
Takes x as degrees and converts them to the angular mode currently set.
\
\
\
Sets default fraction format like in HP-35S , allowing maximum precision. Any denominator up to the value set by DENMAX may appear.
Sets ―factors of the maximum denominator‖.
With e.g. DENMAX = 60, possible denominators are 2, 3, 4, 5, 6, 10, 12, 15, 20, 30, and 60.
Sets fixed denominator format, i.e. the denominator equaling DENMAX always.
\
Works like / c in HP-35S , but maximum denominator settable is 9999. It will be set to this value if x < 1 or x > 9999 at execution time. For x = 1 the current setting is recalled.
DET … \
Takes a descriptor of a square matrix in X and returns the determinant of the matrix. The matrix is not modified.
DISP
DROP
DSE
…
r
DISP n DECM
\
Changes the number of decimals shown while keeping the basic display format (FIX, SCI,
ENG) as is. With ALL set, DISP will change the switchover point (see ALL).
Drops x . See above for details and
C
DROP.
PRG
Given cccccc.fffii
in r , DSE decrements r by ii , skipping next program line if then ccccccc ≤ fff . If r features no fractional part then fff is 0 and ii is set to 1.
Note that neither fff nor ii can be negative, and DSE makes only sense with cccccc > 0.
WP 34S Owner‘s Manual
Edition 2.2 Page 38 of 103
Name Keys to press
DSL DSL r
DSZ DSZ r
D.MY
D J
D R
…
… in modes Remarks
PRG Works like DSE but skips if ccccccc < fff .
PRG
Decrements r by one, and skips if reafter .
Known from the HP-16C . r
1 the-
\
Sets the format for date display.
DECM
Takes x as a date in the format selected and converts it to a Julian day number according to
JG…
DECM
Please see the catalog of conversions below for conversions from degrees to radians.
E3OFF
E3ON
…
ENG n
\
\
Toggle the thousands separator (either a point or a comma depending on the radix setting).
ENGOVR \
Sets engineering display format.
Numbers exceeding the range displayable in
ALL or FIX will be shown in engineering format.
See SCIOVR.
ENTER
\
ENTRY? … All
See above for details.
Checks the entry flag. This internal flag is set if:
any character is entered in alpha mode, or
any command is accepted for entry (be it via , a function key, or with a partial command line). erf
… erfc
DECM
Returns the error function or its complementary: erf
2
x
0 e
2 d
and erfc
1
erf ( x )
ERR ERR n
EVEN? e x
…
PRG
Raises the error specified and clears the return stack. See below for the respective error codes.
\
DECM
Checks if x is integer and even.
ExpF … DECM
Selects the exponential curve fit model y
a
0 e a
1 x
.
WP 34S Owner‘s Manual
Edition 2.2 Page 39 of 103
Name
Expon
Expon
P
…
Expon
– 1
Keys to press
EXPT in modes Remarks
DECM
Exponential distribution with the rate
in J :
Expon
P
19
returns f
Ex
e
x
,
Expon returns F
Ex
1
e
x
.
Expon
–1
returns the survival time t s probability F
Ex
in X and rate
in J . for a given
DECM
Returns the exponent h of the number displayed
. Compare MANT.
FP e x
-1
FAST
e
X
-1
...
DECM
All
FB FB n Integer Inverts (―flips‖) the specified bit in x .
FILL
FIX
FC?
FC?C
FC?F
FC?
n etc.
\
FC?S
FF FF n \
FIB … \
n
\
\
FLOOR …
Tests if the flag specified is clear. Clears, flips, or sets this flag after testing, if applicable.
Flips the flag specified.
Returns the Fibonacci number F x
.
Copies x to all stack levels. See details above .
Sets fixed point display format.
DECM Returns the largest integer ≤ x .
Returns more accurate results for the fractional part of e
X
with x ≈ 0 .
Sets the processor speed to ―fast‖. This is startup default and is kept for fresh batteries.
FP? …
DECM Returns the fractional part of x .
\
Tests x for having a nonzero fractional part.
FRACT … \
Sets fraction mode like in HP-35S, but keeps display format as set by PROFRC or IMPFRC.
FS?
FS?C
FS?F
FS?
n etc.
FS?S
\
Tests if the flag specified is set. Clears, flips, or sets this flag after testing, if applicable.
19
The pdf corresponds to EXPONDIST( x;
; 0 ) and the cdf to EXPONDIST( x;
; 1 ) in MS Excel.
WP 34S Owner‘s Manual
Edition 2.2 Page 40 of 103
Name Keys to press in modes Remarks
G - I
F
P
(x)
F(x)
F
– 1
(p)
… DECM
F-distribution. The cdf F(x) equals 1 - Q(F) in
HP-21S . The degrees of freedom are specified in J and K . f ‘(x) f ‖(x)
f ‖(x) label
f ‘(x) label
GCD … \
DECM
Return the first or second derivative of f( x ) , respectively, with the function f(x) being specified in a routine starting with LBL label . The return stack will have y , z , and t cleared and the position x in L .
Either command will attempt to call a user routine labeled ' δx' to provide a fixed step size dx . If that routine is not defined, a step size of 0.1 is employed instead.
Returns the Greatest Common Divisor of and y . x
Geom
Geom
P
…
Geom
–1
GRAD
DECM
Geometric distribution:
Geom
P
returns f
Ge
p
0
1
p
0
m
,
Geom returns F
Ge
1
1
p
0
m
1
, being the probability for a first success after m = x
Bernoulli experiments. The probability p
0
for a success in each such experiment must be specified in J .
Geom
–1
returns the number of failures f before the first success for given probabilities F
Ge
in X and p
0
in J .
DECM Sets angular mode to gon or grads.
GRAD
GTO
… DECM
Takes x as given in gon or grads and converts them to the angular mode currently set.
label
,
, , or
nnn
\
PRG Inserts an unconditional branch to label .
\PRG, \
Positions the program pointer to label .
… to one of these labels, if defined.
Positions the program pointer …
(not programmable).
… to step nnn .
… to step 000 .
GTO
… \
Takes the first three characters of alpha (or less if there are less available) as a label and positions the program pointer to it.
WP 34S Owner‘s Manual
Edition 2.2 Page 41 of 103
Name Keys to press
H n
… in modes Remarks
DECM
Hermite's polynomials for probability:
H n
n e x
2
2 d n
dx n e
x
2
2
with n in Y , solving the differential equation f "
2 x
f '
2 n
f
0 .
H.MS
H np
…
DECM
Hermite's polynomials for physics:
H np
n e x
2 d dx n n e
with n in Y .
DECM
Assumes X containing decimal hours or degrees, and displays them converted in the format hhhh°mm’ss.dd” as shown in the paragraph above . Will return to the previous decimal display with the next keystroke thereafter.
H.MS+
H.MS
–
…
IBASE? …
IMPFRC
INC
INTM?
INC
…
r \
DECM
Assumes X and Y containing times or degrees in the format hhhh.mmssdd
, and adds or subtracts them, respectively.
\
Returns the integer base set (see BASE).
\
Sets fraction mode allowing improper fractions in display (i.e.
5
/
3
instead of 1
2
/
3
). Converts x according to the settings by DEN… Absolute decimal equivalents of x must not exceed 100,000.
Compare PROFRC.
FRC
Allows displaying improper fractions. Thus converts a proper fraction in X into the equivalent improper fraction, if applicable.
\
Increments r by one, equivalent to 1 STO+ r , but without modifying the stack.
Tests if your WP 34S is in an integer mode.
IP
INT?
ISE
…
ISE r
\
Tests x for being an integer, i.e. having a fractional part equal to zero. Compare FP?.
DECM Returns the integer part of x .
PRG Works like ISG but skips if ccccccc ≥ fff .
WP 34S Owner‘s Manual
Edition 2.2 Page 42 of 103
Name
ISG
Keys to press
r
ISZ ISZ r
I β …
I Γ …
J - L
JG1582
…
JG1752 in modes Remarks
PRG
Given cccccc.fffii
in r , this function increments r by ii , skipping next program line if then ccccccc > fff .
If r features no fractional part then ii is set to 1.
Note that neither fff nor ii can be negative, but cccccc can.
PRG
Increments r by one, skipping next program line if then r
1 .
Known from the HP-16C .
DECM
DECM
DECM
Returns the regularized incomplete beta function
x
x , y ,
z
1
x
0 t y
1
1 t z
1 dt with
x being the incomplete beta function and
being Euler‘s beta (see below).
Returns the regularized incomplete gamma function
x ,
y
with
y
0 t x
1 e
t dt being the lower incomplete gamma function. For
see below.
These two commands reflect different dates the
Gregorian calendar was introduced in different large areas of the world. D J and J D will be calculated accordingly.
J D
KEY?
…
KEY? a
DECM
Takes x as a Julian day number and converts it to a date according to JG... in the format selected
All
Tests if a key was pressed while a program was running or paused. If no key was pressed, the next program step after KEY? will be executed, else it will be skipped and the code of said key will be found in address a . Key codes start top left and correspond to the rows and columns on the keyboard – so e.g. corresponds to 11,
to 16, to 21, and to 75.
WP 34S Owner‘s Manual
Edition 2.2 Page 43 of 103
Name Keys to press in modes Remarks
KTY? KTY? a All
Assumes a key code in address a . Checks this code and returns
0 … 9 if it corresponds to a digit … ,
10 if it corresponds to , , or ,
11 if it corresponds to , , or ,
12 if it corresponds to any other key.
May help in user interaction with programs.
LASTx \
See above for details.
LBL label
LBL?
LBL?
label
All
PRG
Identifies programs and routines for execution and branching. See opportunities for specifying label in the table above .
Tests for the existence of the label specified, anywhere in program memory. See opportunities for specifying label in the table above .
LCM … \
Returns the Least Common Multiple of x and y .
LEAP?
LgNrm
LgNrm
P
LgNrm
– 1
LINEQS
LinF
LJ
…
…
…
…
…
DECM
DECM
Takes x as a date in the format selected, extracts the year, and tests for a leap year.
Lognormal distribution with in J and
ln x g
specified
ln
in K . See x g and
below.
LgNrm
P
returns f
Ln
x
1
2
e
ln x
2
2
2
,
LgNrm returns F
Ln
ln x
with
Φ( z ) denoting the standard normal cdf .
LgNrm
– 1
returns x for a given probability F
Ln
in
X , µ in J , and σ in K .
\
Takes a base register in X , a vector descriptor in
Y , and a descriptor of a square matrix in Z .
Solves the system of linear equations
and returns the filled out vector descriptor in X .
DECM Selects the linear curve fit model y
a
0
a
1 x .
Integer Left adjust as in HP-16C .
LN DECM
Returns the natural logarithm of x , i.e. the logarithm of x for base e .
WP 34S Owner‘s Manual
Edition 2.2 Page 44 of 103
Name Keys to press
L n
… in modes Remarks
DECM
Laguerre's polynomials (compare L n
below):
L n
e x n !
d n dx n
x n e
x
L n
( 0 )
with n in solving the differential equation
x
y
"
1
x
y
'
ny
0
Y ,
.
LN1+x LN1+x DECM
Natural logarithm of values close to zero. Returns ln
1
x
, providing a much higher accuracy in the fractional part of the result.
L n
… DECM
Laguerre's generalized polynomials with n in and
in Z :
L n
(
) x
n !
e x
d dx n n
x n
e
x
Y
.
LN β
LN β
LN β
LN Γ
LN Γ
LN Γ
LOAD …
LOG
10
LOG
2
DECM
Returns the natural logarithm of Euler‘s β function. See there.
DECM Returns the natural logarithm of Γ( x ) . See there.
LogF …
Logis
Logis
P
…
Logis
–1
\
Restore the entire backup. Compare SAVE.
DECM Returns the logarithm of x for base 10.
\
Returns the logarithm of x for base 2.
DECM
Selects the logarithmic curve fit model y
a
0
a
1 ln x .
DECM
Logistic distribution with μ given in J and s in K .
Logis
P
returns
Logis returns f
Lg
F
Lg
e
x
s
1
e
x
s s
1
e
x
s
1
.
2
,
Logis
–1
returns F
1
Lg
s
ln
1
p p
for a probability p given in X , μ in J , and s in K .
WP 34S Owner‘s Manual
Edition 2.2 Page 45 of 103
Name Keys to press in modes Remarks
DECM Returns the logarithm of y for base x .
LOGx
MIRROR
…
DECM
Returns the complex logarithm of z + i t for the complex base x + i y .
LZOFF
LZON
…
Toggles leading zeros like flag 3 does in
HP-16C . Relevant in integer modes only.
L.R.
M - O
MANT …
MASKL
MASKR
MASKL n etc.
DECM
DECM
Returns the parameters a
1
and a
0 of the fit curve through the data points accumulated, according to the model selected, and pushes them on the stack. For a straight regression line, a
0
is the yintercept and a
1
the slope.
Returns the mantissa m of the number displayed
. Compare EXPT.
Integer
Work like MASKL and MASKR on HP-16C , but with the mask length following the command instead of taken from X .
MAX
…
MIN
\
\
Returns the maximum (minimum) of x and y .
Integer
Reflects the bit pattern in x
(e.g. 000101 becomes 101000 for word size 6).
MONTH
MROW+×
MROW×
MROW
MSG
…
…
…
…
MSG n
DECM
Assumes x containing a date in the format selected and extracts the month.
DECM
Takes a matrix descriptor in X , a destination row number in Y , a source row number in Z , and a real number in T . It multiples each element m zi by t and adds it to m yi
. The stack is unchanged.
M.ROW+× is similar to PPC M3 .
DECM
Takes a matrix descriptor in X , a row number in
Y , and a real number in Z . It multiples each element m yi
by z . The stack is unchanged.
M.ROW× is similar to PPC M2 .
DECM
Takes a matrix descriptor in X and two row numbers in Y and Z . It swaps the contents of rows y and z . The stack is unchanged. M.ROW
is similar to PPC M1 .
PRG
Throws the error message specified. It will vanish with the next keystroke. See below for the respective error codes. Compare ERR.
WP 34S Owner‘s Manual
Edition 2.2 Page 46 of 103
Name Keys to press
M+× …
M
-1 …
M-ALL
M-COL
M-DIAG
M-ROW
…
…
…
…
M× … in modes Remarks
DECM
Takes two matrix descriptor s in X and Y , and a real number z . Returns .
Thus a scalar multiple of one matrix is added to another matrix. The multiply adds are done internally in high precision and results should be exactly rounded.
DECM
Takes a descriptor of a square matrix in X and inverts the matrix in-situ. Doesn't alter the stack.
DECM
Takes a matrix descriptor in X , saves it in L , and returns a value suitable for ISG or DSL looping in X . The loop processes all elements in the matrix. The loop index is DSL if the descriptor is negative and ISG else.
DECM
Takes a matrix descriptor in X and a column number in Y . Returns a loop counter in X , dropping the stack. The matrix descriptor is saved in
L . The loop processes all elements m iy
only. The loop index is DSL if the descriptor is negative and ISG else.
DECM
Takes a matrix descriptor in X , saves it in L , and returns a loop counter in X . The loop processes all elements along the matrix diagonal, i.e. all elements m ii
. The loop index is DSL if the descriptor is negative and ISG else.
DECM
Takes a matrix descriptor in X and a row number in Y . Returns a loop counter in X , dropping the stack and setting last L like all two-argument commands. The loop processes all elements m yi only. The loop index is DSL if the descriptor is negative and ISG else.
DECM
Takes two matrix descriptor s in Y and Z and the integer part of x as the base address of the result. Returns . The fractional part of x is updated to match the resulting matrix – no overlap checking is performed.
All calculations are done internally in high precision, although it would still be possible to trick the code up and produce bad results. It would be very difficult to get the same degree of accuracy in RPN since the best that can easily be achieved there is a·b+c·d and a matrix multiply adds more terms than this.
WP 34S Owner‘s Manual
Edition 2.2 Page 47 of 103
Name Keys to press
M.COPY
M.DY
M.IJ
M.LU
M.REG
…
…
…
…
…
M.SQR? …
NAND …
NaN? … nBITS … nCOL …
NEXTP …
NOP …
NOR … in modes Remarks
DECM
\
Takes a matrix descriptor in Y and a register number in X . Copies the matrix into registers starting at X . Returns a properly formed matrix descriptor in X .
Sets the format for date display.
DECM
Takes a matrix descriptor in X and a register number in Y . Returns the column that register represents in Y and the row in X . The descriptor is saved in L . M.IJ is similar to PPC M4 .
DECM
Takes descriptor of a square matrix in X . Transforms the matrix into its LU decomposition. The matrix is modified in-situ. The value in X is replaced by a pivot descriptor that defines the pivots that were required to calculate the decomposition. The most significant digit is the pivot for the first diagonal entry, the next most the second and so forth.
DECM
Takes a matrix descriptor in X , a row number in
Y , and a column number in Z . The descriptor is saved in L . M.REG returns the register number in X (popping the stack twice). It is similar to
PPC M5 .
\
\
DECM
Takes a matrix descriptor in X and tests it. Returns ―true‖ if the matrix is square.
Works in analogy to AND.
Tests x for being ―Not a Number‖.
Integer Counts bits set in x like #B does on HP-16C .
DECM
Takes a matrix descriptor in X , saves it in L , and returns the number of columns in this matrix.
\
Returns the next prime number > x .
PRG ―Empty‖ step FWIW.
\
Works in analogy to AND.
WP 34S Owner‘s Manual
Edition 2.2 Page 48 of 103
Name Keys to press
Norml
…
Norml
P
Norml
–1 …
NOT nROW …
OR
P - R n …
ODD? …
OFF
PERM
P n
… in modes Remarks
DECM
Normal distribution with an arbitrary mean µ specified in J and standard deviation σ in K :
Norml
P
20
returns f
N
1
2
e
x
2
2
2
,
Norml returns F
N
x
. See below for the standard normal distribution
Φ
.
DECM
Returns x for a given probability F
N
in X , mean µ in J , and standard deviation σ in K 21
.
Integer Works in analogy to AND.
DECM
Takes a matrix descriptor in X , saves it in L , and returns the number of rows in this matrix.
DECM
Recalls the number of accumulated data points.
Necessary for basic statistics.
\
Checks if x is integer and odd.
PRG
Inserts a step to turn your WP 34S off under program control.
\
DECM
Works in analogy to AND.
Returns the number of possible arrangements of y items taken x at a time. No item occurs more than once in an arrangement, and different orders of the same x items are counted separately.
Formula: P y , x
x !
C y , x
, compare COMB.
DECM
Legendre's polynomials:
P n
2 n
1 n !
d dx n n
x 2
1
n
with n in Y , solving the differential equation d dx
1
x
2
d dx f
n
n
1
0 .
20
Norml
P
corresponds to NORMDIST( x; µ ;
σ;
0 ) and Norml to NORMDIST( x; µ ;
σ;
1 ) in MS Excel.
21
This corresponds to NORMINV( F
N
; µ ;
σ
) in MS Excel.
WP 34S Owner‘s Manual
Edition 2.2 Page 49 of 103
Name
Poiss
Poiss
P
…
Poiss
– 1
Keys to press
PowerF … in modes Remarks
DECM
Poisson distribution with the number of successes g in X , the gross error probability p
0
in J , and the sample size n in son ‘s
n
p
0
K . Alternatively, Poismay be in J if k = 1:
Poiss
P
22
returns P
P
( g ;
)
g e
g !
,
Poiss returns F
P
( m ;
)
g m
0
P
P
( g ;
) , with the maximum number of successes m in X .
Poiss
– 1
returns m for given probabilities F
P in X and p in J with sample size n in K .
DECM Selects the power curve fit model y
a
0 x a
1 .
PRCL
PRIME?
PROFRC
PRCL
… n \
\
Recall the user program space from flash segment n to RAM where it may be edited then (see above ).
Checks if the absolute value of the integer part of x is a prime. The method is believed to work for integers up to 9E18.
DECM
Sets fraction mode like in HP-35S , allowing only proper fractions or mixed numbers in display.
Converts x according to the settings by DEN…
Absolute decimal equivalents of x must not exceed 100,000. Compare IMPFRC.
PROMPT …
FRC
Allows displaying only proper fractions. Thus converts an improper fraction in X , if applicable, e.g. 5/3 into 1 2/3.
PRG
Displays
(equaling alpha and stops program execution
VIEW followed by STOP actually).
See below for more.
PSE nn
PSTO PSTO n \
PRG
Refreshes the display and pauses program execution for nn ticks, with . The pause will be terminated early as soon as a key is pressed.
Stores the user program space in flash segment n (see above ).
22
The pmf corresponds to POISSON( g;
; 0 ) and the cdf to POISSON( g;
; 1 ) in MS Excel.
WP 34S Owner‘s Manual
Edition 2.2 Page 50 of 103
Name Keys to press in modes Remarks
PUTK
RAD
P
P
n \
PUTK a All
Assumes a key code in address a . Stops program execution, takes said code and puts it in the keyboard buffer resulting in immediate execution of the corresponding call. quired to resume program execution.
is re-
May help in user interaction with programs.
Exchanges the user program space with the contents of flash segment n (see above ).
DECM Sets angular mode to radians.
RAD
DECM
Returns a random number between 0 and 1 like
RAN in HP-42S .
RAN#
Integer Returns a random bit pattern for the word size set.
RCF s
RCF
RCF s
\
Works like RCL but recalls from a register in flash memory. Also the six recall arithmetic operations may be performed like with RCL.
RCF.RG
RCF.ST
RCL
…
…
\
\
Recovers all general purpose registers from the backup region (see SAVE and above ).
Recovers the system state from the backup region (see SAVE and above ).
See the addressing table above for
C
RCL.
RCLM
\
s
RCLM s
\
Recalls mode settings stored via STOM as described above .
RCLS
… DECM
Takes x as radians and converts them to the angular mode currently set.
RCLS s \
Recalls 4 or 8 values from a set of registers starting at address s , and pushes them on the stack. This is the converse command of STOS.
RCL+
RCL –
RCL×
RCL/
s s s s
\
Recalls the content of address s , executes the specified operation on it and pushes the result on the stack.
E.g. RCL –12 subtracts r12 from x and displays the result (acting like 12 , but without losing a stack level). In analogy,
C
RCL –12 subtracts r12 from x and r13 from y .
See the addressing table above for
C
RCL.
WP 34S Owner‘s Manual
Edition 2.2 Page 51 of 103
Name Keys to press
RCL
RCL
RDX,
s
s
RDX ,
RDX ,
RDX.
RDX .
RDX .
REALM? … in modes Remarks
\
\
\
RCL ( ) recalls the maximum (minimum) of the values in s and X .
Sets the decimal mark to a comma.
Toggles the radix mark.
Sets the decimal mark to a point.
RECV
RESET
…
…
RJ …
RL RL n
RLC RLC n
\
\
All
Tests if your WP 34S is in real mode.
Prepares your WP 34S for receiving data via serial I/O. See Appendix A for more.
Executes CLALL and resets all modes to startup default, i.e. 24h, 2COMPL, ALL 00, DEG,
DENANY, DENMAX 9999, DECM, LinF,
PROFRC, RDX .
, SCIOVR, SSIZE4, WSIZE 64,
Y.MD. See these commands for more information. RESET is not programmable.
Integer Right adjusts, in analogy to LJ on HP-16C .
Integer
Works like n consecutive RLs / RLCs on
HP-16C . For RL, 1 ≤ n ≤ 63. For RLC, 1 ≤ n ≤
64. RL 0 and RLC 0 execute as NOP.
RM
RM?
RMDR
…
…
\
\
\
Sets the floating point rounding mode. This is for numerical mathematics geeks only, since it is only used when converting from the high precision internal format to packed real numbers. It will not alter the display nor change the behavior of ROUND. The following modes are supported:
0: round half even: ½ = 0.5 rounds to next even number (default).
1: round half up: 0.5 rounds up.
2: round half down: 0.5 rounds down.
3: round up:
4: round down:
5: ceiling:
6: floor: away from 0. towards 0 (truncates). rounds towards
+∞
. rounds towards
–∞
.
Returns the floating point rounding mode set.
See RM for more.
Equals RMD on HP-16C .
WP 34S Owner‘s Manual
Edition 2.2 Page 52 of 103
Name
ROUND
Keys to press
ROUNDI …
RR RR n
RRC RRC n in modes Remarks
DECM
Rounds x using the current display format, like
RND in HP-42S .
FRC
Rounds x using the current denominator, like
RND in HP-35S fraction mode.
DECM Rounds x to next integer. ½ rounds to 1.
Integer
Works like n consecutive RRs / RRCs on
HP-16C . See RL / RLC for more.
RTN
RTN+1
R.CLR
R.COPY
R.SORT
…
…
…
…
\PRG Moves the program pointer to step 000.
PRG
Last command in a routine. Returns control to the calling routine in program execution, i.e. moves the program pointer one step behind the most recent XEQ instruction encountered. If there is none, program execution halts and the program pointer is set to step 000.
PRG
Returns control to the calling routine like RTN, but moves the program pointer to the second line following the most recent XEQ instruction encountered. If there is none, program execution halts.
DECM
DECM
Interprets x in the form ss.nn
. Clears nn registers starting with number ss .
E.g. for x = 34.56, R-CLR will clear R34 through
R89 .
Interprets x in the form ss.nndd
. Takes nn registers starting with number ss and copies their contents to dd etc.
E.g. for x = 7.0345678, r07, r08, r09 will be copied into R45, R46, R47 , respectively.
For x < 0 , R-COPY will take nn registers from flash memory instead, starting with register number | ss | there.
DECM
Interprets x in the form ss.nn
. Sorts the contents of nn registers starting with number ss .
Assume x = 49.036 , r49 = 1.2 , r50 = –3.4 , and r51 = 0 ; then R-SORT will return r49 = -3.4 , r50 = 0 , and r51 = 1.2.
WP 34S Owner‘s Manual
Edition 2.2 Page 53 of 103
Name Keys to press in modes Remarks
R.SWAP
R D
… DECM
Works like R-COPY but swaps the contents of source and destination registers.
DECM
Please see the catalog of conversions below for conversions of radians to degrees.
R
R
S - U s
\
DECM
Rotates the stack contents one level up or down, respectively. See above for details.
Takes the statistical sums accumulated, calculates the sample standard deviations s y
and s x and pushes them on the stack.
SAVE … \
Saves user program space, registers and system state to flash memory. Program space is stored in segment 0. Registers and system state are in their own special region.
SCI
SB SB n
n
SCIOVR \
Integer Sets the specified bit in x .
\
Sets scientific display format.
Numbers exceeding the range displayable in
ALL or FIX will be shown in scientific format (default as in vintage HP calculators). Compare
ENGOVR.
SDL SDL n DECM
Shifts digits left by n decimals, equivalent to multiplying x by 10 n
.
SDR SDR n DECM
Shifts digits right by n decimals, equivalent to dividing x through 10 n
.
SEED
SENDA
SENDP
…
…
…
DECM Stores a seed for random number generation.
\
Sends all RAM data …
SENDL
SENDL n
\
\
Sends the library file of region n into RAM …
Sends the user program memory …
… via serial I/O to the device connected. See
Appendix A below for more.
SENDR … \
Sends the general purpose registers 00 to 99 …
SERR … DECM
Works like s but pushes the standard errors s n on the stack (i.e. the standard deviations of x and ).
WP 34S Owner‘s Manual
Edition 2.2 Page 54 of 103
Name Keys to press in modes Remarks
SERRw … DECM
Works like sw but returns the standard error s
y i
(i.e. the standard deviation of x w
).
SETCHN
SETDAT
…
…
\
DECM
Sets some regional preferences (see above ).
Sets the date for the real time clock (doesn‘t work with the emulator, since the emulator takes this information from the PC clock).
SETEUR
…
SETIND
\
Set some regional preferences (see above ).
SETTIM …
Sets the time for the real time clock (doesn‘t work with the emulator, since the emulator takes this information from the PC clock).
SETUK
SETUSA
… \
SF SF n \
SHOW
SIGN
…
…
Set some regional preferences (see above ).
Sets the flag specified.
DECM &
\PRG
Shows the full mantissa until the next key is pressed. See above .
\
PRG
Displays a CRC checksum of program memory contents, allowing validation of program integrity.
Not programmable.
Returns 1 for x > 0, –1 for x < 0, and 0 for x = 0 or non-numbers.
SIGNMT …
DECM Returns the unit vector of x + i y in X and Y .
\
Sets sign-and-mantissa mode for integers.
SIN
DECM
DECM Returns the sine of the angle in X .
SINC …
SINH
SKIP SKIP n
DECM Returns sin x
.
DECM Returns the hyperbolic sine of x .
PRG
Skips n program steps forwards (1 ≤ n ≤ 99). So e.g. SKIP 02 skips over the next two steps, going e.g. from step 123 to step 126. If the skip would land beyond the end of occupied program memory, the same will happen as if a RTN had been encountered.
WP 34S Owner‘s Manual
Edition 2.2 Page 55 of 103
Name
SL
SLOW
Keys to press
SL n
… in modes Remarks
Integer
All
Works like n (up to 63) consecutive SLs on
HP-16C . SL 0 executes as NOP.
Sets the processor speed to ―slow‖. This is also entered for low battery voltage.
SLV
SLVQ
SMODE?
SPEC?
label
…
…
…
DECM
DECM
\
Solves the equation f( x ) = 0 , with f( x ) calculated by the routine specified. Two initial estimates of the root must be supplied in X and Y when calling SLV. For the rest, the user interface is as in HP-15C . This also means SLV acts as a test, so the next program step will be skipped if
SLV failed to find a root.
Solves the quadratic equation ax 2
bx
c
0 , with the real parameters put on the stack
[ c, b, a , …] , and tests the result.
If r :
b
2
4 ac
0 , SLVQ returns
b
r
2 a in Y and X . In a program, the step after
SLVQ will be executed.
Else, SLVQ returns the real part of the first complex root in X and its imaginary part in Y
(the 2 nd
root is the conjugate of the first – see
CONJ). If run directly from the keyboard, the complex indicator is lit then – in a program, the step after SLVQ is skipped.
In either case, r is returned in Z . Higher stack levels are kept unchanged. L contains c .
Returns the integer sign mode set, i.e.
2 (meaning ―true‖) for 2‘s complement,
1 (―true‖ again) for 1‘s complement,
0 (i.e. ―false‖) for unsigned, or
1 (i.e. ―true‖) for sign and mantissa mode.
\
True if x is special, i.e. infinity or NaN.
SR SR n Integer
Works like n consecutive SRs on HP-16C . SR 0 executes as NOP.
SSIZE4
SSIZE8
…
SSIZE? …
\
\
Sets the stack size to 4 or 8 levels, respectively.
See above . The same will happen if stack size is changed via RCLM.
STATUS \PRG
Returns the number of stack levels accessible.
Shows the status of all user flags, similar to
STATUS on HP-16C . See above .
WP 34S Owner‘s Manual
Edition 2.2 Page 56 of 103
Name
STO
STOM
STOP
Keys to press in modes Remarks
d \
s
STOM s
\
See the addressing table above for
C
STO.
Stores mode settings for later use as described above . Take RCLM to recall them.
PRG
Stops program execution. May be used to wait for an input, for example.
STOS
STOS d
\
Stores all stack levels in a set of 4 or 8 registers, starting at destination d .
STO+
STO –
STO×
d
d d
\
Executes the specified operation on the content of address d and stores the result into said address.
E.g. STO –12 subtracts x from r12 like the sequence 12 12 does, but without touching the stack at all.
See the addressing table above for
C
STO.
STO/
STO
STO
d
d
d
\
STO ( ) takes the maximum (minimum) of the values in d and X and stores it.
SUM … DECM
Recalls the linear sums Σy and Σx . Useful for elementary vector algebra in 2D. sw … DECM
Returns the standard deviation for weighted data s w
y i
y i y i
x i
2
2
y i
2
y i
x i
2
with the weights entered in y via +.
TAN
TANH sxy …
DECM
Returns the sample covariance for two data sets.
It depends on the fit model selected. For LinF, it returns s xy
n
x i n y i
(
n
1 x
) i
y i
.
See COV for the population covariance.
DECM Returns the tangent of the angle in X .
DECM Returns the hyperbolic tangent of x .
WP 34S Owner‘s Manual
Edition 2.2 Page 57 of 103
Name Keys to press
TICKS …
TIME …
T n
…
TOP? …
TRANSP …
t
P
(x) t(x) … t
– 1
(p)
U n
…
V - Z
UNSIGN
VERS
…
…
VIEW s
VW
+ s
W … in modes Remarks
\
Returns the number of ticks from the real time clock at execution time. With the quartz built in,
1 tick = 0.1 s. Without, it may be 10% more or less. So the quartz is inevitable prerequisite for the clock being useful in medium to long range.
DECM,
Recalls the time from the real time clock at execution, displaying it in the format hh.mmssdd
in
24h-mode. Chose FIX 6 for best results.
DECM
Chebychev's (a. k. a. Čebyšev, Tschebyschow,
Tschebyscheff) polynomials of first kind T n
( x ) with n in Y , solving the differential equation
1
x
2
y "
x
y '
n
2 y
0 .
PRG
Executes the next step only if it is called from a program that isn't a subroutine, i.e. if the program running flag is set and the return stack pointer points to an empty stack.
DECM
Takes a matrix descriptor in X and returns the descriptor of its transpose. The transpose is done in-situ and does not require any additional registers or storage.
DECM
Student‘s t distribution. t(x) equals 1 – Q(t) in
HP-21S . The degrees of freedom are stored in J . t
P
(x) denotes the respective pdf .
DECM
Chebychev's polynomials of second kind U n
( x ) with n in Y , solving the differential equation
1
x
2
y "
3 x
y '
n
n
2
y
0 .
\
\PRG
\
Sets unsigned mode for integers.
Shows your firmware version and build number.
Displays the content of address s until the next key is pressed. See below for more.
Displays the alpha register in the top line plus the contents of address s in the bottom line until the next key is pressed. See below for more.
DECM R eturns Lambert‘s W for given x ≥ –1/e .
WP 34S Owner‘s Manual
Edition 2.2 Page 58 of 103
Name Keys to press in modes Remarks
WDAY
W
– 1
Weibl
Weibl
P
Weibl
– 1
…
…
…
DECM
Takes x as a date in the format selected and returns the name of the day in the dot matrix and a corresponding integer in the numeric display
(Monday = 1, Sunday = 7).
DECM Returns x for given W ( ≥ -1). See W above.
DECM
Weibull distribution with the shape parameter b in J and the characteristic lifetime T in K :
Weibl
P
23
returns f
W
( t )
b
T
Weibl returns F
W
( t )
1
e
t
T t
T b
. b
1 e
T t b
,
Weibl
–1
returns the survival time t s for given probability F
W
, b in J and T in K .
WSIZE
WSIZE n
\
Works like on HP-16C , but with the parameter following the command instead of taken from X .
Reducing the word size truncates the values in the stack registers employed, including L .
WSIZE 0 sets the word size to maximum, i.e. 64 bits.
WSIZE? … x
2
XEQ
\
\
Recalls the word size set.
PRG Calls the respective subroutine.
label
\PRG, \
Executes the respective program.
, , , or
PRG
Calls the respective subroutine, so e.g. XEQ C will be inserted when is pressed.
(you may need for reaching these hotkeys in integer bases >10.)
\PRG, \
Executes the respective program if defined.
XEQ
… \
Takes the first three characters of alpha (or less if there are less) as a label and calls or executes the respective routine.
XNOR
XOR
…
\
\
Works in analogy to AND.
Works in analogy to AND.
23
The pdf equals WEIBULL( x ; b; T; 0 ) and the cdf WEIBULL( x; b; T; 1 ) in MS Excel.
WP 34S Owner‘s Manual
Edition 2.2 Page 59 of 103
Name x !
x …
x
x x
y
Keys to press
x g … x w …
r
x < … ? x < ?
a x ≤ … ? x ≤ ?
a x = … ? a x = +0 ? x=+0?
x = –0 ? x= –0?
x ≈ … ? x ≈ ?
a x ≠ … ? a x ≥ … ? x ≥ ?
a x > … ? x > ?
a in modes Remarks
DECM
Returns the arithmetic means, pushing y
1 n
y and x
1 also s, SERR, and n
.
x on the stack. See
DECM
Returns the geometric means, pushing y g
n
y
e
1 n
ln y
and x g stack. See also
,
m
, and
P
.
n
x on the
\
DECM
Returns the weighted arithmetic mean
xy
y
. See also sw and SERRw.
DECM
Returns a forecast x for a given y (in X ) following the fit model chosen. See L.R. for more.
DECM Return the factorial, equaling Γ( x + 1) .
Interprets x as character code. Appends the respective character to alpha , similar to XTOA in
HP-42S .
\
\
Swaps the contents of X and r , in analogy to x y .
Swaps x and y , performing Re Im if a complex operation was executed immediately before. See above for details.
\
Compare x with a . E.g. x < ?
will compare x with the contents of register K , and will be listed as in a program. See the examples given in the addressing table above for more. x ≈ ? will be true if the rounded values of x and a are equal (see ROUND).
a and a compare the complex number x + i y as explained in the addressing table above .
The signed tests x = +0 ? and x = –0 ? are meant for integer modes 1COMPL and SIGNMT, and for DECM if flag D is set. Then, e.g. 0 divided by -7 will display -0.
WP 34S Owner‘s Manual
Edition 2.2 Page 60 of 103
Name Keys to press in modes Remarks y x
YEAR …
DECM
Assumes x containing a date in the format selected and extracts the year.
\
In integer modes x must be ≥ 0.
\
& \(13,
14, 15, h)
Shortcut working as long as label C is not defined yet. ŷ DECM
Returns a forecast y (in X ) for a given x following the fit model chosen. See L.R. for more.
\
Sets the format for date display. y z
-
Y.MD …
DATE
DAY
r r
GTO
GTO nn
IP
…
\
\integer
Swaps the contents of Y or Z and r , in analogy to x
.
Takes x as a date and appends it to alpha in the format set. See DATE. – To append a date stamp to alpha , call DATE
DATE.
\integer
Takes x as a date, recalls the name of the respective day and appends its first 3 letters to alpha .
\
All
Takes the contents of R nn as character code.
Takes the first three characters of the converted code (or less if there is only less) as an alpha label and positions the program pointer to it.
Appends the integer part of x to alpha , similar to
AIP in HP-42S .
LENG
All
Returns the number of characters found in alpha , like ALENG in HP-42S .
MONTH … \integer
Takes x as a date, recalls the name of the respective month and appends its first 3 letters to alpha .
OFF
ON
RCL
s
RCL s \
PRG &
PRG
&
\
Work like AOFF and AON in HP-42S , turning alpha mode off and on.
Interprets the content of the source s as characters and appends them to alpha .
WP 34S Owner‘s Manual
Edition 2.2 Page 61 of 103
Name Keys to press in modes Remarks
RC#
RL
RR
SL
SR
RC# s All
RL n All
RR n All
SL n All
SR n All
Takes the content of s as a number, converts it to a string in the format set, and appends this to alpha . If e.g. s = 1234 and ENG 2 and RDX .
are set, then
␣
1.23E3 will be appended.
Rotates alpha by n characters like AROT in HP-
42S , but with n ≥ 0 and the parameter trailing the command instead of taken from X .
RL 0 executes as NOP.
Works like
RL but rotates to the right.
Shifts the n leftmost characters out of alpha , like
ASHF in HP-42S .
SL 0 equals NOP.
Works like
SL but takes the n rightmost characters instead.
Stores the first (i.e. leftmost) 6 characters in the alpha register into destination d .
STO
TIME
d
STO d \
\integer
Takes x as a decimal time and appends it to alpha in the format hh:mm:ss according to the time mode selected. See TIME. – To append a time stamp to alpha , call TIME
TIME.
VIEW
All
Displays alpha in the top line and - - - in the bottom line until the next key is pressed. See below for more.
XEQ
XEQ nn
\
Takes the contents of R nn as character code.
Interprets the first three characters (or less if there are only less) of the converted code as an alpha label and calls or executes the respective routine.
x
DECM
Returns the character code of the leftmost character in alpha and deletes this character, like
ATOX in HP-42S .
Returns Euler‘s Beta
Re
0 , Re
0
B x , y
x
x
y y
with
. Called
here for avoiding ambiguities.
WP 34S Owner‘s Manual
Edition 2.2 Page 62 of 103
Name Keys to press
Γ
Γ
Γ
ΓDAYS …
Δ%
π
Π
m
m
p
p
δ δ
label in modes Remarks
DECM Returns
Γ( x ) .
Additionally, calls
x
1
.
DECM
Assumes X and Y containing dates in the format chosen and calculates the number of days between them. Works like in HP-12C .
DECM Returns 100
x
y y
like %CH in HP-42S .
DECM
DECM
Calculates the scattering factors (or geometric standard deviations) for lognormally distributed data ln(
y
)
ln
2
n
2 n
1
ln
G
and ln(
x
) and pushes them on the stack. This
works for the geometric mean x g in analogy to s for the arithmetic mean x but multiplicative.
Works like
but pushes the scattering factors of
1 the geometric means
m
n on the stack.
DECM
Works like
but with a denominator n instead of n – 1 , returning the scattering factors of the populations. – Streichkandidaten. Zusatzabschnitt über lognv Daten vorne einfügen.
DECM
Returns Riemann‘s Zeta function for real arguments, with
n
1 n
1 x
for x > 1 and its analytical continuation for x < 1 :
2 x
x
1 sin
2 x
1
x
1
x
.
DECM Complex version copies
in X and clears Y .
DECM
Computes a product with the routine specified by label . Initially, X contains the loop control number in the format cccccc.fffii
and the product is set to 1. Each run through the routine specified computes a factor. At its end, this factor is multiplied with said product; the operation then decrements ccccccc by ii and runs said routine again if then ccccccc ≥ fff , else returns the resulting product in X .
WP 34S Owner‘s Manual
Edition 2.2 Page 63 of 103
Name
- the End
Keys to press
Σ label in modes Remarks
DECM
Computes a sum with the routine specified by label . Initially, X contains the loop control number in the format cccccc.fffii
and the sum is set to 0. Each run through the routine specified computes a summand. At its end, this summand is added to said sum; the operation then decrements ccccccc by ii and runs said routine again if then ccccccc ≥ fff , else returns the resulting sum in X .
DECM
Works like s but returns the standard deviations of the populations instead.
ln 2 x
ln 2 y
lnx
lnxy …
lny
xlny
ylnx
DECM
Recall the respective statistical sums. These sums are necessary for curve fitting models beyond pure linear. Calling them by name enhances readability of programs significantly.
w
DECM
Works like sw but returns the standard deviation of the population instead.
w
y i
x i
y
i x w
2
Σ+
x
x 2
x 2 y
xy
…
y
y 2
Σ–
θ
(x) …
DECM
Recall the respective statistical sums. These sums are necessary for basic statistics and linear curve fitting. Calling them by name enhances readability of programs significantly.
DECM Adds a data point to the statistical sums.
DECM Shortcut as long as label A is not defined yet.
DECM Subtracts a data point from the statistical sums.
DECM Standard normal pdf :
1 x
2
2
e
2 .
WP 34S Owner‘s Manual
Edition 2.2 Page 64 of 103
Name
H.MS
Keys to press
in modes Remarks
Φ
(x) Φ
Φ –1
(p) Φ
2
2
INV
2 etc.
2
P
DECM
Standard normal cdf
z
dx , equals
1 – Q in HP-32E and 1 – Q(z) in HP-21S with z = x .
DECM
Chisquare distribution. The cdf
2
(with the degrees of freedom given in J ) equals 1 – Q( 2
) in
HP-21S .
+
–
×
/
+/ –
(-1)
X (-1)
X \
\
\
\
\
\
For x not being a natural number, this function will return cos
x
.
Returns y + x .
Returns y – x .
Returns y · x .
Returns y / x .
Unary minus like CHS in HP-35 .
DEG ( ) DECM
Takes x as an angle in the angular mode currently set and converts it to degrees. Prefix may be omitted.
GRAD ( ) DECM Like DEG, but converts to gon or grads.
H DECM
Takes x as hours or degrees in the format hhhh.mmssdd
and converts them into a decimal time or angle.
DECM
Takes x as decimal hours or degrees and converts them into hhhh.mmssdd
as in vintage
HPs. For calculations, use H.MS+ or H.MS
– then or reconvert to decimal values before.
POL
RAD
REC
( )
DECM
Assumes X and Y containing 2D Cartesian coordinates ( x , y ) of a point and converts them to the respective polar coordinates ( r ,
) with the radius r
x
2
y
2
DECM Works like DEG, but converts to radians.
DECM
Assumes nates ( r ,
X and Y containing 2D polar coordi-
) of a point and converts them to the respective Cartesian coordinates ( x , y ) .
WP 34S Owner‘s Manual
Edition 2.2 Page 65 of 103
Name
%
%MG
%T
Keys to press
MG
%MRR
MRR
T
%
in modes Remarks x
y
DECM Returns
100
, leaving Y unchanged.
DECM
Returns the margin
24
100
x
y
in % for a x price x and cost y , like %MU-Price in HP-17B .
DECM
Returns the mean rate of return in percent per period, i.e. 100
x y
1 z
1
with x = future value after z periods, y = present value.
For z = 1 , Γ% returns the same result easier.
DECM Returns
x
100 , interpreted as % of total. y
DECM
Returns 100
x x
.
√‾
%+MG
+MG
DECM
Calculates a sales price by adding a margin of x % to the cost y , as %MU-Price does in y
HP-17B . Formula:
1
x
100
\
\
, \14,
\15, \h
Shortcut working as long as label D is not defined yet.
∫
| |
label
∞
? …
DECM
Integrates the function given in the routine specified. Lower and upper integration limits must be supplied in Y and X , respectively. Otherwise, the user interface is as in HP-15C .
\
Tests x for infinity.
DECM Returns
1 x
1 y
1
.
24 Margin corresponds to „Handelsspanne― in German.
WP 34S Owner‘s Manual
Edition 2.2 Page 66 of 103
Alphanumeric input:
(
)
+
– x
Character Keys to press
␣
°
0 … 9
A … F
A … Z
… in modes Remarks
Appends a blank space to alpha .
DECM
Separates degrees or hours from minutes and seconds, so input format is hhhh.mmssdd
.
The user has to take care where an arbitrary real number represents such an angle or time.
\
Standard numeric input. For integer bases <10, input of illegal digits is blocked. Please note you cannot enter more than 12 digits in the mantissa. in addressing
Register input. See the tables above for more.
, , ,
… ,
Appends the respective digit to alpha .
…
(grey print)
11, 12, 13,
14, 15, h
Numeric input for digits >10. See page 6 for more information. in addressing
Register input. See the addressing tables above for the letters applicable.
…
(grey print)
Appends the respective Latin letter to
Use to toggle cases. alpha .
EEX
DECM &
\FRACT
Works like in the Pioneers.
A … Ω
…
(grey print)
(
)
Appends the respective Greek letter to alpha .
will toggle cases. See page 7 for more.
Appends the respective symbol to alpha .
WP 34S Owner‘s Manual
Edition 2.2 Page 67 of 103
Character Keys to press
/
Second
\
|
£
¥
√
&
%
$
€
!
?
≠
±
,
.
‗ .
‘ or ‗ , ‘
(grey print)
(grey print)
(grey print)
(grey print)
(grey print)
in modes Remarks
DECM
A persistent 2 nd in input switches to fraction mode. It will be interpreted as explained below.
Please note you cannot enter after you entered twice – but you may delete the 2 nd
dot while editing the input line.
FRC
First is interpreted as a space, 2 nd
as a fraction mark. E.g. input of results in
2 ¾ in the display. Improper fractions may be entered starting with a , e.g. .
Appends a slash to alpha .
Appends the respective symbol to alpha .
DECM Inserts a radix mark as selected.
Appends the respective symbol to alpha .
WP 34S Owner‘s Manual
Edition 2.2 Page 68 of 103
Non-programmable Control, Clearing and Information Commands
Keys to press
25
/ 26 in modes Remarks
Input pending Deletes the last digit or character put in.
Deletes the rightmost character in alpha .
PRG Deletes current step.
Else Acts like CLx.
Status open Goes to previous / next set of flags.
Catalog open Goes to previous / next item in this catalog.
Scrolls the display window six characters to the left / right in alpha if possible. If less than six characters are beyond the limits of the display window on the left / right side, the window will be positioned to the beginning / end of string. Useful for longer strings.
/
DEL
P label
Else Acts like BST / SST in HP-42S .
Integer
Shifts the display window to the left / right like in
HP-16C . Helpful while working with small bases.
Toggles upper and lower case (indicated by
).
\
Enters a memory browser.
PRG
Deletes program steps from the current position downstream until, but excluding, the label specified.
If said label is not found, ―No such label‖ will be thrown.
If the program pointer is on the step containing said label, nothing will be deleted.
Catalog open Selects the current item like below.
Turns alpha mode off.
Else Acts like the command ENTER described above.
25
The mode conditions specified will be checked top down for this command:
If there is a pending input, the last digit / character entered will be deleted;
else if alpha mode is set, the last character of alpha will be deleted;
else if the WP 34S is in programming mode, the current step will be deleted;
else CLx will be called. Period.
This method holds for all commands listed here using this symbolic.
26
These two navigation keys will repeat with 5Hz when held down for longer than 0.5s.
WP 34S Owner‘s Manual
Edition 2.2 Page 69 of 103
Keys to press
in modes Remarks
Catalog open Leaves the catalog without executing anything.
Input pending
Cancels the execution of pending operations, returning to the calculator status as it was before.
Program running
Stops the running program like . See below.
PRG Leaves programming mode like . See below.
Turns alpha mode off like . See above.
Else Does nothing.
\PRG Turns calculator off.
Calculator off Turns calculator on.
Else
There are several -key combinations available. See below for more.
\
Toggles programming mode for keyboard entry.
Program running
Stops the program execution immediately. ―Stopped‖ will be shown in the upper row until the next keystroke.
\PRG & \
Runs the current program or resumes its execution starting with the current step.
Appends an ‗Y‘ to alpha .
PRG Acts like the command STOP described above.
Catalog open
Selects the item currently displayed and exits, executing the respective command. See below .
Else
\
Acts like the command XEQ described above.
Turns on alpha mode for keyboard entry. When entering alpha constants in programs, please note there is no concatenation character – added characters are appended to
CL alpha always. For starting a new string, use
first. Alpha constants will be listed like e.g. ‗Test 1‘.
WP 34S Owner‘s Manual
Edition 2.2 Page 70 of 103
CATALOGS
A catalog on your WP 34S is a collection of items, e.g. operations or characters. Opening a catalog will set alpha mode to allow for typing the first character(s) of the item wanted. A subset of the full alpha keyboard shown above is sufficient for browsing:
A
1/x Please note
will just call
B C D E F the character while browsing a f g h
G
H
I
catalog. (=
) eases operations in CONV .
ENTER
J
K
L
XEQ
M
N
O
P
▲
Q R
S
T
▼ 1 2
–
(
U V W
EXIT
0 ●
X
Y
+
Z
and browse the open catalog. or select the item shown, recall or execute it, and exit the catalog, while
will just leave it without executing anything, returning to the mode as set before.
See below for some examples.
WP 34S Owner‘s Manual
Edition 2.2 Page 71 of 103
Such catalogs may be called using the keystrokes listed below:
Keys to press
in modes Contents of said catalog
\
DECM
DECM
Predefined alpha labels. Some special rules apply here:
and browse the catalog as usual, but in the numeric line the location of the respective label is indicated (RAM,
Lib for XROM, or SEG n for flash memory segment n ).
– trigger a search starting in the flash segment specified (and continued in further segments as long as necessary) for the first alpha label defined.
goes to the alpha label as displayed, while or
execute it. These keystrokes will perform a label search as described above . Labels in XROM cannot be accessed by .
goes to the first alpha label in XROM.
or leave CAT returning to the state as it was before.
Constants like in HP35s. Picking a constant will recall it. See the constants listed in a table below .
This catalog contains the same constants as in real domain.
Picking one, however, does a complex recall here. So, if the stack did look like [ x , y , …] before calling CONST, it will contain [ constant , 0 , x , y , …] thereafter.
\
DECM Conversions as listed in a table below .
―Complex‖ letters mandatory for many languages. Case is determined by setting (see above).
Mode setting functions.
\
DECM Extra probability distributions.
Extra programming and I/O functions.
Subscripts.
Superscripts.
\
DECM Extra statistical functions.
All tests except the two on the keyboard.
Comparison symbols and brackets, except and .
WP 34S Owner‘s Manual
Edition 2.2 Page 72 of 103
Keys to press in modes Contents of said catalog
Integer Extra integer functions.
Extra alpha functions.
DECM Extra complex functions.
DECM Extra real functions.
These three catalogs are merged in mode PRG to ease programming.
Punctuation marks and text symbols.
Arrows and mathematical symbols.
Reopening the very last catalog called, the last command selected therein is displayed for easy repetitive use.
See the table below about addressing cataloged items , and the next pages for detailed item lists of the various catalogs. Within each catalog, items are sorted alphabetically
(see above for the sorting order). You may access particular items fast and easily by typing the first characters of their names. See below for some examples and constraints.
A single function, e.g. CB, may be contained in more than one catalog.
The alpha catalogs are found three pages below. See also the special catalogs CONST and CONV in separate paragraphs further below.
WP 34S Owner‘s Manual
Edition 2.2 Page 73 of 103
Catalog Contents in Detail:
12h Binom
1COMPL Binom
P
24h
BestF
COV
Binom
–1
ExpF
2COMPL Cauch LinF
BASE Cauch
P
LN
DENANY Cauch
–1 LNΓ
m
p
ln
ln
2
2 x y
DENFAC Expon LogF lnx
DENFIX Expon
P n lnxy
DENMAX Expon
–1
PowerF lny
DISP F
P
(x) SEED
w
D.MY F(x) SERR x
E3OFF F
–1
(p) SERRw x 2
E3ON Geom SUM x 2 y
FAST
LZON
Geom
P sw
FRACT Geom
–1 sxy
LZOFF Lgnrm x g
xlny
xy
y
y 2
M.DY
RDX,
RDX.
RM
Lgnrm
P x w
Lgnrm
–1 x
Logis
Logis
P
Γ
Logis
–1
ylnx
%
SETCHN Norml
SETEUR Norml
P
SETIND Norml
–1
SETUK Poiss
WSIZE?
SETUSA
SIGNMT Poiss
–1
SLOW t
Poiss
P
(x)
P
x < ?
x ≤ ?
x ≈ ?
x ≥ ?
SSIZE4 t(x)
SSIZE8 t
–1
(p)
UNSIGN Weibl
WSIZE
Y.MD
Weibl
θ(x)
P
Weibl
–1
WP 34S Owner‘s Manual
x > ?
∞
?
2
2
INV
2
P
Edition 2.2
BC?
BS?
ENTRY?
EVEN?
FC?
FC?C
FC?F
FC?S
FP?
FS?
FS?C
FS?F
FS?S
IBASE?
INTM?
BACK PSTO
CF PUTK
CLFLAG P
CLSTK RCF
DATE RCF.RG
DEC RCF.ST
DEL
P
RCLM
DSL RCLS
DSZ RDX,
ERR RDX.
RECV FF f ‘(x) f ‖(x)
GTO
RTN+1
R-CLR
R-COPY
H.MS+ R-SORT
INT?
KEY?
KTY?
LBL?
H.MS-
INC
ISE
ISZ
R-SWAP
SAVE
SENDA
SENDL
LEAP? LOAD SENDP
M.SQR? MROW+× SENDR
NaN?
ODD?
MROW× SF
MROW
SKIP
PRIME? MSG STOM
REALM? M-ALL STOS
RM? M-COL TICKS
SMODE? M-DIAG TIME
SPEC? M-ROW VW
+
SSIZE? M.IJ XEQ
TOP? M.REG
GTO nCOL
NOP
OFF
ON
PROMPT nROW
XEQ
PRCL
VIEW
Page 74 of 103
VERS
DATE
DAY
IP
LENG
MONTH
RC#
RL
RR
SL
SR
TIME
varies with the mode set, except in PRG. It contains in …
… alpha mode:
… decimal mode: … integer modes:
CLALL
CLREG
RESET
AGM
H n
LN
SLVQ
DATE ASR RCF
NEXTP (-1)
X
NOR
C
AGM
ANGLE LNΓ
BATT
B n
B n
*
CEIL
MANT
MAX
DAY
IP
LENG
MIN
MONTH
MONTH
RCL
CLALL M+×
CLREG M
-1
RC#
RL
CUBE M×
CUBERT M.COPY
RR
SL
DAY M.LU
SR
DAYS+ NAND
DECOMP NEXTP
STO
TIME
DEG NOR
BATT
CB
CLALL RL
CLFLAG RLC
CLREG RR
CUBE
CUBERT SB
DBLR
DBL*
DBL/
DROP
FB
FIB
RESET
RJ
RRC
SEED
SIGN
SL
SR
VERS
XNOR
C
CONJ
C
CUBE
C CU
B
E
RT
C DROP
C e x
-1
C
FIB
C
LN1+x
C
LN
C LNΓ
C
RCF
C
SIGN
C
SINC
C
W
DET
D J erf erfc
EXPT e x
-1
FIB
P n
DROP RAD
Γ
DAYS
RESET (-1)
X
FLOOR SETTIM % +MG NAND
GCD
RCF
ROUNDI % MG
SDL
SDR
% MRR MAX
SETDAT %
SIGN
δ
%
T
GCD
LCM
LJ
MASKL
XROOT
IP
C
W
–1
C
LENG
C Γ
RCL
C (-1) x
MASKR
MIN
MIRROR nBITS
RC#
RL
RR
SL
SR
STO
GRAD SINC
H np
I
IΓ
T n
TRANSP
U n
JG1582 VERS
JG1752 W
J D
LCM
WDAY
W
–1
LINEQS XNOR
L n x √y
LN1+x YEAR
L n
WP 34S Owner‘s Manual
Edition 2.2 Page 75 of 103
À
Á
à
á
Â Ã Ā Ă â ã ā ă
Ä ä (ă)
Here are the contents of the alpha catalogs making the WP 34S the most versatile global calculator known. Large font is printed in grey cells on this page. Accented letters show the same width as plain ones wherever possible.
Å å
Ć ć
Č
Ç č
ç
È è
É é
Ê Ē Ĕ Ě ê ē ĕ ě
Ë ë (ĕ)
ℏ
, : ;
‘ “
# * @ _
< ≤ = ≈ ≥ >
[ ] { }
Ì ì
Í í
(subscripts)
Î Ĩ Ī Ĭ î ĩ ī ĭ
0 1 2 A B c e k m n p u µ
Ï ï ( ĭ )
Ñ Ň ñ ň
~ ` ⊙ ⊕
∫ ∞
^
(superscripts)
∞ c
°
2 X -1
Ò
Ó
ò
ó
Ô Õ Ō Ŏ ô õ ō ŏ
Ö ö (ŏ)
Ø
Ř
Š
Ù
ø ř
š
ß
ù
The letters provided in your WP 34S allow for correct writing the languages of more than 3·10
9
people
(still only half of mankind yet), i.e.:
Afrikaans, Català, Cebuano, Česky, Cymraeg,
Deutsch, Eesti, English, Español, Euskara,
Français, Gaeilge, Galego, Greek, Bahasa Indonesia, Italiano, Basa Jawa, Kiswahili, Kreyòl ayisyen,
Magyar, Bahasa Melayu, Nederlands, Português,
Quechua, Shqip, Slovenčina, Slovenščina, Basa
Sunda, Suomeksi, Svenska, Tagalog, Winaray,
Zhōngwén (with a little trick explained below), and almost Dansk and Norsk (sorry, no æ) as well as
Hrvatski and Srpski (no Ď). If you know further living languages covered, please tell us.
Ú ú
Û Ũ Ū Ŭ û ũ ū ŭ
Ü
Ů
ü (ŭ) ů
Ý ý
Ÿ
Ž
ÿ ž
Mandarin Chinese (Zhōngwén) features four tones, usually transcribed like e.g. mā, má, mă, and mà. So you need different letters for ā and ă here, and for e, i, o, and u as well. With six pixels total character height we found no way to display these in both fonts nicely, keeping letters and accents separated for easy reading. For an unambiguous solution, we suggest using a dieresis (else not employed in Hànyŭ pīnyīn) representing the third tone here.
Pinyin writers, we ask for your understanding.
WP 34S Owner‘s Manual
Edition 2.2 Page 76 of 103
Addressing Catalog Items
1 User input
Dot matrix display
, , ,
, , ,
, or
, , or in alpha mode
,
S h o w s 1 s t
i t e m i n s e l e c t e d c a t a l o g .
, or in alpha mode
(e.g. in ) (e.g. Á in ) (e.g.
in )
Alpha mode is set.
2 User input
Dot matrix display
3 User input
Dot matrix display
4 User input
Dot matrix display
…
, , , , or 1 st
character
(e.g. )
Shows 1 st
item starting with this character *)
(e.g.
)
, , , , or 2 nd
character
(e.g. )
Shows 1 st
item starting with this sequence *)
(e.g. )
, , , , or character
(e.g. )
Shows 1 st
item starting with this letter *)
(e.g.
Ó )
, , , or
(e.g.
)
S h o w s n e x t i t e m i n t h i s c a t a l o g
(e.g.
) (e.g. Ò ) (e.g.
)
Continue browsing this way until reaching the item desired
(e.g.
). (e.g.
). (e.g.
). n User input
Dot matrix display
Calculator leaves the catalog returning to the mode set before
… and executes or inserts the command … and appends the selected character to alpha . chosen, or recalls the constant selected.
C o n t e n t s o f a l p h a r e g i s t e r
R e s u l t (e.g.
)
*) If a character or sequence specified is not found in this catalog then the first item following alphabetically will be shown. If there is no such item, then the last item in this catalog is displayed. You may key in even more than two characters – after 3 seconds, however, or after or , the search string will be reset and you may start with a first character again.
WP 34S Owner‘s Manual
Edition 2.2 Page 77 of 103
Constants
Below you find the contents of the catalog CONST. Navigation works as in the catalogs mentioned before. Names of astronomical and mathematical constants are printed on colored background below. Values of physical constants ( incl. their relative standard deviations given in parentheses below ) are from CODATA 2010, copied in July 2011, unless stated otherwise explicitly. Green background denotes exact or almost exact values. The more the color turns to red, the less precise the respective constant is known
27
.
For the units, remember Tesla with 1 T and on the other hand 1 J
1 W
s
1 V
1
Wb m
2
A
s
1
V m
2 s
1 eV e
, Joule with 1 J
6 .
24
10
6
TeV
1 N
m
1 kg
s
2 m
2
J
. Thus 1
T
1 A
m
2
.
Name Numeric value a 365.2425 (per definition)
Unit Remarks a
0
5.2917721092
E -11 (3.2
E -10) a m
384.4
E 6 a
⊕
1.495979
E 11 c 2.99792458
E 8 (per definition) c
1
3.74177153
E -16 (4.4
E -8) c
2
0.014387770
(1 E -3)
(1 E -6)
(9.1
E -7) d Gregorian year m Bohr radius
4
R
m m
Semimajor axis of the Moon‘s orbit around the Earth
Semimajor axis of the Earth‘s orbit around the sun. Within the uncertainty stated here, it equals 1 AU. m s
Vacuum speed of light m
2
W First radiation constant
2
h
c
2 m
K Second radiation constant
hc k e eE
1.602176565
E -19 (2.2
2.718281828459045…
E -8) C
1
Electron charge
2
K
J
R
K
0
G
0
Euler‘s e. Please note the letter e represents the electron charge elsewhere in this table.
F
F
F
96485.3365 (2.2
E -8)
2.5029078750958928...
4.6692016091029906...
C mol
Faraday‘s constant = e N
A
1
1
Feigenbaum‘s
Feigenbaum‘s g 9.80665 (per definition) m s
2
Standard earth acceleration
27
The bracketed values printed here for your kind attention allow you to compute the precision of results you may obtain using these constants. The procedure to be employed is called error propagation. It is often ignored, though essential for trustworthy results
– not only in science. Please turn to respective texts before you believe in 4 decimals of a calculation result based on yardstick measurements.
WP 34S Owner‘s Manual
Edition 2.2 Page 78 of 103
Name Numeric value
G 6.67384
E -11 h 6.62606957
E -34 (4.4
E -8) ℏ
1.054571726
E -34 (4.4
E -8) l p
1.616199
E -35 m e
9.10938291
E -31 (4.4
E -8)
M m
7.349
E 22 (5 E -4) m n
1.674927351
E -27 (4.4
E -8) m p
1.672621777
E -27 (4.4
E -8)
M p
2.17651
E -8
(1.2
E -4)
G o
7.7480917346
E -5 (3.2
E -10)
G c
0.915965594177… g e
2.00231930436153 (2.6
E -13)
GM 3.986004418
E 14 (2.0
E -9) k 1.3806488
E -23 (9.1
E -7)
j 4.83597870
E 14 (2.2
E -8)
(6.0
E -5)
(6.0
E -5) m u
1.660538921
E -27 (4.4
E -8) m u c
2
1.492 417 954 E -10 (4.4
E -8) m
µ
1.883531475
E -28 (5.1
E -8)
M
⊙
1.9891
E 30 (5 E -5)
M
⊕
5.9736
E 24 (5 E -5)
N
A
6.02214129
E 23 (4.4
E -8)
NaN p o
101325 (per definition) q p
1,8755459 E -18 (6.0
E -5)
Unit Remarks m
3 kg
s
2
Newton‘s gravitation constant. See GM below for a more precise value. m
1
Conductance quantum
2 e
2 h
2
R
K
3
1
1 s
2
Catalan‘s constant
( Landé‘s) electron g-factor
Newton‘s gravitation constant times the
Earth‘s mass with its atmosphere included
(according to WGS84, see Sa below).
J s Planck constant
h
2
J
K
Boltzmann constant
R
N
A
Hz
V
Josephson constant
2 e h m Planck length
G c
3
t p c kg
Electron mass
Mass of the Moon
Neutron mass
Proton mass
Planck mass
c
G
22
g
Atomic unit mass = 10
-3 kg / N
A
Atomic unit mass energy equivalent J kg
Muon mass
Mass of the sun
Mass of the Earth
1 mol
Avogadro‘s number
―not a number‖
Pa Standard atmospheric pressure
As
Planck charge
4
0
c
11 .
7 e . This was in CODATA 2006, but in 2010 no more.
WP 34S Owner‘s Manual
Edition 2.2 Page 79 of 103
Name Numeric value Unit Remarks
R 8.3144621 (9.1
E -7) r e
2.8179403267
E -15 (9.7
E -10)
R
K
25812.8074434
(3.2
E -10)
R m
1.737530
E 6 (5 E -7)
R 1.0973731568539
E 7 (5.0
E -12)
R
⊙
6.96
E 8
R
⊕
6.371010
E 6
(5 E -3)
(5 E -7)
Sa 6.3781370
E 6 (per definition)
Sb 6.3567523142
E 6 (1.6
E -11)
Se
2
6.69437999014
E -3 (1.5
E -12)
Se ’ 2
6.73949674228
E -3 (1.5
E -12)
Sf
-1
298.257223563 (per definition)
T o
273.15 (per definition) mol
J
K
Molar gas constant m Classical electron radius
2
a
0
Ω von Klitzing constant
h e
2 m Mean radius of the Moon
1 m
Rydberg constant
2 m e c
2 h m Mean radius of the sun m Mean radius of the Earth m
Semi-major axis of the model WGS84 used to define the Earth‘s surface for GPS and other surveying purposes ( http://earthinfo.nga.mil/GandG/publications/tr8350.2/tr8350_2.html
) m Semi-minor axis of WGS84
1
1
1
First eccentricity squared of WGS84
Second eccentricity squared of WGS84 (it is really called e‘ 2
in this article, I apologize)
Flattening parameter of WGS84
K = 0°C, standard temperature t p
5.39106
E -44
T p
1.416833
E 32
V m
0.022413968
Z o
376.730313461…
(6.0
E -5)
(6.0
E -5)
(9.1
E -7) s Planck time
G c 5
l p c
K Planck temperature
c 2 k
c
G
M p c
2 k
E p k m 3 mol
Molar volume of an ideal gas at standard conditions
RT
0 p
0
Charact. impedance of vacuum
0
0
0 c
7.2973525698
E -3 (3.2
E -10)
EM 0.57721566490153286…
p
2.675222005
E 8 (2.4
E -8)
1 Fine-structure constant
e
2
4
0
c
1
137
1 Euler-Mascheroni constant
1 s
T
Proton gyromagnetic ratio
2
P
WP 34S Owner‘s Manual
Edition 2.2 Page 80 of 103
Name Numeric value
o
8.854187817… E -12
c
2.4263102389
E -12 (6.5
E -10)
Unit Remarks
V
A
s m or
F m
Electric constant, vacuum permittivity
1
0 c
2
Compton wavelength of the electron
h m e c
cn
1.3195909068
E -15 (8.2
E -10)
cp
1.32140985623
E -15 (7.1
E -10) m
Compton wavelength of the neutron
h m n c
Compton wavelength of the proton
h m p c
µ o
1.2566370614… E -6
µ
B
9.27400968
E -24 (2.2
E -8)
µ e
-9.28476430
E -24 (2.2
E -8)
µ n
-9.6623647
E -27 (2.4
E -7)
µ p
1.410606743
E -26 (2.4
E -8)
µ u
5.05078353
E -27 (2.2
E -8)
µ
µ
-4.49044807
E -26 (3.4
E -8)
π 3.141592653589793…
B
5.670373
E -8
1.618033988749894…
o
2.067833758
E -15 (2.2
E -8)
7.292115
E -5
-
(3.6
E -6)
(2 E -8)
V
A
s m
Magnetic constant, also known as vacuum permeability
4
10
7
V
A
s m
(per definition)
Bohr‘s magneton e
2 m e
J
T or
A
m
2
Electron magnetic moment
Neutron magnetic moment
Proton magnetic moment
Nuclear magneton
e
2 m p
Muon magnetic moment
1
W m
2
K
4
2
5 k
4
Stefan Boltzmann constant
15 h 3 c 2
1
V s
Golden ratio
1
2
5
Magnetic flux quantum
h
2 e
1
K
J rad s
1
Angular velocity of the Earth according to
WGS84 (see Sa above)
Negative and positive infinity (may the Lord of
Mathematics forgive us calling these two ‗constants ‘)
WP 34S Owner‘s Manual
Edition 2.2 Page 81 of 103
Unit Conversions
Find below the contents of the catalog CONV
28
. Navigation works as in the other catalogs. There is one specialty, however: conversion displayed and leave CONV.
(i.e. ) will execute the inverse of the
Example: Assume the display set to FIX 3. Then keying in
will display and 1.619 below telling you 4 acres equal 1.619 hectares.
Now press and you will get 9.884 instead, being the amount of acres equaling 4 hectares.
Press again and you will see and 4.000 below confirming what was just said.
Leave the catalog via and the display will return to 9.884.
The constant T o
may be useful for conversions of temperatures, too; it is found in the catalog CONST and is not repeated here since being only added or subtracted. The conversion factors or divisors listed below for your information are user transparent in executing a conversion – those printed on light green background in this table apply exactly.
Conversion
°C °F
°F °C
° G
° rad acres ha
* 1.8 + 32
- 32 ) / 1.8
/ 0.9
* π / 180
* 0.4046873 ar.
dB atm Pa
AU km bar Pa
Btu J cal J cft l
Remarks Class
Temperature
Temperature
Converts to ‗grads‘ or ‗gon‘ Angle
Equals D R
1 ha = 10
4 m²
Angle
Area
20 lg
a
1 a
2
Amplitude ratio
* 1.01325
E 5
* 1.495979
E 8 Astronomic units
* 1 E 5
* 1055.056 British thermal units
* 4.1868
* 28.31685 Cubic feet
Ratio
Pressure
Length
Pressure
Energy
Energy
Volume
28
For most readers, many of the units appearing in CONV may look obsolete at least. They die hard, however, in some corners of this world. All these corners have in common is English being spoken there. For symmetry reasons, we may also add some traditional Indian and Chinese units. Anyway, this catalog provides the means to convert local to common units.
WP 34S Owner‘s Manual
Edition 2.2 Page 82 of 103
Conversion cm inches / 2.54 dB ar. 10
R dB
20
Remarks
Amplitude ratio dB pr. 10
R dB
10 fathom m * 1.8288 feet m * 0.3048 flozUK ml * 28.41306 flozUS ml * 29.57353 galUK
l * 4.54609 galUS l * 3.785418
G ° g oz
G rad g tr.oz ha acres
* 0.9
/ 28.34952
* π / 200
/ 31.10348
/ 0.4046873
Power ratio
1 l =
1
/
1000
m
3
Grads or gon
1 ha = 10000 m²
HP e
W hpUK W
* 746
* 745.6999 inches cm * 2.54 inHg Pa * 3386.389
Electric horse power
British horse power
J Btu
J cal
J kWh
/ 1055.056
/ 4.1868 km AU
/ 3.6
E 6 kg lb / 0.4535924 kg stones / 6.35029318
/ 1.495979
E 8 Astronomic units km l.y.
/ 9.460730
E 12 Light years km miles / 1.609344 km nmi km pc
/ 1.852
/ 3.085678
E 16
Nautical miles
Parsec
WP 34S Owner‘s Manual
Edition 2.2
Class
Length
Ratio
Ratio
Length
Length
Volume
Angle
Mass
Angle
Mass
Area
Power
Power
Length
Pressure
Energy
Energy
Energy
Mass
Mass
Length
Length
Length
Length
Length
Page 83 of 103
Conversion Remarks kWh J lbf N lb kg l.y.
km l cft
* 3.6E6
* 4.448222
* 0.4535924
* 9.460730
/ 28.31685 l galUK / 4.54609 l galUS / 3.785418 miles km * 1.609344
E 12 Light years
1 l =
1
/
1000
m
3 m l flozUK / 28.41306 m l flozUS / 29.57353
1 ml = 1 cm
3 mmHg Pa * 133.3224 m fathom / 1.8288 m feet / 0.3048 m yards nmi km
N lbf
/ 0.9144
* 1.852
/ 4.448222
1 torr = 1 mm Hg
Nautical miles oz g
Pa atm
Pa bar
* 28.34952
/ 1.01325
E
Pa psi
/ 1 E 5
Pa inHg / 3386.389
Pa mmHg / 133.3224
/ 6894.757
5
Pa torr pc km
/ 133.3224
* 3.085678
E 16
Ounces
1 Pa = 1 N/m
2
Parsec pr.
dB 10 lg
P
1
P
2 psi Pa * 6894.757
PS(hp) W * 735.4988 rad ° * 180 / π
Power ratio
Pounds per square inch
Horse power
Equals R D
WP 34S Owner‘s Manual
Edition 2.2
Class
Energy
Force
Mass
Length
Volume
Length
Volume
Pressure
Length
Length
Length
Length
Force
Mass
Pressure
Pressure
Pressure
Pressure
Pressure
Pressure
Length
Ratio
Pressure
Power
Angle
Page 84 of 103
Conversion rad G * 200 / π stones kg * 6.35029318 s.tons
t tons t torr Pa tr.oz
g t s.tons t tons
* 0.9071847
* 1.016047
* 133.3224
* 31.10348
/ 0.9071847
/ 1.016047
W HP e
W hpUK
/ 746
/ 745.6999
W PS(hp) * 735.4988 yards m * 0.9144
Remarks
Short tons
Imperial tons
1 torr = 1 mm Hg
Troy ounces
1 t = 1000 kg
Class
Angle
Mass
Mass
Mass
Pressure
Mass
Mass
Power
Power
Power
Length
You may, of course, combine conversions as you like. For example, filling your tires with a maximum pressure of 30 psi the following will help you at a gas station in Europe and beyond:
resulting in 2.1 bar.
Now you can set the filler and will not blow your tires.
In cases of emergency of a particular kind, remember Becquerel equals Hertz, Gray is the unit for deposited or absorbed energy ( 1 Gy
1 J kg ), and Sievert ( Sv ) is Gray times a radiation dependant dose conversion factor for the damage caused in human bodies.
In this area also some outdated units may be found in older literature: Pour les amis de
Mme. Curie, 1
Ci
3 .
7
10
10
Bq
3 .
7
10
10
decays s
. And for those admiring the very first Nobel laureate in physics, Mr. Röntgen, for finding the x-rays (ruining his hands in these experiments), the charge generated by radiation in matter was measured by the unit 1
R
2 .
58
10
4
As kg
. A few decades ago, Rem (i.e. Röntgen equivalent men) was measuring what Sievert does today.
WP 34S Owner‘s Manual
Edition 2.2 Page 85 of 103
Predefined Global Alpha Labels
There are a few labels employed and provided for particular tasks already. You find them listed in CAT when the respective routines are loaded in XROM. Thus they will not take any steps from user program memory.
WHO
δx
Displays credits to those brave men who did the work.
Provides the step size for differentiation. See f ‘(x) and f ‖(x) in the Index of Operations for more information.
More routines are found at http://wp34s.svn.sourceforge.net/viewvc/wp34s/library/ as text files with extension .wp34s
by convention. This includes, for example, a suite of basic 3D vector operations, a TVM application, and more. You may open these files using e.g. Notepad, and download them following your needs. README_ASM explains the loading procedure.
MESSAGES
There are some commands generating messages, also in the dot matrix section of the display. Four of them, DAY, DAYS+, STATUS, and VERS, were introduced above in the paragraph about display already. Others are PROMPT, αVIEW and many more alpha commands, and the test commands as mentioned above .
Also two constants will return a special display when called: NaN and
will show
or , respectively.
Furthermore, there are a number of error messages. Depending on error conditions, the following messages will be displayed in the mode(s) listed:
Message
Error
Code
Mode(s) Explanation and Examples
2 DECM
Invalid date format or incorrect date in input, e.g. month >12, day >31 etc.
9 Integer
Invalid digit in integer input, e.g. 2 in binary, 9 in octal, or +/- in unsigned mode.
13 All
Caused by calling an operation in a mode where it is not defined, e.g. SIN in hexadecimal.
WP 34S Owner‘s Manual
Edition 2.2 Page 86 of 103
Message
Matrix / dIMEnSIon
No write / In FLASH
Error
Code
Mode(s) Explanation and Examples
1 \ α
An argument exceeds the domain of the mathematical function called. May be caused by roots or logs of negative numbers (if not preceded by ), by 0 / 0, LN(0),
(0),
TAN(90°) and equivalents, ATANH(x) for
Re
1 , ACOSH(x) for Re
1 , etc.
18 All
16 \ α
Set when there is a checksum error either in flash or as part of a serial download. It is also set if a flash segment is otherwise unusable.
Similar to error 1 but a parameter specified in
J or K is out of supported range for the function called. May appear e.g. if LgNrm is called with j < 0.
17 \ α Please see Appendix A .
21 DECM
A matrix isn't square when it should be.
Matrix sizes aren't miscible.
6 All
19 All
8 All
Attempt to address an undefined label.
Attempt to delete program lines while inside a flash segment..
A number exceeds the valid range.
Caused e.g. by specifying decimals >11, word size >64, negative flag numbers, integers ≥2 64
, hours or degrees >9000, invalid times, denominators ≥9999 etc.
A register address exceeds the valid range. May also happen in indirect addressing.
An R-operation (e.g. R.COPY) attempts exceeding valid register numbers (0 .. 99).
A matrix descriptor would go beyond the registers available or a row or column index is too large.
WP 34S Owner‘s Manual
Edition 2.2 Page 87 of 103
Message
Singular / Error
Solve / FAILEd
Error
Code
Mode(s) Explanation and Examples
22 DECM
Attempt to use a LU decomposed matrix for solving a system of equations.
Attempt to invert a matrix when it isn't of full rank.
20 DECM The solver did not converge.
7 PRG
Nested use of solve (SLV and SLVQ), integrate, sum or product is not allowed.
12 All
STOS or RCLS attempt using registers that would overlap the stack. Will happen with e.g.
SSIZE = 8 and STOS 94.
15 DECM
A statistical calculation was started based on too few data points, e.g. regression or standard deviation for < 2 points.
10 All
Keyboard input is too long for the buffer
(should never happen, but who knows).
3 All
An instruction with an undefined op-code occurred (should never happen, but who knows).
14
Integer,
\PRG
Stack or register content is too big for the word size set.
4
5
\ α,
\PRG
Division of a number > 0 (or < 0) by zero.
Divergent sum or product or integral.
Positive (or negative) overflow in DECM
(see above ).
11 PRG Subroutine nesting exceeds 8 levels.
Any key pressed will erase the error message displayed and execute with the stack contents present. Thus, the easiest return to the display shown before the error occurred is pressing a prefix twice.
WP 34S Owner‘s Manual
Edition 2.2 Page 88 of 103
PROGRAMMED INPUT AND OUTPUT
A number of commands may be employed for controlling I/O of programs. In the index above , their behavior is described if they are entered from the keyboard. Executed by a program, however, this will differ in a characteristic way.
With a program running, the display will be updated at certain instances only instead of after each operation. So where a command in manual mode shows an information until the next key is pressed, it will show it until the next display update in automatic mode.
Such an update will occur with PROMPT, PSE, STOP, VIEW, VW
+, and
VIEW only.
This allows for the following operations (please note parameters are omitted here):
Output of messages or other information for a defined time interval using the following code segment
…
…
(or simply PSE alone) for plain numeric calculated output or
…
(or even VW
+)
… for complex alphanumeric information you composed in alpha .
Asking (―prompting‖) for numeric input employing
…
(or VW
+)
… or simply PROMPT, the latter being identical to VW
+ X plus STOP.
Whatever number you key in will be in X when you continue the program by pressing . If you want it elsewhere, take care of it.
Prompting for alphanumeric input by
…
…
Whatever you key in will be appended to alpha here. Again, the program will continue when you pressed .
Please see the index for more information about these commands and their parameters.
WP 34S Owner‘s Manual
Edition 2.2 Page 89 of 103
INTERACTIVE PROGRAMMING
This chapter deals with writing programs that interact with the user. Topics covered are the display of messages, getting input from the user, hot keys and truly interactive "real time" programs.
Interrupting a Program for Display of Information
When a program is started, the display contents are replaced by the "Running Program" message. To display a number while a program is executing, use VIEW in programming and specify a register to display. Here, X is a valid parameter so you can present the standard top stack level contents to the user. The command formats the number to the present settings and updates the LCD to display it. This causes a small overhead so expect that your program slows down a bit with each update. This is especially true if the displays follow each other in a tight loop because the flicker avoidance logic needs to wait for a complete display refresh cycle before the next update is allowed.
Another way to show what would normally appear on the display without a program running is to use the PSE instruction specifying the time in 10ths of seconds to suspend execution. A time of zero will have the same effect as a VIEW X instruction. PSE following VIEW s works as expected: it will display the contents of address s . The display will then stay unchanged until the next VIEW or PSE instruction is executed, not only for the time specified with PSE. The next PSE or STOP will switch back to the normal display of x . VIEW s followed by STOP will display the contents of address s until the user presses .
To make things clearer: VIEW immediately displays the register when encountered in program execution. When followed by PSE or STOP, the display persists. Only the next
PSE or STOP (or keyboard entry after the program has halted) will revert to the normal x display. To make sure that STOP or PSE always display a specific information it is best to directly precede it by the respective VIEW instruction. There is no way to get the
"Running Program" message back once it has been replaced by a programmed display.
Generally speaking, a message is a string of characters that is shown in the upper region of the display. The program interface to this area is via the alpha register. You need to switch to alpha mode to access most of the commands that deal with this register.
The annunciator INPUT lights if alpha mode is active. The X.FCN catalogue changes in alpha mode to contain alpha commands. Displaying a message will normally start with a
CL[alpha] instruction because most commands append their output to what is already stored. To save space, characters in program mode may be entered in groups of three by typing while already in alpha mode. This saves one program step per three characters but does not allow all special symbols to be entered because the catalogues are not available in this mode. Single characters and grouped characters can be freely mixed. The register is 31 characters wide. The display capacity is considerably smaller and depends on the width of each symbol. The display switches to a smaller font if necessary. The contents can be scrolled in interactive alpha mode with the up and down arrow keys (as described above).
If you just want to display a text message and no number with it, use αVIEW. To get to this command you must be out of alpha mode and open the P.FCN catalogue.
brings you to the alpha commands. The αVIEW display starts at the first character of the string. The numeric portion of the LCD is replaced by three dashes. You can of course display a message together with a chosen register. Go to alpha mode and press
WP 34S Owner‘s Manual
Edition 2.2 Page 90 of 103
VIEW. This will produce the
αVW+ nn command. It is meant to display alpha together with ('+') numeric data coming from any register. As with VIEW, X is allowed here. The above comments regarding PSE or STOP following any of these commands are valid here, too.
Another way to display the alpha register is to switch to alpha mode with αON. The main difference is that you are presented the tail of the string instead of its head. Also, a PSE is necessary to update the actual display which αON alone does not do. If followed by a
STOP, alpha mode stays on causing user input to go to the upper display! αOFF returns everything to normal.
Temporary Displays
Whenever the display does not show the actual contents of the X register in the current mode, this is considered a temporary display. To distinguish this from the normal display, the RPN annunciator is off during temporary displays and on otherwise. The following displays are considered temporary:
1. Any errors,
2. αVIEW,
3. αVW+ nn ,
4. VIEW nn where nn is not X,
5. VIEW X if encountered in a program because X may have changed before the stop,
6. H.MS display,
7. Temporary display in another base (not programmable).
Press or to get back to the normal display.
Data Input
The easiest way of getting user input, apart from expecting everything on the stack, is just stopping the program with STOP, letting the user input a number and let him press
to continue execution. Without any clue what the program is asking for, this is only suitable for very simple programs. The least you want to do is present a message to the user what he is supposed to enter when the program stops. This can be done with any of the [alpha]VIEW commands followed by STOP. There is a shorthand especially made for this: PROMPT. It is a combination of [alpha]VW+ X and STOP. It displays the alpha register together with the current X register and halts program execution. This is good for entering a lengthy list of parameters in a given order without much programming.
Hotkeys
A more versatile way of doing things is using the dedicated keys A to D in the top row. If the user presses one of these keys the program executes the next subroutine or program with a label of the same name. If you have more than one program using labels A to D in RAM or in a flash region, it's necessary to move the program counter (PC) to the top of the program and stop there. A typical program structure might be the following:
WP 34S Owner‘s Manual
Edition 2.2 Page 91 of 103
LBL 'MYP'
CL[alpha]
[alpha]'Hel'
[alpha]'lo!'
LBL 00
PROMPT
BACK 01
LBL A
ENTRY?
SKIP 01
XEQ 01
STO 01
GTO 00
LBL B
...
This sets up a message and stops. does nothing, it simply returns to the prompt. If the user enters a number and hits A, the program starts with the ENTRY? test which is true if the user has entered fresh data. The input will be stored in register 01 and the program jumps back to the prompt. If the user has not entered any information after the last prompt, subroutine 01 will be called to compute a new value which is then stored and displayed. This is the way the TVM application is implemented.
Keyboard Codes
Sometimes, the hot keys to aren't enough. But there are ways to extend the number of directly addressable subroutines by a simple trick: shorthand addressing of numeric labels. To make this possible, each key is identified by a row and a column, each starting with one.
A B C D -> CPX
11 12 13 14 15 16
STO RCL Rv f g h
21 22 23 24 25 26
ENTER^ x<>y +/- EEX <-
31 32 33 34 35
XEQ 7 8 9 /
41 42 43 44 45
^ 4 5 6 x
51 52 53 54 55
v 1 2 3 -
61 62 63 64 65
EXIT 0 . R/S +
71 72 73 74 75
Whenever you are asked for the entry of a two-digit label, any of the keys marked in italic in the above picture can be used as direct input. The label will be replaced by the row/column code of the respective key. Some keys are not available this way because they have a predefined meaning in this context. They can still be used for a short address by preceding the key with the f prefix. Only the f prefix itself cannot be used for
WP 34S Owner‘s Manual
Edition 2.2 Page 92 of 103
shorthand addressing. If you want to associate a program with the key , just put the label 21 in front of the routine and it can be conveniently called with by the user.
Direct Keyboard Access
The same codes are returned by the KEY? command which allows true "real time" response to user input from the keyboard. KEY? takes a register argument (X is allowed but does not lift the stack) and stores the key most recently pressed during program execution in the specified register. R/S and EXIT cannot be queried, they stop program execution immediately. The keyboard is active during execution but it is of course desirable to show a message and suspend the program with the PSE command while waiting for user input. PSE is interrupted by a key press, so you can simply use a PSE 99 statement in a loop to wait for input. KEY? acts as a conditional at the same time so a typical user input loop will look like this:
LBL 'USR'
CLα
α 'KEY'
α ?
LBL 00
αVIEW
PSE 99
KEY? 00
GTO 00
LBL?->00
XEQ->00
GTO 00
This code fragment prompts for a key and stores it in register 00. The line directly after
KEY? is executed when no key was pressed. The statement KEY? is only executed every 9.9 seconds if the user does not press a key. If he does, the PSE is immediately terminated, KEY? is executed, finds the key code and stores it in register 00. The
LBL 00 instruction checks if a label corresponding to the key code has been defined and executes it if found. Instead of the dumb waiting loop, the program can do some computations and update the display before the next call to PSE and KEY? – think of a lunar lander game.
To be even more versatile, the instruction KTY? nn is designed to return the key type of a row / column code in register nn : 0 to 9 for the respective digits, 10 for the other numeric keys (. , +/- and EEX), 11 for any of the three shift keys and 12 for the rest. An invalid code in the target register throws an "Invalid Range Error".
If you decide not to handle the key in the program you may feed it back to the main processing loop of the calculator with the PUTK nn command. What happens is that the program halts and the key is treated as if pressed after the stop. This is especially useful if you want to allow numeric input while waiting for some special keys like the arrows. This allows writing of a vector or matrix editor in user code. After execution of the
PUTK command the user is responsible for letting the program continue its work by pressing or a hot key.
WP 34S Owner‘s Manual
Edition 2.2 Page 93 of 103
APPENDIX A: SUPPORT FOR FLASHING, SERIAL I/O ETC.
How to Flash Your HP 20b or 30b
You may do the flashing yourself. Then you need your calculator, a special connecting cable, and specific software on your PC or Mac. A PC featuring an hardware serial port and running
Windows XP is beneficial. Please read this paragraph completely before actually starting the procedure.
You will get the necessary software – the SAM-BA In-system Programmer – here for free: http://www.atmel.com/dyn/products/tools_card.asp?tool_id=3883
Install it as explained by Atmel.
You may get the cable from Gene Wright.
The specific file you will need to transmit to your calculator to make it your WP 34S is called calc.bin
and is included in the zipped package you can download from here: http://sourceforge.net/projects/wp34s/files/
Alternatively, you may download calc.bin
alone from http://wp34s.svn.sourceforge.net/viewvc/wp34s/trunk/realbuild/
Now, having got these three (SAM-BA, the cable, and calc.bin
) , please turn to the file http://dl.dropbox.com/u/10022608/Flashing%20a%2020b%20Calculator.pdf
(edited by Tim
Wessmann and Gene Wright). Read it thoroughly for information about connecting and flashing.
ATTENTION: If your PC does not feature an hardware serial interface, you will need an
USB-to-serial converter to connect the special cable to your PC. Following our experience, converters containing FTDI chips will work – others may not.
On other operating systems than XP flashing may work or not (definitively not on Windows
2000 or earlier). Please check.
On Windows 7 load MS Windows Virtual PC and Windows XP Mode, then work therein.
Then proceed as described in Flashing a 20b Unit in said file, steps 1 to 3 only.
ATTENTION: Flashing your HP 20b or 30b will erase the HP firmware in step 3, meaning your business calculator will be gone then. The firmware will be replaced with the WP 34S file completely! After this flash is finished, you will have a WP 34S RPN Scientific – i.e. your calculator will react as documented in this very manual.
This also means your device will not do anything useful for you between step 3 and 13. It may even look dead – it is not, be assured, at least it will just be eating your batteries (see below)! If you (have to) interrupt the flashing process at any time in this interval for any reason whatsoever , don‘t worry: simply start again. You may, however, not get any feedback displayed in step 3 anymore. That does not matter, just stick to the procedure.
As long as the cable is connected to your calculator, it will draw a considerable current from the calculator batteries. If you happen to hang anywhere in the flashing process, also the processor is left running at full speed. So chances are high your coin cells will be drained while you are trying to find out what is going wrong. Thus it is wise to disconnect the cable from your calculator when you will not need the cable for the next couple of minutes. For repeated flashing, an external 3V DC supply may pay very fast. Take care to connect + to the outer and – to the inner contact. The following will work with a good 3V supply only.
WP 34S Owner‘s Manual
Edition 2.2 Page 94 of 103
Having completed step 3 of said file, call your SAM-BA for step 4. It may take a long time to start up (some sixty seconds), so be patient. When it launches (step 5), a window pops up:
Choose the correct connection
(take the port you put your cable in – it may differ from what is printed here). Select the board built in your calculator (i.e.
AT91SAM7L128-EK as shown).
Press [Connect] then. This was step 6.
In step 7, put in the address of calc.bin
on your PC. Then continue according to steps 8 to
13. Not reaching step 7 may be due to low supply voltage on your calculator (see above).
After flashing successfully, a keyboard overlay is very helpful for further work since most labels deviate from the ones used on said business calculators. You may get adhesive overlays from
Eric Rechlin. Preliminary paper overlays are most easily made of a file provided here: http://wp34s.svn.sourceforge.net/viewvc/wp34s/artwork/wp34s_overlay.png
Set the overall width of this picture to 68mm and print it. Cut it out, span it over your
WP 34S using some transparent adhesive tape, and you are done.
Commands for Handling Flash Memory on Your WP 34S
Flash memory is very useful for backups as explained above . Alternatively to the commands
SAVE and LOAD contained in X.FCN (see the index of operations ), you may use another approach. Hold down (i.e. ) and press one of the following keys:
for backup:
for restore:
Creates a copy of the RAM in flash memory like SAVE does.
Restores the most recent backup like LOAD does.
S (i.e. ) for SAM-BA: Clears the GPNVM1 bit and turns the calculator off.
ATTENTION: You can now only boot in SAM-BA mode! Without the SAM-BA software and the cable mentioned above, you will be lost!
These ON key combinations have to be pressed twice in a row without releasing the ON key to be executed.
We recommend doing a SAVE or + before flashing a new release! After flashing, your backup will still be available – if you used + to get into SAM-BA boot mode and didn't accidently press the ERASE button on the cable.
Further flash memory operations are PRCL, PSTO, P
, RCF, RCF.RG, and RCF.ST. See the index .
WP 34S Owner‘s Manual
Edition 2.2 Page 95 of 103
Mapping of Memory Regions to Emulator State Files
Region Start address in flash
State file Remarks
Unnamed
0x11FC00 wp34s-R.dat
Backup of 112 registers, flags and state.
0 0x11F800 wp34s-0.dat Backup of program memory (506 steps).
1 0x11F400 wp34s-1.dat
2 0x11F000 wp34s-2.dat
3 0x11EC00 wp34s-3.dat
4 0x11E800 wp34s-4.dat
5 0x11E400 wp34s-5.dat
6 0x11E000 wp34s-6.dat
7 0x11DC00 wp34s-7.dat
8 0x11D800 wp34s-8.dat
9 0x11D400 wp34s-9.dat
RAM n/a wp34s.dat
Space for generic user programs. Each region contains 506 steps again.
The files wp34sn .dat
are written whenever a respective flash command is executed.
You will find some sample files at Sourceforge.
ATTENTION: Flash regions ≥6 are available in the emulator only. They may be, however, accessible also for the calculator in an earlier version not yet featuring the matrix command set.
Backup of the emulator RAM area (registers, state, and programs) – this file is written only when exiting the emulator.
All files are only read into memory at emulator startup.
Data Transfer Between Your WP 34S and Your PC (SAM-BA)
This method is superseded by the one using serial I/O commands – see next paragraph. It is still interesting enough to leave it here as a reference.
The entire RAM is saved to address 0x11F800 (relative address 0x1F800 ) by SAVE or its equivalent + . This content can be copied to your PC or loaded from it if the special interface cable mentioned above is connected. Then, the transfer is performed as follows:
1. From calculator to PC: a. Press + , then + (see below), then + . b. Press once again and start SAM-BA on the PC. Both devices should connect. c. Set the start address to 0x11F800 and the size to 0x800 . d. Enter a file name of your choice in the receive field. You can now receive the file with
SAM-BA. e. Move it into your emulator directory (where name wp34s.dat
. wp34sgui.exe
is stored) under the f. The emulator should accept the file. Your registers and programs will then be in place.
WP 34S Owner‘s Manual
Edition 2.2 Page 96 of 103
g. To get your calculator back in business, start the "Boot from flash" script in SAM-BA – the same procedure you should know from flashing the firmware. h. Reset and press to power up. Restore with +
. If RAM is lost (most probably due to an accidental press of the ERASE button on the cable), the most recent backup (i.e. the one of step a. here) will be automatically restored.
2. From PC to calculator: a. Execute steps 1.a + b. b. Set the start address to 0x11F800 . c. Point SAM-BA to your wp34s.dat
file from the emulator. d. You can now send the short file with SAM-BA. e. Execute steps 1.g + h.
The program regions accessible with the commands PSTO, PRCL and P are stored at addresses mentioned in the table above and have a length of 0x400 (1 kB) each. The emulator creates files wp34sn .dat
, with n being the region number. You can handle these files the same way as the complete state file from the emulator. The regions have identical formatting and can be swapped by copying their data to the ‗wrong‘ place. The register and state portion of the backup area at 0x11FC00 is formatted differently.
If you want to get your emulator data from your PC into your calculator all in once, do the following in Windows: copy /b calc.bin+wp34s-5.dat+wp34s-4.dat+ …
+wp34s-1.dat+wp34s.dat calc-full.bin
As an alternative, the following will copy the backup data instead of the RAM state file: copy /b calc.bin+wp34s-5.dat+wp34s-4.dat+ …
+wp34s-1.dat+wp34s-0.dat+wp34s-R.dat calc-full.bin
The resulting file can be transferred into flash and all data will be readily available.
Data Transfer Between Your WP 34S and Your PC (Serial I/O)
You will need the special interface cable mentioned above once again, or a modified 20b or 30b as described elsewhere. Said special cable draws current from the batteries of your calculator; it shall thus be disconnected from your WP 34S as soon as not needed anymore.
Communication is between your WP 34S and another WP 34S. The Windows emulator counts as a valid partner so you can exchange data between your WP 34S and the PC. Since PCs tend to have more than one port you have to tell the emulator which one to use. Create a text file wp34s.ini
in the directory where the state files wp34s.dat
reside and put the name of the port as the only line in this file, e.g. COM5: – the very same port SAM-BA uses to access your
WP 34S for flashing.
The following commands allow for sending programs, registers or all RAM. They are found in the
P.FCN catalog.
On the receiving device, start the command RECV. It will display .
On the sender you have four choices:
1. SENDP will send the user program space. After successful termination, the receiver will display .
WP 34S Owner‘s Manual
Edition 2.2 Page 97 of 103
2. SENDR will send the registers 00 to 99. The receiver will display after successful termination.
3. SENDA will send the complete 2 KB of non-volatile memory. The receiver will display
after successful termination.
4. SENDL n will send a library region directly. It will arrive in RAM and may be stored using
PSTO.
The commands for sending and receiving feature a fixed timeout of some 10 seconds for setting up the connection. After an interval of inactivity of said length, is displayed indicating no communication has occurred. If appears in the middle of a transmission try again.
On a device without the crystal installed, you may get said error because of the baud rate setting may be a bit too far off. To determine the speed, use the loop
and let it run for 30 seconds. The expected result at nominal speed is around 191000.
The I/O commands accept a correction factor in percent in X . Try with 95 if your device is a bit too slow or 105 if it is a bit too fast. Values between 80 and 120 are accepted – all other are ignored. On the emulator or with the crystal installed, x is ignored.
The little "=" annunciator is lit while the serial port is in use. can be used to abort the communication.
More Keyboard Commands Employing ON
+ or : Adjust display contrast.
+ : Tells the system a quartz c rystal is installed for the real time clock. The quartz is inevitable prerequisite for the clock being useful in medium to long range (see TICKS). Its installation is a hardware modification described elsewhere.
ATTENTION: If this command is entered though the hardware does not contain said modification, the system will hang and can only be brought back to live with a reset or a battery pull!
+ : Enters d ebugging mode (use at your own risk).
+ : Toggles the radix mark as does.
WP 34S Owner‘s Manual
Edition 2.2 Page 98 of 103
APPENDIX B: MORE ROUTINES AND COMMANDS
Library Routines
TVM and WHO live in the library file wp34s-1.dat
, located in the library directory. Here is how to install these two routines in the emulator and on the calculator.
1. Copy wp34s-1.dat
into the emulator directory.
2. Start the emulator and the calculator with the serial cable still connected. Make sure a file wp34s.ini
exists in the emulator directory naming the COM port in use.
3. Make sure you have a backup of your programs on the calculator and on the emulator.
4. Use PRCL 1 on the emulator to copy the library into user program RAM.
5. Use RECV on the calculator and SENDP on the emulator. This will transfer the program memory of the emulator to the calculator.
6. On the calculator, use PSTO to save the library.
7. Restore your backups.
Alternatively use SAM-BA to transfer the image directly to a RAM region as described elsewhere.
Internal Commands (Use at Your Own Risk)
Some commands are used in internal routines exclusively and are not accessible from the keyboard. Others are placed here until they are sufficiently tested for being officially released. They are listed below for sake of a complete documentation only:
Name iC n
Purpose and remarks
Recalls internal constants, selected by the number specified:
0 0
1 1
2 5.01402
3 15.02903
Kronrod only weight loop initializer (constants 5 - 14 below)
Gauss-Kronrod weight loop initializer (constants 15 - 29 below)
4 0.149445554002916905664936468389821
5 0.995657163025808080735527280689003
6 0.011694638867371874278064396062192
7 0.930157491355708226001207180059508
8 0.054755896574351996031381300244580
Midpoint location is 0.5.
Kronrod weight for midpoint k10
Kronrod location of k0 and k20
Kronrod weight for k0 and k20
Kronrod location of k2 and k18
Kronrod weight for k2 and k18
9 0.780817726586416897063717578345042
10 0.093125454583697605535065465083366
11 0.562757134668604683339000099272694
12 0.123491976262065851077958109831074
13 0.294392862701460198131126603103866
14 0.142775938577060080797094273138717
15 0.973906528517171720077964012084452
16 0.066671344308688137593568809893332
17 0.032558162307964727478818972459390
Kronrod location of k4 and k16
Kronrod weight for k4 and k16
Kronrod location of k6 and k14
Kronrod weight for k6 and k14
Kronrod location of k8 and k12
Kronrod weight for k8 and k12
Location of g0, g9, k1 and k19
Gauss weight for g0 and g9
Kronrod weight for k1 and k19
WP 34S Owner‘s Manual
Edition 2.2 Page 99 of 103
Name Purpose and remarks
18 0.865063366688984510732096688423493
19 0.149451349150580593145776339657697
20 0.075039674810919952767043140916190
21 0.679409568299024406234327365114874
22 0.219086362515982043995534934228163
23 0.109387158802297641899210590325805
24 0.433395394129247190799265943165784
25 0.269266719309996355091226921569469
26 0.134709217311473325928054001771707
27 0.148874338981631210884826001129720
28 0.295524224714752870173892994651338
29 0.147739104901338491374841515972068
Location of g1, g8, k3 and k17
Gauss weight for g1 and g8
Kronrod weight for k3 and k17
Location of g2, g7, k5 and k15
Gauss weight for g2 and g7
Kronrod weight for k5 and k15
Location of g3, g6, k7 and k13
Gauss weight for g3 and g6
Kronrod weight for k7 and k13
Location of g4, g5, k9 and k11
Gauss weight for g4 and g5
Kronrod weight for k9 and k11
Constants 2 .. 29 are for the 10 / 21 point Gauss-Kronrod quadrature used by the internal integration command. Locations are in the range (0, 1) which is scaled to match the interval of integration. The quadrature sums the weight times the function value at each location to estimate the integral. In Gauss-Kronrod schemes the
Gauss points are common to both quadratures although the weights are different.
This means two estimates of the integral can be performed without increasing the number of function evaluations which in turn allows an estimate of the error to be made. The cost for this is a reduction in the degree of polynomial function that is always integrated exactly.
The following two solver commands SLVI and SLVS may use some hidden registers and flags. The start points of the respective register and flag blocks are passed as one argument n .
Registers: n +0 , n +1: first two estimates a and b for the root n +2: n +3: n +4: third estimate c function value at first estimate f( a ) function value at second estimate f( b )
Flags: n +0 ..
n +7: an eight bit iteration counter n +8: ―bracket flag‖ – true if we've got an interval with f(a) * f(b) < 0 n +9: true if all function evaluations have been constant so far
SLVI n Initializes the solver. SLVI clears the iteration counter, takes a and b and calculates f( a ) and f( b ) , sets the last 2 flags accordingly, and produces a guess c . There is no stack interaction.
SLVS n Solver step. Updates the internal solver state based on the last function evaluation.
In particular, SLVS takes a , b , c , f( a ) , and f( b ) from the register block plus f( c ) from
X and updates the register values so that c and f( c ) replace one of a and f( a ) or b and f( b ).
It also produces a new guess c and returns zero in X if the solving should continue and non-zero if not. Otherwise, the stack isn't altered.
WP 34S Owner‘s Manual
Edition 2.2 Page 100 of 103
Name Purpose and remarks
The built in solver loop looks like this in principle, assuming n = 0 :
SLVI ; calculate f( a ) and f( b ) and initialize the registers and flags
LBL 00
RCL 02 ; recall c
XEQUSR ; call the user's subroutine calculating f( c ) x≈ 0? ; test if the solution has converged
GTO 01 ; converged, so exit the routine
SLVS x= 0?
; update estimates
; should we continue?
GTO 00 ; loop back again
LBL 01
RCL 02 ; best guess so far
RTN
The actual solver is fairly complex. A combination of quadratic interpolation and a guarded secant method is used.
XEQUSR Calls a user subroutine (used by SLV,
∫ , Π and ). The subroutine is defined by the argument to the initial command (either numeric of alpha label).
WP 34S Owner‘s Manual
Edition 2.2 Page 101 of 103
APPENDIX C: RELEASE NOTES
Date Release notes
1 9.12.08 Start
1.1 15.12.08 Added the table of indicators; added NAND, NOR, XNOR, RCLWS, STOWS, //, N, SERR, SIGMA,
< and >; deleted HR, INPUT, 2 flag commands, and 2 conversions; extended explanations for addressing and
COMPLEX & …; put XOR on the keyboard; corrected errors.
1.2 4.1.09 Added ASRN, CBC?, CBS?, CCB, SCB, FLOAT, MIRROR, SLN, SRN, >BIN, >DEC, >HEX, >OCT, BETA, D>R,
DATE, DDAYS, D.MY, M.DY, Y.MD, CEIL, FLOOR, DSZ, ISZ, D>R, R>D, EMGAM, GSB, LNBETA, LNGAMMA,
MAX, MIN, NOP, REAL, RJ, W and WINV, ZETA, %+ and %-; renamed the top left keys B, C, and D, and bottom left EXIT.
1.3 17.1.09 Added AIP, ALENG, ARCL, AROT, ASHF, ASTO, ATOX, XTOA, AVIEW, CLA, PROMPT (all taken from 42S),
CAPP, FC?C, FS?C, SGMNT, and the …# commands; renamed NBITS to BITS and STOWS to WSIZE; specified the bit commands closer; deleted the 4 carry bit operations.
1.4 10.2.09 Added CONST and a table of constants provided, D>J and J>D, LEAP?, %T, RCL and STO and , and 2 forgotten statistics registers; deleted CHS, EMGAM, GSB, REAL and ZETA; purged and renamed the bit operations; renamed many commands.
1.5 5.3.09 Added RNDINT, CONV and its table, a memory table, the description of XEQ B, C, D to the operation index, and a and g e
to the table of constants; put CLSTK on a key, moved CL and FILL, changed the % and log labels on the keyboard , put CLALL in X.FCN; checked and cleaned alpha mode keyboard and added a temporary alpha keyboard; rearranged the alphabet to put Greek after Latin, symbols after Greek consistently; separated the input and non-programmable commands; cleaned the addressing tables.
1.6 12.8.09 Added BASE, DAYS+, DROP, DROPY, E3OFF, E3ON, FC?F, FC?S, FIB, FS?F, FS?S, GCD, LCM, SETDAT,
SETTIM, SET24, SINC, TIME, VERS, αDAY, αMONTH, αRC#; %, as well as F-, t-, and 2
-distributions and their inverses; reassigned DATE, modified DENMAX, FLOAT, αROT, and αSHIFT; deleted BASE arithmetic, BIN,
DEC, HEX, and OCT; updated the alpha keyboards; added flags in the memory table; included indirect addressing for comparisons; added a paragraph about the display; updated the table of indicators; corrected errors.
1.7 9.9.09 Added P.FCN and STAT catalogs, 4 more conversions, 3 more flags, Greek character access, CLFLAG,
DECOMP, DENANY, DENFAC, DENFIX, I β, IΓ, αDATE, αRL, αRR, αSL, αSR, αTIME, 12h, 24h, fraction mode limits, normal distribution and its inverse for arbitrary µ and
, and Boolean operations working within FLOAT; deleted αROT, αSHIFT, the timer, and forced radians after inverse hyperbolics; renamed WINV to W –1
, and beta and gamma commands to Greek; added tables of catalog contents; modified label addressing; relabeled PRGM to P/R and PAUSE to PSE; swapped SHOW and PSE as well as
% and % on the keyboard; relabeled Q; corrected CEIL and FLOOR; updated X.FCN and alpha commands; updated the virtual alpha keyboard.
1.8 29.10.09 Added R-CLR, R-COPY, R-SORT, R-SWAP, RCLM, STOM, alpha catalogs, 1 more constant and some more conversions, a table of error messages, as well as the binomial, Poisson, geometric, Weibull and exponential distributions and their inverses; renamed some commands; put
√‾
instead of
on hotkey D .
1.9 14.12.09 Added two complex comparisons; swapped and changed labels in the top three rows of keys, dropped CLST; completed function descriptions in the index.
1.10 19.1.10 Added IMPFRC, PROFRC,
C
ENTER, αBEG, αEND, and an addressing table for items in catalogs; updated temporary alpha mode, display and indicators, RCLM and STOM, alpha-commands and the message table; renamed the exponential distribution; wrote the introduction.
1.11 21.9.10 Changed keyboard layout to bring Π and to the front, relabeled binary log, swapped the locations of π, CLPR, and STATUS, as well as SF and FS?; created a menu TEST for the comparisons removed and the other programmable tests from P.FCN; added %MG, %+MG, %MRR, RESET, SSIZE4, SSIZE8, SSIZE?,
C
DROP,
C
FILL,
C
R ,
C
R , registers J and K, a table of contents and tables for stack mechanics and addressing in complex operations; updated memory and real number addressing tables, DECOMP, αOFF, αON, Π, and ; renamed ROUNDI,
WSIZE?, β(x,y), Γ(x) and the constant p
0
; deleted DROPY (use x y, DROP instead), αAPP, αBEG, αEND, and the ―too long error‖ message; deleted Josephson and von Klitzing constants (they are just the inverses of other constants included in CONST already); brought more symbols on the alpha keyboard.
1.12 22.12.10 Modified keyboard layout ; added catalogs MODE and PROB; changed mode word, catalog contents and handling
(XEQ instead of ENTER), as well as some non-programmable info commands; expanded IMPFRC and
PROFRC; added a paragraph about the fonts provided and explained alpha catalogs in detail; added PRIME? and some conversions; deleted FRACT, OFF and ON.
1.13 3.2.11 Modified keyboard layout ; modified αTIME, radix setting, H.MS+ and H.MS-; added EVEN?, FP?, INT?, LZOFF,
LZON, ODD?, RCLS, STOS, returned FRACT; added and renamed some conversions; updated the paragraph about display; added appendices A and B; baptized the device WP 34S.
WP 34S Owner‘s Manual
Edition 2.2 Page 102 of 103
1.14 18.3.11 Started the Windows emulator.
Added DEC and INC, renamed FLOAT to DECM; redefined αTIME and H.MS mode; updated appendix A; documented the annunciators BEG and = as well as underflows and overflows in H.MS; corrected some errors showing up with the emulator.
1.15 21.3.11 Modified FIX, removed ALL from MODE, updated CONV.
1.16 27.3.11 Added LBL?
, f‘(x), and f‖(x); modified PSE; upgraded catalog searching.
1.17 9.5.11
1.18 5.6.11
Modified keyboard layout for adding a fourth hotkey; added AGM, BATT, B n
*, Cauch, Lgnrm, Logis and their inverses, all the pdf, COV, CUBE, CUBERT, DEG , ENGOVR, ENTRY?, erfc, GRAD , GTO . hotkey , KEY?,
RAD
, SCIOVR, SERRw, SLVQ, sw, sxy, TICKS, TVM, xg,
,
m
,
p
,
,
n
, B w, (-1)
X
, the polynomials, four angular conversions, four Planck constants, the regional settings, global alpha labels, and three messages; renamed most cdf; changed DEG, RAD, GRAD to leaving angular mode as set; altered PSE for early termination by keystroke; made D.MY default instead of Y.MD; moved degrees to radians conversions to CONV; removed
C
CLx,
H.MS mode, %+ and %-; corrected errors.
Expanded program memory; modified label addressing (A ≠ ‗A‘) and fraction mode limits, changed ANGLE to work in real and complex domains, renamed MOD to RMDR, changed the keyboard layout; put BACK, ERR,
SKIP, and SPEC? to the main index; added CAT and the I/O commands for flash memory, expanded R-COPY; corrected x α.
2.0 21.7.11 Entered beta test phase.
Added DAY, MONTH, YEAR, FAST, SLOW, S.L, S.R, VW α+, flag A, ON + and –, some constants, and a paragraph about I/O; renamed old DAY to WDAY, RRCL to RCFRG, SRCL to RCFST; added an inverse conversion shortcut, stones kg, and changed Pa mbar to Pa bar; modified the VIEW commands, ALL, DISP, MODE,
RCLM, STOM, and X.FCN; repaired hyperlinks; corrected some errors; included flash.txt; updated the first chapters, explained stack mechanics in more detail.
2.1 3.10.11 Added serial I/O commands, DEL
P
, DSL, EXPT, IBASE?, INTM?, ISE, KTY?, MANT, NEXTP, PUTK, REALM?,
RM, RM?, SMODE?, TOP?, x √y, signed tests for zero, some constants, and the paragraph about interactive programming; updated the values in CONST to CODATA 2010, also updated SLVQ, SHOW, , Π, and the paragraphs about statistics, predefined alpha labels and memory; corrected some errors; deleted complex ANGLE,
BIN, DEC, HEX, and OCT; redistributed the contents of X.FCN and P.FCN; renamed S.L and S.R to
SDL and SDR
; put ‗?‘ on the alpha keyboard and moved £ to P to make room for
; expanded Appendix A; reorganized the structure of the document; added first aid to the front page; rewrote the keyboard chapter.
2.2 1.11.11 Added MSG, y , z , and matrix operations, a paragraph about them and two new error messages for them, plus a footnote for DEL
P
; updated the introduction to statistics.
26.11.11 Expressed the flash access more clearly.
WP 34S Owner‘s Manual
Edition 2.2 Page 103 of 103
다운로드