INSTALLATION GUIDE GUIDA ALL’INSTALLAZIONE INSTALLATIONSANLEITUNG NOTICE D’INSTALLATION GUÍA PARA LA INSTALACIÓN GUIA DE INSTALAÇÃO D812M • 230 Vac control unit with inverter • 230 Vac for three-phase motors with delta connections Vers. firmware 2049 1 3 4 5 6 7 D812M 24 25 26 27 12 13 14 15 16 17 18 19 20 8 9 10 11 88:88 1 2 D-MNL0D812M 21-09-2021 - Rev.05 2 21 22 23 28 29 30 IT - Istruzioni originali 2002/95/EC Signal light 230 Vac For the connection of a 12 Vac lamp with or without flashing card: See the Page n° 12 230 Vac automatic switch 10/16A 1 F1 10 A 2 3 4 5 6 7 D812M TEST TEST AUXILIARY 12 ÷ 14 Vac OUTPUT N.U. LED WARNING N.U. PEDESTRIAN COMUN LED POWER ON F2 1,6 A 8 9 10 11 24 25 26 27 88:88 S. TEMP. MF1 N.A. 1 2 Radio Connector CHIUDE AP/CH SICUREZZA STOP FOTO FCC FCA MF3 APRE MF2 MF1 MF2 MF3 Three-phase output for three-phase motors and “delta“ connections N.C. P3 28 29 30 - N.C. * TX N.A. + N.A. Connect this point to terminal no. 8 for the photo-test. Otherwise connect it to the terminal board no. 10 Photocells working in closing - N.A. + * P2 FCA FCC STOP PHOTO SAFETY OPRN CLOSE OP/CL SAFETY EDGE COMUN COMUN AERIAL 12 13 14 15 16 17 18 19 20 21 22 23 P1 RX OUT 2 Foreword This manual provides all the specific information you need to familiarize yourself with and correctly operate your unit. Read it very carefully when you purchase the instrument and consult it whenever you have doubts regarding use and before performing any maintenance operations. Nologo has the right to modify the product without previous notice. Environmental protection measures Information regarding the environment for customers within the European Union. European Directive EC 2002/96 requires that units bearing this symbol on the unit and/or on the packaging be disposed of separately from undifferentiated urban wastes. The symbol indicates that the product must not be disposed of with the normal household wastes. The owner is responsible for disposing of this product and other electrical and electronic equipment through specific waste collection facilities indicated by the government or local public agencies. Correct disposal and recycling help prevent any potentially negative impact on the environment and human health. To receive more detailed information regarding disposal of your unit, we recommend that you contact the competent public agencies, the waste collection. Piccola legenda LSO or FCA Open limit switch LSC or FCC Close limit switch OP/CL Control to drive the gate INDEX Par. Desricption 1 Scheme of the control unit Pag. 6 1.1 Description of the electrical connections 8 2 Use and functions of the control panel 9 2.1 State of the control unit 9 2.2 Settings and parameters 9 2.3 Example how to use the MENU and information 2.4 Set up a password for programming 10 2.5 Display the number of cycles and the speed of the motor 11 2.6 Desactivation of the cycle when the control panel wil be turned on 11 9 3 Installation of the control unit 12 3.1 Connection of the TENSION and MOTOR 12 3.2 Connection of the lamp 230 Vac or 12 Vac 12 3.3 Pre-flashing time 12 3.4 Connection of the Aerial 13 3.5 STOP connection 13 3.6 Connection of the 8k2 safety edge or N.C. 13 3.7 Connection of the Open and Close limit switch 13 3.8 The connection of PEDESTRIAN or OP/CL 14 3.9 Connection of the PHOTOCELL (only when closing) 14 3.10 Connection of the PHOTOCELL (activated when closing) with TEST 15 15 4 ACTIVATE the single OUTPUTS 5 Operating modes and adjustements 16 5.1 Logic of functions 16 5.2 Working time 17 5.3 Set SPEED and ACCELERATION 18 5.4 SCHEME relation between SPEED and FRQUENCY of the motor 19 in sliding units: control partial opening (alternate current) alternating voltage (discrete current) direct voltage 6 RESET of the control unit and restore of factory default settings 20 6.1 Restore factory settings 20 6.2 SAVE SET UP and CHECK of the parameters 20 7 LIST of the FUNCTIONS 21 NC normally closed 8 Problems 25 NA o NO normally open 9 Note 26 Isolated contact 10 Declaration of CE conformity 27 isolated from power supply PEDESTRIAN Vac Vdc 3 Safety precautions We remind that the installations of gates and automatic doors must be executed from qualified personnels according to the norms. Before installing check the strength and mechanic part of the gate or door, check that the mechanical stops are suitable to stop immediatelly the cycle of the gate or door even in case of faulty limit switches or during the manual cycle. For your security we recommend to install a STOP switch when activated it stops immediatelly the gate. The switch has a N.C. opening in case is activated (as shown in par. no. 3.5) Symbols and warning Dangerous Damage This is a warning and if it is not respec it can provoque material damage For safety reasons, protect your face during the connection Device under tension Read carefully the operating manual The installation should be done only from professional installer Read carefully this manul before installation and keep it for the future Dangerous for overheated surface Network filter for CE norms FILTER-S12 Option for CE Norms 4 Type of installation The control board D812M can be used for Industrial rapid doors and for sliding automation with threephase motors (delta connection) up to 2 Hp with ventilation systems. Sliding automation Check the software version and compatibility with the operating manual When the control unit is turn on, you can see 4 numbers in the display. This is the software number. We suggest to check this number with the version on the manual. (see pic). CODE 2049 GUIDA ALL’INSTALLAZIONE INSTALLATION GUIDE INSTALLATIONSANLEITUNG NOTICE D’INSTALLATION GUÍA PARA LA INSTALACIÓN GUIA DE INSTALAÇÃO D812M Vers. firmware 2049 1 Vers. firmware 1850 Check that the number on the display correspond to the firmware on the operating manual 24 25 26 12 13 14 15 16 17 18 19 20 3 4 5 6 7 27 8 9 10 11 88:88 21 22 23 28 29 30 IT - Istruzioni originali 1 5 2 D812M 1 2 D-MNL0D812M 02-03-2020 - Rev.04 ! • Centrale Inverter 230Vac • Per motori trifase 230Vac 2002/95/EC 1. Scheme of the control unit LED POWER ON Indicates the network power WARNING! We remind you that the safety devices, accessories should be installed when the control unit is not powered. 1 F1 10 A 2 3 4 5 6 7 LED WARNING LED POWER ON F2 1,6 A D812M 8 9 10 11 24 25 26 27 88:88 S. TEMP. MF1 1 2 12 13 14 15 16 17 18 19 20 21 22 23 P1 P2 P3 Set the control unit DIP not used JP1 Connector for temperature sensor F1 Fuses protection motor and power: 10A F2 Fused protection terminal boards (4, 5): 1.6A Radio Connector CHIUDE AP/CH SICUREZZA STOP FOTO FCC FCA MF3 APRE MF2 P1 P2 P3 28 29 30 MF1-2-3 Three-phases output for 230Vac motors delta connection LED WARNING Indicates that the capacitors are still charged, before removing the control unit wait for the LED to go off. The red led in the input LSO-LSC-STOP-PHOTO-SAFETY are always lit on The green led in the inputs OPEN-CLOSE-OP/CL are normally lit off LSO LSC STOP PHOTO SAFETY OPEN CLOSE OP/CL WARNING: If the inputs are desactivated from display with S13, S14, S15, S16, S17 red leds are 6 switched off NETWORK FILTER 1 F1 10 A 2 3 4 5 6 7 F2 1,6 A LED WARNING LED POWER ON Recommended wiring diagram D812M 8 9 10 11 24 25 26 27 88:88 S. TEMP. MF1 1 2 12 13 14 15 16 17 18 19 20 21 22 23 Radio Connector CHIUDE AP/CH SICUREZZA STOP FOTO FCC FCA MF3 APRE MF2 P1 P2 P3 28 29 30 fILTER RINg CABLE MOTOR OUTPUT 1 TURN ELECTRICAL gROUND BAR shielded CABLE ENgINE MOTOR TERMINAL BOARD MOTOR 7 1.1 Description of the electrical connections In case of long sections of cables (> 20 m) for N.O./N.C. controls (ex. OPEN/CLOSE, STOP, PEDESTRIAN, etc.), in order to avoid gate malfunctions, it will be necessary to uncouple the various controls using RELAYS or using our 750T-RELE device. Earth 230 Vac (N) 1 2 Earth 230 Vac 50Hz, power supply, neutral 230 Vac (L) 3 230 Vac 50Hz, power supply, phase Signal light 4 Signal light 5 230 Vac Signal light Max power 40 W 6 For the connection of a 12 Vac lamp or 230Vac signal ligth: See the par 3.2, page number 12 7 Test 8 Test 9 Out 12 Vac 10 Clean contact for PHOTOCELL TEST Clean contact for TEST 800mA auxiliary 12÷14 Vac output Out 12 Vac 11 800mA auxiliary 12÷14 Vac output LSO LSC Stop Photo A Safety edge Open Close OP/CL Costa Common Common 12 13 14 15 16 17 18 19 20 21 22 Open limit switch Closing limit switch STOP Photo-A closing N.C. contact (see S17 setting) OPEN CLOSE OPEN / CLOSE input SAFETY edge - NC / 8k2 contact Common Services Safeties Antenna Socks / Common-Services-Safeties + Antenna 23 + Antenna N.U. 24 N.U. 25 Pedestrian 26 NOT USED NOT USED Partial opening / Interlock input Common 27 Out + 12 Vdc 28 Out - 12 Vdc 29 N.U. 30 Common Services Safeties Output + 12Vdc 60mA Output - 12Vdc 60mA NOT USED 8 2. Use and functions of the control panel D812M has a display for a simple and fast programming. The menu has been designed for a clear and fast set up of the working time and the logic of the control unit. You can set up the control unit only when the door is closed. 2.1 State of the control unit If no button is pressed, the display shows the position of the automation and the temperature value of the IGBT heat sink. P.Fcc t23c In this case the door is with closing limit switch and that the heat temperature is 23°C. 2.2. Settings and parameters P1 P2 - UP ACCESS TO ThE fUNCTIONS Press P1 when the gate is closed - t- L- E- P3 - DOWN P1 - OK SELECTION Of ThE LETTER ADJUSTMENT Press button P2 and P3 to select the group and press P1 to confirm. Set up T Set up of the Time programming Set up L Set up of the programm (Speed, power...) - S- r- Set up S Logic of the control unit Set up R Activation of the outputs Displays information about the control unit Set up E Back to the standard functions + P2 - UP P3 - DOWN P2 P1 - OK SELECTION OF NUMBER SET UP Press P2 and P3 to select the set up Press P1 to confirm P3 gO BACk To go back to the previous group press P2 and P3 SELf-RESET If the control unit is not used for more than one minute, the control unit go out from the programming saving programs and all changes. 2.3. Example how to use the MENU and information You can read the information through a display: you can read if it is working properly, the manoeuvre counter and the sink temperature. Some information can be shown only on the R function (see Chapter no.4) 9 - t- SYmBOlS P1 Access to the MENU Press and release P2 DOWN - L- S- r- Keep pressed Release 1st Press 2nd Press 3rd Press P1 confirm In the function R if you press P1, you can choose the group function: first select P2 and P3 and then confirm with P1. Now you can go to the function R07, R08, R09 and R10. DOWN r 07 r 08 P2 r 09 P3 UP r 10 Show the tension in the capacitors P1 P1 Show temperature of the IgBT P1 P1 P1 P1 Show the resistive value in the Safety edge input (terminal board no.20) Show the cycle counters (point indicated the thousands) P1 P1 2.4. Set up a password for programming To save all changes it is possible to select a password of 4 numbers. To activate this function make as follow: • Password activation: Press P1, P2 and P3 in the function S32 and then confirm with P1. 10 - t- P1 Access to the menu - S- P2 2nd press P1 confirm In the function S if you press P1, you can choose the group function: first select P2, now you can go to the function S32 and then confirm with P1. S 01 • INSERT PASSWORD Choose the first number with the buttons P2 and P3 then confirm with P1. The same procedure applies to the other digits. 0--P2 finished entering the 4 digit. Press P1 to confirm. To cancel press P1, within 10 seconds. Otherwise, the next access will be required the security code. S 32 Pay attention in case you forget the password it is not possible to enter in control board as well. P1 - OK • Deactivation of the password S 33 If you select the fucntion no. S33 you can cancel the password. Wait 10 seconds to confi rm the operation. P1 - OK 2.5. Display the number of cycles and the speed of the motor • Cycle counter • Motor speed Press P1 when the door is open, the display shows the SPEED of the MOTOR It is possible to show the number of cycles even pressing P3 (expressed in ten cycles) P1 P3 The counter counts up to 999’999 openings. The display shows the first 4 most significant digits. 344.2 If you read these number, it means that the installation has made 344200 cycles. 2.6. Desactivation of the cycle when the control panel wil be turned on When the tension has been interrupted and you turn on the control board again it will make a new cycle. To exclude this operation make as follow: P1 DESACTIVATE THE COMPLETE CYCLE Of ThE CYCLE fUNCTION WhEN ThE TENSION hAS BEEN INTERRUPTED: keep pressed P1 when turns on. 11 3. Installation of the control unit 3.1. Connection of the TENSION and MOTOR POWER SUPPLY 1 2 3 • The control unit is equipped with a network filter three-phase motor connection (no single-phase motor) We recommend: N 230 Vac L • Install an automatic switch 10/16A • Check the network power: 230 Vac: -5% +10% 3.2. Connection of the lamp 230 Vac or 12 Vac It is shown the connection of a 230V lamp with or without flashing card. 4 5 6 7 flashing light 230 Vac It is shown the connection of a 12 Vac lamp with or without flashing card. 10 11 6 7 flashing light 12 Vac • Set up of the lighting In case the lamp has no flashing card, set S12 in 1: S12 FLASHING 1 - Activated (standard) 0 - Deactivated • Lamp in pause time To activate the function lamp in pause TIME, set S05 as shown: S 05 LAMP IN PAUSE 1 - Activated 0 - Deactivated (standard) 3.3. Pre-flashing time It is possible to increase or reduce the time of pre-flashing when the door is closed or open, make as follow with T07 and T08: t 07 t 08 Pre-flashing time on opening From 0 to 10 s Standard value 0.5 s Pre-flashing time ON CLOSING From 0 to 10 s Standard value 2 s 12 3.4. Connection of the Aerial 20 21 22 23 In case the antenna is only a cable of 17cm for 433.92Mhz, connect it to the terminal board no. 23. 3.5. STOP connection Button: Stop until a new command Switch: it keep the automation stopped until a new command S 15 12 13 14 15 16 17 18 19 20 21 22 23 STOP 1 - Activated (Default) 0 - Deactivated The connection of the safety devices is prevued with a button or a normally closed contact More devices should be connected in parallel. 3.6. Connection of the 8k2 safety edge or N.C. contact Connect the safety edge at terminal board no. 20 and 21 S 22 S 38 12 13 14 15 16 17 18 19 20 21 22 23 SAFETY EDGE 0 - Deactivated 1 - Activated (Default) SAFETY EDGE contact 0 - NC contact (normally closed) (Default) 1 - 8K2 contact 3.7. Connection of the Open and Close limit switch 12 13 14 15 16 17 18 19 20 21 22 23 OPEN N.C. S 13 S 14 CLOSE N.C. LSO 1 - Activated (Default) 0 - Deactivated LSC 1 - Activated (Default) 0 - Deactivated If the input LSO & LSC is not used, set S13 & S14 in 0 limit switch 13 3.8. The connection of Pedestrian or OP/CL 12 13 14 15 16 17 18 19 20 21 22 23 OP/CL The connection of a OP/CL command can be done with a button or with a N.O. contact. When more devices are available, connect them in parallel. 24 25 26 27 PEDESTRIAN control The connection of Pedestrian can be done with a button or a normally open contact. It is possible to connect a timer in the terminal board no. 19 and 21 to program the opening time of the gates.The contact of the timer should be normally open (N.O.) and it should be closed for all the time the gate is open. If the conncection of opening command is available in the terminal board no 19, connect it in parallel. 3.9. Connection of the PHOTOCELL (only when closing) 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 The contact of the receiver should be: - Isolated (isolated from tensions) - Normally closed 0 Vac TX RX If the PHOTOCELL input is not used, S16 must be set to 0 12 Vac NC Contact 14 3.10. Connection of the PHOTOCELL (activated when closing) with TEST 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 0 Vac 12Vac TEST TX The TEST of the photo-beam works only if the photo-beams are installed properly. The control unit will check all connections before opening! RX In case the photo-beam are not working properlym the control unit will lit on for 5 seconds and the gate is not moving. If you go back to function without TEST, do the connection as in Par. 3.9 and put in 0 the S06 and S09 (deactivate the latter only if there are no other inputs connected to TEST) 12 Vac NC Contact To activate the TEST set 1 in the PHOTO-A: S 09 TEST in PHOTO OUTPUT 1 - Activated 0 - Deactivated (default) S 06 TEST in the INPUT safeties 1 - Activated 0 - Deactivated (default) 4. ACTIVATE the single OUTPUTS D812M can open and close separately and the outputs for lamps and test. This is useful in case you want to check the single outputs. - tP2 P1 Access to the functions SYmBOlS Press and release Keep pressed Release In the function R if you press P1, you can choose the subfunction group function: first select P2 and P3 and then confirm with P1. Now you can go to the function R01, R02, R03 ... 15 - L- S- r- P2 - 1° press P2 - 2° press P2 - 3° press P1 confirm r 01 DOWN r 02 P2 r 03 r 04 P3 r 05 UP r 06 r 11 P1 OPEN with set up acceleration P1 P1 CLOSE with set up acceleration P1 OPENINg with slow down P1 P1 CLOSINg with slow down P1 P1 Activate the LIghT P1 P1 P1 P1 ACTIVATE the TEST output ACTIVATE the BRAkE output P1 P1 5. Operating modes and adjustments 5.1. Logic of functions Imp. N° S 01 Functions Description 1 Signal Reverse By each START command inverts: OPEN-CLOSE It recloses automatically 2 Automatic The START command can open or recharge the pause time. It recloses automatically 3 Bistable function 4 Stable function with automatic reclosing after pause time 5 Signal reverse Same as function S01 - 1 + Dead-man function OPEN and CLOSE with “Dead-man function“ function 6 Collective use Same as function S01 - 2 + Dead-man function OPEN and CLOSE with “Dead-man function“ function By each START command it follows: open-stop-closestop-open... It doesn’t recloses automatically By each START command it opens-stops-closesstops-opens... It recloses automatically after pause time 16 7 Bistable function Same as function S01 - 3 + Dead-man function OPEN and CLOSE with “Dead-man function“ function S 02 1 Bistable function with automatic reclosing after pause time + Dead-man function Reclosing when turning on (Standard value 0) S 04 1 Photocell contact (Default 0) 8 S 07 T 18 1 Same as function S01 - 4 OPEN and CLOSE with “Dead-man function“ function Complete open and close. ONLY when the tension has been interrupted when the gate is open. Al passaggio rilevato dalle fotocellule, in apre se S07 è 0 imposta tempo di pausa a 2 s. Put S04 in 1. When the following function is active on Close after photocell the passage detected by the photocells on opening, (Default 0) the control unit reverses the motor motion and closes. It is possible to activate the automation opening Automatic opening after the set time, from 1 to 99 minutes. (00 If the after the time set function is deactivated). Attention, choose a mode of (Default 00) operation with automatic reclosing. 5.2. Working time You can see how to program the control unit with T function: 0 s. 20 s. T01=20 s. Total opening time of the automation Opening 0s. T04=5s. 5s. Start of the deceleration in the closing manoeuvre 15s. 20s. T03=15s. Start of the deceleration in the opening manoeuvre SET DESCRIPTION UP Setting the total working time of the opening From the FCC closing limit switch to the FCA opening limit switch the time increases from 0s ÷ 20s. Vice versa, from the FCA opening limit switch to T 01 the FCC closing limit switch, the time decreases from 20s ÷ 0s (countdown). it is recommended to set the time T01 with a few extra seconds of work 17 Values accepted step da front 0,1 to 0,1 s 990 s STANDARD - seconds - 20,0 T 02 Setting the pedestrian opening time Setting the starting slowdown position on opening If we want the gate to slow down the last 5s, just set 15s on T03 and the gate will start to slow down from 15s to 20s. Ex.: T01 = 20s assumed slowdown time = 5s T 03 step da front 0,1 to 0,1 s 990 s 3,0 step da front 0,1 to 0,1 s 990 s 15,0 Setting the starting slowdown position on closing To set the slowdown on closing, the work time works as a countdown, so if we want the gate to step da front 0,1 to slow down the last 5s, just set 5s on T04 and the 0,1 s 990 s gate will start to slow down from 5s to 0s. Ex.: T04 = 5s When T01 reaches 5s from 20s, the slowdown starts. T 04 5,0 Extra time for limit switch search T 10 In order to avoid that, due to errors in counting the operating time, the motor cannot open or close completely, an extra limit switch search time can be set. We recommend setting at least 5 s as per DEFAULT step da 0,1s da 0,1 a 990s 5,0 ??? 5.3. Set SPEED and ACCELERATION Are now given the parameters that allow you to set SPEED, ACCELERATION and ABSORPTION: Set up Description Values accepted Default L 01 Minimum speed OPENING from 1 to 50 30 L 02 Minimum speed CLOSING from 1 to 50 30 L 03 Maximum speed OPENING from 1 to 120 80 L 04 Maximum speed CLOSING from 1 to 120 80 L 05 OPENING acceleration from 1 to 10 5 L 06 CLOSING acceleration from 1 to 10 5 L 07 OPENING deceleration from 0 to 10 5 L 08 CLOSING deceleration from 0 to 10 5 L 09 Motor absorption in case of STOP Ampere 9,0 L 10 Motor absorption in case of problems Ampere 12,0 L 11 Not used from 1 to 70 50 18 5.4. SCHEME relation between SPEED and FREQUENCY of the motor Here is the relation between speed and frequency of the motor: Speed setting FREQUENCY [Hz] 1 12 5 14.50 10 17.00 15 19.50 20 22.00 25 24.50 30 27.00 35 29.50 40 32.00 45 34.50 50 37.00 55 39.50 60 42.00 65 44.50 70 47.50 75 49.50 80 52.00 85 54.50 90 57.00 95 59.50 100 62.00 105 64.50 110 67.00 115 69.50 120 72.00 19 6. RESET of the control unit and restore of factory default settings The control unit allows the parameters to be reset to their DEFAULT value (see par. 6.1), and also allows you to recall parameters stored specifically for the operation of the sliding gates. 6.1. Restore factory settings Checking those paramenter of the parameters (Chapter no.7), yuo can look the set up during the RESET of the control unit. Select the paragraph S18 as shown: - t- - S- P2 2nd press P1 Access to the functions P1 confirm S 18 WARNINg: This operation cancel all settings P1 - OK Operation will be cancelled. Wait 10 seconds, otherwise, if you press P1 in 10 seconds, this operation will be cancelled. For standard values see table at pag no. 20 and following. 6.2. SAVE SET UP and CHECK of the PARAMETERS D812M has 2 memory slots saving all manually set up and you can check it again. See how to check the set up with functions S23, S24, S25, S26. Once all parameters are set up, it is possible to change. Thanks of the 2 memory slots, it is possible to save and check 2 differents set up. • MEMORIA 1 (slot 1) S 23 S 25 Press P1 Save all set up MEMORY 1 Press P1 Charge set up of MEMORY 1 • MEMORIA 2 (slot 2) S 24 S 26 20 Press P1 Save all set up MEMORY 2 Press P1 Charge set up of MEMORY 2 7. LIST of the FUNCTIONS D812M Group functions “T” SET DESCRIPTION UP step from 0,1 s step from 0,1 s step from 0,1 s step from 0,1 s step from 0,5 s step from 0,5 s step from 0,5 s step from 0,5 s VALUES STANDARD MEMO ACCEPTED - seconds from 0,1 to 20,0 s 990 s from 0,1 to 3,0 s 990 s from 0,1 to 15,0 s 990 s from 0,1 to 5,0 s 990 s from 2 to 2,0 s 127.5 s from 2 to 5,0 s 127.5 s from 2 to 0,5 s 127 s from 2 to 2,0 s 127 s step from 0,1 s from 0,1 to 990 s 5,0 s Stop the detection of input of the photo-beam. Not considered if S03 is set 1 step from 0,1 s from 0,1 to 990 s 0,5 s Time to stp to detecte the SAFETY EDEGE INPUT (terminal board. 16) step from 0,5 s from 0,1 to 2s 1,0 s step from 0,1 s from 0 to 2s 0,2 s step from 0,1 s step from 0,1 s step from 0,1 s from 0 to 2s from 0 to 3s from 0 to 3s T 01 Complete opening cycle time T 02 Partial opening time Setting the starting slowdown position on opening Setting the starting slowdown position on T 04 closing T 03 T 05 Automatic closing time T 06 Pause time for PARTIAL OPENING T 07 PRE-LIGHTING time by opening T 08 PRE-LIGHTING time by closing T 09 (Not used) T 10 Extra time for limit switch search T 11 T 12 Time block the check of the absorption of the T 13 motor when the gate is opening or closing Pause time of reverse of the direction of the T 14 motor T 15 STOP of the motor after detecting the LSO Time of delay of the motor when detecting the T 16 LSC Lead time on the release of the brake before T 17 starting the engine (in tenths of seconds) T 18 Automatic opening after the time set (00 If the function is deactivated) step from 1 min 21 0,1 s 0s 0s from 0 to 20 12 from 00 to 99 min 00 Group functions “L” SET UP VALUES ACCEPTED DESCRIPTION STANDARD - seconds - L 01 Minimum opening speed from 1 to 50 30 L 02 Minimum closing speed from 1 to 50 30 L 03 Maximum opening speed from 1 to 120 80 L 04 Maximum closing speed from 1 to 120 80 L 05 Opening acceleration from 1 a 10 5 L 06 Closing acceleration from 1 a 10 5 L 07 Opening deceleration from 0 to 10 5 L 08 Closing deceleration from 0 to 10 5 L 09 Maximum absorption of the motor to STOP the door in Ampere from 0,5 to 13 9,0 L 10 Maximum absorption of the motor in case of trouble in Ampere from 0,5 to 13 12,0 L 11 Power of the output BRAKE from 0 to 70 50 Group functions “S” SET DESCRIPTION UP VALUES ACCEPTED S 01 Logic of the motor: STANDARD MEMO from 1 to 8 4 Opening-closing cycle when the door is not closed 0 Off - 1 On 0 Deactivate the input PHOTO A S 03 after intervention of the slow down LSC 0 Deactivated - 1 Activated 0 0 Off - 1 On 0 1 - Fast reverse 2 - Collective use 3 - Bistable function 4 - Bistable function with automatic reclosing 5 - Fast reversing and “Dead’s man“ function 6 - Collective use and “Dead’s man function 7 - Bistable funciton and “Dead’s man“ function 8 - Bistable function with automatic reclosing and “Dead’s man“ function S 02 S 04 Photocell contact activation 22 S 05 Signal light in pause time 0 Off - 1 On 0 S 06 Activation TEST in the safeties inputs 0 Off - 1 On 0 S 07 Close after photocell 0 Off - 1 On 0 S 08 NOT USED Activate the TEST in the input S 09 PHOTOCELL Activate the Test in the SAFETY EDGE S 10 input leave on 2 2 0 Off - 1 On 0 0 Off - 1 On 0 S 11 Activate the TEST in the input STOP 0 Off - 1 On 0 0 Off - 1 On 1 S 13 Activate the input LSO 0 Off - 1 On 1 S 14 Activate the input LSC 0 Off - 1 On 1 S 15 Activate STOP input 0 Off - 1 On 1 S 16 Activate the PHOTOCELL by closing 0 Off - 1 On 1 S 17 Security 0 Off - 1 On 0 S 12 S 18 Activate the flashing in the signal light input Reset of the control unit at factory’s settings S 19 NOT USED S 20 Activated the input SWITCH for opening slowing down 0 Off - 1 On 0 S 21 Activate the input swicht for CLOSING slowing down 0 Off - 1 On 0 S 22 Activate the input for SAFETY EDGE (terminal 20-21) 0 Deactivated - 1 Activated 1 S 23 Copy set up of memory 1 S 24 Copy set up of memory 2 S 25 Charge the set up of memory 1 S 26 Charge the set up of memory 2 23 S 27 Charge the standard set up 1 S 28 Charge the standard set up 2 S 29 Charge the standard set up 3 S 30 Charge the standard set up 4 S 31 Charge the standard set up 5 Activate of a password to set up with a S 32 code of 4 numbers. Put the new code and let the time goes. You can deactive the access of the set S 33 up with a password Activation of the security closing S 34 after intervention of the edge (20-21) 0 deactivated - 1 activated 0 leave on 0 0 S 35 NOT USED S 36 NOT USED leave on 0 0 Integrated electric brake S 37 (activated for 2 seconds after motor stopping) 1= light acceleration 4 = heavy acceleration 5=neither acceleration nor braking 6= light braking 9= heavy braking 4 Safety edge - contact terminal board no.20-21 0: N.C. contact - 1: 8K2 contact 0 0 deactivated - 1 activated 0 S 38 S 39 Opening / Closing in case of emergency Group functions “R” SET UP DESCRIPTION R 01 Activate Opening until P1 has been released with acceleration set up R 02 Activate CLOSING until P1 has been released with acceleration set up R 03 Activate the OPENING until P1 has been released with slow down acceleration R 04 Activate CLOSING until P1 has been released with slow down set up R 05 Activate LIGHT/SIGNAL LIGHTH until P1 has been released R 06 Activate TEST output until P1 has been released R 07 Display the tension of the capacitors until P1 has been released R 08 Display temperature of the IGBT until P1 has been released R 09 R 10 Display the resistive value in the SAFETY EDGE input (terminal board no.20) until P1 has been released Display the number of cycles number of cycles until P1 has been released (point indicated the thousands) 24 R 11 Activate the brake output 8. Problems Here are listed some functions issue indicated in the display. You can see the causes and the procedure to solve the issue.. PROBLEM Er01 Er02 Er03 Er04 DESCRIPTION SOLUTION OVERVOLT on bus There is a tension of 240 Vac in the capacitors. Check the network tension. OVERCURRENT in the MOTOR The overcurrent level of programm L10 has been exceeded. If necessary increase the value. Tension in the capacitors too low The tension in the capacitors is too low. Check the network tension. Absorption at 1.5 A when the motor is not working The control unit has an absorption of more than 1,5A even if the motor is not working. Check the accessories and the motor. Er05 Er06 Security code not correct Code not correct. Try a new code. Exceeded temperature of the spendthrift IGBT Wait until the temperature in the spendthrift is reduced. Er07 Er17 Er27 Er67 Er77 Signal error of the encoder Check the encoder connections N.C. contact - Safety edge open Check terminals 20-21 (see paragraph 3.6) CO S.2 25 09 Note ................................................................................................. ................................................................................................. ................................................................................................. ................................................................................................. ................................................................................................. ................................................................................................. ................................................................................................ ................................................................................................. ................................................................................................. ................................................................................................. ................................................................................................. ................................................................................................. ................................................................................................. ................................................................................................. 26 10 Declaration of CE conformity (according to EC Directive 2006/42, Attachment II, part 1, ses. A) The undersigned Loris Virgilio Danieli, Administrator DECLARES THAT: Company:TAU S.r.l. Via Enrico Fermi, 43 Address: 36066 Sandrigo (VI) Italia Product’s name: D812M Centrale Inverter 230Vac THE PRODUCT COMPLIES with what is outlined in the European Community directive: 2006/42/CE EC DIRECTIVE 2006/42 ISSUED BY THE EUROPEAN PARLIAMENT AND COUNCIL on may 17, 2006 harmonizing the legislation of the member countries regarding machinery. Reference: Attachment II, part 1, ses. A (EC Declaration of Conformity issued by the manufacturer). THE PRODUCT COMPLIES with what is outlined in the European Community directives: 2014/35/CE DIRECTIVE 2014/35/EU OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 26 February 2014 on the harmonisation of the laws of the Member States relating to the making available on the market of electrical equipment designed for use within certain voltage limits. Reference to harmonized standards: EN 60335-1 2014/30/CE Reference to harmonized standards: EN 61000-6-2 DIRECTIVE 2014/30/EU OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 26 February 2014 on the harmonisation of the laws of the Member States relating to electromagnetic compatibility. EN 61000-6-3 with the essential requirements of article 3 of the following European Community Directive, for the use for which the product is designede IL PRODOTTO E’ CONFORME 2014/53/CE (RED) DIRECTIVE 2014/53/EU OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 16 April 2014 on the harmonisation of the laws of the Member States relating to the making available on the market of radio equipment Reference to harmonized standards: ETSI EN 300 220-3 ETSI EN 301 489-1 ETSI EN 301 489-3 The directive 2006/42/CE remind that it is not allowed the function of the product until the machine, for which the product is included, is not indentify and declared conformed to the 2006/42/CE directive. Sandrigo, 01/06/2017 The Administrator Loris Virgilio Danieli TAU S.r.l. Via Enrico Fermi, 43 36066 Sandrigo (VI) Italia Tel +39 0444 750190 Fax +39 0444 750376 [email protected] www.tauitalia.com 27 Via Enrico Fermi, 43 - 36066 Sandrigo (VI) - Italy Tel +39 0444 750190 - Fax +39 0444 750376 [email protected] - www.tauitalia.com 28
advertisement
Related manuals
advertisement