Overview of the Cisco UCS C-Series Rack-Mount Servers 1
Overview of the Server Software 1
Cisco Integrated Management Controller 3
Overview of the Cisco IMC User Interface 4
Cisco Integrated Management Controller Online Help Overview 9
Installing an OS Using the KVM Console 12
Installing an OS Using a PXE Installation Server 13
Booting an Operating System from a USB Port 14
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
iii
Contents
C H A P T E R 3
C H A P T E R 4
Viewing Power Supply Properties 19
Viewing Cisco VIC Adapter Properties 19
Viewing SAS Expander Properties 20
Enabling 6G or 12G Mixed Mode on a SAS Expander 20
Viewing Network Adapter Properties 22
Configuring the Precision Boot Order 27
Overview to UEFI Secure Boot 36
Viewing the Actual Server Boot Order 39
Configuring a Server to Boot With a One-Time Boot Device 40
Creating a Server Asset Tag 40
Setting Power Redundancy Policy 41
Enabling Power Characterization 42
Configuring Standard Power Profiles Settings 44
Configuring Advanced Power Profile Settings 45
Resetting Power Profiles to Default 46
iv
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Contents
C H A P T E R 5
Viewing Power Monitoring Summary 47
Viewing the Power Statistics in a Chart 50
Downloading Power Statistics and Server Utilization Data 51
Configuring the Power Restore Policy 52
Configuring DIMM Blacklisting 56
Enabling DIMM Black Listing 57
Restoring BIOS Manufacturing Custom Settings 59
Viewing BIOS Profile Details 62
Setting Dynamic Front Panel Temperature Threshold 63
Viewing PCI Adapter Properties 70
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
v
Contents
C H A P T E R 6
C H A P T E R 7
C H A P T E R 8
Viewing Power Supply Sensors 75
Viewing Temperature Sensors 77
Configuring Serial Over LAN 83
Creating a Cisco IMC Mapped vMedia Volume 85
Viewing Cisco IMC-Mapped vMedia Volume Properties 90
Removing a Cisco IMC-Mapped vMedia Volume 91
Remapping an Existing Cisco IMC vMedia Image 91
Deleting a Cisco IMC vMedia Image 91
Configuring the Virtual KVM 97
Managing SSH Keys in User Accounts 101
vi
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Contents
C H A P T E R 9
C H A P T E R 1 0
Switching between IPMI and Non-IPMI User Modes 106
Changing Password as a Non-Admin User 106
Configuring Password Expiry Duration 109
Configuring Account Lockout Details 111
Configuring User Authentication Precedence 111
Resetting User Credentials to Factory Default Values 112
Configuring the LDAP Server 113
Configuring LDAP Settings and Group Authorization in Cisco IMC 114
LDAP Certificates Overview 119
Viewing LDAP CA Certificate Status 119
Exporting an LDAP CA Certificate 119
Downloading an LDAP CA Certificate 122
TACACS+ Server Configuration 124
Enabling TACACS+ Authentication 125
Configuring TACACS+ Remote Server Settings 125
Configuring Chassis Related Settings 129
Pinging a Hostname/IP Address from the Web UI 130
Configuring Network-Related Settings 133
Common Properties Configuration 140
Overview to Common Properties Configuration 140
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
vii
Contents
C H A P T E R 1 1
Configuring Common Properties 140
Connecting to a Port Profile 143
Configuring Individual Settings 145
Network Security Configuration 146
Configuring Network Security 146
Network Time Protocol Settings 147
Network Time Protocol Service Setting 147
Configuring Network Time Protocol Settings 147
Overview of the Cisco UCS C-Series Network Adapters 149
Configuring Network Adapter Properties 151
Guidelines for Managing vHBAs 158
Deleting a vHBA 170 vHBA Boot Table 170
Creating a Boot Table Entry 170
Deleting a Boot Table Entry 171 vHBA Persistent Binding 171
Viewing Persistent Bindings 172
Rebuilding Persistent Bindings 172
Guidelines for Managing vNICs 173
viii
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Contents
C H A P T E R 1 2
Configuring iSCSI Boot Capability 190
Configuring iSCSI Boot Capability for vNICs 190
Configuring iSCSI Boot Capability on a vNIC 190
Removing iSCSI Boot Configuration from a vNIC 193
Viewing and Configuring Cisco usNIC using the Cisco IMC GUI 194
Backing Up and Restoring the Adapter Configuration 199
Exporting the Adapter Configuration 199
Importing the Adapter Configuration 200
Restoring Adapter Defaults 201
Self Encrypting Drives (Full Disk Encryption) 203
Enabling Controller Security 204
Modifying Controller Security 205
Disabling Controller Security 206
Switching Controller Security Between Local and Remote Key Management 207
Creating Virtual Drive from Unused Physical Drives 207
Creating Virtual Drive from an Existing Drive Group 209
Setting a Virtual Drive to Transport Ready State 211
Setting a Virtual Drive as Transport Ready 211
Clearing a Virtual Drive from Transport Ready State 212
Importing Foreign Configuration 213
Clearing Foreign Configuration 213
Retrieving Storage Firmware Logs for a Controller 215
Clearing Controller Configuration 216
Restoring Storage Controller to Factory Defaults 216
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
ix
Contents
Preparing a Drive for Removal 216
Undo Preparing a Drive for Removal 217
Making a Dedicated Hot Spare 217
Removing a Drive from Hot Spare Pools 218
Toggling Physical Drive Status 219
Setting a Physical Drive as a Controller Boot Drive 219
Initializing a Virtual Drive 220
Starting Learn Cycles for a Battery Backup Unit 223
Viewing Storage Controller Logs 224
Viewing SSD Smart Information for MegaRAID Controllers 225
Viewing NVMe Controller Details 225
Viewing NVMe Physical Drive Details 227
Viewing PCI Switch Details 229
Starting Copyback Operation 230
Managing the Flexible Flash Controller 231
Upgrading from Single Card to Dual Card Mirroring with FlexFlash 232
Configuring the Flexible Flash Controller Properties 233
Configuring the Flexible Flash Controller Cards 234
Resetting the Flexible Flash Controller 235
Viewing FlexFlash Log Details 238
Managing the FlexUtil Controller 240
Configuring FlexUtil Controller Properties 240
Resetting FlexUtil Card Configuration 241
Viewing Cisco FlexUtil Controller Properties 242
Viewing Physical Drive Properties 243
x
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Contents
C H A P T E R 1 3
C H A P T E R 1 4
Viewing Virtual Drive Properties 245
Mapping an Image to a Virtual Drive 247
Updating an Image on the Virtual Drive 249
Unmapping an Image From a Virtual Drive 250
Cisco Boot Optimized M.2 Raid Controller 251
Viewing Cisco Boot Optimized M.2 Raid Controller Details 251
Viewing Physical Drive Info for Cisco Boot Optimized M.2 Raid Controller 254
Viewing the Virtual Drive Info for Cisco Boot Optimized M.2 Raid Controller 258
Configuring Communication Services 261
Configuring SNMP Properties 266
Configuring SNMP Trap Settings 268
Sending a Test SNMP Trap Message 269
Configuring a Server to Send Email Alerts Using SMTP 272
Configuring SMTP Server For Receiving Email Alerts 272
Adding SMTP Email Recipients 274
Managing Certificates and Server Security 277
Managing the Server Certificate 277
Generating a Certificate Signing Request 278
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
xi
Contents
C H A P T E R 1 5
C H A P T E R 1 6
Creating a Self-Signed Certificate 280
Creating a Self-Signed Certificate Using Windows 282
Uploading a Server Certificate 283
Managing the External Certificate 284
Uploading an External Certificate 284
Uploading an External Private Key 286
Activating the External Certificate 288
Key Management Interoperability Protocol 288
Viewing Secure Key Management Settings 289
Creating a Client Private Key and Client Certificate for KMIP Configuration 291
Downloading a Client Certificate 292
Exporting a Client Certificate 294
Deleting a Client Certificate 296
Downloading a Root CA Certificate 296
Exporting a Root CA Certificate 298
Deleting a Root CA Certificate 300
Downloading a Client Private Key 300
Exporting a Client Private Key 302
Deleting a Client Private Key 304
Testing the KMIP Server Connection 304
Restoring the KMIP Server to Default Settings 304
Deleting KMIP Login Details 305
FIPS 140-2 Compliance in Cisco IMC 305
Enabling Security Configuration 305
Firmware Management Overview 307
Viewing Firmware Components 308
Cancelling Firmware Activation 310
xii
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Contents
C H A P T E R 1 7
Sending the Cisco IMC Log to a Remote Server 323
Configuring the Cisco IMC Log Threshold 324
Sending a Test Cisco IMC Log to a Remote Server 325
Exporting Technical Support Data 327
Exporting Technical Support Data 327
Downloading Technical Support Data to a Local File 329
Resetting to Factory Default 330
Exporting and Importing the Cisco IMC Configuration 331
Exporting and Importing the Cisco IMC Configuration 331
Exporting the Cisco IMC Configuration 332
Importing the Cisco IMC Configuration 334
Generating Non Maskable Interrupts to the Host 337
Adding or Updating the Cisco IMC Banner 337
Viewing Cisco IMC Last Reset Reason 338
Downloading Hardware Inventory to a Local File 339
Exporting Hardware Inventory Data to a Remote Server 339
Enabling or Disabling Cisco Intersight Management 344
Viewing Intersight Device Connector Properties 344
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
xiii
Contents
C H A P T E R 1 8
A P P E N D I X A
Recording the Last Boot Process 349
Playing a Recorded Video Using the DVR Player on the KVM Console 352
BIOS Parameters by Server Model 353
C220 M5, C240 M5, C240 SD M5, and C480 M5 Servers 368
Main Tab for C460 M4 Servers 395
Advanced Tab for C460 M4 Servers 396
Server Management Tab for C460 M4 Servers 416
C220 M4 and C240 M4 Servers 418
Main Tab for C220M4 and C240M4 Servers 418
Advanced Tab for C220M4 and C240M4 Servers 419
Server Management Tab for C220M4 and C240M4 Servers 440
xiv
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Preface
This preface includes the following sections:
•
•
•
Related Cisco UCS Documentation, on page xvii
Audience
This guide is intended primarily for data center administrators with responsibilities and expertise in one or more of the following:
• Server administration
• Storage administration
• Network administration
• Network security
Conventions
Text Type
GUI elements
Document titles
TUI elements
System output
CLI commands
Indication
GUI elements such as tab titles, area names, and field labels appear in this font .
Main titles such as window, dialog box, and wizard titles appear in this font .
Document titles appear in this font .
In a Text-based User Interface, text the system displays appears in this font .
Terminal sessions and information that the system displays appear in this font .
CLI command keywords appear in this font .
Variables in a CLI command appear in this font .
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
xv
Preface
Preface
Text Type
[ ]
{x | y | z}
[x | y | z] string
< >
[ ]
!, #
Indication
Elements in square brackets are optional.
Required alternative keywords are grouped in braces and separated by vertical bars.
Optional alternative keywords are grouped in brackets and separated by vertical bars.
A nonquoted set of characters. Do not use quotation marks around the string or the string will include the quotation marks.
Nonprinting characters such as passwords are in angle brackets.
Default responses to system prompts are in square brackets.
An exclamation point (!) or a pound sign (#) at the beginning of a line of code indicates a comment line.
Note Means reader take note . Notes contain helpful suggestions or references to material not covered in the document.
Tip Means the following information will help you solve a problem . The tips information might not be troubleshooting or even an action, but could be useful information, similar to a Timesaver.
Timesaver Means the described action saves time . You can save time by performing the action described in the paragraph.
Caution Means reader be careful . In this situation, you might perform an action that could result in equipment damage or loss of data.
Warning IMPORTANT SAFETY INSTRUCTIONS
This warning symbol means danger. You are in a situation that could cause bodily injury. Before you work on any equipment, be aware of the hazards involved with electrical circuitry and be familiar with standard practices for preventing accidents. Use the statement number provided at the end of each warning to locate its translation in the translated safety warnings that accompanied this device.
SAVE THESE INSTRUCTIONS xvi
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Preface
Related Cisco UCS Documentation
Related Cisco UCS Documentation
Documentation Roadmaps
For a complete list of all B-Series documentation, see the Cisco UCS B-Series Servers Documentation Roadmap available at the following URL: https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/overview/ guide/UCS_roadmap.html
For a complete list of all C-Series documentation, see the Cisco UCS C-Series Servers Documentation Roadmap available at the following URL: https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/overview/ guide/ucs_rack_roadmap.html
.
For information on supported firmware versions and supported UCS Manager versions for the rack servers that are integrated with the UCS Manager for management, refer to Release Bundle Contents for Cisco UCS
Software .
Other Documentation Resources
Follow Cisco UCS Docs on Twitter to receive document update notifications.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
xvii
Related Cisco UCS Documentation
Preface xviii
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
C H A P T E R
1
Overview
This chapter includes the following sections:
•
Overview of the Cisco UCS C-Series Rack-Mount Servers, on page 1
•
Overview of the Server Software, on page 1
•
•
Cisco Integrated Management Controller, on page 3
•
Overview of the Cisco IMC User Interface, on page 4
Overview of the Cisco UCS C-Series Rack-Mount Servers
The Cisco UCS C-Series rack-mount servers include the following models:
• Cisco UCS C240 SD M5 Rack-Mount Server
• Cisco UCS C125 Rack-Mount Server
• Cisco UCS C220 M5 Rack-Mount Server
• Cisco UCS C240 M5 Rack-Mount Server
• Cisco UCS C480 M5 Rack-Mount Server
• Cisco UCS C220 M4 Rack-Mount Server
• Cisco UCS C240 M4 Rack-Mount Server
• Cisco UCS C460 M4 Rack-Mount Server
Note To determine which Cisco UCS C-Series rack-mount servers are supported by this firmware release, see the associated Release Notes . The C-Series release notes are available at the following URL: http://www.cisco.com/en/US/products/ps10739/prod_release_notes_list.html
Overview of the Server Software
The Cisco UCS C-Series Rack-Mount Server ships with the Cisco IMC firmware.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
1
Overview
Server Ports
Cisco IMC Firmware
Cisco IMC is a separate management module built into the motherboard. A dedicated ARM-based processor, separate from the main server CPU, runs the Cisco IMC firmware. The system ships with a running version of the Cisco IMC firmware. You can update the Cisco IMC firmware, but no initial installation is needed.
Server OS
The Cisco UCS C-Series rack server supports operating systems such as Windows, Linux, Oracle and so on.
For more information on supported operating systems, see the Hardware and Software Interoperability for
Standalone C-series servers at http://www.cisco.com/en/US/products/ps10477/prod_technical_reference_ list.html
. You can use Cisco IMC to install an OS on the server using the KVM console and vMedia.
Note You can access the available OS installation documentation from the Cisco UCS C-Series Servers
Documentation Roadmap at http://www.cisco.com/go/unifiedcomputing/c-series-doc .
Server Ports
Following is a list of server ports and their default port numbers:
Table 1: Server Ports
Port Name
LDAP Port 1
LDAP Port 2
LDAP Port 3
LDAP Port 4
LDAP Port 5
LDAP Port 6
SSH Port
HTTP Port
HTTPS Port
SMTP Port
KVM Port
Andromeda Management Port
Andromeda Cloud Port
SOL SSH Port
443
25
2068
8889
3268
3268
22
80
8888
2400
Port Number
389
389
389
3268
2
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Overview
Cisco Integrated Management Controller
Port Name
SNMP Port
SNMP Traps
External Syslog
Port Number
161
162
514
Cisco Integrated Management Controller
The Cisco IMC is the management service for the C-Series servers. Cisco IMC runs within the server.
Note The Cisco IMC management service is used only when the server is operating in Standalone Mode. If your
C-Series server is integrated into a UCS system, you must manage it using UCS Manager. For information about using UCS Manager, see the configuration guides listed in the Cisco UCS B-Series Servers Documentation
Roadmap at http://www.cisco.com/go/unifiedcomputing/b-series-doc .
Management Interfaces
You can use a web-based GUI or SSH-based CLI or an XML-based API to access, configure, administer, and monitor the server. Almost all tasks can be performed in either interface, and the results of tasks performed in one interface are displayed in another. However, you cannot do the following:
• Use Cisco IMC GUI to invoke Cisco IMC CLI
• View a command that has been invoked through Cisco IMC CLI in Cisco IMC GUI
• Generate Cisco IMC CLI output from Cisco IMC GUI
Tasks You Can Perform in Cisco IMC
You can use Cisco IMC to perform the following chassis management tasks:
• Power on, power off, power cycle, reset and shut down the server
• Toggle the locator LED
• Configure the server boot order
• View server properties and sensors
• Manage remote presence
• Create and manage local user accounts, and enable remote user authentication through Active Directory
• Configure network-related settings, including NIC properties, IPv4, VLANs, and network security
• Configure communication services, including HTTP, SSH, IPMI Over LAN, and SNMP
• Manage certificates
• Configure platform event filters
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
3
Overview
Overview of the Cisco IMC User Interface
• Update Cisco IMC firmware
• Monitor faults, alarms, and server status
• Set time zone and view local time
• Install and activate Cisco IMC firmware
• Install and activate BIOS firmware
• Install and activate CMC firmware
You can use Cisco IMC to perform the following server management tasks:
• Manage remote presence
• Create and manage local user accounts, and enable remote user authentication through Active Directory
• Configure network-related settings, including NIC properties, IPv4, VLANs, and network security
• Configure communication services, including HTTP, SSH, IPMI Over LAN, and SNMP
• Manage certificates
• Configure platform event filters
• Update Cisco IMC firmware
• Monitor faults, alarms, and server status
• Set time zone and view local time
No Operating System or Application Provisioning or Management
Cisco IMC provisions servers, and as a result, exists below the operating system on a server. Therefore, you cannot use it to provision or manage operating systems or applications on servers. For example, you cannot do the following:
• Deploy an OS, such as Windows or Linux
• Deploy patches for software, such as an OS or an application
• Install base software components, such as anti-virus software, monitoring agents, or backup clients
• Install software applications, such as databases, application server software, or web servers
• Perform operator actions, including restarting an Oracle database, restarting printer queues, or handling non-Cisco IMC user accounts
• Configure or manage external storage on the SAN or NAS storage
Overview of the Cisco IMC User Interface
The Cisco IMC user interface is a web-based management interface for Cisco C-Series servers. The web user interface is developed using HTML5 with the eXtensible Widget Framework (XWT) framework. You can launch the user interface and manage the server from any remote host that meets the following minimum requirements:
4
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Overview
Cisco IMC Home Page
• Microsoft Internet Explorer 6.0 or higher, Mozilla Firefox 3.0 or higher
• Microsoft Windows 7, Microsoft Windows XP, Microsoft Windows Vista, Apple Mac OS X v10.6, Red
Hat Enterprise Linux 5.0 or higher operating systems
• Transport Layer Security (TLS) version 1.3
Note In case you lose or forget the password that you use to log in to Cisco IMC, see the password recovery instructions in the Cisco UCS C-Series server installation and service guide for your server. This guide is available from the Cisco UCS C-Series Servers Documentation Roadmap at http://www.cisco.com/go/ unifiedcomputing/c-series-doc .
Cisco IMC Home Page
When you first log into Cisco IMC GUI, the user interface looks similar to the following illustration:
Note There may be user interface changes, which do not have functionality impact, from release to release.
Navigation and Work Panes
The Cisco Integrated Management Controller GUI comprises the Navigation pane on the left hand side of the screen and the Work pane on the right hand side of the screen. Clicking links on the Chassis , Compute ,
Networking , Storage or Admin menu in the Navigation pane displays the associated tabs in the pane on the right.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
5
Overview
Navigation and Work Panes
The Navigation pane header displays action buttons that allow you to view the navigation map of the entire
GUI, view the index, or select a favorite work pane to go to, directly. The Pin icon prevents the Navigation pane from sliding in once the Work pane displays.
The Favorite icon is a star shaped button which allows you to make any specific work pane in the application as your favorite. To do this, navigate to the work pane of your choice and click the Favorite icon. To access this work pane directly from anywhere else in the application, click the Favorite icon again.
The GUI header displays information about the overall status of the chassis and user login information.
On the right of the GUI header is a gear icon. Click on the gear icon and the drop-down lists the Change
Password and Logout options. You can use the change password option to change your password.
Note When you change your password you will be logged out of Cisco IMC.
Note Change Password option is not available when you login as an admin, you can only change the password of the configured users with read-only user privileges.
When you change your password you will be logged out of Cisco IMC.
The Logout option allows you to log out of Cisco IMC.
The GUI header also displays the total number of faults (indicated in green or red), with a Bell icon next to it. However, clicking this icon displays the summary of only the critical and major faults of various components.
To view all the faults, click the View All button to display the Fault Summary pane.
Note User interface options may vary depending on the server.
The Navigation pane has the following menus:
• Chassis Menu
• Compute Menu
• Networking Menu
• Storage Menu
• Admin Menu
Chassis Menu
Each node in the Chassis menu leads to one or more tabs (except for Summary pane) that display in the
Work pane. These tabs provides access to the following information:
6
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Overview
Navigation and Work Panes
Chassis Menu Node Name
Summary
Inventory
Sensors
Power Management
Faults and Logs
Work Pane Provide Information About...
Server properties, Chassis status, Cisco Integrated Management
Controller (Cisco IMC) information, and Server Utilization.
Note Server Utilization is available on some Cisco UCS
C-Series servers.
CPU, memory, PCI adapters, power supplies, cisco VIC adapters, network adapters, storage, SAS expander, and TPM.
Power Supply, Fan, Temperature, Voltage, Current, LEDs, and
Storage.
Power Cap Configuration and Power Monitoring.
Note This option is not available for Cisco UCS C125 servers.
Fault summary, Fault history, System Event Log, Cisco IMC Log, and logging controls.
Compute Menu
The Compute menu contains information about the server, and the following information is displayed in the
Work pane.
Compute Menu Node Name
BIOS
Work Pane Tabs Provide Information About...
The installed BIOS firmware version and BIOS profile configuration, server boot order configuration, I/O, Server management, Security, Processor, Memory, Power or Performance.
Remote Management
Troubleshooting
Virtual KVM, Virtual Media, and Serial over LAN.
Bootstrap Process Recording Actions include Play Recording and
Download Recording, and Crash Recording Actions include Play
Recording, Capture Recording, and Download Recording.
Power restore policy settings.
Power Policies
PID Catalog
Secure Key Management
CPU, memory, PCI adapters, and the HDD details.
Details of KMIP Servers, KMIP Root CA and Client Certificate details, KMIP login details, KMIP Client Private key status
Networking Menu
Each node in the Networking menu leads to one or more tabs that display in the Work pane. These tabs provides access to the following information:
Networking Menu Node Name
General
Work Pane Tabs Provide Information About...
Adapter card properties, firmware, external ethernet interfaces, and actions to export or import configurations, and reset status.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
7
Overview
Navigation and Work Panes
Networking Menu Node Name
External Ethernet Interfaces vNICs vHBAs
Work Pane Tabs Provide Information About...
External ethernet interfaces information such as port, admin speed,
MAC address, link state.
Host ethernet interfaces information such as name, CDN, MAC address, MTU and individual vNIC properties.
Host fibre channel interfaces information such as name, WWPN,
WWNN, boot, uplink, port profile, channel number, and individual vHBA properties.
Storage Menu
Each node in the Storage menu corresponds to the LSI MegaRAID controllers or Host Bus Adapters (HBA) that are installed in theCisco UCS C-Series Rack-Mount Servers. Each node leads to one or more tabs that display in the Work pane and provide information about the installed controllers.
Storage Menu Node Name
Controller Info
Work Pane Tabs Provide Information About...
General information about the selected LSI MegaRAID controller or HBA.
Physical Drive Info General drive information, RAID information, and physical drive information.
Virtual Drive Info
Battery Backup Unit
Storage Log
General information about virtual drives, RAID information, and physical drives information
Backup battery information for the selected MegaRAID controller.
Storage messages.
Admin Menu
Each node in the Admin menu leads to one or more tabs that display in the Work pane. These tabs provides access to the following information:
Admin Menu Node Name
User Management
Work Pane Tabs Provide Information About...
Local User Management, LDAP, and Session Management.
Network, Network Security, and NTP Setting.
Networking
Communication Services Communication Services tab includes HTTP, SSH, XML API,
Redfish Properties, IPMI over LAN Properties, SNMP tab includes
SNMP Properties, User Settings, and Trap Destinations, and Mail
Alert tab includes SNTP Properties and SMTP Recipients.
Security Management
Event Management
Certificate Management and Security Configuration.
List of Platform Event Filters
Firmware Management Cisco IMC and BIOS firmware information and management.
8
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Overview
Toolbar
Admin Menu Node Name
Utilities
Device Connector
Work Pane Tabs Provide Information About...
Technical support data collection export to remote and local download, system configuration import and export options,
Generate to NMI host, restore factory defaults settings, add or update Cisco IMC Banner, generate inventory data, export hard inventory data to remote, upload PID catalog, enable or disable secure adapter update.
Intersight management and network settings.
Toolbar
The toolbar displays above the Work pane.
Button Name
Refresh
Description
Refreshes the current page.
Host Power
Launch KVM
Ping
Reboot
Locator LED
Displays the drop-down menu for you to choose power options.
Launches the Launch KVM pop-up window.
Launches the Ping Details pop-up window.
Enables you to reboot Cisco IMC.
Allows you to turn on or turn off the locator LED.
Cisco Integrated Management Controller Online Help Overview
The GUI for the Cisco Integrated Management Controller (Cisco IMC) software is divided into two main sections, a Navigation pane on the left and a Work pane on the right.
This help system describes the fields on each Cisco IMC GUI page and in each dialog box.
To access the page help, do one of the following:
• In a particular tab in the Cisco IMC GUI, click the Help icon in the toolbar above the Work pane.
• In a dialog box, click the Help button in that dialog box.
Note For a complete list of all C-Series documentation, see the Cisco UCS C-Series Servers Documentation Roadmap available at the following URL: http://www.cisco.com/go/unifiedcomputing/c-series-doc .
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
9
Overview
Logging into Cisco IMC
Logging into Cisco IMC
Procedure
Step 1
Step 2
Step 3
In your web browser, type or select the web link for Cisco IMC.
If a security dialog box displays, do the following: a) (Optional) Check the check box to accept all content from Cisco.
b) Click Yes to accept the certificate and continue.
In the log in window, enter your username and password.
Tip When logging in for the first time to an unconfigured system, use password as the password.
admin as the username and
The following situations occur when you login to the Web UI for the first time:
• You cannot perform any operation until you change default admin credentials on the Cisco
IMC Web UI.
• You cannot close or cancel the password change pop-up window and opening it in a tab or refreshing the browser page will continue to display the pop-up window. This pop-up window appears when you login after a factory reset.
• You cannot choose the word 'password' as your new password. If this creates problems for any scripts you may be running, you could change it to password by logging back into the user management options, but this is ENTIRELY at your own risk. It is not recommended by Cisco.
Step 4 Click Log In .
Logging out of Cisco IMC
Procedure
Step 1
Step 2
In the upper right of Cisco IMC, click the gear icon and click Log Out from the drop-down list.
Logging out returns you to the Cisco IMC log in page.
(Optional) Log back in or close your web browser.
10
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
C H A P T E R
2
Installing the Server OS
This chapter includes the following sections:
•
OS Installation Methods, on page 11
•
Virtual KVM Console, on page 11
•
PXE Installation Servers, on page 13
•
Booting an Operating System from a USB Port, on page 14
OS Installation Methods
C-Series servers support several operating systems. Regardless of the OS being installed, you can install it on your server using one of the following tools:
• KVM console
• PXE installation server
For more information on Cisco UCS Server Configuration Utility, see Cisco UCS Server Configuration Utility
Quick Start Guide .
Virtual KVM Console
The vKVM console is an interface accessible from Cisco IMC that emulates a direct keyboard, video, and mouse (vKVM) connection to the server. The vKVM console allows you to connect to the server from a remote location.
Here are a few major advantages of using Cisco KVM Console:
• The Cisco KVM console provides connection to KVM, SOL, and vMedia whereas the Avocent KVM provides connection only to KVM and vMedia.
• In the KVM Console, the vMedia connection is established at the KVM Launch Manager and is available for all users.
• The KVM console offers you an advanced character replacement options for the unsupported characters while pasting text from the guest to the host.
• The KVM console provides you an ability to store the vMedia mappings on CIMC.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
11
Installing the Server OS
Installing an OS Using the KVM Console
Instead of using CD/DVD or floppy drives physically connected to the server, the vKVM console uses virtual media, which are actual disk drives or disk image files that are mapped to virtual CD/DVD or floppy drives.
You can map any of the following to a virtual drive:
• CD/DVD or floppy drive on your computer
• Disk image files (ISO or IMG files) on your computer
• USB flash drive on your computer
• CD/DVD or floppy drive on the network
• Disk image files (ISO or IMG files) on the network
• USB flash drive on the network
You can use the vKVM console to install an OS on the server.
Installing an OS Using the KVM Console
Step 1
Step 2
Step 3
Step 4
Step 5
Step 6
Step 7
Step 8
Step 9
Note This procedure describes only the basic installation steps. Detailed guides for installing Linux, VMware, and
Windows can be found at this URL: http://www.cisco.com/en/US/products/ps10493/products_installation_ and_configuration_guides_list.html
.
Before you begin
• Locate the OS installation disk or disk image file.
• You must log in as a user with admin privileges to install an OS.
Procedure
Load the OS installation disk into your CD/DVD drive, or copy the disk image files to your computer.
If Cisco IMC is not open, log in.
In the Navigation pane, click the Compute menu.
In the Compute menu, select a server.
In the work pane, click the Remote Management tab.
In the Remote Management pane, click the Virtual KVM tab.
In the Actions area, click Launch KVM Console .
The KVM Console opens in a separate window.
From the KVM console, click the VM tab.
In the VM tab, map the virtual media using either of the following methods:
• Check the Mapped check box for the CD/DVD drive containing the OS installation disk.
• Click Add Image , navigate to and select the OS installation disk image, click Open to mount the disk image, and then check the Mapped check box for the mounted disk image.
12
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Installing the Server OS
PXE Installation Servers
Step 10
Note You must keep the VM tab open during the OS installation process. Closing the tab unmaps all virtual media.
Reboot the server and select the virtual CD/DVD drive as the boot device.
When the server reboots, it begins the installation process from the virtual CD/DVD drive. Refer to the installation guide for the OS being installed to guide you through the rest of the installation process.
What to do next
After the OS installation is complete, reset the LAN boot order to its original setting. Always follow your OS vendors recommended configuration, including software interoperability and driver compatibility. For more information on driver recommendations and installation, follow the Cisco UCS Hardware Compatibility list here: https://ucshcltool.cloudapps.cisco.com/public/
PXE Installation Servers
A Preboot Execution Environment (PXE) installation server allows a client to boot and install an OS from a remote location. To use this method, a PXE environment must be configured and available on your VLAN, typically a dedicated provisioning VLAN. Additionally, the server must be set to boot from the network.
When the server boots, it sends a PXE request across the network. The PXE installation server acknowledges the request, and starts a sequence of events that installs the OS on the server.
PXE servers can use installation disks, disk images, or scripts to install an OS. Proprietary disk images can also be used to install an OS, additional components, or applications.
Note PXE installation is an efficient method for installing an OS on a large number of servers. However, considering that this method requires setting up a PXE environment, it might be easier to use another installation method.
Installing an OS Using a PXE Installation Server
Before you begin
• Verify that the server can be reached over a VLAN.
• You must log in as a user with admin privileges to install an OS.
Procedure
Step 1
Step 2
Set the boot order to PXE first.
Reboot the server.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
13
Installing the Server OS
Booting an Operating System from a USB Port
If a PXE install server is available on the VLAN, the installation process begins when the server reboots. PXE installations are typically automated and require no additional user input. Refer to the installation guide for the OS being installed to guide you through the rest of the installation process.
What to do next
After the OS installation is complete, reset the LAN boot order to its original setting. Always follow your OS vendors recommended configuration, including software interoperability and driver compatibility. For more information on driver recommendations and installation, follow the Cisco UCS Hardware Compatibility list here: https://ucshcltool.cloudapps.cisco.com/public/
Booting an Operating System from a USB Port
All Cisco UCS C-series servers support booting an operating system from any USB port on the server. However, there are a few guidelines that you must keep in mind, prior to booting an OS from a USB port.
• To maintain the boot order configuration, it is recommended that you use an internal USB port for booting an OS.
• The USB port must be enabled prior to booting an OS from it.
By default, the USB ports are enabled. If you have disabled a USB port, you must enable it prior to booting an OS from it. For information on enabling a disabled USB ports, see topic Enabling or Disabling the Internal USB Port in the server-specific installation and service guide available at the following link: http://www.cisco.com/en/US/products/ps10493/prod_installation_guides_list.html
.
• After you boot the OS from the USB port, you must set the second-level boot order so that the server boots from that USB source every time.
14
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
C H A P T E R
3
Managing Chassis
This chapter includes the following sections:
•
•
Chassis Summary
Viewing Chassis Summary
By default when you log on to the Cisco UCS C-Series rack-mount server, the Summary pane of the Chassis is displayed in the Web UI. You can also view the Chassis summary when in another tab or working area, by completing the following steps:
Procedure
Step 1
Step 2
Step 3
In the Navigation pane, click the Chassis menu.
In the Chassis menu, click Summary .
In the Server Properties area of the Chassis Summary pane, review the following information:
Name
Product Name field
Description
The model name of the server.
The serial number for the server.
Serial Number field
PID field
UUID field
BIOS version field
The product ID.
The UUID assigned to the server.
The version of the BIOS running on the server.
Slot ID Slot ID of the node in the enclosure.
Note This field is available only on some C-Series servers.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
15
Managing Chassis
Viewing Chassis Summary
Name
Description
Asset Tag field field
Description
A user-defined description for the server.
Following guidelines should be observed while updating Description field.
• Description can not contain the following special characters:
• &
• !
A user-defined tag for the server. By default, the asset tag for a new server displays Unknown .
Following guidelines should be observed while updating Asset Tag field.
• Asset Tag field can have a maximum of 32 characters.
• Asset Tag can not contain the following special characters:
• &
• !
Step 4 In the Cisco IMC Information area of the Chassis Summary pane, review the following information:
Name
Hostname field
Description
A user-defined hostname for the Cisco IMC. By default, the hostname appears in CXXX-YYYYYY format, where XXX is the model number and YYYYYY is the serial number of the server.
IP Address field The IP address for the Cisco IMC.
MAC Address field
Firmware Version
Current Time field field
The MAC address assigned to the active network interface to the Cisco
IMC.
The current Cisco IMC firmware version.
The current date and time according to the Cisco IMC clock.
Note Cisco IMC gets the current date and time from the server
BIOS when the NTP is disabled. When NTP is enabled, Cisco
IMC gets the current time and date from the NTP server. To change this information, reboot the server and press F2 when prompted to access the BIOS configuration menu. Then change the date or time using the options on the main BIOS configuration tab.
Local Time field The local time of the region according to the chosen time zone.
16
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Managing Chassis
Viewing Chassis Summary
Step 5
Name
Timezone field
In the Chassis Status area of the Chassis Summary pane, review the following information:
Name
Power State field
Description
The current power state.
Overall Server Status field The overall status of the server. This can be one of the following:
• Memory Test In Progress —The server is performing a self-test of the installed memory. This condition normally occurs during the boot process.
• Good
• Moderate Fault
• Severe Fault
Temperature field
Description
Allows you to select a time zone by clicking on the Select Timezone option. In the Select Timezone pop-up screen, mouse over the map and click on the location to select your time zone or choose your time zone from the Timezone drop-down menu.
Overall DIMM Status
Power Supplies field field
The temperature status. This can be one of the following:
• Good
• Fault
• Severe Fault
You can click the link in this field to view more temperature information.
The overall status of the memory modules. This can be one of the following:
• Good
• Fault
• Severe Fault
You can click the link in this field to view detailed status information.
The overall status of the power supplies. This can be one of the following:
• Good
• Fault
• Severe Fault
You can click the link in this field to view detailed status information.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
17
Managing Chassis
Viewing Chassis Summary
Name
Fans field
Locator LED field
Front Locator LED field
Overall Storage Status field
Description
The overall status of the power supplies. This can be one of the following:
• Good
• Fault
• Severe Fault
You can click the link in this field to view detailed status information.
Whether the locator LEDs are on or off.
Whether the front panel locator LED on the chassis is on or off.
Note This option is available only on some UCS C-Series servers.
The overall status of all controllers. This can be one of the following:
• Good
• Moderate Fault
• Severe Fault
Step 6 In the Server Utilization area of the Chassis Summary pane, review the following information in a graphical representation:
Name
Overall Utilization (%) field
Description
The overall realtime utilization of CPU, memory, and
IO (input and output) of the system in percentage.
CPU Utilization (%) field
Memory Utilization (%) field
The CPU or computation utilization of the system on all the available CPUs in percentage.
The memory utilization of the system on all the available memory (DIMM) channels in percentage.
IO Utilization (%) field The IO resource utilization of the system in percentage.
18
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Managing Chassis
Chassis Inventory
Chassis Inventory
Viewing Power Supply Properties
Procedure
Step 1
Step 2
Step 3
In the Navigation pane, click the Chassis menu.
In the Chassis menu, click Inventory .
In the Inventory work pane, click the Power Supplies tab and review the following information for each power supply:
Name
Device ID column
Description
The identifier for the power supply unit.
Status
Input column column
Output column
FW Version column
Product ID column
The status of the power supply unit.
The input into the power supply, in watts.
The maximum output from the power supply, in watts.
The firmware version for the power supply.
The product identifier for the power supply assigned by the vendor.
Viewing Cisco VIC Adapter Properties
Procedure
Step 1
Step 2
Step 3
In the Navigation pane, click the Chassis menu.
In the Chassis menu, click Inventory .
In the Inventory work pane, click the Cisco VIC Adapters tab and review the following high level information:
Name
Slot Number column
Description
The PCI slot in which the adapter is installed.
Serial Number column
Product ID column
The serial number for the adapter.
The product ID for the adapter.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
19
Managing Chassis
Viewing SAS Expander Properties
Name
Cisco IMC Enabled column
Description column
Description
Whether the adapter is able to manage Cisco IMC. This functionality depends on the type of adapter installed and how it is configured. For details, see the hardware installation guide for the type of server you are using.
Description of the adapter.
Viewing SAS Expander Properties
Before you begin
The server must be powered on, or the properties will not display.
Procedure
Step 1
Step 2
Step 3
In the Navigation pane, click the Chassis menu.
In the Chassis menu, click Inventory .
In the Inventory work pane, click the SAS Expander tab and review the following information:
Name
ID column
Description
The product ID of the expander.
Name column
Firmware Version column
Secondary Firmware Version column
Server Up Link Speed column
The name of the expander.
The firmware version the expander uses.
The secondary firmware version of the expander.
Up link speed received with the LSI RAID Controller.
Note This is available only on some C-Series servers.
Enabling 6G or 12G Mixed Mode on a SAS Expander
You can enable or disable a 6 gigabyte or 12 gigabyte mixed mode speed support for a card using this option, which is a toggle button.
Note This option is available only on some C-Series servers.
20
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Managing Chassis
Viewing Storage Properties
Procedure
Step 1
Step 2
Step 3
Step 4
Step 5
In the Navigation pane, click the Chassis menu.
In the Chassis menu, click Inventory .
In the Inventory working area, click the SAS Expander tab.
In the SAS Expander working area, click Enable 6G-12G Mixed Mode .
(Optional) Click Disable 6g-12G Mixed Mode to disable the feature.
Viewing Storage Properties
Before you begin
The server must be powered on, or the properties will not display.
Procedure
Step 1
Step 2
Step 3
In the Navigation pane, click the Chassis menu.
In the Chassis menu, click Inventory .
In the Inventory work pane, click the Storage tab and review the following information:
Name
Controller field
Description
PCIe slot in which the controller drive is located.
PCI Slot field
Product Name field
Serial Number field
Firmware Package Build field
Product ID field
The name of the PCIe slot in which the controller drive is located.
Name of the controller.
The serial number of the storage controller.
The active firmware package version number.
Product ID of the controller.
Battery Status field
Cache Memory Size field
Health field
Status of the battery.
The size of the cache memory, in megabytes.
The health of the controller firmware status.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
21
Managing Chassis
Viewing Network Adapter Properties
Viewing Network Adapter Properties
Before you begin
The server must be powered on, or the properties will not display.
Procedure
Step 1
Step 2
Step 3
In the Navigation pane, click the Chassis menu.
In the Chassis menu, click Inventory .
In the Inventory work pane, click the Network Adapters tab and review the following information:
Name
Slot column
Description
The slot in which the adapter is installed.
The product name for the adapter.
Product Name column
Number of Interfaces column
External Ethernet Interfaces
The number of interfaces for the adapter.
ID —The ID for the external ethernet interface.
MAC Address —The MAC address for the external ethernet interface.
Viewing GPU Inventory
The GPU Inventory option is available only on some C-Series servers.
Before you begin
The server must be powered on, or the properties will not display.
Procedure
Step 1
Step 2
Step 3
In the Navigation pane, click the Chassis menu.
In the Chassis menu, click Inventory .
In the Inventory work pane, click the GPU Inventory tab and review the following information:
Name
Slot
Description
Slot in which the GPU is installed.
Product Name
Number of GPUs
Name of the GPU.
Number of GPUs present in the slot.
22
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Managing Chassis
Viewing PCI Switch Info
Viewing PCI Switch Info
Before you begin
The server must be powered on, or the properties will not display.
Procedure
Step 1
Step 2
Step 3
In the Navigation pane, click the Chassis menu.
In the Chassis menu, click Inventory .
In the Inventory work pane, click the PCI Switch Info tab and review the following information:
Name
Controller column
Description
PCI Slot in which the controller is present.
Type of PCI switch present in the slot.
Controller Type column
Product Name column
Manufacturer column
Vendor ID column
Name of the PCI switch.
Manufacture of the PCI switch.
The switch ID assigned by the vendor.
The secondary switch ID assigned by the vendor.
Sub Vendor ID column
Device ID column
Sub Device ID column
The device ID assigned by the vendor.
The secondary device ID assigned by the vendor.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
23
Viewing PCI Switch Info
Managing Chassis
24
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
C H A P T E R
4
Managing the Server
This chapter includes the following sections:
•
•
Configuring Power Policies, on page 40
•
Configuring DIMM Blacklisting, on page 56
•
Enabling DIMM Black Listing, on page 57
•
Configuring BIOS Settings, on page 57
•
•
Setting Dynamic Front Panel Temperature Threshold, on page 63
•
Persistent Memory Modules, on page 63
Server Boot Order
Using Cisco IMC, you can configure the order in which the server attempts to boot from available boot device types. In the legacy boot order configuration, Cisco IMC allows you to reorder the device types but not the devices within the device types. With the precision boot order configuration, you can have a linear ordering of the devices. In the web UI or CLI you can change the boot order and boot mode, add multiple devices under each device types, rearrange the boot order, set parameters for each device type.
When you change the boot order configuration, Cisco IMC sends the configured boot order to BIOS the next time that server is rebooted. To implement the new boot order, reboot the server after you make the configuration change. The new boot order takes effect on any subsequent reboot. The configured boot order remains until the configuration is changed again in Cisco IMC or in the BIOS setup.
Note The actual boot order differs from the configured boot order if either of the following conditions occur:
• BIOS encounters issues while trying to boot using the configured boot order.
• A user changes the boot order directly through BIOS.
• BIOS appends devices that are seen by the host but are not configured from the user.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
25
Managing the Server
Server Boot Order
Important While upgrading Cisco UCS C220 M5 or C480 M5 servers to release 4.1(1x) under the following conditions:
• if you are upgrading from any release earlier than 4.0(4x)
• if Legacy Boot Mode is enabled and no Cisco IMC Boot Order is configured
• and, if the server is booting from Cisco HWRAID adapter then, you should perform one of the following before upgrading:
• Run XML-API scripts and UCSCFG based scripts provided here.
OR
• Manually configure the intended boot order through Cisco IMC GUI or CLI interfaces.
Note When you create a new policy using the configure boot order feature, BIOS tries to map this new policy to the devices in the system. It displays the actual device name and the policy name to which it is mapped in the
Actual Boot Order area. If BIOS cannot map any device to a particular policy in Cisco IMC, the actual device name is stated as NonPolicyTarget in the Actual Boot Order area.
Note During Cisco IMC 2.0(x) upgrade, the legacy boot order is migrated to the precision boot order. The previous boot order configuration is erased and all device types configured before updating to 2.0 version are converted to corresponding precision boot device types and some dummy devices are created for the same device types.
you can view these devices in the Configured Boot Order area in the web UI. To view these devices in the
CLI, enter show boot-device command. During this the server's actual boot order is retained and it can be viewed under actual boot order option in web UI and CLI.
When you downgrade Cisco IMC prior to 2.0(x) verison the server's last legacy boot order is retained, and the same can be viewed under Actual Boot Order area. For example:
• If you configured the server in a legacy boot order in 2.0(x) version, upon downgrade a legacy boot order configuration is retained.
• If you configured the server in a precision boot order in 2.0(x), upon downgrade the last configured legacy boot order is retained.
Important • Boot order configuration prior to 2.0(x) is referred as legacy boot order. If your running version is 2.0(x), then you cannot configure legacy boot order through web UI, but you can configure through CLI and
XML API. In the CLI, you can configure it by using set boot-order HDD,PXE command. Even though, you can configure legacy boot order through CLI or XML API, in the web UI this configured boot order is not displayed.
• Legacy and precision boot order features are mutually exclusive. You can configure either legacy or precision boot order. If you configure legacy boot order, it disables all the precision boot devices configured. If you configure precision boot order, then it erases legacy boot order configuration.
26
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Managing the Server
Configuring the Precision Boot Order
Configuring the Precision Boot Order
Before you begin
You must log in as a user with admin privileges to configure server the boot order.
Procedure
Step 1
Step 2
Step 3
Step 4
In the Navigation pane, click the Compute menu.
In the BIOS tab, click the Configure Boot Order tab.
In the BIOS Properties area, click Configure Boot Order at the bottom of the page.
Configure Boot Order dialog box is displayed.
In the Configure Boot Order dialog box, update the following properties:
Basic Tab
Name
Device Types table
Description
The server boot options. You can select one or more of the following:
• HDD —Hard disk drive
• FDD —Floppy disk drive
• CDROM —Bootable CD-ROM or DVD
• PXE —PXE boot
• EFI —Extensible Firmware Interface
>>
<<
Boot Order
Down
Up table
Save Changes
Close button
Moves the selected device type to the Boot Order table.
Removes the selected device type from the Boot Order table.
Displays the device types from which this server can boot, in the order in which the boot will be attempted.
Moves the selected device type to a higher priority in the Boot Order table.
Moves the selected device type to a higher priority in the Boot Order table.
Click this button to save the changes made.
Closes the dialog box without saving any changes and the existing configuration is applied when the server is rebooted.
Advanced Tab
The following list of links are displayed under Add Boot Device pane.
• Add Local HDD
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
27
Managing the Server
Managing a Boot Device
Step 5
• Add PXE Boot
• Add SAN Boot
• Add iSCSI Boot
• Add USB
• Add Virtual Media
• Add PCHStorage
• Add UEFISHELL
• Add NVME
• Add Local CDD
• Add HTTP Boot
In the Advanced Boot Order Configuration pane, the devices are displayed after they are added. You can perform the following actions by selecting the appropriate buttons:
• Enable or Disable
• Modify
• Delete
• Clone
• Re-Apply
• Move Up
• Move Down
Click Save Changes .
Additional device types might be appended to the actual boot order, depending on what devices you have connected to your server.
What to do next
Reboot the server to boot with your new boot order.
Managing a Boot Device
Before you begin
You must log in as a user with admin privileges to add device type to the server boot order.
28
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Managing the Server
Managing a Boot Device
Procedure
Step 1
Step 2
Step 3
Step 4
In the Navigation pane, click the Compute menu.
In the BIOS tab, click the Configure Boot Order tab.
In the BIOS Properties area, click Configure Boot Order .
A dialog box with boot order instructions appears.
In the Configure Boot Order dialog box, from the Add Boot Device table, choose the device that you want add to the boot order.
To add the local HDD device, click Add Local HDD , and update the following parameters:
Name
Name field
Description
The name of the device.
Note Once created, you cannot rename the device.
State drop-down list The visibility of the device by BIOS. This can be one of the following:
• Enabled —The device is visible to BIOS in a boot order configuration.
• Disabled —The device is not visible to BIOS in a boot configuration.
Order
Slot field field
Add Device
Cancel button button
The order of the device in the available list of devices.
Enter between 1 and n, where n is the number of devices.
The slot in which the device is installed. Enter the slot number from the available range.
Adds the device to the Boot Order table.
Closes the dialog box without saving any changes made while the dialog box was open.
To add the PXE device, click Add PXE , and update the following parameters:
Name
Name field
Description
The name of the device.
This name cannot be changed after the device has been created.
State drop-down list The visibility of the device by BIOS. The state can be one of the following:
• Enabled —The device is visible to BIOS in a boot order configuration.
• Disabled —The device is not visible to BIOS in a boot order configuration.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
29
Managing the Server
Managing a Boot Device
Name
Order field
MAC Address
Description
The order of the device in the available list of devices.
Enter between 1 and n, where n is the number of devices.
MAC address of the network ethernet interface.
Note This option is available only on some C-Series servers.
Slot
Port field field
The slot in which the device is installed. Enter the slot number from the available range.
The port of the slot in which the device is present.
Enter a number between 0 and 255.
To add the SAN boot device, click Add SAN Boot , and update the following parameters:
Name
Name field
Description
The name of the device.
This name cannot be changed after the device has been created.
State drop-down list The visibility of the device by BIOS. The state can be one of the following:
• Enabled —The device is visible to BIOS in a boot order configuration.
• Disabled —The device is not visible to BIOS in a boot order configuration.
Order
Slot
LUN field field field
Save Changes
Cancel button button
The order of the device in the available list of devices.
Enter between 1 and n, where n is the number of devices.
The slot in which the device is installed. Enter the slot number from the available range.
Logical unit in a slot where the device is present.
Enter a number between 0 and 255.
Adds the device to the Boot Order table, and saves the changes.
Closes the dialog box without saving any changes made while the dialog box was open.
To add the iSCSI boot device, click Add iSCSI Boot , and update the following parameters:
Name
Name field
Description
The name of the device.
This name cannot be changed after the device has been created.
30
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Managing the Server
Managing a Boot Device
Name
State
Order
Slot
Port drop-down list field field field
Description
The visibility of the device by BIOS. The state can be one of the following:
• Enabled —The device is visible to BIOS in a boot order configuration.
• Disabled —The device is not visible to BIOS in a boot order configuration.
The order of the device in the available list of devices.
Enter between 1 and n, where n is the number of devices.
The slot in which the device is installed. Enter the slot number from the available range.
The port of the slot in which the device is present.
Enter a number between 0 and 255.
Note In case of a VIC card, use a vNIC instance instead of the port number.
Save Changes
Cancel button button Adds the device to the Boot Order table, and saves the changes.
Closes the dialog box without saving any changes made while the dialog box was open.
To add the SD card, click Add SD Card , and update the following parameters:
Note This option is available only on some UCS C-Series servers.
Name
Name field
State
Order drop-down list field
Save Changes
Cancel button button
Description
The name of the device.
This name cannot be changed after the device has been created.
The visibility of the device by BIOS. This can be one of the following:
• Enabled —The device is visible to BIOS in a boot order configuration.
• Disabled —The device is not visible to BIOS in a boot configuration.
The order of the device in the available list of devices.
Enter between 1 and n, where n is the number of devices.
Adds the device to the Boot Order table.
Closes the dialog box without saving any changes made while the dialog box was open.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
31
Managing the Server
Managing a Boot Device
To add the USB device, click Add USB , and update the following parameters:
Name
Name field
Description
The name of the device.
This name cannot be changed after the device has been created.
Sub Type drop-down list The subdevice type under a certain device type. This can be one of the following:
• CD
• FDD
• HDD
State drop-down list The visibility of the device by BIOS. This can be one of the following:
• Enabled —The device is visible to BIOS in a boot order configuration.
• Disabled —The device is not visible to BIOS in a boot order configuration.
Order field
Save Changes
Cancel button button
The order of the device in the available list of devices.
Enter between 1 and n, where n is the number of devices.
Adds the device to the Boot Order table.
Closes the dialog box without saving any changes made while the dialog box was open.
To add the virtual media, click Virtual Media , and update the following parameters:
Name
Name field
Description
The name of the device.
This name cannot be changed after the device has been created.
Sub Type drop-down list The subdevice type under a certain device type. This could be any one of the following:
• KVM Mapped DVD
• Cisco IMC Mapped DVD
• KVM Mapped HDD
• Cisco IMC Mapped HDD
• KVM Mapped FDD
32
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Managing the Server
Managing a Boot Device
Name
State drop-down list
Order field
Save Changes
Cancel button button
The order of the device in the available list of devices.
Enter between 1 and n, where n is the number of devices.
Adds the device to the Boot Order table.
Closes the dialog box without saving any changes made while the dialog box was open.
To add the PCH storage device, click PCH Storage , and update the following parameters:
Name
Name field
Description
The name of the device.
This name cannot be changed after the device has been created.
State drop-down list The visibility of the device by BIOS. This can be one of the following:
• Enabled —The device is visible to BIOS in a boot order configuration.
• Disabled —The device is not visible to BIOS in a boot order configuration.
Order field
LUN field
Description
The visibility of the device by BIOS. The state can be one of the following:
• Enabled —The device is visible to BIOS in a boot order configuration.
• Disabled —The device is not visible to BIOS in a boot order configuration.
The order of the device in the available list of devices.
Enter between 1 and n, where n is the number of devices.
Logical unit in a slot where the device is present.
• Enter a number between 0 and 255
• SATA in AHCI mode—Enter a value between 1 and 10
• SATA in SWRAID mode—Enter 0 for SATA , and enter 1 for
SATA
Note SATA mode is available only on some UCS C-Series servers.
Save Changes
Cancel button button Adds the device to the Boot Order table.
Closes the dialog box without saving any changes made while the dialog box was open.
To add the UEFI shell device, click Add UEFI Shell , and update the following parameters:
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
33
Managing the Server
Managing a Boot Device
Name
Name
State field drop-down list
Description
The name of the device.
This name cannot be changed after the device has been created.
The visibility of the device by BIOS. The state can be one of the following:
• Enabled —The device is visible to BIOS in a boot order configuration.
• Disabled —The device is not visible to BIOS in a boot order configuration.
Order field
Add Device
Cancel button button
The order of the device in the available list of devices.
Enter between 1 and n, where n is the number of devices.
Adds the device to the Boot Order table.
Closes the dialog box without saving any changes made while the dialog box was open.
To add the HTTP boot device device, click Add HTTP Boot , and update the following parameters:
Note The following OS (ISOs) are supported for HTTP Boot device:
• SLES 12.x
• RHEL 8.2
• ESX 6.5
The following OS (ISOs) are not supported for HTTP Boot device:
• Windows 2016
• Windows 2019
Name
Name field
State drop-down list
Description
The name of the device.
This name cannot be changed after the device has been created.
You can enter between 1 and 30 characters, containing alphanumerics,
- (hyphen) and _ (underscore). The name cannot begin with hyphen or underscore.
The visibility of the device by BIOS. The state can be one of the following:
• Enabled —The default option. The device is visible to BIOS in a boot order configuration.
• Disabled —The device is not visible to BIOS in a boot order configuration.
34
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Managing the Server
Managing a Boot Device
Name
Order field
MAC Address field
IP Type drop-down list
Slot
Port field field
Description
The order of the device in the available list of devices. The default option is 1.
MAC address of the network ethernet interface.
The type of IP.
Select any one of the following options displayed in the drop-down list:
• None
• IPv4
• IPv6
The default value is None.
The slot in which the device is installed. Enter the slot number from the available range.
Enter the required value from the below list:
• OCP
• MLOM
• L
• Any number between 1 and 255
The port of the slot in which the device is present.
Enter a number between 0 and 255.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
35
Managing the Server
Overview to UEFI Secure Boot
Name
IP Config Type drop-down list
URI field
Save Changes
Cancel button button
Description
The type of IP configuration.
The following options are displayed in the drop-down list:
• None
• DHCP
• Static
For DHCP IP configuration, the following fields are displayed, depending on the IP type that you have selected:
• MAC Address
• IP Type
• Slot
• Port
For Static IP configuration, the following fields are displayed, depending on the IP type that you have selected:
• URI
• IP Address
• IPv4 Netmask or IPv6 Netmask
• IPv4 Gateway or IPv6 Gateway
• IPv4 Preferred DNS server or IPv6 Preferred DNS server
The Uniform Resource Identifier HTTP server path location.
You can enter between 1 and 255 characters.
Saves the changes and adds the device to the Boot Order table.
Closes the dialog box without saving any changes made while the dialog box was open.
Overview to UEFI Secure Boot
You can use Unified Extensible Firmware Interface (UEFI) secure boot to ensure that all the EFI drivers, EFI applications, option ROM or operating systems prior to loading and execution are signed and verified for authenticity and integrity, before you load and execute the operating system. You can enable this option using either web UI or CLI. When you enable UEFI secure boot mode, the boot mode is set to UEFI mode and you cannot modify the configured boot mode until the UEFI boot mode is disabled.
36
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Managing the Server
Overview to UEFI Secure Boot
Note If you enable UEFI secure boot on a nonsupported OS, on the next reboot, you cannot boot from that particular
OS. If you try to boot from the previous OS, an error is reported and recorded the under system software event in the web UI. You must disable the UEFI secure boot option using Cisco IMC to boot from your previous
OS.
Important Also, if you use an unsupported adapter, an error log event in Cisco IMC SEL is recorded. The error messages is displayed that says:
System Software event: Post sensor, System Firmware error. EFI Load Image Security Violation. [0x5302] was asserted .
UEFI secure boot is supported on the following components:
Components
Supported OS
Types
• Windows Server 2019
• Windows Server 2016
• ESX 6.7
• ESX 6.5
• ESXi 7.0
• Linux
Broadcom PCI adapters
Intel PCI adapters
QLogic PCI adapters
• 5709 dual and quad port adapters
• 57712 10GBASE-T adapter
• 57810 CNA
• 57712 SFP port
• i350 quad port adapter
• X520 adapter
• X540 adapter
• LOM
• 8362 dual port adapter
• 2672 dual port adapter
Fusion-io
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
37
Managing the Server
Enabling UEFI Secure Boot
Components
LSI
Types
• LSI MegaRAID SAS 9240-8i
• LSI MegaRAID SAS 9220-8i
• LSI MegaRAID SAS 9265CV-8i
• LSI MegaRAID SAS 9285CV-8e
• LSI MegaRAID SAS 9285CV-8e
• LSI MegaRAID SAS 9266-8i
• LSI SAS2008-8i mezz
• LSI Nytro card
Enabling UEFI Secure Boot
Procedure
Step 1
Step 2
Step 3
Step 4
In the Navigation pane, click the Compute menu.
In the work pane, click the BIOS tab.
In the BIOS Properties area of the Configure Boot Order tab, check UEFI Secure Boot checkbox.
Note If checked, the boot mode is set to UEFI secure boot. You cannot modify the Configure Boot Mode until UEFI secure boot option is disabled.
If you enable UEFI secure boot on a nonsupported OS, on the next reboot, you cannot boot from that particular
OS. If you try to boot from the previous OS, an error is reported and recorded under the system software event in the web UI. You must disable the UEFI secure boot option by using Cisco IMC to boot from your previous
OS.
Click Save Changes .
What to do next
Reboot the server to have your configuration boot mode settings take place.
Disabling UEFI Secure Boot
Procedure
Step 1
Step 2
Step 3
In the Navigation pane, click the Compute menu.
In the work pane, click the BIOS tab.
In the BIOS Properties area, uncheck the UEFI Secure Boot check box.
38
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Managing the Server
Viewing the Actual Server Boot Order
Step 4 Click Save Changes .
What to do next
Reboot the server to have your configuration boot mode settings take place.
Viewing the Actual Server Boot Order
The actual server boot order is the boot order actually used by BIOS when the server last booted. The actual boot order can differ from the boot order configured in Cisco IMC.
Procedure
Step 1
Step 2
Step 3
In the Navigation pane, click the Compute menu.
In the BIOS tab, click the Configure Boot Order tab.
In the BIOS Properties area, click Configure Boot Order .
This area displays the boot order devices configured through Cisco IMC as well as the actual boot order used by the server BIOS.
The Configured Boot Devices section displays the boot order ( Basic or Advanced ) configured through Cisco
IMC. If this configuration changes, Cisco IMC sends this boot order to BIOS the next time that server boots.
The Basic configuration allows you to specify only the device type. The Advanced configuration allows you to configure the device with specific parameters such as slot, port and LUN.
To change the configured boot order, or to restore the previously configured boot order, administrators can click the Configure Boot Order button. To have these changes take effect immediately, reboot the server.
You can verify the new boot order by refreshing the BIOS tab.
Note This information is only sent to BIOS the next time the server boots. Cisco IMC does not send the boot order information to BIOS again until the configuration changes.
The Actual Boot Devices section displays the boot order actually used by BIOS when the server last booted.
The actual boot order will differ from the configured boot order if either of the following conditions occur:
• The BIOS encounters issues while trying to boot using the configured boot order.
• A user changes the boot order directly through the BIOS. To override any manual changes, you can change the configured boot order through Cisco IMC and reboot the server.
Note When you create a new policy using the configured boot order, BIOS tries to map this new policy to the device or devices present in the system. It displays the actual device name and the policy name to which it is mapped under the Actual Boot Order area. If BIOS cannot map any device found to a particular policy in Cisco IMC, then the actual device name is stated as NonPolicyTarget under the Actual Boot Order area.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
39
Managing the Server
Configuring a Server to Boot With a One-Time Boot Device
Configuring a Server to Boot With a One-Time Boot Device
You can configure a server to boot from a particular device only for the next server boot, without disrupting the currently configured boot order. Once the server boots from the one time boot device, all its future reboots occur from the previously configured boot order.
Before you begin
You must log in as a user with admin privileges to configure server the boot order.
Procedure
Step 1
Step 2
Step 3
In the Navigation pane, click the Compute menu.
In the BIOS tab, click the Configure Boot Order tab.
In the BIOS Properties area, select an option from the Configured One Time Boot Device drop-down.
Note The host boots to the one time boot device even when configured with a disabled advanced boot device.
Creating a Server Asset Tag
Before you begin
You must log in with user or admin privileges to perform this task.
Procedure
Step 1
Step 2
Step 3
Step 4
In the Navigation pane, click the Chassis menu.
In the Chassis menu, click Summary .
In the Server Properties area, update the Asset Tag field.
Click Save Changes .
Configuring Power Policies
Power Capping
Important This section is valid only for some UCS C-Series servers.
40
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Managing the Server
Setting Power Redundancy Policy
Power capping determines how server power consumption is actively managed. When you enable power capping option, the system monitors power consumption and maintains the power below the allocated power limit. If the server cannot maintain the power limit or cannot bring the platform power back to the specified power limit within the correction time, power capping performs actions that you specify in the Action field under the Power Profile area.
Once power capping is enabled, you can configure multiple power profiles to either have standard or advanced power profiles with defined attributes. If you choose a standard power profile, you can set the power limit, correction time, corrective-action, suspend period, hard capping, and policy state (if enabled). If you choose an advanced power profile, in addition to the attributes of the standard power profile, you can also set the domain specific power limits, safe throttle level, and ambient temperature based power capping attributes.
Note The following changes are applicable for Cisco UCS C-Series release 2.0(13) and later:
• After upgrading to the 2.0(13) release, power characterization automatically runs during the first host power on. Subsequent characterization runs only if initiated as described in section Run Power
Characterization section.
• Also, when a server is power cycled and there is a change to the CPU or DIMM configurations, power characterization automatically runs on first host boot. For any other hardware change like PCIe adapters,
GPU or HDDs, power characterization does not run. The characterized power range is modified depending on the components present after the host power cycle.
The Run Power Characterization option in the Power Cap Configuration Tab of the Web UI power cycles the host and starts power characterization.
Setting Power Redundancy Policy
Procedure
Step 1
Step 2
Step 3
Step 4
In the Navigation pane, click the Chassis menu.
In the Chassis menu, click Sensors .
In the Sensors working area, click the Power Supply tab.
Review the following sensor properties for power supply:
Properties Area
Name
Redundancy Status field
Description
The power supply redundancy status.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
41
Managing the Server
Enabling Power Characterization
Name
Redundancy Policy field
Description
The power supply redundancy policy. This can be one of the following:
• Non-Redundant - N, the available PSU output capacity, equals the number of PSUs installed, where PSU failure or grid failure is not supported.
• N+1 - N, the available PSU output capacity, equals the number of
PSUs installed minus 1 (N-1), where the single PSU failure is supported, but grid failure is not supported.
• Grid - N, the available PSU output capacity, equals half the number of PSUs installed (N/2), where N PSU failure or grid failure is supported. This policy implies that the you have connected N number of PSUs to one feed and the other N number of PSUs to another feed.
Enabling Power Characterization
You can enable power characterization only on some Cisco UCS C-Series servers.
Before you begin
You must log in with admin privileges to perform this task.
Procedure
Step 1
Step 2
Step 3
In the Navigation pane, click the Chassis menu.
In the Chassis menu, click Power Management .
In the Power Cap Configuration tab, click the Run Power Characterization link.
A confirmation box appears that says the host is going to be either powered on or rebooted depending on the current power state. Review the message and click OK to close the dialog box.
You can verify the progress of the power characterization in the Status field. The status can be one of the following:
• Not Run —When power characterization has not been run at all since the factory reset.
• Running —When a power characterization process is in progress.
• Completed Successfully —When a power characterization has run successfully.
• Using Defaults —After running the power characterization, if the system fails to obtain the valid values, it uses default value as the recommended maximum and minimum power for power capping.
After power characterization action is performed, the platform power limit range is populated under the
Recommended Power Cap area as a minimum and maximum power in watts.
42
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Managing the Server
Enabling Power Capping
Three values for power capping limits are displayed: Minimum (Allow Throttling) , Minimum (Efficient) and Maximum :
• Minimum (Allow Throttling) - This is the lower power limit for the chassis, when the CPU throttling is enabled.
Note You can use this minimum power limit value only when the enabled.
Allow Throttle checkbox is
• Minimum (Efficient) - This is the lower power limit for the chassis, when the CPU throttling is disabled.
• Maximum - This is the upper power limit for the chassis.
Enabling Power Capping
This option is available only on some Cisco UCS C-Series servers.
Before you begin
• You must log in with admin privileges to perform this task.
• Run power characterization.
Procedure
Step 1
Step 2
Step 3
Step 4
In the Navigation pane, click the Chassis menu.
In the Chassis menu, click Power Management .
Check the Power Capping check box.
Note This is the global option to enable or disable power capping. You must enable this option if you want to configure power profile settings.
Click Save Changes .
Power Profiles
You can configure multiple profiles and set the attributes. These profiles are configured by using either the web UI or CLI. In the web UI, the profiles are listed under the Power Capping area. In the CLI, the profiles are configured when you enter the power-cap-config command. You can configure the following power profiles for power capping feature:
• Standard —Enables you to set a power limit for the platform domain.
• Advanced —Enables you to set various attributes such as the power limiting policy, fail-safe power limiting policy, and the ambient temperature-based power limiting policy.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
43
Managing the Server
Configuring Standard Power Profiles Settings
Configuring Standard Power Profiles Settings
This option is available only on some Cisco UCS C-Series servers.
Before you begin
• You must enable power capping.
• You must log in with admin privileges to perform this task.
Procedure
Step 1
Step 2
Step 3
In the Navigation pane, click the Chassis menu.
In the Chassis menu, click Power Management .
In the Power Profiles area, complete the following fields:
Name
Name field
Description
The name of the profile selected to set the attributes for power capping.
Enable Profile check box
Allow Throttle check box
Enables the power profile for editing.
Correction Time field
If checked, it forces the processor to use more aggressive power management mechanisms such as,
CPU the throttling states (T-states) and memory bandwidth throttling to maintain the power limit, in addition to the regular internal mechanisms.
The time in seconds in which the platform power should be brought back to the specified power limit before taking the action specified in the Action field.
The range is from 1 and 600.
This range varies depending on the server PSU value.
Note The supported minimum correction time for all PSU models is 1 second, except for
DPST-1400AB and DPST-1200DB PSU models for which the supported minimum correction time is 3 seconds.
Action drop-down list The action to be performed if the specified power limit is not maintained within the correction time.
• Alert —Logs the event to the Cisco IMC SEL.
• Alert and Shutdown —Logs the event to the
Cisco IMC SEL, and gracefully shuts down the host.
44
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Managing the Server
Configuring Advanced Power Profile Settings
Name
Power Limit check box
Set Hard Cap check box
Description
The power limit for the server.
Enter power in watts within the range specified.
If checked, ensure that no platform consumption occurs beyond the set power capping value. The platform power consumption is maintained at a safe offset margin below the configured power cap value.
Step 4 Click Save Changes .
Configuring Advanced Power Profile Settings
This option is available only on some Cisco UCS C-Series servers
Before you begin
• You must enable power capping.
• You must log in with admin privileges to perform this task.
Procedure
Step 1
Step 2
Step 3
Step 4
In the Navigation pane, click the Chassis menu.
In the Chassis menu, click Power Management .
From the Power Profiles table in the Power Cap Configuration tab, choose the Advanced profile.
In addition to the standard profile settings, the Domain Specific Power Limit , Safe Throttle Level , and
Ambient Temperature Based Power Capping areas are displayed.
In the Domain Specific Power Limit area, complete the following fields:
Name
CPU field
Description
The power limit for the CPU.
Enter power in watts within the range specified.
Memory field The power limit for the memory.
Enter power in watts within the range specified.
Note This field is not available on servers with
Intel
®
Optane
™
DC persistent memory modules.
Platform field The power limit for the platform.
Enter power in watts within the range specified.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
45
Managing the Server
Resetting Power Profiles to Default
Step 5
Step 6
Step 7
Step 8
In the Suspend Period area, click Configure to configure a suspend period for a specific time period and day.
In the Safe Throttle Level area, complete the following fields:
Name
Failsafe Timeout field
Description
The safe throttle policy that is applied when power capping is impacted due to internal faults such as missing power readings for platforms or CPUs.
Enter value in seconds
Platform field The throttling level for the platform.
The range is from 0 to 100 percentage.
In the Ambient Temperature Based Power Capping area, complete the following fields:
Name
Platform Temp Trigger field
Description
The inlet (front panel) temperature sensor value in
Celsius.
Note When the inlet temperature on the platform exceeds the specified limit, the system uses the thermal power value as the power capping limit.
The power limit to be maintained in watts.
Thermal Power Limit field
Click Save Changes .
Resetting Power Profiles to Default
This option is available only on some Cisco UCS C-Series servers.
Before you begin
You must log in with admin privileges to perform this task.
Procedure
Step 1
Step 2
Step 3
Step 4
In the Navigation pane, click the Chassis menu.
In the Chassis menu, click Power Management .
In the Power Profiles area, click the Reset Profiles to Default button.
Note This action resets all the power profile settings to factory default values and disables power capping.
Click Save Changes .
46
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Managing the Server
Power Monitoring
Power Monitoring
Power monitoring is initiated from the time the host is either powered on or booted. This feature collects the power consumption statistics for a platform, CPU, and memory domains and provides a minimum, maximum, and averaged reading for the duration that is being collected. These readings can be used to calculate the power consumption trends of the domains. Cisco IMC collects and stores these power consumption statistic values to plot graphs for various time periods (such as an hour, a day, and a week).
Note You cannot create additional statistics collection policies or delete the existing monitoring policies. You can only modify the default policies.
Viewing Power Monitoring Summary
This option is available only on some Cisco UCS C-Series servers.
Procedure
Step 1
Step 2
Step 3
Step 4
Step 5
In the Navigation pane, click the Chassis menu.
In the Chassis menu, click Power Management .
On the Work pane, click the Power Monitoring tab.
In the Power Monitoring Summary area, review the following information:
The following tables display the power consumed by the system and its components since the last time it was rebooted.
Name
Monitoring Period
Description
The time of monitoring the power consumed by the system since the last time it was rebooted.
The monitoring period is displayed in Day HH:MM:SS format.
Note Monitoring Period is displayed under Chassis .
Platform , CPU , and Memory areas are available under Server 1 and Server 2 .
In the Platform area, review the following information:
Name
Current
Description
The power currently being used by the server, CPU, and memory in watts.
Minimum
Maximum
The minimum number of watts consumed by the server, CPU, and memory since the last time it was rebooted.
The maximum number of watts consumed by the server, CPU, and memory since the last time it was rebooted.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
47
Managing the Server
Viewing Power Monitoring Summary
Step 6
Step 7
Step 8
Name
Average
Description
The average amount of power consumed by the server, CPU, and memory in watts over the defined period of time.
In the CPU area, review the following information:
Name
Current
Description
The power currently being used by the CPU in watts.
Minimum
Maximum
The minimum number of watts consumed by the CPU since the last time it was rebooted.
The maximum number of watts consumed by the CPU since the last time it was rebooted.
Average The average amount of power consumed by the server, CPU, and memory in watts over the defined period of time.
In the Memory area, review the following information:
Name
Current
Description
The power currently being used by the memory, in watts.
Minimum
Maximum
Average
The minimum number of watts consumed by the memory since the last time it was rebooted.
The maximum number of watts consumed by the memory since the last time it was rebooted.
The average amount of power consumed by the memory in watts over the defined period of time.
In the Chart Properties area, review and update the chart, component, and view the power consumption details.
Name
Chart Settings
Description
Enables you to configure the chart properties and the way data is displayed in the chart.
Download Power Statistics and
Server Utilization Data
Enables you to download the power statistics and host server utilization information. The files are downloaded to your local download folder.
Note If the file size of the already downloaded statistics file is less than 256 KB, then when you download, another set of files is downloaded, one for the power statistics and the other for host server utilization. If the size of the existing files exceeds
256 KB, then the next set of files overwrites the existing ones.
48
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Managing the Server
Viewing Power Monitoring Summary
Name
Chart drop-down list
Component drop-down list
Domain drop-down list
Plot button
Chart/Table View (Appears on mouse-over)
Chart Type (Appears on mouse-over)
Description
Allows you to collect the trends of power consumption from every server for the selected duration. This can be one of the following:
• Last Hour — Plots the chart for every five minutes
• Last Day —Plots the chart for every hour from the current time.
• Last Week —Plots the chart for each day.
The component for which you want to view the power consumption over the selected duration. This can be one of the following:
• Chassis
• Server 1
• Server 2
The default value displayed is Platform .
Displays the power consumed by the selected component for the specified duration.
Select to view power monitoring summary in either
Chart or Table view.
Select the type of chart you wish to view. This could be one of the following:
• Line Chart— Power monitoring data appears in lines.
• Column Chart— Power monitoring data appears as a column.
Default Chart : Line Chart.
Note When the Chart drop-down list is selected as Last Week , and more than one
Component is selected, the Column chart is not displayed, and by default the Line chart is displayed. The following message is displayed in such a scenario: For the selected Configuration,
Column graph cannot be plotted. Reverting to Line
Graph.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
49
Managing the Server
Viewing the Power Statistics in a Chart
Name
Current check box
Average check box
Maximum check box
Minimum check box
Description
If checked, the chart displays the current power consumed by the selected component for the selected duration.
If checked, the plot displays the average amount of power consumed by the selected component for the selected duration.
If checked, the plot displays the maximum number of watts consumed by the selected component for the selected duration.
If checked, the plot displays the minimum number of watts consumed by the selected component for the selected duration.
Viewing the Power Statistics in a Chart
This option is available only on some Cisco UCS C-Series servers.
Before you begin
• You must enabled power capping.
• You must log in with admin privileges to perform this task.
Procedure
Step 1
Step 2
Step 3
Step 4
In the Navigation pane, click the Chassis menu.
In the Chassis menu, click Power Management .
In the work pane, click the Power Monitoring tab.
On the Power Monitoring tab, review and update the chart, component, to view the power consumption details.
Name
Chart drop-down list
Description
Allows you to collect the trends of power consumption from every server for the selected duration. This can be one of the following:
• Last One Hour — Plots the chart for every five minutes
• Last One Day —Plots the chart for every hour from the current time.
• Last One Week —Plots the chart for each day.
50
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Managing the Server
Downloading Power Statistics and Server Utilization Data
Step 5
Name
Component drop-down list
Maximum
Minimum
Average
Current
Plot button check box check box check box check box
If checked, the plot displays the maximum number of watts consumed by the selected component for the selected duration.
If checked, the plot displays the minimum number of watts consumed by the selected component for the selected duration.
If checked, the plot displays the average amount of power consumed by the selected component for the selected duration.
If checked, the chart displays the current power consumed by the selected component for the selected duration.
Displays the power consumed by the selected component for the specified duration.
The power reading chart plots power consumption values of different components for the selected duration.
These power consumption values are captured from the time that the host is powered on. When a power profile is enabled, the power limit is plotted in the chart as a red line. This plot can be used to determine the power consumption trend of the system. To view the configured power limit values of a particular domain, move the mouse over these trend lines.
If choose the Standard profile, the trend line represent the power limit. If you choose the Advance profile, it represents the power limit for CPU, memory, and platform depending on your power profile configuration.
Note These trend lines are not displayed if the profile is disabled on the Power Cap Configuration tab.
Click Save Changes .
Description
The component for which you want to view the power consumption over the selected duration. This can be one of the following:
• Platform
• CPU
• Memory
• All
Downloading Power Statistics and Server Utilization Data
This option is available only on some Cisco UCS C-Series servers.
Before you begin
You must log in with admin privileges to perform this task.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
51
Managing the Server
Configuring the Power Restore Policy
Procedure
Step 1
Step 2
Step 3
Step 4
In the Navigation pane, click the Chassis menu.
In the Chassis menu, click Power Management .
In the Work pane, click the Power Monitoring tab.
In the Power Monitoring tab, click Download Power Statistics and Server Utilization Data
The files are downloaded to your local download folder.
Note If the file size of the already downloaded statistics file is less than 256 KB, then when you download, another set of files is downloaded, one for the power statistics and the other for host server utilization.
If the size of the existing files exceeds 256 KB, then the next set of files overwrites the existing ones.
Configuring the Power Restore Policy
The power restore policy determines how power is restored to the server after a chassis power loss.
Before you begin
You must log in with admin privileges to perform this task.
Procedure
Step 1
Step 2
Step 3
In the Navigation pane, click the Compute menu.
In the work pane, click the Power Policies tab.
In the Power Restore Policy area, update the following fields:
Name Description
Power Restore Policy drop-down list
The action to be taken when chassis power is restored after an unexpected power loss. This can be one of the following:
• Power Off —The server remains off until it is manually restarted.
• Power On —The server is allowed to boot up normally when power is restored. The server can restart immediately or, optionally, after a fixed or random delay.
• Restore Last State —The server restarts and the system attempts to restore any processes that were running before power was lost.
Step 4 Click Save Changes .
52
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Managing the Server
Configuring Fan Policies
Configuring Fan Policies
Fan Control Policies
Fan Control Policies enable you to control the fan speed to bring down server power consumption and noise levels. Prior to these fan policies, the fan speed increased automatically when the temperature of any server component exceeded the set threshold. To ensure that the fan speeds were low, the threshold temperatures of components are usually set to high values. While this behavior suited most server configurations, it did not address the following situations:
• Maximum CPU performance
For high performance, certain CPUs must be cooled substantially below the set threshold temperature.
This required very high fan speeds which resulted in higher power consumption and increased noise levels.
• Low power consumption
To ensure the lowest power consumption, fans must run very slowly, and in some cases, stop completely on servers that support it. But slow fan speeds resulted in servers overheating. To avoid this situation, it is necessary to run fans at a speed that is moderately faster than the lowest possible speed.
With the introduction of fan policies, you can determine the right fan speed for the server, based on the components in the server. In addition, it allows you to configure the fan speed to address problems related to maximum CPU performance and low power consumption.
Following are the fan policies that you can choose from:
• Balanced —This setting can cool almost any server configuration, but may not be suitable for servers with PCIe cards as these cards overheat easily.
• Low Power —This setting is ideal for minimal configuration servers that do not contain any PCIe cards.
• High Power —This policy is ideal for servers that contain PCIe cards that overheat easily and have high temperatures.
• Maximum Power —This setting can be used for server configurations that required extremely high fan speeds. This policy is ideal for servers that contain PCIe cards that overheat easily and have very high temperatures.
• Acoustic —This setting can be used for configuring the fan noise level, thereby enabling noise reduction in the servers.
Application of this policy might result in performance throttling impacting system performance. If excessive thermal or performance events are recorded in the event logs, select a standard fan control policy like Low Power , which is a non-disruptive change.
Note This option is available only on Cisco UCS C220 M5, C240 SD M5, C240 M5 servers. For these servers, Acoustic is the default fan policy.
For other servers, default fan policy depends on the server configuration and the number of PCIe cards present in the server.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
53
Managing the Server
Configuring the Fan Policy
Note For Cisco UCS M5 servers, although you set a fan policy in Cisco IMC, the actual speed that the fan runs at is determined by the configuration requirements of the server. PCIe cards are tagged with minimum fan speed depending on thermal requirements. If the server is equipped with these PCIe cards, you cannot configure the fan policy, which go below the tagged requirement.
The Configuration Status displays the status of the configured fan policy in Cisco UCS M5 servers. This can be one of the following:
• SUCCESS —The selected fan policy matches the actual fan speed that runs on the server.
• PENDING —The configured fan policy is not in effect yet. This can be due to one of the following:
• The server is powered off
• The BIOS POST is not complete
• FAN POLICY OVERRIDE—Overrides the specified fan speed with the actual speed determined by the configuration requirements of the server.
Configuring the Fan Policy
You can determine the right fan policy based on the server configuration and server components.
Before you begin
You must log in with admin privileges to perform this task.
Procedure
Step 1
Step 2
Step 3
In the Navigation pane, click the Compute menu.
In the work pane, click the Power Policies tab.
In the Configured Fan Policy area, select a fan policy from the drop-down list. It can be one of the following:
54
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Managing the Server
Name
Fan Policy drop-down list
Applied Fan Policy field
Configuring the Fan Policy
Description
This can be one of the following:
• Balanced —This setting can cool almost any server configuration, but may not be suitable for servers with PCIe cards as these cards overheat easily.
• Low Power —This setting is ideal for minimal configuration servers that do not contain any
PCIe cards.
• High Power —This policy is ideal for servers that contain PCIe cards that overheat easily and have high temperatures.
• Maximum Power —This setting can be used for server configurations that required extremely high fan speeds. This policy is ideal for servers that contain PCIe cards that overheat easily and have very high temperatures.
• Acoustic —This setting can be used for configuring the fan noise level, thereby enabling noise reduction in the servers.
Application of this policy might result in performance throttling impacting system performance. If excessive thermal or performance events are recorded in the event logs, select a standard fan control policy like
Low Power , which is a non-disruptive change.
Note This option is available only on Cisco
UCS C220 M5, C240 SD M5, C240
M5 servers. For these servers,
Acoustic is the default fan policy.
For other servers, default fan policy depends on the server configuration and the number of PCIe cards present in the server.
The actual speed of the fan that runs on the server.
When the configured fan policy is not in effect, it displays N/A. The configured fan policy takes effect when the server is powered on and the POST is complete.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
55
Managing the Server
Configuring DIMM Blacklisting
Name
Configuration Status field
Description
The configuration status of the fan policy. This can be one of the following:
• SUCCESS —The fan speed set by you matches the actual fan speed that runs on the server.
• PENDING —The configured fan policy is not in effect yet. This can be due to one of the following:
• The server is powered off
• The BIOS POST is not complete
• FAN POLICY OVERRIDE—Overrides the specified fan speed with the actual speed determined by the configuration requirements of the server.
Step 4 Click Save Changes .
Configuring DIMM Blacklisting
DIMM Black Listing
In Cisco IMC, the state of the Dual In-line Memory Module (DIMM) is based on SEL event records. A DIMM is marked bad if the BIOS encounters a non-correctable memory error or correctable memory error with 16000 error counts during memory test execution during BIOS post. If a DIMM is marked bad, it is considered a non-functional device.
If you enable DIMM blacklisting, Cisco IMC monitors the memory test execution messages and blacklists any DIMM that encounters memory errors at any given point of time in the DIMM SPD data. This allows the host to map out those DIMMs.
DIMMs are mapped out or blacklisted only when Uncorrectable errors occur. When a DIMM gets blacklisted, other DIMMs in the same channel are ignored or disabled, which means that the DIMM is no longer considered bad.
Note DIMMs do not get mapped out or blacklisted for 16000 Correctable errors.
56
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Managing the Server
Enabling DIMM Black Listing
Enabling DIMM Black Listing
Before you begin
• You must be logged in as an administrator.
Procedure
Step 1
Step 2
Step 3
Step 4
In the Navigation pane, click the Chassis menu.
In the Chassis menu, click Inventory .
In the Inventory pane, click the Memory tab.
In the Memory pane's DIMM Black Listing area, click the Enable DIMM Black List check box.
Configuring BIOS Settings
Configuring BIOS Settings
Before you begin
You must log in with admin privileges to perform this task.
Procedure
Step 1
Step 2
Step 3
Step 4
In the Navigation pane, click the Compute menu.
In the Compute menu, click the BIOS tab.
In the BIOS tab, click the Configure BIOS tab.
Refer
BIOS Parameters by Server Model, on page 353
to update the following tabs:
• I/O
• Server Management
• Security
• Processor
• Memory
• Power/Performance
Note The BIOS parameters available depend on the model of the server that you are using.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
57
Managing the Server
Entering BIOS Setup
Important A BIOS parameter available in one tab may affect the parameters on all available tabs, not just the parameters on the tab that you are viewing.
Entering BIOS Setup
Before you begin
• The server must be powered on.
• You must log in with admin privileges to perform this task.
Procedure
Step 1
Step 2
Step 3
Step 4
In the Navigation pane, click the Compute menu.
In the work pane, click the BIOS tab.
In the Actions area, click Enter BIOS Setup .
Click OK at the prompt.
Enables enter BIOS setup. On restart, the server enters the BIOS setup.
Clearing the BIOS CMOS
Before you begin
• The server must be powered on.
• You must log in with admin privileges to perform this task.
Procedure
Step 1
Step 2
Step 3
Step 4
In the Navigation pane, click the Compute menu.
In the work pane, click the BIOS tab.
In the Actions area, click Clear BIOS CMOS .
Click OK to confirm.
Clears the BIOS CMOS.
58
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Managing the Server
Restoring BIOS Manufacturing Custom Settings
Restoring BIOS Manufacturing Custom Settings
Before you begin
• The server must be powered on.
• You must log in with admin privileges to perform this task.
Procedure
Step 1
Step 2
Step 3
Step 4
Step 5
Step 6
In the Navigation pane, click the Compute menu.
In the Compute menu, select a server.
In the work pane, click the BIOS tab.
In the Actions area, click Restore Manufacturing Custom Settings .
Click Yes if you wish to reboot the server immediately.
Click OK to confirm.
Restoring BIOS Defaults
Before you begin
• The server must be powered on.
• You must log in with admin privileges to perform this task.
Procedure
Step 1
Step 2
Step 3
Step 4
Step 5
Step 6
In the Navigation pane, click the Compute menu.
In the Compute menu, select a server.
In the work pane, click the BIOS tab.
In the Actions area, click Restore Defaults .
Click Yes if you wish to reboot the server immediately.
Click OK to confirm.
BIOS Profiles
On the Cisco UCS server, default token files are available for every S3260 server platform, and you can configure the value of these tokens using the Graphic User Interface (GUI), CLI interface, and the XML API interface. To optimize server performance, these token values must be configured in a specific combination.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
59
Managing the Server
Uploading a BIOS Profile
Configuring a BIOS profile helps you to utilize pre-configured token files with the right combination of the token values. Some of the pre-configured profiles that are available are virtualization, high-performance, low power, and so on. You can download the various options of these pre-configured token files from the Cisco website and apply it on the servers through the BMC.
You can edit the downloaded profile to change the value of the tokens or add new tokens. This allows you to customize the profile to your requirements without having to wait for turnaround time.
Uploading a BIOS Profile
You can upload a BIOS profile either from a remote server location or through a browser client.
Before you begin
You must log in with admin privileges to perform this task.
Procedure
Step 1
Step 2
Step 3
Step 4
Step 5
In the Navigation pane, click the Compute menu.
In the work pane, click the BIOS tab.
Click the Configure BIOS Profile tab.
To upload the BIOS profile using a remote server location, in the BIOS Profile area, click the Upload button.
In the Upload BIOS Profile dialog box, update the following fields:
Name Description
Upload BIOS Profile from drop-down list The remote server type. This can be one of the following:
• TFTP
• FTP
• SFTP
• SCP
• HTTP
Server IP/Hostname field
Path and Filename
Username
Password field field field
The IP address or hostname of the server on which the BIOS profile information is available. Depending on the setting in the Upload BIOS Profile from drop-down list, the name of the field may vary.
The path and filename of the BIOS profile on the remote server.
Username of the remote server.
Password of the remote server.
60
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Managing the Server
Activating a BIOS Profile
Step 6
Step 7
Name
Upload
Cancel button button
Description
Uploads the selected BIOS profile.
Note If you chose SCP or SFTP as the remote server type while performing this action, a pop-up window is displayed with the message Server (RSA) key fingerprint is
<server_finger_print _ID> Do you wish to continue?
. Click Yes or No depending on the authenticity of the server fingerprint.
The fingerprint is based on the host's public key and helps you to identify or verify the host you are connecting to.
Closes the wizard without making any changes to the firmware versions stored on the server.
To upload the BIOS profile using a browser client, in the BIOS Profile area, click the Upload button.
In the Upload BIOS Profile dialog box, update the following fields:
Name
File field
Description
The BIOS profile that you want to upload.
Browse button Opens a dialog box that allows you to navigate to the appropriate file.
What to do next
Activate a BIOS profile.
Activating a BIOS Profile
Before you begin
You must log in with admin privileges to perform this task.
Procedure
Step 1
Step 2
Step 3
Step 4
Step 5
In the Navigation pane, click the Compute menu.
In the work pane, click the BIOS tab.
Click the Configure BIOS Profile tab.
Select a BIOS profile from the BIOS Profile area and click Activate .
At the prompt, click Yes to activate the BIOS profile.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
61
Deleting a BIOS Profile
Deleting a BIOS Profile
Before you begin
You must log in with admin privileges to perform this task.
Procedure
Step 1
Step 2
Step 3
Step 4
Step 5
In the Navigation pane, click the Compute menu.
In the Compute menu, select a server.
In the work pane, click the BIOS tab.
Select a BIOS profile from the BIOS Profile area and click Delete .
At the prompt, click OK to delete the BIOS profile.
Backing up a BIOS Profile
Before you begin
You must log in with admin privileges to perform this task.
Procedure
Step 1
Step 2
Step 3
Step 4
Step 5
In the Navigation pane, click the Compute menu.
In the Compute menu, select a server.
In the work pane, click the BIOS tab.
Select a BIOS profile from the BIOS Profile area and click Take Backup .
At the prompt, click OK to take a backup of the BIOS profile.
What to do next
Activate a BIOS profile.
Viewing BIOS Profile Details
Before you begin
You must log in with admin privileges to perform this task.
Procedure
Step 1 In the Navigation pane, click the Compute menu.
62
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Managing the Server
Managing the Server
Setting Dynamic Front Panel Temperature Threshold
Step 2
Step 3
Step 4
Step 5
In the Compute menu, select a server.
In the work pane, click the BIOS tab.
Select a BIOS profile from the BIOS Profile area and click Details .
Review the following information in the BIOS Profile Details window:
Name
Token Name column
Description
Displays the token name of the BIOS profile.
Displays the user name of the BIOS profile.
Display Name column
Profile Value column
Actual Value column
Displays the value that was provided in the uploaded file.
Displays the value of the active BIOS configuration.
Setting Dynamic Front Panel Temperature Threshold
The Dynamic Front Panel Temperature Threshold option allows you to set the upper critical threshold for the front panel temperature sensor.
Procedure
Step 1
Step 2
Step 3
Step 4
Step 5
In the Navigation pane, click the Chassis menu.
In the Chassis menu, click Sensors .
In the Sensors pane, click the Temperature tab.
Expand the Dynamic Front Panel Temperature Threshold area, and enter an upper critical threshold for the front panel temperature sensor in the Critical field. You can enter a value between 8 and 50.
Click Save Changes .
Persistent Memory Modules
Cisco UCS C-Series Release 4.0(4) introduces support for the Intel
®
Optane
™
Data Center persistent memory modules on the UCS M5 servers that are based on the Second Generation Intel
®
Xeon
These persistent memory modules can be used only with the Second Generation Intel
®
®
Scalable processors.
Xeon
®
Scalable processors.
Persistent memory modules are non-volatile memory modules that bring together the low latency of memory and the persistence of storage. Data stored in persistent memory modules can be accessed quickly compared to other storage devices, and is retained across power cycles.
For detailed information about configuring persistent memory modules, see the Cisco UCS: Configuring and
Managing Intel ® Optane ™ Data Center Persistent Memory Modules Guide.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
63
Persistent Memory Modules
Managing the Server
64
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Viewing Server Properties
C H A P T E R
5
This chapter includes the following sections:
•
Viewing Server Utilization, on page 65
•
Viewing CPU Properties, on page 67
•
Viewing Memory Properties, on page 67
•
Viewing PCI Adapter Properties, on page 70
•
Viewing Storage Properties, on page 71
•
Viewing TPM Properties, on page 71
•
Viewing a PID Catalog , on page 73
Viewing Server Utilization
Procedure
Step 1
Step 2
In the Navigation pane, click the Chassis menu.
In the Chassis menu, click Summary .
The Summary node provides information on Chassis Properties , Chassis status , Cisco IMC Information ,
Power Utilization and Server Utilization .
Real-time monitoring of CPU, memory, and I/O utilization in the system is provided interms of Compute
Usage Per Second (CUPS) . It is independent of the OS and does not consume CPU resources.
Cisco servers monitors below sensors:
Platform CUPS Sensor - Provides the Computation, Memory, and I/O resource utilization value in the form of a platform CUPS Index.
Core CUPS Sensor - Provides the computation utilization value.
Memory CUPS Sensor - Provides the memory utilization value.
IO CUPS Sensor - Provides the I/O resource utilization value.
Note CUPS sensors are hardware level sensors and the values will not match the values from OS based tools.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
65
Viewing Server Properties
Viewing Server Utilization
Step 3
These utilization values are obtained by querying the data from a set of dedicated, sideband telemetry counters provided by the platform ingredients (CPU and chipset). These counters are called Resource Monitoring
Counters (RMCs) .
RMCs provide the real-time information pertaining to the three main domains of platform resources – CPU, memory, and I/O. The utilization information for each of these domains is obtained by aggregating the individual counters at a resource instance level.
In the Server Utilization area, review the following information:
Name Description
Overall Utilization (%)
CPU Utilization (%)
Measured as CUPS Index. This is a composite metric used to provide quick high level assessment of
Platform Utilization. The CUPS Index is thus a measure of the compute headroom available on the server. Hence, if the system has a large CUPS Index, then there is limited headroom to place additional workload on that system. As the resource consumption decreases, the system’s CUPS Index decreases. A low
CUPS Index indicates that there is a large amount of compute headroom and the server is a prime target for receiving new workloads or having the workload migrated off and the server being put into a lower power state in order to reduce power consumption.
Such workload monitoring can then be applied throughout the data center to provide a high-level and holistic view of the datacenter’s workload.
CPU RMC provides CPU utilization metrics. These are individual CPU core counters which are aggregated to provide the cumulative utilization of all the cores in the package.
Memory Utilization (%)
IO Utilization (%)
Memory RMC provides memory utilization metrics.
These are individual counters to measure memory traffic occurring at each memory channel or memory controller instance. These are then aggregated to measure the cumulative memory traffic across all the memory channels in the package.
IO RMC provides IO utilization metrics. These are individual counters, one per root port in the PCI
Express Root Complex to measure PCI Express traffic emanating from or directed to that root port and the segment below. These counters are then aggregated to measure PCI express traffic for all PCI Express segments emanating from the package. The PCI
Express Root Port represents a PCI segment and is hence is the single central component that carries the entire traffic generated by that segment.
66
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Viewing Server Properties
Viewing CPU Properties
Viewing CPU Properties
Procedure
Step 1
Step 2
Step 3
Step 4
In the Navigation pane, click the Chassis menu.
In the Chassis menu, click Inventory .
In the Inventory pane, click the CPUs tab.
Review the following information for each CPU:
Name
Socket Name field
Description
The socket in which the CPU is installed.
Vendor
Status
Family
Version field field field field
Speed field
Number of Cores field
Signature field
Number of Threads field
The vendor for the CPU.
The status of the CPU.
The family to which this CPU belongs.
The version information of the CPU.
The CPU speed, in megahertz.
The number of cores in the CPU.
The signature information for the CPU.
The maximum number of threads that the CPU can process concurrently.
Viewing Memory Properties
Procedure
Step 1
Step 2
Step 3
Step 4
In the Navigation pane, click the Chassis menu.
In the Chassis menu, click Inventory .
In the Inventory pane, click the Memory tab.
In the Memory Summary area, review the following summary information about memory:
Name
Memory Speed field
Description
The memory speed, in megahertz.
Total Memory field The total amount of memory available on the server if all DIMMs are fully functional.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
67
Viewing Server Properties
Viewing Memory Properties
Step 5
Name
Effective Memory field
Description
The actual amount of memory currently available to the server.
When a server has Intel
®
Optane
™
DC persistent memory modules the effective memory is calculated as follows:
• Memory mode or Mixed mode —It is an approximate sum of all the DCPMM memory.
Note Memory and Mixed modes are available only on some servers.
• Appdirect mode —It is an approximate sum of all the DCPMM memory and the DRAMs memory.
Redundant Memory field The amount of memory used for redundant storage.
Failed Memory field
Ignored Memory field
The amount of memory that is currently failing, in megabytes.
The amount of memory currently not available for use, in megabytes.
Number of Ignored DIMMs field The number of DIMMs that the server cannot access.
Number of Failed DIMMs field The number of DIMMs that have failed and cannot be used.
Memory RAS Possible field
Memory Configuration field
Details about the RAS memory configuration that the server supports.
The current memory configuration. This can be one of the following:
• Maximum Performance —The system automatically optimizes the memory performance.
• Mirroring —The server maintains two identical copies of the data in memory. This option effectively halves the available memory on the server, as one half is automatically reserved for mirrored copy.
• Lockstep —If the DIMM pairs in the server have an identical type, size, and organization and are populated across the SMI channels, you can enable lockstep mode to minimize memory access latency and provide better performance.
DIMM location diagram Displays the DIMM or memory layout for the current server.
In the DIMM Black Listing area, view the overall status of a DIMM and also enable DIMM black listing.
Name
Overall DIMM Status field
Description
The overall status of a DIMM. This can be one of the following:
• Good —The DIMM status is available.
• Severe Fault — The DIMM status when uncorrectable ECC errors are present.
68
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Viewing Server Properties
Viewing Memory Properties
Step 6
Name
Enable DIMM Black List checkbox
Description
Check this option to enable DIMM black listing.
In the Memory Details table, review the following detailed information about each DIMM:
Tip Click a column header to sort the table rows, according to the entries in that column.
Name
Name column
Capacity column
Channel Speed column
Channel Type column
Memory Type Detail column
Bank Locator column
Manufacturer column
Serial Number
Asset Tag
Visibility column
Part Number column
Operability
Data Width column column column column
Description
The name of the DIMM slot in which the memory module is installed.
The size of the DIMM.
The clock speed of the memory channel, in megahertz.
The type of memory channel.
The type of memory used in the device.
The location of the DIMM within the memory bank.
The vendor ID of the manufacturer. This can be one of the following:
• 0x2C00 —Micron Technology, Inc.
• 0x5105 —Qimonda AG i. In.
• 0x802C —Micron Technology, Inc.
• 0x80AD —Hynix Semiconductor Inc.
• 0x80CE —Samsung Electronics, Inc.
• 0x8551 —Qimonda AG i. In.
• 0xAD00 —Hynix Semiconductor Inc.
• 0xCE00 —Samsung Electronics, Inc.
The serial number of the DIMM.
The asset tag associated with the DIMM, if any.
The part number for the DIMM assigned by the vendor.
Whether the DIMM is available to the server.
Whether the DIMM is currently operating correctly.
The amount of data the DIMM supports, in bits.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
69
Viewing Server Properties
Viewing PCI Adapter Properties
Viewing PCI Adapter Properties
Before you begin
The server must be powered on, or the properties will not display.
Procedure
Step 1
Step 2
Step 3
Step 4
In the Navigation pane, click the Chassis menu.
In the Chassis menu, click Inventory .
In the Inventory pane, click the PCI Adapters tab.
In the PCI Adapters area, review the following information for the installed PCI adapters:
Name
Slot ID column
Description
The slot in which the adapter resides.
The name of the adapter.
Product Name column
Option ROM Status column Indicates the Option ROM status. This can be one of the following:
• Loaded—Data is available in the card.
• Unloaded—Data is not available in the card.
• Load Error—Card is present and Option ROM is enabled. But
Option ROM failed to load due to an error in the card.
Firmware Version column The firmware versions of the adapters.
Note The firmware versions are displayed only for adapters that provide versions through the standard UEFI interface. For example, Intel LOM and Emulex Adapters.
Vendor ID column
Sub Vendor ID column
Device ID column
Sub Device ID column
The adapter ID assigned by the vendor.
The secondary adapter ID assigned by the vendor.
The device ID assigned by the vendor.
The secondary device ID assigned by the vendor.
70
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Viewing Server Properties
Viewing Storage Properties
Viewing Storage Properties
Before you begin
The server must be powered on, or the properties will not display.
Procedure
Step 1
Step 2
Step 3
Step 4
In the Navigation pane, click the Compute menu.
In the Compute menu, select a server.
In the work pane, click the Inventory tab.
In the Storage tab, review the following information:
Name
Controller field
Description
PCIe slot in which the controller drive is located.
PCI Slot field
Product Name field
The name of the PCIe slot in which the controller drive is located.
Name of the controller.
Serial Number field
Firmware Package Build field
Product ID field
Battery Status field
Cache Memory Size field
Health field
The serial number of the storage controller.
The active firmware package version number.
Product ID of the controller.
Status of the battery.
The size of the cache memory, in megabytes.
The health of the controller.
Viewing TPM Properties
Procedure
Step 1
Step 2
Step 3
Step 4
In the Navigation pane, click the Chassis menu.
In the Chassis menu, click Inventory .
In the Inventory pane, click the TPM tab
Review the following information:
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
71
Viewing Server Properties
Viewing TPM Properties
Name
Version
Presence
Model field field field
Enabled Status
Vendor
Active Status
Serial field field
Ownership field field field
Revision field
Firmware Version field
Description
The TPM version. This field displays NA if the TPM version details are not available.
Presence of the TPM module on the host server.
• Equipped —The TPM is present on the host server.
• Empty —The TPM does not exist on the host server.
The model number of the TPM. This field displays NA if the TPM does not exist on the host server.
Whether or not the TPM is enabled.
• Enabled —The TPM is enabled.
• Disabled —The TPM is disabled.
• Unknown —The TPM does not exist on the host server.
The name of the TPM vendor. This field displays NA if the TPM does not exist on the host server.
Activation status of the TPM.
• Activated —The TPM is activated.
• Deactivated —The TPM is deactivated.
• Unknown —The TPM does not exist on the host server.
Note In some C-series servers that have installed TPM version 2.0,
Active Status is displayed as NA .
The serial number of the TPM. This field displays NA if the TPM does not exist on the host server.
The ownership status of TPM.
• Owned —The TPM is owned.
• Unowned —The TPM is unowned.
• Unknown —The TPM does not exist on the host server.
Note In some C-series servers that have installed TPM version 2.0,
Ownership status is displayed as NA .
Revision number of the TPM. This field displays NA if the TPM does not exist on the host server.
Details of the firmware version.
72
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Viewing Server Properties
Viewing a PID Catalog
Viewing a PID Catalog
Procedure
Step 1
Step 2
Step 3
Step 4
Step 5
Step 6
In the Navigation pane, click the Compute tab.
In the Compute working area, click the PID Catalog tab.
Review the following summary information about the PID catalog:
• Activation Status : The activation status of the PID catalog.
• Current Activated Version : The activated version of the PID catalog.
In the CPUs table, review the following information about CPU:
Name
Socket Name column
Description
The socket in which the CPU is installed.
Product ID
Model column column
The product ID for the CPU.
The model number of the CPU
In the Memory table, review the following information about memory:
Name
Name column
Description
The name of the memory slot.
The product ID for the memory slot assigned by the vendor.
Product ID column
Vendor ID column
Capacity column
Speed (MHz) column
The ID assigned by the vendor.
The size of the memory.
The memory speed, in megahertz.
In the PCI Adapters table, review the following information about PCI adapter:
Name
Slot column
Description
The slot in which the adapter resides.
Product ID
Vendor ID
Device ID column column
Sub Vendor ID
Sub Device ID column column column
The product ID for the adapter.
The adapter ID assigned by the vendor.
The secondary adapter ID assigned by the vendor.
The device ID assigned by the vendor.
The secondary device ID assigned by the vendor.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
73
Viewing Server Properties
Viewing a PID Catalog
Step 7 In the HDD table, review the following information about HDD:
Name
Disk column
Description
The disk of the hard drive.
Product ID column
Controller column
The product ID for the hard drive.
The system-defined name of the selected Cisco Flexible Flash controller.
This name cannot be changed.
Vendor column
Model column
The vendor for the hard drive.
The model of the hard drive.
74
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
C H A P T E R
6
Viewing Sensors
This chapter includes the following sections:
•
Viewing Chassis Sensors, on page 75
Viewing Chassis Sensors
Viewing Power Supply Sensors
Procedure
Step 1
Step 2
Step 3
Step 4
In the Navigation pane, click the Chassis menu.
In the Chassis menu, click Sensors .
In the Sensors working area, click the Power Supply tab.
Review the following sensor properties for power supply:
Properties Area
Name
Redundancy Status field
Description
The power supply redundancy status.
Threshold Sensors Area
Name
Sensor Name column
Description
The name of the sensor
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
75
Viewing Sensors
Viewing Fan Sensors
Name
Sensor Status column
Description
The status of the sensor. This can be one of the following:
• Unknown
• Informational
• Normal
• Warning
• Critical
• Non-Recoverable
Reading column
Critical Threshold Min column
The current power usage, in watts.
The minimum critical threshold.
Critical Threshold Max column The maximum critical threshold.
Discrete Sensors Area
Name
Sensor Name column
Sensor Status column
Description
The name of the sensor.
The status of the sensor. This can be one of the following:
• Unknown
• Informational
• Normal
• Warning
• Critical
• Non-Recoverable
Reading column The basic state of the sensor.
Viewing Fan Sensors
Procedure
Step 1
Step 2
Step 3
In the Navigation pane, click the Chassis menu.
In the Chassis menu, click Sensors .
In the Sensors working area, click the Fan tab.
76
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Viewing Sensors
Viewing Temperature Sensors
Step 4 Review the following fan sensor properties:
Name
Sensor Name column
Description
The name of the sensor
Sensor Status column The status of the sensor. This can be one of the following:
• Unknown
• Informational
• Normal
• Warning
• Critical
• Non-Recoverable
Speed (RPMS) column
Critical Threshold Min column
The fan speed in RPM.
The minimum critical threshold.
Critical Threshold Max column The maximum critical threshold.
Non-Recoverable Threshold Min column
The minimum non-recoverable threshold.
Non-Recoverable Threshold Max column
The maximum non-recoverable threshold.
Viewing Temperature Sensors
Procedure
Step 1
Step 2
Step 3
Step 4
In the Navigation pane, click the Chassis menu.
In the Chassis menu, click Sensors .
In the Sensors working area, click the Temperature tab.
Review the following temperature sensor properties:
Name
Sensor Name column
Description
The name of the sensor
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
77
Viewing Sensors
Viewing Voltage Sensors
Name
Sensor Status column
Description
The status of the sensor. This can be one of the following:
• Unknown
• Informational
• Normal
• Warning
• Critical
• Non-Recoverable
Temperature column
Critical Threshold Min column
The current temperature, in Celsius.
The minimum critical threshold.
Critical Threshold Max column The maximum critical threshold.
Non-Recoverable Threshold Min column
The minimum non-recoverable threshold.
Non-Recoverable Threshold Max column
The maximum non-recoverable threshold.
Viewing Voltage Sensors
Procedure
Step 1
Step 2
Step 3
Step 4
In the Navigation pane, click the Chassis menu.
In the Chassis menu, click Sensors .
In the Sensors working area, click the Voltage tab.
Review the following voltage sensor properties:
Name
Sensor Name column
Description
The name of the sensor
78
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Viewing Sensors
Viewing Current Sensors
Name
Sensor Status column
Description
The status of the sensor. This can be one of the following:
• Unknown
• Informational
• Normal
• Warning
• Critical
• Non-Recoverable
Voltage (V) column
Critical Threshold Min column
The current voltage, in Volts.
The minimum critical threshold.
Critical Threshold Max column The maximum critical threshold.
Non-Recoverable Threshold Min column
The minimum non-recoverable threshold.
Non-Recoverable Threshold Max column
The maximum non-recoverable threshold.
Viewing Current Sensors
Procedure
Step 1
Step 2
Step 3
Step 4
In the Navigation pane, click the Chassis menu.
In the Chassis menu, click Sensors .
In the Sensors working area, click the Current tab.
Review the following current sensor properties:
Name
Sensor Name column
Description
The name of the sensor
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
79
Viewing Sensors
Viewing LED Sensors
Name
Sensor Status column
Description
The status of the sensor. This can be one of the following:
• Unknown
• Informational
• Normal
• Warning
• Critical
• Non-Recoverable
Current (A) column
Critical Threshold Min column
The value of current, in Ampere (A).
The minimum critical threshold.
Critical Threshold Max column The maximum critical threshold.
Non-Recoverable Threshold Min column
The minimum non-recoverable threshold.
Non-Recoverable Threshold Max column
The maximum non-recoverable threshold.
Viewing LED Sensors
Procedure
Step 1
Step 2
Step 3
Step 4
In the Navigation pane, click the Chassis menu.
In the Chassis menu, click Sensors .
In the Sensors working area, click the LEDs tab.
Review the following LED sensor properties:
Name
Sensor Name column
Description
The name of the sensor
LED Status column
LED Color column
Whether the LED is on, blinking, or off.
The current color of the LED.
For details about what the colors mean, see the hardware installation guide for the type of server you are using.
80
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Viewing Sensors
Viewing Storage Sensors
Viewing Storage Sensors
Procedure
Step 1
Step 2
Step 3
Step 4
In the Navigation pane, click the Compute menu.
In the Compute menu, select a server.
In the work pane, click Sensors tab.
Under the Storage tab, view the following statistics for the server in Storage Sensors area:
Name
Name column
Description
The name of the storage device.
Status column A brief description of the storage device status.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
81
Viewing Storage Sensors
Viewing Sensors
82
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
C H A P T E R
7
Managing Remote Presence
This chapter includes the following sections:
•
Configuring Serial Over LAN, on page 83
•
Configuring Virtual Media, on page 85
•
Virtual KVM Console, on page 92
•
Launching KVM Console, on page 92
•
Virtual KVM Console , on page 93
•
Configuring the Virtual KVM, on page 97
Configuring Serial Over LAN
Serial over LAN enables the input and output of the serial port of a managed system to be redirected over IP.
Configure and use serial over LAN on your server when you want to reach the host console with Cisco IMC.
Important You cannot use native serial redirection and serial over LAN simultaneously.
Before you begin
You must log in as a user with admin privileges to configure serial over LAN.
Procedure
Step 1
Step 2
Step 3
Step 4
Step 5
In the Navigation pane, click the Compute menu.
In the Compute menu, select a server.
In the work pane, click the Remote Management tab.
In the Remote Presence pane, click the Serial over LAN tab.
In the Serial over LAN Properties area, update the following properties:
Name
Enabled check box
Description
If checked, Serial over LAN (SoL) is enabled on this server.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
83
Managing Remote Presence
Configuring Serial Over LAN
Name
Baud Rate drop-down list
Com Port
SSH Port drop-down list filed
Description
The baud rate the system uses for SoL communication. This can be one of the following:
• 9600 bps
• 19.2 kbps
• 38.4 kbps
• 57.6 kbps
• 115.2 kbps
The serial port through which the system routes SoL communication.
You can select one of the following:
• com0 —SoL communication is routed through COM port 0, an externally accessible serial port that supports either a physical RJ45 connection to an external device or a virtual SoL connection to a network device.
If you select this option, the system enables SoL and disables the
RJ45 connection, which means that the server can no longer support an external serial device.
• com1 —SoL communication is routed through COM port 1, an internal port accessible only through SoL.
If you select this option, you can use SoL on COM port 1 and the physical RJ45 connection on COM port 0.
Note Changing the Com Port setting disconnects any existing SoL sessions.
The port through which you can access Serial over LAN directly. The port enables you to by-pass the Cisco IMC shell to provide direct access to SoL.
The valid range is 1024 to 65535. The default value is 2400.
Note Changing the SSH Port setting disconnects any existing SSH sessions.
Step 6 Click Save Changes .
84
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Managing Remote Presence
Configuring Virtual Media
Configuring Virtual Media
Before you begin
You must log in as a user with admin privileges to configure virtual media.
Procedure
Step 1
Step 2
Step 3
Step 4
Step 5
Step 6
In the Navigation pane, click Compute .
In the Compute menu, select a server.
Click the Remote Management tab.
In the Remote Management tab, click the Virtual Media tab.
In the vKVM Console Based vMedia Properties Area , update the following properties:
Name
Enabled check box
Description
If checked, virtual media is enabled.
Note If you clear this check box, all virtual media devices are automatically detached from the host.
Active Sessions field The number of virtual media sessions that are currently running.
Enable Virtual Media Encryption check box
If checked, all virtual media communications are encrypted.
Low Power USB Enabled check box
If checked, low power USB is enabled.
If the low power USB is enabled, after mapping the ISO and rebooting the host, the virtual drives appear on the boot selection menu.
But, while mapping an ISO to a server that has a UCS VIC P81E card and the NIC is in Cisco Card mode, this option must be disabled for the virtual drives to appear on the boot selection menu.
Click Save Changes .
Creating a Cisco IMC Mapped vMedia Volume
Before you begin
You must log in with admin privileges to perform this task.
Procedure
Step 1 In the Navigation pane, click the Compute menu.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
85
Managing Remote Presence
Creating a Cisco IMC Mapped vMedia Volume
Step 2
Step 3
Step 4
Step 5
Step 6
In the Compute menu, select a server.
In the work pane, click the Remote Management tab.
In the Remote Management tab, click the Virtual Media tab
In the Current Mappings area, click Add New Mapping .
In the Add New Mapping dialog box, update the following fields:
Name
Volume field
Mount Type drop-down list
Description
The identity of the image mounted for mapping.
The type of mapping. This can be one of the following:
Note Ensure that the communication port of the mount type that you choose is enabled on the switch. For example, when you are using CIFS as your mount type, ensure port 445 (which is its communication port) is enabled on the switch. Similarly, enable ports 80 for HTTP, 443 for HTTPS and 2049 for NFS when you use them.
• NFS —Network File System.
• CIFS —Common Internet File System.
• WWW(HTTP/HTTPS) —HTTP-based or HTTPS-based system.
Note Before mounting the virtual media, Cisco IMC tries to verify reachability to the end server by pinging the server.
Remote Share field
Remote File field
The URL of the image to be mapped. The format depends on the selected
Mount Type :
• NFS —Use serverip:/share .
• CIFS —Use //serverip/share .
• WWW(HTTP/HTTPS) —Use http[s]://serverip/share .
The name and location of the .iso or .img file in the remote share.
86
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Managing Remote Presence
Name
Mount Options field
Description
Creating a Cisco IMC Mapped vMedia Volume
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
87
Managing Remote Presence
Creating a Cisco IMC Mapped vMedia Volume
Name Description
Industry-standard mount options entered in a comma separated list. The options vary depending on the selected Mount Type .
If you are using NFS , leave the field blank or enter one or more of the following:
• ro
• rw
Note The folder, which is shared, should have write permissions to use read-write option. Read-write option is available only for .img files.
• nolock
• noexec
• soft
• port=VALUE
• timeo=VALUE
• retry=VALUE
• rsize=VALUE
• wsize=VALUE
• vers=VALUE
If you are using CIFS , leave the field blank or enter one or more of the following:
• ro
• rw
Note The folder, which is shared, should have write permissions to use read-write option. Read-write option is available only for .img files.
• soft
• nounix
• noserverino
• guest
• username=VALUE —ignored if guest is entered.
• password=VALUE —ignored if guest is entered.
• sec=VALUE
The protocol to use for authentication when communicating with
88
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Managing Remote Presence
Name
Step 7
User Name field
Password field
Click Save .
Creating a Cisco IMC Mapped vMedia Volume
Description the remote server. Depending on the configuration of CIFS share,
VALUE could be one of the following:
• None —No authentication is used
• Ntlm —NT LAN Manager (NTLM) security protocol. Use this option only with Windows 2008 R2 and Windows 2012
R2.
• Ntlmi —NTLMi security protocol. Use this option only when you enable Digital Signing in the CIFS Windows server.
• Ntlmssp —NT LAN Manager Security Support Provider
(NTLMSSP) protocol. Use this option only with Windows
2008 R2 and Windows 2012 R2.
• Ntlmsspi —NTLMSSPi protocol. Use this option only when you enable Digital Signing in the CIFS Windows server.
• Ntlmv2 —NTLMv2 security protocol. Use this option only with Samba Linux.
• Ntlmv2i —NTLMv2i security protocol. Use this option only with Samba Linux.
• vers=VALUE
Note The format of the VALUE should be x.x
If you are using WWW(HTTP/HTTPS) , leave the field blank or enter the following:
• noauto
Note Before mounting the virtual media, Cisco IMC tries to verify reachability to the end server by pinging the server.
• username=VALUE
• password=VALUE
The username for the specified Mount Type , if required.
The password for the selected username, if required.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
89
Managing Remote Presence
Viewing Cisco IMC-Mapped vMedia Volume Properties
Viewing Cisco IMC-Mapped vMedia Volume Properties
Before you begin
You must log in with admin privileges to perform this task.
Procedure
Step 1
Step 2
Step 3
Step 4
Step 5
Step 6
In the Navigation pane, click the Compute menu.
In the Compute menu, select a server.
In the work pane, click the Remote Management tab.
In the Remote Management tab, click the Virtual Media tab
Select a row from the Current Mappings table.
Click Properties and review the following information:
Name
Add New Mapping button
Description
Opens a dialog box that allows you to add a new image.
Properties button
Unmap
Volume button
Last Mapping Status column
Opens a dialog box that allows you to view or change the properties for the selected image.
Unmaps the mounted vMedia.
The status of the last mapping attempted.
The identity of the image.
Mount Type drop-down list
Remote Share field
Remote File field
Status field
The type of mapping.
The URL of the image.
The exact file location of the image.
The current status of the map. This can be one of the following:
• OK —The mapping is successful.
• In Progress —The mapping is in progress.
• Stale —Cisco IMC displays a text string with the reason why the mapping is stale.
• Error —Cisco IMC displays a text string with the reason for the error.
90
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Managing Remote Presence
Removing a Cisco IMC-Mapped vMedia Volume
Before you begin
You must log in with admin privileges to perform this task.
Procedure
Step 1
Step 2
Step 3
Step 4
Step 5
Step 6
In the Navigation pane, click the Compute menu.
In the Compute menu, select a server.
In the work pane, click the Remote Management tab.
In the Remote Management tab, click the Virtual Media tab
Select a row from the Current Mappings table.
Click Unmap .
Remapping an Existing Cisco IMC vMedia Image
Before you begin
You must log in with admin privileges to perform this task.
Procedure
Step 1
Step 2
Step 3
Step 4
Step 5
Step 6
In the Navigation pane, click the Compute menu.
In the Compute menu, select a server.
In the work pane, click the Remote Management tab.
In the Remote Management tab, click the Virtual Media tab
Select a row from the Current Mappings table.
Click Remap .
Deleting a Cisco IMC vMedia Image
Before you begin
You must log in with admin privileges to perform this task.
Procedure
Step 1 In the Navigation pane, click the Compute menu.
Removing a Cisco IMC-Mapped vMedia Volume
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
91
Managing Remote Presence
Virtual KVM Console
Step 2
Step 3
Step 4
Step 5
Step 6
In the Compute menu, select a server.
In the work pane, click the Remote Management tab.
In the Remote Management tab, click the Virtual Media tab
Select a row from the Current Mappings table.
Click Delete .
Virtual KVM Console
The vKVM console is an interface accessible from Cisco IMC that emulates a direct keyboard, video, and mouse (vKVM) connection to the server. The vKVM console allows you to connect to the server from a remote location.
Here are a few major advantages of using Cisco KVM Console:
• The Cisco KVM console provides connection to KVM, SOL, and vMedia whereas the Avocent KVM provides connection only to KVM and vMedia.
• In the KVM Console, the vMedia connection is established at the KVM Launch Manager and is available for all users.
• The KVM console offers you an advanced character replacement options for the unsupported characters while pasting text from the guest to the host.
• The KVM console provides you an ability to store the vMedia mappings on CIMC.
Instead of using CD/DVD or floppy drives physically connected to the server, the vKVM console uses virtual media, which are actual disk drives or disk image files that are mapped to virtual CD/DVD or floppy drives.
You can map any of the following to a virtual drive:
• CD/DVD or floppy drive on your computer
• Disk image files (ISO or IMG files) on your computer
• USB flash drive on your computer
• CD/DVD or floppy drive on the network
• Disk image files (ISO or IMG files) on the network
• USB flash drive on the network
You can use the vKVM console to install an OS on the server.
Launching KVM Console
You can launch the KVM console from either the Home page or from the Remote Management area.
92
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Managing Remote Presence
Virtual KVM Console
Procedure
Step 1
Step 2
Step 3
Step 4
Step 5
Step 6
Step 7
Step 8
Step 9
To launch the console from Home page, in the Navigation pane, click the Chassis menu.
In the Chassis menu, click Summary .
From the tool bar, click Launch vKVM .
Alternatively, in the Navigation pane, click the Compute menu.
In the Compute menu, select a server.
In the work pane, click the Remote Management tab.
In the Remote Management pane, click the Virtual KVM tab.
In the Virtual vKVM tab, click Launch vKVM console .
Required: Click the URL link displayed in the pop-up window to load the client application. You need to click the link every time you launch the vKVM console.
Virtual KVM Console
The vKVM console is an interface accessible from Cisco IMC that emulates a direct keyboard, video, and mouse (vKVM) connection to the server. It allows you to connect to and control the server from a remote location and to map physical locations to virtual drives that can by accessed by the server during this vKVM session.
File Menu
Menu Item Description
Paste Text From File / Send Text Opens the dialog box that allows you to paste content.
Capture to File Opens the Save dialog box that allows you to save the current screen as a JPG image.
Exit Closes the vKVM console.
View Menu
Menu Item
Keyboard
Refresh
Full Screen
Description
Displays the virtual keyboard for the vKVM console, which you can use to input data.
Updates the console display with the server's current video output.
Expands the vKVM console so that it fills the entire screen.
Macros Menu
Choose the keyboard shortcut you want to execute on the remote system.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
93
Managing Remote Presence
Virtual KVM Console
Menu Item
Static Macros menu
Manage
Tools Menu
Menu Item
Session Options
Session User List
Chat
Description
Displays a predefined set of macros.
Opens the Configure User Defined Macros dialog box, which allows you to create and manage macros.
System-defined macros cannot be deleted.
Description
Opens the Session Options dialog box that lets you specify:
• Scaling —Specify whether or not you want to maintain the aspect ratio of the screen. Check or uncheck the Maintain Aspect Ratio checkbox (checked by default).
• Mouse Acceleration : The mouse acceleration to use on the target system. The default is Absolute positioning (Windows, Newer
Linux & MAC OS X) . Other options are:
• Relative Positioning, no acceleration
• Relative Positioning (RHEL, Older Linux)
• Paste Text : Allows you to select to paste text from clipboard or a file.
Opens the Session User List dialog box that shows all the user IDs that have an active vKVM session.
Opens the Chat box to communicate with other users.
94
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Managing Remote Presence
Virtual KVM Console
Menu Item
Stats
Play Controls
Power Menu
Menu Item
Power On System
Power Off System
Reset System (warm boot)
Power Cycle System (cold boot)
Description
Opens the Stats dialog box, and the Live vKVM displays the following:
• Frame Rate : Frame rate measured in the number of frames per second.
• Bandwidth : Bandwidth measured in the number of KBs per second.
• Compression : Compression measured in the percentage of compression being used.
• Packet Rate : Packet rate measured in number of packets per second.
When vMedia is activated, the Virtual Media dialog box displays the following:
• Target Device : The type of local device.
• Mapped to : The type of local device or image file to which the host server device is mapped.
• Duration : The elapsed time of the device to map.
• Read Bytes : The number of bytes sent or received by the server.
Opens Cisco vKVM Playback window that allows you to choose a
.dvc
file.
Description
Powers on the system.
This option is disabled when the system is powered on and it is enabled when the system is not powered.
Powers off the system from the virtual console session.
This option is enabled when the system is powered on and disabled when the system is not powered on.
Reboots the system without powering it off.
This option is enabled when the system is powered on and disabled when the system is not powered on.
Turns off system and then back on.
This option is enabled when the system is powered on and disabled when the system is not powered on.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
95
Managing Remote Presence
Virtual KVM Console
Boot Device Menu
Name
No Override
Boot Device list
Description
Clicking this option enables the host to boot to the first device configured.
A list of boot devices that the server uses to boot from only for the next server boot, without disrupting the currently configured boot order. Once the server boots from the one time boot device, all its future reboots occur from the previously configured boot order. A maximum of 15 devices are displayed on the vKVM console.
Virtual Media Menu
Name
Create Image
Note This option is available only if you use the
Google Chrome web browser.
Description
Allows you to create an ISO image. Drag and drop files or folders in the Create Image dialog box; these files or folders are converted to an ISO image. You can use the Download ISO Image button to save the
ISO image to your local machine.
Activate Virtual Devices Activates a vMedia session that allows you to attach a drive or image file from your local computer or network.
Help Menu
Name
Help Topics
About vKVM Viewer
Description
Clicking this option brings you back to this window.
Displays the version number of the vKVM viewer.
Settings
The Settings icon is located on the top right hand corner of the HTML vKVM viewer window.
Name
Logged in as:
Description
Displays your user role name.
Cisco IMC Host Name Displays the host name.
96
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Managing Remote Presence
Configuring the Virtual KVM
Configuring the Virtual KVM
Before you begin
You must log in as a user with admin privileges to configure the virtual KVM.
Procedure
Step 1
Step 2
Step 3
Step 4
Step 5
Step 6
In the Navigation pane, click the Compute menu.
In the Compute menu, select a server.
In the work pane, click the Remote Management tab.
In the Remote Management pane, click the Virtual KVM tab.
In the vKVM Properties area on the Virtual KVM tab, complete the following fields:
Name
Enabled check box
Description
If checked, the virtual KVM is enabled.
Note The virtual media viewer is accessed through the KVM. If you disable the KVM console, Cisco IMC also disables access to all virtual media devices attached to the host.
Max Sessions drop-down list
Active Sessions field
Remote Port field
The maximum number of concurrent KVM sessions allowed. You can select any number between 1 and 4.
The number of KVM sessions running on the server.
The port used for KVM communication.
Enable Video Encryption check box
If checked, the server encrypts all video information sent through the
KVM.
Enable Local Server Video check box
If checked, the KVM session is also displayed on any monitor attached to the server.
Click Save Changes .
Enabling the Virtual KVM
Before you begin
You must log in as a user with admin privileges to enable the virtual KVM.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
97
Disabling the Virtual KVM
Procedure
Step 1
Step 2
Step 3
Step 4
Step 5
Step 6
In the Navigation pane, click the Compute menu.
In the Compute menu, select a server.
In the work pane, click the Remote Management tab.
In the Remote Management pane, click the Virtual KVM tab.
On the Virtual KVM tab, check the Enabled check box.
Click Save Changes .
Disabling the Virtual KVM
Before you begin
You must log in as a user with admin privileges to disable the virtual KVM.
Procedure
Step 1
Step 2
Step 3
Step 4
Step 5
Step 6
In the Navigation pane, click the Compute menu.
In the Compute menu, select a server.
In the work pane, click the Remote Management tab.
In the Remote Management pane, click the Virtual KVM tab.
On the Virtual KVM tab, uncheck the Enabled check box.
Click Save Changes .
Managing Remote Presence
98
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Managing User Accounts
C H A P T E R
8
This chapter includes the following sections:
•
Configuring Local Users, on page 99
•
Managing SSH Keys in User Accounts, on page 101
•
Non-IPMI User Mode, on page 105
•
Changing Password as a Non-Admin User, on page 106
•
•
Configuring Password Expiry Duration, on page 109
•
Enabling Password Expiry, on page 110
•
Configuring Account Lockout Details, on page 111
•
Configuring User Authentication Precedence, on page 111
•
Resetting User Credentials to Factory Default Values, on page 112
•
•
TACACS+ Authentication, on page 124
•
Viewing User Sessions, on page 126
Configuring Local Users
The Cisco IMC now implements a strong password policy wherein you are required to follow guidelines and set a strong password when you first log on to the server for the first time. The Local User tab displays a
Disable Strong Password button which allows you to disable the strong password policy and set a password of your choice by ignoring the guidelines. Once you disable the strong password, an Enable Strong Password button is displayed. By default, the strong password policy is enabled.
Before you begin
You must log in as a user with admin privileges to configure or modify local user accounts.
Procedure
Step 1
Step 2
Step 3
In the Navigation pane, click the Admin menu.
In the Admin menu, click User Management .
In the User Management pane, click the Local User Management tab.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
99
Managing User Accounts
Configuring Local Users
Step 4
Step 5
To configure or modify a local user account, click a row in the Local User Management pane and click
Modify User .
In the Modify User Details dialog box, update the following properties:
Name
ID field
Username field
Description
The unique identifier for the user.
The username for the user.
Enter between 1 and 16 characters.
Role Played field The role assigned to the user. This can be one of the following:
• read-only —A user with this role can view information but cannot make any changes.
• user —A user with this role can perform the following tasks:
• View all information
• Manage the power control options such as power on, power cycle, and power off
• Launch the vKVM console and virtual media
• Clear all logs
• Ping
• admin —A user with this role can perform all actions available through the GUI, CLI, and IPMI.
Note Any user with admin role will not have the option of Change
Password from the right top corner in Settings drop-down menu.
To change password as a non-admin user, select read-only or user role and not the admin role.
Enabled check box
Change Password check box
If checked, the user is enabled on Cisco IMC.
Enable this check box if you want to change the password.
100
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Managing User Accounts
Managing SSH Keys in User Accounts
Name
New Password field
Step 6
Step 7
Confirm Password field
Enter password information.
Click Save Changes .
Description
The password for this user name.
Click the Suggest button to get a system generated password that you may want to use.
When you move the mouse over the help icon beside the field, the following guidelines to set the password are displayed:
• The password must have a minimum of 8 and a maximum of 20 characters.
The password can have a maximum of 127 characters for non IPMI users.
• The password must not contain the user's name.
• The password must contain characters from three of the following four categories:
• English uppercase characters (A through Z).
• English lowercase characters (a through z).
• Base 10 digits (0 through 9).
• Non-alphabetic characters (!, @, #, $, %, ^, &, *, -, _,+ , =).
These guidelines are meant to define a strong password for the user, for security reasons. However, if you want to set a password of your choice ignoring these guidelines, click the Disable Strong Password button on the Local User Management tab. While setting a password when the strong password option is disabled, you can use between 1- 20 characters.
The password repeated for confirmation.
Managing SSH Keys in User Accounts
Configuring SSH Keys
You must log in as a user with admin privileges to view the SSH keys for all the users. If you are a non-admin user, you can view the SSH keys only for your account.
The Cisco IMC sessions authenticated using public SSH keys will be active even if the password has expired.
You can also start new sessions using the public SSH key even after the password has expired.
Account lockout option does not apply to the accounts that use public key authentication.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
101
Managing User Accounts
Adding SSH Keys
Before you begin
• You must log in as a user with admin privileges to configure SSH keys for all the users.
• Ensure that you have created a pair of SSH RSA keys, public and private.
• Ensure that the SSH keys are in .pem or .pub format.
Procedure
Step 1
Step 2
Step 3
Step 4
Step 5
Step 6
In the Navigation pane, click the Admin menu.
In the Admin menu, click the User Management tab.
In the User Management pane, click the Local User Management tab.
To view the number of SSH keys configured for an account, view the details in the SSH Key Count field.
To view the details of the SSH keys for an account, click a row in the Local User Management pane and click SSH Keys .
The SSH Keys window is displayed.
In the SSH Keys window, view the following properties:
Name
ID field
Comment
Key
Description
The unique identifier for the SSH key.
User name and remote server host name in the format username@hostname
Details of the public SSH key configured for a specific user.
What to do next
Add or modify the SSH keys.
Adding SSH Keys
Before you begin
• You must log in as a user with admin privileges to add SSH keys for all users.
• If you are a non-admin user, you can add SSH keys only for your account.
Procedure
Step 1
Step 2
Step 3
In the Navigation pane, click the Admin menu.
In the Admin menu, click the User Management tab.
In the User Management pane, click the Local User Management tab.
102
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Managing User Accounts
Modifying SSH Keys
Step 4
Step 5
Step 6
Step 7
Step 8
To add the SSH keys for an account, click a row in the Local User Management pane and click SSH Keys .
The SSH Keys window is displayed.
Click any of the radio buttons near the ID column.
Click Add Keys icon in the SSH Keys window to add the SSH key.
Select any of the following radio buttons to add the SSH key.
a) Select Paste SSH key .
Copy the public SSH key from the host and paste the key in the text field.
b) Select Upload from local .
Click Browse and navigate to the public SSH key file that you want to add.
c) Select Upload from remote location .
Enter the following details to upload the public key file from the remote location.
Name
Upload SSH key from drop-down list
Description
The remote server type. This can be one of the following:
• TFTP
• FTP
• SCP
• SFTP
• HTTP
Note If you choose FTP, SCP or SFTP, you will be prompted to enter your username and password.
Server IP/Hostname field
Path and Filename field
The IP address or hostname of the server on which the SSH key file is available
The path and filename of the public SSH key file on the remote server.
Click Upload SSH Key .
What to do next
Modify or delete the SSH keys.
Modifying SSH Keys
Before you begin
• You must log in as a user with admin privileges to modify the SSH keys for all the users.
• If you are a non-admin user, you can modify the SSH keys only for your account.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
103
Managing User Accounts
Modifying SSH Keys
Procedure
Step 1
Step 2
Step 3
Step 4
Step 5
Step 6
Step 7
Step 8
In the Navigation pane, click the Admin menu.
In the Admin menu, click the User Management tab.
In the User Management pane, click the Local User Management tab.
To view and modify the SSH keys, click a row in the Local User Management pane and click SSH Keys .
The SSH Keys window is displayed.
To modify the SSH key, review the list of SSH keys and select the desired row in the SSH Keys window.
Click the Modify Key icon.
Select any of the following radio buttons to modify the SSH key.
a) Select Paste SSH key .
Copy the updated public SSH key from the host and paste the key in the text field.
b) Select Upload from local .
Click Browse and navigate to the updated public key file that you want to upload.
c) Select Upload from remote location .
Enter the following details to upload the updated public key file from the remote location.
Name
Upload SSH key from drop-down list
Description
The remote server type. This can be one of the following:
• TFTP
• FTP
• SCP
• SFTP
• HTTP
Note If you choose FTP, SCP or SFTP, you will be prompted to enter your username and password.
Server IP/Hostname field
Path and Filename field
The IP address or hostname of the server on which the updated SSH key file is available
The path and filename of the updated public SSH key file on the remote server.
Click Upload SSH Key .
What to do next
Delete an SSH key.
104
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Managing User Accounts
Deleting SSH Keys
Deleting SSH Keys
Before you begin
• You must log in as a user with admin privileges to delete the SSH keys for all the users.
• If you are a non-admin user, you can delete the SSH keys only for your account.
Procedure
Step 1
Step 2
Step 3
Step 4
Step 5
Step 6
Step 7
In the Navigation pane, click the Admin menu.
In the Admin menu, click the User Management tab.
In the User Management pane, click the Local User Management tab.
To view and delete the SSH keys for a user account, click a row in the Local User Management pane and click SSH Keys .
The SSH Keys window is displayed.
To delete the SSH key, review the list of SSH keys and select the desired row in the SSH Keys window.
Click the Delete Key icon.
A pop-up window is displayed with the message Do you want to delete the selected SSH key?
Click Yes to confirm the deletion.
Non-IPMI User Mode
Release 4.1 introduces a new user configuration option called User Mode that allows you to switch between
IPMI and non-IPMI user modes. Introduction of the non-IPMI user mode provides enhanced password security for users and security enhancements to the BMC database that were restricted in earlier releases due to the constraints posed by the IPMI 2.0 standards. Non-IPMI user mode allows you to use 127 characters to set user passwords whereas users in IPMI mode are restricted to a password length of 20 characters. Non-IPMI user mode enables you to set stronger passwords for users configured in this mode.
You must consider the following configuration changes that occur while switching between user modes, when you:
• Switch to the non-IPMI mode, IPMI over LAN will not be supported.
• Switch from the non-IPMI to IPMI mode, deletes all the local users and reverts user credentials to default username and password. On subsequent login, you will be prompted to change the password.
User data is not affected when you switch from IPMI to non-IPMI mode.
• Downgrade the firmware to a versions lower than 4.1 and if the user mode is non-IPMI, deletes all the local users and reverts user credentials to default username and password. On subsequent login, you will be prompted to change the default password.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
105
Managing User Accounts
Switching between IPMI and Non-IPMI User Modes
Note When you reset to factory defaults, the user mode reverts to IPMI mode.
Switching between IPMI and Non-IPMI User Modes
Caution Performing this procedure restarts SSH, KVM, Webserver, XML API, and REST API services. It also removes the IPMI user support when you switch to Non-IPMI user mode.
Before you begin
You must log in as a user with admin privileges to perform this action.
Procedure
Step 1
Step 2
Step 3
In the Navigation pane, click the Admin tab.
In the Admin tab, click User Management .
Click the Disable IPMI User Mode or Enable IPMI User Mode button and click OK to confirm.
Changing Password as a Non-Admin User
Note To perform this task, you must first login as admin and add a user with read-only or user privileges. Only then, you will be able to login as a non-admin user to change the password.
Procedure
Step 1
Step 2
Step 3
Step 4
Step 5
Step 6
Login as an admin user.
In the Navigation pane, click the Admin menu.
In the Admin menu, click User Management .
In the User Management pane, click the Local User Management tab.
To configure or add a local user account, click a row in the Local User Management pane and click Add
User .
In the Add User dialog box, update the following properties by adding a user with read-only or user privileges:
Name Description
ID field The unique identifier for the user.
106
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Managing User Accounts
Name
Username field
Role Played field
Enabled check box
Change Password check box
Changing Password as a Non-Admin User
Description
The username for the user.
Enter between 1 and 16 characters.
The role assigned to the user. This can be one of the following:
• read-only —A user with this role can view information but cannot make any changes.
• user —A user with this role can perform the following tasks:
• View all information
• Manage the power control options such as power on, power cycle, and power off
• Launch the KVM console and virtual media
• Clear all logs
• Toggle the locator LED
• Set time zone
• Ping
• admin —A user with this role can perform all actions available through the GUI, CLI, and
IPMI.
Note To change password select read-only or user role and not the admin role.
If checked, the user is enabled on the Cisco IMC.
If checked, the user is enabled to change the password.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
107
Managing User Accounts
Changing Password as a Non-Admin User
Step 7
Step 8
Step 9
Name
New Password
Description
Enter the new password for this username.
Click the Suggest button to get a system generated password that you may want to use.
When you move the mouse over the help icon beside the field, the following guidelines to set the password are displayed:
• The password must have a minimum of 8 and a maximum of 14 characters.
For Non IPMI users, the password can have maximum of 127 characters.
• The password must not contain the User's Name.
• The password must contain characters from three of the following four categories:
• English uppercase characters (A through
Z).
• English lowercase characters (a through z).
• Base 10 digits (0 through 9).
• Non-alphabetic characters (!, @, #, $, %, ^,
&, *, -, _, , =, '').
These guidelines are meant to define a strong password for the user, for security reasons. However, if you want to set a password of your choice ignoring these guidelines, click the Disable Strong Password button on the Local User Management tab. While setting a password when the strong password option is disabled, you can use between 1- 20 characters.
The password repeated for confirmation.
Confirm Password field
Click Save Changes .
Note On changing the password, you will be logged out of Cisco IMC.
After creating a new user with read-only or user privileges, logout as admin.
Now, login with the newly created read-only or user role.
Change Password option is available in the right top corner in Settings drop-down menu.
When you click on the Settings icon, the drop-down lists the Change Password option. This option is visible only if you are logged in as a non-admin user.
If you do not see the Change Password option in the drop-down list, login as a non-admin user with read-only or user privileges.
108
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Managing User Accounts
Password Expiry
You can now use the Change Password option to change your password. As soon as the password is changed, you will be logged out automatically and will be prompted to login with the new password.
Password Expiry
You can set a shelf life for a password, after which it expires. As an administrator, you can set this time in days. This configuration would be common to all users. Upon password expiry, the user is notified on login and would not be allowed to login unless the password is reset.
Note When you downgrade to an older database, existing users are deleted. The database returns to default settings.
Previously configured users are cleared and the database is empty, that is, the database has the default username
- 'admin' and password - 'password'. Since the server is left with the default user database, the change default credential feature is enabled. This means that when the 'admin' user logs on to the database for the first time after a downgrade, the user must mandatorily change the default credential.
Password Set Time
A 'Password set time' is configured for every existing user, to the time when the migration or upgrade occurred.
For new users (users created after an upgrade), the Password Set time is configured to the time when the user was created, and the password is set. For users in general (new and existing), the Password Set Time is updated whenever the password is changed.
Configuring Password Expiry Duration
Before you begin
• You must enable password expiry.
Procedure
Step 1
Step 2
Step 3
Step 4
In the Navigation pane, click the Admin menu.
In the Admin menu, click User Management .
In the Local User Management pane (opens by default), click Password Expiration Details .
In the Password Expiration Details dialog box, update the following fields:
Name
Enable Password Expiry check box
Description
Checking this box allows you to configure the Password Expiry
Duration . Uncheck the check box to disable it.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
109
Managing User Accounts
Enabling Password Expiry
Step 5
Step 6
Name
Password Expiry Duration field
Description
The time period that you can set for the existing password to expire
(from the time you set a new password or modify an existing one). The range is between 1 to 3650 days.
Note Password expiry once set by the admin is applicable for all users that are subsequently created.
Password History field
Notification Period field
The number of occurrences when a password was entered. When this is enabled, you cannot repeat a password. Enter a value between 0 to 5.
Entering 0 disables this field.
Notifies the time by when the password expires. Enter a value between
0 to 15 days. Entering 0 disables this field.
Note The notification period time must be lesser than the password expiry duration.
Grace Period field Time period till when the existing password can still be used, after it expires. Enter a value between 0 to 5 days. Entering 0 disables this field.
Note The grace period time must be lesser than the password expiry duration.
Note The valid Password Expiry Duration must be greater than the Notification Period and the Grace
Period . If otherwise, you will see an User Password Expiry Policy configuration error .
Click Save Changes .
Optionally, click Reset Values to clear the text fields and reset the values you entered. Click Restore Defaults to revert to the default settings.
Enabling Password Expiry
Before you begin
Procedure
Step 1
Step 2
Step 3
Step 4
In the Navigation pane, click the Admin menu.
In the Admin menu, click User Management .
In the Local User Management pane (opens by default), click Password Expiration Details .
In the Password Expiration Details dialog box, check the Enable Password Expiry check box.
110
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Managing User Accounts
Configuring Account Lockout Details
The Password Expiry Duration text field becomes editable and you can configure the duration by entering a number in days.
What to do next
Configure password expiry duration.
Configuring Account Lockout Details
Procedure
Step 1
Step 2
Step 3
Step 4
Step 5
In the Navigation pane, click the Admin menu.
In the Admin menu, click User Management .
In the User Management pane, click the Local User Management tab.
In the Local User Management pane, click Account Lockout Details .
In the Account Lockout Details dialog box, complete the following:
Name Description
Allowed Attempts (0-20) field
Lockout Period (0-60 Minutes) field
Number of unsuccessful log in attempts allowed for a user before which it is locked out for the duration defined in Lockout Period .
The time duration, in minutes, for which the user account is locked out after the allowed attempts.
Disable User on Lockout check box Disables the user ID up on lockout.
Configuring User Authentication Precedence
Procedure
Step 1
Step 2
Step 3
Step 4
Step 5
In the Navigation pane, click the Admin menu.
In the Admin menu, click User Management .
In the User Management pane, click the Local User Management tab.
In the Local User Management pane, click Configure User Authentication Precedence .
In the Configure User Authentication Precedence dialog box, select the database for which you wish to update the priority.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
111
Managing User Accounts
Resetting User Credentials to Factory Default Values
Step 6 Use the Up or the Down arrow to change the priority of the database.
Resetting User Credentials to Factory Default Values
Caution You may lose current IP address settings, NIC port settings, NIC redundancy after performing this procedure.
Cisco recommends that you make a note of your current server settings before performing this procedure.
Before you begin
Ensure that your management Ethernet cable is plugged into the dedicated management port.
Procedure
Step 1
Step 2
Step 3
Step 4
Step 5
Step 6
Step 7
Step 8
Step 9
Step 10
Login as an admin user.
In the Navigation pane, click the Chassis menu.
In the Chassis menu, click Summary .
From the tool bar, click Launch KVM .
Alternatively, in the Navigation pane, click the Compute menu.
a.
In the Compute menu, select a server.
b.
In the work pane, click the Remote Management tab.
c.
In the Remote Management pane, click the Virtual KVM tab.
d.
In the Virtual KVM tab, click Launch HTML based KVM console .
From the Power menu, select Reset System .
When prompted, press F8 to enter the Cisco IMC Configuration Utility. This utility opens in the KVM console window.
Check the Factory Default check box, the server reverts to the factory defaults.
Press F5 to refresh the settings that you made. You might have to wait about 45 seconds until the new settings appear and the message Network settings configured is displayed before you reboot the server in the next step.
Press F10 to save your settings and reboot the server.
LDAP Servers
Cisco IMC supports directory services that organize information in a directory, and manage access to this information. Cisco IMC supports Lightweight Directory Access Protocol (LDAP), which stores and maintains directory information in a network. In addition, Cisco IMC supports Microsoft Active Directory (AD). Active
112
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Managing User Accounts
Configuring the LDAP Server
Directory is a technology that provides a variety of network services including LDAP-like directory services,
Kerberos-based authentication, and DNS-based naming. The Cisco IMC utilizes the Kerberos-based authentication service of LDAP.
When LDAP is enabled in the Cisco IMC, user authentication and role authorization is performed by the
LDAP server for user accounts not found in the local user database. The LDAP user authentication format is [email protected].
By checking the Enable Encryption check box in the LDAP Settings area, you can require the server to encrypt data sent to the LDAP server.
Configuring the LDAP Server
The Cisco IMC can be configured to use LDAP for user authentication and authorization. To use LDAP, configure users with an attribute that holds the user role and locale information for the Cisco IMC. You can use an existing LDAP attribute that is mapped to the Cisco IMC user roles and locales or you can modify the
LDAP schema to add a new custom attribute, such as the CiscoAVPair attribute, which has an attribute ID of 1.3.6.1.4.1.9.287247.1.
Important For more information about altering the schema, see the article at http://technet.microsoft.com/en-us/library/bb727064.aspx
.
Note This example creates a custom attribute named CiscoAVPair, but you can also use an existing LDAP attribute that is mapped to the Cisco IMC user roles and locales.
If you are using Group Authorization on the Cisco IMC LDAP configuration, then you can skip Steps 1-4 and perform the steps listed in the Configuring LDAP Settings and Group Authorization in Cisco IMC section.
The following steps must be performed on the LDAP server.
Procedure
Step 1
Step 2
Step 3
Step 4
Step 5
In the Navigation pane, click the Admin menu.
In the Admin menu, click User Management .
In the User Management pane, click LDAP .
Ensure that the LDAP schema snap-in is installed.
Using the schema snap-in, add a new attribute with the following properties:
Properties
Common Name
Value
CiscoAVPair
LDAP Display Name
Unique X500 Object ID
Description
CiscoAVPair
1.3.6.1.4.1.9.287247.1
CiscoAVPair
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
113
Managing User Accounts
Configuring LDAP Settings and Group Authorization in Cisco IMC
Step 6
Step 7
Properties
Syntax
Value
Case Sensitive String
Add the CiscoAVPair attribute to the user class using the snap-in: a) Expand the Classes node in the left pane and type U to select the user class.
b) Click the Attributes tab and click Add .
c) Type C to select the CiscoAVPair attribute.
d) Click OK .
Add the following user role values to the CiscoAVPair attribute, for the users that you want to have access to Cisco IMC:
Role CiscoAVPair Attribute Value shell:roles="admin" admin user read-only shell:roles="user" shell:roles="read-only"
Note For more information about adding values to attributes, see the article at http://technet.microsoft.com/en-us/library/bb727064.aspx
.
What to do next
Use the Cisco IMC to configure the LDAP server.
Configuring LDAP Settings and Group Authorization in Cisco IMC
Before you begin
You must log in as a user with admin privileges to perform this task.
Procedure
Step 1
Step 2
Step 3
Step 4
In the Navigation pane, click the Admin menu.
In the Admin menu, click User Management .
In the User Management pane, click LDAP .
In the LDAP Settings area, update the following properties:
Name
Enable LDAP check box
Description
If checked, user authentication and role authorization is performed first by the LDAP server, followed by user accounts that are not found in the local user database.
114
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Managing User Accounts
Configuring LDAP Settings and Group Authorization in Cisco IMC
Step 5
Name
Base DN
Domain field field
Enable Secure LDAP check box
Timeout (0 - 180) seconds
Description
Base Distinguished Name. This field describes where to load users and groups from.
It must be in the dc=domain,dc=com format for
Active Directory servers.
The IPv4 domain that all users must be in.
This field is required unless you specify at least one
Global Catalog server address.
If checked, the server enables secure LDAP and prompts you to download LDAP CA certificate. Refer
Downloading an LDAP CA Certificate, on page 122
to download LDAP CA certificate.
To delete an existing secure LDAP certificate, un-check this option. Follow the system prompts to confirm deletion.
The number of seconds the Cisco IMC waits until the
LDAP search operation times out.
If the search operation times out, Cisco IMC tries to connect to the next server listed on this tab, if one is available.
Note The value you specify for this field could impact the overall time.
Note If you check the Enable Secure LDAP check box, enter the fully qualified domain name (FQDN) of the LDAP server in the LDAP Server field. To resolve the FQDN of the LDAP server, configure the preferred DNS of Cisco IMC network with the appropriate DNS IP address.
In the Configure LDAP Servers area, update the following properties:
Name
Pre-Configure LDAP Servers radio button
Description
If checked, the Active Directory uses the pre-configured LDAP servers.
LDAP Servers fields
Server The IP address of the 6 LDAP servers.
If you are using Active Directory for LDAP, then servers 1, 2 and 3 are domain controllers, while servers 4, 5 and 6 are Global Catalogs. If you are not
Active Directory for LDAP, then you can configure a maximum of 6 LDAP servers.
Note You can provide the IP address of the host name as well.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
115
Managing User Accounts
Configuring LDAP Settings and Group Authorization in Cisco IMC
Step 6
Name
Port
Source drop-down list
Description
The port numbers for the servers.
If you are using Active Directory for LDAP, then for servers 1, 2 and 3, which are domain controllers, the default port number is 389. For servers 4, 5 and 6, which are Global Catalogs, the default port number is 3268.
LDAPS communication occurs over the TCP 636 port.
LDAPS communication to a global catalog server occurs over TCP 3269 port.
Use DNS to Configure LDAP Servers radio button If checked, you can use DNS to configure access to the LDAP servers.
DNS Parameters fields
Specifies how to obtain the domain name used for the
DNS SRV request. It can be one of the following:
• Extracted —specifies using domain name extracted-domain from the login ID
• Configured —specifies using the configured-search domain.
• Configured-Extracted —specifies using the domain name extracted from the login ID than the configured-search domain.
Domain to Search
Forest to Search
A configured domain name that acts as a source for a DNS query.
This field is disabled if the source is specified as
Extracted .
A configured forest name that acts as a source for a
DNS query.
This field is disabled if the source is specified as
Extracted .
In the Binding Parameters area, update the following properties:
116
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Managing User Accounts
Configuring LDAP Settings and Group Authorization in Cisco IMC
Step 7
Name
Method drop-down list
Description
It can be one of the following:
• Anonymous —requires NULL username and password. If this option is selected and the LDAP server is configured for Anonymous logins, then the user can gain access.
• Configured Credentials —requires a known set of credentials to be specified for the initial bind process. If the initial bind process succeeds, then the distinguished name (DN) of the user name is queried and re-used for the re-binding process.
If the re-binding process fails, then the user is denied access.
• Login Credentials —requires the user credentials. If the bind process fails, the user is denied access.
By default, the Login Credentials option is selected.
Binding DN
Password
The distinguished name (DN) of the user. This field is editable only if you have selected Configured
Credentials option as the binding method.
The password of the user. This field is editable only if you have selected Configured Credentials option as the binding method.
In the Search Parameters area, update the following fields:
Name
Filter Attribute
Description
This field must match the configured attribute in the schema on the LDAP server.
By default, this field displays sAMAccountName .
Group Attribute This field must match the configured attribute in the schema on the LDAP server.
By default, this field displays memberOf .
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
117
Managing User Accounts
Configuring LDAP Settings and Group Authorization in Cisco IMC
Step 8
Name
Attribute
Nested Group Search Depth (1-128)
Description
An LDAP attribute that contains the role and locale information for the user. This property is always a name-value pair. The system queries the user record for the value that matches this attribute name.
The LDAP attribute can use an existing LDAP attribute that is mapped to the Cisco IMC user roles and locales, or can modify the schema such that a new
LDAP attribute can be created. For example,
CiscoAvPair .
Parameter to search for an LDAP group nested within another defined group in an LDAP group map. The parameter defines the depth of a nested group search.
(Optional) In the Group Authorization area, update the following properties:
Name
LDAP Group Authorization check box
Description
If checked, user authentication is also done on the group level for LDAP users that are not found in the local user database.
If you check this box, Cisco IMC enables the Configure Group button.
Group Name column The name of the group in the LDAP server database that is authorized to access the server.
Group Domain column
Role column
The LDAP server domain the group must reside in.
The role assigned to all users in this LDAP server group. This can be one of the following:
• read-only —A user with this role can view information but cannot make any changes.
• user —A user with this role can perform the following tasks:
• View all information
• Manage the power control options such as power on, power cycle, and power off
• Launch the KVM console and virtual media
• Clear all logs
• Ping
• admin —A user with this role can perform all actions available through the GUI, CLI, and IPMI.
118
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Managing User Accounts
LDAP Certificates Overview
Name
Configure button
Description
Opens the Configure LDAP Group window for an active directory group with the same Group Name , Group Domain , and Role options listed above.
Once configured, click Save Changes .
Deletes an existing LDAP group.
Step 9
Delete button
Click Save Changes .
LDAP Certificates Overview
Cisco C-series servers allow an LDAP client to validate a directory server certificate against an installed CA certificate or chained CA certificate during an LDAP binding step. This feature is introduced in the event where anyone can duplicate a directory server for user authentication and cause a security breach due to the inability to enter a trusted point or chained certificate into the Cisco IMC for remote user authentication.
An LDAP client needs a new configuration option to validate the directory server certificate during the encrypted TLS/SSL communication.
Viewing LDAP CA Certificate Status
Procedure
Step 1
Step 2
Step 3
Step 4
In the Navigation pane, click the Admin menu.
In the Admin menu, click User Management .
In the User Management pane, click the LDAP tab.
In the Certificate Status area, view the following fields:
Name
Download Status
Description
This field displays the status of the LDAP CA certificate download.
Export Status This field displays the status of the LDAP CA certificate export.
Exporting an LDAP CA Certificate
Before you begin
You must log in as a user with admin privileges to perform this action.
You should have downloaded a signed LDAP CA Certificate before you can export it.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
119
Exporting an LDAP CA Certificate
Procedure
Step 1
Step 2
Step 3
Step 4
In the Navigation pane, click the Admin tab.
In the Admin menu, click User Management .
In the User Management pane, click the LDAP tab.
Click the Export LDAP CA Certificate link.
The Export LDAP CA Certificate dialog box appears.
Managing User Accounts
120
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Managing User Accounts
Name
Export to Remote Location
Export to Local Desktop
Exporting an LDAP CA Certificate
Description
Selecting this option allows you to choose the certificate from a remote location and export it. Enter the following details:
• • TFTP Server
• FTP Server
• SFTP Server
• SCP Server
• HTTP Server
Note If you chose SCP or SFTP as the remote server type while performing this action, a pop-up window is displayed with the message Server
(RSA) key fingerprint is
<server_finger_print _ID> Do you wish to continue?
. Click Yes or No depending on the authenticity of the server fingerprint.
The fingerprint is based on the host's public key and helps you to identify or verify the host you are connecting to.
• Server IP/Hostname field — The IP address or hostname of the server on which the LDAP CA certificate file should be exported. Depending on the setting in the Download Certificate from drop-down list, the name of the field may vary.
• Path and Filename field — The path and filename Cisco IMC should use when downloading the certificate from the remote server.
• Username field — The username the system should use to log in to the remote server. This field does not apply if the protocol is TFTP or
HTTP.
• Password field — The password for the remote server username. This field does not apply if the protocol is TFTP or HTTP.
Selecting this option allows you to choose the certificate stored on a drive that is local to the computer and export it.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
121
Managing User Accounts
Downloading an LDAP CA Certificate
Step 5 Click Export Certificate .
Downloading an LDAP CA Certificate
Note Only CA certificates or chained CA certificates must be used in Cisco IMC. By default, CA certificate is in
.cer format. If it is a chained CA certificate, then it needs to be converted to .cer format before downloading it to Cisco IMC.
Steps
1.
In the Navigation pane, click the Admin tab.
2.
In the Admin menu, click User Management .
3.
In the User Management pane, click the LDAP tab.
4.
Click the Download LDAP CA Certificate link.
The Download LDAP CA Certificate dialog box appears.
5.
Fill the required information in the Download LDAP CA Certificate dialog box.
122
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Managing User Accounts
Downloading an LDAP CA Certificate
Name
Upload from remote location radio button
Description
Selecting this option allows you to choose the certificate from a remote location and Upload it. Enter the following details:
• • TFTP Server
• FTP Server
• SFTP Server
• SCP Server
• HTTP Server
Note If you chose SCP or SFTP as the remote server type while performing this action, a pop-up window is displayed with the message Server (RSA) key fingerprint is <server_finger_print _ID> Do you wish to continue?
.
Click Yes or No depending on the authenticity of the server fingerprint.
The fingerprint is based on the host's public key and helps you to identify or verify the host you are connecting to.
• Server IP/Hostname field — The IP address or hostname of the server on which the LDAP CA certificate file should be stored.
Depending on the setting in the Upload Certificate from drop-down list, the name of the field may vary.
• Path and Filename field — The path and filename Cisco IMC should use when uploading the file to the remote server.
• Username field — The username the system should use to log in to the remote server. This field does not apply if the protocol is
TFTP or HTTP.
• Password field — The password for the remote server username.
This field does not apply if the protocol is TFTP or HTTP.
Upload through browser client radio button
Paste Certificate content button radio
Selecting this option allows you to navigate to the certificate stored on a drive that is local to the computer running the Cisco IMC GUI.
When you select this option, Cisco IMC GUI displays a Browse button that lets you navigate to the file you want to import.
Selecting this option allows you to copy the entire content of the signed certificate and paste it in the Paste certificate content text field.
Note Ensure the certificate is signed before uploading.
Upload Certificate button Allows you to Upload the certificate to the server.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
123
Managing User Accounts
Testing LDAP Binding
Testing LDAP Binding
Before you begin
You must log in as a user with admin privileges to perform this action.
Note If you checked the Enable Encryption and the Enable Binding CA Certificate check boxes, enter the fully qualified domain name (FQDN) of the LDAP server in the LDAP Server field. To resolve the FQDN of the
LDAP server, configure the preferred DNS of Cisco IMC network with the appropriate DNS IP address.
Procedure
Step 1
Step 2
Step 3
Step 4
Step 5
In the Navigation pane, click the Admin menu.
In the Admin menu, click User Management .
In the User Management pane, click the LDAP tab.
Click the Test LDAP Binding link.
The Test LDAP CA Certificate Binding dialog box appears.
Name
Username
Password field field
Description
Enter the user name.
Enter the corresponding password.
Click Test .
TACACS+ Authentication
Beginning with 4.1(3b) release, Cisco IMC supports Terminal Access Controller Access-Control System Plus
(TACACS+) user authentication. Cisco IMC supports up to six TACACS+ remote servers. Once a user is successfully authenticated, the username is appended with (TACACS+) . This is also displayed in the Cisco
IMC interfaces.
Refer
Enabling TACACS+ Authentication, on page 125
to enable TACACS+ Authentication. Cisco IMC also supports user authentication precedence in case TACACS+ remote servers are inaccessible. User authentication precedence can be configured using
Configuring User Authentication Precedence, on page 111 .
TACACS+ Server Configuration
Privilege level of a user is calculated based on the cisco-av-pair value configured for that user. A cisco-av-pair should be created on the TACACS+ server. Users cannot use any existing TACACS+ attributes.
Following three syntax are supported for the cisco-av-pair attribute:
• For admin privilege: cisco-av-pair=shell:roles=”admin”
124
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Managing User Accounts
Enabling TACACS+ Authentication
• For user privilege: cisco-av-pair=shell:roles=”user”
• For read-only privilege: cisco-av-pair=shell:roles=”read-only”
More roles, if required, can be added by using comma as a separator.
Note If cisco-av-pair is not configured on the TACACS+ server, then a user with that server has read-only privilege.
Enabling TACACS+ Authentication
Before you begin
Before configuring Terminal Access Controller Access-Control System (TACACS+) based user authentication, ensure that privilege level of a user is configured on TACACS+ server based on the cisco-av-pair value.
Procedure
Step 1
Step 2
Step 3
Step 4
In the Navigation pane, click the Admin menu.
In the Admin menu, click User Management .
In the User Management pane, click the TACACS+ tab.
Under the TACACS+ Properties area perform the following:
Name
Enabled check box
Description
Check this box to enable TACACS+ based user authentication.
Fallback only on no connectivity check box If checked, the authentication falls back to the next precedence database only in-case Cisco IMC is not able to connect to any of the configured TACACS+ servers.
Ensure to configure user authentication precedence.
Refer
Configuring User Authentication Precedence, on page 111 .
Timeout (for each server): (5 - 30) seconds field Time duration, in seconds, for which Cisco IMC waits for a response from each of the TACACS+ servers
Configuring TACACS+ Remote Server Settings
You can configure up to six TACACS+ remote servers.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
125
Managing User Accounts
Viewing User Sessions
Procedure
Step 1
Step 2
Step 3
Step 4
Step 5
In the Navigation pane, click the Admin menu.
In the Admin menu, click User Management .
In the User Management pane, click the TACACS+ tab.
Under the Server List area, click the radio button for the server ID which you wish to configure and click the Edit button.
Update the following fields:
Name
ID
Description
This is unique identifier of the server and is not user editable.
IP Address or Host Name
Port
Server key
The IP address at which the TACACS+ server is running.
The port on which TACACS+ server is running.
The same key that is configured on the TACACS+ server.
Repeat the same key for Confirm Server Key .
Viewing User Sessions
Procedure
Step 1
Step 2
Step 3
Step 4
In the Navigation pane, click the Admin menu.
In the Admin menu, click User Management .
In the User Management pane, click Session Management .
In the Sessions pane, view the following information about current user sessions:
Name
Session ID column
Description
The unique identifier for the session.
BMC Session ID
User Name
IP Address column column
The identifier for the BMC session.
The username for the user.
The IP address from which the user accessed the server. If this is a serial connection, it displays N/A .
126
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Managing User Accounts
Name
Session Type column
Action column
Viewing User Sessions
Description
The type of session the user chose to access the server. This can be one of the following:
• webgui — indicates the user is connected to the server using the web UI.
• CLI — indicates the user is connected to the server using CLI.
• serial — indicates the user is connected to the server using the serial port.
This column displays N/A when the SOL is enabled and Terminate when the SOL is disabled. You can terminate a session by clicking
Terminate on the web UI.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
127
Viewing User Sessions
Managing User Accounts
128
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
C H A P T E R
9
Configuring Chassis Related Settings
This chapter includes the following sections:
•
Managing Server Power, on page 129
•
Pinging a Hostname/IP Address from the Web UI, on page 130
•
Toggling the Locator LEDs, on page 130
•
Selecting a Time Zone, on page 131
Managing Server Power
Before you begin
You must log in with user or admin privileges to perform this task.
Procedure
Step 1
Step 2
Step 3
Step 4
In the Navigation pane, click the Chassis menu.
In the Chassis menu, click Summary .
In the toolbar above the work pane, click the Host Power link.
From the drop-down list, select one of the following options:
Actions Description
Power On
Power Off
Powers on the chosen server.
Powers off the chosen server, even if tasks are running on that server.
Important If any firmware or BIOS updates are in progress, do not power off or reset the server until those tasks are complete.
Power Cycle
Hard Reset
Powers off and powers on chosen server.
Reboots the chosen server.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
129
Configuring Chassis Related Settings
Pinging a Hostname/IP Address from the Web UI
Actions
Shut Down
Description
Shuts down the chosen server if the operating system supports that feature.
Pinging a Hostname/IP Address from the Web UI
Before you begin
You must log in with user or admin privileges to perform this task.
Procedure
Step 1
Step 2
Step 3
In the toolbar above the work pane, click the Ping icon.
In the Ping Details dialog box, update the following fields:
Actions Description
*Hostname/IP Address field
*Number of Retries field
*Timeout field
Hostname or IP address you want to reach out to.
The maximum number of retries allowed to ping the
IP address. The default value is 3. The valid range is from 1 to 10.
The maximum response time for a pinging activity.
The default value is 10 seconds. The valid range is from 1 to 20 seconds.
Displays results of the pinging activity.
Ping Status field
Details button
Ping button
Cancel button
Displays details of the pinging activity.
Pings the IP address.
Closes the dialog box without pinging.
Click Ping .
Toggling the Locator LEDs
Before you begin
You must log in with user or admin privileges to perform this task.
130
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Configuring Chassis Related Settings
Selecting a Time Zone
Procedure
Step 1
Step 2
Step 3
Step 4
In the Navigation pane, click the Chassis menu.
In the Chassis menu, click Summary .
In the toolbar above the work pane, click the Locator LED link.
Select Turn On Locator LED or Turn Off Locator LED .
Selecting a Time Zone
Before you begin
You must log in with admin privileges to perform this task.
Procedure
Step 1
Step 2
Step 3
Step 4
Step 5
In the Navigation pane, click the Chassis menu.
In the Chassis menu, click Summary .
In the Cisco Integrated Management Controller (Cisco IMC) Information area, click Select Timezone .
Select Timezone screen appears.
In the Select Timezone pop-up screen, mouse over the map and click on the location to select your time zone or choose your time zone from the Timezone drop-down menu.
Click OK .
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
131
Selecting a Time Zone
Configuring Chassis Related Settings
132
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
C H A P T E R
10
Configuring Network-Related Settings
This chapter includes the following sections:
•
Server NIC Configuration, on page 133
•
Common Properties Configuration, on page 140
•
•
•
Connecting to a VLAN, on page 143
•
Connecting to a Port Profile, on page 143
•
Configuring Individual Settings, on page 145
•
Network Security Configuration, on page 146
•
Network Time Protocol Settings, on page 147
Server NIC Configuration
Server NICs
NIC Mode
The NIC mode setting determines which ports can reach the Cisco IMC. The following network mode options are available, depending on your platform:
• Dedicated —The management port that is used to access the Cisco IMC.
• Cisco Card —Any port on the adapter card that can be used to access the Cisco IMC. The Cisco adapter card has to be installed in a slot with Network the Communications Services Interface protocol support
(NCSI).
• Shared LOM —Any LOM (LAN on Motherboard) port that can be used to access Cisco IMC.
• Shared LOM Extended —Any LOM port or adapter card port that can be used to access Cisco IMC.
The Cisco adapter card has to be installed in a slot with NCSI support.
Note Shared LOM and Shared LOM Extended ports are available only on some
C-series servers.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
133
Configuring Network-Related Settings
Server NICs
Note For other UCS C-Series M4 and M5 servers, the NIC mode is set to Shared LOM
Extended by default.
Default NIC Mode Setting :
• For UCS C-Series C125 M5 servers and S3260 servers, the NIC Mode is set to Cisco Card by default.
NIC Redundancy
The following NIC redundancy options are available, depending on the selected NIC mode and your platform:
• active-active —If supported, all ports that are associated with the configured NIC mode operate simultaneously. This feature increases throughput and provides multiple paths to the Cisco IMC.
• active-standby —If a port that is associated with the configured NIC mode fails, traffic fails over to one of the other ports associated with the NIC mode.
Note If you choose this option, make sure that all ports associated with the configured
NIC mode are connected to the same subnet to ensure that traffic is secure regardless of which port is used.
• None —In Dedicated mode, NIC redundancy is set to None .
The available redundancy modes vary depending on the selected network mode and your platform. For the available modes, see the Hardware Installation Guide (HIG) for the type of server you are using. The C-Series
HIGs are available at the following URL: http://www.cisco.com/en/US/products/ps10493/prod_installation_guides_list.html
VIC Slots
The VIC slot that can be used for management functions in Cisco card mode.
For C220 M6, VIC slot options are as follows:
Note For C220 M6 , after resetting to factory default settings, the slot precedence is as follows:
1.
mLOM
2.
Riser 1 - Slot 1
3.
Riser 3 - Slot 3
For C125 M5, VIC slot option is Riser 2 .
For C220 M4, C220 M5 and C240 M5 servers, VIC slot options are as follows:
• Riser 1 —Slot 1 is selected.
• Riser 2 —Slot 2 is selected.
134
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Configuring Network-Related Settings
• FLEX LOM —Slot 3 (MLOM) is selected.
For C240 M4 servers, VIC slot options are as follows:
• Riser 1 —Slot 2 is the primary slot, but you can also use slot 1.
• Riser 2 —Slot 5 is the primary slot, but you can also use slot 4.
• FLEX LOM —Slot 7 (MLOM) is selected.
For C480 M5 ML servers, Cisco card mode slot is Slot 11 and Slot 12.
The following options are available only on some UCS C-Series servers:
• 4
• 5
• 9
• 10
Note This option is available only on some UCS C-Series servers.
Configuring Server NICs
Configure a server NIC when you want to set the NIC mode and NIC redundancy.
Before you begin
You must log in as a user with admin privileges to configure the NIC.
Procedure
Step 1
Step 2
Step 3
In the Navigation pane, click the Admin menu.
In the Admin menu, click Networking .
In the NIC Properties area, update the following properties:
Configuring Server NICs
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
135
Configuring Network-Related Settings
Configuring Server NICs
Name
NIC Mode drop-down list
Description
The ports that can be used to access Cisco IMC. This can be one of the following:
• Dedicated —The management port that is used to access the Cisco
IMC.
• Cisco Card —Any port on the adapter card that can be used to access Cisco IMC. The Cisco adapter card has to be installed in a slot with Network the Communications Services Interface protocol support (NCSI).
• Shared LOM —Any LOM (LAN on Motherboard) port that can be used to access Cisco IMC.
• Shared LOM Extended —Any LOM port or adapter card port that can be used to access Cisco IMC. The Cisco adapter card has to be installed in a slot with NCSI support.
Note Shared LOM and Shared LOM Extended ports are available only on some C-series servers.
Note For other UCS C-Series M4 and M5 servers, the NIC mode is set to Shared LOM Extended by default.
Default NIC Mode Setting :
• For UCS C-Series C125 M5 servers and S3260 servers, the NIC
Mode is set to Cisco Card by default.
136
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Configuring Network-Related Settings
Name
VIC Slot drop-down list
Description
Configuring Server NICs
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
137
Configuring Server NICs
Name
Configuring Network-Related Settings
Description
The VIC slot that can be used for management functions in Cisco card mode.
For C220 M6, VIC slot options are as follows:
Note For C220 M6 , after resetting to factory default settings, the slot precedence is as follows: a.
mLOM b.
Riser 1 - Slot 1 c.
Riser 3 - Slot 3
For C125 M5, VIC slot option is Riser 2 .
For C220 M4, C220 M5 and C240 M5 servers, VIC slot options are as follows:
• Riser 1 —Slot 1 is selected.
• Riser 2 —Slot 2 is selected.
• FLEX LOM —Slot 3 (MLOM) is selected.
For C240 SD M5 servers, VIC slot options are as follows:
• For servers with PCIe Riser 1 and 2B combination:
• If you select Riser1, you must install the VIC in slot 2.
• If you select Riser2, you must install the VIC in slot 5.
• For servers with PCIe Riser 1C and 2E combination:
• If you select Riser1, you must install the VIC in slot 1.
• If you select Riser2, you must install the VIC in slot 2.
• If you select Flex-LOM, you must install an mLOM-style VIC in the mLOM slot.
For C480 M5 ML servers, Cisco card mode slot is Slot 11 and Slot 12.
The following options are available only on some UCS C-Series servers:
• 4
• 5
• 9
• 10
For C240 M4 servers, VIC slot options are as follows:
• Riser 1 —Slot 2 is the primary slot, but you can also use slot 1.
138
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Configuring Network-Related Settings
Configuring Server NICs
Step 4
Name Description
• Riser 2 —Slot 5 is the primary slot, but you can also use slot 4.
• FLEX LOM —Slot 7 (MLOM) is selected.
Note This option is available only on some UCS C-Series servers.
SIOC Slot drop-down list Configures Cisco IMC network mode. Based on the card present in the
System IO Controller (SIOC1), network mode can be changed to either
1 or 2.
Note This option is available only on some UCS S-Series servers.
NIC Redundancy drop-down list The available NIC redundancy options depend on the selected NIC mode and the model of the server that you are using. If you do not see a particular option, it is not available for the selected mode or server model.
This can be one of the following:
• active-active —If supported, all ports that are associated with the configured NIC mode operate simultaneously. This feature increases throughput and provides multiple paths to Cisco IMC.
• active-standby —If a port that is associated with the configured
NIC mode fails, traffic fails over to one of the other ports associated with the NIC mode.
Note • If you choose this option, make sure that all ports associated with the configured NIC mode are connected to the same VLAN to ensure that traffic is secure regardless of which port is used.
• When using active-active , do not configure a port-channel in the upstream switch for the member interfaces. A port-channel can be configured when using active-standby .
MAC Address field
• None —In Dedicated mode, NIC redundancy is set to None .
The MAC address of the Cisco IMC network interface that is selected in the NIC Mode field.
Click Save Changes .
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
139
Configuring Network-Related Settings
Common Properties Configuration
Common Properties Configuration
Overview to Common Properties Configuration
Hostname
The Dynamic Host Configuration Protocol (DHCP) enhancement is available with the addition of the hostname to the DHCP packet, which can either be interpreted or displayed at the DHCP server side. The hostname, which is now added to the options field of the DHCP packet, sent in the DHCP DISCOVER packet that was initially sent to the DHCP server.
The default hostname of the server is changed from ucs-c2XX to CXXX-YYYYYY, where XXX is the model number and YYYYYY is the serial number of the server. This unique string acts as a client identifier, allows you to track and map the IP addresses that are leased out to Cisco IMC from the DHCP server. The default serial number is provided by the manufacturer as a sticker or label on the server to help you identify the server.
Dynamic DNS
Dynamic DNS (DDNS) is used to add or update the resource records on the DNS server from Cisco IMC.
You can enable Dynamic DNS by using either the web UI or CLI. When you enable the DDNS option, the
DDNS service records the current hostname, domain name, and the management IP address and updates the resource records in the DNS server from Cisco IMC.
Note The DDNS server deletes the prior resource records (if any) and adds the new resource records to the DNS server if any one of the following DNS configuration is changed:
• Hostname
• Domain name in the LDAP settings
• When DDNS and DHCP are enabled, if the DHCP gets a new IP address or DNS IP or domain name due to a change in a network or a subnet.
• When DHCP is disabled and if you set the static IP address by using CLI or web UI.
• When you enter the dns-use-dhcp command.
Dynamic DNS Update Domain — You can specify the domain. The domain could be either main domain or any sub-domain. This domain name is appended to the hostname of the Cisco IMC for the DDNS update.
Configuring Common Properties
Use common properties to describe your server.
Before you begin
You must log in as a user with admin privileges to configure common properties.
140
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Configuring Network-Related Settings
Configuring IPv4
Procedure
Step 1
Step 2
Step 3
Step 4
In the Navigation pane, click the Admin menu.
In the Admin menu, click Networking .
In the Common Properties area, update the following properties:
Name Description
Management Hostname field
Dynamic DNS check box
Dynamic DNS Update Domain field
The user-defined management hostname of the system that manages the various components of Cisco IMC.
If checked, updates the resource records to the DNS from Cisco IMC.
The domain name that is appended to a hostname for a Dynamic DNS (DDNS) update. If left blank, only a hostname is sent to the DDNS update request.
Dynamic DNS Refresh Interval field The time set to refresh the DNS.
Set a value between 0 and 8736 hours. If set to 0, it is disabled.
Click Save Changes .
Configuring IPv4
Before you begin
You must log in as a user with admin privileges to configure IPv4.
Procedure
Step 1
Step 2
Step 3
In the Navigation pane, click the Admin menu.
In the Admin menu, click Networking .
In the IPv4 Properties area, update the following properties:
Name
Enable IPv4 check box
Description
If checked, IPv4 is enabled.
If checked, Cisco IMC uses DHCP.
Use DHCP check box
Management IP Address field
Subnet Mask field
The management IP address. An external virtual IP address that helps manage the CMCs and BMCs.
The subnet mask for the IP address.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
141
Configuring Network-Related Settings
Configuring IPv6
Step 4
Name
Gateway field
Obtain DNS Server Addresses from DHCP check box
Preferred DNS Server field
Alternate DNS Server field
Description
The gateway for the IP address.
If checked, Cisco IMC retrieves the DNS server addresses from DHCP.
The IP address of the primary DNS server.
The IP address of the secondary DNS server.
Click Save Changes .
Configuring IPv6
Before you begin
You must log in as a user with admin privileges to configure IPv6.
Procedure
Step 1
Step 2
Step 3
In the Navigation pane, click the Admin menu.
In the Admin menu, click Networking .
In the IPv6 Properties area, update the following properties:
Name
Enable IPv6
Use DHCP check box check box
Description
If checked, IPv6 is enabled.
If checked, the Cisco IMC uses DHCP.
Note Only stateful DHCP is supported.
Management IP Address field Management IPv6 address.
Note Only global unicast addresses are supported.
Prefix Length
Gateway field field The prefix length for the IPv6 address. Enter a value within the range
1 to 127. The default value is 64.
The gateway for the IPv6 address.
Note Only global unicast addresses are supported.
Obtain DNS Server Addresses from DHCP check box
If checked, the Cisco IMC retrieves the DNS server addresses from
DHCP.
Note You can use this option only when the enabled.
Use DHCP option is
142
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Configuring Network-Related Settings
Connecting to a VLAN
Name
Preferred DNS Server field
Alternate DNS Server field
Link Local Address field
SLAAC Address field
Description
The IPv6 address of the primary DNS server.
The IPv6 address of the secondary DNS server.
The link local address for the IPv6 address.
The Stateless Address Auto Configuration (SLAAC) depends on the
Router Advertisement (RA) of the network.
Step 4 Click Save Changes .
Connecting to a VLAN
Before you begin
You must be logged in as admin to connect to a VLAN.
Procedure
Step 1
Step 2
Step 3
Step 4
In the Navigation pane, click the Admin menu.
In the Admin menu, click Networking .
In the VLAN Properties area, update the following properties:
Name
Enable VLAN check box
Description
If checked, the Cisco IMC is connected to a virtual LAN.
Note You can configure a VLAN or a port profile, but you cannot use both. If you want to use a port profile, make sure that this check box is not checked.
VLAN ID
Priority field field
Click Save Changes .
The VLAN ID.
The priority of this system on the VLAN.
Connecting to a Port Profile
Before you begin
You must be logged in as admin to connect to a port profile.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
143
Configuring Network-Related Settings
Connecting to a Port Profile
Procedure
Step 1
Step 2
Step 3
In the Navigation pane, click the Admin menu.
In the Admin menu, click Networking .
In the Port Properties area, update the following properties:
Name
Port Profile field
Description
Details of the Port Profile field.
Auto Negotiation check box Using this option, you can either set the network port speed and duplex values for the switch, or allow the system to automatically derive the values from the switch. This option is available for dedicated mode only.
• If checked, the network port speed and duplex settings are ignored by the system and Cisco IMC retains the speed at which the switch is configured.
• If unchecked, you can configure the network port speed and duplex values.
Admin Mode Area Network Port Speed field
The network speed of the port. This can be one of the following:
• 10 Mbps
• 100 Mbps
• 1 Gbps
The default value is 100 Mbps. In the Dedicated mode, if you disable Auto Negotiation , you can configure the network speed and duplex values.
Note • Before changing the port speed, ensure that the switch you connected to has the same port speed.
Duplex drop-down list
The duplex mode for the Cisco IMC management port.
This can be one of the following:
• Half
• Full
By default, the duplex mode is set to Full .
144
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Configuring Network-Related Settings
Configuring Individual Settings
Name
Operation Mode Area
Description
Displays the operation network port speed and duplex values.
If you checked the Auto Negotiation check box, the network port speed and duplex details of the switch are displayed. If unchecked, the network port speed and duplex values that you set at the Admin Mode are displayed.
Step 4 Click Save Changes .
Configuring Individual Settings
This functionality is applicable only for Cisco UCS S-Series servers.
Before you begin
You must be logged in as admin to configure the settings.
Procedure
Step 1
Step 2
Step 3
Step 4
In the Navigation pane, click the Admin menu.
In the Admin menu, click Networking .
In the Individual Settings area, review and update the following fields for CMC 1 , CMC 2 , BMC 1 and BMC
2 in their respective areas:
Name
Hostname field
Description
The user-defined hostname. By default, the hostname appears in
CXXX-YYYYYY format, where XXX is the model number and
YYYYYY is the serial number of the server.
The MAC address of the component.
MAC Address field
IPv4 Address field
IPv6 Address field
Link Local Address field
The IPv4 address of the component.
The IPv6 address of the component.
The link local address for the component's IPv6 address.
Click Save Changes .
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
145
Configuring Network-Related Settings
Network Security Configuration
Network Security Configuration
Network Security
The Cisco IMC uses IP blocking as network security. IP blocking prevents the connection between a server or website and certain IP addresses or ranges of addresses. IP blocking effectively bans undesired connections from those computers to a website, mail server, or other Internet servers.
IP banning is commonly used to protect against denial of service (DoS) attacks. Cisco IMC bans IP addresses by setting up an IP blocking fail count.
Configuring Network Security
Configure network security if you want to set up an IP blocking fail count.
Before you begin
You must log in as a user with admin privileges to configure network security.
Procedure
Step 1
Step 2
Step 3
Step 4
In the Navigation pane, click the Admin menu.
In the Networking pane, click Network Security .
In the IP Blocking Properties area, update the following properties:
Name
Enable IP Blocking check box
Description
Check this box to enable IP blocking.
IP Blocking Fail Count field
IP Blocking Fail Window
IP Blocking Penalty Time field field
The number of times a user can attempt to log in unsuccessfully before the system locks that user out for a specified length of time.
The number of unsuccessful login attempts must occur within the time frame specified in the IP Blocking Fail Window field.
Enter an integer between 3 and 10.
The length of time, in seconds, in which the unsuccessful login attempts must occur in order for the user to be locked out.
Enter an integer between 60 and 280.
The number of seconds the user remains locked out if they exceed the maximum number of login attempts within the specified time window.
Enter an integer between 300 and 900.
In the IP Filtering (Whitelisting) area, update the following properties:
146
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Configuring Network-Related Settings
Network Time Protocol Settings
Step 5
Name
Enable IP Filtering check box
IP Filter fields
Description
Check this box to enable IP filtering.
To provide secure access to the server, you can now set a filter to allow only a selected set of IPs to access it. This option provides four slots for storing IP addresses (IP Filter 1, 2, 3, and 4). You can either assign a single IP address or a range of IP addresses while setting the IP filters.
Once you set the IP filter, you would be unable to access the server using any other IP address.
Click Save Changes .
Network Time Protocol Settings
Network Time Protocol Service Setting
By default, when Cisco IMC is reset, it synchronizes the time with the host. With the introduction of the NTP service, you can configure Cisco IMC to synchronize the time with an NTP server. The NTP server does not run in Cisco IMC by default. You must enable and configure the NTP service by specifying the IP/DNS address of at least one server or a maximum of four servers that function as NTP servers or time source servers.
When you enable the NTP service, Cisco IMC synchronizes the time with the configured NTP server. The
NTP service can be modified only through Cisco IMC.
Note To enable the NTP service, it is preferable to specify the IP address of a server rather than the DNS address.
Configuring Network Time Protocol Settings
Configuring NTP disables the IPMI Set SEL time command.
Before you begin
You must log in with admin privileges to perform this task.
Procedure
Step 1
Step 2
Step 3
Step 4
In the Navigation pane, click the Admin menu.
In the Admin menu, click Networking .
In the Networking pane, click NTP Setting .
In the NTP Properties area, update the following properties:
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
147
Configuring Network-Related Settings
Configuring Network Time Protocol Settings
Name
NTP Enabled check box
Server 1 field
Server 2 field
Server 3 field
Server 4 field
Status message
Description
Check this box to enable the NTP service.
The IP/DNS address of one of the four servers that act as an NTP server or the time source server.
The IP/DNS address of one of the four servers that act as an NTP server or the time source server.
The IP/DNS address of one of the four servers that act as an NTP server or the time source server.
The IP/DNS address of one of the four servers that act as an NTP server or the time source server.
Indicates whether or not the server is able to synchronize its time with the remote NTP server. It is an eight bit integer indicating the stratum level of the local clock. This can be one of the following:
• 0—Unspecified or invalid
• 1—Primary server
• 2-15—Secondary server (via NTP)
• 16—Unsynchronized
• 17-255—Reserved
Step 5 Click Save Changes .
148
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
C H A P T E R
11
Managing Network Adapters
This chapter includes the following sections:
•
Overview of the Cisco UCS C-Series Network Adapters, on page 149
•
Configuring Network Adapter Properties, on page 151
•
•
•
Backing Up and Restoring the Adapter Configuration, on page 199
•
Resetting the Adapter, on page 202
Overview of the Cisco UCS C-Series Network Adapters
Note The procedures in this chapter are available only when a Cisco UCS C-Series network adapter is installed in the chassis.
A Cisco UCS C-Series network adapter can be installed to provide options for I/O consolidation and virtualization support. The following adapters are available:
• Cisco UCS VIC 1225 Virtual Interface Card
• Cisco UCS VIC 1227T Virtual Interface Card
• Cisco UCS VIC 1385 Virtual Interface Card
• Cisco UCS VIC 1387 Virtual Interface Card
• Cisco UCS VIC 1455 Virtual Interface Card
• Cisco UCS VIC 1457 Virtual Interface Card
• Cisco UCS VIC 1495 Virtual Interface Card
• Cisco UCS VIC 1497 Virtual Interface Card
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
149
Managing Network Adapters
Overview of the Cisco UCS C-Series Network Adapters
Note You must have same generation VIC cards on a server. For example, you cannot have a combination of 3rd generation and 4th generation VIC cards on a single server.
The interactive UCS Hardware and Software Interoperability Utility lets you view the supported components and configurations for a selected server model and software release. The utility is available at the following
URL: http://www.cisco.com/web/techdoc/ucs/interoperability/matrix/matrix.html
Cisco UCS VIC 1225 Virtual Interface Card
The Cisco UCS VIC 1225 Virtual Interface Card is a high-performance, converged network adapter that provides acceleration for the various new operational modes introduced by server virtualization. It brings superior flexibility, performance, and bandwidth to the new generation of Cisco UCS C-Series Rack-Mount
Servers.
Cisco UCS VIC 1385 Virtual Interface Card
The Cisco UCS VIC 1385 Virtual Interface Cardis a dual-port Enhanced Quad Small Form-Factor Pluggable
(QSFP) 40 Gigabit Ethernet and Fibre Channel over Ethernet (FCoE)-capable half-height PCI Express (PCIe) card designed exclusively for Cisco UCS C-Series Rack Servers. It incorporates Cisco’s next-generation converged network adapter (CNA) technology, with a comprehensive feature set, providing investment protection for future feature software releases.
Cisco UCS VIC 1227T Virtual Interface Card
The Cisco UCS VIC 1227T Virtual Interface Card is a dual-port 10GBASE-T (RJ-45) 10-Gbps Ethernet and
Fibre Channel over Ethernet (FCoE)–capable PCI Express (PCIe) modular LAN-on-motherboard (mLOM) adapter designed exclusively for Cisco UCS C-Series Rack Servers. New to Cisco rack servers, the mLOM slot can be used to install a Cisco VIC without consuming a PCIe slot, which provides greater I/O expandability.
It incorporates next-generation converged network adapter (CNA) technology from Cisco, providing Fibre
Channel connectivity over low-cost twisted pair cabling with a bit error rate (BER) of 10 to 15 up to 30 meters and investment protection for future feature releases.
Cisco UCS VIC 1387 Virtual Interface Card
The Cisco UCS VIC 1387 Virtual Interface Card is a dual-port Enhanced Quad Small Form-Factor Pluggable
(QSFP) 40 Gigabit Ethernet and Fibre Channel over Ethernet (FCoE)-capable half-height PCI Express (PCIe) card designed exclusively for Cisco UCS C-Series Rack Servers. It incorporates Cisco’s next-generation converged network adapter (CNA) technology, with a comprehensive feature set, providing investment protection for future feature software releases.
Cisco UCS VIC 1455 Virtual Interface Card
The Cisco UCS VIC 1455 is a quad-port Small Form-Factor Pluggable (SFP28) half-height PCIe card designed for M5 generation of Cisco UCS C-Series rack servers. The card supports 10/25-Gbps Ethernet or FCoE. It incorporates Cisco’s next-generation CNA technology and offers a comprehensive feature set, providing investment protection for future feature software releases. The card can present PCIe standards-compliant interfaces to the host, and these can be dynamically configured as NICs and HBAs.
150
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Managing Network Adapters
Configuring Network Adapter Properties
Cisco UCS VIC 1457 Virtual Interface Card
The Cisco UCS VIC 1457 is a quad-port Small Form-Factor Pluggable (SFP28) mLOM card designed for
M5 generation of Cisco UCS C-Series rack servers. The card supports 10/25-Gbps Ethernet or FCoE. It incorporates Cisco’s next-generation CNA technology and offers a comprehensive feature set, providing investment protection for future feature software releases. The card can present PCIe standards-compliant interfaces to the host, and these can be dynamically configured as NICs and HBAs.
Cisco UCS VIC 1495 Virtual Interface Card
The Cisco UCS VIC 1495 is a dual-port Small Form-Factor (QSFP28) PCIe card designed for the M5 generation of Cisco UCS C-Series Rack Servers. The card supports 40/100-Gbps Ethernet and FCoE. The card can present
PCIe standards-compliant interfaces to the host, and these can be dynamically configured as NICs and HBAs.
Cisco UCS VIC 1497 Virtual Interface Card
The Cisco VIC 1497 is a dual-port Small Form-Factor (QSFP28) mLOM card designed for the M5 generation of Cisco UCS C-Series Rack Servers. The card supports 40/100-Gbps Ethernet and FCoE. The card can present
PCIe standards-compliant interfaces to the host, and these can be dynamically configured as NICs and HBAs.
Configuring Network Adapter Properties
Before you begin
• You must log in as a user with admin privileges to perform this task.
• The server must be powered on, or the properties will not display.
Procedure
Step 1
Step 2
Step 3
In the Navigation pane, click the Networking menu.
In the Networking menu, select the adapter card that you want to view.
In the Adapter Card Properties area under the General tab, review the following information:
Name Description
PCI Slot
Vendor field field
Product Name field
The PCI slot in which the adapter is installed.
The vendor for the adapter.
The product name for the adapter.
Product ID field
Serial Number field
Version ID field
PCI Link field
Hardware Revision field
The product ID for the adapter.
The serial number for the adapter.
The version ID for the adapter.
The server to which the PCIe link is established.
The hardware revision for the adapter.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
151
Managing Network Adapters
Configuring Network Adapter Properties
Name
Cisco IMC Management Enabled field
Configuration Pending field
ISCSI Boot Capable field
CDN Capable field usNIC Capable
Port Channel Capable
Description field field
Enable FIP Mode field check box
Description
If this field displays yes , then the adapter is functioning in Cisco Card Mode and passing Cisco
IMC management traffic through to the server Cisco
IMC.
If this field displays yes , the adapter configuration has changed in Cisco IMC but these changes have not been communicated to the host operating system.
To activate the changes, an administrator must reboot the adapter.
Whether iSCSI boot is supported on the adapter.
Whether CDN is supported on the adapter.
Whether the adapter and the firmware running on the adapter support the usNIC.
Indicates whether Port Channel is supported on the adapter.
Note This option is available only on some of the adapters and servers.
A user-defined description for the adapter.
You can enter between 1 and 63 characters.
If checked, then FCoE Initialization Protocol (FIP) mode is enabled. FIP mode ensures that the adapter is compatible with current FCoE standards.
Note We recommend that you use this option only when explicitly directed to do so by a technical support representative.
152
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Managing Network Adapters
Configuring Network Adapter Properties
Name
Enable LLDP check box
Enable VNTAG Mode
Port Channel check box check box
Description
Note For LLDP change to be effective, it is required that you reboot the server.
In case of S3260 chassis with two nodes, ensure to reboot the secondary node after making LLDP changes in the primary node.
If checked, then Link Layer Discovery Protocol
(LLDP) enables all the Data Center Bridging
Capability Exchange protocol (DCBX) functionality, which includes FCoE, priority based flow control.
By default, LLDP option is enabled.
Note We recommend that you do not disable
LLDP option, as it disables all the DCBX functionality.
If VNTAG mode is enabled:
• vNICs and vHBAs can be assigned to a specific channel.
• vNICs and vHBAs can be associated to a port profile.
• vNICs can fail over to another vNIC if there are communication problems.
This option is enabled by default.
When Port channel is enabled, two vNICs and two vHBAs are available for use on the adapter card.
When disabled, four vNICs and four vHBAs are available for use on the adapter card.
Note This option is available only on some of the adapters and servers.
Step 4 In the Firmware area, review the following information:
Name
Running Version field
Description
The firmware version that is currently active.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
153
Managing Network Adapters
Configuring Network Adapter Properties
Name
Backup Version
Startup Version field field
Bootloader Version
Status field field
Description
The alternate firmware version installed on the adapter, if any. The backup version is not currently running. To activate it, administrators can click Activate Firmware in the Actions area.
Note When you install new firmware on the adapter, any existing backup version is deleted and the new firmware becomes the backup version. You must manually activate the new firmware if you want the adapter to run the new version.
The firmware version that will become active the next time the adapter is rebooted.
The bootloader version associated with the adapter card.
The status of the last firmware activation that was performed on this adapter.
Note The status is reset each time the adapter is rebooted.
Step 5 Click the External Ethernet Interfaces link to review the following information:
Note External Ethernet Interfaces opens in a different tab.
Name
Port column
Admin Speed column
Description
The uplink port ID.
The data transfer rate for the port. This can be one of the following:
• 1 Gbps
• 10 Gbps
• 40 Gbps
• 4 x 10 Gbps
• Auto
Link Training column
Indicates if link training is enabled on the port.
154
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Managing Network Adapters
Configuring Network Adapter Properties
Name Description
Admin FEC Mode column
Following Admin Forward Error Correction (FEC) mode options are available for configuration:
• cl91 (available only with 25G and 100G configurations)
• cl74 (available only with 25G configuration)
• Off (available only with 25G and 100G configurations)
Admin FEC Mode is set to cl91 by default.
Note • FEC mode is applicable only for 25G and 100G link speed. On the
14xx adapters, the Operating FEC mode on the adapter and the switch must match in order to achieve link between devices.
• In order to achieve a successful BER the Operating FEC value needs to meet or exceed the minimum FEC requirement for the transceiver or cable PID in use.
The minimum FEC requirement is dependent on the link speed and specific PID.
Note For 25G refer Cisco 25GBASE SFP28 Modules Data Sheet .
For 25G:
PID
SFP-25G-SR-S
SFP-10/25G-CSR-S
SFP-H25G-CU1M
SFP-H25G-CU2M
SFP-H25G-CU3M
SFP-H25G-CU4M/5M
Min. FEC Optional Higher
FEC
NA cl91 (RS-FEC)
Off - 30M/50M on
OM3/4 cl74 (FC-FEC,
Base-R FEC) (at
25G) cl91 (RS-FEC) cl74 - 70M/100M on
OM3/4 cl91 (RS-FEC) cl91 - 300M/400M on OM3/4
NA
Off cl74 (FC-FEC,
Base-R FEC) cl74 (FC-FEC,
Base-R FEC) cl91 (RS-FEC) cl91 (RS-FEC) cl91 (RS-FEC) cl74 (FC-FEC,
Base-R FEC)
NA cl91 (RS-FEC)
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
155
Managing Network Adapters
Configuring Network Adapter Properties
Name
Operating FEC
Mode column
MAC Address column
Description
SFP-25G-AOC1M
SFP-25G-AOC2M
SFP-25G-AOC3M
SFP-25G-AOC5M
SFP-25G-AOC7M
SFP-25G-AOC10M
For 100G:
All PIDs with the following exceptions require cl91 (RS-FEC):
• QSFP-40/100-SRBD at 100G requires Operating FEC Off
• QSFP-100G-LR4-S requires Operational FEC Off
For these two PIDs the Operating FEC is forced to Off regardless of the Admin FEC value.
For the 100G cables with the QSFP connector to the Nexus Switch and the SFP28 connector to VIC 14XX 25G adapters:
PID Min. FEC Optional Higher
FEC
QSFP-4SFP25G-CU1M/2M Off
QSFP-4SFP25G-CU3M cl74 (FC-FEC,
Base-R FEC) cl74 (FC-FEC,
Base-R FEC) cl91 (RS-FEC) cl91 (RS-FEC)
For 14xx adapters the Operating FEC Mode is set to the Admin FEC Mode value.
The only exceptions are QSFP-40/100-SRBD and QSFP-100G-LR4-S as described in Admin FEC Mode .
Note • For 25G interfaces on Nexus NXOS Switches with Admin FEC value set to Auto , the default value for Operating FEC is cl74 (FC-FEC).
• For 100G interfaces on Nexus Switches with the Admin FEC value set to Auto , the default value for Operating FEC is cl91 (RS-FEC).
The exceptions are QSFP-40/100-SRBD and QSFP-100G-LR4-S. The
Operating FEC is forced to Off , regardless of the Admin FEC value.
Refer to the Admin FEC Mode description for a successful connection with 14xx adapter.
The MAC address of the uplink port.
156
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Managing Network Adapters
Configuring Network Adapter Properties
Name
Link State column
Description
The current operational state of the uplink port. This can be one of the following:
• Fault
• Link Up
• Link Down
• SFP ID Error
• SFP Not Installed
• SFP Security Check Failed
• Unsupported SFP
Encap column The mode in which adapter operates. This can be one of the following:
• CE —Classical Ethernet mode.
• NIV —Network Interface Virtualization mode.
Operating Speed column
The operating rate for the port. This can be one of the following:
• 1 Gbps
• 10 Gbps
• 40 Gbps
• 4 x 10 Gbps
• Auto
• 100 Gbps
Connector Present column
Indicated whether or not the connector is present. This can be one of the following:
• Yes —Connector is present.
• No —Connector not present.
Note This option is only available for some adapter cards.
Connector
Supported column
Indicates whether or not the connector is supported by Cisco. This can be one of the following:
• Yes —The connector is supported by Cisco.
• No —The connector is not supported by Cisco.
If the connector is not supported then the link will not be up.
Note This option is only available for some adapter cards.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
157
Managing vHBAs
Managing Network Adapters
Name
Connector Type column
Description
The type of the connector.
Note This option is only available for some adapter cards.
Connector Vendor column
The vendor for the connector.
Note This option is only available for some adapter cards.
Connector Part
Number column
The part number of the connector.
Note This option is only available for some adapter cards.
Connector Part
Revision column
The part revision number of the connector.
Note This option is only available for some adapter cards.
Managing vHBAs
Guidelines for Managing vHBAs
When managing vHBAs, consider the following guidelines and restrictions:
• The Cisco UCS Virtual Interface Cards provide two vHBAs and two vNICs by default. You can create up to 14 additional vHBAs or vNICs on these adapter cards.
The Cisco UCS 1455 and 1457 Virtual Interface Cards, in non-port channel mode, provide four vHBAs and four vNICs by default. You can create up to 10 additional vHBAs or vNICs on these adapter cards in VNTAG mode.
Note If VNTAG mode is enabled for the adapter, you must assign a channel number to a vHBA when you create it.
• When using the Cisco UCS Virtual Interface Cards in an FCoE application, you must associate the vHBA with the FCoE VLAN. Follow the instructions in the Modifying vHBA Properties section to assign the
VLAN.
• After making configuration changes, you must reboot the host for settings to take effect.
158
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Managing Network Adapters
Viewing vHBA Properties
Viewing vHBA Properties
Procedure
Step 1
Step 2
Step 3
Step 4
Step 5
In the Navigation pane, click the Networking menu.
In the Networking pane, select the Adapter Card that you want to view.
In the Adapter Card area, click the vHBAs tab.
In the vHBAs pane, click fc0 or fc1 .
In the General area of vHBA Properties, review the information in the following fields:
Name
Name field
Description
The name of the virtual HBA.
This name cannot be changed after the vHBA has been created.
Initiator WWNN field The WWNN associated with the vHBA.
To let the system generate the WWNN, select AUTO . To specify a
WWNN, click the second radio button and enter the WWNN in the corresponding field.
Initiator WWPN field
FC SAN Boot check box
Persistent LUN Binding check box
Uplink Port drop-down list
The WWPN associated with the vHBA.
To let the system generate the WWPN, select AUTO . To specify a
WWPN, click the second radio button and enter the WWPN in the corresponding field.
If checked, the vHBA can be used to perform a SAN boot.
If checked, any LUN ID associations are retained in memory until they are manually cleared.
The uplink port associated with the vHBA.
Note This value cannot be changed for the system-defined vHBAs fc0 and fc1.
MAC Address field
Default VLAN
PCI Order field field
The MAC address associated with the vHBA.
To let the system generate the MAC address, select AUTO . To specify an address, click the second radio button and enter the MAC address in the corresponding field.
If there is no default VLAN for this vHBA, click NONE . Otherwise, click the second radio button and enter a VLAN ID between 1 and 4094 in the field.
The order in which this vHBA will be used.
To let the system set the order, select ANY . To specify an order, select the second radio button and enter an integer between 0 and 17.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
159
Managing Network Adapters
Viewing vHBA Properties
Name vHBA Type drop-down list
Class of Service
Rate Limit
EDTOV
RATOV field field field field
Max Data Field Size field
Description
Note This option is available only with 14xx series adapters.
The vHBA type used in this policy. vHBAs supporting FC and
FC-NVMe can now be created on the same adapter. The vHBA type used in this policy can be one of the following:
• fc-initiator—Legacy SCSI FC vHBA initiator
• fc-target—vHBA that supports SCSI FC target functionality
Note This option is available as a Tech Preview.
• fc-nvme-initiator—vHBA that is an FC NVME initiator, which discovers FC NVME targets and connects to them.
• fc-nvme-target—vHBA that acts as an FC NVME target and provides connectivity to the NVME storage.
The CoS for the vHBA.
Select an integer between 0 and 6, with 0 being lowest priority and 6 being the highest priority.
Note This option cannot be used in VNTAG mode.
The data rate limit for traffic on this vHBA, in Mbps.
If you want this vHBA to have an unlimited data rate, select OFF .
Otherwise, click the second radio button and enter an integer between
1 and 10,000.
Note This option cannot be used in VNTAG mode.
The error detect timeout value (EDTOV), which is the number of milliseconds to wait before the system assumes that an error has occurred.
Enter an integer between 1,000 and 100,000. The default is 2,000 milliseconds.
The resource allocation timeout value (RATOV), which is the number of milliseconds to wait before the system assumes that a resource cannot be properly allocated.
Enter an integer between 5,000 and 100,000. The default is 10,000 milliseconds.
The maximum size of the Fibre Channel frame payload bytes that the vHBA supports.
Enter an integer between 256 and 2112.
160
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Managing Network Adapters
Viewing vHBA Properties
Step 6
Step 7
Name
Channel Number
PCI Link
Port Profile field drop-down list
Description
The channel number that will be assigned to this vHBA.
Enter an integer between 1 and 1,000.
Note VNTAG mode is required for this option.
It is read-only field.
The port profile that should be associated with the vHBA, if any.
This field displays the port profiles defined on the switch to which this server is connected.
Note VNTAG mode is required for this option.
In the Error Recovery area, review the information in the following fields:
Name
FCP Error Recovery check box
Description
If checked, the system uses FCP Sequence Level Error Recovery protocol
(FC-TAPE).
Link Down Timeout field
Port Down I/O Retry Count field The number of times an I/O request to a port is returned because the port is busy before the system decides the port is unavailable.
Enter an integer between 0 and 255.
IO Timeout Retry field
The number of milliseconds the uplink port should be offline before it informs the system that the uplink port is down and fabric connectivity has been lost.
Enter an integer between 0 and 240,000.
Port Down Timeout field
The time period till which the system waits for timeout before retrying.
When a disk does not respond for I/O within the defined timeout period, the driver aborts the pending command, and resends the same I/O after the timer expires.
Enter an integer between 1 and 59.
The number of milliseconds a remote Fibre Channel port should be offline before informing the SCSI upper layer that the port is unavailable.
Enter an integer between 0 and 240,000.
In the Fibre Channel Interrupt area, review the information in the following fields:
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
161
Managing Network Adapters
Viewing vHBA Properties
Step 8
Step 9
Step 10
Name
Interrupt Mode drop-down list
Description
The preferred driver interrupt mode. This can be one of the following:
• MSIx —Message Signaled Interrupts (MSI) with the optional extension. This is the recommended option.
• MSI —MSI only.
• INTx —PCI INTx interrupts.
In the Fibre Channel Port area, review the information in the following fields:
Name
I/O Throttle Count field
Description
The number of I/O operations that can be pending in the vHBA at one time.
Enter an integer between 1 and 1,024.
LUNs per Target field
LUN Queue Depth field
The maximum number of LUNs that the driver will export. This is usually an operating system platform limitation.
Enter an integer between 1 and 1,024.
The number of commands that the HBA can send or receive in a single chunk per LUN. This parameter adjusts the initial queue depth for all
LUNs on the adapter.
Default value is 20 for physical miniports and 250 for virtual miniports.
In the Fibre Channel Port FLOGI area, review the information in the following fields:
Name
FLOGI Retries field
Description
The number of times that the system tries to log in to the fabric after the first failure.
To specify an unlimited number of retries, select the INFINITE radio button. Otherwise select the second radio button and enter an integer into the corresponding field.
FLOGI Timeout field The number of milliseconds that the system waits before it tries to log in again.
Enter an integer between 1,000 and 255,000.
In the Fibre Channel Port PLOGI area, review the information in the following fields:
Name
PLOGI Retries field
Description
The number of times that the system tries to log in to a port after the first failure.
Enter an integer between 0 and 255.
162
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Managing Network Adapters
Viewing vHBA Properties
Step 11
Step 12
Step 13
Step 14
Name
PLOGI Timeout field
Description
The number of milliseconds that the system waits before it tries to log in again.
Enter an integer between 1,000 and 255,000.
In the I/O area, review the information in the following fields:
Name Description
CDB Transmit Queue Count field The number of SCSI I/O queue resources the system should allocate.
For Cisco UCS VIC 14xx series adapters, enter an integer between 1 and 64.
For any other VIC adapter, enter an integer between 1 and 245.
CDB Transmit Queue Ring Size field
The number of descriptors in each SCSI I/O queue.
Enter an integer between 64 and 512.
In the Receive/Transmit Queues area, review the information in the following fields:
Name
FC Work Queue Ring Size field
Description
The number of descriptors in each transmit queue.
Enter an integer between 64 and 128.
FC Receive Queue Ring Size field The number of descriptors in each receive queue.
Enter an integer between 64 and 2048.
In the Boot Table area, review the information in the following fields:
Name
Index column
Description
The unique identifier for the boot target.
Target WWPN column
LUN column
Add Boot Entry button
The World Wide Port Name (WWPN) that corresponds to the location of the boot image.
The LUN ID that corresponds to the location of the boot image.
Opens a dialog box that allows you to specify a new WWPN and LUN
ID.
Edit Boot Entry button
Delete Boot Entry button
Opens a dialog box that allows you to change the WWPN and LUN ID for the selected boot target.
Deletes the selected boot target after you confirm the deletion.
In the Persistent Bindings area, review the information in the following fields:
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
163
Managing Network Adapters
Modifying vHBA Properties
Name
Index column
Target WWPN column
Host WWPN column
Bus ID column
Target ID column
Rebuild Persistent Bindings button
Description
The unique identifier for the binding.
The target World Wide Port Name with which the binding is associated.
The host World Wide Port Name with which the binding is associated.
The bus ID with which the binding is associated.
The target ID on the host system with which the binding is associated.
Clears all unused bindings and resets the ones that are in use.
Modifying vHBA Properties
Procedure
Step 1
Step 2
Step 3
Step 4
Step 5
In the Navigation pane, click the Networking menu.
In the Networking pane, select the Adapter Card that you want to modify.
In the Adapter Card pane, click the vHBAs tab.
In the vHBAs pane, click fc0 or fc1 .
In the General area, update the following fields:
Name
Name field
Description
The name of the virtual HBA.
This name cannot be changed after the vHBA has been created.
Initiator WWNN field
Initiator WWPN
FC SAN Boot check box
Persistent LUN Binding check box field
The WWNN associated with the vHBA.
To let the system generate the WWNN, select AUTO . To specify a
WWNN, click the second radio button and enter the WWNN in the corresponding field.
The WWPN associated with the vHBA.
To let the system generate the WWPN, select AUTO . To specify a
WWPN, click the second radio button and enter the WWPN in the corresponding field.
If checked, the vHBA can be used to perform a SAN boot.
If checked, any LUN ID associations are retained in memory until they are manually cleared.
164
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Managing Network Adapters
Modifying vHBA Properties
Name
Uplink Port drop-down list
MAC Address
Default VLAN
PCI Order vHBA Type drop-down list
Class of Service
Rate Limit field field field field field
Description
The uplink port associated with the vHBA.
Note This value cannot be changed for the system-defined vHBAs fc0 and fc1.
The MAC address associated with the vHBA.
To let the system generate the MAC address, select AUTO . To specify an address, click the second radio button and enter the MAC address in the corresponding field.
If there is no default VLAN for this vHBA, click NONE . Otherwise, click the second radio button and enter a VLAN ID between 1 and 4094 in the field.
The order in which this vHBA will be used.
To let the system set the order, select ANY . To specify an order, select the second radio button and enter an integer between 0 and 17.
Note This option is available only with 14xx series adapters.
The vHBA type used in this policy. vHBAs supporting FC and
FC-NVMe can now be created on the same adapter. The vHBA type used in this policy can be one of the following:
• fc-initiator—Legacy SCSI FC vHBA initiator
• fc-target—vHBA that supports SCSI FC target functionality
Note This option is available as a Tech Preview.
• fc-nvme-initiator—vHBA that is an FC NVME initiator, which discovers FC NVME targets and connects to them.
• fc-nvme-target—vHBA that acts as an FC NVME target and provides connectivity to the NVME storage.
The CoS for the vHBA.
Select an integer between 0 and 6, with 0 being lowest priority and 6 being the highest priority.
Note This option cannot be used in VNTAG mode.
The data rate limit for traffic on this vHBA, in Mbps.
If you want this vHBA to have an unlimited data rate, select OFF .
Otherwise, click the second radio button and enter an integer between
1 and 10,000.
Note This option cannot be used in VNTAG mode.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
165
Managing Network Adapters
Modifying vHBA Properties
Step 6
Name
EDTOV
RATOV
Max Data Field Size
Channel Number
PCI Link field field
Port Profile field field drop-down list
Description
The error detect timeout value (EDTOV), which is the number of milliseconds to wait before the system assumes that an error has occurred.
Enter an integer between 1,000 and 100,000. The default is 2,000 milliseconds.
The resource allocation timeout value (RATOV), which is the number of milliseconds to wait before the system assumes that a resource cannot be properly allocated.
Enter an integer between 5,000 and 100,000. The default is 10,000 milliseconds.
The maximum size of the Fibre Channel frame payload bytes that the vHBA supports.
Enter an integer between 256 and 2112.
The channel number that will be assigned to this vHBA.
Enter an integer between 1 and 1,000.
Note VNTAG mode is required for this option.
It is read-only field.
The port profile that should be associated with the vHBA, if any.
This field displays the port profiles defined on the switch to which this server is connected.
Note VNTAG mode is required for this option.
In the Error Recovery area, update the following fields:
Name
FCP Error Recovery check box
Description
If checked, the system uses FCP Sequence Level Error Recovery protocol
(FC-TAPE).
Link Down Timeout field The number of milliseconds the uplink port should be offline before it informs the system that the uplink port is down and fabric connectivity has been lost.
Enter an integer between 0 and 240,000.
Port Down I/O Retry Count field The number of times an I/O request to a port is returned because the port is busy before the system decides the port is unavailable.
Enter an integer between 0 and 255.
166
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Managing Network Adapters
Modifying vHBA Properties
Step 7
Step 8
Step 9
Name
IO Timeout Retry field
Port Down Timeout field
Description
The time period till which the system waits for timeout before retrying.
When a disk does not respond for I/O within the defined timeout period, the driver aborts the pending command, and resends the same I/O after the timer expires.
Enter an integer between 1 and 59.
The number of milliseconds a remote Fibre Channel port should be offline before informing the SCSI upper layer that the port is unavailable.
Enter an integer between 0 and 240,000.
In the Fibre Channel Interrupt area, update the following fields:
Name
Interrupt Mode drop-down list
Description
The preferred driver interrupt mode. This can be one of the following:
• MSIx —Message Signaled Interrupts (MSI) with the optional extension. This is the recommended option.
• MSI —MSI only.
• INTx —PCI INTx interrupts.
In the Fibre Channel Port area, update the following fields:
Name
I/O Throttle Count field
Description
The number of I/O operations that can be pending in the vHBA at one time.
Enter an integer between 1 and 1,024.
LUNs per Target field
LUN Queue Depth field
The maximum number of LUNs that the driver will export. This is usually an operating system platform limitation.
Enter an integer between 1 and 1,024.
The number of commands that the HBA can send or receive in a single chunk per LUN. This parameter adjusts the initial queue depth for all
LUNs on the adapter.
Default value is 20 for physical miniports and 250 for virtual miniports.
In the Fibre Channel Port FLOGI area, update the following fields:
Name
FLOGI Retries field
Description
The number of times that the system tries to log in to the fabric after the first failure.
To specify an unlimited number of retries, select the INFINITE radio button. Otherwise select the second radio button and enter an integer into the corresponding field.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
167
Managing Network Adapters
Modifying vHBA Properties
Step 10
Step 11
Step 12
Step 13
Step 14
Name
FLOGI Timeout field
Description
The number of milliseconds that the system waits before it tries to log in again.
Enter an integer between 1,000 and 255,000.
In the Fibre Channel Port PLOGI area, update the following fields:
Name
PLOGI Retries field
Description
The number of times that the system tries to log in to a port after the first failure.
Enter an integer between 0 and 255.
PLOGI Timeout field The number of milliseconds that the system waits before it tries to log in again.
Enter an integer between 1,000 and 255,000.
In the SCSI I/O area, update the following fields:
Name Description
CDB Transmit Queue Count field The number of SCSI I/O queue resources the system should allocate.
For Cisco UCS VIC 14xx series adapters, enter an integer between 1 and 64.
For any other VIC adapter, enter an integer between 1 and 245.
CDB Transmit Queue Ring Size field
The number of descriptors in each SCSI I/O queue.
Enter an integer between 64 and 512.
In the Receive/Transmit Queues area, update the following fields:
Name
FC Work Queue Ring Size field
Description
The number of descriptors in each transmit queue.
Enter an integer between 64 and 128.
FC Receive Queue Ring Size field The number of descriptors in each receive queue.
Enter an integer between 64 and 2048.
Click Save Changes .
In the Boot Table area, update the following fields or add a new entry:
Name
Index column
Description
The unique identifier for the boot target.
Target WWPN column The World Wide Port Name (WWPN) that corresponds to the location of the boot image.
168
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Managing Network Adapters
Creating a vHBA
Step 15
Name
LUN column
Add Boot Entry
Edit Boot Entry button button
Description
The LUN ID that corresponds to the location of the boot image.
Opens a dialog box that allows you to specify a new WWPN and LUN
ID.
Opens a dialog box that allows you to change the WWPN and LUN ID for the selected boot target.
Deletes the selected boot target after you confirm the deletion.
Delete Boot Entry button
In the Persistent Bindings area, update the following fields or add a new entry:
Name
Index column
Description
The unique identifier for the binding.
Target WWPN
Host WWPN column column
The target World Wide Port Name with which the binding is associated.
The host World Wide Port Name with which the binding is associated.
The bus ID with which the binding is associated.
Bus ID column
Target ID column
Rebuild Persistent Bindings button
The target ID on the host system with which the binding is associated.
Clears all unused bindings and resets the ones that are in use.
Creating a vHBA
The Cisco UCS Virtual Interface Cards provide two vHBAs and two vNICs by default. You can create up to
14 additional vHBAs or vNICs on these adapter cards.
Cisco UCS 1455 and 1457 Virtual Interface Cards, in non-port channel mode, provide four vHBAs and four vNICs by default. You can create up to 10 additional vHBAs or vNICs on these adapter cards.
Before you begin
Ensure that Enable VNTAG Mode under Adapter Card Properties in the General tab is checked.
Procedure
Step 1
Step 2
Step 3
Step 4
In the Navigation pane, click the Networking menu.
In the Networking pane, select the Adapter Card that you want to modify.
In the Adapter Card pane, click the vHBAs tab.
In the Host Fibre Channel Interfaces area, choose one of these actions:
• To create a vHBA using default configuration settings, click Add vHBA .
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
169
Managing Network Adapters
Deleting a vHBA
Step 5
Step 6
Step 7
• To create a vHBA using the same configuration settings as an existing vHBA, select that vHBA and click Clone vHBA .
The Add vHBA dialog box appears.
In the Add vHBA dialog box, enter a name for the vHBA in the Name entry box.
Configure the new vHBA as described in
Modifying vHBA Properties, on page 164 .
Click Add vHBA .
What to do next
• Reboot the server to create the vHBA.
Deleting a vHBA
Default vHBAs cannot be deleted. You can delete any other vHBAs created using VNTAG mode.
Procedure
Step 1
Step 2
Step 3
Step 4
Step 5
In the Navigation pane, click the Networking menu.
In the Networking pane, select the Adapter Card that you want to modify.
In the Adapter Card pane, click the vHBAs tab.
In the Host Fibre Channel Interfaces area, select a vHBA or vHBAs from the table.
Note You cannot delete either of the two default vHBAs, fc0 or fc1 .
Click Delete vHBAs and click OK to confirm.
What to do next
Reboot the server to delete the vHBA.
vHBA Boot Table
In the vHBA boot table, you can specify up to four LUNs from which the server can boot.
Creating a Boot Table Entry
Procedure
Step 1
Step 2
Step 3
In the Navigation pane, click the Networking menu.
In the Networking pane, select the Adapter Card that you want to modify.
In the Adapter Card pane, click the vHBAs tab.
170
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Managing Network Adapters
Deleting a Boot Table Entry
Step 4
Step 5
Step 6
Step 7
Select a vHBA from the list of available vHBAs under vHBAs in the vHBAs tab.
The related vHBA Properties pane is displayed in the right hand side of the window.
Scroll down to view Boot Table at the end of the page.
Click the Add Boot Entry button to open the Add Boot Entry dialog box.
In the Add Boot Entry dialog box, review the following information and perform the actions specified:
Name
Index field
Description
The default value for this field is 0 .
Target WWPN field
LUN ID field
The World Wide Port Name (WWPN) that corresponds to the location of the boot image.
Enter the WWPN in the format hh:hh:hh:hh:hh:hh:hh:hh .
The LUN ID that corresponds to the location of the boot image.
Enter an ID between 0 and 255.
Adds the specified location to the boot table.
Add Boot Entry button
Reset Values button
Cancel button
Clears the values currently entered in the fields.
Closes the dialog box without saving any changes made while the dialog box was open.
Deleting a Boot Table Entry
Procedure
Step 1
Step 2
Step 3
Step 4
Step 5
Step 6
Step 7
In the Navigation pane, click the Networking menu.
In the Networking pane, select the Adapter Card that you want to modify.
In the Adapter Card pane, click the vHBAs tab.
Select a vHBA from the list of available vHBAs under vHBAs in the vHBAs tab.
The related vHBA Properties pane is displayed in the right hand side of the window.
Scroll down to view Boot Table at the end of the page.
In the Boot Table area, click the entry to be deleted.
Click Delete Boot Entry and click OK to confirm.
vHBA Persistent Binding
Persistent binding ensures that the system-assigned mapping of Fibre Channel targets is maintained after a reboot.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
171
Managing Network Adapters
Viewing Persistent Bindings
Viewing Persistent Bindings
Procedure
Step 1
Step 2
Step 3
Step 4
Step 5
In the Navigation pane, click the Networking menu.
In the Networking pane, select the Adapter Card that you want to modify.
In the Adapter Card pane, click the vHBAs tab.
In the vHBAs pane, click fc0 or fc1 .
In the Persistent Bindings area, review the following information:
Name
Index column
Description
The unique identifier for the binding.
Target WWPN
Host WWPN
Bus ID column column column
Target ID column
Rebuild Persistent Bindings button
The target World Wide Port Name with which the binding is associated.
The host World Wide Port Name with which the binding is associated.
The bus ID with which the binding is associated.
The target ID on the host system with which the binding is associated.
Clears all unused bindings and resets the ones that are in use.
Rebuilding Persistent Bindings
Procedure
Step 1
Step 2
Step 3
Step 4
Step 5
Step 6
Step 7
In the Navigation pane, click the Networking menu.
In the Networking pane, select the Adapter Card that you want to modify.
In the Adapter Card pane, click the vHBAs tab.
In the vHBAs pane, click fc0 or fc1 .
Scroll down to the Persistent Bindings area.
Click the Rebuild Persistent Bindings button.
Click OK to confirm.
172
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Managing Network Adapters
Managing vNICs
Managing vNICs
Guidelines for Managing vNICs
When managing vNICs, consider the following guidelines and restrictions:
• The Cisco UCS Virtual Interface Cards provide two vHBAs and two vNICs by default. You can create up to 14 additional vHBAs or vNICs on these adapter cards.
Additional vHBAs can be created using VNTAG mode.
The Cisco UCS 1455 and 1457 Virtual Interface Cards, in non-port channel mode, provide four vHBAs and four vNICs by default. You can create up to 10 additional vHBAs or vNICs on these adapter cards.
Viewing vNIC Properties
Procedure
Step 1
Step 2
Step 3
Step 4
Step 5
Note If VNTAG mode is enabled for the adapter, you must assign a channel number to a vNIC when you create it.
• After making configuration changes, you must reboot the host for settings to take effect.
In the Navigation pane, click the Networking menu.
In the Networking pane, select the Adapter Card that you want to view.
In the Adapter Card pane, click the vNICs tab.
In the vNICs pane, click eth0 or eth1 .
In the General area under vNIC Properties area, review the following fields:
General Area
Name
Name field
Description
The name for the virtual NIC.
This name cannot be changed after the vNIC has been created.
CDN field The Consistent Device Name (CDN) that you can assign to the ethernet vNICs on the VIC cards. Assigning a specific CDN to a device helps in identifying it on the host OS.
Note This feature works only when the CDN Support for VIC token is enabled in the BIOS.
MTU field The maximum transmission unit, or packet size, that this vNIC accepts.
Enter an integer between 1500 and 9000.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
173
Managing Network Adapters
Viewing vNIC Properties
Name
Uplink Port drop-down list
MAC Address field
Class of Service
Trust Host CoS
PCI Order field
Default VLAN field check box radio button
VLAN Mode drop-down list
Description
The uplink port associated with this vNIC. All traffic for this vNIC goes through this uplink port.
The MAC address associated with the vNIC.
To let the adapter select an available MAC address from its internal pool, select Auto . To specify an address, click the second radio button and enter the MAC address in the corresponding field.
The class of service to associate with traffic from this vNIC.
Select an integer between 0 and 6, with 0 being lowest priority and 6 being the highest priority.
Note This option cannot be used in VNTAG mode.
Check this box if you want the vNIC to use the class of service provided by the host operating system.
The order in which this vNIC will be used.
To specify an order, enter an integer within the displayed range.
If there is no default VLAN for this vNIC, select NONE . Otherwise, select the second radio button and enter a VLAN ID between 1 and 4094 in the field.
Note This option cannot be used in VNTAG mode.
If you want to use VLAN trunking, select TRUNK . Otherwise, select
ACCESS .
Note This option cannot be used in VNTAG mode.
174
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Managing Network Adapters
Viewing vNIC Properties
Name
Rate Limit radio button
Channel Number
PCI Link field field
Enable NVGRE check box
Description
If you want this vNIC to have an unlimited data rate, select OFF.
Otherwise, click the second radio button and enter a rate limit in the associated field.
Enter an integer between 1 and 10,000 Mbps.
For VIC 13xx controllers, you can enter an integer between 1 and 40,000
Mbps.
For VIC 1455 and 1457 controllers:
• If the adapter is connected to 25 Gbps link on a Switch, then you can enter an integer between 1 to 25,000 Mbps for the Rate Limit field.
• If the adapter is connected to 10 Gbps link on a Switch, then you can enter an integer between 1 to 10,000 Mbps for the Rate Limit field.
For VIC 1495 and 1497 controllers:
• If the adapter is connected to 40 Gbps link on a switch, then you can enter an integer between 1 to 40,000 Mbps for the Rate Limit field.
• If the adapter is connected to 100 Gbps link on a switch, then you can enter an integer between 1 to 100,000 Mbps for the Rate Limit field.
Note This option cannot be used in VNTAG mode.
Select the channel number that will be assigned to this vNIC.
Note VNTAG mode is required for this option.
The link through which vNICs can be connected. These are the following values:
• 0 - The first cross-edged link where the vNIC is placed.
• 1 - The second cross-edged link where the vNIC is placed.
Note • This option is available only on some Cisco UCS
C-Series servers.
Check this box to enable Network Virtualization using Generic Routing
Encapsulation.
• This option is available only on some Cisco UCS C-Series servers.
• This option is available only on C-Series servers with Cisco VIC
1385 cards.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
175
Managing Network Adapters
Viewing vNIC Properties
Name
Enable VXLAN
Geneve Offload check box check box
Advanced Filter check box
Description
Check this box to enable Virtual Extensible LAN.
• This option is available only on some Cisco UCS C-Series servers.
• This option is available only on C-Series servers with Cisco VIC
1385 and VIC 14xx cards.
Beginning with release 4.1(2a), Cisco IMC supports Generic Network
Virtualization Encapsulation (Geneve) Offload feature with Cisco VIC
14xx series adapters in ESX 7.0 (NSX-T 3.0) and ESX 6.7U3(NSX-T
2.5) OS.
Geneve is a tunnel encapsulation functionality for network traffic . Check this box if you want to enable Geneve Offload encapsulation in Cisco
VIC 14xx series adapters.
Un-check this box to disable Geneve Offload, in order to prevent non-encapsulated UDP packets whose destination port numbers match with the Geneve destination port from being treated as tunneled packets.
If you enable Geneve Offload feature, then Cisco recommends the following settings:
• Transmit Queue Count—1
• Transmit Queue Ring Size—4096
• Receive Queue Count—8
• Receive Queue Ring Size—4096
• Completion Queue Count—9
• Interrupt Count—11
Note You cannot enable the following when Geneve Offload is enabled:
• RDMA on the same vNIC
• usNIC on the same vNIC
• Non-Port Channel Mode on Cisco VIC 145x adapters
• aRFS
• Advanced Filters
• NetQueue
Outer IPV6 is not supported with GENEVE Offload feature.
Downgrade Limitation—If Geneve Offload is enabled, you cannot downgrade to any release earlier than 4.1(2a).
Check this box to enable advanced filter options in vNICs.
176
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Managing Network Adapters
Viewing vNIC Properties
Step 6
Name
Port Profile drop-down list
Description
Select the port profile that should be associated with the vNIC.
This field displays the port profiles defined on the switch to which this server is connected.
Note VNTAG mode is required for this option.
Enable PXE Boot check box
Enable VMQ check box
Check this box if the vNIC can be used to perform a PXE boot.
Check this box to enable Virtual Machine Queue (VMQ).
Enable Multi Queue check box Check this box to enable the Multi Queue option on vNICs. When enabled multi queue vNICs will be available to the host. By default this is disabled.
Note • Multi queue is supported only on C-Series servers with
14xx adapters.
• VMQ must be in enabled state to enable this option.
• When you enable this option on one of the vNICs, configuring only VMQ (without choosing multi-queue) on other vNICs is not supported.
• When this option is enabled usNIC configuration will be disabled.
No. of Sub vNICs
Enable aRFS field check box
Enable Uplink Failover check box
Number of sub vNICs available to the host when the multi queue option is enabled.
Check this box to enable Accelerated Receive Flow steering (aRFS).
This option is available only on some Cisco UCS C-Series servers.
Check this box if traffic on this vNIC should fail over to the secondary interface if there are communication problems.
Note VNTAG mode is required for this option.
Failback Timeout field After a vNIC has started using its secondary interface, this setting controls how long the primary interface must be available before the system resumes using the primary interface for the vNIC.
Enter a number of seconds between 0 and 600.
Note VNTAG mode is required for this option.
In the Ethernet Interrupt area, review the information in the following fields:
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
177
Managing Network Adapters
Viewing vNIC Properties
Step 7
Step 8
Step 9
Name
Interrupt Count field
Interrupt Mode drop-down list
Description
The number of interrupt resources to allocate. In general, this value should be equal to the number of completion queue resources.
Enter an integer between 1 and 1024.
The preferred driver interrupt mode. This can be one of the following:
• MSI-X —Message Signaled Interrupts (MSI) with the optional extension. This is the recommended option.
• MSI —MSI only.
• INTx —PCI INTx interrupts.
Coalescing Time field
Coalescing Type drop-down list
The time to wait between interrupts or the idle period that must be encountered before an interrupt is sent.
Enter an integer between 1 and 65535. To turn off interrupt coalescing, enter 0 (zero) in this field.
This can be one of the following:
• MIN —The system waits for the time specified in the Coalescing
Time field before sending another interrupt event.
• IDLE —The system does not send an interrupt until there is a period of no activity lasting as least as long as the time specified in the
Coalescing Time field.
In the Ethernet Receive Queue area, review the information in the following fields:
Name
Count field
Description
The number of receive queue resources to allocate.
Enter an integer between 1 and 256.
Ring Size field The number of descriptors in each receive queue.
Enter an integer between 64 and 4096.
In the Ethernet Transmit Queue area, review the information in the following fields:
Name
Count field
Description
The number of transmit queue resources to allocate.
Enter an integer between 1 and 256.
Ring Size field The number of descriptors in each transmit queue.
Enter an integer between 64 and 4096.
In the Completion Queue area, review the information in the following fields:
178
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Managing Network Adapters
Viewing vNIC Properties
Step 10
Step 11
Name
Count field
Ring Size
Description
The number of completion queue resources to allocate. In general, the number of completion queue resources you should allocate is equal to the number of transmit queue resources plus the number of receive queue resources.
Enter an integer between 1 and 512.
The number of descriptors in each completion queue.
This value cannot be changed.
In the Multi Queue area, review the information in the following fields:
Name
Receive Queue Count field
Description
The number of receive queue resources to allocate.
Enter an integer between 1 and 1000.
Transmit Queue Count field The number of transmit queue resources to allocate.
Enter an integer between 1 and 1000.
Completion Queue Count field The number of completion queue resources to allocate.
Enter an integer between 1 and 2000.
In the RoCE Properties area, review the information in the following fields:
Name
RoCE checkbox
Description
Check the check box to change the RoCE Properties.
Queue Pairs field
Memory Regions field
The number of queue pairs per adapter. Enter an integer between 1 and
2048.
We recommend that this number be an integer power of 2. The recommended value for queue pairs per vNIC is 2048.
The number of memory regions per adapter. Enter an integer between
1 and 524288. We recommend that this number be an integer power of
2. The recommended value is 131072.
The number of memory regions supported should be enough to meet application requirements as the regions are primarily used to send operation channel semantics.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
179
Managing Network Adapters
Viewing vNIC Properties
Step 12
Step 13
Name
Resource Groups field
Class of Service drop-down list
Description
The number of resource groups per adapter. Enter an integer between
1 and 128. We recommend that this number be an integer power of 2 greater than or equal to the number of CPU cores on the system for optimum performance.
The resource group defines the total number of hardware resources such as WQ, RQ, CQ, and interrupts required to support the RDMA functionality, and is based on the total number of processor cores available with the host. The host chooses to dedicate a particular resource group to a core to maximize performance and get a better non-uniform memory access.
NO Drop QOS COS to be specified. This same value should be configured at the up link switch. Default No Drop QOS COS is 5.
Note This option is available only on some adapters.
In the TCP Offload area, review the information in the following fields:
Name Description
Enable Large Receive check box If checked, the hardware reassembles all segmented packets before sending them to the CPU. This option may reduce CPU utilization and increase inbound throughput.
If cleared, the CPU processes all large packets.
Enable TCP Rx Offload
Checksum Validation check box
If checked, the CPU sends all packet checksums to the hardware for validation. This option may reduce CPU overhead.
If cleared, the CPU validates all packet checksums.
Enable TCP Segmentation
Offload check box
If checked, the CPU sends large TCP packets to the hardware to be segmented. This option may reduce CPU overhead and increase throughput rate.
If cleared, the CPU segments large packets.
Note This option is also known as Large Send Offload (LSO).
Enable TCP Tx Offload
Checksum Generation check box
If checked, the CPU sends all packets to the hardware so that the checksum can be calculated. This option may reduce CPU overhead.
If cleared, the CPU calculates all packet checksums.
In the Receive Side Scaling area, review the information in the following fields:
180
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Managing Network Adapters
Modifying vNIC Properties
Name Description
Enable TCP Receive Side Scaling check box
Receive Side Scaling (RSS) distributes network receive processing across multiple CPUs in multiprocessor systems.
If checked, network receive processing is shared across processors whenever possible.
If cleared, network receive processing is always handled by a single processor even if additional processors are available.
Enable IPv4 RSS check box If checked, RSS is enabled on IPv4 networks.
Enable TCP-IPv4 RSS check box If checked, RSS is enabled for TCP transmissions across IPv4 networks.
Enable IPv6 RSS check box If checked, RSS is enabled on IPv6 networks.
Enable TCP-IPv6 RSS check box If checked, RSS is enabled for TCP transmissions across IPv6 networks.
Enable IPv6 Extension RSS check box
If checked, RSS is enabled for IPv6 extensions.
Enable TCP-IPv6 Extension RSS check box
If checked, RSS is enabled for TCP transmissions across IPv6 networks.
What to do next
Reboot the server to create the vHBA.
Modifying vNIC Properties
Procedure
Step 1
Step 2
Step 3
Step 4
Step 5
In the Navigation pane, click the Networking menu.
In the Networking pane, select the Adapter Card that you want to modify.
In the Adapter Card pane, click the vNICs tab.
In the vNICs pane, click eth0 or eth1 .
In the General area under vNIC Properties in the vNICs pane, update the following fields:
Name
Name field
Description
The name for the virtual NIC.
This name cannot be changed after the vNIC has been created.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
181
Managing Network Adapters
Modifying vNIC Properties
Name
CDN
MTU field field
Uplink Port drop-down list
MAC Address field
Class of Service
Trust Host CoS
PCI Order field
Default VLAN field check box radio button
VLAN Mode drop-down list
Description
The Consistent Device Name (CDN) that you can assign to the ethernet vNICs on the VIC cards. Assigning a specific CDN to a device helps in identifying it on the host OS.
Note This feature works only when the CDN Support for VIC token is enabled in the BIOS.
The maximum transmission unit, or packet size, that this vNIC accepts.
Enter an integer between 1500 and 9000.
The uplink port associated with this vNIC. All traffic for this vNIC goes through this uplink port.
The MAC address associated with the vNIC.
To let the adapter select an available MAC address from its internal pool, select Auto . To specify an address, click the second radio button and enter the MAC address in the corresponding field.
The class of service to associate with traffic from this vNIC.
Select an integer between 0 and 6, with 0 being lowest priority and 6 being the highest priority.
Note This option cannot be used in VNTAG mode.
Check this box if you want the vNIC to use the class of service provided by the host operating system.
The order in which this vNIC will be used.
To specify an order, enter an integer within the displayed range.
If there is no default VLAN for this vNIC, select NONE . Otherwise, select the second radio button and enter a VLAN ID between 1 and 4094 in the field.
Note This option cannot be used in VNTAG mode.
If you want to use VLAN trunking, select TRUNK . Otherwise, select
ACCESS .
Note This option cannot be used in VNTAG mode.
182
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Managing Network Adapters
Modifying vNIC Properties
Name
Rate Limit radio button
Channel Number
PCI Link field field
Enable NVGRE check box
Description
If you want this vNIC to have an unlimited data rate, select OFF.
Otherwise, click the second radio button and enter a rate limit in the associated field.
Enter an integer between 1 and 10,000 Mbps.
For VIC 13xx controllers, you can enter an integer between 1 and 40,000
Mbps.
For VIC 1455 and 1457 controllers:
• If the adapter is connected to 25 Gbps link on a Switch, then you can enter an integer between 1 to 25,000 Mbps for the Rate Limit field.
• If the adapter is connected to 10 Gbps link on a Switch, then you can enter an integer between 1 to 10,000 Mbps for the Rate Limit field.
For VIC 1495 and 1497 controllers:
• If the adapter is connected to 40 Gbps link on a switch, then you can enter an integer between 1 to 40,000 Mbps for the Rate Limit field.
• If the adapter is connected to 100 Gbps link on a switch, then you can enter an integer between 1 to 100,000 Mbps for the Rate Limit field.
Note This option cannot be used in VNTAG mode.
Select the channel number that will be assigned to this vNIC.
Note VNTAG mode is required for this option.
The link through which vNICs can be connected. These are the following values:
• 0 - The first cross-edged link where the vNIC is placed.
• 1 - The second cross-edged link where the vNIC is placed.
Note • This option is available only on some Cisco UCS
C-Series servers.
Check this box to enable Network Virtualization using Generic Routing
Encapsulation.
• This option is available only on some Cisco UCS C-Series servers.
• This option is available only on C-Series servers with Cisco VIC
1385 cards.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
183
Managing Network Adapters
Modifying vNIC Properties
Name
Enable VXLAN
Geneve Offload check box check box
Advanced Filter check box
Description
Check this box to enable Virtual Extensible LAN.
• This option is available only on some Cisco UCS C-Series servers.
• This option is available only on C-Series servers with Cisco VIC
1385 and VIC 14xx cards.
Beginning with release 4.1(2a), Cisco IMC supports Generic Network
Virtualization Encapsulation (Geneve) Offload feature with Cisco VIC
14xx series adapters in ESX 7.0 (NSX-T 3.0) and ESX 6.7U3(NSX-T
2.5) OS.
Geneve is a tunnel encapsulation functionality for network traffic . Check this box if you want to enable Geneve Offload encapsulation in Cisco
VIC 14xx series adapters.
Un-check this box to disable Geneve Offload, in order to prevent non-encapsulated UDP packets whose destination port numbers match with the Geneve destination port from being treated as tunneled packets.
If you enable Geneve Offload feature, then Cisco recommends the following settings:
• Transmit Queue Count—1
• Transmit Queue Ring Size—4096
• Receive Queue Count—8
• Receive Queue Ring Size—4096
• Completion Queue Count—9
• Interrupt Count—11
Note You cannot enable the following when Geneve Offload is enabled:
• RDMA on the same vNIC
• usNIC on the same vNIC
• Non-Port Channel Mode on Cisco VIC 145x adapters
• aRFS
• Advanced Filters
• NetQueue
Outer IPV6 is not supported with GENEVE Offload feature.
Downgrade Limitation—If Geneve Offload is enabled, you cannot downgrade to any release earlier than 4.1(2a).
Check this box to enable advanced filter options in vNICs.
184
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Managing Network Adapters
Modifying vNIC Properties
Step 6
Name
Port Profile drop-down list
Description
Select the port profile that should be associated with the vNIC.
This field displays the port profiles defined on the switch to which this server is connected.
Note VNTAG mode is required for this option.
Enable PXE Boot check box
Enable VMQ check box
Check this box if the vNIC can be used to perform a PXE boot.
Check this box to enable Virtual Machine Queue (VMQ).
Enable Multi Queue check box Check this box to enable the Multi Queue option on vNICs. When enabled multi queue vNICs will be available to the host. By default this is disabled.
Note • Multi queue is supported only on C-Series servers with
14xx adapters.
• VMQ must be in enabled state to enable this option.
• When you enable this option on one of the vNICs, configuring only VMQ (without choosing multi-queue) on other vNICs is not supported.
• When this option is enabled usNIC configuration will be disabled.
No. of Sub vNICs
Enable aRFS field check box
Enable Uplink Failover check box
Number of sub vNICs available to the host when the multi queue option is enabled.
Check this box to enable Accelerated Receive Flow steering (aRFS).
This option is available only on some Cisco UCS C-Series servers.
Check this box if traffic on this vNIC should fail over to the secondary interface if there are communication problems.
Note VNTAG mode is required for this option.
Failback Timeout field After a vNIC has started using its secondary interface, this setting controls how long the primary interface must be available before the system resumes using the primary interface for the vNIC.
Enter a number of seconds between 0 and 600.
Note VNTAG mode is required for this option.
In the Ethernet Interrupt area, update the following fields:
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
185
Managing Network Adapters
Modifying vNIC Properties
Step 7
Step 8
Step 9
Name
Interrupt Count
Coalescing Time field field
Coalescing Type drop-down list
Description
The number of interrupt resources to allocate. In general, this value should be equal to the number of completion queue resources.
Enter an integer between 1 and 1024.
The time to wait between interrupts or the idle period that must be encountered before an interrupt is sent.
Enter an integer between 1 and 65535. To turn off interrupt coalescing, enter 0 (zero) in this field.
This can be one of the following:
• MIN —The system waits for the time specified in the Coalescing
Time field before sending another interrupt event.
• IDLE —The system does not send an interrupt until there is a period of no activity lasting as least as long as the time specified in the
Coalescing Time field.
Interrupt Mode drop-down list The preferred driver interrupt mode. This can be one of the following:
• MSI-X —Message Signaled Interrupts (MSI) with the optional extension. This is the recommended option.
• MSI —MSI only.
• INTx —PCI INTx interrupts.
In the Ethernet Receive Queue area, update the following fields:
Name
Count field
Description
The number of receive queue resources to allocate.
Enter an integer between 1 and 256.
Ring Size field The number of descriptors in each receive queue.
Enter an integer between 64 and 4096.
In the Ethernet Transmit Queue area, update the following fields:
Name
Count field
Description
The number of transmit queue resources to allocate.
Enter an integer between 1 and 256.
Ring Size field The number of descriptors in each transmit queue.
Enter an integer between 64 and 4096.
In the Completion Queue area, update the following fields:
186
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Managing Network Adapters
Modifying vNIC Properties
Step 10
Step 11
Name
Count field
Ring Size
Description
The number of completion queue resources to allocate. In general, the number of completion queue resources you should allocate is equal to the number of transmit queue resources plus the number of receive queue resources.
Enter an integer between 1 and 512.
The number of descriptors in each completion queue.
This value cannot be changed.
In the Multi Queue area, update the following details:
Name
Receive Queue Count field
Description
The number of receive queue resources to allocate.
Enter an integer between 1 and 1000.
Transmit Queue Count field The number of transmit queue resources to allocate.
Enter an integer between 1 and 1000.
Completion Queue Count field The number of completion queue resources to allocate. In general, the number of completion queue resources you should allocate is equal to the number of transmit queue resources plus the number of receive queue resources.
Enter an integer between 1 and 2000.
In the RoCE Properties area, update the following fields:
Name
RoCE check box
Description
Check the check box to change the RoCE Properties.
Note If Multi Queue RoCE is enabled, ensure that VMQ RoCE is also enabled.
Queue Pairs field
Memory Regions
Resource Groups
Class of Service field field field
The number of queue pairs per adapter. Enter an integer between 1 and
2048. We recommend that this number be an integer power of 2.
The number of memory regions per adapter. Enter an integer between
1 and 524288. We recommend that this number be an integer power of
2.
The number of resource groups per adapter. Enter an integer between
1 and 128. We recommend that this number be an integer power of 2 greater than or equal to the number of CPU cores on the system for optimum performance.
This field is read-only and is set to 5.
Note This option is available only on some of the adapters.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
187
Managing Network Adapters
Modifying vNIC Properties
Step 12
Step 13
In the TCP Offload area, update the following fields:
Name Description
Enable Large Receive check box If checked, the hardware reassembles all segmented packets before sending them to the CPU. This option may reduce CPU utilization and increase inbound throughput.
If cleared, the CPU processes all large packets.
Enable TCP Segmentation
Offload check box
If checked, the CPU sends large TCP packets to the hardware to be segmented. This option may reduce CPU overhead and increase throughput rate.
If cleared, the CPU segments large packets.
Note This option is also known as Large Send Offload (LSO).
Enable TCP Rx Offload
Checksum Validation check box
If checked, the CPU sends all packet checksums to the hardware for validation. This option may reduce CPU overhead.
If cleared, the CPU validates all packet checksums.
Enable TCP Tx Offload
Checksum Generation check box
If checked, the CPU sends all packets to the hardware so that the checksum can be calculated. This option may reduce CPU overhead.
If cleared, the CPU calculates all packet checksums.
In the Receive Side Scaling area, update the following fields:
Name Description
Enable TCP Receive Side Scaling check box
Receive Side Scaling (RSS) distributes network receive processing across multiple CPUs in multiprocessor systems.
If checked, network receive processing is shared across processors whenever possible.
If cleared, network receive processing is always handled by a single processor even if additional processors are available.
Enable IPv4 RSS check box If checked, RSS is enabled on IPv4 networks.
Enable TCP-IPv4 RSS check box If checked, RSS is enabled for TCP transmissions across IPv4 networks.
Enable IPv6 RSS check box If checked, RSS is enabled on IPv6 networks.
Enable TCP-IPv6 RSS check box If checked, RSS is enabled for TCP transmissions across IPv6 networks.
Enable IPv6 Extension RSS check box
If checked, RSS is enabled for IPv6 extensions.
Enable TCP-IPv6 Extension RSS check box
If checked, RSS is enabled for TCP transmissions across IPv6 networks.
188
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Managing Network Adapters
Creating a vNIC
Step 14 Click Save Changes .
What to do next
Reboot the server to modify the vNIC.
Creating a vNIC
The Cisco UCS Virtual Interface Cards provide two vHBAs and two vNICs by default. You can create up to
14 additional vHBAs or vNICs on these adapter cards.
The Cisco UCS 1455 and 1457 Virtual Interface Cards, in non-port channel mode, provide four vHBAs and four vNICs by default. You can create up to 10 additional vHBAs or vNICs on these adapter cards.
Procedure
Step 1
Step 2
Step 3
Step 4
Step 5
Step 6
Step 7
In the Navigation pane, click the Networking menu.
In the Networking pane, select the Adapter Card that you want to modify.
In the Adapter Card pane, click the vNICs tab.
In the Host Ethernet Interfaces area, choose one of these actions:
• To create a vNIC using default configuration settings, click Add vNIC .
• To create a vNIC using the same configuration settings as an existing vNIC, select that vNIC and click
Clone vNIC .
The Add vNIC dialog box appears.
In the Add vNIC dialog box, enter a name for the vNIC in the Name entry box.
In the Add vNIC dialog box, enter a channel number for the vNIC in the Channel Number entry box.
Note If VNTAG is enabled on the adapter, you must assign a channel number for the vNIC when you create it.
Click Add vNIC .
What to do next
If configuration changes are required, configure the new vNIC as described in
Modifying vNIC Properties, on page 181
.
Deleting a vNIC
Procedure
Step 1 In the Navigation pane, click the Networking menu.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
189
Managing Network Adapters
Configuring iSCSI Boot Capability
Step 2
Step 3
Step 4
Step 5
In the Networking pane, select the Adapter Card that you want to modify.
In the Adapter Card pane, click the vNICs tab.
In the Host Ethernet Interfaces area, select a vNIC from the table.
Note You cannot delete either of the two default vNICs, eth0 or eth1 .
Click Delete vNIC and click OK to confirm.
Configuring iSCSI Boot Capability
Configuring iSCSI Boot Capability for vNICs
To configure the iSCSI boot capability on a vNIC:
• You must log in with admin privileges to perform this task.
• To configure a vNIC to boot a server remotely from an iSCSI storage target, you must enable the PXE boot option on the vNIC.
Note You can configure a maximum of 2 iSCSI vNICs for each host.
Configuring iSCSI Boot Capability on a vNIC
Procedure
Step 1
Step 2
Step 3
Step 4
Step 5
Step 6
In the Navigation pane, click the Networking menu.
In the Networking pane, select the Adapter Card that you want to modify.
In the Adapter Card pane, click the vNICs tab.
In the vNICs pane, click eth0 or eth1 .
Select the iSCSI Boot Properties area.
In the General area, update the following fields:
Name
Name field
Description
The name of the vNIC.
DHCP Network check box Whether DHCP Network is enabled for the vNIC.
If enabled, the initiator network configuration is obtained from the DHCP server.
190
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Managing Network Adapters
Configuring iSCSI Boot Capability on a vNIC
Step 7
Name
DHCP iSCSI
DHCP ID check box field
DHCP Timeout
Link Timeout field field
LUN Busy Retry Count field
Description
Whether DHCP iSCSI is enabled for the vNIC. If enabled and the DHCP
ID is set, the initiator IQN and target information are obtained from the
DHCP server.
Note If DHCP iSCSI is enabled without a DHCP ID, only the target information is obtained.
The vendor identifier string used by the adapter to obtain the initiator
IQN and target information from the DHCP server.
Enter a string up to 64 characters.
The number of seconds to wait before the initiator assumes that the
DHCP server is unavailable.
Enter an integer between 60 and 300 (default: 60 seconds)
The number of seconds to wait before the initiator assumes that the link is unavailable.
Enter an integer between 0 and 255 (default: 15 seconds)
The number of times to retry the connection in case of a failure during iSCSI LUN discovery.
Enter an integer between 0 and 255. The default is 15.
The IP version to use during iSCSI boot.
IP Version field
In the Initiator area, update the following fields:
Name
Name field
Description
A regular expression that defines the name of the iSCSI initiator.
You can enter any alphanumeric string as well as the following special characters:
• . (period)
• : (colon)
• - (dash)
Note The name is in the IQN format.
IP Address field
Subnet Mask field
The IP address of the iSCSI initiator.
The subnet mask for the iSCSI initiator.
Gateway field
Primary DNS field
The default gateway.
The primary DNS server address.
Initiator Priority drop-down list The initiator priority drop-down list.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
191
Managing Network Adapters
Configuring iSCSI Boot Capability on a vNIC
Step 8
Step 9
Name
Secondary DNS
TCP Timeout
CHAP Name
CHAP Secret field field field field
Description
The secondary DNS server address.
The number of seconds to wait before the initiator assumes that TCP is unavailable.
Enter an integer between 0 and 255 (default: 15 seconds)
The Challenge-Handshake Authentication Protocol (CHAP) name of the initiator.
The Challenge-Handshake Authentication Protocol (CHAP) shared secret of the initiator.
In the Primary Target area, update the following fields:
Name
Name field
Description
The name of the primary target in the IQN format.
IP Address
TCP Port field field
The IP address of the target.
The TCP port associated with the target.
The Boot LUN associated with the target.
Boot LUN field
CHAP Name field
CHAP Secret field
The Challenge-Handshake Authentication Protocol (CHAP) name of the initiator.
The Challenge-Handshake Authentication Protocol (CHAP) shared secret of the initiator.
In the Secondary Target area, update the following fields:
Name
Name field
Description
The name of the secondary target in the IQN format.
IP Address
TCP Port field field
Boot LUN field
CHAP Name field
CHAP Secret field
The IP address of the target.
The TCP port associated with the target.
The Boot LUN associated with the target.
The Challenge-Handshake Authentication Protocol (CHAP) name of the initiator.
The Challenge-Handshake Authentication Protocol (CHAP) shared secret of the initiator.
Name
Configure ISCSI button
Unconfigure ISCSI button
Description
Configures iSCSI boot on the selected vNIC.
Removes the configuration from the selected vNIC.
192
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Managing Network Adapters
Removing iSCSI Boot Configuration from a vNIC
Step 10
Name
Reset Values button
Cancel button
Click Save Changes .
Description
Restores the values for the vNIC to the settings that were in effect when this dialog box was first opened.
Closes the dialog box without making any changes.
Removing iSCSI Boot Configuration from a vNIC
Before you begin
You must log in with admin privileges to perform this task.
Procedure
Step 1
Step 2
Step 3
Step 4
Step 5
Step 6
In the Navigation pane, click the Networking menu.
In the Networking pane, select the Adapter Card that you want to modify.
In the Adapter Card pane, click the vNICs tab.
In the vNICs pane, click eth0 or eth1 .
Select the iSCSI Boot Properties area.
Click the Unconfigure ISCSI Boot button at the bottom of the iSCSI Boot Properties area.
What to do next
Reboot the server to remove the iSCSI Boot Configuration.
Managing Cisco usNIC
Overview of Cisco usNIC
The Cisco user-space NIC (Cisco usNIC) feature improves the performance of software applications that run on the Cisco UCS servers in your data center by bypassing the kernel when sending and receiving networking packets. The applications interact directly with a Cisco UCS VIC second generation or later generation adapter, such as the , which improves the networking performance of your high-performance computing cluster. To benefit from Cisco usNIC, your applications must use the Message Passing Interface (MPI) instead of sockets or other communication APIs.
Cisco usNIC offers the following benefits for your MPI applications:
• Provides a low-latency and high-throughput communication transport.
• Employs the standard and application-independent Ethernet protocol.
• Takes advantage of lowlatency forwarding, Unified Fabric, and integrated management support in the following Cisco data center platforms:
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
193
Managing Network Adapters
Viewing and Configuring Cisco usNIC using the Cisco IMC GUI
• Cisco UCS server
• Cisco UCS VIC second generation or later generation adapter
• 10 or 40GbE networks
Standard Ethernet applications use user-space socket libraries, which invoke the networking stack in the Linux kernel. The networking stack then uses the Cisco eNIC driver to communicate with the Cisco VIC hardware.
The following figure shows the contrast between a regular software application and an MPI application that uses Cisco usNIC.
Figure 1: Kernel-Based Network Communication versus Cisco usNIC-Based Communication
Viewing and Configuring Cisco usNIC using the Cisco IMC GUI
Before you begin
You must log in to the Cisco IMC GUI with admin privileges to perform this task. Click Play on this video to watch how to configure Cisco usNIC in Cisco IMC.
Procedure
Step 1 Log into the Cisco IMC GUI.
194
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Managing Network Adapters
Viewing and Configuring Cisco usNIC using the Cisco IMC GUI
Step 2
Step 3
Step 4
Step 5
Step 6
For more information about how to log into Cisco IMC, see Cisco UCS C-Series Servers Integrated Management
Controller GUI Configuration Guide .
In the Navigation pane, click the Networking menu.
In the Networking pane, select the Adapter Card that you want to modify.
In the Adapter Card pane, click the vNICs tab.
In the vNICs pane, click eth0 or eth1 .
In the usNIC area, review and update the following fields.
Name
Name
Description
The name for the vNIC that is the parent of the usNIC.
Note This field is read-only.
usNIC field
Transmit Queue Count
Receive Queue Count
Interrupt Count field field field
Completion Queue Count
Transmit Queue Ring Size
Receive Queue Ring Size field field field
The number of usNICs assigned to the specific vNIC.
Enter an integer between 0 and 225.
To assign additional usNICs to a specified vNIC, enter value higher than the existing value.
To delete usNICs from a specified vNIC, enter value smaller than the existing value.
To delete all the usNICs assigned to a vNIC, enter zero.
The number of transmit queue resources to allocate.
Enter an integer between 1 and 256.
The number of receive queue resources to allocate.
Enter an integer between 1 and 256.
The number of completion queue resources to allocate.
In general, the number of completion queue resources you should allocate is equal to the number of transmit queue resources plus the number of receive queue resources.
Enter an integer between 1 and 512.
The number of descriptors in each transmit queue.
Enter an integer between 64 and 4096.
The number of descriptors in each receive queue.
Enter an integer between 64 and 4096.
The number of interrupt resources to allocate. In general, this value should be equal to the number of completion queue resources.
Enter an integer between 1 and 514.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
195
Managing Network Adapters
Viewing and Configuring Cisco usNIC using the Cisco IMC GUI
Name
Interrupt Coalescing Type drop-down list
Interrupt Coalescing Timer Time
Class of Service
Large Receive field
TCP Segment Offload check box check box
TCP Tx Checksum
TCP Rx Checksum check box check box field
Description
This can be one of the following:
• MIN —The system waits for the time specified in the Coalescing Time field before sending another interrupt event.
• IDLE —The system does not send an interrupt until there is a period of no activity lasting as least as long as the time specified in the
Coalescing Time field.
The time to wait between interrupts or the idle period that must be encountered before an interrupt is sent.
Enter an integer between 1 and 65535. To turn off interrupt coalescing, enter 0 (zero) in this field.
The class of service to associate with traffic from this usNIC.
Select an integer between 0 and 6, with 0 being lowest priority and 6 being the highest priority.
Note This option cannot be used in VNTAG mode.
If checked, the CPU sends large TCP packets to the hardware to be segmented. This option may reduce
CPU overhead and increase throughput rate.
If cleared, the CPU segments large packets.
Note This option is also known as Large Send
Offload (LSO).
If checked, the hardware reassembles all segmented packets before sending them to the CPU. This option may reduce CPU utilization and increase inbound throughput.
If cleared, the CPU processes all large packets.
If checked, the CPU sends all packets to the hardware so that the checksum can be calculated. This option may reduce CPU overhead.
If cleared, the CPU calculates all packet checksums.
If checked, the CPU sends all packet checksums to the hardware for validation. This option may reduce
CPU overhead.
If cleared, the CPU validates all packet checksums.
196
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Managing Network Adapters
Viewing usNIC Properties
Step 7 Click Save Changes .
The changes take effect upon the next server reboot.
Viewing usNIC Properties
Procedure
Step 1
Step 2
Step 3
Step 4
Step 5
In the Navigation pane, click the Networking menu.
In the Networking pane, select the Adapter Card that you want to view.
In the Adapter Card pane, click the vNICs tab.
In the vNICs pane, click eth0 or eth1 .
In the Host Ethernet Interfaces pane's usNIC Properties area, review the information in the following fields:
Name
Name
Description
The name for the vNIC that is the parent of the usNIC.
Note This field is read-only.
usNIC field
Transmit Queue Count
Receive Queue Count field field
Completion Queue Count
Transmit Queue Ring Size field field
The number of usNICs assigned to the specific vNIC.
Enter an integer between 0 and 225.
To assign additional usNICs to a specified vNIC, enter value higher than the existing value.
To delete usNICs from a specified vNIC, enter value smaller than the existing value.
To delete all the usNICs assigned to a vNIC, enter zero.
The number of transmit queue resources to allocate.
Enter an integer between 1 and 256.
The number of receive queue resources to allocate.
Enter an integer between 1 and 256.
The number of completion queue resources to allocate.
In general, the number of completion queue resources you should allocate is equal to the number of transmit queue resources plus the number of receive queue resources.
Enter an integer between 1 and 512.
The number of descriptors in each transmit queue.
Enter an integer between 64 and 4096.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
197
Managing Network Adapters
Viewing usNIC Properties
Name
Receive Queue Ring Size
Interrupt Count field field
Interrupt Coalescing Type drop-down list
Interrupt Coalescing Timer Time
Class of Service
TCP Segment Offload
Large Receive field check box check box field
Description
The number of descriptors in each receive queue.
Enter an integer between 64 and 4096.
The number of interrupt resources to allocate. In general, this value should be equal to the number of completion queue resources.
Enter an integer between 1 and 514.
This can be one of the following:
• MIN —The system waits for the time specified in the Coalescing Time field before sending another interrupt event.
• IDLE —The system does not send an interrupt until there is a period of no activity lasting as least as long as the time specified in the
Coalescing Time field.
The time to wait between interrupts or the idle period that must be encountered before an interrupt is sent.
Enter an integer between 1 and 65535. To turn off interrupt coalescing, enter 0 (zero) in this field.
The class of service to associate with traffic from this usNIC.
Select an integer between 0 and 6, with 0 being lowest priority and 6 being the highest priority.
Note This option cannot be used in VNTAG mode.
If checked, the CPU sends large TCP packets to the hardware to be segmented. This option may reduce
CPU overhead and increase throughput rate.
If cleared, the CPU segments large packets.
Note This option is also known as Large Send
Offload (LSO).
If checked, the hardware reassembles all segmented packets before sending them to the CPU. This option may reduce CPU utilization and increase inbound throughput.
If cleared, the CPU processes all large packets.
198
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Managing Network Adapters
Name
TCP Tx Checksum check box
TCP Rx Checksum check box
Backing Up and Restoring the Adapter Configuration
Description
If checked, the CPU sends all packets to the hardware so that the checksum can be calculated. This option may reduce CPU overhead.
If cleared, the CPU calculates all packet checksums.
If checked, the CPU sends all packet checksums to the hardware for validation. This option may reduce
CPU overhead.
If cleared, the CPU validates all packet checksums.
Backing Up and Restoring the Adapter Configuration
Exporting the Adapter Configuration
The adapter configuration can be exported as an XML file to a remote server which can be one of the following:
• TFTP
• FTP
• SFTP
• SCP
• HTTP
Before you begin
Obtain the remote server IP address.
Procedure
Step 1
Step 2
Step 3
Step 4
Step 5
In the Navigation pane, click the Networking menu.
In the Networking pane, select the Adapter Card that you want to modify.
In the Adapter Card pane, click the General tab.
In the Actions area of the General tab, click Export vNIC .
The Export vNIC dialog box opens.
In the Export Adapter Configuration dialog box, update the following fields:
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
199
Managing Network Adapters
Importing the Adapter Configuration
Step 6
Name
Export To drop-down list
IP Address or Host Name field
Path and Filename
Username
Password field
Description
The remote server type. This can be one of the following:
• TFTP Server
• FTP Server
• SFTP Server
• SCP Server
• HTTP Server
Note If you chose SCP or SFTP as the remote server type while performing this action, a pop-up window is displayed with the message Server (RSA) key fingerprint is <server_finger_print
_ID> Do you wish to continue?
. Click Yes or No depending on the authenticity of the server fingerprint.
The fingerprint is based on the host's public key and helps you to identify or verify the host you are connecting to.
The IPv4 or IPv6 address, or hostname of the server to which the adapter configuration file will be exported. Depending on the setting in the Export to drop-down list, the name of the field may vary.
The path and filename Cisco IMC should use when exporting the file to the remote server.
The username the system should use to log in to the remote server. This field does not apply if the protocol is TFTP or HTTP.
The password for the remote server username. This field does not apply if the protocol is TFTP or HTTP.
Click Export vNIC .
Importing the Adapter Configuration
Procedure
Step 1
Step 2
Step 3
Step 4
Step 5
In the Navigation pane, click the Networking menu.
In the Networking pane, select the Adapter Card that you want to modify.
Select the General tab.
In the Actions area of the General tab, click Import vNIC .
The Import vNIC dialog box is displayed.
In the Import vNIC dialog box, update the following fields:
200
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Managing Network Adapters
Restoring Adapter Defaults
Step 6
Name
Import from drop-down list
Description
The remote server type. This can be one of the following:
• TFTP Server
• FTP Server
• SFTP Server
• SCP Server
• HTTP Server
Note If you chose SCP or SFTP as the remote server type while performing this action, a pop-up window is displayed with the message Server (RSA) key fingerprint is <server_finger_print
_ID> Do you wish to continue?
. Click Yes or No depending on the authenticity of the server fingerprint.
The fingerprint is based on the host's public key and helps you to identify or verify the host you are connecting to.
IP Address or Host Name field
Path and Filename
Username
Password field
The IPv4 or IPv6 address, or hostname of the server on which the adapter configuration file resides. Depending on the setting in the Import from drop-down list, the name of the field may vary.
The path and filename of the configuration file on the remote server.
The username the system should use to log in to the remote server. This field does not apply if the protocol is TFTP or HTTP.
The password for the remote server username. This field does not apply if the protocol is TFTP or HTTP.
Click Import vNIC .
What to do next
Reboot the server to apply the imported configuration.
Restoring Adapter Defaults
Procedure
Step 1
Step 2
Step 3
In the Navigation pane, click the Networking menu.
In the Networking pane, select the Adapter Card that you want to restore to default settings.
Select the General tab.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
201
Managing Network Adapters
Resetting the Adapter
Step 4 In the Actions area of the General tab, click Reset To Defaults and click OK to confirm.
Resetting the Adapter
Procedure
Step 1
Step 2
Step 3
Step 4
In the Navigation pane, click the Networking menu.
In the Networking pane, select the Adapter Card that you want to reset.
Select the General tab.
In the Actions area of the General tab, click Reset and click OK to confirm.
Note Resetting the adapter also resets the host.
202
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
C H A P T E R
12
Managing Storage Adapters
This chapter includes the following sections:
•
Managing Storage Adapters, on page 203
•
Managing the Flexible Flash Controller, on page 231
•
Managing the FlexUtil Controller, on page 240
•
Cisco Boot Optimized M.2 Raid Controller, on page 251
Managing Storage Adapters
Self Encrypting Drives (Full Disk Encryption)
Cisco IMC supports self encrypting drives (SED). A special hardware in the drives encrypts incoming data and decrypts outgoing data in real-time. This feature is also called Full Disk Encryption (FDE).
The data on the drive is encrypted on its way into the drive and decrypted on its way out. However, if you lock the drive, no security key is required to retrieve the data.
When a drive is locked, an encryption key is created and stored internally. All data stored on this drive is encrypted using that key, and stored in encrypted form. Once you store the data in this manner, a security key is required in order to un-encrypt and fetch the data from the drive. Unlocking a drive deletes that encryption key and renders the stored data unusable. This is called a Secure Erase. The FDE comprises a key ID and a security key.
The FDE feature supports the following operations:
• Enable and disable security on a controller
• Create a secure virtual drive
• Secure a non-secure drive group
• Unlock foreign configuration drives
• Enable security on a physical drive (JBOD)
• Clear secure SED drives
• Clear secure foreign configuration
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
203
Managing Storage Adapters
Enabling Controller Security
Scenarios to consider While Configuring Controller Security in a Dual or Multiple Controllers
Environment
Note Dual or Multiple controllers connectivity is available only on some servers.
Controller security can be enabled, disabled, or modified independently. However, local and remote key management applies to all the controllers on the server. Therefore security action involving switching the key management modes must be performed with caution. In a scenario where both controllers are secure, and you decide to move one of the controllers to a different mode, you need to perform the same operation on the other controller as well.
Consider the following two scenarios:
• Scenario 1—Key management is set to remote; both controllers are secure and use remote key management. If you now wish to switch to local key management, switch the key management for each controller and disable remote key management.
• Scenario 2—Key management is set to local; both controllers are secure and use local key management.
If you now wish to switch to remote key management, enable remote key management and switch the key management for each controller.
If you do not modify the controller security method on any one of the controllers, it renders the secure key management in an unsupported configuration state.
Enabling Controller Security
This option is available only on some C-series servers.
Before you begin
You must log in with admin privileges to perform this task.
Procedure
Step 1
Step 2
Step 3
Step 4
In the Navigation pane, click the Storage menu.
In the Storage menu, click the appropriate LSI MegaRAID or HBA controller.
In the Controller Info area, click Enable Drive Security .
In the Enable Drive Security dialog box, update the following fields:
Name
Controller Security field
Description
Indicates that the controller is disabled.
204
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Managing Storage Adapters
Modifying Controller Security
Step 5
Name
Key Management field
Security Key Identifier
Security Key field field
Confirm Security Key field
Suggest button
Click Save .
This enables controller security.
Description
Indicates whether the key is remotely managed or locally managed. This can be one of the following:
• Remote Key Management radio button— Controller security key is configured or managed using the remote KMIP server.
Note If you choose this option, you do not have to specify the existing security key but you have to provide the key
ID and the security key for local management.
• Local Key Management radio button— Controller security is configured locally.
The current key ID.
Security key used to enable controller security. If you wish to change the current security key, enter the new key here.
Note Once you change the security key, a Secure Key Verification pop-up window appears where you need to enter the current security key to verify it.
Re-enter the security key.
Suggests the security key or key ID that can be assigned.
Modifying Controller Security
This option is available only on some C-series servers.
Before you begin
• You must log in with admin privileges to perform this task.
• You must have first enabled controller security to modify it.
Procedure
Step 1
Step 2
Step 3
Step 4
In the Navigation pane, click the Storage menu.
In the Storage menu, click the appropriate LSI MegaRAID or HBA controller.
In the Controller Info area, click Modify Drive Security .
In the Modify Drive Security dialog box, update the following fields:
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
205
Managing Storage Adapters
Disabling Controller Security
Step 5
Name
Controller Security field
Security Key Identifier
Security Key field field
Description
Indicates whether or not controller security is enabled. This can be one of the following:
• Enabled — Controller security is enabled.
• Disabled — Controller security is disabled.
The current key ID.
Security key used to enable controller security. If you wish to change the current security key, enter the new key here.
Note Once you change the security key, a Secure Key Verification pop-up window appears where you need to enter the current security key to verify it.
Confirm Security Key field
Modify Security Key check box
Re-enter the security key.
Note This option appears only for remote key management.
Suggest
Save
Cancel button button button
If you select this option the security key on the KMIP server is modified.
Suggests the security key or key ID that can be assigned.
Saves the data.
Cancels the action.
Click Save .
This modifies the controller security settings.
Disabling Controller Security
This option is available only on some C-series servers.
Before you begin
• You must log in with admin privileges to perform this task.
• You must have first enabled controller security to disable it.
Procedure
Step 1
Step 2
Step 3
Step 4
In the Navigation pane, click the Storage menu.
In the Storage menu, click the appropriate LSI MegaRAID or HBA controller.
In the Controller Info area, click Disable Drive Security .
Click OK in the confirmation pop-up window.
206
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Managing Storage Adapters
Switching Controller Security Between Local and Remote Key Management
This disables controller security.
Switching Controller Security Between Local and Remote Key Management
This task allows you to switch controller security from local management to remote management, and from remote to local management.
Before you begin
You must log in with admin privileges to perform this task.
Procedure
Step 1
Step 2
Step 3
Step 4
Step 5
In the Navigation pane, click the Storage menu.
In the Storage menu, click the appropriate LSI MegaRAID or HBA controller.
In the Controller Info area, to switch the controller security from remote to local management, click Switch to Local Key Management .
Note When you switch from remote to local key management, ensure that you disable KMIP secure key management first.
(Optional) Similarly, if you want to switch the controller security from local to remote management, click
Switch to Remote Key Management .
Click OK to confirm.
Creating Virtual Drive from Unused Physical Drives
Before you begin
You must log in with admin privileges to perform this task.
Procedure
Step 1
Step 2
Step 3
Step 4
In the Navigation pane, click the Storage menu.
In the Storage menu, click the appropriate LSI MegaRAID or HBA controller.
In the Actions area, click Create Virtual Drive from Unused Physical Drives .
The Create Virtual Drive from Unused Physical Drives dialog box displays.
In the Create Virtual Drive from Unused Physical Drives dialog box, select the RAID level for the new virtual drives:
This can be one of the following:
• Raid 0 —Simple striping.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
207
Managing Storage Adapters
Creating Virtual Drive from Unused Physical Drives
Step 5
• Raid 1 —Simple mirroring.
• Raid 5 —Striping with parity.
• Raid 6 —Striping with two parity drives.
• Raid 10 —Spanned mirroring.
• Raid 50 —Spanned striping with parity.
• Raid 60 —Spanned striping with two parity drives.
In the Create Drive Groups area, choose one or more physical drives to include in the group.
Use the >> button to add the drives to the Drive Groups table. Use the << button to remove physical drives from the drive group.
Note • The size of the smallest physical drive in the drive group defines the maximum size used for all the physical drives. To ensure maximum use of space for all physical drives, it is recommended that the size of all the drives in the drive group are similar.
• Cisco IMC manages only RAID controllers and not HBAs attached to the server.
• You must have multiple drive groups available to create virtual drives for certain RAID levels.
While creating drives for these RAID levels, the create drive option is available only if the required number of drives are selected.
Step 6 In the Virtual Drive Properties area, update the following properties:
Name
Virtual Drive Name
Read Policy field drop-down list
Description
The name of the new virtual drive you want to create.
The read-ahead cache mode.
Cache Policy
Strip Size
Write Policy drop-down list drop-down list drop-down list
The cache policy used for buffering reads.
The size of each strip, in KB.
This can be one of the following
• Write Through — Data is written through the cache and to the physical drives. Performance is improved, because subsequent reads of that data can be satisfied from the cache.
• Write Back — Data is stored in the cache, and is only written to the physical drives when space in the cache is needed. Virtual drives requesting this policy fall back to Write Through caching when the BBU cannot guarantee the safety of the cache in the event of a power failure.
• Write Back Bad BBU —With this policy, write caching remains
Write Back even if the battery backup unit is defective or discharged.
208
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Managing Storage Adapters
Creating Virtual Drive from an Existing Drive Group
Name Description
Disk Cache Policy drop-down list This can be one of the following
• Unchanged — The disk cache policy is unchanged.
• Enabled — Allows IO caching on the disk.
• Disabled — Disallows disk caching.
Access Policy drop-down list
Size field
This can be one of the following
• Read Write — Enables host to perform read-write on the VD.
• Read Only — Host can only read from the VD.
• Blocked — Host can neither read nor write to the VD.
The size of the virtual drive you want to create. Enter a value and select one of the following units:
• MB
• GB
• TB
Step 7
Step 8
Step 9
Click the Generate XML API Request button to generate an API request.
Click Close .
Click Create Virtual Drive .
Creating Virtual Drive from an Existing Drive Group
Before you begin
You must log in with admin privileges to perform this task.
Procedure
Step 1
Step 2
Step 3
Step 4
Step 5
In the Navigation pane, click the Storage menu.
In the Storage menu, click the appropriate LSI MegaRAID or HBA controller.
In the Actions area, click Create Virtual Drive from an Existing Virtual Drive Group .
The Create Virtual Drive from an Existing Virtual Drive Group dialog box displays.
In the Create Virtual Drive from an Existing Virtual Drive Group dialog box, select the virtual drive whose drive group you want to use to create a new virtual drive.
In the Virtual Drive Properties area, update the following properties:
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
209
Managing Storage Adapters
Creating Virtual Drive from an Existing Drive Group
Name
Virtual Drive Name
Read Policy
Cache Policy
Strip Size field drop-down list drop-down list drop-down list
Write Policy drop-down list
Description
The name of the new virtual drive you want to create.
The read-ahead cache mode.
The cache policy used for buffering reads.
The size of each strip, in KB.
This can be one of the following
• Write Through — Data is written through the cache and to the physical drives. Performance is improved, because subsequent reads of that data can be satisfied from the cache.
• Write Back — Data is stored in the cache, and is only written to the physical drives when space in the cache is needed. Virtual drives requesting this policy fall back to Write Through caching when the BBU cannot guarantee the safety of the cache in the event of a power failure.
• Write Back Bad BBU —With this policy, write caching remains
Write Back even if the battery backup unit is defective or discharged.
Disk Cache Policy drop-down list This can be one of the following
• Unchanged — The disk cache policy is unchanged.
• Enabled — Allows IO caching on the disk.
• Disabled — Disallows disk caching.
Access Policy drop-down list This can be one of the following
• Read Write — Enables host to perform read-write on the VD.
• Read Only — Host can only read from the VD.
• Blocked — Host can neither read nor write to the VD.
Size field The size of the virtual drive you want to create. Enter a value and select one of the following units:
• MB
• GB
• TB
Step 6
Step 7
Step 8
Click the Generate XML API Request button to generate an API request.
Click Close .
Click Create Virtual Drive .
210
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Managing Storage Adapters
Setting a Virtual Drive to Transport Ready State
Setting a Virtual Drive to Transport Ready State
You can move a virtual drive from one MegaRAID controller to another using the Set Transport Ready feature. This allows all the pending IOs of the virtual drive to complete their activities, hide the virtual drive from the operating system, flush cache, pause all the background operations, and save the current progress in disk data format, allowing you to move the drive. When you move a virtual drive, all other drives belonging to the same drive group inherit the same change as the moved drive.
When the last configured physical drive on the group is removed from the current controller, the drive group becomes foreign and all foreign configuration rules apply to the group. However, the Transport Ready feature does not change any foreign configuration behavior.
You can also clear a virtual drive from the Transport Ready state. This makes the virtual drive available to the operating systems.
Following restrictions apply to a transport ready virtual drive:
• Only a maximum of 16 transport ready drive groups are currently supported.
• This feature is not supported on high availability.
• A virtual drive cannot be set as transport ready under these conditions:
• When a virtual drive of a drive group is being reconstructed
• When a virtual drive of a drive group contains a pinned cache
• When a virtual drive of a drive group is marked as cacheable or associated with a cachecade virtual drive
• If a virtual drive is a cachecade virtual drive
• If a virtual drive is offline
• If a virtual drive is a bootable virtual drive
Setting a Virtual Drive as Transport Ready
Before you begin
• You must log in with admin privileges to perform this task.
• The virtual drive must be in optimal state to enable transport ready.
Procedure
Step 1
Step 2
Step 3
Step 4
Step 5
In the Navigation pane, click the Storage menu.
On the Storage menu, click the appropriate LSI MegaRAID or HBA Controller.
On the Work pane, click the Virtual Drive Info tab.
In the Virtual Drives area, choose the drive that you want set as transport ready.
In the Actions area, click Set Transport Ready .
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
211
Managing Storage Adapters
Clearing a Virtual Drive from Transport Ready State
Step 6
The Set Transport Ready dialog box displays.
Update the following properties in the dialog box:
Name
Initialize Type drop-down list
Description
Allows you to select the initialization type using which you can set the selected virtual drive as transport ready. This can be one of the following:
• Exlude All — Excludes all the dedicated hot spare drives.
• Include All — Includes any exclusively available or shared dedicated hot spare drives.
• Include Dedicated Hot Spare Drive — Includes exclusive dedicated hot spare drives.
Set Transport Ready
Cancel
Note button button Sets the selected virtual drive as transport ready.
Cancels the action.
When you set a virtual drive to transport ready all the physical drives associated with it are displayed as Ready to Remove .
Clearing a Virtual Drive from Transport Ready State
Before you begin
• You must log in with admin privileges to perform this task.
• The virtual drive must be transport ready.
Procedure
Step 1
Step 2
Step 3
Step 4
Step 5
In the Navigation pane, click the Storage menu.
On the Storage menu, click the appropriate LSI MegaRAID or HBA controller.
On the Work pane, click the Virtual Drive Info tab.
In the Virtual Drives area, choose the drive to set as transport ready.
In the Actions area, click Clear Transport Ready .
This reverts the selected transport ready virtual drive to its original optimal state.
212
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Managing Storage Adapters
Importing Foreign Configuration
Importing Foreign Configuration
When one or more physical drives that have previously been configured with a different controller are inserted into a server, they are identified as foreign configurations. You can import these foreign configurations to a controller.
Important You cannot import a foreign configuration in the following two scenarios:
1.
When the secure virtual drive was created on server 1 (from which you want to import the configuration) using the remote key, and on server 2 (to which you want to import) using the local key.
2.
When server 2 is configured with another KMIP server, which is not a part of the server 1 KMIP server cluster.
In order to import the foreign configuration in these scenarios, change the controller security on server 2 from local key management to remote key management, and use the same KMIP server from the same cluster where the server 1 KMIP is configured.
Before you begin
You must log in with admin privileges to perform this task.
Procedure
Step 1
Step 2
Step 3
Step 4
In the Navigation pane, click the Storage menu.
In the RAID controller area, the Controller Info tab displays by default.
In the Actions area, click Import Foreign Config .
Note If KMIP is not enabled, a Secure Key Verification dialog box is displayed, prompting you to enter a security key to initiate the foreign configuration import process.
If KMIP is enabled, the Secure Key Verification dialog box is displayed with the following note:
"If drive security has been enabled via remote key management, specifying Security key is optional.
Click on verify to start foreign configuration import."
This allows you to click Verify without entering the Security Key, and initiate import.
Click OK to confirm.
Clearing Foreign Configuration
Important This task clears all foreign configuration on the controller. Also, all configuration information from all physical drives hosting foreign configuration is deleted. This action cannot be reverted.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
213
Managing Storage Adapters
Clearing a Boot Drive
Before you begin
You must log in with admin privileges to perform this task.
Procedure
Step 1
Step 2
Step 3
Step 4
In the Navigation pane, click the Storage menu.
On the Storage menu, click the appropriate LSI MegaRAID or HBA controller.
In the RAID Controller area, the Controller Info tab displays by default.
In the Actions area, click Clear Foreign Config .
Click OK to confirm.
Clearing a Boot Drive
Important This task clears the boot drive configuration on the controller. This action cannot be reverted.
Before you begin
You must log in with admin privileges to perform this task.
Procedure
Step 1
Step 2
Step 3
Step 4
In the Navigation pane, click the Storage menu.
On the Storage menu, click the appropriate LSI MegaRAID or HBA controller.
In the RAID Controller area, the Controller Info tab displays by default.
In the Actions area, click Clear Boot Drive .
Click OK to confirm.
Enabling JBOD Mode
Procedure
Step 1
Step 2
Step 3
Step 4
Step 5
In the Navigation pane, click the Storage menu.
On the Storage menu, click the appropriate LSI MegaRAID or HBA controller.
In the RAID Controller area, click the Physical Drive Info tab.
In the Physical Drives area, select an unconfigured good drive.
In the Actions area, click Enable JBOD .
214
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Managing Storage Adapters
Disabling a JBOD
Step 6 Click Ok to confirm.
Disabling a JBOD
Note This option is available only on some UCS C-Series servers.
Before you begin
JBOD option must be enabled for the selected controller.
Procedure
Step 1
Step 2
Step 3
Step 4
Step 5
Step 6
In the Navigation pane, click the Storage menu.
On the Storage menu, click the appropriate LSI MegaRAID or HBA controller.
In the RAID Controller area, click the Physical Drive Info tab.
In the Physical Drives area, select a JBOD drive.
In the Actions area, click Disable JBOD .
Click Ok to confirm.
Retrieving Storage Firmware Logs for a Controller
This task retrieves the storage firmware logs for the controller and places it in the /var/log location. This ensures that this log data is available when Technical Support Data is requested.
Before you begin
You must log in with admin privileges to perform this task.
Procedure
Step 1
Step 2
Step 3
Step 4
In the Navigation pane, click the Storage menu.
In the working area, the Controller Info tab displays by default.
In the Actions area, click Get Storage Firmware Log .
Click OK to confirm.
Important Retrieving storage firmware logs for a controller could take up to 2-4 minutes. Until this process is complete, do not initiate exporting technical support data.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
215
Managing Storage Adapters
Clearing Controller Configuration
Clearing Controller Configuration
Before you begin
You must log in with admin privileges to perform this task.
Procedure
Step 1
Step 2
Step 3
Step 4
In the Navigation pane, click the Storage menu.
In the Storage menu, click the appropriate LSI MegaRAID or HBA controller.
In the Controller Info area, click Clear All Configuration .
Click OK to confirm.
This clears the existing controller configuration.
Restoring Storage Controller to Factory Defaults
Before you begin
You must log in with admin privileges to perform this task.
Procedure
Step 1
Step 2
Step 3
Step 4
In the Navigation pane, click the Storage menu.
In the Storage menu, click the appropriate LSI MegaRAID or HBA controller.
In the Controller Info area, click Set Factory Defaults .
Click OK to confirm.
This restores the controller configuration to factory defaults.
Preparing a Drive for Removal
Note You can perform this task only on physical drives that display the Unconfigured Good status.
Before you begin
You must log in with admin privileges to perform this task.
216
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Managing Storage Adapters
Undo Preparing a Drive for Removal
Procedure
Step 1
Step 2
Step 3
Step 4
Step 5
Step 6
In the Navigation pane, click the Storage menu.
On the Storage menu, click the appropriate LSI MegaRAID or HBA controller.
In the RAID Controller area, click the Physical Drive Info tab.
In the Physical Drives area, select the drive you want to remove.
In the Actions area, click Prepare for Removal .
Click OK to confirm.
Undo Preparing a Drive for Removal
Before you begin
You must log in with admin privileges to perform this task.
Procedure
Step 1
Step 2
Step 3
Step 4
Step 5
Step 6
In the Navigation pane, click the Storage menu.
On the Storage menu, click the appropriate LSI MegaRAID or HBA controller.
On the RAID Controller area, click the Physical Drive Info tab.
In the Physical Drives area, select a drive with a status of Ready to Remove .
In the Actions area, click Undo Prepare for Removal .
Click OK to confirm.
Making a Dedicated Hot Spare
Before you begin
You must log in with admin privileges to perform this task.
Procedure
Step 1
Step 2
Step 3
Step 4
Step 5
In the Navigation pane, click the Storage tab.
On the Storage menu, click the appropriate LSI MegaRAID or HBA controller.
On the RAID Controller area, click the Physical Drive Info tab.
In the Physical Drives area, select an unconfigured good drive you want to make a dedicated hot spare.
In the Actions area, click Make Dedicated Hot Spare .
The Make Dedicated Hot Spare dialog box displays.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
217
Managing Storage Adapters
Making a Global Hot Spare
Step 6
Step 7
In the Virtual Drive Details area, update the following properties:
Name Description
Virtual Drive Number drop-down list
Select the virtual drive to which you want to dedicate the physical drive as hot spare.
Virtual Drive Name field The name of the selected virtual drive.
Make Dedicated Hot Spare button Creates the dedicated hot spare.
Cancel button Closes the dialog box without saving any changes made while the dialog box was open.
Click Make Dedicated Hot Spare to confirm.
Making a Global Hot Spare
Before you begin
You must log in with admin privileges to perform this task.
Procedure
Step 1
Step 2
Step 3
Step 4
Step 5
In the Navigation pane, click the Storage tab.
On the Storage menu, click the appropriate LSI MegaRAID or HBA controller.
In the RAID Controller area, click the Physical Drive Info tab.
In the Physical Drives area, select an unconfigured good drive you want to make a global hot spare.
In the Actions area, click Make Global Hot Spare .
Removing a Drive from Hot Spare Pools
Before you begin
You must log in with admin privileges to perform this task.
Procedure
Step 1
Step 2
Step 3
Step 4
In the Navigation pane, click the Storage menu.
On the Storage tab, click the appropriate LSI MegaRAID controller.
On the Work pane, click the Physical Drive Info tab.
In the Physical Drives area, select the global or dedicated hot spare you want to remove from the hot spare pools.
218
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Managing Storage Adapters
Toggling Physical Drive Status
Step 5 In the Actions area, click Remove From Hot Spare Pools .
Toggling Physical Drive Status
Before you begin
• You must log in with admin privileges to perform this task.
• The controller must support the JBOD mode and the JBOD mode must be enabled.
Procedure
Step 1
Step 2
Step 3
Step 4
Step 5
Step 6
Step 7
Step 8
In the Navigation pane, click the Storage tab.
On the Storage menu, click the appropriate LSI MegaRAID or HBA controller.
In the RAID Controller area, click the Physical Drive Info tab.
In the Physical Drives area, select the drive you want to set as unconfigured good.
In the Actions area, click Set State as Unconfigured Good .
Click OK to confirm that the JBOD mode be disabled.
The Set State as JBOD option is enabled.
To enable the JBOD mode for the physical drive, click Set State as JBOD .
Click OK to confirm.
The Set State as Unconfigured Good option is enabled.
Setting a Physical Drive as a Controller Boot Drive
Before you begin
• You must log in with admin privileges to perform this task.
• The controller must support the JBOD mode and the JBOD mode must be enabled.
Procedure
Step 1
Step 2
Step 3
Step 4
Step 5
In the Navigation pane, click the Storage menu.
On the Storage menu, click the appropriate LSI MegaRAID or HBA controller.
In the RAID Controller area, click the Physical Drive Info tab.
In the Physical Drives area, select the drive you want to set as boot drive for the controller.
In the Actions area, click Set as Boot Drive .
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
219
Managing Storage Adapters
Initializing a Virtual Drive
Step 6 Click OK to confirm.
Initializing a Virtual Drive
All data on a virtual drive is lost when you initialize the drive. Before you run an initialization, back up any data on the virtual drive that you want to save.
Before you begin
You must log in with admin privileges to perform this task.
Procedure
Step 1
Step 2
Step 3
Step 4
Step 5
Step 6
Step 7
Step 8
In the Navigation pane, click the Storage menu.
On the Storage menu, click the appropriate LSI MegaRAID or HBA controller.
In the RAID Controller area, click the Virtual Drive Info tab.
In the Virtual Drives area, choose the drive that you want to initialize.
In the Actions area, click Initialize .
The Initialize Virtual Drive dialog box displays.
Choose the type of initialization you want to use for the virtual drive.
This can be one of the following:
• Fast Initialize —This option allows you to start writing data to the virtual drive immediately.
• Full Initialize —A complete initialization is done on the new configuration. You cannot write data to the new virtual drive until the initialization is complete.
Click Initialize VD to initialize the drive, or Cancel to close the dialog box without making any changes.
To view the status of the task running on the drive, in the Operations area, click Refresh .
The following details are displayed:
Name
Operation
Description
Name of the operation that is in progress on the drive.
Progress in %
Elapsed Time in secs
Progress of the operation, in percentage complete.
The number of seconds that have elapsed since the operation began.
220
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Managing Storage Adapters
Set as Boot Drive
Set as Boot Drive
Before you begin
You must log in with admin privileges to perform this task.
Procedure
Step 1
Step 2
Step 3
Step 4
Step 5
Step 6
In the Navigation pane, click the Storage menu.
On the Storage menu, click the appropriate LSI MegaRAID or HBA controller.
In the RAID Controller area, click the Virtual Drive Info tab.
In the Virtual Drives area, choose the drive from which the controller must boot.
In the Actions area, click Set as Boot Drive .
Click OK to confirm.
Editing a Virtual Drive
Procedure
Step 1
Step 2
Step 3
Step 4
Step 5
Step 6
In the Navigation pane, click the Storage menu.
On the Storage menu, click the appropriate LSI MegaRAID or HBA controller.
In the RAID Controller area, click the Virtual Drive Info tab.
In the Virtual Drives area, click Edit Virtual Drive .
Review the instructions, and then click OK .
The Edit Virtual Drive dialog box displays before prompting you to take a backup of your data.
From the Select RAID Level to migrate drop-down list, choose a RAID level.
See the following table for RAID migration criteria:
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
221
Managing Storage Adapters
Editing a Virtual Drive
Name
Select RAID Level to migrate drop-down list
Description
Select the RAID level to which you want to migrate. Migrations are allowed for the following RAID levels:
• RAID 0 to RAID 1
• RAID 0 to RAID 5
• RAID 0 to RAID 6
• RAID 1 to RAID 0
• RAID 1 to RAID 5
• RAID 1 to RAID 6
• RAID 5 to RAID 0
• RAID 6 to RAID 0
• RAID 6 to RAID 5
When you are migrating from one raid level to another, the data arms of the new RAID level should be equal to or greater than the existing one.
In case of RAID 6, the data arms will be number of drives minus two, as RAID 6 has double distributed parity. For example, when you create
RAID 6 with eight drives, the number of data arms will be 8 – 2 = 6. In this case, if you are migrating from RAID 6 to RAID 0, RAID 0 must have a minimum of six drives. If you select lesser number of drives then
Edit or Save button will be disabled.
If you are adding, you can migrate to RAID 0 as you will not be deleting any drives.
Note RAID level migration is not supported in the following cases:
• When there are multiple virtual drives in a RAID group.
• With a combination of SSD/HDD RAID groups.
Step 7
Step 8
From the Write Policy drop-down list in the Virtual Drive Properties area, choose one of the following:
• Write Through — Data is written through the cache and to the physical drives. Performance is improved, because subsequent reads of that data can be satisfied from the cache.
• Write Back — Data is stored in the cache, and is only written to the physical drives when space in the cache is needed. Virtual drives requesting this policy fall back to Write Through caching when the BBU cannot guarantee the safety of the cache in the event of a power failure.
• Write Back Bad BBU —With this policy, write caching remains Write Back even if the battery backup unit is defective or discharged.
Click Save Changes .
222
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Managing Storage Adapters
Deleting a Virtual Drive
Deleting a Virtual Drive
Important This task deletes a virtual drive, including the drives that run the booted operating system. So back up any data that you want to retain before you delete a virtual drive.
Before you begin
You must log in with admin privileges to perform this task.
Procedure
Step 1
Step 2
Step 3
Step 4
Step 5
Step 6
In the Navigation pane, click the Storage menu.
On the Storage menu, click the appropriate LSI MegaRAID or HBA controller.
In the RAID Controller area, click the Virtual Drive Info tab.
In the Virtual Drives area, select the virtual drive you want to delete.
In the Actions area, click Delete Virtual Drive .
Click OK to confirm.
Hiding a Virtual Drive
Before you begin
You must log in with admin privileges to perform this task.
Procedure
Step 1
Step 2
Step 3
Step 4
Step 5
Step 6
In the Navigation pane, click the Storage menu.
On the Storage menu, click the appropriate LSI MegaRAID or HBA controller.
On the RAID Controller area, click the Virtual Drive Info tab.
In the Virtual Drives area, select the virtual drive you want to hide.
In the Actions area, click Hide Drive .
Click OK to confirm.
Starting Learn Cycles for a Battery Backup Unit
Before you begin
You must log in with admin privileges to perform this task.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
223
Managing Storage Adapters
Viewing Storage Controller Logs
Procedure
Step 1
Step 2
Step 3
Step 4
Step 5
In the Navigation pane, click the Storage menu.
On the Storage menu, click the appropriate LSI MegaRAID or HBA controller.
In the RAID Controller area, click the Battery Backup Unit tab.
From the Actions pane, click Start Learn Cycle .
A dialog prompts you to confirm the task.
Click OK .
Viewing Storage Controller Logs
Before you begin
You must log in with admin privileges to perform this task.
Procedure
Step 1
Step 2
Step 3
In the Navigation pane, click the Storage menu.
On the Storage menu, click the appropriate LSI MegaRAID or HBA controller.
In the RAID Controller area, click Storage Log tab and review the following information:
Name
Time column
Description
The date and time the event occurred.
Severity column The event severity. This can be one of the following:
• Emergency
• Alert
• Critical
• Error
• Warning
• Notice
• Informational
• Debug
Description column A description of the event.
224
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Managing Storage Adapters
Viewing SSD Smart Information for MegaRAID Controllers
Viewing SSD Smart Information for MegaRAID Controllers
You can view smart information for a solid state drive. Complete these steps:
Procedure
Step 1
Step 2
Step 3
Step 4
In the Navigation pane, click the Storage tab.
On the Storage menu, click the appropriate LSI MegaRAID Controller.
On the Work pane, click the Physical Drive Info tab.
In the Smart Information area, review the following information:
Name Description
Power Cycle Count field
Power on Hours field
Percentage Life Left field
Number of power cycles that the drive went through from the time it was manufactured.
Total number of hours that the drive is in the 'Power
On' mode.
The number of write cycles remaining in a solid state drive (SSD). For instance, if an SSD is capable of 100 write cycles during its life time, and it has completed
15 writes, then the percentage of life left in the drive is 85%. Each percentage range is represented in a different color. For instance, green for 75% to 100% and red for 1 to 25%.
Wear Status in Days field
Operating Temperature
Percentage Reserved Capacity Consumed
Time of Last Refresh field field field
The number of days an SSD has gone through with the write cycles.
SSD vendors provide a finite number of writes per day on the SSD, based on which, you can calculate the total number of years the SSD would continue to work.
The current temperature of the drive at which the selected SSD operates at the time of selection.
The total capacity (out of the percentage reserved for it) consumed by the SSD.
Time period since the drive was last refreshed.
Viewing NVMe Controller Details
Before you begin
• The server must be powered on.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
225
Managing Storage Adapters
Viewing NVMe Controller Details
Procedure
Step 1
Step 2
Step 3
Step 4
Step 5
Step 6
Step 7
Step 8
In the Navigation pane, click the Storage menu.
In the Storage menu, click the appropriate NVMe controller.
In the Controller area, the Controller Info tab displays by default.
In the Work pane's Health/Status area, review the following information:
Name Description
Composite Health field The health of the controller. This can be one of the following:
• Good - All the drives under the controller is in optimal state.
• Severe Fault - When one or more drives under the controller is in faulty state.
• N/A
Drive Count field The number of drives configured on the controller.
In the Manufacturer Information area, review the following information:
Name Description
Vendor ID field The vendor ID of the NVMe controller.
Product ID field
Component ID field
Product Revision field
The controller product ID.
The component ID of the NVMe controller.
The board revision number, if any.
In the Group PCI Info area, review the following information:
Name Description
Vendor ID
Device ID field field
The PCI vendor ID, in hexadecimal.
The PCI device ID, in hexadecimal.
In the Group Firmware Information area, review the following information:
Name Description
Running Firmware Images field NVMe drive fimware version.
In the Group Switch Information area, review the following information:
226
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Managing Storage Adapters
Name
Temperature field
Switch Status field
Link Status field
Shutdown Temperature field
Viewing NVMe Physical Drive Details
Description
Temperature in degree centigrade of the switch.
The current status of the switch. This can be one of the following:
• Optimal — The controller is functioning properly.
• Failed — The controller is not functioning.
• Unresponsive — The controller is down.
The current status of the link. This field indicates if any of the upstream or downstream links in the switch are down. Individual drive also has a link status that can then be used to identify which drive causes the switch link status to be Link Degraded. This can be one of the following:
• Optimal — The controller is functioning properly.
• Failed — The controller is not functioning.
• Unresponsive — The controller is down.
This is the temperature beyond which the safe operation of switch is not guaranteed and recommends shutting down the system.
Viewing NVMe Physical Drive Details
Before you begin
• The server must be powered on.
Procedure
Step 1
Step 2
Step 3
In the Navigation pane, click the Storage menu.
In the Storage menu, click the appropriate NVMe controller.
Click Physical Drive tab and review the following information:
Name Description
Physical Drives column The list of available physical drives.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
227
Managing Storage Adapters
Viewing NVMe Physical Drive Details
Step 4
Name
PCI Slot column
Managed ID column
Product Name column
Firmware Version column
Vendor column
Serial Number column
Description
The PCI slot number in which the physical drive resides.
Internal ID referenced in debug.
The name of the drive as assigned by the vendor.
The firmware version running on the drive.
The drive vendor name.
Drive serial number.
Physical Drives Details
Note These details of a physical drive are displayed when you expand one of the listed physical drives.
Name
PCI Slot field
Managed ID
Throttle State field
Serial Number field field
Chip Temperature field
Percentage Drive Life Used
Device ID field
Sub Device ID
Drive Status field field
Performance Level field
Shutdown Temperature field field
Percentage of Total Power On Hours field
Vendor ID field
SubVendor ID field
LED Fault Status field
Description
The PCI slot number in which the physical drive resides.
Internal ID referenced in debug.
The state of the throttle.
Controller serial number.
Temperature of the drive in degree centigrade. This is the max temperature read from internal sensors in the drive.
The percentage of the drive life that is used up.
The PCI device ID, in hexadecimal.
The PCI subdevice ID, in hexadecimal.
Status of the drive.
Indicates the performance of the drive.
Temperature at which the drive shuts down.
The percentage of time the drive was powered on.
The PCI vendor ID, in hexadecimal.
The PCI subvendor ID, in hexadecimal.
The status of the LED fault.
228
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Managing Storage Adapters
Name
Controller Temperature field
Running Firmware Images field
Throttle Start Temperature field
Viewing PCI Switch Details
Description
Temperature of the controller in degree centigrade.
This is the overall composite temperature of the
NVMe subsystem ID.
NVMe drive fimware version.
Temperature at which the drive starts to throttle.
Viewing PCI Switch Details
Before you begin
The server must be powered on, or the properties will not display.
Procedure
Step 1
Step 2
In the Navigation pane, click the Storage menu.
In the Storage menu, click the appropriate PCI Switch controller. Review the following information:
Controller Area
Name
Composite Health field
PCI Slot field
Description
Indicates the overall health status of the PCI switch.
Displays if there are any correctable or uncorrectable errors and also reflects the status of the upstream and downstream ports.
PCI slot in which the controller is installed.
Controller Type
Product Name
Product Revision field column column
Type of PCI controller present in the slot.
Name of the PCI controller.
Displays the controller configuration revision information.
Switch Information Area
Name
Temperature field
Description
Temperature of the switch in degree Celsius.
Manufacturer Information Area
Name
Manufacturer column
Description
Manufacture of the PCI switch.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
229
Managing Storage Adapters
Starting Copyback Operation
Name
Vendor ID column
Sub Vendor ID column
Device ID column
Sub Device ID column
GPU and PCI Adapters Area
Name
Slot column
Link Status column
Link Speed (GT/s) column
Link Width column
Status column
Description
The switch ID assigned by the vendor.
The secondary switch ID assigned by the vendor.
The device ID assigned by the vendor.
The secondary device ID assigned by the vendor.
Description
Slot IDs in which GPUs or PCI Adapters are present.
The current status of the link. This field indicates if any of the upstream or downstream links in the switch are down.
Displays the speed of an adapter card installed in the PCI slot.
The number of data lanes of the link.
Status of the adapter.
Starting Copyback Operation
Procedure
Step 1
Step 2
Step 3
Step 4
Step 5
Step 6
Step 7
Step 8
Step 9
In the Navigation pane, click the Storage menu.
On the Storage menu, click the appropriate LSI MegaRAID or HBA controller.
In the RAID Controller area, click the Physical Drive Info tab.
In the Physical Drives area, select a drive, which is in online state.
In the Actions area, click Start Copyback .
A Start Copyback Operation dialog box appears.
Select the Destination Physical Drive to which the copyback operation needs to be done.
Click Start Copyback .
You can also perform the following copyback operations:
• Pause Copyback - If the drive is in copyback state, you can pause the copyback operation.
• Resume Copyback - The paused copyback operation can be resumed.
• Abort Copyback - If the drive is in copyback state, you can abort the copyback operation.
230
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Managing Storage Adapters
Managing the Flexible Flash Controller
Managing the Flexible Flash Controller
Cisco Flexible Flash
On the M5 servers, Flexible Flash Controller is inserted into the mini storage module socket. The mini storage socket is inserted into the M.2 slot on the motherboard. M.2 slot also supports SATA M.2 SSD slots.
Note M.2 slot does not support NVMe in this release.
Some C-Series Rack-Mount Servers support an internal Secure Digital (SD) memory card for storage of server software tools and utilities. The SD card is hosted by the Cisco Flexible Flash storage adapter.
The SD storage is available to Cisco IMC as a single hypervisor (HV) partition configuration. Prior versions had four virtual USB drives. Three were preloaded with Cisco UCS Server Configuration Utility, Cisco drivers and Cisco Host Upgrade Utility, and the fourth as user-installed hypervisor. A single HV partition configuration is also created when you upgrade to the latest version of Cisco IMC or downgrade to the prior version, and reset the configuration.
For more information about installing and configuring the M.2 drives, see the Storage Controller
Considerations (Embbeded SATA RAID Requirements) and Replacing an M.2 SSD in a Mini-Storage
Carrier For M.2
sections in the Cisco UCS Server Installation and Service Guide for the C240 M5 servers at this URL: https://www.cisco.com/c/en/us/support/servers-unified-computing/ucs-c-series-rack-servers/ products-installation-guides-list.html
For information about the Cisco software utilities and packages, see the Cisco UCS C-Series Servers
Documentation Roadmap at this URL: http://www.cisco.com/go/unifiedcomputing/c-series-doc
Card Management Feature in the Cisco Flexible Flash Controller
The Cisco Flexible Flash controller supports management of both single and two SD cards as a RAID-1 pair.
With the introduction of card management, you can perform the following tasks:
Note • If you want to upgrade from version 1.4(5e) to 1.5(4) or higher versions, you must first upgrade to version1.5(2) and then upgrade to a higher version of Cisco IMC.
• Reset the Cisco Flexible Flash controller to load the latest Flex Flash firmware after every Cisco IMC firmware upgrade.
Action
Reset Cisco Flex Flash
Reset Partition Defaults
Description
Allows you to reset the controller.
Allows you to reset the configuration in the selected slot to the default configuration.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
231
Managing Storage Adapters
Upgrading from Single Card to Dual Card Mirroring with FlexFlash
Action
Synchronize Card Configuration
Configure Operational Profile
Description
Allows you to retain the configuration for an SD card that supports firmware version 253 and later.
Allows you to configure the SD cards on the selected
Cisco Flexible Flash controller.
RAID Partition Enumeration
Non-RAID partitions are always enumerated from the primary card and the enumeration does not depend on the status of the primary card.
Following is the behavior of the RAID partition enumeration when there are two cards in the Cisco Flexible
Flash controller:
Scenario
Single card
Behavior
RAID partitions are enumerated if the card is healthy, and if the mode is either Primary or
Secondary-active .
Dual paired cards
Dual unpaired cards
RAID partitions are enumerated if one of the cards is healthy.
When only one card is healthy, all read/write operations occur on this healthy card. You must use
UCS SCU to synchronize the two RAID partitions.
If this scenario is detected when the server is restarting, then neither one of the RAID partitions is enumerated.
If this scenario is detected when the server is running, when a user connects a new SD card, then the cards are not managed by the Cisco Flexible Flash controller. This does not affect the host enumeration.
You must pair the cards to manage them. You can pair the cards using the Reset Partition Defaults or
Synchronize Card Configuration options.
Upgrading from Single Card to Dual Card Mirroring with FlexFlash
You can upgrade from a single card mirroring to dual card mirroring with FlexFlash in one of the following methods:
• Add an empty FlexFlash card to the server, and then upgrade its firmware to the latest version.
• Upgrade the FlexFlash firmware to the latest version and then add an empty card to the server.
Prior to using either of these methods, you must keep in mind the following guidelines:
• To create RAID1 mirroring, the empty card that you want to add to the server must be of the exact size of the card that is already in the server. Identical card size is a must to set up RAID1 mirroring.
232
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Managing Storage Adapters
Configuring the Flexible Flash Controller Properties
• Ensure that the card with valid data in the Hypervisor partition is marked as the primary healthy card.
You can determine this state either in the Cisco IMC GUI or from the Cisco IMC CLI. To mark the state of the card as primary healthy, you can either use the Reset Configuration option in the Cisco IMC GUI or run the reset-config command in the Cisco IMC CLI. When you reset the configuration of a particular card, the secondary card is marked as secondary active unhealthy.
• In a Degraded RAID health state all read-write transactions are done on the healthy card. In this scenario, data mirroring does not occur. Data mirroring occurs only in the Healthy RAID state.
• Data mirroring is only applicable to RAID partitions. In the C-series servers, only Hypervisor partitions operate in the RAID mode.
• If you have not configured SD cards for use with prior versions, then upgrading to the latest version loads the latest 253 firmware and enumerates all four partitions to the host.
While upgrading versions of the FlexFlash, you may see the following error message:
Unable to communicate with Flexible Flash controller: operation ffCardsGet, status
CY_AS_ERROR_INVALID_RESPONSE”
In addition, the card status may be shown as missing . This error occurs because you accidently switched to an alternate release or a prior version, such as 1.4(x). In this scenario, you can either revert to the latest version, or you can switch back to the FlexFlash 1.4(x) configuration. If you choose to revert to the latest Cisco IMC version, then the Cisco FlexFlash configuration remains intact. If you choose to switch back to the prior version configuration, you must reset the Flexflash configuration. In this scenario, you must be aware of the following:
• If multiple cards are present, and you revert to a prior version, then the second card cannot be discovered or managed.
• If the card type is SD253, then you must run the reset-config command twice from the Cisco IMC CLI
- once to reload the old firmware on the controller and to migrate SD253 to SD247 type, and the second time to start the enumeration.
Configuring the Flexible Flash Controller Properties
After you upgrade to the latest verison of Cisco IMC or downgrade to a prior version, and reset the configuration, the server will access HV partition only.
Before you begin
• You must log in with admin privileges to perform this task.
• Cisco Flexible Flash must be supported by your platform.
Note This task results in the host re-scanning all the virtual drives, and a loss of virtual drive connectivity. We recommend that you configure the Cisco Flexible Flash controller properties before using any virtual drives, or power down the host prior to starting this task
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
233
Managing Storage Adapters
Configuring the Flexible Flash Controller Cards
Procedure
Step 1
Step 2
Step 3
Step 4
Step 5
In the Navigation pane, click the Storage tab.
On the Storage tab, click Cisco FlexFlash .
In the Controller Info tab, click Configure Operational Profile .
In the Operational Profile dialog box, update the following fields:
Table 2: Operational Profile Fields for M5 Servers
Name
Controller field
Description
The system-defined name of the selected Cisco Flexible Flash controller.
This name cannot be changed.
Firmware Operating Mode field System displayed message. Displays the firmware operating mode as
Mirror.
SLOT-1 Read Error Threshold field
The number of read errors that are permitted while accessing Slot 1 of the Cisco Flexible Flash card. If the number of read errors exceeds this threshold on a card, the card is marked unhealthy.
To specify a read error threshold, enter an integer between 1 and 255.
To specify that the card should never be disabled regardless of the number of errors encountered, enter 0 (zero).
SLOT-1 Write Error Threshold field
The number of write errors that are permitted while accessing Slot 1 of the Cisco Flexible Flash card. If the number of write errors exceeds this threshold on a card, the card is marked unhealthy.
To specify a write error threshold, enter an integer between 1 and 255.
To specify that the card should never be disabled regardless of the number of errors encountered, enter 0 (zero).
Click Save .
Configuring the Flexible Flash Controller Cards
Before you begin
• You must log in with admin privileges to perform this task.
• Cisco Flexible Flash must be supported by your platform.
Note This task results in the host re-scanning all the virtual drives, and a loss of virtual drive connectivity. We recommend that you configure the Cisco Flexible Flash controller properties before using any virtual drives, or power down the host prior to starting this task.
234
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Managing Storage Adapters
Resetting the Flexible Flash Controller
Procedure
Step 1
Step 2
Step 3
Step 4
In the Navigation pane, click the Storage tab.
On the Storage tab, click Cisco FlexFlash .
In the Actions area, click Configure Cards .
Configure Cards dialog box appears.
In the Configure Cards dialog box, update the following fields:
Name
Mode field
Description
Displays the mode type as Mirror.
Mirror Partition Name field
Auto Sync checkbox
The name that you want to assign to the partition.
If selected, data from the selected primary card syncs automatically with the secondary card.
Note • There must be two cards for you to choose this option.
• If this option is selected, data on the secondary card is erased and overwritten by the data on the primary card.
• The status of this is displayed under the Virtual Drive tab.
Select Primary Card drop-down Slot that you want to set as the primary card. This can be one of the following:
• Slot1
• Slot2
Virtual Drive drop-down The virtual drive type. This can be one of the following:
• Removable
• Non Removable
Step 5 Click Save .
The cards are configured in the chosen mode.
Resetting the Flexible Flash Controller
In normal operation, it should not be necessary to reset the Cisco Flexible Flash. We recommend that you perform this procedure only when explicitly directed to do so by a technical support representative.
Note This operation will disrupt traffic to the virtual drives on the Cisco Flexible Flash controller.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
235
Managing Storage Adapters
Enabling Virtual Drives
Before you begin
• You must log in with admin privileges to perform this task.
• Cisco Flexible Flash must be supported by your platform.
Procedure
Step 1
Step 2
Step 3
Step 4
On the Storage Adapters pane, click Cisco FlexFlash .
In the Cisco FlexFlash pane, click the Controller Info tab.
In the Actions area, click Reset FlexFlash Controller .
Click OK to confirm.
Enabling Virtual Drives
Before you begin
• You must log in with admin privileges to perform this task.
• Cisco Flexible Flash must be supported by your platform.
Note This task results in the host re-scanning all the virtual drives, and a loss of virtual drive connectivity. We recommend that you configure the Cisco Flexible Flash controller properties before using any virtual drives.
Procedure
Step 1
Step 2
Step 3
Step 4
Step 5
Step 6
In the Navigation pane, click the Storage tab.
On the Storage tab, click Cisco FlexFlash .
Click the Virtual Drive Info tab.
In the Virtual Drive Info tab, click Enable/Disable Virtual Drive(s) .
In the Enable/Disable VD(s) dialog box, select the virtual drives that you want to enable.
Click Save .
The selected virtual drives are enabled to the host.
Erasing Virtual Drives
Before you begin
• You must log in with admin privileges to perform this task.
236
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Managing Storage Adapters
Syncing Virtual Drives
• Cisco Flexible Flash must be supported by your platform.
Note This task results in the host re-scanning all the virtual drives, and a loss of virtual drive connectivity. We recommend that you configure the Cisco Flexible Flash controller properties before using any virtual drives.
Procedure
Step 1
Step 2
Step 3
Step 4
Step 5
Step 6
In the Navigation pane, click the Storage tab.
On the Storage tab, click Cisco FlexFlash .
Click the Virtual Drive Info tab.
In the Virtual Drive Info tab, click Erase Virtual Drive(s) .
In the Erase Virtual Drive(s) dialog box, select the virtual drives that you want to erase.
Click Save .
Data on the selected virtual drives is erased.
Syncing Virtual Drives
Before you begin
• You must log in with admin privileges to perform this task.
• Cisco Flexible Flash must be supported by your platform.
• Cards must be in mirror mode.
Note This task results in the host re-scanning all the virtual drives, and a loss of virtual drive connectivity. We recommend that you configure the Cisco Flexible Flash controller properties before using any virtual drives.
Procedure
Step 1
Step 2
Step 3
Step 4
Step 5
In the Navigation pane, click the Storage tab.
On the Storage tab, click Cisco FlexFlash .
Click the Virtual Drive Info tab.
In the Virtual Drive Info tab, click Sync Virtual Drive .
Click OK in the confirmation dialog box.
Syncs the virtual drive hypervisor with the primary card.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
237
Managing Storage Adapters
Viewing FlexFlash Log Details
Viewing FlexFlash Log Details
Procedure
Step 1
Step 2
Step 3
Step 4
In the Navigation pane, click the Storage menu.
In the Storage menu, click the Cisco Flexible Flash Controller.
In the FlexFlash Logs tab's FlexFlash LogTable area, review the following fields:
Name Description
Time column
Severity column
The date and time the event occurred.
The event severity. This can be one of the following:
• Emergency
• Alert
• Critical
• Error
• Warning
• Info
• Notice
• Debug
Description column A description of the event.
In the FlexFlash Logs tab's Actions area, review the following fields:
238
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Managing Storage Adapters
Viewing FlexFlash Log Details
Step 5
Name
Show drop-down list
Description
Customize the way you want to view Cisco IMC log entries using filters. These can be:
• Quick Filter — Default view
• Advanced Filter — Filter options to display the log entries based on one or more criteria. Using the matching rule, you can view entries matching all the rules or any one combination of rules you specified in the Filter fields.
Click + to add new filtering criteria.
Click Go to view the entries matching the filter criteria that you set.
Click the Save icon to save the filter criteria that you set. This becomes a user-defined filter which you can use later.
Note The user-defined filter appears in the
Manage Preset Filters dialog box.
• All —Displays all entries
• Manage Preset Filters —Displays user-defined filters. You can edit or remove the user-defined filter from this dialog box.
• List of pre-defined filters — Displays the system-defined filters.
Filter icon
Column drop-down list
Displays or hides the quick filter fields.
Allows you to choose the columns you want to view.
In the FlexFlash Logs tab's Log Navigation Toolbar area, review the following fields:
Name
<<Newest
Description
If there are more events than can fit on a single page, click this link to view the newest entries.
The total number of entries displayed depends on the setting in the
Entries per Page drop-down list.
<Newer If there are more events than can fit on a single page, click this link to view the next page of entries that are newer than the set you are currently viewing.
Log Entries field This field displays which log entries are currently being shown in the table.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
239
Managing Storage Adapters
Managing the FlexUtil Controller
Name
Older>
Oldest>>
Page Number drop-down list
Number of Rows field
Description
If there are more events than can fit on a single page, click this link to view the next page of entries that are older than the set you are currently viewing.
If there are more events than can fit on a single page, click this link to view the oldest entries.
Allows you to navigate to a specific page. Select the page number from the drop-down list.
Displays the rows displayed in the current page.
Managing the FlexUtil Controller
The C-Series M5 Rack-Mount servers support microSD memory card for storage of server software tools and utilities. Riser 1 has this microSD memory card slot. Cisco FlexUtil supports only 32GB microSD card.
The following user visible partitions are present on the microSD card:
• Server Configuration Utility (SCU) – 1.25 GB
• Diagnostics – 0.25 GB
• Host Update Utility (HUU) – 1.5 GB
• Drivers – 8 GB
• User
Note The number of partitions and size of each partition on microSD is fixed.
At any time, two partitions can be mapped onto the host. These partitions (except the user partition ) can also be updated through a CIFS or NFS share. A second level BIOS boot order support is also available for all the bootable partitions.
Note User partition must be used only for storage. This partition does not support OS installations.
Configuring FlexUtil Controller Properties
Before you begin
You must log in with admin privileges to perform this task.
240
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Managing Storage Adapters
Resetting FlexUtil Card Configuration
Procedure
Step 1
Step 2
Step 3
Step 4
In the Navigation pane, click the Storage menu.
In the Storage menu, click the Cisco FlexUtil Controller.
In the General tab's Actions area, click Configure Operational Profile .
In the Operational Profile dialog box, update the following fields.
Name
Controller field
Description
The system-defined name of the selected Flex Util controller.
This name cannot be changed.
Read Error Threshold field
Write Error Threshold field
The number of read errors that are permitted while accessing the Flex
Util card. If the number of read errors exceeds this threshold on a card, the card is marked unhealthy.
To specify a read error threshold, enter an integer between 1 and 255.
To specify that the card should never be disabled regardless of the number of errors encountered, enter 0 (zero).
The number of write errors that are permitted while accessing the Flex
Util card. If the number of write errors exceeds this threshold on a card, the card is marked unhealthy.
To specify a write error threshold, enter an integer between 1 and 255.
To specify that the card should never be disabled regardless of the number of errors encountered, enter 0 (zero).
Resetting FlexUtil Card Configuration
Before you begin
You must log in with admin privileges to perform this task.
Procedure
Step 1
Step 2
Step 3
In the Navigation pane, click the Storage menu.
In the Storage menu, click the Cisco FlexUtil Controller.
In the General tab's Actions area, click Reset Card Configuration .
This action resets the FlexUtil card configuration to its default settings.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
241
Managing Storage Adapters
Viewing Cisco FlexUtil Controller Properties
Viewing Cisco FlexUtil Controller Properties
Procedure
Step 1
Step 2
Step 3
In the Navigation pane, click the Storage menu.
In the Storage menu, click the Cisco FlexUtil Controller.
In the General tab's General area, review the following fields:
Name Description
Product Name field
Controller Name
Controller Status field field
The name of the product.
The name for the controller.
The current status of the FlexUtil card. This can be one of the following:
• Card is absent
• Card is Unhealthy
• Metadata Read Error
• Card access error
• Invalid Card size
• Metadata is in failed state
• No partition, reset required
• Invalid partition, reset required
• Card is write protected
242
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Managing Storage Adapters
Viewing Physical Drive Properties
Name
Internal State field
Description
The internal state of the controller. This can be one of the following:
• Uninitialized —FlexUtil monitoring is not initialized.
• Initializing —FlexUtil monitoring is initializing.
• Configuring —The controller is determining the
FlexUtil card configuration.
• OK —The FlexUtil card is not connected to the host.
• Connecting —The controller is connecting to the host.
• Connected —The controller is connected to the host.
• Failed —The controller has failed. See the
Controller Status field for more details.
• Erasing —The FlexUtil card is being erased.
• Updating —The FlexUtil card is being updated.
• Resetting —The configuration on the card is reset.
Step 4
Step 5
In the General tab's Physical Drive Count area, review the following fields:
Name Description
Physical Drive Count field The number of FlexUtil cards detected in the server.
In the General tab's Virtual Drive Count area, review the following fields:
Name Description
Virtual Drive Count field The number of virtual drives configured on the
FlexUtil cards installed in the server.
Viewing Physical Drive Properties
Procedure
Step 1 In the Navigation pane, click the Storage menu.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
243
Managing Storage Adapters
Viewing Physical Drive Properties
Step 2
Step 3
In the Storage menu, click the Cisco FlexUtil Controller.
In the Physical Drive tab's General area, review the following fields:
Name
Drive
Description
Name of the drive.
Indicates whether the drive is present.
Drive Status
Serial Number field
Manufacturer ID
OEM ID field field
The serial number for the FlexUtil card.
The manufacturer ID for the FlexUtil card.
The OEM ID for the FlexUtil card, if any.
Product Name field
Product Revision field
Manufacturing Date field
Write Enabled field
The name of the FlexUtil card.
The revision number for the FlexUtil card.
The date the FlexUtil card was manufactured, in the format mm/yy.
If this field displays true , the FlexUtil card accepts writes.
Block Size field
Capacity field
Health
The block size on the FlexUtil card, in bytes.
The capacity of the FlexUtil card, in megabytes.
This can be one of the following:
• Healthy
• Unhealthy
Step 4
Step 5
In the Physical Drive tab's Error Counters area, review the following fields.
Name Description
Read Error Threshold field
Read Error Count field
The number of read errors that are permitted while accessing the FlexUtil card.
The number of read errors encountered while handling
I/O traffic since the FlexUtil card was first installed.
Write Error Threshold field
Write Error Count field
The number of write errors that are permitted while accessing the FlexUtil card.
The number of write errors encountered while handling I/O traffic since the FlexUtil card was first installed.
In the Physical Drive tab's Partition area, review the following fields.
244
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Managing Storage Adapters
Name
Partition Count field
Drives Enabled field
Viewing Virtual Drive Properties
Description
The number of partitions on the FlexUtil card.
The virtual drives enabled for access on the FlexUtil card.
Viewing Virtual Drive Properties
Procedure
Step 1
Step 2
Step 3
In the Navigation pane, click the Storage menu.
In the Storage menu, click the Cisco FlexUtil Controller.
In the Virtual Drive tab's Virtual Drives area, review the following fields.
Name Description
Virtual Drive
ID column
LUN ID column The name of the virtual drive.
Virtual drive ID.
The LUN ID, if available.
Drive Scope column
Size column
Drive Status column
How the virtual drive is configured. This will always be NON RAID .
The size of the virtual drive in megabytes.
Status of the drive. This can be one of the following:
• Healthy
• Unhealthy
Host Accessible column
Drive Type column
Indicates whether the virtual drive is mapped to the host. This can be one of the following:
• Connected
• Not-Connected
If this field displays connected , it means the virtual drive is mapped to the host.
Type of the drive. This will always be Removable .
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
245
Managing Storage Adapters
Viewing Virtual Drive Properties
Step 4
Name
Operation in Progress column
Description
Operation that is in progress. This can be one of the following:
• Erasing
• Erase-Pending
• Updating
• Update-Pending
• NA
Note If your reboot Cisco IMC while any operation is running, the operation will be aborted and after the reboot the state of the operation will be set to NA.
Last Operation Status
Resident Image column Status of the last operation. This can be one of the following:
• Erase-Success
• Erase-Failed
• Update-Success
• Update-Failed
Displays the name of the image file present in the virtual drive.
In the Virtual Drive tab's Actions area, review the following fields.
Name Description
Enable/Disable Virtual Drive(s) Allows you to enable or disable a virtual drive.
Erase Virtual Drive(s) Allows you to format the virtual drives to FAT 32 format.
Note You cannot cancel an erase operation in progress or a pending erase operation.
Add Image Allows you to add an ISO image configuration for the SCU, HUU, Diagnostics, and Drivers.
246
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Managing Storage Adapters
Name
Update Image
Mapping an Image to a Virtual Drive
Description
Allows you to update virtual drive with the ISO image.
Note • When erase or update is in progress or pending on any virtual drive, you cannot perform any actions available on the Virtual tab.
• Use the Cancel Update button to cancel an ongoing update operation.
Cancels any ongoing update operation.
Allows you to delete the ISO image configuration.
Cancel Update
Unmap Image
Mapping an Image to a Virtual Drive
Before you begin
You must log in with admin privileges to perform this task.
Procedure
Step 1
Step 2
Step 3
Step 4
Step 5
In the Navigation pane, click the Storage menu.
In the Storage menu, click the Cisco FlexUtil Controller.
Click the Virtual Drives tab.
In the Virtual Drives area, select the virtual drive, and click Add Image .
In the Add New Image dialog box, update the following fields:
Name
Volume field
Description
The identity of the image mounted for mapping. This can be one of the following:
• SCU
• Diagnostics
• HUU
• Drivers
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
247
Managing Storage Adapters
Mapping an Image to a Virtual Drive
Name
Mount Type drop-down list
Remote Share
Remote File field field
Description
The type of mapping. This can be one of the following:
• NFS —Network File System.
• CIFS —Common Internet File System.
• WWW(HTTP/HTTPS) —HTTP-based or HTTPS-based system.
The URL of the image to be mapped. The format depends on the selected
Mount Type :
• NFS —Use serverip:/share path .
• CIFS —Use //serverip/share path .
• WWW(HTTP/HTTPS) —Use http[s]://serverip/share.
The name and location of the .iso file in the remote share. Following are the example of remote share files:
• NFS — /softwares/ucs-cxx-scu-3.1.9.iso
• CIFS — /softwares/ucs-cxx-scu-3.1.9.iso
• WWW(HTTP/HTTPS) — http[s]://softwares/ucs-cxx-scu-3.1.9.iso
248
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Managing Storage Adapters
Updating an Image on the Virtual Drive
Name
Mount Options field
Description
Industry-standard mount options entered in a comma separated list. The options vary depending on the selected Mount Type .
If you are using NFS , leave the field blank or enter one or more of the following:
• ro
• rw
• nolock
• noexec
• soft
• port=VALUE
• timeo=VALUE
• retry=VALUE
If you are using CIFS , leave the field blank or enter one or more of the following:
• soft
• nounix
• noserverino
If you are using WWW(HTTP/HTTPS) , leave the field blank or enter the following:
• noauto
Note Before mounting the image, Cisco IMC tries to verify reachability to the end server by pinging the server.
• username=VALUE
• password=VALUE
Step 6 Optional: The Add Image button is a toggle button. After you map an image, if you want to unmap the same image from the drive, select the virtual drive, and click Unmap Image .
Updating an Image on the Virtual Drive
Before you begin
You must log in with admin privileges to perform this task.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
249
Managing Storage Adapters
Unmapping an Image From a Virtual Drive
Procedure
Step 1
Step 2
Step 3
Step 4
Step 5
In the Navigation pane, click the Storage menu.
In the Storage menu, click the Cisco FlexUtil Controller.
Click the Virtual Drives tab.
In the Virtual Drives area, select the virtual drive for which you want to update an image and click Update
Image .
Optional: If you want to cancel an ongoing update operation, click Cancel Update .
Unmapping an Image From a Virtual Drive
Before you begin
You must log in with admin privileges to perform this task.
Procedure
Step 1
Step 2
Step 3
Step 4
In the Navigation pane, click the Storage menu.
In the Storage menu, click the Cisco FlexUtil Controller.
Click the Virtual Drives tab.
In the Virtual Drives area, select the virtual drive for which you want to delete the image and click Unmap
Image .
Erasing a Virtual Drive
Before you begin
You must log in with admin privileges to perform this task.
Procedure
Step 1
Step 2
Step 3
Step 4
In the Navigation pane, click the Storage menu.
In the Storage menu, click the Cisco FlexUtil Controller.
Click the Virtual Drives tab.
In the Virtual Drives area, select the virtual drive you want to erase, and click Erase Virtual Drive .
250
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Managing Storage Adapters
Cisco Boot Optimized M.2 Raid Controller
Cisco Boot Optimized M.2 Raid Controller
Viewing Cisco Boot Optimized M.2 Raid Controller Details
Before you begin
The server must be powered on.
Procedure
Step 1
Step 2
Step 3
Step 4
Step 5
In the Navigation pane, click the Storage menu.
In the Storage menu, click the appropriate M.2 Raid controller.
In the Controller area, the Controller Info tab displays by default.
In the Work pane's Health/Status area, review the following information:
Name
Composite Health field
Description
The combined health of the controller, the attached drives, and the battery backup unit. This can be one of the following:
• Good
• Moderate Fault
• Severe Fault
• N/A
Controller Status field The current status of the controller. This can be one of the following:
• Optimal — The controller is functioning properly.
• Failed — The controller is not functioning.
In the Firmware Versions area, review the following information:
Name Description
Product Name field
Product PID field
The name of the Cisco Boot optimized M.2 Raid controller.
The product PID of the Cisco Boot optimized M.2
Raid controller.
Serial Number field The serial number of the Cisco Boot optimized M.2
Raid controller.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
251
Managing Storage Adapters
Viewing Cisco Boot Optimized M.2 Raid Controller Details
Step 6
Step 7
Step 8
Step 9
Name
Firmware Package Build field
Description
The active firmware package version number.
For the firmware component version numbers, see the
Running Firmware Images area.
In the PCI Info area, review the following information:
Name Description
PCI Slot field
Vendor ID
Device ID field field
SubVendor ID field
SubDevice ID field
The name of the PCIe slot in which the controller is located.
The PCI vendor ID, in hexadecimal.
The PCI device ID, in hexadecimal.
The PCI subvendor ID, in hexadecimal.
The PCI subdevice ID, in hexadecimal.
In the Manufacturing Data area, review the following information:
Name Description
Manufactured Date field
Revision No field
The manufacturing date of the Cisco Boot optimized
M.2 Raid controller, in the format yyyy-mm-dd.
The board revision number, if any.
In the Next Patrol Read Schedule area, review the following information:
Name Description
PR State field The patrol read state of the M.2 Raid controllers. It can be one of the following:
• ready
• stopped
• active
PR Schedule Mode field
Default state: N/A .
The patrol read schedule mode of the M.2 Raid controllers.
The PR Schedule Mode is manual by default.
In the Running Firmware Images area, review the following information:
252
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Managing Storage Adapters
Viewing Cisco Boot Optimized M.2 Raid Controller Details
Step 10
Step 11
Step 12
Step 13
Name
BIOS Version field
Firmware Version field
Boot Block Version field
Description
The BIOS option PROM version number.
The active firmware version number.
The boot block version number.
In the Virtual Drive Count area, review the following information:
Name Description
Virtual Drive Count field The number of virtual drives configured on the controller.
Degraded Drive Count field
Offline Drive Count field
The number of virtual drives in a degraded state on the controller.
The number of virtual drives that have failed on the controller.
In the Physical Drive Count area, review the following information:
Name Description
Disk Present Count field The number of physical drives present on the controller.
Critical Disk Count field
Failed Disk Count field
The number of physical drives in a critical state on the controller.
The number of physical drives that have failed on the controller.
In the Capabilities area, review the following information:
Name Description
RAID Levels Supported field The RAID levels supported by the controller.
Raid 1 —Simple mirroring.
In the HW Configuration area, review the following information:
Name Description
Number of Backend Ports field The number of SATA ports on the controller.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
253
Managing Storage Adapters
Viewing Physical Drive Info for Cisco Boot Optimized M.2 Raid Controller
Viewing Physical Drive Info for Cisco Boot Optimized M.2 Raid Controller
Before you begin
The server must be powered on.
Procedure
Step 1
Step 2
Step 3
In the Navigation pane, click the Storage menu.
In the Storage menu, click the appropriate M.2 raid controller.
Click Physical Drive Info tab and in the Physical Drives area, review the following information:
Name Description
Controller column
Physical Drive Number
Status column column
The name of the PCIe slot in which the controller drive is located.
The physical drive number.
The physical drive status. This can be one of the following:
• JBOD —The drive is in JBOD mode.
• Failed —The drive was in use, but it has failed.
• Offline —The drive is offline and cannot be accessed.
• Online —The drive is in use as part of a drive group.
• Predicted Failure —The drive is marked as due to fail soon by the controller.
• Rebuild —The drive is currently being rebuilt.
• Unknown —The drive status is unknown.
State column The state of the physical drive. This can be one of the following:
• JBOD — The physical drive is in JBOD state.
• Online — The physical drive is in use as part of a drive group.
• Failed — The physical drive is in failed state.
• Rebuild — The physical drive is in rebuild state.
254
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Managing Storage Adapters
Viewing Physical Drive Info for Cisco Boot Optimized M.2 Raid Controller
Step 4
Name
Health column
Description
The health of the physical drive. This can be one of the following:
• Good
• Moderate Fault
• Severe Fault
The health field includes both text and a color-coded icon. If the color-coded icon is:
• Green — It indicates normal operation.
• Yellow — It is an informational message.
• Red — It indicates warning, critical, and non-recoverable errors.
Drive Firmware
Model
Type
State column column column The firmware version running on the drive.
The drive vendor name.
Whether the drive is a hard drive (HDD) or a solid state drive (SSD).
In the Health/Status area, review the following information:
Name Description
Health The health of the physical drive. This can be one of the following:
• Good
• Moderate Fault
• Severe Fault
The state of the physical drive. This can be one of the following:
• JBOD — The physical drive is in JBOD state.
• Online — The physical drive is in use as part of a drive group.
• Failed — The physical drive is in failed state.
• Rebuild — The physical drive is in rebuild state.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
255
Managing Storage Adapters
Viewing Physical Drive Info for Cisco Boot Optimized M.2 Raid Controller
Step 5
Name
Status
Fault
Online
Description
The physical drive status. This can be one of the following:
• JBOD —The drive is in JBOD mode.
• Failed —The drive was in use, but it has failed.
• Offline —The drive is offline and cannot be accessed.
• Online —The drive is in use as part of a drive group.
• Predicted Failure —The drive is marked as due to fail soon by the controller.
• Rebuild —The drive is currently being rebuilt.
• Unknown —The drive status is unknown.
If this field displays true , the drive is in the failed state.
If this field displays true , the drive is in the online state.
In the Smart Information area, review the following information:
Name Description
Power Cycle Count
Power On Hours
Number of power cycles that were performed on the drive from the time it was manufactured. Power Cycle
Count this field.
Total number of hours that the drive is in the 'Power
On' mode.
Percentage Life Left
Wear Status in Days
Operating Temperature (°C)
Percentage Reserved Capacity Consumed
The number of write cycles remaining in a M.2 drive.
For instance, if an M.2 drive is capable of 100 write cycles during its life time, and it has completed 15 writes, then the percentage of life left in the drive is
85%. Each percentage range is represented in a different color. For instance, green for 75% to 100% and red for 1 to 25%.
The number of days an M.2 drive has gone through with the write cycles.
The current temperature of the drive at which the selected M.2 drive operates at the time of selection.
The total capacity (out of the percentage reserved for it) consumed by the M.2 drive.
256
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Managing Storage Adapters
Viewing Physical Drive Info for Cisco Boot Optimized M.2 Raid Controller
Step 6
Step 7
Step 8
Name
Time of Last Refresh
Description
Time period since the drive was last refreshed.
In the Operation Status area, review the following information:
Name Description
Operation The current operation that is in progress on the drive.
This can be one of the following:
• Rebuild in progress
• Patrol read in progress
Progress in % The progress of the operation, in percentage.
In the Inquiry Data area, review the following information:
Name Description
Product ID
Vendor
The drive product ID. This field generally displays the drive model number.
The vendor for the drive.
Drive Firmware
Drive Serial Number
The active firmware version on the drive.
The serial number for the drive.
In the General area, review the following information:
Name Description
The slot number in which the physical drive resides.
Slot Number
Raw Size
Negotiated Link Speed
The capacity of drive in megabytes, including the space used for formatting.
The speed of the link between the drive and the controller.
Media Type The drive type is a solid state drive (SSD).
The drive interface type.
Interface Type
Enclosure Association Indicates whether the drives are associated to the controller directly or not. This can be:
Direct attached —drives are directly attached to the controller.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
257
Managing Storage Adapters
Viewing the Virtual Drive Info for Cisco Boot Optimized M.2 Raid Controller
Viewing the Virtual Drive Info for Cisco Boot Optimized M.2 Raid Controller
Procedure
Step 1
Step 2
Step 3
In the Navigation pane, click the Storage menu.
In the Storage menu, click the M.2 Raid Controller.
Select the Virtual Drive Info tab and in the Virtual Drives area, review the following information:
Name Description
Virtual Drive Number
Name
Status column column column The number of the virtual drive.
The name of the virtual drive.
The virtual drive state. This can be one of the following:
• Partially Degraded —Virtual drive or physical drive rebuild is in progress.
• Degraded —One or more spans of the drive has no redundancy.
• Off Line —The drive is not visible to the host.
• Unknown —The virtual drive state is unknown.
• Optimal —The drive has full redundancy.
Health column The health of the virtual drive. This can be one of the following:
• Good
• Moderate Fault
• Severe Fault
The health field includes both text and a color-coded icon. If the color-coded icon is:
• Green — It indicates normal operation.
• Yellow — It is an informational message.
• Red — It indicates warning, critical, and non-recoverable errors.
Size column
RAID Level column
The capacity of the drive in megabytes.
The RAID level on the virtual drive.
Raid 1 —Simple mirroring.
258
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Managing Storage Adapters
Viewing the Virtual Drive Info for Cisco Boot Optimized M.2 Raid Controller
Step 4
Step 5
In the General area, review the following information:
Name Description
The name of the virtual drive.
Name
Strip Size The size of each strip, in KB.
In the Physical Drives area, review the following information:
Name Description
The physical drive number.
Physical Drive Number
State The state of the physical drive. This can be one of the following:
• JBOD — The physical drive is in JBOD state.
• Online — The physical drive is in use as part of a drive group.
• Failed — The physical drive is in failed state.
• Rebuild — The physical drive is in rebuild state.
Status The physical drive status. This can be one of the following:
• JBOD —The drive is in JBOD mode.
• Failed —The drive was in use, but it has failed.
• Offline —The drive is offline and cannot be accessed.
• Online —The drive is in use as part of a drive group.
• Predicted Failure —The drive is marked as due to fail soon by the controller.
• Rebuild —The drive is currently being rebuilt.
• Unknown —The drive status is unknown.
Step 6 In the Operation Status area, review the following information:
Name Description
Operation The current operation that is in progress on the drive.
This can be:
Rebuild in progress
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
259
Managing Storage Adapters
Viewing the Virtual Drive Info for Cisco Boot Optimized M.2 Raid Controller
Name
Progress in %
Description
The progress of the operation, in percentage.
260
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
C H A P T E R
13
Configuring Communication Services
This chapter includes the following sections:
•
•
•
Configuring XML API, on page 263
•
•
•
•
Configuring a Server to Send Email Alerts Using SMTP, on page 272
Configuring HTTP
Beginning with release 4.1(2b), Cisco IMC supports separate HTTPS and HTTP communication services.
You can disable only HTTP services using this functionality.
This functionality is supported only on the following servers:
• Cisco UCS C220 M5
• Cisco UCS C240 M5
• Cisco UCS C480 M5
• Cisco UCS C480 ML M5
• Cisco UCS C240 SD M5
• Cisco UCS C125 M5
• Cisco UCS S3260 M4/M5
Note If Redirect HTTP to HTTPS Enabled was disabled in any release earlier than 4.1(2b), then after upgrading to release 4.1(2b) or later, HTTP Enabled value is set to Disabled by the system.
Before you begin
You must log in as a user with admin privileges to perform this task.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
261
Configuring Communication Services
Configuring HTTP
Procedure
Step 1
Step 2
Step 3
Step 4
In the Navigation pane, click the Admin menu.
In the Admin menu, click Communication Services .
In the HTTP Properties area, update the following properties:
Name
HTTPS Enabled check box
Description
Warning Disabling this option terminates the exiting Cisco IMC Web
GUI session. Disabling this option, disables both HTTP and
HTTPS services to access Cisco IMC.
HTTP Enabled check box
This option enables only HTTPS services to access Cisco IMC.
Warning To successfully save any changes for this option, Cisco IMC
Web GUI is restarted automatically. Communication with the management controller is lost momentarily and you must log in again after the restart.
This option enables only HTTP services to access Cisco IMC.
Note If HTTPS is disabled, HTTP services to access Cisco IMC are also disabled.
Redirect HTTP to HTTPS
Enabled check box
HTTP Port
HTTPS Port field
Max Sessions field
Session Timeout field field
Active Sessions field
Note This option is applicable only when HTTP Enabled is checked.
If enabled, all attempts to communicate via HTTP are redirected to the equivalent HTTPS address.
We strongly recommend that you enable this option if you enable HTTP.
The port to use for HTTP communication. The default is 80.
The port to use for HTTPS communication. The default is 443
The number of seconds to wait between HTTP requests before the Cisco
IMC times out and terminates the session.
Enter an integer between 60 and 10,800. The default is 1,800 seconds.
The maximum number of concurrent HTTP and HTTPS sessions allowed on the Cisco IMC.
This value may not be changed.
The number of HTTP and HTTPS sessions currently running on the
Cisco IMC.
Click Save Changes .
262
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Configuring Communication Services
Configuring SSH
Configuring SSH
Before you begin
You must log in as a user with admin privileges to configure SSH.
Procedure
Step 1
Step 2
Step 3
Step 4
In the Navigation pane, click the Admin menu.
In the Admin menu, click Communication Services .
In the SSH Properties area, update the following properties:
Name
SSH Enabled
SSH Port field check box
Description
Whether SSH is enabled on the Cisco IMC.
The port to use for secure shell access. The default is 22.
SSH Timeout field
Max Sessions field
Active Sessions field
The number of seconds to wait before the system considers an SSH request to have timed out.
Enter an integer between 60 and 10,800. The default is 1,800 seconds.
The maximum number of concurrent SSH sessions allowed on the Cisco
IMC.
This value may not be changed.
The number of SSH sessions currently running on the Cisco IMC.
Click Save Changes .
Configuring XML API
XML API for Cisco IMC
The Cisco Cisco IMC XML application programming interface (API) is a programmatic interface to Cisco
IMC for a C-Series Rack-Mount Server. The API accepts XML documents through HTTP or HTTPS.
For detailed information about the XML API, see Cisco UCS Rack-Mount Servers Cisco IMC XML API
Programmer’s Guide .
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
263
Configuring Communication Services
Enabling the XML API
Enabling the XML API
Before you begin
You must log in as a user with admin privileges to perform this task.
Procedure
Step 1
Step 2
Step 3
Step 4
In the Navigation pane, click the Admin menu.
In the Admin menu, click Communication Services .
In the XML API Properties area, update the following properties:
Name
XML API Enabled
Max Sessions field check box
Description
Whether API access is allowed on this server.
The maximum number of concurrent API sessions allowed on the Cisco
IMC.
This value may not be changed.
Active Sessions field The number of API sessions currently running on the Cisco IMC.
Click Save Changes .
Enabling Redfish
Before you begin
You must be logged in as admin to perform this action.
Procedure
Step 1
Step 2
Step 3
In the Navigation pane, click the Admin tab.
On the Admin tab, click Communications Services .
In the Redfish Properties area, update the following properties:
Name
XML API Enabled check box
Description
Whether API access is allowed on this server.
Max Sessions field
Active Sessions field
The maximum number of concurrent API sessions allowed on the Cisco
IMC.
This value may not be changed.
The number of API sessions currently running on the Cisco IMC.
264
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Configuring Communication Services
Configuring IPMI
Step 4 Click Save Changes .
Configuring IPMI
IPMI Over LAN
Intelligent Platform Management Interface (IPMI) defines the protocols for interfacing with a service processor embedded in a server platform. This service processor is called a Baseboard Management Controller (BMC) and resides on the server motherboard. The BMC links to a main processor and other on-board elements using a simple serial bus.
During normal operations, IPMI lets a server operating system obtain information about system health and control system hardware. For example, IPMI enables the monitoring of sensors, such as temperature, fan speeds and voltages, for proactive problem detection. If server temperature rises above specified levels, the server operating system can direct the BMC to increase fan speed or reduce processor speed to address the problem.
Configuring IPMI over LAN
Configure IPMI over LAN when you want to manage the Cisco IMC with IPMI messages.
Note • If you would want to run IPMI commands without issuing an encryption key, set the Encryption Key field in Cisco IMC to any even number of zeroes and save. This allows you to issue IPMI commands without including an encryption key.
• You are only allowed a maximum of four concurrent IPMI sessions.
Before you begin
You must log in as a user with admin privileges to perform this task.
Procedure
Step 1
Step 2
Step 3
In the Navigation pane, click the Admin menu.
In the Admin menu, click Communication Services .
In the IPMI over LAN Properties area, update the following properties for BMC 1, BMC 2, CMC 1, or
CMC 2:
Name
Enabled check box
Description
Whether IPMI access is allowed on this server.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
265
Configuring Communication Services
Configuring SNMP
Step 4
Name Description
Privilege Level Limit drop-down list
The highest privilege level that can be assigned to an IPMI session on this server. This can be one of the following:
• read-only —IPMI users can view information but cannot make any changes. If you select this option, IPMI users with the
"Administrator", "Operator", or "User" user roles can only create read-only IPMI sessions, regardless of their other IPMI privileges.
• user —IPMI users can perform some functions but cannot perform administrative tasks. If you select this option, IPMI users with the
"Administrator" or "Operator" user role can create user and read-only sessions on this server.
• admin —IPMI users can perform all available actions. If you select this option, IPMI users with the "Administrator" user role can create admin, user, and read-only sessions on this server.
Encryption Key
Randomize field button
Click Save Changes .
The IPMI encryption key to use for IPMI communications.
Enables you to change the IPMI encryption key to a random value.
Configuring SNMP
SNMP
The Cisco UCS C-Series Rack-Mount Servers support the Simple Network Management Protocol (SNMP) for viewing server configuration and status and for sending fault and alert information by SNMP traps. For information on Management Information Base (MIB) files supported by Cisco IMC, see the MIB Quick
Reference for Cisco UCS at this URL: http://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/sw/mib/ b-series/b_UCS_MIBRef.html
.
Beginning with release 4.1(3b), Cisco IMC introduces enhanced authentication protocol for SNMP v3 version.
SNMP v3 users cannot be added with DES security protocol.
Cisco IMC GUI displays a warning when you select an existing v3 version with unsupported security level, authentication type, or privacy type. You may select and modify the user details.
Configuring SNMP Properties
Before you begin
You must log in as a user with admin privileges to perform this task.
266
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Configuring Communication Services
Configuring SNMP Properties
Procedure
Step 1
Step 2
Step 3
Step 4
In the Navigation pane, click the Admin menu.
In the Admin menu, click Communication Services .
In the Communications Services pane, click the SNMP tab.
In the SNMP Properties area, update the following properties:
Name
SNMP Enabled check box
Description
Whether this server sends SNMP traps to the designated host.
Note After you check this check box, you need to click Save
Changes before you can configure SNMP users or traps.
SNMP Port field
Access Community String field
SNMP Community Access drop-down list
The port on which Cisco IMC SNMP agent runs.
Enter an SNMP port number within the range 1 to 65535. The default port number is 161.
Note The port numbers that are reserved for system calls, such as
22,23,80,123,443,623,389,636,3268,3269 and 2068, cannot be used as an SNMP port.
The default SNMP v1 or v2c community name Cisco IMC includes on any SNMP get operations.
Enter a string up to 18 characters.
This can be one of the following:
• Disabled — This option blocks access to the information in the inventory tables.
• Limited — This option provides partial access to read the information in the inventory tables.
• Full — This option provides full access to read the information in the inventory tables.
Trap Community String
System Contact field field
Note SNMP Community Access is applicable only for SNMP v1 and v2c users.
The name of the SNMP community group used for sending SNMP trap to other devices.
Enter a string up to 18 characters.
Note This field is visible only for SNMP v1 and v2c users. SNMP v3 version need to use SNMP v3 credentials.
The system contact person responsible for the SNMP implementation.
Enter a string up to 254 characters, such as an email address or a name and telephone number.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
267
Configuring Communication Services
Configuring SNMP Trap Settings
Name
System Location field
SNMP Input Engine ID field
SNMP Engine ID field
Description
The location of the host on which the SNMP agent (server) runs.
Enter a string up to 254 characters.
User-defined unique identification of the static engine.
Unique string to identify the device for administration purpose. This is generated from the SNMP Input Engine ID if it is already defined, else it is derived from the BMC serial number.
Step 5 Click Save Changes .
What to do next
Configure SNMP trap settings.
Configuring SNMP Trap Settings
Before you begin
You must log in as a user with admin privileges to perform this task.
Procedure
Step 1
Step 2
Step 3
Step 4
Step 5
Step 6
In the Navigation pane, click the Admin menu.
In the Admin menu, click Communication Services .
In the Communications Services pane, click the SNMP tab.
Click on Trap Destinations tab.
In the Trap Destinations area, you can perform one of the following:
• Select an existing user from the table and click Modify Trap .
• Click Add Trap to create a new user.
Note If the fields are not highlighted, select Enabled .
In the Trap Details dialog box, complete the following fields:
Name
ID field
Description
The trap destination ID. This value cannot be modified.
Enabled check box If checked, then this trap is active on the server.
268
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Configuring Communication Services
Sending a Test SNMP Trap Message
Step 7
Step 8
Name
Version drop-down list
Trap Type
User radio button drop-down list
Description
The SNMP version and model used for the trap. This can be one of the following:
• V2
• V3
The type of trap to send. This can be one of the following:
• Trap : If this option is chosen, the trap will be sent to the destination but you do not receive any notifications.
• Inform : You can choose this option only for V2 users. If chosen, you will receive a notification when a trap is received at the destination.
The drop-down list displays all available users, select a user from the list.
Note While Configuring SNMP v3 version, SNMP users with
Encryption Method set as DES are not displayed in the drop-down list.
Trap Destination Address field
Port
Address to which the SNMP trap information is sent. You can set an
IPv4 or IPv6 address or a domain name as the trap destination.
The port the server uses to communicate with the trap destination.
Enter a trap destination port number within the range 1 to 65535.
Click Save Changes .
If you want to delete a trap destination, select the row and click Delete .
Click OK in the delete confirmation prompt.
Sending a Test SNMP Trap Message
Before you begin
You must log in as a user with admin privileges to perform this task.
Procedure
Step 1
Step 2
Step 3
Step 4
In the Navigation pane, click the Admin menu.
In the Admin menu, click Communication Services .
In the Communication Services pane, click SNMP .
In the Trap Destinations area, select the row of the desired SNMP trap destination.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
269
Configuring Communication Services
Managing SNMP Users
Step 5 Click Send SNMP Test Trap .
An SNMP test trap message is sent to the trap destination.
Note The trap must be configured and enabled in order to send a test message.
Managing SNMP Users
Before you begin
• You must log in as a user with admin privileges to perform this task.
• SNMP must be enabled.
Procedure
Step 1
Step 2
Step 3
Step 4
Step 5
In the Navigation pane, click the Admin menu.
In the Admin menu, click Communication Services .
In the Communications Services pane, click the SNMP tab.
In the User Settings area, update the following properties:
Name
Add button
Description
Click an available row in the table then click this button to add a new
SNMP user.
Modify button
Delete button
Select the user you want to change in the table then click this button to modify the selected SNMP user.
Select the user you want to delete in the table then click this button to delete the selected SNMP user.
ID column
Name column
Auth Type column
Privacy Type column
The system-assigned identifier for the SNMP user.
The SNMP user name.
The user authentication type.
The user privacy type.
Click Save Changes .
270
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Configuring Communication Services
Configuring SNMP Users
Configuring SNMP Users
Before you begin
• You must log in as a user with admin privileges to perform this task.
• SNMP must be enabled.
Procedure
Step 1
Step 2
Step 3
Step 4
Step 5
In the Navigation pane, click the Admin menu.
In the Admin menu, click Communication Services .
In the Communications Services pane, click the SNMP tab.
In the User Settings area, perform one of the following actions:
• Select an existing user from the table and click Modify User .
• Select a row in the Users area and click Add User to create a new user.
In the SNMP User Details dialog box, update the following properties:
Name
ID field
Description
The unique identifier for the user. This field cannot be changed.
Name field The SNMP username.
Enter between 1 and 31 characters or spaces.
Note Cisco IMC automatically trims leading or trailing spaces.
Security Level drop-down list The security level for this user. This can be one of the following:
• no auth, no priv —The user does not require an authorization or privacy password.
• auth, no priv —The user requires an authorization password but not a privacy password. If you select this option, Cisco IMC enables the Auth fields described below.
• auth, priv —The user requires both an authorization password and a privacy password. If you select this option, Cisco IMC enables the Auth and Privacy fields.
Auth Type drop-down The authorization type. This can be one of the following:
• MD5
• SHA
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
271
Configuring Communication Services
Configuring a Server to Send Email Alerts Using SMTP
Step 6
Step 7
Name
Auth Password field
Confirm Auth Password
Privacy Type drop-down field
Description
The authorization password for this SNMP user.
Enter between 8 and 64 characters or spaces.
Note Cisco IMC automatically trims leading or trailing spaces.
The authorization password again for confirmation purposes.
The privacy type. This can be one of the following:
• AES
Note For a v3 version, only AES option is available.
Privacy Password field The privacy password for this SNMP user.
Enter between 8 and 64 characters or spaces.
Note Cisco IMC automatically trims leading or trailing spaces.
Confirm Privacy Password field The authorization password again for confirmation purposes.
Click Save Changes .
If you want to delete a user, select the user and click Delete User .
Click OK in the delete confirmation prompt.
Configuring a Server to Send Email Alerts Using SMTP
The Cisco IMC supports email-based notification of server faults to recipients without relying on the SNMP.
The system uses the Simple Mail Transfer Protocol (SMTP) to send server faults as email alerts to the configured
SMTP server.
A maximum of four recipients is supported.
Configuring SMTP Server For Receiving Email Alerts
Configure the SMTP properties and add email recipients on the Mail Alert tab to receive email notifications for server faults.
Before you begin
You must log in as a user with admin privileges to perform this task.
Procedure
Step 1
272
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Configuring Communication Services
Configuring SMTP Server For Receiving Email Alerts
Step 2
Step 3
Step 4
In the Admin menu, click Communication Services .
In the Communications Services pane, click the Mail Alert tab.
In the SMTP Properties area, update the following properties.
Name
SMTP Enabled check box
Description
If checked, it enables the SMTP service.
SMTP Server Address field
SMTP Port field
Allows you to enter the SMTP server address.
Allows you to enter the SMTP port number. The default port number is 25.
SMTP From Address Allows you to set the From address of the SMTP mail alerts that are sent. The email address that you enter in this field will be displayed as the from address (mail received from address) of all the SMTP mail alerts that you receive.
Note This is an optional field. If you do not enter an email address in this field, by default the server hostname ID is displayed as the from address (mail received from address).
Step 5 In the SMTP Recipients area, do the following: a) Click the Add (+) button to add the email recipients to whom notifications should be sent. Enter the email
ID and click Save .
To delete an email recipient, select the email recipient and click the Delete (X) button.
b) Minimum Severity to Report drop-down list allows you to choose the minimum severity level for receiving the email alert. This can be one of the following:
• Condition
• Warning
• Minor
• Major
• Critical
If you choose a minimum severity level, the mail alerts are sent for that level and the other higher severity levels. For example, if you choose 'Minor' as the minimum severity level, you will receive email alerts for the minor, major, and critical fault events.
c) Click Send Test Mail to check whether the email recipient you added is reachable.
If the email address and the SMTP settings are valid, a confirmation pop-up window appears with the message that an email has been sent. If the settings are not valid, a confirmation pop-up window appears with the message that no email has been sent. The Reachability column indicates whether test mails have been sent successfully to the email recipient. The Reachability column has one of the following values:
• Yes (if the test mail has been sent successfully)
• No (if the test mail has not been sent successfully)
• na (if no test mail has been sent)
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
273
Configuring Communication Services
Adding SMTP Email Recipients
Step 6 Click Save Changes .
Troubleshooting
The following table describes troubleshooting suggestions for SMTP mail alert configuration issues (when the reachability status is No ) that may appear in the Cisco IMC logs:
Issue Suggested Solution
Timeout was reached
Couldn't resolve host name
Couldn't connect to server
Failed sending data to the peer
This could occur when you are not able to reach the configured SMTP
IP address. Enter a valid IP address.
This could occur when you are not able to reach the configured SMTP domain name. Enter a valid domain name.
This could occur when the SMTP IP or domain name or port number is/are incorrectly configured. Enter valid configuration details.
This could occur when the an invalid recipient email ID is configured.
Enter a valid email ID.
Adding SMTP Email Recipients
Add email recipients on the Mail Alert tab to receive email notifications for server faults.
Before you begin
• You must log in as a user with admin privileges to perform this task.
• Configure the SMTP server properties in the SMTP Properties area. See
Receiving Email Alerts, on page 272
Procedure
Step 1
Step 2
Step 3
Step 4
In the Navigation pane, click the Admin menu.
In the Admin menu, click Communication Services .
In the Communications Services pane, click the Mail Alert tab.
In the SMTP Recipients area, do the following: a) Click the Add (+) button to add the email recipients to whom notifications should be sent. Enter the email
ID and click Save .
b) Minimum Severity to Report drop-down list allows you to choose the minimum severity level for receiving the email alert. This can be one of the following:
• Condition
• Warning
• Minor
• Major
274
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Configuring Communication Services
Adding SMTP Email Recipients
• Critical
If you choose a minimum severity level, the mail alerts are sent for that level and the other higher severity levels. For example, if you choose 'Minor' as the minimum severity level, you will receive email alerts for the minor, major, and critical fault events.
c) Click Send Test Mail to check whether the email recipient you added is reachable.
If the email address and the SMTP settings are valid, a confirmation pop-up window appears with the message that an email has been sent. If the settings are not valid, a confirmation pop-up window appears with the message that no email has been sent. The Reachability column indicates whether test mails have been sent successfully to the email recipient. The Reachability column has one of the following values:
• Yes (if the test mail has been sent successfully)
• No (if the test mail has not been sent successfully)
• na (if no test mail has been sent)
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
275
Adding SMTP Email Recipients
Configuring Communication Services
276
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
C H A P T E R
14
Managing Certificates and Server Security
This chapter includes the following sections:
•
Managing the Server Certificate, on page 277
•
Generating a Certificate Signing Request, on page 278
•
Creating a Self-Signed Certificate, on page 280
•
Creating a Self-Signed Certificate Using Windows, on page 282
•
Uploading a Server Certificate, on page 283
•
Managing the External Certificate, on page 284
•
Key Management Interoperability Protocol, on page 288
•
FIPS 140-2 Compliance in Cisco IMC, on page 305
Managing the Server Certificate
You can generate a certificate signing request (CSR) to obtain a new certificate, and you can upload the new certificate to the Cisco IMC to replace the current server certificate. The server certificate may be signed either by a public Certificate Authority (CA), such as Verisign, or by your own certificate authority. The generated certificate key length is 2048 bits.
Note Before performing any of the following tasks in this chapter, ensure that the Cisco IMC time is set to the current time.
Procedure
Step 1
Step 2
Step 3
Generate the CSR from the Cisco IMC.
Submit the CSR file to a certificate authority that will issue and sign your certificate. If your organization generates its own self-signed certificates, you can use the CSR file to generate a self-signed certificate.
Upload the new certificate to the Cisco IMC.
Note The uploaded certificate must be created from a CSR generated by the Cisco IMC. Do not upload a certificate that was not created by this method.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
277
Managing Certificates and Server Security
Generating a Certificate Signing Request
Generating a Certificate Signing Request
Note Do not use special characters (For example ampersand ( & )) in the Common Name and Organization Unit fields.
Before you begin
• You must log in as a user with admin privileges to configure certificates.
• Ensure that the Cisco IMC time is set to the current time.
Procedure
Step 1
Step 2
Step 3
Step 4
In the Navigation pane, click the Admin menu.
In the Admin menu, click Security Management .
In the Actions area, click the Generate New Certificate Signing Request link.
The Generate New Certificate Signing Request dialog box appears.
In the Generate New Certificate Signing Request dialog box, update the following properties:
Name
Common Name field
Subject Alternate Name (SAN)
Description
The fully qualified name of the Cisco IMC.
By default the CN of the servers appears in CXXX-YYYYYY format, where XXX is the model number and YYYYYY is the serial number of the server.
When you upgrade to latest version, CN is retained as is.
You can now provide additional input parameter for Subject Alternate
Name. This allows various values to be associated using the subject field of the certificate.
The various options of SAN includes:
• DNS name
• IP address
• Uniform Resource Identifier (URI)
Note This field is optional. You can configure any number of SAN instances of each type, but all together the instances count must not exceed 10.
Organization Name field The organization requesting the certificate.
278
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Managing Certificates and Server Security
Generating a Certificate Signing Request
Name
Organization Unit
Locality field
State Name field
Country Code
Email field field drop-down list
Signature Algorithm
Description
The organizational unit.
The city or town in which the company requesting the certificate is headquartered.
The state or province in which the company requesting the certificate is headquartered.
The country in which the company resides.
The email contact at the company.
Allows you to select the signature algorithm for generating certificate signing request. This can be one of the following:
• SHA384
• SHA1
• SHA256
• SHA512
Challenge Password check box
The default signature algorithm selected for generating certificate signing request is SHA384.
A Challenge Password is to be embedded in the Certificate Signing
Request (CSR) dialog box, which the issuer Certificate Authority (CA) uses to authenticate the certificate.
If Challenge Password option is selected, then Challenge Password
String will be populated for the user to enter the valid password string.
Note The user has an option not to select the Challenge Password in which case the Challenge Password String is not populated. However, the user can proceed with generating the CSR successfully.
String Mask drop-down list This sets a mask for permitted string types in Certificate Signing Request
(CSR) dialog box. This option masks out the use of certain string types in certain fields. The string types are as follows:
• Default : Uses PrintableString, T61String, BMPString.
• pkix : Uses PrintableString, BMPString.
• utf8only : Uses only UTF8Strings.
• nombstr : Uses PrintableString, T61String (no BMPStrings or
UTF8Strings).
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
279
Managing Certificates and Server Security
Creating a Self-Signed Certificate
Step 5
Step 6
Name Description
Self Signed Certificate check box Generates a Self Signed Certificate.
Warning
Note
After successful certificate generation, the Cisco IMC Web
GUI restarts. Communication with the management controller may be lost momentarily and you will need to re-login.
If enabled, CSR is generated, signed and uploaded automatically.
Note If Self-signed certificate is enabled, ignore steps 5 and 6.
Click Generate CSR .
The Opening csr.txt
dialog box appears.
Perform any one of the following steps to manage the CSR file, csr.txt: a) Click Open With to view csr.txt.
b) Click Save File and then click OK to save csr.txt to your local machine.
What to do next
• Submit the CSR file to a certificate authority that will issue and sign your certificate. If your organization generates its own self-signed certificates, you can use the CSR file to generate a self-signed certificate.
• Ensure that the certificate is of type Server .
Creating a Self-Signed Certificate
As an alternative to using a public Certificate Authority (CA) to generate and sign a server certificate, you can operate your own CA and sign your own certificates. This section shows commands for creating a CA and generating a server certificate using the OpenSSL certificate server running on Linux. For detailed information about OpenSSL, see http://www.openssl.org
.
Note These commands are to be entered on a Linux server with the OpenSSL package, not in the Cisco IMC.
Before you begin
• Obtain and install a certificate server software package on a server within your organization.
• Ensure that the Cisco IMC time is set to the current time.
280
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Managing Certificates and Server Security
Creating a Self-Signed Certificate
Procedure
Step 1
Step 2
Step 3
Step 4
Step 5
Step 6
Command or Action
openssl genrsa -out CA_keyfilename keysize
Example:
# openssl genrsa -out ca.key 2048
Purpose
This command generates an RSA private key that will be used by the CA.
Note To allow the CA to access the key without user input, do not use the
-des3 option for this command.
The specified file name contains an RSA key of the specified key size.
openssl req -new -x509 -days numdays -key
CA_keyfilename -out CA_certfilename
Example:
# openssl req -new -x509 -days 365 -key ca.key -out ca.crt
This command generates a new self-signed certificate for the CA using the specified key.
The certificate is valid for the specified period.
The command prompts the user for additional certificate information.
The certificate server is an active CA.
echo "nsCertType = server" > openssl.conf
Example:
# echo "nsCertType = server" > openssl.conf
This command adds a line to the OpenSSL configuration file to designate the certificate as a server-only certificate. This designation is a defense against a man-in-the-middle attack, in which an authorized client attempts to impersonate the server.
The OpenSSL configuration file openssl.conf
contains the statement "nsCertType = server".
openssl x509 -req -days numdays -in
CSR_filename -CA CA_certfilename -set_serial
04 -CAkey CA_keyfilename -out
server_certfilename -extfile openssl.conf
This command directs the CA to use your CSR file to generate a server certificate.
Your server certificate is contained in the output file.
Example:
# openssl x509 -req -days 365 -in csr.txt
-CA ca.crt -set_serial 04
-CAkey ca.key -out myserver05.crt
-extfile openssl.conf
openssl x509 -noout -text -purpose -in <cert file>
Verifies if the generated certificate is of type
Server .
Example: openssl x509 -noout -text -purpose -in
<cert file>
Note If the values of the fields Server
SSL and Netscape SSL server are not yes, ensure that openssl.conf is configured to generate certificates of type server.
(Optional) If the generated certificate does not have the correct validity dates, ensure the Cisco
IMC time is set to the current time, and
Certificate with the correct validity dates is created.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
281
Managing Certificates and Server Security
Creating a Self-Signed Certificate Using Windows
Command or Action regenerate the certificate by repeating steps 1 through 5.
Purpose
Example
This example shows how to create a CA and to generate a server certificate signed by the new CA.
These commands are entered on a Linux server running OpenSSL.
# /usr/bin/openssl genrsa -out ca.key 2048
Generating RSA private key, 2048 bit long modulus
.............++++++
.....++++++ e is 65537 (0x10001)
# /usr/bin/openssl req -new -x509 -days 365 -key ca.key -out ca.crt
You are about to be asked to enter information that will be incorporated into your certificate request.
What you are about to enter is what is called a Distinguished Name or a DN.
There are quite a few fields but you can leave some blank
For some fields there will be a default value,
If you enter '.', the field will be left blank.
-----
Country Name (2 letter code) [GB]: US
State or Province Name (full name) [Berkshire]: California
Locality Name (eg, city) [Newbury]: San Jose
Organization Name (eg, company) [My Company Ltd]: Example Incorporated
Organizational Unit Name (eg, section) []: Unit A
Common Name (eg, your name or your server's hostname) []: example.com
Email Address []: [email protected]
# echo "nsCertType = server" > openssl.conf
# /usr/bin/openssl x509 -req -days 365 -in csr.txt -CA ca.crt -set_serial 01
-CAkey ca.key -out server.crt -extfile openssl.conf
Signature ok subject=/C=US/ST=California/L=San Jose/O=Example Inc./OU=Unit
A/CN=example.com/[email protected]
Getting CA Private Key
#
What to do next
Upload the new certificate to the Cisco IMC.
Creating a Self-Signed Certificate Using Windows
Before you begin
• You must log in as a user with admin privileges to configure certificates.
• Ensure that the Cisco IMC time is set to the current time.
282
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Managing Certificates and Server Security
Uploading a Server Certificate
Procedure
Step 1
Step 2
Step 3
Step 4
Step 5
Step 6
Open IIS Manager and navigate to the level you want to manage.
In the Features area, double-click Server Certificate .
In the Action pane, click Create Self-Signed Certificate .
On the Create Self-Signed Certificate window, enter name for the certificate in the Specify a friendly name for the certificate field.
Click Ok .
(Optional) If the generated certificate does not have the correct validity dates, ensure the Cisco IMC time is set to the current time, and regenerate the certificate by repeating steps 1 through 5.
Certificate with the correct validity dates is created.
Uploading a Server Certificate
You can either browse and select the certificate to be uploaded to the server or copy the entire content of the signed certificate and paste it in the Paste certificate content text field and upload it.
Before you begin
• You must log in as a user with admin privileges to upload a certificate.
• The certificate file to be uploaded must reside on a locally accessible file system.
• Ensure that the generated certificate is of type server.
• The following certificate formats are supported:
• .crt
• .cer
• .pem
Note You must first generate a CSR using the Cisco IMC Certificate Management menu, and you must use that
CSR to obtain the certificate for uploading. Do not upload a certificate that was not obtained by this method.
Procedure
Step 1
Step 2
Step 3
In the Navigation pane, click the Admin menu.
In the Admin menu, click Certificate Management .
In the Actions area, click Upload Server Certificate .
The Upload Certificate dialog box appears.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
283
Managing Certificates and Server Security
Managing the External Certificate
Step 4
Step 5
In the Upload Certificate dialog box, update the following properties:
Name
File field
Browse button
Description
The certificate file you want to upload.
Opens a dialog box that allows you to navigate to the appropriate certificate file.
Paste Certificate content radio button
Opens a dialog box that allows you to copy the entire content of the signed certificate and paste it in the Paste certificate content text field.
Note Ensure the certificate is signed before uploading.
Allows you to upload the certificate.
Upload Certificate button
Click Upload Certificate .
Managing the External Certificate
Prior to the 4.1.2 release, you can generate a certificate signing request (CSR) and upload a new server certificate to Cisco IMC. Release 4.1.2 onwards, you can also upload a wildcard or an external certificate and an external private key, in addition to a server certificate. Unlike a server certificate, you could upload and use the same external certificate and key pair for multiple Cisco IMC servers.
1.
Upload the external certificate and external private key to Cisco IMC.
2.
Activate the uploaded certificate.
On activation, the new certificate and private key pair replaces the existing certificate and key pair in
Cisco IMC.
Uploading an External Certificate
Before you begin
• You must log in as a user with admin privileges.
• The certificate file to be uploaded must reside on a locally accessible file system.
• The following certificate formats are supported:
• .crt
• .cer
• .pem
284
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Managing Certificates and Server Security
Uploading an External Certificate
Note • Cisco IMC supports external private key size of 2048 bits and 4096 bits in Cisco UCS C-Series M4 servers.
• Cisco IMC supports external private key size of 2048 bits, 4096 bits and 8192 bits in Cisco UCS C-Series
M5 servers.
Procedure
Step 1
Step 2
Step 3
Step 4
In the Navigation pane, click the Admin tab.
On the Admin tab, click Certificate Management .
In the Actions area, click Upload External Certificate .
The Upload External Certificate dialog box appears.
In the Upload External Certificate dialog box, select the appropriate options and enter the relevant details:
• Upload from remote location : Select this radio button to upload an external certificate from a remote location.
Name
Upload from remote location field
Description
Select from one of the following protocols:
• TFTP
• FTP
• SCP
• SFTP
• HTTP
Note If you select FTP, SCP or SFTP, you will be prompted to enter your username and password.
Server IP/ Hostname button
Path and Filename
Enter the remote server IP address or hostname.
Enter the filepath on the remote server from where you want to upload the external certificate along with the filename.
Note The maximum file size supported for upload using this option is:
• Up to 8 KB in Cisco UCS C-Series M5 servers
• Up to 4 KB in Cisco UCS C-Series M4 servers
Username
Password
Enter the user name for your remote server.
Password for your remote server.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
285
Managing Certificates and Server Security
Uploading an External Private Key
• Upload through browser Client : Select this radio button to upload an external certificate using a browser client.
Click Browse and navigate to the location from where you want to upload the external certificate.
Note The maximum file size supported for upload using this option is up to 5 KB in:
• Cisco UCS C-Series M4 servers
• Cisco UCS C-Series M5 servers
• Paste External Certificate Content : Select this radio button to paste the external certificate details directly in the dialog box.
Note The maximum file size supported for upload using this option is:
• Up to 8 KB in Cisco UCS C-Series M5 servers
• Up to 4 KB in Cisco UCS C-Series M4 servers
Step 5 Click Upload to upload the external certificate.
What to do next
Upload the external private key and then activate the uploaded external certificate.
Important After you upload the external certificate and the external private key, the Activate External Certificate tab is enabled. Select Activate External Certificate to activate the uploaded external certificate.
Activating the uploaded certificate replaces the existing certificate and key pair, and disconnects any existing
HTTPS and SSH sessions.
Uploading an External Private Key
Before you begin
• You must log in as a user with admin privileges to upload an external private key.
• Ensure that you have uploaded an external certificate.
Note • Cisco IMC supports external private key size of 2048 bits and 4096 bits in Cisco UCS C-Series M4 servers.
• Cisco IMC supports external private key size of 2048 bits, 4096 bits and 8192 bits in Cisco UCS C-Series
M5 servers.
286
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Managing Certificates and Server Security
Uploading an External Private Key
Procedure
Step 1
Step 2
Step 3
Step 4
In the Navigation pane, click the Admin tab.
On the Admin tab, click Certificate Management .
In the Actions area, click Upload External Private Key .
The Upload External Private Key dialog box appears.
In the Upload External Private Key dialog box, select the appropriate options and enter the relevant details:
• Upload from remote location : Select this radio button to upload an external certificate from a remote location.
Name
Upload from remote location field
Description
Select from one of the following protocols:
• SFTP
• SCP
Server IP/ Hostname button
Path and Filename
Enter the remote server IP address or hostname.
Enter the filepath on the remote server from where you want to upload the external private key along with the filename.
Note The maximum file size supported for upload using this option is:
• Up to 8 KB in Cisco UCS C-Series M5 servers
• Up to 4 KB in Cisco UCS C-Series M4 servers
Username
Password
Enter the user name for your remote server.
Password for your remote server.
• Upload through browser Client : Select this radio button to upload an external private key using a browser client.
Click Browse and navigate to the location from where you want to upload the external private key.
Note The maximum file size supported for upload using this option is up to 5 KB in:
• Cisco UCS C-Series M4 servers
• Cisco UCS C-Series M5 servers
• Paste External Private Key Content : Select this radio button to paste the external private key details directly in the dialog box.
Note The maximum file size supported for upload using this option is:
• Up to 8 KB in Cisco UCS C-Series M5 servers
• Up to 4 KB in Cisco UCS C-Series M4 servers
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
287
Managing Certificates and Server Security
Activating the External Certificate
Step 5 Click Upload to upload the external private key.
What to do next
After uploading the external certificate and external private key, activate the uploaded external certificate.
Important After you upload the external certificate and the external private key, the Activate External Certificate tab is enabled. Select Activate External Certificate to activate the uploaded external certificate.
Activating the uploaded certificate replaces the existing certificate and key pair, and disconnects any existing
HTTPS and SSH sessions.
Activating the External Certificate
Before you begin
• You must log in as a user with admin privileges to activate an external certificate.
• Ensure that you have uploaded the external certificate and external private key.
Procedure
Step 1
Step 2
Step 3
In the Navigation pane, click the Admin tab.
On the Admin tab, click Certificate Management .
After uploading the external certificate and the private key, the Activate External Certificate tab is enabled in the Actions area.
Click Activate External Certificate .
Note Activating the external certificate overwrites any existing certificate and key pair, and disconnects any existing HTTPS and SSH sessions.
Key Management Interoperability Protocol
Key Management Interoperability Protocol (KMIP) is a communication protocol that defines message formats to handle keys or classified data on a key management server. KMIP is an open standard and is supported by several vendors. Key management involves multiple interoperable implementations, so a KMIP client works effectively with any KMIP server.
Self-Encrypting Drives(SEDs) contain hardware that encrypts incoming data and decrypts outgoing data in realtime. A drive or media encryption key controls this function. However, the drives need to be locked in order to maintain security. A security key identifier and a security key (key encryption key) help achieve this goal. The key identifier provides a unique ID to the drive.
288
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Managing Certificates and Server Security
Viewing Secure Key Management Settings
Different keys have different usage requirements. Currently, the responsibility of managing and tracking local keys lies primarily with the user, which could result in human error. The user needs to remember the different keys and their functions, which could prove to be a challenge. KMIP addresses this area of concern to manage the keys effectively without human involvement.
Viewing Secure Key Management Settings
Procedure
Step 1
Step 2
Step 3
Step 4
Step 5
Step 6
In the Navigation pane, click the Admin menu.
In the Admin menu, click Security Management .
In the Security Management pane, click Secure Key Management .
In the Work pane, review the following field:
Name
Enable Secure Key Management check box
Description
If checked, allows you to enable the secure key management feature.
In the Actions Area, review the following fields:
Name
Download Root CA Certificate
Export Root CA Certificate
Delete Root CA Certificate
Download Client Certificate
Export Client Certificate
Delete Client Certificate
Export Client Private Key link link link link
Download Client Private Key link link link link
Delete Client Private Key link
Delete KMIP Login link
In the KMIP Servers Area, review the following fields:
Description
This allows you to download the root CA certificate to Cisco IMC.
This allows you to export the downloaded root CA certificate to a local file or remote server.
This allows you to delete the root CA certificate.
This allows you to download the client certificate to
Cisco IMC.
This allows you to export the downloaded client certificate to a local file or remote server.
This allows you to delete the client certificate.
This allows you to download the client private key to
Cisco IMC.
This allows you to export the downloaded root CA certificate to local file or remote server.
This allows you to delete the root CA certificate.
This allows you to delete the KMIP login details.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
289
Managing Certificates and Server Security
Viewing Secure Key Management Settings
Step 7
Step 8
Step 9
Name
ID field
IP Address field
Port field
Timeout
Delete field button
Test Connection button
Description
ID for the KMIP server configuration.
IP address of the KMIP server.
Communication port to the KMIP server.
Time period that Cisco IMC waits for a response from the KMIP server.
Deletes the KMIP server configuration.
Tests whether or not the KMIP connection was successful.
In the KMIP Root CA Certificate Area, review the following fields:
Name
Server Root CA Certificate
Download Status field field
Description
Indicates the availability of the root CA certificate.
This field displays the status of the root CA certificate download.
Download Progress field
Export Status field
Export Progress field
This field displays the progress of the root CA certificate download.
This field displays the status of the root CA certificate export.
This field displays the progress of the root CA certificate export.
In the KMIP Client Certificate Area, review the following fields:
Name
Client Certificate field
Description
Indicates the availability of the client certificate.
Download Status field
Download Progress
Export Status field
Export Progress field field
This field displays the status of the client certificate download.
This field displays the progress of the client certificate download.
This field displays the status of the client certificate export.
This field displays the progress of the client certificate export.
In the KMIP Login Details Area, review the following fields:
290
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Managing Certificates and Server Security
Creating a Client Private Key and Client Certificate for KMIP Configuration
Step 10
Name
Use KMIP Login check box
Login name to KMIP Server field
Password to KMIP Server field
Change Password check box
New Password field
Confirm Password field
Description
Allows you to choose whether or not to use KMIP login details.
User name of the KMIP server.
Password of the KMIP server.
Allows you to change the KMIP password.
Allows you to enter the new password that you want to assign to the KMIP server.
Note This option is only visible when you enable the Change Password check box.
Enter the new password again in this field.
Note This option is only visible when you enable the Change Password check box.
In the KMIP Client Private Key Area, review the following fields:
Name
Client Private Key field
Description
Indicates the availability of the client private key.
Download Status field
Download Progress
Export Status field
Export Progress field field
This field displays the status of the client private key download.
This field displays the progress of the client private key download.
This field displays the status of the client private key export.
This field displays the progress of the client private key export.
Creating a Client Private Key and Client Certificate for KMIP Configuration
As an alternative to using a public Certificate Authority (CA) to generate and sign a server certificate, you can operate your own CA and sign your own certificates. This section shows commands for creating a CA and generating a server certificate using the OpenSSL certificate server running on Linux. For detailed information about OpenSSL, see http://www.openssl.org
.
Note These commands are to be entered on a Linux server with the OpenSSL package, not in the Cisco IMC.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
291
Managing Certificates and Server Security
Downloading a Client Certificate
Before you begin
• Obtain and install a certificate server software package on a server within your organization.
• Ensure that the Cisco IMC time is set to the current time.
Procedure
Step 1
Step 2
Step 3
Command or Action Purpose
openssl genrsa -out Client_Privatekeyfilename keysize
This command generates a client private key that will be used to generate the client certificate.
Example:
# openssl genrsa –out client_private.pem
2048
The specified file name contains an RSA key of the specified key size.
openssl req -new -x509 -days numdays -key
Client_Privatekeyfilename -out
Client_certfilename
Example:
# openssl req -new -x509 -key client_private.pem -out client.pem -days
365
This command generates a new self-signed client certificate using the client private key obtained from the previous step. The certificate is valid for the specified period. The command prompts the user for additional certificate information.
A new self-signed client certificate is created.
Obtain the KMIP root CA certificate from the
KMIP server.
Refer to the KMIP vendor documentation for details on obtaining the root CA certificate.
What to do next
Upload the new certificate to the Cisco IMC.
Downloading a Client Certificate
Procedure
Step 1
Step 2
Step 3
Step 4
Step 5
In the Navigation pane, click the Admin menu.
In the Admin menu, click Security Management .
In the Security Management pane, click Secure Key Management .
In the Actions area of the Secure Key Management tab, click Download Client Certificate .
In the Download Client Certificate dialog box, complete these fields:
292
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Managing Certificates and Server Security
Downloading a Client Certificate
Name
Download From Remote
Location radio button
Download Through Browser
Client radio button
Paste Content radio button
Description
Selecting this option allows you to choose the certificate from a remote location and download it. Enter the following details:
• • TFTP Server
• FTP Server
• SFTP Server
• SCP Server
• HTTP Server
Note If you chose SCP or SFTP as the remote server type while performing this action, a pop-up window is displayed with the message Server (RSA) key fingerprint is <server_finger_print _ID> Do you wish to continue?
.
Click Yes or No depending on the authenticity of the server fingerprint.
The fingerprint is based on the host's public key and helps you to identify or verify the host you are connecting to.
• Server IP/Hostname field — The IP address or hostname of the server on which the client certificate file should be stored.
Depending on the setting in the Download Certificate from drop-down list, the name of the field may vary.
• Path and Filename field — The path and filename Cisco IMC should use when downloading the file to the remote server.
• Username field — The username the system should use to log in to the remote server. This field does not apply if the protocol is
TFTP or HTTP.
• Password field — The password for the remote server username.
This field does not apply if the protocol is TFTP or HTTP.
Selecting this option allows you to navigate to the certificate stored on a drive that is local to the computer running the Cisco IMC GUI.
When you select this option, Cisco IMC GUI displays a Browse button that lets you navigate to the file you want to import.
Selecting this option allows you to copy the entire content of the signed certificate and paste it in the Paste Certificate Content text field.
Note Ensure the certificate is signed before uploading.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
293
Managing Certificates and Server Security
Exporting a Client Certificate
Exporting a Client Certificate
Procedure
Step 1
Step 2
Step 3
Step 4
Step 5
In the Navigation pane, click the Admin menu.
In the Admin menu, click Security Management .
In the Security Management pane, click Secure Key Management .
In the Actions area of the Secure Key Management tab, click Export Client Certificate .
In the Export Client Certificate dialog box, complete these fields:
294
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Managing Certificates and Server Security
Name
Export to Remote Location
Exporting a Client Certificate
Description
Selecting this option allows you to choose the certificate from a remote location and export it. Enter the following details:
• • TFTP Server
• FTP Server
• SFTP Server
• SCP Server
• HTTP Server
Note If you chose SCP or SFTP as the remote server type while performing this action, a pop-up window is displayed with the message Server
(RSA) key fingerprint is
<server_finger_print _ID> Do you wish to continue?
. Click Yes or No depending on the authenticity of the server fingerprint.
The fingerprint is based on the host's public key and helps you to identify or verify the host you are connecting to.
• Server IP/Hostname field — The IP address or hostname of the server on which the certificate file should be exported. Depending on the setting in the Download Certificate from drop-down list, the name of the field may vary.
• Path and Filename field — The path and filename Cisco IMC should use when downloading the certificate from the remote server.
• Username field — The username the system should use to log in to the remote server. This field does not apply if the protocol is TFTP or
HTTP.
• Password field — The password for the remote server username. This field does not apply if the protocol is TFTP or HTTP.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
295
Managing Certificates and Server Security
Deleting a Client Certificate
Name
Export to Local File
Description
Selecting this option allows you to choose the certificate stored on a drive that is local to the computer and export it.
Deleting a Client Certificate
Procedure
Step 1
Step 2
Step 3
Step 4
Step 5
In the Navigation pane, click the Admin menu.
In the Admin menu, click Security Management .
In the Security Management pane, click Secure Key Management .
In the Actions area of the Secure Key Management tab, click Delete Client Certificate .
At the prompt, click OK to delete the client certificate, or Cancel to cancel the action.
Downloading a Root CA Certificate
Procedure
Step 1
Step 2
Step 3
Step 4
Step 5
In the Navigation pane, click the Admin menu.
In the Admin menu, click Security Management .
In the Security Management pane, click Secure Key Management .
In the Actions area of the Secure Key Management tab, click Download Root CA Certificate .
In the Download Root CA Certificate dialog box, complete these fields:
296
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Managing Certificates and Server Security
Downloading a Root CA Certificate
Name
Download From Remote
Location radio button
Download Through Browser
Client radio button
Paste Content radio button
Description
Selecting this option allows you to choose the certificate from a remote location and download it. Enter the following details:
• • TFTP Server
• FTP Server
• SFTP Server
• SCP Server
• HTTP Server
Note If you chose SCP or SFTP as the remote server type while performing this action, a pop-up window is displayed with the message Server (RSA) key fingerprint is <server_finger_print _ID> Do you wish to continue?
.
Click Yes or No depending on the authenticity of the server fingerprint.
The fingerprint is based on the host's public key and helps you to identify or verify the host you are connecting to.
• Server IP/Hostname field — The IP address or hostname of the server on which the root CA certificate file should be stored.
Depending on the setting in the Download Certificate from drop-down list, the name of the field may vary.
• Path and Filename field — The path and filename Cisco IMC should use when downloading the file to the remote server.
• Username field — The username the system should use to log in to the remote server. This field does not apply if the protocol is
TFTP or HTTP.
• Password field — The password for the remote server username.
This field does not apply if the protocol is TFTP or HTTP.
Selecting this option allows you to navigate to the certificate stored on a drive that is local to the computer running the Cisco IMC GUI.
When you select this option, Cisco IMC GUI displays a Browse button that lets you navigate to the file you want to import.
Selecting this option allows you to copy the entire content of the signed certificate and paste it in the Paste Certificate Content text field.
Note Ensure the certificate is signed before uploading.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
297
Managing Certificates and Server Security
Exporting a Root CA Certificate
Exporting a Root CA Certificate
Procedure
Step 1
Step 2
Step 3
Step 4
Step 5
In the Navigation pane, click the Admin menu.
In the Admin menu, click Security Management .
In the Security Management pane, click Secure Key Management .
In the Actions area of the Secure Key Management tab, click Export Root CA Certificate .
In the Export Root CA Certificate dialog box, complete these fields:
298
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Managing Certificates and Server Security
Name
Export to Remote Location
Exporting a Root CA Certificate
Description
Selecting this option allows you to choose the certificate from a remote location and export it. Enter the following details:
• • TFTP Server
• FTP Server
• SFTP Server
• SCP Server
• HTTP Server
Note If you chose SCP or SFTP as the remote server type while performing this action, a pop-up window is displayed with the message Server
(RSA) key fingerprint is
<server_finger_print _ID> Do you wish to continue?
. Click Yes or No depending on the authenticity of the server fingerprint.
The fingerprint is based on the host's public key and helps you to identify or verify the host you are connecting to.
• Server IP/Hostname field — The IP address or hostname of the server on which the certificate file should be exported. Depending on the setting in the Download Certificate from drop-down list, the name of the field may vary.
• Path and Filename field — The path and filename Cisco IMC should use when downloading the certificate from the remote server.
• Username field — The username the system should use to log in to the remote server. This field does not apply if the protocol is TFTP or
HTTP.
• Password field — The password for the remote server username. This field does not apply if the protocol is TFTP or HTTP.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
299
Managing Certificates and Server Security
Deleting a Root CA Certificate
Name
Export to Local File
Description
Selecting this option allows you to choose the certificate stored on a drive that is local to the computer and export it.
Deleting a Root CA Certificate
Procedure
Step 1
Step 2
Step 3
Step 4
Step 5
In the Navigation pane, click the Admin menu.
In the Admin menu, click Security Management .
In the Security Management pane, click Secure Key Management .
In the Actions area of the Secure Key Management tab, click Delete Root CA Certificate .
At the prompt, click OK or Cancel to delete the root CA certificate, or cancel the action.
Downloading a Client Private Key
Procedure
Step 1
Step 2
Step 3
Step 4
Step 5
In the Navigation pane, click the Admin menu.
In the Admin menu, click Security Management .
In the Security Management pane, click Secure Key Management .
In the Actions area of the Secure Key Management tab, click Download Client Private Key .
In the Download Client Private Key dialog box, complete these fields:
300
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Managing Certificates and Server Security
Downloading a Client Private Key
Name
Download From Remote
Location radio button
Download Through Browser
Client radio button
Paste Content radio button
Description
Selecting this option allows you to choose the private key from a remote location and download it. Enter the following details:
• • TFTP Server
• FTP Server
• SFTP Server
• SCP Server
• HTTP Server
Note If you chose SCP or SFTP as the remote server type while performing this action, a pop-up window is displayed with the message Server (RSA) key fingerprint is <server_finger_print _ID> Do you wish to continue?
.
Click Yes or No depending on the authenticity of the server fingerprint.
The fingerprint is based on the host's public key and helps you to identify or verify the host you are connecting to.
• Server IP/Hostname field — The IP address or hostname of the server on which the client private key should be stored. Depending on the setting in the Download Certificate From drop-down list, the name of the field may vary.
• Path and Filename field — The path and filename Cisco IMC should use when downloading the file to the remote server.
• Username field — The username the system should use to log in to the remote server. This field does not apply if the protocol is
TFTP or HTTP.
• Password field — The password for the remote server username.
This field does not apply if the protocol is TFTP or HTTP.
Selecting this option allows you to navigate to the private key stored on a drive that is local to the computer running the Cisco IMC GUI.
When you select this option, Cisco IMC GUI displays a Browse button that lets you navigate to the file you want to import.
Selecting this option allows you to copy the entire content of the signed private key and paste it in the Paste Private Key Content text field.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
301
Managing Certificates and Server Security
Exporting a Client Private Key
What to do next
Exporting a Client Private Key
Procedure
Step 1
Step 2
Step 3
Step 4
Step 5
In the Navigation pane, click the Admin menu.
In the Admin menu, click Security Management .
In the Security Management pane, click Secure Key Management .
In the Actions area of the Secure Key Management tab, click Export Client Private Key .
In the Export Client Private Key dialog box, complete these fields:
302
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Managing Certificates and Server Security
Name
Export to Remote Location
Exporting a Client Private Key
Description
Selecting this option allows you to choose the certificate from a remote location and export it. Enter the following details:
• • TFTP Server
• FTP Server
• SFTP Server
• SCP Server
• HTTP Server
Note If you chose SCP or SFTP as the remote server type while performing this action, a pop-up window is displayed with the message Server
(RSA) key fingerprint is
<server_finger_print _ID> Do you wish to continue?
. Click Yes or No depending on the authenticity of the server fingerprint.
The fingerprint is based on the host's public key and helps you to identify or verify the host you are connecting to.
• Server IP/Hostname field — The IP address or hostname of the server on which the certificate file should be exported. Depending on the setting in the Download Certificate from drop-down list, the name of the field may vary.
• Path and Filename field — The path and filename Cisco IMC should use when downloading the certificate from the remote server.
• Username field — The username the system should use to log in to the remote server. This field does not apply if the protocol is TFTP or
HTTP.
• Password field — The password for the remote server username. This field does not apply if the protocol is TFTP or HTTP.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
303
Managing Certificates and Server Security
Deleting a Client Private Key
Name
Export to Local File
Description
Selecting this option allows you to choose the certificate stored on a drive that is local to the computer and export it.
Deleting a Client Private Key
Procedure
Step 1
Step 2
Step 3
Step 4
Step 5
In the Navigation pane, click the Admin menu.
In the Admin menu, click Security Management .
In the Security Management pane, click Secure Key Management .
In the Actions area of the Secure Key Management pane, click Delete Client Private Key .
At the prompt, click OK or Cancel to delete the client private key, or cancel the action.
Testing the KMIP Server Connection
Procedure
Step 1
Step 2
Step 3
Step 4
Step 5
In the Navigation pane, click the Admin menu.
In the Admin menu, click Security Management .
In the Security Management pane, click Secure Key Management .
In the KMIP Servers area of the Secure Key Management tab, select a row by checking the check box and click Test Connection .
If the connection is successful, a success message is displayed.
Restoring the KMIP Server to Default Settings
Procedure
Step 1
Step 2
Step 3
Step 4
In the Navigation pane, click the Admin menu.
In the Admin menu, click Security Management .
In the Security Management pane, click Secure Key Management .
In the KMIP Servers area of the Secure Key Management tab, select a row by checking the check box and click Delete .
304
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Managing Certificates and Server Security
Deleting KMIP Login Details
Step 5 At the prompt, click OK
This restores the KMIP server to its default settings.
Deleting KMIP Login Details
Procedure
Step 1
Step 2
Step 3
Step 4
Step 5
In the Navigation pane, click the Admin menu.
In the Admin menu, click Security Management .
In the Security Management pane, click Secure Key Management .
In the Actions area of the Secure Key Management pane, click Delete KMIP Login .
At the prompt, click OK to delete the KMIP login details, or Cancel to cancel the action.
FIPS 140-2 Compliance in Cisco IMC
The Federal Information Processing Standard (FIPS) Publication 140-2, (FIPS PUB 140-2), is a U.S. government computer security standard used to approve cryptographic modules. Prior to the 3.1(3) release, the Rack Cisco
IMC is not FIPS compliant as per NIST guideline. It does not follow FIPS 140-2 approved cryptographic algorithms and modules. With this release, all CIMC services will use the Cisco FIPS Object Module (FOM), which provides the FIPS 140-2 compliant cryptographic module.
The Cisco FIPS Object Module is a software library that provides cryptographic services to a vast array of
Cisco's networking and collaboration products. The module provides FIPS 140 validated cryptographic algorithms and KDF functionality for services such as IPSec (IKE), SRTP, SSH, TLS, and SNMP.
Enabling Security Configuration
Before you begin
You must log in with admin privileges to perform this task.
Procedure
Step 1
Step 2
Step 3
Step 4
In the Navigation pane, click the Admin menu.
In the Admin menu, click Security Management .
In the Security Management pane, click Security Configuration .
In the Federal Information Processing Standard Configuration (FIPS) and Common Criteria (CC)
Configuration pane, check the Enable FIPS check-box.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
305
Managing Certificates and Server Security
Enabling Security Configuration
Table 3: Federal Information Processing Standard Configuration (FIPS) and Common Criteria (CC) Configuration
Name
Enable FIPS check box
Description
If checked, allows you to enable the FIPS feature. By default, this option is disabled.
When you enable FIPS, the following is an impact on the SNMP configuration:
• The community string configuration for the
SNMPv2 protocols, and the SNMPv3 users configured with noAuthNoPriv or authNoPriv security-level option are disabled.
• The traps configured for SNMPv2 or SNMPv3 users with the noAuthNoPriv security-level option are disabled.
• The MD5 and DES Authentication type and
Privacy type are disabled.
Note DES privacy type is not applicable for release 4.1(3b) or later. However, if DES was configured in an earlier release before you upgraded to release
4.1(3b) or later, then you may see
DES privacy type, which is disabled if FIPS is enabled.
• It also ensures only FIPS-compliant ciphers in
SSH, webserver, and vKVM connections.
• Allows the Common Criteria (CC) to be enabled.
• Disables TACACS+ Authentication.
Enable CC check box
Note
If checked, allows you to enable the CC feature. By default, this option is disabled.
When you switch the FIPS or CC mode, it restarts the SSH, KVM, SNMP, webserver, XMLAPI, and redfish services. You will be prompted to continue. If you wish to continue, click OK else click on Cancel .
306
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
C H A P T E R
15
Managing Firmware
This chapter includes the following sections:
•
Firmware Management Overview, on page 307
•
Viewing Firmware Components, on page 308
•
Updating the Firmware, on page 309
•
Activating the Firmware, on page 310
•
Cancelling Firmware Activation, on page 310
Firmware Management Overview
You can manage the following firmware components from a single page in the web UI:
• Adapter firmware —The main operating firmware, consisting of an active and a backup image, can be installed from different interfaces such as:
• Host Upgrade Utility (HUU)
• Web UI — Local and remote protocols
• PMCLI —Remote protocols
• XML API — Remote protocols
You can upload a firmware image from either a local file system or a TFTP server.
• Bootloader firmware—The bootloader firmware cannot be installed from the Cisco IMC. You can install this firmware using the Host Upgrade Utility.
Firmware for the following individual components can be updated:
• BMC
• BIOS
• CMC
• SAS Expander
• Adapter
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
307
Managing Firmware
Viewing Firmware Components
Firmware for the Hard Disk Drive (HDD) can also be installed from the same interfaces as the adapter firmware mentioned above.
Viewing Firmware Components
Procedure
Step 1
Step 2
In the Admin menu, click Firmware Management .
In the General tab's Firmware Management area, review the following information:
Name
Update button
Description
Opens a dialog box that allows you to install a firmware image file that is available to your local machine or on a remote server.
Activate button Opens a dialog box that allows you to select which available firmware version you would like to activate on the server.
Important If any firmware or BIOS updates are in progress, do not activate new firmware until those tasks complete.
Cancel Activation button
Component column
Running Version
Backup Version column column
Note This button is displayed only when you choose a BIOS firmware that is in
Activation Pending state.
This button allows you to cancel the selected BIOS activation that is in a pending state.
List of components available for which you can update the firmware.
The firmware version of the component that is currently active.
The alternate firmware version installed on the server, if any. The backup version is not currently running.
To activate it, click Activate .
Note When you install new firmware, any existing backup version is deleted and the new firmware becomes the backup version.
You must manually activate the new firmware if you want the server to run the new version.
308
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Managing Firmware
Name
Bootloader Version column
Status column
Progress in % column
Updating the Firmware
Description
The bootloader version associated with the boot-loader software of the component.
The status of the firmware activation on this server.
The progress of the operation, in percentage.
Updating the Firmware
You can install the firmware package from a local disk or from a remote server, depending on the component you choose from the Firmware Management area. After you confirm the installation, BMC replaces the firmware version in the component's backup memory slot with the selected version.
Procedure
Step 1
Step 2
Step 3
Step 4
Step 5
Step 6
In the Admin menu, click Firmware Management .
In the Firmware Management area, select a component from the Component column and click Update .
The Update Firmware dialog box appears.
Review the following information in the dialog box:
Name
Install Firmware through Browser Client radio button
Description
If the firmware package resides on a local machine, click this radio button.
Install Firmware through Remote Server radio button
If the firmware package resides on a remote server, click this radio button.
To install the firmware through the browser client, click Browse and navigate to the firmware file that you want to install.
After you select the file, click Install Firmware .
To update the firmware using remote server, select the remote server type from the Install Firmware from drop-down list. This could be one of the following:
• TFTP
• FTP
• SFTP
• SCP
• HTTP
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
309
Managing Firmware
Activating the Firmware
Step 7
Step 8
Depending on the remote server type you choose, enter details in the server's IP/Hostname and Image Path and Filename fields.
Once you install the firmware, the new image replaces the non-active image. You can activate the image after it is installed.
Important For FTP, SFTP, and SCP server types, you need to provide user credentials.
Click Install Firmware to begin download and installation.
Activating the Firmware
Procedure
Step 1
Step 2
Step 3
Step 4
In the Admin menu, click Firmware Management .
In the Firmware Management area, select a component from the Component column and click Activate .
The Activate Firmware dialog box appears.
In the Activate Firmware dialog box, select the desired firmware image (radio button) to activate. This image becomes the running version.
Click Activate Firmware .
Depending on the firmware image you chose, the activation process begins.
Important While the activation is in progress, do not:
• Reset, power off, or shut down the server
• Reboot or reset BMC
• Activate any other firmware
• Export technical support or configuration data
Cancelling Firmware Activation
Before you begin
BIOS firmware must be in Activation Pending state for you to cancel the activation.
Procedure
Step 1 In the Admin menu, click Firmware Management .
310
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Managing Firmware
Cancelling Firmware Activation
Step 2
Step 3
In the Firmware Management area, select the BIOS firmware for which you want to cancel the activation.
Click Cancel Activation .
Cancel Activation button is displayed only when you choose a BIOS firmware that is in Activation Pending
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
311
Cancelling Firmware Activation
Managing Firmware
312
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Viewing Faults and Logs
C H A P T E R
16
This chapter includes the following sections:
•
•
•
•
•
Faults Summary
Viewing the Fault Summary
Procedure
Step 1
Step 2
Step 3
In the Navigation pane, click the Chassis menu.
In the Chassis menu, click Faults and Logs .
In the Faults Summary tab, review the following information:
Table 4: Actions Area
Name
Total
Column drop-down list
Description
Displays the total number of rows in the Fault Entries table.
Allows you to choose the columns you wish to be displayed.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
313
Viewing Faults and Logs
Viewing the Fault Summary
Name
Show drop-down list
Table 5: Fault Entries Area
Name
Time
Severity
Description
Customize the way you want to view fault entries using filters. These can be:
• Quick Filter - Default view.
• Advanced Filter - Filter options to display the fault entries based on one or more criteria. Using the matching rule, you can view entries matching all the rules or any one combination of rules you specified in the Filter fields.
Click Go to view the entries matching the filter criteria that you set.
Click the Save icon to save the filter criteria that you set. This becomes a user-defined filter which you can use later.
Note The user-defined filter appears in the
Manage Preset Filters dialog box.
• All - Displays all entries
• Manage Preset Filters - Displays user-defined filters. You can edit or remove the user-defined filter from this dialog box.
• List of pre-defined filters - Displays the system-defined filters.
Note You can use the Filter icon to hide or unhide the filter fields.
Description
The time when the fault occurred.
This can be one of the following:
• Cleared - A fault or condition was cleared.
• Critical
• Info
• Major
• Minor
• Warning
The unique identifier assigned to the fault.
Code
314
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Viewing Faults and Logs
Name
DN
Probable Cause
Description
Fault History
Description
The distinguished name (DN) is a hierarchical representation of the device endpoint and its instance on the server.
The unique identifier associated with the event that caused the fault.
More information about the fault.
It also includes a proposed solution.
Fault History
Viewing Faults History
Procedure
Step 1
Step 2
Step 3
In the Navigation pane, click the Chassis menu.
In the Chassis menu, click Faults and Logs .
In the Faults History tab, review the following information
Table 6: Actions Area
Name
Total
Column drop-down list
Description
Displays the total number of rows in the Fault History table.
Allows you to choose the columns you wish to be displayed.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
315
Viewing Faults History
Name
Show drop-down list
Table 7: Faults History Area
Name
Time
Viewing Faults and Logs
Description
Customize the way you want to view fault history entries using filters. These can be:
• Quick Filter - Default view.
• Advanced Filter - Filter options to display the entries based on one or more criteria. Using the matching rule, you can view entries matching all the rules or any one combination of rules you specified in the Filter fields.
Click Go to view the entries matching the filter criteria that you set.
Click the Save icon to save the filter criteria that you set. This becomes a user-defined filter which you can use later.
Note The user-defined filter appears in the
Manage Preset Filters dialog box.
• All - Displays all entries
• Manage Preset Filters - Displays user-defined filters. You can edit or remove the user-defined filter from this dialog box.
• List of pre-defined filters - Displays the system-defined filters.
Note You can use the Filter icon to hide or unhide the filter fields.
Description
The time when the fault occurred.
316
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Viewing Faults and Logs
Cisco IMC Log
Name
Severity
Source
Probable Cause
Description
Description
This can be one of the following:
• Emergency
• Alert
• Critical
• Error
• Warning
• Notice
• Informational
• Debug
The software module that logged the event.
The unique identifier associated with the event that caused the fault.
More information about the fault.
It also includes a proposed solution.
What to do next
Cisco IMC Log
Viewing the Cisco IMC Log
Procedure
Step 1
Step 2
Step 3
In the Navigation pane, click the Chassis menu.
In the Chassis menu, click Faults and Logs .
In the Cisco IMC Log tab, review the following information:
Table 8: Actions Area
Name
Clear Log button
Description
Clears all log files.
Note This option is only available if your user
ID is assigned the admin or user user role.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
317
Viewing Faults and Logs
Viewing the Cisco IMC Log
Name
Total
Column drop-down list
Show drop-down list
Table 9: Cisco IMC Log Table
Name
Time column
Description
Displays the total number of rows in the Cisco IMC
Log table.
Allows you to choose the columns you wish to be displayed.
Customize the way you want to view Cisco IMC log entries using filters. These can be:
• Quick Filter - Default view.
• Advanced Filter - Filter options to display the log entries based on one or more criteria. Using the matching rule, you can view entries matching all the rules or any one combination of rules you specified in the Filter fields.
Click Go to view the entries matching the filter criteria that you set.
Click the Save icon to save the filter criteria that you set. This becomes a user-defined filter which you can use later.
Note The user-defined filter appears in the
Manage Preset Filters dialog box.
• All - Displays all entries
• Manage Preset Filters - Displays user-defined filters. You can edit or remove the user-defined filter from this dialog box.
• List of pre-defined filters - Displays the system-defined filters.
Note You can use the Filter icon to hide or unhide the filter fields.
Description
The date and time the event occurred.
318
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Viewing Faults and Logs
Name
Severity column
Description
The event severity. This can be one of the following:
• Emergency
• Alert
• Critical
• Error
• Warning
• Notice
• Informational
• Debug
The software module that logged the event.
A description of the event.
System Event Log
Source column
Description column
System Event Log
Viewing System Event Logs
The System Event Log tab displays only the recent 3008 system events, as against the total capacity of 131068 entries in the Cisco System Event Log (Cisco SEL) stored internally. When the Cisco SEL reaches its full capacity (131068 records), the oldest entries are overwritten with the most recent entries.
Procedure
Step 1
Step 2
Step 3
In the Navigation pane, click the Chassis menu.
In the Chassis menu, click Faults and Logs .
On the System Event Log tab, review the following information:
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
319
Viewing System Event Logs
Table 10: Actions Area
Name
SEL Fullness Indicator
Clear Log button
Chassis drop-down list
Total
Column drop-down list
Viewing Faults and Logs
Description
Displays, in percentage, the used space in the System
Event Log tab. The percentage is calculated with 3008 entries as the reference (the System Event Log tab always displays only the most recent 3008 system events). For example, if there are 1504 entries in the
System Event Log tab, then the percentage is shown as 50.
After the first set of 3008 entries are reached, the status is always displayed as 100% until the SEL is cleared.
Clears all events from the log file.
Note This option is only available if your user
ID is assigned the admin or user user role.
Select a chassis or a server to view its logs.
Displays the total number of rows in the System Event
Log table.
Allows you to choose the columns you wish to be displayed.
320
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Viewing Faults and Logs
Viewing System Event Logs
Name
Show drop-down list
Description
Customize the way you want to view events using filters. These can be:
• Quick Filter - Default view.
• Advanced Filter - Filter options to display the events based on one or more criteria. Using the matching rule, you can view entries matching all the rules or any one combination of rules you specified in the Filter fields.
Click Go to view the entries matching the filter criteria that you set.
Click the Save icon to save the filter criteria that you set. This becomes a user-defined filter which you can use later.
Note The user-defined filter appears in the
Manage Preset Filters dialog box.
• All - Displays all entries
• Manage Preset Filters - Displays user-defined filters. You can edit or remove the user-defined filter from this dialog box.
• List of pre-defined filters - Displays the system-defined filters.
Note You can use the Filter icon to hide or unhide the filter fields.
Table 11: System Event Log Table
Name
Time column
Severity column
Description column
Description
The date and time the event occurred.
The severity field includes both text and a color-coded icon. For the icon, green indicates normal operation, yellow is informational, and warning, critical, and non-recoverable errors are shown in shades of red.
A description of the event.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
321
Viewing Faults and Logs
Logging Controls
Logging Controls
Viewing Logging Controls
Procedure
Step 1
Step 2
Step 3
In the Navigation pane, click the Chassis menu.
In the Chassis menu, click Faults and Logs .
In the Logging Controls tab, review the following information:
Remote Logging
Name
Enabled check box
Description
If checked, the Cisco IMC sends log messages to the Syslog server named in the IP Address field.
Host Name/IP Address field
Port field
The address of the Syslog server on which the Cisco IMC log should be stored. You can set an IPv4 or IPv6 address or a domain name as the remote system address.
Enter a destination port number of the Syslog server within the range 1 to 65535. The default port number is 514.
Protocol field The transport layer protocol for transmission of syslog messages. You can select one of the following:
• TCP
• UDP
Minimum Severity to Report field Specify the lowest level of messages that will be included in the remote logs. You can select one of the following:
• Emergency
• Alert
• Critical
• Error
• Warning
• Notice
• Informational
• Debug
322
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Viewing Faults and Logs
Sending the Cisco IMC Log to a Remote Server
Note The Cisco IMC does not remotely log any messages with a severity below the selected severity.
For example, if you select Error , then the Cisco IMC remote log contains all messages with the severity Emergency , Alert , Critical , or Error . It does not show Warning , Notice , Informational , or Debug messages.
Local Logging
This area displays only the Minimum Severity to Report drop-down list as shown in the table above. You can specify the lowest level of messages to be included in the local log
Sending the Cisco IMC Log to a Remote Server
You can configure profiles for one or two remote syslog servers to receive Cisco IMC log entries.
Before you begin
• The remote syslog server must be configured to receive logs from a remote host.
• The remote syslog server must be configured to receive all types of logs, including authentication-related logs.
• The remote syslog server's firewall must be configured to allow syslog messages to reach the syslog server.
Procedure
Step 1
Step 2
Step 3
Step 4
In the Navigation pane, click the Chassis menu.
In the Chassis menu, click Faults and Logs .
In either of the Remote Syslog Server areas, complete the following fields:
Name
Enabled check box
Description
If checked, the Cisco IMC sends log messages to the Syslog server named in the IP Address field.
Host Name/IP Address field
Port field
The address of the Syslog server on which the Cisco IMC log should be stored. You can set an IPv4 or IPv6 address or a domain name as the remote system address.
Enter a destination port number of the Syslog server within the range 1 to 65535. The default port number is 514.
(Optional) In the Minimum Severity to Report drop-down list, specify the lowest level of messages that will be included in the remote logs.
You can select one of the following, in decreasing order of severity:
• Emergency
• Alert
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
323
Viewing Faults and Logs
Configuring the Cisco IMC Log Threshold
Step 5
Note
• Critical
• Error
• Warning
• Notice
• Informational
• Debug
Cisco IMC does not remotely log any messages with a severity below the selected severity. For example, if you select Error , then the Cisco IMC remote log will contain all messages with the severity Emergency, Alert, Critical, or Error. It will not show Warning, Notice, Informational, or
Debug messages.
Click Save Changes .
Configuring the Cisco IMC Log Threshold
Before you begin
Procedure
Step 1
Step 2
Step 3
In the Navigation pane, click the Chassis menu.
In the Chassis menu, click Faults and Logs .
Required: In the Local Logging area, use the Minimum Severity to Report drop-down list to specify the lowest level of messages that will be included in the Cisco IMC log.
You can select one of the following, in decreasing order of severity:
• Emergency
• Alert
• Critical
• Error
• Warning
• Notice
• Informational
• Debug
324
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Viewing Faults and Logs
Sending a Test Cisco IMC Log to a Remote Server
Note Cisco IMC does not log any messages with a severity below the selected severity. For example, if you select Error , then the Cisco IMC log will contain all messages with the severity Emergency,
Alert, Critical, or Error. It will not show Warning, Notice, Informational, or Debug messages.
Sending a Test Cisco IMC Log to a Remote Server
Before you begin
• The remote syslog server must be configured to receive logs from a remote host.
• The remote syslog server must be configured to receive all types of logs, including authentication-related logs.
• The remote syslog server's firewall must be configured to allow syslog messages to reach the syslog server.
Procedure
Step 1
Step 2
Step 3
Step 4
In the Navigation pane, click the Chassis menu.
In the Chassis menu, click Faults and Logs .
In the Faults and Logs pane, click the Logging Controls tab.
In the Action area, click Send Test Syslog .
A test Cisco IMC log is sent to the configured remote servers.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
325
Sending a Test Cisco IMC Log to a Remote Server
Viewing Faults and Logs
326
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
C H A P T E R
17
Server Utilities
This chapter includes the following sections:
•
Exporting Technical Support Data, on page 327
•
Resetting to Factory Default, on page 330
•
Exporting and Importing the Cisco IMC Configuration, on page 331
•
Generating Non Maskable Interrupts to the Host, on page 337
•
Adding or Updating the Cisco IMC Banner, on page 337
•
Viewing Cisco IMC Last Reset Reason, on page 338
•
Downloading Hardware Inventory to a Local File, on page 339
•
Exporting Hardware Inventory Data to a Remote Server, on page 339
•
Uploading a PID Catalog, on page 340
•
Activating a PID Catalog, on page 342
•
Deleting a PID Catalog, on page 342
•
Enabling Smart Access USB, on page 343
•
Enabling or Disabling Cisco Intersight Management, on page 344
•
Viewing Intersight Device Connector Properties, on page 344
•
Recovering PCIe Switch, on page 347
Exporting Technical Support Data
Exporting Technical Support Data
Perform this task when requested by the Cisco Technical Assistance Center (TAC). This utility creates a summary report containing configuration information, logs and diagnostic data that will help TAC in troubleshooting and resolving a technical issue.
Procedure
Step 1
Step 2
Step 3
Step 4
In the Navigation pane, click the Admin menu.
In the Admin menu, click Utilities .
In the Actions area of the Utilities pane, click Export Technical Support Data .
In the Export Technical Support Data dialog box, complete the following fields:
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
327
Server Utilities
Exporting Technical Support Data
Name
Export Technical Support Data through drop-down list
Description
Note Front Panel USB option is visible only if Smart Access
USB is enabled and a USB storage device is connected to the server.
You can export the technical support data to a remote server or to a USB storage device connected to a server. You can choose one of the following:
• Remote — This allows you to export the technical support data to a remote server using one of the following protocols:
• TFTP
• FTP
• SFTP
• SCP
• HTTP
Note If you chose SCP or SFTP as the remote server type while performing this action, a pop-up window is displayed with the message Server (RSA) key fingerprint is <server_finger_print _ID> Do you wish to continue?
. Click Yes or No depending on the authenticity of the server fingerprint.
The fingerprint is based on the host's public key and helps you to identify or verify the host you are connecting to.
Server IP/Hostname
Path and Filename
Username
Password field field
• Front Panel USB —This allows you to export the technical support data to a USB storage device connected to the server.
The IP address or hostname of the server on which the support data file should be stored. Depending on the setting in the Export Technical
Support Data to drop-down list, the name of the field may vary.
The path and filename Cisco IMC should use when exporting the file to the remote server.
Note If the server includes any of the supported network adapter cards, the data file also includes technical support data from the adapter card.
The username the system should use to log in to the remote server. This field does not apply if the protocol is TFTP or HTTP.
The password for the remote server username. This field does not apply if the protocol is TFTP or HTTP.
328
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Server Utilities
Downloading Technical Support Data to a Local File
Step 5 Click Export .
What to do next
Provide the generated report file to Cisco TAC.
Downloading Technical Support Data to a Local File
Perform this task when requested by the Cisco Technical Assistance Center (TAC). This utility creates a summary report containing configuration information, logs and diagnostic data that will help TAC in troubleshooting and resolving a technical issue.
Procedure
Step 1
Step 2
Step 3
Step 4
In the Navigation pane, click the Admin menu.
In the Admin menu, click Utilities .
In the Actions area of the Utilities pane, click Generate Technical Support Data for Local Download .
In the Download Technical Support Data to Local File dialog box, complete the following fields:
Name Description
Generate Technical Support Data radio button
Cisco IMC disables this radio button when there is no technical support data file to download.
Click Generate to create the data file. When data collection is complete, click Download Technical Support Data to Local File in the Actions area to download the file.
Regenerate Technical Support
Data radio button
Cisco IMC displays this radio button when a technical support data file is available to download.
To replace the existing support data file with a new one, select this option and click Regenerate . When data collection is complete, click Download
Technical Support Data to Local File in the Actions area to download the file.
Download to local file radio button Cisco IMC enables this radio button when a technical support data file is available to download.
To download the existing file, select this option and click Download .
Note If the server includes any of the supported network adapter cards, the data file also includes technical support data from the adapter card.
Generate button
Download button
Allows you to generate the technical support data file.
Allows you to download the technical support data file after it is generated.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
329
Server Utilities
Resetting to Factory Default
Step 5 Click Generate to create the data file. When data collection is complete, click Download Technical Support
Data to Local File in the Actions area to download the file..
What to do next
Provide the generated report file to Cisco TAC.
Resetting to Factory Default
On rare occasions, such as an issue with the current running firmware or troubleshooting a server, you might require to reset the server components to the factory default. When this happens, all user-configurable settings are reset.
This procedure is not part of the normal server maintenance. After you reset the server components, you are logged off and must log in again. You might also lose connectivity and might need to reconfigure the network settings. Some of the inventory information might not be available during this transition.
When you reset the BMC to factory settings, the serial number is displayed in the Cisco IMCXXXXXX format, where XXXXXX is the serial number of the server.
Important When you move VIC adapters from other generation C-Series servers (for example M4 servers) to the
M5 generation C-Series servers or M5 servers to other generation servers, you must reset the adapters to factory defaults.
Before you begin
You must log in as a user with admin privileges to reset the server components to factory defaults.
Procedure
Step 1
Step 2
Step 3
Step 4
In the Navigation pane, click the Admin menu.
In the Admin menu, click Utilities .
In the Actions area of the Utilities pane, click Reset to Factory Default .
In the Reset to Factory Default dialog box, review the following information:
Name
All checkbox
Description
If checked, it resets all the components of the server to factory settings.
Expand to select the specific component that you want to reset to factory settings.
330
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Server Utilities
Exporting and Importing the Cisco IMC Configuration
Step 5
Name
BMC checkbox
Storage
VIC checkbox checkbox
Description
If checked, it resets the BMC to factory settings.
Note After you reset the BMC to factory settings, the serial number is displayed in the Cisco IMCXXXXXX format, where
XXXXXX is the serial number of the server. After factory defaults of BMC NIC Mode, Shared LOM Extended is configured by default.
If checked, it resets all the available storage adapters to factory settings.
When you reset a storage adapter, the data on the disk is not modified but the virtual drive meta data will be erased which may result in data loss. Expand to select the specific storage adapters that you want to reset to factory settings.
Note The host must be powered on to reset storage adapters to factory defaults.
If checked, it resets all the available VICs to factory settings.
Expand to select the specific VICs that you want to reset to factory settings.
Note The host must be powered on to reset VIC adapters to factory defaults.
Reset button Resets the selected components to the factory settings.
Click Reset to reset the selected components to the factory-default settings.
A reboot of Cisco IMC, while the host is performing BIOS POST (Power on Self Test) or is in EFI shell, powers down the host for a short amount of time. Cisco IMC powers on when it is ready. Upon restart, the network configuration mode is set to Cisco Card mode by default.
Exporting and Importing the Cisco IMC Configuration
Exporting and Importing the Cisco IMC Configuration
To perform a backup of the Cisco IMC configuration, you take a snapshot of the system configuration and export the resulting Cisco IMC configuration file to a location on your network. The export operation saves information from the management plane only; it does not back up data on the servers. Sensitive configuration information such as user accounts and the server certificate are not exported.
You can restore an exported Cisco IMC configuration file to the same system or you can import it to another
Cisco IMC system, provided that the software version of the importing system is the same as or is configuration-compatible with the software version of the exporting system. When you import a configuration file to another system as a configuration template, you must modify system-specific settings such as IP addresses and host names. An import operation modifies information on the management plane only.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
331
Server Utilities
Exporting the Cisco IMC Configuration
The Cisco IMC configuration file is an XML text file whose structure and elements correspond to the Cisco
IMC command modes.
When performing an export or import operation, consider these guidelines:
• You can perform an export or an import while the system is up and running. While an export operation has no impact on the server or network traffic, some modifications caused by an import operation, such as IP address changes, can disrupt traffic or cause a server reboot.
• You cannot execute an export and an import simultaneously.
You can perform an import or an export operation on the following features:
• Cisco IMC version
Note You can only export this information.
• Network settings
• Technical support
• Logging control for local and remote logs
• Power policies
• BIOS - BIOS Parameters
Note Precision boot is not supported.
• Communication services
• Remote presence
• User management - LDAP
• Event management
• SNMP
Exporting the Cisco IMC Configuration
Note For security reasons, this operation does not export user accounts or the server certificate.
Before you begin
Obtain the backup remote server IP address.
332
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Server Utilities
Exporting the Cisco IMC Configuration
Procedure
Step 1
Step 2
Step 3
Step 4
In the Navigation pane, click the Admin menu.
In the Admin menu, click Utilities .
In the Actions area of the Utilities pane, click Export Configuration .
In the Export Configuration dialog box, complete the following fields:
Name
Select Component for Export drop-down list
Description
The component type. This can be one of the following:
• BMC
• VIC Adapter(s)
Export To drop-down list
Depending on the component you choose, the configuration of that component is exported.
The location where you want to save the XML configuration file. This can be one of the following:
• Local : Select this option and click Export to save the XML configuration file to a drive that is local to the computer running the Cisco IMC GUI..
When you select this option, Cisco IMC GUI displays a File
Download dialog box that lets you navigate to the location to which the configuration file should be saved.
• Remote Server : Select this option to import the XML configuration file from a remote server.
When you select this option, Cisco IMC GUI displays the remote server fields.
• Front Panel USB : Select this option to export the configuration file to a USB storage device connected to the server.
Note • Front Panel USB option to export Cisco IMC configuration is available only if Smart Access USB is enabled and a USB storage device is connected to the server.
• This option is available only when you choose BMC in the Select Component drop-down list.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
333
Server Utilities
Importing the Cisco IMC Configuration
Name
Export To drop-down list
Server IP/Hostname field
Path and Filename
Username
Password
Passphrase field
Description
The remote server type. This can be one of the following:
• TFTP Server
• FTP Server
• SFTP Server
• SCP Server
• HTTP Server
Note If you chose SCP or SFTP as the remote server type while performing this action, a pop-up window is displayed with the message Server (RSA) key fingerprint is
<server_finger_print _ID> Do you wish to continue?
. Click
Yes or No depending on the authenticity of the server fingerprint.
The fingerprint is based on the host's public key and helps you to identify or verify the host you are connecting to.
The IPv4 or IPv6 address, or hostname of the server to which the configuration file will be exported. Depending on the remote server type selected in the Export to drop-down list, the name of the field may vary.
The path and filename Cisco IMC should use when exporting the file to the remote server.
The username the system should use to log in to the remote server. This field does not apply if the protocol is TFTP or HTTP.
The password for the remote server username. This field does not apply if the protocol is TFTP or HTTP.
The passphrase that uses the AES256 algorithm to encrypt the LDAP and SNMP v3 user passwords in the exported configuration files. Enter a string of 6 to 127 characters. Do not enter the following characters: !
# $ & < > ? ; ' | ` ~ \ % ^ ( )"
Step 5 Click Export .
Importing the Cisco IMC Configuration
Before you begin
If you want to restore the SNMP configuration information when you import the configuration file, make sure that SNMP is disabled on this server before you do the import. If SNMP is enabled when you perform the import, Cisco IMC does not overwrite the current values with those saved in the configuration file.
334
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Server Utilities
Importing the Cisco IMC Configuration
Procedure
Step 1
Step 2
Step 3
Step 4
In the Navigation pane, click the Admin menu.
In the Admin menu, click Utilities .
In the Actions area of the Utilities pane, click Import Configuration .
In the Import Configuration dialog box, complete the following fields:
Name
Select Component for Import drop-down list
Description
The component type. This can be one of the following:
• BMC
• VIC Adapter(s)
Import From drop-down list
Depending on the component you choose, the configuration of that component is imported.
The location of the XML configuration file. This can be one of the following:
• Local : Select this option to import the XML configuration file to a drive that is local to the computer running Cisco IMC GUI.
When you select this option, Cisco IMC GUI displays a Browse button that lets you navigate to the file you want to import.
• Remote Server : Select this option to import the XML configuration file from a remote server.
When you select this option, Cisco IMC GUI displays the remote server fields.
• Front Panel USB : Select this option to import the configuration file from a USB storage device connected to the server.
Note • Front Panel USB option to import Cisco IMC configuration is available only if Smart Access USB is enabled and a USB storage device is connected to the server.
• This option is available only when you choose BMC in the Select Component drop-down list.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
335
Server Utilities
Importing the Cisco IMC Configuration
Name
Import From drop-down list
Server IP/Hostname
Path and Filename
Username
Password
Passphrase field field
Description
Note These options are available only when you choose Remote .
The remote server type. This can be one of the following:
• TFTP Server
• FTP Server
• SFTP Server
• SCP Server
• HTTP Server
Note If you chose SCP or SFTP as the remote server type while performing this action, a pop-up window is displayed with the message Server (RSA) key fingerprint is
<server_finger_print _ID> Do you wish to continue?
. Click
Yes or No depending on the authenticity of the server fingerprint.
The fingerprint is based on the host's public key and helps you to identify or verify the host you are connecting to.
The IPv4 or IPv6 address, or hostname of the server on which the configuration file resides. Depending on the remote server type selected in the Import From drop-down list, the name of the field might vary.
The path and filename of the configuration file on the remote server.
The username the system should use to log in to the remote server. This field does not apply if the protocol is TFTP or HTTP.
The password for the remote server username. This field does not apply if the protocol is TFTP or HTTP.
The passphrase that uses the AES256 algorithm to encrypt the LDAP and SNMP v3 user passwords in the imported configuration files. Enter a string of 6 to 127 characters. Do not enter the following characters: !
# $ & < > ? ; ' | ` ~ \ % ^ ( )"
Note If you edit the encrypted sections in the configuration file and try to import it, the edits will be ignored and the import operation displays a partially successful message.
Step 5 Click Import .
336
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Server Utilities
Generating Non Maskable Interrupts to the Host
Generating Non Maskable Interrupts to the Host
In some situations, the server might hang and not respond to traditional debug mechanisms. By generating a non maskable interrupt (NMI) to the host, you can create and send a crash dump file of the server and use it to debug the server.
Depending on the type of operating system associated with the server, this task might restart the OS.
Before you begin
• You must log in as a user with admin privileges.
• The server must be powered on.
Procedure
Step 1
Step 2
Step 3
Step 4
In the Navigation pane, click the Admin menu.
In the Admin menu, click Utilities .
In the Actions area of the Utilities pane, click Generate NMI to Host .
In the Generate NMI to Host dialog box, review the following information:
Actions Description
Generate NMI to drop-down list Allows you to select the server for which you want to generate the non maskable interrupt (NMI). This can be one of the following:
• Server 1
• Server 2
Step 5 Click Send .
This action sends an NMI signal to the host, which might restart the OS.
Adding or Updating the Cisco IMC Banner
You can add or update the Cisco IMC banner by entering important information such as copyright or customized messages. Complete the following steps:
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
337
Server Utilities
Viewing Cisco IMC Last Reset Reason
Before you begin
Procedure
Step 1
Step 2
Step 3
Step 4
Step 5
In the Navigation pane, click the Admin menu.
In the Admin menu, click Utilities .
In the Actions area of the Utilities pane, click Add/Update Cisco IMC Banner .
In the Add/Update Cisco IMC Banner dialog box, complete the following fields:
Name Description
Banner (80 Chars per line. Max
2K Chars.) field
Enter copyright information or messages that you want to display on the login screen, before logging on to the Web UI or the command line interface.
Restart SSH checkbox When checked, the active SSH sessions are terminated after you click the Save Banner button.
Click Save Banner .
What to do next
Viewing Cisco IMC Last Reset Reason
Procedure
Step 1
Step 2
Step 3
In the Navigation pane, click the Admin menu.
In the Admin menu, click Utilities .
In the Actions area of the Utilities pane, view the following information under the Last Reset Reason area.
Name
Component field
Description
The component that was last reset.
Status field The reason why the component was last reset. This can be one of the following:
• watchdog-reset —The watchdog-timer resets when the Cisco IMC memory reaches full capacity.
• ac-cycle — PSU power cables are removed (no power input).
• graceful-reboot — Cisco IMC reboot occurs.
338
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Server Utilities
Downloading Hardware Inventory to a Local File
Downloading Hardware Inventory to a Local File
Procedure
Step 1
Step 2
Step 3
Step 4
Step 5
In the Navigation pane, click the Admin menu.
In the Admin menu, click Utilities .
In the Actions area of the Utilities pane, click Generate Inventory Data .
In the Generate Inventory Data dialog box, complete the following fields:
Name
Generate Inventory Data radio button
Description
Cisco IMC displays this radio button when there is no hardware inventory data file to download.
Download to local file radio button Cisco IMC enables this radio button when a inventory data file is available to download.
To download the existing file, select this option and click Download .
Click Generate to create the data file. When data collection is complete, select the Download Inventory
Data to Local File radio button and click Download to download the file locally.
Exporting Hardware Inventory Data to a Remote Server
Procedure
Step 1
Step 2
Step 3
Step 4
In the Navigation pane, click the Admin menu.
In the Admin menu, click Utilities .
In the Actions area of the Utilities pane, click Export Hardware Inventory Data to Remote .
In the Export Hardware Inventory Data dialog box, complete the following fields:
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
339
Server Utilities
Uploading a PID Catalog
Step 5
Name Description
Export Hardware Inventory Data to drop-down list
The remote server type. This can be one of the following:
• TFTP Server
• FTP Server
• SFTP Server
• SCP Server
• HTTP Server
Note If you chose SCP or SFTP as the remote server type while performing this action, a pop-up window is displayed with the message Server (RSA) key fingerprint is
<server_finger_print _ID> Do you wish to continue?
. Click
Yes or No depending on the authenticity of the server fingerprint.
The fingerprint is based on the host's public key and helps you to identify or verify the host you are connecting to.
Server IP/Hostname field
Path and Filename
Username
Password field
The IP address or hostname of the server on which the data file should be stored. Depending on the setting in the Export Hardware Inventory
Data to drop-down list, the name of the field may vary.
The path and filename Cisco IMC should use when exporting the file to the remote server.
The username the system should use to log in to the remote server. This field does not apply if the protocol is TFTP or HTTP.
The password for the remote server username. This field does not apply if the protocol is TFTP or HTTP.
Click Export .
Uploading a PID Catalog
Before you begin
You must log in as a user with admin privileges to upload a PID catalog.
Procedure
Step 1
Step 2
In the Navigation pane, click the Admin tab.
On the Admin tab, click Utilities .
340
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Server Utilities
Uploading a PID Catalog
Step 3
Step 4
Step 5
In the Work pane, click the Upload PID Catalog link.
The Upload PID Catalog dialog box appears.
Depending on the location of the catalog file, choose one of the options.
In the Upload PID Catalog from Local File dialog box, click Browse and use the Choose File to Upload dialog box to select the catalog file that you want to upload.
Name
File field
Browse button
Description
The PID catalog file that you want to upload.
Opens a dialog box that allows you to navigate to the appropriate file.
In the Upload PID Catalog from Remote Server dialog box, complete the following fields:
Name Description
Upload PID Catalog from Remote Server drop-down list
The remote server type. This can be one of the following:
• TFTP
• FTP
• SFTP
• SCP
• HTTP
Server IP/Hostname field
Path and Filename
Username field
Password field
Upload button field
The IP address or hostname of the server on which the PID catalog information is available. Depending on the setting in the Upload PID Catalog from drop-down list, the name of the field may vary.
The path and filename of the catalog file on the remote server.
Username of the remote server.
Password of the remote server.
Uploads the selected PID catalog.
Note If you chose SCP or SFTP as the remote server type while performing this action, a pop-up window is displayed with the message Server (RSA) key fingerprint is
<server_finger_print _ID> Do you wish to continue?
. Click Yes or No depending on the authenticity of the server fingerprint.
The fingerprint is based on the host's public key and helps you to identify or verify the host you are connecting to.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
341
Server Utilities
Activating a PID Catalog
Name
Cancel button
Description
Closes the wizard without making any changes to the firmware versions stored on the server.
Activating a PID Catalog
Caution BMC reboots automatically once a PID catalog is activated.
You must reboot the server after activating a PID catalog.
Before you begin
You must log in as a user with admin privileges to activate a PID catalog.
Procedure
Step 1
Step 2
Step 3
In the Navigation pane, click the Admin tab.
On the Admin tab, click Utilities .
In the Work pane, click the Activate PID Catalog link.
The Activate PID Catalog dialog box appears. Complete the following fields:
Name
Activate button
Description
Allows you to activate the PID catalog.
Note The Activate PID Catalog link is greyed out when you log on to the system for the first time. It gets activated once you upload a PID catalog to the server. After you upload a PID file, the link remains active and you can activate the PID multiple times.
Deleting a PID Catalog
Caution BMC reboots automatically once a PID catalog is deleted.
You must reboot the server after deleting a PID catalog.
342
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Server Utilities
Enabling Smart Access USB
Before you begin
You must log in as a user with admin privileges to perform this task.
Procedure
Step 1
Step 2
Step 3
In the Navigation pane, click the Admin tab.
In the Admin tab, click Utilities .
In the Actions area of the Utilities pane, click Delete PID Catalog and click OK to confirm.
Note You can delete a PID catalog only if it has been previously updated and activated.
Enabling Smart Access USB
When you enable the smart access USB feature, the front panel USB device disconnects from the host operating system and connects to Cisco IMC. After enabling the smart access USB feature, you can use the front panel
USB device to export technical support data, import or export Cisco IMC configuration, or update Cisco IMC,
BIOS, and VIC firmware.
The supported file systems for smart access USB are as follows:
• EXT2
• EXT3
• EXT 4
• FAT 32
• FAT 16
• DOS
Note Huge file support is not supported in BMC. For EXT 4 file system, huge file support has to be turned off.
Before you begin
You must log in with admin privileges to perform this task.
Procedure
Step 1
Step 2
Step 3
In the Navigation pane, click the Admin tab.
In the Admin menu, click Utilities .
In the Actions area, click Enable Smart Access USB .
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
343
Server Utilities
Enabling or Disabling Cisco Intersight Management
This is a toggle button. To disable smart access, click Disable Smart Access USB . This button is visible only after you enable smart access USB. When you disable the smart access USB feature, the front panel USB device disconnects from Cisco IMC and connects to the host operating system.
Enabling or Disabling Cisco Intersight Management
When you enable the Intersight management, it establishes a bi-directional communication between the
Intersight Cloud application and the M5 server.
Note Port numbers 8888-8889 are reserved for Intersight communication.
Procedure
Step 1
Step 2
Step 3
Step 4
Step 5
In the Navigation pane, click the Admin tab.
In the Admin tab, click Device Connector .
In the Intersight Management area, click On to enable the Intersight management.
The Connection area displays the connection status of the Intersight management. If the device connector has not been able to establish a connection to Intersight management, review the recommendations provided in the Details & Recommendations drop-down list to fix the connection issues.
Select the Access Mode as Read-only or Allow Control.
When the Read-only access mode is selected, then you cannot configure the device through Intersight.
Therefore, any configuration that comes to the device connector through cloud is rejected with an error code.
If the Allow Control mode is selected, then you have full control to configure the device through Intersight.
To disable the Intersight management, click Off .
When you disable the Intersight management, the Connection area displays the connection status as
Administratively Disabled .
Viewing Intersight Device Connector Properties
Procedure
Step 1
Step 2
Step 3
In the Navigation pane, click the Admin tab.
In the Admin tab, click Device Connector .
In the Intersight Management area, review the following information:
344
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Server Utilities
Viewing Intersight Device Connector Properties
Action Name
Enabled radio button
Description
Allows you to enable or disable the Intersight management. This can be one of the following:
• On —Enables the Intersight management. You can claim this system and leverage the capabilities of Cisco Intersight.
• Off —Disables the Intersight management. No communication will be allowed to Cisco
Intersight.
Step 4 In the Connection area, review the following information:
Name Description
Status field Displays the status of the connection to Intersight.
This can be one of the following:
• Administratively Disabled —Indicates that the
Intersight management has been disabled.
• DNS Misconfigured — Indicates that the DNS details have not been configured in BMC.
• UCS Connect Network Error —Indicates the invalid network configurations.
• Certification Validation Error —Indicates invalid certificate.
• Claimed —Indicates that the device is claimed in Intersight.
• Not Claimed —Indicates that the device is registered, but not claimed in Intersight.
Access Mode
Details & Recommendations drop-down list
Device ID
Claim Code
The mode will be Allow Control by default.
Lists the details and recommendations to fix the connection issues based on the status.
This indicates the ID of the device.
This is the security code required to claim the device from Intersight.
Note This code is available only when
Connection status is Not Claimed .
Step 5 In the Settings area, review the following information:
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
345
Server Utilities
Viewing Intersight Device Connector Properties
Name
General tab
Description
Access Mode
• Read-only — When the Read-only access mode is selected, you cannot configure the device through Intersight.
• Allow Control — When the Allow Control mode is selected, you will have full control to configure the device through Intersight.
Proxy Configuration tab
HTTPS Proxy field radio button
Proxy Hostname/IP field
Configuration from Intersight only
This option is configurable only when Allow Control mode is enabled. The
Configure Lockout options are as follows:
OFF — To manage the device both locally and from Intersight you can turn OFF the option Configuration from Intersight only . The setting will terminate all the existing sessions (webUI, XML and CLI).
ON — To lock out Cisco IMC configuration for Intersight you can turn ON the option Configuration from Intersight only . The setting will terminate all the existing sessions (webUI, XML and CLI).
Note When you are logged in as admin in the Configuration Lock Out mode, the admin role will be mapped to the User role, so the interfaces behave as user logged in with the User role.
Allows you to manually configure HTTPS proxy settings required for the Intersight connection.
OFF - Disables the HTTPS proxy settings.
ON - Enables the HTTPS proxy settings.
The IP address or the host name of the proxy server.
Proxy Port field The port number of the proxy server.
Authentication toggle button
Enabling this option allows you to provide the credentials for the proxy server.
Note The Device Connector does not mandate the format of the login credentials. They are passed as-is to the configured HTTP proxy server.
Whether or not the username must be qualified with a domain name will depend on the configuration of the HTTP proxy server.
Username field
Password field
The credentials for the proxy server.
346
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Server Utilities
Recovering PCIe Switch
Name
Certificate Manager tab
Description
Allows you to view a list of trusted certificates and import a valid trusted certificate.
• Import —Allows you to select and Import a CA signed certificate.
Note The imported certificates must be in the *.pem (base64 encoded) format.
• You can view the list of certificates with the following information:
• Name —Common name of the CA certificate.
• In Use —Whether the certificate in the trust store was used to successfully verify the remote server.
• Issued By —The issuing authority for the certificate.
• Expires —The expiry date of the certificate.
Note You cannot delete bundled certificates (certificates with the lock icon).
Recovering PCIe Switch
Before you begin
• You must log in as a user with admin privileges.
• The server must be powered on.
Procedure
Step 1
Step 2
Step 3
Step 4
In the Navigation pane, click the Admin menu.
In the Admin menu, click Utilities .
In the Actions area of the Utilities pane, click Recover PCIe Switch .
In the Recover PCIe Switch dialog box, review the following information:
Name
Controller drop-down
Description
Lists the PCIe switches available on the server. You can select the switch on which you want to perform the recover controller action from this list.
Recover Controller button Clicking on the recover controller button initiates the recovery of the chosen controller.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
347
Recovering PCIe Switch
Name
Cancel button
Description
Cancels the action and closes the dialog box.
Server Utilities
348
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
C H A P T E R
18
Troubleshooting
This chapter includes the following sections:
•
Recording the Last Boot Process, on page 349
•
Recording the Last Crash, on page 350
•
Downloading a DVR Player, on page 351
•
Playing a Recorded Video Using the DVR Player on the KVM Console, on page 352
Recording the Last Boot Process
Procedure
Step 1
Step 2
Step 3
Step 4
Step 5
Step 6
Step 7
Step 8
In the Navigation pane, click the Compute menu.
In the work pane, click the TroubleShooting tab.
In the Bootstrap Process Recording area of the Troubleshooting tab, check Enable Recording check-box.
By default, this option is enabled.
Caution This task is for troubleshooting purpose, and might impact Cisco IMC performance if it is enabled all the time.
(Optional) If you want to record the boot process until BIOS POST, then check Stop On BIOS POST check-box.
Click Save Changes
On the tool bar above the Work pane, click Power On Server .
In the Actions area, of the Bootstrap Process Recording pane, click Play Recording .
A confirmation dialog box with instructions on supported Java version appears.
Review the instructions and click Ok .
The DVR Player Controls dialog box opens. This dialog box plays the recording of the last boot process. If you have enabled Stop On BIOS POST option then the system plays the recording process only till BIOS
POST.
This recording can be reviewed to analyze the factors that caused the system to reboot.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
349
Troubleshooting
Recording the Last Crash
Step 9
Step 10
In the Actions area of the Bootstrap Process Recording area, click Download Recording .
Follow the instructions to download.
Note The file is saved in a
.dvc
format to a local drive. You can view this recording using KVM player or an offline player. Every time you choose Download Recording option, the last boot process is recorded, it autogenerate the file name, and save it in the path specified earlier.
Once the download is complete, you can select the file that you want play the video of the recording, and click
Open .
A DVR Player Controls window opens and plays the video of the selected file.
Recording the Last Crash
Procedure
Step 1
Step 2
Step 3
Step 4
Step 5
Step 6
Step 7
Step 8
In the Navigation pane, click the Compute menu.
In the work pane, click the TroubleShooting tab.
In the Crash Recording area of the Troubleshooting tab, check the Enable Recording check-box.
Caution This task is for troubleshooting purpose, and might impact Cisco IMC performance if it is enabled all the time.
Click Save Changes .
Capture Recording button in the Actions area is enabled.
(Optional) In the Actions area, click Capture Recording , to capture the recording of the system that crashed automatically.
Note If you choose this option, it overwrites the existing crash records file. Click OK to continue.
Click Play Recording in the Actions area to view the recording of the operations that ran on the server.
A confirmation dialog box with instructions on supported Java version appears.
Review the instructions and click Ok .
The DVR Player Controls dialog box appears. This dialog box plays the recording of the operations that ran on the server in the last few minutes. This recording can be reviewed to analyze the factors that caused system to crash.
In the Actions area of the Crash Recording area, click Download Recording .
Follow the instructions to download.
Note The file is saved in a
.dvc
format to a local drive. You can view this recording using KVM player or an offline player. Every time you choose Download Recording option, the last crash process is recorded, it autogenerate the file name, and save it in the path specified earlier.
350
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
Troubleshooting
Downloading a DVR Player
Step 9 Once the download is complete, you can select the file that you want play the video of the recording, and click
Open .
A DVR Player Controls window opens and plays the video of the selected file.
Downloading a DVR Player
Procedure
Step 1
Step 2
Step 3
Step 4
Step 5
Step 6
Step 7
In the Navigation pane, click the Server tab.
On the Server tab, click Troubleshooting .
In the Player area of the Troubleshooting tab, click Download Player .
Follow the instructions to download. These files are saved to your local drive as a zipped file in a .tgz file format.
The offline player is stored for Windows, Linux, and MAC.
Extract the zip file. The zip file generally gets saved below the bootstrap file, and its name follows the format offline.tgz
Open the script file that you want to review the video recording.
Note If you want to play the recording for Windows, then ensure that the Java version running on your system and in the script file are the same. If the Windows script file fails to play the recording, then follow these steps: a) Extract the Windows script file to your desktop.
b) Open the file using notepad.
c) Search for jre, and replace the Java version to match the version running on your system. By default, the
Java version is set to jre7.
d) Save the file.
After you update the Java version, you can delete the extracted files from your desktop.
Note Verification of Java version is required only for Windows OS. For Linux and MAC, the Java version is picked automatically.
Navigate to the folder in which these files are downloaded and open the script file that you want to play the video recording.
The DVR player is launched, playing the video of the operations that ran on the server.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
351
Troubleshooting
Playing a Recorded Video Using the DVR Player on the KVM Console
Playing a Recorded Video Using the DVR Player on the KVM
Console
Procedure
Step 1
Step 2
Step 3
Step 4
Step 5
Step 6
Step 7
In the Navigation pane, click the Server tab.
On the Server tab, click Sensors .
In the Remote Presence pane, click the Virtual KVM tab.
In the Actions area of the Virtual KVM tab, click Launch KVM Console .
Note You can also launch KVM console by clicking Launch KVM Console button on the toolbar displayed above the Work pane.
The KVM Console opens in a separate window.
On the KVM Console window, choose Tools > Recorder /Playback Controls .
A DVR Player Controls window opens.
On the DVR Player Controls window, click Open button.
Choose the file that you want to play the recording, and click Open .
The DVR player is launched, playing the video of the operations that ran on the server.
352
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
A P P E N D I X
A
BIOS Parameters by Server Model
•
•
C220 M5, C240 M5, C240 SD M5, and C480 M5 Servers, on page 368
•
•
C220 M4 and C240 M4 Servers, on page 418
For C125 Servers
Server Management Tab
Note BIOS parameters listed in this tab may vary depending on the server.
Table 12: BIOS Parameters in Server Management Tab
Name
Reboot Host Immediately checkbox
OS Boot Watchdog Timer Policy drop-down list
Description
If the Reboot Host Immediately check box is checked, the server is rebooted immediately and the new BIOS settings go into effect. Otherwise the changes are saved until the server is manually rebooted.
What action the system takes if the watchdog timer expires. This can be one of the following:
• Power Off —The server is powered off if the watchdog timer expires during OS boot.
• Reset —The server is reset if the watchdog timer expires during OS boot.
Note This option is only applicable if you enable the OS Boot Watchdog Timer.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
353
BIOS Parameters by Server Model
Name
OS Watchdog Timer drop-down list
Baud Rate drop-down list
Console Redirection drop-down list
BIOS Parameters by Server Model
Description
Whether the BIOS programs the watchdog timer with a specified timeout value. This can be one of the following:
• Disabled —The watchdog timer is not used to track how long the server takes to boot.
• Enabled —The watchdog timer tracks how long the server takes to boot. If the server does not boot within the length of time specified in the
OS Boot Watchdog Timer Timeout field, the
Cisco IMC logs an error and takes the action specified in the OS Boot Watchdog Policy field.
What Baud rate is used for the serial port transmission speed. If you disable Console Redirection, this option is not available. This can be one of the following:
• 9.6k
—A 9,600 Baud rate is used.
• 19.2k
—A 19,200 Baud rate is used.
• 38.4k
—A 38,400 Baud rate is used.
• 57.6k
—A 57,600 Baud rate is used.
• 115.2k
—A 115,200 Baud rate is used.
This setting must match the setting on the remote terminal application.
Allows a serial port to be used for console redirection during POST and BIOS booting. After the OS has booted, console redirection is irrelevant. This can be one of the following:
• Serial Port A —Enables console redirection on serial port A during POST.
• Serial Port B —Enables console redirection on serial port B during POST.
• Disabled —No console redirection occurs during
POST.
354
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
BIOS Parameters by Server Model
Name
BIOS Techlog Level
OptionROM Launch Optimization
FRB 2 Timer drop-down list
BIOS Parameters by Server Model
Description
This option denotes the type of messages in BIOS tech log file.
The log file can be one of the following types:
• Minimum - Critical messages will be displayed in the log file.
• Normal - Warning and loading messages will be displayed in the log file.
• Maximum - Normal and information related messages will be displayed in the log file.
Default value: Minimum .
Note This option is mainly for internal debugging purposes.
Note To disable the Fast Boot option, the end user must set the following tokens as mentioned below:
BIOS Techlog level to Normal
OptionROM Launch Optimization to
Disabled .
When this option is Enabled , the OptionROMs only for the controllers present in the boot order policy will be launched.
Note Onboard storage controllers though not listed in the boot order policy will have the
OptionROM launched.
When this option is Disabled , all the OptionROMs will be launched.
Default value: Enabled
Whether the FRB2 timer is used by Cisco IMC to recover the system if it hangs during POST. This can be one of the following:
• Disabled —The FRB2 timer is not used.
• Enabled —The FRB2 timer is started during
POST and used to recover the system if necessary.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
355
BIOS Parameters by Server Model
BIOS Parameters by Server Model
Name
OS Watchdog Timer Timeout drop-down list
Flow Control
Terminal type drop-down list drop-down list
Description
If OS does not boot within the specified time, OS watchdog timer expires and system takes action according to timer policy. This can be one of the following:
• 5 Minutes —The OS watchdog timer expires 5 minutes after it begins to boot.
• 10 Minutes —The OS watchdog timer expires
10 minutes after it begins to boot.
• 15 Minutes —The OS watchdog timer expires
15 minutes after it begins to boot.
• 20 Minutes —The OS watchdog timer expires
20 minutes after it begins to boot.
Note This option is only applicable if you enable the OS Boot Watchdog Timer.
Whether a handshake protocol is used for flow control.
Request to Send / Clear to Send (RTS/CTS) helps to reduce frame collisions that can be introduced by a hidden terminal problem. This can be one of the following:
• None —No flow control is used.
• RTS/CTS —RTS/CTS is used for flow control.
Note This setting must match the setting on the remote terminal application.
What type of character formatting is used for console redirection. This can be one of the following:
• PC-ANSI —The PC-ANSI terminal font is used.
• VT100 —A supported VT100 video terminal and its character set are used.
• VT100-PLUS —A supported VT100-plus video terminal and its character set are used.
• VT-UTF8 —A video terminal with the UTF-8 character set is used.
356
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
BIOS Parameters by Server Model
Security Tab
Name
CDN Control drop-down list
Description
Whether the Ethernet Network naming convention is according to Consistent Device Naming (CDN) or the traditional way of naming conventions. This can be one of the following:
• Disabled — CDN support for VIC cards is disabled.
• Enabled — CDN support is enabled for VIC cards.
Security Tab
Note BIOS parameters listed in this tab may vary depending on the server.
Table 13: BIOS Parameters in Security Tab
Name
Reboot Host Immediately checkbox
Description
If the Reboot Host Immediately check box is checked, the server is rebooted immediately and the new BIOS settings go into effect. Otherwise the changes are saved until the server is manually rebooted.
Trusted Platform Module Support drop-down list Trusted Platform Module (TPM ) is a microchip designed to provide basic security-related functions primarily involving encryption keys. This option allows you to control the TPM Security Device support for the system. It can be one of the following:
• Disabled —The server does not use the TPM.
• Enabled —The server uses the TPM.
Note Contact your operating system vendor to make sure the operating system supports this feature.
Power on Password drop-down list This token requires that you set a BIOS password before using the F2 BIOS configuration. If enabled, password needs to be validated before you access
BIOS functions such as IO configuration, BIOS set up, and booting to an operating system using BIOS.
It can be one of the following:
• Disabled —Support is disabled.
• Enabled —Support is enabled.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
357
BIOS Parameters by Server Model
Memory Tab
Memory Tab
Note BIOS parameters listed in this tab may vary depending on the server.
Table 14: BIOS Parameters in Memory Tab
Name
Reboot Host Immediately checkbox
Above 4G Decoding drop-down list
Description
Upon checking, reboots the host server immediately.
You must check the checkbox after saving changes.
Enables or disables MMIO above 4GB or not. This can be one of the following:
• Disabled —The server does not map I/O of 64-bit
PCI devices to 4GB or greater address space.
• Enabled —The server maps I/O of 64-bit PCI devices to 4GB or greater address space.
Note PCI devices that are 64-bit compliant but use a legacy option ROM may not function correctly with this setting enabled.
358
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
BIOS Parameters by Server Model
BIOS Parameters by Server Model
Name
Memory Interleaving drop-down list
Memory Interleaving Size drop-down list
Description
Whether the AMD CPU interleaves the physical memory so that the memory can be accessed while another is being refreshed. This controls fabric level memory interleaving. Channel, die and socket have requirements based on memory populations and will be ignored if the memory does not support the selected option.This can be one of the following:
• Auto —The CPU determines how to interleave memory.
• Channel —Interleaves the physical address space over multiple channels, as opposed to each channel owning single consecutive address spaces.
• Die —Interleaves the physical address space over multiple dies, as opposed to each die owning single consecutive address spaces.
• None —Consecutive memory blocks are accessed from the same physical memory.
• Socket —Interleaves the physical address space over multiple sockets, as opposed to each socket owning single consecutive address spaces.
• Platform Default —The BIOS uses the value for this attribute contained in the BIOS defaults for the server type and vendor.
Determines the size of the memory blocks to be interleaved. It also determines the starting address of the interleave (bit 8,9,10 or 11). This can be one of the following:
• 1 KB
• 2 KB
• 256 Bytes
• 512 Bytes
• Auto —The CPU determines the size of the memory block.
• Platform Default —The BIOS uses the value for this attribute contained in the BIOS defaults for the server type and vendor.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
359
BIOS Parameters by Server Model
BIOS Parameters by Server Model
Name
Chipselect Interleaving drop-down list
Bank Group Swap
IOMMU drop-down list drop-down list
Description
Whether memory blocks across the DRAM chip selects for node 0 are interleaved. This can be one of the following:
• Auto —The CPU automatically determines how to interleave chip selects.
• Disabled —Chip selects are not interleaved within the memory controller.
• Platform Default —The BIOS uses the value for this attribute contained in the BIOS defaults for the server type and vendor.
Determines how physical addresses are assigned to applications. This can be one of the following:
• Auto —The CPU automatically determines how to assign physical addresses to applications.
• Disabled —Bank group swap is not used.
• Enabled —Bank group swap is used to improve the performance of applications.
• Platform Default —The BIOS uses the value for this attribute contained in the BIOS defaults for the server type and vendor.
Input Output Memory Management Unit (IOMMU) allows AMD processors to map virtual addresses to physical addresses. This can be one of the following:
• Auto —The CPU determines how map these addresses.
• Disabled —IOMMU is not used.
• Enabled —Address mapping takes place through the IOMMU.
• Platform Default —The BIOS uses the value for this attribute contained in the BIOS defaults for the server type and vendor.
360
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
BIOS Parameters by Server Model
Name
SMEE drop-down list
TSME drop-down list
SEV drop-down list
BIOS Parameters by Server Model
Description
Whether the processor uses the Secure Memory
Encryption Enable (SMEE) function, which provides memory encryption support. This can be one of the following:
• Disabled —The processor does not use the SMEE function.
• Enabled —The processor uses the SMEE function.
• Platform Default —The BIOS uses the value for this attribute contained in the BIOS defaults for the server type and vendor.
Whether the processor uses the Transparent Secure
Memory Encryption (TSME) function, which provides memory encryption support. This can be one of the following:
• Disabled —The processor does not use the TSME function.
• Enabled —The processor uses the TSME function.
• Auto —The BIOS uses the value for this attribute contained in the BIOS defaults for the server type and vendor.
Enables running encrypted virtual machines (VMs) in which the code and data of the VM are isolated.
This can be one of the following:
• 253 ASIDs —The value is set to 253 Minimum
Address Space Identifier (ASIDs).
• 509 ASIDs —The value is set to 509 Minimum
Address Space Identifier (ASIDs).
• Auto —The BIOS uses the value for this attribute contained in the BIOS defaults for the server type and vendor.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
361
BIOS Parameters by Server Model
I/O Tab
Name
DRAM SW Thermal Throttling drop-down list
Burst and Postponed Refresh drop-down list
Description
Provides a protective mechanism to ensure that the software functions within the temperature limits.
When the temperature exceeds the maximum threshold value, the performance is permitted to drop allowing to cool down to the minimum threshold value. This can be one of the following:
• Disabled —The processor does not use the function.
• Enabled —The processor uses the function.
• Auto —The BIOS uses the value for this attribute contained in the BIOS defaults for the server type and vendor.
• Disabled —The processor does not use the function.
• Enabled —The processor uses the function.
• Auto —The BIOS uses the value for this attribute contained in the BIOS defaults for the server type and vendor.
I/O Tab
Note BIOS parameters listed in this tab may vary depending on the server.
Table 15: BIOS Parameters in I/O Tab
Name
Reboot Host Immediately checkbox
Description
Upon checking, reboots the host server immediately. You must check the checkbox after saving changes.
Pcie Slotn Oprom drop-down list Whether the server can use the Option ROMs present in the PCIe card slot designated by n . This can be one of the following:
• Disabled —Option ROM for slot n is not available.
• Enabled —Option ROM for slot n is available.
362
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
BIOS Parameters by Server Model
BIOS Parameters by Server Model
Name Description
PCIe Slotn Link Speed drop-down list
System IO Controller n (SIOCn) add-on slot (designated by n ) link speed. This can be one of the following:
• Disabled —Slot is disabled, and the card is not enumerated.
• Auto — The default link speed. Link speed is automatically assigned.
• GEN1 —Link speed can reach up to first generation.
• GEN2 —Link speed can reach up to second generation.
• GEN3 —Link speed can reach up to third generation.
IPV6 PXE Support drop-down list Enables or disables IPV6 support for PXE. This can be one of the following
• Disabled —IPV6 PXE support is not available.
• Enabled —IPV6 PXE support is always available.
IPV4 PXE Support drop-down list Enables or disables IPV4 support for PXE. This can be one of the following
• Disabled —IPV4 PXE support is not available.
• Enabled —IPV4 PXE support is always available.
SR-IOV Support drop-down list Whether SR-IOV (Single Root I/O Virtualization) is enabled or disabled on the server. This can be one of the following:
• Disabled —SR-IOV is disabled.
• Enabled —SR-IOV is enabled.
Front NVME n OptionROM drop-down list
This options allows you to control the Option ROM execution of the
PCIe adapter connected to the SSD:NVMe n slot. This can be one of the following:
• Disabled —Does not execute Option ROM of the PCIe adapter connected to the SSD:NVMe n slot.
• Enabled —Executes Option ROM of the PCIe adapter connected to the SSD:NVMe n slot
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
363
BIOS Parameters by Server Model
Power/Performance Tab
Name
Front NVME n Link Speed drop-down list
Description
Link speed for NVMe front slot n . This can be one of the following:
• Disabled —Slot is disabled, and the card is not enumerated.
• Auto —The default link speed. Link speed is automatically assigned.
• GEN1 —Link speed can reach up to first generation.
• GEN2 —Link speed can reach up to second generation.
• GEN3 —Link speed can reach up to third generation.
PCIe Slot MSTOR RAID
OptionROM drop-down list
Whether the server can use the Option ROMs present in the PCIe
MSTOR RAID. This can be one of the following:
• Disabled —Option ROM is not available.
• Enabled —Option ROM is available.
PCIe ARI Support drop-down list Beginning with release 4.1(2a), Cisco IMC supports PCIe Alternative
Routing ID (ARI) Interpretation feature. The PCIe specification supports greater numbers of virtual funtions through the implementation of ARI, which reinterprets the device number field in the PCIe header allowing for more than eight functions. This can be one of the following:
• Disabled —PCIe ARI Support is not available.
• Enabled —PCIe ARI Support is available.
• Auto —PCIe ARI Support is in auto mode.
IPV6 HTTP Support drop-down list
Enables or disables IPv6 support for HTTP. This can be one of the following:
• Disabled —IPv6 HTTP support is not available.
• Enabled —IPv6 HTTP support is always available.
IPV4 HTTP Support drop-down list
Enables or disables IPv4 support for HTTP. This can be one of the following:
• Disabled —IPv4 HTTP support is not available.
• Enabled —IPv4 HTTP support is always available.
Power/Performance Tab
Note BIOS parameters listed in this tab may vary depending on the server.
364
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
BIOS Parameters by Server Model
BIOS Parameters by Server Model
Table 16: BIOS Parameters in Power/Performance Tab
Name
Reboot Host Immediately checkbox
Core Performance Boost drop-down list
Description
Upon checking, reboots the host server immediately. You must check the checkbox after saving changes.
Whether the AMD processor increases its frequency on some cores when it is idle or not being used much. This can be one of the following:
• Auto —The CPU automatically determines how to boost performance.
• Disabled —Core performance boost is disabled.
• Platform Default —The BIOS uses the value for this attribute contained in the BIOS defaults for the server type and vendor.
Global C-state Control drop-down list
Whether the AMD processors control IO-based C-state generation and
DF C-states This can be one of the following:
• Auto —The CPU automatically determines how to control IO-based
C-state generation.
• Disabled —Global C-state control is disabled.
• Enabled —Global C-state control is enabled.
• Platform Default —The BIOS uses the value for this attribute contained in the BIOS defaults for the server type and vendor.
L1 Stream HW Prefetcher drop-down list
Whether the processor allows the AMD hardware prefetcher to speculatively fetch streams of data and instruction from memory into the L1 cache when necessary. This can be one of the following:
• Auto —The CPU determines how to place data from I/O devices into the processor cache.
• Disabled —The hardware prefetcher is not used.
• Enabled —The processor uses the hardware prefetcher when cache issues are detected.
• Platform Default —The BIOS uses the value for this attribute contained in the BIOS defaults for the server type and vendor.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
365
BIOS Parameters by Server Model
Processor Tab
Processor Tab
Name
L2 Stream HW Prefetcher drop-down list
Description
Whether the processor allows the AMD hardware prefetcher to speculatively fetch streams of data and instruction from memory into the L2 cache when necessary. This can be one of the following:
• Auto —The CPU determines how to place data from I/O devices into the processor cache.
• Disabled —The hardware prefetcher is not used.
• Enabled —The processor uses the hardware prefetcher when cache issues are detected.
• Platform Default —The BIOS uses the value for this attribute contained in the BIOS defaults for the server type and vendor.
Determinism Slider drop-down list
Allows AMD processors to determine how to operate. This can be one of the following:
• Auto —The CPU automatically uses default power determinism settings.
• Performance —Processor operates at the best performance in a consistent manner.
• Power —Processor operates at the maximum allowable performance on a per die basis.
• Platform Default —The BIOS uses the value for this attribute contained in the BIOS defaults for the server type and vendor.
Note BIOS parameters listed in this tab may vary depending on the server.
Table 17: BIOS Parameters in Processor Tab
Name
Reboot Host Immediately checkbox
Description
If the Reboot Host Immediately check box is checked, the server is rebooted immediately and the new BIOS settings go into effect. Otherwise the changes are saved until the server is manually rebooted.
366
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
BIOS Parameters by Server Model
Name
SMT Mode drop-down list
SVM Mode drop-down list
BIOS Parameters by Server Model
Description
Whether the processor uses AMD Simultaneous
MultiThreading Technology, which allows multithreaded software applications to execute threads in parallel within each processor. This can be one of the following:
• Auto —The processor allows for the parallel execution of multiple threads.
• Off —The processor does not permit multithreading.
• Platform Default —The BIOS uses the value for this attribute contained in the BIOS defaults for the server type and vendor.
Whether the processor uses AMD Secure Virtual
Machine Technology. This can be one of the following: This can be one of the following:
• Disabled —The processor does not use SVM
Technology.
• Enabled —The processor uses SVM Technology.
• Platform Default —The BIOS uses the value for this attribute contained in the BIOS defaults for the server type and vendor.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
367
BIOS Parameters by Server Model
C220 M5, C240 M5, C240 SD M5, and C480 M5 Servers
Name
Downcore control drop-down list
Description
Allows AMD processors to disable cores and, thus, select how many cores to enable. This can be one of the following:
• FOUR (2+2)—Two cores enabled on each CPU complex.
• FOUR (4+0)—Four cores enabled on one CPU complex.
• SIX (3+3)—Three cores enabled on each CPU complex.
• THREE (3+0)—Three cores enabled on one CPU complex.
• TWO (1+1)—Two cores enabled on each CPU complex.
• TWO (2+0)—Two cores enabled on one CPU complex.
• Auto —The CPU determines how many cores need to be enabled.
• Platform Default —The BIOS uses the value for this attribute contained in the BIOS defaults for the server type and vendor.
C220 M5, C240 M5, C240 SD M5, and C480 M5 Servers
I/O Tab
Note BIOS parameters listed in this tab may vary depending on the server.
Table 18: BIOS Parameters in I/O Tab
Name
Reboot Host
Immediately checkbox
Legacy USB Support drop-down list
Description
Upon checking, reboots the host server immediately. You must check the checkbox after saving changes.
Whether the system supports legacy USB devices. This can be one of the following:
• Disabled —USB devices are only available to EFI applications.
• Enabled —Legacy USB support is always available.
368
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
BIOS Parameters by Server Model
BIOS Parameters by Server Model
Name Description
Intel VT for directed IO drop-down list
Whether the processor uses Intel Virtualization Technology (VT), which allows a platform to run multiple operating systems and applications in independent partitions. This can be one of the following:
• Disabled —The processor does not permit virtualization.
• Enabled —The processor allows multiple operating systems in independent partitions.
Note If you change this option, you must power cycle the server before the setting takes effect.
Intel VTD coherency support drop-down list
Whether the processor supports Intel VT-d Coherency. This can be one of the following:
• Disabled —The processor does not support coherency.
• Enabled —The processor uses VT-d Coherency as required.
Intel VTD ATS support drop-down list
Whether the processor supports Intel VT-d Address Translation Services (ATS).
This can be one of the following:
• Disabled —The processor does not support ATS.
• Enabled —The processor uses VT-d ATS as required.
VMD Enable drop-down list
Intel Volume Management Device (VMD) is for PCIe NVMe SSDs that provides hardware logic to manage and aggregate NVMe SSDs.
This can be one the following:
• Enabled — Enables benefits like robust surprise hot-plug, status LED management.
• Disabled — Disables benefits like robust surprise hot-plug, status LED management.
Default value: Disabled .
Refer Intel ®
(Intel ®
Virtual RAID on CPU User Guide
VROC) to configure VMD.
and Intel ® Virtual RAID on CPU
Details of VMD supported and unsupported ports for Cisco UCS C480 M5 servers:
Cisco UCS C480 NVMe SKU (32 drive NVME System)
• DMI connected ports 7, 8, and 23 do not support VMD.
• All other twenty nine ports support VMD.
Cisco UCS C480 Non-NVMe SKU
• DMI connected ports 1, 2, and 18 do not support VMD.
• Ports 7, 8, 9, 10, 15, 16, 17, 23, 24 support VMD.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
369
BIOS Parameters by Server Model
BIOS Parameters by Server Model
Name
All Onboard LOM
Oprom drop-down list
Description
Whether Option ROM is available on all LOM ports. This can be one of the following:
• Disabled —Option ROM is disabled on all the ports.
• Enabled —Option ROM is enabled on all the ports.
Onboard LOM Port0
Oprom drop-down list
Whether Option ROM is available on the LOM port 0. This can be one of the following:
• Disabled —Option ROM is not available on LOM port 0.
• Enabled —Option ROM is available on LOM port 0.
Onboard LOM Port1
Oprom drop-down list
Whether Option ROM is available on the LOM port 1. This can be one of the following:
• Disabled —Option ROM is not available on LOM port 1.
• Enabled —Option ROM is available on LOM port 1.
Pcie Slotn Oprom drop-down list
MLOM Oprom drop-down list
Whether the server can use the Option ROMs present in the PCIe card slot designated by n . This can be one of the following:
• Disabled —Option ROM for slot n is not available.
• Enabled —Option ROM for slot n is available.
This options allows you to control the Option ROM execution of the PCIe adapter connected to the MLOM slot. This can be one of the following:
• Disabled —Does not execute Option ROM of the PCIe adapter connected to the MLOM slot.
• Enabled —Executes Option ROM of the PCIe adapter connected to the
MLOM slot.
HBA Oprom drop-down list
This options allows you to control the Option ROM execution of the PCIe adapter connected to the HBA slot. This can be one of the following:
• Disabled —Does not execute Option ROM of the PCIe adapter connected to the HBA slot.
• Enabled —Executes Option ROM of the PCIe adapter connected to the
HBA slot.
Front NVME1 Oprom drop-down list
This options allows you to control the Option ROM execution of the PCIe adapter connected to the SSD:NVMe1 slot. This can be one of the following:
• Disabled —Does not execute Option ROM of the PCIe adapter connected to the SSD:NVMe1 slot.
• Enabled —Executes Option ROM of the PCIe adapter connected to the
SSD:NVMe1 slot
370
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
BIOS Parameters by Server Model
BIOS Parameters by Server Model
Name
Front NVME2 Oprom drop-down list
Description
This options allows you to control the Option ROM execution of the PCIe adapter connected to the SSD:NVMe2 slot. This can be one of the following:
• Disabled —Does not execute Option ROM of the PCIe adapter connected to the SSD:NVMe2 slot.
• Enabled —Executes Option ROM of the PCIe adapter connected to the
SSD:NVMe2 slot
HBA Link Speed drop-down list
MLOM Link Speed drop-down list
This option allows you to restrict the maximum speed of an adapter card installed in PCIe HBA slot. This can be one of the following:
• Disabled —The maximum speed is not restricted.
• Auto —System selects the maximum speed allowed.
• GEN1 —2.5GT/s (gigatransfers per second) is the maximum speed allowed.
• GEN2 —5GT/s is the maximum speed allowed.
• GEN3 —8GT/s is the maximum speed allowed.
This option allows you to restrict the maximum speed of an adapter card installed in PCIe MLOM slot. This can be one of the following:
• Disabled —The maximum speed is not restricted.
• Auto —System selects the maximum speed allowed.
• GEN1 —2.5GT/s (gigatransfers per second) is the maximum speed allowed.
• GEN2 —5GT/s is the maximum speed allowed.
• GEN3 —8GT/s is the maximum speed allowed.
PCIe Slotn Link Speed drop-down list
System IO Controller n (SIOCn) add-on slot (designated by n ) link speed. This can be one of the following:
• Disabled —Slot is disabled, and the card is not enumerated.
• Auto — The default link speed. Link speed is automatically assigned.
• GEN1 —Link speed can reach up to first generation.
• GEN2 —Link speed can reach up to second generation.
• GEN3 —Link speed can reach up to third generation.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
371
BIOS Parameters by Server Model
BIOS Parameters by Server Model
Name
Front NVME1 Link
Speed drop-down list
Front NVME2 Link
Speed drop-down list
Rear NVME1 Link
Speed drop-down list
Rear NVME2 Link
Speed drop-down list
Description
Link speed for NVMe front slot 1. This can be one of the following:
• Disabled —Slot is disabled, and the card is not enumerated.
• Auto —The default link speed. Link speed is automatically assigned.
• GEN1 —Link speed can reach up to first generation.
• GEN2 —Link speed can reach up to second generation.
• GEN3 —Link speed can reach up to third generation.
Link speed for NVMe front slot 2. This can be one of the following:
• Disabled —Slot is disabled, and the card is not enumerated.
• Auto —The default link speed. Link speed is automatically assigned.
• GEN1 —Link speed can reach up to first generation.
• GEN2 —Link speed can reach up to second generation.
• GEN3 —Link speed can reach up to third generation.
Link speed for NVMe rear slot 1. This can be one of the following:
• Disabled —Slot is disabled, and the card is not enumerated.
• Auto —The default link speed. Link speed is automatically assigned.
• GEN1 —Link speed can reach up to first generation.
• GEN2 —Link speed can reach up to second generation.
• GEN3 —Link speed can reach up to third generation.
Link speed for NVMe rear slot 2. This can be one of the following:
• Disabled —Slot is disabled, and the card is not enumerated.
• Auto —The default link speed. Link speed is automatically assigned.
• GEN1 —Link speed can reach up to first generation.
• GEN2 —Link speed can reach up to second generation.
• GEN3 —Link speed can reach up to third generation.
372
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
BIOS Parameters by Server Model
BIOS Parameters by Server Model
Name Description
VGA Priority drop-down list
Allows you to set the priority for VGA graphics devices if multiple VGA devices are found in the system. This can be one of the following:
• OnBoard —Priority is given to the onboard VGA device. BIOS post screen and OS boot are driven through the onboard VGA port.
• OffBoard —Priority is given to the PCIE Graphics adapter. BIOS post screen and OS boot are driven through the external graphics adapter port.
• OnBoardDisabled —Priority is given to the PCIe Graphics adapter, and the onboard VGA device is disabled. The vKVM does not function when the onboard VGA is disabled.
P-SATA OptionROM drop-down list
Allows you to select the PCH SATA optionROM mode. This can be one of the following:
• LSI SW Raid — Sets both SATA and sSATA controllers to raid mode for
LSI SW Raid.
• Disabled — Disables both SATA and sSATA controllers.
M2.SATA OptionROM drop-down list
Mode of operation of Serial Advanced Technology Attachment (SATA) Solid
State Drives (SSD). This can be one of the following:
• AHCI —
Sets both SATA and sSATA controllers to AHCI mode.
• LSI SW Raid — Sets both SATA and sSATA controllers to raid mode for
LSI SW Raid.
• Disabled — Disables both SATA and sSATA controllers.
USB Port Rear drop-down list
USB Port Front drop-down list
Whether the rear panel USB devices are enabled or disabled. This can be one of the following
• Disabled — Disables the rear panel USB ports. Devices connected to these ports are not detected by the BIOS and operating system.
• Enabled — Enables the rear panel USB ports. Devices connected to these ports are detected by the BIOS and operating system.
Whether the front panel USB devices are enabled or disabled. This can be one of the following
• Disabled — Disables the front panel USB ports. Devices connected to these ports are not detected by the BIOS and operating system.
• Enabled — Enables the front panel USB ports. Devices connected to these ports are detected by the BIOS and operating system.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
373
BIOS Parameters by Server Model
BIOS Parameters by Server Model
Name
USB Port Internal drop-down list
USB Port KVM drop-down list
USB Port SD Card drop-down list
IPV6 PXE Support drop-down list
PCIe PLL SSC drop-down list
IPV4 PXE Support drop-down list
Description
Whether the internal USB devices are enabled or disabled. This can be one of the following
• Disabled — Disables the internal USB ports. Devices connected to these ports are not detected by the BIOS and operating system.
• Enabled — Enables the internal USB ports. Devices connected to these ports are detected by the BIOS and operating system.
Whether the vKVM ports are enabled or disabled. This can be one of the following
• Disabled — Disables the vKVM keyboard and/or mouse devices. Keyboard and/or mouse will not work in the KVM window.
• Enabled — Enables the vKVM keyboard and/or mouse devices.
Whether the SD card is enabled or disabled. This can be one of the following
• Disabled — Disables the SD card ports. Devices connected to these ports are not detected by the BIOS and operating system.
• Enabled — Enables the SD card ports. Devices connected to these ports are detected by the BIOS and operating system.
Enables or disables IPv6 support for PXE. This can be one of the following
• Disabled —IPv6 PXE support is not available.
• Enabled —IPv6 PXE support is always available.
Enable this feature to reduce EMI interference by down spreading clock 0.5%.
Disable this feature to centralize the clock without spreading.
This can be one of the following:
• Auto —EMI interference is auto adjusted.
Disabled —EMI interference is auto adjusted.
• ZeroPointFive —EMI interference is reduced by down spreading the clock
0.5%.
Enables or disables IPv4 support for PXE. This can be one of the following
• Disabled —IPv4 PXE support is not available.
• Enabled —IPv4 PXE support is always available.
374
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
BIOS Parameters by Server Model
Server Management Tab
Name
Network Stack drop-down list
External SSC enable drop-down list
PCIe Slot MSTOR
RAID OptionROM drop-down list
Description
This option allows you to monitor IPv6 and IPv4. This can be one of the following
• Disabled —Network Stack support is not available.
Note When disabled, the value set for IPV4 PXE Support does not impact the system.
• Enabled —Network Stack support is always available.
This option allows you to reduce the EMI of your motherboard by modulating the signals it generates so that the spikes are reduced to flatter curves.
This can be one of the following:
• Disabled —Clock Spread Spectrum support is not available.
• Enabled —Clock Spread Spectrum support is always available.
Whether the server can use the Option ROMs present in the PCIe MSTOR RAID.
This can be one of the following:
• Disabled —Option ROM is not available.
• Enabled —Option ROM is available.
Server Management Tab
Note BIOS parameters listed in this tab may vary depending on the server.
Table 19: BIOS Parameters in Server Management Tab
Name
Reboot Host Immediately checkbox
OS Boot Watchdog Timer Policy drop-down list
Description
If the Reboot Host Immediately check box is checked, the server is rebooted immediately and the new BIOS settings go into effect. Otherwise the changes are saved until the server is manually rebooted.
What action the system takes if the watchdog timer expires. This can be one of the following:
• Power Off —The server is powered off if the watchdog timer expires during OS boot.
• Reset —The server is reset if the watchdog timer expires during OS boot.
Note This option is only applicable if you enable the OS Boot Watchdog Timer.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
375
BIOS Parameters by Server Model
BIOS Parameters by Server Model
Name
OS Watchdog Timer drop-down list
OS Watchdog Timer Timeout drop-down list
Baud Rate drop-down list
Description
Whether the BIOS programs the watchdog timer with a specified timeout value. This can be one of the following:
• Disabled —The watchdog timer is not used to track how long the server takes to boot.
• Enabled —The watchdog timer tracks how long the server takes to boot. If the server does not boot within the length of time specified in the
OS Boot Watchdog Timer Timeout field, the
Cisco IMC logs an error and takes the action specified in the OS Boot Watchdog Policy field.
If OS does not boot within the specified time, OS watchdog timer expires and system takes action according to timer policy. This can be one of the following:
• 5 Minutes —The OS watchdog timer expires 5 minutes after it begins to boot.
• 10 Minutes —The OS watchdog timer expires
10 minutes after it begins to boot.
• 15 Minutes —The OS watchdog timer expires
15 minutes after it begins to boot.
• 20 Minutes —The OS watchdog timer expires
20 minutes after it begins to boot.
Note This option is only applicable if you enable the OS Boot Watchdog Timer.
What Baud rate is used for the serial port transmission speed. If you disable Console Redirection, this option is not available. This can be one of the following:
• 9.6k
—A 9,600 Baud rate is used.
• 19.2k
—A 19,200 Baud rate is used.
• 38.4k
—A 38,400 Baud rate is used.
• 57.6k
—A 57,600 Baud rate is used.
• 115.2k
—A 115,200 Baud rate is used.
This setting must match the setting on the remote terminal application.
376
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
BIOS Parameters by Server Model
Name
Console Redirection drop-down list
Adaptive Memory Training
BIOS Parameters by Server Model
Description
Allows a serial port to be used for console redirection during POST and BIOS booting. After the OS has booted, console redirection is irrelevant. This can be one of the following:
• Serial Port A —Enables console redirection on serial port A during POST.
• Serial Port B —Enables console redirection on serial port B during POST.
• Disabled —No console redirection occurs during
POST.
When this option is Enabled :
The Memory training will not happen in every boot but the BIOS will use the saved memory training result in every re-boot.
Some exceptions when memory training happens in every boot are:
BIOS update, CMOS reset, CPU or Memory configuration change, SPD or run-time uncorrectable error or the last boot has occurred more than 24 hours before.
When this option is Disabled , the Memory training happens in every boot.
Default value: Enabled .
Note To disable the Fast Boot option, the end user must set the following tokens as mentioned below:
Adaptive Memory Training to Disabled
BIOS Techlog level to Normal
OptionROM Launch Optimization to
Disabled .
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
377
BIOS Parameters by Server Model
BIOS Parameters by Server Model
Name
BIOS Techlog Level
OptionROM Launch Optimization
CDN Control
FRB 2 Timer drop-down list drop-down list
Description
This option denotes the type of messages in BIOS tech log file.
The log file can be one of the following types:
• Minimum - Critical messages will be displayed in the log file.
• Normal - Warning and loading messages will be displayed in the log file.
• Maximum - Normal and information related messages will be displayed in the log file.
Default value: Minimum .
Note This option is mainly for internal debugging purposes.
When this option is Enabled , the OptionROMs only for the controllers present in the boot order policy will be launched.
Note Some controllers such as Onboard storage controllers, Emulex FC adapters, and GPU controllers though not listed in the boot order policy will have the OptionROM launched.
When this option is Disabled , all the OptionROMs will be launched.
Default value: Enabled
Whether the Ethernet Network naming convention is according to Consistent Device Naming (CDN) or the traditional way of naming conventions. This can be one of the following:
• Disabled — CDN support for VIC cards is disabled
• Enabled — CDN support is enabled for VIC cards.
Whether the FRB2 timer is used by Cisco IMC to recover the system if it hangs during POST. This can be one of the following:
• Disabled —The FRB2 timer is not used.
• Enabled —The FRB2 timer is started during
POST and used to recover the system if necessary.
378
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
BIOS Parameters by Server Model
Security Tab
Name
Flow Control drop-down list
Terminal type drop-down list
Description
Whether a handshake protocol is used for flow control.
Request to Send / Clear to Send (RTS/CTS) helps to reduce frame collisions that can be introduced by a hidden terminal problem. This can be one of the following:
• None —No flow control is used.
• RTS/CTS —RTS/CTS is used for flow control.
Note This setting must match the setting on the remote terminal application.
What type of character formatting is used for console redirection. This can be one of the following:
• PC-ANSI —The PC-ANSI terminal font is used.
• VT100 —A supported VT100 video terminal and its character set are used.
• VT100-PLUS —A supported VT100-plus video terminal and its character set are used.
• VT-UTF8 —A video terminal with the UTF-8 character set is used.
Security Tab
Note BIOS parameters listed in this tab may vary depending on the server.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
379
BIOS Parameters by Server Model
Processor Tab
Processor Tab
Table 20: BIOS Parameters in Security Tab
Name
Reboot Host Immediately checkbox
Description
If the Reboot Host Immediately check box is checked, the server is rebooted immediately and the new BIOS settings go into effect. Otherwise the changes are saved until the server is manually rebooted.
Trusted Platform Module Support drop-down list Trusted Platform Module (TPM ) is a microchip designed to provide basic security-related functions primarily involving encryption keys. This option allows you to control the TPM Security Device support for the system. It can be one of the following:
• Disabled —The server does not use the TPM.
• Enabled —The server uses the TPM.
Note Contact your operating system vendor to make sure the operating system supports this feature.
Power on Password drop-down list This token requires that you set a BIOS password before using the F2 BIOS configuration. If enabled, password needs to be validated before you access
BIOS functions such as IO configuration, BIOS set up, and booting to an operating system using BIOS.
It can be one of the following:
• Disabled —Support is disabled.
• Enabled —Support is enabled.
Note BIOS parameters listed in this tab may vary depending on the server.
380
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
BIOS Parameters by Server Model
BIOS Parameters by Server Model
Table 21: BIOS Parameters in Processor Tab
Name
Intel Virtualization Technology drop-down list
Extended Apic
Processor C1E drop-down list drop-down list
Description
Whether the processor uses Intel Virtualization
Technology (VT), which allows a platform to run multiple operating systems and applications in independent partitions. This can be one of the following:
• Disabled —The processor does not permit virtualization.
• Enabled —The processor allows multiple operating systems in independent partitions.
Allows you to enable or disable extended APIC support. This can be one of the following:
• Enabled —Enables APIC support
• Disabled —Disables APIC support.
Whether the CPU transitions to its minimum frequency when entering the C1 state. This can be one of the following:
• Disabled —The CPU continues to run at its maximum frequency in C1 state.
• Enabled —The CPU transitions to its minimum frequency. This option saves the maximum amount of power in C1 state.
Note This option is available only on some
C-Series servers.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
381
BIOS Parameters by Server Model
Name
Processor C6 Report drop-down list
Execute Disable Bit drop-down list
BIOS Parameters by Server Model
Description
Whether the BIOS sends the C6 report to the operating system. When the OS receives the report, it can transition the processor into the lower C6 power state to decrease energy usage while maintaining optimal processor performance. This can be one of the following:
• Disabled —The BIOS does not send the C6 report.
• Enabled —The BIOS sends the C6 report, allowing the OS to transition the processor to the
C6 low power state.
Note
Note
CPUPowerManagement must be set to
Custom or the server ignores the setting for this parameter.
This option is available only on some
C-Series servers.
Classifies memory areas on the server to specify where application code can execute. As a result of this classification, the processor disables code execution if a malicious worm attempts to insert code in the buffer. This setting helps to prevent damage, worm propagation, and certain classes of malicious buffer overflow attacks. This can be one of the following:
• Disabled —The processor does not classify memory areas.
• Enabled —The processor classifies memory areas.
Note Contact your operating system vendor to make sure the operating system supports this feature.
382
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
BIOS Parameters by Server Model
BIOS Parameters by Server Model
Name
Intel Turbo Boost Tech drop-down list
Enhanced Intel SpeedStep Tech drop-down list
Intel HyperThreading Tech drop-down list
Description
Whether the processor uses Intel Turbo Boost
Technology, which allows the processor to automatically increase its frequency if it is running below power, temperature, or voltage specifications.
This can be one of the following:
• Disabled —The processor does not increase its frequency automatically.
• Enabled —The processor utilizes Turbo Boost
Technology if required.
Note CPUPowerManagement must be set to
Custom or the server ignores the setting for this parameter.
Whether the processor uses Enhanced Intel SpeedStep
Technology, which allows the system to dynamically adjust processor voltage and core frequency. This technology can result in decreased average power consumption and decreased average heat production.
This can be one of the following:
• Disabled —The processor never dynamically adjusts its voltage or frequency.
• Enabled —The processor utilizes Enhanced Intel
SpeedStep Technology and enables all supported processor sleep states to further conserve power.
We recommend that you contact your operating system vendor to make sure the operating system supports this feature.
Note CPUPowerManagement must be set to
Custom or the server ignores the setting for this parameter.
Whether the processor uses Intel Hyper-Threading
Technology, which allows multithreaded software applications to execute threads in parallel within each processor. This can be one of the following:
• Disabled —The processor does not permit hyperthreading.
• Enabled —The processor allows for the parallel execution of multiple threads.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
383
BIOS Parameters by Server Model
BIOS Parameters by Server Model
Name
Workload Configuration drop-down list
Core MultiProcessing
Sub NUMA Clustering
IMC Interleave drop-down list drop-down list drop-down list
Description
This feature allows for workload optimization. The options are Balanced and I/O Sensitive:
• NUMA
• UMA
Allows you to disable one or more of the physical cores on the server. This can be one of the following:
• All —Enables all physical cores. This also enables Hyper Threading on the associated logical processor cores.
• 1 through 28 —Specifies the number of physical processor cores that can run on the server. Each physical core has an associated logical core.
Note Contact your operating system vendor to make sure the operating system supports this feature.
Whether the CPU supports sub NUMA clustering, in which the tag directory and the memory channel are always in the same region. This can be one of the following:
• Disabled — Sub NUMA clustering does not occur.
• Enabled — Sub NUMA clustering occurs.
• Auto — The BIOS determines what Sub NUMA clustering is done.
This BIOS option controls the interleaving between the Integrated Memory Controllers (IMCs).
• 1-way Interleave —There is no interleaving.
• 2-way Interleave —Addresses are interleaved between the two IMCs.
• Auto —CPU determines the IMC Interleaving mode.
384
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
BIOS Parameters by Server Model
BIOS Parameters by Server Model
Name
XPT Prefetch
UPI Prefetch drop-down list drop-down list
Description
Whether XPT prefetch is used to enable a read request sent to the last level cache to issue a copy of that request to the memory controller prefetcher. This can be one of the following:
• Disabled —The CPU does not use the XPT
Prefetch option.
• Enabled —The CPU enables the XPT prefetch option.
UPI prefetch is a mechanism to get the memory read started early on a DDR bus. This can be one of the following:
• Disabled —The processor does not preload any cache data.
• Enabled —The UPI prefetcher preloads the L1 cache with the data it determines to be the most relevant.
Energy Performance Bias Config drop-down list Allows you to determine whether system performance or energy efficiency is more important on this server.
This can be one of the following:
• Performance — The server provides all server components with full power at all times. This option maintains the highest level of performance and requires the greatest amount of power.
• Balanced Performance — The server provides all server components with enough power to keep a balance between performance and power.
• Balanced Power — The server provides all server components with enough power to keep a balance between performance and power.
• Power — The server provides all server components with maximum power to keep reduce power consumption.
Power Performance Tuning drop-down list Determines if the BIOS or Operating System can turn on the energy performance bias tuning. The options are BIOS and OS.
• BIOS —
Chooses BIOS for energy performance tuning.
• OS —
Chooses OS for energy performance tuning.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
385
BIOS Parameters by Server Model
Name
LLC Prefetch drop-down list
Package C State
BIOS Parameters by Server Model
Description
Whether the processor uses the LLC Prefetch mechanism to fetch the date into the LLC. This can be one of the following:
• Disabled —The processor does not preload any cache data.
• Enabled —The LLC prefetcher preloads the L1 cache with the data it determines to be the most relevant.
The amount of power available to the server components when they are idle. This can be one of the following:
• No Limit —The server may enter any available
C state.
• Auto —The CPU determines the physical elevation.
• C0 C1 State —The server provides all server components with full power at all times. This option maintains the highest level of performance and requires the greatest amount of power.
• C2 —When the CPU is idle, the system reduces the power consumption further than with the C1 option. This requires less power than C1 or C0, but it takes the server slightly longer to return to high performance mode.
• C6 Non Retention —When the CPU is idle, the system reduces the power consumption further than with the C3 option. This option saves more power than C0, C1, or C3, but there may be performance issues until the server returns to full power.
• C6 Retention —When the CPU is idle, the system reduces the power consumption further than with the C3 option. This option saves more power than C0, C1, or C3, but there may be performance issues until the server returns to full power.
386
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
BIOS Parameters by Server Model
BIOS Parameters by Server Model
Name
Hardware P-States
Intel Speed Select drop-down list drop-down list
Uncore Frequency Scaling drop-down list
Description
Enables processor Hardware P-State. This can be one of the following:
• Disabled —HWPM is disabled.
• HWPM Native Mode —HWPM native mode is enabled.
• HWPM OOB Mode —HWPM Out-Of-Box mode is enabled.
• Native Mode with no Legacy (only GUI)
Intel Speed Select modes will allow users to run the
CPU with different speed and cores.
This can be one of the following:
• Base — It will allow users to access maximum core and Thermal Design Power (TDP) ratio.
• Config 1 — It will allow users to access core and
TDP ratio lesser than Base .
• Config 2 — It will allow users to access core and
TDP ratio lesser than Config 1 .
Default value: Base .
This feature allows you configure the scaling of uncore frequency of the processor. This can be one of the following:
• Enabled —Uncore frequency of the processor scales up or down based on the load.
• Disabled —Uncore frequency of the processor remains fixed.
Refer Intel
®
Dear Customer Letter (DCL) to know the fixed higher and lower values for Uncore
Frequency Scaling .
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
387
BIOS Parameters by Server Model
Memory Tab
Name
Configurable TDP Level drop-down list
UPI Link Frequency Select drop-down list
Description
Configurable TDP Level feature allows adjustments in processor thermal design power values. By modifying the processor behavior and the performance levels, power consumption of a processor can be configured and TDP can be adjusted as the same time.
Hence, a processor operates at higher or lower performance levels, depending on the available cooling capacities and desired power consumption.
This can be one of the following:
• Normal
• Level_1
• Level_2
Refer Intel
®
Dear Customer Letter (DCL) to know the values for TDP level .
Note UPI Link Frequency Select token is not applicable for single socket configuration.
This feature allows you to configure the Intel Ultra
Path Interconnect (UPI) link speed between multiple sockets. This can be one of the following:
• Auto —This option configures the optimal link speed automatically.
• 9.6 GT/s —This option configures the optimal link speed at 9.6GT/s.
• 10.4 GT/s —This option configures the optimal link speed at 10.4GT/s
Memory Tab
Note BIOS parameters listed in this tab may vary depending on the server.
Table 22: BIOS Parameters in Memory Tab
Name
Reboot Host Immediately checkbox
Description
Upon checking, reboots the host server immediately.
You must check the checkbox after saving changes.
388
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
BIOS Parameters by Server Model
BIOS Parameters by Server Model
Name Description
Select Memory RAS configuration drop-down list Determines how the memory reliability, availability, and serviceability (RAS) is configured for the server.
This can be one of the following:
• Maximum Performance —System performance is optimized.
• ADDDC Sparing —Adaptive virtual lockstep is an algorithm implemented in the hardware and firmware to support the ADDDC mode. When selected, the system performance is optimized till the algorithm is activated. The algorithm is activated in case of DRAM device failure. Once the algorithm is activated, the virtual lockstep regions are activated to map out the failed region during run-time dynamically, and the performance impact is restricted at a region level.
• Mirror Mode 1LM —System reliability is optimized by using half the system memory as backup.
• Partial Mirror Mode 1LM —Partial DIMM
Mirroring creates a mirrored copy of a specific region of memory cells, rather than keeping the complete mirror copy. Partial Mirroring creates a mirrored region in memory map with the attributes of a partial mirror copy. Up to 50% of the total memory capacity can be mirrored, using up to 4 partial mirrors.
Above 4G Decoding drop-down list Enables or disables MMIO above 4GB or not. This can be one of the following:
• Disabled —The server does not map I/O of 64-bit
PCI devices to 4GB or greater address space.
• Enabled —The server maps I/O of 64-bit PCI devices to 4GB or greater address space.
Note PCI devices that are 64-bit compliant but use a legacy option ROM may not function correctly with this setting enabled.
DCPMM Firmware Downgrade drop-down list Whether the BIOS supports downgrading the DCPMM firmware. This can be one of the following:
• Disabled —Support is disabled.
• Enabled —Support is enabled.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
389
BIOS Parameters by Server Model
BIOS Parameters by Server Model
Name
Partial Memory Mirror Mode drop-down list
Partial Mirror percentage
Partial Mirror1 Size in GB
Partial Mirror2 Size in GB
Partial Mirror3 Size in GB
Partial Mirror4 Size in GB
Memory Size Limit in GB field field field field field field
Description
The partial memory size is either in percentage or in
GB. This can be one of the following:
• Percentage —The partial memory mirror is defined in percentage.
• Value in GB —The partial memory mirror is defined in GB.
• Disabled —Partial memory mirror is disabled.
Percentage of memory to mirror above 4GB.
Enter an integer between 0 and 50.
Size of the first partial memory mirror in GB.
Enter an integer between 0 and 65535.
Note The combined memory size of all the partial mirror should not exceed 50% of the physical memory size.
Size of the second partial memory mirror in GB.
Enter an integer between 0 and 65535.
Note The combined memory size of all the partial mirror should not exceed 50% of the physical memory size.
Size of the third partial memory mirror in GB.
Enter an integer between 0 and 65535.
Note The combined memory size of all the partial mirror should not exceed 50% of the physical memory size.
Size of the fourth partial memory mirror in GB.
Enter an integer between 0 and 65535.
Note The combined memory size of all the partial mirror should not exceed 50% of the physical memory size.
Use this option to reduce the size of the physical memory limit in GB.
Enter an integer between 0 and 65535.
390
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
BIOS Parameters by Server Model
Name
NUMA drop-down list
BME DMA Mitigation drop-down list
Select PPR Type
CR QoS drop-down list drop-down list
BIOS Parameters by Server Model
Description
Whether the BIOS supports Non-Uniform Memory
Access (NUMA). This can be one of the following:
• Disabled —Support is disabled.
• Enabled —Support is enabled.
Allows you to disable the PCI BME bit to mitigate the threat from an unauthorized external DMA. This can be one of the following:
• Disabled —PCI BME bit is disabled in the BIOS.
• Enabled —PCI BME bit is enabled in the BIOS.
Cisco IMC supports Hard-PPR , which permanently remaps accesses from a designated faulty row to a designated spare row.
This can be one of the following:
• Hard PPR —Support is enabled.
Note Hard PPR can be used only when
Memory RAS Configuration is set to ADDDC Sparing . For other RAS selections, this setting should be set to Disabled .
• Disabled —Support is disabled.
Enables you to select the CR QoS tuning.
This can be one of the following:
• Recipe 1 —For QoS knobs and is recommended for 2-2-2 memory configuration in active directory.
• Recipe 2 —For QoS knobs and is recommended for other memory configuration in active directory.
• Recipe 3 —For QoS knobs and is recommended for 1 DIMM per channel configuration.
• Disabled — CR QoS feature is disabled.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
391
BIOS Parameters by Server Model
BIOS Parameters by Server Model
Name
Snoopy mode for AD
CR FastGo Config drop-down list drop-down list
NVM Performance Setting drop-down list
Snoopy mode for 2LM drop-down list
Description
Enables new AD specific feature to avoid directory updates to DDRT memory from non-NUMA optimized workloads.
This can be one of the following:
• Disabled —Support is disabled.
• Enabled —Support is enabled.
Enables you to select CR QoS configuration profiles.
This can be one of the following:
• Default
• Option 1
• Option 2
• Option 3
• Option 4
• Option 5
• Auto
Enables you to configure NVM baseline performance settings depending on the workload behavior.
• BW Optimized
• Latency Optimized
• Balanced Profile
Enables you to avoid directory updates to far-memory from non-NUMA optimized workloads.
This can be one of the following:
• Disabled —Support is disabled.
• Enabled —Support is enabled.
392
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
BIOS Parameters by Server Model
BIOS Parameters by Server Model
Name Description
Memory Thermal Throttling Mode drop-down list This function is used for adjusting memory temperature. If memory temperature is excessively high after the function is enabled, the memory access rate is reduced and Baseboard Management Controller
(BMC) adjusts the fan to cool down the memory to avoid any DIMM damage.
This can be one of the following:
• Disabled —Support is disabled.
• CLTT with PECI —Enables Closed Loop
Thermal Throttling with Platform Environment
Control Interface.
Memory Refresh Rate drop-down list
Panic and High Watermark drop-down list
Enables you to increase or decrease memory refresh rate. Increasing the DRAM refresh rate reduces the maximum number of activates (hammers) that can occur before the next refresh.
This can be one of the following:
• 1X Refresh —Refresh rate is at minimum.
• 2X Refresh —Refresh is 2X faster.
When set to low, the memory controller does not postpone refreshes while Memory Refresh Rate is set to 1X Refresh .
This can be one of the following:
• Low —Refresh rate is set to low.
• High —Refresh rate is set to high.
Advanced Memory Test drop-down list Note This feature is applicable only to Samsung,
Hynix and Micron DIMMs.
You can enable advance DIMM testing during BIOS
POST using this feature. This can be one of the following:
• Disabled —Support is disabled.
• Enabled —Support is enabled.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
393
BIOS Parameters by Server Model
Power/Performance Tab
Power/Performance Tab
Note BIOS parameters listed in this tab may vary depending on the server.
Table 23: BIOS Parameters in Power/Performance Tab
Name
Reboot Host Immediately checkbox
Description
Upon checking, reboots the host server immediately. You must check the checkbox after saving changes.
Hardware Prefetcher drop-down list
Whether the processor allows the Intel hardware prefetcher to fetch streams of data and instruction from memory into the unified second-level cache when necessary. This can be one of the following:
• Disabled —The hardware prefetcher is not used.
• Enabled —The processor uses the hardware prefetcher when cache issues are detected.
Adjacent Cache Line Prefetcher drop-down list
Whether the processor fetches cache lines in even or odd pairs instead of fetching just the required line. This can be one of the following:
• Disabled —The processor only fetches the required line.
• Enabled —The processor fetches both the required line and its paired line.
DCU Streamer Prefetch drop-down list
Whether the processor uses the DCU IP Prefetch mechanism to analyze historical cache access patterns and preload the most relevant lines in the L1 cache. This can be one of the following:
• Disabled —The processor does not try to anticipate cache read requirements and only fetches explicitly requested lines.
• Enabled —The DCU prefetcher analyzes the cache read pattern and prefetches the next line in the cache if it determines that it may be needed.
DCU IP Prefetcher drop-down list Whether the processor uses the DCU IP Prefetch mechanism to analyze historical cache access patterns and preload the most relevant lines in the L1 cache. This can be one of the following:
• Disabled —The processor does not preload any cache data.
• Enabled —The DCU IP prefetcher preloads the L1 cache with the data it determines to be the most relevant.
394
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
BIOS Parameters by Server Model
C460 M4 Servers
Name Description
CPU Performance drop-down list Sets the CPU performance profile for the options listed above. This can be one of the following:
• Enterprise —All options are enabled.
• HPC —All options are enabled. This setting is also known as high performance computing.
• Hight Throughput —Only the DCU IP Prefetcher is enabled. The rest of the options are disabled.
• Custom —All performance profile options can be configured from the BIOS setup on the server. In addition, the Hardware Prefetcher and Adjacent Cache-Line Prefetch options can be configured as well.
C460 M4 Servers
Main Tab for C460 M4 Servers
Main BIOS Parameters
Name
Reboot Host Immediately checkbox
TPM Support
Power ON Password Support drop-down
Description
Upon checking, reboots the host server immediately. You must check the checkbox after saving changes.
TPM (Trusted Platform Module) is a microchip designed to provide basic security-related functions primarily involving encryption keys.
This option allows you to control the TPM Security Device support for the system. It can be one of the following:
• Disabled —The server does not use the TPM.
• Enabled —The server uses the TPM.
Note We recommend that you contact your operating system vendor to make sure the operating system supports this feature.
This token requires that you set a BIOS password before using the F2
BIOS configuration. If enabled, password needs to be validated before you access BIOS functions such as IO configuration, BIOS set up, and booting to an operating system using BIOS. It can be one of the following:
• Disabled —Support is disabled.
• Enabled —Support is enabled.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
395
BIOS Parameters by Server Model
Advanced Tab for C460 M4 Servers
Actions Area
Name
Save button
Reset button
Restore Defaults button
Description
Saves the settings for the BIOS parameter and closes the dialog box.
If the Reboot Host Immediately check box is checked, the server is rebooted immediately and the new BIOS settings go into effect.
Otherwise the changes are saved until the server is manually rebooted.
Resets the values for the BIOS parameters on all three tabs to the settings that were in effect when this dialog box was first opened.
Sets the BIOS parameters on all three tabs to their default settings.
Advanced Tab for C460 M4 Servers
Reboot Server Option
If you want your changes applied automatically after you click Save Changes , check the Reboot Host
Immediately check box. Cisco IMC immediately reboots the server and applies your changes.
If you want to apply your changes at a later time, clear the Reboot Host Immediately check box. Cisco IMC stores the changes and applies them the next time the server reboots.
Note If there are existing BIOS parameter changes pending, Cisco IMC automatically overwrites the stored values with the current settings when you click Save Changes .
Processor Configuration Parameters
Name
Intel Hyper-Threading Technology
Description
Whether the processor uses Intel Hyper-Threading Technology, which allows multithreaded software applications to execute threads in parallel within each processor. This can be one of the following:
• Disabled —The processor does not permit hyperthreading.
• Enabled —The processor allows for the parallel execution of multiple threads.
We recommend that you contact your operating system vendor to make sure the operating system supports this feature.
396
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
BIOS Parameters by Server Model
Name
Number of Enabled Cores
Execute Disable
Intel VT
Intel VT-d
BIOS Parameters by Server Model
Description
Allows you to disable one or more of the physical cores on the server. This can be one of the following:
• All —Enables all physical cores. This also enables Hyper
Threading on the associated logical processor cores.
• 1 through n —Specifies the number of physical processor cores that can run on the server. Each physical core has an associated logical core.
We recommend that you contact your operating system vendor to make sure the operating system supports this feature.
Classifies memory areas on the server to specify where application code can execute. As a result of this classification, the processor disables code execution if a malicious worm attempts to insert code in the buffer. This setting helps to prevent damage, worm propagation, and certain classes of malicious buffer overflow attacks. This can be one of the following:
• Disabled —The processor does not classify memory areas.
• Enabled —The processor classifies memory areas.
We recommend that you contact your operating system vendor to make sure the operating system supports this feature.
Whether the processor uses Intel Virtualization Technology
(VT), which allows a platform to run multiple operating systems and applications in independent partitions. This can be one of the following:
• Disabled —The processor does not permit virtualization.
• Enabled —The processor allows multiple operating systems in independent partitions.
Note If you change this option, you must power cycle the server before the setting takes effect.
Whether the processor uses Intel Virtualization Technology for
Directed I/O (VT-d). This can be one of the following:
• Disabled —The processor does not use virtualization technology.
• Enabled —The processor uses virtualization technology.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
397
BIOS Parameters by Server Model
BIOS Parameters by Server Model
Name Description
Intel(R) Interrupt Remapping drop-down list
Whether the processor supports Intel VT-d Interrupt Remapping.
This can be one of the following:
• Disabled —The processor does not support remapping.
• Enabled —The processor uses VT-d Interrupt Remapping as required.
Intel(R) Passthrough DMA drop-down list
Whether the processor supports Intel VT-d Pass-through DMA.
This can be one of the following:
• Disabled —The processor does not support pass-through
DMA.
• Enabled —The processor uses VT-d Pass-through DMA as required.
Intel VT-d Coherency Support
Intel VT-d ATS Support
Whether the processor supports Intel VT-d Coherency. This can be one of the following:
• Disabled —The processor does not support coherency.
• Enabled —The processor uses VT-d Coherency as required.
Whether the processor supports Intel VT-d Address Translation
Services (ATS). This can be one of the following:
• Disabled —The processor does not support ATS.
• Enabled —The processor uses VT-d ATS as required.
398
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
BIOS Parameters by Server Model
BIOS Parameters by Server Model
Name
CPU Performance
Hardware Prefetcher
Adjacent Cache Line Prefetcher
Description
Sets the CPU performance profile for the server. The performance profile consists of the following options:
• DCU Streamer Prefetcher
• DCU IP Prefetcher
• Hardware Prefetcher
• Adjacent Cache-Line Prefetch
This can be one of the following:
• Enterprise —All options are enabled.
• High Throughput —Only the DCU IP Prefetcher is enabled. The rest of the options are disabled.
• HPC —All options are enabled. This setting is also known as high performance computing.
• Custom —All performance profile options can be configured from the BIOS setup on the server. In addition, the Hardware Prefetcher and Adjacent Cache-Line Prefetch options can be configured in the fields below.
Whether the processor allows the Intel hardware prefetcher to fetch streams of data and instruction from memory into the unified second-level cache when necessary. This can be one of the following:
• Disabled —The hardware prefetcher is not used.
• Enabled —The processor uses the hardware prefetcher when cache issues are detected.
Whether the processor fetches cache lines in even/odd pairs instead of fetching just the required line. This can be one of the following:
• Disabled —The processor only fetches the required line.
• Enabled — The processor fetches both the required line and its paired line.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
399
BIOS Parameters by Server Model
BIOS Parameters by Server Model
Name
DCU Streamer Prefetch
DCU IP Prefetcher
Direct Cache Access Support
Power Technology
Description
Whether the processor uses the DCU IP Prefetch mechanism to analyze historical cache access patterns and preload the most relevant lines in the L1 cache. This can be one of the following:
• Disabled —The processor does not try to anticipate cache read requirements and only fetches explicitly requested lines.
• Enabled —The DCU prefetcher analyzes the cache read pattern and prefetches the next line in the cache if it determines that it may be needed.
Whether the processor uses the DCU IP Prefetch mechanism to analyze historical cache access patterns and preload the most relevant lines in the L1 cache. This can be one of the following:
• Disabled —The processor does not preload any cache data.
• Enabled —The DCU IP prefetcher preloads the L1 cache with the data it determines to be the most relevant.
Allows processors to increase I/O performance by placing data from I/O devices directly into the processor cache. This setting helps to reduce cache misses. This can be one of the following:
• Disabled —Data from I/O devices is not placed directly into the processor cache.
• Enabled —Data from I/O devices is placed directly into the processor cache.
Enables you to configure the CPU power management settings for the following options:
• Enhanced Intel Speedstep Technology
• Intel Turbo Boost Technology
• Processor Power State C6
Power Technology can be one of the following:
• Custom —The server uses the individual settings for the
BIOS parameters mentioned above. You must select this option if you want to change any of these BIOS parameters.
• Disabled —The server does not perform any CPU power management and any settings for the BIOS parameters mentioned above are ignored.
• Energy Efficient —The server determines the best settings for the BIOS parameters mentioned above and ignores the individual settings for these parameters.
400
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
BIOS Parameters by Server Model
BIOS Parameters by Server Model
Name
Enhanced Intel Speedstep Technology
Description
Whether the processor uses Enhanced Intel SpeedStep
Technology, which allows the system to dynamically adjust processor voltage and core frequency. This technology can result in decreased average power consumption and decreased average heat production. This can be one of the following:
• Disabled —The processor never dynamically adjusts its voltage or frequency.
• Enabled —The processor utilizes Enhanced Intel SpeedStep
Technology and enables all supported processor sleep states to further conserve power.
We recommend that you contact your operating system vendor to make sure the operating system supports this feature.
Note Power Technology must be set to Custom server ignores the setting for this parameter.
or the
Intel Turbo Boost Technology
Processor C3 Report
Whether the processor uses Intel Turbo Boost Technology, which allows the processor to automatically increase its frequency if it is running below power, temperature, or voltage specifications.
This can be one of the following:
• Disabled —The processor does not increase its frequency automatically.
• Enabled —The processor utilizes Turbo Boost Technology if required.
Note Power Technology must be set to Custom or the server ignores the setting for this parameter.
Whether the BIOS sends the C3 report to the operating system.
When the OS receives the report, it can transition the processor into the lower C3 power state to decrease energy usage while maintaining optimal processor performance. This can be one of the following:
• Disabled —BIOS does not send C3 report.
• Enabled —BIOS sends the C3 report, allowing the OS to transition the processor to the C3 low power state.
Note Power Technology must be set to Custom or the server ignores the setting for this parameter.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
401
BIOS Parameters by Server Model
BIOS Parameters by Server Model
Name
Processor C6 Report
Processor Power State C1 Enhanced
P-STATE Coordination
Description
Whether the BIOS sends the C6 report to the operating system.
When the OS receives the report, it can transition the processor into the lower C6 power state to decrease energy usage while maintaining optimal processor performance. This can be one of the following:
• Disabled —The BIOS does not send the C6 report.
• Enabled —The BIOS sends the C6 report, allowing the OS to transition the processor to the C6 low power state.
Note Power Technology must be set to Custom or the server ignores the setting for this parameter.
Whether the CPU transitions to its minimum frequency when entering the C1 state. This can be one of the following:
• Disabled —The CPU continues to run at its maximum frequency in C1 state.
• Enabled —The CPU transitions to its minimum frequency.
This option saves the maximum amount of power in C1 state.
Allows you to define how BIOS communicates the P-state support model to the operating system. There are 3 models as defined by the Advanced Configuration and Power Interface
(ACPI) specification.
• HW_ALL —The processor hardware is responsible for coordinating the P-state among logical processors with dependencies (all logical processors in a package).
• SW_ALL —The OS Power Manager (OSPM) is responsible for coordinating the P-state among logical processors with dependencies (all logical processors in a physical package), and must initiate the transition on all of the logical processors.
• SW_ANY —The OS Power Manager (OSPM) is responsible for coordinating the P-state among logical processors with dependencies (all logical processors in a package), and may initiate the transition on any of the logical processors in the domain.
Note Power Technology must be set to Custom or the server ignores the setting for this parameter.
402
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
BIOS Parameters by Server Model
BIOS Parameters by Server Model
Name
SINGLE_PCTL drop-down list
Config TDP drop-down list
Energy Performance Tuning
Energy Performance
Description
Facilitates single PCTL support for better processor power management. This can be one of the following:
• No
• Yes
Allows you to configure the Thermal Design Power (TDP) settings for the system. TDP is the maximum amount of power allowed for running applications without triggering an overheating event. This can be one of the following:
• Disabled —Disables the TDP settings. This is the default value.
• Enabled —Enables the TDP settings.
Allows you to choose BIOS or Operating System for energy performance bias tuning. This can be one of the following:
• OS — Chooses OS for energy performance tuning.
• BIOS — Chooses BIOS for energy performance tuning.
Allows you to determine whether system performance or energy efficiency is more important on this server. This can be one of the following:
• Balanced Energy
• Balanced Performance
• Energy Efficient
• Performance
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
403
BIOS Parameters by Server Model
Name
Package C State Limit
Extended APIC
Workload Configuration
BIOS Parameters by Server Model
Description
The amount of power available to the server components when they are idle. This can be one of the following:
• C0 state —The server provides all server components with full power at all times. This option maintains the highest level of performance and requires the greatest amount of power.
• C1 state —When the CPU is idle, the system slightly reduces the power consumption. This option requires less power than C0 and allows the server to return quickly to high performance mode.
• C3 state —When the CPU is idle, the system reduces the power consumption further than with the C1 option. This requires less power than C1 or C0, but it takes the server slightly longer to return to high performance mode.
• C6 state —When the CPU is idle, the system reduces the power consumption further than with the C3 option. This option saves more power than C0, C1, or C3, but there may be performance issues until the server returns to full power.
• C7 state —When the CPU is idle, the server makes a minimal amount of power available to the components.
This option saves the maximum amount of power but it also requires the longest time for the server to return to high performance mode.
• No Limit —The server may enter any available C state.
Allows you to enable or disable extended APIC support. This can be one of the following:
• XAPIC —Enables APIC support.
• X2APIC —Enables APIC and also enables Intel VT-d and
Interrupt Remapping .
Allows you to set a parameter to optimize workload characterization. This can be one of the following:
• Balanced — Chooses balanced option for optimization.
• I/O Sensitive — Chooses I/O sensitive option for optimization.
Note We recommend you to set the workload configuration to Balanced .
404
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
BIOS Parameters by Server Model
BIOS Parameters by Server Model
Name
IIO Error Enable drop-down list
Description
Allows you to generate the IIO-related errors. This can be one of the following:
• Yes
• No
Memory Configuration Parameters
Name
Select Memory RAS
DRAM Clock Throttling
Description
How the memory reliability, availability, and serviceability
(RAS) is configured for the server. This can be one of the following:
• Maximum Performance —System performance is optimized.
• Mirroring —System reliability is optimized by using half the system memory as backup.
• Lockstep —If the DIMM pairs in the server have an identical type, size, and organization and are populated across the SMI channels, you can enable lockstep mode to minimize memory access latency and provide better performance. This option offers better system performance than Mirroring and better reliability than Maximum
Performance but lower reliability than Mirroring and lower system performance than Maximum Performance.
Allows you to tune the system settings between the memory bandwidth and power consumption. This can be one of the following:
• Balanced — DRAM clock throttling is reduced, providing a balance between performance and power.
• Performance —DRAM clock throttling is disabled, providing increased memory bandwidth at the cost of additional power.
• Energy Efficient —DRAM clock throttling is increased to improve energy efficiency.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
405
BIOS Parameters by Server Model
BIOS Parameters by Server Model
Name
Low Voltage DDR Mode
Closed Loop Therm Throt drop-down list Allows for the support of Closed-Loop Thermal Throttling, which improves reliability and reduces CPU power consumption through the automatic voltage control while the CPUs are in the idle state. This can be one of the following:
• Disabled —Disables closed loop thermal throttling.
• Enabled —Enables closed loop thermal throttling. This is the default value.
Channel Interleaving
Description
Whether the system prioritizes low voltage or high frequency memory operations. This can be one of the following:
• Power Saving Mode —The system prioritizes low voltage memory operations over high frequency memory operations.
This mode may lower memory frequency in order to keep the voltage low.
• Performance Mode —The system prioritizes high frequency operations over low voltage operations.
Rank Interleaving
Whether the CPU divides memory blocks and spreads contiguous portions of data across interleaved channels to enable simultaneous read operations. This can be one of the following:
• Auto —The CPU determines what interleaving is done.
• 1 Way —Some channel interleaving is used.
• 2 Way
• 3 Way
• 4 Way —The maximum amount of channel interleaving is used.
Whether the CPU interleaves physical ranks of memory so that one rank can be accessed while another is being refreshed. This can be one of the following:
• Auto —The CPU determines what interleaving is done.
• 1 Way —Some rank interleaving is used.
• 2 Way
• 4 Way
• 8 Way —The maximum amount of rank interleaving is used.
406
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
BIOS Parameters by Server Model
BIOS Parameters by Server Model
Name
Patrol Scrub
Demand Scrub
Description
Whether the system actively searches for, and corrects, single bit memory errors even in unused portions of the memory on the server. This can be one of the following:
• Disabled —The system checks for memory ECC errors only when the CPU reads or writes a memory address.
• Enabled —The system periodically reads and writes memory searching for ECC errors. If any errors are found, the system attempts to fix them. This option may correct single bit errors before they become multi-bit errors, but it may adversely affect performance when the patrol scrub is running.
Whether the system corrects single bit memory errors encountered when the CPU or I/O makes a demand read. This can be one of the following:
• Disabled — Single bit memory errors are not corrected.
• Enabled — Single bit memory errors are corrected in memory and the corrected data is set in response to the demand read.
Altitude The approximate number of meters above sea level at which the physical server is installed. This can be one of the following:
• Auto —The CPU determines the physical elevation.
• 300 M —The server is approximately 300 meters above sea level.
• 900 M —The server is approximately 900 meters above sea level.
• 1500 M —The server is approximately 1500 meters above sea level.
• 3000 M —The server is approximately 3000 meters above sea level.
Panic and High Watermark drop-down list
When set to low, the memory controller does not postpone refreshes while Memory Refresh Rate is set to 1X Refresh .
This can be one of the following:
• Low —Refresh rate is set to low.
• High —Refresh rate is set to high.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
407
BIOS Parameters by Server Model
BIOS Parameters by Server Model
QPI Configuration Parameters
Name
QPI Link Frequency Select
QPI Snoop Mode
Description
The Intel QuickPath Interconnect (QPI) link frequency, in gigatransfers per second (GT/s). This can be one of the following:
• Auto —The CPU determines the QPI link frequency.
• 6.4 GT/s
• 7.2 GT/s
• 8.0 GT/s
The Intel QuickPath Interconnect (QPI) snoop mode. This can be one of the following:
• Disabled —Disables the QPI snoop mode.
• Cluster on Die —Enables Cluster On Die. When enabled LLC is split into two parts with an independent caching agent for each.
This helps increase the performance in some workloads. This mode is available only for processors that have 10 or more cores. It is the best mode for highly NUMA optimized workloads.
• Auto —The CPU automatically recognizes this as Early Snoop mode. This is the default value.
USB Configuration Parameters
Name
Legacy USB Support
Port 60/64 Emulation
Description
Whether the system supports legacy USB devices. This can be one of the following:
• Disabled —USB devices are only available to EFI applications.
• Enabled —Legacy USB support is always available.
• Auto —Disables legacy USB support if no USB devices are connected.
Whether the system supports 60h/64h emulation for complete USB keyboard legacy support. This can be one of the following:
• Disabled —60h/64 emulation is not supported.
• Enabled —60h/64 emulation is supported.
You should select this option if you are using a non-USB aware operating system on the server.
408
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
BIOS Parameters by Server Model
Name
All USB Devices
USB Port: Rear
USB Port: Internal
USB Port: KVM
USB Port: vMedia xHCI Mode
BIOS Parameters by Server Model
Description
Whether all physical and virtual USB devices are enabled or disabled.
This can be one of the following:
• Disabled —All USB devices are disabled.
• Enabled —All USB devices are enabled.
Whether the rear panel USB devices are enabled or disabled. This can be one of the following:
• Disabled —Disables the rear panel USB ports. Devices connected to these ports are not detected by the BIOS and operating system.
• Enabled —Enables the rear panel USB ports. Devices connected to these ports are detected by the BIOS and operating system.
Whether the internal USB devices are enabled or disabled. This can be one of the following:
• Disabled —Disables the internal USB ports. Devices connected to these ports are not detected by the BIOS and operating system.
• Enabled —Enables the internal USB ports. Devices connected to these ports are detected by the BIOS and operating system.
Whether the vKVM ports are enabled or disabled. This can be one of the following:
• Disabled —Disables the vKVM keyboard and/or mouse devices.
Keyboard and/or mouse will not work in the vKVM window.
• Enabled —Enables the vKVM keyboard and/or mouse devices.
Whether the virtual media devices are enabled or disabled. This can be one of the following:
• Disabled —Disables the vMedia devices.
• Enabled —Enables the vMedia devices.
Whether the xHCI controller legacy support is enabled or disabled. This can be one of the following:
• Disabled —Disables the xHCI controller legacy support.
• Enabled —Enables the xHCI controller legacy support.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
409
BIOS Parameters by Server Model
BIOS Parameters by Server Model
PCI Configuration Parameters
Name
Memory Mapped I/O Above 4GB
SR-IOV Support drop-down list
Description
Whether to enable or disable MMIO above 4GB or not. This can be one of the following:
• Disabled —The server does not map I/O of 64-bit PCI devices to 4GB or greater address space.
• Enabled —The server maps I/O of 64-bit PCI devices to
4GB or greater address space.
Note PCI devices that are 64-bit compliant but use a legacy option ROM may not function correctly with this setting enabled.
Whether SR-IOV (Single Root I/O Virtualization) is enabled or disabled on the server. This can be one of the following:
• Disabled —SR-IOV is disabled.
• Enabled —SR-IOV is enabled.
Serial Configuration Parameters
Name
Out-of-Band Mgmt Port
Description
Allows you to configure the COM port 0 that can be used for Windows
Emergency Management services. ACPI SPCR table is reported based on this setup option. This can be one of the following:
• Disabled —Configures the COM port 0 as a general purpose port for use with the Windows Operating System.
• Enabled —Configures the COM port 0 as a remote management port for Windows Emergency Management services.
Console Redirection Allows a serial port to be used for console redirection during POST and
BIOS booting. After the BIOS has booted and the operating system is responsible for the server, console redirection is irrelevant and has no effect. This can be one of the following:
• Disabled —No console redirection occurs during POST.
• COM 0 —Enables console redirection on COM port 0 during POST.
• COM 1 —Enables console redirection on COM port 1 during POST.
410
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
BIOS Parameters by Server Model
Name
Terminal Type
Bits per second
Flow Control
BIOS Parameters by Server Model
Description
What type of character formatting is used for console redirection. This can be one of the following:
• PC-ANSI —The PC-ANSI terminal font is used.
• VT100 —A supported vt100 video terminal and its character set are used.
• VT100+ —A supported vt100-plus video terminal and its character set are used.
• VT-UTF8 —A video terminal with the UTF-8 character set is used.
Note This setting must match the setting on the remote terminal application.
What BAUD rate is used for the serial port transmission speed. If you disable Console Redirection, this option is not available. This can be one of the following:
• 9600 —A 9,600 BAUD rate is used.
• 19200 —A 19,200 BAUD rate is used.
• 38400 —A 38,400 BAUD rate is used.
• 57600 —A 57,600 BAUD rate is used.
• 115200 —A 115,200 BAUD rate is used.
Note This setting must match the setting on the remote terminal application.
Whether a handshake protocol is used for flow control. Request to Send
/ Clear to Send (RTS/CTS) helps to reduce frame collisions that can be introduced by a hidden terminal problem. This can be one of the following:
• None —No flow control is used.
• Hardware RTS/CTS —RTS/CTS is used for flow control.
Note This setting must match the setting on the remote terminal application.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
411
BIOS Parameters by Server Model
BIOS Parameters by Server Model
Name
Putty KeyPad
Description
Allows you to change the action of the PuTTY function keys and the top row of the numeric keypad. This can be one of the following:
• VT100 —The function keys generate ESC OP through ESC O[.
• LINUX —Mimics the Linux virtual console. Function keys F6 to
F12 behave like the default mode, but F1 to F5 generate ESC [[A through ESC [[E .
• XTERMR6 —Function keys F5 to F12 behave like the default mode. Function keys F1 to F4 generate ESC OP through ESC OS, which are the sequences produced by the top row of the keypad on
Digital terminals.
• SCO —The function keys F1 to F12 generate ESC [M through
ESC [X . The function and shift keys generate ESC [Y through
ESC [j . The control and function keys generate ESC [k through
ESC [v . The shift, control and function keys generate ESC [w through ESC [{ .
• ESCN —The default mode. The function keys match the general behavior of Digital terminals. The function keys generate sequences such as ESC [11~ and ESC [12~ .
• VT400 —The function keys behave like the default mode. The top row of the numeric keypad generates ESC OP through ESC OS .
Redirection After BIOS POST Whether BIOS console redirection should be active after BIOS POST is complete and control given to the OS bootloader. This can be one of the following:
• Always Enable —BIOS Legacy console redirection is active during the OS boot and run time.
• Bootloader —BIOS Legacy console redirection is disabled before giving control to the OS boot loader.
LOM and PCIe Slots Configuration Parameters
Name
CDN Support for VIC
Description
Whether the Ethernet Network naming convention is according to
Consistent Device Naming (CDN) or the traditional way of naming conventions. This can be one of the following:
• Disabled — CDN support for VIC cards is disabled.
• Enabled — CDN support is enabled for VIC cards.
Note CDN support for VIC cards work with Windows 2012 or the latest OS only.
412
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
BIOS Parameters by Server Model
BIOS Parameters by Server Model
Name
PCI ROM CLP
PCH SATA Mode
All Onboard LOM Ports
LOM Port n OptionROM
All PCIe Slots OptionROM
Description
PCI ROM Command Line Protocol (CLP) controls the execution of different Option ROMs such as PxE and iSCSI that are present in the card. By default, it is disabled.
• Enabled — Enables you to configure execution of different option
ROMs such as PxE and iSCSI for an individual ports separately.
• Disabled —The default option. You cannot choose different option
ROMs. A default option ROM is executed during PCI enumeration.
This options allows you to select the PCH SATA mode. This can be one of the following:
• AHCI —Sets both SATA and sSATA controllers to AHCI mode.
• Disabled —Disables both SATA and sSATA controllers.
• LSI SW Raid — Sets both SATA and sSATA controllers to raid mode for LSI SW Raid
Whether all LOM ports are enabled or disabled. This can be one of the following:
• Disabled —All LOM ports are disabled.
• Enabled —All LOM ports are enabled.
Whether Option ROM is available on the LOM port designated by n .
This can be one of the following:
• Disabled —The Option ROM for slot n is not available.
• Enabled —The Option ROM for slot n is available.
• UEFI Only —The Option ROM for slot n is available for UEFI only.
• Legacy Only —The Option ROM for slot n is available for legacy only.
Whether the server can use Option ROM present in the PCIe Cards.
This can be one of the following:
• Disabled —The Option ROM for slot n is not available.
• Enabled —The Option ROM for slot n is available.
• UEFI Only —The Option ROM for slot n is available for UEFI only.
• Legacy Only —The Option ROM for slot n is available for legacy only.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
413
BIOS Parameters by Server Model
BIOS Parameters by Server Model
Name
PCIe Slot:n OptionROM
Description
Whether the server can use the Option ROMs present in the PCIe Cards.
This can be one of the following:
• Disabled —The Option ROM for slot n is not available.
• Enabled —The Option ROM for slot n is available.
• UEFI Only —The Option ROM for slot n is available for UEFI only.
• Legacy Only —The Option ROM for slot n is available for legacy only.
PCIe Slot:MLOM OptionROM This options allows you to control the Option ROM execution of the
PCIe adapter connected to the MLOM slot. This can be one of the following:
• Enabled —Executes both legacy and UEFI Option ROM.
• Disabled —Both legacy and UEFI Option ROM will not be executed.
• UEFI Only —Executes only UEFI Option ROM.
• Legacy Only —Executes only Legacy Option ROM.
PCIe Slot:HBA OptionROM This options allows you to control the Option ROM execution of the
PCIe adapter connected to the HBA slot. This can be one of the following:
• Enabled —Executes both legacy and UEFI Option ROM.
• Disabled —Both legacy and UEFI Option ROM will not be executed.
• UEFI Only —Executes only UEFI Option ROM.
• Legacy Only —Executes only Legacy Option ROM.
PCIe Slot:N1 OptionROM This options allows you to control the Option ROM execution of the
PCIe adapter connected to the SSD:NVMe1 slot. This can be one of the following:
• Enabled —Executes both legacy and UEFI Option ROM.
• Disabled —Both legacy and UEFI Option ROM will not be executed.
• UEFI Only —Executes only UEFI Option ROM.
• Legacy Only —Executes only Legacy Option ROM.
414
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
BIOS Parameters by Server Model
BIOS Parameters by Server Model
Name
PCIe Slot:N2 OptionROM
PCIe Slot:N2 OptionROM
PCIe Slot:HBA Link Speed
PCIe SlotHBALinkSpeed
Description
This options allows you to control the Option ROM execution of the
PCIe adapter connected to the SSD:NVMe2 slot. This can be one of the following:
• Enabled —Executes both legacy and UEFI Option ROM.
• Disabled —Both legacy and UEFI Option ROM will not be executed.
• UEFI Only —Executes only UEFI Option ROM.
• Legacy Only —Executes only Legacy Option ROM.
This options allows you to control the Option ROM execution of the
PCIe adapter connected to the SSD:NVMe2 slot. This can be one of the following:
• Enabled —Executes both legacy and UEFI Option ROM.
• Disabled —Both legacy and UEFI Option ROM will not be executed.
• UEFI Only —Executes only UEFI Option ROM.
• Legacy Only —Executes only Legacy Option ROM.
This option allows you to restrict the maximum speed of an adapter card installed in PCIe HBA slot. This can be one of the following:
• Auto — System selects the maximum speed allowed.
• GEN1 —2.5GT/s (gigatransfers per second) is the maximum speed allowed.
• GEN2 —5GT/s is the maximum speed allowed.
• GEN3 —8GT/s is the maximum speed allowed.
• Disabled —The maximum speed is not restricted.
BIOS Configuration Dialog Box Button Bar
Important The buttons in this dialog box affect all BIOS parameters on all available tabs, not just the parameters on the tab that you are viewing.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
415
BIOS Parameters by Server Model
Server Management Tab for C460 M4 Servers
Name
Save Changes button
Reset Values button
Restore Defaults button
Cancel button
Description
Saves the settings for the BIOS parameters on all three tabs and closes the dialog box.
If the Reboot Host Immediately check box is checked, the server is rebooted immediately and the new BIOS settings go into effect.
Otherwise the changes are saved until the server is manually rebooted.
Restores the values for the BIOS parameters on all three tabs to the settings that were in effect when this dialog box was first opened.
Sets the BIOS parameters on all three tabs to their default settings.
Closes the dialog box without making any changes.
Server Management Tab for C460 M4 Servers
Reboot Server Option
If you want your changes applied automatically after you click Save Changes , check the Reboot Host
Immediately check box. Cisco IMC immediately reboots the server and applies your changes.
If you want to apply your changes at a later time, clear the Reboot Host Immediately check box. Cisco IMC stores the changes and applies them the next time the server reboots.
Note If there are existing BIOS parameter changes pending, Cisco IMC automatically overwrites the stored values with the current settings when you click Save Changes .
Server Management BIOS Parameters
Name
FRB-2 Timer
Description
Whether the FRB2 timer is used by Cisco IMC to recover the system if it hangs during POST. This can be one of the following:
• Disabled —The FRB2 timer is not used.
• Enabled —The FRB2 timer is started during POST and used to recover the system if necessary.
416
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
BIOS Parameters by Server Model
BIOS Parameters by Server Model
Name
OS Watchdog Timer
OS Watchdog Timer Timeout
OS Watchdog Timer Policy
Description
Whether the BIOS programs the watchdog timer with a specified timeout value. This can be one of the following:
• Disabled —The watchdog timer is not used to track how long the server takes to boot.
• Enabled —The watchdog timer tracks how long the server takes to boot. If the server does not boot within the length of time specified in the OS Boot Watchdog Timer
Timeout field, the Cisco IMC logs an error and takes the action specified in the OS Boot Watchdog Policy field.
If OS does not boot within the specified time, OS watchdog timer expires and system takes action according to timer policy.
This can be one of the following:
• 5 Minutes —The OS watchdog timer expires 5 minutes after it begins to boot.
• 10 Minutes —The OS watchdog timer expires 10 minutes after it begins to boot.
• 15 Minutes —The OS watchdog timer expires 15 minutes after it begins to boot.
• 20 Minutes —The OS watchdog timer expires 20 minutes after it begins to boot.
Note This option is only applicable if you enable the OS
Boot Watchdog Timer.
What action the system takes if the watchdog timer expires. This can be one of the following:
• Do Nothing —The server takes no action if the watchdog timer expires during OS boot.
• Power Down —The server is powered off if the watchdog timer expires during OS boot.
• Reset —The server is reset if the watchdog timer expires during OS boot.
Note This option is only applicable if you enable the OS
Boot Watchdog Timer.
BIOS Configuration Dialog Box Button Bar
Important The buttons in this dialog box affect all BIOS parameters on all available tabs, not just the parameters on the tab that you are viewing.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
417
BIOS Parameters by Server Model
C220 M4 and C240 M4 Servers
Name
Save Changes button
Reset Values button
Restore Defaults button
Cancel button
Description
Saves the settings for the BIOS parameters on all three tabs and closes the dialog box.
If the Reboot Host Immediately check box is checked, the server is rebooted immediately and the new BIOS settings go into effect.
Otherwise the changes are saved until the server is manually rebooted.
Restores the values for the BIOS parameters on all three tabs to the settings that were in effect when this dialog box was first opened.
Sets the BIOS parameters on all three tabs to their default settings.
Closes the dialog box without making any changes.
C220 M4 and C240 M4 Servers
Main Tab for C220M4 and C240M4 Servers
Main BIOS Parameters
Name
Reboot Host Immediately checkbox
TPM Support
Power ON Password Support drop-down
Description
Upon checking, reboots the host server immediately. You must check the checkbox after saving changes.
TPM (Trusted Platform Module) is a microchip designed to provide basic security-related functions primarily involving encryption keys.
This option allows you to control the TPM Security Device support for the system. It can be one of the following:
• Disabled —The server does not use the TPM.
• Enabled —The server uses the TPM.
Note We recommend that you contact your operating system vendor to make sure the operating system supports this feature.
This token requires that you set a BIOS password before using the F2
BIOS configuration. If enabled, password needs to be validated before you access BIOS functions such as IO configuration, BIOS set up, and booting to an operating system using BIOS. It can be one of the following:
• Disabled —Support is disabled.
• Enabled —Support is enabled.
418
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
BIOS Parameters by Server Model
Advanced Tab for C220M4 and C240M4 Servers
Actions Area
Name
Save button
Reset button
Restore Defaults button
Description
Saves the settings for the BIOS parameters and closes the dialog box.
If the Reboot Host Immediately check box is checked, the server is rebooted immediately and the new BIOS settings go into effect.
Otherwise the changes are saved until the server is manually rebooted.
Resets the values for the BIOS parameters on all three tabs to the settings that were in effect when this dialog box was first opened.
Sets the BIOS parameters on all three tabs to their default settings.
Advanced Tab for C220M4 and C240M4 Servers
Reboot Server Option
If you want your changes applied automatically after you click Save Changes , check the Reboot Host
Immediately check box. Cisco IMC immediately reboots the server and applies your changes.
If you want to apply your changes at a later time, clear the Reboot Host Immediately check box. Cisco IMC stores the changes and applies them the next time the server reboots.
Note If there are existing BIOS parameter changes pending, Cisco IMC automatically overwrites the stored values with the current settings when you click Save Changes .
Processor Configuration Parameters
Name
Intel Hyper-Threading Technology
Description
Whether the processor uses Intel Hyper-Threading Technology, which allows multithreaded software applications to execute threads in parallel within each processor. This can be one of the following:
• Disabled —The processor does not permit hyperthreading.
• Enabled —The processor allows for the parallel execution of multiple threads.
We recommend that you contact your operating system vendor to make sure the operating system supports this feature.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
419
BIOS Parameters by Server Model
Name
Number of Enabled Cores
Execute Disable
Intel VT
Intel VT-d
BIOS Parameters by Server Model
Description
Allows you to disable one or more of the physical cores on the server. This can be one of the following:
• All —Enables all physical cores. This also enables Hyper
Threading on the associated logical processor cores.
• 1 through n —Specifies the number of physical processor cores that can run on the server. Each physical core has an associated logical core.
We recommend that you contact your operating system vendor to make sure the operating system supports this feature.
Classifies memory areas on the server to specify where application code can execute. As a result of this classification, the processor disables code execution if a malicious worm attempts to insert code in the buffer. This setting helps to prevent damage, worm propagation, and certain classes of malicious buffer overflow attacks. This can be one of the following:
• Disabled —The processor does not classify memory areas.
• Enabled —The processor classifies memory areas.
We recommend that you contact your operating system vendor to make sure the operating system supports this feature.
Whether the processor uses Intel Virtualization Technology
(VT), which allows a platform to run multiple operating systems and applications in independent partitions. This can be one of the following:
• Disabled —The processor does not permit virtualization.
• Enabled —The processor allows multiple operating systems in independent partitions.
Note If you change this option, you must power cycle the server before the setting takes effect.
Whether the processor uses Intel Virtualization Technology for
Directed I/O (VT-d). This can be one of the following:
• Disabled —The processor does not use virtualization technology.
• Enabled —The processor uses virtualization technology.
420
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
BIOS Parameters by Server Model
BIOS Parameters by Server Model
Name
Intel VT-d Interrupt Remapping
Intel VT-d PassThrough DMA
Intel VT-d Coherency Support
Intel VT-d ATS Support
Description
Whether the processor supports Intel VT-d Interrupt Remapping.
This can be one of the following:
• Disabled —The processor does not support remapping.
• Enabled —The processor uses VT-d Interrupt Remapping as required.
Whether the processor supports Intel VT-d Pass-through DMA.
This can be one of the following:
• Disabled —The processor does not support pass-through
DMA.
• Enabled —The processor uses VT-d Pass-through DMA as required.
Whether the processor supports Intel VT-d Coherency. This can be one of the following:
• Disabled —The processor does not support coherency.
• Enabled —The processor uses VT-d Coherency as required.
Whether the processor supports Intel VT-d Address Translation
Services (ATS). This can be one of the following:
• Disabled —The processor does not support ATS.
• Enabled —The processor uses VT-d ATS as required.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
421
BIOS Parameters by Server Model
BIOS Parameters by Server Model
Name
CPU Performance
Hardware Prefetcher
Adjacent Cache Line Prefetcher
Description
Sets the CPU performance profile for the server. The performance profile consists of the following options:
• DCU Streamer Prefetcher
• DCU IP Prefetcher
• Hardware Prefetcher
• Adjacent Cache-Line Prefetch
This can be one of the following:
• Enterprise —All options are enabled.
• High Throughput —Only the DCU IP Prefetcher is enabled. The rest of the options are disabled.
• HPC —All options are enabled. This setting is also known as high performance computing.
• Custom —All performance profile options can be configured from the BIOS setup on the server. In addition, the Hardware Prefetcher and Adjacent Cache-Line Prefetch options can be configured in the fields below.
Whether the processor allows the Intel hardware prefetcher to fetch streams of data and instruction from memory into the unified second-level cache when necessary. This can be one of the following:
• Disabled —The hardware prefetcher is not used.
• Enabled —The processor uses the hardware prefetcher when cache issues are detected.
Whether the processor fetches cache lines in even/odd pairs instead of fetching just the required line. This can be one of the following:
• Disabled —The processor only fetches the required line.
• Enabled — The processor fetches both the required line and its paired line.
422
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
BIOS Parameters by Server Model
Name
DCU Streamer Prefetch
DCU IP Prefetcher
Direct Cache Access Support
Power Technology
BIOS Parameters by Server Model
Description
Whether the processor uses the DCU IP Prefetch mechanism to analyze historical cache access patterns and preload the most relevant lines in the L1 cache. This can be one of the following:
• Disabled —The processor does not try to anticipate cache read requirements and only fetches explicitly requested lines.
• Enabled —The DCU prefetcher analyzes the cache read pattern and prefetches the next line in the cache if it determines that it may be needed.
Whether the processor uses the DCU IP Prefetch mechanism to analyze historical cache access patterns and preload the most relevant lines in the L1 cache. This can be one of the following:
• Disabled —The processor does not preload any cache data.
• Enabled —The DCU IP prefetcher preloads the L1 cache with the data it determines to be the most relevant.
Allows processors to increase I/O performance by placing data from I/O devices directly into the processor cache. This setting helps to reduce cache misses. This can be one of the following:
• Disabled —Data from I/O devices is not placed directly into the processor cache.
• Enabled —Data from I/O devices is placed directly into the processor cache.
Enables you to configure the CPU power management settings for the following options:
• Enhanced Intel Speedstep Technology
• Intel Turbo Boost Technology
• Processor Power State C6
Power Technology can be one of the following:
• Custom —The server uses the individual settings for the
BIOS parameters mentioned above. You must select this option if you want to change any of these BIOS parameters.
• Disabled —The server does not perform any CPU power management and any settings for the BIOS parameters mentioned above are ignored.
• Energy Efficient —The server determines the best settings for the BIOS parameters mentioned above and ignores the individual settings for these parameters.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
423
BIOS Parameters by Server Model
BIOS Parameters by Server Model
Name
Enhanced Intel Speedstep Technology
Description
Whether the processor uses Enhanced Intel SpeedStep
Technology, which allows the system to dynamically adjust processor voltage and core frequency. This technology can result in decreased average power consumption and decreased average heat production. This can be one of the following:
• Disabled —The processor never dynamically adjusts its voltage or frequency.
• Enabled —The processor utilizes Enhanced Intel SpeedStep
Technology and enables all supported processor sleep states to further conserve power.
We recommend that you contact your operating system vendor to make sure the operating system supports this feature.
Note Power Technology must be set to Custom server ignores the setting for this parameter.
or the
Intel Turbo Boost Technology
Processor C3 Report
Whether the processor uses Intel Turbo Boost Technology, which allows the processor to automatically increase its frequency if it is running below power, temperature, or voltage specifications.
This can be one of the following:
• Disabled —The processor does not increase its frequency automatically.
• Enabled —The processor utilizes Turbo Boost Technology if required.
Note Power Technology must be set to Custom or the server ignores the setting for this parameter.
Whether the BIOS sends the C3 report to the operating system.
When the OS receives the report, it can transition the processor into the lower C3 power state to decrease energy usage while maintaining optimal processor performance. This can be one of the following:
• Disabled —BIOS does not send C3 report.
• Enabled —BIOS sends the C3 report, allowing the OS to transition the processor to the C3 low power state.
Note Power Technology must be set to Custom or the server ignores the setting for this parameter.
424
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
BIOS Parameters by Server Model
BIOS Parameters by Server Model
Name
Processor C6 Report
Processor Power State C1 Enhanced
P-STATE Coordination
Description
Whether the BIOS sends the C6 report to the operating system.
When the OS receives the report, it can transition the processor into the lower C6 power state to decrease energy usage while maintaining optimal processor performance. This can be one of the following:
• Disabled —The BIOS does not send the C6 report.
• Enabled —The BIOS sends the C6 report, allowing the OS to transition the processor to the C6 low power state.
Note Power Technology must be set to Custom or the server ignores the setting for this parameter.
Whether the CPU transitions to its minimum frequency when entering the C1 state. This can be one of the following:
• Disabled —The CPU continues to run at its maximum frequency in C1 state.
• Enabled —The CPU transitions to its minimum frequency.
This option saves the maximum amount of power in C1 state.
Allows you to define how BIOS communicates the P-state support model to the operating system. There are 3 models as defined by the Advanced Configuration and Power Interface
(ACPI) specification.
• HW_ALL —The processor hardware is responsible for coordinating the P-state among logical processors with dependencies (all logical processors in a package).
• SW_ALL —The OS Power Manager (OSPM) is responsible for coordinating the P-state among logical processors with dependencies (all logical processors in a physical package), and must initiate the transition on all of the logical processors.
• SW_ANY —The OS Power Manager (OSPM) is responsible for coordinating the P-state among logical processors with dependencies (all logical processors in a package), and may initiate the transition on any of the logical processors in the domain.
Note Power Technology must be set to Custom or the server ignores the setting for this parameter.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
425
BIOS Parameters by Server Model
BIOS Parameters by Server Model
Name
Boot Performance Mode drop-down list
Description
Allows the user to select the BIOS performance state that is set before the operating system handoff. This can be one of the following:
• Max Performance —Processor P-state ratio is maximum
• Max Efficient — Processor P-state ratio is minimum
Energy Performance Tuning Allows you to choose BIOS or Operating System for energy performance bias tuning. This can be one of the following:
• OS — Chooses OS for energy performance tuning.
• BIOS — Chooses BIOS for energy performance tuning.
Energy Performance Allows you to determine whether system performance or energy efficiency is more important on this server. This can be one of the following:
• Balanced Energy
• Balanced Performance
• Energy Efficient
• Performance
426
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
BIOS Parameters by Server Model
Name
Package C State Limit
Extended APIC
Workload Configuration
BIOS Parameters by Server Model
Description
The amount of power available to the server components when they are idle. This can be one of the following:
• C0 state —The server provides all server components with full power at all times. This option maintains the highest level of performance and requires the greatest amount of power.
• C1 state —When the CPU is idle, the system slightly reduces the power consumption. This option requires less power than C0 and allows the server to return quickly to high performance mode.
• C3 state —When the CPU is idle, the system reduces the power consumption further than with the C1 option. This requires less power than C1 or C0, but it takes the server slightly longer to return to high performance mode.
• C6 state —When the CPU is idle, the system reduces the power consumption further than with the C3 option. This option saves more power than C0, C1, or C3, but there may be performance issues until the server returns to full power.
• C7 state —When the CPU is idle, the server makes a minimal amount of power available to the components.
This option saves the maximum amount of power but it also requires the longest time for the server to return to high performance mode.
• No Limit —The server may enter any available C state.
Allows you to enable or disable extended APIC support. This can be one of the following:
• XAPIC —Enables APIC support.
• X2APIC —Enables APIC and also enables Intel VT-d and
Interrupt Remapping .
Allows you to set a parameter to optimize workload characterization. This can be one of the following:
• Balanced — Chooses balanced option for optimization.
• I/O Sensitive — Chooses I/O sensitive option for optimization.
Note We recommend you to set the workload configuration to Balanced .
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
427
BIOS Parameters by Server Model
BIOS Parameters by Server Model
Name
CPU HWPM drop-down list
Description
Enables the Hardware Power Management (HWPM) interface for better CPU performance and energy efficiency. This can be one of the following:
• Disabled —The P-States are controlled the same way as on predecessor processor generations.
• Native Mode —HWPM works with the operating system through a software interface.
• OOB Mode —The CPU autonomously controls its frequency based on the operating system energy efficiency.
CPU Autonomous Cstate drop-down list Enables CPU Autonomous C-State, which converts the HALT instructions to the MWAIT instructions. This can be one of the following:
• Disabled —CPU Autonomous C-state is disabled. This is the default value.
• Enabled —CPU Autonomous C-state is enabled.
Processor CMCI drop-down list Allows the CPU to trigger interrupts on corrected machine check events. The corrected machine check interrupt (CMCI) allows faster reaction than the traditional polling timer. This can be one of the following:
• Disabled —Disables CMCI.
• Enabled —Enables CMCI. This is the default value.
Memory Configuration Parameters
Name
Select Memory RAS
Description
How the memory reliability, availability, and serviceability
(RAS) is configured for the server. This can be one of the following:
• Maximum Performance —System performance is optimized.
• Mirroring —System reliability is optimized by using half the system memory as backup.
• Lockstep —If the DIMM pairs in the server have an identical type, size, and organization and are populated across the SMI channels, you can enable lockstep mode to minimize memory access latency and provide better performance. This option offers better system performance than Mirroring and better reliability than Maximum
Performance but lower reliability than Mirroring and lower system performance than Maximum Performance.
428
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
BIOS Parameters by Server Model
Name
NUMA
Channel Interleaving
Rank Interleaving
Patrol Scrub
BIOS Parameters by Server Model
Description
Whether the BIOS supports Non-Uniform Memory Access
(NUMA). This can be one of the following:
• Disabled —The BIOS does not support NUMA.
• Enabled —The BIOS includes the ACPI tables that are required for NUMA-aware operating systems. If you enable this option, the system must disable Inter-Socket Memory interleaving on some platforms.
Whether the CPU divides memory blocks and spreads contiguous portions of data across interleaved channels to enable simultaneous read operations. This can be one of the following:
• Auto —The CPU determines what interleaving is done.
• 1 Way —Some channel interleaving is used.
• 2 Way
• 3 Way
• 4 Way —The maximum amount of channel interleaving is used.
Whether the CPU interleaves physical ranks of memory so that one rank can be accessed while another is being refreshed. This can be one of the following:
• Auto —The CPU determines what interleaving is done.
• 1 Way —Some rank interleaving is used.
• 2 Way
• 4 Way
• 8 Way —The maximum amount of rank interleaving is used.
Whether the system actively searches for, and corrects, single bit memory errors even in unused portions of the memory on the server. This can be one of the following:
• Disabled —The system checks for memory ECC errors only when the CPU reads or writes a memory address.
• Enabled —The system periodically reads and writes memory searching for ECC errors. If any errors are found, the system attempts to fix them. This option may correct single bit errors before they become multi-bit errors, but it may adversely affect performance when the patrol scrub is running.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
429
BIOS Parameters by Server Model
BIOS Parameters by Server Model
Name
Demand Scrub
Altitude
Description
Whether the system corrects single bit memory errors encountered when the CPU or I/O makes a demand read. This can be one of the following:
• Disabled — Single bit memory errors are not corrected.
• Enabled — Single bit memory errors are corrected in memory and the corrected data is set in response to the demand read.
The approximate number of meters above sea level at which the physical server is installed. This can be one of the following:
• Auto —The CPU determines the physical elevation.
• 300 M —The server is approximately 300 meters above sea level.
• 900 M —The server is approximately 900 meters above sea level.
• 1500 M —The server is approximately 1500 meters above sea level.
• 3000 M —The server is approximately 3000 meters above sea level.
Panic and High Watermark drop-down list
When set to low, the memory controller does not postpone refreshes while Memory Refresh Rate is set to 1X Refresh .
This can be one of the following:
• Low —Refresh rate is set to low.
• High —Refresh rate is set to high.
QPI Configuration Parameters
Name
QPI Link Frequency Select
Description
The Intel QuickPath Interconnect (QPI) link frequency, in gigatransfers per second (GT/s). This can be one of the following:
• Auto —The CPU determines the QPI link frequency.
• 6.4 GT/s
• 7.2 GT/s
• 8.0 GT/s
430
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
BIOS Parameters by Server Model
BIOS Parameters by Server Model
Name
QPI Snoop Mode
Description
The Intel QuickPath Interconnect (QPI) snoop mode. This can be one of the following:
• Auto —The CPU automatically recognizes this as Early Snoop mode.
• Early Snoop —The distributed cache ring stops can send a snoop probe or a request to another caching agent directly. This mode has lower latency and it is best for workloads that have shared data sets across threads and can benefit from a cache-to-cache transfer, or for workloads that are not NUMA optimized.
• Home Snoop —The snoop is always spawned by the home agent
(centralized ring stop) for the memory controller. This mode has a higher local latency than early snoop, but it provides extra resources for a larger number of outstanding transactions.
• Home Directory Snoop — The home directory is an optional enabled feature that is implemented at both the HA and iMC logic in the processor. The goal of the directory is to filter snoops to the remote sockets and a node controller in scalable platforms and 2S and 4S configurations.
• Home Directory Snoop with OSB — In the Opportunistic Snoop
Broadcast (OSB) directory mode, the HA could choose to do speculative home snoop broadcast under very lightly loaded conditions even before the directory information has been collected and checked.
• Cluster on Die —Enables Cluster On Die. When enabled LLC is split into two parts with an independent caching agent for each.
This helps increase the performance in some workloads. This mode is available only for processors that have 10 or more cores. It is the best mode for highly NUMA optimized workloads.
USB Configuration Parameters
Name
Legacy USB Support
Description
Whether the system supports legacy USB devices. This can be one of the following:
• Disabled —USB devices are only available to EFI applications.
• Enabled —Legacy USB support is always available.
• Auto —Disables legacy USB support if no USB devices are connected.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
431
BIOS Parameters by Server Model
BIOS Parameters by Server Model
Name
Port 60/64 Emulation xHCI Mode
Description
Whether the system supports 60h/64h emulation for complete USB keyboard legacy support. This can be one of the following:
• Disabled —60h/64 emulation is not supported.
• Enabled —60h/64 emulation is supported.
You should select this option if you are using a non-USB aware operating system on the server.
Whether the xHCI controller legacy support is enabled or disabled. This can be one of the following:
• Disabled —Disables the xHCI controller legacy support.
• Enabled —Enables the xHCI controller legacy support.
xHCI Legacy Support drop-down list
Whether the system supports legacy xHCI controller. This can be one of the following:
• Disabled —Disables xHCI legacy support.
• Enabled —Enables xHCI legacy support. This is the default value.
All USB Devices
USB Port: Rear
USB Port: Front
Whether all physical and virtual USB devices are enabled or disabled.
This can be one of the following:
• Disabled —All USB devices are disabled.
• Enabled —All USB devices are enabled.
Whether the rear panel USB devices are enabled or disabled. This can be one of the following:
• Disabled —Disables the rear panel USB ports. Devices connected to these ports are not detected by the BIOS and operating system.
• Enabled —Enables the rear panel USB ports. Devices connected to these ports are detected by the BIOS and operating system.
Whether the front panel USB devices are enabled or disabled. This can be one of the following:
• Disabled —Disables the front panel USB ports. Devices connected to these ports are not detected by the BIOS and operating system
• Enabled —Enables the front panel USB ports. Devices connected to these ports are detected by the BIOS and operating system.
432
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
BIOS Parameters by Server Model
BIOS Parameters by Server Model
Name
USB Port: Internal
USB Port: KVM
USB Port: vMedia
PCI Configuration Parameters
Name
Memory Mapped I/O Above 4GB
Description
Whether the internal USB devices are enabled or disabled. This can be one of the following:
• Disabled —Disables the internal USB ports. Devices connected to these ports are not detected by the BIOS and operating system.
• Enabled —Enables the internal USB ports. Devices connected to these ports are detected by the BIOS and operating system.
Whether the vKVM ports are enabled or disabled. This can be one of the following:
• Disabled —Disables the vKVM keyboard and/or mouse devices.
Keyboard and/or mouse will not work in the vKVM window.
• Enabled —Enables the vKVM keyboard and/or mouse devices.
Whether the virtual media devices are enabled or disabled. This can be one of the following:
• Disabled —Disables the vMedia devices.
• Enabled —Enables the vMedia devices.
Sriov
Description
Whether to enable or disable MMIO above 4GB or not. This can be one of the following:
• Disabled —The server does not map I/O of 64-bit PCI devices to 4GB or greater address space.
• Enabled —The server maps I/O of 64-bit PCI devices to
4GB or greater address space.
Note PCI devices that are 64-bit compliant but use a legacy option ROM may not function correctly with this setting enabled.
Whether SR-IOV (Single Root I/O Virtualization) is enabled or disabled on the server. This can be one of the following:
• Disabled —SR-IOV is disabled.
• Enabled —SR-IOV is enabled.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
433
BIOS Parameters by Server Model
BIOS Parameters by Server Model
Name
ASPM Support drop-down list
Description
Allows you to set the level of ASPM (Active Power State
Management) support in the BIOS. This can be one of the following:
• Disabled —ASPM support is disabled in the BIOS.
• Force L0s —Force all links to L0 standby (L0s) state.
• Auto —The CPU determines the power state
NVMe SSD Hot-Plug Support drop-down list
Allows you to replace an NVMe SSD without powering down the server. This can be one of the following:
• Disabled —NVMe SSD hot-plug support is disabled. This is the default value.
• Enabled —NVMe SSD hot-plug support is enabled.
VGA Priority drop-down list Allows you to set the priority for VGA graphics devices if multiple VGA devices are found in the system. This can be one of the following:
• Onboard —Priority is given to the onboard VGA device.
BIOS post screen and OS boot are driven through the onboard VGA port.
• Offboard —Priority is given to the PCIE Graphics adapter.
BIOS post screen and OS boot are driven through the external graphics adapter port.
• Onboard VGA Disabled —Priority is given to the PCIE
Graphics adapter, and the onboard VGA device is disabled.
Serial Configuration Parameters
Name
Out-of-Band Mgmt Port
Description
Allows you to configure the COM port 0 that can be used for Windows
Emergency Management services. ACPI SPCR table is reported based on this setup option. This can be one of the following:
• Disabled —Configures the COM port 0 as a general purpose port for use with the Windows Operating System.
• Enabled —Configures the COM port 0 as a remote management port for Windows Emergency Management services.
434
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
BIOS Parameters by Server Model
Name
Console Redirection
Terminal Type
Bits per second
BIOS Parameters by Server Model
Description
Allows a serial port to be used for console redirection during POST and
BIOS booting. After the BIOS has booted and the operating system is responsible for the server, console redirection is irrelevant and has no effect. This can be one of the following:
• Disabled —No console redirection occurs during POST.
• COM 0 —Enables console redirection on COM port 0 during POST.
• COM 1 —Enables console redirection on COM port 1 during POST.
What type of character formatting is used for console redirection. This can be one of the following:
• PC-ANSI —The PC-ANSI terminal font is used.
• VT100 —A supported vt100 video terminal and its character set are used.
• VT100+ —A supported vt100-plus video terminal and its character set are used.
• VT-UTF8 —A video terminal with the UTF-8 character set is used.
Note This setting must match the setting on the remote terminal application.
What BAUD rate is used for the serial port transmission speed. If you disable Console Redirection, this option is not available. This can be one of the following:
• 9600 —A 9,600 BAUD rate is used.
• 19200 —A 19,200 BAUD rate is used.
• 38400 —A 38,400 BAUD rate is used.
• 57600 —A 57,600 BAUD rate is used.
• 115200 —A 115,200 BAUD rate is used.
Note This setting must match the setting on the remote terminal application.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
435
BIOS Parameters by Server Model
BIOS Parameters by Server Model
Name
Flow Control
Putty KeyPad
Description
Whether a handshake protocol is used for flow control. Request to Send
/ Clear to Send (RTS/CTS) helps to reduce frame collisions that can be introduced by a hidden terminal problem. This can be one of the following:
• None —No flow control is used.
• Hardware RTS/CTS —RTS/CTS is used for flow control.
Note This setting must match the setting on the remote terminal application.
Allows you to change the action of the PuTTY function keys and the top row of the numeric keypad. This can be one of the following:
• VT100 —The function keys generate ESC OP through ESC O[.
• LINUX —Mimics the Linux virtual console. Function keys F6 to
F12 behave like the default mode, but F1 to F5 generate ESC [[A through ESC [[E .
• XTERMR6 —Function keys F5 to F12 behave like the default mode. Function keys F1 to F4 generate ESC OP through ESC OS, which are the sequences produced by the top row of the keypad on
Digital terminals.
• SCO —The function keys F1 to F12 generate ESC [M through
ESC [X . The function and shift keys generate ESC [Y through
ESC [j . The control and function keys generate ESC [k through
ESC [v . The shift, control and function keys generate ESC [w through ESC [{ .
• ESCN —The default mode. The function keys match the general behavior of Digital terminals. The function keys generate sequences such as ESC [11~ and ESC [12~ .
• VT400 —The function keys behave like the default mode. The top row of the numeric keypad generates ESC OP through ESC OS .
Redirection After BIOS POST Whether BIOS console redirection should be active after BIOS POST is complete and control given to the OS bootloader. This can be one of the following:
• Always Enable —BIOS Legacy console redirection is active during the OS boot and run time.
• Bootloader —BIOS Legacy console redirection is disabled before giving control to the OS boot loader.
436
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
BIOS Parameters by Server Model
BIOS Parameters by Server Model
LOM and PCIe Slots Configuration Parameters
Name
CDN Support for VIC
Description
Whether the Ethernet Network naming convention is according to
Consistent Device Naming (CDN) or the traditional way of naming conventions. This can be one of the following:
• Disabled — CDN support for VIC cards is disabled.
• Enabled — CDN support is enabled for VIC cards.
Note CDN support for VIC cards work with Windows 2012 or the latest OS only.
PCI ROM CLP
PCH SATA Mode
All Onboard LOM Ports
LOM Port n OptionROM
PCI ROM Command Line Protocol (CLP) controls the execution of different Option ROMs such as PxE and iSCSI that are present in the card. By default, it is disabled.
• Enabled — Enables you to configure execution of different option
ROMs such as PxE and iSCSI for an individual ports separately.
• Disabled —The default option. You cannot choose different option
ROMs. A default option ROM is executed during PCI enumeration.
This options allows you to select the PCH SATA mode. This can be one of the following:
• AHCI —Sets both SATA and sSATA controllers to AHCI mode.
• Disabled —Disables both SATA and sSATA controllers.
• LSI SW Raid — Sets both SATA and sSATA controllers to raid mode for LSI SW Raid
Whether all LOM ports are enabled or disabled. This can be one of the following:
• Disabled —All LOM ports are disabled.
• Enabled —All LOM ports are enabled.
Whether Option ROM is available on the LOM port designated by n .
This can be one of the following:
• Disabled —The Option ROM for slot n is not available.
• Enabled —The Option ROM for slot n is available.
• UEFI Only —The Option ROM for slot n is available for UEFI only.
• Legacy Only —The Option ROM for slot n is available for legacy only.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
437
BIOS Parameters by Server Model
BIOS Parameters by Server Model
Name
All PCIe Slots OptionROM
PCIe Slot:n OptionROM
Description
Whether the server can use Option ROM present in the PCIe Cards.
This can be one of the following:
• Disabled —The Option ROM for slot n is not available.
• Enabled —The Option ROM for slot n is available.
• UEFI Only —The Option ROM for slot n is available for UEFI only.
• Legacy Only —The Option ROM for slot n is available for legacy only.
Whether the server can use the Option ROMs present in the PCIe Cards.
This can be one of the following:
• Disabled —The Option ROM for slot n is not available.
• Enabled —The Option ROM for slot n is available.
• UEFI Only —The Option ROM for slot n is available for UEFI only.
• Legacy Only —The Option ROM for slot n is available for legacy only.
PCIe Slot:MLOM OptionROM This options allows you to control the Option ROM execution of the
PCIe adapter connected to the MLOM slot. This can be one of the following:
• Enabled —Executes both legacy and UEFI Option ROM.
• Disabled —Both legacy and UEFI Option ROM will not be executed.
• UEFI Only —Executes only UEFI Option ROM.
• Legacy Only —Executes only Legacy Option ROM.
PCIe Slot:HBA OptionROM This options allows you to control the Option ROM execution of the
PCIe adapter connected to the HBA slot. This can be one of the following:
• Enabled —Executes both legacy and UEFI Option ROM.
• Disabled —Both legacy and UEFI Option ROM will not be executed.
• UEFI Only —Executes only UEFI Option ROM.
• Legacy Only —Executes only Legacy Option ROM.
438
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
BIOS Parameters by Server Model
BIOS Parameters by Server Model
Name
PCIe Slot:N1 OptionROM
PCIe Slot:N2 OptionROM
PCIe Slot:HBA Link Speed
PCIe SlotHBALinkSpeed
Description
This options allows you to control the Option ROM execution of the
PCIe adapter connected to the SSD:NVMe1 slot. This can be one of the following:
• Enabled —Executes both legacy and UEFI Option ROM.
• Disabled —Both legacy and UEFI Option ROM will not be executed.
• UEFI Only —Executes only UEFI Option ROM.
• Legacy Only —Executes only Legacy Option ROM.
This options allows you to control the Option ROM execution of the
PCIe adapter connected to the SSD:NVMe2 slot. This can be one of the following:
• Enabled —Executes both legacy and UEFI Option ROM.
• Disabled —Both legacy and UEFI Option ROM will not be executed.
• UEFI Only —Executes only UEFI Option ROM.
• Legacy Only —Executes only Legacy Option ROM.
This option allows you to restrict the maximum speed of an adapter card installed in PCIe HBA slot. This can be one of the following:
• Auto — System selects the maximum speed allowed.
• GEN1 —2.5GT/s (gigatransfers per second) is the maximum speed allowed.
• GEN2 —5GT/s is the maximum speed allowed.
• GEN3 —8GT/s is the maximum speed allowed.
• Disabled —The maximum speed is not restricted.
BIOS Configuration Dialog Box Button Bar
Important The buttons in this dialog box affect all BIOS parameters on all available tabs, not just the parameters on the tab that you are viewing.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
439
BIOS Parameters by Server Model
Server Management Tab for C220M4 and C240M4 Servers
Name
Save Changes button
Reset Values button
Restore Defaults button
Cancel button
Description
Saves the settings for the BIOS parameters on all three tabs and closes the dialog box.
If the Reboot Host Immediately check box is checked, the server is rebooted immediately and the new BIOS settings go into effect.
Otherwise the changes are saved until the server is manually rebooted.
Restores the values for the BIOS parameters on all three tabs to the settings that were in effect when this dialog box was first opened.
Sets the BIOS parameters on all three tabs to their default settings.
Closes the dialog box without making any changes.
Server Management Tab for C220M4 and C240M4 Servers
Reboot Server Option
If you want your changes applied automatically after you click Save Changes , check the Reboot Host
Immediately check box. Cisco IMC immediately reboots the server and applies your changes.
If you want to apply your changes at a later time, clear the Reboot Host Immediately check box. Cisco IMC stores the changes and applies them the next time the server reboots.
Note If there are existing BIOS parameter changes pending, Cisco IMC automatically overwrites the stored values with the current settings when you click Save Changes .
Server Management BIOS Parameters
Name
FRB-2 Timer
Description
Whether the FRB2 timer is used by Cisco IMC to recover the system if it hangs during POST. This can be one of the following:
• Disabled —The FRB2 timer is not used.
• Enabled —The FRB2 timer is started during POST and used to recover the system if necessary.
440
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
BIOS Parameters by Server Model
BIOS Parameters by Server Model
Name
OS Watchdog Timer
OS Watchdog Timer Timeout
OS Watchdog Timer Policy
Description
Whether the BIOS programs the watchdog timer with a specified timeout value. This can be one of the following:
• Disabled —The watchdog timer is not used to track how long the server takes to boot.
• Enabled —The watchdog timer tracks how long the server takes to boot. If the server does not boot within the length of time specified in the OS Boot Watchdog Timer
Timeout field, the Cisco IMC logs an error and takes the action specified in the OS Boot Watchdog Policy field.
If OS does not boot within the specified time, OS watchdog timer expires and system takes action according to timer policy.
This can be one of the following:
• 5 Minutes —The OS watchdog timer expires 5 minutes after it begins to boot.
• 10 Minutes —The OS watchdog timer expires 10 minutes after it begins to boot.
• 15 Minutes —The OS watchdog timer expires 15 minutes after it begins to boot.
• 20 Minutes —The OS watchdog timer expires 20 minutes after it begins to boot.
Note This option is only applicable if you enable the OS
Boot Watchdog Timer.
What action the system takes if the watchdog timer expires. This can be one of the following:
• Do Nothing —The server takes no action if the watchdog timer expires during OS boot.
• Power Down —The server is powered off if the watchdog timer expires during OS boot.
• Reset —The server is reset if the watchdog timer expires during OS boot.
Note This option is only applicable if you enable the OS
Boot Watchdog Timer.
BIOS Configuration Dialog Box Button Bar
Important The buttons in this dialog box affect all BIOS parameters on all available tabs, not just the parameters on the tab that you are viewing.
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1
441
BIOS Parameters by Server Model
BIOS Parameters by Server Model
Name
Save Changes button
Reset Values button
Restore Defaults button
Cancel button
Description
Saves the settings for the BIOS parameters on all three tabs and closes the dialog box.
If the Reboot Host Immediately check box is checked, the server is rebooted immediately and the new BIOS settings go into effect.
Otherwise the changes are saved until the server is manually rebooted.
Restores the values for the BIOS parameters on all three tabs to the settings that were in effect when this dialog box was first opened.
Sets the BIOS parameters on all three tabs to their default settings.
Closes the dialog box without making any changes.
442
Cisco UCS C-Series Integrated Management Controller GUI Configuration Guide, Release 4.1