Aqua Medic LEDspot 100 is a high-quality lighting solution designed specifically for aquarium use, offering optimal illumination for your aquatic environment. With its powerful 100W LED chips emitting a bright 12,000 Kelvin light, the LEDspot 100 ensures excellent visibility and clarity, enhancing the beauty of your underwater world. Its compact size and adjustable mounting options, including chain suspension or screw-on installation, provide versatile placement possibilities to suit your aquarium setup.
advertisement
LEDspot 100/200
Bedienungsanleitung D
Mit dem Kauf dieser Leuchte haben Sie sich für ein Qualitätsprodukt entschieden. Sie ist von
Fachleuten speziell für den aquaristischen Gebrauch entwickelt und erprobt worden. Hochwertige
Technik und beste Materialien sowie modernes Design gewährleisten, dass Sie lange Freude an
Ihrer Aquarienbeleuchtung haben werden.
AB Aqua Medic GmbH
Gewerbepark 24, 49143 Bissendorf, Germany
___________________________________________________________________________________________
1
1. Technische Daten
Netzanschluss: 230 Volt, 50 Hz, andere Ausführungen (für USA etc.) siehe Typenschild.
Leuchtmittel: 100 W bzw. 200 W LED Chips (12.000 Kelvin), 90° gebündelt.
Das Vorschaltgerät ist in einem Gehäuse , spritzwassergeschützt auf der Leuchte untergebracht.
Der Kühlkörper besteht aus eloxiertem Aluminium. Es wird passiv gekühlt. Durchmesser 32 cm.
Höhe: 100 W = 38 cm, 200 W = 48 cm. Die Leuchte kann an einer Kette aufgehängt oder mit dem
Haltebügel angeschraubt werden.
2. Auspacken
Prüfen Sie die Leuchte nach dem Auspacken auf etwaige Beschädigungen. Bei Beanstandungen wenden Sie sich bitte unverzüglich an Ihren Fachhändler.
Lieferumfang:
•
Leuchte LEDspot mit Haltebügel und zentraler Öse für Kettenaufhängung
3. Sicherheitshinweise
•
Die Leuchte ist keine Aquarienabdeckung und darf nur über dem Aquarium montiert werden. Bei der Befestigung über dem Aquarium darf der Mindestabstand zwischen Leuchte und
Wasseroberfläche 30 cm nicht unterschreiten.
•
Bei Betrieb kann das Gehäuse sehr heiß werden: Vorsicht bei Berührung!
Zur Reinigung trennen Sie die Leuchte vollständig vom Netz und lassen sie abkühlen. Anschließend hängen Sie die Leuchte ab.
•
Bei der Reinigung achten Sie darauf, dass keine Feuchtigkeit in das Innere der Leuchte gelangt!
•
Achten Sie auf einen ausreichenden Wärmeaustausch! Die Leuchte darf nicht hinter
Verkleidungen oder in Abdeckungen montiert werden.
Unzureichende Lüftung führt zu
Überhitzung der Leuchte und Schädigung der elektrischen Bauteile.
•
Unternehmen Sie keine eigenen Reparaturversuche, sondern schicken Sie die Leuchte zur
Prüfung, ggfs. mit einer Mängelbeschreibung, ein. Auch defekte LED Chips können nur vom
Hersteller getauscht werden.
•
Bei allen Arbeiten an der Leuchte unbedingt Netzstecker ziehen.
4. Installation
Die Leuchte wird mit der Öse an einer Kette an der Decke befestigt oder mit dem Haltebügel angeschraubt.
4.1. Lampenmontage/Lampenwechsel
Defekte LED Chips können nur vom Hersteller getauscht werden.
Elektrischer Anschluss:
Der LEDspot kann zur Automatisierung auch an eine Schaltuhr oder einen PWM Timer angeschlossen werden, oder über 0 – 10 V angesteuert werden. Ein Netzstecker ist im
Lieferumfang nicht enthalten. Das Kabel für den Netzanschluss und das Steuerkabel kommen oben aus der Leuchte und dürfen nicht verwechselt werden.
Arbeiten an der Leuchte sollten nur im stromlosen Zustand durchgeführt werden.
2
Abb. 1: Mean Well Vorschaltgerät für LEDspot 200 W (HLG-240H) und 100 W (HLG-120H)
5. Wartung und Pflege
Reinigen Sie die Scheibe im abgekühlten Zustand regelmäßig von Rückständen aus
Wasserspritzern und Verdunstung behutsam mit einem angefeuchteten Tuch. Verwenden Sie niemals zusätzliche Reinigungs- oder Scheuermittel!
6. Garantie
AB Aqua Medic GmbH gewährt eine 12-monatige Garantie ab Kaufdatum auf alle Material- und
Verarbeitungsfehler des Gerätes. Als Garantienachweis gilt der Original-Kaufbeleg. Während dieser
Zeit werden wir das Produkt kostenlos durch Einbau neuer oder erneuerter Teile instand setzen
(ausgenommen Frachtkosten). Im Fall, dass während oder nach Ablauf der Garantiezeit Probleme mit Ihrem Gerät auftreten, wenden Sie sich bitte an Ihren Fachhändler.
Diese Garantie gilt nur für den Erstkäufer. Sie deckt nur Material- und Verarbeitungsfehler, die bei bestimmungsgemäßem Gebrauch auftreten. Sie gilt nicht bei Schäden durch Transporte oder unsachgemäße Behandlung, Fahrlässigkeit, falschen Einbau sowie Eingriffen und Veränderungen, die von nicht autorisierten Stellen vorgenommen wurden.
AB Aqua Medic GmbH haftet nicht für Folgeschäden, die durch den Gebrauch des Gerätes entstehen.
AB Aqua Medic GmbH Gewerbepark 24 - 49143 Bissendorf/Germany
- Technische Änderungen vorbehalten – Stand 06/2013
3
LEDspot 100/200
Operation manual ENG
In purchasing this LEDspot , you have selected a top quality product. It has been specifically designed for aquarium use and has been tested by experts. High quality components and latest technology as well as modern design guarantee for enjoying your aquarium lighting for many years.
AB Aqua Medic GmbH
Gewerbepark 24, 49143 Bissendorf, Germany
___________________________________________________________________________________________
4
1. Technical Data
Line voltage: 230 Volt/50 Hz (if not stated otherwise on the ID-label).
Luminaires: 100 W resp. 200 W LED chips (12,000 Kelvin), 90° bundled.
The electronic ballast is placed in a splash-proofed body on the light. The cooling element is made of saltwater-resistant anodized aluminium. The cooling is done passively. Diametre: 32 cm. Height:
100 W = 38 cm, 200 W = 48 cm. The spotlight can be hung up with a chain or screwed on with the holder.
2. Unpacking
On unpacking, please check the light immediately for any damages. In case of any complaints, please contact your dealer directly.
Included in shipment:
•
LEDspot with holder and central loop for hanging up with chain
3. Safety advices
•
The light cannot be used as aquarium cover. It has to be mounted only above the aquarium. If it is mounted above the aquarium, the minimum distance between lighting and aquarium must be at least 30 cm.
•
The housing may become hot during operation. Be cautious when touching it! For cleaning, disconnect the light from the mains and let it cool down. Afterwards, take the light down.
•
When cleaning, take care that no humidity enters the interior of the light!
•
Pay attention to a sufficient thermal exchange. Keep the ventilation slits always free!
Do not mount the system in enclosures or behind panels.
Missing aeration may result in overheating and damage the electrical components.
•
Do not try to repair the light (LEDs, electronic parts). Please send it in for checking, preferably with a list of defects. Also, broken LED chips can be exchanged only by the manufacturer.
•
When working on the light, always pull all power plugs.
4. Installation
The light can be hung up on the central loop with a chain on the ceiling or can be screwed on with the holder.
4.1. Assembling/changing the LED chips
Broken LED chips can be exchanged only by the manufacturer.
Electric connection:
The
LEDspot
can be connected to a timeswitch or a PWM timer if automatic operation is desired or can be controlled by 0 – 10 V.
A power plug is not included. The cable for the power supply and the control cable come out of the light from above and must not be mixed up.
When working on the light, always pull all power plugs!
5
Pict. 1: Mean Well electronic ballast for LEDspot 200 W (HLG-240H) and 100 W (HLG-
120H)
5. Maintenance and Care
Clean the filter glass regularly (caution: let it cool down first!) from residues of water splashes and evaporation with a moistened cloth. Never use additional cleansing agents!
6
6. Warranty
Should any defect in material or workmanship be found within 12 months of the date of purchase
AB Aqua Medic GmbH undertakes to repair or, at our option, replace the defective part free of charge – always provided the product has been installed correctly, is used for the purpose that was intended by us, is used in accordance with the operating instructions and is returned to us carriage paid. The warranty term is not applicable on the all consumable products.
Proof of Purchase is required by presentation of an original invoice or receipt indicating the dealer’s name, the model number and date of purchase, or a Guarantee Card if appropriate. This warranty may not apply if any model or production number has been altered, deleted or removed, unauthorised persons or organisations have executed repairs, modifications or alterations, or damage is caused by accident, misuse or neglect. We regret we are unable to accept any liability for any consequential loss. Please note that the product is not defective under the terms of this warranty where the product, or any of its component parts, was not originally designed and / or manufactured for the market in which it is used. These statements do not affect your statutory rights as a customer.
If your AB Aqua Medic GmbH product does not appear to be working correctly or appears to be defective please contact your dealer in the first instance.
Before calling your dealer please ensure you have read and understood the operating instructions.
If you have any questions your dealer cannot answer please contact us.
Our policy is one of continual technical improvement and we reserve the right to modify and adjust the specification of our products without prior notification.