Avigilon H5A Explosion-Protected Bullet Camera Installation Guide
تبلیغات
تبلیغات
ENGLISH
MAXIMUS MVXHD
High-spec ex-proof HD camera in a compact design
M anual
B
EN English
- Instruction manual
MNGCMVXHDCAM_1813_EN 3
4 MNGCMVXHDCAM_1813_EN
1 About this manual
Read all the documentation supplied carefully before installing and using this unit. Keep the manual in a convenient place for future reference.
This document has been compiled and published using product descriptions and specifications available at the time of publication. The contents of this document and the specifications of the products discussed herein are subject to change without notice. Avigilon Corporation reserves the right to make any such changes without notice.
Neither Avigilon Corporation nor any of its affiliated companies: (1) guarantees the completeness or accuracy of the information contained in this document; or (2) is responsible for your use of, or reliance on, the information. Avigilon Corporation shall not be responsible for any losses or damages
(including consequential damages) caused by reliance on the information presented herein.
2 Notes on copyright and information on trademarks
The mentioned names of products or companies are trademarks or registered trademarks.
AVIGILON, the AVIGILON logo, and AVIGILON
CONTROL CENTER are trademarks of Avigilon
Corporation.
Other names or logos mentioned herein may be the trademarks of their respective owners.
The absence of the symbols ™ and ® in proximity to each trademark in this document or at all is not a disclaimer of ownership of the related trademark.
ONVIF® is a trademark of Onvif, Inc.
3 Identification
3.1 Product marking
See the label attached to the product.
1.1 Typographical conventions
DANGER!
High level hazard.
Risk of electric shock. Disconnect the power supply before proceeding with any operation, unless indicated otherwise.
CAUTION!
Medium level hazard.
This operation is very important for the system to function properly. Please read the procedure described very carefully and carry it out as instructed.
INFO
Description of system specifications.
We recommend reading this part carefully in order to understand the subsequent stages.
MNGCMVXHDCAM_1813_EN 5
6
4 Installation
CAUTION! Device installation and maintaining must be performed by specialist technical staff only.
The external multipolar cable shield
(armature) must be earthed.
All disconnected wires must be electrically isolated.
The product comes with a multipolar cable or a cable tail for coupling purposes. When installing the device with the multipolar cable, keep at least 250mm free space from the bottom of the housing to allow for the minimum curvature radius of the multipolar cable.
4.1 Range of use
For indoors and outdoors installation.
Installation temperature: from -40°C (-40°F) up to
+60°C (140°F).
Operating temperature:
• -40 °C to 55 °C (-40 °F to 131 °F), in enclosed space
• -40 °C to 60 °C (-40 °F to 140 °F), with ambient convection
Relative humidity: from 10% up to 95% (no condensation).
4.2 Connection of the power supply line
Electrical connections must be performed with the power supply disconnected and the circuit-breaker open.
When commencing installation make sure that the specifications for the power supply for the installation correspond with those required by the device.
Check that the power supply is adequately dimensioned.
The device can be provided with different power supply voltages. The power supply voltage is
indicated on the product identification label. (3.1
The multicore cable has the power and earth cables inside.
Perform the connections following the instructions reported in the table .
CONNECTION OF THE POWER SUPPLY LINE
Power supply 24Vac/ 24Vdc/ 12Vdc
Colour
Black 1 (+)
Terminals
L (Phase)
Black 2 (-)
Yellow/Green
N (Neutral)
Tab.
1
MNGCMVXHDCAM_1813_EN
4.3 Connection of the Ethernet cable
The Ethernet cable shield must always be earthed via the connector. Always use a shielded RJ45 connector.
Use of Ethernet cables with the following characteristics is highly recommended:
• STP (shielded)
• Category 5E (or higher)
The product can be directly connected to an Ethernet switch.
Carry out the connections as described in the table
(according to the standard specifications: TIA/EIA-
568-B).
5
6
3
4
7
8
1
2
CONNECTION OF THE ETHERNET CABLE
Pin number Cable color
Orange-White
Orange
Green-White
Blue
Blue-White
Green
Brown-White
Brown
Tab.
2
The example below shows a typical installation.
4.4 Signal cable connection
CAUTION! TNV-1 installation type. The installation is type TNV-1, do not connect it to SELV circuits.
SIGNAL CABLE CONNECTION
Colour Function
White
Yellow
Pink
Violet (blue, cable tail version)
Red (brown, cable tail version)
Green
Grey
RS-485 A (+)
RS-485 B (-)
Relay 1, Terminal A
Relay 1, Terminal B
Alarm/Digital input
GND/Common alarm
Reset
Tab.
3
4.4.1 Alarm and relay connections
The external relay and alarm cable shield must be earthed.
The unit is equipped with the alarms and relays
indicated in the table (Tab. 3, page 7).
4.4.1.1 Connecting an alarm with dry contact
In case of free contact alarm make the connection as shown in the figure.
dry contact
AL1 COM
Switch
Personal
Computer
Fig.
2 AL1: Alarm 1. COM: Common alarms.
The dry contact alarm can be NO (normally open) or
NC (normally closed).
Fig.
1
MNGCMVXHDCAM_1813_EN 7
8
4.4.1.2 Relays connection
The relays are usable with the specifications described below. Working voltage: up to 15Vac or 30Vdc. Current: 1A max. Use suitable cable sections with the following characteristics: from 0.25mm² (23AWG) up to 1.5mm² (15AWG).
Due to the absence of polarity, both terminals of the same relay can be connected either to alternating or direct current voltages.
4.5 Washing system connection
For further details on configuration and use, refer to the relative manual.
5 Switching on
The automatic pre-heating procedure (De-
Ice) activates for 2 hours if on device switch on an ambient temperature is detected under -10 °C (+14°F). The procedure is necessary to guarantee correct operation of the devices even at low temperatures.
The full functionality of the product is guaranteed from the following ambient temperature: -40°C.
Do not turn on the unit when the ambient temperature is lower than indicated: -40°C.
The unit is switched on by connecting the power supply.
To switch off the unit disconnect the power.
5.1 Before powering the product in an explosive atmosphere
Make sure that all parts are fastened down firmly and safely.
Make sure that the unit and other components of the installation are closed so that it is impossible to come into contact with live parts.
Make sure that the device has been connected to an earth link as described.
Ensure the rear cover plate is correctly closed.
Ensure the product is correctly closed.
Ensure that the sealing of cable entry systems (if any) has been performed properly and the time of glue hardening has been observed.
5.2 First start-up
Make sure that the unit and other components of the installation are closed so that it is impossible to come into contact with live parts.
Make sure that all parts are fastened down firmly and safely.
MNGCMVXHDCAM_1813_EN
6 Configuration
6.1 Default IP address
The unit is configured to obtain an IP address from a DHCP server.
The IP address acquired via DHCP is visible in the
DHCP server log file.
If the DHCP server is not available, the unit automatically configures itself with a self-generated
IP address in the 169.254.x.x/16 subnet. Configuring the IP address of the PC as belonging to the same subnet (example: IP address: 169.254.1.1, subnet mask: 255.255.0.0).
Use an ONVIF compliant VMS or the Avigilon™
Camera Configuration Tool to find the IP address of the device.
6.2 Web interface
Browsers supported (the latest version):
Microsoft Edge, Google Chrome, Mozilla
Firefox.
6.2.1 First access to the web pages
The first operation in configuring the device consists in connecting to the web interface.
To access the web interface of the product, simply use a browser to connect to http://ip_address.
On first access, the Home page will be displayed.
Additional information about setting up and using the device is available in the following guides:
• Web Interface User Guide — Avigilon High
Definition H4 and H5 IP Cameras
• Avigilon Camera Configuration Tool User Guide
• Designing a Site with Avigilon Video Analytics
• Avigilon Control Center™ Client User Guide
These guides are available on help.avigilon.com and on the Avigilon website: avigilon.com/support-anddownloads.
6.3 Inserting an SD Card
For instruction about opening and closing the camera, please refer to Manual A.
For onboard video storage capabilities, please insert an industrial grade microSD card into the slot as show
Fig.
3
MNGCMVXHDCAM_1813_EN 9
7 Maintenance
Read the product Manual A before performing any operation.
Please provide the device serial number when requesting any replacement parts.
7.1 Factory Default
It is possible to reset to the factory default settings.
Follow the procedure below:
• Power the unit. Wait for 3 minutes.
• Connect the signal cable grey and green wires (
• Wait for 3 minutes.
• Switch off the unit.
Disconnect the previously connected green and grey wires.
• Power the unit.
8 Information on disposal and recycling
The European Directive 2012/19/EU on Waste
Electrical and Electronic Equipment (WEEE) mandates that these devices should not be disposed of in the normal flow of municipal solid waste, but they should be collected separately in order to optimize the recovery stream and recycling of the materials that they contain and to reduce the impact on human health and the environment due to the presence of potentially hazardous substances.
The symbol of the crossed out bin is marked on all products to remember this.
The waste may be delivered to appropriate collection centers, or may be delivered free of charge to the distributor where you purchased the equipment at the time of purchase of a new equivalent or without obligation to a new purchase for equipment with size smaller than 25cm (9.8in).
For more information on proper disposal of these devices, you can contact the responsible public service.
10 MNGCMVXHDCAM_1813_EN
9 Troubleshooting
CAUSE
Contact an authorized support centre if the problems listed below persist or you have any other issues that are not described here.
Read the product Manual A before performing any operation.
PROBLEM
CAUSE
SOLUTION
SOLUTION
PROBLEM
CAUSE
SOLUTION
PROBLEM
CAUSE
SOLUTION
Video streaming is not visible.
Incorrect IP address settings.
Check the device IP address and the configuration of the computer network card.
Automatic preheating procedure (De-Ice) in progress.
Wait until the end of the preheating procedure. If the ambient temperature is too low the unit will remain blocked.
The wash system is blocked and does not respond to commands.
The wash system is not enabled.
Check the configuration of the settings.
The wash system settings are incorrect.
Wrong settings in the configuration.
Check the configuration of the settings.
10 Technical data
10.1 Cameras
Resolution: Full HD 1080p (1920x1080pixel)
Image Sensor: 1/2.8" Progressive Scan CMOS
Focal length: from 4.3mm (wide) up to 129mm (tele)
Zoom: 30x
Max Aperture: F1.6
Horizontal Angle of View Based on Aspect Ratio:(16:9)
2.3°-66°
Electronic Shutter Control: Automatic, Manual
White balance: Automatic, Manual
Wide Dynamic Range: 120dB
Exposure Control: Automatic, Manual, Priority (Iris
Priority, Shutter Priority), Brightness, Custom
De-fog: On/Off
Privacy Zones: Yes
Day/Night Control: Automatic, Manual
Flicker Control: 60Hz, 50Hz
Backlight Compensation: On/Off
MNGCMVXHDCAM_1813_EN 11
Headquarters Italy Videotec S.p.A.
Via Friuli, 6 - I-36015 Schio (VI) - Italy
Tel. +39 0445 697411 - Fax +39 0445 697414
Email: [email protected]
Asia Pacific Videotec (HK) Ltd
Flat 8, 19/F. On Dak Industrial Building, No. 2-6 Wah Sing Street
Kwai Chung, New Territories - Hong Kong
Tel. +852 2333 0601 - Fax +852 2311 0026
Email: [email protected]
France Videotec France SARL
Immeuble Le Montreal, 19bis Avenue du Québec, ZA de Courtaboeuf
91140 Villebon sur Yvette - France
Tel. +33 1 60491816 - Fax +33 1 69284736
Email: [email protected]
Americas Videotec Security, Inc.
Gateway Industrial Park, 35 Gateway Drive, Suite 100
Plattsburgh, NY 12901 - U.S.A.
Tel. +1 518 825 0020 - Fax +1 518 825 0022
Email: [email protected]
www.videotec.com
MNGCMVXHDCAM_1813_EN
دانلود
تبلیغات