1. Allgemeines.............................. 2

2. Wichtige Hinweise vorab.......... 2

3. Kodierung................................. 2

4. Inbetriebnahme ........................ 3

5. Garantie ................................... 3

6. Technische Daten .................... 3

13. Anschlussbeispiele / Conn. Ex. 8

3931305/2014.15/E

Table of Contents

7. General Information ................. 5

8. Important Notes in Advance ..... 5

9. Coding ...................................... 5

10. Putting into Service .................. 6

11. Guarantee ................................ 6

12. Technical Data ......................... 6

13. Anschlussbeispiele / Conn. Ex. 8

Doepke

1Inhaltsverzeichnis

Bedienungsanleitung

4-fach Ein-/Ausgangsmodule DSS 4UR-N/-P

1. Allgemeines

Die DSS 4UR-N/-P sind Komponenten des Dupline Installationssystems mit vier Ein- und Ausgängen in Halbleiterausführung. Die Module ermöglichen u. a. die Einbindung von Standardtastern mit Rückmeldung. Durch ihre Bauform passen sie hinter Installationstaster in tiefe UP-

Schalterdosen.

Herkömmliche Taster und Schaltkontakte werden über drei beigelegte, 4-adrige und mit Aderendhülsen versehene Systemkabel an den DSS 4UR-N/-P betrieben. Dabei verhindert eine interne Tastsignalverlängerung Mehrfachschaltungen durch mögliches Tasterprellen.

Die Ausgänge der DSS 4UR-N/-P sind jeweils mit max. 50 mA belastbar. Grundsätzlich können beliebige Verbraucher verwendet werden; beim Einsatz von Glühlampen als Leuchtmittel, z.B. zur Rückmeldung, darf der Einschaltstrom die maximale Belastbarkeit jedoch nicht überschreiten. Deshalb - und wegen der längeren Lebensdauer - empfehlen wir den Einsatz von

LEDs.

Während beim DSS 4UR-P die elektrischen Verbraucher an 0 V DC betrieben werden, sind diese beim DSS 4UR-N an +24 V DC anzuschließen.

2. Wichtige Hinweise vorab

Zum Schutz von Leben und Komponenten, beachten Sie bitte folgende Sicherheitshinweise:

• Die Installation darf nur von einer autorisierten Fachkraft vorgenommen werden.

• Die 24 V DC-Spannungs- und Dupline-Signalversorgung muss aus Quellen erfolgen, die den Anforderungen für Schutzkleinspannung entsprechen, ebenso, wie die Installation diesen Anforderungen genügen muss (siehe hierzu die VDE 0100, Teil 410 sowie die

EN 50090-1-1). Andere Spannungen an den Signaleingängen können, trotz umfangreicher Schutzmaßnahmen im Gerät, zur Zerstörung des Gerätes und Gefährdung von Menschen führen. Weitere Hinweise finden Sie in der Dupline Planungshilfe.

• Die Ein- und Ausgänge der DSS 4UR-N/-P und die Module selbst, müssen durch dieselbe

Spannungsquelle versorgt werden.

3. Kodierung

Mit dem Handkodiergerät DHK 1 kann über die seitlich angebrachte Stiftleiste der Module jedem Kanal jede beliebige Adresse zwischen A1 und P8 zugeordnet werden. Die Aufteilung der

Kanäle ist wie folgt:

Kanal

1

2

3

4

Beschreibung

Eingangssignal 1 (I1)

Eingangssignal 2 (I2)

Eingangssignal 3 (I3)

Eingangssignal 4 (I4)

Kanal

5

6

7

8

Beschreibung

Ausgangssignal 1 (O1)

Ausgangssignal 2 (O2)

Ausgangssignal 3 (O3)

Ausgangssignal 4 (O4)

Kanäle, die nicht benötigt werden, sollten unkodiert bleiben. Die Kodierung der Module kann ohne Versorgungsspannung oder Dupline-Signal vorgenommen werden und erfolgt mithilfe

3931305/2014.15/E - Technische Änderungen vorbehalten!

2

Doepke des Flachstecker-Kodierkabel DKP 2. Auf richtige Polarität des Kodierkabels ist zu achten, eine Verpolung führt aber nicht zur Zerstörung. Die Kodierung bleibt dauerhaft erhalten, kann aber jederzeit überschrieben werden.

4. Inbetriebnahme

Bei der Installation ist das Anschlussschema zu beachten. Alle anzuschließenden Leitungen müssen spannungsfrei sein. Verbindungen zwischen dem Dupline-Signal und dem Erdpotenzial führen zu Störungen und sind nicht zulässig. Zudem ist auf die richtige Polarität des Dupline-Signals zu achten.

Die folgende Tabelle zeigt die Belegung der übrigen Anschlussleitungen:

Kabelsatz S1

Kabelsatz S2

Kabelsatz S3

1

2

3

4

3

4

1

2

3

4

Pin

1

2

Farbe gelb grün braun braun grün-schwarz gelb-schwarz blau-schwarz grau rot blau gelb grün

Das Anschlussdiagramm finden Sie im Kapitel 13 auf Seite 8 .

Signal

Betriebsspannung +24 V DC

Betriebsspannung +24 V DC

Betriebsspannung 0 V DC

Betriebsspannung 0 V DC

Eingangssignal 1 (I1)

Eingangssignal 2 (I2)

Eingangssignal 3 (I3)

Eingangssignal 4 (I4)

Ausgangssignal 1 (O1)

Ausgangssignal 2 (O2)

Ausgangssignal 3 (O3)

Ausgangssignal 4 (O4)

5. Garantie

Für fachgerecht montierte, unveränderte Geräte gilt ab Kauf durch den Endverbraucher die gesetzliche Gewährleistungsfrist. Die Gewährleistung bezieht sich nicht auf Transportschäden sowie Schäden, die durch Kurzschluss, Überlastung oder bestimmungswidrigen Gebrauch entstanden sind. Bei Fertigungs- und Materialfehlern, die innerhalb der Gewährleistungsfrist erkannt werden, leistet unser Werk kostenlos Reparatur oder

Ersatz. Der Gewährleistungsanspruch erlischt, wenn das Gerät unbefugt geöffnet wurde.

6. Technische Daten

Min.

Typ.

Max.

Dupline

Stromaufnahme

Eingangskanäle

Ausgangskanäle

750 µA

4

4

3931305/2014.15/E - Technische Änderungen vorbehalten!

3

Doepke

Min.

Typ.

Max.

Eingänge

Art

Bemessungsspannung

Stromaufnahme je Eingang

Leitungslänge vom Bussignal entkoppelte Halbleitereingänge aus Kabelsatz (24 V DC)

1 mA

10 m

Ausgänge

Art

Bemessungsspannung

Belastbarkeit je Ausgang

Betriebsspannung

Nennbetriebsspannung

Eigenstromaufnahme

Anschlüsse

Klemmen

Kabelsatz

Halbleiterausgänge aus Kabelsatz (0 V DC / 24 V DC)

50 mA

21,5 V DC 24 V DC

5 mA

26,5 V DC

9 mA

Art 2-polige Federkraftklemmen mit doppelten Anschlüssen

Klemmbereich

Art für Bussignal und Spannungsversorgung

0,4 mm

0,8 mm

3 x 4 Leitungen LiYv mit Aderendhülsen

Querschnitt 0,25 mm²

Gehäuse

Art

Maße

Material

Allgemeine technische Daten

Umgebungstemperatur

Luftfeuchtigkeit

Schutzart

Schutzklasse

Bestellnummer, -bezeichnung

Schalterdosen-Einbaugehäuse

∅ 50,5 mm x 13,5 mm

Polyamid, glasfaserverstärkt

-10°C +45°C

Max. 85% (Betauung nicht zulässig)

IP20

III

09501241, 4-fach Ein-/Ausangsmodul DSS 4UR-N

09501242, 4-fach Ein-/Ausangsmodul DSS 4UR-P

Sollten Sie Fragen zu diesem Produkt oder zum Dupline-System haben, wenden Sie sich bitte an:

Doepke

Schaltgeräte GmbH

Stellmacherstraße 11

D-26506 Norden, Germany

Tel.: +49 (0) 4931 1806-0

Fax: +49 (0) 4931 1806-101

E-mail:

Internet: [email protected]

http://www.doepke.de

3931305/2014.15/E - Technische Änderungen vorbehalten!

4

Doepke

1Table of Contents

Operating Instructions

DSS 4UR-N/-P 4-way input/output modules

7. General Information

The DSS 4UR-N/-P are components of the Dupline installation system with four inputs and outputs in semi-conductor design. Amongst others, the devices allows the integration of conventional push-buttons with acknowledge signal to be linked to the system. Because of their compact design they can be fitted behind push-buttons in deep flush-mounted installation boxes.

Conventional push-buttons and potential-free switching contacts can be operated with the

DSS 4UR-N/-P via three 4-wire system cables supplied complete with end ferrules. An internal extended operating signal prevents any multiple switching occasioned by possible contact bounce.

The outputs of the DSS 4UR-N/-P are each designed for loads of max. 50 mA. Basically, any desired electrical consumers may be employed; however, the maximum loading capacity may not be exceeded when using incandescent lamps as indicator lights. For this reason - and because of the longer lifespan - we recommend the use of LEDs.

While the electrical consumers are driven at 0 V DC on DSS 4UR-P, they have to be connected to +24 V DC in case of DSS 4UR-N.

8. Important Notes in Advance

In order to protect both life and components, please observe the following safety instructions:

• Installation may only be carried out by authorised, trained technicians.

• The 24 V DC power and Dupline signal supply has to be delivered by sources, which have to be installed in accordance with the regulations governing protective low-voltage (see

VDE 0100, Part 410, or EN 50090-9-1) as well as the installation has to comply with these requirements. Even if extensive protective measures have been implemented in the device, other voltages at the signal inputs could result not only in the destruction of the device, but also endanger people. For further information please refer to the Dupline Planning

Aid.

• The in- and outputs of the DSS 4UR-N/-P and the modules themselves must be supplied by the same power source.

9. Coding

With the DHK 1 hand encoder each channel can be assigned any address between A1 and P8 via the pin strip at the side of the module. The allocation of the channels is as follows:

Channel

1

2

3

4

Description

Input signal 1 (I1)

Input signal 2 (I2)

Input signal 3 (I3)

Input signal 4 (I4)

Channel

5

6

7

8

Description

Output signal 1 (O1)

Output signal 2 (O2)

Output signal 3 (O3)

Output signal 4 (O4)

Channels which are not required should remain uncoded. Encoding the modules requires nei-

3931305/2014.15/E - The right to make technical changes reserved!

5

Doepke ther a supply voltage nor the Dupline signal and is carried out with the aid of the DKP 2 flatplug coding cable. Attention should be paid to the correct polarity of the coding cable; incorrect polarity will not, however, cause permanent damage.

Although the coding is permanently retained, it may always be overwritten.

10. Putting into Service

Observe the connection diagram when installing. All lines to be connected must be dead. Connections between the Dupline signal and earth potential will cause malfunctions and are not permissible. In addition, check for the correct polarity of the Dupline signal.

The following table illustrates the further connection configuration:

Cable Loom S1

Cable Loom S2

Cable Loom S3

5

6

3

4

7

8

1

2

3

4

Pin

1

2

Color yellow green brown brown green-black yellow-black blue-black grey red blue yellow green

The connection diagram is shown in Chapter 13 on page 8 .

Signal

Operating voltage +24 V DC

Operating voltage +24 V DC

Operating voltage 0 V DC

Operating voltage 0 V DC

Input signal signal 1 (I1)

Input signal signal 2 (I2)

Input signal signal 3 (I3)

Input signal signal 4 (I4)

Output signal 1 (O1)

Output signal 2 (O2)

Output signal 3 (O3)

Output signal 4 (O4)

11. Guarantee

All professionally installed, unaltered devices are covered by warranty during the statutory guarantee period from the day of purchase by the end user. The guarantee is not applicable to damage incurred during transport or caused by short-circuit, overloading or improper use. In the event of defects in workmanship or material, which are discovered within the guarantee period, the company will provide a repair or replacement free of charge. The guarantee will be rendered null and void if the device is opened without authorization.

12. Technical Data

Min.

Typ.

Max.

Dupline

Current input

Input channels

Output channels

750 µA

4

4

Inputs

Type Bus signal decoupled semi-conductor inputs

3931305/2014.15/E - The right to make technical changes reserved!

6

Doepke

Rated voltage

Current input per input

Length of line

Min.

Typ.

from cable loom (24 V DC)

Max.

1 mA

10 m

Outputs

Type

Operating Voltage

Rated operating voltage

Own current consumption

Terminals

Terminals

Cable Loom

21.5 VDC 24 VDC

5 mA

26.5 VDC

9 mA

Type spring-loaded terminals, 2-pole with double connections

Contact area 0.4 mm ∅ 0.8 mm ∅

Type 3 x 4 leads LiYv with end ferrules

Diameter 0.25 mm²

Housing

Rated operating voltage

Load capacity per output from cable loom (0 V DC / 24 V DC)

50 mA

Type

Dimensions

Material

General Technical Data

Operating temperature

Atm. humidity

Encl. protection type

Protection class

Order number, description semi-conductor outputs flush-mounted socket installation enclosure

50.5 x 13.5 (W x H in mm)

Polyamide, glass fibre reinforced

-10°C +45°C max. 85% (exposure to dew not permissible)

IP20

III

09 501 241, 4-way input/output module DSS 4UR-N

09 501 242, 4-way input/output module DSS 4UR-P

In case of queries concerning this product or the Dupline system please contact:

Doepke

Schaltgeräte GmbH

Stellmacherstraße 11

D-26506 Norden, Germany

Tel.: +49 (0) 4931 1806-0

Fax: +49 (0) 4931 1806-101

E-mail:

Internet: [email protected]

http://www.doepke.de

3931305/2014.15/E - The right to make technical changes reserved!

7

Doepke

13. Anschlussbeispiele / Conn. Ex.

8 3931305/2014.15/E - The right to make technical changes reserved!

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

advertisement