Advertisement
Advertisement
©2005-2011 Dynojet Research, Inc. All Rights Reserved.
Pre-Installation Guide for Model 200i/250i, 200iP/250iP, 250iX, and 250iPX Motorcycle
Dynamometers
This manual is copyrighted by Dynojet Research, Inc., hereafter referred to as Dynojet, and all rights are reserved. This manual, and the software described in it, is furnished under license and may only be used or copied in accordance with the terms of such license. This manual is furnished for informational use only, is subject to change without notice, and should not be construed as a commitment by Dynojet. Dynojet assumes no responsibility or liability for any error or inaccuracies that may appear in this manual.
Except as permitted by such license, no part of this manual may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means, electronic, mechanical, recording, or otherwise, without the prior written permission of Dynojet.
The Dynojet logo is a trademark of Dynojet Research, Inc.
Any trademarks, trade names, service marks, or service names owned or registered by any other company and used in this guide are the property of their respective companies.
Dynojet Research, Inc., 2191 Mendenhall Drive, North Las Vegas, Nevada 89081, USA.
Printed in USA.
Part Number: 98129103 Version 03 (05/2011)
T
ABLE OF
C
ONTENTS
Warnings
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iii
Dyno Pre-Installation Information
Introduction
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Conventions Used In This Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Technical Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Your Dyno Room
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Setting Up a Dyno Room . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Specifications and Requirements
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Battery Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Compressed Air . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Computer Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Drill and Drill Bit Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Electrical Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Environmental Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Fire Suppression . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Forklift Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Phone and Internet Access . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Tie-Down Straps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Model 200i/250i Dynamometer
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Chassis Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Room Layout—Model 200i/250i Dyno . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Ground Hook Placement—Model 200i/250i Dyno . . . . . . . . . . . . . . . . . . . 12
Model 200iP/250iP Dynamometer
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Pit Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Chassis Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Room Layout—Model 200iP/250iP Dyno . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Model 250iX Dynamometer
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Chassis Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Room Layout—Model 250iX Dyno . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Pre-Installation Guide for Model 200i/250i, 200iP/250iP, 250iX, and 250iPX Motorcycle Dynamometers i
TA B L E O F C O N T E N T S
Model 250iPX Dynamometer
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Pit Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Chassis Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Room Layout—Model 250iPX Dyno . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Unpacking The Dyno
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Removing the Crate Top and Sides . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Locating the Installation Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Appendix A Red Head Anchor Installation
Installation
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A-2
Appendix B Power Requirements and Installation
Locations Using 60 Hz Power (North America and Japan)
. . . . . . . . . . . . B-2
Installing the Wall Receptacle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-3
Testing for Correct Voltages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-4
Replacing the Power Plug . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-5
Hard Wiring to the Building . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-5
Connecting the Dyno . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-6
Locations Using 50 Hz Power
(Locations other than North America and Japan)
. . . . . . . . . . . . . . . . . . . B-7
Installing the Wall Receptacle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-8
Testing for Correct Voltages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-9
Replacing the Power Plug . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-10
Hard Wiring to the Building . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-10
Connecting the Dyno . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-11
Index
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Index-i ii
Pre-Installation Guide for Model 200i/250i, 200iP/250iP, 250iX, and 250iPX Motorcycle Dynamometers
W
ARNINGS
Disclaimers
Dynojet Research, Inc. (Dynojet) makes no representation or warranties with respect to the contents hereof and specifically disclaims any implied warranties of merchantability for any particular purpose.
Dynojet reserves the right to revise this publication and to make changes from time to time in the content hereof without obligation of Dynojet to notify any person of such revision or changes.
Dynojet is not responsible for false operation due to unexpected dynamometer operation such as may be caused by static, software bugs, hardware failure, etc.
Dynojet is not responsible for damage resulting from improper installation of the dynamometer or from improper service rendered to the dynamometer. Dynojet is not responsible for damage incurred due to alteration of the dynamometer or components, use of unapproved parts, or abuse to the dynamometer.
Do not connect or disconnect cables or components on the dynamometer with the power on.
Always wear protective clothing, ear protection, and eye protection (goggles, safety glasses) when using and servicing the dynamometer.
Equipment Power Requirements
The dynamometer has specific power requirements. Connecting the dynamometer to the incorrect voltage will void the dynamometer warranty. Installation may require a licensed electrician.
Potentially Lethal Voltages
Components attached to and within the dynamometer operate with potentially lethal voltages. To provide the greatest assurance of safety, the AC power cord(s) must be disconnected from the power source before servicing electrical components or wiring. Disconnect all power cords before servicing electrical components for the greatest assurance of safety.
Pre-Installation Guide for Model 200i/250i, 200iP/250iP, 250iX, and 250iPX Motorcycle Dynamometers iii
W A R N I N G S
Electrostatic Discharge Precautions
Electrostatic Discharge
Electrostatic Discharge (ESD), or static shock, can damage electronic components within the dynamometer. The damage may occur at the time of an ESD occurrence, or the shock may degrade the component, resulting in a premature component failure later. To avoid ESD damage, always practice good ESD control precautions when servicing the dynamometer. Dynojet designs its dynamometers to be very tolerant of static shocks by the users, but the electronics are vulnerable when the electronics are exposed. ESD occurs as a result of a difference of potential between two objects when the two objects touch. Damage occurs as a result of the energy released when the discharge
(touch) occurs. The difference of potential can accumulate by as simple an action as a user moving across carpet or a seat. If that person’s energy is discharged directly to the electronics, the electronics can be damaged.
Precautions
To protect against ESD damage, you must eliminate the difference of potential before the electronics are handled. Touch the chassis of the dynamometer before touching any of the electronics. By touching the chassis, you discharge any static shocks to the chassis instead of to the electronics.
If you are holding a circuit board or dynamometer component in your hand when you approach the machine, touch the chassis of the dynamometer with your hand before installing the circuit board or component.
When handling a circuit board or component to someone, touch that person with your hand first, then hand them the component.
Always carry circuit boards in anti-static bags when the boards are exposed (removed from the dynamometer).
Battery Fire and Explosion Hazards
There is a danger of explosion if the battery is incorrectly replaced. Replace only with the same or equivalent type recommended by the manufacturer. Discard used batteries according to the manufacturer’s instructions.
Automotive Batteries
In operation, batteries generate and release flammable hydrogen gas. They must always be assumed to contain this gas which, if ignited by burning cigarette, naked flame or spark, may cause battery explosion with dispersion of casing fragments and corrosive liquid electrolyte. Carefully follow manufacturer's instructions for installation and service. Keep away all sources of gas ignition and do not allow metallic articles to simultaneously contact the negative and positive terminals of a battery.
Do not allow the positive and negative terminals to short-circuit. The dynamometer chassis is tied to the negative side of the battery. Do not short between the positive battery terminal or the starter connections to the chassis. In addition, make sure metal tools such as screw drivers, wrenches, and torque wrenches do not come in contact with the negative and positive terminals of the battery. Short circuiting the terminals of the battery can cause burn injuries, damage to the dynamometer, or trigger explosions.
Charging
Batteries being charged will generate and release flammable hydrogen gas. Charging space should be ventilated. Keep battery vent caps in position. Prohibit smoking and avoid creation of flames and sparks nearby.
Wear protective clothing, eye and face protection, when charging or handling batteries.
iv
Pre-Installation Guide for Model 200i/250i, 200iP/250iP, 250iX, and 250iPX Motorcycle Dynamometers
W A R N I N G S
Other Potential Hazards
The AC power outlet shall be installed near the equipment and it shall be easily accessible to allow for disconnect before service.
The dynamometer should be located in a well ventilated area. There is a carbon monoxide hazard with all internal combustion engines. Engine exhaust contains poisonous carbon monoxide gas. Breathing it could cause death.
Any dyno room design must incorporate sufficient exhaust extraction.
Always wear proper ear and eye protection when operating the dynamometer.
Never operate the dynamometer with the covers removed.
Never stand behind the dynamometer when in operation.
Never operate the dynamometer when there is excessive vibration or noise. Resolve these problems before proceeding.
Never fuel the vehicle on the dynamometer unless appropriate safety measures are taken.
Verify brake operation before beginning any dynamometer testing.
Verify the vehicle is properly secured to the dynamometer.
Never operate the blowers without the guards installed.
Exercise care with any dynamometer testing; portions of the dynamometer and vehicle may become hot.
As with any equipment using electricity and having moving parts, there are potential hazards. To use this dynamometer safely, the operator should become familiar with the instructions for operation of the dynamometer and always exercise care when using it.
Do not repair or replace any part of the dynamometer or attempt any servicing unless specifically recommended in published user-repair instructions that you understand and have the skills to carry out.
Version 3 Pre-Installation Guide for Model 200i/250i, 200iP/250iP, 250iX, and 250iPX Motorcycle Dynamometers v
D
YNO
P
RE
-I
NSTALLATION
I
NFORMATION
Thank you for your interest in Dynojet’s Motorcycle Dynamometers. Dynojet’s software and dynamometers will give you the power to get the maximum performance out of vehicles you evaluate. Whether you are new to the benefits of a chassis dynamometer or an experienced performance leader, the repeatability and diagnostic tools of WinPEP 7 software and a Dynojet dynamometer (dyno) will give you the professional results you are looking for.
This document is designed to help you set up your dyno room before your dyno arrives. To ensure safety and accuracy in the procedures, perform the procedures as they are described.
Document Part Number: 98129103
Version 3
Last Updated: 05-23-11
This chapter is divided into the following categories:
• Specifications and Requirements, page 4
• Model 200i/250i Dynamometer, page 7
• Model 200iP/250iP Dynamometer, page 13
• Model 250iX Dynamometer, page 17
• Model 250iPX Dynamometer, page 21
Pre-Installation Guide for Model 200i/250i, 200iP/250iP, 250iX, and 250iPX Motorcycle Dynamometers
1
D Y N O P R E - I N S T A L L A T I O N I N F O R M A T I O N
Introduction
INTRODUCTION
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Thank you for your interest Dynojet’s Motorcycle Dynamometers. Before receiving your dyno, please take a moment to read this guide for dyno specifications and requirements, WinPEP 7 requirements, and dyno room set-up.
C ONVENTIONS U SED I N T HIS M ANUAL
The conventions used in this manual are designed to protect both the user and the equipment.
example of convention description
The Caution icon indicates a potential hazard to the dynamometer equipment. Follow all procedures exactly as they are described and use care when performing all procedures.
The Warning icon indicates potential harm to the person performing a procedure and/or the dynamometer equipment.
T ECHNICAL S UPPORT
For assistance, please contact Dynojet Technical Support at 1-800-992-3525, e-mail
Dynojet at [email protected], or write to Dynojet at 2191 Mendenhall Drive,
North Las Vegas, NV 89081.
Visit us on the World Wide Web at www.dynojet.com where Dynojet provides state of the art technical support, on-line shopping, 3D visualizations, and press releases about our latest product lines.
2
Pre-Installation Guide for Model 200i/250i, 200iP/250iP, 250iX, and 250iPX Motorcycle Dynamometers
Version 3
D Y N O P R E - I N S T A L L A T I O N I N F O R M A T I O N
Your Dyno Room
YOUR DYNO ROOM
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
This section is not meant to imply that a dyno room is essential to repeatable results on a Dynojet dynamometer. However, a dyno room with an engine cooling intake fan, exhaust extraction, and noise reduction capabilities can add a new dimension to your shop.
S ETTING U P A D YNO R OOM
A proper dyno room design will help to ensure repeatable, accurate runs. A good dyno room should do the following:
• exhaust extraction
• minimize noise
• provide a controlled environment for testing
• provide a view window (safety glass) for customers
• be designed with safety in mind
Exhaust Extraction— Exhaust extraction is needed to remove exhaust gasses, especially carbon monoxide, from the dyno room. Carbon monoxide is potentially lethal to people if not removed from the room and will affect engine power when mixed with fresh air. Plans for exhaust extraction (P/N 73429201) are available from
Dynojet.
Engine exhaust contains poisonous carbon monoxide gas. Breathing it could cause death. Operate machine in well ventilated area.
Intake Air Fan— After building your dyno room, you will need to supply a cooling fan. The cooling fan supplies air to cool the vehicle’s engine while supplying fresh oxygen for you and your vehicle to breathe. It is a common misconception that you cannot tune a vehicle without a large fan simulating exact road conditions; however, a good cooling fan is the only requirement for consistent diagnostics and tuning. The installed fan should be at least 5200 CFM or determined by Industrial Noise Control.
Note: If the air flow rate coming into the dyno room is greater than the air flow rate leaving the dyno room, the room will become pressurized. A pressurized dyno room will make measured power misleading.
Fire Suppression— Always have adequate fire suppression or fire extinguishers in your dyno room.
Industrial Noise Control, Inc.— Industrial Noise Control, Inc. offers zinc-coated custom built steel rooms or standard rooms.
Pre-Installation Guide for Model 200i/250i, 200iP/250iP, 250iX, and 250iPX Motorcycle Dynamometers
3
D Y N O P R E - I N S T A L L A T I O N I N F O R M A T I O N
Specifications and Requirements
SPECIFICATIONS AND REQUIREMENTS
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
The following specifications and requirements apply to all motorcycle dynos in this manual. Take a moment to review the requirements and make sure you can provide what your dyno will need.
B ATTERY R EQUIREMENTS
A motorcycle starting system is included with your dyno. You will need to purchase an automotive battery locally to use this feature. The battery is also necessary to run the power carriage and wheel clamp options. The dyno is designed to carry a group 24 deep cycle series battery with a minimum of 600 cold cranking amps.
For more information on installing the battery, refer to the dynamometer installation guide included with your dyno.
C OMPRESSED A IR
The following requirements are needed for the optional air brake and/or the AFR-4 pump:
• regulator set to 65 psi max (450 kilopascal) for air brake
• 5 CFM minimum for AFR-4 pump
• air dryer
• shut off valve
• gauge on the regulator
• 1/4-inch NPT pipe thread connector (to attach air to the dyno), if air hose does not have a 3/8-inch inside diameter
C OMPUTER S PECIFICATIONS
You will need to provide a computer system to run the WinPEP software.
minimum system requirements
• Microsoft® Windows 2000/XP
• 800 MHz Processor
• 256 MB of available RAM
• one 9-pin COM port, two 9-pin COM ports for
Tuning Link
• 1024 x 768, 256 color monitor (XGA)
• 1.2 gigabyte hard drive
• 30 MB of available hard-disk space
• CD ROM
• printer, if hard copies are needed recommended systems requirements
• Microsoft® Windows 2000/XP
• 2.4 GHz Processor or greater
• 512 MB of available RAM or greater
• one 9-pin COM port, two 9-pin COM ports for
Tuning Link
• 1280 x 1024 256 color monitor (SXGA) or better
• 40 gigabyte hard drive
• 100 MB of available hard-disk space
• CD ROM
• printer, if hard copies are needed
4
Pre-Installation Guide for Model 200i/250i, 200iP/250iP, 250iX, and 250iPX Motorcycle Dynamometers
D Y N O P R E - I N S T A L L A T I O N I N F O R M A T I O N
Specifications and Requirements
D RILL AND D RILL B IT R EQUIREMENTS
You will need to provide a drill and drill bit capable of drilling holes in concrete. Refer to Appendix A for more information on installing Red Head Anchors.
• drill bit size: 1/2-inch
• minimum hole depth: 1 5/8-inch (41.2 mm)
E LECTRICAL R EQUIREMENTS
The dynamometer requires a dedicated electrical circuit for reliable and precise operation. No other loads should be plugged into this circuit and this circuit should be independent of the lighting in the room.
Note: You will need to provide an additional circuit for the computer and dyno electronics.
description
Power Requirements specifications
240v 30amp single phase circuit
Refer to Appendix B for power requirements and installation.
50 or 60 Hz Frequency
Voltage normal min./max
Current
Power Consumption
Power Cord length end wall receptacle (included with dyno)
Full Load Amperage (FLA)
240 VAC
215 VAC/245 VAC except Japan 195 VAC/245 VAC
30amps
7200 watts
P/N 76950401
3.048 m (10.00 ft.) twist-lock plug or three-pin IEC plug twist-lock four wire grounded 30A NEMA L14-30 or three-pin IEC grounded 30A
30A
Version 3 Pre-Installation Guide for Model 200i/250i, 200iP/250iP, 250iX, and 250iPX Motorcycle Dynamometers
5
D Y N O P R E - I N S T A L L A T I O N I N F O R M A T I O N
Specifications and Requirements
E NVIRONMENTAL R EQUIREMENTS description
Temperature operating min./max storage min./max
Humidity specifications
10°C/50°C (50°F/122°F)
0°C/60°C (32°F/140°F)
0 to 95% non-condensing
F IRE S UPPRESSION
Always have adequate fire suppression or fire extinguishers in your dyno room.
F ORKLIFT R EQUIREMENTS
You will need to provide equipment capable of lifting a minimum of 1,077 kg
(2,375 lb.) to lift the dyno off the crate and into position in your dyno room. You will need a pair of straps capable of supporting 1,077 kg (2,375 lb.) to attach to the dyno.
Dynojet recommends using single loop style straps.
P HONE AND I NTERNET A CCESS
Dynojet recommends you have a phone close to the dyno to call for assistance in an emergency. You may also wish to contact Dynojet to troubleshoot your dyno.
Internet access on your computer is desirable for contacting Dynojet and downloading new information and updates.
T IE -D OWN S TRAPS
Dynojet recommends using tie-down straps for securing the motorcycle on the dyno.
6
Pre-Installation Guide for Model 200i/250i, 200iP/250iP, 250iX, and 250iPX Motorcycle Dynamometers
D Y N O P R E - I N S T A L L A T I O N I N F O R M A T I O N
Model 200i/250i Dynamometer
MODEL 200I/250I DYNAMOMETER
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
The following specifications and requirements will help you set up your dyno area and verify you have the requirements necessary to operate your dyno safely.
C HASSIS S PECIFICATIONS description
Length with standard carriage with extended carriage with ramp in down position
Height to top of dyno cover to top of ramp in up position
Width model 200i model 250i ramp
Weight model 200i dyno/crated dyno model 250i dyno/crated dyno
Drum diameter width
Frame
Maximum Horsepower
Maximum Speed
Maximum Motorcycle Length (front of front wheel to center of rear wheel) standard carriage extended carriage
Remote Switches specifications allow 271.78 cm (107.00 in.) allow 322.58 cm (127.00 in.) add 167.64 cm (66.00 in.)
45.97 cm (18.10 in.)
154.94 cm (61.00 in.)
106.68 cm (42.00 in.)
179.60 cm (70.70 in.)
104.70 cm (41.22 in.)
725 kg (1,600 pounds)/771 kg (1,700 pounds)
1,077.28 kg (2,375 pounds)/1,133.98 kg (2,500 pounds)
45.72 cm (18.00 in.)
50.80 cm (20.00 in.) structural steel channel and angle
500 HP (373 KW)
200 MPH (322 KPH)
213 cm (84.00 in.)
256.54 cm (101.00 in.) remote software control
Version 3 Pre-Installation Guide for Model 200i/250i, 200iP/250iP, 250iX, and 250iPX Motorcycle Dynamometers
7
D Y N O P R E - I N S T A L L A T I O N I N F O R M A T I O N
Model 200i/250i Dynamometer
Figure 1: Model 200i Dyno Dimensions
8
Pre-Installation Guide for Model 200i/250i, 200iP/250iP, 250iX, and 250iPX Motorcycle Dynamometers
D Y N O P R E - I N S T A L L A T I O N I N F O R M A T I O N
Model 200i/250i Dynamometer
Figure 2: Model 250i Dyno Dimensions
Version 3 Pre-Installation Guide for Model 200i/250i, 200iP/250iP, 250iX, and 250iPX Motorcycle Dynamometers
9
D Y N O P R E - I N S T A L L A T I O N I N F O R M A T I O N
Model 200i/250i Dynamometer
R OOM L AYOUT —M ODEL 200 I /250 I D YNO
Use the following information to locate various dyno equipment, power outlets, compressed air, and properly set up your dyno room.
provide compressed air for the:
•optional air brake
•optional AFR ‐ 4 pump provide an outlet for dyno power
109.22 cm
(43.00 in.)*
MC135 minimum dimensions for standard carriage
76.20 cm (30.00 in.) extended carriage
127.00 cm (50.00 in.)
245.11 cm
(96.50 in.)
436.88 cm
(172.00 in.)*
55.88 cm
(22.00 in.)*
60.96 cm (24.00 in.)
104.70 cm (41.22 in.)
78.74 cm (31.00 in.)*
8.89 cm (3.50 in.)
121.92 cm
(48.00 in.)
284.48 cm
(112.00 in.)*
*Dimensions are given for reference only and will vary with room size.
48.26 cm (19.00 in.)*
Figure 3: Room Layout—Model 200i/250i Top View
10
Pre-Installation Guide for Model 200i/250i, 200iP/250iP, 250iX, and 250iPX Motorcycle Dynamometers
intake fan - 5200 CFM with speed control exhaust extraction fan - 5200CFM exhausts to outdoors exhaust extraction expansion box exhaust extraction muffler
D Y N O P R E - I N S T A L L A T I O N I N F O R M A T I O N
Model 200i/250i Dynamometer
Figure 4: Room Layout—Model 200i/250i Side View
Version 3 Pre-Installation Guide for Model 200i/250i, 200iP/250iP, 250iX, and 250iPX Motorcycle Dynamometers
11
D Y N O P R E - I N S T A L L A T I O N I N F O R M A T I O N
Model 200i/250i Dynamometer
G ROUND H OOK P LACEMENT —M ODEL 200 I /250 I D YNO
You may wish to install additional ground hooks (included with your dyno) for
securing the motorcycle. Using Figure 5 as a guide, place the ground hooks in a
location that works best for your dyno application.
1 Using the ground hook as a template, mark and drill each hole needed to secure the ground hooks to the floor.
2 Install the Red Head anchors. Refer to Appendix A for installation instructions.
3 Secure each ground hook to the floor using two 3/8-16 x 1-inch hex bolts, two
5/16-inch flat washers, and two 3/8” lock washers.
Figure 5: Ground Hook Placement—Model 200i/250i Dynos
12
Pre-Installation Guide for Model 200i/250i, 200iP/250iP, 250iX, and 250iPX Motorcycle Dynamometers
Version 3
D Y N O P R E - I N S T A L L A T I O N I N F O R M A T I O N
Model 200iP/250iP Dynamometer
MODEL 200IP/250IP DYNAMOMETER
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
The following specifications and requirements will help you set up your dyno area and verify you have met the requirements necessary to operate your dyno safely.
P IT S PECIFICATIONS
Before proceeding, take a moment to look over the pit dimensions and requirements for your in ground dyno. Refer to the pit dimensions (P/N 98229102) you received from your salesman for more detailed specifications.
Note: The pit must be provided with exhaust ventilation at a rate of not less than
1CFM per ft.
2
of floor area (26CFM for the 250iP pit) taken from a point 300 mm
(12 in.) off the floor of the pit at all times that the building is occupied or when vehicles are parked over this area.
C HASSIS S PECIFICATIONS description
Length with standard carriage specifications with extended carriage pit covers
Height from top of pit to drum guard allow 304.80 cm (120.00 in.) allow 355.60 cm (140.00 in.)
137.16 cm (54.00 in.) from top of pit to top of carriage from pit floor to top of dyno frame
Width model 200iP
5.40 cm (2.125 in.)
50.64 cm (16.00 in.)
45.72 - 46.67 cm (18.00 - 18.375 in.) model 250iP pit covers
Weight model 200iP drum module/crated dyno
105.03 cm (41.35 in.)
179.07 cm (70.50 in.)
208.28 cm (82.00 in.)
725 kg (1,600 pounds)/817 kg (1,800 pounds) model 250iP retarder module/crated dyno 953 kg (2,100 pounds)/1,043 kg (2,300 pounds)
Drum diameter width
Frame
Maximum Horsepower
45.72 cm (18.00 in.)
50.80 cm (20.00 in.) structural steel channel and angle
373 KW (500 HP)
322 KPH (200 MPH) Maximum Speed
Maximum Motorcycle Length (front of front wheel to center of rear wheel) standard carriage extended carriage
213.00 cm (84.00 in.)
256.54 cm (101.00 in.)
Pre-Installation Guide for Model 200i/250i, 200iP/250iP, 250iX, and 250iPX Motorcycle Dynamometers
13
D Y N O P R E - I N S T A L L A T I O N I N F O R M A T I O N
Model 200iP/250iP Dynamometer
Figure 6: Model 200iP/250iP Dyno Dimensions
Figure 7: Control Panel Interface Assembly Dimensions
14
Pre-Installation Guide for Model 200i/250i, 200iP/250iP, 250iX, and 250iPX Motorcycle Dynamometers
D Y N O P R E - I N S T A L L A T I O N I N F O R M A T I O N
Model 200iP/250iP Dynamometer
R OOM L AYOUT —M ODEL 200 I P/250 I P D YNO
Use the following information to locate the necessary dyno equipment, power outlets, compressed air, and properly set up your dyno room.
For more detailed information about the pit requirements, refer to the pit specifications (P/N 98229102) you received from your salesman.
Note: The pit must be provided with exhaust ventilation at a rate of not less than
1CFM per ft.
2
of floor area (26CFM for the 250iP pit) taken from a point 300 mm
(12 in.) off the floor of the pit at all times that the building is occupied or when vehicles are parked over this area.
284.48
cm (112.00
in.)* min.
dimension extended carriage
220.98
cm
(87.00
in.) min.
dimension standard carriage
177.39
cm
(69.84
in.)
31.09
cm
(12.24
in.)* extended carriage
365.76
cm
(144.00
in.)* extended carriage
436.88
cm
(172.00
in.)* standard carriage
320.04
cm
(126.00
in.)* standard carriage
345.44
cm
(136.00
in.)*
60.96
cm (24.00
in.) 60.33
cm (23.75
in.)* provide compressed air for the:
•optional air brake
•optional AFR ‐ 4 pump provide an outlet for dyno power
Pd186
29.84
cm (11.75
in.)*
121.92
cm
(48.00
in.)
*Dimensions are given for reference only and will vary with room size.
Figure 8: Room Layout—Model 200iP/250iP Top View
Version 3 Pre-Installation Guide for Model 200i/250i, 200iP/250iP, 250iX, and 250iPX Motorcycle Dynamometers
15
D Y N O P R E - I N S T A L L A T I O N I N F O R M A T I O N
Model 200iP/250iP Dynamometer intake fan - 5200 CFM with speed control exhaust extraction fan - 5200CFM exhausts to outdoors exhaust extraction expansion box exhaust extraction muffler
30.48 cm (12.00 in.) to
60.96 cm (24.00 in.)
PD187
10.16 cm (4.00 in.) to
102.87 cm (40.50 in.)
Figure 9: Room Layout—Model 200iP/250iP Side View
16
Pre-Installation Guide for Model 200i/250i, 200iP/250iP, 250iX, and 250iPX Motorcycle Dynamometers
D Y N O P R E - I N S T A L L A T I O N I N F O R M A T I O N
Model 250iX Dynamometer
MODEL 250IX DYNAMOMETER
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
The following specifications and requirements will help you set up your dyno area and verify you have the requirements necessary to operate your dyno safely.
C HASSIS S PECIFICATIONS description
Length with standard carriage with extended carriage with ramp in down position
Height to top of dyno cover
Width model 200iX model 250iX ramp
Weight model 200i dyno/crated dyno model 250i retarder module/crated
200iX/250iX drum module/crated
Drum diameter width diameter, 200iX/250iX width, 200iX/250iX
Frame
Maximum Horsepower
Maximum Speed
Maximum Motorcycle Length (front of front wheel to center of rear wheel) standard carriage extended carriage
Remote Switches specifications allow 271.78 cm (107.00 in.) allow 322.58 cm (127.00 in.) add 370.84 cm (146.00 in.)
45.97 cm (18.10 in.)
200.69 cm (79.00 in.)
274.32 cm (108.00 in.)
185.42 cm (73.00 in.)
725 kg (1,600 pounds)/771 kg (1,700 pounds)
953 kg (2,100 pounds)/1,089 kg (2,400 pounds)
136 kg (300 pounds)/363 kg (800 pounds)
45.72 cm (18.00 in.)
50.80 cm (20.00 in.)
45.72 cm (18.00 in.)
55.88 cm (22.00 in.) structural steel channel and angle
500 HP (373 KW)
200 MPH (322 KPH)
213 cm (84.00 in.)
256.54 cm (101.00 in.) remote software control
Version 3 Pre-Installation Guide for Model 200i/250i, 200iP/250iP, 250iX, and 250iPX Motorcycle Dynamometers
17
D Y N O P R E - I N S T A L L A T I O N I N F O R M A T I O N
Model 250iX Dynamometer
274.32 cm
(108.00 in)
KU033
370.84 cm
(146.00 in)
261.62 cm
(103.00 in)
203.20 cm
(80.00 in)
45.72 cm
(18.00 in)
Figure 10: Model 250iX Dyno Dimensions
200.66 cm
(79.00 in)
18
Pre-Installation Guide for Model 200i/250i, 200iP/250iP, 250iX, and 250iPX Motorcycle Dynamometers
D Y N O P R E - I N S T A L L A T I O N I N F O R M A T I O N
Model 250iX Dynamometer
KU070
R OOM L AYOUT —M ODEL 250 I X D YNO
Use the following information to locate various dyno equipment, power outlets, compressed air, and properly set up your dyno room.
provide compressed air for the:
•optional air brake
•optional AFR ‐ 4 pump provide an outlet for dyno power center intake fan with carriage minimum dimensions for standard carriage
76.20
cm (30.00
in.) extended carriage
127.00
cm (50.00
in.)
245.11
cm
(96.50
in.)
76.20
cm
(30.00
in.)*
360.68
cm
(142.00
in.)*
60.96
cm (24.00
in.)
185.42
cm (73.00
in.)
192.28
cm
(75.70
in.)*
198.12
cm (78.00
in.) minimum door width
426.72
cm
(168.00
in.)*
*Dimensions are given for reference only and will vary with room size.
Figure 11: Room Layout—Model 250iX Top View
6.35
cm (2.50
in.)
86.36
cm (34.00
in.)*
Version 3 Pre-Installation Guide for Model 200i/250i, 200iP/250iP, 250iX, and 250iPX Motorcycle Dynamometers
19
D Y N O P R E - I N S T A L L A T I O N I N F O R M A T I O N
Model 250iX Dynamometer intake fan - 5200 CFM with speed control exhaust extraction fan - 5200CFM exhausts to outdoors exhaust extraction expansion box exhaust extraction muffler
Figure 12: Room Layout—Model 250iX Side View
20
Pre-Installation Guide for Model 200i/250i, 200iP/250iP, 250iX, and 250iPX Motorcycle Dynamometers
Version 3
D Y N O P R E - I N S T A L L A T I O N I N F O R M A T I O N
Model 250iPX Dynamometer
MODEL 250IPX DYNAMOMETER
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
The following specifications and requirements will help you set up your dyno area and verify you have met the requirements necessary to operate your dyno safely.
P IT S PECIFICATIONS
Before proceeding, take a moment to look over the pit dimensions and requirements for your in ground dyno. Refer to the pit dimensions (P/N 98229104) you received from your salesman for more detailed specifications.
Note: The pit must be provided with exhaust ventilation at a rate of not less than
1CFM per ft.2 of floor area (26CFM for the 250iP pit) taken from a point 300 mm
(12 in.) off the floor of the pit at all times that the building is occupied or when vehicles are parked over this area.
C HASSIS S PECIFICATIONS description
Length with standard carriage with extended carriage iPX drum module pit covers
Height specifications allow 304.80 cm (120.00 in.) allow 355.60 cm (140.00 in.)
76.20 cm (30.00 in.)
137.16 cm (54.00 in.) from bottom of dyno to top of dyno from top of pit to drum guard from top of pit to top of tire carriage
Width
45.72-46.67 cm (18.00-18.38 in.)
5.40 cm (2.13 in.)
50.64 cm (16.00 in.) dyno with upgrade pit covers with eddy current brake
Weight model 200iP drum module/crated dyno
271.42 cm (106.86 in.)
310.29 cm (122.16 in.)
725 kg (1600 pounds)/817 kg (1800 pounds) model 250iP retarder module/crated dyno 953 kg (2100 pounds)/1,089 kg (2400 pounds)
200iPX/250iPX drum module/crated 136 kg (300 pounds)/363 kg (800 pounds)
Drum diameter width diameter, 200iPX/250iPX upgrade width, 200iPX/250iPX upgrade
Frame
Maximum Speed
Maximum Motorcycle Length (front of front wheel to center of rear wheel) standard carriage extended carriage
Remote Switches
45.72 cm (18.00 in.)
50.80 cm (20.00 in.)
45.72 cm (18.00 in.)
55.88 cm (22.00 in.) structural steel
322 KPH (200 MPH)
213.00 cm (84.00 in.)
256.54 cm (101.00 in.) remote software control
Pre-Installation Guide for Model 200i/250i, 200iP/250iP, 250iX, and 250iPX Motorcycle Dynamometers
21
D Y N O P R E - I N S T A L L A T I O N I N F O R M A T I O N
Model 250iPX Dynamometer
45.72 - 46.67 cm
(18.00 - 18.38 in.) standard carriage
304.80 cm (120.00 in.) extended carriage
355.60 cm (140.00 in.)
137.16 cm
(54.00 in.)
239.00 cm (91.10 in.) pit covers
310.29 cm (122.16 in.) including eddy current brake cover
271.42 cm
(106.86 in.)
Figure 13: Model 250iPX Dyno Dimensions
76.20 cm
(30.00 in.)
PD104
Figure 14: Control Panel Interface Assembly Dimensions
22
Pre-Installation Guide for Model 200i/250i, 200iP/250iP, 250iX, and 250iPX Motorcycle Dynamometers
D Y N O P R E - I N S T A L L A T I O N I N F O R M A T I O N
Model 250iPX Dynamometer
R OOM L AYOUT —M ODEL 250 I PX D YNO
Use the following information to locate the necessary dyno equipment, power outlets, compressed air, and properly set up your dyno room.
For more detailed information about the pit requirements, refer to the pit specifications (P/N 98229104) you received from your salesman.
Note: The pit must be provided with exhaust ventilation at a rate of not less than
1CFM per ft.
2
of floor area (26CFM for the 250iP pit) taken from a point 300 mm
(12 in.) off the floor of the pit at all times that the building is occupied or when vehicles are parked over this area.
365.76
cm (144.00
in.)* min.
dimensions for standard carriage
177.39
cm (69.84
in.) extended carriage
220.98
cm (87.00
in.)
30.48
cm
(12.00
in.)*
457.20
(180.00
standard carriage
320.04
cm (126.00
in.) extended carriage
365.76
cm (144.00
in.)
cm in.)*
60.96
cm (24.00
in.) 158.75
cm (62.50
in.)*
KU071 provide compressed air for the:
•optional air brake
•optional AFR ‐ 4 pump provide an outlet for dyno power
182.88
cm (72.00
in.)
40.64
*Dimensions are given for reference only and will vary with room size.
cm (16.00
in.)*
Figure 15: Room Layout—Model 250iPX Top View
Version 3 Pre-Installation Guide for Model 200i/250i, 200iP/250iP, 250iX, and 250iPX Motorcycle Dynamometers
23
D Y N O P R E - I N S T A L L A T I O N I N F O R M A T I O N
Model 250iPX Dynamometer intake fan - 5200 CFM with speed control exhaust extraction fan - 5200CFM exhausts to outdoors exhaust extraction expansion box exhaust extraction muffler
30.48 cm (12.00 in.) to
60.96 cm (24.00 in.)
PD188
10.16 cm (4.00 in.) to
102.87 cm (40.50 in.)
Figure 16: Room Layout—Model 250iPX Side View
24
Pre-Installation Guide for Model 200i/250i, 200iP/250iP, 250iX, and 250iPX Motorcycle Dynamometers
D Y N O P R E - I N S T A L L A T I O N I N F O R M A T I O N
Unpacking The Dyno
UNPACKING THE DYNO
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
When you receive your dyno, examine the exterior of the shipping container for any visible damage. If damage is detected at this stage, contact the shipper or Dynojet before proceeding with unpacking.
You will need to provide equipment capable of lifting and moving the dyno. Refer to
“Forklift Requirements” on page 6 for more information.
R EMOVING THE C RATE T OP AND S IDES
1 Move the crated dyno to a clear area near your dyno room.
2 Using a pry bar, or a large flat screwdriver, and a hammer, carefully remove the top and sides of the crate.
Note: At this point, you will want to inspect the exterior of the dyno for any indications of damage. Report any damage immediately.
L OCATING THE I NSTALLATION G UIDE
Your dynamometer installation and user guides are located in a manila envelope and secured to the top of the dyno.
dyno manual on top of dyno
Version 3
Figure 17: Locating the Installation Guide
Pre-Installation Guide for Model 200i/250i, 200iP/250iP, 250iX, and 250iPX Motorcycle Dynamometers
25
A P P E N D I X A
R
ED
H
EAD
A
NCHOR
I
NSTALLATION
This appendix contains instructions for installing the Red Head Multi-Set™II Anchors.
The anchors will be used to secure the dyno to concrete. To ensure safety and accuracy in the procedures, perform the procedures as they are described. Be sure to read and understand the warnings included in this appendix.
WARNINGS
Always wear safety glasses and other necessary protective devices or apparel when installing or working with anchors.
ITW Ramset/Red Head Multi-Set II Anchors are designed to operate properly only when installed with ITW Ramset/Red Head brand Setting Tools.
The use of a 24 to 40 ounce hammer is recommended for expanding Multi-Set II anchors.
The use of carbide drill bits manufactured with ANSI B94. 12-77 drill bit diameter requirements is recommended for installation of this anchor.
Not recommended for use in lightweight masonry material such as block or brick.
Use of core drills is not recommended to drill holes for use with this anchor.
Not recommended for use in new concrete which has not had sufficient time to cure.
Anchor spacing and edge distance requirements (anchor installation locations) are the responsibility of the engineer of record.
CONTACT INFORMATION FOR ITW RAMSET/RED HEAD
Contact ITW Ramset/Red Head at 1-630-350-0370, or 1300 North Michael Drive,
Wood Dale, IL 60191.
Pre-Installation Guide for Model 200i/250i, 200iP/250iP, 250iX, and 250iPX Motorcycle Dynamometers
A-1
A P P E N D I X A
Installation
INSTALLATION
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Use the table below to determine the catalog number, drill bit size, minimum hole depth, and setting tool catalog number.
catalog number
Carbon Steel
RM-38/RL-38 (9.5 mm) drill bit size
1/2-inch minimum hole depth
1 5/8-inch (41.2 mm) setting tool catalog number
RT-138
Use the following instructions to install the Red Head anchors.
1 Drill the hole in the concrete the same outside diameter as the anchor being used to any depth exceeding minimum embedment.
Figure A-1: Red Head Anchor—Drill the Hole
2 Insert the anchor.
anchor
Figure A-2: Red Head Anchor—Insert the Anchor
A-2
Pre-Installation Guide for Model 200i/250i, 200iP/250iP, 250iX, and 250iPX Motorcycle Dynamometers
R E D H E A D A N C H O R I N S T A L L A T I O N
Installation
3 Using a hammer, drive the anchor flush with the surface of the concrete, or below the surface if the hole depth exceeds minimum embedment.
Figure A-3: Red Head Anchor—Drive the Anchor Flush
4 Using a hammer, expand the anchor with the setting tool. The anchor is properly expanded when the shoulder of the setting tool is flush with the top of the anchor.
Note: Use only Ramset/Red Head setting tools to insure proper installtion.
setting tool
Figure A-4: Red Head Anchor—Expand the Anchor
Version 3 Pre-Installation Guide for Model 200i/250i, 200iP/250iP, 250iX, and 250iPX Motorcycle Dynamometers
A-3
A P P E N D I X B
P
OWER
R
EQUIREMENTS AND
I
NSTALLATION
Different countries have different standards for delivery of AC (alternating current) electricity to homes and buildings. The frequency (number of cycles per second) in
Hertz (Hz) varies from country to country.
North America typically uses 60 Hz power. Western Japan including the Osaka, Kyoto,
Nagoya, Hiroshima regions also uses 60 Hz power. Eastern Japan including the
Tokyo, Kawasaki, Sapporo, Yokohama, and Sendai regions uses 50 Hz power.
Many other countries, such as Germany, the Netherlands and most European Union countries have standardized on 50 Hz.
To ensure safety and accuracy in the procedures, perform the procedures as they are described.
This Appendix is divided into the following categories:
• Locations Using 60 Hz Power (North America and Japan), page B-2
• Locations Using 50 Hz Power (Locations other than North America and Japan), page B-7.
Pre-Installation Guide for Model 200i/250i, 200iP/250iP, 250iX, and 250iPX Motorcycle Dynamometers
B-1
A P P E N D I X B
Locations Using 60 Hz Power (North America and Japan)
LOCATIONS USING 60 HZ POWER (NORTH AMERICA AND JAPAN)
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
The following power requirements and instructions are for North America, much of
Japan, and other locations using 60 Hz power. All other locations should refer to the
instructions found in “Locations Using 50 Hz Power (Locations other than North
America and Japan)” on page B-7.
The model 200i/250i dynamometer requires a dedicated 240VAC single phase power outlet rated for 30A for proper operation. Failure to follow these instructions could result in personal injury or damage to the dyno.
Connecting the dyno to the incorrect voltage will void the dyno warranty. Contact Dynojet with any questions.
The model 200i/250i dynamometer requires a dedicated wall receptacle which must be wired for operation and is included with the dyno or may be shipped in advance in a separate package. The dyno is equipped with a ten foot power cord with a twist lock plug pre-wired on the end. The power cord is located at the front of the dyno, but is shipped inside of the dyno. For more information on the location and routing instructions for the power cord refer to your dyno installation guide.
The dedicated wall receptacle is a twist lock four wire grounded 30A NEMA L14-30 type and must be wired in accordance with local building codes and requirements. If the facility does not have 120/240 volt single phase power, and it does have 120/208 volt three phase Y power, then it is acceptable to connect the four-wire receptacle with two of the three phase lines, the neutral and the ground. With this arrangement, there will only be 208 volts between line 1 and line 2 instead of 240 volts. This is acceptable, but performance of the retarder will be reduced. In no case shall all three phase lines be connected to the receptacle!
Installation may require a licensed electrician and must conform to UL and NEC safety standards.
Note: If you are installing your dyno in North America or Japan and the dyno is not equipped with twist lock four wire grounded plug, contact Dynojet before attempting to connect the dyno.
Local and national electrical codes require a grounded receptacle box.
• This circuit should have a dedicated 30A double pole circuit breaker.
• The dyno should be the only device connected to this circuit.
• It may be necessary to install a delayed trip breaker due to the inrush current drawn by the high pressure blowers.
B-2
Pre-Installation Guide for Model 200i/250i, 200iP/250iP, 250iX, and 250iPX Motorcycle Dynamometers
P O W E R R E Q U I R E M E N T S A N D I N S T A L L A T I O N
Locations Using 60 Hz Power (North America and Japan)
I NSTALLING THE W ALL R ECEPTACLE
The wall receptacle is included with your dyno and is shipped in a box in the center of your dyno or may be shipped in advance in a separate package.
The wall receptacle is a single phase 240 volt 30A dedicated circuit with a neutral connection and a ground. The neutral connection is required to split the 240 volt into two 120 volt connections internal to the dyno.
The cable carrying the power to this receptacle should be ten gauge or larger. Check with local building codes for the correct size.
1 Connect one of the 240V legs (line 1) to the X terminal (gold colored screw).
2 Connect the other 240V leg (line 2) to the Y terminal (gold colored screw).
3 Connect the neutral conductor to the W or WH terminal (silver screw).
4 Connect the ground conductor to the green grounding screw.
Version 3 Pre-Installation Guide for Model 200i/250i, 200iP/250iP, 250iX, and 250iPX Motorcycle Dynamometers
B-3
A P P E N D I X B
Locations Using 60 Hz Power (North America and Japan)
T ESTING FOR C ORRECT V OLTAGES
You must test the receptacle for proper voltages before the dyno is connected to the outlet.
If the voltage readings do not match the following table, DO NOT connect the dyno. You must have a licensed electrician correct the power connection.
Connecting the dyno to the incorrect voltage can result in damage to the dyno and will void the dyno warranty. Contact Dynojet with any questions.
Using a voltmeter that is capable of measuring AC voltage, measure between the points listed below and verify that the correct voltages are present.
1
3
1
1 probe 1
2 probe 2
4
4
2
3 box desired voltage measurement
216V to 260V*
108V to 130V
108V to 130V
<5V
<5V
*If using two of the three phase lines of a 120/208V 3 phase Y system, then expect to see 187V to 225V.
3
4
2
1
Figure B-1: Dedicated Power Receptacle
B-4
Pre-Installation Guide for Model 200i/250i, 200iP/250iP, 250iX, and 250iPX Motorcycle Dynamometers
P O W E R R E Q U I R E M E N T S A N D I N S T A L L A T I O N
Locations Using 60 Hz Power (North America and Japan)
R EPLACING THE P OWER P LUG
Use the following instructions to replace the four wire plug and socket.
The plug and socket configuration must be rated for at least 240VAC 30A and have a minimum of four conductors.
The power cord that attaches to the dyno has four conductors internally and their colors are brown, blue, black, and green/yellow.
1 Connect 240VAC single phase power between the brown and the blue wire connection points.
2 Connect the green/yellow wire to the ground connection point.
3 Wrap the black wire with the white tape to denote that it is a neutral connection and connect it to the neutral connection point.
4 Refer to the previous table for testing and probe the new connections as follows:
• blue wire as location #2
• brown wire as location #4
• black wire as location #1
• green/yellow wire as location #3
H ARD W IRING TO THE B UILDING
Use the following instructions to wire the dyno directly to the building.
The dyno must connect to a two pole disconnect switch to allow the removal of all power to the dyno for servicing. This box may contain fusing, circuit breakers, or the circuit protection may be upstream in the building power system. The circuit must be protected to 30A with slow blow fuses or time delayed circuit breakers.
The power cord that attaches to the dyno has four conductors internally and their colors are brown, blue, black, and green/yellow.
1 Remove the dyno power plug and connect 240VAC single phase between the brown and the blue wires through the disconnect switch.
2 Connect the green/yellow wire to the ground connection.
3 Wrap the black wire with white tape to denote that it is a neutral connection and connect it to the neutral connection.
4 Refer to the previous table for testing and probe the new connections as follows:
• blue wire as location #2
• brown wire as location #4
• black wire as location #1
• green/yellow wire as location #3
Version 3 Pre-Installation Guide for Model 200i/250i, 200iP/250iP, 250iX, and 250iPX Motorcycle Dynamometers
B-5
A P P E N D I X B
Locations Using 60 Hz Power (North America and Japan)
C ONNECTING THE D YNO
1 Turn off the main circuit breaker on the dyno. The main breaker is located in the
CPI door. Off is the down position.
2 Once you verify the voltages on the receptacle, connect the dyno to the receptacle.
3 Connect the high pressure blowers to the dyno. For more information on connecting the blowers, refer to your dyno installation guide.
4 Turn on the main dyno breaker.
5 Test the blowers for operation.
6 Turn on the dyno electronics and verify operation.
7 Test the control panel operations. For more information, refer to your dyno installation guide.
B-6
Pre-Installation Guide for Model 200i/250i, 200iP/250iP, 250iX, and 250iPX Motorcycle Dynamometers
P O W E R R E Q U I R E M E N T S A N D I N S T A L L A T I O N
Locations Using 50 Hz Power (Locations other than North America and Japan)
LOCATIONS USING 50 HZ POWER (LOCATIONS OTHER THAN NORTH AMERICA
The next section of this appendix contains the power requirements and instructions for dyno installations excluding North America and 60 Hz areas of Japan.
Note:
Refer to page B-2 for power requirements and instructions for North
America and Japan.
The model 200i/250i dynamometer (excluding North America and Japan) requires a dedicated wall receptacle which must be wired for operation and is included with the dyno or may be shipped in advanced in a separate package. The dyno is equipped with a ten foot power cord with a three-pin IEC plug pre-wired on the end. The power cord is located at the front of the dyno, but is shipped inside of the dyno. For more information on the location and routing instructions for the power cord refer to your dyno installation guide.
The model 200i/250i dynamometer requires a dedicated 240VAC single phase power outlet rated for 30A for proper operation. Failure to follow these instructions could result in personal injury or damage to the dyno.
Connecting the dyno to the incorrect voltage will void the dyno warranty. Contact Dynojet with any questions.
The dedicated wall receptacle is a three-pin IEC grounded 30A type and must be wired in accordance with local building codes and requirements. Installation may require a licensed electrician to conform to applicable safety standards.
If you are installing your dyno in a location other than North America or Japan and the dyno is not equipped with a three pin IEC grounded plug, contact
Dynojet before attempting to connect the dyno.
Local and national electrical codes will require that the box containing the receptacle is grounded.
• This circuit should have a dedicated 30A double pole circuit breaker.
• The dyno should be the only device connected to this circuit.
• It may be necessary to install a delayed trip breaker due to the inrush current drawn by the high pressure blowers.
Version 3 Pre-Installation Guide for Model 200i/250i, 200iP/250iP, 250iX, and 250iPX Motorcycle Dynamometers
B-7
A P P E N D I X B
Locations Using 50 Hz Power (Locations other than North America and Japan)
I NSTALLING THE W ALL R ECEPTACLE
The wall receptacle is a single 240 volt 30A dedicated circuit with a ground.
The cable carrying the power to this receptacle should be 4.0 mm
2
(ten gauge) or larger. Check with local building codes for the correct size.
1 Connect one of the 240V legs to the N terminal (white).
2 Connect the other 240V leg to the L terminal (no color).
3 Connect the ground conductor to the green terminal.
L terminal
N terminal
(white)
Figure B-2: Wire the Wall Receptacle ground terminal
(green)
B-8
Pre-Installation Guide for Model 200i/250i, 200iP/250iP, 250iX, and 250iPX Motorcycle Dynamometers
P O W E R R E Q U I R E M E N T S A N D I N S T A L L A T I O N
Locations Using 50 Hz Power (Locations other than North America and Japan)
T ESTING FOR C ORRECT V OLTAGES
You must test the receptacle for proper voltages before the dyno is connected to the outlet.
Using a voltmeter that is capable of measuring AC voltage, measure between the points listed below and verify that the correct voltages are present.
probe 1
1
2 probe 2
3 box desired voltage measurement
220V to 250V
<5V
1
2
Figure B-3: Test the Wall Receptacle
3
Version 3 Pre-Installation Guide for Model 200i/250i, 200iP/250iP, 250iX, and 250iPX Motorcycle Dynamometers
B-9
A P P E N D I X B
Locations Using 50 Hz Power (Locations other than North America and Japan)
R EPLACING THE P OWER P LUG
Use the following instructions to replace the plug and socket.
The plug and socket configuration must be rated for at least 240VAC 30A and have a minimum of three conductors.
The power cord that attaches to the dyno has four conductors internally and their colors are brown, blue, black, and green/yellow.
1 Connect 240VAC single phase power between the brown and the blue wire connection points.
2 Connect the green/yellow wire to the ground connection point.
3 Cut off the black wire.
4 Refer to the previous table for testing and probe the new connections as follows:
• blue wire as location #1
• brown wire as location #3
• green/yellow wire as location #2
H ARD W IRING TO THE B UILDING
Use the following instructions to wire the dyno directly to the building.
The dyno must connect to a two-pole disconnect switch to allow the removal of all power to the dyno for servicing. This box may contain fusing, circuit breakers, or the circuit protection may be upstream in the building power system. The circuit must be protected to 30A with slow blow fuses or time-delayed circuit breakers.
The power cord that attaches to the dyno has four conductors internally and their colors are brown, blue, black, and green/yellow.
1 Remove the dyno power plug and connect 240VAC single phase between the brown and the blue wires through the disconnect switch.
2 Connect the green/yellow wire to the ground connection.
3 Cut off the black wire.
4 Refer to the previous table for testing and probe the new connections as follows:
• blue wire as location #1
• brown wire as location #3
• green/yellow wire as location #2
B-10
Pre-Installation Guide for Model 200i/250i, 200iP/250iP, 250iX, and 250iPX Motorcycle Dynamometers
P O W E R R E Q U I R E M E N T S A N D I N S T A L L A T I O N
Locations Using 50 Hz Power (Locations other than North America and Japan)
C ONNECTING THE D YNO
1 Turn off the main circuit breaker on the dyno. The main breaker is located in the
CPI door. Off is the down position.
2 Once you verify the voltages on the receptacle, connect the dyno to the receptacle.
3 Connect the high pressure blowers to the dyno. For more information on connecting the blowers, refer to your dyno installation guide.
4 Turn on the main dyno breaker.
5 Test the blowers for operation.
6 Turn on the dyno electronics and verify operation.
7 Test the control panel operations. For more information, refer to your dyno installation guide.
Version 3 Pre-Installation Guide for Model 200i/250i, 200iP/250iP, 250iX, and 250iPX Motorcycle Dynamometers
B-11
I
NDEX
200i dyno
1-7 chassis specifications
1-7 dimensions 1-8 ground hook placement
1-12 room layout
1-10
200iP dyno 1-13 chassis specifications
1-13 dimensions
1-14 pit specifications 1-13 room layout
1-15
250i dyno
1-7 chassis specifications 1-7 dimensions 1-9 ground hook placement
1-12 room layout 1-10
250iP dyno 1-13 chassis specifications
1-13 dimensions 1-14 pit specifications 1-13 room layout
1-15
250iPX dyno 1-21 chassis specifications 1-21 dimensions
1-22 pit specifications 1-21 room layout 1-23
250iX dyno
1-17 chassis specifications 1-17 dimensions 1-18 room layout
1-19
50 Hz power B-7
60 Hz power B-2
B battery hazards iv battery requirements 1-4
C chassis specifications
200i dyno
1-7
200iP dyno 1-13
250i dyno
1-7
250iP dyno
1-13
250iPX dyno 1-21
250iX dyno
1-17 height
1-21 length 1-21 weight
1-21 width
1-21 compressed air requirements 1-4 computer specifications 1-4 connecting power to the dyno
50 Hz B-11
60 Hz B-6 control panel interface, dimensions
1-14 , 1-22 conventions 1-2 crate 1-25
D dimensions
200i dyno 1-8
200iP dyno 1-14
250i dyno
1-9
250iP dyno 1-14
250iPX dyno 1-22
250iX dyno
1-18 control panel interface 1-14 , 1-22 disclaimers iii document part number
1-1 drill and drill bit 1-5 dyno height
1-21 length 1-21 weight 1-21 width
1-21
Pre-Installation Guide for Model 200i/250i, 200iP/250iP, 250iX, and 250iPX Motorcycle Dynamometers
Index-i
I N D E X dyno room cooling fan
1-3 exhaust extraction
1-3 fire suppression
1-3
Industrial Noise Control
1-3
E electrical requirements
1-5 electrostatic discharge iv environmental requirements
1-6
ESD precautions iv
F fire suppression
1-6 forklift requirements
1-6
G ground hook placement
200i dyno
1-12
250i dyno
1-12
H hard wiring power
50 Hz
B-10
60 Hz
B-5 hazards v height
1-7 , 1-13 , 1-17 , 1-21
I
Industrial Noise Control
1-3 installation guide, locating
1-25 installing power receptacle
50 Hz
B-8
60 Hz
B-3
L length
1-7 , 1-13 , 1-17 , 1-21
P pit specifications
200iP dyno
1-13
250iP dyno
1-13
250iPX dyno
1-21 power
50 Hz
B-7
60 Hz
B-2 connecting the dyno, 50 Hz
B-11 connecting the dyno, 60 Hz
B-6 hard wiring 60 Hz
B-5 hard wiring, 50 Hz
B-10 installation 50 Hz
B-7 installation 60 Hz
B-2 installing receptacle 60 Hz
B-3 installing receptacle, 50 Hz
B-8 replacing power plug 50 Hz
B-10
Index-ii
Pre-Installation Guide for Model 200i/250i, 200iP/250iP, 250iX, and 250iPX Motorcycle Dynamometers replacing power plug 60 Hz
B-5 requirements 50 Hz
B-7 requirements 60 Hz
B-2 testing voltages 50 Hz
B-9 testing voltages 60 Hz
B-4 verifying operation, 50 Hz
B-11 verifying operation, 60 Hz
B-6
R red head anchor contact information
A-1 installation
A-2 setting tool
A-3 warnings
A-1 replacing power plug
50 Hz
B-10
60 Hz
B-5 requirements battery
1-4 compressed air
1-4 computer specifications
1-4 drill and drill bit
1-5 electrical
1-5 environmental
1-6 fire suppression
1-6 forklift
1-6 phone and internet
1-6 power 50 Hz
B-7 power 60 Hz
B-2 tie-down straps
1-6 room layout
200i dyno
1-10
200iP dyno
1-15
250i dyno
1-10
250iP dyno
1-15
250iPX dyno
1-23
250iX dyno
1-19
S setting tool
A-3
T technical support
1-2 testing voltages
50 Hz
B-9
60 Hz
B-4
U unpacking
1-25
W warnings iii weight
1-7 , 1-13 , 1-17 , 1-21 width
1-7 , 1-13 , 1-17 , 1-21
Download