C O N T E N T S
P R E F A C E
C H A P T E R 1
C H A P T E R 2
C H A P T E R 3
Related Cisco UCS Documentation xv
Storage Design Considerations 5
Storage Configuration Sequence 5
Effect of Port Mode Changes on Data Traffic 10
Displaying Port Properties and Fibre Channel Statistics 14
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
iii
Contents
Unconfiguring a Server Port 16
Guidelines for Configuring Unified Ports 17
Cautions and Guidelines for Configuring Unified Uplink Ports and Unified Storage Ports 18
Beacon LEDs for Unified Ports 19
Configuring the Beacon LEDs for Unified Ports 19
Unified Ports on the Fabric Interconnect 20
Configuring a Unified Storage Port 21
Configuring a Unified Uplink Port 22
Unified Uplink Port Channel 23
Configuring a Unified Uplink Port Channel 23
Cisco UCS Mini Scalability Ports 24
Configuring Scalability Ports 24
Configuring an Appliance Port 25
Assigning a Target MAC Address to an Appliance Port or Appliance Port Channel 27
Mapping an Appliance Port to a Community VLAN 29
Unconfiguring an Appliance Port 30
Configuring a FCoE Uplink Port 31
Unconfiguring a FCoE Uplink Port 33
FCoE and Fibre Channel Storage Ports 34
Configuring a Fibre Channel Storage or FCoE Port 34
Unconfiguring a Fibre Channel Storage or FCoE Port 34
Restoring a Fibre Channel Storage Port Back to an Uplink Fibre Channel Port 35
Configuring an Appliance Port Channel 36
Unconfiguring an Appliance Port Channel 38
Enabling or Disabling an Appliance Port Channel 38
Adding a Member Port to an Appliance Port Channel 39
iv
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
C H A P T E R 4
Deleting a Member Port from an Appliance Port Channel 40
Fibre Channel Port Channels 41
Configuring a Fibre Channel Port Channel 41
Unconfiguring a Fibre Channel Port Channel 42
Adding Channel Mode Active To The Upstream NPIV Fibre Channel Port Channel 43
Enabling or Disabling a Fibre Channel Port Channel 44
Adding a Member Port to a Fibre Channel Port Channel 45
Deleting a Member Port from a Fibre Channel Port Channel 46
Configuring Organizationally Unique Identifier 46
Configuring a FCoE Port Channel 47
Adding a Member Port to a FCoE Uplink Port Channel 48
Viewing Adapter Port Channels 49
Policy-Based Port Error Handling 51
Creating Threshold Definition 51
Configuring Error Disable on a Fabric Interconnect Port 53
Configuring Auto Recovery on a Fabric Interconnect Port 53
Viewing the Network Interface Port Error Counters 55
Cabling Considerations for Fabric Port Channels 56
Viewing Fabric Port Channels 57
Enabling or Disabling a Fabric Port Channel Member Port 58
Information About Fibre Channel Zoning 61
Information About Zone Sets 62
Support for Fibre Channel Zoning in Cisco UCS Manager 62
Cisco UCS Manager-Based Fibre Channel Zoning 62
Fibre Channel Storage Connection Policy 63
Contents
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
v
Contents
C H A P T E R 5
C H A P T E R 6
C H A P T E R 7
Fibre Channel Active Zone Set Configuration 63
Switch-Based Fibre Channel Zoning 64
Guidelines and recommendations for Cisco UCS Manager-Based Fibre Channel Zoning 64
Configuring Cisco UCS Manager Fibre Channel Zoning 64
Creating a VSAN for Fibre Channel Zoning 65
Creating a New Fibre Channel Zone Profile 67
Deleting a Fibre Channel Zone Profile 68
Deleting a Fibre Channel User Zone 68
Removing Unmanaged Zones from a VSAN Accessible to Both Fabric Interconnects 69
Removing Unmanaged Zones from a VSAN Accessible to One Fabric Interconnect 70
Configuring Fibre Channel Storage Connection Policies 71
Creating a Fibre Channel Storage Connection Policy 71
Deleting a Fibre Channel Storage Connection Policy 72
Fibre Channel Uplink Trunking for Named VSANs 76
Guidelines and Recommendations for VSANs 76
Creating a Named VSAN Accessible to Both Fabric Interconnects (Fibre Channel Uplink Mode) 78
Creating a Named VSAN Accessible to Both Fabric Interconnects (Fibre Channel Storage Mode) 79
Creating a Named VSAN Accessible to One Fabric Interconnect (Fibre Channel Uplink Mode) 80
Creating a Named VSAN Accessible to One Fabric Interconnect (Fibre Channel Storage Mode) 82
Changing the VLAN ID for the FCoE Native VLAN for a Named VSAN 84
Changing the VLAN ID for the FCoE Native VLAN for a Storage VSAN 85
Enabling or Disabling Fibre Channel Uplink Trunking 85
Configuring a SAN Pin Group 87
Configuring a FCoE Pin Group 88
vi
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
Contents
C H A P T E R 8
C H A P T E R 9
Configuring vHBA Templates 99 vHBA Template 99
Configuring a vHBA Template 99
Configuring Fibre Channel Adapter Policies 101
Ethernet and Fibre Channel Adapter Policies 101
Configuring a Fibre Channel Adapter Policy 104
Deleting a Fibre Channel Adapter Policy 106
Configuring the Default vHBA Behavior Policy 107
Default vHBA Behavior Policy 107
Configuring a Default vHBA Behavior Policy 107
Configuring SAN Connectivity Policies 108
About the LAN and SAN Connectivity Policies 108
Privileges Required for LAN and SAN Connectivity Policies 108
Interactions between Service Profiles and Connectivity Policies 109
Creating a SAN Connectivity Policy 109
Deleting a SAN Connectivity Policy 111
Creating a vHBA for a SAN Connectivity Policy 111
Deleting a vHBA from a SAN Connectivity Policy 114
Creating an Initiator Group for a SAN Connectivity Policy 114
Creating an SPDM Security Policy 116
Creating a SPDM Security Policy 117
Loading an Outside SPDM Security Certificate Policy 119
Displaying the Security Policy Fault Alert Level 120
Viewing the Certificate Inventory 120
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
vii
Contents
C H A P T E R 1 0
Deleting an Initiator Group from a SAN Connectivity Policy 122
Configuring an Aero Controller Storage Profile 123
Autoconfiguration Mode for Aero Storage Controllers 123
Creating an Autoconfiguation Profile 124
Cisco Boot Optimized M.2 RAID Controller 128
Disk Groups and Disk Group Configuration Policies 128
Supported LUN Modifications 133
Unsupported LUN Modifications 133
Non-Redundant Virtual Drives 134
Redundant Virtual Drives with No Hot Spare Drives 134
Redundant Virtual Drives with Hot Spare Drives 134
Replacing Hot Spare Drives 135
Inserting Physical Drives into Unused Slots 135
Controller Constraints and Limitations 136
Configuring Storage Profiles 138
Configuring a Disk Group Policy 138
Automatically Configuring Disks in a Disk Group 139
Manually Configuring Disks in a Disk Group 141
Configuring Virtual Drive Properties 143
Creating a Storage Profile 146
Deleting a Storage Profile 147
viii
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
Contents
C H A P T E R 1 1
Reordering Local LUNs In a Storage Profile 150
Deleting Local LUNs In a Storage Profile 151
Configuring Aero Controllers 156
Autoconfiguration Mode for Aero Storage Controllers 156
Creating an Autoconfiguation Profile 157
PCH Controller Definitions 158
PCH SSD Controller Definition 158
Creating a Storage Profile PCH Controller Definition 160
Deleting a Storage Profile PCH Controller Definition 162
Replacing a Faulty M.2 Disk 165
Associating a Storage Profile with a Service Profile 165
Displaying Details of All Local LUNs Inherited By a Service Profile 166
Importing Foreign Configurations for a RAID Controller 169
Configuring Local Disk Operations 169
Configuring Virtual Drive Properties 171
Deleting an Orphaned Virtual Drive 174
Renaming an Orphaned Virtual Drive 177
Boot Policy for Local Storage 177
Configuring the Boot Policy for a Local LUN 178
Configuring the Boot Policy for a Local JBOD Disk 179
Configuring the Boot Policy for an Embedded Local LUN 180
Configuring the Boot Policy for an Embedded Local Disk 181
Local LUN Operations in a Service Profile 183
Preprovisioning a LUN Name or Claiming an Orphan LUN 183
Deploying and Undeploying a LUN 184
Renaming a Service Profile Referenced LUN 185
Configuring SD Card Support 187
FlexFlash Secure Digital Card Support 187
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
ix
Contents
C H A P T E R 1 2
C H A P T E R 1 3
FlexUtil Secure Digital Card Support 189
Viewing Mini Storage Properties 191
Viewing the Storage Controller for the Mini Storage 192
Security Policies for Self-Encrypting Drives 195
Security Flags of the Controller and Disk 196
Managing Local Security Policies 197
Creating a Local Security Policy 197
Modifying the Security Key of a Local Security Policy 198
Modifying the Security Policy from Local to Remote 199
Inserting a Secured Disk into a Server with a Local Security Policy 201
KMIP Client Certificate Policy 202
Creating a Global KMIP Client Certificate Policy 202
Creating a KMIP Client Certificate for a Server 204
Managing Remote Security Policies 206
Creating a Remote Security Policy 206
Modifying a Remote Security Key 208
Modifying the Security Policy from Remote to Local 209
Inserting a Secured Disk into a Server with a Remote Security Policy 210
Securing an Existing Virtual Drive 211
Enabling Security on a Disk 212
Disabling Security on a Controller 214
Erasing a Secure Foreign Configuration Disk 216
Displaying the Security Flags of a Controller 217
Displaying the Security Flags of a Local Disk 219
Displaying the Security Flags of a Virtual Drive 221
x
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
C H A P T E R 1 4
C H A P T E R 1 5
Volume Management Device (VMD) Setup 225
Cisco UCS S3260 System Storage Management 227
Storage Server Features and Components Overview 227
Cisco UCS S3260 Storage Management Operations 235
Disk Sharing for High Availability 236
Creating a Disk Zoning Policy 237
Creating Disk Slots and Assigning Ownership 237
Associating Disk Zoning Policies to Chassis Profile 239
Storage Enclosure Operations 240
Removing Chassis Level Storage Enclosures 240
SAS Expander Configuration Policy 241
Creating SAS Expander Configuration Policy 241
Deleting a SAS Expander Configuration Policy 242
Contents
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
xi
Contents xii
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
Preface
•
•
•
Related Cisco UCS Documentation, on page xv
•
Documentation Feedback, on page xv
Audience
This guide is intended primarily for data center administrators with responsibilities and expertise in one or more of the following:
• Server administration
• Storage administration
• Network administration
• Network security
Conventions
Text Type
GUI elements
Document titles
TUI elements
System output
CLI commands
[ ]
Indication
GUI elements such as tab titles, area names, and field labels appear in this font .
Main titles such as window, dialog box, and wizard titles appear in this font .
Document titles appear in this font .
In a Text-based User Interface, text the system displays appears in this font .
Terminal sessions and information that the system displays appear in this font .
CLI command keywords appear in this font .
Variables in a CLI command appear in this font .
Elements in square brackets are optional.
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
xiii
Preface
Preface
Text Type
{x | y | z}
[x | y | z] string
< >
[ ]
!, #
Indication
Required alternative keywords are grouped in braces and separated by vertical bars.
Optional alternative keywords are grouped in brackets and separated by vertical bars.
A nonquoted set of characters. Do not use quotation marks around the string or the string will include the quotation marks.
Nonprinting characters such as passwords are in angle brackets.
Default responses to system prompts are in square brackets.
An exclamation point (!) or a pound sign (#) at the beginning of a line of code indicates a comment line.
Note Means reader take note . Notes contain helpful suggestions or references to material not covered in the document.
Tip Means the following information will help you solve a problem . The tips information might not be troubleshooting or even an action, but could be useful information, similar to a Timesaver.
Timesaver Means the described action saves time . You can save time by performing the action described in the paragraph.
Caution Means reader be careful . In this situation, you might perform an action that could result in equipment damage or loss of data.
Warning IMPORTANT SAFETY INSTRUCTIONS
This warning symbol means danger. You are in a situation that could cause bodily injury. Before you work on any equipment, be aware of the hazards involved with electrical circuitry and be familiar with standard practices for preventing accidents. Use the statement number provided at the end of each warning to locate its translation in the translated safety warnings that accompanied this device.
SAVE THESE INSTRUCTIONS xiv
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
Preface
Related Cisco UCS Documentation
Related Cisco UCS Documentation
Documentation Roadmaps
For a complete list of all B-Series documentation, see the Cisco UCS B-Series Servers Documentation Roadmap available at the following URL: https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/overview/ guide/UCS_roadmap.html
For a complete list of all C-Series documentation, see the Cisco UCS C-Series Servers Documentation Roadmap available at the following URL: https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/overview/ guide/ucs_rack_roadmap.html
.
For information on supported firmware versions and supported UCS Manager versions for the rack servers that are integrated with the UCS Manager for management, refer to Release Bundle Contents for Cisco UCS
Software .
Other Documentation Resources
Follow Cisco UCS Docs on Twitter to receive document update notifications.
Documentation Feedback
To provide technical feedback on this document, or to report an error or omission, please send your comments to [email protected]
. We appreciate your feedback.
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
xv
Documentation Feedback
Preface xvi
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
C H A P T E R
1
New and Changed Information
•
New and Changed Information, on page 1
New and Changed Information
This section provides information on new feature and changed behavior in Cisco UCS Manager, Release 4.2.
Table 1: New Features and Changed Behavior in Cisco UCS Manager, Release 4.2(1i)
Feature
Cisco UCS M6 servers
Description Where Documented
Added Cisco UCS C245 M6 Server support with:
• UCS-M2-HWRAID
• UCS C245 M6SX
Table 2: New Features and Changed Behavior in Cisco UCS Manager, Release 4.2(1f)
Feature Description Where Documented
Disable Local Storage RAID level Added Disable Local Storage
RAID level to support PCH SATA
Controller (AHCI mode).
and
Creating a Storage Profile PCH
Controller Definition, on page 160
Table 3: New Features and Changed Behavior in Cisco UCS Manager, Release 4.2(1d)
Feature
Cisco UCS M6 servers
Description Where Documented
Cisco UCS Manager now supports
Cisco UCS C220 M6 and UCS
C240 M6 C-series servers.
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
1
New and Changed Information
New and Changed Information
Feature
Cisco UCS M6 controllers
Auto Config Mode for Aero
Controllers
Description Where Documented
Cisco UCS Manager now supports
Cisco UCSC-C220-M6,
UCSC-C240-M6, and
UCSB-MRAID12G-M6 controllers.
Cisco UCS Manager now lets you choose whether to use an automatic configuration option for storage devices on M6 servers with Aero storage controllers.
Autoconfiguration Mode for Aero
Storage Controllers, on page 123
Security Protocol and Data Model
(SPDM)
SPDM can now be used for authentication with the storage controller. It can be used either natively or by uploading outside security certificates.
SPDM Authentication, on page 117
2
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
C H A P T E R
2
Overview
•
•
•
Storage Design Considerations, on page 5
•
Storage Configuration Sequence, on page 5
•
•
The UCS Manager SAN Tab, on page 6
Overview
This guide describes how to configure the following storage management tasks:
• Ports and Port Channels
• Named VSANs
• SAN Pin Groups
• SAN Uplinks
• Pools
• FC Identity Assignment
• Storage-Related Policies
• Storage Profiles
• FlexFlash SD Card Support
• Direct Attached Storage
• Storage Inventory
Storage Options
The following are the UCS Manager storage options and the benefits of each.
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
3
Storage Options
Figure 1: Cisco UCS Manager Storage Options
Overview
• Direct Attached Storage (DAS) —This is the storage available inside a server and is directly connected to the system through the motherboard within a parallel SCSI implementation. DAS is commonly described as captive storage. Devices in a captive storage topology do not have direct access to the storage network and do not support efficient sharing of storage. To access data with DAS, a user must go through a front-end network. DAS devices provide little or no mobility to other servers and little scalability.
DAS devices limit file sharing and can be complex to implement and manage. For example, to support data backups, DAS devices require resources on the host and spare disk systems that other systems cannot use. The cost and performance of this storage depends upon the disks and RAID controller cards inside the servers. DAS is less expensive and is simple to configure; however, it lacks the scalability, performance, and advanced features provided by high-end storage.
• Network Attached Storage (NAS) —This storage is usually an appliance providing file system access.
This storage could be as simple as an Network File System (NFS) or Common Internet File System
(CIFS) share available to the servers. Typical NAS devices are cost-effective devices with not very high performance but have very high capacity with some redundancy for reliability. NAS is usually moderately expensive, simple to configure, and provides some advanced features; however, it also lacks scalability, performance, and advanced features provided by SAN.
• Storage Area Network (SAN) —A SAN is a specialized, high-speed network that attaches servers and storage devices. A SAN allows an any-to-any connection across the network by using interconnect elements, such as switches and directors. It eliminates the traditional dedicated connection between a server and storage, and the concept that the server effectively owns and manages the storage devices. It also eliminates any restriction to the amount of data that a server can access, currently limited by the number of storage devices that are attached to the individual server. Instead, a SAN introduces the flexibility of networking to enable one server or many heterogeneous servers to share a common storage utility. A network might include many storage devices, including disk, tape, and optical storage.
Additionally, the storage utility might be located far from the servers that it uses. This type of storage
4
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
Overview
Storage Design Considerations provides maximum reliability, expandability, and performance. The cost of SAN is also very high compared to other storage options.
SAN is the most resilient, highly scalable, and high performance storage; however, it is also the most expensive and complex to manage.
Storage Design Considerations
UCS storage physical connectivity has a slightly different design consideration as compared to LAN physical connectivity. The following are some design considerations for SAN connectivity:
• Northbound storage physical connectivity does not support virtual port channels (vPCs) like LAN connectivity.
• Port channels or trunking is possible to combine multiple storage uplink ports that provide physical link redundancy.
• Redundancy of storage resources is handled by the storage itself and varies from vendor to vendor.
• Connect storage through northbound Cisco storage devices, such as Nexus or MDS Fabric Switches.
• It is possible to connect storage directly to UCS Fabric Interconnects, which is recommended for small implementations because of the fabric interconnect physical ports consumption and increased processing requirements.
• Software configuration including VSANs and zoning is required for providing access to storage resources.
Storage Configuration Sequence
Follow the suggested sequence to configure a storage network:
1.
Configure and enable server ports, uplink ports, and FC ports.
2.
Create a management IP address pool (typically on the same subnet as the UCS Manager Admin IP address).
3.
Create an UUID Pool, MAC Pool, WWNN Pool, WWPN Pool (or populate the corresponding "default" pools). Embed domain ID's. Use Fabric-specific Pools for MAC and WWPN (for example, Fabric-A,
Fabric-B).
4.
For SAN boot, create a unique "Boot Policy" for each storage array boot target.
5.
Create VNIC templates (for example, eth0-A, eth1-B) that both draw from the above MAC Pool, and are associated with Fabric-A and Fabric-B respectively.
6.
Create VHBA templates (for example, fc0-A, fc1-B) that both draw from the above WWPN Pool, and are associated with Fabric-A and Fabric-B respectively.
7.
Create service profile templates that draw from all earlier established pools, policies and templates, as appropriate.
8.
Instantiate the service profile from the template and associate the service profile to a given blade, or set the service profile template to associate with a particular server pool.
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
5
Overview
Storage Protocols
Storage Protocols
Fiber Channel, iSCSI, and Fiber Channel over Ethernet are protocols for SAN connectivity.
• iSCSI —An industry standard protocol for attaching various I/O peripherals such as printers, scanners, tape drives, and storage devices. The most common SCSI devices are disks and tape libraries.
SCSI is the core protocol to connect raw hard disk storage with the servers. To control remote storage with the SCSI protocol, different technologies are used as wrappers to encapsulate commands, such as
FC and iSCSI.
Fiber Channel protocol provides the infrastructure to encapsulate the SCSI traffic and provided connectivity between computers and storage. FC operates at speeds of 2, 4, 8, and 16 Gbps.
• Fiber Channel (FC) consists of the following:
• Hard disk arrays that provide raw storage capacity.
• Storage processors to manage hard disks and provide storage LUNs and masking for the servers.
• Fiber Channel Switches (also known as Fabric) that provide connectivity between storage processors and server HBAs.
• Fiber Channel Host Bus Adapters: They are installed in the computer and provide connectivity to the SAN.
Fiber Channel identifies infrastructure components with World Wide Numbers (WWN) . WWNs are
64-bit addresses which uniquely identify the FC devices. Like MAC addresses, it has bits assigned to vendors to identify their devices. Each end device (like an HBA port) is given a World Wide Port Number
(WWPN) and each connectivity device (like a Fabric switch) is given a World Wide Node Number
(WWNN).
A Fiber Chanel HBA used for connecting to a SAN is known as an initiator, and Fiber Channel SAN providing disks as LUNs is known as a target. The Fiber Channel protocol is different from Ethernet or
TCP/IP protocols.
• Fiber Channel over Ethernet (FCoE) transport replaces the Fibre Channel cabling with 10 Gigabit
Ethernet cables and provides lossless delivery over unified I/O. Ethernet is widely used in networking.
With some advancement such as Data Center Ethernet (DCE) and Priority Flow Control (PFC) in Ethernet to make it more reliable for the datacenter, Fiber Channel is now also implemented on top of Ethernet.
This implementation is known as FCoE.
The UCS Manager SAN Tab
From the SAN tab, you the UCS administrator can create, modify, and delete configuration elements related to SANs (FC, iSCSI) or direct attached FC/FCoE, NAS appliances, and communications.
The major nodes in this tab are the following:
• SAN Cloud —Ths node allows you to:
• Configure SAN uplinks, including storage ports and port channels and SAN pin groups.
• View the FC identity assignment
6
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
Overview
The UCS Manager SAN Tab
• Configure WWN Pools, including WWPN, WWxN, and WWxN, and iSCSI Qualified Name (IQN), pools.
• View the FSM details for a particular end point to determine if a task succeeded or failed and use the FSM to troubleshoot any failures.
• Monitor storage events and faults for health management.
• Storage Cloud —This node allows you to:
• Configure storage FC links and storage FCoE interfaces (using SAN Storage Manager.
• Configure VSAN settings.
• Monitor SAN cloud events for health management.
• Policies —This node allows you to:
• Configure threshold policies, classes, and properties and monitor events.
• Configure threshold organization and sub-organization storage policies, including default VHBA, behavior, FC adaptor, LACP, SAN connectivity, SAN connector, and VHBA templates.
• Pools —This node allows you to configure pools defined in the system, including IQN, IQN suffix,
WWNN, WWPN, and WWxN.
• Traffic Monitoring Sessions —This node allows you to configure port traffic monitoring sessions defined in the system.
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
7
The UCS Manager SAN Tab
Overview
8
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
C H A P T E R
3
SAN Ports and Port Channels
•
•
•
Effect of Port Mode Changes on Data Traffic, on page 10
•
FC Links Rebalancing, on page 11
•
Configuring the Port Mode, on page 12
•
Displaying Port Properties and Fibre Channel Statistics, on page 14
•
•
•
Cisco UCS Mini Scalability Ports, on page 24
•
•
•
FCoE and Fibre Channel Storage Ports, on page 34
•
Appliance Port Channels, on page 36
•
Fibre Channel Port Channels, on page 41
•
FCoE Port Channels, on page 47
•
Adapter Port Channels, on page 49
•
Event Detection and Action, on page 50
•
Fabric Port Channels, on page 55
Port Modes
The port mode determines whether a unified port on the fabric interconnect is configured to carry Ethernet or Fibre Channel traffic. You configure the port mode in Cisco UCS Manager. However, the fabric interconnect does not automatically discover the port mode.
Changing the port mode deletes the existing port configuration and replaces it with a new logical port. Any objects associated with that port configuration, such as VLANs and VSANS, are also removed. There is no restriction on the number of times you can change the port mode for a unified port.
Port Types
The port type defines the type of traffic carried over a unified port connection.
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
9
SAN Ports and Port Channels
Effect of Port Mode Changes on Data Traffic
By default, unified ports changed to Ethernet port mode are set to the Ethernet uplink port type. Unified ports changed to Fibre Channel port mode are set to the Fibre Channel uplink port type. You cannot unconfigure
Fibre Channel ports.
Changing the port type does not require a reboot.
Ethernet Port Mode
When you set the port mode to Ethernet, you can configure the following port types:
• Server ports
• Ethernet uplink ports
• Ethernet port channel members
• FCoE ports
• Appliance ports
• Appliance port channel members
• SPAN destination ports
• SPAN source ports
Note For SPAN source ports, configure one of the port types and then configure the port as SPAN source.
Fibre Channel Port Mode
When you set the port mode to Fibre Channel, you can configure the following port types:
• Fibre Channel uplink ports
• Fibre Channel port channel members
• Fibre Channel storage ports
• FCoE Uplink ports
• SPAN source ports
Note For SPAN source ports, configure one of the port types and then configure the port as SPAN source.
Effect of Port Mode Changes on Data Traffic
Port mode changes can cause an interruption to the data traffic for the Cisco UCS domain. The length of the interruption and the traffic that is affected depend upon the configuration of the Cisco UCS domain and the module on which you made the port mode changes.
10
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
SAN Ports and Port Channels
FC Links Rebalancing
Tip To minimize the traffic disruption during system changes, form a Fibre Channel uplink port-channel across the fixed and expansion modules.
Impact of Port Mode Changes on an Expansion Module
After you make port mode changes on an expansion module, the module reboots. All traffic through ports on the expansion module is interrupted for approximately one minute while the module reboots.
Impact of Port Mode Changes on the Fixed Module in a Cluster Configuration
A cluster configuration has two fabric interconnects. After you make port changes to the fixed module, the fabric interconnect reboots. The impact on the data traffic depends upon whether or not you have configured the server vNICs to failover to the other fabric interconnect when one fails.
If you change the port modes on the expansion module of one fabric interconnect and then wait for that to reboot before changing the port modes on the second fabric interconnect, the following occurs:
• With server vNIC failover, traffic fails over to the other fabric interconnect and no interruption occurs.
• Without server vNIC failover, all data traffic through the fabric interconnect on which you changed the port modes is interrupted for approximately eight minutes while the fabric interconnect reboots.
If you change the port modes on the fixed modules of both fabric interconnects simultaneously, all data traffic through the fabric interconnects are interrupted for approximately eight minutes while the fabric interconnects reboot.
Impact of Port Mode Changes on the Fixed Module in a Standalone Configuration
A standalone configuration has only one fabric interconnect. After you make port changes to the fixed module, the fabric interconnect reboots. All data traffic through the fabric interconnect is interrupted for approximately eight minutes while the fabric interconnect reboots.
FC Links Rebalancing
The FC uplinks balance automatically when FC Port Channels are utilized. To create FC Port Channels, refer to
Configuring a Fibre Channel Port Channel, on page 41 .
For the FC uplinks that are not members of the Port Channels (Individual ISLs), load balancing is done according to the FC uplinks balancing algorithm. For a vHBA of a host or service profile to choose an available
FC uplink, when FC uplink trunking is disabled, the uplink and vHBA must belong to the same VSAN
For each vHBA, the algorithm searches for an FC uplink in the following order:
1.
Least used FC uplink based on the number of vHBAs currently bound to the uplink.
2.
If FC uplinks are equally balanced, then round robin is used.
This process continues for all the other vHBAs. The algorithm also considers other parameters such as pre-fip/fip adapters and number of flogis. You may not see the least-used component when there are less than six flogis.
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
11
SAN Ports and Port Channels
Configuring the Port Mode
After a port configuration or any other uplink state changes, if the traffic passing through the FC uplinks is no longer balanced, you can re-balance the traffic by resetting the vHBA(s) on each adapter and allow the load balancing algorithm to evaluate for the current state of the FC uplinks.
Configuring the Port Mode
Caution Changing the port mode on either module can cause an interruption in data traffic because changes to the fixed module require a reboot of the fabric interconnect and changes on an expansion module require a reboot of that module .
If the Cisco UCS domain has a cluster configuration that is set up for high availability and servers with service profiles that are configured for failover, traffic fails over to the other fabric interconnect and data traffic is not interrupted when the port mode is changed on the fixed module.
In the Cisco UCS Manager CLI, there are no new commands to support Unified Ports. Instead, you change the port mode by scoping to the mode for the desired port type and then creating a new interface. When you create a new interface for an already configured slot ID and port ID, UCS Manager deletes the previously configured interface and creates a new one. If a port mode change is required because you configure a port that previously operated in Ethernet port mode to a port type in Fibre Channel port mode, UCS Manager notes the change.
SUMMARY STEPS
1.
UCS-A# scope port-type-mode
2.
UCS-A / port-type-mode # scope fabric { a | b }
3.
UCS-A / port-type-mode /fabric # create interface slot-id port-id
4.
Create new interfaces for other ports belonging to the Ethernet or Fibre Channel port block.
5.
UCS-A / port-type-mode /fabric/interface # commit-buffer
DETAILED STEPS
Step 1
Command or Action
UCS-A# scope port-type-mode
Purpose
Enters the specified port type mode for one of the following port types: eth-server
For configuring server ports.
eth-storage
For configuring Ethernet storage ports and Ethernet storage port channels.
eth-traffic-mon
For configuring Ethernet SPAN ports.
eth-uplink
For configuring Ethernet uplink ports.
12
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
SAN Ports and Port Channels
Configuring the Port Mode
Step 2
Step 3
Step 4
Step 5
Command or Action Purpose fc-storage
For configuring Fibre Channel storage ports.
fc-traffic-mon
For configuring Fibre Channel SPAN ports.
fc-uplink
For configuring Fibre Channel uplink ports and Fibre
Channel uplink port channels.
Enters the specified port type mode for the specified fabric.
UCS-A / port-type-mode # scope fabric { a | b }
UCS-A / port-type-mode /fabric # create interface slot-id port-id
Creates an interface for the specified port type.
If you are changing the port type from Ethernet port mode to Fibre Channel port mode, or vice-versa, the following warning appears:
Warning: This operation will change the port mode
(from Ethernet to FC or vice-versa). When committed, this change will require the module to restart.
Create new interfaces for other ports belonging to the
Ethernet or Fibre Channel port block.
There are several restrictions that govern how Ethernet and
Fibre Channel ports can be arranged on a fixed or expansion module. Among other restrictions, it is required that you change ports in groups of two. Violating any of the restrictions outlined in the
section will result in an error.
UCS-A / port-type-mode /fabric/interface # commit-buffer Commits the transaction to the system configuration.
Based on the module for which you configured the port modes, data traffic for the Cisco UCS domain is interrupted as follows:
• Fixed module—The fabric interconnect reboots. All data traffic through that fabric interconnect is interrupted. In a cluster configuration that provides high availability and includes servers with vNICs that are configured for failover, traffic fails over to the other fabric interconnect and no interruption occurs.
It takes about 8 minutes for the fixed module to reboot.
• Expansion module—The module reboots. All data traffic through ports in that module is interrupted.
It takes about 1 minute for the expansion module to reboot.
Example
The following example changes ports 3 and 4 on slot 1 from Ethernet uplink ports in Ethernet port mode to uplink Fibre Channel ports in Fibre Channel port mode:
UCS-A# scope fc-uplink
UCS-A /fc-uplink # scope fabric a
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
13
SAN Ports and Port Channels
Displaying Port Properties and Fibre Channel Statistics
UCS-A /fc-uplink/fabric # create interface 1 3
Warning: This operation will change the port mode (from Ethernet to FC or vice-versa).
When committed, this change will require the fixed module to restart.
UCS-A /fc-uplink/fabric/interface* # up
UCS-A /fc-uplink/fabric* # create interface 1 4
Warning: This operation will change the port mode (from Ethernet to FC or vice-versa).
When committed, this change will require the fixed module to restart.
UCS-A /fc-uplink/fabric/interface* # commit-buffer
Displaying Port Properties and Fibre Channel Statistics
SUMMARY STEPS
1.
UCS-A /fabric-interconnect # connect nxos { a | b
2.
UCS-A(nxos)# show interface fc slot-id / port-id
DETAILED STEPS
Step 1
Step 2
Command or Action
UCS-A /fabric-interconnect # connect nxos { a | b
UCS-A(nxos)# show interface fc slot-id / port-id
Purpose
Enters NX-OS mode for the fabric interconnect.
Displays the port properties and Fibre Channel statistics such as throughput rates and errors.
Note The receive B2B credit remaining on a UCS
6400 Series fabric interconnect does not match the transmit B2B credit remaining on its peer switch. The receive B2B credit remaining parameter always remains at 64 because the credit is returned when the frame is released. On an MDS peer, the transmit B2B credit remaining parameter can go to 0. This results in the mismatch. You can run the show interface
fc slot-id / port-id command on the peer switch to compare these parameters.
Example
The following example displays port properties and Fibre Channel statistics for UCS 6400 Series fabric interconnects:
UCS-A /fabric-interconnect # connect nxos a
UCS-A(nxos)# show interface fc 1/6 fc1/6 is trunking
Hardware is Fibre Channel, SFP is short wave laser w/o OFC (SN)
Port WWN is 20:06:00:de:fb:21:77:00
Admin port mode is NP, trunk mode is on snmp link state traps are enabled
Port mode is TNP
Port vsan is 8
Speed is 16 Gbps
14
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
SAN Ports and Port Channels
Server Ports
Transmit B2B Credit is 32
Receive B2B Credit is 64
Receive data field Size is 2112
Beacon is turned off
Belongs to san-port-channel 32
Trunk vsans (admin allowed and active) (1,5,7-8,40,120)
Trunk vsans (up) (1,5,7-8,40,120)
Trunk vsans (isolated)
Trunk vsans (initializing)
()
()
5 minutes input rate 497578904 bits/sec,62197363 bytes/sec, 30981 frames/sec
5 minutes output rate 501679056 bits/sec,62709882 bytes/sec, 30319 frames/sec
430000799 frames input,863205473268 bytes
0 discards,0 errors
0 invalid CRC/FCS,0 unknown class
0 too long,0 too short
423530360 frames output,876009587416 bytes
0 discards,0 errors
1 input OLS,1 LRR,9 NOS,0 loop inits
1 output OLS,0 LRR, 8 NOS, 0 loop inits
64 receive B2B credit remaining
32 transmit B2B credit remaining
0 low priority transmit B2B credit remaining
Last clearing of "show interface" counters :never
Server Ports
Configuring a Server Port
All of the port types listed are configurable on both the fixed and expansion module, including server ports, which are not configurable on the 6100 series fabric interconnect expansion module, but are configurable on the 6200 series fabric interconnect expansion module.
SUMMARY STEPS
1.
UCS-A# scope eth-server
2.
UCS-A /eth-server # scope fabric { a | b }
3.
UCS-A /eth-server/fabric # create interface slot-num port-num
4.
UCS-A /eth-server/fabric # commit-buffer
DETAILED STEPS
Step 1
Step 2
Command or Action
UCS-A# scope eth-server
UCS-A /eth-server # scope fabric { a | b }
Step 3
Step 4
UCS-A /eth-server/fabric # create interface slot-num port-num
UCS-A /eth-server/fabric # commit-buffer
Purpose
Enters Ethernet server mode.
Enters Ethernet server fabric mode for the specified fabric.
Creates an interface for the specified Ethernet server port.
Commits the transaction to the system configuration.
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
15
SAN Ports and Port Channels
Unconfiguring a Server Port
Example
The following example shows how to create an interface for Ethernet server port 4 on slot 1 of fabric
B and commit the transaction:
UCS-A# scope eth-server
UCS-A /eth-server # scope fabric b
UCS-A /eth-server/fabric # create interface 1 4
UCS-A /eth-server/fabric* # commit-buffer
UCS-A /eth-server/fabric #
Unconfiguring a Server Port
SUMMARY STEPS
1.
UCS-A# scope eth-server
2.
UCS-A /eth-server # scope fabric { a | b }
3.
UCS-A /eth-server/fabric # delete interface slot-num port-num
4.
UCS-A /eth-server/fabric # commit-buffer
DETAILED STEPS
Step 1
Step 2
Command or Action
UCS-A# scope eth-server
UCS-A /eth-server # scope fabric { a | b }
Step 3
Step 4
UCS-A /eth-server/fabric # delete interface slot-num port-num
UCS-A /eth-server/fabric # commit-buffer
Purpose
Enters Ethernet server mode.
Enters Ethernet server fabric mode for the specified fabric.
Deletes the interface for the specified Ethernet server port.
Commits the transaction to the system configuration.
Example
The following example unconfigures Ethernet server port 12 on slot 1 of fabric B and commits the transaction:
UCS-A# scope eth-server
UCS-A /eth-server # scope fabric b
UCS-A /eth-server/fabric # delete interface 1 12
UCS-A /eth-server/fabric* # commit-buffer
UCS-A /eth-server/fabric #
16
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
SAN Ports and Port Channels
Unified Ports
Unified Ports
Guidelines for Configuring Unified Ports
Consider the following guidelines and restrictions when configuring unified ports:
Hardware and Software Requirements
Unified ports are supported on the following:
• Cisco UCS 64108 Fabric Interconnect with Cisco UCS Manager Release 4.1 and later releases
• Cisco UCS 6454 Fabric Interconnect with Cisco UCS Manager Release 4.0 and later releases
• UCS 6300 Series Fabric Interconnects with Cisco UCS Manager Release 3.1 and later releases
• UCS 6200 Series Fabric Interconnects with Cisco UCS Manager Release 2.0 and later releases
• UCS 6324 Fabric Interconnects with Cisco UCS Manager Release 3.0 and later releases
Unified ports are not supported on 6100 series Fabric Interconnects, even if they are running Cisco UCS
Manager, version 2.0.
Port Mode Placement
Because the Cisco UCS Manager GUI interface uses a slider to configure the port mode for unified ports on a fixed or expansion module, it automatically enforces the following restrictions which limits how port modes can be assigned to unified ports. When using the Cisco UCS Manager CLI interface, these restrictions are enforced when you commit the transaction to the system configuration. If the port mode configuration violates any of the following restrictions, the Cisco UCS Manager CLI displays an error:
• Ethernet ports must be grouped together in a block. For each module (fixed or expansion), the Ethernet port block must start with the first port and end with an even numbered port.
• Fibre Channel ports must be grouped together in a block. For each module (fixed or expansion), the first port in the Fibre Channel port block must follow the last Ethernet port and extend to include the rest of the ports in the module. For configurations that include only Fibre Channel ports, the Fibre Channel block must start with the first port on the fixed or expansion module.
Note On the Cisco UCS 6400 Series Fabric Interconnect, the Unified Port capability is restricted to first 16 ports. Only ports 1/1-1/16 can be configured as FC. The
FC ports must be contiguous, followed by contiguous Ethernet ports.
• On the Cisco UCS 6400 Series Fabric Interconnect connected to a Cisco UCS server, connecting more than 16 ports will result in an error.
• Alternating Ethernet and Fibre Channel ports is not supported on a single module.
Example of a valid configuration — Might include unified ports 1–16 on the fixed module configured in
Ethernet port mode and ports 17–32 in Fibre Channel port mode. On the expansion module you could configure
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
17
SAN Ports and Port Channels
Cautions and Guidelines for Configuring Unified Uplink Ports and Unified Storage Ports ports 1–4 in Ethernet port mode and then configure ports 5–16 in Fibre Channel mode. The rule about alternating
Ethernet and Fibre Channel port types is not violated because this port arrangement complies with the rules on each individual module.
Example of an invalid configuration — Might include a block of Fibre Channel ports starting with port 16.
Because each block of ports has to start with an odd-numbered port, you would have to start the block with port 17.
Note The total number of uplink Ethernet ports and uplink Ethernet port channel members that can be configured on each fabric interconnect is limited to 31. This limitation includes uplink Ethernet ports and uplink Ethernet port channel members configured on the expansion module.
Cautions and Guidelines for Configuring Unified Uplink Ports and Unified
Storage Ports
The following are cautions and guidelines to follow while working with unified uplink ports and unified storage ports:
• In an unified uplink port, if you enable one component as a SPAN source, the other component will automatically become a SPAN source.
Note If you create or delete a SPAN source under the Ethernet uplink port, Cisco UCS
Manager automatically creates or deletes a SPAN source under the FCoE uplink port. The same happens when you create a SPAN source on the FCOE uplink port.
• You must configure a non default native VLAN on FCoE and unified uplink ports. This VLAN is not used for any traffic. Cisco UCS Manager will reuse an existing fcoe-storage-native-vlan for this purpose.
This fcoe-storage-native-vlan will be used as a native VLAN on FCoE and unified uplinks.
• In an unified uplink port, if you do not specify a non default VLAN for the Ethernet uplink port the fcoe-storage-native-vlan will be assigned as the native VLAN on the unified uplink port. If the Ethernet port has a non default native VLAN specified as native VLAN, this will be assigned as the native VLAN for unified uplink port.
• When you create or delete a member port under an Ethernet port channel, Cisco UCS Manager automatically creates or deletes the member port under FCoE port channel. The same happens when you create or delete a member port in FCoE port channel.
• When you configure an Ethernet port as a standalone port, such as server port, Ethernet uplink, FCoE uplink or FCoE storage and make it as a member port for an Ethernet or FCOE port channel, Cisco UCS
Manager automatically makes this port as a member of both Ethernet and FCoE port channels.
• When you remove the membership for a member port from being a member of server uplink, Ethernet uplink, FCoE uplink or FCoE storage, Cisco UCS Manager deletes the corresponding members ports from Ethernet port channel and FCoE port channel and creates a new standalone port.
18
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
SAN Ports and Port Channels
Beacon LEDs for Unified Ports
• If you downgrade Cisco UCS Manager from release 2.1 to any of the prior releases, all unified uplink ports and port channels will be converted to Ethernet ports and Ethernet port channels when the downgrade is complete. Similarly, all the unified storage ports will be converted to appliance ports.
• For unified uplink ports and unified storage ports, when you create two interfaces, only one license is checked out. As long as either interface is enabled, the license remains checked out. The license will be released only if both the interfaces are disabled for a unified uplink port or a unified storage port.
• Cisco UCS 6100 series fabric interconnect switch can only support 1VF or 1VF-PO facing same downstream NPV switch.
Beacon LEDs for Unified Ports
Each port on the 6200 series fabric interconnect has a corresponding beacon LED. When the Beacon LED property is configured, the beacon LEDs illuminate, showing you which ports are configured in a given port mode.
You can configure the Beacon LED property to show you which ports are grouped in one port mode: either
Ethernet or Fibre Channel. By default, the Beacon LED property is set to Off.
Note For unified ports on the expansion module, you can reset the Beacon LED property to the default value of
Off during expansion module reboot.
Configuring the Beacon LEDs for Unified Ports
Complete the following task for each module for which you want to configure beacon LEDs.
SUMMARY STEPS
1.
UCS-A# scope fabric-interconnect { a | b }
2.
UCS-A /fabric # scope card slot-id
3.
UCS-A /fabric/card # scope beacon-led
4.
UCS-A /fabric/card/beacon-led # set admin-state { eth | fc | off }
5.
UCS-A /fabric/card/beacon-led # commit-buffer
DETAILED STEPS
Step 1
Step 2
Command or Action
UCS-A# scope fabric-interconnect { a | b }
UCS-A /fabric # scope card slot-id
Step 3
Step 4
Purpose
Enters fabric interconnect mode for the specified fabric.
Enters card mode for the specified fixed or expansion module.
Enters beacon LED mode.
UCS-A /fabric/card # scope beacon-led
UCS-A /fabric/card/beacon-led # set admin-state { eth | fc | off }
Specifies which port mode is represented by illuminated beacon LED lights.
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
19
SAN Ports and Port Channels
Unified Ports on the Fabric Interconnect
Command or Action Purpose eth
All of the Unified Ports configured in Ethernet mode illuminate.
fc
All of the Unified Ports configured in Fibre Channel mode illuminate.
off
Beacon LED lights for all ports on the module are turned off.
Commits the transaction to the system configuration.
Step 5 UCS-A /fabric/card/beacon-led # commit-buffer
Example
The following example illuminates all of the beacon lights for Unified Ports in Ethernet port mode and commits the transaction:
UCS-A# scope fabric-interconnect a
UCS-A /fabric # scope card 1
UCS-A /fabric/card # scope beacon-led
UCS-A /fabric/card/beacon-led # set admin-state eth
UCS-A /fabric/card/beacon-led* # commit-buffer
UCS-A /fabric/card/beacon-led #
Unified Ports on the Fabric Interconnect
Unified ports are ports on the fabric interconnect that can be configured to carry either Ethernet or Fibre
Channel traffic. These ports are not reserved. A Cisco UCS domain cannot use these ports until you configure them.
Note When you configure a port on a fabric interconnect, the administrative state is automatically set to enabled.
If the port is connected to another device, this may cause traffic disruption. You can disable the port after configuring it.
Configurable beacon LEDs indicate which unified ports are configured for the selected port mode.
Unified Storage Ports
Unified storage involves configuring the same physical port as both an Ethernet storage interface and an FCoE storage interface. You can configure any appliance port or FCoE storage port as a unified storage port, on either a fixed module or an expansion module. To configure a unified storage port, you must have the fabric interconnect in Fibre Channel switching mode.
In a unified storage port, you can enable or disable individual FCoE storage or appliance interfaces.
20
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
SAN Ports and Port Channels
Configuring a Unified Storage Port
• In an unified storage port, if you do not specify a non-default VLAN for the appliance port, the
FCoE-storage-native-vlan will be assigned as the native VLAN on the unified storage port. If the appliance port has a non-default native VLAN specified as native VLAN, this will be assigned as the native VLAN for the unified storage port.
• When you enable or disable the appliance interface, the corresponding physical port is enabled or disabled.
So when you disable the appliance interface in unified storage, even if the FCoE storage is enabled, it goes down with the physical port.
• When you enable or disable the FCoE storage interface, the corresponding VFC is enabled or disabled.
So when the FCoE storage interface is disabled in a unified storage port, the appliance interface will continue to function normally.
Configuring a Unified Storage Port
SUMMARY STEPS
1.
UCS-A# scope eth-storage
2.
UCS-A /eth-storage # scope fabric { a | b }
3.
UCS-A /eth-storage/fabric # create interface slot-num port-num
4.
UCS-A /eth-storage/fabric/interface* # commit buffer
5.
UCS-A /eth-storage/fabric/interface* # scope fc-storage
6.
UCS-A /fc-storage* # scope fabric { a | b }
7.
UCS-A /fc-storage/fabric # create interface fcoe slot-num port-num
DETAILED STEPS
Step 1
Step 2
Command or Action
UCS-A# scope eth-storage
UCS-A /eth-storage # scope fabric { a | b }
Step 3
Step 4
Step 5
Step 6
Purpose
Enters Ethernet storage mode.
UCS-A /eth-storage/fabric # create interface slot-num port-num
UCS-A /eth-storage/fabric/interface* # commit buffer
Enters Ethernet storage mode for the specified fabric.
Creates an interface for the specified appliance port.
Commits the transaction to the system configuration.
UCS-A /eth-storage/fabric/interface* # scope fc-storage Enters FC storage mode.
Step 7
UCS-A /fc-storage* # scope fabric { a | b } Enters Ethernet storage mode for the specific appliance port.
UCS-A /fc-storage/fabric # create interface fcoe slot-num port-num
Adds FCoE storage port mode on the appliance port mode and creates a unified storage port..
Example
The following example creates an interface for an appliance port 2 on slot 3 of fabric A, adds fc storage to the same port to convert it as an unified port , and commits the transaction:
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
21
SAN Ports and Port Channels
Unified Uplink Ports
UCS-A# scope eth-storage
UCS-A /eth-storage # scope fabric a
UCS-A /eth-storage/fabric # create interface 3 2
UCS-A /eth-storage/fabric* # commit-buffer
UCS-A /eth-storage/fabric* # scope fc-storage
UCS-A /fc-storage*# scope fabric a
UCS-A /fc-storage/fabric* # create interface fcoe 3 2
UCS-A /fc-storage/fabric* # commit-buffer
UCS-A /fc-storage/fabric*
Unified Uplink Ports
When you configure an Ethernet uplink and an FCoE uplink on the same physical Ethernet port, it is called a unified uplink port. You can individually enable or disable either the FCoE or Ethernet interfaces independently.
• Enabling or disabling the FCoE uplink results in the corresponding VFC being enabled or disabled.
• Enabling or disabling an Ethernet uplink results in the corresponding physical port being enabled or disabled.
If you disable an Ethernet uplink, it disables the underlying physical port in a unified uplink. Therefore, even when the FCoE uplink is enabled, the FCoE uplink also goes down. But if you disable an FCoE uplink, only the VFC goes down. If the Ethernet uplink is enabled, it can still function properly in the unified uplink port.
Configuring a Unified Uplink Port
To configure a unified uplink port, you will convert an existing FCoE uplink port as a unified port.
SUMMARY STEPS
1.
UCS-A# scope eth-uplink
2.
UCS-A /eth-uplink # scope fabric { a | b }
3.
UCS-A /eth-uplink/fabric # create interface 15
4.
UCS-A /eth-uplink/fabric/port-channel # commit-buffer
DETAILED STEPS
Step 1
Step 2
Command or Action
UCS-A# scope eth-uplink
UCS-A /eth-uplink # scope fabric { a | b }
Step 3
Step 4
Purpose
Enters Ethernet uplink mode.
Enters Ethernet uplink fabric mode for the specified fabric.
UCS-A /eth-uplink/fabric # create interface 15 Converts the FCoE uplink port as a unified port.
UCS-A /eth-uplink/fabric/port-channel # commit-buffer Commits the transaction to the system configuration.
Example
The following example creates a unified uplink port on an existing FCoE port:
22
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
SAN Ports and Port Channels
Unified Uplink Port Channel
UCS-A# scope eth-uplink
UCS-A /eth-uplink # scope fabric b
UCS-A /eth-uplink/fabric # create interface 1 5
UCS-A /eth-uplink/fabric/interface* # commit-buffer
UCS-A /eth-uplink/interface #
Unified Uplink Port Channel
When you create an Ethernet port channel and an FCoE port channel with the same ID, it is called a unified uplink port channel. When the unified port channel is created, a physical Ethernet port channel and a VFC are created on the fabric interconnect with the specified members. The physical Ethernet port channel is used to carry both Ethernet and FCoE traffic. The VFC binds FCoE traffic to the Ethernet port channel.
The following rules will apply to the member port sets of the unified uplink port channel:
• The Ethernet port channel and FCoE port channel on the same ID, must have the same set of member ports.
• When you add a member port channel to the Ethernet port channel, Cisco UCS Manager adds the same port channel to FCoE port channel as well. Similarly, adding a member to the FCoE port channel adds the member port to the Ethernet port channel.
• When you delete a member port from one of the port channels, Cisco UCS Manager automatically deletes the member port from the other port channel.
If you disable an Ethernet uplink port channel, it disables the underlying physical port channel in a unified uplink port channel. Therefore, even when the FCoE uplink is enabled, the FCoE uplink port channel also goes down. If you disable an FCoE uplink port channel, only the VFC goes down. If the Ethernet uplink port channel is enabled, it can still function properly in the unified uplink port channel.
Configuring a Unified Uplink Port Channel
To configure a unified uplink port channel, you will convert an existing FCoE uplink port channel as a unified port channel.
SUMMARY STEPS
1.
UCS-A# scope eth-uplink
2.
UCS-A /eth-uplink # scope fabric { a | b }
3.
UCS-A /eth-uplink/fabric # create port-channel ID
4.
UCS-A /eth-uplink/fabric/port-channel # commit-buffer
DETAILED STEPS
Step 1
Step 2
Step 3
Step 4
Command or Action
UCS-A# scope eth-uplink
UCS-A /eth-uplink # scope fabric
UCS-A /eth-uplink/fabric #
{ a | b }
create port-channel ID
Purpose
Enters Ethernet uplink mode.
Enters Ethernet uplink fabric mode for the specified fabric.
Creates a port channel for the specified Ethernet uplink port.
UCS-A /eth-uplink/fabric/port-channel # commit-buffer Commits the transaction to the system configuration.
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
23
SAN Ports and Port Channels
Cisco UCS Mini Scalability Ports
Example
The following example creates a unified uplink port channel on an existing FCoE port channel:
UCS-A# scope eth-uplink
UCS-A /eth-uplink # scope fabric b
UCS-A /eth-uplink/fabric # create port-channel 2
UCS-A /eth-uplink/fabric/port-channel* # commit-buffer
UCS-A /eth-uplink/fabric #
Cisco UCS Mini Scalability Ports
The contains a scalability port as well as four unified ports. The scalability port is a 40GB QSFP+ breakout port that, with proper cabling, can support four 1G or 10G SFP+ ports. The scalability ports can be used as a licensed server port for supported Cisco UCS rack servers, an appliance port, or a FCoE port.
In the Cisco UCS Manager GUI, the scalability port is displayed as Scalability Port 5 below the Ethernet
Ports node. The individual breakout ports are displayed as Port 1 through Port 4 .
In the Cisco UCS Manager CLI, the scalability port is not displayed, but the individual breakout ports are displayed as Br-Eth1/5/1 through Br-Eth1/5/4 .
Configuring Scalability Ports
To configure ports, port channel members or SPAN members on the scalability port, scope into the scalability port first, then follow the steps for a standard unified port.
SUMMARY STEPS
1.
UCS-A# scope eth-server
2.
UCS-A /eth-server # scope fabric { a | b }
3.
UCS-A /eth-server/fabric # scope aggr-interface slot-num port-num
4.
UCS-A /eth-server/fabric/aggr-interface # show interface
5.
UCS-A /eth-server/fabric/aggr-interface # create interface slot-num port-num
6.
UCS-A /eth-server/fabric/aggr-interface # commit-buffer
DETAILED STEPS
Step 1
Step 2
Step 3
Step 4
Step 5
Command or Action
UCS-A# scope eth-server
Purpose
Enters Ethernet server mode.
UCS-A /eth-server # scope fabric { a | b } Enters Ethernet server fabric mode for the specified fabric.
UCS-A /eth-server/fabric # scope aggr-interface slot-num port-num
Enters ethernet server fabric aggregate interface mode for the scalability port.
UCS-A /eth-server/fabric/aggr-interface # show interface Displays the interfaces on the scalability port.
UCS-A /eth-server/fabric/aggr-interface # create interface slot-num port-num
Creates an interface for the specified Ethernet server port.
24
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
SAN Ports and Port Channels
Appliance Ports
Step 6
Command or Action Purpose
UCS-A /eth-server/fabric/aggr-interface # commit-buffer Commits the transaction to the system configuration.
Example
The following example shows how to create an interface for Ethernet server port 3 on the fabric A scalability port and commit the transaction:
UCS-A# scope eth-server
UCS-A /eth-server # scope fabric a
UCS-A /eth-server/fabric # scope aggr-interface 1 5
UCS-A /eth-server/fabric/aggr-interface # show interface
Interface:
Slot Id Aggr-Port ID Port Id Admin State Oper State State Reason
------- ------------ -------- ----------- ------------- ------------
1 5 1 Enabled Up
1
1
1
5
5
5
2 Enabled
3 Enabled
4 Enabled
Up
Admin Down
Admin Down
Administratively Down
Administratively Down
UCS-A /eth-server/fabric/aggr-interface # create interface 1 3
UCS-A /eth-server/fabric/aggr-interface* # commit-buffer
UCS-A /eth-server/fabric/aggr-interface #
Appliance Ports
Appliance ports are only used to connect fabric interconnects to directly attached NFS storage.
Note When you create a new appliance VLAN, its IEEE VLAN ID is not added to the LAN Cloud. Therefore, appliance ports that are configured with the new VLAN remain down, by default, due to a pinning failure.
To bring up these appliance ports, you have to configure a VLAN in the LAN Cloud with the same IEEE
VLAN ID.
Cisco UCS Manager supports up to four appliance ports per fabric interconnect.
Configuring an Appliance Port
You can configure Appliance ports on either the fixed module or an expansion module.
Step 1
Step 2
Procedure
Command or Action
UCS-A# scope eth-storage
UCS-A /eth-storage # scope fabric { a | b }
Purpose
Enters Ethernet storage mode.
Enters Ethernet storage mode for the specified fabric.
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
25
SAN Ports and Port Channels
Configuring an Appliance Port
Step 3
Step 4
Step 5
Step 6
Step 7
Step 8
Command or Action
UCS-A /eth-storage/fabric # create interface slot-num port-num
(Optional) UCS-A /eth-storage/fabric/interface # set portmode { access | trunk }
Purpose
Creates an interface for the specified appliance port.
Specifies whether the port mode is access or trunk. By default, the mode is set to trunk.
Note If traffic for the appliance port needs to traverse the uplink ports, you must also define each
VLAN used by this port in the LAN cloud. For example, you need the traffic to traverse the uplink ports if the storage is also used by other servers, or if you want to ensure that traffic fails over to the secondary fabric interconnect if the storage controller for the primary fabric interconnect fails.
(Optional) UCS-A /eth-storage/fabric/interface # set
pingroupname pin-group name
Specifies the appliance pin target to the specified fabric and port, or fabric and port channel.
(Optional) UCS-A /eth-storage/fabric/interface # set prio sys-class-name
Specifies the QoS class for the appliance port. By default, the priority is set to best-effort.
The sys-class-name argument can be one of the following class keywords:
• C —Use this priority for QoS policies that control vHBA traffic only.
• Platinum —Use this priority for QoS policies that control vNIC traffic only.
• Gold —Use this priority for QoS policies that control vNIC traffic only.
• Silver —Use this priority for QoS policies that control vNIC traffic only.
• Bronze —Use this priority for QoS policies that control vNIC traffic only.
• Best Effort —Do not use this priority. It is reserved for the Basic Ethernet traffic lane. If you assign this priority to a QoS policy and configure another system class as CoS 0, Cisco UCS Manager does not default to this system class. It defaults to the priority with CoS
0 for that traffic.
(Optional) UCS-A /eth-storage/fabric/interface # set adminspeed { 10gbps | 1 gbps }
UCS-A /eth-storage/fabric/interface # commit buffer
Specifies the admin speed for the interface. By default, the admin speed is set to 10gbps.
Commits the transaction to the system configuration.
26
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
SAN Ports and Port Channels
Assigning a Target MAC Address to an Appliance Port or Appliance Port Channel
Example
The following example creates an interface for an appliance port 2 on slot 3 of fabric B, sets the port mode to access, pins the appliance port to a pin group called pingroup1, sets the QoS class to fc, sets the admin speed to 10 gbps, and commits the transaction:
UCS-A# scope eth-storage
UCS-A /eth-storage # scope fabric b
UCS-A /eth-storage/fabric # create interface 3 2
UCS-A /eth-storage/fabric* # set portmode access
UCS-A /eth-storage/fabric* # set pingroupname pingroup1
UCS-A /eth-storage/fabric* # set prio fc
UCS-A /eth-storage/fabric* # set adminspeed 10gbps
UCS-A /eth-storage/fabric* # commit-buffer
UCS-A /eth-storage/fabric #
What to do next
Assign a VLAN or target MAC address for the appliance port.
Assigning a Target MAC Address to an Appliance Port or Appliance Port
Channel
The following procedure assigns a target MAC address to an appliance port. To assign a target MAC address to an appliance port channel, scope to the port channel instead of the interface.
SUMMARY STEPS
1.
UCS-A# scope eth-storage
2.
UCS-A /eth-storage # scope fabric { a | b }
3.
UCS-A /eth-storage/fabric # scope interface slot-id port-id
4.
UCS-A /eth-storage/fabric/interface # create eth-target eth-target name
5.
UCS-A /eth-storage/fabric/interface/eth-target # set mac-address mac-address
DETAILED STEPS
Step 1
Step 2
Command or Action
UCS-A# scope eth-storage
Step 3
Purpose
Enters Ethernet storage mode.
UCS-A /eth-storage # scope fabric { a | b } Enters Ethernet storage mode for the specified fabric.
UCS-A /eth-storage/fabric # scope interface slot-id port-id Enters Ethernet interface mode for the specified interface.
Note To assign a target MAC address to an appliance port channel, use the scope port-channel command instead of scope interface .
Step 4 UCS-A /eth-storage/fabric/interface # eth-target name create eth-target Specifies the name for the specified MAC address target.
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
27
SAN Ports and Port Channels
Creating an Appliance Port
Step 5
Command or Action
UCS-A /eth-storage/fabric/interface/eth-target # set
mac-address mac-address
Purpose
Specifies the MAC address in nn:nn:nn:nn:nn:nn format.
Example
The following example assigns a target MAC address for an appliance device on port 3, slot 2 of fabric B and commits the transaction:
UCS-A# scope eth-storage
UCS-A /eth-storage* # scope fabric b
UCS-A /eth-storage/fabric* # scope interface 2 3
UCS-A /eth-storage/fabric/interface* # create eth-target macname
UCS-A /eth-storage/fabric/interface* # set mac-address 01:23:45:67:89:ab
UCS-A /eth-storage/fabric/interface* # commit-buffer
UCS-A /eth-storage/fabric #
The following example assigns a target MAC address for appliance devices on port channel 13 of fabric B and commits the transaction:
UCS-A# scope eth-storage
UCS-A /eth-storage* # scope fabric b
UCS-A /eth-storage/fabric* # scope port-channel 13
UCS-A /eth-storage/fabric/port-channel* # create eth-target macname
UCS-A /eth-storage/fabric/port-channel* # set mac-address 01:23:45:67:89:ab
UCS-A /eth-storage/fabric/port-channel* # commit-buffer
UCS-A /eth-storage/fabric #
Creating an Appliance Port
SUMMARY STEPS
Step 3
1.
UCS-A# scope eth-storage
2.
UCS-A/eth-storage# create vlan vlan-name vlan-id
3.
UCS-A/eth-storage/vlan# set sharing primary
4.
UCS-A/eth-storage/vlan# commit buffer
5.
UCS-A/eth-storage# create vlan vlan-name vlan-id
6.
UCS-A/eth-storage/vlan# set sharing community
7.
UCS-A/eth-storage/vlan# set pubnwname primary vlan-name
8.
UCS-A/eth-storage/vlan# commit buffer
DETAILED STEPS
Step 1
Step 2
Command or Action
UCS-A# scope eth-storage
UCS-A/eth-storage# create vlan vlan-name vlan-id
UCS-A/eth-storage/vlan# set sharing primary
Purpose
Enters Ethernet storage mode.
Creates a named VLAN, specifies the VLAN name and
VLAN ID, and enters Ethernet storage VLAN mode
Saves the changes.
28
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
SAN Ports and Port Channels
Mapping an Appliance Port to a Community VLAN
Step 4
Step 5
Command or Action
UCS-A/eth-storage/vlan# commit buffer
UCS-A/eth-storage# create vlan vlan-name vlan-id
Step 6 UCS-A/eth-storage/vlan# set sharing community
Step 7
Step 8
UCS-A/eth-storage/vlan# set pubnwname primary vlan-name
UCS-A/eth-storage/vlan# commit buffer
Purpose
Commits the transaction to the system configuration.
Creates a named VLAN, specifies the VLAN name and
VLAN ID, and enters Ethernet storage VLAN mode .
Associates the primary VLAN to the secondary VLAN that you are creating.
Specifies the primary VLAN to be associated with this secondary VLAN.
Commits the transaction to the system configuration.
Example
The following example creates an appliance port:
UCS-A# scope eth-storage
UCS-A/eth-storage# create vlan PRI600 600
UCS-A/eth-storage/vlan* # set sharing primary
UCS-A/eth-storage/vlan* # commit-buffer
UCS-A/eth-storage # create vlan COM602 602
UCS-A/eth-storage/vlan* # set sharing isolated
UCS-A/eth-storage/vlan* # set pubnwname PRI600
UCS-A/eth-storage/vlan* # commit-buffer
Mapping an Appliance Port to a Community VLAN
SUMMARY STEPS
1.
UCS-A# scope eth-storage
2.
UCS-A/eth-storage# scope fabric { a | b }
3.
UCS-A/eth-storage/fabric# create interface slot-num port-num
4.
UCS-A/eth-storage/fabric/interface# exit
5.
UCS-A/eth-storage/fabric# exit
6.
UCS-A/eth-storage# scope vlan vlan-name
7.
UCS-A/eth-storage/vlan# create member-port fabric slot-num port-num
8.
UCS-A/eth-storage/vlan/member-port# commit
DETAILED STEPS
Step 1
Step 2
Command or Action
UCS-A# scope eth-storage
UCS-A/eth-storage# scope fabric { a | b }
Purpose
Enters Ethernet storage mode.
Enters Ethernet storage fabric interconnect mode for the specified fabric interconnect.
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
29
SAN Ports and Port Channels
Unconfiguring an Appliance Port
Step 3
Step 4
Step 5
Step 6
Step 7
Step 8
Command or Action
UCS-A/eth-storage/fabric# create interface slot-num port-num
UCS-A/eth-storage/fabric/interface# exit
UCS-A/eth-storage/fabric#
UCS-A/eth-storage# exit
scope vlan vlan-name
UCS-A/eth-storage/vlan# create member-port fabric slot-num port-num
UCS-A/eth-storage/vlan/member-port# commit
Purpose
Creates an interface for the specified Ethernet server port.
Exits from the interface.
Note Ensure you commit the transaction after associating with the VLAN.
Exits from the fabric.
Enters the specified VLAN.
Note Ensure community VLAN is created in the appliance cloud.
Creates the member port for the specified fabric, assigns the slot number, and port number and enters member port configuration.
Commits the transaction to the system configuration.
Example
The following example maps an appliance port to an community VLAN:
UCS-A# scope eth-storage
UCS-A/eth-storage# scope fabric a
UCS-A/eth-storage/fabric# create interface 1 22
UCS-A/eth-storage/fabric/interface*# exit
UCS-A/eth-storage/fabric*# exit
UCS-A/eth-storage*# scope vlan COM602
UCS-A/eth-storage/vlan*# create member-port a 1 22
UCS-A/eth-storage/vlan/member-port* commit
Unconfiguring an Appliance Port
SUMMARY STEPS
1.
UCS-A # scope eth-storage
2.
UCS-A /eth-storage # scope fabric { a | b }
3.
UCS-A /eth-storage/fabric # delete eth-interface slot-num port-num
4.
UCS-A /eth-storage/fabric # commit-buffer
DETAILED STEPS
Step 1
Step 2
Command or Action
UCS-A # scope eth-storage
UCS-A /eth-storage # scope fabric { a | b }
Purpose
Enters Ethernet storage mode.
Enters Ethernet storage mode for the specified fabric.
30
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
SAN Ports and Port Channels
FCoE Uplink Ports
Step 3
Step 4
Command or Action
UCS-A /eth-storage/fabric # commit-buffer
Purpose
UCS-A /eth-storage/fabric # delete eth-interface slot-num port-num
Deletes the interface for the specified appliance port.
Commits the transaction to the system configuration.
Example
The following example unconfigures appliance port 3 on slot 2 of fabric B and commits the transaction:
UCS-A# scope eth-storage
UCS-A /eth-storage # scope fabric b
UCS-A /eth-storage/fabric # delete eth-interface 2 3
UCS-A /eth-storage/fabric* # commit-buffer
UCS-A /eth-storage/fabric #
FCoE Uplink Ports
FCoE uplink ports are physical Ethernet interfaces between the fabric interconnects and the upstream Ethernet switch, used for carrying FCoE traffic. With this support the same physical Ethernet port can carry both
Ethernet traffic and Fibre Channel traffic.
FCoE uplink ports connect to upstream Ethernet switches using the FCoE protocol for Fibre Channel traffic.
This allows both the Fibre Channel traffic and Ethernet traffic to flow on the same physical Ethernet link.
Note FCoE uplinks and unified uplinks enable the multi-hop FCoE feature, by extending the unified fabric up to the distribution layer switch.
You can configure the same Ethernet port as any of the following:
• FCoE uplink port —As an FCoE uplink port for only Fibre Channel traffic.
• Uplink port —As an Ethernet port for only Ethernet traffic.
• Unified uplink port —As a unified uplink port to carry both Ethernet and Fibre Channel traffic.
Configuring a FCoE Uplink Port
All of the port types listed are configurable on both the fixed and expansion module, including server ports, which are not configurable on the 6100 series fabric interconnect expansion module, but are configurable on the 6200 series fabric interconnect expansion module.
SUMMARY STEPS
1.
UCS-A# scope fc-uplink
2.
UCS-A /fc-uplink # scope fabric { a | b }
3.
UCS-A /fc-uplink/fabric # create fcoeinterface slot-numberport-number
4.
UCS-A /fc-uplink/fabric/fabricinterface # commit-buffer
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
31
SAN Ports and Port Channels
Viewing FCoE Uplink Ports
DETAILED STEPS
Step 1
Step 2
Step 3
Step 4
Command or Action
UCS-A# scope fc-uplink
UCS-A /fc-uplink # scope fabric { a | b }
Purpose
Enters FC Uplink mode.
Enters FC - Uplink mode for the specific fabric.
UCS-A /fc-uplink/fabric # create fcoeinterface slot-numberport-number
Creates interface for the specified FCoE uplink port.
UCS-A /fc-uplink/fabric/fabricinterface # commit-buffer Commits the transaction to the system configuration.
Example
The following example creates an interface for FCoE uplink port 1 on slot 8 of fabric A and commits the transaction:
UCS-A# scope fc-uplink
UCS-A /fc-uplink # scope fabric a
UCS-A /fc-uplink/fabric # create fcoeinterface 1 8
UCS-A /fc-uplink/fabric/fcoeinterface* # commit-buffer
UCS-A /fc-uplink/fabric/fcoeinterface #
Viewing FCoE Uplink Ports
SUMMARY STEPS
1.
UCS-A# scope fc-uplink
2.
UCS-A /fc-uplink # scope fabric { a | b }
3.
UCS-A /fc-uplink/fabric # show fcoeinterface
DETAILED STEPS
Step 1
Step 2
Command or Action
UCS-A# scope fc-uplink
Step 3
UCS-A /fc-uplink # scope fabric { a | b }
UCS-A /fc-uplink/fabric # show fcoeinterface
Purpose
Enters FC Uplink mode.
Enters FC - Uplink mode for the specific fabric.
Lists the available interfaces.
Example
The following example displays the available FCoE uplink interfaces on fabric A:
UCS-A# scope fc-uplink
UCS-A /fc-uplink # scope fabric a
UCS-A /fc-uplink/fabric # show fcoeinterface
FCoE Interface:
Slot Id c State
Port Id Admin State Operational State Operational State Reason Li
Grace Prd
32
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
SAN Ports and Port Channels
Unconfiguring a FCoE Uplink Port
---------- ---------- ----------- ----------------- ------------------------- --
------------------ --------cense Ok
1 26 Enabled
0
Indeterminate Li
Fcoe Member Port:
1
1
Port-channel Slot Port Oper State State Reason
------------ ----- ----- --------------- ------------
1 1 10 Sfp Not Present Unknown
1
1
3 Sfp Not Present Unknown
4 Sfp Not Present Unknown
1
1
2
1
1
1
6 Sfp Not Present Unknown
8 Sfp Not Present Unknown
7 Sfp Not Present Unknown
UCS-A /fc-uplink/fabric #
Unconfiguring a FCoE Uplink Port
SUMMARY STEPS
1.
UCS-A# scope fc-uplink
2.
UCS-A /fc-uplink # scope fabric { a | b }
3.
UCS-A /fc-uplink/fabric # delete fcoeinterface slot-numberport-number
4.
UCS-A /fc-uplink/fabric/fabricinterface # commit-buffer
DETAILED STEPS
Step 1
Step 2
Command or Action
UCS-A# scope fc-uplink
UCS-A /fc-uplink # scope fabric { a | b }
Step 3
Step 4
Purpose
Enters FC Uplink mode.
Enters FC - Uplink mode for the specific fabric.
UCS-A /fc-uplink/fabric # delete fcoeinterface slot-numberport-number
Deletes the specified interface.
UCS-A /fc-uplink/fabric/fabricinterface # commit-buffer Commits the transaction to the system configuration.
Example
The following example deletes the FCoE uplink interface on port 1 on slot 8 of fabric A and commits the transaction:
UCS-A# scope fc-uplink
UCS-A /fc-uplink # scope fabric a
UCS-A /fc-uplink/fabric # delete fcoeinterface 1 8
UCS-A /fc-uplink/fabric/fcoeinterface* # commit-buffer
UCS-A /fc-uplink/fabric/fcoeinterface #
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
33
SAN Ports and Port Channels
FCoE and Fibre Channel Storage Ports
FCoE and Fibre Channel Storage Ports
Configuring a Fibre Channel Storage or FCoE Port
SUMMARY STEPS
1.
UCS-A# scope fc-storage
2.
UCS-A /fc-storage # scope fabric { a | b }
3.
UCS-A /fc-storage/fabric # create interface { fc | fcoe } slot-num port-num
4.
UCS-A /fc-storage/fabric # commit-buffer
DETAILED STEPS
Step 1
Step 2
Command or Action
UCS-A# scope fc-storage
Step 3
UCS-A /fc-storage # scope fabric { a | b }
UCS-A /fc-storage/fabric # create interface { fc | fcoe } slot-num port-num
Step 4 UCS-A /fc-storage/fabric # commit-buffer
Purpose
Enters Fibre Channel storage mode.
Enters Fibre Channel storage mode for the specified fabric.
Creates an interface for the specified Fibre Channel storage port.
On Cisco UCS 6454 Fabric Interconnects, ports 49-54 cannot be configured as FCoE storage ports.
Commits the transaction.
Example
The following example creates an interface for Fibre Channel storage port 10 on slot 2 of fabric A and commits the transaction:
UCS-A# scope fc-storage
UCS-A /fc-storage # scope fabric a
UCS-A /fc-storage/fabric* # create interface fc 2 10
UCS-A /fc-storage/fabric # commit-buffer
What to do next
Assign a VSAN.
Unconfiguring a Fibre Channel Storage or FCoE Port
SUMMARY STEPS
1.
UCS-A# scope fc-storage
2.
UCS-A /fc-storage # scope fabric { a | b }
3.
UCS-A /fc-storage/fabric # delete interface { fc | fcoe } slot-num port-num
34
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
SAN Ports and Port Channels
Restoring a Fibre Channel Storage Port Back to an Uplink Fibre Channel Port
4.
UCS-A /fc-storage/fabric # commit-buffer
DETAILED STEPS
Step 1
Step 2
Step 3
Step 4
Command or Action
UCS-A# scope fc-storage
UCS-A /fc-storage # scope fabric { a | b }
UCS-A /fc-storage/fabric # delete interface { fc | fcoe } slot-num port-num
UCS-A /fc-storage/fabric # commit-buffer
Purpose
Enters Fibre Channel storage mode.
Enters Fibre Channel storage mode for the specified fabric.
Deletes the interface for the specified Fibre Channel or
FCoE storage port.
Commits the transaction.
Example
The following example unconfigures Fibre Channel storage port 10 on slot 2 of fabric A and commits the transaction:
UCS-A# scope fc-storage
UCS-A /fc-storage # scope fabric a
UCS-A /fc-storage/fabric* # delete interface fc 2 10
UCS-A /fc-storage/fabric # commit-buffer
Restoring a Fibre Channel Storage Port Back to an Uplink Fibre Channel Port
SUMMARY STEPS
1.
UCS-A# scope fc-uplink
2.
UCS-A /fc-uplink # scope fabric { a | b }
3.
UCS-A /fc-uplink/fabric # create interface slot-num port-num
4.
UCS-A /fc-uplink/fabric # commit-buffer
DETAILED STEPS
Step 1
Step 2
Step 3
Step 4
Command or Action
UCS-A# scope fc-uplink
UCS-A /fc-uplink # scope fabric { a | b }
UCS-A /fc-uplink/fabric # create interface slot-num port-num
UCS-A /fc-uplink/fabric # commit-buffer
Purpose
Enters Fibre Channel uplink mode.
Enters Fibre Channel uplink mode for the specified fabric.
Creates an interface for the specified Fibre Channel uplink port.
Commits the transaction.
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
35
SAN Ports and Port Channels
Appliance Port Channels
Example
The following example creates an interface for Fibre Channel uplink port 10 on slot 2 of fabric A and commits the transaction:
UCS-A# scope fc-uplink
UCS-A /fc-uplink # scope fabric a
UCS-A /fc-uplink/fabric* # create interface 2 10
UCS-A /fc-uplink/fabric # commit-buffer
Appliance Port Channels
An appliance port channel allows you to group several physical appliance ports to create one logical Ethernet storage link for the purpose of providing fault-tolerance and high-speed connectivity. In Cisco UCS Manager, you create a port channel first and then add appliance ports to the port channel. You can add up to eight appliance ports to a port channel.
Configuring an Appliance Port Channel
SUMMARY STEPS
1.
UCS-A# scope eth-storage
2.
UCS-A /eth-storage # scope fabric { a | b }
3.
UCS-A /eth-storage/fabric # create port-channel port-num
4.
(Optional) UCS-A /eth-storage/fabric/port-channel # { enable | disable }
5.
(Optional) UCS-A /eth-storage/fabric/port-channel # set name port-chan-name
6.
(Optional) UCS-A /eth-storage/fabric/port-channel # set pingroupname pin-group name
7.
(Optional) UCS-A /eth-storage/fabric/port-channel # set portmode { access | trunk }
8.
(Optional) UCS-A /eth-storage/fabric/port-channel # set prio sys-class-name
9.
(Optional) UCS-A /eth-storage/fabric/port-channel # set speed { 1gbps | 2gbps | 4gbps | 8gbps | auto }
10.
UCS-A /eth-storage/fabric/port-channel # commit-buffer
DETAILED STEPS
Step 1
Step 2
Command or Action
UCS-A# scope eth-storage
Step 3
Step 4
Step 5
Purpose
Enters Ethernet storage mode.
UCS-A /eth-storage # scope fabric { a | b }
UCS-A /eth-storage/fabric # port-num create port-channel
(Optional) UCS-A /eth-storage/fabric/port-channel #
{ enable | disable }
Enters Ethernet storage fabric mode for the specified fabric.
Creates a port channel on the specified Ethernet storage port, and enters Ethernet storage fabric port channel mode.
Enables or disables the administrative state of the port channel. The port channel is disabled by default.
(Optional) UCS-A /eth-storage/fabric/port-channel # set name port-chan-name
Specifies the name for the port channel.
36
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
SAN Ports and Port Channels
Configuring an Appliance Port Channel
Step 6
Step 7
Step 8
Step 9
Step 10
Command or Action Purpose
(Optional) UCS-A /eth-storage/fabric/port-channel # set
pingroupname pin-group name
Specifies the appliance pin target to the specified fabric and port, or fabric and port channel.
(Optional) UCS-A /eth-storage/fabric/port-channel # set portmode { access | trunk }
Specifies whether the port mode is access or trunk. By default, the mode is set to trunk.
(Optional) UCS-A /eth-storage/fabric/port-channel # set
prio sys-class-name
Specifies the QoS class for the appliance port. By default, the priority is set to best-effort.
The sys-class-name argument can be one of the following class keywords:
• C —Use this priority for QoS policies that control vHBA traffic only.
• Platinum —Use this priority for QoS policies that control vNIC traffic only.
• Gold —Use this priority for QoS policies that control vNIC traffic only.
• Silver —Use this priority for QoS policies that control vNIC traffic only.
• Bronze —Use this priority for QoS policies that control vNIC traffic only.
• Best Effort —Do not use this priority. It is reserved for the Basic Ethernet traffic lane. If you assign this priority to a QoS policy and configure another system class as CoS 0, Cisco UCS Manager does not default to this system class. It defaults to the priority with
CoS 0 for that traffic.
(Optional) UCS-A /eth-storage/fabric/port-channel # set speed { 1gbps | 2gbps | 4gbps | 8gbps | auto }
Specifies the speed for the port channel.
UCS-A /eth-storage/fabric/port-channel # commit-buffer Commits the transaction to the system configuration.
Example
The following example creates a port channel on port 13 of fabric A and commits the transaction:
UCS-A# scope eth-storage
UCS-A /eth-storage # scope fabric a
UCS-A /eth-storage/fabric # create port-channel 13
UCS-A /eth-storage/fabric/port-channel* # enable
UCS-A /eth-storage/fabric/port-channel* # set name portchan13a
UCS-A /eth-storage/fabric/port-channel* # set pingroupname pingroup1
UCS-A /eth-storage/fabric/port-channel* # set portmode access
UCS-A /eth-storage/fabric/port-channel* # set prio fc
UCS-A /eth-storage/fabric/port-channel* # set speed 2gbps
UCS-A /eth-storage/fabric/port-channel* # commit-buffer
UCS-A /eth-storage/fabric/port-channel #
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
37
SAN Ports and Port Channels
Unconfiguring an Appliance Port Channel
Unconfiguring an Appliance Port Channel
SUMMARY STEPS
1.
UCS-A# scope eth-storage
2.
UCS-A /eth-storage # scope fabric { a | b }
3.
UCS-A /eth-storage/fabric # delete port-channel port-num
4.
UCS-A /eth-storage/fabric # commit-buffer
DETAILED STEPS
Step 1
Step 2
Step 3
Step 4
Command or Action
UCS-A# scope eth-storage
UCS-A /eth-storage # scope fabric { a | b }
UCS-A /eth-storage/fabric # delete port-channel port-num
UCS-A /eth-storage/fabric # commit-buffer
Purpose
Enters Ethernet storage mode.
Enters Ethernet storage fabric mode for the specified fabric.
Deletes the port channel from the specified Ethernet storage port.
Commits the transaction to the system configuration.
Example
The following example unconfigures the port channel on port 13 of fabric A and commits the transaction:
UCS-A# scope eth-storage
UCS-A /eth-storage # scope fabric a
UCS-A /eth-storage/fabric # delete port-channel 13
UCS-A /eth-storage/fabric* # commit-buffer
UCS-A /eth-storage/fabric #
Enabling or Disabling an Appliance Port Channel
SUMMARY STEPS
1.
UCS-A# scope eth-storage
2.
UCS-A /eth-storage # scope fabric { a | b }
3.
UCS-A /eth-storage/fabric # scope port-channel port-chan-name
4.
UCS-A /eth-storage/fabric/port-channel # { enable | disable }
5.
UCS-A /eth-storage/fabric/port-channel # commit-buffer
DETAILED STEPS
Step 1
Command or Action
UCS-A# scope eth-storage
Purpose
Enters Ethernet storage mode.
38
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
SAN Ports and Port Channels
Adding a Member Port to an Appliance Port Channel
Step 2
Step 3
Step 4
Step 5
Command or Action
UCS-A /eth-storage # scope fabric { a | b }
Purpose
Enters Ethernet storage mode for the specified fabric.
UCS-A /eth-storage/fabric # scope port-channel port-chan-name
Enters Ethernet storage port channel mode.
UCS-A /eth-storage/fabric/port-channel # { enable | disable
}
Enables or disables the administrative state of the port channel. The port channel is disabled by default.
UCS-A /eth-storage/fabric/port-channel # commit-buffer Commits the transaction to the system configuration.
Example
The following example enables port channel 13 on fabric A and commits the transaction:
UCS-A# scope eth-storage
UCS-A /eth-storage # scope fabric a
UCS-A /eth-storage/fabric # scope port-channel 13
UCS-A /eth-storage/fabric/port-channel* # enable
UCS-A /eth-storage/fabric/port-channel* # commit-buffer
UCS-A /eth-storage/fabric/port-channel #
Adding a Member Port to an Appliance Port Channel
SUMMARY STEPS
1.
UCS-A# scope eth-storage
2.
UCS-A /eth-storage # scope fabric { a | b }
3.
UCS-A /eth-storage/fabric # scope port-channel port-num
4.
UCS-A /eth-storage/fabric/port-channel # create member-port slot-num port-num
5.
UCS-A /eth-storage/fabric/port-channel # commit-buffer
DETAILED STEPS
Step 1
Step 2
Command or Action
UCS-A# scope eth-storage
Step 3
Step 4
Step 5
Purpose
Enters Ethernet storage mode.
UCS-A /eth-storage # scope fabric { a | b }
UCS-A /eth-storage/fabric # scope port-channel port-num
UCS-A /eth-storage/fabric/port-channel # member-port slot-num port-num create
Enters Ethernet storage fabric mode for the specified fabric.
Enters Ethernet storage fabric port channel mode for the specified port channel.
Creates the specified member port from the port channel and enters Ethernet storage fabric port channel member port mode.
UCS-A /eth-storage/fabric/port-channel # commit-buffer Commits the transaction to the system configuration.
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
39
SAN Ports and Port Channels
Deleting a Member Port from an Appliance Port Channel
Example
The following example adds the member port on slot 1, port 7 to the port channel on port 13 of fabric
A and commits the transaction.
UCS-A# scope eth-storage
UCS-A /eth-storage # scope fabric a
UCS-A /eth-storage/fabric # scope port-channel 13
UCS-A /eth-storage/fabric/port-channel # create member-port 1 7
UCS-A /eth-storage/fabric/port-channel* # commit-buffer
UCS-A /eth-storage/fabric/port-channel #
Deleting a Member Port from an Appliance Port Channel
SUMMARY STEPS
1.
UCS-A# scope eth-storage
2.
UCS-A /eth-storage # scope fabric { a | b }
3.
UCS-A /eth-storage/fabric # scope port-channel port-num
4.
UCS-A /eth-storage/fabric/port-channel # delete member-port slot-num port-num
5.
UCS-A /eth-storage/fabric/port-channel # commit-buffer
DETAILED STEPS
Step 1
Step 2
Step 3
Step 4
Step 5
Command or Action
UCS-A# scope eth-storage
UCS-A /eth-storage # port-num scope fabric { a | b }
UCS-A /eth-storage/fabric # scope port-channel
Purpose
Enters Ethernet storage mode.
Enters Ethernet storage fabric mode for the specified fabric.
Enters Ethernet storage fabric port channel mode for the specified port channel.
UCS-A /eth-storage/fabric/port-channel # delete member-port slot-num port-num
Deletes the specified member port from the port channel.
UCS-A /eth-storage/fabric/port-channel # commit-buffer Commits the transaction to the system configuration.
Example
The following example deletes a member port from the port channel on port 13 of fabric A and commits the transaction:
UCS-A# scope eth-storage
UCS-A /eth-storage # scope fabric a
UCS-A /eth-storage/fabric # scope port-channel 13
UCS-A /eth-storage/fabric/port-channel # delete member-port 1 7
UCS-A /eth-storage/fabric/port-channel* # commit-buffer
UCS-A /eth-storage/fabric/port-channel #
40
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
SAN Ports and Port Channels
Fibre Channel Port Channels
Fibre Channel Port Channels
A Fibre Channel port channel allows you to group several physical Fibre Channel ports (link aggregation) to create one logical Fibre Channel link to provide fault-tolerance and high-speed connectivity. In Cisco UCS
Manager, you create a port channel first and then add Fibre Channel ports to the port channel.
Note Fibre Channel port channels are not compatible with non-Cisco technology.
You can create up to four Fibre Channel port channels in each Cisco UCS domain with Cisco UCS 6200,
6300, and Cisco UCS 6454 Fabric Interconnect Series fabric interconnects. Each Fibre Channel port channel can include a maximum of 16 uplink Fibre Channel ports.
You can create up to two Fibre Channel port channels in each Cisco UCS domain with Cisco UCS 6324 fabric interconnects. Each Fibre Channel port channel can include a maximum of four uplink Fibre Channel ports.
Ensure that the Fibre Channel port channel on the upstream NPIV switch is configured with its channel mode as active . If both the member port(s) and peer port(s) do not have the same channel mode configured, the port channel will not come up. When the channel mode is configured as active , the member ports initiate port channel protocol negotiation with the peer port(s) regardless of the channel group mode of the peer port. If the peer port, while configured in a channel group, does not support the port channel protocol, or responds with a nonnegotiable status, it defaults to the On mode behavior. The active port channel mode allows automatic recovery without explicitly enabling and disabling the port channel member ports at either end.
This example shows how to configure channel mode as active: switch(config)# int po114 switch(config-if)# channel mode active
Configuring a Fibre Channel Port Channel
Note If you are connecting two Fibre Channel port channels, the admin speed for both port channels must match for the link to operate. If the admin speed for one or both of the Fibre Channel port channels is set to auto,
Cisco UCS adjusts the admin speed automatically.
SUMMARY STEPS
1.
UCS-A# scope fc-uplink
2.
UCS-A /fc-uplink # scope fabric { a | b }
3.
UCS-A /fc-uplink/fabric # create port-channel port-num
4.
(Optional) UCS-A /fc-uplink/fabric/port-channel # { enable | disable }
5.
(Optional) UCS-A /fc-uplink/fabric/port-channel # set name port-chan-name
6.
(Optional) UCS-A /fc-uplink/fabric/port-channel # set speed { 1gbps | 2gbps | 4gbps | 8gbps | auto }
7.
UCS-A /fc-uplink/fabric/port-channel # commit-buffer
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
41
SAN Ports and Port Channels
Unconfiguring a Fibre Channel Port Channel
DETAILED STEPS
Step 1
Step 2
Step 3
Step 4
Step 5
Step 6
Step 7
Command or Action
UCS-A# port-num scope fc-uplink
UCS-A /fc-uplink # scope fabric
UCS-A /fc-uplink/fabric #
{ a | b } create port-channel
Purpose
Enters Fibre Channel uplink mode.
Enters Fibre Channel uplink fabric mode for the specified fabric.
Creates a port channel on the specified Fibre Channel uplink port, and enters Fibre Channel uplink fabric port channel mode.
(Optional) UCS-A /fc-uplink/fabric/port-channel # { enable
| disable }
Enables or disables the administrative state of the port channel. The port channel is disabled by default.
Specifies the name for the port channel.
(Optional) UCS-A /fc-uplink/fabric/port-channel # set name port-chan-name
(Optional) UCS-A /fc-uplink/fabric/port-channel # set speed { 1gbps | 2gbps | 4gbps | 8gbps | auto }
UCS-A /fc-uplink/fabric/port-channel # commit-buffer
Specifies the speed for the port channel.
Commits the transaction to the system configuration.
Example
The following example creates port channel 13 on fabric A, sets the name to portchan13a, enables the administrative state, sets the speed to 2 Gbps, and commits the transaction:
UCS-A# scope fc-uplink
UCS-A /fc-uplink # scope fabric a
UCS-A /fc-uplink/fabric # create port-channel 13
UCS-A /fc-uplink/fabric/port-channel* # enable
UCS-A /fc-uplink/fabric/port-channel* # set name portchan13a
UCS-A /fc-uplink/fabric/port-channel* # set speed 2gbps
UCS-A /fc-uplink/fabric/port-channel* # commit-buffer
UCS-A /fc-uplink/fabric/port-channel #
Unconfiguring a Fibre Channel Port Channel
SUMMARY STEPS
1.
UCS-A# scope fc-uplink
2.
UCS-A /fc-uplink # scope fabric { a | b }
3.
UCS-A /fc-uplink/fabric # delete port-channel port-num
4.
UCS-A /fc-uplink/fabric # commit-buffer
DETAILED STEPS
Step 1
Command or Action
UCS-A# scope fc-uplink
Purpose
Enters Fibre Channel uplink mode.
42
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
SAN Ports and Port Channels
Adding Channel Mode Active To The Upstream NPIV Fibre Channel Port Channel
Step 2
Step 3
Step 4
Command or Action
UCS-A /fc-uplink # scope fabric { a | b }
Purpose
Enters Fibre Channel uplink fabric mode for the specified fabric.
UCS-A /fc-uplink/fabric # delete port-channel port-num Deletes the port channel on the specified Fibre Channel uplink port.
UCS-A /fc-uplink/fabric # commit-buffer Commits the transaction to the system configuration.
Example
The following example unconfigures port channel 13 on fabric A and commits the transaction:
UCS-A# scope fc-uplink
UCS-A /fc-uplink # scope fabric a
UCS-A /fc-uplink/fabric # delete port-channel 13
UCS-A /fc-uplink/fabric* # commit-buffer
UCS-A /fc-uplink/fabric #
Adding Channel Mode Active To The Upstream NPIV Fibre Channel Port
Channel
SUMMARY STEPS
1.
UCS-A# scope fc-uplink
2.
UCS-A /fc-uplink # scope fabric { a | b }
3.
UCS-A /fc-uplink/fabric # create port-channel port-num
4.
(Optional) UCS-A /fc-uplink/fabric/port-channel # { enable | disable }
5.
(Optional) UCS-A /fc-uplink/fabric/port-channel # set name port-chan-name
6.
(Optional) UCS-A /fc-uplink/fabric/port-channel # scope port-chan-name
7.
(Optional) UCS-A /fc-uplink/fabric/port-channel # channel mode { active }
8.
UCS-A /fc-uplink/fabric/port-channel # commit-buffer
DETAILED STEPS
Step 1
Step 2
Step 3
Step 4
Command or Action
UCS-A# scope fc-uplink
UCS-A /fc-uplink # scope fabric { a | b }
Purpose
Enters Fibre Channel uplink mode.
Enters Fibre Channel uplink fabric mode for the specified fabric.
UCS-A /fc-uplink/fabric # port-num create port-channel Creates a port channel on the specified Fibre Channel uplink port, and enters Fibre Channel uplink fabric port channel mode.
(Optional) UCS-A /fc-uplink/fabric/port-channel # { enable
| disable }
Enables or disables the administrative state of the port channel. The port channel is disabled by default.
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
43
SAN Ports and Port Channels
Enabling or Disabling a Fibre Channel Port Channel
Step 5
Step 6
Step 7
Step 8
Command or Action
(Optional) UCS-A /fc-uplink/fabric/port-channel # set name port-chan-name
Purpose
Specifies the name for the port channel.
(Optional) UCS-A /fc-uplink/fabric/port-channel # scope port-chan-name
Specifies the name for the port channel.
(Optional) UCS-A /fc-uplink/fabric/port-channel # channel mode { active }
Configures the channel-mode active on the upstream NPIV switch.
UCS-A /fc-uplink/fabric/port-channel # commit-buffer Commits the transaction to the system configuration.
Example
The following example enables channel mode to active:
UCS-A# scope fc-uplink
UCS-A /fc-uplink # scope fabric a
UCS-A /fc-uplink/fabric # create port-channel 13
UCS-A /fc-uplink/fabric/port-channel* # enable
UCS-A /fc-uplink/fabric/port-channel* # set name portchan13a
UCS-A /fc-uplink/fabric/port-channel* # channel mode active
UCS-A /fc-uplink/fabric/port-channel* # commit-buffer
UCS-A /fc-uplink/fabric/port-channel # exit
UCS-A /fc-uplink/fabric/ # show port-channel database portchan13a
Administrative channel mode is active
Operational channel mode is active
UCS-A /fc-uplink/fabric/ #
Enabling or Disabling a Fibre Channel Port Channel
SUMMARY STEPS
1.
UCS-A# scope fc-uplink
2.
UCS-A /fc-uplink # scope fabric { a | b }
3.
UCS-A /fc-uplink/fabric # scope port-channel port-chan-name
4.
UCS-A /fc-uplink/fabric/port-channel # { enable | disable }
DETAILED STEPS
Step 1
Step 2
Command or Action
UCS-A# scope fc-uplink
Step 3
UCS-A /fc-uplink # scope fabric { a | b }
UCS-A /fc-uplink/fabric # scope port-channel port-chan-name
Purpose
Enters Fibre Channel uplink mode.
Enters Fibre Channel uplink mode for the specified fabric.
Enters Fibre Channel uplink port channel mode.
44
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
SAN Ports and Port Channels
Adding a Member Port to a Fibre Channel Port Channel
Step 4
Command or Action Purpose
UCS-A /fc-uplink/fabric/port-channel # { enable | disable
}
Enables or disables the administrative state of the port channel. The port channel is disabled by default.
Example
The following example enables port channel 13 on fabric A and commits the transaction:
UCS-A# scope fc-uplink
UCS-A /fc-uplink # scope fabric a
UCS-A /fc-uplink/fabric # scope port-channel 13
UCS-A /fc-uplink/fabric/port-channel* # enable
UCS-A /fc-uplink/fabric/port-channel* # commit-buffer
UCS-A /fc-uplink/fabric/port-channel #
Adding a Member Port to a Fibre Channel Port Channel
SUMMARY STEPS
1.
UCS-A# scope fc-uplink
2.
UCS-A /fc-uplink # scope fabric { a | b }
3.
UCS-A /fc-uplink/fabric # scope port-channel port-num
4.
UCS-A /fc-uplink/fabric/port-channel # create member-port slot-num port-num
5.
UCS-A /fc-uplink/fabric/port-channel # commit-buffer
DETAILED STEPS
Step 1
Step 2
Step 3
Step 4
Step 5
Command or Action
UCS-A# scope fc-uplink
Purpose
Enters Fibre Channel uplink mode.
UCS-A /fc-uplink # scope fabric { a | b } Enters Fibre Channel uplink fabric mode for the specified fabric.
UCS-A /fc-uplink/fabric # scope port-channel port-num Enters Fibre Channel uplink fabric port channel mode for the specified port channel.
UCS-A /fc-uplink/fabric/port-channel # create member-port slot-num port-num
Creates the specified member port from the port channel and enters Fibre Channel uplink fabric port channel member port mode.
UCS-A /fc-uplink/fabric/port-channel # commit-buffer Commits the transaction to the system configuration.
Example
The following example adds the member port on slot 1, port 7 to port channel 13 on fabric A and commits the transaction.
UCS-A# scope fc-uplink
UCS-A /fc-uplink # scope fabric a
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
45
SAN Ports and Port Channels
Deleting a Member Port from a Fibre Channel Port Channel
UCS-A /fc-uplink/fabric # scope port-channel 13
UCS-A /fc-uplink/fabric # create member-port 1 7
UCS-A /fc-uplink/fabric/port-channel* # commit-buffer
UCS-A /fc-uplink/fabric/port-channel #
Deleting a Member Port from a Fibre Channel Port Channel
SUMMARY STEPS
1.
UCS-A# scope fc-uplink
2.
UCS-A /fc-uplink # scope fabric { a | b }
3.
UCS-A /fc-uplink/fabric # scope port-channel port-num
4.
UCS-A /fc-uplink/fabric/port-channel # delete member-port slot-num port-num
5.
UCS-A /fc-uplink/fabric/port-channel # commit-buffer
DETAILED STEPS
Step 1
Step 2
Step 3
Step 4
Step 5
Command or Action
UCS-A# scope fc-uplink
UCS-A /fc-uplink # scope fabric { a | b }
Purpose
Enters Fibre Channel uplink mode.
Enters Fibre Channel uplink fabric mode for the specified fabric.
UCS-A /fc-uplink/fabric # scope port-channel port-num Enters Fibre Channel uplink fabric port channel mode for the specified port channel.
Deletes the specified member port from the port channel.
UCS-A /fc-uplink/fabric/port-channel # delete member-port slot-num port-num
UCS-A /fc-uplink/fabric/port-channel # commit-buffer Commits the transaction to the system configuration.
Example
The following example deletes a member port from port channel 13 on fabric A and commits the transaction:
UCS-A# scope fc-uplink
UCS-A /fc-uplink # scope fabric a
UCS-A /fc-uplink/fabric # scope port-channel 13
UCS-A /fc-uplink/fabric # delete member-port 1 7
UCS-A /fc-uplink/fabric/port-channel* # commit-buffer
UCS-A /fc-uplink/fabric/port-channel #
Configuring Organizationally Unique Identifier
Cisco Fiber Channel (FC) port channels are dependent on the Organizationally Unique Identifiers (OUIs) of the devices at each end of the port channels for successful configuration. When new devices are released or
46
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
SAN Ports and Port Channels
FCoE Port Channels new OUI ranges are assigned to existing devices due to OUI pool depletion, the new OUIs need to be added to their respective OUI tables for the port channel to be configured successfully.
Adding an OUI
To establish FC port-channels with new Cisco FC devices or devices with newly assigned OUI ranges, you can manually add OUIs into the database using the following command through Cisco UCSM CLI:
FI-A # sc fabric-interconnect {a|b}
FI-A /fabric-interconnect # sc oui-pool default
FI-A /fabric-interconnect/oui-pool # sh oui
FI-A /fabric-interconnect/oui-pool # create oui [oui-id]
FI-A /fabric-interconnect/oui-pool/oui* # commit-buffer
Where, oui-id is the new OUI of the device that needs to be added. The device OUI must be an eight digit hexadecimal number. The valid range of OUI is from 0x000000 to 0xffffff. For example, 0xabcdef.
Viewing OUIs
To view the list of OUIs, run the following command:
FI-A /fabric-interconnect/oui-pool# show oui
The following example shows the sample output of the show oui command:
FI-A /fabric-interconnect/oui-pool# show oui
OUI Entry:
Oui
---
0x0001ac
0x1b0000
0xaabbcc
0xddeeff
Deleting an OUI
To delete an OUI, run the following command:
FI-A /fabric-interconnect/oui-pool# delete ouientry [oui-id]
Where, oui-id is the OUI of the device that needs to be deleted.
FCoE Port Channels
An FCoE port channel allows you to group several physical FCoE ports to create one logical FCoE port channel. At a physical level, the FCoE port channel carries FCoE traffic over an Ethernet port channel. So an
FCoE port channel with a set of members is essentially an Ethernet port channel with the same members. This
Ethernet port channel is used as a physical transport for FCoE traffic.
For each FCoE port channel, Cisco UCS Manager creates a VFC internally and binds it to an Ethernet port channel. FCoE traffic received from the hosts is sent over the VFC the same way as the FCoE traffic is sent over Fibre Channel uplinks.
Configuring a FCoE Port Channel
SUMMARY STEPS
1.
UCS-A# scope fc-uplink
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
47
SAN Ports and Port Channels
Adding a Member Port to a FCoE Uplink Port Channel
2.
UCS-A /fc-uplink # scope fabric { a | b }
3.
UCS-A /fc-uplink/fabric # create fcoe-port-channel number
4.
UCS-A /fc-uplink/fabric/fabricinterface # commit-buffer
DETAILED STEPS
Step 1
Step 2
Command or Action
UCS-A# scope fc-uplink
UCS-A /fc-uplink # scope fabric { a | b }
Step 3
Step 4
Purpose
Enters FC Uplink mode.
Enters FC - Uplink mode for the specific fabric.
UCS-A /fc-uplink/fabric # create fcoe-port-channel number
Creates port channel for the specified FCoE uplink port.
UCS-A /fc-uplink/fabric/fabricinterface # commit-buffer Commits the transaction to the system configuration.
Example
The following example creates an interface for FCoE uplink port 1 on slot 4 of fabric A and commits the transaction:
UCS-A# scope fc-uplink
UCS-A /fc-uplink # scope fabric a
UCS-A /fc-uplink/fabric # create fcoe-port-channel 4
UCS-A /fc-uplink/fabric/fcoe-port-channel* # commit-buffer
UCS-A /fc-uplink/fabric/fcoe-port-channel #
Adding a Member Port to a FCoE Uplink Port Channel
SUMMARY STEPS
1.
UCS-A# scope fc-uplink
2.
UCS-A /fc-uplink # scope fabric { a | b }
3.
UCS-A /fc-uplink/fabric # scope fcoe-port-channel ID
4.
UCS-A /fc-uplink/fabric/fcoe-port-channel # create member-port slot-num port-num
5.
UCS-A /fc-uplink/fabric/fcoe-port-channel # commit-buffer
DETAILED STEPS
Step 1
Step 2
Step 3
Command or Action
UCS-A# scope fc-uplink
Purpose
Enters Fibre Channel uplink mode.
UCS-A /fc-uplink # scope fabric { a | b } Enters Fibre Channel uplink fabric mode for the specified fabric.
UCS-A /fc-uplink/fabric # scope fcoe-port-channel ID Enters FCoE uplink port channel mode for the specified port channel.
48
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
SAN Ports and Port Channels
Adapter Port Channels
Step 4
Command or Action
UCS-A /fc-uplink/fabric/fcoe-port-channel # create member-port slot-num port-num
Step 5 UCS-A /fc-uplink/fabric/fcoe-port-channel # commit-buffer
Purpose
Creates the specified member port from the port channel and enters FCoE uplink fabric port channel member port mode.
Note If the FCoE uplink port channel is a unified uplink port channel, you will get the following message:
Warning: if this is a unified port channel then member will be added to the ethernet port channel of the same id as well.
Commits the transaction to the system configuration.
Example
The following example adds the member port on slot 1, port 7 to FCoE port channel 13 on fabric A and commits the transaction.
UCS-A# scope fc-uplink
UCS-A /fc-uplink # scope fabric a
UCS-A /fc-uplink/fabric # scope fcoe-port-channel 13
UCS-A /fc-uplink/fabric # create member-port 1 7
UCS-A /fc-uplink/fabric/fcoe-port-channel* # commit-buffer
UCS-A /fc-uplink/fabric/fcoe-port-channel #
Adapter Port Channels
An adapter port channel groups into one logical link all the physical links going from a Cisco UCS Virtual
Interface Card (VIC) into an I/O.
Adapter port channels are created and managed internally by Cisco UCS Manager when it detects that the correct hardware is present. Adapter port channels cannot be configured manually. Adapter port channels are viewable using the Cisco UCS Manager GUI or the Cisco UCS Manager CLI.
Viewing Adapter Port Channels
SUMMARY STEPS
1.
UCS-A# scope chassis chassis-num
2.
UCS-A /chassis # scope iom { a b }
3.
UCS-A /chassis/iom # scope port group
4.
UCS-A /chassis/iom/port group # show host-port-channel [ detail | expand ]
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
49
SAN Ports and Port Channels
Event Detection and Action
DETAILED STEPS
Step 1
Step 2
Step 3
Step 4
Command or Action
UCS-A# scope chassis chassis-num
UCS-A /chassis #
UCS-A /chassis/iom # scope port group
UCS-A /chassis/iom/port group #
[ detail | expand ] scope iom { a b } show host-port-channel
Purpose
Enters chassis mode for the specified chassis.
Enters chassis IOM mode for the specified IOM.
Enters port group mode for the specified port group.
Displays the adapter port channels on the specified chassis.
Example
This following example shows how to display information on host port channels within a port group mode:
UCS-A # scope chassis 1
UCS-A /chassis # scope iom a
UCS-A /chassis/iom # scope port group
UCS-A /chassis/iom/port group # show host-port-channel
Host Port channel:
Port Channel Id Fabric ID Oper State State Reason
--------------- --------- ---------------- ------------
1289 B Up
1290 B
1306 B
1307 B
1309 B
1315 B
Up
Up
Up
Up
Up
UCS-A /chassis/iom/port group #
Event Detection and Action
Cisco UCS Manager uses the statistics collection policy to monitor and trigger an alarm when there are faults in the network interface ports connected from the I/O module (IOM) to the fabric interconnect.
The error statistics for the network interface ports is called NiErrStats and consists of the following errors:
NiErrStats Error Name frameTx tooLong tooShort
Crc
Description
Collects the TX_FRM_ERROR counter values.
Collects the RX_TOOLONG counter values.
Collects the sum of RX_UNDERSIZE and
RX_FRAGMENT counter values.
Collects the sum of RX_CRERR_NOT_STOMPED and RX_CRCERR_STOMPED counter values.
50
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
SAN Ports and Port Channels
Policy-Based Port Error Handling
NiErrStats Error Name inRange
Description
Collects the RX_INRANGEERR counter values.
Note The network interface port statistics is collected only from active ports and the information is sent to Cisco
UCS Manager.
Policy-Based Port Error Handling
If Cisco UCS Manager detects any errors on active NI ports, and if the error-disable feature is enabled, Cisco
UCS Manager automatically disables the respective FI port that is connected to the NI port that had errors.
When a FI port is error disabled, it is effectively shut down and no traffic is sent or received on that port.
The error-disable function serves two purposes:
• It lets you know which FI port is error-disabled and that the connected NI Port has errors.
• It eliminates the possibility that this port can cause other ports, which are connected to the same
Chassis/FEX, to fail. Such a failure can occur when the NI port has errors, which can ultimately cause serious network issues. The error-disable function helps prevent these situations.
Creating Threshold Definition
SUMMARY STEPS
1.
UCS-A # scope eth-server
2.
UCS-A/eth-server # scope stats-threshold-policy default
3.
UCSA/eth-server/stats-threshold-policy # create class class-name
4.
UCS-A/eth-server/stats-threshold-policy/class # create property property-name
5.
UCS-A/eth-server/stats-threshold-policy/class/property # set normal-value value
6.
UCS-A/eth-server/stats-threshold-policy/class/property # create threshold-value { above-normal | below-normal } { cleared | condition | critical | info | major | minor | warning }
7.
UCS-A/eth-server/stats-threshold-policy/class/property/threshold-value # set { deescalating | escalating } value
8.
UCS-A/eth-server/stats-threshold-policy/class/property/threshold-value # commit-buffer
DETAILED STEPS
Step 1
Step 2
Command or Action
UCS-A # scope eth-server
Step 3
Purpose
Enters Ethernet storage mode.
UCS-A/eth-server # scope stats-threshold-policy default Enters statistics threshold policy mode.
UCSA/eth-server/stats-threshold-policy # create class class-name
Creates the specified statistics threshold policy class and enters the organization statistics threshold policy class mode.
To see a list of the available class name keywords, enter
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
51
SAN Ports and Port Channels
Creating Threshold Definition
Step 4
Step 5
Step 6
Step 7
Step 8
Command or Action Purpose the create class ?
command in organization threshold policy mode.
UCS-A/eth-server/stats-threshold-policy/class #
property property-name create Creates the specified statistics threshold policy class property and enters the organization statistics threshold policy class property mode. To see a list of the available property name keywords, enter the create property ?
command in organization threshold policy class mode.
UCS-A/eth-server/stats-threshold-policy/class/property #
set normal-value value
Specifies the normal value for the class property. The value format can vary depending on the class property being configured. To see the required format, enter the set normal-value ?
command in organization statistics threshold policy class property mode.
UCS-A/eth-server/stats-threshold-policy/class/property # create threshold-value { above-normal | below-normal }
{ cleared | condition | critical | info | major | minor | warning }
Creates the specified threshold value for the class property and enters the organization statistics threshold policy class property threshold value mode.
UCS-A/eth-server/stats-threshold-policy/class/property/threshold-value
# set { deescalating | escalating } value
Specifies the deescalating and escalating class property threshold value. The value format can vary depending on the class property threshold value being configured. To see the required format, enter the set deescalating ?
or set escalating ?
command in the organization statistics threshold policy class property threshold value mode.
UCS-A/eth-server/stats-threshold-policy/class/property/threshold-value
# commit-buffer
Commits the transaction to the system configuration.
Example
The following example shows how to create a threshold definition:
UCS-A # scope eth-server
UCS-A /eth-server # scope stats-threshold-policy default
UCS-A /eth-server/stats-threshold-policy # create class ni-ether-error-stats
UCS-A /eth-server/stats-threshold-policy/class* # create property crc-delta
UCS-A /eth-server/stats-threshold-policy/class/property* # set normal-value 0
UCS-A /eth-server/stats-threshold-policy/class/property* # create threshold-value above-normal major
UCS-A /eth-server/stats-threshold-policy/class/property/threshold-value* # set escalating
5
UCS-A /eth-server/stats-threshold-policy/class/property/threshold-value* # set deescalating
3
UCS-A /eth-server/stats-threshold-policy/class/property/threshold-value* # commit-buffer
52
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
SAN Ports and Port Channels
Configuring Error Disable on a Fabric Interconnect Port
Configuring Error Disable on a Fabric Interconnect Port
SUMMARY STEPS
1.
UCS-A # scope eth-server
2.
UCS-A/eth-server # scope stats-threshold-policy default
3.
UCSA/eth-server/stats-threshold-policy # scope class class-name
4.
UCS-A/eth-server/stats-threshold-policy/class # scope property property-name
5.
UCS-A/eth-server/stats-threshold-policy/class/property # set error-disable-fi-port { yes | no }
6.
UCS-A/eth-server/stats-threshold-policy/class/property* # commit-buffer
DETAILED STEPS
Step 1
Step 2
Command or Action
UCS-A # scope eth-server
Purpose
Enters Ethernet storage mode.
UCS-A/eth-server # scope stats-threshold-policy default Enters statistics threshold policy mode.
Step 3
Step 4
Step 5
UCSA/eth-server/stats-threshold-policy # class-name
property property-name scope class
UCS-A/eth-server/stats-threshold-policy/class # scope
Enters the organization statistics threshold policy class mode for the specified statistics threshold policy class.
Enters the organization statistics threshold policy class property mode for the specified statistics threshold policy class property.
UCS-A/eth-server/stats-threshold-policy/class/property # set error-disable-fi-port { yes | no }
Specifies the error disable state for the class property.
Use the no option to disable error disable for the class property.
Step 6 UCS-A/eth-server/stats-threshold-policy/class/property* # commit-buffer
Commits the transaction to the system configuration.
Example
The following example shows how to enable error disable on an FI port:
UCS-A # scope eth-server
UCS-A /eth-server # scope stats-threshold-policy default
UCS-A /eth-server/stats-threshold-policy # scope class ni-ether-error-stats
UCS-A /eth-server/stats-threshold-policy/class # scope property crc-delta
UCS-A /eth-server/stats-threshold-policy/class/property # set error-disable-fi-port yes
UCS-A /eth-server/stats-threshold-policy/class/property* # commit-buffer
Configuring Auto Recovery on a Fabric Interconnect Port
SUMMARY STEPS
1.
UCS-A # scope eth-server
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
53
SAN Ports and Port Channels
Configuring Auto Recovery on a Fabric Interconnect Port
2.
UCS-A/eth-server # scope stats-threshold-policy default
3.
UCSA/eth-server/stats-threshold-policy # scope class class-name
4.
UCS-A/eth-server/stats-threshold-policy/class # scope property property-name
5.
UCS-A/eth-server/stats-threshold-policy/class/property # set auto-recovery { enabled | disabled }
6.
UCS-A/eth-server/stats-threshold-policy/class/property* # set auto-recovery-time time
7.
UCS-A/eth-server/stats-threshold-policy/class/property* # commit-buffer
DETAILED STEPS
Step 1
Step 2
Command or Action
UCS-A # scope eth-server
UCS-A/eth-server # scope stats-threshold-policy default
Purpose
Enters Ethernet storage mode.
Enters statistics threshold policy mode.
Step 3
Step 4
Step 5
UCSA/eth-server/stats-threshold-policy # class-name
property property-name scope class
UCS-A/eth-server/stats-threshold-policy/class # scope
Enters the organization statistics threshold policy class mode for the specified statistics threshold policy class.
Enters the organization statistics threshold policy class property mode for the specified statistics threshold policy class property.
UCS-A/eth-server/stats-threshold-policy/class/property # set auto-recovery { enabled | disabled }
Specifies the auto recovery state for the class property.
Use the disabled option to disable auto recovery for the class property.
Step 6
Step 7
UCS-A/eth-server/stats-threshold-policy/class/property* #
set auto-recovery-time time
Specifies the time in minutes after which the port is automatically re-enabled. The auto recovery time can range from 0 minutes to 4294967295 minutes.
UCS-A/eth-server/stats-threshold-policy/class/property* # commit-buffer
Commits the transaction to the system configuration.
Example
The following example shows how to configure auto recovery on an FI port:
UCS-A # scope eth-server
UCS-A /eth-server # scope stats-threshold-policy default
UCS-A /eth-server/stats-threshold-policy # scope class ni-ether-error-stats
UCS-A /eth-server/stats-threshold-policy/class # scope property crc-delta
UCS-A /eth-server/stats-threshold-policy/class/property # set auto-recovery enabled
UCS-A /eth-server/stats-threshold-policy/class/property* # set auto-recovery-time 5
UCS-A /eth-server/stats-threshold-policy/class/property* # commit-buffer
54
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
SAN Ports and Port Channels
Viewing the Network Interface Port Error Counters
Viewing the Network Interface Port Error Counters
SUMMARY STEPS
1.
UCS-A # scope chassis chassis-num
2.
UCS-A/chassis # scope iom { a | b }
3.
UCS-A/chassis/iom # scope port-group fabric
4.
UCS-A/chassis/iom/port-group # scope fabric-if fabric-if number
5.
UCS-A/chassis/iom/port-group/fabric-if # show stats
DETAILED STEPS
Step 1
Step 2
Step 3
Step 4
Step 5
Command or Action
UCS-A # scope chassis chassis-num
UCS-A/chassis # scope iom
UCS-A/chassis/iom #
{ a | b } scope port-group fabric
Purpose
Enters chassis mode for the specified chassis.
Enters chassis IOM mode for the specified IOM.
Enters the network interface port.
UCS-A/chassis/iom/port-group # scope fabric-if fabric-if number
Enters the specified network interface port number.
UCS-A/chassis/iom/port-group/fabric-if # show stats Displays the error counters for the network interface port.
Example
The following example shows how to display the statistics for the network interface ports:
UCS-A # scope chassis 1
UCS-A/chassis # scope iom a
UCS-A/chassis/iom # scope port-group fabric
UCS-A/chassis/iom/port-group # scope faric-if 1
UCS-A/chassis/iom/port-group/fabric-if # show stats
NI Ether Error Stats:
Time Collected: 2014-08-20T15:37:24:688
Monitored Object: sys/chassis-1/slot-1/fabric/port-1/ni-err-stats
Suspect: Yes
Crc (errors): 5000
Frame Tx (errors): 0
Too Long (errors): 0
Too Short (errors): 0
In Range (errors): 0
Thresholded: 0
Fabric Port Channels
Fabric port channels allow you to group several of the physical links from an IOM to a fabric interconnect into one logical link for redundancy and bandwidth sharing. As long as one link in the fabric port channel remains active, the fabric port channel continues to operate.
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
55
SAN Ports and Port Channels
Load Balancing Over Ports
If the correct hardware is connected, fabric port channels are created by Cisco UCS Manager in the following ways:
• During chassis discovery according to the settings configured in the chassis discovery policy.
• After chassis discovery according to the settings configured in the chassis connectivity policy for a specific chassis.
For each IOM there is a single fabric port channel. Each uplink connecting an IOM to a fabric interconnect can be configured as a discrete link or included in the port channel, but an uplink cannot belong to more than one fabric port channel. For example, if a chassis with two IOMs is discovered and the chassis discovery policy is configured to create fabric port channels, Cisco UCS Manager creates two separate fabric port channels: one for the uplinks connecting IOM-1 and another for the uplinks connecting IOM-2. No other chassis can join these fabric port channels. Similarly, uplinks belonging to the fabric port channel for IOM-1 cannot join the fabric port channel for IOM-2.
Load Balancing Over Ports
Load balancing traffic among ports between IOMs and fabric interconnects uses the following criteria for hashing.
• For Ethernet traffic:
Layer 2 source and destination address
Layer 3 source and destination address
Layer 4 source and destination ports
• For FCoE traffic:
Layer 2 source and destination address
Source and destination IDs (SID and DID) and Originator Exchange ID (OXID)
In this example, a 2200 Series IOM module is verified by connecting iom X (where X is the chassis number).
show platform software fwmctrl nifport
(....)
Hash Parameters: l2_da: 1 l2_sa: 1 l2_vlan: 0 l3_da: 1 l3_sa: 1 l4_da: 1 l4_sa: 1
FCoE l2_da: 1 l2_sa: 1 l2_vlan: 0
FCoE l3_did: 1 l3_sid: 1 l3_oxid: 1
Cabling Considerations for Fabric Port Channels
When you configure the links between the Cisco UCS 2200 Series FEX and a Cisco UCS 6200 series fabric interconnect in fabric port channel mode, the available virtual interface namespace (VIF) on the adapter varies depending on where the FEX uplinks are connected to the fabric interconnect ports.
Inside the 6248 fabric interconnect there are six sets of eight contiguous ports, with each set of ports managed by a single chip. When all uplinks from an FEX are connected to a set of ports managed by a single chip,
Cisco UCS Manager maximizes the number of VIFs used in service profiles deployed on the blades in the chassis. If uplink connections from an IOM are distributed across ports managed by separate chips, the VIF count is decreased.
56
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
SAN Ports and Port Channels
Figure 2: Port Groups for Fabric Port Channels
Viewing Fabric Port Channels
Caution Adding a second link to a fabric-port-channel port group is disruptive and will automatically increase the available amount of VIF namespace from 63 to 118. Adding further links is not disruptive and the VIF namespace stays at 118.
Caution Linking a chassis to two fabric-port-channel port groups does not affect the VIF namespace unless it is manually acknowledged. The VIF namespace is then automatically set to the smaller size fabric port-channel port group usage (either 63 or 118 VIFs) of the two groups.
For high availability cluster-mode applications, we strongly recommend symmetric cabling configurations.
If the cabling is asymmetric, the maximum number of VIFs available is the smaller of the two cabling configurations.
For more information on the maximum number of VIFs for your Cisco UCS environment, see the Configuration
Limits document for your hardware and software configuration.
Viewing Fabric Port Channels
SUMMARY STEPS
1.
UCS-A# scope eth-server
2.
UCS-A /eth-server # scope fabric { a | b }
3.
UCS-A /eth-server/fabric # show fabric-port-channel [ detail | expand ]
DETAILED STEPS
Step 1
Step 2
Command or Action
UCS-A# scope eth-server
Step 3
UCS-A /eth-server # scope fabric { a | b }
UCS-A /eth-server/fabric # show fabric-port-channel
[ detail | expand ]
Purpose
Enters Ethernet server mode.
Enters Ethernet server fabric mode for the specified fabric.
Displays fabric port channels on the specified fabric interconnect.
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
57
SAN Ports and Port Channels
Enabling or Disabling a Fabric Port Channel Member Port
Example
The following example displays information about configured fabric port channels on fabric interconnect A:
UCS-A# scope eth-server
UCS-A /eth-server # scope fabric a
UCS-A /eth-server/fabric # show fabric-port-channel
Fabric Port Channel:
Port Channel Id Chassis Id Admin State Oper State State Reason
--------------- ---------- ----------- ---------------- ------------
1025 1 Enabled Failed No operational members
1026 2 Enabled Up
UCS-A /eth-server/fabric #
Enabling or Disabling a Fabric Port Channel Member Port
SUMMARY STEPS
1.
UCS-A# scope eth-server
2.
UCS-A /eth-server # scope fabric { a | b }
3.
UCS-A /eth-server/fabric # scope fabric-port-channel port-chan-id
4.
UCS-A /eth-server/fabric/fabric-port-channel # scope member-port slot-id port-id
5.
UCS-A /eth-server/fabric/fabric-port-channel # { enable | disable }
6.
UCS-A /eth-server/fabric/fabric-port-channel # commit-buffer
DETAILED STEPS
Step 1
Step 2
Command or Action
UCS-A# scope eth-server
Step 3
UCS-A /eth-server # scope fabric { a | b }
UCS-A /eth-server/fabric # scope fabric-port-channel port-chan-id
Step 4
Step 5
Step 6
Purpose
Enters Ethernet server mode.
Enters Ethernet server fabric mode for the specified fabric.
Enters Ethernet server fabric, fabric port channel mode for the specified fabric.
UCS-A /eth-server/fabric/fabric-port-channel # scope
member-port slot-id port-id
Enters Ethernet server fabric, fabric port channel mode for the specified member port.
UCS-A /eth-server/fabric/fabric-port-channel # { enable | disable }
UCS-A /eth-server/fabric/fabric-port-channel # commit-buffer
Enables or disables the specified member port.
Commits the transaction to the system configuration.
Example
The following example disables fabric channel member port 1 31 on fabric port channel 1025 and commits the transaction:
58
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
SAN Ports and Port Channels
Enabling or Disabling a Fabric Port Channel Member Port
UCS-A# scope eth-server
UCS-A /eth-server # scope fabric a
UCS-A /eth-server/fabric # scope fabric-port-channel 1025
UCS-A /eth-server/fabric/fabric-port-channel # scope member-port 1 31
UCS-A /eth-server/fabric/fabric-port-channel/member-port # disable
UCS-A /eth-server/fabric/fabric-port-channel/member-port* # commit-buffer
UCS-A /eth-server/fabric/fabric-port-channel/member-port #
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
59
Enabling or Disabling a Fabric Port Channel Member Port
SAN Ports and Port Channels
60
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
C H A P T E R
4
Fibre Channel Zoning
•
Information About Fibre Channel Zoning, on page 61
•
Support for Fibre Channel Zoning in Cisco UCS Manager, on page 62
•
Guidelines and recommendations for Cisco UCS Manager-Based Fibre Channel Zoning, on page 64
•
Configuring Cisco UCS Manager Fibre Channel Zoning, on page 64
•
Creating a VSAN for Fibre Channel Zoning, on page 65
•
Creating a New Fibre Channel Zone Profile, on page 67
•
Deleting a Fibre Channel Zone Profile, on page 68
•
Deleting a Fibre Channel User Zone, on page 68
•
Removing Unmanaged Zones from a VSAN Accessible to Both Fabric Interconnects, on page 69
•
Removing Unmanaged Zones from a VSAN Accessible to One Fabric Interconnect, on page 70
•
Configuring Fibre Channel Storage Connection Policies, on page 71
Information About Fibre Channel Zoning
Fibre Channel zoning allows you to partition the Fibre Channel fabric into one or more zones. Each zone defines the set of Fibre Channel initiators and Fibre Channel targets that can communicate with each other in a VSAN. Zoning also enables you to set up access control between hosts and storage devices or user groups.
Note Fibre Channel Zoning is not supported on Cisco UCS 6454 Fabric Interconnect
The access and data traffic control provided by zoning does the following:
• Enhances SAN network security
• Helps prevent data loss or corruption
• Reduces performance issues
Information About Zones
A zone consists of multiple zone members and has the following characteristics:
• Members in a zone can access each other; members in different zones cannot access each other.
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
61
Fibre Channel Zoning
Information About Zone Sets
• Zones can vary in size.
• Devices can belong to more than one zone.
• A physical fabric can have a maximum of 8,000 zones.
Information About Zone Sets
Each zone set consists of one or more zones. You can use zone sets to enforce access control within the Fibre
Channel fabric. In addition, zone sets provide you with the following advantages:
• Only one zone set can be active at any time.
• All zones in a zone set can be activated or deactivated as a single entity across all switches in the fabric.
• Changes to a zone set are not applied until the zone set has been activated. If you make changes to the active zone set, you must reactivate that zone set to apply the changes.
• A zone can be a member of more than one zone set.
• A switch in a zone can have a maximum of 500 zone sets.
Support for Fibre Channel Zoning in Cisco UCS Manager
Cisco UCS Manager supports switch-based Fibre Channel zoning and Cisco UCS Manager-based Fibre
Channel zoning. You cannot configure a combination of zoning types in the same Cisco UCS domain. You can configure a Cisco UCS domain with one of the following types of zoning:
• Cisco UCS Manager-based Fibre Channel zoning—This configuration combines direct attach storage with local zoning. Fibre Channel or FCoE storage is directly connected to the fabric interconnects and zoning is performed in Cisco UCS Manager, using Cisco UCS local zoning. Any existing Fibre Channel or FCoE uplink connections need to be disabled. Cisco UCS does not currently support active Fibre
Channel or FCoE uplink connections coexisting with the utilization of the UCS Local Zoning feature.
• Switch-based Fibre Channel zoning—This configuration combines direct attach storage with uplink zoning. The Fibre Channel or FCoE storage is directly connected to the fabric interconnects and zoning is performed externally to the Cisco UCS domain through an MDS or Nexus 5000 switch. This configuration does not support local zoning in the Cisco UCS domain.
Note Zoning is configured on a per-VSAN basis. You cannot enable zoning at the fabric level.
Cisco UCS Manager-Based Fibre Channel Zoning
With Cisco UCS Manager-based zoning, Cisco UCS Manager controls the Fibre Channel zoning configuration for the Cisco UCS domain, including creating and activating zones for all VSANs that you set up with this type of zoning. This type of zoning is also know as local zoning or direct attach storage with local zoning.
62
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
Fibre Channel Zoning vHBA Initiator Groups
Note You cannot implement Cisco UCS Manager-based zoning if the VSAN is also configured to communicate with a VSAN on an upstream switch and includes Fibre Channel or FCoE uplink ports.
Supported Fibre Channel Zoning Modes
Cisco UCS Manager-based zoning supports the following types of zoning:
• Single initiator single target—Cisco UCS Manager automatically creates one zone for each vHBA and storage port pair. Each zone has two members. We recommend that you configure this type of zoning unless you expect the number of zones to exceed the maximum supported.
• Single initiator multiple targets—Cisco UCS Manager automatically creates one zone for each vHBA.
We recommend that you configure this type of zoning if you expect the number of zones to reach or exceed the maximum supported.
vHBA Initiator Groups
vHBA initiator groups determine the Fibre Channel zoning configuration for all vHBAs in a service profile.
Cisco UCS Manager does not include any default vHBA initiator groups. You must create vHBA initiator groups in any service profile that is to be assigned to servers included in a zone.
The configuration in a vHBA initiator group determines the following:
• The vHBAs included in the initiator group, which are sometimes referred to as vHBA initiators.
• A Fibre Channel storage connection policy, which includes the associated VSAN and the Fibre Channel target ports on the storage array.
• The type of Fibre Channel zoning to be configured for the vHBAs included in the group.
Fibre Channel Storage Connection Policy
The Fibre Channel storage connection policy contains a collection of target storage ports on storage arrays that you use to configure Cisco UCS Manager-based Fibre Channel zoning. You can create this policy under an organization or an initiator group.
The storage arrays in these zones must be directly connected to the fabric interconnects. The target storage ports on these arrays that you include in the Fibre Channel storage connection policy can be either Fibre
Channel storage ports or FCoE storage ports. You use the WWN of a port to add it to the policy and to identify the port for the Fibre Channel zone.
Note Cisco UCS Manager does not create default Fibre Channel storage.
Fibre Channel Active Zone Set Configuration
In each VSAN that has been enabled for Fibre Channel zoning, Cisco UCS Manager automatically configures one zone set and multiple zones. The zone membership specifies the set of initiators and targets that are allowed to communicate with each other. Cisco UCS Manager automatically activates that zone set.
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
63
Fibre Channel Zoning
Switch-Based Fibre Channel Zoning
Cisco UCS Manager processes the user-configured vHBA initiator groups and their associated Fibre Channel storage connection policy to determine the desired connectivity between Fibre Channel initiators and targets.
Cisco UCS Manager uses the following information to build pair-wise zone membership between initiators and targets:
• The port WWNs of the vHBA initiators derived from the vHBA initiator groups.
• The port WWNs of the storage array derived from the storage connection policy.
Switch-Based Fibre Channel Zoning
With switch-based zoning, a Cisco UCS domain inherits the zoning configuration from the upstream switch.
You cannot configure or view information about your zoning configuration in Cisco UCS Manager. You have to disable zoning on a VSAN in Cisco UCS Manager to use switch-based zoning for that VSAN.
GuidelinesandrecommendationsforCiscoUCSManager-Based
Fibre Channel Zoning
When you plan your configuration for Fibre Channel zoning, consider the following guidelines and recommendations:
Fibre Channel Switching Mode Must Be Switch Mode for Cisco UCS Manager Configurations
If you want Cisco UCS Manager to handle Fibre Channel zoning, the fabric interconnects must be in Fibre
Channel Switch mode. You cannot configure Fibre Channel zoning in End-Host mode.
Symmetrical Configuration Is Recommended for High Availability
If a Cisco UCS domain is configured for high availability with two fabric interconnects, we recommend that both fabric interconnects are configured with the same set of VSANs.
Configuring Cisco UCS Manager Fibre Channel Zoning
Note This procedure provides a high level overview of the steps required to configure a Cisco UCS domain for
Fibre Channel zoning that is controlled by Cisco UCS Manager. You must ensure that you complete all of the following steps.
SUMMARY STEPS
1.
If you have not already done so, disconnect the fabric interconnects in the Cisco UCS domain from any external Fibre Channel switches, such as an MDS.
2.
If the Cisco UCS domain still includes zones that were managed by the external Fibre Channel switch, run the clear-unmanaged-fc-zone-all command on every affected VSAN to remove those zones.
3.
Configure the Fibre Channel switching mode for both fabric interconnects in Fibre Channel Switch mode.
64
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
Fibre Channel Zoning
Creating a VSAN for Fibre Channel Zoning
4.
Configure the Fibre Channel and FCoE storage ports that you require to carry traffic for the Fibre Channel zones.
5.
Create one or more VSANs and enable Fibre Channel zoning on all VSANs that you require to carry traffic for the Fibre Channel zones.
6.
Create one or more Fibre Channel storage connection policies.
7.
Configure zoning in service profiles or service profile templates for servers that need to communicate through Fibre Channel zones.
DETAILED STEPS
Step 1
Step 2
Step 3
Step 4
Step 5
Step 6
Step 7
Command or Action Purpose
If you have not already done so, disconnect the fabric interconnects in the Cisco UCS domain from any external
Fibre Channel switches, such as an MDS.
If the Cisco UCS domain still includes zones that were managed by the external Fibre Channel switch, run the clear-unmanaged-fc-zone-all command on every affected
VSAN to remove those zones.
This functionality is not currently available in the Cisco
UCS Manager GUI. You must perform this step in the Cisco
UCS Manager CLI.
Configure the Fibre Channel switching mode for both fabric interconnects in Fibre Channel Switch mode.
You cannot configure Fibre Channel zoning in End-Host mode.
Configure the Fibre Channel and FCoE storage ports that you require to carry traffic for the Fibre Channel zones.
Create one or more VSANs and enable Fibre Channel zoning on all VSANs that you require to carry traffic for the Fibre Channel zones.
For a cluster configuration, we recommend that you create the VSANs that you intend to include in a Fibre Channel zone in Fibre Channel storage mode and accessible to both fabric interconnects.
Create one or more Fibre Channel storage connection policies.
You can perform this step when you configure Fibre
Channel zoning in the service profiles, if you prefer.
Configure zoning in service profiles or service profile templates for servers that need to communicate through
Fibre Channel zones.
Complete the following steps to complete this configuration:
• Enable zoning in the VSAN or VSANs assigned to the
VHBAs.
• Configure one or more vHBA initiator groups.
Creating a VSAN for Fibre Channel Zoning
SUMMARY STEPS
1.
UCS-A# scope fc-uplink
2.
UCS-A /fc-uplink # create vsan { VSAN_Name } { VSAN_ID } { FCoE_VLAN_ID }
3.
UCS-A /fc-uplink # commit-buffer
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
65
Fibre Channel Zoning
Creating a VSAN for Fibre Channel Zoning
DETAILED STEPS
Step 1
Step 2
Command or Action
UCS-A# scope fc-uplink
Purpose
Enters Fibre Channel uplink mode.
UCS-A /fc-uplink # create vsan { VSAN_Name } { VSAN_ID }
{ FCoE_VLAN_ID }
Enter the following:
• VSAN_Name- The name assigned to the network. This name can be between 1 and 32 alphanumeric characters. You cannot use spaces or any special characters other than - (hyphen), _ (underscore), :
(colon), and . (period), and you cannot change this name after the object is saved.
• VSAN_ID- The unique identifier assigned to the network. The ID can be between 1 and 4078, or between 4080 and 4093. 4079 is a reserved VSAN ID.
• FCoE_VLAN_ID- The unique identifier assigned to the VLAN used for Fibre Channel connections. The
ID can be between 1 and 4029, or between 4048 and
4093. VLAN 4048 is user configurable. However,
Cisco UCS Manager uses VLAN 4048 for the following default values. If you want to assign 4048 to a VLAN, you must reconfigure these values:
• After an upgrade to Cisco UCS, Release 2.0—The
FCoE storage port native VLAN uses VLAN
4048 by default. If the default FCoE VSAN was set to use VLAN 1 before the upgrade, you must change it to a VLAN ID that is not used or reserved. For example, consider changing the default to 4049 if that VLAN ID is not in use.
• After a fresh install of Cisco UCS, Release
2.0—The FCoE VLANfor the default VSAN uses
VLAN 4048 by default. The FCoEstorage port native VLAN uses VLAN 4049.
For FIP-capable, converged network adapters, such as the
Cisco UCSCNA M72KR-Q and the Cisco UCS CNA
M72KR-E, the named VSANmust be configured with a named VLAN that is not the native VLANfor the FCoE
VLAN ID. This configuration ensures that FCoE trafficcan pass through these adapters.
Step 3 UCS-A /fc-uplink # commit-buffer
Example
The following examples creates a VSAN named TestVsan and commits the changes in the system:
66
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
Fibre Channel Zoning
Creating a New Fibre Channel Zone Profile
UCS-A # scope fc-uplink
UCS-A /fc-uplink # create vsan TestVsan 2 30
UCS-A /fc-uplink/vsan* # commit-buffer
UCS-A /fc-uplink/vsan #
Creating a New Fibre Channel Zone Profile
Perform the following procedure to create a new Fibre Channel Zone Profile.
Before you begin
Ensure that the VSAN is created for the Fiber Channel Zoning.
SUMMARY STEPS
1.
UCS-A # scope fc-storage
2.
UCS-A /fc-storage # create fc-zone-profile Profile_Name
3.
UCS-A /fc-storage/fc-zone-profile * # create fc-user-zone Zone_Name
4.
UCS-A /fc-storage/fc-zone-profile/fc-user-zone* # set path { A | B }
5.
UCS-A /fc-storage/fc-zone-profile/fc-user-zone* # set vsan VSAN_Name
6.
UCS-A /fc-storage/fc-zone-profile/fc-user-zone* # create member wwpn
7.
UCS-A /fc-storage/fc-zone-profile/fc-user-zone* # commit-buffer
DETAILED STEPS
Step 1
Step 2
Step 3
Step 4
Step 5
Step 6
Step 7
Command or Action
UCS-A # scope fc-storage
Purpose
Enters Fibre Channel storage mode.
UCS-A /fc-storage # create fc-zone-profile Profile_Name Creates a Fibre Channel profile with the specified name.
UCS-A /fc-storage/fc-zone-profile * # create fc-user-zone
Zone_Name
Enters Fibre Channel zone profile mode and creates the specified Fibre Channel zone.
UCS-A /fc-storage/fc-zone-profile/fc-user-zone* # set path
{ A | B }
Sets the Fibre Channel zone path.
UCS-A /fc-storage/fc-zone-profile/fc-user-zone* # set vsan
VSAN_Name
Sets the Fibre Channel zone to the named VSAN.
UCS-A /fc-storage/fc-zone-profile/fc-user-zone* # create
member wwpn
Creates the WWPN for the Fibre Channel zone profile.
UCS-A /fc-storage/fc-zone-profile/fc-user-zone* # commit-buffer
Commits the transaction to the system configuration.
Example
The following example shows how to create FC Zoning Policy named myProfilie:
UCS-A# scope fc-storage
UCS-A /fc-storage # create fc-zone-profile myProfile
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
67
Fibre Channel Zoning
Deleting a Fibre Channel Zone Profile
UCS-A /fc-storage/fc-zone-profile* # create fc-user-zone myZone
UCS-A /fc-storage/fc-zone-profile/fc-user-zone* # set path A
UCS-A /fc-storage/fc-zone-profile/fc-user-zone* # set vsan test
UCS-A /fc-storage/fc-zone-profile/fc-user-zone* # create member 20:c2:11:25:b5:00:00:7f
UCS-A /fc-storage/fc-zone-profile/fc-user-zone/member* # commit-buffer
Deleting a Fibre Channel Zone Profile
Perform the following procedure to delete a Fibre Channel Zone Profile.
SUMMARY STEPS
1.
UCS-A # scope fc-storage
2.
UCS-A /fc-storage # delete fc-zone-profile Profile_Name
3.
UCS-A /fc-storage* # commit-buffer
DETAILED STEPS
Step 1
Step 2
Step 3
Command or Action
UCS-A # scope fc-storage
Purpose
Enters Fibre Channel storage mode.
UCS-A /fc-storage # delete fc-zone-profile Profile_Name Deletes a Fibre Channel profile with the specified name.
UCS-A /fc-storage* # commit-buffer Commits the transaction to the system configuration.
Example
The following example shows how to delete an FC Zone Profile named myProfile:
UCS-A # scope fc-storage
UCS-A /fc-storage # delete fc-zone-profile myProfile
UCS-A /fc-storage* # commit-buffer
UCS-A /fc-storage #
Deleting a Fibre Channel User Zone
Perform the following procedure to delete a Fibre Channel User Zone.
SUMMARY STEPS
1.
UCS-A # scope fc-storage
2.
UCS-A /fc-storage # scope fc-zone-profile Profile_Name
3.
UCS-A /fc-storage/fc-zone-profile # delete fc-user-zone Userzone_Name
4.
UCS-A /fc-storage/fc-zone-profile* # commit-buffer
68
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
Fibre Channel Zoning
Removing Unmanaged Zones from a VSAN Accessible to Both Fabric Interconnects
DETAILED STEPS
Step 1
Step 2
Command or Action
UCS-A # scope fc-storage
Step 3
Step 4
Purpose
Enters Fibre Channel storage mode.
UCS-A /fc-storage # scope fc-zone-profile Profile_Name Enters the specified Fibre Channel profile.
UCS-A /fc-storage/fc-zone-profile #
Userzone_Name delete fc-user-zone
UCS-A /fc-storage/fc-zone-profile* # commit-buffer
Deletes the specified Fibre Channel User Zone.
Commits the transaction to the system configuration.
Example
The following example shows how to delete an FC User Zone Profile named myZone:
UCS-A # scope fc-storage
UCS-A /fc-storage # scope fc-zone-profile myProfile
UCS-A /fc-storage/fc-zone-profile # delete fc-user-zone myZone
UCS-A /fc-storage/fc-zone-profile* # commit-buffer
UCS-A /fc-storage #
Removing Unmanaged Zones from a VSAN Accessible to Both
Fabric Interconnects
After you disconnect the external Fibre Channel switch, the Fibre Channel zones that were managed by that switch might not been cleared from the Cisco UCS domain. This procedure removes those zones from each
VSAN in the Cisco UCS domain so that you can configure Fibre Channel zoning in Cisco UCS.
Before you begin
If you have not already done so, disconnect the fabric interconnects in the Cisco UCS domain from any external Fibre Channel switches, such as an MDS.
SUMMARY STEPS
1.
UCS-A# scope fc-uplink
2.
UCS-A /fc-uplink # scope fabric { a | b }
3.
UCS-A /fc-uplink/fabric # scope vsan vsan-name
4.
UCS-A /fc-uplink/fabric/vsan # clear-unmanaged-fc-zones-all
5.
UCS-A /fc-uplink/fabric/vsan # commit-buffer
DETAILED STEPS
Step 1
Step 2
Command or Action
UCS-A# scope fc-uplink
UCS-A /fc-uplink # scope fabric { a | b }
Purpose
Enters Fibre Channel uplink mode.
Enters Fibre Channel uplink mode for the specified fabric interconnect.
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
69
Fibre Channel Zoning
Removing Unmanaged Zones from a VSAN Accessible to One Fabric Interconnect
Step 3
Step 4
Command or Action
UCS-A /fc-uplink/fabric # scope vsan vsan-name
UCS-A /fc-uplink/fabric/vsan # clear-unmanaged-fc-zones-all
Step 5 UCS-A /fc-uplink/fabric/vsan # commit-buffer
Purpose
Enters VSAN mode for the specified named VSAN.
Clears all unmanaged Fibre Channel zones from the specified named VSAN.
If desired, you can repeat Steps 2 through 4 to remove unmanaged zones from all VSANs that are accessible to the specified fabric interconnect before you commit the buffer.
Commits the transaction to the system configuration.
Example
The following example shows how to remove unmanaged zones from a named VSAN accessible to fabric interconnect A and commit the transaction:
UCS-A# scope fc-uplink
UCS-A /fc-uplink # scope fabric a
UCS-A /fc-uplink/fabric # scope vsan finance
UCS-A /fc-uplink/fabric/vsan # clear-unmanaged-fc-zones-all
UCS-A /fc-uplink/fabric/vsan* # commit-buffer
UCS-A /fc-uplink #
Removing Unmanaged Zones from a VSAN Accessible to One
Fabric Interconnect
After you disconnect the external Fibre Channel switch, the Fibre Channel zones that were managed by that switch might not been cleared from the Cisco UCS domain. This procedure removes those zones from each
VSAN in the Cisco UCS domain so that you can configure Fibre Channel zoning in Cisco UCS.
Before you begin
If you have not already done so, disconnect the fabric interconnects in the Cisco UCS domain from any external Fibre Channel switches, such as an MDS.
SUMMARY STEPS
1.
UCS-A# scope fc-uplink
2.
UCS-A /fc-uplink # scope vsan vsan-name
3.
UCS-A /fc-uplink/vsan # clear-unmanaged-fc-zones-all
4.
UCS-A /fc-uplink/vsan # commit-buffer
DETAILED STEPS
Step 1
Command or Action
UCS-A# scope fc-uplink
Purpose
Enters Fibre Channel uplink mode.
70
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
Fibre Channel Zoning
Configuring Fibre Channel Storage Connection Policies
Step 2
Step 3
Step 4
Command or Action
UCS-A /fc-uplink # scope vsan vsan-name
Purpose
Enters VSAN mode for the specified named VSAN.
UCS-A /fc-uplink/vsan # clear-unmanaged-fc-zones-all Clears all unmanaged Fibre Channel zones from the specified named VSAN.
If desired, you can repeat steps 2 and 3 to remove unmanaged zones from all VSANs that are accessible to both fabric interconnects before you commit the buffer.
UCS-A /fc-uplink/vsan # commit-buffer Commits the transaction to the system configuration.
Example
The following example shows how to remove unmanaged zones from a named VSAN and commit the transaction:
UCS-A# scope fc-uplink
UCS-A /fc-uplink # scope vsan finance
UCS-A /fc-uplink/vsan # clear-unmanaged-fc-zones-all
UCS-A /fc-uplink/vsan* # commit-buffer
UCS-A /fc-uplink #
Configuring Fibre Channel Storage Connection Policies
Creating a Fibre Channel Storage Connection Policy
SUMMARY STEPS
DETAILED STEPS
Step 1
Command or Action
UCS-A# scope org org-name
Step 2
1.
UCS-A# scope org org-name
2.
UCS-A /org # create storage-connection-policy policy-name
3.
UCS-A /org # set zoning-type { none | simt | sist }
4.
UCS-A /org/storage-connection-policy # create storage-target wwpn
5.
UCS-A /org/storage-connection-policy/storage-target # set target-path { a | b }
6.
UCS-A /org/storage-connection-policy/storage-target # set target-vsan vsan
7.
UCS-A /org/storage-connection-policy # commit-buffer
UCS-A /org # policy-name create storage-connection-policy
Purpose
Enters the organization mode for the specified organization.
To enter the root organization mode, enter / as the org-name .
Creates a storage connection policy with the specified policy name, and enters organization storage connection policy mode.
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
71
Fibre Channel Zoning
Deleting a Fibre Channel Storage Connection Policy
Step 3
Step 4
Step 5
Step 6
Step 7
Command or Action
UCS-A /org # set zoning-type { none | simt | sist }
Purpose
• None —Cisco UCS Manager does not configure Fibre
Channel zoning.
• Single Initiator Single Target —Cisco UCS Manager automatically creates one zone for each vHBA and storage port pair. Each zone has two members. We recommend that you configure this type of zoning unless you expect the number of zones to exceed the maximum supported.
• Single Initiator Multiple Targets —Cisco UCS
Manager automatically creates one zone for each vHBA. We recommend that you configure this type of zoning if you expect the number of zones to reach or exceed the maximum supported.
UCS-A /org/storage-connection-policy # create storage-target wwpn
Creates a storage target endpoint with the specified WWPN, and enters storage target mode.
UCS-A /org/storage-connection-policy/storage-target # set target-path { a | b }
Specifies which fabric interconnect is used for communications with the target endpoint.
UCS-A /org/storage-connection-policy/storage-target # set target-vsan vsan
Specifies which VSAN is used for communications with the target endpoint.
UCS-A /org/storage-connection-policy # commit-buffer Commits the transaction to the system configuration.
Example
The following example configures a Fibre Channel storage connection policy in the root organization named scPolicyZone1, using fabric interconnect A and the default VSAN, and commits the transaction:
UCS-A# scope org /
UCS-A /org* # create storage-connection-policy scPolicyZone1
UCS-A /org/storage-connection-policy* set zoning-type sist
UCS-A /org/storage-connection-policy* # create storage-target 20:10:20:30:40:50:60:70
UCS-A /org/storage-connection-policy/storage-target* # set target-path a
UCS-A /org/storage-connection-policy/storage-target* # set target-vsan default
UCS-A /org/storage-connection-policy* # commit-buffer
UCS-A /org/storage-connection-policy #
Deleting a Fibre Channel Storage Connection Policy
SUMMARY STEPS
1.
UCS-A# scope org org-name
2.
UCS-A /org # delete storage-connection-policy policy-name
3.
UCS-A /org # commit-buffer
72
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
Fibre Channel Zoning
Deleting a Fibre Channel Storage Connection Policy
DETAILED STEPS
Step 1
Step 2
Step 3
Command or Action
UCS-A# scope org org-name
UCS-A /org # delete storage-connection-policy policy-name
UCS-A /org # commit-buffer
Purpose
Enters the organization mode for the specified organization.
To enter the root organization mode, enter / as the org-name .
Deletes the specified storage connection policy.
Commits the transaction to the system configuration.
Example
The following example deletes the storage connection policy named scPolicyZone1 from the root organization and commits the transaction:
UCS-A# scope org /
UCS-A /org # delete san-connectivity-policy scPolicyZone1
UCS-A /org* # commit-buffer
UCS-A /org #
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
73
Deleting a Fibre Channel Storage Connection Policy
Fibre Channel Zoning
74
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
C H A P T E R
5
Named VSANs
•
•
Fibre Channel Uplink Trunking for Named VSANs, on page 76
•
Guidelines and Recommendations for VSANs, on page 76
•
•
•
Creating a Named VSAN Accessible to One Fabric Interconnect (Fibre Channel Uplink Mode), on page
•
Creating a Named VSAN Accessible to One Fabric Interconnect (Fibre Channel Storage Mode), on page
•
Deleting a Named VSAN, on page 83
•
Changing the VLAN ID for the FCoE Native VLAN for a Named VSAN, on page 84
•
Changing the VLAN ID for the FCoE Native VLAN for a Storage VSAN, on page 85
•
Enabling or Disabling Fibre Channel Uplink Trunking, on page 85
Named VSANs
A named VSAN creates a connection to a specific external SAN. The VSAN isolates traffic to that external
SAN, including broadcast traffic. The traffic on one named VSAN knows that the traffic on another named
VSAN exists, but cannot read or access that traffic.
Like a named VLAN, the name that you assign to a VSAN ID adds a layer of abstraction that allows you to globally update all servers associated with service profiles that use the named VSAN. You do not need to reconfigure the servers individually to maintain communication with the external SAN. You can create more than one named VSAN with the same VSAN ID.
Named VSANs in Cluster Configurations
In a cluster configuration, a named VSAN can be configured to be accessible only to the Fibre Channel uplink ports on one fabric interconnect or to the Fibre Channel uplink ports on both fabric interconnects.
Named VSANs and the FCoE VLAN ID
You must configure each named VSAN with an FCoE VLAN ID. This property determines which VLAN is used for transporting the VSAN and its Fibre Channel packets.
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
75
Named VSANs
Fibre Channel Uplink Trunking for Named VSANs
For FIP-capable, converged network adapters, such as the Cisco UCS CNA M72KR-Q and the Cisco UCS
CNA M72KR-E, the named VSAN must be configured with a named VLAN that is not the native VLAN for the FCoE VLAN ID. This configuration ensures that FCoE traffic can pass through these adapters.
In the following sample configuration, a service profile with a vNIC and vHBA mapped to fabric A is associated with a server that has FIP capable, converged network adapters:
• The vNIC is configured to use VLAN 10.
• VLAN 10 is also designated as the native VLAN for the vNIC.
• The vHBA is configured to use VSAN 2.
• Therefore, VSAN 2 cannot be configured with VLAN 10 as the FCoE VLAN ID. VSAN 2 can be mapped to any other VLAN configured on fabric A.
Fibre Channel Uplink Trunking for Named VSANs
You can configure Fibre Channel uplink trunking for the named VSANs on each fabric interconnect. If you enable trunking on a fabric interconnect, all named VSANs in a Cisco UCS domain are allowed on all Fibre
Channel uplink ports on that fabric interconnect.
Guidelines and Recommendations for VSANs
The following guidelines and recommendations apply to all named VSANs, including storage VSANs.
VSAN 4079 is a Reserved VSAN ID
Do not configure a VSAN as 4079. This VSAN is reserved and cannot be used in either FC switch mode or
FC end-host mode.
If you create a named VSAN with ID 4079, Cisco UCS Manager marks that VSAN with an error and raises a fault.
Reserved VSAN Range for Named VSANs in FC Switch Mode
If you plan to use FC switch mode in a Cisco UCS domain, do not configure VSANs with an ID in the range from 3040 to 4078.
VSANs in that range are not operational if the fabric interconnects are configured to operate in FC switch mode. Cisco UCS Manager marks that VSAN with an error and raises a fault.
Reserved VSAN Range for Named VSANs in FC End-Host Mode
If you plan to use FC end-host mode in a Cisco UCS domain, do not configure VSANs with an ID in the range from 3840 to 4079.
VSANs in that range are not operational if the following conditions exist in a Cisco UCS domain:
• The fabric interconnects are configured to operate in FC end-host mode.
• The Cisco UCS domain is configured with Fibre Channel trunking or SAN port channels.
76
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
Named VSANs
Guidelines and Recommendations for VSANs
If these configurations exist, Cisco UCS Manager does the following:
1.
Renders all VSANs with an ID in the range from 3840 to 4079 non-operational.
2.
Raises a fault against the non-operational VSANs.
3.
Transfers all non-operational VSANs to the default VSAN.
4.
Transfers all vHBAs associated with the non-operational VSANs to the default VSAN.
If you disable Fibre Channel trunking and delete any existing SAN port channels, Cisco UCS Manager returns all VSANs in the range from 3840 to 4078 to an operational state and restores any associated vHBAs back to those VSANs.
Range Restrictions for Named VSAN IDs in FC Switch Mode
If you plan to use FC switch mode in a Cisco UCS domain, do not configure VSANs in the range from 3040 to 4078.
When a fabric interconnect operating in FC switch mode is connected to MDS as the upstream switch, VSANs configured in Cisco UCS Manager in the range from 3040 to 4078 and assigned as port VSANs cannot be created in MDS. This configuration results in a possible port VSAN mismatch.
Guidelines for FCoE VLAN IDs
Note FCoE VLANs in the SAN cloud and VLANs in the LAN cloud must have different IDs. Using the same ID for an FCoE VLAN in a VSAN and a VLAN results in a critical fault and traffic disruption for all vNICs and uplink ports using that FCoE VLAN. Ethernet traffic is dropped on any VLAN with an ID that overlaps with an FCoE VLAN ID.
VLAN 4048 is user configurable. However, Cisco UCS Manager uses VLAN 4048 for the following default values. If you want to assign 4048 to a VLAN, you must reconfigure these values:
• After an upgrade to Cisco UCS, Release 2.0—The FCoE storage port native VLAN uses VLAN 4048 by default. If the default FCoE VSAN was set to use VLAN 1 before the upgrade, you must change it to a VLAN ID that is not used or reserved. For example, consider changing the default to 4049 if that
VLAN ID is not in use.
• After a fresh install of Cisco UCS, Release 2.0—The FCoE VLAN for the default VSAN uses VLAN
4048 by default. The FCoE storage port native VLAN uses VLAN 4049.
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
77
Named VSANs
Creating a Named VSAN Accessible to Both Fabric Interconnects (Fibre Channel Uplink Mode)
Creating a Named VSAN Accessible to Both Fabric
Interconnects (Fibre Channel Uplink Mode)
Note FCoE VLANs in the SAN cloud and VLANs in the LAN cloud must have different IDs. Using the same ID for an FCoE VLAN in a VSAN and a VLAN results in a critical fault and traffic disruption for all vNICs and uplink ports using that FCoE VLAN. Ethernet traffic is dropped on any VLAN with an ID that overlaps with an FCoE VLAN ID.
SUMMARY STEPS
1.
UCS-A# scope fc-uplink
2.
UCS-A /fc-uplink # create vsan vsan-name vsan-id fcoe-id
3.
UCS-A /fc-uplink/vsan # set fc-zoning { disabled | enabled }
4.
UCS-A /fc-uplink/vsan # commit-buffer
DETAILED STEPS
Step 1
Step 2
Command or Action
UCS-A# scope fc-uplink
UCS-A /fc-uplink # create vsan vsan-name vsan-id fcoe-id
Purpose
Enters Fibre Channel uplink mode.
Creates the specified named VSAN, specifies the VSAN name, VSAN ID and FCoE VLAN ID, and enters Fibre
Channel uplink VSAN mode.
• After an upgrade to Cisco UCS, Release 2.0—The
FCoE storage port native VLAN uses VLAN 4048 by default. If the default FCoE VSAN was set to use
VLAN 1 before the upgrade, you must change it to a
VLAN ID that is not used or reserved. For example, consider changing the default to 4049 if that VLAN
ID is not in use.
• After a fresh install of Cisco UCS, Release 2.0—The
FCoE VLAN for the default VSAN uses VLAN 4048 by default. The FCoE storage port native VLAN uses
VLAN 4049.
Step 3 UCS-A /fc-uplink/vsan # set fc-zoning { disabled | enabled }
Configures Fibre Channel zoning for the VSAN, as follows:
• disabled—The upstream switch configures and controls the Fibre Channel zoning or Fibre Channel zoning is not implemented on this VSAN.
• enabled—Cisco UCS Manager configures and controls
Fibre Channel zoning.
78
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
Named VSANs
Creating a Named VSAN Accessible to Both Fabric Interconnects (Fibre Channel Storage Mode)
Step 4
Command or Action
UCS-A /fc-uplink/vsan # commit-buffer
Purpose
Commits the transaction to the system configuration.
Example
The following example creates a named VSAN for both fabric interconnects, names the VSAN accounting, assigns the VSAN ID 2112, assigns the FCoE VLAN ID 4021, enables the VSAN for
Cisco UCS Manager-based Fibre Channel zoning, and commits the transaction:
UCS-A# scope fc-uplink
UCS-A /fc-uplink* # create vsan accounting 2112 4021
UCS-A /fc-uplink/vsan # set fc-zoning enabled
UCS-A /fc-uplink/vsan* # commit-buffer
UCS-A /fc-uplink/vsan #
Creating a Named VSAN Accessible to Both Fabric
Interconnects (Fibre Channel Storage Mode)
Note FCoE VLANs in the SAN cloud and VLANs in the LAN cloud must have different IDs. Using the same ID for an FCoE VLAN in a VSAN and a VLAN results in a critical fault and traffic disruption for all vNICs and uplink ports using that FCoE VLAN. Ethernet traffic is dropped on any VLAN with an ID that overlaps with an FCoE VLAN ID.
SUMMARY STEPS
1.
UCS-A# scope fc-storage
2.
UCS-A /fc-storage # create vsan vsan-name vsan-id fcoe-id
3.
UCS-A /fc-storage/vsan # create member-port { fc | fcoe } { a | b } slot-id port-id
4.
UCS-A /fc-storage/vsan # set fc-zoning { disabled | enabled }
5.
UCS-A /fc-storage/vsan # commit-buffer
DETAILED STEPS
Step 1
Step 2
Command or Action
UCS-A# scope fc-storage
Purpose
Enters Fibre Channel storage mode.
UCS-A /fc-storage # create vsan vsan-name vsan-id fcoe-id Creates the specified named VSAN, specifies the VSAN name, VSAN ID, and FCoE VLAN ID, and enters Fibre
Channel storage VSAN mode.
• After an upgrade to Cisco UCS, Release 2.0—The
FCoE storage port native VLAN uses VLAN 4048 by default. If the default FCoE VSAN was set to use
VLAN 1 before the upgrade, you must change it to a
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
79
Named VSANs
Creating a Named VSAN Accessible to One Fabric Interconnect (Fibre Channel Uplink Mode)
Step 3
Step 4
Step 5
Command or Action Purpose
VLAN ID that is not used or reserved. For example, consider changing the default to 4049 if that VLAN
ID is not in use.
• After a fresh install of Cisco UCS, Release 2.0—The
FCoE VLAN for the default VSAN uses VLAN 4048 by default. The FCoE storage port native VLAN uses
VLAN 4049.
UCS-A /fc-storage/vsan # create member-port { fc | fcoe }
{ a | b } slot-id port-id
Creates a member port; specifies whether the port type, fabric, slot ID and port ID.
UCS-A /fc-storage/vsan # set fc-zoning { disabled | enabled }
Configures Fibre Channel zoning for the VSAN, as follows:
• disabled—The upstream switch configures and controls the Fibre Channel zoning or Fibre Channel zoning is not implemented on this VSAN.
• enabled—Cisco UCS Manager configures and controls
Fibre Channel zoning.
UCS-A /fc-storage/vsan # commit-buffer Commits the transaction to the system configuration.
Example
The following example creates a named VSAN, names the VSAN finance, assigns the VSAN ID
3955, assigns the FCoE VLAN ID 4021, creates a member port and assigns it to member port A, slot 1 port 40, enables the VSAN for Cisco UCS Manager-based Fibre Channel zoning, and commits the transaction:
UCS-A# scope fc-storage
UCS-A /fc-storage/ # create VSAN finance 3955 4021
UCS-A /fc-storage/vsan # create member-port fcoe a 1 40
UCS-A /fc-storage/vsan # set fc-zoning enabled
UCS-A /fc-storage/vsan/member-port* # commit-buffer
UCS-A /fc-storage/vsan/member-port #
Creating a Named VSAN Accessible to One Fabric Interconnect
(Fibre Channel Uplink Mode)
Note FCoE VLANs in the SAN cloud and VLANs in the LAN cloud must have different IDs. Using the same ID for an FCoE VLAN in a VSAN and a VLAN results in a critical fault and traffic disruption for all vNICs and uplink ports using that FCoE VLAN. Ethernet traffic is dropped on any VLAN with an ID that overlaps with an FCoE VLAN ID.
80
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
Named VSANs
Creating a Named VSAN Accessible to One Fabric Interconnect (Fibre Channel Uplink Mode)
SUMMARY STEPS
DETAILED STEPS
Step 1
Step 2
Command or Action
UCS-A# scope fc-uplink
UCS-A /fc-uplink # scope fabric { a | b }
Step 3
1.
UCS-A# scope fc-uplink
2.
UCS-A /fc-uplink # scope fabric { a | b }
3.
UCS-A /fc-uplink/fabric # create vsan vsan-name vsan-id fcoe-id
4.
UCS-A /fc-uplink/vsan # set fc-zoning { disabled | enabled }
5.
UCS-A /fc-uplink/fabric/vsan # commit-buffer
UCS-A /fc-uplink/fabric # vsan-id fcoe-id create vsan vsan-name
Purpose
Enters Fibre Channel uplink mode.
Enters Fibre Channel uplink fabric interconnect mode for the specified fabric interconnect (A or B).
Creates the specified named VSAN, specifies the VSAN name, VSAN ID, and FCoE VLAN ID, and enters Fibre
Channel uplink VSAN mode.
• After an upgrade to Cisco UCS, Release 2.0—The
FCoE storage port native VLAN uses VLAN 4048 by default. If the default FCoE VSAN was set to use
VLAN 1 before the upgrade, you must change it to a
VLAN ID that is not used or reserved. For example, consider changing the default to 4049 if that VLAN
ID is not in use.
• After a fresh install of Cisco UCS, Release 2.0—The
FCoE VLAN for the default VSAN uses VLAN 4048 by default. The FCoE storage port native VLAN uses
VLAN 4049.
Step 4 UCS-A /fc-uplink/vsan # set fc-zoning { disabled | enabled }
Configures Fibre Channel zoning for the VSAN, as follows:
• disabled—The upstream switch configures and controls the Fibre Channel zoning or Fibre Channel zoning is not implemented on this VSAN.
• enabled—Cisco UCS Manager configures and controls
Fibre Channel zoning.
Step 5 UCS-A /fc-uplink/fabric/vsan # commit-buffer Commits the transaction to the system configuration.
Example
The following example creates a named VSAN for fabric interconnect A, names the VSAN finance, assigns the VSAN ID 3955, assigns the FCoE VLAN ID 2221, enables the VSAN for Cisco UCS
Manager-based Fibre Channel zoning, and commits the transaction:
UCS-A# scope fc-uplink
UCS-A /fc-uplink # scope fabric a
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
81
Named VSANs
Creating a Named VSAN Accessible to One Fabric Interconnect (Fibre Channel Storage Mode)
UCS-A /fc-uplink/fabric # create vsan finance 3955 2221
UCS-A /fc-uplink/vsan # set fc-zoning enabled
UCS-A /fc-uplink/fabric/vsan* # commit-buffer
UCS-A /fc-uplink/fabric/vsan #
Creating a Named VSAN Accessible to One Fabric Interconnect
(Fibre Channel Storage Mode)
Note FCoE VLANs in the SAN cloud and VLANs in the LAN cloud must have different IDs. Using the same ID for an FCoE VLAN in a VSAN and a VLAN results in a critical fault and traffic disruption for all vNICs and uplink ports using that FCoE VLAN. Ethernet traffic is dropped on any VLAN with an ID that overlaps with an FCoE VLAN ID.
SUMMARY STEPS
1.
UCS-A# scope fc-storage
2.
UCS-A /fc-storage # scope fabric { a | b }
3.
UCS-A /fc-storage/fabric # create vsan vsan-name vsan-id fcoe-id
4.
UCS-A /fc-storage/fabric/vsan # create member-port { fc | fcoe } { a | b } slot-id port-id
5.
UCS-A /fc-storage/vsan # set fc-zoning { disabled | enabled }
6.
UCS-A /fc-storage/fabric/vsan # commit-buffer
DETAILED STEPS
Step 1
Step 2
Command or Action
UCS-A# scope fc-storage
UCS-A /fc-storage # scope fabric { a | b }
Step 3
Purpose
Enters Fibre Channel storage mode.
Enters Fibre Channel storage mode for the specified fabric interconnect.
UCS-A /fc-storage/fabric # create vsan vsan-name vsan-id fcoe-id
Creates the specified named VSAN, specifies the VSAN name, VSAN ID, and FCoE VLAN ID, and enters Fibre
Channel storage VSAN mode.
• After an upgrade to Cisco UCS, Release 2.0—The
FCoE storage port native VLAN uses VLAN 4048 by default. If the default FCoE VSAN was set to use
VLAN 1 before the upgrade, you must change it to a
VLAN ID that is not used or reserved. For example, consider changing the default to 4049 if that VLAN
ID is not in use.
• After a fresh install of Cisco UCS, Release 2.0—The
FCoE VLAN for the default VSAN uses VLAN 4048 by default. The FCoE storage port native VLAN uses
VLAN 4049.
82
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
Named VSANs
Deleting a Named VSAN
Step 4
Step 5
Step 6
Command or Action
UCS-A /fc-storage/vsan # set fc-zoning { disabled | enabled }
Purpose
UCS-A /fc-storage/fabric/vsan # create member-port { fc
| fcoe } { a | b } slot-id port-id
Creates a member port on the specified VSAN.
Configures Fibre Channel zoning for the VSAN, as follows:
• disabled—The upstream switch configures and controls the Fibre Channel zoning or Fibre Channel zoning is not implemented on this VSAN.
• enabled—Cisco UCS Manager configures and controls
Fibre Channel zoning.
UCS-A /fc-storage/fabric/vsan # commit-buffer Commits the transaction to the system configuration.
Example
The following example creates a named VSAN on fabric A, names the VSAN finance, assigns the
VSAN ID 3955, assigns the FCoE VLAN ID 2221, creates a member port and assigns the it to member port A, slot 1 port 40, and commits the transaction:
UCS-A# scope fc-storage
UCS-A /fc-storage/ # scope fabric a
UCS-A /fc-storage/fabric # create VSAN finance 3955 2221
UCS-A /fc-storage/fabric/vsan # create member-port a 1 40
UCS-A /fc-storage/fabric/vsan # set fc-zoning enabled
UCS-A /fc-storage/fabric/vsan/member-port* # commit-buffer
UCS-A /fc-storage/fabric/vsan/member-port #
Deleting a Named VSAN
If Cisco UCS Manager includes a named VSAN with the same VSAN ID as the one you delete, the VSAN is not removed from the fabric interconnect configuration until all named VSANs with that ID are deleted.
SUMMARY STEPS
1.
UCS-A# scope fc-uplink
2.
UCS-A /fc-uplink # delete vsan vsan-name
3.
UCS-A /fc-uplink # commit-buffer
DETAILED STEPS
Step 1
Step 2
Command or Action
UCS-A# scope fc-uplink
Step 3
UCS-A /fc-uplink # delete vsan vsan-name
UCS-A /fc-uplink # commit-buffer
Purpose
Enters Fibre Channel uplink mode.
Deletes the specified named VSAN.
Commits the transaction to the system configuration.
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
83
Named VSANs
Changing the VLAN ID for the FCoE Native VLAN for a Named VSAN
Example
The following example shows how to delete a named VSAN and commit the transaction:
UCS-A# scope fc-uplink
UCS-A /fc-uplink # delete vsan finance
UCS-A /fc-uplink* # commit-buffer
UCS-A /fc-uplink #
Changing the VLAN ID for the FCoE Native VLAN for a Named
VSAN
Note FCoE VLANs in the SAN cloud and VLANs in the LAN cloud must have different IDs. Using the same ID for an FCoE VLAN in a VSAN and a VLAN results in a critical fault and traffic disruption for all vNICs and uplink ports using that FCoE VLAN. Ethernet traffic is dropped on any VLAN with an ID that overlaps with an FCoE VLAN ID.
SUMMARY STEPS
Step 4
1.
UCS-A# scope fc-uplink
2.
UCS-A /fc-uplink # scope vsan vsan-name
3.
UCS-A /fc-uplink/vsan # set fcoe-vlan fcoe-vlan-id
4.
UCS-A /fc-uplink/vsan # commit-buffer
DETAILED STEPS
Step 1
Step 2
Command or Action
UCS-A# scope fc-uplink
Step 3
UCS-A /fc-uplink # scope vsan vsan-name
UCS-A /fc-uplink/vsan # set fcoe-vlan fcoe-vlan-id
UCS-A /fc-uplink/vsan # commit-buffer
Purpose
Enters Fibre Channel uplink mode.
Enters VSAN mode for the specified named VSAN.
Sets the unique identifier assigned to the VLAN used for
Fibre Channel connections.
Commits the transaction to the system configuration.
Example
The following example changes the VLAN ID for the FCoE Native VLAN on a named VSAN called finance to 4000 and commits the transaction:
UCS-A# scope fc-uplink
UCS-A /fc-uplink # scope vsan finance
UCS-A /fc-uplink/vsan # set fcoe-vlan 4000
UCS-A /fc-uplink/vsan* # commit-buffer
UCS-A /fc-uplink/vsan #
84
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
Named VSANs
Changing the VLAN ID for the FCoE Native VLAN for a Storage VSAN
Changing the VLAN ID for the FCoE Native VLAN for a Storage
VSAN
Note FCoE VLANs in the SAN cloud and VLANs in the LAN cloud must have different IDs. Using the same ID for an FCoE VLAN in a VSAN and a VLAN results in a critical fault and traffic disruption for all vNICs and uplink ports using that FCoE VLAN. Ethernet traffic is dropped on any VLAN with an ID that overlaps with an FCoE VLAN ID.
SUMMARY STEPS
1.
UCS-A# scope fc-storage
2.
UCS-A /fc-storage # set fcoe-storage-native-vlan fcoe-id
3.
UCS-A /fc-storage # commit-buffer
DETAILED STEPS
Step 1
Step 2
Step 3
Command or Action
UCS-A# scope fc-storage
Purpose
Enters Fibre Channel storage mode.
UCS-A /fc-storage # set fcoe-storage-native-vlan fcoe-id Sets the unique identifier assigned to the VLAN used for
Fibre Channel connections.
UCS-A /fc-storage # commit-buffer Commits the transaction to the system configuration.
Example
The following example changes the VLAN ID for the FCoE Native VLAN on a storage VSAN called finance to 4000 and commits the transaction:
UCS-A# scope fc-storage
UCS-A /fc-storage # set fcoe-storage-native-vlan 4000
UCS-A /fc-storage* # commit-buffer
UCS-A /fc-storage #
Enabling or Disabling Fibre Channel Uplink Trunking
Note If the fabric interconnects are configured for Fibre Channel end-host mode, enabling Fibre Channel uplink trunking renders all VSANs with an ID in the range from 3840 to 4079 non-operational.
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
85
Named VSANs
Enabling or Disabling Fibre Channel Uplink Trunking
SUMMARY STEPS
1.
UCS-A# scope fc-uplink
2.
UCS-A /fc-uplink # scope fabric { a | b }
3.
UCS-A /fc-uplink/fabric # set uplink-trunking { enabled | disabled }
4.
UCS-A /fc-uplink/fabric # commit-buffer
DETAILED STEPS
Step 1
Step 2
Command or Action
UCS-A# scope fc-uplink
Step 3
Step 4
Purpose
Enters Fibre Channel uplink mode.
UCS-A /fc-uplink # scope fabric { a | b } Enters Fibre Channel uplink mode for the specified fabric.
UCS-A /fc-uplink/fabric # set uplink-trunking { enabled
| disabled }
Enables or disables uplink trunking.
UCS-A /fc-uplink/fabric # commit-buffer Commits the transaction to the system configuration.
Example
The following example enables Fibre Channel uplink trunking for fabric A and commits the transaction:
UCS-A# scope fc-uplink
UCS-A /fc-uplink # scope fabric a
UCS-A /fc-uplink/fabric # set uplink-trunking enabled
UCS-A /fc-uplink/fabric* # commit-buffer
UCS-A /fc-uplink/fabric #
86
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
C H A P T E R
6
SAN Pin Groups
•
•
Configuring a SAN Pin Group, on page 87
•
Configuring a FCoE Pin Group, on page 88
SAN Pin Groups
Cisco UCS uses SAN pin groups to pin Fibre Channel traffic from a vHBA on a server to an uplink Fibre
Channel port on the fabric interconnect. You can use this pinning to manage the distribution of traffic from the servers.
Note In Fibre Channel switch mode, SAN pin groups are irrelevant. Any existing SAN pin groups will be ignored.
To configure pinning for a server, you must include the SAN pin group in a vHBA policy. The vHBA policy is then included in the service profile assigned to that server. All traffic from the vHBA will travel through the I/O module to the specified uplink Fibre Channel port.
You can assign the same pin group to multiple vHBA policies. As a result, you do not need to manually pin the traffic for each vHBA.
Important Changing the target interface for an existing SAN pin group disrupts traffic for all vHBAs which use that pin group. The fabric interconnect performs a log in and log out for the Fibre Channel protocols to re-pin the traffic.
Configuring a SAN Pin Group
In a system with two fabric interconnects, you can associate the pin group with only one fabric interconnect or with both fabric interconnects.
SUMMARY STEPS
1.
UCS-A# scope fc-uplink
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
87
SAN Pin Groups
Configuring a FCoE Pin Group
DETAILED STEPS
Step 1
Step 2
Command or Action
UCS-A# scope fc-uplink
Step 3
Purpose
Enters Fibre Channel uplink mode.
UCS-A /fc-uplink # create pin-group pin-group-name Creates a Fibre Channel (SAN) pin group with the specified name, and enters Fibre Channel uplink pin group mode.
(Optional) UCS-A /fc-uplink/pin-group # set descr description
Provides a description for the pin group.
Note If your description includes spaces, special characters, or punctuation, you must begin and end your description with quotation marks. The quotation marks will not appear in the description field of any show command output.
Step 4
2.
UCS-A /fc-uplink # create pin-group pin-group-name
3.
(Optional) UCS-A /fc-uplink/pin-group # set descr description
4.
(Optional) UCS-A /fc-uplink/pin-group # set target { a | b | dual } port slot-num / port-num
5.
UCS-A /fc-uplink/pin-group # commit-buffer
Step 5
(Optional) UCS-A /fc-uplink/pin-group # set target { a | b | dual } port slot-num / port-num
Sets the Fibre Channel pin target to the specified fabric and port.
UCS-A /fc-uplink/pin-group # commit-buffer Commits the transaction to the system configuration.
Example
The following example creates a SAN pin group named fcpingroup12, provides a description for the pin group, sets the pin group target to slot 2, port 1, and commits the transaction:
UCS-A# scope fc-uplink
UCS-A /fc-uplink # create pin-group fcpingroup12
UCS-A /fc-uplink/pin-group* # set descr "This is my pin group #12"
UCS-A /fc-uplink/pin-group* # set target a port 2/1
UCS-A /fc-uplink/pin-group* # commit-buffer
UCS-A /fc-uplink/pin-group #
What to do next
Include the pin group in a vHBA template.
Configuring a FCoE Pin Group
You can create a FCoE pin group, and specify the FCoE uplink port as the pin group target.
SUMMARY STEPS
1.
UCS-A# scope fc-uplink
2.
UCS-A /fc-uplink # create pin-group fcoepingroup
88
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
SAN Pin Groups
Configuring a FCoE Pin Group
3.
UCS-A /fc-uplink/pin-group # set target a fcoe-port 1/8
4.
UCS-A /fc-uplink/pin-group # commit-buffer
DETAILED STEPS
Step 1
Step 2
Command or Action
UCS-A# scope fc-uplink
Step 3
Step 4
Purpose
Enters FC uplink mode.
UCS-A /fc-uplink # create pin-group fcoepingroup Creates a FCoE pin group with the specified name, and enters FCoE uplink pin group mode.
UCS-A /fc-uplink/pin-group # set target a fcoe-port 1/8 Sets FCoE port 1/8 as the target port for this pin group.
UCS-A /fc-uplink/pin-group # commit-buffer Commits the transaction to the system configuration.
Example
UCS-A# scope fc-uplink
UCS-A /fc-uplink # create pin-group fcoepingroup
UCS-A /fc-uplink/pin-group* # set target a fcoe-port 1/8
UCS-A /fc-uplink/pin-group* # commit-buffer
UCS-A /fc-uplink/pin-group #
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
89
Configuring a FCoE Pin Group
SAN Pin Groups
90
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
C H A P T E R
7
FC Identity Assignment
•
Fibre Channel Identity, on page 91
Fibre Channel Identity
A Fibre Channel node and port must have a globally unique World Wide Number (WWN). In Cisco UCS
WWNs are created as identity pools. A Fibre Channel node (a whole server, storage array) must have a World
Wide Node Name (WWNN) and a Fibre Channel port must have a World Wide Port Name (WWPN). Both
WWNNs and WWPNs are physical entities; hence, they have a 64-bit address.
The WWNN pool is created as one large pool for the Cisco UCS domain. You can use the default pool in the
Cisco UCS Manager SAN tab. However, it is recommended to create a custom WWNN pool for that UCS domain.
A communicating device is a node. A host bus adapter in a server constitutes a Fibre Channel node. For servers and hosts, WWNN is unique foe each host bus adapter (HBA). For a SAN switch, the WWNN is common for the chassis. For midrange storage, the WWNN is common for each controller unit. For enterprise storage, the WWNN is unique for the entire array.
Each server has a unique WWPN for each port of the HBA. For a SAN switch, the WWPN is available for each port in the chassis. For storage, each port has an individual.
The FC Identity Tab in Cisco UCS Manager displays the FC Identity of the devices in the Cisco UCS domain
SAN cloud, including the:
• Selected device WWNN or WWPN identifier.
• Whether the identifier is assigned ti a vHBA.
• vHBA to which the identifier is assigned.
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
91
Fibre Channel Identity
FC Identity Assignment
92
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
C H A P T E R
8
WWW Pools
•
•
Creating a WWN Pool, on page 94
•
Deleting a WWN Pool, on page 97
WWN Pools
A World Wide Name (WWN) pool is a collection of WWNs for use by the Fibre Channel vHBAs in a Cisco
UCS domain. You create separate pools for the following:
• WW node names assigned to the vHBA
• WW port names assigned to the vHBA
• Both WW node names and WW port names
Important A WWN pool can include only WWNNs or WWPNs in the ranges from 20:00:00:00:00:00:00:00 to
20:FF:00:FF:FF:FF:FF:FF or from 50:00:00:00:00:00:00:00 to 5F:FF:00:FF:FF:FF:FF:FF. All other WWN ranges are reserved. When fibre channel traffic is sent through the Cisco UCS infrastructure, the source WWPN is converted to a MAC address. You cannot use WWPN pool which can translate to a source multicast MAC address. To ensure the uniqueness of the Cisco UCS WWNNs and WWPNs in the SAN fabric, Cisco recommends using the following WWN prefix for all blocks in a pool: 20:00:00:25:B5:XX:XX:XX
If you use WWN pools in service profiles, you do not have to manually configure the WWNs that will be used by the server associated with the service profile. In a system that implements multi-tenancy, you can use a WWN pool to control the WWNs used by each organization.
You assign WWNs to pools in blocks.
WWNN Pools
A WWNN pool is a WWN pool that contains only WW node names. If you include a pool of WWNNs in a service profile, the associated server is assigned a WWNN from that pool.
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
93
WWW Pools
Creating a WWN Pool
WWPN Pools
A WWPN pool is a WWN pool that contains only WW port names. If you include a pool of WWPNs in a service profile, the port on each vHBA of the associated server is assigned a WWPN from that pool.
WWxN Pools
A WWxN pool is a WWN pool that contains both WW node names and WW port names. You can specify how many ports per node are created with WWxN pools. The pool size must be a multiple of ports-per-node
+ 1. For example, if you specify 7 ports per node, the pool size must be a multiple of 8. If you specify 63 ports per node, the pool size must be a multiple of 64.
You can use a WWxN pool whenever you select a WWNN or WWPN pool. The WWxN pool must be created before it can be assigned.
• For WWNN pools, the WWxN pool is displayed as an option in the WWNN Assignment drop-down list.
• For WWPN pools, choose Derived in the WWPN Assignment drop-down list.
Creating a WWN Pool
Important A WWN pool can include only WWNNs or WWPNs in the ranges from 20:00:00:00:00:00:00:00 to
20:FF:00:FF:FF:FF:FF:FF or from 50:00:00:00:00:00:00:00 to 5F:FF:00:FF:FF:FF:FF:FF. All other WWN ranges are reserved. When fibre channel traffic is sent through the Cisco UCS infrastructure, the source WWPN is converted to a MAC address. You cannot use WWPN pool which can translate to a source multicast MAC address. To ensure the uniqueness of the Cisco UCS WWNNs and WWPNs in the SAN fabric, Cisco recommends using the following WWN prefix for all blocks in a pool: 20:00:00:25:B5:XX:XX:XX
SUMMARY STEPS
1.
UCS-A# scope org org-name
2.
UCS-A /org # create wwn-pool wwn-pool-name { node-and-port-wwn-assignment | node-wwn-assignment | port-wwn-assignment }
3.
(Optional) UCS-A /org/wwn-pool # set descr description
4.
UCS-A /org/wwn-pool # set assignmentorder { default | sequential }
5.
UCS-A /org/wwn-pool # set max-ports-per-node { 15-ports-per-node | 3-ports-per-node |
31-ports-per-node | 63-ports-per-node | 7-ports-per-node }
6.
UCS-A /org/wwn-pool # create block first-wwn last-wwn
7.
UCS-A /org/wwn-pool/block # exit
8.
UCS-A /org/wwn-pool # create initiator wwn wwn
9.
UCS-A /org/wwn-pool/initiator # commit-buffer
94
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
WWW Pools
Creating a WWN Pool
DETAILED STEPS
Step 1
Step 2
Command or Action
UCS-A# scope org org-name
Purpose
Enters the organization mode for the specified organization.
To enter the root organization mode, enter / as the org-name .
UCS-A /org # create wwn-pool wwn-pool-name
{ node-and-port-wwn-assignment | node-wwn-assignment
| port-wwn-assignment }
Creates a WWN pool with the specified name and purpose, and enters organization WWN pool mode. This can be one of the following:
• node-and-port-wwn-assignment —Creates a WWxN pool that includes both world wide node names
(WWNNs) and world wide port names (WWPNs).
• node-wwn-assignment —Creates a WWNN pool that includes only WWNNs.
• port-wwn-assignment —Creates a WWPN pool that includes only WWPNs.
Step 3
This name can be between 1 and 32 alphanumeric characters. You cannot use spaces or any special characters other than - (hyphen), _ (underscore), : (colon), and .
(period), and you cannot change this name after the object is saved.
(Optional) UCS-A /org/wwn-pool # set descr description Provides a description for the WWN pool.
Note If your description includes spaces, special characters, or punctuation, you must begin and end your description with quotation marks. The quotation marks will not appear in the description field of any show command output.
Step 4
Step 5
UCS-A /org/wwn-pool # set assignmentorder { default | sequential }
This can be one of the following:
• default —Cisco UCS Manager selects a random identity from the pool.
• sequential —Cisco UCS Manager selects the lowest available identity from the pool.
UCS-A /org/wwn-pool # set max-ports-per-node
{ 15-ports-per-node | 3-ports-per-node |
31-ports-per-node | 63-ports-per-node |
7-ports-per-node }
For WWxN pools, specify the maximum number of ports that can be assigned to each node name in this pool. The default value is 3-ports-per-node .
Note The pool size for WWxN pools must be a multiple of ports-per-node + 1. For example, if you specify 7-ports-per-node , the pool size must be a multiple of 8. If you specify
63-ports-per-node , the pool size must be a multiple of 64.
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
95
WWW Pools
Creating a WWN Pool
Step 6
Step 7
Step 8
Step 9
Command or Action Purpose
UCS-A /org/wwn-pool # create block first-wwn last-wwn Creates a block (range) of WWNs, and enters organization
WWN pool block mode. You must specify the first and last
WWN in the block using the form
nn:nn:nn:nn:nn:nn:nn:nn , with the WWNs separated by a space.
Note A WWN pool can contain more than one WWN block. To create multiple WWN blocks, you must enter multiple create block commands from organization WWN pool mode.
UCS-A /org/wwn-pool/block # exit
UCS-A /org/wwn-pool # create initiator wwn wwn
Exits organization WWN pool block mode.
Creates a single initiator for a WWNN or WWPN pool, and enters organization WWN pool initiator mode. You must specify the initiator using the form
nn:nn:nn:nn:nn:nn:nn:nn .
Note A WWNN or WWPN pool can contain more than one initiator. To create multiple initiators, you must enter multiple create initiator commands from organization WWN pool mode.
UCS-A /org/wwn-pool/initiator # commit-buffer Commits the transaction to the system configuration.
Example
The following example shows how to create a WWNN pool named sanpool, provide a description for the pool, specify a block of WWNs and an initiator to be used for the pool, and commit the transaction:
UCS-A# scope org /
UCS-A /org # create wwn-pool sanpool node-wwn-assignment
UCS-A /org/wwn-pool* # set descr "This is my WWNN pool"
UCS-A /org/wwn-pool* # create block 20:00:00:25:B5:00:00:00 20:00:00:25:B5:00:00:01
UCS-A /org/wwn-pool/block* # exit
UCS-A /org/wwn-pool* # create initiator 23:00:00:05:AD:1E:02:00
UCS-A /org/wwn-pool/initiator* # commit-buffer
UCS-A /org/wwn-pool/initiator #
The following example shows how to create a WWxN pool named sanpool, provide a description for the pool, specify seven ports per node, specify a block of eight WWNs to be used for the pool, and commit the transaction:
UCS-A# scope org /
UCS-A /org # create wwn-pool sanpool node-and-port-wwn-assignment
UCS-A /org/wwn-pool* # set descr "This is my WWxN pool"
UCS-A /org/wwn-pool* # set max-ports-per-node 7-ports-per-node
UCS-A /org/wwn-pool* # create block 20:00:00:25:B5:00:00:00 20:00:00:25:B5:00:00:08
UCS-A /org/wwn-pool/block* # commit-buffer
UCS-A /org/wwn-pool/block #
96
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
WWW Pools
Deleting a WWN Pool
What to do next
• Include the WWPN pool in a vHBA template.
• Include the WWNN pool in a service profile and template.
• Include the WWxN pool in a service profile and template.
Deleting a WWN Pool
If you delete a pool, Cisco UCS Manager does not reallocate any addresses from that pool that were assigned to vNICs or vHBAs. All assigned addresses from a deleted pool remain with the vNIC or vHBA to which they are assigned until one of the following occurs:
• The associated service profiles are deleted.
• The vNIC or vHBA to which the address is assigned is deleted.
• The vNIC or vHBA is assigned to a different pool.
SUMMARY STEPS
1.
UCS-A# scope org org-name
2.
UCS-A /org # delete wwn-pool pool-name
3.
UCS-A /org # commit-buffer
DETAILED STEPS
Step 1
Command or Action
UCS-A# scope org org-name
Step 2
Step 3
UCS-A /org #
UCS-A /org #
delete wwn-pool pool-name commit-buffer
Purpose
Enters the organization mode for the specified organization.
To enter the root organization mode, enter / as the org-name .
Deletes the specified WWN pool.
Commits the transaction to the system configuration.
Example
The following example shows how to delete the WWN pool named pool4 and commit the transaction:
UCS-A# scope org /
UCS-A /org # delete wwn-pool pool4
UCS-A /org* # commit-buffer
UCS-A /org #
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
97
Deleting a WWN Pool
WWW Pools
98
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
Storage-Related Policies
C H A P T E R
9
•
Configuring vHBA Templates, on page 99
•
Configuring Fibre Channel Adapter Policies, on page 101
•
Configuring the Default vHBA Behavior Policy, on page 107
•
Configuring SAN Connectivity Policies, on page 108
Configuring vHBA Templates
vHBA Template
This template is a policy that defines how a vHBA on a server connects to the SAN. It is also referred to as a vHBA SAN connectivity template.
You must include this policy in a service profile for it to take effect.
Configuring a vHBA Template
SUMMARY STEPS
1.
UCS-A# scope org org-name
2.
UCS-A /org # create vhba-templ vhba-templ-name [ fabric { a | b }] [ fc-if vsan-name ]
3.
(Optional) UCS-A /org/vhba-templ # set descr description
4.
(Optional) UCS-A /org/vhba-templ # set fabric { a | b }
5.
(Optional) UCS-A /org/vhba-templ # set fc-if vsan-name
6.
UCS-A /org/vhba-templ # set max-field-size size-num
7.
UCS-A /org/vhba-templ # set pin-group group-name
8.
UCS-A /org/vhba-templ # set qos-policy mac-pool-name
9.
UCS-A /org/vhba-templ # set stats-policy policy-name
10.
UCS-A /org/vhba-templ # set type { initial-template | updating-template }
11.
UCS-A /org/vhba-templ # set wwpn-pool pool-name
12.
UCS-A /org/vhba-templ # commit-buffer
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
99
Storage-Related Policies
Configuring a vHBA Template
DETAILED STEPS
Step 1
Step 2
Step 3
Step 4
Command or Action
UCS-A# scope org org-name
Purpose
Enters organization mode for the specified organization.
To enter the root organization mode, type / as the org-name .
UCS-A /org # create vhba-templ vhba-templ-name
[ fabric { a | b }] [ fc-if vsan-name ]
Creates a vHBA template and enters organization vHBA template mode.
(Optional) UCS-A /org/vhba-templ # set descr description Provides a description for the vHBA template.
Step 5
(Optional) UCS-A /org/vhba-templ # set fabric { a | b } Specifies the fabric to use for the vHBA. If you did not specify the fabric when creating the vHBA template in
Step 2, then you have the option to specify it with this command.
(Optional) UCS-A /org/vhba-templ # set fc-if vsan-name Specifies the Fibre Channel interface (named VSAN) to use for the vHBA template. If you did not specify the Fibre
Channel interface when creating the vHBA template in
Step 2, you have the option to specify it with this command.
Step 6
Step 7
Step 8
Step 9
Step 10
UCS-A /org/vhba-templ #
UCS-A /org/vhba-templ # updating-template }
set max-field-size size-num set type { initial-template |
Specifies the maximum size of the Fibre Channel frame payload (in bytes) that the vHBA supports.
Specifies the pin group to use for the vHBA template.
UCS-A /org/vhba-templ # set pin-group group-name
UCS-A /org/vhba-templ # set qos-policy mac-pool-name Specifies the QoS policy to use for the vHBA template.
UCS-A /org/vhba-templ # set stats-policy policy-name Specifies the server and server component statistics threshold policy to use for the vHBA template.
Specifies the vHBA template update type. If you do not want vHBA instances created from this template to be automatically updated when the template is updated, use the initial-template keyword; otherwise, use the updating-template keyword to ensure that all vHBA instances are updated when the vHBA template is updated.
Step 11
Step 12
UCS-A /org/vhba-templ # set wwpn-pool pool-name
UCS-A /org/vhba-templ # commit-buffer
Specifies the WWPN pool to use for the vHBA template.
Commits the transaction to the system configuration.
Example
The following example configures a vHBA template and commits the transaction:
UCS-A# scope org /
UCS-A /org* # create vhba template VhbaTempFoo
UCS-A /org/vhba-templ* # set descr "This is a vHBA template example."
UCS-A /org/vhba-templ* # set fabric a
UCS-A /org/vhba-templ* # set fc-if accounting
UCS-A /org/vhba-templ* # set max-field-size 2112
100
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
Storage-Related Policies
Deleting a vHBA Template
UCS-A /org/vhba-templ* # set pin-group FcPinGroup12
UCS-A /org/vhba-templ* # set qos-policy policy34foo
UCS-A /org/vhba-templ* # set stats-policy ServStatsPolicy
UCS-A /org/vhba-templ* # set type updating-template
UCS-A /org/vhba-templ* # set wwpn-pool SanPool7
UCS-A /org/vhba-templ* # commit-buffer
UCS-A /org/vhba-templ #
Deleting a vHBA Template
SUMMARY STEPS
1.
UCS-A# scope org org-name
2.
UCS-A /org # delete vhba-templ vhba-templ-name
3.
UCS-A /org # commit-buffer
DETAILED STEPS
Step 1
Command or Action
UCS-A# scope org org-name
Step 2
Step 3
UCS-A /org #
UCS-A /org # delete vhba-templ commit-buffer vhba-templ-name
Purpose
Enters organization mode for the specified organization.
To enter the root organization mode, type / as the org-name .
Deletes the specified vHBA template.
Commits the transaction to the system configuration.
Example
The following example deletes the vHBA template named VhbaTempFoo and commits the transaction:
UCS-A# scope org /
UCS-A /org # delete vhba template VhbaTempFoo
UCS-A /org* # commit-buffer
UCS-A /org #
Configuring Fibre Channel Adapter Policies
Ethernet and Fibre Channel Adapter Policies
These policies govern the host-side behavior of the adapter, including how the adapter handles traffic. For example, you can use these policies to change default settings for the following:
• Queues
• Interrupt handling
• Performance enhancement
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
101
Storage-Related Policies
Ethernet and Fibre Channel Adapter Policies
• RSS hash
• Failover in a cluster configuration with two fabric interconnects
Note For Fibre Channel adapter policies, the values displayed by Cisco UCS Manager may not match those displayed by applications such as QLogic SANsurfer. For example, the following values may result in an apparent mismatch between SANsurfer and Cisco UCS Manager:
• Max LUNs Per Target—SANsurfer has a maximum of 256 LUNs and does not display more than that number. Cisco UCS Manager supports a higher maximum number of LUNs. This parameter is applicable only for FC-Initiator.
• Link Down Timeout—In SANsurfer, you configure the timeout threshold for link down in seconds. In
Cisco UCS Manager, you configure this value in milliseconds. Therefore, a value of 5500 ms in Cisco
UCS Manager displays as 5s in SANsurfer.
• Max Data Field Size—SANsurfer has allowed values of 512, 1024, and 2048. Cisco UCS Manager allows you to set values of any size. Therefore, a value of 900 in Cisco UCS Manager displays as 512 in SANsurfer.
• LUN Queue Depth—The LUN queue depth setting is available for Windows system FC adapter policies.
Queue depth is the number of commands that the HBA can send and receive in a single transmission per
LUN. Windows Storport driver sets this to a default value of 20 for physical miniports and to 250 for virtual miniports. This setting adjusts the initial queue depth for all LUNs on the adapter. Valid range for this value is 1 - 254. The default LUN queue depth is 20. This feature only works with Cisco UCS
Manager version 3.1(2) and higher. This parameter is applicable only for FC-Initiator.
• IO TimeOut Retry—When the target device does not respond to an IO request within the specified timeout, the FC adapter cancels the pending command then resends the same IO after the timer expires.
The FC adapter valid range for this value is 1 - 59 seconds. The default IO retry timeout is 5 seconds.
This feature only works with Cisco UCS Manager version 3.1(2) and higher.
Operating System Specific Adapter Policies
By default, Cisco UCS provides a set of Ethernet adapter policies and Fibre Channel adapter policies. These policies include the recommended settings for each supported server operating system. Operating systems are sensitive to the settings in these policies. Storage vendors typically require non-default adapter settings. You can find the details of these required settings on the support list provided by those vendors.
Important We recommend that you use the values in these policies for the applicable operating system. Do not modify any of the values in the default policies unless directed to do so by Cisco Technical Support.
However, if you are creating an Ethernet adapter policy for an OS (instead of using the default adapter policy), you must use the following formulas to calculate values that work for that OS.
Depending on the UCS firmware, your driver interrupt calculations may be different. Newer UCS firmware uses a calculation that differs from previous versions. Later driver release versions on Linux operating systems now use a different formula to calculate the Interrupt Count. In this formula, the Interrupt Count is the maximum of either the Transmit Queue or the Receive Queue plus 2.
102
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
Storage-Related Policies
Ethernet and Fibre Channel Adapter Policies
Interrupt Count in Linux Adapter Policies
Drivers on Linux operating systems use differing formulas to calculate the Interrupt Count, depending on the eNIC driver version. The UCS 3.2 release increased the number of Tx and Rx queues for the eNIC driver from 8 to 256 each.
Use one of the following strategies, according to your driver version.
For Linux drivers before the UCS 3.2 firmware release, use the following formula to calculate the Interrupt
Count.
Completion Queues = Transmit Queues + Receive Queues
Interrupt Count = (Completion Queues + 2) rounded up to nearest power of 2
For example, if Transmit Queues = 1 and Receive Queues = 8 then:
Completion Queues = 1 + 8 = 9
Interrupt Count = (9 + 2) rounded up to the nearest power of 2 = 16
On drivers for UCS firmware release 3.2 and higher, the Linux eNIC drivers use the following formula to calculate the Interrupt Count.
Interrupt Count = (#Tx or Rx Queues) + 2
For example:
Interrupt Count wq = 32, rq = 32, cq = 64 - then Interrupt Count = Max(32, 32) + 2 = 34
Interrupt Count wq = 64, rq = 8, cq = 72 – then Interrupt Count = Max(64, 8) + 2 = 66
Interrupt Count wq = 1, rq = 16, cq = 17 - then Interrupt count = Max(1, 16) + 2 = 18
Interrupt Count in Windows Adapter Policies
For Windows OS, the recommended adapter policy in UCS Manager for VIC1400 series adapters is Win-HPN and if RDMA is used, the recommended policy is Win-HPN-SMB. For VIC 1400 series adapters, the recommended interrupt value setting is 512 and the Windows VIC driver takes care of allocating the required number of Interrupts.
For VIC 1300 and VIC 1200 series adapters, the recommended UCS Manager adapter policy is Windows and the Interrupt would be TX + RX + 2, rounded to closest power of 2. The maximum supported Windows queues is 8 for Rx Queues and 1 for Tx Queues.
Example for VIC 1200 and VIC 1300 series adapters:
Tx = 1, Rx = 4, CQ = 5, Interrupt = 8 ( 1 + 4 rounded to nearest power of 2), Enable RSS
Example for VIC 1400 series adapters:
Tx = 1, Rx = 4, CQ = 5, Interrupt = 512 , Enable RSS
NVMe over Fabrics using Fibre Channel
The NVM Express (NVMe) interface allows host software to communicate with a non-volatile memory subsystem. This interface is optimized for Enterprise non-volatile storage, which is typically attached as a register level interface to the PCI Express (PCIe) interface.
NVMe over Fabrics using Fibre Channel (FC-NVMe) defines a mapping protocol for applying the NVMe interface to Fibre Channel. This protocol defines how Fibre Channel services and specified Information Units
(IUs) are used to perform the services defined by NVMe over a Fibre Channel fabric. NVMe initiators can access and transfer information to NVMe targets over Fibre Channel.
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
103
Storage-Related Policies
Configuring a Fibre Channel Adapter Policy
FC-NVMe combines the advantages of Fibre Channel and NVMe. You get the improved performance of
NVMe along with the flexibility and the scalability of the shared storage architecture. Cisco UCS Manager
Release 4.0(2) supports NVMe over Fabrics using Fibre Channel on UCS VIC 14xx adapters.
Cisco UCS Manager provides the recommended FcNVMe adapter policies in the list of pre-configured adapter policies. To create a new FcNVMe adapter policy, follow the steps in the Creating a Fibre Channel Adapter
Policy section.
NVMe over Fabrics Using RDMA
NVMe over Fabrics (NVMeoF) is a communication protocol that allows one computer to access NVMe namespaces available on another computer. NVMeoF is similar to NVMe, but differs in the network-related steps involved in using the NVMeoF storage devices. The commands for discovering, connecting, and disconnecting a NVMeoF storage device are integrated into the nvme utility provided in Linux..
The NVMeoF fabric that Cisco supports is RDMA over Converged Ethernet version 2 (RoCEv2). RoCEv2 is a fabric protocol that runs over UDP. It requires a no-drop policy.
The eNIC RDMA driver works in conjunction with the eNIC driver, which must be loaded first when configuring NVMeoF.
Cisco UCS Manager provides the default Linux-NVMe-RoCE adapter policy for creating NVMe RoCEv2 interfaces. Do not use the default Linux adapter policy. For complete information on configuring RoCEv2 over NVMeoF, refer to the Cisco UCS Manager Configuration Guide for RDMA over Converged Ethernet
(RoCE) v2 .
NVMeoF using RDMA is supported on M5 B-Series or C-Series Servers with Cisco UCS VIC 1400 Series adapters.
Configuring a Fibre Channel Adapter Policy
SUMMARY STEPS
1.
UCS-A# scope org org-name
2.
UCS-A /org # create fc-policy policy-name
3.
(Optional) UCS-A /org/fc-policy # set descr description
4.
(Optional) UCS-A /org/fc-policy # set error-recovery { fcp-error-recovery { disabled | enabled } |
link-down-timeout timeout-msec | port-down-io-retry-count retry-count | port-down-timeout timeout-msec }
5.
(Optional) UCS-A /org/fc-policy # set interrupt mode { intx | msi | msi-x }}
6.
(Optional) UCS-A /org/fc-policy # set port { io-throttle-count throttle-count | max-luns max-num }
7.
(Optional) UCS-A /org/fc-policy # set port-f-logi { retries retry-count | timeout timeout-msec }
8.
(Optional) UCS-A /org/fc-policy # set port-p-logi { retries retry-count | timeout timeout-msec }
9.
(Optional) UCS-A /org/fc-policy # set recv-queue { count count | ring-size size-num }
10.
(Optional) UCS-A /org/fc-policy # set scsi-io { count count | ring-size size-num }
11.
(Optional) UCS-A /org/fc-policy # set trans-queue ring-size size-num }
12.
(Optional) UCS-A /org/fc-policy # set vhbatype mode { fc-initiator | fc-nvme-initiator | fc-nvme-target
| fc-target }
13.
UCS-A /org/fc-policy # commit-buffer
104
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
Storage-Related Policies
Configuring a Fibre Channel Adapter Policy
DETAILED STEPS
Step 1
Step 2
Step 3
Command or Action
UCS-A# scope org org-name
Purpose
Enters organization mode for the specified organization.
To enter the root organization mode, type / as the org-name .
UCS-A /org # create fc-policy policy-name Creates the specified Fibre Channel adapter policy and enters organization Fibre Channel policy mode.
(Optional) UCS-A /org/fc-policy # set descr description Provides a description for the policy.
Note If your description includes spaces, special characters, or punctuation, you must begin and end your description with quotation marks. The quotation marks will not appear in the description field of any show command output.
Step 4
Step 5
Step 6
(Optional) UCS-A /org/fc-policy # set error-recovery
{ fcp-error-recovery { disabled | enabled } |
link-down-timeout timeout-msec |
port-down-io-retry-count retry-count |
port-down-timeout timeout-msec }
(Optional) UCS-A /org/fc-policy # set interrupt mode
{ intx | msi | msi-x }}
(Optional) UCS-A /org/fc-policy # set port
{ io-throttle-count throttle-count | max-luns max-num }
Configures the Fibre Channel error recovery.
Configures the driver interrupt mode.
Configures the Fibre Channel port.
Note The max-luns option is applicable only to the fc-initiator vHBA type.
Step 7
Step 8
Step 9
Step 10
Step 11
Step 12
Step 13
(Optional) UCS-A /org/fc-policy # set port-f-logi { retries retry-count | timeout timeout-msec }
Configures the Fibre Channel port fabric login (FLOGI).
(Optional) UCS-A /org/fc-policy # set port-p-logi { retries retry-count | timeout timeout-msec }
Configures the Fibre Channel port-to-port login (PLOGI).
(Optional) UCS-A /org/fc-policy # set recv-queue { count count | ring-size size-num }
Configures the Fibre Channel receive queue.
Configures the Fibre Channel I/O.
(Optional) UCS-A /org/fc-policy # set scsi-io { count count | ring-size size-num }
(Optional) UCS-A /org/fc-policy # set trans-queue
ring-size size-num }
Configures the Fibre Channel transmit queue.
(Optional) UCS-A /org/fc-policy # set vhbatype mode
{ fc-initiator | fc-nvme-initiator | fc-nvme-target | fc-target }
The vHBA type used in this policy. vHBAs supporting FC and FC-NVMe can now be created on the same adapter.
Note fc-nvme-target and fc-target
Tech Preview options.
are available as
UCS-A /org/fc-policy # commit-buffer Commits the transaction to the system configuration.
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
105
Storage-Related Policies
Deleting a Fibre Channel Adapter Policy
Example
The following example configures a Fibre Channel adapter policy and commits the transaction:
UCS-A# scope org /
UCS-A /org* # create fc-policy FcPolicy42
UCS-A /org/fc-policy* # set descr "This is a Fibre Channel adapter policy example."
UCS-A /org/fc-policy* # set error-recovery error-detect-timeout 2500
UCS-A /org/fc-policy* # set port max-luns 4
UCS-A /org/fc-policy* # set port-f-logi retries 250
UCS-A /org/fc-policy* # set port-p-logi timeout 5000
UCS-A /org/fc-policy* # set recv-queue count 1
UCS-A /org/fc-policy* # set scsi-io ring-size 256
UCS-A /org/fc-policy* # set trans-queue ring-size 256
UCS-A /org/fc-policy* # commit-buffer
UCS-A /org/fc-policy #
The following example configures a Fibre Channel adapter policy with the vHBA type set to FC
NVME Initiator and commits the transaction:
UCS-A# scope org /
UCS-A /org* # create fc-policy FcPolicy42
UCS-A /org/fc-policy* # set descr "This is a Fibre Channel adapter policy example."
UCS-A /org/fc-policy* # set error-recovery error-detect-timeout 2500
UCS-A /org/fc-policy* # set port-f-logi retries 250
UCS-A /org/fc-policy* # set port-p-logi timeout 5000
UCS-A /org/fc-policy* # set recv-queue count 1
UCS-A /org/fc-policy* # set scsi-io ring-size 256
UCS-A /org/fc-policy* # set trans-queue ring-size 256
UCS-A /org/fc-policy* # set vhbatype mode fc-nvme-initiator
UCS-A /org/fc-policy* # commit-buffer
UCS-A /org/fc-policy #
Deleting a Fibre Channel Adapter Policy
SUMMARY STEPS
1.
UCS-A# scope org org-name
2.
UCS-A /org # delete fc-policy policy-name
3.
UCS-A /org # commit-buffer
DETAILED STEPS
Step 1
Command or Action
UCS-A# scope org org-name
Step 2
Step 3
UCS-A /org #
UCS-A /org # delete fc-policy commit-buffer policy-name
Purpose
Enters organization mode for the specified organization.
To enter the root organization mode, type / as the org-name .
Deletes the specified Fibre Channel adapter policy.
Commits the transaction to the system configuration.
106
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
Storage-Related Policies
Configuring the Default vHBA Behavior Policy
Example
The following example deletes the Fibre Channel adapter policy named FcPolicy42 and commits the transaction:
UCS-A# scope org /
UCS-A /org # delete fc-policy FcPolicy42
UCS-A /org* # commit-buffer
UCS-A /org #
Configuring the Default vHBA Behavior Policy
Default vHBA Behavior Policy
Default vHBA behavior policy allow you to configure how vHBAs are created for a service profile. You can choose to create vHBAs manually, or you can allow them to be created automatically.
You can configure the default vHBA behavior policy to define how vHBAs are created. This can be one of the following:
• None —Cisco UCS Manager does not create default vHBAs for a service profile. All vHBAs must be explicitly created.
• HW Inherit —If a service profile requires vHBAs and none have been explicitly defined, Cisco UCS
Manager creates the required vHBAs based on the adapter installed in the server associated with the service profile.
Note If you do not specify a default behavior policy for vHBAs, none is used by default.
Configuring a Default vHBA Behavior Policy
SUMMARY STEPS
1.
UCS-A# scope org /
2.
UCS-A/org # scope vhba-beh-policy
3.
UCS-A/org/vhba-beh-policy # set action { hw-inherit [ template_name name ] | none }
4.
UCS-A/org/vhba-beh-policy # commit-buffer
DETAILED STEPS
Step 1
Step 2
Command or Action
UCS-A# scope org /
UCS-A/org # scope vhba-beh-policy
Purpose
Enters the root organization mode.
Enters default vHBA behavior policy mode.
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
107
Storage-Related Policies
Configuring SAN Connectivity Policies
Step 3
Step 4
Command or Action
UCS-A/org/vhba-beh-policy # set action { hw-inherit
[ template_name name ] | none }
UCS-A/org/vhba-beh-policy # commit-buffer
Purpose
Specifies the default vHBA behavior policy. This can be one of the following:
• hw-inherit —If a service profile requires vHBAs and none have been explicitly defined, Cisco UCS Manager creates the required vHBAs based on the adapter installed in the server associated with the service profile.
If you specify hw-inherit , you can also specify a vHBA template to create the vHBAs.
• none —Cisco UCS Manager does not create default vHBAs for a service profile. All vHBAs must be explicitly created.
Commits the transaction to the system configuration.
Example
This example shows how to set the default vHBA behavior policy to hw-inherit .
UCS-A # scope org /
UCS-A/org # scope vhba-beh-policy
UCS-A/org/vhba-beh-policy # set action hw-inherit
UCS-A/org/vhba-beh-policy* # commit-buffer
UCS-A/org/vhba-beh-policy #
Configuring SAN Connectivity Policies
About the LAN and SAN Connectivity Policies
Connectivity policies determine the connections and the network communication resources between the server and the LAN or SAN on the network. These policies use pools to assign MAC addresses, WWNs, and WWPNs to servers and to identify the vNICs and vHBAs that the servers use to communicate with the network.
Note We do not recommend that you use static IDs in connectivity policies, because these policies are included in service profiles and service profile templates and can be used to configure multiple servers.
Privileges Required for LAN and SAN Connectivity Policies
Connectivity policies enable users without network or storage privileges to create and modify service profiles and service profile templates with network and storage connections. However, users must have the appropriate network and storage privileges to create connectivity policies.
108
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
Storage-Related Policies
Interactions between Service Profiles and Connectivity Policies
Privileges Required to Create Connectivity Policies
Connectivity policies require the same privileges as other network and storage configurations. For example, you must have at least one of the following privileges to create connectivity policies:
• admin—Can create LAN and SAN connectivity policies
• ls-server—Can create LAN and SAN connectivity policies
• ls-network—Can create LAN connectivity policies
• ls-storage—Can create SAN connectivity policies
Privileges Required to Add Connectivity Policies to Service Profiles
After the connectivity policies have been created, a user with ls-compute privileges can include them in a service profile or service profile template. However, a user with only ls-compute privileges cannot create connectivity policies.
Interactions between Service Profiles and Connectivity Policies
You can configure the LAN and SAN connectivity for a service profile through either of the following methods:
• LAN and SAN connectivity policies that are referenced in the service profile
• Local vNICs and vHBAs that are created in the service profile
• Local vNICs and a SAN connectivity policy
• Local vHBAs and a LAN connectivity policy
Cisco UCS maintains mutual exclusivity between connectivity policies and local vNIC and vHBA configuration in the service profile. You cannot have a combination of connectivity policies and locally created vNICs or vHBAs. When you include a LAN connectivity policy in a service profile, all existing vNIC configuration is erased, and when you include a SAN connectivity policy, all existing vHBA configuration in that service profile is erased.
Creating a SAN Connectivity Policy
SUMMARY STEPS
1.
UCS-A# scope org org-name
2.
UCS-A /org # create san-connectivity-policy policy-name
3.
(Optional) UCS-A /org/lan-connectivity-policy # set descr policy-name
4.
UCS-A /org/service-profile # set identity { dynamic-uuid { uuid | derived } | dynamic-wwnn { wwnn | derived } | uuid-pool pool-name | wwnn-pool pool-name }
5.
UCS-A /org/lan-connectivity-policy # commit-buffer
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
109
Storage-Related Policies
Creating a SAN Connectivity Policy
DETAILED STEPS
Step 1
Step 2
Step 3
Command or Action
UCS-A# scope org org-name
Purpose
Enters the organization mode for the specified organization.
To enter the root organization mode, enter / as the org-name .
UCS-A /org # create san-connectivity-policy policy-name Creates the specified SAN connectivity policy, and enters organization network control policy mode.
This name can be between 1 and 16 alphanumeric characters. You cannot use spaces or any special characters other than - (hyphen), _ (underscore), : (colon), and .
(period), and you cannot change this name after the object is saved.
(Optional) UCS-A /org/lan-connectivity-policy # set descr policy-name
Adds a description to the policy. We recommend that you include information about where and how the policy should be used.
Enter up to 256 characters. You can use any characters or spaces except ` (accent mark), \ (backslash), ^ (carat), "
(double quote), = (equal sign), > (greater than), < (less than), or ' (single quote).
Step 4 UCS-A /org/service-profile # set identity { dynamic-uuid
{ uuid | derived } | dynamic-wwnn { wwnn | derived } |
uuid-pool pool-name | wwnn-pool pool-name }
Specifies how the server acquires a UUID or WWNN. You can do one of the following:
• Create a unique UUID in the form nnnnnnnn-nnnn-nnnn-nnnnnnnnnnnn
• Derive the UUID from the one burned into the hardware at manufacture
• Use a UUID pool
• Create a unique WWNN in the form hh : hh : hh
: hh : hh : hh : hh : hh
• Derive the WWNN from one burned into the hardware at manufacture
• Use a WWNN pool
Step 5 UCS-A /org/lan-connectivity-policy # commit-buffer Commits the transaction to the system configuration.
Example
The following example shows how to create a SAN connectivity policy named SanConnect242 and commit the transaction:
UCS-A# scope org /
UCS-A /org* # create san-connectivity-policy SanConnect242
UCS-A /org/san-connectivity-policy* # set descr "SAN connectivity policy"
UCS-A /org/san-connectivity-policy* # set identity wwnn-pool SanPool7
110
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
Storage-Related Policies
Deleting a SAN Connectivity Policy
UCS-A /org/san-connectivity-policy* # commit-buffer
UCS-A /org/san-connectivity-policy #
What to do next
Add one or more vHBAs and/or initiator groups to this SAN connectivity policy.
Deleting a SAN Connectivity Policy
If you delete a SAN connectivity policy that is included in a service profile, it also deletes all vHBAs from that service profile and disrupts SAN data traffic for the server associated with the service profile.
SUMMARY STEPS
Step 2
1.
UCS-A# scope org org-name
2.
UCS-A /org # delete san-connectivity-policy policy-name
3.
UCS-A /org # commit-buffer
DETAILED STEPS
Step 1
Command or Action
UCS-A# scope org org-name
Purpose
Enters the organization mode for the specified organization.
To enter the root organization mode, enter / as the org-name .
Deletes the specified SAN connectivity policy.
Step 3
UCS-A /org # delete san-connectivity-policy policy-name
UCS-A /org # commit-buffer Commits the transaction to the system configuration.
Example
The following example shows how to delete a SAN connectivity policy named SanConnect52 from the root organization and commit the transaction:
UCS-A# scope org /
UCS-A /org # delete san-connectivity-policy SanConnect52
UCS-A /org* # commit-buffer
UCS-A /org #
Creating a vHBA for a SAN Connectivity Policy
If you are continuing from
Creating a SAN Connectivity Policy, on page 109 , begin this procedure at Step 3.
SUMMARY STEPS
1.
UCS-A# scope org org-name
2.
UCS-A /org # scope san-connectivity-policy policy-name
3.
UCS-A /org/san-connectivity-policy # create vhba vhba-name [ fabric { a | b }] [ fc-if fc-if-name ]
4.
UCS-A /org/san-connectivity-policy/vhba # set adapter-policy policy-name
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
111
Storage-Related Policies
Creating a vHBA for a SAN Connectivity Policy
5.
UCS-A /org/san-connectivity-policy/vhba # set identity { dynamic-wwpn { wwpn | derived } |
wwpn-pool wwn-pool-name }
6.
UCS-A /org/san-connectivity-policy/vhba # set max-field-size size-num
7.
UCS-A /org/san-connectivity-policy/vhba # set order { order-num | unspecified }
8.
UCS-A /org/san-connectivity-policy/vhba # set pers-bind { disabled | enabled }
9.
UCS-A /org/san-connectivity-policy/vhba # set pin-group group-name
10.
UCS-A /org/san-connectivity-policy/vhba # set qos-policy policy-name
11.
UCS-A /org/san-connectivity-policy/vhba # set stats-policy policy-name
12.
UCS-A /org/san-connectivity-policy/vhba # set template-name policy-name
13.
UCS-A /org/san-connectivity-policy/vhba # set vcon { 1 | 2 | 3 | 4 | any }
14.
UCS-A /org/san-connectivity-policy/vhba # commit-buffer
DETAILED STEPS
Step 1
Step 2
Step 3
Step 4
Step 5
Command or Action
UCS-A# scope org org-name
Purpose
Enters the organization mode for the specified organization.
To enter the root organization mode, enter / as the org-name .
UCS-A /org # scope san-connectivity-policy policy-name Enters SAN connectivity policy mode for the specified
SAN connectivity policy.
UCS-A /org/san-connectivity-policy # create vhba vhba-name [ fabric { a | b }] [ fc-if fc-if-name ]
Creates a vHBA for the specified SAN connectivity policy and enters vHBA mode.
This name can be between 1 and 16 alphanumeric characters. You cannot use spaces or any special characters other than - (hyphen), _ (underscore), : (colon), and .
(period), and you cannot change this name after the object is saved.
UCS-A /org/san-connectivity-policy/vhba # set
adapter-policy policy-name
Specifies the adapter policy to use for the vHBA.
UCS-A /org/san-connectivity-policy/vhba # set identity
{ dynamic-wwpn { wwpn | derived } | wwpn-pool wwn-pool-name }
Specifies the WWPN for the vHBA.
You can set the storage identity using one of the following options:
• Create a unique WWPN in the form
hh:hh:hh:hh:hh:hh:hh:hh .
You can specify a WWPN in the range from
20:00:00:00:00:00:00:00 to
20:FF:FF:FF:FF:FF:FF:FF or from
50:00:00:00:00:00:00:00 to
5F:FF:FF:FF:FF:FF:FF:FF.
If you want the WWPN to be compatible with Cisco
MDS Fibre Channel switches, use the WWPN template 20:00:00:25:B5:XX:XX:XX .
112
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
Storage-Related Policies
Creating a vHBA for a SAN Connectivity Policy
Step 6
Step 7
Step 8
Step 9
Step 10
Step 11
Step 12
Step 13
Step 14
Command or Action Purpose
• Derive the WWPN from one burned into the hardware at manufacture.
• Assign a WWPN from a WWN pool.
UCS-A /org/san-connectivity-policy/vhba #
max-field-size size-num set Specifies the maximum size of the Fibre Channel frame payload (in bytes) that the vHBA supports.
Enter an integer between 256 and 2112. The default is
2048.
UCS-A /org/san-connectivity-policy/vhba # set order
{ order-num | unspecified }
Specifies the PCI scan order for the vHBA.
UCS-A /org/san-connectivity-policy/vhba # set pers-bind
{ disabled | enabled }
Disables or enables persistent binding to Fibre Channel targets.
UCS-A /org/san-connectivity-policy/vhba # set pin-group group-name
Specifies the SAN pin group to use for the vHBA.
UCS-A /org/san-connectivity-policy/vhba # set qos-policy policy-name
Specifies the QoS policy to use for the vHBA.
UCS-A /org/san-connectivity-policy/vhba # set
stats-policy policy-name
Specifies the statistics threshold policy to use for the vHBA.
UCS-A /org/san-connectivity-policy/vhba # set
template-name policy-name
Specifies the vHBA template to use for the vHBA. If you choose to use a vHBA template for the vHBA, you must still complete all of the configuration not included in the vHBA template, including Steps 4, 7, and 8.
UCS-A /org/san-connectivity-policy/vhba # set vcon { 1
| 2 | 3 | 4 | any }
Assigns the vHBA to one or all virtual network interface connections.
UCS-A /org/san-connectivity-policy/vhba # commit-buffer
Commits the transaction to the system configuration.
Example
The following example shows how to configure a vHBA for a SAN connectivity policy named
SanConnect242 and commit the transaction:
UCS-A# scope org /
UCS-A /org* # scope san-connectivity-policy SanConnect242
UCS-A /org/san-connectivity-policy* # create vhba vhba3 fabric a
UCS-A /org/san-connectivity-policy/vhba* # set adapter-policy AdaptPol2
UCS-A /org/san-connectivity-policy/vhba* # set identity wwpn-pool SanPool7
UCS-A /org/san-connectivity-policy/vhba* # set max-field-size 2112
UCS-A /org/san-connectivity-policy/vhba* # set order 0
UCS-A /org/san-connectivity-policy/vhba* # set pers-bind enabled
UCS-A /org/san-connectivity-policy/vhba* # set pin-group FcPinGroup12
UCS-A /org/san-connectivity-policy/vhba* # set qos-policy QosPol5
UCS-A /org/san-connectivity-policy/vhba* # set stats-policy StatsPol2
UCS-A /org/san-connectivity-policy/vhba* # set template-name SanConnPol3
UCS-A /org/san-connectivity-policy/vhba* # set vcon any
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
113
Storage-Related Policies
Deleting a vHBA from a SAN Connectivity Policy
UCS-A /org/san-connectivity-policy/vhba* # commit-buffer
UCS-A /org/san-connectivity-policy/vhba #
What to do next
If desired, add another vHBA or an initiator group to the SAN connectivity policy. If not, include the policy in a service profile or service profile template.
Deleting a vHBA from a SAN Connectivity Policy
SUMMARY STEPS
1.
UCS-A# scope org org-name
2.
UCS-A /org # scope san-connectivity-policy policy-name
3.
UCS-A /org/san-connectivity-policy # delete vHBA vhba-name
4.
UCS-A /org/san-connectivity-policy # commit-buffer
DETAILED STEPS
Step 1
Step 2
Step 3
Step 4
Command or Action
UCS-A# scope org org-name
Purpose
Enters the organization mode for the specified organization.
To enter the root organization mode, enter / as the org-name .
UCS-A /org # scope san-connectivity-policy policy-name Enters SAN connectivity policy mode for the specified SAN connectivity policy.
UCS-A /org/san-connectivity-policy # vhba-name delete vHBA
UCS-A /org/san-connectivity-policy # commit-buffer
Deletes the specified vHBA from the SAN connectivity policy.
Commits the transaction to the system configuration.
Example
The following example shows how to delete a vHBA named vHBA3 from a SAN connectivity policy named SanConnect242 and commit the transaction:
UCS-A# scope org /
UCS-A /org # scope san-connectivity-policy SanConnect242
UCS-A /org/san-connectivity-policy # delete vHBA vHBA3
UCS-A /org/san-connectivity-policy* # commit-buffer
UCS-A /org/san-connectivity-policy #
Creating an Initiator Group for a SAN Connectivity Policy
If you are continuing from
Creating a SAN Connectivity Policy, on page 109
, begin this procedure at Step 3.
SUMMARY STEPS
1.
UCS-A# scope org org-name
114
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
Storage-Related Policies
Creating an Initiator Group for a SAN Connectivity Policy
2.
UCS-A /org # scope san-connectivity-policy policy-name
3.
UCS-A /org/san-connectivity-policy # create initiator-group group-name fc
4.
UCS-A /org/san-connectivity-policy/initiator-group # create initiator vhba-name
5.
UCS-A /org/san-connectivity-policy/initiator-group # set storage-connection-policy policy-name
6.
UCS-A /org/san-connectivity-policy/initiator-group/storage-connection-def # create storage-target wwpn
7.
UCS-A /org/san-connectivity-policy/initiator-group/storage-connection-def/storage-target # set target-path
{ a | b }
8.
UCS-A /org/san-connectivity-policy/initiator-group/storage-connection-def/storage-target # set target-vsan vsan
9.
UCS-A /org/san-connectivity-policy/initiator-group # commit-buffer
DETAILED STEPS
Step 1
Step 2
Step 3
Step 4
Step 5
Command or Action
UCS-A# scope org org-name
Purpose
Enters the organization mode for the specified organization.
To enter the root organization mode, enter / as the org-name .
UCS-A /org # scope san-connectivity-policy policy-name Enters SAN connectivity policy mode for the specified SAN connectivity policy.
UCS-A /org/san-connectivity-policy # create
initiator-group group-name fc
Creates the specified initiator group for Fibre Channel zoning and enters initiator group mode.
This name can be between 1 and 16 alphanumeric characters. You cannot use spaces or any special characters other than - (hyphen), _ (underscore), : (colon), and .
(period), and you cannot change this name after the object is saved.
UCS-A /org/san-connectivity-policy/initiator-group #
create initiator vhba-name
Creates the specified vHBA initiator in the initiator group.
If desired, repeat this step to add a second vHBA initiator to the group.
UCS-A /org/san-connectivity-policy/initiator-group # set
storage-connection-policy policy-name
Associates the specified storage connection policy with the
SAN connectivity policy.
Note This step assumes that you want to associate an existing storage connection policy to associate with the SAN connectivity policy. If you do, continue with Step 10. If you want to create a local storage definition for this policy instead, continue with Step 6.
Step 6
Step 7
UCS-A
/org/san-connectivity-policy/initiator-group/storage-connection-def
# create storage-target wwpn
Creates a storage target endpoint with the specified WWPN, and enters storage target mode.
UCS-A
/org/san-connectivity-policy/initiator-group/storage-connection-def/storage-target
# set target-path { a | b }
Specifies which fabric interconnect is used for communications with the target endpoint.
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
115
Storage-Related Policies
Creating an SPDM Security Policy
Step 8
Step 9
Command or Action
UCS-A /org/san-connectivity-policy/initiator-group # commit-buffer
Purpose
UCS-A
/org/san-connectivity-policy/initiator-group/storage-connection-def/storage-target
# set target-vsan vsan
Specifies which VSAN is used for communications with the target endpoint.
Commits the transaction to the system configuration.
Example
The following example shows how to configure an initiator group named initGroupZone1 with two initiators for a a SAN connectivity policy named SanConnect242, configure a local storage connection policy definition named scPolicyZone1, and commit the transaction:
UCS-A# scope org /
UCS-A /org* # scope san-connectivity-policy SanConnect242
UCS-A /org/san-connectivity-policy # create initiator-group initGroupZone1 fc
UCS-A /org/san-connectivity-policy/initiator-group* # set zoning-type sist
UCS-A /org/san-connectivity-policy/initiator-group* # create initiator vhba1
UCS-A /org/san-connectivity-policy/initiator-group* # create initiator vhba2
UCS-A /org/san-connectivity-policy/initiator-group* # create storage-connection-def scPolicyZone1
UCS-A /org/san-connectivity-policy/initiator-group/storage-connection-def* # create storage-target
20:10:20:30:40:50:60:70
UCS-A /org/san-connectivity-policy/initiator-group/storage-connection-def/storage-target*
# set target-path a
UCS-A /org/san-connectivity-policy/initiator-group/storage-connection-def/storage-target*
# set target-vsan default
UCS-A /org/san-connectivity-policy/initiator-group* # commit-buffer
UCS-A /org/san-connectivity-policy/initiator-group #
What to do next
If desired, add another initiator group or a vHBA to the SAN connectivity policy. If not, include the policy in a service profile or service profile template.
Creating an SPDM Security Policy
SPDM Security
Cisco UCS M6 Servers can contain mutable components that could provide vectors for attack against a device itself or use of a device to attack another device within the system. To defend against these attacks, the Security
Protocol and Data Model (SPDM) Specification enables a secure transport implementation that challenges a device to prove its identity and the correctness of its mutable component configuration. This feature is supported on Cisco UCS C220 and C240 M6 Servers starting with in Cisco UCS Manager, Release 4.2(1d).
Note SPDM is currently not supported on the Cisco UCS C245 M6 Server.
116
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
Storage-Related Policies
SPDM Authentication
SPDM defines messages, data objects, and sequences for performing message exchanges between devices over a variety of transport and physical media. It orchestrates message exchanges between Baseboard
Management Controllers (BMC) and end-point devices over a Management Component Transport Protocol
(MCTP). Message exchanges include authentication of hardware identities accessing the BMC. The SPDM enables access to low-level security capabilities and operations by specifying a managed level for device authentication, firmware measurement, and certificate management. Endpoint devices are challenged to provide authentication. and BMC authenticates the endpoints and only allows access for trusted entities.
The UCS Manager optionally allows uploads of external security certificates to BMC. A maximum of 40
SPDM certificates is allowed, including native internal certificates. Once the limit is reached, no more certificates can be uploaded. User uploaded certificates can be deleted but internal/default certificates cannot.
A SPDM security policy allows you to specify one of three Security level settings. Security can be set at one of the three levels listed below:
• Full Security:
This is the highest MCTP security setting. When you select this setting, a fault is generated when any endpoint authentication failure or firmware measurement failure is detected. A fault will also be generated if any of the endpoints do not support either endpoint authentication or firmware measurements.
• Partial Security (default):
When you select this setting, a fault is generated when any endpoint authentication failure or firmware measurement failure is detected. There will NOT be a fault generated when the endpoint doesn’t support endpoint authentication or firmware measurements.
• No Security
When you select this setting, there will NOT be a fault generated for any failure (either endpoint measurement or firmware measurement failures).
You can also upload the content of one or more external/device certificates into BMC. Using a SPDM policy allows you to change or delete security certificates or settings as desired. Certificates can be deleted or replaced when no longer needed.
Certificates are listed in all user interfaces on a system.
SPDM Authentication
The Security Protocol and Data Model (SPDM) is used by the BMC for authentication with the storage controller. It requires that the storage controller firmware is secure booted as well as having a Broadcom certificate chain installed in the slot0. During a firmware update, the Broadcom firmware will retain the older measurements for the storage firmware until the OCR or host reboots. If device authentication fails, the firmware will allow only inventory related commands and no set operations can be performed.
Creating a SPDM Security Policy
A Security Protocol and Data Model (SPDM) policy can be created to present security alert-level and certificate contents to BMC for authentication.
• UCS-A# scope org
SUMMARY STEPS
1.
UCS-A# scope org org-name
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
117
Storage-Related Policies
Creating a SPDM Security Policy
2.
UCS-A /org # create spdm-certificate-policy policy-name
3.
UCS-A /org/spdm-certificate-policy* # set fault-alert { full | partial | no }
4.
(Optional) UCS-A /org/spdm-certificate-policy* # set descr description
5.
UCS-A /org/spdm-certificate-policy # commit-buffer
DETAILED STEPS
Step 1
Step 2
Step 3
Step 4
Command or Action
UCS-A# scope org
UCS-A /org # policy-name org-name create spdm-certificate-policy
Purpose
Enters organization mode for the specified organization.
To enter the root organization mode, type / as the org-name .
Creates a SPDM security certificate policy with the specified policy name, and enters organization SPDM certificate policy mode.
UCS-A /org/spdm-certificate-policy* # set fault-alert
{ full | partial | no }
Configures the fault alert level for this policy.
(Optional) UCS-A /org/spdm-certificate-policy* # set descr description
Provides a description for the SPDM security certificate policy.
Note If your description includes spaces, special characters, or punctuation, you must begin and end your description with quotation marks. The quotation marks will not appear in the description field of any show command output.
Step 5 UCS-A /org/spdm-certificate-policy # commit-buffer Commits the transaction to the system configuration.
Example
The following example shows creating a policy called "test" using an alert level of Partial Security
(fault generated when an endpoint authentication or firmware measurement failure is detected). The default policy owner is Local.
UCS-A-FI-A /org #create spdm-certificate-policy test
UCS-A-FI-A /org /spdm-certificate-policy* # set?
fault-alert – Configure fault alert setting desc – Description of policy policy-owner - Change ownership of policies
UCS-A-FI-A /org /spdm-certificate-policy* # set fault-alert partial
UCS-A-FI-A /org/spdm-certificate-policy* #commit-buffer
UCS-A-FI-A /org/spdm-certificate-policy# show details
SPDM Certificate Profile:
Name: test
Fault Alert Setting: partial
Description:
Policy Owner: Local
118
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
Storage-Related Policies
Loading an Outside SPDM Security Certificate Policy
What to do next
Assign outside security certificates, if desired.
Loading an Outside SPDM Security Certificate Policy
The SPDM allows you to download an outside security certificate.
Before you begin
Create a SPDM security certificate policy.
SUMMARY STEPS
1.
UCS-A /org # scope spdm-certificate-policy
2.
UCS-A org/spdm-certificate-policy# create spdm-cert Certificate name
3.
UCS-A /org/spdm-certificate-policy* # set { certificate }
4.
UCS-A /org/spdm-certificate-policy # commit-buffer
DETAILED STEPS
Step 1
Step 2
Command or Action
UCS-A /org # scope spdm-certificate-policy
Step 3
Purpose
Enters SPDM security certificate policy mode.
UCS-A org/spdm-certificate-policy# create spdm-cert
Certificate name
UCS-A /org/spdm-certificate-policy* # set { certificate
}
Creates a SPDM security certificate policy for the specified external certificate,.
Specifying certificate prompts for the content of the outside certificate. The only supported certificate type is pem .
Step 4 UCS-A /org/spdm-certificate-policy # commit-buffer Commits the transaction to the system configuration.
The following example shows loading a certificate for Broadcom of type PEM.
Example
UCS-A-FI-A /org/spdm-certificate-policy# create spdm-cert?
Name – Certificate name
UCS-A-FI-A /org/spdm-certificate-policy# create spdm-cert Broadcom
UCS-A-FI-A /org/spdm-certificate-policy/spdm-cert* # set?
certificate – Certificate content
UCS-A-FI-A /org/spdm-certificate-policy/spdm-cert* # set certificate
{ enter certificate content }
UCS-A-FI-A /org/spdm-certificate-policy/spdm-cert* # commit-buffer
UCS-A-FI-A /org/spdm-certificate-policy/spdm-cert# show detail
SPDM Certificate:
Name: Broadcom
Certificate Type: pem
Certificate Content:
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
119
Storage-Related Policies
Displaying the Security Policy Fault Alert Level
Displaying the Security Policy Fault Alert Level
After the policy is created, you can check the alert level for the SPDM policy.
SUMMARY STEPS
1.
UCS-A /org/spdm-certificate-policy # show fault-alert
DETAILED STEPS
Step 1
Command or Action
UCS-A /org/spdm-certificate-policy # show fault-alert
Example:
UCS-A /server/cimc/spdm-certificate #show fault-alert
Purpose
The returned result shows that the setting for this SPDM policy is Partial, the default.
SPDM Fault Alert Setting: Partial
Viewing the Certificate Inventory
You can view what SPDM certificates have been uploaded and also request further details for a specified certificate.
SUMMARY STEPS
1.
UCS-A # scope server server
2.
UCS-A/server # scope cimc server
3.
UCS-A/server/cimc # scope spdm server
4.
UCS-A/server/cimc/spdm # show certificate
5.
UCS-A/server/cimc/spdm # show certificate certificate-iddetail
6.
UCS-A /org/spdm-certificate-policy/certificate # show
DETAILED STEPS
Step 1
Step 2
Step 3
Step 4
Step 5
Command or Action
UCS-A # scope server server
UCS-A/server # scope cimc server
UCS-A/server/cimc # scope spdm server
UCS-A/server/cimc/spdm # show certificate
UCS-A/server/cimc/spdm # show certificate
certificate-iddetail
Example:
UCS-A /server/cimc/spdm-certificate #show certificate 3 detail
Certificate Information
Certificate Id : 3
Subject Country Code (C)
Subject State (ST)
: US
: Colorado
Purpose
The returned result shows the certificate inventory.
The returned result shows the certificate ID, identifiers, and expiration date.
120
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
Storage-Related Policies
Deleting a SPDM Policy
Command or Action
Subject Organization (O) : Broadcom Inc.
Subject Organization Unit(OU) : NA
Subject Common Name (CN) : NA
Issuer Country Code (C)
Issuer State (ST)
Issuer City (L)
: US
: Colorado
: Colorado Springs
Issuer Organization (O) : Broadcom Inc.
Issuer Organization Unit(OU) : NA
Issuer Common Name (CN)
Valid From
2019 GMT
: NA
: Oct 23 00:25:13
Valid To
GMT
: Apr 8 10:36:14 2021
UserUploaded : Yes
Certificate Content : <Certificate String>
Certificate Type : PEM
Purpose
Step 6 UCS-A /org/spdm-certificate-policy/certificate # show
Example:
SPDM Certificate:
Name SPDM Certificate Type
-----------------------------------------
The returned result shows the type of certificate details.
The returned result shows the fault alert setting.
cert1 Pem
Example:
UCS-A /server/cimc/spdm-certificate/certificate
#up
UCS-A /server/cimc/spdm-certificate #show
SPDM Certificate Policy:
Name Fault Alert Setting
-----------------------------------------
Broadcom Full
Deleting a SPDM Policy
SUMMARY STEPS
DETAILED STEPS
Step 1
Command or Action
UCS-A# scope org org-name
Step 2
1.
UCS-A# scope org org-name
2.
UCS-A /org # delete spdm-certificate-policy policy-name
3.
UCS-A /org # commit-buffer
UCS-A /org # policy-name delete spdm-certificate-policy
Purpose
Enters organization mode for the specified organization.
To enter the root organization mode, type / as the org-name.
Deletes the specified SPDM control policy.
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
121
Storage-Related Policies
Deleting an Initiator Group from a SAN Connectivity Policy
Step 3
Command or Action
UCS-A /org # commit-buffer
Purpose
Commits the transaction to the system configuration.
Example
The following example deletes a power control policy called VendorPolicy2 and commits the transaction:
UCS-A# scope org /
UCS-A /org # delete spdm-certificate-policy VendorPolicy2
UCS-A /org* # commit-buffer
UCS-A /org #
Deleting an Initiator Group from a SAN Connectivity Policy
SUMMARY STEPS
1.
UCS-A# scope org org-name
2.
UCS-A /org # scope san-connectivity-policy policy-name
3.
UCS-A /org/san-connectivity-policy # delete initiator-group group-name
4.
UCS-A /org/san-connectivity-policy # commit-buffer
DETAILED STEPS
Step 1
Step 2
Step 3
Step 4
Command or Action
UCS-A# scope org org-name
Purpose
Enters the organization mode for the specified organization.
To enter the root organization mode, enter / as the org-name .
UCS-A /org # scope san-connectivity-policy policy-name Enters SAN connectivity policy mode for the specified SAN connectivity policy.
UCS-A /org/san-connectivity-policy #
initiator-group group-name
UCS-A /org/san-connectivity-policy # delete commit-buffer
Deletes the specified initiator group from the SAN connectivity policy.
Commits the transaction to the system configuration.
Example
The following example shows how to delete an initiator group named initGroup3 from a SAN connectivity policy named SanConnect242 and commit the transaction:
UCS-A# scope org /
UCS-A /org # scope san-connectivity-policy SanConnect242
UCS-A /org/san-connectivity-policy # delete initiator-group initGroup3
UCS-A /org/san-connectivity-policy* # commit-buffer
UCS-A /org/san-connectivity-policy #
122
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
Storage-Related Policies
Configuring an Aero Controller Storage Profile
Configuring an Aero Controller Storage Profile
Autoconfiguration Mode for Aero Storage Controllers
Cisco UCS C220M6/C240M6 C-series M6 servers support Aero PCIe SAS316-port storage controllers for
Direct Attached Storage. Aero controllers support an Autoconfiguration mode in which the state of a newly inserted disk is automatically moved to the Unconfigured-good state.
Because of this, you can choose whether or not to use Autoconfiguration by creating a Storage Profile and associating it with the server. The default is that the automatic configuration feature is disabled, which retains the drive state when the server is rebooted.
If Autoconfiguration is used, you must select a drive state from one of the following:
• unconfigured-good
• JBOD
• raid0-writeback
This is because the Aero firmware changes the behavior of systemPD to EPD-PT. EPD-PT is internally a
RAID0 volume without any drive DDF metadata. The controller stores the metadata for identifying it as a
RAID0 volume. The EPD-PT drives are considered as JBOD drives so the drive status is reported as JBOD and online.
The table below shows the behavior of Autoconfiguration in different scenarios.
Autoconfig Mode Reboot/OCR Hotplug User Action unconfigured-good (OFF) • All UG drives remain UG.
• All previously configured EPD remain EPD.
• Inserted drive remains UG
• EPD from a different server remains UG on this controller.
Disabling Autoconfig has no impact on the existing configuration jbod (EPD-PT) raid0-writeback (RAID0
WB)
• All UG are converted to EPD.
• Any UG will remain
UG until next boot.
Inserted device converted to EPD.
All UG drives on the controller while running
Autoconfig will be converted to EPD.
• During boot, UG is converted to UPD.
• All UG converted to
RAID0 WB.
• Any UG will remain
UG across control boot.
Inserted device converted to RAID0 WB.
All UG drives on the controller while running
Autoconfig will be converted to RAID0 WB.
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
123
Storage-Related Policies
Creating an Autoconfiguation Profile
Selecting EPD-PT (JBOD) as the default configuration does not retain the unconfigured-good state across host reboot. The drive state can be retained by disabling the automatic configuration feature. If the Autoconfig option is used, the default automatic configuration will always mark a drive as unconfigured-good.
When Autoconfig is selected, then the drive is configured to the desired drive state, the JBOD and unconfigured drives will set the drive state accordingly on the next controller boot or OCR,
The following table shows sample use cases for different Autoconfig scenarios.
Use Case Scenario
Using the server for JBOD Only (for example:
Hyper converged, Hadoop data node etc )
Autoconfig Option jbod
Using the server for RAID volume (for example:
SAP HANA database) unconfigured-good
Using the server for Mixed JBOD and RAID volume unconfigured-good
Using the server for per drive R0 WB (for example:
Hadoop data node) raid0-writeback
Creating an Autoconfiguation Profile
You can include the storage Autoconfiguration (Auto Config) mode option in your storage profile and unconfigure it when no longer needed. Changes will take effect on the next system boot. Auto Config for storage is only available on Cisco UCS M6 servers with Aero controllers.
SUMMARY STEPS
1.
UCS-A# scope org org-name
2.
UCS-A/org# scope storage-profile profile-name
3.
UCS-A/org/storage-profile# show detail expand
4.
UCS-A/org/storage-profile# set auto-config-mode jbod | raid-0 | unconfigured-good | unspecified
5.
UCS-A/org/storage-profile# commit-buffer
DETAILED STEPS
Step 1
Command or Action
UCS-A# scope org org-name
Step 2
Step 3
UCS-A/org# scope storage-profile profile-name
UCS-A/org/storage-profile# show detail expand
Purpose
Enters organization mode for the specified organization.
To enter the root organization mode, type / as the org-name .
Enters the storage profile for the specified profile.
Shows a detailed view of the Storage Profile. If Auto Config
Mode has not been enabled for this storage profile, or no
Aero controller is present, you should not see an entry for
Auto Config Mode. If Auto Config is not configured, inserted devices will retain their state on system reboot.
124
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
Storage-Related Policies
Creating an Autoconfiguation Profile
Step 4
Step 5
Command or Action Purpose
UCS-A/org/storage-profile# set auto-config-mode jbod | raid-0 | unconfigured-good | unspecified
Enables Auto Config Mode and sets the disk configuration mode to the desired state. If no further parameters are specified, all inserted devices will be tagged as
Unconfigured Good on reboot. Enter unconfigured if you wish to disable Auto Config mode.
UCS-A/org/storage-profile# commit-buffer Commits the transaction to the system configuration.
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
125
Creating an Autoconfiguation Profile
Storage-Related Policies
126
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
C H A P T E R
10
Storage Profiles
•
•
Cisco Boot Optimized M.2 RAID Controller, on page 128
•
Disk Groups and Disk Group Configuration Policies, on page 128
•
•
Automatic Disk Selection, on page 132
•
Supported LUN Modifications, on page 133
•
Unsupported LUN Modifications, on page 133
•
Disk Insertion Handling, on page 133
•
Virtual Drive Naming, on page 135
•
LUN Dereferencing, on page 136
•
Controller Constraints and Limitations, on page 136
•
Configuring Storage Profiles, on page 138
Storage Profiles
To allow flexibility in defining the number of storage disks, roles and usage of these disks, and other storage parameters, you can create and use storage profiles. A storage profile encapsulates the storage requirements for one or more service profiles. LUNs configured in a storage profile can be used as boot LUNs or data
LUNs, and can be dedicated to a specific server. You can also specify a local LUN as a boot device. However,
LUN resizing is not supported. The introduction of storage profiles allows you to do the following:
• Configure multiple virtual drives and select the physical drives that are used by a virtual drive. You can also configure the storage capacity of a virtual drive.
• Configure the number, type and role of disks in a disk group.
• Associate a storage profile with a service profile.
You can create a storage profile both at an org level and at a service-profile level. A service profile can have a dedicated storage profile as well as a storage profile at an org level.
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
127
Storage Profiles
Cisco Boot Optimized M.2 RAID Controller
Cisco Boot Optimized M.2 RAID Controller
Beginning with 4.0(4a), Cisco UCS Manager supports Cisco boot optimized M.2 RAID controller
®
(UCS-M2-HWRAID), which is based on Marvell 88SE92xx PCIe to SATA 6Gb/s controller. It is supported on the following servers:
• Cisco UCS C245 M6 Server
• Cisco UCS C220 M6 Server
• Cisco UCS C240 M6 Server
• Cisco UCS C220 M5 Server
• Cisco UCS C240 M5 Server
• Cisco UCS C480 M5 Server
• Cisco UCS B200 M5 Server
• Cisco UCS B480 M5 Server
The following M.2 drives are managed by the Cisco boot optimized M.2 RAID controller:
• 240GB M.2 6G SATA SSD
• 960GB M.2 6G SATA SSD
The Cisco boot optimized M.2 RAID controller supports only RAID1/JBOD (default - JBOD) mode and only
UEFI boot mode.
Limitations of Cisco boot optimized M.2 RAID controller
• Existing LUN migration is not supported.
• Local Disk Configuration policy is not supported.
• The number of LUNs that can be created is limited to one because creating a single LUN uses the entire disk capacity.
• LUN is created using the Local LUN tab (see ) under storage profile and not using the controller definitions.
• You cannot mix different capacity M.2 drives.
• You cannot rename an orphan virtual drive on a blade or a rack server.
Disk Groups and Disk Group Configuration Policies
You can select and configure the disks to be used for storage. A logical collection of these physical disks is called a disk group. Disk groups allow you to organize local disks. The storage controller controls the creation and configuration of disk groups.
128
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
Storage Profiles
Virtual Drives
A disk group configuration policy defines how a disk group is created and configured. The policy specifies the RAID level to be used for the disk group. It also specifies either a manual or an automatic selection of disks for the disk group, and roles for disks. You can use a disk group policy to manage multiple disk groups.
However, a single disk group can be managed only by one disk group policy.
A hot spare is an unused extra disk that can be used by a disk group in the case of failure of a disk in the disk group. Hot spares can be used only in disk groups that support a fault-tolerant RAID level.
Virtual Drives
A disk group can be partitioned into virtual drives. Each virtual drive appears as an individual physical device to the Operating System.
All virtual drives in a disk group must be managed by using a single disk group policy.
Configuration States
Indicates the configuration states of a virtual drive. Virtual drives can have the following configuration states:
• Applying—Creation of the virtual drive is in progress.
• Applied—Creation of the virtual drive is complete, or virtual disk policy changes are configured and applied successfully.
• Failed to apply—Creation, deletion, or renaming of a virtual drive has failed due to errors in the underlying storage subsystem.
• Orphaned—The service profile that contained this virtual drive is deleted or the service profile is no longer associated with a storage profile.
Note Orphaned LUNs cannot be used for booting OS. Although an image can be installed on these LUNs, booting from these drives will fail. To use any specific orphaned LUN, you must reassociate the storage profile, which will return it to the “Equipped” presence state.
• Not in use—The service profile that contained this virtual drive is in the disassociated state.
Deployment States
Indicates the actions that you are performing on virtual drives. Virtual drives can have the following deployment states:
• No action—No pending work items for the virtual drive.
• Creating—Creation of the virtual drive is in progress.
• Deleting—Deletion of the virtual drive is in progress.
• Modifying—Modification of the virtual drive is in progress.
• Apply-Failed—Creation or modification of the virtual drive has failed.
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
129
Storage Profiles
RAID Levels
Operability States
Indicates the operating condition of a virtual drive. Virtual drives can have the following operability states:
• Optimal—The virtual drive operating condition is good. All configured drives are online.
• Degraded—The virtual drive operating condition is not optimal. One of the configured drives has failed or is offline.
• Cache-degraded—The virtual drive has been created with a write policy of write back mode, but the
BBU has failed, or there is no BBU.
Note This state does not occur if you select the always write back mode.
• Partially degraded—The operating condition in a RAID 6 virtual drive is not optimal. One of the configured drives has failed or is offline. RAID 6 can tolerate up to two drive failures.
• Offline—The virtual drive is not available to the RAID controller. This is essentially a failed state.
• Unknown—The state of the virtual drive is not known.
Presence States
Indicates the presence of virtual drive components. Virtual drives have the following presence states:
• Equipped—The virtual drive is available.
• Mismatched—A virtual drive deployed state is different from its configured state.
• Missing—Virtual drive is missing.
RAID Levels
The RAID level of a disk group describes how the data is organized on the disk group for the purpose of ensuring availability, redundancy of data, and I/O performance.
The following are features provided by RAID:
• Striping—Segmenting data across multiple physical devices. This improves performance by increasing throughput due to simultaneous device access.
• Mirroring—Writing the same data to multiple devices to accomplish data redundancy.
• Parity—Storing of redundant data on an additional device for the purpose of error correction in the event of device failure. Parity does not provide full redundancy, but it allows for error recovery in some scenarios.
• Spanning—Allows multiple drives to function like a larger one. For example, four 20 GB drives can be combined to appear as a single 80 GB drive.
The supported RAID levels include the following:
130
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
Storage Profiles
RAID Levels
• Disable Local Storage—(Supported for PCH SSD Controller Definition) This disk policy mode is to disable the SATA AHCI Controller. This mode can be set only when disks are not present under the
SATA AHCI controller. To re-enable this controller and to bring the controller back to its default value
(AHCI), you can select No RAID mode or No Local Storage mode.
• No Local Storage—(Supported for PCH SSD Controller Definition) For a diskless server or a SAN only configuration. If you select this option, you cannot associate any service profile which uses this policy with a server that has a local disk.
• RAID 0 Striped— (Supported for PCH SSD Controller Definition) Data is striped across all disks in the array, providing fast throughput. There is no data redundancy, and all data is lost if any disk fails.
• RAID 1 Mirrored— (Supported for PCH SSD Controller Definition) Data is written to two disks, providing complete data redundancy if one disk fails. The maximum array size is equal to the available space on the smaller of the two drives.
• Any Configuration—(Supported for PCH SSD Controller Definition) For a server configuration that carries forward the local disk configuration without any changes.
• No RAID—(Supported for PCH SSD Controller Definition) Allthe disks can be used individually without interdependency similarto JBOD disks. If you choose No RAID and you apply this policyto a server that already has an operating system with RAID storageconfigured, the system does not remove the disk contents.Therefore, there may be no visible differences on the server afteryou apply the No RAID mode.
This can lead to a mismatchbetween the RAID configuration in the policy and the actual diskconfiguration shown in the Inventory > Storage tab for the server.To make sure that any previous RAID configuration informationis removed from a disk, apply a scrub policy that removes all diskinformation after you apply the No RAID configuration mode.
• RAID 5 Striped Parity— (Not supported for PCH SSD Controller Definition) Data is striped across all disks in the array. Part of the capacity of each disk stores parity information that can be used to reconstruct data if a disk fails. RAID 5 provides good data throughput for applications with high read request rates.
RAID 5 distributes parity data blocks among the disks that are part of a RAID-5 group and requires a minimum of three disks.
• RAID 6 Striped Dual Parity— (Not supported for PCH SSD Controller Definition) Data is striped across all disks in the array and two sets of parity data are used to provide protection against failure of up to two physical disks. In each row of data blocks, two sets of parity data are stored.
Other than addition of a second parity block, RAID 6 is identical to RAID 5 . A minimum of four disks are required for RAID 6.
• RAID 10 Mirrored and Striped— (Not supported for PCH SSD Controller Definition) RAID 10 uses mirrored pairs of disks to provide complete data redundancy and high throughput rates through block-level striping. RAID 10 is mirroring without parity and block-level striping. A minimum of four disks are required for RAID 10.
• RAID 50 Striped Parity and Striped— (Not supported for PCH SSD Controller Definition) Data is striped across multiple striped parity disk sets to provide high throughput and multiple disk failure tolerance.
• RAID 60 Striped Dual Parity and Striped— (Not supported for PCH SSD Controller Definition) Data is striped across multiple striped dual parity disk sets to provide high throughput and greater disk failure tolerance.
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
131
Storage Profiles
Automatic Disk Selection
Note Some Cisco UCS servers require a license for certainRAID configuration options. When Cisco UCS
Managerassociates a service profile containing this local diskpolicy with a server, Cisco UCS Manager verifies thatthe selected RAID option is properly licensed. If thereare issues, Cisco UCS Manager displays a configurationerror during the service profile association. For RAID license information for a specific Cisco
UCSserver, see the Hardware Installation Guide for that server.
Automatic Disk Selection
When you specify a disk group configuration, and do not specify the local disks in it, Cisco UCS Manager determines the disks to be used based on the criteria specified in the disk group configuration policy. Cisco
UCS Manager can make this selection of disks in multiple ways.
When all qualifiers match for a set of disks, then disks are selected sequentially according to their slot number.
Regular disks and dedicated hot spares are selected by using the lowest numbered slot.
The following is the disk selection process:
1.
Iterate over all local LUNs that require the creation of a new virtual drive. Iteration is based on the following criteria, in order: a.
Disk type b.
Minimum disk size from highest to lowest c.
Space required from highest to lowest d.
Disk group qualifier name, in alphabetical order e.
Local LUN name, in alphabetical order
2.
Select regular disks depending on the minimum number of disks and minimum disk size. Disks are selected sequentially starting from the lowest numbered disk slot that satisfies the search criteria.
Note If you specify Any as the type of drive, the first available drive is selected. After this drive is selected, subsequent drives will be of a compatible type. For example, if the first drive was SATA, all subsequent drives would be SATA. Cisco UCS Manager Release 2.5 supports only SATA and SAS.
Cisco UCS Manager Release 2.5 does not support RAID migration.
3.
Select dedicated hot spares by using the same method as normal disks. Disks are only selected if they are in an Unconfigured Good state.
4.
If a provisioned LUN has the same disk group policy as a deployed virtual drive, then try to deploy the new virtual drive in the same disk group. Otherwise, try to find new disks for deployment.
132
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
Storage Profiles
Supported LUN Modifications
Supported LUN Modifications
Some modifications that are made to the LUN configuration when LUNs are already deployed on an associated server are supported.
The following are the types of modifications that can be performed:
• Creation of a new virtual drive.
• Deletion of an existing virtual drive, which is in the orphaned state.
• Non-disruptive changes to an existing virtual drive. These changes can be made on an existing virtual drive without loss of data, and without performance degradation:
• Policy changes. For example, changing the write cache policy.
• Modification of boot parameters
The removal of a LUN will cause a warning to be displayed. Ensure that you take action to avoid loss of data.
Unsupported LUN Modifications
Some modifications to existing LUNs are not possible without destroying the original virtual drive and creating a new one. All data is lost in these types of modification, and these modifications are not supported.
Disruptive modifications to an existing virtual drive are not supported. The following are unsupported disruptive changes:
• Any supported RAID level change that can be handled through reconstruction. For example, RAID0 to
RAID1.
• Increasing the size of a virtual drive through reconstruction.
• Addition and removal of disks through reconstruction.
Destructive modifications are also not supported. The following are unsupported destructive modifications:
• RAID-level changes that do not support reconstruction. For example, RAID5 to RAID1.
• Shrinking the size of a virtual drive.
• RAID-level changes that support reconstruction, but where there are other virtual drives present on the same drive group.
• Disk removal when there is not enough space left on the disk group to accommodate the virtual drive.
• Explicit change in the set of disks used by the virtual drive.
Disk Insertion Handling
When the following sequence of events takes place:
1.
The LUN is created in one of the following ways:
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
133
Storage Profiles
Non-Redundant Virtual Drives a.
You specify the slot specifically by using a local disk reference b.
The system selects the slot based on criteria specified by you
2.
The LUN is successfully deployed, which means that a virtual drive is created, which uses the slot.
3.
You remove a disk from the slot, possibly because the disk failed.
4.
You insert a new working disk into the same slot.
The following scenarios are possible:
•
Non-Redundant Virtual Drives, on page 134
•
Redundant Virtual Drives with No Hot Spare Drives, on page 134
•
Redundant Virtual Drives with Hot Spare Drives, on page 134
•
Replacing Hot Spare Drives, on page 135
•
Inserting Physical Drives into Unused Slots, on page 135
Non-Redundant Virtual Drives
For non-redundant virtual drives (RAID 0), when a physical drive is removed, the state of the virtual drive is
Inoperable . When a new working drive is inserted, the new physical drive goes to an Unconfigured Good state.
For non-redundant virtual drives, there is no way to recover the virtual drive. You must delete the virtual drive and re-create it.
Redundant Virtual Drives with No Hot Spare Drives
For redundant virtual drives (RAID 1, RAID 5, RAID 6, RAID 10, RAID 50, RAID 60) with no hot spare drives assigned, virtual drive mismatch, virtual drive member missing, and local disk missing faults appear until you insert a working physical drive into the same slot from which the old physical drive was removed.
If the physical drive size is greater than or equal to that of the old drive, the storage controller automatically uses the new drive for the virtual drive. The new drive goes into the Rebuilding state. After rebuild is complete, the virtual drive goes back into the Online state.
Redundant Virtual Drives with Hot Spare Drives
For redundant virtual drives (RAID 1, RAID 5, RAID 6, RAID 10, RAID 50, RAID 60) with hot spare drives assigned, when a drive fails, or when you remove a drive, the dedicated hot spare drive, if available, goes into the Rebuilding state with the virtual drive in the Degraded state. After rebuilding is complete, that drive goes to the Online state.
Cisco UCSM raises a disk missing and virtual drive mismatch fault because although the virtual drive is operational, it does not match the physical configuration that Cisco UCSM expects.
if you insert a new disk in the slot with the disk missing, automatic copy back starts from the earlier hot spare disk to the newly inserted disk. After copy back, the hot spare disk is restored. In this state all faults are cleared.
134
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
Storage Profiles
Replacing Hot Spare Drives
If automatic copy back does not start, and the newly inserted disk remains in the Unconfigured Good , JBOD , or Foreign Configuration state, remove the new disk from the slot, reinsert the earlier hot spare disk into the slot, and import foreign configuration. This initiates the rebuilding process and the drive state becomes Online .
Now, insert the new disk in the hot spare slot and mark it as hot spare to match it exactly with the information available in Cisco UCSM.
Replacing Hot Spare Drives
If a hot spare drive is replaced, the new hot spare drive will go to the Unconfigured Good , Unconfigured
Bad , JBOD , or Foreign Configuration state.
Cisco UCSM will raise a virtual drive mismatch or virtual drive member mismatch fault because the hot spare drive is in a state different from the state configured in Cisco UCSM.
You must manually clear the fault. To do this, you must perform the following actions:
1.
Clear the state on the newly inserted drive to Unconfigured Good .
2.
Configure the newly inserted drive as a hot spare drive to match what is expected by Cisco UCSM.
Inserting Physical Drives into Unused Slots
If you insert new physical drives into unused slots, neither the storage controller nor Cisco UCSM will make use of the new drive even if the drive is in the Unconfigured Good state and there are virtual drives that are missing good physical drives.
The drive will simply go into the Unconfigured Good state. To make use of the new drive, you will need to modify or create LUNs to reference the newly inserted drive.
Virtual Drive Naming
When you use UCSM to create a virtual drive, UCSM assigns a unique ID that can be used to reliably identify the virtual drive for further operations. UCSM also provides the flexibility to provide a name to the virtual drive at the time of service profile association. Any virtual drive without a service profile or a server reference is marked as an orphan virtual drive.
In addition to a unique ID, a name is assigned to the drive. Names can be assigned in two ways:
• When configuring a virtual drive, you can explicitly assign a name that can be referenced in storage profiles.
• If you have not preprovisioned a name for the virtual drive, UCSM generates a unique name for the virtual drive.
You can rename an orphan virtual drive drives on a blade or a rack server that are not referenced by any service profile or server.
Note The renaming an orphan virtual drive is not supported on the Cisco boot optimized M.2 Raid controller
(UCS-M2-HWRAID).
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
135
Storage Profiles
LUN Dereferencing
LUN Dereferencing
A LUN is dereferenced when it is no longer used by any service profile. This can occur as part of the following scenarios:
• The LUN is no longer referenced from the storage profile
• The storage profile is no longer referenced from the service profile
• The server is disassociated from the service profile
• The server is decommissioned
When the LUN is no longer referenced, but the server is still associated, re-association occurs.
When the service profile that contained the LUN is disassociated, the LUN state is changed to Not in use .
When the service profile that contained the LUN is deleted, the LUN state is changed to Orphaned .
Controller Constraints and Limitations
• The following table provides the maximum supported virtual drives for servers:
Servers/Storage Controllers
UCSB-MRAID12G-M6
Maximum Virtual Drives
16
UCSC-C220-M6, UCSC-C240-M6
UCSC-C240-M5, UCSC-C480-M5
UCS-S3260-M5, UCSC-C3X60-M4,
UCSC-C3K-M4
UCSC-C240-M4, UCSC-C240-M3,
UCSC-C24-M3
UCSB-MRAID12G
UCS-M2-HWRAID
For all other servers.
16
2
18
32
32
64
24
Note • Storage controllers support the check max feature.
• When servers with multiple storage controllers are managed by the same storage profile, the maximum virtual drives are limited to the maximum value supported by the server.
• UCS-MSTOR-M2 and UCS-MSTOR-SD controllers are not supported on
M6 servers.
136
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
Storage Profiles
Controller Constraints and Limitations
• The maximum supported storage controllers for the Cisco UCS C245 M6 Server C-series server is as follows:
Servers/Storage Controllers
Cisco UCS C245 M6 Server
Maximum Virtual Drives
• Dual UCS C245 M6SX
16 SAS/SATA HDD
• UCS C245 M6SX Plus
28 SAS/SATA HDD
• 2 M.2 2280 Drives on UCS-M2-HWRAID
• Directly Attached NVMe on rear risers(up to
4 NVMe SSD)
• The following table provides the maximum supported storage drives for the Cisco UCS C245 M6 Server
:
Servers/Storage Controllers Maximum Virtual Drives
UCS Cisco UCS C245 M6 x 28 HDD/SDD backplane
Up to 24 x 2.5-inch 12-Gbps Front load HDDs or
SSDs and 4 rear hot-swappable 2.5-inch NVMe drives, Total of 8 ( 4 front +4 rear) NVMe SSDs
Dual UCS C245 M6SX
12 SAS3 drives (12 per controller)
Cisco UCS C245 M6 x 24 HDD/SDD backplane UCS C245 M6SX Plus
24 SAS3 drives
UCS-M2-HWRAID M.2 modules with RAID 0/1 support
Only UCS-M2-HWRAID M.2 module support on
4 Front NVMe and 4 Rear NVMe drives
C245 M6
• In Cisco UCS Manager Release 2.2(4), blade servers do not support drives with a block size of 4K, but rack-mount servers support such drives. If a drive with a block size of 4K is inserted into a blade server, discovery fails and the following error message appears: Unable to get Scsi Device
Information from the system .
• In Cisco UCS Manager Release 3.1(2) and later releases, RAID Controller that does not support Out of band inventory (OOB) in C240 M4, M5, and M6 servers, display Operability as NA and Drive State as
Unknown .
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
137
Storage Profiles
Configuring Storage Profiles
Configuring Storage Profiles
Configuring a Disk Group Policy
You can choose to configure a disk group policy through automatic or manual disk selection. Configuring a disk group involves the following:
1.
Setting the RAID Level, on page 138
2.
Automatically Configuring Disks in a Disk Group, on page 139
or
Manually Configuring Disks in a Disk
Note If you have a setup with the Cisco Boot Optimized M.2 Raid Controller (UCS-M2-HWRAID), then you can configure the disk only manually.
3.
Configuring Virtual Drive Properties, on page 143
Setting the RAID Level
SUMMARY STEPS
1.
UCS-A# scope org org-name
2.
UCS-A /org# create disk-group-config-policy disk-group-name
3.
UCS-A /org/disk-group-config-policy* # set raid-level raid-level
4.
UCS-A /org/disk-group-config-policy* # commit-buffer
DETAILED STEPS
Step 1
Command or Action
UCS-A# scope org org-name
Step 2
Step 3
UCS-A /org# raid-level create disk-group-config-policy disk-group-name
UCS-A /org/disk-group-config-policy* # set raid-level
Purpose
Enters the organization mode for the specified organization.
To enter the root organization mode, enter / as the org-name .
Creates a disk group configuration policy with the specified name and enters disk group configuration policy mode.
Specifies the RAID level for the disk group configuration policy. The RAID levels that you can specify are:
• raid-0-striped
• raid-1-mirrored
• raid-10-mirrored-and-striped
• raid-5-striped-parity
• raid-6-striped-dual-parity
• raid-50-striped-parity-and-striped
138
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
Storage Profiles
Automatically Configuring Disks in a Disk Group
Step 4
Command or Action Purpose
• raid-60-striped-dual-parity-and-striped
Note The Cisco boot optimized M.2 RAID controller
(UCS-M2-HWRAID) supports only RAID1.
UCS-A /org/disk-group-config-policy* # commit-buffer Commits the transaction to the system configuration.
Example
This example shows how to set the RAID level for a disk group configuration policy.
UCS-A# scope org
UCS-A /org # create disk-group-config-policy raid5policy
UCS-A /org/disk-group-config-policy* # set raid-level raid-5-striped-parity
UCS-A /org/disk-group-config-policy* # commit-buffer
What to do next
Automatically or manually configure disks as part of the disk group configuration policy.
Automatically Configuring Disks in a Disk Group
You can allow UCSM to automatically select and configure disks in a disk group.
When you create a disk group with RAID 1 policy and configure four disks for it, a RAID1E configuration is created internally by the storage controller.
If you have a set-up with the Cisco Boot Optimized M.2 Raid Controller (UCS-M2-HWRAID), then go to
Manually Configuring Disks in a Disk Group, on page 141
.
SUMMARY STEPS
1.
UCS-A# scope org org-name
2.
UCS-A /org# enter disk-group-config-policy disk-group-name
3.
UCS-A /org/disk-group-config-policy* # enter disk-group-qual
4.
UCS-A /org/disk-group-config-policy/disk-group-qual* # set drive-type drive-type
5.
UCS-A /org/disk-group-config-policy/disk-group-qual* # set min-drive-size drive-size
6.
UCS-A /org/disk-group-config-policy/disk-group-qual* # set num-ded-hot-spares hot-spare-num
7.
UCS-A /org/disk-group-config-policy/disk-group-qual* # set num-drives drive-num
8.
UCS-A /org/disk-group-config-policy/disk-group-qual* # set num-glob-hot-spares hot-spare-num
9.
UCS-A /org/disk-group-config-policy/disk-group-qual* # set use-remaining-disks { no | yes }
10.
UCS-A /org/disk-group-config-policy/disk-group-qual* # commit-buffer
DETAILED STEPS
Step 1
Command or Action
UCS-A# scope org org-name
Purpose
Enters the organization mode for the specified organization.
To enter the root organization mode, enter / as the org-name .
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
139
Storage Profiles
Automatically Configuring Disks in a Disk Group
Step 2
Step 3
Step 4
Step 5
Step 6
Step 7
Step 8
Command or Action
UCS-A /org# enter disk-group-config-policy disk-group-name
UCS-A /org/disk-group-config-policy* # disk-group-qual enter
Purpose
Enters disk group configuration policy mode for the specified disk group name.
Enters disk group qualification mode. In this mode, UCSM automatically configures disks as part of the specified disk group.
UCS-A /org/disk-group-config-policy/disk-group-qual*
# set drive-type drive-type
Specifies the drive type for the disk group. You can select:
• HDD
• SSD
• Unspecified
Note If you specify Unspecified as the type of drive, the first available drive is selected. After this drive is selected, subsequent drives will be of a compatible type. For example, if the first was
SSD, all subsequent drives would be SSD.
UCS-A /org/disk-group-config-policy/disk-group-qual*
# set min-drive-size drive-size
Specifies the minimum drive size for the disk group. Only disks that match this criteria will be available for selection.
The range for minimum drive size is from 0 to10240 GB.
You can also set the minimum drive size as Unspecified .
If you set the minimum drive size as Unspecified , drives of all sizes will be available for selection.
UCS-A /org/disk-group-config-policy/disk-group-qual*
# set num-ded-hot-spares hot-spare-num
Specifies the number of dedicated hot spares for the disk group.
The range for dedicated hot spares is from 0 to 24 hot spares. You can also set the number of dedicated hot spares as Unspecified . If you set the number of dedicated hot spares as Unspecified , the hot spares will be selected according to the disk selection process.
UCS-A /org/disk-group-config-policy/disk-group-qual*
# set num-drives drive-num
Specifies the number of drives for the disk group.
The range for drives is from 0 to 24 drives for Cisco UCS
C240, C220, C24, and C22 servers. For all other servers, the limit is 16 drives per server.. You can also set the number of drives as Unspecified . If you set the number of drives as Unspecified , the number of drives will be selected according to the disk selection process.
UCS-A /org/disk-group-config-policy/disk-group-qual*
# set num-glob-hot-spares hot-spare-num
Specifies the number of global hot spares for the disk group.
The range for global hot spares is from 0 to 24 hot spares.
You can also set the number of global hot spares as
Unspecified . If you set the number of global hot spares as
140
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
Storage Profiles
Manually Configuring Disks in a Disk Group
Step 9
Step 10
Command or Action Purpose
Unspecified , the global hot spares will be selected according to the disk selection process.
UCS-A /org/disk-group-config-policy/disk-group-qual*
# set use-remaining-disks { no | yes }
Specifies whether the remaining disks in the disk group policy should be used or not.
The default value for this command is no .
UCS-A /org/disk-group-config-policy/disk-group-qual*
# commit-buffer
Commits the transaction to the system configuration.
Example
This example shows how to automatically configure disks for a disk group configuration policy.
UCS-A# scope org
UCS-A /org # enter disk-group-config-policy raid5policy
UCS-A /org/disk-group-config-policy* # enter disk-group-qual
UCS-A /org/disk-group-config-policy/disk-group-qual* # set drive-type hdd
UCS-A /org/disk-group-config-policy/disk-group-qual* # set min-drive-size 1000
UCS-A /org/disk-group-config-policy/disk-group-qual* # set num-ded-hot-spares 2
UCS-A /org/disk-group-config-policy/disk-group-qual* # set num-drives 7
UCS-A /org/disk-group-config-policy/disk-group-qual* # set num-glob-hot-spares 2
UCS-A /org/disk-group-config-policy/disk-group-qual* # set use-remaining-disks no
UCS-A /org/disk-group-config-policy/disk-group-qual* # commit-buffer
UCS-A# scope org
UCS-A /org # enter disk-group-config-policy raid5policy
UCS-A /org/disk-group-config-policy* # enter disk-group-qual
UCS-A /org/disk-group-config-policy/disk-group-qual* # set drive-type ssd
UCS-A /org/disk-group-config-policy/disk-group-qual* # set min-drive-size 1000
UCS-A /org/disk-group-config-policy/disk-group-qual* # set num-ded-hot-spares 2
UCS-A /org/disk-group-config-policy/disk-group-qual* # set num-drives 7
UCS-A /org/disk-group-config-policy/disk-group-qual* # commit-buffer
What to do next
Configure Virtual Drives.
Manually Configuring Disks in a Disk Group
You can manually configure disks for a disk group.
When you create a disk group with RAID 1 policy and configure four disks for it, a RAID 1E configuration is created internally by the storage controller.
Cisco boot optimized M.2 RAID controller (UCS-M2-HWRAID) supports only RAID1.
SUMMARY STEPS
1.
UCS-A# scope org org-name
2.
UCS-A /org# enter disk-group-config-policy disk-group-name
3.
UCS-A /org/disk-group-config-policy* # create local-disk-config-ref slot-num
4.
UCS-A /org/disk-group-config-policy/local-disk-config-ref *# set role role
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
141
Storage Profiles
Manually Configuring Disks in a Disk Group
DETAILED STEPS
Step 1
Command or Action
UCS-A# scope org org-name
Step 2
Step 3
5.
UCS-A /org/disk-group-config-policy/local-disk-config-ref *# set span-id span-id
6.
UCS-A /org/disk-group-config-policy/local-disk-config-ref *# commit-buffer
UCS-A /org# enter disk-group-config-policy disk-group-name
UCS-A /org/disk-group-config-policy* #
local-disk-config-ref slot-num create
Purpose
Enters the organization mode for the specified organization.
To enter the root organization mode, enter / as the org-name .
Enters disk group configuration policy mode for the specified disk group name.
Creates a local disk configuration reference for the specified slot and enters local disk configuration reference mode.
Note M.2 drives typically have Slot IDs = 253, 254.
Step 4 UCS-A /org/disk-group-config-policy/local-disk-config-ref
*# set role role
Specifies the role of the local disk in the disk group. You can select:
• ded-hot-spare: Dedicated hot spare
• glob-hot-spare: Global hot spare
• normal
Note If you have a setup with the Cisco Boot
Optimized M.2 Raid Controller
(UCS-M2-HWRAID), then select normal.
Selecting any other value results in configuration error.
Step 5
Step 6
UCS-A /org/disk-group-config-policy/local-disk-config-ref
*# set span-id span-id
Specifies the ID of the span group to which the disk belongs.
Disks belonging to a single span group can be treated as a single disk with a larger size. The values range from 0 to
8. You can also set the Span ID as Unspecified when spanning information is not required.
Note In Cisco UCS Release 2.5, you can have a maximum of 4 span groups.
Note If you have a setup with the Cisco Boot
Optimized M.2 Raid Controller
(UCS-M2-HWRAID), then this field does not apply. Select the Span ID field as Unspecified .
Selecting any value results in configuration error.
UCS-A /org/disk-group-config-policy/local-disk-config-ref
*# commit-buffer
Commits the transaction to the system configuration.
142
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
Storage Profiles
Configuring Virtual Drive Properties
Example
This example shows how to manually configure disks for a disk group configuration policy.
UCS-A# scope org
UCS-A /org # enter disk-group-config-policy raid5policy
UCS-A /org/disk-group-config-policy* # create local-disk-config-ref 1
UCS-A /org/disk-group-config-policy/local-disk-config-ref *# set role ded-hot-spare
UCS-A /org/disk-group-config-policy/local-disk-config-ref* # set span-id 1
UCS-A /org/disk-group-config-policy/local-disk-config-ref *# commit-buffer
What to do next
Configure Virtual Drive Properties.
Configuring Virtual Drive Properties
All virtual drives in a disk group must be managed by using a single disk group policy.
If you try to associate to a server that does not support these properties, a configuration error will be generated.
Only the following storage controllers support these properties:
• LSI 6G MegaRAID SAS 9266-8i
• LSI 6G MegaRAID SAS 9271-8i
• LSI 6G MegaRAID 9265-8i
• LSI MegaRAID SAS 2208 ROMB
• LSI MegaRAID SAS 9361-8i
For the LSI MegaRAID SAS 2208 ROMB controller, these properties are supported only in the B420-M3 blade server. For the other controllers, these properties are supported in multiple rack servers.
Note If you have a setup with the Cisco Boot Optimized M.2 Raid Controller (UCS-M2-HWRAID), then:
• You can create only one virtual drive
• For strip-size , select 64KB or 32KB . Selecting any other value results in configuration error.
• For access-policy , read-policy , write-cache-policy , io-policy , and drive-cache , select platform-default .
Selecting any other value results in configuration error.
SUMMARY STEPS
1.
UCS-A# scope org org-name
2.
UCS-A /org# scope disk-group-config-policy disk-group-name
3.
UCS-A /org/disk-group-config-policy* # create virtual-drive-def
4.
UCS-A /org/disk-group-config-policy/virtual-drive-def* # set access-policy policy-type
5.
UCS-A /org/disk-group-config-policy/virtual-drive-def* # set drive-cache state
6.
UCS-A /org/disk-group-config-policy/virtual-drive-def* # set io-policy policy-type
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
143
Storage Profiles
Configuring Virtual Drive Properties
7.
UCS-A /org/disk-group-config-policy/virtual-drive-def* # set read-policy policy-type
8.
UCS-A /org/disk-group-config-policy/virtual-drive-def* # set strip-size strip-size
9.
UCS-A /org/disk-group-config-policy/virtual-drive-def* # set write-cache-policy policy-type
10.
UCS-A /org/disk-group-config-policy/virtual-drive-def* # commit-buffer
11.
UCS-A /org/disk-group-config-policy/virtual-drive-def* # show
DETAILED STEPS
Step 1
Step 2
Step 3
Step 4
Command or Action
UCS-A# scope org org-name
UCS-A /org# scope disk-group-config-policy disk-group-name
UCS-A /org/disk-group-config-policy* # virtual-drive-def create
Purpose
Enters the organization mode for the specified organization.
To enter the root organization mode, enter / as the org-name .
Enters disk group configuration policy mode for the specified disk group name.
Creates a virtual drive definition and enters the virtual drive definition mode.
UCS-A /org/disk-group-config-policy/virtual-drive-def*
# set access-policy policy-type
Specifies the access policy. This can be one of the following:
• blocked
• platform-default
• read-only:
• read-write
Step 5 UCS-A /org/disk-group-config-policy/virtual-drive-def*
# set drive-cache state
Specifies the state of the drive cache. This can be one of the following:
• enable
• disable
• no-change
• platform-default
Important In Cisco UCS Release 2.5, the drive cache state cannot be changed. It will remain as platform-default , irrespective of the drive cache state that you select.
Step 6 UCS-A /org/disk-group-config-policy/virtual-drive-def*
# set io-policy policy-type
Specifies the I/O policy. This can be one of the following:
• cached
• direct
• platform-default
144
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
Storage Profiles
Configuring Virtual Drive Properties
Step 7
Step 8
Step 9
Step 10
Step 11
Command or Action
UCS-A /org/disk-group-config-policy/virtual-drive-def*
# set read-policy policy-type
Purpose
Specifies the read policy. This can be one of the following:
• normal
• platform-default
• read-ahead
UCS-A /org/disk-group-config-policy/virtual-drive-def*
# set strip-size strip-size
Specifies the strip size. This can be one of the following:
• 64 KB
• 128 KB
• 256 KB
• 512 KB
• 1024 KB
• platform-default
UCS-A /org/disk-group-config-policy/virtual-drive-def*
# set write-cache-policy policy-type
Specifies the write-cache-policy. This can be one of the following:
• always-write-back
• platform-default
• write-back-good-bbu
• write-through
UCS-A /org/disk-group-config-policy/virtual-drive-def*
# commit-buffer
UCS-A /org/disk-group-config-policy/virtual-drive-def*
# show
Commits the transaction to the system configuration.
Displays the configured virtual drive properties.
Example
This example shows how to configure virtual disk properties:
UCS-A# scope org
UCS-A /org # scope disk-group-config-policy raid0policy
UCS-A /org/disk-group-config-policy # create virtual-drive-def
UCS-A /org/disk-group-config-policy/virtual-drive-def* # set access-policy read-write
UCS-A /org/disk-group-config-policy/virtual-drive-def* # set drive-cache enable
UCS-A /org/disk-group-config-policy/virtual-drive-def* # set io-policy cached
UCS-A /org/disk-group-config-policy/virtual-drive-def* # set read-policy normal
UCS-A /org/disk-group-config-policy/virtual-drive-def* # set strip-size 1024
UCS-A /org/disk-group-config-policy/virtual-drive-def* # set write-cache-policy write-through
UCS-A /org/disk-group-config-policy/virtual-drive-def* # commit-buffer
UCS-A /org/disk-group-config-policy/virtual-drive-def # show
Virtual Drive Def:
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
145
Storage Profiles
Creating a Storage Profile
Strip Size (KB): 1024KB
Access Policy: Read Write
Read Policy: Normal
Configured Write Cache Policy: Write Through
IO Policy: Cached
Drive Cache: Enable
UCS-A /org/disk-group-config-policy/virtual-drive-def #
What to do next
Create a Storage Profile
Creating a Storage Profile
You can create a storage profile at the org level and at the service-profile level.
SUMMARY STEPS
1.
UCS-A# scope org org-name
2.
UCS-A /org # create storage-profile storage-profile-name
3.
UCS-A /org/storage-profile* # commit-buffer
4.
(Optional) UCS-A /org* # enter service-profile service-profile-name
5.
(Optional) UCS-A /org/service-profile* # create storage-profile-def
6.
UCS-A /org/service-profile/storage-profile-def* # commit-buffer
DETAILED STEPS
Step 1
Step 2
Step 3
Step 4
Step 5
Step 6
Command or Action
UCS-A# scope org org-name
Purpose
Enters the organization mode for the specified organization.
To enter the root organization mode, enter / as the org-name .
UCS-A /org # create storage-profile storage-profile-name Creates a storage profile with the specified name at the org level and enters storage-profile configuration mode.
UCS-A /org/storage-profile* # commit-buffer Commits the transaction to the system configuration.
(Optional) UCS-A /org* # enter service-profile service-profile-name
(Optional) UCS-A /org/service-profile* # create storage-profile-def
UCS-A /org/service-profile/storage-profile-def* # commit-buffer
Enters the specified service profile.
Creates a storage profile at the service-profile level.
Commits the transaction to the system configuration.
Example
This example shows how to create a storage profile at the org level.
UCS-A# scope org
UCS-A /org # create storage-profile stp2
UCS-A /org/storage-profile* # commit-buffer
146
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
Storage Profiles
Deleting a Storage Profile
This example shows how to create a storage profile at the service-profile level.
UCS-A# scope org
UCS-A /org* # enter service-profile sp1
UCS-A /org/service-profile* # create storage-profile-def
UCS-A /org/service-profile/storage-profile-def* # commit-buffer
What to do next
Create Local LUNs
Deleting a Storage Profile
You can delete a storage profile that was created at the org level or at the service-profile level.
SUMMARY STEPS
1.
UCS-A# scope org org-name
2.
UCS-A /org # delete storage-profile storage-profile-name
3.
(Optional) UCS-A /org # scope service-profile service-profile-name
4.
(Optional) UCS-A /org/service-profile # delete storage-profile-def
DETAILED STEPS
Step 1
Step 2
Step 3
Step 4
Command or Action
UCS-A# scope org org-name
Purpose
Enters the organization mode for the specified organization.
To enter the root organization mode, enter / as the org-name .
UCS-A /org # delete storage-profile storage-profile-name Deletes the storage profile with the specified name at the org level.
Enters the specified service profile.
(Optional) UCS-A /org # scope service-profile service-profile-name
(Optional) UCS-A /org/service-profile # delete storage-profile-def
Deletes the dedicated storage profile at the service-profile level.
Example
This example shows how to delete a storage profile at the org level.
UCS-A # scope org
UCS-A /org # delete storage-profile stor1
This example shows how to delete a storage profile at the service-profile level.
UCS-A # scope org
UCS-A /org # scope service-profile sp1
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
147
Storage Profiles
Local LUNs
UCS-A /org/service-profile # delete storage-profile-def
Local LUNs
Creating Local LUNs
You can create local LUNs within a storage profile at the org level and within a dedicated storage profile at the service-profile level.
SUMMARY STEPS
1.
UCS-A# scope org org-name
2.
UCS-A /org # enter storage-profile storage-profile-name
3.
UCS-A /org/storage-profile* # create local-lun lun-name
4.
UCS-A /org/storage-profile/local-lun* # set auto-deploy { auto-deploy | no-auto-deploy }
5.
UCS-A /org/storage-profile/local-lun* # set disk-policy-name disk-policy-name
6.
UCS-A /org/storage-profile/local-lun* # set order order-num
7.
UCS-A /org/storage-profile/local-lun* # set expand-to-avail { no | yes }
8.
UCS-A /org/storage-profile/local-lun* # set size size
9.
UCS-A /org/storage-profile/local-lun* # commit-buffer
DETAILED STEPS
Step 1
Step 2
Step 3
Command or Action
UCS-A# scope org org-name
Purpose
Enters the organization mode for the specified organization.
To enter the root organization mode, enter / as the org-name .
UCS-A /org # enter storage-profile storage-profile-name Enters storage-profile mode for the specified storage profile.
UCS-A /org/storage-profile* # create local-lun lun-name Creates a local LUN with the specified name.
Step 4
Step 5
Step 6
Step 7
UCS-A /org/storage-profile/local-lun* # set auto-deploy
{ auto-deploy | no-auto-deploy }
UCS-A /org/storage-profile/local-lun* # set
disk-policy-name disk-policy-name
UCS-A /org/storage-profile/local-lun* # set order order-num
Specifies whether the LUN should be auto-deployed or not.
Specifies the name of the disk policy name for this LUN.
Specifies the order of this LUN. The order can range from
1 to 64. You can also specify that the order should be lowest-available for the system to automatically assign the lowest available order to the LUN.
Multiple LUNs referenced by a storage profile must have unique names and unique orders.
UCS-A /org/storage-profile/local-lun* # set expand-to-avail { no | yes }
Specifies whether the LUN should be expanded to the entire available disk group.
For each service profile, only one LUN can be configured to use this option.
148
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
Storage Profiles
Creating Local LUNs
Step 8
Step 9
Command or Action
UCS-A /org/storage-profile/local-lun* # set size size
Purpose
Specifies the size of this LUN in GB. The size can range from 1 GB to 245760 GB.
Note In a setup with the Cisco boot optimized M.2
Raid controller, you do not have to specify a size.
The system uses the full disk capacity to create the LUN, irrespective of the size specified.
Note You do not need to specify a LUN size while claiming an orphaned LUN.
UCS-A /org/storage-profile/local-lun* # commit-buffer Commits the transaction to the system configuration.
Example
This example shows how to configure a local LUN within a storage profile at the org level.
UCS-A# scope org
UCS-A /org # enter storage-profile stp2
UCS-A /org/storage-profile* # create local-lun lun2
UCS-A /org/storage-profile/local-lun* # set disk-policy-name dpn2
UCS-A /org/storage-profile/local-lun* # set order 2
UCS-A /org/storage-profile/local-lun* # set size 1000
UCS-A /org/storage-profile/local-lun* # commit-buffer
UCS-A# scope org
UCS-A /org # enter storage-profile stp2
UCS-A /org/storage-profile* # create local-lun lun2
UCS-A /org/storage-profile/local-lun* # set auto-deploy no-auto-deploy
UCS-A /org/storage-profile/local-lun* # set disk-policy-name dpn2
UCS-A /org/storage-profile/local-lun* # set expand-to-avail yes
UCS-A /org/storage-profile/local-lun* # set size 1000
UCS-A /org/storage-profile/local-lun* # commit-buffer
This example shows how to configure a local LUN within a dedicated storage profile at the service-profile level.
UCS-A# scope org
UCS-A /org* # enter service-profile stp1
UCS-A /org/service-profile* # enter storage-profile-def
UCS-A /org/service-profile/storage-profile-def # create local-lun lun1
UCS-A /org/service-profile/storage-profile-def/local-lun* # set disk-policy-name dpn1
UCS-A /org/service-profile/storage-profile-def/local-lun* # set order 1
UCS-A /org/service-profile/storage-profile-def/local-lun* # set size 1000
UCS-A /org/service-profile/storage-profile-def/local-lun* # commit-buffer
UCS-A# scope org
UCS-A /org # enter service-profile sp1
UCS-A /org/service-profile* # enter storage-profile-def
UCS-A /org/service-profile/storage-profile-def # create local-lun lun1
UCS-A /org/service-profile/storage-profile-def/local-lun* # set auto-deploy no-auto-deploy
UCS-A /org/service-profile/storage-profile-def/local-lun* # set disk-policy-name dpn1
UCS-A /org/service-profile/storage-profile-def/local-lun* # set expand-to-avail yes
UCS-A /org/service-profile/storage-profile-def/local-lun* # set size 1000
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
149
Storage Profiles
Reordering Local LUNs In a Storage Profile
UCS-A /org/service-profile/storage-profile-def/local-lun* # commit-buffer
What to do next
Associate a Storage Profile with a Service Profile
Reordering Local LUNs In a Storage Profile
You can use the set order command to change the local LUN visibility order to the server. This operation will reboot the server.
SUMMARY STEPS
1.
UCS-A# scope org org-name
2.
UCS-A /org # enter storage-profile storage-profile-name
3.
UCS-A /org/storage-profile # enter local-lun lun-name
4.
UCS-A /org/storage-profile/local-lun* # set disk-policy-name disk-policy-name
5.
UCS-A /org/storage-profile/local-lun # set order order-num
6.
UCS-A /org/storage-profile/local-lun* # set size size
7.
UCS-A /org/storage-profile/local-lun # commit-buffer
DETAILED STEPS
Step 1
Step 2
Step 3
Step 4
Step 5
Step 6
Step 7
Command or Action
UCS-A# scope org org-name
Purpose
Enters the organization mode for the specified organization.
To enter the root organization mode, enter / as the org-name .
UCS-A /org # enter storage-profile storage-profile-name Enters storage-profile mode for the specified storage profile.
UCS-A /org/storage-profile # enter local-lun lun-name Enters local-lun mode for the specified local LUN.
UCS-A /org/storage-profile/local-lun* # set
disk-policy-name disk-policy-name
Specifies the name of the disk policy name for this LUN.
UCS-A /org/storage-profile/local-lun # set order order-num Specifies the order of this LUN. The order can range from
1 to 64. You can also specify that the order should be lowest-available for the system to automatically assign the lowest available order to the LUN.
UCS-A /org/storage-profile/local-lun* # set size size Specifies the size of this LUN in GB. The size can range from 1 GB to 10240 GB.
UCS-A /org/storage-profile/local-lun # commit-buffer Commits the transaction to the system configuration.
Example
This example shows how to reorder a local LUN within a storage profile at the org level.
UCS-A# scope org
UCS-A /org # enter storage-profile stp1
UCS-A /org/storage-profile* # enter local-lun lun1
150
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
Storage Profiles
Deleting Local LUNs In a Storage Profile
UCS-A /org/storage-profile/local-lun* # set disk-policy-name dpn1
UCS-A /org/storage-profile/local-lun* # set order 1
UCS-A /org/storage-profile/local-lun* # set size 10
UCS-A /org/storage-profile/local-lun* # exit
UCS-A /org/storage-profile* # enter local-lun lun2
UCS-A /org/storage-profile/local-lun* # set disk-policy-name dpn2
UCS-A /org/storage-profile/local-lun* # set order 2
UCS-A /org/storage-profile/local-lun* # set size 10
UCS-A /org/storage-profile/local-lun* # exit
UCS-A /org/storage-profile* # commit-buffer
UCS-A /org/storage-profile # show configuration enter storage-profile stp1 enter local-lun lun1 set auto-deploy auto-deploy set disk-policy-name dpn1 set order 1 set size 10 exit enter local-lun lun2 set auto-deploy auto-deploy set disk-policy-name dpn2 set order 2 exit set size 10 exit set descr ""
UCS-A /org/storage-profile # enter local-lun lun1
UCS-A /org/storage-profile/local-lun # set order 2
UCS-A /org/storage-profile/local-lun* # exit
UCS-A /org/storage-profile* # enter local-lun lun2
UCS-A /org/storage-profile/local-lun* # set order 1
UCS-A /org/storage-profile/local-lun* # exit
UCS-A /org/storage-profile* # commit-buffer
UCS-A /org/storage-profile # show configuration enter storage-profile stp1 enter local-lun lun1 set auto-deploy auto-deploy set disk-policy-name dpn1 set order 2 set size 10 exit enter local-lun lun2 set auto-deploy auto-deploy set disk-policy-name dpn2 set order 1 exit exit set size 10 set descr ""
Deleting Local LUNs In a Storage Profile
When a LUN is deleted, the corresponding virtual drive is marked as orphan after the virtual drive reference is removed from the server.
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
151
Storage Profiles
Deleting Local LUNs In a Storage Profile
SUMMARY STEPS
1.
UCS-A# scope org org-name
2.
UCS-A /org # enter storage-profile storage-profile-name
3.
(Optional) UCS-A /org/storage-profile* # show local-lun
4.
UCS-A /org/storage-profile* # delete local-lun lun-name
5.
UCS-A /org/storage-profile* # commit-buffer
DETAILED STEPS
Step 1
Step 2
Step 3
Step 4
Step 5
Command or Action
UCS-A# scope org org-name
Purpose
Enters the organization mode for the specified organization.
To enter the root organization mode, enter / as the org-name .
UCS-A /org # enter storage-profile storage-profile-name Enters storage-profile mode for the specified storage profile.
(Optional) UCS-A /org/storage-profile* # show local-lun Displays the local LUNs in the specified storage profile.
UCS-A /org/storage-profile* # delete local-lun lun-name Deletes the specified LUN.
UCS-A /org/storage-profile* # commit-buffer Commits the transaction to the system configuration.
Example
This example shows how to delete a LUN in a storage profile.
UCS-A # scope org
UCS-A /org # enter storage-profile stp2
UCS-A /org/storage-profile # show local-lun
Local SCSI LUN:
LUN Name Size (GB) Order Disk Policy Name Auto Deploy
---------- ----------- ---------------- ---------------- ----------luna 1 2 raid0 lunb 1 1 raid0
UCS-A /org/storage-profile # delete local-lun luna
UCS-A /org/storage-profile* # commit-buffer
UCS-A /org/storage-profile* # show local-lun
Auto Deploy
Auto Deploy
Local SCSI LUN:
LUN Name Size (GB) Order Disk Policy Name Auto Deploy
---------- ----------- ---------------- ---------------- ----------lunb 1 1 raid0 Auto Deploy
152
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
Storage Profiles
LUN Set
LUN Set
LUN Set
Beginning with release 4.0(2a), Cisco UCS Manager provides the ability to configure a range of disk slots into individual RAID0 LUNs using LUN Set option.
The following guidelines should be considered while creating a LUN Set:
• Only SSD and HDD types of disks are allowed.
• Upto 60 disks are allowed in one range.
• You cannot add the same set of disks in range under two different LUN Set configurations.
• If a disk is set in the disk slot range of LUN Set, then you cannot configure the same disk set in Local
LUN configuration under the same storage policy. Similarly, if a disk is set in Local LUN configuration, then you cannot use the same disk in the disk slot range of LUN Set.
• The server, in which the LUN Set is configured, should support OOB storage operations.
• You cannot configure a Local Disk Policy along with a Storage Policy in the same Service Profile.
• You cannot have the same name for a Local LUN and LUN Set.
• In S-series server PCH controllers, slots 201 and 202 do not support LUN Set.
Limitations of LUN Set
Cisco UCS Manager has the following limitations with LUN Set:
• You cannot claim orphaned Local LUNs into a LUN Set.
• Once created, you cannot modify a LUN Set. You should delete and create a new LUN Set with desired parameters.
• OS boot is not supported from LUN Set.
Creating a LUN Set
You can create a LUN Set within a storage profile at the org level and within a dedicated storage profile at the service-profile level.
SUMMARY STEPS
1.
UCS-A# scope org org-name
2.
UCS-A /org # enter storage-profile storage-profile-name
3.
UCS-A /org/storage-profile* # create lun-set lun-set-name
4.
UCS-A /org/storage-profile/lun-set* # set disk-slot-range disk-slot-range
5.
UCS-A /org/storage-profile/lun-set* # create virtual-drive-def
6.
UCS-A /org/storage-profile/lun-set/virtual-drive-def* # set access-policy { blocked | platform-default
| read-only | read-write }
7.
UCS-A /org/storage-profile/lun-set/virtual-drive-def* # set drive-cache { disable | enable | no-change
| platform-default }
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
153
Storage Profiles
Creating a LUN Set
8.
UCS-A /org/storage-profile/lun-set/virtual-drive-def* # set io-policy { cached | direct | platform-default }
9.
UCS-A /org/storage-profile/lun-set/virtual-drive-def* # set read-policy { normal | platform-default | read-ahead }
10.
UCS-A /org/storage-profile/lun-set/virtual-drive-def* # set security { no | yes }
11.
UCS-A /org/storage-profile/lun-set/virtual-drive-def* # set strip-size { 1024kb | 128kb | 16kb | 256kb
| 32kb | 512kb | 64kb | 8kb | platform-default }
12.
UCS-A /org/storage-profile/lun-set/virtual-drive-def* # set write-cache-policy { always-write-back | platform-default | write-back-good-bbu | write-through }
13.
UCS-A /org/storage-profile/lun-set/virtual-drive-def* # commit-buffer
DETAILED STEPS
Step 1
Step 2
Step 3
Step 4
Step 5
Step 6
Step 7
Step 8
Step 9
Step 10
Step 11
Step 12
Command or Action
UCS-A# scope org org-name
Purpose
Enters the organization mode for the specified organization.
To enter the root organization mode, enter / as the org-name .
UCS-A /org # enter storage-profile storage-profile-name Enters storage-profile mode for the specified storage profile.
UCS-A /org/storage-profile* # create lun-set lun-set-name Creates a LUN Set with the specified name.
UCS-A /org/storage-profile/lun-set* # set disk-slot-range disk-slot-range
Specifies the slot range for the disk.
UCS-A /org/storage-profile/lun-set* # create virtual-drive-def
Enters the virtual drive configuration settings mode.
UCS-A /org/storage-profile/lun-set/virtual-drive-def* # set access-policy { blocked | platform-default | read-only
| read-write }
Specifies the type of access allowed.
UCS-A /org/storage-profile/lun-set/virtual-drive-def* # set drive-cache { disable | enable | no-change | platform-default }
Specifies the type of drive cache.
UCS-A /org/storage-profile/lun-set/virtual-drive-def* # set io-policy { cached | direct | platform-default }
Specifies the type of Input/Output Policy.
UCS-A /org/storage-profile/lun-set/virtual-drive-def* # set read-policy { normal | platform-default | read-ahead }
Specifies the read-ahead cache mode.
Configure this option to secure a virtual drive.
UCS-A /org/storage-profile/lun-set/virtual-drive-def* # set security { no | yes }
UCS-A /org/storage-profile/lun-set/virtual-drive-def* # set strip-size { 1024kb | 128kb | 16kb | 256kb | 32kb |
512kb | 64kb | 8kb | platform-default }
Specifies the portion of the striped data segment that resides on each physical disk.
UCS-A /org/storage-profile/lun-set/virtual-drive-def* # set write-cache-policy { always-write-back | platform-default | write-back-good-bbu | write-through }
Specifies the type of write policy.
154
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
Storage Profiles
Deleting a LUN Set
Step 13
Command or Action
UCS-A /org/storage-profile/lun-set/virtual-drive-def* # commit-buffer
Purpose
Commits the transaction to the system configuration.
Example
The following example creates a LUN set and configure the virtual drive settings:
UCS-A# scope org
UCS-A/org # enter storage-profile stroageprofile1
UCS-A/org/storage-profile # create lun-set lunset1
UCS-A/org/storage-profile/lun-set* # set disk-slot-range 2
UCS-A/org/storage-profile/lun-set* # create virtual-drive-def
UCS-A/org/storage-profile/lun-set/virtual-drive-def* # set access-policy read-write
UCS-A/org/storage-profile/lun-set/virtual-drive-def* # set drive-cache enable
UCS-A/org/storage-profile/lun-set/virtual-drive-def* # set io-policy direct
UCS-A/org/storage-profile/lun-set/virtual-drive-def* # set read-policy read-ahead
UCS-A/org/storage-profile/lun-set/virtual-drive-def* # set security yes
UCS-A/org/storage-profile/lun-set/virtual-drive-def* # set strip-size 512kb
UCS-A/org/storage-profile/lun-set/virtual-drive-def* # set write-cache-policy platform-default
UCS-A/org/storage-profile/lun-set/virtual-drive-def* # commit-buffer
What to do next
Associate the Storage Profile with a Service Profile
Deleting a LUN Set
You can delete a LUN Set within a storage profile at the org level and within a dedicated storage profile at the service-profile level.
SUMMARY STEPS
1.
UCS-A# scope org org-name
2.
UCS-A /org # enter storage-profile storage-profile-name
3.
UCS-A /org/storage-profile* # delete lun-set lun-set-name
4.
UCS-A /org/storage-profile* # commit-buffer
DETAILED STEPS
Step 1
Step 2
Step 3
Step 4
Command or Action
UCS-A# scope org org-name
Purpose
Enters the organization mode for the specified organization.
To enter the root organization mode, enter / as the org-name .
UCS-A /org # enter storage-profile storage-profile-name Enters storage-profile mode for the specified storage profile.
UCS-A /org/storage-profile* # delete lun-set lun-set-name Deletes the LUN Set with the specified name.
UCS-A /org/storage-profile* # commit-buffer Commits the transaction to the system configuration.
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
155
Storage Profiles
Configuring Aero Controllers
Example
The following example deletes a LUN set:
UCS-A# scope org
UCS-A/org # enter storage-profile stroageprofile1
UCS-A/org/storage-profile # delete lun-set lunset1
UCS-A/org/storage-profile* # commit-buffer
Configuring Aero Controllers
Autoconfiguration Mode for Aero Storage Controllers
Cisco UCS C220M6/C240M6 C-series M6 servers support Aero PCIe SAS316-port storage controllers for
Direct Attached Storage. Aero controllers support an Autoconfiguration mode in which the state of a newly inserted disk is automatically moved to the Unconfigured-good state.
Because of this, you can choose whether or not to use Autoconfiguration by creating a Storage Profile and associating it with the server. The default is that the automatic configuration feature is disabled, which retains the drive state when the server is rebooted.
If Autoconfiguration is used, you must select a drive state from one of the following:
• unconfigured-good
• JBOD
• raid0-writeback
This is because the Aero firmware changes the behavior of systemPD to EPD-PT. EPD-PT is internally a
RAID0 volume without any drive DDF metadata. The controller stores the metadata for identifying it as a
RAID0 volume. The EPD-PT drives are considered as JBOD drives so the drive status is reported as JBOD and online.
The table below shows the behavior of Autoconfiguration in different scenarios.
Autoconfig Mode Reboot/OCR Hotplug User Action unconfigured-good (OFF) • All UG drives remain UG.
• All previously configured EPD remain EPD.
• Inserted drive remains UG
• EPD from a different server remains UG on this controller.
Disabling Autoconfig has no impact on the existing configuration jbod (EPD-PT) • All UG are converted to EPD.
• Any UG will remain
UG until next boot.
Inserted device converted to EPD.
All UG drives on the controller while running
Autoconfig will be converted to EPD.
• During boot, UG is converted to UPD.
156
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
Storage Profiles
Creating an Autoconfiguation Profile
Autoconfig Mode raid0-writeback (RAID0
WB)
Reboot/OCR
• All UG converted to
RAID0 WB.
• Any UG will remain
UG across control boot.
Hotplug User Action
Inserted device converted to RAID0 WB.
All UG drives on the controller while running
Autoconfig will be converted to RAID0 WB.
Selecting EPD-PT (JBOD) as the default configuration does not retain the unconfigured-good state across host reboot. The drive state can be retained by disabling the automatic configuration feature. If the Autoconfig option is used, the default automatic configuration will always mark a drive as unconfigured-good.
When Autoconfig is selected, then the drive is configured to the desired drive state, the JBOD and unconfigured drives will set the drive state accordingly on the next controller boot or OCR,
The following table shows sample use cases for different Autoconfig scenarios.
Use Case Scenario
Using the server for JBOD Only (for example:
Hyper converged, Hadoop data node etc )
Autoconfig Option jbod
Using the server for RAID volume (for example:
SAP HANA database) unconfigured-good
Using the server for Mixed JBOD and RAID volume unconfigured-good
Using the server for per drive R0 WB (for example:
Hadoop data node) raid0-writeback
Creating an Autoconfiguation Profile
You can include the storage Autoconfiguration (Auto Config) mode option in your storage profile and unconfigure it when no longer needed. Changes will take effect on the next system boot. Auto Config for storage is only available on Cisco UCS M6 servers with Aero controllers.
SUMMARY STEPS
1.
UCS-A# scope org org-name
2.
UCS-A/org# scope storage-profile profile-name
3.
UCS-A/org/storage-profile# show detail expand
4.
UCS-A/org/storage-profile# set auto-config-mode jbod | raid-0 | unconfigured-good | unspecified
5.
UCS-A/org/storage-profile# commit-buffer
DETAILED STEPS
Step 1
Command or Action
UCS-A# scope org org-name
Purpose
Enters organization mode for the specified organization.
To enter the root organization mode, type / as the org-name .
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
157
Storage Profiles
PCH Controller Definitions
Step 2
Step 3
Step 4
Step 5
Command or Action
UCS-A/org# scope storage-profile profile-name
UCS-A/org/storage-profile# show detail expand
Purpose
Enters the storage profile for the specified profile.
Shows a detailed view of the Storage Profile. If Auto Config
Mode has not been enabled for this storage profile, or no
Aero controller is present, you should not see an entry for
Auto Config Mode. If Auto Config is not configured, inserted devices will retain their state on system reboot.
UCS-A/org/storage-profile# set auto-config-mode jbod | raid-0 | unconfigured-good | unspecified
Enables Auto Config Mode and sets the disk configuration mode to the desired state. If no further parameters are specified, all inserted devices will be tagged as
Unconfigured Good on reboot. Enter unconfigured if you wish to disable Auto Config mode.
UCS-A/org/storage-profile# commit-buffer Commits the transaction to the system configuration.
PCH Controller Definitions
PCH SSD Controller Definition
Cisco UCS Manager Platform Controller Hub (PCH) Solid State Drive (SSD) Controller Definition provides a local storage configuration in storage profiles where you can configure all the disks in a single RAID or in a JBOD disk array.
Note You must re-acknowledge the server if you remove or insert disks managed by the PCH Controller.
The PCH Controller Definition configuration provides the following features:
• Ability to configure a single LUN RAID across two internal SSDs connected to the onboard PCH controller
• A way to configure the controller in two modes: AHCI (JBOD) and SWRAID (RAID).
• Ability to configure the PCH storage device in an Embedded Local LUN and Embedded Local Disk boot policy so precision control for boot order is achieved even with the presence of other bootable local storage devices in the server. Do not use the Local LUN or the Local JBOD options to boot from PCH disks
• Scrub policy support for the internal SSD drives. This is applicable only for the SWRAID mode. This does not apply for the AHCI and NORAID of PCH Controller modes.
See the UCS Manager Server
Management Guide.
• Firmware upgrade support for the internal SSD drives.
• For M4 and below servers, disk firmware upgrade is supported only when the PCH Controller is in
SWRAID mode. It is not supported for AHCI mode.
• For M5 and higher servers, disk firmware upgrade is supported in both SWRAID and AHCI mode
(except Cisco UCS C125 M5 Server, which supports only AHCI mode) .
158
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
Storage Profiles
FCH Controller Configuration
You can configure PCH controller SSDs in a storage profile policy. You can enable or disable protect configuration which saves the LUN configuration even after a service profile disassociation. You choose a controller mode. The PCH controller configuration supports only these two RAID options: RAID0 and RAID1.
Use No RAID configuration option for AHCI mode where all the disks connected to the controller configured as JBOD disks. The configuration deployment happens as part of the storage profile association to a service profile process.
Cisco UCS Manager supports PCH managed internal SSDs in the following M4 servers:
• UCSC-C240-M4L
• UCSC-C240-M4SX
Cisco UCS Manager supports the following PCH managed SSDs on the M.2 card for all M5 and M6 servers
(except Cisco UCS C125 M5 Server):
• 240GB M.2 6G SATA SSD
• 960GB M.2 6G SATA SSD
Note You cannot have software RAID configuration in the controller definition and legacy boot mode configuration in boot policy together in M5 and M6 servers. Only UEFI boot mode is supported with software RAID configuration in the controller definition. This condition is applicable even if the drives are not used as boot drive.
For the PCH Controller Definition configuration in a Cisco UCS Manager boot policy two new devices exist to select: PCH LUN and PCH Disk.
EmbeddedLocalLun represents the boot device in SWRAID mode and
EmbeddedLocalDisk represent the boot devices in AHCI mode.
The system uses the same scrub policy is used to scrub supported SSDs. If the scrub is Yes, configured LUNs are destroyed as part of disassociation or re-discovery. If the scrub is No, configured LUNs are saved during disassociation and re-discovery.
Cisco UCS Manager supports firmware upgrade for the internal SSDs only when the PCH Controller is in
SWRAID mode. It is not supported in AHCI mode.
FCH Controller Configuration
Fusion Controller Hub (FCH) SSD Controller Definition provides a local storage configuration in storage profiles for AMD based Cisco UCS C125 M5 Server. For AMD processor based servers, the PCH controller is referred to as FCH controller. The controller type remains as PCH in the Cisco UCS Manager GUI.
The FCH Controller works the same as PCH Controller except for the following differences:
• FCH is only in AHCI (JBOD) mode.
Note Cisco UCS Manager GUI shows the RAID support as RAID0, RAID1 , however,
Cisco UCS C125 M5 Server supports only AHCI mode.
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
159
Storage Profiles
Creating a Storage Profile PCH Controller Definition
Note You must re-acknowledge the server if you remove or insert disks managed by the PCH Controller.
• There are two FCH controllers:
• First PCH controller manages SATA disks in the front panel (in the absence of a separate PCIe storage controller)
• Second PCH controller manages the M.2 SSDs
Note For Cisco UCS C125 M5 Server, the PCH IDs are 3 and 4.
Note Further information and procedures related to PCH controller in this document are applicable to both Intel and AMD based servers.
Creating a Storage Profile PCH Controller Definition
You can create a PCH controller definition under a storage profile at the org level or at the service profile level.
SUMMARY STEPS
1.
UCS-A# scope org org-name
2.
UCS-A /org # scope storage-profile storage-profile-name
3.
UCS-A /org/storage-profile # create controller-def controller-definition-name
4.
UCS-A /org/storage-profile/controller-def* # create controller-mode-config
5.
UCS-A /org/storage-profile/controller-def/controller-mode-config* # set protect-config { yes | no }
6.
UCS-A /org/storage-profile/controller-def/controller-mode-config* # set raid-mode { any-configuration
| disable-local-storage | no-local-storage | no-raid | raid-0-striped | raid-1-mirrored | raid-5-striped-parity | raid-50--striped-parity-and-striped | raid-6-striped-dual-parity | raid-60-striped-dual-parity-and-striped | raid-10-mirrored-and-striped }
7.
UCS-A /org/storage-profile/controller-def/controller-mode-config* # commit-buffer
DETAILED STEPS
Step 1
Command or Action
UCS-A# scope org org-name
Purpose
Enters the organization mode for the specified organization.
To enter the root organization mode, enter / as the org-name .
160
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
Storage Profiles
Creating a Storage Profile PCH Controller Definition
Step 2
Step 3
Step 4
Step 5
Step 6
Step 7
Command or Action Purpose
Note This task assumes the storage profile is at the org level. If the storage profile is at the service profile level, see the example below for the steps to scope to the storage profile definition under the service profile.
UCS-A /org # scope storage-profile storage-profile-name Enters storage-profile configuration mode for the selected storage profile.
UCS-A /org/storage-profile # create controller-def controller-definition-name
UCS-A /org/storage-profile/controller-def* # create controller-mode-config
Creates a PCH controller definition with the specified name and enters controller-definition configuration mode.
Creates a PCH controller configuration and enters controller-mode configuration mode.
UCS-A
/org/storage-profile/controller-def/controller-mode-config*
# set protect-config { yes | no }
Specifies whether the server retains the configuration in the
PCH controller even if the server is disassociated from the service profile.
UCS-A
/org/storage-profile/controller-def/controller-mode-config*
# set raid-mode { any-configuration | disable-local-storage | no-local-storage | no-raid | raid-0-striped | raid-1-mirrored | raid-5-striped-parity
| raid-50--striped-parity-and-striped | raid-6-striped-dual-parity | raid-60-striped-dual-parity-and-striped | raid-10-mirrored-and-striped }
Specifies the raid mode for the PCH controller.
UCS-A
/org/storage-profile/controller-def/controller-mode-config*
# commit-buffer
Commits the transaction to the system configuration.
Example
This example shows how to add a PCH controller definition called "raid1-controller" with raid mode set to RAID 1 Mirrored to the org-level storage profile named "storage-profile-A".
UCS-A# scope org /
UCS-A /org # scope storage-profile storage-profile-A
UCS-A /org/storage-profile # create controller-def raid1-controller
UCS-A /org/storage-profile/controller-def* # create controller-mode-config
UCS-A /org/storage-profile/controller-def/controller-mode-config* # set protect-config yes
UCS-A /org/storage-profile/controller-def/controller-mode-config* # set raid-mode raid-1-mirrored
UCS-A /org/storage-profile/controller-def/controller-mode-config* # commit buffer
This example shows how to scope to the service profile called "Service-Profile1", create a storage profile, then create a PCH controller definition called "Raid60Ctrlr" within that storage profile. The controller definition has protection mode off and uses RAID 60 Striped Dual Parity and Striped.
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
161
Storage Profiles
Deleting a Storage Profile PCH Controller Definition
UCS-A /org/service-profile # scope org /
UCS-A /org # scope service-profile Service-Profile1
UCS-A /org/service-profile # create storage-profile-def
UCS-A /org/service-profile/storage-profile-def* # create controller-def Raid60Ctrlr
UCS-A /org/service-profile/storage-profile-def/controller-def* # create controller-mode-config
UCS-A /org/service-profile/storage-profile-def/controller-def/controller-mode-config* # set protect-config no
UCS-A /org/service-profile/storage-profile-def/controller-def/controller-mode-config* # set raid-mode raid-60-striped-dual-parity-and-striped
UCS-A /org/service-profile/storage-profile-def/controller-def/controller-mode-config* # commit-buffer
Deleting a Storage Profile PCH Controller Definition
SUMMARY STEPS
1.
UCS-A# scope org org-name
2.
UCS-A /org # scope storage-profile storage-profile-name
3.
UCS-A /org/storage-profile # delete controller-def controller-definition-name
4.
UCS-A /org/storage-profile* # commit-buffer
DETAILED STEPS
Step 1
Command or Action
UCS-A# scope org org-name
Purpose
Enters the organization mode for the specified organization.
To enter the root organization mode, enter / as the org-name .
Note This task assumes the storage profile is at the org level. If the storage profile is at the service profile level, see the example below for the steps to scope to the storage profile definition under the service profile.
Step 2
Step 3
Step 4
UCS-A /org # scope storage-profile storage-profile-name Enters storage-profile configuration mode for the selected storage profile.
Deletes a PCH controller definition with the specified name.
UCS-A /org/storage-profile # delete controller-def controller-definition-name
UCS-A /org/storage-profile* # commit-buffer Commits the transaction to the system configuration.
Example
This example shows how to delete a PCH controller definition called "raid1-controller" from the org-level storage profile named "storage-profile-A".
UCS-A# scope org
UCS-A /org # scope storage-profile storage-profile-A
UCS-A /org/storage-profile # delete controller-def raid1-controller
162
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
Storage Profiles
Migrating an M.2 Module
UCS-A /org/storage-profile* # commit-buffer
Migrating an M.2 Module
Migrating an M.2 module in SWRAID
Perform this procedure to migrate an M.2 module in SWRAID mode to a destination server:
Before you begin
Only UEFI boot mode is supported with software RAID configuration in the controller definition. This condition is applicable even if the drives are not used as boot drive. Ensure that the source and destination server boot mode is set to UEFI and controller definition is configured as same SWRAID (R0/R1).
Step 1
Step 2
Step 3
Step 4
Step 5
Gracefully shut down the server.
Physically remove the M.2 module.
The boot mode in the source server for SWRAID M.2 controller configuration in the source server has to be UEFI.
Configure the boot policy of destination server with UEFI boot parameters under embedded disk.
Insert the disk in the M.2 module in the destination server.
Power on the server.
Re-acknowledge the server.
Migrating an M.2 Module in AHCI Mode
Perform this procedure to migrate an M.2 module in NORAID mode to a destination server:
Before you begin
• If the source server is in legacy boot mode, ensure that the destination server is also in legacy boot mode and controller definition is configured as NORAID .
• If the source server is in UEFI boot mode, ensure that the destination server is also in UEFI boot mode and controller definition is configured as NORAID .
Step 1
Step 2
Step 3
Step 4
Step 5
Gracefully shut down the server.
Physically remove the M.2 module.
Do one of the following:
• If the disk under M.2 controller had boot mode as UEFI on the source server, configure the boot policy of the destination server with UEFI boot parameters.
• If the disk under M.2 controller had boot mode as legacy on the source server, configure the boot policy of the destination server as legacy mode
Insert the M.2 module in the destination server.
Power on the server.
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
163
Storage Profiles
Migrating a SWRAID Disk
Step 6 Re-acknowledge the server.
Note If the disk is faulty, the server shows the disk status as
to replace the faulty disk.
Not Detected . Perform
Migrating a SWRAID Disk
Perform this procedure to migrate a M.2 disk in SWRAID mode to a destination server:
Before you begin
Only UEFI boot mode is supported with software RAID configuration in the controller definition. This condition is applicable even if the drives are not used as boot drive. Ensure that the source and destination server boot mode is set to UEFI and controller definition is configured as same SWRAID (R0/R1).
Step 1
Step 2
Step 3
Step 4
Step 5
Gracefully shut down the server.
Physically remove the M.2 module and extract the disk.
If the disk is used as SWRAID in the source server the boot mode has to be UEFI and configure boot policy of destination server with UEFI boot parameters under embedded disk.
Insert the disk in the M.2 module in the destination server.
Power on the server.
Re-acknowledge the server.
Note The Drive State of the disk should show as Online . If the disk is faulty, the sever fails to detect the disk or the
Drive State shows as BAD (or FAILED ) instead of Online . Perform
Replacing a Faulty M.2 Disk, on page
to replace the faulty disk.
Migrating a JBOD Disk in AHCI Mode
Perform this procedure to migrate a JBOD disk in NORAID mode to a destination server:
Before you begin
• If the source server is in legacy boot mode, ensure that the destination server is also in legacy boot mode and controller definition is configured as NORAID .
• If the source server is in UEFI boot mode, ensure that the destination server is also in UEFI boot mode and controller definition is configured as NORAID .
Step 1
Step 2
Step 3
Gracefully shut down the server.
Physically remove the module and extract the M.2 disk.
Do one of the following:
• If the disk under M.2 controller had boot mode as UEFI on the source server, configure the boot policy of the destination server with UEFI boot parameters.
164
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
Storage Profiles
Replacing a Faulty M.2 Disk
Step 4
Step 5
Step 6
• If the disk under M.2 controller had boot mode as legacy on the source server, configure the boot policy of the destination server as legacy mode
Insert the M.2 disk in the M.2 module on the destination server.
Power on the server.
Re-acknowledge the server.
Replacing a Faulty M.2 Disk
Perform this procedure to replace a faulty M.2 disk.
Before you begin
Ensure that the SWRAID controller definition is configured and the replacement disk formatted empty drive.
Step 1
Step 2
Step 3
Step 4
Step 5
Gracefully power down the server.
Physically remove the faulty M.2 drive. Use the Serial Number and Disk Slot to identity the faulty disk.
Insert the replacement M.2 drive.
Power on the server.
Wait for the disk to rebuild and then re-acknowledge the server.
Note SWRAID rebuild may take anywhere between 35 to 75 minutes depending on the disk size, disk speed, OS content, and other parameters.
AHCI is a NORAID configuration and hence rebuild is not applicable.
Note After replacing the faulty M.2 drive, the operability state and drive-state of the drive in other slot change to
Degraded and Rebuilding. To bring back the drive to normal state, decommission and recommission the blade.
Associating a Storage Profile with a Service Profile
A storage profile created under org can be referred by multiple service profiles, and a name reference in service profile is needed to associate the storage profile with a service profile.
Important Storage profiles can be defined under org and under service profile (dedicated). Hence, a service profile inherits local LUNs from both possible storage profiles. A service profile can have a maximum of two such local LUNs.
SUMMARY STEPS
1.
UCS-A# scope org org-name
2.
UCS-A /org # scope service-profile service-profile-name
3.
UCS-A /org/service-profile # set storage-profile-name storage-profile-name
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
165
Storage Profiles
Displaying Details of All Local LUNs Inherited By a Service Profile
4.
UCS-A /org/service-profile* # commit-buffer
DETAILED STEPS
Step 1
Step 2
Step 3
Command or Action
UCS-A# scope org org-name
Purpose
Enters the organization mode for the specified organization.
To enter the root organization mode, enter / as the org-name .
UCS-A /org # scope service-profile service-profile-name Enters the specified service profile mode.
UCS-A /org/service-profile # set storage-profile-name storage-profile-name
Associates the specified storage profile with the service profile.
Note To dissociate the service profile from a storage profile, use the set storage-profile-name command and specify "" as the storage profile name.
Step 4 UCS-A /org/service-profile* # commit-buffer Commits the transaction to the system configuration.
Example
This example shows how to associate a storage profile with a service profile.
UCS-A# scope org
UCS-A /org # scope service-profile sp1
UCS-A /org/service-profile # set storage-profile-name stp2
This example shows how to dissociate a service profile from a storage profile.
UCS-A# scope org
UCS-A /org # scope service-profile sp1
UCS-A /org/service-profile # set storage-profile-name ""
Displaying Details of All Local LUNs Inherited By a Service Profile
Storage profiles can be defined under org and as a dedicated storage profile under service profile. Thus, a service profile inherits local LUNs from both possible storage profiles. It can have a maximum of 2 such local
LUNs. You can display the details of all local LUNs inherited by a service profile by using the following command:
SUMMARY STEPS
1.
UCS-A /org/service-profile # show local-lun-ref
166
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
Storage Profiles
Displaying Details of All Local LUNs Inherited By a Service Profile
DETAILED STEPS
Step 1
Command or Action
UCS-A /org/service-profile # show local-lun-ref
Purpose
Displays the following detailed information about all the local LUNs inherited by the specified service profile:
• Name —LUN name in the storage profile.
• Admin State —Specifies whether a local LUN should be deployed or not. Admin state can be Online or
Undeployed .
When the local LUN is being referenced by a service profile, if the auto-deploy status is no-auto-deploy then the admin state will be Undeployed , else it will be Online . After the local LUN is referenced by a service profile, any change made to this local LUN's auto-deploy status is not reflected in the admin state of the LUN inherited by the service profile.
• RAID Level —Summary of the RAID level of the disk group used.
• Provisioned Size (GB) —Size, in GB, of the LUN specified in the storage profile.
• Assigned Size (MB) —Size, in MB, assigned by
UCSM.
• Config State —State of LUN configuration. The states can be one of the following:
• Applying —Admin state is online, the LUN is associated with a server, and the virtual drive is being created.
• Applied —Admin state is online, the LUN is associated with a server, and the virtual drive is created.
• Apply Failed —Admin stage is online, the LUN is associated with a server, but the virtual drive creation failed.
• Not Applied —The LUN is not associated with a server, or the LUN is associated with a service profile, but admin state is undeployed.
• Not In Use —Service profile is using the virtual drive, but the virtual drive is not associated with a server.
• Reference LUN —The preprovisioned virtual drive name, or UCSM-generated virtual drive name.
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
167
Storage Profiles
Displaying Details of All Local LUNs Inherited By a Service Profile
Command or Action Purpose
• Deploy Name —The virtual drive name after deployment.
• ID —Virtual drive ID.
• Drive State —State of the virtual drive. The states are:
• Unknown
• Optimal
• Degraded
• Inoperable
• Partially Degraded
Example
UCS-A /org/service-profile # show local-lun-ref
Local LUN Ref:
Profile LUN Name Admin State RAID Level
Size (MB) Config State Referenced Lun Deploy Name ID
Provisioned Size (GB) Assigned
Drive State
---------------- ----------- ---------------------- ----------------------
-------------------- ------------ -------------- ----------- ----------- ----------luna
1024 Applied lunb
1024 Applied
Online luna-1
Online lunb-1
UCS-A /org/service-profile #
RAID 0 Striped luna-1
RAID 0 Striped lunb-1
1003
1004
1
1
Optimal
Optimal
Local LUN Ref:
Name Admin State RAID Level Provisioned Size (GB) Assigned
Size (MB) Config State Referenced Lun Deploy Name ID Drive State
---------------- ----------- ---------------------- ----------------------
-------------------- ------------ -------------- ----------- ----------- ----------lun111 Online RAID 0 Striped 30 30720
Applied lun111-1 lun111-1 1001 Optimal lun201
Not Applied
Online Unspecified 1 0
168
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
Storage Profiles
Importing Foreign Configurations for a RAID Controller
Importing Foreign Configurations for a RAID Controller
SUMMARY STEPS
1.
UCS-A# scope chassis chassis-num
2.
UCS-A /chassis # scope raid-controller raid-contr-id { sas | sata }
3.
UCS-A /chassis/raid-controller # set admin-state import-foreign-configuration
DETAILED STEPS
Step 1
Step 2
Step 3
Command or Action
UCS-A# scope chassis chassis-num
Purpose
Enters chassis mode for the specified chassis.
UCS-A /chassis # scope raid-controller raid-contr-id { sas
| sata }
Enters RAID controller chassis mode.
UCS-A /chassis/raid-controller # set admin-state import-foreign-configuration
Allows import of configurations from local disks that are in the Foreign Configuration state.
Example
This example shows how to import foreign configurations from local disks that are in the Foreign
Configuration state:
UCS-A# scope chassis 1
UCS-A /chassis # scope raid-controller 1 sas
UCS-A /chassis/raid-controller # set admin-state import-foreign-configuration
UCS-A /chassis/raid-controller* #
Configuring Local Disk Operations
SUMMARY STEPS
1.
UCS-A# scope chassis chassis-num
2.
UCS-A /chassis # scope raid-controller raid-contr-id { sas | sata }
3.
UCS-A /chassis/raid-controller # scope local-disk local-disk-id
4.
UCS-A /chassis/raid-controller/local-disk # set admin-state { clear-foreign-configuration | dedicated-hot-spare [ admin-vd-id ] | prepare-for-removal | remove-hot-spare | unconfigured-good | undo-prepare-for-removal }
DETAILED STEPS
Step 1
Step 2
Command or Action
UCS-A# scope chassis chassis-num
Purpose
Enters chassis mode for the specified chassis.
UCS-A /chassis # scope raid-controller raid-contr-id { sas
| sata }
Enters RAID controller chassis mode.
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
169
Storage Profiles
Configuring Local Disk Operations
Step 3
Step 4
Command or Action
UCS-A /chassis/raid-controller # scope local-disk local-disk-id
Purpose
Enters local disk configuration mode.
UCS-A /chassis/raid-controller/local-disk # set admin-state
{ clear-foreign-configuration | dedicated-hot-spare
[ admin-vd-id ] | prepare-for-removal | remove-hot-spare
| unconfigured-good | undo-prepare-for-removal }
Configures the local disk to one of the following states:
• clear-foreign-configuration —Clears any foreign configuration that exists in a local disk when it is introduced into a new configuration.
• dedicated-hot-spare —Specifies the local disk as a dedicated hot spare. The admin virtual drive ID that you can assign ranges from 0 to 4294967295.
• prepare-for-removal —Specifies that the local disk is marked for removal from the chassis.
• remove-hot-spare —Specifies that the local disk is no longer a hot spare. Use this only to clear any mismatch faults.
• unconfigured-good —Specifies that the local disk can be configured.
• undo-prepare-for-removal —Specifies that the local disk is no longer marked for removal from the chassis.
Example
This example shows how to clear any foreign configuration from a local disk:
UCS-A /chassis/raid-controller/local-disk # set admin-state clear-foreign-configuration
This example shows how to specify a local disk as a dedicated hot spare:
UCS-A /chassis/raid-controller/local-disk* # set admin-state dedicated-hot-spare 1001
This example shows how to specify that a local disk is marked for removal from the chassis:
UCS-A /chassis/raid-controller/local-disk* # set admin-state prepare-for-removal
This example shows how to specify that a local disk is marked for removal as a hot spare:
UCS-A /chassis/raid-controller/local-disk* # set admin-state remove-hot-spare
This example shows how to specify that a local disk is working, but is unconfigured for use:
UCS-A /chassis/raid-controller/local-disk* # set admin-state unconfigured-good
This example shows how to specify that a local disk is no longer marked for removal from the chassis:
UCS-A /chassis/raid-controller/local-disk* # set admin-state undo-prepare-for-removal
170
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
Storage Profiles
Configuring Virtual Drive Properties
Configuring Virtual Drive Properties
All virtual drives in a disk group must be managed by using a single disk group policy.
If you try to associate to a server that does not support these properties, a configuration error will be generated.
Only the following storage controllers support these properties:
• LSI 6G MegaRAID SAS 9266-8i
• LSI 6G MegaRAID SAS 9271-8i
• LSI 6G MegaRAID 9265-8i
• LSI MegaRAID SAS 2208 ROMB
• LSI MegaRAID SAS 9361-8i
For the LSI MegaRAID SAS 2208 ROMB controller, these properties are supported only in the B420-M3 blade server. For the other controllers, these properties are supported in multiple rack servers.
Note If you have a setup with the Cisco Boot Optimized M.2 Raid Controller (UCS-M2-HWRAID), then:
• You can create only one virtual drive
• For strip-size , select 64KB or 32KB . Selecting any other value results in configuration error.
• For access-policy , read-policy , write-cache-policy , io-policy , and drive-cache , select platform-default .
Selecting any other value results in configuration error.
SUMMARY STEPS
1.
UCS-A# scope org org-name
2.
UCS-A /org# scope disk-group-config-policy disk-group-name
3.
UCS-A /org/disk-group-config-policy* # create virtual-drive-def
4.
UCS-A /org/disk-group-config-policy/virtual-drive-def* # set access-policy policy-type
5.
UCS-A /org/disk-group-config-policy/virtual-drive-def* # set drive-cache state
6.
UCS-A /org/disk-group-config-policy/virtual-drive-def* # set io-policy policy-type
7.
UCS-A /org/disk-group-config-policy/virtual-drive-def* # set read-policy policy-type
8.
UCS-A /org/disk-group-config-policy/virtual-drive-def* # set strip-size strip-size
9.
UCS-A /org/disk-group-config-policy/virtual-drive-def* # set write-cache-policy policy-type
10.
UCS-A /org/disk-group-config-policy/virtual-drive-def* # commit-buffer
11.
UCS-A /org/disk-group-config-policy/virtual-drive-def* # show
DETAILED STEPS
Step 1
Command or Action
UCS-A# scope org org-name
Purpose
Enters the organization mode for the specified organization.
To enter the root organization mode, enter / as the org-name .
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
171
Storage Profiles
Configuring Virtual Drive Properties
Step 2
Step 3
Step 4
Step 5
Step 6
Step 7
Step 8
Command or Action
UCS-A /org# scope disk-group-config-policy disk-group-name
UCS-A /org/disk-group-config-policy* # virtual-drive-def create
Purpose
Enters disk group configuration policy mode for the specified disk group name.
Creates a virtual drive definition and enters the virtual drive definition mode.
UCS-A /org/disk-group-config-policy/virtual-drive-def*
# set access-policy policy-type
Specifies the access policy. This can be one of the following:
• blocked
• platform-default
• read-only:
• read-write
UCS-A /org/disk-group-config-policy/virtual-drive-def*
# set drive-cache state
Specifies the state of the drive cache. This can be one of the following:
• enable
• disable
• no-change
• platform-default
Important In Cisco UCS Release 2.5, the drive cache state cannot be changed. It will remain as platform-default , irrespective of the drive cache state that you select.
UCS-A /org/disk-group-config-policy/virtual-drive-def*
# set io-policy policy-type
Specifies the I/O policy. This can be one of the following:
• cached
• direct
• platform-default
UCS-A /org/disk-group-config-policy/virtual-drive-def*
# set read-policy policy-type
Specifies the read policy. This can be one of the following:
• normal
• platform-default
• read-ahead
UCS-A /org/disk-group-config-policy/virtual-drive-def*
# set strip-size strip-size
Specifies the strip size. This can be one of the following:
• 64 KB
• 128 KB
• 256 KB
172
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
Storage Profiles
Configuring Virtual Drive Properties
Step 9
Step 10
Step 11
Command or Action Purpose
• 512 KB
• 1024 KB
• platform-default
UCS-A /org/disk-group-config-policy/virtual-drive-def*
# set write-cache-policy policy-type
Specifies the write-cache-policy. This can be one of the following:
• always-write-back
• platform-default
• write-back-good-bbu
• write-through
UCS-A /org/disk-group-config-policy/virtual-drive-def*
# commit-buffer
UCS-A /org/disk-group-config-policy/virtual-drive-def*
# show
Commits the transaction to the system configuration.
Displays the configured virtual drive properties.
Example
This example shows how to configure virtual disk properties:
UCS-A# scope org
UCS-A /org # scope disk-group-config-policy raid0policy
UCS-A /org/disk-group-config-policy # create virtual-drive-def
UCS-A /org/disk-group-config-policy/virtual-drive-def* # set access-policy read-write
UCS-A /org/disk-group-config-policy/virtual-drive-def* # set drive-cache enable
UCS-A /org/disk-group-config-policy/virtual-drive-def* # set io-policy cached
UCS-A /org/disk-group-config-policy/virtual-drive-def* # set read-policy normal
UCS-A /org/disk-group-config-policy/virtual-drive-def* # set strip-size 1024
UCS-A /org/disk-group-config-policy/virtual-drive-def* # set write-cache-policy write-through
UCS-A /org/disk-group-config-policy/virtual-drive-def* # commit-buffer
UCS-A /org/disk-group-config-policy/virtual-drive-def # show
Virtual Drive Def:
Strip Size (KB): 1024KB
Access Policy: Read Write
Read Policy: Normal
Configured Write Cache Policy: Write Through
IO Policy: Cached
Drive Cache: Enable
UCS-A /org/disk-group-config-policy/virtual-drive-def #
What to do next
Create a Storage Profile
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
173
Storage Profiles
Deleting an Orphaned Virtual Drive
Deleting an Orphaned Virtual Drive
SUMMARY STEPS
1.
UCS-A# scope chassis chassis-num
2.
UCS-A /chassis # scope raid-controller raid-contr-id { sas | sata }
3.
(Optional) UCS-A /chassis/raid-controller # delete virtual-drive id virtual-drive-id
4.
(Optional) UCS-A /chassis/raid-controller # delete virtual-drive name virtual-drive-name
5.
(Optional) UCS-A /chassis/raid-controller # scope virtual-drive virtual-drive-id
6.
UCS-A /chassis/raid-controller/virtual-drive # set admin-state delete
7.
UCS-A /chassis/raid-controller/virtual-drive # commit-buffer
DETAILED STEPS
Step 1
Step 2
Command or Action
UCS-A# scope chassis chassis-num
Step 3
Purpose
Enters chassis mode for the specified chassis.
UCS-A /chassis # scope raid-controller raid-contr-id { sas
| sata }
Enters RAID controller chassis mode.
(Optional) UCS-A /chassis/raid-controller # delete
virtual-drive id virtual-drive-id
Deletes the orphaned virtual drive with the specified virtual drive ID.
Step 4
Step 5
Step 6
Step 7
(Optional) UCS-A /chassis/raid-controller #
virtual-drive name virtual-drive-name
(Optional) UCS-A /chassis/raid-controller #
virtual-drive virtual-drive-id delete scope
UCS-A /chassis/raid-controller/virtual-drive # set admin-state delete
UCS-A /chassis/raid-controller/virtual-drive # commit-buffer
Deletes the orphaned virtual drive with the specified virtual drive name.
Enters virtual drive mode for the specified orphaned virtual drive.
Deletes the orphaned virtual drive.
Commits the transaction to the system configuration.
Example
This example shows how to delete an orphan virtual drive by specifying the virtual drive ID.
UCS-A# scope chassis 1
UCS-A /chassis # scope raid-controller 1 sas
UCS-A /chassis/raid-controller # show virtual-drive
Virtual Drive:
ID: 1001
Name: lun111-1
Block Size: 512
Blocks: 62914560
Size (MB): 30720
Operability: Operable
Presence: Equipped
Oper Device ID: 0
Change Qualifier: No Change
Config State: Applied
174
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
Storage Profiles
Deleting an Orphaned Virtual Drive
Deploy Action: No Action
ID: 1002
Name: luna-1
Block Size: 512
Blocks: 2097152
Size (MB): 1024
Operability: Operable
Presence: Equipped
Oper Device ID: 1
Change Qualifier: No Change
Config State: Orphaned
Deploy Action: No Action
ID: 1003
Name: lunb-1
Block Size: 512
Blocks: 2097152
Size (MB): 1024
Operability: Operable
Presence: Equipped
Oper Device ID: 2
Change Qualifier: No Change
Config State: Orphaned
Deploy Action: No Action
ID: 1004
Name: lunb-2
Block Size: 512
Blocks: 2097152
Size (MB): 1024
Operability: Operable
Presence: Equipped
Oper Device ID: 3
Change Qualifier: No Change
Config State: Orphaned
Deploy Action: No Action
ID: 1005
Name: luna-2
Block Size: 512
Blocks: 2097152
Size (MB): 1024
Operability: Operable
Presence: Equipped
Oper Device ID: 4
Change Qualifier: No Change
Config State: Orphaned
Deploy Action: No Action
...
UCS-A /chassis/raid-controller # delete virtual-drive id 1002
Warning: When committed, the virtual drive will be deleted, which may result in data loss.
UCS-A /chassis/raid-controller # commit-buffer
This example shows how to delete an orphan virtual drive by specifying the virtual drive name.
UCS-A# scope chassis 1
UCS-A /chassis # scope raid-controller 1 sas
UCS-A /chassis/raid-controller # show virtual-drive
Virtual Drive:
ID: 1001
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
175
Storage Profiles
Deleting an Orphaned Virtual Drive
Name: lun111-1
Block Size: 512
Blocks: 62914560
Size (MB): 30720
Operability: Operable
Presence: Equipped
Oper Device ID: 0
Change Qualifier: No Change
Config State: Applied
Deploy Action: No Action
ID: 1003
Name: lunb-1
Block Size: 512
Blocks: 2097152
Size (MB): 1024
Operability: Operable
Presence: Equipped
Oper Device ID: 2
Change Qualifier: No Change
Config State: Orphaned
Deploy Action: No Action
ID: 1004
Name: lunb-2
Block Size: 512
Blocks: 2097152
Size (MB): 1024
Operability: Operable
Presence: Equipped
Oper Device ID: 3
Change Qualifier: No Change
Config State: Orphaned
Deploy Action: No Action
ID: 1005
Name: luna-2
Block Size: 512
Blocks: 2097152
Size (MB): 1024
Operability: Operable
Presence: Equipped
Oper Device ID: 4
Change Qualifier: No Change
Config State: Orphaned
Deploy Action: No Action
...
UCS-A /chassis/raid-controller # delete virtual-drive name lunb-1
Warning: When committed, the virtual drive will be deleted, which may result in data loss.
UCS-A /chassis/raid-controller # commit-buffer
This example shows how to delete an orphan virtual drive by setting the admin-state.
UCS-A# scope chassis 1
UCS-A /chassis # scope raid-controller 1 sas
UCS-A /chassis/raid-controller # scope virtual-drive 1004
UCS-A /chassis/raid-controller/virtual-drive # set admin-state delete
Warning: When committed, the virtual drive will be deleted, which may result in data loss.
UCS-A /chassis/raid-controller/virtual-drive # commit-buffer
176
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
Storage Profiles
Renaming an Orphaned Virtual Drive
Renaming an Orphaned Virtual Drive
SUMMARY STEPS
1.
UCS-A# scope chassis chassis-num
2.
UCS-A /chassis # scope raid-controller raid-contr-id { sas | sata }
3.
UCS-A /chassis/raid-controller # scope virtual-drive virtual-drive-id
4.
UCS-A /chassis/raid-controller/virtual-drive # set name virtual-drive-name
5.
UCS-A /chassis/raid-controller/virtual-drive # commit-buffer
DETAILED STEPS
Step 1
Step 2
Command or Action
UCS-A# scope chassis chassis-num
Step 3
Step 4
Step 5
Purpose
Enters chassis mode for the specified chassis.
UCS-A /chassis # scope raid-controller raid-contr-id { sas
| sata }
Enters RAID controller chassis mode.
Enters virtual drive mode for the specified virtual drive.
UCS-A /chassis/raid-controller # scope virtual-drive virtual-drive-id
UCS-A /chassis/raid-controller/virtual-drive # set name virtual-drive-name
UCS-A /chassis/raid-controller/virtual-drive # commit-buffer
Specifies a name for the orphan virtual drive.
Commits the transaction to the system configuration.
Example
This example shows how to specify a name for an orphan virtual drive.
UCS-A /chassis # scope raid-controller 1 sas
UCS-A /chassis/raid-controller # scope virtual-drive 1060
UCS-A /chassis/raid-controller/virtual-drive* # set name vd1
UCS-A /chassis/raid-controller/virtual-drive* # commit-buffer
Boot Policy for Local Storage
You can specify the primary boot device for a storage controller as a local LUN or a JBOD disk. Each storage controller can have one primary boot device. However, in a storage profile, you can set only one device as the primary boot LUN.
Beginning with 4.0(4a), Cisco UCS Manager supports Cisco boot optimized M.2 Raid controller based off
Marvell 88SE92xx PCIe to SATA 6Gb/s controller (UCS-M2-HWRAID). The controller supports only UEFI boot mode.
Local storage option in the boot policy supports the boot from the SATA drives in the Cisco boot optimized
M.2 Raid controller.
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
177
Storage Profiles
Configuring the Boot Policy for a Local LUN
Also, embedded local storage option in the boot policy supports the boot from the SATA drives in the Cisco boot optimized M.2 Raid controller. The primary and the secondary type boot specifically from the M.2 SATA drives.
Note Cisco UCS S3260 M3 server nodes do not support Any as an option for the Local LUN Image Path while adding a local LUN to the boot policy through the Cisco UCS Manager GUI. In the Cisco UCS Manager CLI,
Cisco UCS S3260 M3 server nodes do not support the local-any command option.
Configuring the Boot Policy for a Local LUN
Note In Cisco UCS Manager Release 2.5, you cannot configure JBOD as a boot device.
SUMMARY STEPS
1.
UCS-A# scope org org-name
2.
UCS-A /org # scope boot-policy policy-name
3.
UCS-A /org/boot-policy # create storage
4.
UCS-A /org/boot-policy/storage # create local
5.
UCS-A /org/boot-policy/storage/local/ # create local-lun
6.
UCS-A /org/boot-policy/storage/local/local-lun # create local-lun-image-path { primary | secondary }
7.
UCS-A /org/boot-policy/storage/local/local-lun/local-lun-image-path # set lunname lun_name
8.
UCS-A /org/boot-policy/storage/local/ local-storage-device # commit-buffer
DETAILED STEPS
Step 1
Step 2
Step 3
Step 4
Step 5
Step 6
Command or Action
UCS-A# scope org org-name
UCS-A /org # scope boot-policy policy-name
UCS-A /org/boot-policy # create storage
Purpose
Enters organization mode for the specified organization.
To enter the root organization mode, type / as the org-name .
Enters organization boot policy mode for the specified boot policy.
Creates a storage boot for the boot policy and enters organization boot policy storage mode.
UCS-A /org/boot-policy/storage # create local Creates a local storage location and enters the boot policy local storage mode.
UCS-A /org/boot-policy/storage/local/ # create local-lun Specifies a local hard disk drive as the local storage.
UCS-A /org/boot-policy/storage/local/local-lun # create local-lun-image-path { primary | secondary }
Specifies the boot order for the LUN that you specify.
Important Cisco UCS Manager Release 2.2(4) does not support secondary boot order.
178
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
Storage Profiles
Configuring the Boot Policy for a Local JBOD Disk
Step 7
Step 8
Command or Action Purpose
UCS-A
/org/boot-policy/storage/local/local-lun/local-lun-image-path
# set lunname lun_name
Specifies the name of the LUN that you want to boot from.
UCS-A /org/boot-policy/storage/local/ local-storage-device
# commit-buffer
Commits the transaction to the system configuration.
Example
The following example shows how to create a boot policy named lab1-boot-policy, create a local hard disk drive boot for the policy, specify a boot order and a LUN to boot from, and commit the transaction:
UCS-A# scope org /
UCS-A /org* # scope boot-policy lab1-boot-policy
UCS-A /org/boot-policy* # create storage
UCS-A /org/boot-policy/storage* # create local
UCS-A /org/boot-policy/storage/local* # create local-lun
UCS-A /org/boot-policy/storage/local/local-lun # create local-lun-image-path primary
UCS-A /org/boot-policy/storage/local/local-lun/local-lun-image-path # set lunname luna
UCS-A /org/boot-policy/storage/local/local-lun/local-lun-image-path # commit-buffer
UCS-A /org/boot-policy/storage/local/local-lun/local-lun-image-path #
What to do next
Include the boot policy in a service profile and template.
Configuring the Boot Policy for a Local JBOD Disk
SUMMARY STEPS
1.
UCS-A# scope org org-name
2.
UCS-A /org # scope boot-policy policy-name
3.
UCS-A /org/boot-policy # create storage
4.
UCS-A /org/boot-policy/storage # create local
5.
UCS-A /org/boot-policy/storage/local/ # create local-jbod
6.
UCS-A /org/boot-policy/storage/local/local-jbod # create local-lun-image-path{primary | secondary}
7.
UCS-A /org/boot-policy/storage/local/local-jbod/local-disk-image-path # set slotnumber slotnumber
8.
UCS-A /org/boot-policy/storage/local/local-jbod/local-disk-image-path* # commit-buffer
DETAILED STEPS
Step 1
Command or Action
UCS-A# scope org org-name
Purpose
Enters organization mode for the specified organization.
To enter the root organization mode, type / as the org-name .
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
179
Storage Profiles
Configuring the Boot Policy for an Embedded Local LUN
Step 2
Step 3
Step 4
Step 5
Step 6
Step 7
Step 8
Command or Action
UCS-A /org # scope boot-policy policy-name
UCS-A /org/boot-policy # create storage
UCS-A /org/boot-policy/storage # create local
Purpose
Enters organization boot policy mode for the specified boot policy.
Creates a storage boot for the boot policy and enters organization boot policy storage mode.
Creates a local storage location and enters the boot policy local storage mode.
UCS-A /org/boot-policy/storage/local/ # create local-jbod Specifies the local JBOD as the local storage.
UCS-A /org/boot-policy/storage/local/local-jbod # create
local-lun-image-path{primary | secondary}
UCS-A
/org/boot-policy/storage/local/local-jbod/local-disk-image-path
# set slotnumber slotnumber
UCS-A
/org/boot-policy/storage/local/local-jbod/local-disk-image-path*
# commit-buffer
Commits the transaction to the system configuration.
Example
The following example shows how to create a boot policy named lab1-boot-policy, create an local
JBOD disk drive boot for the policy, specify a boot order and a JBOD to boot from, and commit the transaction:
UCS-A# scope org /
UCS-A /org* # scope boot-policy lab1-boot-policy
UCS-A /org/boot-policy* # create storage
UCS-A /org/boot-policy/storage* # create local
UCS-A /org/boot-policy/storage/local/ # create local-jbod
UCS-A /org/boot-policy/storage/local/local-jbod* # create local-disk-image-path primary
UCS-A /org/boot-policy/storage/local/local-jbod/local-disk-image-path # set slotnumber 1
UCS-A /org/boot-policy/storage/local/local-jbod/local-disk-image-path* # commit-buffer
UCS-A /org/boot-policy/storage/local/local-jbod/local-disk-image-path #
What to do next
Include the boot policy in a service profile and template.
Configuring the Boot Policy for an Embedded Local LUN
Note Specify one bootable LUN as either primary or secondary boot device. If you specify the bootable LUN as both primary and secondary boot devices, the boot policy will result in the service profile configuration error.
SUMMARY STEPS
1.
UCS-A# scope org org-name
180
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
Storage Profiles
Configuring the Boot Policy for an Embedded Local Disk
2.
UCS-A /org # scope boot-policy policy-name
3.
UCS-A /org/boot-policy # create storage
4.
UCS-A /org/boot-policy/storage # create local
5.
UCS-A /org/boot-policy/storage/local/ # create embedded-local-lun
6.
UCS-A /org/boot-policy/storage/local/embedded-local-lun* # commit-buffer
DETAILED STEPS
Step 1
Step 2
Step 3
Step 4
Step 5
Step 6
Command or Action
UCS-A# scope org org-name
UCS-A /org # scope boot-policy policy-name
UCS-A /org/boot-policy # create storage
UCS-A /org/boot-policy/storage # create local
Purpose
Enters organization mode for the specified organization.
To enter the root organization mode, type / as the org-name .
Enters organization boot policy mode for the specified boot policy.
Creates a storage boot for the boot policy and enters organization boot policy storage mode.
Creates a local storage location and enters the boot policy local storage mode.
UCS-A /org/boot-policy/storage/local/ # create embedded-local-lun
Specifies the embedded local LUN as the local storage.
UCS-A /org/boot-policy/storage/local/embedded-local-lun*
# commit-buffer
Commits the transaction to the system configuration.
Example
The following example shows how to create a boot policy named lab1-boot-policy, create an embedded
LUN boot for the policy, specify a boot order and a LUN to boot from, and commit the transaction:
UCS-A# scope org /
UCS-A /org* # scope boot-policy lab1-boot-policy
UCS-A /org/boot-policy* # create storage
UCS-A /org/boot-policy/storage* # create local
UCS-A /org/boot-policy/storage/local/ # create embedded-local-lun
UCS-A /org/boot-policy/storage/local/embedded-local-lun* # commit-buffer
UCS-A /org/boot-policy/storage/local/embedded-local-lun #
What to do next
Include the boot policy in a service profile and template.
Configuring the Boot Policy for an Embedded Local Disk
Note For Cisco UCS C125 M5 Server, if there is no separate PCIe storage controller, then do not configure boot policy for embedded local disk. Instead, use Add Local Disk option.
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
181
Storage Profiles
Configuring the Boot Policy for an Embedded Local Disk
SUMMARY STEPS
1.
UCS-A# scope org org-name
2.
UCS-A /org # scope boot-policy policy-name
3.
UCS-A /org/boot-policy # create storage
4.
UCS-A /org/boot-policy/storage # create local
5.
UCS-A /org/boot-policy/storage/local/ # create embedded-local-jbod
6.
UCS-A /org/boot-policy/storage/local/embedded-local-jbod* # commit-buffer
DETAILED STEPS
Step 1
Step 2
Step 3
Step 4
Step 5
Step 6
Command or Action
UCS-A# scope org org-name
UCS-A /org # scope boot-policy policy-name
UCS-A /org/boot-policy # create storage
Purpose
Enters organization mode for the specified organization.
To enter the root organization mode, type / as the org-name .
Enters organization boot policy mode for the specified boot policy.
Creates a storage boot for the boot policy and enters organization boot policy storage mode.
UCS-A /org/boot-policy/storage # create local Creates a local storage location and enters the boot policy local storage mode.
UCS-A /org/boot-policy/storage/local/ # create embedded-local-jbod
Specifies the embedded local JBOD as the local storage.
UCS-A /org/boot-policy/storage/local/embedded-local-jbod*
# commit-buffer
Commits the transaction to the system configuration.
Example
The following example shows how to create a boot policy named lab1-boot-policy, create an embedded
JBOD disk drive boot for the policy, specify a boot order and a JBOD to boot from, and commit the transaction:
UCS-A# scope org /
UCS-A /org* # scope boot-policy lab1-boot-policy
UCS-A /org/boot-policy* # create storage
UCS-A /org/boot-policy/storage* # create local
UCS-A /org/boot-policy/storage/local/ # create embedded-local-jbod
UCS-A /org/boot-policy/storage/local/embedded-local-jbod* # commit-buffer
UCS-A /org/boot-policy/storage/local/embedded-local-jbod #
What to do next
Include the boot policy in a service profile and template.
182
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
Storage Profiles
Local LUN Operations in a Service Profile
Local LUN Operations in a Service Profile
Although a service profile is derived from a service profile template, the following operations can be performed for each local LUN at the individual service profile level:
•
Preprovisioning a LUN Name or Claiming an Orphan LUN, on page 183
•
Deploying and Undeploying a LUN, on page 184
•
Renaming a Service Profile Referenced LUN, on page 185
Note Preprovisioning a LUN name, claiming an orphan LUN, and deploying or undeploying a LUN result in server reboot.
Preprovisioning a LUN Name or Claiming an Orphan LUN
You can preprovision a LUN name or claim an orphan LUN by using the set ref-name command.
Preprovisioning a LUN name or claiming an orphan LUN can be done only when the admin state of the LUN is Undeployed . You can also manually change the admin state of the LUN to Undeployed and claim an orphan LUN.
Important This operation will reboot the server.
If the LUN name is empty, set a LUN name before claiming it.
SUMMARY STEPS
1.
UCS-A# scope org org-name
2.
UCS-A /org# scope service-profile service-profile-name
3.
UCS-A /org/service-profile# enter local-lun-ref lun-name
4.
UCS-A /org/service-profile/local-lun-ref# set ref-name ref-lun-name
DETAILED STEPS
Step 1
Step 2
Step 3
Command or Action
UCS-A# scope org org-name
Purpose
Enters the organization mode for the specified organization.
To enter the root organization mode, enter / as the org-name .
UCS-A /org# scope service-profile service-profile-name Enters the specified service profile mode.
Step 4
UCS-A /org/service-profile# enter local-lun-ref lun-name Enters the specified LUN.
UCS-A /org/service-profile/local-lun-ref# set ref-name ref-lun-name
Sets the referenced LUN name.
If this LUN name exists and the LUN is orphaned, its is claimed by the service profile. If this LUN does not exist, a new LUN is created with the specified name.
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
183
Storage Profiles
Deploying and Undeploying a LUN
• If the LUN exists and is not orphaned, a configuration failure occurs.
• If a LUN is already referred to and the ref-name is changed, it will release the old LUN and will claim or create a LUN with the ref-name. The old LUN is marked as an orphan after the LUN reference is removed from the server.
Example
This examples shows how to preprovision a LUN name.
UCS-A# scope org
UCS-A /org # scope service-profile sp1
UCS-A /org/service-profile* # enter local-lun-ref lun1
UCS-A /org/service-profile/local-lun-ref* # set ref-name lun2
Deploying and Undeploying a LUN
You can deploy or undeploy a LUN by using the admin-state command. If the admin state of a local LUN is Undeployed , the reference of that LUN is removed and the LUN is not deployed.
Important This operation will reboot the server.
SUMMARY STEPS
1.
UCS-A# scope org org-name
2.
UCS-A /org# scope service-profile service-profile-name
3.
UCS-A /org/service-profile# enter local-lun-ref lun-name
4.
UCS-A /org/service-profile/local-lun-ref# set admin-state { online | undeployed }
DETAILED STEPS
Step 1
Step 2
Step 3
Step 4
Command or Action
UCS-A# scope org org-name
Purpose
Enters the organization mode for the specified organization.
To enter the root organization mode, enter / as the org-name .
UCS-A /org# scope service-profile service-profile-name Enters the specified service profile mode.
UCS-A /org/service-profile# enter local-lun-ref lun-name Enters the specified LUN.
UCS-A /org/service-profile/local-lun-ref# set admin-state
{ online | undeployed }
Sets the admin state of the specified LUN to online or undeployed .
If a LUN is already referred to and the admin state is set to undeployed , it will release the old LUN. The old LUN is marked as orphan after the LUN reference is removed from the server.
184
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
Storage Profiles
Renaming a Service Profile Referenced LUN
Example
This examples shows how to deploy a LUN.
UCS-A# scope org
UCS-A /org # scope service-profile sp1
UCS-A /org/service-profile* # enter local-lun-ref lun1
UCS-A /org/service-profile/local-lun-ref* # set admin-state online
This examples shows how to undeploy a LUN.
UCS-A# scope org
UCS-A /org # scope service-profile sp1
UCS-A /org/service-profile* # enter local-lun-ref lun1
UCS-A /org/service-profile/local-lun-ref* # set admin-state undeployed
Renaming a Service Profile Referenced LUN
SUMMARY STEPS
1.
UCS-A# scope org org-name
2.
UCS-A /org# scope service-profile service-profile-name
3.
UCS-A /org/service-profile# enter local-lun-ref lun-name
4.
UCS-A /org/service-profile/local-lun-ref# set name
DETAILED STEPS
Step 1
Step 2
Step 3
Step 4
Command or Action
UCS-A# scope org org-name
Purpose
Enters the organization mode for the specified organization.
To enter the root organization mode, enter / as the org-name .
UCS-A /org# scope service-profile service-profile-name Enters the specified service profile mode.
UCS-A /org/service-profile# enter local-lun-ref lun-name Enters the specified LUN.
UCS-A /org/service-profile/local-lun-ref# set name Renames the referenced LUN.
Example
This examples shows how to rename a LUN referenced by a service profile.
UCS-A# scope org
UCS-A /org # scope service-profile sp1
UCS-A /org/service-profile* # enter local-lun-ref lun1
UCS-A /org/service-profile/local-lun-ref* # set name lun11
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
185
Renaming a Service Profile Referenced LUN
Storage Profiles
186
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
C H A P T E R
11
Configuring SD Card Support
This chapter includes the following sections:
•
FlexFlash Secure Digital Card Support, on page 187
•
FlexUtil Secure Digital Card Support, on page 189
FlexFlash Secure Digital Card Support
Overview
Cisco UCS B-Series, C-Series M4 and higher, and S-Series M4 servers support internal Secure Digital (SD) memory cards. The SD cards are hosted by the Cisco Flexible Flash storage controller, a PCI-based controller which has two slots for SD cards. The cards contain a single partition called HV. When FlexFlash is enabled,
Cisco UCS Manager displays the HV partition as a USB drive to both the BIOS and the host operating system.
You can populate one or both the SD card slots that are provided. If two SD cards are populated, you can use them in a mirrored mode.
Note Do not mix different capacity cards in the same server.
The SD cards can be used to store operating system boot images or other information. The following figure illustrates the SD card slots.
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
187
Configuring SD Card Support
FlexFlash Secure Digital Card Support
Figure 3: SD Card Slots
FlexFlash is disabled by default. You can enable FlexFlash in a local disk policy used in a service profile.
When FlexFlash is enabled in a local disk policy, and the server is capable of supporting SD cards, the FlexFlash controller is enabled during service profile association. If a server is not capable of supporting SD cards or has an older CIMC version, a config failure message is displayed.
If you disable FlexFlash in a supported server, the Hypervisor or HV partition is immediately disconnected from the host. The FlexFlash controller will also be disabled as part of a related service profile disassociation.
The FlexFlash controller supports RAID-1 for dual SD cards. The FlexFlash scrub policy erases the HV partition in both cards, and brings the cards to a healthy RAID state.
You can configure new SD cards in a RAID pair and format them using one of the following methods:
• Format the SD cards.
• For an associated server, create a FlexFlash scrub policy and disassociate the service profile from the server. For an unassociated server, create a FlexFlash scrub policy and reacknowledge the server after modifying the default scrub policy.
The Scrub Policy Settings section in the Cisco UCS Manager Server Management Guide provides more details about the usage of the scrub policy.
Note Disable the scrub policy as soon as the pairing is complete.
To boot from the HV partition, the SD card must be present in the boot policy used in the service profile.
FlexFlash Firmware Management
The FlexFlash controller firmware is bundled as part of the CIMC image. When you upgrade the CIMC, if a newer firmware version is available for the FlexFlash controller, the controller can no longer be managed, and the FlexFlash inventory displays the Controller State as Waiting For User Action and the Controller
Health as Old Firmware Running . To upgrade the FlexFlash controller firmware, you need to perform a board controller update. For more information, see the appropriate Cisco UCS B-Series Firmware Management
188
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
Configuring SD Card Support
FlexUtil Secure Digital Card Support
Guide , available at the following URL: http://www.cisco.com/en/US/products/ps10281/products_installation_and_configuration_guides_list.html
.
Limitations for the Cisco Flexible Flash Storage Controller:
• The Cisco Flexible Flash storage controller only supports 16 GB, 32 GB, and 64 GB SD cards.
• We do not recommend using an SD card from a rack server in a blade server, or using an SD card from a blade server in a rack server. Switching SD cards between server types might result in data loss from the SD card.
• Some Cisco UCS C-Series rack-mount servers have SD cards with four partitions: HV, HUU, SCU, and
Drivers. Only the HV partition is visible in Cisco UCS Manager. You can migrate a four-partition SD card to a single HV partition card with a FlexFlash scrub policy.
• The FlexFlash controller does not support RAID-1 sync (mirror rebuild). If the SD cards are in a degraded
RAID state, or if any metadata errors are reported by the controller, you must run the FlexFlash scrub policy to pair the cards for RAID. For more information about the FlexFlash scrub policy, see
Server-Related Policies . The following conditions might result in degraded RAID or metadata errors:
• Inserting a new or used SD card in one slot, when the server already has an SD card populated in the second slot.
• Inserting two SD cards from different servers.
• The server firmware version must be at 2.2(1a) or higher.
FlexUtil Secure Digital Card Support
The C-Series M5 Rack-Mount servers support a Micro-SD (FlexUtil) memory card for storage. UCS Manager however does not provide management support for Micro-SD card.
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
189
FlexUtil Secure Digital Card Support
Configuring SD Card Support
190
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
C H A P T E R
12
Mini Storage
•
Mini Storage
The mini storage slot is a new slot that is present on the Cisco UCS M5 blade and rack servers. This slot can be empty, populated with an SD storage module, or populated with an M.2 SATA module.
Note Cisco UCS Manager does not support micro-SD card.
The mini storage SD module consists of an in-built SD controller and two SD cardslots. These cards have
RAID 1 capability.
The mini M.2 SATA module consists of two SATA slots. The PCH controller present on the server controls the SATA drives on this module.
Starting with 4.0(4a), Cisco UCS Manager supports Cisco boot optimized M.2 Raid controller based off
Marvell 88SE92xx PCIe to SATA 6Gb/s controller (UCS-M2-HWRAID) for mini storage.
You can use Cisco UCS Manager to inventory and manage the mini storage modules.
Viewing Mini Storage Properties
Mini storage modules are supported only on M5 and higher servers.
SUMMARY STEPS
1.
UCS-A# scope server [ chassis-num / server-num | dynamic-uuid ]
2.
UCS-A /chassis/server # show mini-storage [ detail ]
DETAILED STEPS
Step 1
Command or Action
UCS-A# scope server [ chassis-num / server-num | dynamic-uuid ]
Purpose
Enters server mode for the specified server.
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
191
Mini Storage
Viewing the Storage Controller for the Mini Storage
Step 2
Command or Action
UCS-A /chassis/server # show mini-storage [ detail ]
Purpose
Displays detailed information about the mini storage module for the specified server.
Example
This example displays detailed information about the mini storage module for server 6:
UCS-A# scope server 1/6
UCS-A /chassis/server # show mini-storage detail
Mini Storage Module:
ID: 1
Type: M2
Model: UCS-MSTOR-M2
Vendor: Cisco Systems Inc
HW Rev: 0
Serial: FCH2050JDHM
VID: V00
Part Number: 73-17926-04
Product Name: Cisco UCS Mini-Storage Carrier for M.2
Caption: Cisco UCS Mini-Storage Carrier for M.2 (holds up to 2)
Description: Dual M.2 Mini-Storage Carrier (holds up to 2 M.2 modules)
Viewing the Storage Controller for the Mini Storage
Mini storage modules are supported only on M5 and higher servers.
SUMMARY STEPS
1.
UCS-A# scope server [ chassis-num / server-num | dynamic-uuid ]
2.
UCS-A /chassis/server # scope mini-storage id m2 | sd
3.
UCS-A /chassis/server/mini-storage # show referenced-controller [ detail ]
DETAILED STEPS
Step 1
Step 2
Command or Action
UCS-A# scope server [ chassis-num / server-num | dynamic-uuid ]
UCS-A /chassis/server # scope mini-storage id m2 | sd
Step 3 UCS-A /chassis/server/mini-storage # referenced-controller [ detail ] show
Purpose
Enters server mode for the specified server.
Enters mini-storage mode for the specified server and mini storage card type.
Displays information about the storage controller referenced by the mini storage module for the specified server.
Example
This example displays information about the storage controller for the M.2 mini storage card in server
6:
192
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
Mini Storage
Viewing the Storage Controller for the Mini Storage
UCS-A# scope server 1/6
UCS-A /chassis/server # scope mini-storage 1 m2
UCS-A /chassis/server/mini-storage # show referenced-controller detail
Referenced Controller:
ID: 1
Type: PCH
This example displays information about the storage controller for the SD mini storage card in server
3:
UCS-A# scope server 1/3
UCS-A /chassis/server # scope mini-storage 1 sd
UCS-A /chassis/server/mini-storage # show referenced-controller detail
Referenced Controller:
ID: 1
Type: PCH
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
193
Viewing the Storage Controller for the Mini Storage
Mini Storage
194
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
C H A P T E R
13
SED Security Policies
•
Security Policies for Self-Encrypting Drives, on page 195
•
Security Flags of the Controller and Disk, on page 196
•
Secure Data Deletion, on page 196
•
Managing Local Security Policies, on page 197
•
KMIP Client Certificate Policy, on page 202
•
Managing Remote Security Policies, on page 206
•
Securing an Existing Virtual Drive, on page 211
•
Enabling Security on a Disk, on page 212
•
Erasing a Secure Disk, on page 213
•
Disabling Security on a Controller, on page 214
•
Unlocking a Locked Disk , on page 215
•
Erasing a Secure Foreign Configuration Disk, on page 216
•
Displaying the Security Flags of a Controller , on page 217
•
Displaying the Security Flags of a Local Disk , on page 219
•
Displaying the Security Flags of a Virtual Drive , on page 221
Security Policies for Self-Encrypting Drives
Self-Encrypting Drives (SEDs) have special hardware that encrypts incoming data and decrypts outgoing data in real-time. The data on the disk is always encrypted in the disk and stored in the encrypted form. The encrypted data is always decrypted on the way out of the disk. A media encryption key controls this encryption and decryption. This key is never stored in the processor or memory. Cisco UCS Manager supports SED security policies on Cisco UCS C-Series servers, B-Series M5 servers, and S-Series servers.
SEDs must be locked by providing a security key. The security key, which is also known as Key-Encryption
Key or an authentication passphrase, is used to encrypt the media encryption key. If the disk is not locked, no key is required to fetch the data.
Cisco UCS Manager enables you to configure security keys locally or remotely. When you configure the key locally, you must remember the key. If you forget the key, it cannot be retrieved, and the data is lost. You can configure the key remotely by using a key management server (also known as KMIP server). This method addresses the issues related to safe-keeping and retrieval of the keys in the local management.
The encryption and decryption for SEDs is done through the hardware. Thus, it does not affect the overall system performance. SEDs reduce the disk retirement and redeployment costs through instantaneous cryptographic erasure. Cryptographic erasure is done by changing the media encryption key. When the media
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
195
SED Security Policies
Security Flags of the Controller and Disk encryption key of a disk is changed, the data on the disk cannot be decrypted, and is immediately rendered unusable. With Cisco UCS Manager Release 3.1(3), SEDs offer disk theft protection for C-Series and S-Series servers. For HX servers, SEDs offer node theft protection. Cisco UCS Manager Release 4.0(2) extends the
SED security policies to UCS B-Series M5 servers.
Security Flags of the Controller and Disk
Security flags indicate the current security status of the storage controller and disks.
The storage controller and disks have the following security flags:
• Security Capable—Indicates that the controller or disk is capable of supporting SED management.
• Security Enable—Indicates that the security-key is programmed on the controller or disk, and security is enabled on the device. This flag is set when you configure a security policy and associate it to a server, making the controller and disk secure. This flag is not set on an HX device.
• Secured—Indicates that the security-key is programmed on the controller or disk, and security is enabled on the HX device.
The following security flags are exclusive to storage disks:
• Locked—Indicates that the disk key does not match the key on the controller. This happens when you move disks across servers that are programmed with different keys. The data on a locked disk is inaccessible and the operating system cannot use the disk. To use this disk, you must either unlock the disk or secure erase the foreign configuration.
• Foreign Secured—Indicates that a secure disk is in foreign configuration. This happens when you unlock a locked disk with the right key, but the disk is in a foreign configuration state and the data on it is encrypted. To use this disk, you can either import the foreign configuration or clear the foreign config.
Secure Data Deletion
The Commission Regulation (EU) 2019/424 requires that data be securely disposed of.
Secure data disposal is accomplished by using commonly available tools that erase the data from the various/drives, memory, and storage in the Cisco UCS servers and reset them to factory settings.
Secure data deletion for compliance with Commission Regulation (EU) 2019/424 is supported for the followingCisco UCS servers:
• Cisco UCS B200
• Cisco UCS B480
• Cisco UCS C125
• Cisco UCS C220
• Cisco UCS C240
• Cisco UCS C480
• Cisco UCS S3260
196
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
SED Security Policies
Managing Local Security Policies
You must be familiar with what devices are present in your UCS server and run the appropriate tools for secure data deletion. In some cases, you may need to run multiple tools.
Full instructions on how to securely erase data are available at: https://www.cisco.com/web/dofc/18794277.pdf
.
Managing Local Security Policies
Creating a Local Security Policy
SUMMARY STEPS
1.
UCS-A # scope org
2.
UCS-A /org # create storage-profile storage-profile-name
3.
UCS-A /org/storage-profile* # create security
4.
UCS-A /org/storage-profile/security* # create drive-security
5.
UCS-A /org/storage-profile/security/drive-security* # create local
6.
UCS-A /org/storage-profile/security/drive-security/local* # set security-key security-key
7.
UCS-A /org/storage-profile/security/drive-security/local* # commit-buffer
DETAILED STEPS
Step 1
Step 2
Command or Action
UCS-A # scope org
Purpose
Enters the root organization mode.
UCS-A /org # create storage-profile storage-profile-name Creates a storage profile with the specified name at the organization level and enters the storage-profile configuration mode.
Step 3
Step 4
Step 5
Step 6
Step 7
UCS-A /org/storage-profile* # create security
UCS-A /org/storage-profile/security* # create drive-security
UCS-A /org/storage-profile/security/drive-security* # create local
Creates a security policy for the specified storage profile and enters the security policy mode.
Creates a drive security policy for the specified storage profile security and enters the drive security policy mode.
Creates a local security policy for the specified storage profile and enters the local policy mode.
UCS-A /org/storage-profile/security/drive-security/local*
# set security-key security-key
Sets the specified security key for the local policy. The security key must have 32 characters.
UCS-A /org/storage-profile/security/drive-security/local*
# commit-buffer
Commits the transaction to the system configuration.
Example
This example show how to create a local security policy with a security key:
UCS-A# scope org
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
197
SED Security Policies
Modifying the Security Key of a Local Security Policy
UCS-A /org # create storage-profile stp-demo
UCS-A /org/storage-profile* # create security
UCS-A /org/storage-profile/security* # create drive-security
UCS-A /org/storage-profile/security/drive-security* # create local
UCS-A /org/storage-profile/security/drive-security/local* # set security-key thereare32charactersinthisseckey
UCS-A /org/storage-profile/security/drive-security/local* # commit-buffer
UCS-A /org/storage-profile/security/drive-security/local #
Modifying the Security Key of a Local Security Policy
SUMMARY STEPS
1.
UCS-A # scope org
2.
UCS-A /org # scope storage-profile storage-profile-name
3.
UCS-A /org/storage-profile # scope security
4.
UCS-A /org/storage-profile/security # scope drive-security
5.
UCS-A /org/storage-profile/security/drive-security # scope local
6.
UCS-A /org/storage-profile/security/drive-security/local # set deployed-security-key existing-security-key
7.
UCS-A /org/storage-profile/security/drive-security/local* # set security-key new-security-key
8.
UCS-A /org/storage-profile/security/drive-security/local* # commit-buffer
DETAILED STEPS
Step 1
Step 2
Command or Action
UCS-A # scope org
Step 3
Purpose
Enters the root organization mode.
UCS-A /org # scope storage-profile storage-profile-name Enters the storage-profile configuration mode for the specified storage profile.
UCS-A /org/storage-profile # scope security Enters the security policy mode for the specified storage profile.
Step 4
Step 5
Step 6
Step 7
Step 8
UCS-A /org/storage-profile/security # scope drive-security Enters the drive security policy mode for the specified storage profile security.
UCS-A /org/storage-profile/security/drive-security # scope local
Enters the local policy mode for the the specified storage profile.
UCS-A /org/storage-profile/security/drive-security/local #
set deployed-security-key existing-security-key
Specifies the existing key deployed on the server to configure a new key.
UCS-A /org/storage-profile/security/drive-security/local*
# set security-key new-security-key
Sets the new security key for the local policy.
UCS-A /org/storage-profile/security/drive-security/local*
# commit-buffer
Commits the transaction to the system configuration
198
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
SED Security Policies
Modifying the Security Policy from Local to Remote
Example
This example shows how to modify the security key of a local security policy:
UCS-A# scope org
UCS-A /org # scope storage-profile stp-demo
UCS-A /org/storage-profile # scope security
UCS-A /org/storage-profile/security # scope drive-security
UCS-A /org/storage-profile/security/drive-security # scope local
UCS-A /org/storage-profile/security/drive-security/local # set deployed-security-key thereare32charactersinthisseckey
UCS-A /org/storage-profile/security/drive-security/local* # set security-key thereare32charactersinthisnewkey
UCS-A /org/storage-profile/security/drive-security/local* # commit-buffer
UCS-A /org/storage-profile/security/drive-security/local #
Modifying the Security Policy from Local to Remote
Before you begin
Ensure that you have created a KMIP client certificate policy.
SUMMARY STEPS
1.
UCS-A # scope org
2.
UCS-A /org # scope storage-profile storage-profile-name
3.
UCS-A /org/storage-profile # scope security
4.
UCS-A /org/storage-profile/security # scope drive-security
5.
UCS-A /org/storage-profile/security/drive-security # create remote
6.
UCS-A /org/storage-profile/security/drive-security/remote* # set deployed-security-key existing-security-key
7.
UCS-A /org/storage-profile/security/drive-security/remote* # set primary-server primary-server-name
8.
(Optional) UCS-A /org/storage-profile/security/drive-security/remote* # set secondary-server secondary-server-name
9.
(Optional) UCS-A /org/storage-profile/security/drive-security/remote* # set port kmip-server-port-number
10.
UCS-A /org/storage-profile/security/drive-security/remote* # set server-certificate
11.
(Optional) UCS-A /org/storage-profile/security/drive-security/remote* # set timeout timeout-seconds
12.
UCS-A /org/storage-profile/security/drive-security/remote* # commit-buffer
13.
UCS-A /org/storage-profile/security/drive-security/remote # exit
14.
UCS-A /org/storage-profile/security/drive-security # delete local
15.
UCS-A /org/storage-profile/security/drive-security* # commit-buffer
DETAILED STEPS
Step 1
Command or Action
UCS-A # scope org
Purpose
Enters the root organization mode.
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
199
SED Security Policies
Modifying the Security Policy from Local to Remote
Step 12
Step 13
Step 14
Step 15
Step 2
Step 3
Step 4
Step 5
Step 6
Step 7
Step 8
Step 9
Step 10
Step 11
Command or Action Purpose
UCS-A /org # scope storage-profile storage-profile-name Enters the storage-profile configuration mode for the selected storage profile.
UCS-A /org/storage-profile # scope security
UCS-A /org/storage-profile/security # drive-security scope
Enters the security policy mode for the specified storage profile.
Enters the drive security policy mode for the specified storage profile security.
UCS-A /org/storage-profile/security/drive-security # create remote
Creates and enters the remote policy mode.
UCS-A /org/storage-profile/security/drive-security/remote*
# set deployed-security-key existing-security-key
Specifies the existing key deployed on the server.
UCS-A /org/storage-profile/security/drive-security/remote*
# set primary-server primary-server-name
Sets the primary server hostname or IP address.
(Optional) UCS-A
/org/storage-profile/security/drive-security/remote* # set
secondary-server secondary-server-name
Sets the secondary server hostname or IP address.
(Optional) UCS-A
/org/storage-profile/security/drive-security/remote* # set
port kmip-server-port-number
Sets the port number of the KMIP server. KMIP server port numbers can range from 1024 to 65535.
UCS-A /org/storage-profile/security/drive-security/remote*
# set server-certificate
Sets the KMIP certificate to the remote security policy.
(Optional) UCS-A
/org/storage-profile/security/drive-security/remote* # set
timeout timeout-seconds
Sets the number of seconds in which communication between the storage and the KMIP server times out.
Timeout can range from 5 seconds to 20 seconds.
UCS-A /org/storage-profile/security/drive-security/remote*
# commit-buffer
Commits the transaction to the system configuration.
UCS-A /org/storage-profile/security/drive-security/remote
# exit
Enters the drive security policy mode.
UCS-A /org/storage-profile/security/drive-security # delete local
Deletes the existing local security policy.
UCS-A /org/storage-profile/security/drive-security* # commit-buffer
Commits the transaction to the system configuration.
Example
This example shows how to modify a security policy from local to remote:
UCS-A # scope org
UCS-A /org # scope storage-profile stp-demo
UCS-A /org/storage-profile # scope security
UCS-A /org/storage-profile/security # scope drive-security
UCS-A /org/storage-profile/security/drive-security # create remote
200
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
SED Security Policies
Inserting a Secured Disk into a Server with a Local Security Policy
UCS-A /org/storage-profile/security/drive-security/remote* # set deployed-security-key thereare32charactersinthisseckey
UCS-A /org/storage-profile/security/drive-security/remote* # set primary-server 10.10.10.1
UCS-A /org/storage-profile/security/drive-security/remote* # set secondary-server 10.10.10.2
UCS-A /org/storage-profile/security/drive-security/remote* # set port 5696
UCS-A /org/storage-profile/security/drive-security/remote* # set server-certificate
Enter lines one at a time. Enter ENDOFBUF to finish. Press ^C to abort.
Prompt Certificate:
>-----BEGIN CERTIFICATE-----
MIIEEDCCAvigAwIBAgIGALOfZVDsMA0GCSqGSIb3DQEBCwUAMIGQMSowKAYDVQQD
EyFDRyBDQSBTIG9uIHZvcm1ldHJpY2RzbS5jaXNjby5jb20xFTATBgNVBAsTDFNh dmJ1U3RvcmRldjEWMBQGA1UEChMNQ2lzY28gU3lzdGVtczERMA8GA1UEBxMIU2Fu
IEpvc2UxEzARBgNVBAgTCkNhbGlmb3JuaWExCzAJBgNVBAYTAlVTMB4XDTE2MDkw
NzE5MzMwMVoXDTI2MDkwOTE5MzMwMVowgZAxKjAoBgNVBAMTIUNHIENBIFMgb24g dm9ybWV0cmljZHNtLmNpc2NvLmNvbTEVMBMGA1UECxMMU2F2YnVTdG9yZGV2MRYw
FAYDVQQKEw1DaXNjbyBTeXN0ZW1zMREwDwYDVQQHEwhTYW4gSm9zZTETMB>EGA1UE
CBMKQ2FsaWZvcm5pYTELMAkGA1UEBhMCVVMwggEiMA0GCSqGSIb3DQEBAQUAA4IB
DwAwggEKAoIBAQDhX2UdIV>TQTchGo1FjAc5u1W9zAo/YkjD22ANpbEPiAmgWL97c
Xwj7yzArflrZ2kWvQCm4f6AdLOFUWzbuo+Fxd3rurd>w6BhJXdLj8Piq8094PqCLp qdUF83SsRVVbCXHxOqdk9jsSQrvTcV4PloNrelMLq/mOqsaODs+us4ng7sMDtGXv
LeKFC8DUEm0GlGQACwiJ3s9O4+P2CI/d4P/>EyWwqABf3YJmAI1EQyUnoTwrg6EgY
ZvcpHsmjXnbBZrL+ON7FBcbrTanvjyJxE6tFf5cRPGhymfna7Fd3lfVwZCcGIoR+
EOIAwgetzIRM6FzMiV2/tDT8STo/oo5Tg3dDAgMBAAGjbj>BsMBIGA1UdEwEB/wQI
MAYBAf8CAQAwDgYDVR0PAQH/>>>>>>>>>BAQDAgEGMB0GA1UdDgQWBBRnYyFiAK2lEDZJNC0Y
VlIqMgiUJDAnBgNVHSMEIDAegBRnYyFiAK2lEDZJNC0YVlIqMgiUJIIGALOfZVDs
MA0GCSqGSIb3DQEBCwUAA4IBAQAfhB2+Ft8V2ELAFa7PcG/rU09ux7LYcCjt3STa mzKdZ7Rn5COvknKrJX+EefT7xl03CQXT9aeSAddQUOCy8fhiPoaMFrlTgs1hdS0p
NJvfxV6QCun2UMRSuxWfG>0QFfofnXeIGkAmEYOpUdArSOTbtt4v6Lja1A+KEsvWW
5KaVemo2nsd+iD0IPCOhpShAgaAwpnYUq9mLfVgvV07Z+hmkuOIQTZ2+h+pJQtE0
+U5qaTts4pMXpqQPjlid0NMuaPug1SpSD7KBsjwR1SzehzPdns16uprmvWa3VBk3
OK6y55FoIu+Wg9i/8kmfkghyGwTfo6weEKbleuVwupvpriMF>
-----END CERTIFICATE-----
UCS-A /org/storage-profile/security/drive-security/remote* # commit-buffer
UCS-A /org/storage-profile/security/drive-security/remote # exit
UCS-A /org/storage-profile/security/drive-security # delete local
UCS-A /org/storage-profile/security/drive-security* # commit-buffer
UCS-A /org/storage-profile/security/drive-security #
Inserting a Secured Disk into a Server with a Local Security Policy
When you insert a secured disk into a server, one of the following will occur:
• The security-key on the drive matches that of the server and it automatically gets unlocked.
• The security-key on the disk is different from the security-key on the server. The disk will appear as a locked disk. You can do one of the following on a locked disk:
• Erase the secure foreign configuration to delete all data on the disk.
• Unlock the disk by providing the correct key of the disk. After unlocking the disk, the disk will be in the Foreign Secured state. You must immediately import or clear the foreign configuration for these disks.
Note If you unlock another set of disks before importing the foreign configuration for the current set of disks, the current set of disks become locked again and go in to the Locked state.
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
201
SED Security Policies
KMIP Client Certificate Policy
KMIP Client Certificate Policy
You can configure the key remotely by using a key management server, which is also known as KMIP server.
You must create a KMIP client certificate policy before creating a remote policy. The hostname that is used for generating the certificate is the serial number of the KMIP server.
You can create a certificate policy from two separate scopes:
• Global scope—You can initially create a global certificate policy in this scope. Any modification of the certificate in this scope will not result in the regeneration of the certificate.
• Server scope—You can create or modify a certificate policy in this scope. This will result in a regeneration of the certificates. Such a certificate is specific to the server, and, for this server, overrides the global certificate.
After you create a KMIP client certificate policy, do one of the following:
• Copy the generated certificate to the KMIP Server.
• Use the generated Certificate Signing Request to get a CA-signed certificate. Copy this CA-signed certificate to the CIMC.
Creating a Global KMIP Client Certificate Policy
SUMMARY STEPS
1.
UCS-A # scope security
2.
UCS-A /security # create kmip-client-cert-policy
3.
UCS-A /security/kmip-client-cert-policy* # set country country-code
4.
UCS-A /security/kmip-client-cert-policy* # set locality locality-code
5.
UCS-A /security/kmip-client-cert-policy* # set org-name org-name
6.
UCS-A /security/kmip-client-cert-policy* # set org-unit-name unit-name
7.
UCS-A /security/kmip-client-cert-policy* # set state state-code
8.
(Optional) UCS-A /security/kmip-client-cert-policy* # set email email-address
9.
(Optional) UCS-A /security/kmip-client-cert-policy* # set validity days
10.
UCS-A /security/kmip-client-cert-policy* # commit-buffer
11.
UCS-A /security/kmip-client-cert-policy # show
DETAILED STEPS
Step 1
Step 2
Step 3
Command or Action
UCS-A # scope security
Purpose
Enters the security mode.
UCS-A /security # create kmip-client-cert-policy Creates the KMIP certificate policy and enters the KMIP client certificate policy mode.
UCS-A /security/kmip-client-cert-policy* # set country country-code
Specifies the country code for the KMIP certificate policy.
The country code must contain 2 letters in upper case.
202
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
SED Security Policies
Creating a Global KMIP Client Certificate Policy
Step 4
Step 5
Step 6
Step 7
Step 8
Step 9
Step 10
Step 11
Command or Action
UCS-A /security/kmip-client-cert-policy* # set locality locality-code
Purpose
Specifies the name of the locality or city for the KMIP certificate policy. Enter up to 32 characters for the locality name.
UCS-A /security/kmip-client-cert-policy* # set org-name org-name
Specifies the organization name requesting the KMIP certificate policy. Enter up to 32 characters for the organization name.
UCS-A /security/kmip-client-cert-policy* # set
org-unit-name unit-name
UCS-A /security/kmip-client-cert-policy* # state-code set state
Specifies the organizational unit name requesting the KMIP certificate policy. Enter up to 64 characters for the organizational unit name.
Specifies the name of the state, province, or county for the
KMIP certificate policy. Enter up to 32 characters for the state name.
(Optional) UCS-A /security/kmip-client-cert-policy* # set
email email-address
Specifies the email address associated with the request.
(Optional) UCS-A /security/kmip-client-cert-policy* # set
validity days
Specifies the validity of the certificate in number of days.
The validity can range between 365 days and 3650 days.
UCS-A /security/kmip-client-cert-policy* # commit-buffer Commits the transaction to the system configuration.
UCS-A /security/kmip-client-cert-policy # show Displays details of the KMIP certificate policy.
Example
This example shows how to create a KMIP certificate policy.
UCS-A# scope security
UCS-A /security # create kmip-client-cert-policy
UCS-A /security/kmip-client-cert-policy* # set country IN
UCS-A /security/kmip-client-cert-policy* # set locality BLR
UCS-A /security/kmip-client-cert-policy* # set org-name XYZ
UCS-A /security/kmip-client-cert-policy* # set org-unit-name Ops
UCS-A /security/kmip-client-cert-policy* # set state KA
UCS-A /security/kmip-client-cert-policy* # commit-buffer
UCS-A /security/kmip-client-cert-policy # show
KMIP Client certificate policy:
Certificate request country name: IN
State, province or county (full name): KA
Locality name (eg, city): BLR
Organisation name (eg, company): XYZ
Organisational Unit Name (eg, section): Ops
Certificate request e-mail name:
Validity of certificate in number of days: 1095
UCS-A /security/kmip-client-cert-policy #
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
203
SED Security Policies
Creating a KMIP Client Certificate for a Server
Creating a KMIP Client Certificate for a Server
You can create a KMIP client certificate policy for a server. This certificate is applicable only to the specific server, and overrides the global KMIP client certificate.
The hostname that used to create the certificate when using this policy is the serial number of the server.
SUMMARY STEPS
1.
UCS-A # scope server server-number
2.
UCS-A /server # create kmip-client-cert-policy
3.
UCS-A /server/kmip-client-cert-policy* # set country country-code
4.
UCS-A /server/kmip-client-cert-policy* # set locality locality-code
5.
UCS-A /server/kmip-client-cert-policy* # set org-name org-name
6.
UCS-A /server/kmip-client-cert-policy* # set org-unit-name unit-name
7.
UCS-A /server/kmip-client-cert-policy* # set state state-code
8.
(Optional) UCS-A /server/kmip-client-cert-policy* # set email email-address
9.
(Optional) UCS-A /server/kmip-client-cert-policy* # set validity days
10.
UCS-A /server/kmip-client-cert-policy* # commit-buffer
11.
UCS-A /server/kmip-client-cert-policy # show
DETAILED STEPS
Step 1
Step 2
Step 3
Step 4
Step 5
Step 6
Step 7
Command or Action
UCS-A # scope server server-number
Purpose
Enters the server configuration mode for the specified server.
UCS-A /server # create kmip-client-cert-policy
UCS-A /server/kmip-client-cert-policy* # set country country-code
UCS-A /server/kmip-client-cert-policy* # locality-code set locality
Creates the KMIP certificate policy and enters the KMIP client certificate policy mode.
Specifies the country code for the KMIP certificate policy.
The country code must contain 2 letters in upper case.
UCS-A /server/kmip-client-cert-policy* # set org-name org-name
Specifies the organization name requesting the KMIP certificate policy. Enter up to 32 characters for the organization name.
UCS-A /server/kmip-client-cert-policy* # set
org-unit-name unit-name
Specifies the name of the locality or city for the KMIP certificate policy. Enter up to 32 characters for the locality name.
UCS-A /server/kmip-client-cert-policy* # state-code set state
Specifies the organizational unit name requesting the KMIP certificate policy. Enter up to 64 characters for the organizational unit name.
Specifies the name of the state, province, or county for the
KMIP certificate policy. Enter up to 32 characters for the state name.
Step 8 (Optional) UCS-A /server/kmip-client-cert-policy* #
email email-address set Specifies the email address associated with the request.
204
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
SED Security Policies
Creating a KMIP Client Certificate for a Server
Step 9
Step 10
Step 11
Command or Action
(Optional) UCS-A /server/kmip-client-cert-policy* # set
validity days
Purpose
Specifies the validity of the certificate in number of days.
The validity can range between 365 days and 3650 days.
UCS-A /server/kmip-client-cert-policy* # commit-buffer Commits the transaction to the system configuration.
UCS-A /server/kmip-client-cert-policy # show Displays details of the KMIP certificate.
Example
This example shows how to create a KMIP certificate on a rack-mount server.
UCS-A# scope server 5
UCS-A /server # create kmip-client-cert-policy
UCS-A /server/kmip-client-cert-policy* # set country IN
UCS-A /server/kmip-client-cert-policy* # set locality BLR
UCS-A /server/kmip-client-cert-policy* # set org-name XYZ
UCS-A /server/kmip-client-cert-policy* # set org-unit-name Ops
UCS-A /server/kmip-client-cert-policy* # set state KA
UCS-A /server/kmip-client-cert-policy* # commit-buffer
UCS-A /server/kmip-client-cert-policy* # show
KMIP Client certificate policy:
Certificate request country name: IN
State, province or county (full name): KA
Locality name (eg, city): BLR
Organisation name (eg, company): XYZ
Organisational Unit Name (eg, section): Ops
Certificate request e-mail name:
Validity of certificate in number of days: 1095
UCS-A /server/kmip-client-cert-policy #
This example shows how to create a KMIP certificate on a blade server.
UCS-A# scope server 1/5
UCS-A chassis/server # create kmip-client-cert-policy
UCS-A chassis/server/kmip-client-cert-policy* # set country IN
UCS-A chassis/server/kmip-client-cert-policy* # set locality BLR
UCS-A chassis/server/kmip-client-cert-policy* # set org-name XYZ
UCS-A chassis/server/kmip-client-cert-policy* # set org-unit-name Ops
UCS-A chassis/server/kmip-client-cert-policy* # set state KA
UCS-A chassis/server/kmip-client-cert-policy* # commit-buffer
UCS-A chassis/server/kmip-client-cert-policy* # show
KMIP Client certificate policy:
Certificate request country name: IN
State, province or county (full name): KA
Locality name (eg, city): BLR
Organisation name (eg, company): XYZ
Organisational Unit Name (eg, section): Ops
Certificate request e-mail name:
Validity of certificate in number of days: 1095
UCS-A /server/kmip-client-cert-policy #
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
205
SED Security Policies
Managing Remote Security Policies
Managing Remote Security Policies
Creating a Remote Security Policy
Before you begin
Ensure that you have created a KMIP client certificate policy.
SUMMARY STEPS
1.
UCS-A # scope org
2.
UCS-A /org # scope storage-profile storage-profile-name
3.
UCS-A /org/storage-profile # create security
4.
UCS-A /org/storage-profile/security* # create drive-security
5.
UCS-A /org/storage-profile/security/drive-security* # create remote
6.
UCS-A /org/storage-profile/security/drive-security/remote* # set primary-server primary-server-name
7.
(Optional) UCS-A /org/storage-profile/security/drive-security/remote* # set secondary-server secondary-server-name
8.
(Optional) UCS-A /org/storage-profile/security/drive-security/remote* # set port kmip-server-port-number
9.
UCS-A /org/storage-profile/security/drive-security/remote* # set server-certificate
10.
(Optional) UCS-A /org/storage-profile/security/drive-security/remote* # set timeout timeout-seconds
11.
(Optional) UCS-A /org/storage-profile/security/drive-security/remote* # create login
12.
(Optional) UCS-A /org/storage-profile/security/drive-security/remote/login* # set username username
13.
(Optional) UCS-A /org/storage-profile/security/drive-security/remote/login* # set password password
14.
UCS-A /org/storage-profile/security/drive-security/remote/login* # commit-buffer
DETAILED STEPS
Step 1
Step 2
Command or Action
UCS-A # scope org
Step 3
Step 4
Purpose
Enters the root organization mode.
UCS-A /org # scope storage-profile storage-profile-name Enters the storage-profile configuration mode for the selected storage profile.
UCS-A /org/storage-profile # create security Creates and enters the security mode.
Step 5
Step 6
UCS-A /org/storage-profile/security* # create drive-security
UCS-A /org/storage-profile/security/drive-security* # create remote
Creates and enters the drive-security mode.
Creates and enters the remote policy mode.
UCS-A /org/storage-profile/security/drive-security/remote*
# set primary-server primary-server-name
Sets the primary server hostname or IP address.
206
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
SED Security Policies
Creating a Remote Security Policy
Step 7
Step 8
Step 9
Step 10
Step 11
Step 12
Step 13
Step 14
Command or Action Purpose
(Optional) UCS-A
/org/storage-profile/security/drive-security/remote* # set
secondary-server secondary-server-name
Sets the secondary server hostname or IP address.
(Optional) UCS-A
/org/storage-profile/security/drive-security/remote* # set
port kmip-server-port-number
Sets the port number of the KMIP server. KMIP server port numbers can range from 1024 to 65535.
UCS-A /org/storage-profile/security/drive-security/remote*
# set server-certificate
Sets the KMIP certificate to the remote security policy.
(Optional) UCS-A
/org/storage-profile/security/drive-security/remote* # set
timeout timeout-seconds
Sets the number of seconds in which communication between the storage and the KMIP server times out.
Timeout can range from 5 seconds to 20 seconds.
(Optional) UCS-A
/org/storage-profile/security/drive-security/remote* # create login
Creates the login details for the KMIP server and enters the login mode.
(Optional) UCS-A
/org/storage-profile/security/drive-security/remote/login*
# set username username
Sets the username to log into the KMIP server.
(Optional) UCS-A
/org/storage-profile/security/drive-security/remote/login*
# set password password
Sets the password to log into the KMIP server.
UCS-A
/org/storage-profile/security/drive-security/remote/login*
# commit-buffer
Commits the transaction to the system configuration.
Example
UCS-A # scope org
UCS-A /org # scope storage-profile stp-demo
UCS-A /org/storage-profile # create security
UCS-A /org/storage-profile/security* # create drive-security
UCS-A /org/storage-profile/security/drive-security* # create remote
UCS-A /org/storage-profile/security/drive-security/remote* # set primary-server 10.10.10.1
UCS-A /org/storage-profile/security/drive-security/remote* # set secondary-server 10.10.10.2
UCS-A /org/storage-profile/security/drive-security/remote* # set port 5696
UCS-A /org/storage-profile/security/drive-security/remote* # set server-certificate
Enter lines one at a time. Enter ENDOFBUF to finish. Press ^C to abort.
Prompt Certificate:
>-----BEGIN CERTIFICATE-----
MIIEEDCCAvigAwIBAgIGALOfZVDsMA0GCSqGSIb3DQEBCwUAMIGQMSowKAYDVQQD
EyFDRyBDQSBTIG9uIHZvcm1ldHJpY2RzbS5jaXNjby5jb20xFTATBgNVBAsTDFNh dmJ1U3RvcmRldjEWMBQGA1UEChMNQ2lzY28gU3lzdGVtczERMA8GA1UEBxMIU2Fu
IEpvc2UxEzARBgNVBAgTCkNhbGlmb3JuaWExCzAJBgNVBAYTAlVTMB4XDTE2MDkw
NzE5MzMwMVoXDTI2MDkwOTE5MzMwMVowgZAxKjAoBgNVBAMTIUNHIENBIFMgb24g dm9ybWV0cmljZHNtLmNpc2NvLmNvbTEVMBMGA1UECxMMU2F2YnVTdG9yZGV2MRYw
FAYDVQQKEw1DaXNjbyBTeXN0ZW1zMREwDwYDVQQHEwhTYW4gSm9zZTETMB>EGA1UE
CBMKQ2FsaWZvcm5pYTELMAkGA1UEBhMCVVMwggEiMA0GCSqGSIb3DQEBAQUAA4IB
DwAwggEKAoIBAQDhX2UdIV>TQTchGo1FjAc5u1W9zAo/YkjD22ANpbEPiAmgWL97c
Xwj7yzArflrZ2kWvQCm4f6AdLOFUWzbuo+Fxd3rurd>w6BhJXdLj8Piq8094PqCLp
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
207
SED Security Policies
Modifying a Remote Security Key qdUF83SsRVVbCXHxOqdk9jsSQrvTcV4PloNrelMLq/mOqsaODs+us4ng7sMDtGXv
LeKFC8DUEm0GlGQACwiJ3s9O4+P2CI/d4P/>EyWwqABf3YJmAI1EQyUnoTwrg6EgY
ZvcpHsmjXnbBZrL+ON7FBcbrTanvjyJxE6tFf5cRPGhymfna7Fd3lfVwZCcGIoR+
> EOIAwgetzIRM6FzMiV2/tDT8STo/oo5Tg3dDAgMBAAGjbj>BsMBIGA1UdEwEB/wQI
MAYBAf8CAQAwDgYDVR0PAQH/>>>>>>>>>BAQDAgEGMB0GA1UdDgQWBBRnYyFiAK2lEDZJNC0Y
VlIqMgiUJDAnBgNVHSMEIDAegBRnYyFiAK2lEDZJNC0YVlIqMgiUJIIGALOfZVDs
MA0GCSqGSIb3DQEBCwUAA4IBAQAfhB2+Ft8V2ELAFa7PcG/rU09ux7LYcCjt3STa mzKdZ7Rn5COvknKrJX+EefT7xl03CQXT9aeSAddQUOCy8fhiPoaMFrlTgs1hdS0p
NJvfxV6QCun2UMRSuxWfG>0QFfofnXeIGkAmEYOpUdArSOTbtt4v6Lja1A+KEsvWW
5KaVemo2nsd+iD0IPCOhpShAgaAwpnYUq9mLfVgvV07Z+hmkuOIQTZ2+h+pJQtE0
+U5qaTts4pMXpqQPjlid0NMuaPug1SpSD7KBsjwR1SzehzPdns16uprmvWa3VBk3
OK6y55FoIu+Wg9i/8kmfkghyGwTfo6weEKbleuVwupvpriMF>
-----END CERTIFICATE-----
UCS-A /org/storage-profile/security/drive-security/remote* # create login
UCS-A /org/storage-profile/security/drive-security/remote/login* # set username user1
UCS-A /org/storage-profile/security/drive-security/remote/login* # set password Password
UCS-A /org/storage-profile/security/drive-security/remote/login* # exit
UCS-A /org/storage-profile/security/drive-security/remote # exit
UCS-A /org/storage-profile/security/drive-security # show detail expand
Drive Security:
Remote:
Primary Server Name: 10.10.10.1
Secondary Server Name:10.10.10.2
KMIP Server Port: 5696
Deployed Security Key:
KMIP Server Certificate: -----BEGIN CERTIFICATE-----
MIIEEDCCAvigAwIBAgIGALOfZVDsMA0GCSqGSIb3DQEBCwUAMIGQMSowKAYDVQQD
EyFDRyBDQSBTIG9uIHZvcm1ldHJpY2RzbS5jaXNjby5jb20xFTATBgNVBAsTDFNh dmJ1U3RvcmRldjEWMBQGA1UEChMNQ2lzY28gU3lzdGVtczERMA8GA1UEBxMIU2Fu
IEpvc2UxEzARBgNVBAgTCkNhbGlmb3JuaWExCzAJBgNVBAYTAlVTMB4XDTE2MDkw
NzE5MzMwMVoXDTI2MDkwOTE5MzMwMVowgZAxKjAoBgNVBAMTIUNHIENBIFMgb24g dm9ybWV0cmljZHNtLmNpc2NvLmNvbTEVMBMGA1UECxMMU2F2YnVTdG9yZGV2MRYw
FAYDVQQKEw1DaXNjbyBTeXN0ZW1zMREwDwYDVQQHEwhTYW4gSm9zZTETMBEGA1UE
CBMKQ2FsaWZvcm5pYTELMAkGA1UEBhMCVVMwggEiMA0GCSqGSIb3DQEBAQUAA4IB
DwAwggEKAoIBAQDhX2UdIVTQTchGo1FjAc5u1W9zAo/YkjD22ANpbEPiAmgWL97c
Xwj7yzArflrZ2kWvQCm4f6AdLOFUWzbuo+Fxd3rurdw6BhJXdLj8Piq8094PqCLp qdUF83SsRVVbCXHxOqdk9jsSQrvTcV4PloNrelMLq/mOqsaODs+us4ng7sMDtGXv
LeKFC8DUEm0GlGQACwiJ3s9O4+P2CI/d4P/EyWwqABf3YJmAI1EQyUnoTwrg6EgY
ZvcpHsmjXnbBZrL+ON7FBcbrTanvjyJxE6tFf5cRPGhymfna7Fd3lfVwZCcGIoR+
EOIAwgetzIRM6FzMiV2/tDT8STo/oo5Tg3dDAgMBAAGjbjBsMBIGA1UdEwEB/wQI
MAYBAf8CAQAwDgYDVR0PAQH/BAQDAgEGMB0GA1UdDgQWBBRnYyFiAK2lEDZJNC0Y
VlIqMgiUJDAnBgNVHSMEIDAegBRnYyFiAK2lEDZJNC0YVlIqMgiUJIIGALOfZVDs
MA0GCSqGSIb3DQEBCwUAA4IBAQAfhB2+Ft8V2ELAFa7PcG/rU09ux7LYcCjt3STa mzKdZ7Rn5COvknKrJX+EefT7xl03CQXT9aeSAddQUOCy8fhiPoaMFrlTgs1hdS0p
NJvfxV6QCun2UMRSuxWfG0QFfofnXeIGkAmEYOpUdArSOTbtt4v6Lja1A+KEsvWW
5KaVemo2nsd+iD0IPCOhpShAgaAwpnYUq9mLfVgvV07Z+hmkuOIQTZ2+h+pJQtE0
+U5qaTts4pMXpqQPjlid0NMuaPug1SpSD7KBsjwR1SzehzPdns16uprmvWa3VBk3
OK6y55FoIu+Wg9i/8kmfkghyGwTfo6weEKbleuVwupvpriMF
-----END CERTIFICATE-----
Modifying a Remote Security Key
SUMMARY STEPS
1.
UCS-A # scope server server-id
2.
UCS-A /server # scope raid-controller raid-controller-id {SAS | SAT}
3.
UCS-A /server/raid-controller # set admin-state modify-remote-key
208
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
SED Security Policies
Modifying the Security Policy from Remote to Local
4.
UCS-A /server/raid-controller # commit-buffer
DETAILED STEPS
Step 1
Step 2
Step 3
Step 4
Command or Action
UCS-A # scope server server-id
Purpose
Enters the server mode for the specified server.
UCS-A /server # scope raid-controller raid-controller-id
{SAS | SAT}
Enters the RAID controller mode. Currently, Cisco UCS
Manager supports SED only on SAS controllers.
Modifies the security key of a remote security policy.
UCS-A /server/raid-controller # set admin-state modify-remote-key
UCS-A /server/raid-controller # commit-buffer Commits the transaction to the system configuration.
Example
This example shows how to modify the remote security key on the controller for a rack-mount server:
UCS-A# scope server 3
UCS-A /server # scope raid-controller 1 sas
UCS-A /server/raid-controller # set admin-state modify-remote-key
UCS-A /server/raid-controller* # commit-buffer
UCS-A /server/raid-controller #
This example shows how to modify the remote security key on the controller for a blade server:
UCS-A# scope server 1/3
UCS-A chassis/server # scope raid-controller 1 sas
UCS-A chassis/server/raid-controller # set admin-state modify-remote-key
UCS-A chassis/server/raid-controller* # commit-buffer
UCS-A chassis/server/raid-controller #
Modifying the Security Policy from Remote to Local
SUMMARY STEPS
1.
UCS-A # scope org
2.
UCS-A /org # scope storage-profile storage-profile-name
3.
UCS-A /org/storage-profile # scope security
4.
UCS-A /org/storage-profile/security # scope drive-security
5.
UCS-A /org/storage-profile/security/drive-security # delete remote
6.
UCS-A /org/storage-profile/security/drive-security* # commit-buffer
7.
UCS-A /org/storage-profile/security/drive-security # create local
8.
UCS-A /org/storage-profile/security/drive-security/local* # set security-key security-key
9.
UCS-A /org/storage-profile/security/drive-security/local* # commit-buffer
10.
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
209
SED Security Policies
Inserting a Secured Disk into a Server with a Remote Security Policy
DETAILED STEPS
Step 1
Step 2
Command or Action
UCS-A # scope org
Step 3
Step 4
Purpose
Enters the root organization mode.
UCS-A /org # scope storage-profile storage-profile-name Enters the storage-profile configuration mode for the specified storage profile.
UCS-A /org/storage-profile # scope security
UCS-A /org/storage-profile/security # drive-security scope
Enters the security policy mode for the specified storage profile.
Enters the drive security policy mode for the specified storage profile security.
Step 5
Step 6
Step 7
Step 8
Step 9
UCS-A /org/storage-profile/security/drive-security # delete remote
Deletes the existing remote security policy.
UCS-A /org/storage-profile/security/drive-security* # commit-buffer
Commits the transaction to the system configuration.
UCS-A /org/storage-profile/security/drive-security # create local
Creates and enters the local policy mode.
UCS-A /org/storage-profile/security/drive-security/local*
# set security-key security-key
Sets the security key for the local policy.
UCS-A /org/storage-profile/security/drive-security/local*
# commit-buffer
Commits the transaction to the system configuration
Step 10
Example
This example shows how to modify a security policy from remote to local:
UCS-A# scope org
UCS-A /org # scope storage-profile stp-demo
UCS-A /org/storage-profile # scope security
UCS-A /org/storage-profile/security # scope drive-security
UCS-A /org/storage-profile/security/drive-security # delete remote
UCS-A /org/storage-profile/security/drive-security* # commit-buffer
UCS-A /org/storage-profile/security/drive-security # create local
UCS-A /org/storage-profile/security/drive-security/local* # set security-key thereare32charactersinthisseckey
UCS-A /org/storage-profile/security/drive-security/local* # commit-buffer
UCS-A /org/storage-profile/security/drive-security/local #
Inserting a Secured Disk into a Server with a Remote Security Policy
When you insert a secured disk into a server with a remote security policy, the storage disk will appear as a locked disk. Do one of the following:
• Unlock the disk manually with the local key if the disk was previously locked using the local key.
210
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
SED Security Policies
Securing an Existing Virtual Drive
• Unlock using the remote KMIP server.
When you move a secured disk from a server with a local security policy to a server with a remote security policy, the disk will come up as locked. Unlock the disk manually with the local key.
Securing an Existing Virtual Drive
Before you begin
• The controller must be secure.
• The virtual drive must be in the Orphaned state.
SUMMARY STEPS
1.
UCS-A# scope server server-id
2.
UCS-A /server# scope raid-controller raid-controller-id {SAS | SAT}
3.
UCS-A /server/raid-controller# scope virtual-drive virtual-drive-id
4.
UCS-A /server/raid-controller/virtual-drive# set admin-state secure-drive-group
5.
UCS-A /server/raid-controller/virtual-drive*# commit-buffer
DETAILED STEPS
Step 1
Step 2
Command or Action
UCS-A# scope server server-id
Step 3
Step 4
Step 5
Purpose
Enters the server mode for the specified server.
UCS-A /server# scope raid-controller raid-controller-id
{SAS | SAT}
Enters the RAID controller mode.
Currently, Cisco UCS Manager supports SED only on SAS controllers.
UCS-A /server/raid-controller# scope virtual-drive virtual-drive-id
Enters the virtual drive mode for the specified orphaned virtual drive.
Secures the existing virtual drive.
UCS-A /server/raid-controller/virtual-drive# set admin-state secure-drive-group
UCS-A /server/raid-controller/virtual-drive*# commit-buffer
Commits the transaction to the system configuration.
Example
This example shows how to secure an existing virtual drive for a rack-mount server:
UCS-A# scope server 1
UCS-A /server# scope raid-controller 3 sas
UCS-A /server/raid-controller# scope virtual-drive 1000
UCS-A /server/raid-controller/virtual-drive # set admin-state secure-drive-group
UCS-A /server/raid-controller/virtual-drive*# commit-buffer
UCS-A /server/raid-controller/virtual-drive#
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
211
SED Security Policies
Enabling Security on a Disk
This example shows how to secure an existing virtual drive for a blade server:
UCS-A# scope server 1/4
UCS-A chassis/server# scope raid-controller 3 sas
UCS-A chassis/server/raid-controller# scope virtual-drive 1000
UCS-A chassis/server/raid-controller/virtual-drive # set admin-state secure-drive-group
UCS-A chassis/server/raid-controller/virtual-drive*# commit-buffer
UCS-A chassis/server/raid-controller/virtual-drive#
Enabling Security on a Disk
Before you begin
Ensure that the disk is a JBOD.
SUMMARY STEPS
1.
UCS-A# scope server server-id
2.
UCS-A /server # scope raid-controller raid-controller-id {SAS | SAT}
3.
UCS-A /server/raid-controller # scope local-disk local-disk-id
4.
UCS-A /server/raid-controller/local-disk # set admin-state enable-security
5.
UCS-A /server/raid-controller/local-disk* # commit-buffer
DETAILED STEPS
Step 1
Step 2
Step 3
Step 4
Step 5
Command or Action
UCS-A# scope server server-id
Purpose
Enters the server mode for the specified server.
UCS-A /server # scope raid-controller raid-controller-id
{SAS | SAT}
Enters the RAID controller mode.
Currently, Cisco UCS Manager supports SED only on SAS controllers.
UCS-A /server/raid-controller # scope local-disk local-disk-id
Enters the local disk configuration mode
UCS-A /server/raid-controller/local-disk # set admin-state enable-security
Enables security on a JBOD.
UCS-A /server/raid-controller/local-disk* # commit-buffer Commits the transaction to the system configuration.
Example
The example shows how to enable security on a JBOD for a rack-mount server:
UCS-A# scope server 1
UCS-A /server # scope raid-controller 3 sas
UCS-A /server/raid-controller # scope local-disk 2
212
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
SED Security Policies
Erasing a Secure Disk
UCS-A /server/raid-controller/local-disk # set admin-state enable-security
UCS-A /server/raid-controller/local-disk* # commit-buffer
UCS-A /server/raid-controller/local-disk #
The example shows how to enable security on a JBOD for a blade server:
UCS-A# scope server 1/3
UCS-A chassis/server # scope raid-controller 3 sas
UCS-A chassis/server/raid-controller # scope local-disk 2
UCS-A chassis/server/raid-controller/local-disk # set admin-state enable-security
UCS-A chassis/server/raid-controller/local-disk* # commit-buffer
UCS-A chassis/server/raid-controller/local-disk #
Erasing a Secure Disk
Before you begin
Ensure that the disk is in the Unconfigured Good state.
SUMMARY STEPS
1.
UCS-A # scope server server-id
2.
UCS-A /server # scope raid-controller raid-controller-id {SAS | SAT}
3.
UCS-A /server/raid-controller # scope local-disk local-disk-id
4.
UCS-A /server/raid-controller/local-disk # set admin-state clear secure-drive
5.
UCS-A /server/raid-controller/local-disk* # commit-buffer
DETAILED STEPS
Step 1
Step 2
Command or Action
UCS-A # scope server server-id
Step 3
Step 4
Step 5
Purpose
Enters the server mode for the specified server.
UCS-A /server # scope raid-controller raid-controller-id
{SAS | SAT}
Enters the RAID controller mode.
Currently, Cisco UCS Manager supports SED only on SAS controllers.
UCS-A /server/raid-controller # scope local-disk local-disk-id
Enters the local disk configuration mode.
UCS-A /server/raid-controller/local-disk # set admin-state clear secure-drive
Erases the secured disk and clears the security on the disk.
UCS-A /server/raid-controller/local-disk* # commit-buffer Commits the transaction to the system configuration.
Example
This example shows how to erase a secure disk on a rack-mount server:
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
213
SED Security Policies
Disabling Security on a Controller
UCS-A # scope server 1
UCS-A /server # scope raid-controller 3 sas
UCS-A /server/raid-controller # scope local-disk 2
UCS-A /server/raid-controller/local-disk # set admin-state clear secure-drive
UCS-A /server/raid-controller/local-disk* # commit-buffer
UCS-A /server/raid-controller/local-disk #
This example shows how to erase a secure disk on a blade server:
UCS-A # scope server 1/3
UCS-A chassis/server # scope raid-controller 3 sas
UCS-A chassis/server/raid-controller # scope local-disk 2
UCS-A chassis/server/raid-controller/local-disk # set admin-state clear secure-drive
UCS-A chassis/server/raid-controller/local-disk* # commit-buffer
UCS-A chassis/server/raid-controller/local-disk #
Disabling Security on a Controller
Before you begin
You can disable security only on SAS controllers. To disable security on a controller, you must first disable security on all the secure disks and delete all the secure virtual drives under the controller.
SUMMARY STEPS
1.
UCS-A # scope server server-id
2.
UCS-A /server # scope raid-controller raid-controller-id {SAS | SAT}
3.
UCS-A /server/raid-controller # set admin-state disable-security
4.
UCS-A /server/raid-controller # commit-buffer
DETAILED STEPS
Step 1
Step 2
Command or Action
UCS-A # scope server server-id
Step 3
Step 4
Purpose
Enters the server mode for the specified server.
UCS-A /server # scope raid-controller raid-controller-id
{SAS | SAT}
Enters the RAID controller mode. Currently, Cisco UCS
Manager supports SED only on SAS controllers.
Disables security key on the controller.
UCS-A /server/raid-controller # set admin-state disable-security
UCS-A /server/raid-controller # commit-buffer Commits the transaction to the system configuration.
Example
This example shows how to disable security on the controller for a rack-mount server:
UCS-A# scope server 1
214
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
SED Security Policies
Unlocking a Locked Disk
UCS-A /server # scope raid-controller 3 sas
UCS-A /server/raid-controller # set admin-state disable-security
UCS-A /server/raid-controller* # commit-buffer
UCS-A /server/raid-controller #
This example shows how to disable security on the controller for a blade server:
UCS-A# scope server 1/3
UCS-A chassis/server # scope raid-controller 3 sas
UCS-A chassis/server/raid-controller # set admin-state disable-security
UCS-A chassis/server/raid-controller* # commit-buffer
UCS-A chassis/server/raid-controller #
Unlocking a Locked Disk
When the key of an SED does not match the key on the controller, it shows the disk as Locked, Foreign Secure.
You must unlock the disks either by providing the security-key for that disk, or by using the remote KMIP server. After unlocking the disk, import or clear the foreign configuration.
After you unlock a locked disk, the security status of the disk will show as Foreign Secure.
SUMMARY STEPS
1.
UCS-A # scope server server-id
2.
UCS-A /server # scope raid-controller raid-controller-id {SAS | SAT}
3.
UCS-A /server/raid-controller # set admin-state unlock-disk [ security-key ]
4.
UCS-A /server/raid-controller* # commit-buffer
DETAILED STEPS
Step 1
Step 2
Step 3
Step 4
Command or Action
UCS-A # scope server server-id
Purpose
Enters server mode for the specified server.
UCS-A /server # scope raid-controller raid-controller-id
{SAS | SAT}
Enters the RAID controller mode. Currently, Cisco UCS
Manager supports SEDs only on SAS controllers.
UCS-A /server/raid-controller # set admin-state unlock-disk [ security-key ]
Unlocks the locked disks.
If the security-key is set, this key is used to unlock disks that are in the locked state.
If the security-key is not set, Cisco UCS Manager tries to unlock the disks by using the KMIP server. Setting the security-key is optional only if remote security is configured on the server.
UCS-A /server/raid-controller* # commit-buffer Commits the transaction to the system configuration.
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
215
SED Security Policies
Erasing a Secure Foreign Configuration Disk
Example
This example shows how to unlock a locked disk on a rack-mount server with a local security policy by using a security-key:
UCS-A # scope server 1
UCS-A /server # scope raid-controller 3 sas
UCS-A /server/raid-controller # set admin-state unlock-disk thisisastring
UCS-A /server/raid-controller* # commit-buffer
UCS-A /server/raid-controller #
This example shows how to unlock a locked disk on a rack-mount server with a remote security policy by using the KMIP server:
UCS-A # scope server 1
UCS-A /server # scope raid-controller 3 sas
UCS-A /server/raid-controller # set admin-state unlock-disk
UCS-A /server/raid-controller* # commit-buffer
UCS-A /server/raid-controller #
This example shows how to unlock a locked disk on a blade server with a local security policy by using a security-key:
UCS-A # scope server 1/2
UCS-A chassis/server # scope raid-controller 3 sas
UCS-A chassis/server/raid-controller # set admin-state unlock-disk thisisastring
UCS-A chassis/server/raid-controller* # commit-buffer
UCS-A chassis/server/raid-controller #
This example shows how to unlock a locked disk on a blade server with a remote security policy by using the KMIP server:
UCS-A # scope server 1/2
UCS-A chassis/server # scope raid-controller 3 sas
UCS-A chassis/server/raid-controller # set admin-state unlock-disk
UCS-A chassis/server/raid-controller* # commit-buffer
UCS-A chassis/server/raid-controller #
Erasing a Secure Foreign Configuration Disk
You can erase a secure foreign configuration disk when you have a disk in locked state and you want to use the disk without accessing the existing data.
SUMMARY STEPS
1.
UCS-A # scope server server-id
2.
UCS-A /server # scope raid-controller raid-controller-id {SAS | SAT}
3.
UCS-A /server/raid-controller # scope local-disk local-disk-id
4.
UCS-A /server/raid-controller/local-disk # set admin-state clear secure-foreign-config-drive
5.
UCS-A /server/raid-controller/local-disk* # commit-buffer
216
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
SED Security Policies
Displaying the Security Flags of a Controller
DETAILED STEPS
Step 1
Step 2
Step 3
Step 4
Step 5
Command or Action
UCS-A # scope server server-id
Purpose
Enters the server mode for the specified server.
UCS-A /server # scope raid-controller raid-controller-id
{SAS | SAT}
Enters the RAID controller mode.
Currently, Cisco UCS Manager supports SED only on SAS controllers.
UCS-A /server/raid-controller # scope local-disk local-disk-id
Enters the local disk configuration mode.
UCS-A /server/raid-controller/local-disk # set admin-state clear secure-foreign-config-drive
Clears the secure foreign configuration drive.
UCS-A /server/raid-controller/local-disk* # commit-buffer Commits the transaction to the system configuration.
Example
This example shows how to clear a foreign configuration disk on a rack-mount server:
UCS-A# scope server 1
UCS-A /server # scope raid-controller 3 sas
UCS-A /server/raid-controller # scope local-disk 2
UCS-A /server/raid-controller/local-disk # set admin-state clear secure-foreign-config-drive
UCS-A /server/raid-controller/local-disk* # commit-buffer
UCS-A /server/raid-controller/local-disk #
This example shows how to clear a foreign configuration disk on a blade server:
UCS-A# scope server 1/3
UCS-A chassis/server # scope raid-controller 3 sas
UCS-A chassis/server/raid-controller # scope local-disk 2
UCS-A chassis/server/raid-controller/local-disk # set admin-state clear secure-foreign-config-drive
UCS-A chassis/server/raid-controller/local-disk* # commit-buffer
UCS-A chassis/server/raid-controller/local-disk #
Displaying the Security Flags of a Controller
SUMMARY STEPS
1.
UCS-A # scope server server-id
2.
UCS-A /server # scope raid-controller raid-controller-id {SAS | SAT}
3.
UCS-A /server/raid-controller # show detail
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
217
SED Security Policies
Displaying the Security Flags of a Controller
DETAILED STEPS
Step 1
Step 2
Command or Action
UCS-A # scope server server-id
Step 3
Purpose
Enters the server mode for the specified server.
UCS-A /server # scope raid-controller raid-controller-id
{SAS | SAT}
Enters the RAID controller mode.
Currently, Cisco UCS Manager supports SED only on SAS controllers.
UCS-A /server/raid-controller # show detail Displays details of the RAID controller.
Example
This example shows to how to check if the security flag of controller is enabled on a rack-mount server:
UCS-A # scope server 1
UCS-A /server # scope raid-controller 3 sas
UCS-A /server/raid-controller # show detail
RAID Controller:
ID: 3
Type: SAS
PCI Addr: 03:00.0
Vendor: LSI Corp.
Model: LSI MegaRAID SAS 3108
Serial: SV55346948
HW Rev: C0
Raid Support: RAID0, RAID1, RAID5, RAID6, RAID10, RAID50, RAID60
OOB Interface Supported: Yes
Mode: RAID
Rebuild Rate: 30
Controller Status: Optimal
Config State: Applied
Pinned Cache Status: Disabled
Sub OEM ID: 0
Supported Strip Sizes: 1MB,64KB,256KB,512KB,128KB
Default Strip Size: 64KB
PCI Slot: HBA
Controller Flags: Drive Security Capable
This example shows to how to check if the security flag of controller is enabled on a blade server:
UCS-A # scope server 1/2
UCS-A chassis/server # scope raid-controller 3 sas
UCS-A chassis/server/raid-controller # show detail
RAID Controller:
ID: 3
Type: SAS
PCI Addr: 03:00.0
Vendor: LSI Corp.
Model: LSI MegaRAID SAS 3108
Serial: SV55346948
218
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
SED Security Policies
Displaying the Security Flags of a Local Disk
HW Rev: C0
Raid Support: RAID0, RAID1, RAID5, RAID6, RAID10, RAID50, RAID60
OOB Interface Supported: Yes
Mode: RAID
Rebuild Rate: 30
Controller Status: Optimal
Config State: Applied
Pinned Cache Status: Disabled
Sub OEM ID: 0
Supported Strip Sizes: 1MB,64KB,256KB,512KB,128KB
Default Strip Size: 64KB
PCI Slot: HBA
Controller Flags: Drive Security Capable
Displaying the Security Flags of a Local Disk
SUMMARY STEPS
1.
UCS-A # scope server server-id
2.
UCS-A /server # scope raid-controller raid-controller-id {SAS | SAT}
3.
UCS-A /server/raid-controller # scope local-disk local-disk-id
4.
UCS-A /server/raid-controller/local-disk # show detail
DETAILED STEPS
Step 1
Step 2
Command or Action
UCS-A # scope server server-id
Purpose
Enters the server mode for the specified server.
UCS-A /server # scope raid-controller raid-controller-id
{SAS | SAT}
Enters the RAID controller mode.
Currently, Cisco UCS Manager supports SED only on SAS controllers.
Step 3 Enters the local disk configuration mode.
Step 4
UCS-A /server/raid-controller # scope local-disk local-disk-id
UCS-A /server/raid-controller/local-disk # show detail Displays details of the local disk.
Example
This example shows to how to display the security flag of a local disk on a rack-mount server:
UCS-A # scope server 1
UCS-A /server # scope raid-controller 3 sas
UCS-A /server/raid-controller # scope local-disk 2
UCS-A /server/raid-controller/local-disk # show detail
Local Disk:
ID: 4
Block Size: 512
Physical Block Size: 4096
Blocks: 1560545280
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
219
SED Security Policies
Displaying the Security Flags of a Local Disk
Raw Size: 763097
Size: 761985
Technology: SSD
Operability: Operable
Oper Qualifier Reason: N/A
Presence: Equipped
Connection Protocol: SAS
Product Variant: default
Product Name: 800GB Enterprise performance SAS SED SSD (10 FWPD) - MTFDJAK800MBS
PID: UCS-SD800GBEK9
VID: V01
Vendor: MICRON
Model: S650DC-800FIPS
Vendor Description: Micron
Serial: ZAZ090VD0000822150Z3
HW Rev: 0
Running-Vers: MB13
Average Seek Time (R/W): N/A
Track to Track Seek Time (R/W): 115ms
Part Number: 16-100911-01
SKU: UCS-SD800GBEK9
Drive State: Online
Power State: Active
Link Speed: 12 Gbps
Enclosure Association Type: Direct Attached
Device Version: MB13
Drive Security Flags: Secured,Security Enabled,Security Capable
This example shows to how to display the security flag of a local disk on a blade server:
UCS-A # scope server 1/2
UCS-A chassis/server # scope raid-controller 3 sas
UCS-A chassis/server/raid-controller # scope local-disk 2
UCS-A chassis/server/raid-controller/local-disk # show detail
Local Disk:
ID: 4
Block Size: 512
Physical Block Size: 4096
Blocks: 1560545280
Raw Size: 763097
Size: 761985
Technology: SSD
Operability: Operable
Oper Qualifier Reason: N/A
Presence: Equipped
Connection Protocol: SAS
Product Variant: default
Product Name: 800GB Enterprise performance SAS SED SSD (10 FWPD) - MTFDJAK800MBS
PID: UCS-SD800GBEK9
VID: V01
Vendor: MICRON
Model: S650DC-800FIPS
Vendor Description: Micron
Serial: ZAZ090VD0000822150Z3
HW Rev: 0
Running-Vers: MB13
Average Seek Time (R/W): N/A
Track to Track Seek Time (R/W): 115ms
Part Number: 16-100911-01
SKU: UCS-SD800GBEK9
220
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
SED Security Policies
Displaying the Security Flags of a Virtual Drive
Drive State: Online
Power State: Active
Link Speed: 12 Gbps
Enclosure Association Type: Direct Attached
Device Version: MB13
Drive Security Flags: Secured,Security Enabled,Security Capable
Displaying the Security Flags of a Virtual Drive
SUMMARY STEPS
1.
UCS-A # scope server server-id
2.
UCS-A /server # scope raid-controller raid-controller-id {SAS | SAT}
3.
UCS-A /server/raid-controller # scope virtual-drive virtual-drive-id
4.
UCS-A /server/raid-controller/virtual-drive # show detail
DETAILED STEPS
Step 1
Step 2
Command or Action
UCS-A # scope server server-id
Purpose
Enters the server mode for the specified server.
UCS-A /server # scope raid-controller raid-controller-id
{SAS | SAT}
Enters the RAID controller mode.
Currently, Cisco UCS Manager supports SED only on SAS controllers.
Step 3
Step 4
UCS-A /server/raid-controller # scope virtual-drive virtual-drive-id
Enters the virtual drive mode.
UCS-A /server/raid-controller/virtual-drive # show detail Displays details of the virtual drive.
Example
This example shows to how to display the security flag of a virtual disk for a rack-mount server:
UCS-A # scope server 1
UCS-A /server # scope raid-controller 3 sas
UCS-A /server/raid-controller # scope virtual-drive 1000
UCS-A /server/raid-controller/virtual-drive # show detail
Virtual Drive:
ID: 1000
Name: luna
Block Size: 512
Blocks: 20971520
Size: 10240
Operability: Operable
Presence: Equipped
Lifecycle: Allocated
Drive State: Optimal
Type: RAID 0 Striped
Strip Size (KB): 64
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
221
SED Security Policies
Displaying the Security Flags of a Virtual Drive
Access Policy: Read Write
Read Policy: Normal
Configured Write Cache Policy: Write Through
Actual Write Cache Policy: Write Through
IO Policy: Direct
Drive Cache: No Change
Bootable: False
Oper Device ID: 0
Change Qualifier: No Change
Config State: Applied
Deploy Action: No Action
Service Profile Lun Reference: org-root/ls-sp1/vdrive-ref-lun-1
Assigned To Server: sys/rack-unit-1
Available Size on Disk Group (MB): 751745
Unique Identifier: 90ae6ea0-6a39-49e1-9c0d-0f3e2e9ecfce
Vendor Unique Identifier: 678da6e7-15b2-9c20-2011-c4f60c40e57a
Security Flags: Drive Security Enable,Drive Security Capable
This example shows to how to display the security flag of a virtual disk for a blade server:
UCS-A # scope server 1/2
UCS-A chassis/server # scope raid-controller 3 sas
UCS-A chassis/server/raid-controller # scope virtual-drive 1000
UCS-A chassis/server/raid-controller/virtual-drive # show detail
Virtual Drive:
ID: 1000
Name: luna
Block Size: 512
Blocks: 20971520
Size: 10240
Operability: Operable
Presence: Equipped
Lifecycle: Allocated
Drive State: Optimal
Type: RAID 0 Striped
Strip Size (KB): 64
Access Policy: Read Write
Read Policy: Normal
Configured Write Cache Policy: Write Through
Actual Write Cache Policy: Write Through
IO Policy: Direct
Drive Cache: No Change
Bootable: False
Oper Device ID: 0
Change Qualifier: No Change
Config State: Applied
Deploy Action: No Action
Service Profile Lun Reference: org-root/ls-sp1/vdrive-ref-lun-1
Assigned To Server: sys/rack-unit-1
Available Size on Disk Group (MB): 751745
Unique Identifier: 90ae6ea0-6a39-49e1-9c0d-0f3e2e9ecfce
Vendor Unique Identifier: 678da6e7-15b2-9c20-2011-c4f60c40e57a
Security Flags: Drive Security Enable,Drive Security Capable
222
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
C H A P T E R
14
Storage Inventory
•
NVMe-optimized M5 Servers, on page 223
•
Volume Management Device (VMD) Setup, on page 225
NVMe-optimized M5 Servers
Beginning with 3.2(3a), Cisco UCS Manager supports the following NVMe-optimized M5 servers:
• UCSC-C220-M5SN—The PCIe MSwitch is placed in the dedicated MRAID slot for UCS C220 M5 servers. This setup supports up to 10 NVMe drives. The first two drives are direct-attached through the riser. The remaining eight drives are connected and managed by the MSwitch. This setup does not support any SAS/SATA drive combinations.
• UCSC-C240-M5SN—The PCIe MSwitch is placed in the riser-2 at slot-4 for UCS C240 M5 servers.
The servers support up to 24 drives. Slots 1-8 are the NVMe drives connected and managed by the
MSwitch. The servers also support up to two NVMe drives in the rear and are direct-attached through the riser. This setup supports SAS/SATA combination with the SAS/SATA drives from slots 9-24. These drives are managed by the SAS controller placed in the dedicated MRAID PCIe slot.
• UCS-C480-M5—UCS C480 M5 servers support up to three front NVMe drive cages, each supporting up to eight NVMe drives. Each cage has an interposer card, which contains the MSwitch. Each server can support up to 24 NVMe drives (3 NVMe drive cages x 8 NVMe drives). The servers also support a rear PCIe Aux drive cage, which can contain up to eight NVMe drives managed by an MSwitch placed in PCIe slot-10.
This setup does not support:
• a combination of NVMe drive cages and HDD drive cages
• a combination of the Cisco 12G 9460-8i RAID controller and NVMe drive cages, irrespective of the rear Auxiliary drive cage
Note The UCS C480 M5 PID remains same as in earlier release.
The following MSwitch cards are supported in NVMe optimized M5 servers:
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
223
Storage Inventory
MSwitch Disaster Recovery
• UCS-C480-M5 HDD Ext NVMe Card (UCSC-C480-8NVME)—Front NVMe drive cage with an attached interposer card containing the PCIe MSwitch. Each server supports up to three front NVMe drive cages and each cage supports up to 8 NVMe drives. Each server can support up to 24 NVMe drives (3 NVMe drive cages x 8 NVMe drives).
• UCS-C480-M5 PCIe NVMe Switch Card (UCSC-NVME-SC)—PCIe MSwitch card to support up to eight NVMe drives in the rear auxiliary drive cage inserted in PCIe slot 10.
Note Cisco UCS-C480-M5 servers support a maximum of 32 NVMe drives (24 NVMe drives in the front + 8 NVMe drives in the rear auxiliary drive cage)
• UCSC-C220-M5SN and UCSC-C240-M5SN do not have separate MSwitch PIDs. MSwitch cards for these servers are part of the corresponding NVMe optimized server.
MSwitch Disaster Recovery
You can recover a corrupted MSwitch and roll back to a previous working firmware.
Note If you have a setup with Cisco UCS C480 M5 Server, then MSwitch disaster recovery process can be performed only on one MSwitch at a time. If the disaster recovery process is already running for one MSwitch, then wait for it to complete. You can monitor the recovery status from FSM.
SUMMARY STEPS
1.
UCS-A# scope server [ chassis-num / server-num | dynamic-uuid ]
2.
UCS-A /server # scope nvme-swtich nvme_switch
3.
UCS-A /server/nvme-switch # set recover-nvme-switch
4.
UCS-A /server/nvme-switch* # commit-buffer
5.
UCS-A /server/nvme-switch # exit
6.
UCS-A /server # ack-nvme-switch-recovery acknowledge
7.
UCS-A /server* # commit-buffer
DETAILED STEPS
Step 1
Step 2
Step 3
Command or Action
UCS-A# scope server [ chassis-num / server-num | dynamic-uuid ]
UCS-A /server # scope nvme-swtich nvme_switch
Step 4
UCS-A /server/nvme-switch # set recover-nvme-switch
UCS-A /server/nvme-switch* # commit-buffer
Step 5 UCS-A /server/nvme-switch # exit
Purpose
Enters server mode for the specified server.
Enters the specified NVMe swtich.
Deletes the LUN Set with the specified name.
Commits the transaction to the system configuration.
Exits the MSwitch mode.
224
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
Storage Inventory
Volume Management Device (VMD) Setup
Step 6
Step 7
Command or Action Purpose
UCS-A /server # ack-nvme-switch-recovery acknowledge Acknowledges the MSwitch recovery.
UCS-A /server* # commit-buffer Commits the transaction to the system configuration.
Note Do not reset the server during the disaster recovery process.
Example
The following example recovers the MSwitch on server1:
UCS-A# scope server 1
UCS-A/server # scope nvme-switch 1
UCS-A/server/nvme-switch # set recover-nvme-switch
UCS-A/server/nvme-switch* # commit-buffer
UCS-A/server/nvme-switch # exit
UCS-A/server # ack-nvme-switch-recovery acknowledge
UCS-A/server* # commit-buffer
Volume Management Device (VMD) Setup
The Intel ® Volume Management Device (VMD) is a tool that provides NVMe drivers to manage PCIe Solid
State Drives attached to VMD-enabled domains. This includes Surprise hot-plug of PCIe drives and configuring blinking patterns to report status. PCIe Solid State Drive (SSD) storage lacks a standardized method to blink
LEDs to represent the status of the device. With VMD, you can control LED indicators on both direct attached and switch attached PCIe storage using a simple command-line tool.
To use VMD, you must first enable VMD through a UCS Manager BIOS policy and set the UEFI boot options.
Enabling VMD provides Surprise hot plug and optional LED status management for PCIe SSD storage that is attached to the root port. VMD Passthrough mode provides the ability to manage drives on guest VMs.
Enabling VMD also allows configuration of Intel ® on Intel ® Xeon ®
Virtual RAID on CPU (VRoC), a hybrid RAID architecture
Scalable Processors. Documentation on the use and configuration of VRoC can be found at the Intel website.
IMPORTANT : VMD must be enabled in the UCS Manager BIOS settings before Operating System install.
If enabled after OS installation, the server will fail to boot. This restriction applies to both standard VMD and
VMD Passthrough. Likewise, once enabled, you cannot disable VMD without a loss of system function.
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
225
Volume Management Device (VMD) Setup
Storage Inventory
226
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
C H A P T E R
15
Cisco UCS S3260 System Storage Management
•
Storage Server Features and Components Overview, on page 227
•
Cisco UCS S3260 Storage Management Operations, on page 235
•
Disk Sharing for High Availability, on page 236
•
Storage Enclosure Operations, on page 240
•
SAS Expander Configuration Policy, on page 241
Storage Server Features and Components Overview
Storage Server Features
The following table summarizes the Cisco UCS S3260 system features:
Table 4: Cisco UCS S3260 System Features
Feature
Chassis
Processors
Description
Four rack unit (4RU) chassis
• Cisco UCS S3260 M3 server nodes: Two Intel
Xeon E5-2600 v2 Series processors inside each server node.
• Cisco UCS S3260 M4 server nodes: Two Intel
Xeon E5-2600 v4 Series processors inside each server node.
• Cisco UCS S3260 M5 server nodes: Two Intel
Skylake 2S-EP processors inside each server node.
Memory
Multi-bit error protection
Up to 16 DIMMs inside each server node.
This system supports multi-bit error protection.
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
227
Storage Server Features and Components Overview
Feature
Storage
Disk Management
RAID Backup
PCIe I/O
Cisco UCS S3260 System Storage Management
Description
The system has the following storage options:
• Up to 56 top-loading 3.5-inch drives
• Up to four 3.5-inch, rear-loading drives in the optional drive expander module
• Up to four 2.5-inch, rear-loading SAS solid state drives (SSDs)
• One 2.5-inch, NVMe drive inside the server node
Note This is applicable for S3260 M4 servers only.
• Two 7 mm NVMe drive inside the server node
Note This is applicable for S3260 M5 servers only.
• Two 15 mm NVMe drive supported for IO
Expander
The system supports up to two storage controllers:
• One dedicated mezzanine-style socket for a Cisco storage controller card inside each server node
The supercap power module (SCPM) mounts to the
RAID controller card.
The optional I/O expander provides two 8x Gen 3
PCIe expansion slots.
Release 3.2(3) and later supports the following for
S3260 M5 servers:
• Intel X550 dual-port 10GBase-T
• Qlogic QLE2692 dual-port 16G Fiber Channel
HBA
• N2XX-AIPCI01 Intel X520 Dual Port 10Gb
SFP+ Adapter
228
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
Cisco UCS S3260 System Storage Management
Storage Server Features and Components Overview
Feature
Network and Management I/O
Power
Cooling
Description
The system can have one or two system I/O controllers
(SIOCs). These provide rear-panel management and data connectivity.
• Two SFP+ 40 Gb ports each SIOC.
• One 10/100/1000 Ethernet dedicated management port on each SIOC.
The server nodes each have one rear-panel KVM connector that can be used with a KVM cable, which provides two USB, one VGA DB-15, and one serial
DB-9 connector.
Two or four power supplies, 1050 W each
(hot-swappable and redundant as 2+2).
Four internal fan modules that pull front-to-rear cooling, hot-swappable. Each fan module contains two fans.
In addition, there is one fan in each power supply.
Front Panel Features
The following image shows the front panel features for the Cisco UCS S3260 system:
Figure 4: Front Panel Features
1
2
3
Operations panel
System Power button/LED
System unit identification button/LED
6
7
8
Temperature status LED
Power supply status LED
Network link activity LED
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
229
Cisco UCS S3260 System Storage Management
Storage Server Features and Components Overview
4
5
System status LED
Fan status LED
9
10
Pull-out asset tag (not visible under front bezel)
Internal-drive status LEDs
Rear Panel Features
The following image shows the rear panel features for the Cisco UCS S3260 system:
Figure 5: Front Panel Features
Disk Slots
1 Server bay 1
• (Optional) I/O expander, as shown (with
Cisco UCS
S3260 M4 and
M5 server node only)
8
• (Optional) server node
• (Optional) drive expansion module
Not used at this time
230
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
Cisco UCS S3260 System Storage Management
2
3
4
Server bay 2
• (Optional) server node
(Cisco UCS
S3260 M4 and
M5 shown)
9
(Optional) drive expansion module
System I/O controller (SIOC)
• SIOC 1 is required if you have a server node in server bay 1
10
• SIOC 2 is required if you have server node in server bay 2
Power supplies
(four, redundant as
2+2)
11
Storage Server Features and Components Overview
Not used at this time
5
6
40-Gb SFP+ ports
(two on each SIOC)
Chassis
Management
Controller (CMS)
Debug Firmware
Utility port (one each SIOC)
12
13
Solid state drive bays (up to four 2.5-inch SAS SSDs)
• SSDs in bays 1 and 2 require a server node in server bay 1
• SSDs in bays 3 and 4 require a server node in server bay 2
Cisco UCS S3260 M4 server node label (M4 SVRN)
Note This label identifies a Cisco UCS S3260
M4 and M5 server node. The Cisco
UCS S3260 M3 server node does not have a label.
KVM console connector (one each server node).
Used with a KVM cable that provides two USB, one VGA, and one serial connector
Server node unit identification button/LED
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
231
Cisco UCS S3260 System Storage Management
Storage Server Features and Components Overview
7 10/100/1000 dedicated management port,
RJ-45 connector
(one each SIOC)
14
15
Server node power button
Server node reset button (resets chipset in the server node
Storage Server Components
Server Nodes
The Cisco UCS S3260 system consists of one or two server nodes, each with two CPUs, DIMM memory of
128, 256, or 512 GB, and a RAID card up to 4 GB cache or a pass-through controller. The server nodes can be one of the following:
• Cisco UCS S3260 M3 Server Node
• Cisco UCS S3260 M4 Server Node—This node might include an optional I/O expander module that attaches to the top of the server node.
• Cisco UCS S3260 M5 Server Node—This node might include an optional I/O expander module that attaches to the top of the server node.
Disk Slots
The Cisco UCS S3260 chassis has 4 rows of 14 disk slots on the HDD motherboard and 4 additional disk slots on the HDD expansion tray. The following image shows the disk arrangement for the 56 top-accessible, hot swappable 3.5-inch 6 TB or 4 TB 7200 rpm NL-SAS HDD drives. A disk slot has two SAS ports and each is connected a SAS expander in the chassis.
Figure 6: Cisco UCS S3260 Top View
The following image shows the Cisco UCS S3260 chassis with the 4 additional disk slots on the HDD expansion tray.
232
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
Cisco UCS S3260 System Storage Management
Figure 7: Cisco UCS 3260 with the HDD expansion tray (Rear View)
Storage Server Features and Components Overview
If you have two server nodes with two SIOCs, you will have the following functionality:
1.
The top server node works with the left SIOC (Server Slot1 with SIOC1).
2.
The bottom server works with the right SIOC (Sever Slot 2 with SIOC2).
If you have one server node with two SIOCs, you can enable Server SIOC Connectivity functionality. Beginning with release 3.1(3), Cisco UCS S3260 system supports Server SIOC Connectivity functionality. Using this functionality, you can configure the data path through both the primary and auxiliary SIOCs when the chassis has single server and dual SIOCs set up.
SAS Expanders
The Cisco UCS S3260 system has two SAS expanders that run in redundant mode and connect the disks at the chassis level to storage controllers on the servers. The SAS expanders provide two paths between a storage controller, and hence enable high availability. They provide the following functionality:
• Manage the pool of hard drives.
• Disk zone configuration of the hard drives to storage controllers on the servers.
Beginning with release 3.2(3a), Cisco UCS Manager can enable single path access to disk by configuring single DiskPort per disk slot. This ensures that the server discovers only a single device and avoid a multi-path configuration.
The following table describes how the ports in each SAS expander are connected to the disks based on the type of deployment.
Port range Connectivity
1-56
57-60
Top accessible disks
Disks in the HDD expansion tray.
Note The number of SAS uplinks between storage controller and SAS expander can vary based on the type of controller equipped in the server.
Storage Enclosures
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
233
Cisco UCS S3260 System Storage Management
Storage Server Features and Components Overview
A Cisco UCS S3260 system has the following types of storage enclosures:
Chassis Level Storage Enclosures
• HDD motherboard enclosure —The 56 dual port disk slots in the chassis comprise the HDD motherboard enclosure.
• HDD expansion tray —The 4 additional dual disk slots in the Cisco UCS S3260 system comprise the HDD expansion tray.
Note The HDD expansion tray is a field replaceable unit (FRU). The disks will remain unassigned upon insertion, and can be assigned to storage controllers. For detailed steps on how to perform disk zoning, see
Disk Zoning Policies, on page 236
Server level Storage Enclosures
Server level storage enclosures are pre-assigned dedicated enclosures to the server. These can be one of the following:
• Rear Boot SSD enclosure —This enclosure contains two 2.5 inch disk slots on the rear panel of the Cisco UCS S3260 system. Each server has two dedicated disk slots. These disk slots support
SATA SSDs.
• Server board NVMe enclosure —This enclosure contains one PCIe NVMe controller.
Note In the Cisco UCS S3260 system, even though disks can be physically present on the two types of enclosures described above, from the host OS all the disks are viewed as part of one SCSI enclosure.
They are connected to SAS expanders that are configured to run as single SES enclosure.
Storage Controllers
Mezzanine Storage Controllers
The following table lists the storage controller type, firmware type, modes, sharing and OOB support for the various storage controllers.
Table 5:
Modes Sharing OOB Support Storage Controller
Type
Firmware type
UCSC-S3X60-R1GB Mega RAID
UCS-C3K-M4RAID Mega RAID
UCSC-S3X60-HBA Initiator Target
UCS-S3260-DHBA Initiator Target
UCS-S3260-DRAID Mega RAID
HW RAID, JBOD
HW RAID, JBOD
Pass through
Pass through
No
No
Yes
Yes
HW RAID, JBOD No
Yes
Yes
Yes
Yes
Yes
234
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
Cisco UCS S3260 System Storage Management
Cisco UCS S3260 Storage Management Operations
Other storage controllers
SW RAID Controller —The servers in the Cisco UCS S3260 system support two dedicated internal
SSDs embedded into the PCIe riser that is connected to the SW RAID Controller. This controller is supported on the Cisco C3000 M3 servers.
NVMe Controller —This controller is used by servers in the Cisco UCS S3260 system for inventory and firmware updates of NVMe disks.
For more details about the storage controllers supported in the various server nodes, see the related service note:
• Cisco UCS C3X60 M3 Server Node For Cisco UCS S3260 Storage Server Service Note
• Cisco UCS C3X60 M4 Server Node For Cisco UCS S3260 Storage Server Service Note
• Cisco UCS S3260 M5 Server Node For Cisco UCS S3260 Storage Server Service Note
Cisco UCS S3260 Storage Management Operations
The following table summarizes the various storage management operations that you can perform with the
Cisco UCS Manager integrated Cisco UCS S3260 system.
Operation
Disk Sharing for High
Availability
Description See:
The SAS expanders in the
Cisco UCS S3260 system can manage the pool of drives at the chassis level. To share disks for high availability, perform the following:
"Disk Zoning Policies" section in this guide.
1.
Creating disk zoning policies.
2.
Creating disk slots and assigning ownership.
3.
Associating disks to chassis profile.
Storage Profiles, Disk Groups and Disk Group Configuration
Policies
You can utilize Cisco UCS
Manager's Storage Profile and
Disk Group Policies for defining storage disks, disk allocation and management in the Cisco UCS S3260 system.
"Storage Profiles" section in the Cisco UCS
Manager Storage Management Guide, Release
3.2.
Storage Enclosure Operations You can swap the HDD expansion tray with a server, or remove the tray if it was previously inserted.
"Removing Chassis Level Storage Enclosures" section in this guide.
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
235
Cisco UCS S3260 System Storage Management
Disk Sharing for High Availability
Disk Sharing for High Availability
Disk Zoning Policies
You can assign disk drives to the server nodes using disk zoning. Disk zoning can be performed on the controllers in the same server or on the controllers on different servers. Disk ownership can be one of the following:
Unassigned
Unassigned disks are those not visible to the server nodes.
Dedicated
If this option is selected, you will need to set the values for the Server , Controller , Drive Path , and
Slot Range for the disk slot.
Note A disk is visible only to the assigned controller.
Beginning with release 3.2(3a), Cisco UCS Manager can enable single path access to disk by configuring single DiskPort per disk slot for Cisco UCS S3260 M5 and higher servers. Setting single path configuration ensures that the server discovers the disk drive only through a single drive path chosen in the configuration.
Single path access is supported only for Cisco UCS S3260 Dual Pass Through Controller
(UCS-S3260-DHBA)
Once single path access is enabled, you cannot downgrade to any release earlier than 3.2(3a). To downgrade, disable this feature and assign all the disk slots to both the disk ports by configuring disk path of the disk slots to Path Both in disk zoning policy.
Shared
Shared disks are those assigned to more than one controller. They are specifically used when the servers are running in a cluster configuration, and each server has its storage controllers in HBA mode.
Note Shared mode cannot be used under certain conditions when dual HBA controllers are used.
Chassis Global Hot Spare
If this option is selected, you will need to set the value for the Slot Range for the disk.
Important Disk migration and claiming orphan LUNs: To migrate a disk zoned to a server (Server 1) to another server
(Server 2), you must mark the virtual drive (LUN) as transport ready or perform a hide virtual drive operation.
You can then change the disk zoning policy assigned for that disk. For more information on virtual drive management, see the Disk Groups and Disk Configuration Policies section of the Cisco UCS Manager Storage
Management Guide .
236
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
Cisco UCS S3260 System Storage Management
Creating a Disk Zoning Policy
Creating a Disk Zoning Policy
Step 1
Procedure
Command or Action
UCS-A# scope org org-name
Step 2
Step 3
UCS-A org/ # create disk-zoning-policy diskzoning policy-name
UCS-A /org/disk-zoning-policy* # commit-buffer
Purpose
Enters organization mode for the specified organization.
To enter the root organization mode, type / as the org-name .
Creates a disk zoning policy name with the specified disk zoning policy name.
Commits the transaction to the system configuration.
Example
The following example creates the dzp1 disk zoning policy:
UCS-A# scope org
UCS-A /org # create disk-zoning-policy dzp1
UCS-A /org/disk-zoning-policy*# commit-buffer
UCS-A /org/disk-zoning-policy#
Creating Disk Slots and Assigning Ownership
Step 1
Step 2
Step 3
Step 4
Command or Action
UCS-A#
Procedure
scope org org-name
Purpose
Enters organization mode for the specified organization.
To enter the root organization mode, type / as the org-name .
UCS-A org/ # disk-zoning-policy disk-zoning-policy-name Enters the disk zoning policy.
UCS-A org/disk-zoning-policy # create disk-slot slot-id Creates disk slot with the specified slot number.
UCS-A org/disk-zoning-policy/disk-slot* # set ownership ownership-type
{chassis-global-host-spare\dedicated\shared\unassigned}
Specifies the disk ownership to be one of the following:
• chassis-global-hot-spare —Chassis Global Hot Spare
• dedicated —Dedicated
Beginning with release 3.2(3a), Cisco UCS Manager can enable single path access to disk by configuring single DiskPort per disk slot. This ensures that the server discovers only a single device and avoid a multi-path configuration.
Drive Path options are:
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
237
Cisco UCS S3260 System Storage Management
Creating Disk Slots and Assigning Ownership
Step 5
Step 6
Command or Action Purpose
• path-both (Default) - Drive path is zoned to both the SAS expanders.
• path-0 - Drive path is zoned to SAS expander 1.
• path-1 - Drive path is zoned to SAS expander 2.
Use the following command to set the drivepath: set drivepath drivepath{path-0/path-1/path-both}
• shared —Shared
Note Shared mode cannot be used under certain conditions when dual HBA controllers are used. To view the conditions for Shared mode for Dual HBA controller, see
6: Limitations for Shared Mode for Dual
• unassigned —Unassigned
UCS-A org/disk-zoning-policy/disk-slot* # create
controller-ref server-id sas controller-id
Creates controller reference for the specified server slot.
UCS-A org/disk-zoning-policy/disk-slot # commit-buffer Commits the transaction.
Table 6: Limitations for Shared Mode for Dual HBA Controller
Server
Cisco UCS S3260
Cisco UCS S3260
Pre-Provisioned
HDD Tray
No
HDD Tray
HDD Tray
Controller
Dual HBA
Dual HBA
Dual HBA
Shared mode Support
Not Supported
Not Supported
Not Supported
Example
The following example creates disk slot 1, sets the ownership as shared, creates a controller reference for the server slot 1, and commits the transaction:
UCS-A# scope org
UCS-A /org # scope disk-zoning-policy test
UCS-A /org/disk-zoning-policy* # create disk-slot 1
UCS-A /org/disk-zoning-policy/disk-slot* # set ownership shared
UCS-A /org/disk-zoning-policy/disk-slot* # create controller-ref 1 sas 1
UCS-A /org/disk-zoning-policy/disk-slot* # create controller-ref 2 sas 1
UCS-A /org/disk-zoning-policy/disk-slot* # commit-buffer
UCS-A /org/disk-zoning-policy/disk-slot #
238
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
Cisco UCS S3260 System Storage Management
Associating Disk Zoning Policies to Chassis Profile
Associating Disk Zoning Policies to Chassis Profile
Step 1
Step 2
Step 3
Step 4
Step 5
Command or Action
UCS-A#
Procedure scope org org-name
Purpose
Enters organization mode for the specified organization.
To enter the root organization mode, type / as the org-name .
UCS-A org/ # create chassis-profile chassis-profile-name Creates a chassis profile with the specified name.
UCS-A org/chassis-profile* # set disk-zoning-policy disk-zoning-policy
UCS-A org/chassis-profile* # commit-buffer
Sets the specified disk-zoning-policy.
Commits the transaction.
UCS-A org/chassis-profile # associate chassis chassis-id Associates the disks in the disk zoning policy to the chassis with the specified chassis number.
Example
The following example creates the ch1 chassis profile, sets the disk zoning policy all56shared, commits the transaction and associates the disk in the all56shared policy with chassis 3:
UCS-A# scope org
UCS-A /org # create chassis-profile ch1
UCS-A /org/chassis-profile* # set disk-zoning-policy all56shared
UCS-A /org/chassis-profile* # commit-buffer
UCS-A /org/chassis-profile # associate chassis 3
UCS-A /org/fw-chassis-pack/pack-image #
Disk Migration
Before you can migrate a disk zoned from one server to another, you must mark the virtual drive(LUN) as transport ready or perform a hide virtual drive operation. This will ensure that all references from the service profile have been removed prior to disk migration. For more information on virtual drives, please refer to the
"virtual drives" section in the Cisco UCS Manager Storage Management Guide, Release 3.2.
Step 1
Step 2
Step 3
Procedure
Command or Action
UCS-A# scope chassis chassis-num
UCS-A /chassis# scope virtual-drive-container virtual-drive-container-num
UCS-A /chassis/virtual-drive-container# scope
virtual-drive virtual-drive--num
Purpose
Enters chassis mode for the specified chassis.
Enters the virtual drive container with the specified number.
Enters the virtual drive for the specified virtual drive container.
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
239
Cisco UCS S3260 System Storage Management
Storage Enclosure Operations
Step 4
Command or Action Purpose
UCS-A /chassis/virtual-drive-container/virtual-drive# scope
virtual-drive virtual-drive--num set admin-state admin-state
Specifies one of the following admin states for the virtual drive:
• clear-transport-ready — Sets the state of the virtual drive to no longer be transport ready.
• delete — Deletes the virtual drive.
• hide — Choose this option for the safe migration of the virtual drive from one server to another.
Note All virtual drives on a disk group must be marked as hidden before migrating or unassigning the disks from a server node.
• transport-ready — Choose this option for the safe migration of the virtual drive from one server to another.
Note When a virtual drive is marked as transport ready, the storage controller will disable all
IO operations on the drive. In addition, after zoning the virtual drive and importing the foreign configuration, the virtual drive will be operational.
Step 5 UCS-A /chassis/virtual-drive-container/virtual-drive# commit-buffer
Commits the transaction to the system configuration.
Example
The following example sets the state of the virtual drive 1001 in the virtual drive container 1 to transport ready:
UCS-A# scope chassis
UCS-A /chassis# scope virtual-drive-container 1
UCS-A /chassis/virtual-drive-container# scope virtual-drive 1001
UCS-A /chassis/virtual-drive-container/virtual-drive# set admin-state transport-ready
UCS-A /chassis/virtual-drive-container/virtual-drive# commit-buffer
Storage Enclosure Operations
Removing Chassis Level Storage Enclosures
You can remove the storage enclosure corresponding to HDD expansion tray in Cisco UCS Manager after it is physically removed. You cannot remove server level or any other chassis level storage enclosures.
240
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
Cisco UCS S3260 System Storage Management
SAS Expander Configuration Policy
Step 1
Step 2
Procedure
Command or Action
UCS-A# scope chassis chassis-id
UCS-A /chassis # remove storage-enclosure storage-enclosure-name
Purpose
Enters chassis mode for the specified chassis.
Removes the chassis level storage enclosure with the specified name.
Example
The following example removes storage enclosure 25 from chassis 2:
UCS-A# scope chassis 2
UCS-A /chassis# remove storage-enclosure 25
UCS-A /chassis#
SAS Expander Configuration Policy
Creating SAS Expander Configuration Policy
SUMMARY STEPS
1.
UCS-A# scope org org-name
2.
UCS-A org/ # create sas-expander-configuration-policy sas-expander-configuration-policy-name
3.
(Optional) UCS-A /org/sas-expander-configuration-policy* # set descr description
4.
(Optional) UCS-A /org/sas-expander-configuration-policy* # set 6g-12g-mixed-mode disabled|enabled|no-change
5.
UCS-A /org/sas-expander-configuration-policy* # commit-buffer
DETAILED STEPS
Step 1
Step 2
Step 3
Step 4
Command or Action
UCS-A# scope org org-name
Purpose
Enters organization mode for the specified organization.
To enter the root organization mode, type / as the org-name .
UCS-A org/ # create sas-expander-configuration-policy sas-expander-configuration-policy-name
Creates a SAS expander configuration policy with the specified policy name.
(Optional) UCS-A /org/sas-expander-configuration-policy*
# set descr description
Provides a description for the policy.
(Optional) UCS-A /org/sas-expander-configuration-policy*
# set 6g-12g-mixed-mode disabled|enabled|no-change
Note Enabling or disabling 6G-12G Mixed Mode causes system reboot.
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
241
Cisco UCS S3260 System Storage Management
Deleting a SAS Expander Configuration Policy
Command or Action Purpose
• Disabled —Connection Management is disabled in this policy and the Sas Expander uses only 6G speeds even if 12G is available.
• Enabled —Connection Management is enabled in this policy and it intelligently shifts between 6G and 12 G speeds based on availability.
• No Change (Default) —Pre-existing configuration is retained.
Commits the transaction to the system configuration.
Step 5 UCS-A /org/sas-expander-configuration-policy* # commit-buffer
Example
The following example creates the secp1 SAS expander configuration policy:
UCS-A# scope org
UCS-A /org # create sas-expander-configuration-policy secp1
UCS-A /org/sas-expander-configuration-policy*# set 6g-12g-mixed-mode enabled
UCS-A /org/sas-expander-configuration-policy*# commit-buffer
UCS-A /org/sas-expander-configuration-policy#
Deleting a SAS Expander Configuration Policy
SUMMARY STEPS
1.
UCS-A# scope org org-name
2.
UCS-A org/ # delete sas-expander-configuration-policy sas-expander-configuration-policy-name
3.
UCS-A /org* # commit-buffer
DETAILED STEPS
Step 1
Step 2
Step 3
Command or Action
UCS-A# scope org org-name
Purpose
Enters organization mode for the specified organization.
To enter the root organization mode, type / as the org-name .
UCS-A org/ # delete sas-expander-configuration-policy sas-expander-configuration-policy-name
Deletes a SAS expander configuration policy with the specified policy name.
UCS-A /org* # commit-buffer Commits the transaction to the system configuration.
Example
The following example deletes the secp1 SAS expander configuration policy:
242
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
Cisco UCS S3260 System Storage Management
Deleting a SAS Expander Configuration Policy
UCS-A# scope org
UCS-A /org # delete create sas-expander-configuration-policy secp1
UCS-A /org*# commit-buffer
UCS-A /org/#
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
243
Deleting a SAS Expander Configuration Policy
Cisco UCS S3260 System Storage Management
244
Cisco UCS Manager Storage Management Guide using the CLI, Release 4.2
Download
Advertisement