Cisco MDS 9000 NX-OS Software Release 9.2 Configuration Guide
Reklaam
Reklaam
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Americas Headquarters
Cisco Systems, Inc.
170 West Tasman Drive
San Jose, CA 95134-1706
USA http://www.cisco.com
Tel: 408 526-4000
800 553-NETS (6387)
Fax: 408 527-0883
THE SPECIFICATIONS AND INFORMATION REGARDING THE PRODUCTS IN THIS MANUAL ARE SUBJECT TO CHANGE WITHOUT NOTICE. ALL STATEMENTS,
INFORMATION, AND RECOMMENDATIONS IN THIS MANUAL ARE BELIEVED TO BE ACCURATE BUT ARE PRESENTED WITHOUT WARRANTY OF ANY KIND,
EXPRESS OR IMPLIED. USERS MUST TAKE FULL RESPONSIBILITY FOR THEIR APPLICATION OF ANY PRODUCTS.
THE SOFTWARE LICENSE AND LIMITED WARRANTY FOR THE ACCOMPANYING PRODUCT ARE SET FORTH IN THE INFORMATION PACKET THAT SHIPPED WITH
THE PRODUCT AND ARE INCORPORATED HEREIN BY THIS REFERENCE. IF YOU ARE UNABLE TO LOCATE THE SOFTWARE LICENSE OR LIMITED WARRANTY,
CONTACT YOUR CISCO REPRESENTATIVE FOR A COPY.
The Cisco implementation of TCP header compression is an adaptation of a program developed by the University of California, Berkeley (UCB) as part of UCB's public domain version of the UNIX operating system. All rights reserved. Copyright © 1981, Regents of the University of California.
NOTWITHSTANDING ANY OTHER WARRANTY HEREIN, ALL DOCUMENT FILES AND SOFTWARE OF THESE SUPPLIERS ARE PROVIDED “AS IS" WITH ALL FAULTS.
CISCO AND THE ABOVE-NAMED SUPPLIERS DISCLAIM ALL WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING, WITHOUT LIMITATION, THOSE OF
MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT OR ARISING FROM A COURSE OF DEALING, USAGE, OR TRADE PRACTICE.
IN NO EVENT SHALL CISCO OR ITS SUPPLIERS BE LIABLE FOR ANY INDIRECT, SPECIAL, CONSEQUENTIAL, OR INCIDENTAL DAMAGES, INCLUDING, WITHOUT
LIMITATION, LOST PROFITS OR LOSS OR DAMAGE TO DATA ARISING OUT OF THE USE OR INABILITY TO USE THIS MANUAL, EVEN IF CISCO OR ITS SUPPLIERS
HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES.
Any Internet Protocol (IP) addresses and phone numbers used in this document are not intended to be actual addresses and phone numbers. Any examples, command display output, network topology diagrams, and other figures included in the document are shown for illustrative purposes only. Any use of actual IP addresses or phone numbers in illustrative content is unintentional and coincidental.
All printed copies and duplicate soft copies of this document are considered uncontrolled. See the current online version for the latest version.
Cisco has more than 200 offices worldwide. Addresses and phone numbers are listed on the Cisco website at www.cisco.com/go/offices.
Cisco and the Cisco logo are trademarks or registered trademarks of Cisco and/or its affiliates in the U.S. and other countries. To view a list of Cisco trademarks, go to this URL: https://www.cisco.com/c/en/us/about/legal/trademarks.html
. Third-party trademarks mentioned are the property of their respective owners. The use of the word partner does not imply a partnership relationship between Cisco and any other company. (1721R)
© 2021 Cisco Systems, Inc. All rights reserved.
C O N T E N T S
P R E F A C E
C H A P T E R 1
C H A P T E R 2
C H A P T E R 3
Full Cisco Trademarks with Software License ?
Communications, Services, and Additional Information xx
Dynamic Port VSAN Membership 4
Distributed Device Alias Services 5
Fibre Channel Routing Services and Protocols 5
Configuring and Managing VSANs 7
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
iii
Contents
C H A P T E R 4
Reserved VSAN Range and Isolated VSAN Range Guidelines 12
Assigning Static Port VSAN Membership 13
Displaying VSAN Static Membership 14
Displaying Isolated VSAN Membership 16
Operational State of a VSAN 16
Displaying Static VSAN Configuration 18
Displaying Fabric Switch Information 19
DPVM Device Configuration (Static) 23
iv
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Contents
C H A P T E R 5
Disabling DPVM Distribution 27
DPVM Configuration Merge Guidelines 29
About Copying DPVM DPVM Configurations 29
Copying DPVM Active Configuration 30
Comparing Database Differences 30
Displaying DPVM Merge Status and Statistics 30
Displaying DPVM Configurations 31
Configuring and Managing Zones 37
Finding Feature Information 37
Feature History for Configuring and Managing Zones 38
Zone Member Configuration Guidelines 41
Active and Full Zoneset Considerations 41
Using the Quick Config Wizard 42
Guidelines and Limitations for Autozone 46
Configuring Autozone in Automatic Mode 47
Enabling Autozone in Automatic Mode 47
Executing Autozone in Manual mode 48
Enabling Autozone in Automatic Mode by a Remotely Authenticated (AAA) User 48
Disabling Autozone Automatic Mode 48
Displaying All the Zone Configurations 49
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
v
Contents
Displaying Pending Zone Configurations 49
Applying Pending Zone Configurations (Manual Mode) 49
Deleting Zones and Zoneset Created by Autozone 49
Example: Configuring Autozone 49
Verifying Autozone Configuration 51
About the Edit Local Full Zone Database Tool 55
Configuring a Zone Using the Zone Configuration Tool 59
Filtering End Devices Based on Name, WWN or FC ID 63
Adding Multiple End Devices to Multiple Zones 63
Activating a Zoneset Using DCNM SAN Client 65
Displaying Zone Membership Information 67
Overwrite Control for an Active Zoneset 67
Configuring the Default Zone Access Permission 69
Configuring the Default Zone Access Permission Using DCNM SAN Client 70
Creating FC Aliases Using DCNM SAN Client 72
Converting Zone Members to pWWN-Based Members 75
Creating Zone Sets and Adding Member Zones 75
Filtering Zones, Zone Sets, and Device Aliases Based on Name 77
Adding Multiple Zones to Multiple Zone Sets 77
Enabling Full Zoneset Distribution 78
vi
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Contents
Enabling Full Zoneset Distribution Using DCNM SAN Client 79
Enabling a One-Time Distribution 79
Enabling a One-Time Distribution Using DCNM SAN Client 80
About Recovering from Link Isolation 80
Importing and Exporting Zone Sets 81
Importing and Exporting Zone Sets Using DCNM SAN Client 81
Copying Zone Sets Using DCNM SAN Client 83
About Backing Up and Restoring Zones 84
Backing Up Zones Using DCNM SAN Client 84
Renaming Zones, Zone Sets, and Aliases 87
Renaming Zones, Zone Sets, and Aliases Using DCNM SAN Client 87
Cloning Zones, Zone Sets, FC Aliases, and Zone Attribute Groups 88
Cloning Zones, Zone Sets, FC Aliases, and Zone Attribute Groups Using DCNM SAN Client 89
Migrating a Non-MDS Database 89
Clearing the Zone Server Database 90
About Zone-Based Traffic Priority 90
Configuring Zone-Based Traffic Priority 91
Configuring Zone-Based Traffic Priority Using DCNM SAN Client 92
Configuring Default Zone QoS Priority Attributes 92
Configuring Default Zone QoS Priority Attributes Using DCNM SAN Client 93
Configuring the Default Zone Policy 94
Smart Zoning Member Configuration 95
Enabling Smart Zoning on a VSAN 95
Setting Default Value for Smart Zoning 96
Converting Zones Automatically to Smart Zoning 96
Configuring Device Types for Zone Members 97
Removing Smart Zoning Configuration 98
Disabling Smart Zoning at Zone Level in the Basic Zoning Mode 98
Disabling Smart Zoning at Zone Level for a VSAN in the Enhanced Zoning Mode 98
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
vii
Contents
Disabling Smart Zoning at Zone Level Using DCNM SAN Client 99
Displaying Zone Information 100
Changing from Basic Zoning to Enhanced Zoning 109
Changing from Enhanced Zoning to Basic Zoning 109
Enabling Enhanced Zoning Using DCNM SAN Client 110
Modifying the Zone Database 110
Enabling Automatic Zone Pending Diff Display 111
Releasing Zone Database Locks 111
Configuring Zone Merge Control Policies 123
Preventing Zones From Flooding FC2 Buffers 124
Permitting or Denying Traffic in the Default Zone 124
Configuring System Default Zoning Settings 125
Configuring Zone Generic Service Permission Settings 126
Displaying Enhanced Zone Information 126
Controlling Zoning Configuration Sessions 128
Configuring Zoning Session Limit 129
Compacting the Zone Database for Downgrading 129
F, TF, NP, and TNP Port Channels 141
E and TE Port Channels and IVR 142
Enhancing Zone Server Performance 145
Zone Server-Fibre Channel Name Server Shared Database 145
viii
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Contents
C H A P T E R 6
Enabling the Zone Server-FCNS Shared Database 145
Disabling Zone Server-FCNS shared database 145
Zone Server SNMP Optimization 146
Enabling Zone Server SNMP Optimization 146
Disabling Zone Server SNMP Optimization 147
Zone Server Delta Distribution 147
Enabling Zone Server Delta Distribution 147
Disabling Zone Server Delta Distribution 148
Distributing Device Alias Services 151
Understanding Device Aliases 151
Guidelines and Limitations 152
Device Alias Mode Distribution 153
Device Alias Diffs-Only Distribution 153
Configuring Device Alias Diffs-Only Distribution 153
Merging Device Alias with the Diffs-Only Distribution Feature Enabled 155
Merging Device Alias in Different Modes 155
Resolving Merge Failure and Device Alias Mode Mismatch 156
Zone Aliases Versus Device Aliases 157
About Device Alias Distribution 158
About Creating a Device Alias 159
About Device Alias Configuration Best Practices 159
Enabling the Device Alias Pending Diff Display 161
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
ix
Contents
C H A P T E R 7
Disabling and Enabling Device Alias Distribution 163
About Legacy Zone Alias Configuration Conversion 164
Device Alias Statistics Cleanup 165
Device Alias Configuration Verification 165
Resolving Device Alias Merge Failures 168
Device Alias Best Practices 168
Resolving Device Alias Mismatches 170
Resolving Duplicate Device Alias Names (Same Device Alias Name, Different pWWNs) 171
Resolving Duplicate pWWNs (Different Device Alias Names, Same pWWN) 173
Resolving a Validation Failure 176
Resolving Database Conflicts 178
Verifying the Device-Alias Database Status 179
Configuring Fibre Channel Routing Services and Protocols 181
Failover Scenarios for PortChannels and FSPF Links 183
About SPF Computational Hold Times 184
About Link State Record Defaults 184
Configuring FSPF on a VSAN 185
Resetting FSPF to the Default Configuration 185
Enabling or Disabling FSPF 185
Clearing FSPF Counters for the VSAN 186
FSPF Interface Configuration 186
x
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Contents
Configuring FSPF Link Cost 186
About Hello Time Intervals 187
Configuring Hello Time Intervals 187
Configuring Dead Time Intervals 188
About Retransmitting Intervals 188
Configuring Retransmitting Intervals 188
About Disabling FSPF for Specific Interfaces 189
Disabling FSPF for Specific Interfaces 189
Clearing FSPF Counters for an Interface 190
About Fibre Channel Routes 190
About Broadcast and Multicast Routing 190
About Multicast Root Switch 191
Setting the Multicast Root Switch 191
About Reordering Network Frames 196
About Reordering PortChannel Frames 197
About Enabling In-Order Delivery 197
Enabling In-Order Delivery Globally 198
Enabling In-Order Delivery for a VSAN 198
Displaying the In-Order Delivery Status 199
Configuring the Drop Latency Time 199
Displaying Latency Information 200
Flow Statistics Configuration 200
Counting Aggregated Flow Statistics 201
Counting Individual Flow Statistics 201
Displaying Flow Statistics 202
Displaying Global FSPF Information 202
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
xi
Contents
C H A P T E R 8
Displaying the FSPF Database 203
Displaying FSPF Interfaces 204
Managing FLOGI, Name Server, FDMI, and RSCN Databases 207
Enabling FLOGI Scale Optimization and Quiesce Timeout 208
Disabling FLOGI Scale Optimization and Quiesce Timeout 209
Bulk Notification Sent from the Name Server 211
Enabling Name Server Bulk Notification 212
Disabling Name Server Bulk Notification 212
Disabling Name Server Bulk Notification for NX-OS Release 6.2(9) 213
Re-enabling Name Server Bulk Notification 213
Name Server Proxy Registration 213
Registering Name Server Proxies 213
About Rejecting Duplicate pWWN 214
Name Server Database Entries 214
Optimizing Name Server Database Sync 215
Verifying the Number of Name Server Database Entries 215
Displaying Name Server Database Entries 215
Guidelines and Limitations for VMID 221
Configuring the VMID Server 222
xii
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Contents
C H A P T E R 9
C H A P T E R 1 0
Examples: Configuring the VMID Server 223
Verifying a VMID Configuration 223
Displaying RSCN Information 227
Configuring the multi-pid Option 228
Suppressing Domain Format SW-RSCNs 229
Enabling Coalesced SW-RSCNs 229
Disabling Coalesced SW-RSCNs 230
RSCN Timer Configuration Distribution Using CFS 231
Configuring the RSCN Timer 231
Verifying the RSCN Timer Configuration 232
RSCN Timer Configuration Distribution 232
Enabling RSCN Timer Configuration Distribution 233
Committing the RSCN Timer Configuration Changes 234
Discarding the RSCN Timer Configuration Changes 234
Displaying RSCN Configuration Distribution Information 235
About Starting SCSI LUN Discovery 237
Starting SCSI LUN Discovery 237
About Initiating Customized Discovery 238
Initiating Customized Discovery 238
Displaying SCSI LUN Information 239
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
xiii
Contents
MDS-Specific FICON Advantages 245
Fabric Optimization with VSANs 245
VSANs for FICON and FCP Mixing 246
Cisco MDS-Supported FICON Features 247
Default FICON Port Numbering Scheme 250
Implemented and Unimplemented Port Addresses 253
About the Reserved FICON Port Numbering Scheme 253
Installed and Uninstalled Ports 254
FICON Port Numbering Guidelines 254
Assigning FICON Port Numbers to Slots 254
Displaying the FICON Port Number Assignments 255
About Port Numbers for FCIP and PortChannel 255
Reserving FICON Port Numbers for FCIP and PortChannel Interfaces 256
About Enabling FICON on a VSAN 257
Enabling FICON on the Switch 258
Setting Up a Basic FICON Configuration 258
Manually Enabling FICON on a VSAN 261
Configuring the code-page Option 262
Allowing the Host to Move the Switch Offline 263
Allowing the Host to Change FICON Port Parameters 263
Allowing the Host to Control the Timestamp 264
Configuring SNMP Control of FICON Parameters 265
About FICON Device Allegiance 265
xiv
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Contents
Clearing FICON Device Allegiance 265
Automatically Saving the Running Configuration 266
Binding Port Numbers to PortChannels 267
Binding Port Numbers to FCIP Interfaces 268
Configuring the Default State for Port Prohibiting 270
Configuring Port Prohibiting 270
Assigning a Port Address Name 271
Specifying an RLIR Preferred Host 272
Displaying RLIR Information 273
About FICON Configuration Files 277
Applying the Saved Configuration Files to the Running Configuration 278
Editing FICON Configuration Files 278
Displaying FICON Configuration Files 279
Copying FICON Configuration Files 280
Swapping Ports on the Switch with Duplicate Port Numbers 282
Configuring FICON Tape Acceleration 284
Configuring FICON Tape Read Acceleration 285
Configuring XRC Acceleration 286
Moving a FICON VSAN to an Offline State 286
Displaying Control Unit Information 288
Displaying FICON Information 288
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
xv
Contents
C H A P T E R 1 1
Displaying FICON Port Address Information 289
Displaying FICON Configuration File Information 290
Displaying the Configured FICON State 292
Displaying a Port Administrative State 292
Displaying Buffer Information 293
Viewing the History Buffer 293
Displaying FICON Information in the Running Configuration 294
Displaying FICON Information in the Startup Configuration 294
Displaying FICON-Related Log Information 295
Advanced Features and Concepts 297
Fibre Channel Time-Out Values 297
Timer Configuration Across All VSANs 298
Timer Configuration Per-VSAN 298
About fctimer Distribution 299
Enabling fctimer Distribution 299
Committing fctimer Changes 300
Discarding fctimer Changes 300
Displaying Configured fctimer Values 301
Organizationally Unique Identifiers 302
Guidelines and Limitations 302
Configuration Examples for Adding and Deleting OUIs 303
Example: Adding and Deleting OUIs 303
Displaying WWN Information 303
Link Initialization WWN Usage 304
Configuring a Secondary MAC Address 304
xvi
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
C H A P T E R 1 2
Verifying the Company ID Configuration 307
Configuring Interop Mode 1 309
Configuring Interop Mode 1 311
Configuring Fibre Channel Common Transport Management Security 317
About Fibre Channel Common Transport 317
Configuring the Fibre Channel Common Transport Query 318
Verifying Fibre Channel Common Transport Management Security 318
Contents
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
xvii
Contents xviii
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Preface
This preface describes the audience, organization of, and conventions used in the Cisco MDS 9000 Series
Configuration Guides. It also provides information on how to obtain related documentation, and contains the following chapters:
•
•
Document Conventions, on page xix
•
Related Documentation, on page xx
•
Communications, Services, and Additional Information, on page xx
Audience
To use this installation guide, you need to be familiar with electronic circuitry and wiring practices, and preferably be an electronic or electromechanical technician.
Document Conventions
This document uses the following conventions:
Note Means reader take note . Notes contain helpful suggestions or references to material not covered in the manual.
Caution Means reader be careful . In this situation, you might do something that could result in equipment damage or loss of data.
Warnings use the following conventions:
Warning This warning symbol means danger. You are in a situation that could cause bodily injury. Before you work on any equipment, be aware of the hazards involved with electrical circuitry and be familiar with standard practices for preventing accidents. Use the statement number provided at the end of each warning to locate its translation in the translated safety warnings that accompanied this device. Statement 1071.
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
xix
Preface
Related Documentation
Related Documentation
The documentation set for the Cisco MDS 9000 Series Switches includes the following documents.
Release Notes http://www.cisco.com/c/en/us/support/storage-networking/mds-9000-nx-os-san-os-software/ products-release-notes-list.html
Regulatory Compliance and Safety Information http://www.cisco.com/c/en/us/td/docs/switches/datacenter/mds9000/hw/regulatory/compliance/RCSI.html
Compatibility Information http://www.cisco.com/c/en/us/support/storage-networking/mds-9000-nx-os-san-os-software/ products-device-support-tables-list.html
Installation and Upgrade http://www.cisco.com/c/en/us/support/storage-networking/mds-9000-nx-os-san-os-software/ products-installation-guides-list.html
Configuration http://www.cisco.com/c/en/us/support/storage-networking/mds-9000-nx-os-san-os-software/ products-installation-and-configuration-guides-list.html
CLI http://www.cisco.com/c/en/us/support/storage-networking/mds-9000-nx-os-san-os-software/ products-command-reference-list.html
Troubleshooting and Reference http://www.cisco.com/c/en/us/support/storage-networking/mds-9000-nx-os-san-os-software/ tsd-products-support-troubleshoot-and-alerts.html
To find a document online, use the Cisco MDS NX-OS Documentation Locator at: http://www.cisco.com/c/en/us/td/docs/storage/san_switches/mds9000/roadmaps/doclocater.html
Communications, Services, and Additional Information
• To receive timely, relevant information from Cisco, sign up at Cisco Profile Manager .
• To get the business impact you’re looking for with the technologies that matter, visit Cisco Services .
• To submit a service request, visit Cisco Support .
• To discover and browse secure, validated enterprise-class apps, products, solutions and services, visit
Cisco Marketplace .
• To obtain general networking, training, and certification titles, visit Cisco Press .
• To find warranty information for a specific product or product family, access Cisco Warranty Finder .
xx
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Preface
Preface
Cisco Bug Search Tool
Cisco Bug Search Tool (BST) is a web-based tool that acts as a gateway to the Cisco bug tracking system that maintains a comprehensive list of defects and vulnerabilities in Cisco products and software. BST provides you with detailed defect information about your products and software.
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
xxi
Preface
Preface xxii
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
C H A P T E R
1
New and Changed Information
•
Change Summary
This chapter lists the New and Changed features for this guide.
Table 1: New and Changed Features
Feature
Device Alias
New and Change Topics Changed in
Release
The default device alias mode is changed to enhanced mode.
8.5(1)
Zoning Single Session A new option to allow only a single configuration session at a time on a switch when in enhanced zoning mode.
8.4(2)
Autozone
Autozone
Autozone provides options to enable or disable automatically saving of the running configuration to the startup-configuration after making a zoning change, using the enableautosave and disableautosave options respectively.
8.4(1)
The Autozone feature is a mechanism to automate zoning via a single command or to allow minimal effort for deploying of fabric switches that support 32 Gbps or higher speed Fibre Channel interfaces.
8.3(1)
FLOGI Scale Optimization Changed the default FLOGI quiesce timeout value from
2000 to 0 millisecond.
8.3(1)
Virtual Machine Identifier
(VMID)
VMID support allows unique identification of virtual machines (VMs) by SAN fabric infrastructure.
8.2(1)
FLOGI Scale Optimization The FLOGI scale optimization feature enables users to increase the chassis-wide FLOGI scale limits. This feature is supported only on Cisco MDS 9718 Directors.
8.1(1)
Where Documented
FLOGI Scale Optimization, on page 207
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
1
New and Changed Information
Change Summary
Feature New and Change Topics
Zone Server Enhancements The Zone Server performance is enhanced using the following features:
• Zone Server FCNS Shared Database
• Zone Server SNMP Optimizations
• Zone Server Delta Distribution
Changed in
Release
7.3(0)D1(1)
Device Alias Diffs-only
Distribution
Organizationally Unique
Identifiers
When this feature is enabled on all the switches in a fabric, it enables better scalability.
7.3(0)D1(1)
This feature introduces a new command which enables dynamic addition of Organizationally Unique Identifiers
(OUIs) to the
7.3(0)D1(1) system OUI database.
Added pending-diff display on commit for zone and device-alias.
6.2(9) Confirm commit device-alias
Confirm commit zone
FC and FCOE Scale –
Device Alias
Fibre Channel Common
Transport Management
Server Query
Added “Device Alias Configuration Best Practices” section.
Configuring Fibre Channel Common Transport
Management Server Query
6.2(9)
6.2(9)
FCNS, RSCN
Where Documented
Management Security, on page 317
Smart Zoning
Smart Zoning
FICON Tape Read
Acceleration
Added bulk notification feature to improve the performance of all the components listening to FCNS database changes.
Added coalesced SWRSCN to improve RSCN performance.
6.2(7)
Added “Displaying Fabric Switch Information” section.
6.2(7)
Added the command output.
Added the Smart Zoning section.
Added “FICON Tape Acceleration” section.
6.2(7)
5.2.6
5.0(1a)
2
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
C H A P T E R
2
Fabric Overview
The Cisco MDS 9000 Family NX-OS command-line interface (CLI) can configure and manage features such as VSANs, SAN device virtualization, dynamic VSANs, zones, distributed device alias services, Fibre Channel routing services and protocols, FLOGI, name server, FDMI, RSCN database, SCSI targets, FICON, and other advanced features.
This chapter describes some of these features and includes the following topics:
•
•
Dynamic Port VSAN Membership, on page 4
•
SAN Device Virtualization, on page 4
•
•
Distributed Device Alias Services, on page 5
•
Fibre Channel Routing Services and Protocols, on page 5
•
Multiprotocol Support, on page 5
Virtual SANs
Virtual SAN (VSAN) technology partitions a single physical SAN into multiple VSANs. VSAN capabilities allow Cisco NX-OS software to logically divide a large physical fabric into separate, isolated environments to improve Fibre Channel SAN scalability, availability, manageability, and network security. For FICON,
VSANs facilitate hardware-based separation of FICON and open systems.
Each VSAN is a logically and functionally separate SAN with its own set of Fibre Channel fabric services.
This partitioning of fabric services greatly reduces network instability by containing fabric reconfigurations and error conditions within an individual VSAN. The strict traffic segregation provided by VSANs helps ensure that the control and data traffic of a specified VSAN are confined within the VSAN’s own domain, increasing SAN security. VSANs help reduce costs by facilitating consolidation of isolated SAN islands into a common infrastructure without compromising availability.
Users can create administrator roles that are limited in scope to certain VSANs. For example, a network administrator role can be set up to allow configuration of all platform-specific capabilities, while other roles can be set up to allow configuration and management only within specific VSANs. This approach improves the manageability of large SANs and reduces disruptions due to human error by isolating the effect of a user action to a specific VSAN whose membership can be assigned based on switch ports or the worldwide name
(WWN) of attached devices.
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
3
Fabric Overview
Dynamic Port VSAN Membership
VSANs are supported across FCIP links between SANs, which extends VSANs to include devices at a remote location. The Cisco MDS 9000 Family switches also implement trunking for VSANs. Trunking allows
Inter-Switch Links (ISLs) to carry traffic for multiple VSANs on the same physical link.
Dynamic Port VSAN Membership
Port VSAN membership on the switch is assigned on a port-by-port basis. By default each port belongs to the default VSAN. You can dynamically assign VSAN membership to ports by assigning VSANs based on the device WWN. This method is referred to as Dynamic Port VSAN Membership (DPVM). DPVM offers flexibility and eliminates the need to reconfigure the port VSAN membership to maintain fabric topology when a host or storage device connection is moved between two Cisco MDS switches or two ports within a switch. DPVM retains the configured VSAN regardless of where a device is connected or moved.
SAN Device Virtualization
Cisco SAN device virtualization (SDV) allows virtual devices representing physical end devices to be used for SAN configuration. Virtualization of SAN devices significantly reduces the time needed to swap out hardware. For example, if a storage array was replaced without using SDV, server downtime would be required for SAN zoning changes and host operating system configuration updates. With SDV, only the mapping between virtual and physical devices needs to change after hardware is swapped, insulating the SAN and end devices from extensive configuration changes.
Note SDV is not supported from Cisco MDS NX-OS Release 4.x and later.
Zoning
Zoning provides access control for devices within a SAN. Cisco NX-OS software supports the following types of zoning:
• N port zoning—Defines zone members based on the end-device (host and storage) port.
• WWN
• Fibre Channel identifier (FC-ID)
• Fx port zoning—Defines zone members based on the switch port.
• WWN
• WWN plus interface index, or domain ID plus interface index
• Domain ID and port number (for Brocade interoperability)
• iSCSI zoning—Defines zone members based on the host zone.
• iSCSI name
• IP address
4
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Fabric Overview
Distributed Device Alias Services
• LUN zoning—When combined with N port zoning, LUN zoning helps ensure that LUNs are accessible only by specific hosts, providing a single point of control for managing heterogeneous storage-subsystem access.
• Read-only zones—An attribute can be set to restrict I/O operations in any zone type to SCSI read-only commands. This feature is especially useful for sharing volumes across servers for backup, data warehousing, etc.
Note LUN zoning and read-only zones are not supported from Cisco MDS NX-OS Release 5.x and later.
• Broadcast zones—An attribute can be set for any zone type to restrict broadcast frames to members of the specific zone.
To provide strict network security, zoning is always enforced per frame using access control lists (ACLs) that are applied at the ingress switch. All zoning polices are enforced in hardware, and none of them cause performance degradation. Enhanced zoning session-management capabilities further enhance security by allowing only one user at a time to modify zones.
Distributed Device Alias Services
All switches in the Cisco MDS 9000 Family support Distributed Device Alias Services (device alias) on a per-VSAN basis and on a fabric-wide basis. Device alias distribution allows you to move host bus adapters
(HBAs) between VSANs without manually reentering alias names.
Fibre Channel Routing Services and Protocols
Fabric Shortest Path First (FSPF) is the standard path selection protocol used by Fibre Channel fabrics. The
FSPF feature is enabled by default on all Fibre Channel switches. You do not need to configure any FSPF services except in configurations that require special consideration. FSPF automatically calculates the best path between any two switches in a fabric. Specifically, FSPF is used to perform these functions:
• Dynamically compute routes throughout a fabric by establishing the shortest and quickest path between any two switches.
• Select an alternative path in the event of the failure of a given path. FSPF supports multiple paths and automatically computes an alternative path around a failed link. FSPF provides a preferred route when two equal paths are available.
Multiprotocol Support
In addition to supporting Fibre Channel Protocol (FCP), Cisco NX-OS software supports IBM Fibre Connection
(FICON), Small Computer System Interface over IP (iSCSI), and Fibre Channel over IP (FCIP) in a single platform. Native iSCSI support in the Cisco MDS 9000 Family switches helps customers consolidate storage for a wide range of servers into a common pool on the SAN.
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
5
Multiprotocol Support
Fabric Overview
6
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
C H A P T E R
3
Configuring and Managing VSANs
You can achieve higher security and greater stability in Fibre Channel fabrics by using virtual SANs (VSANs) on Cisco MDS 9000 Family switches and Cisco Nexus 5000 Series switches. VSANs provide isolation among devices that are physically connected to the same fabric. With VSANs you can create multiple logical SANs over a common physical infrastructure. Each VSAN can contain up to 239 switches and has an independent address space that allows identical Fibre Channel IDs (FC IDs) to be used simultaneously in different VSANs.
This chapter includes the following sections:
•
•
VSAN Configuration, on page 11
•
Displaying Static VSAN Configuration , on page 18
•
•
Displaying Fabric Switch Information, on page 19
About VSANs
A VSAN is a virtual storage area network (SAN). A SAN is a dedicated network that interconnects hosts and storage devices primarily to exchange SCSI traffic. In SANs, you use the physical links to make these interconnections. A set of protocols run over the SAN to handle routing, naming, and zoning. You can design multiple SANs with different topologies.
With the introduction of VSANs, the network administrator can build a single topology containing switches, links, and one or more VSANs. Each VSAN in this topology has the same behavior and property of a SAN.
A VSAN has the following additional features:
• Multiple VSANs can share the same physical topology.
• The same Fibre Channel IDs (FC IDs) can be assigned to a host in another VSAN, thus increasing VSAN scalability.
• Every instance of a VSAN runs all required protocols such as FSPF, domain manager, and zoning.
• Fabric-related configurations in one VSAN do not affect the associated traffic in another VSAN.
• Events causing traffic disruptions in one VSAN are contained within that VSAN and are not propagated to other VSANs.
This section describes VSANs and includes the following topics:
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
7
Configuring and Managing VSANs
VSANs Topologies
VSANs Topologies
The switch icons shown in both
Figure 1: Logical VSAN Segmentation, on page 8
and
Figure 2: Example of Two VSANs, on page 9
indicate that these features apply to any switch in the Cisco MDS 9000 Family.
Figure 1: Logical VSAN Segmentation, on page 8
shows a fabric with three switches, one on each floor.
The geographic location of the switches and the attached devices is independent of their segmentation into logical VSANs. No communication between VSANs is possible. Within each VSAN, all members can talk to one another.
Figure 1: Logical VSAN Segmentation
Figure 2: Example of Two VSANs, on page 9
shows a physical Fibre Channel switching infrastructure with two defined VSANs: VSAN 2 (dashed) and VSAN 7 (solid). VSAN 2 includes hosts H1 and H2, application servers AS2 and AS3, and storage arrays SA1 and SA4. VSAN 7 connects H3, AS1, SA2, and SA3.
8
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Configuring and Managing VSANs
Figure 2: Example of Two VSANs
VSANs Topologies
The four switches in this network are interconnected by trunk links that carry both VSAN 2 and VSAN 7 traffic. The inter-switch topology of both VSAN 2 and VSAN 7 are identical. This is not a requirement and a network administrator can enable certain VSANs on certain links to create different VSAN topologies.
Without VSANs, a network administrator would need separate switches and links for separate SANs. By enabling VSANs, the same switches and links may be shared by multiple VSANs. VSANs allow SANs to be built on port granularity instead of switch granularity.
Figure 2: Example of Two VSANs, on page 9
illustrates that a VSAN is a group of hosts or storage devices that communicate with each other using a virtual topology defined on the physical SAN.
The criteria for creating such groups differ based on the VSAN topology:
• VSANs can separate traffic based on the following requirements:
• Different customers in storage provider data centers
• Production or test in an enterprise network
• Low and high security requirements
• Backup traffic on separate VSANs
• Replicating data from user traffic
• VSANs can meet the needs of a particular department or application.
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
9
Configuring and Managing VSANs
VSAN Advantages
VSAN Advantages
VSANs offer the following advantages:
• Traffic isolation—Traffic is contained within VSAN boundaries and devices reside only in one VSAN ensuring absolute separation between user groups, if desired.
• Scalability—VSANs are overlaid on top of a single physical fabric. The ability to create several logical
VSAN layers increases the scalability of the SAN.
• Per VSAN fabric services—Replication of fabric services on a per VSAN basis provides increased scalability and availability.
• Redundancy—Several VSANs created on the same physical SAN ensure redundancy. If one VSAN fails, redundant protection (to another VSAN in the same physical SAN) is configured using a backup path between the host and the device.
• Ease of configuration—Users can be added, moved, or changed between VSANs without changing the physical structure of a SAN. Moving a device from one VSAN to another only requires configuration at the port level, not at a physical level.
Up to 256 VSANs can be configured in a switch. Of these, one is a default VSAN (VSAN 1), and another is an isolated VSAN (VSAN 4094). User-specified VSAN IDs range from 2 to 4093.
VSANs Versus Zones
You can define multiple zones in a VSAN. Because two VSANs are equivalent to two unconnected SANs, zone A on VSAN 1 is different and separate from zone A in VSAN 2.
Table 2: VSAN and Zone Comparison
lists the differences between VSANs and zones.
Table 2: VSAN and Zone Comparison
VSAN Characteristic Zone Characteristic
VSANs equal SANs with routing, naming, and zoning protocols.
Routing, naming, and zoning protocols are not available on a per-zone basis.
— Zones are always contained within a VSAN. Zones never span two VSANs.
Zones limit unicast traffic.
VSANs limit unicast, multicast, and broadcast traffic.
Membership is typically defined using the VSAN ID to Fx ports.
Membership is typically defined by the pWWN.
An HBA or a storage device can belong only to a single
VSAN—the VSAN associated with the Fx port.
An HBA or storage device can belong to multiple zones.
VSANs enforce membership at each E port, source port, and destination port.
VSANs are defined for larger environments (storage service providers).
VSANs encompass the entire fabric.
Zones enforce membership only at the source and destination ports.
Zones are defined for a set of initiators and targets not visible outside the zone.
Zones are configured at the fabric edge.
10
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Configuring and Managing VSANs
VSAN Configuration
Figure 3: VSANS with Zoning, on page 11
shows the possible relationships between VSANs and zones. In
VSAN 2, three zones are defined: zone A, zone B, and zone C. Zone C overlaps both zone A and zone B as permitted by Fibre Channel standards. In VSAN 7, two zones are defined: zone A and zone D. No zone crosses the VSAN boundary—they are completely contained within the VSAN. Zone A defined in VSAN 2 is different and separate from zone A defined in VSAN 7.
Figure 3: VSANS with Zoning
VSAN Configuration
VSANs have the following attributes:
• VSAN ID—The VSAN ID identifies the VSAN as the default VSAN (VSAN 1), user-defined VSANs
(VSAN 2 to 4093), and the isolated VSAN (VSAN 4094).
• State—The administrative state of a VSAN can be configured to an active (default) or suspended state.
Once VSANs are created, they may exist in various conditions or states.
• The active state of a VSAN indicates that the VSAN is configured and enabled. By enabling a
VSAN, you activate the services for that VSAN.
• The suspended state of a VSAN indicates that the VSAN is configured but not enabled. If a port is configured in this VSAN, it is disabled. Use this state to deactivate a VSAN without losing the
VSAN’s configuration. All ports in a suspended VSAN are disabled. By suspending a VSAN, you can preconfigure all the VSAN parameters for the whole fabric and activate the VSAN immediately.
• VSAN name—This text string identifies the VSAN for management purposes. The name can be from 1 to 32 characters long and it must be unique across all VSANs. By default, the VSAN name is a concatenation of VSAN and a four-digit string representing the VSAN ID. For example, the default name for VSAN 3 is VSAN0003.
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
11
Configuring and Managing VSANs
Reserved VSAN Range and Isolated VSAN Range Guidelines
Note A VSAN name must be unique.
• Load balancing attributes—These attributes indicate the use of the source-destination ID (src-dst-id) or the originator exchange OX ID (src-dst-ox-id, the default) for load balancing path selection.
Note OX ID based load balancing of IVR traffic from IVR- enabled switches is not supported on Generation 1 switching modules. OX ID based load balancing of IVR traffic from a non-IVR MDS switch should work.
Generation 2 switching modules support OX ID based load balancing of IVR traffic from IVR-enabled switches.
This section describes how to create and configure VSANs and includes the following topics:
Reserved VSAN Range and Isolated VSAN Range Guidelines
On an NPV switch with a trunking configuration on any interface, or on a regular switch where the f port-channel-trunk command is issued to enable the Trunking F Port Channels feature, follow these configuration guidelines for reserved VSANs and the isolated VSAN:
• If trunk mode is on for any of the interfaces or NP Port Channel is up, the reserved VSANs are 3040 to
4078, and they are not available for user configuration.
• The Exchange Virtual Fabric Protocol (EVFP) isolated VSAN is 4079, and it is not available for user configuration.
VSAN Creation
A VSAN is in the operational state if the VSAN is active and at least one port is up. This state indicates that traffic can pass through this VSAN. This state cannot be configured.
Creating VSANs Statically
You cannot configure any application-specific parameters for a VSAN before creating the VSAN.
Creating VSANs
To create VSANs, follow these steps:
Step 1
Step 2 switch# config terminal
Enters configuration mode.
switch(config)# vsan database switch(config-vsan-db)#
Configures the database for a VSAN. Application specific VSAN parameters cannot be configured from this prompt.
12
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Configuring and Managing VSANs
Port VSAN Membership
Step 3
Step 4
Step 5
Step 6
Step 7 switch(config-vsan-db)# vsan 2
Creates a VSAN with the specified ID (2) if that VSAN does not exist already.
switch(config-vsan-db)# vsan 2 name TechDoc updated vsan 2
Updates the VSAN with the assigned name (TechDoc).
switch(config-vsan-db)# vsan 2 suspend
Suspends the selected VSAN.
switch(config-vsan-db)# no vsan 2 suspend
Negates the suspend command issued in the previous step.
switch(config-vsan-db)# end switch#
Returns you to EXEC mode.
Port VSAN Membership
Port VSAN membership on the switch is assigned on a port-by-port basis. By default, each port belongs to the default VSAN. You can assign VSAN membership to ports using one of two methods:
• Statically—By assigning VSANs to ports.
See the
Assigning Static Port VSAN Membership, on page 13 .
• Dynamically—By assigning VSANs based on the device WWN. This method is referred to as dynamic port VSAN membership (DPVM).
See create_dynamic_vsan.ditamap#map_2861B3F48B334468BB9FBC52B85CC84A
Trunking ports have an associated list of VSANs that are part of an allowed list ( refer to the Cisco MDS 9000
Family NX-OS Interfaces Configuration Guide ).
Assigning Static Port VSAN Membership
To statically assign VSAN membership for an interface port, follow these steps:
Step 1
Step 2 switch# config terminal
Enters configuration mode.
switch(config)# vsan database switch(config-vsan-db)#
Configures the database for a VSAN.
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
13
Configuring and Managing VSANs
Displaying VSAN Static Membership
Step 3
Step 4
Step 5
Step 6
Step 7 switch(config-vsan-db)# vsan 2
Creates a VSAN with the specified ID (2) if that VSAN does not exist already.
switch(config-vsan-db)# vsan 2 interface fc1/8
Assigns the membership of the fc1/8 interface to the specified VSAN (VSAN 2).
switch(config-vsan-db)# vsan 7
Creates another VSAN with the specified ID (7) if that VSAN does not exist already.
switch(config-vsan-db)# vsan 7 interface fc1/8
Updates the membership information of the interface to reflect the changed VSAN.
switch(config-vsan-db)# vsan 1 interface fc1/8
Removes the interface fc1/8 from VSAN 7 to VSAN 1( the default VSAN).
To remove the VSAN membership of interface fc1/8 from VSAN 7, you should define the VSAN membership of fc1/8 to another VSAN.
The best practice is to assign it back to VSAN 1.
Displaying VSAN Static Membership
To display the VSAN static membership information, use the show vsan membership command (see
Membership Information for the Specified VSAN, on page 14
through
Displays Static Membership Information for a Specified Interface, on page 15 ).
Displays Membership Information for the Specified VSAN switch # show vsan 1 membership vsan 1 interfaces: fc1/1 fc1/2 fc1/3 fc1/4 fc1/5 fc1/6 fc1/7 fc1/9 fc1/10 fc1/11 fc1/12 fc1/13 fc1/14 fc1/15 fc1/16 port-channel 99
Note Interface information is not displayed if interfaces are not configured on this VSAN.
Displays Static Membership Information for All VSANs switch # show vsan membership vsan 1 interfaces: fc2/16 fc2/15 fc2/14 fc2/13 fc2/12 fc2/11 fc2/10 fc2/9 fc2/8 fc2/7 fc2/6 fc2/5 fc2/4 fc2/3 fc2/2 fc2/1 fc1/16 fc1/15 fc1/14 fc1/13 fc1/12 fc1/11 fc1/10 fc1/9 fc1/7 fc1/6 fc1/5 fc1/4 fc1/3 fc1/2 fc1/1 vsan 2 interfaces: fc1/8
14
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Configuring and Managing VSANs
Default VSAN vsan 7 interfaces: vsan 100 interfaces: vsan 4094(isolated vsan) interfaces:
Displays Static Membership Information for a Specified Interface switch # show vsan membership interface fc1/1 fc1/1 vsan:1 allowed list:1-4093
Default VSAN
The factory settings for switches in the Cisco MDS 9000 Family have only the default VSAN 1 enabled. We recommend that you do not use VSAN 1 as your production environment VSAN. If no VSANs are configured, all devices in the fabric are considered part of the default VSAN. By default, all ports are assigned to the default VSAN.
Note VSAN 1 cannot be deleted, but it can be suspended.
Note Up to 256 VSANs can be configured in a switch. Of these, one is a default VSAN (VSAN 1), and another is an isolated VSAN (VSAN 4094). User-specified VSAN IDs range from 2 to 4093.
Isolated VSAN
VSAN 4094 is an isolated VSAN. All non-trunking ports are transferred to this VSAN when the VSAN to which they belong is deleted. This avoids an implicit transfer of ports to the default VSAN or to another configured VSAN. All ports in the deleted VSAN are isolated (disabled).
Note When you configure a port in VSAN 4094 or move a port to VSAN 4094, that port is immediately isolated.
Caution Do not use an isolated VSAN to configure ports.
Note Up to 256 VSANs can be configured in a switch. Of these, one is a default VSAN (VSAN 1), and another is an isolated VSAN (VSAN 4094). User-specified VSAN IDs range from 2 to 4093.
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
15
Configuring and Managing VSANs
Displaying Isolated VSAN Membership
Displaying Isolated VSAN Membership
The show vsan 4094 membership command displays all ports associated with the isolated VSAN.
Operational State of a VSAN
A VSAN is in the operational state if the VSAN is active and at least one port is up. This state indicates that traffic can pass through this VSAN. This state cannot be configured.
Static VSAN Deletion
When an active VSAN is deleted, all of its attributes are removed from the running configuration. VSAN-related information is maintained by the system software as follows:
• VSAN attributes and port membership details are maintained by the VSAN manager. This feature is affected when you delete a VSAN from the configuration. When a VSAN is deleted, all the ports in that
VSAN are made inactive and the ports are moved to the isolated VSAN. If the same VSAN is recreated, the ports do not automatically get assigned to that VSAN. You must explicitly reconfigure the port VSAN membership (see
Figure 4: VSAN Port Membership Details, on page 16 )
Figure 4: VSAN Port Membership Details
• VSAN-based runtime (name server), zoning, and configuration (static routes) information is removed when the VSAN is deleted.
• Configured VSAN interface information is removed when the VSAN is deleted.
Note The allowed VSAN list is not affected when a VSAN is deleted (refer to the Cisco MDS 9000 Family NX-OS
Interfaces Configuration Guide ).
Any commands for a nonconfigured VSAN are rejected. For example, if VSAN 10 is not configured in the system, then a command request to move a port to VSAN 10 is rejected.
16
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Configuring and Managing VSANs
Deleting Static VSANs
Deleting Static VSANs
To delete a VSAN and its various attributes, follow these steps:
Step 1
Step 2
Step 3
Step 4
Step 5 switch# config terminal
Enters configuration mode.
switch(config)# vsan database
Configures the VSAN database.
switch-config-db# vsan 2 switch(config-vsan-db)#
Places you in VSAN configuration mode.
switch(config-vsan-db)# no vsan 5 switch(config-vsan-db)#
Deletes VSAN 5 from the database and switch.
switch(config-vsan-db)# end switch#
Places you in EXEC mode.
Load Balancing
Load balancing attributes indicate the use of the source-destination ID (src-dst-id) or the originator exchange
OX ID (src-dst-ox-id, the default) for load balancing path selection.
Configuring Load Balancing
To configure load balancing on an existing VSAN, follow these steps:
Step 1
Step 2
Step 3
Step 4 switch# config terminal
Enters configuration mode.
switch(config)# vsan database switch(config-vsan-db)#
Enters VSAN database configuration submode switch(config-vsan-db)# vsan 2
Specifies an existing VSAN.
switch(config-vsan-db)# vsan 2 loadbalancing src-dst-id
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
17
Configuring and Managing VSANs
Interop Mode
Step 5
Step 6
Step 7
Step 8
Step 9
Enables the load balancing guarantee for the selected VSAN and directs the switch to use the source and destination ID for its path selection process.
switch(config-vsan-db)# no vsan 2 loadbalancing src-dst-id
Negates the command issued in the previous step and reverts to the default values of the load balancing parameters.
switch(config-vsan-db)# vsan 2 loadbalancing src-dst-ox-id
Changes the path selection setting to use the source ID, the destination ID, and the OX ID (default).
switch(config-vsan-db)# vsan 2 suspend
Suspends the selected VSAN.
switch(config-vsan-db)# no vsan 2 suspend
Negates the suspend command issued in the previous step.
switch(config-vsan-db)# end switch#
Returns you to EXEC mode.
Interop Mode
Interoperability enables the products of multiple vendors to come into contact with each other. Fibre Channel standards guide vendors towards common external Fibre Channel interfaces. See the
Switch Interoperability, on page 307 .
FICON VSANs
You can enable FICON in up to eight VSANs. See the
FICON VSAN Prerequisites, on page 249 .
Displaying Static VSAN Configuration
Use the show vsan command to display information about configured VSANs (see Examples
Configuration for a Specific VSAN, on page 18
to
Displays All VSANs, on page 19 ).
Displays the Configuration for a Specific VSAN switch# show vsan 100 vsan 100 information name:VSAN0100 state:active in-order guarantee:no interoperability mode:no loadbalancing:src-id/dst-id/oxid
18
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Configuring and Managing VSANs
Default Settings
Displays the VSAN Usage switch# show vsan usage
4 vsan configured configured vsans:1-4 vsans available for configuration:5-4093
Displays All VSANs switch# show vsan vsan 1 information name:VSAN0001 state:active in-order guarantee:no interoperability mode:no loadbalancing:src-id/dst-id/oxid vsan 2 information name:VSAN0002 state:active in-order guarantee:no interoperability mode:no loadbalancing:src-id/dst-id/oxid vsan 7 information name:VSAN0007 state:active in-order guarantee:no interoperability mode:no loadbalancing:src-id/dst-id/oxid vsan 100 information name:VSAN0100 state:active in-order guarantee:no interoperability mode:no loadbalancing:src-id/dst-id/oxid vsan 4094:isolated vsan
Default Settings
Table 3: Default VSAN Parameters , on page 19
lists the default settings for all configured VSANs.
Table 3: Default VSAN Parameters
Parameters
Default VSAN
State
Name
Default
VSAN 1.
Active state.
Concatenation of VSAN and a four-digit string representing the VSAN ID. For example, VSAN 3 is VSAN0003.
Load-balancing attribute OX ID (src-dst-ox-id).
Displaying Fabric Switch Information
Use the show fabric switch information vsan command to display information about each switch in the fabric in the given VSAN.
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
19
Configuring and Managing VSANs
Displaying Fabric Switch Information
Displays Information about All the Switches in the Fabric switch# show fabric switch information vsan 100
VSAN 1:
----------------------------------------------------------------------------
SwitchName Model Version SupMemory
---------------------------------------------------------------------------huashan12 alishan-bgl-25
Hac18
Hac17
Coco1 switch#
DS-C9148-48P-K9
DS-C9250I-K9
DS-C9506
DS-C9506
DS-C9222I-K9
5.2(2d)
6.2(5a)
6.2(7)
6.2(5)
6.2(7) n/a n/a
2 GB n/a
1 GB
Note This command is not supported prior to Cisco NX-OS Release 6.2(7).
Note SUP memory is not displayed for the switches that are running Cisco NX-OS Release prior to 6.2(7).
Note Without the VSAN option, this command displays information about switches in all the VSANs.
20
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Creating Dynamic VSANs
C H A P T E R
4
This chapter includes the following sections:
•
•
•
DPVM Configuration Merge Guidelines, on page 29
•
Displaying DPVM Configurations, on page 31
•
Sample DPVM Configuration, on page 32
•
About DPVM
Port VSAN membership on the switch is assigned on a port-by-port basis. By default each port belongs to the default VSAN.
You can dynamically assign VSAN membership to ports by assigning VSANs based on the device WWN.
This method is referred to as Dynamic Port VSAN Membership (DPVM). DPVM offers flexibility and eliminates the need to reconfigure the port VSAN membership to maintain fabric topology when a host or storage device connection is moved between two Cisco MDS switches or two ports within a switch. It retains the configured VSAN regardless of where a device is connected or moved. To assign VSANs statically, see
Creating Dynamic VSANs, on page 21
.
DPVM configurations are based on port world wide name (pWWN) and node world wide name (nWWN) assignments. DPVM contains mapping information for each device pWWN/nWWN assignment and the corresponding VSAN. The Cisco NX-OS software checks DPVM active configuration during a device FLOGI and obtains the required VSAN details.
The pWWN identifies the host or device and the nWWN identifies a node consisting of multiple devices. You can assign any one of these identifiers or any combination of these identifiers to configure DPVM mapping.
If you assign a combination, then preference is given to the pWWN.
DPVM uses the Cisco Fabric Services (CFS) infrastructure to allow efficient database management and distribution. DPVM uses the application driven, coordinated distribution mode and the fabric-wide distribution scope (for information about CFS, refer to the Cisco MDS 9000 Series NX-OS System Management
Configuration Guide .
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
21
Creating Dynamic VSANs
About DPVM Configuration
Note DPVM does not cause any changes to device addressing. DPVM only pertains to the VSAN membership of the device, ensuring that the host gets the same VSAN membership on any port on the switch. For example, if a port on the switch has a hardware failure, you can move the host connection to another port on the switch and you do not need to update the VSAN membership manually.
Note DPVM is not supported on FL ports. DPVM is supported only on F ports.
This section describes DPVM and includes the following topics:
About DPVM Configuration
To use the DPVM feature as designed, be sure to verify the following requirements:
• The interface through which the dynamic device connects to the Cisco MDS 9000 Series switch must be configured as an F port.
• The static port VSAN of the F port should be valid (not isolated, not suspended, and in existence).
• The dynamic VSAN configured for the device in the DPVM database should be valid (not isolated, not suspended, and in existence).
• Device-alias must be in enhanced mode.
Note The DPVM feature overrides any existing static port VSAN membership configuration. If the VSAN corresponding to the dynamic port is deleted or suspended, the port is shut down.
Enabling DPVM
To begin configuring DPVM, you must explicitly enable DPVM on the required switches in the fabric. By default, this feature is disabled in all switches in the Cisco MDS 9000 Family.
The configuration and verification commands for DPVM are only available when DPVM is enabled on a switch. When you disable this feature, all related configurations are automatically discarded.
To enable DPVM on any participating switch, follow these steps:
Step 1
Step 2 switch# config t switch(config)#
Enters configuration mode.
switch(config)# feature dpvm
Enables DPVM on that switch.
22
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Creating Dynamic VSANs
DPVM Device Configuration (Static)
Step 3 switch(config)# no feature dpvm
Disables (default) DPVM on that switch.
Note To overwrite the login information with the duplicate pWWN login, enter the dpvm overwrite-duplicate-pwwn command.
DPVM Device Configuration (Static)
The DPVM device configuration consists of a series of device mapping entries. Each entry consists of a device pWWN or nWWN assignment along with the dynamic VSAN to be assigned. You can configure a maximum of 16,000 DPVM entries in the DPVM database. This database is global to the whole switch (and fabric) and is not maintained for each VSAN.
Configuring DPVM
To configure DPVM, follow these steps:
Step 1
Step 2
Step 3
Step 4
Step 5
Step 6
Step 7
Step 8
Step 9 switch# configure terminal
Enters configuration mode.
switch(config)# device-alias mode enhanced switch(config)# device-alias commit
Enables enhanced device alias mode.
switch(config)# dpvm database
Creates the DPVM config database.
switch(config)# no dpvm database
(Optional) Deletes the DPVM config database.
switch(config-dpvm-db)# pwwn 12:33:56:78:90:12:34:56 vsan 100
Maps the specified device pWWN to VSAN 100.
switch(config-dpvm-db)# no pwwn 12:33:56:78:90:12:34:56 vsan 101
(Optional) Removes the specified device pWWN mapping from the DPVM config database.
switch(config-dpvm-db)# nwwn 14:21:30:12:63:39:72:81 vsan 101
Maps the specified device nWWN to VSAN 101.
switch(config-dpvm-db)# no nwwn 14:21:30:12:63:39:72:80 vsan 101
(Optional) Removes the specified device nWWN mapping from the DPVM config database.
switch(config-dpvm-db)# device-alias device1 vsan 102
Maps the specified device-alias to VSAN 102.
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
23
Creating Dynamic VSANs
Activating DPVM
Step 10
Step 11
Step 12
Step 13 switch(config-dpvm-db)# no device-alias device1 vsan 102
(Optional) Removes the specified device-alias mapping from the DPVM config database.
switch(config-dpvm-db)# show dpvm pending
(Optional) When DPVM distribute is enabled (enabled by default when the feature is enabled) all configuration changes are held until they are committed. The list of pending changes can be seen at any time using this command.
switch(config-dpvm-db)# dpvm commit
(Optional) When DPVM distribute is enabled (enabled by default when the feature is enabled) this command is required to commit the configuration changes.
switch(config-dpvm-db)# show dpvm database
(Optional) Displays DPVM static device configuration.
Activating DPVM
Activating DPVM enforces the DPVM configuration. Activation may fail if there are conflicts between the already active configuration and the configuration to be activated. Activation can be forced to override the conflicting entries.
DPVM configuration can also be deactivated by issuing the no dpvm activate command.
To activate DPVM, follow these steps:
Step 1
Step 2
Step 3
Step 4
Step 5
Step 6 switch# configure terminal
Enters configuration mode.
switch(config)# dpvm activate
Activates the DPVM configuration.
switch(config)# no dpvm activate
Deactivates the currently active DPVM configuration.
switch(config)# dpvm activate force
Forcefully activates the DPVM configuration and overrides the conflicting entries.
switch(config)# dpvm commit
When DPVM distribute is enabled (enabled by default when the feature is enabled) this command is required to commit the configuration changes.
switch(config)# show dpvm database active
(Optional) Displays the enforced DPVM device configuration.
24
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Creating Dynamic VSANs
DPVM Autolearn
DPVM Autolearn
DPVM can be configured to automatically learn (autolearn) new devices within each VSAN. DPVM autolearn can be enabled or disabled at any time. Learned entries are created by populating device pWWNs and VSANs and can be using the show dpvm database active . DPVM should be activated before autolearn can be enabled.
Auto learned entries can also be manually deleted. The auto learned entries become permanent when DPVM auto learn is disabled.
Note Autolearn is only supported for devices connected to F ports. Devices connected to FL ports are not entered into the DPVM database because DPVM is not supported on FL ports.
The following conditions apply to learned entries:
• If a device logs out while autolearn is enabled, the corresponding autolearn entry is automatically deleted.
• If the same device logs multiple times into the switch through different ports, then the VSAN corresponding to last login is remembered.
• Learned entries do not override previously configured and activated entries.
• Learning is a two-part process—Enabling autolearning followed by disabling autolearning. When the auto-learn option is enabled, the following applies:
• Learning currently logged-in devices—Occurs from the time learning is enabled.
• Learning new device logins— Occurs as and when new devices log in to the switch.
Enabling Autolearn
To enable autolearn, follow these steps:
Step 1
Step 2
Step 3
Step 4
Step 5
Step 6 switch# configure terminal
Enters configuration mode.
switch(config)# dpvm auto-learn
Enables autolearn on the switch.
switch(config)# no dpvm auto-learn
Disables (default) autolearn on the switch.
switch(config)# clear dpvm auto-learn
Clears the list of autolearned entries.
switch(config)# clear dpvm auto-learn pwwn pwwn
Clears the list of autolearned pWWN entries in the distributed DPVM database.
switch(config)# dpvm commit
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
25
Creating Dynamic VSANs
Clearing Learned Entries
When DPVM distribute is enabled (enabled by default when feature is enabled) any change to DPVM autolearn has to be committed before it can take effect locally and in the fabric.
Clearing Learned Entries
You can clear DPVM entries from the active DPVM database (if autolearn is still enabled) using one of two methods.
• To clear a single autolearn entry, use the clear dpvm auto-learn pwwn command.
switch# clear dpvm auto-learn pwwn 55:22:33:44:55:66:77:88
• To clear all autolearn entries, use the clear dpvm auto-learn command.
switch# clear dpvm auto-learn
Note These two commands do not start a session and can only be issued in the local switch.
Disabling Autolearn
To disable autolearn, follow these steps:
Step 1
Step 2 switch# configure terminal
Enters configuration mode.
switch(config)# no dpvm auto-learn
Disables autolearn on the switch.
Note Running the no dpvm auto-learn command on other switches in the fabric before running the dpvm commit command helps to overcome the learnt conflict.
DPVM Distribution
If the DPVM configuration is available on all switches in the fabric, devices can be moved anywhere and offer the greatest flexibility. To enable database distribution to the neighboring switches, the database should be consistently administered and distributed across all switches in the fabric. The Cisco NX-OS software uses the Cisco Fabric Services (CFS) infrastructure to achieve this requirement (refer to the Cisco MDS 9000
NX-OS System Management Configuration Guide ).
This section describes how to distribute DPVM and includes the following topics:
26
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Creating Dynamic VSANs
About DPVM Distribution
About DPVM Distribution
Using the CFS infrastructure, each DPVM server learns the DPVM configuration from each of its neighboring switches during the ISL bring-up process. Any configuration changes done locally are distributed in the fabric and updated by all switches in the fabric.
With DPVM distribution enabled, all DPVM configuration changes are stored temporarily and committed only when the dpvm commit command is run. Changes include the following tasks:
• Adding, deleting, or modifying DPVM device configuration.
• Activating or deactivating DPVM.
• Enabling or disabling autolearn.
• DPVM copy active configuration.
These changes are distributed to all switches in a fabric with the dpvm commit command. Changes can also discard via the dvpm abort command.
Tip Temporary changes made can be viewed by the show dpvm pending or show dovm pending-diff commands.
Disabling DPVM Distribution
To disable DPVM distribution to the neighboring switches, follow these steps:
Step 1
Step 2
Step 3 switch# configure terminal switch(config)#
Enters configuration mode.
switch(config)# no dpvm distribute
Disables DPVM distribution to the neighboring switches.
switch(config)# dpvm distribute
Enables (default) DPVM distribution to the neighboring switches.
About Locking the Fabric
The first action that modifies the existing configuration creates the DPVM temporary storage and locks the feature in the fabric. Once the fabric is locked, no other user can make any further configuration changes to this feature.
Locking the Fabric
To lock the fabric and apply changes to the DPVM temporary storage, follow these steps:
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
27
Creating Dynamic VSANs
Committing Changes
Step 1
Step 2
Step 3
Step 4
Step 5 switch# config terminal
Enters configuration mode.
switch(config)# dpvm database switch(config-dpvm-db)#
Accesses the DPVM configuration.
switch(config-dpvm-db)# pwwn 11:22:33:44:55:66:77:88 vsan 11
Adds one entry to the DPVM configuration.
switch(config-dpvm-db)# exit
Exits to configuration mode.
switch(config)# dpvm activate
Run this command for the recent configuration changes to take effect.
Committing Changes
The dpvm commit command commits all the configuration changes made thus far on the local switch and also distributes the configurations to other switches in the fabric. On a successful commit, the configuration change is applied throughout the fabric and the lock is released.
To commit the DPVM configuration changes, follow these steps:
Step 1
Step 2 switch# configure terminal
Enters configuration mode.
switch(config)# dpvm commit
Commits the pending changes. The changes can be viewed using the show dpvm pending or the show dpvm pending-diff commands.
Discarding Changes
The dpvm abort discards all the temporary DPVM changes made thus far. The configurations remain unaffected and the lock is released.
To discard the DPVM configuration changes, follow these steps:
Step 1 switch# configure terminal
Enters configuration mode.
28
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Creating Dynamic VSANs
Clearing a Locked Session
Step 2 switch(config)# dpvm abort
Discards the database entries that are currently in the DPVM pending database. Discards all the pending DPVM changes.
Clearing a Locked Session
If DPVM lock is held and not released either by committing or by discarding the changes, an administrator can still clear the DPVM session from any switch in the fabric. When a DPVM session is cleared, all pending
DPVM changes are discarded and the fabric lock is released.
Tip Changes made to DPVM when distribution is enabled and held temporarily until the configuration changes are either committed or discarded. The configuration changes are discarded when the switch is restarted.
To use administrative privileges and release a locked DPVM session, use the clear dpvm session command in EXEC mode.
switch# clear dpvm session
DPVM Configuration Merge Guidelines
DPVM merge refers to a union of DPVM configuration across the fabric. For information about CFS merge support, refer to the Cisco MDS 9000 Family NX-OS System Management Configuration Guide for detailed concepts.
When merging the DPVM database between two fabrics, follow these guidelines:
• Verify that the activation status and the auto-learn status is the same is both fabrics.
• Verify that the combined number of device entries in each configuration does not exceed 16 K.
Caution If these conditions are not met, the merge will fail. The next distribution will forcefully synchronize the configurations and the activation states in the fabric.
This section describes how to merge DPVM configurations and includes the following topics:
About Copying DPVM DPVM Configurations
Note Fabric distribution is enabled and changes must be committed.
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
29
Creating Dynamic VSANs
Copying DPVM Active Configuration
Copying DPVM Active Configuration
To copy the currently active DPVM configurations to the DPVM static configuration, use the dpvm database copy command.
switch# dpvm database copy active
Legend: “+” New Entry, “-” Missing Entry, “*” Possible Conflict Entry
---------------------------------------------------------------------
pwwn 12:33:56:78:90:12:34:56 vsan 100
nwwn 14:21:30:12:63:39:72:81 vsan 101
Comparing Database Differences
Compare the DPVM configurations as follows:
• Use the dpvm database diff active command to compare the active DPVM configuration with the static
DPVM configuration.
switch# dpvm database diff active
Legend: “+” New Entry, “-” Missing Entry, “*” Possible Conflict Entry
---------------------------------------------------------------------
pwwn 44:22:33:44:55:66:77:88 vsan 44
* pwwn 11:22:33:44:55:66:77:88 vsan 11
• Use the dpvm database diff config command to compare the static DPVM configuration with the active
DPVM configuration.
switch# dpvm database diff config
Legend: “+” New Entry, “-” Missing Entry, “*” Possible Conflict Entry
---------------------------------------------------------------------
+ pwwn 44:22:33:44:55:66:77:88 vsan 44
* pwwn 11:22:33:44:55:66:77:88 vsan 22
• Use the show dpvm pending-diff command (when CFS distribution is enabled) to compare the pending
DPVM configuration changes.
Displaying DPVM Merge Status and Statistics
To display the DPVM configuration merge statistics, follow these steps:
Command Purpose
Displays the DPVM configuration merge statistics.
switch# show dpvm merge statistics
Clears the DPVM configuration merge statistics.
switch(config)# statistics clear dpvm merge switch(config)#
This example shows the conflicts in DPVM configuration merge:
30
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Creating Dynamic VSANs
Displaying DPVM Configurations switch# show dpvm merge status
Last Merge Time Stamp : Fri Aug 8 15:46:36 2008
Last Merge State
Last Merge Result
: Fail
: Fail
Last Merge Failure Reason : DPVM DB conflict found during merge [cfs_status: 76] Last Merge
Failure Details: DPVM merge failed due to database conflict
Local Switch WWN : 20:00:00:0d:ec:24:e5:00
Remote Switch WWN : 20:00:00:0d:ec:09:d5:c0
--------------------------------------------------------------------------
Conflicting DPVM member(s) Loc VSAN Rem VSAN
-------------------------------------------------------------------------dev-alias dpvm_dev_alias_1 [21:00:00:04:cf:cf:45:ba] dev-alias dpvm_dev_alias_2 [21:00:00:04:cf:cf:45:bb] dev-alias dpvm_dev_alias_3 [21:00:00:04:cf:cf:45:bc]
[Total 3 conflict(s)] rbadri-excal13#
1313
1313
1313
1414
1414
1414
This example shows the conflicts in DDAS mode: switch# show dpvm merge status
Last Merge Time Stamp
Last Merge State
: Fri Aug
: Fail
8 15:46:36 2008
Last Merge Result : Fail
Last Merge Failure Reason : DPVM DB conflict found during merge [cfs_status: 76] Last Merge
Failure Details: DPVM merge failed due to DDAS mode conflict
Local Switch WWN : 20:00:00:0d:ec:24:e5:00
Remote Switch WWN : 20:00:00:0d:ec:09:d5:c0
Local DDAS mode
Remote DDAS mode
: Basic
: Enhanced
Displaying DPVM Configurations
Use the show dpvm command to display information about WWNs configured on a per VSAN basis (see the following examples).
Displays the DPVM Configuration Status switch# show dpvm status
DB is activated successfully, auto-learn is on
Displays the DPVM Current Dynamic Ports for the Specified VSAN switch# show dpvm ports vsan 10
--------------------------------------------------------------
Interface Vsan Device pWWN Device nWWN
-------------------------------------------------------------fc1/2 10 29:a0:00:05:30:00:6b:a0 fe:65:00:05:30:00:2b:a0
Displays the DPVM Configuration switch# show dpvm database pwwn 11:22:33:44:55:66:77:88 vsan 11 pwwn 22:22:33:44:55:66:77:88 vsan 22 pwwn 33:22:33:44:55:66:77:88 vsan 33
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
31
Creating Dynamic VSANs
Sample DPVM Configuration pwwn 44:22:33:44:55:66:77:88 vsan 44
[Total 4 entries]
Displays the DPVM Active Configurations switch# show dpvm database active pwwn 11:22:33:44:55:66:77:88 vsan 22 pwwn 22:22:33:44:55:66:77:88 vsan 22 pwwn 33:22:33:44:55:66:77:88 vsan 33
[Total 3 entries]
* is auto-learnt entry
Displays DPVM Configurations switch# show dpvm database pwwn 11:22:33:44:55:66:77:88 vsan 11 pwwn 22:22:33:44:55:66:77:88 vsan 22 pwwn 33:22:33:44:55:66:77:88 vsan 33 pwwn 44:22:33:44:55:66:77:88 vsan 44
[Total 4 entries]
Shows Pending Changes with Respect to the DPVM Configurations switch# show dpvm pending-diff
Legend: “+” New Entry, “-” Missing Entry, “*” Possible Conflict Entry
---------------------------------------------------------------------
+ pwwn 55:22:33:44:55:66:77:88 vsan 55
pwwn 11:22:33:44:55:66:77:88 vsan 11
* pwwn 44:22:33:44:55:66:77:88 vsan 44
Sample DPVM Configuration
To configure a basic DPVM scenario, follow these steps:
Step 1
Step 2
Enable DPVM and enable DPVM distribution.
Example: switch1# configure terminal
Enter configuration commands, one per line.
End with CNTL/Z.
switch1(config)# feature dpvm switch1(config)# end switch1# show dpvm database switch1# show dpvm database active switch1# show dpvm status
At this stage, the configuration does not have an active DPVM configuration and the auto-learn option is disabled.
Activate a null (empty) configuration so that it can be populated with autolearned entries.
Example: switch1# configure terminal
Enter configuration commands, one per line.
End with CNTL/Z.
32
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Creating Dynamic VSANs
Sample DPVM Configuration
Step 3
Step 4 switch1(config)# dpvm activate switch1(config)# dpvm commit switch1(config)# end switch1# show dpvm database switch1# show dpvm database active switch1# show dpvm status
At this stage, the database is successfully activated and the auto-learn option continues to be disabled.
Enable the auto-learn option and commit the configuration changes.
Example: switch1# configure terminal
Enter configuration commands, one per line.
End with CNTL/Z.
switch1(config)# dpvm auto-learn switch1(config)# dpvm commit switch1(config)# end switch1# show dpvm database active pwwn 21:00:00:e0:8b:0e:74:8a vsan 4(*) pwwn 21:01:00:e0:8b:2e:87:8a vsan 5(*)
[Total 2 entries]
* is auto-learnt entry switch1# show dpvm ports
--------------------------------------------------------------
Interface Vsan Device pWWN Device nWWN
-------------------------------------------------------------fc1/24 4 21:00:00:e0:8b:0e:74:8a 20:00:00:e0:8b:0e:74:8a fc1/27 5 21:01:00:e0:8b:2e:87:8a 20:01:00:e0:8b:2e:87:8a switch1# show flogi database
---------------------------------------------------------------------------
INTERFACE VSAN FCID PORT NAME NODE NAME
--------------------------------------------------------------------------fc1/24 4 0xe70100 21:00:00:e0:8b:0e:74:8a 20:00:00:e0:8b:0e:74:8a fc1/27 5 0xe80100 21:01:00:e0:8b:2e:87:8a 20:01:00:e0:8b:2e:87:8a
Total number of flogi = 2.
switch195# show dpvm status
DB is activated successfully, auto-learn is on
At this stage, the currently logged in devices (and their current VSAN assignment) populate the active DPVM configuration.
However the entries are not yet permanent in the active DPVM configuration.
The output of the show dpvm ports and the show flogi database commands displays two other devices that have logged in (referred to as switch9 and switch3 in this sample configuration).
Access switch9 and issue the following commands:
Example: switch9# show dpvm database active pwwn 21:00:00:e0:8b:0e:87:8a vsan 1(*) pwwn 21:01:00:e0:8b:2e:74:8a vsan 1(*)
[Total 2 entries]
* is auto-learnt entry switch9# show dpvm status
DB is activated successfully, auto-learn is on
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
33
Sample DPVM Configuration
Step 5
Step 6
Step 7
Step 8
Access switch3 and issue the following commands:
Example: switch3# show dpvm database active pwwn 21:00:00:e0:8b:0e:76:8a vsan 1(*) pwwn 21:01:00:e0:8b:2e:76:8a vsan 1(*)
[Total 2 entries]
* is auto-learnt entry switch3# show dpvm status
DB is activated successfully, auto-learn is on
Disable autolearning in switch1 and commit the configuration changes.
Example: switch1# configure terminal
Enter configuration commands, one per line.
End with CNTL/Z.
switch1(config)# no dpvm auto-learn switch1(config)# dpvm commit switch1(config)# end switch1# show dpvm status
DB is activated successfully, auto-learn is off switch1# show dpvm database active pwwn 21:00:00:e0:8b:0e:74:8a vsan 4 pwwn 21:01:00:e0:8b:2e:87:8a vsan 5 pwwn 21:00:00:e0:8b:0e:87:8a vsan 1 pwwn 21:01:00:e0:8b:2e:74:8a vsan 1 pwwn 21:00:00:e0:8b:0e:76:8a vsan 1 pwwn 21:01:00:e0:8b:2e:76:8a vsan 1
[Total 6 entries]
* is auto-learnt entry switch1# show dpvm status
DB is activated successfully, auto-learn is off
At this stage, the autolearned entries are made permanent in the active DPVM configuration.
Access switch9 and issue the following commands:
Example: switch9# show dpvm database active pwwn 21:00:00:e0:8b:0e:87:8a vsan 1 pwwn 21:01:00:e0:8b:2e:74:8a vsan 1 pwwn 21:00:00:e0:8b:0e:76:8a vsan 1 pwwn 21:01:00:e0:8b:2e:76:8a vsan 1 pwwn 21:00:00:e0:8b:0e:74:8a vsan 4 pwwn 21:01:00:e0:8b:2e:87:8a vsan 5
[Total 6 entries]
* is auto-learnt entry switch9# show dpvm status
DB is activated successfully, auto-learn is off
Access switch3 and issue the following commands:
Example: switch3# show dpvm database active pwwn 21:00:00:e0:8b:0e:76:8a vsan 1 pwwn 21:01:00:e0:8b:2e:76:8a vsan 1
Creating Dynamic VSANs
34
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Creating Dynamic VSANs
Default Settings pwwn 21:00:00:e0:8b:0e:87:8a vsan 1 pwwn 21:01:00:e0:8b:2e:74:8a vsan 1 pwwn 21:00:00:e0:8b:0e:74:8a vsan 4 pwwn 21:01:00:e0:8b:2e:87:8a vsan 5
[Total 6 entries]
* is auto-learnt entry switch3# show dpvm status
DB is activated successfully, auto-learn is off
Note These basic steps help you determine that the information is identical in all the switches in the fabric.
You have now configured a basic DPVM scenario in a Cisco MDS 9000 Series switch.
Default Settings
Table 4: Default DPVM Parameters , on page 35
lists the default settings for DPVM parameters.
Table 4: Default DPVM Parameters
Parameters Default
DPVM
Autolearn
Disabled.
DPVM distribution Enabled.
Disabled.
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
35
Default Settings
Creating Dynamic VSANs
36
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
C H A P T E R
5
Configuring and Managing Zones
Zoning enables you to set up access control between storage devices or user groups. If you have administrator privileges in your fabric, you can create zones to increase network security and to prevent data loss or corruption.
Zoning is enforced by examining the source-destination ID field.
Advanced zoning capabilities specified in the FC-GS-4 and FC-SW-3 standards are provided. You can use either the existing basic zoning capabilities or the advanced, standards-compliant zoning capabilities.
•
Finding Feature Information, on page 37
•
Feature History for Configuring and Managing Zones, on page 38
•
•
•
Zone Configuration, on page 55
•
Zone Sets and FC Aliases, on page 63
•
ZoneSet Distribution, on page 78
•
Zoneset Duplication, on page 82
•
Advanced Zone Attributes, on page 90
•
Displaying Zone Information, on page 100
•
•
Controlling Zoning Configuration Sessions, on page 128
•
Compacting the Zone Database for Downgrading, on page 129
•
Zone and ZoneSet Analysis, on page 130
•
Zoning Best Practice, on page 133
•
Enhancing Zone Server Performance, on page 145
•
Zone Server SNMP Optimization, on page 146
•
Zone Server Delta Distribution, on page 147
•
Default Settings , on page 148
Finding Feature Information
Your software release might not support all the features documented in this module. For the latest caveats and feature information, see the Bug Search Tool at https://tools.cisco.com/bugsearch/ and the release notes for your software release. To find information about the features documented in this module, and to see a list of the releases in which each feature is supported, see the "New and Changed Information"chapter or the
Feature History table in this chapter.
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
37
Configuring and Managing Zones
Feature History for Configuring and Managing Zones
Feature History for Configuring and Managing Zones
lists the New and Changed features.
Table 5: New and Changed Features
Feature Name
Autozone
Zoning Single
Session
Releases Feature Information
8.5(1) • The maximum number of devices supported by zones in Autozone is increased to 250.
• Autozone can now be enabled on other VSANs apart from VSAN 1.
8.4(2)
The autozone --enable --vsan id command was modified.
Introduced the single session option for enhanced zoning mode.
The following commands were modified:
• [ no ] zone mode enhanced vsan id [ single-session ]
• show zone status vsan id
Autozone
Autozone
8.4(1) The enableautosave and disableautosave options are added to the autozone command to enable or disable automatically saving of the running configuration to the startup-configuration after making a zoning change.
The following commands were introduced:
• autozone --enable
• autozone --enableautosave
• autozone --disableautosave
8.3(1) The Autozone feature was introduced.
The following commands were introduced:
• autozone --delete
• autozone --disable
• autozone --help
• autozone --show
• autozone --showpending
• autozone --update
About Zoning
Zoning has the following features:
38
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Configuring and Managing Zones
About Zoning
• A zone consists of multiple zone members.
• Members in a zone can access each other; members in different zones cannot access each other.
• If zoning is not activated, all devices are members of the default zone.
• If zoning is activated, any device that is not in an active zone (a zone that is part of an active zoneset) is a member of the default zone.
• Zones can vary in size.
• Devices can belong to more than one zone.
• A zoneset consists of one or more zones.
• A zoneset can be activated or deactivated as a single entity across all switches in the fabric.
• Only one zoneset can be activated at any time.
• A zone can be a member of more than one zoneset.
• An MDS switch can have a maximum of 1000 zonesets.
• Zoning can be administered from any switch in the fabric.
• When you activate a zone (from any switch), all switches in the fabric receive the active zoneset.
Additionally, full zone sets are distributed to all switches in the fabric, if this feature is enabled in the source switch.
• If a new switch is added to an existing fabric, zone sets are acquired by the new switch.
• Zone changes can be configured nondisruptively. New zones and zone sets can be activated without interrupting traffic on unaffected ports or devices.
• Zone membership criteria is based mainly on WWNs or FC IDs.
• Port world wide name (pWWN)—Specifies the pWWN of an N port attached to the switch as a member of the zone.
• Fabric pWWN—Specifies the WWN of the fabric port (switch port’s WWN). This membership is also referred to as port-based zoning.
• FC ID—Specifies the FC ID of an N port attached to the switch as a member of the zone.
• Interface and switch WWN (sWWN)—Specifies the interface of a switch identified by the sWWN.
This membership is also referred to as interface-based zoning.
• Interface and domain ID—Specifies the interface of a switch identified by the domain ID.
• Domain ID and port number—Specifies the domain ID of an MDS domain and additionally specifies a port belonging to a non-Cisco switch.
• IPv4 address—Specifies the IPv4 address (and optionally the subnet mask) of an attached device.
• IPv6 address—The IPv6 address of an attached device in 128 bits in colon(:)-separated hexadecimal format.
• Symbolic-nodename—Specifies the member symbolic node name. The maximum length is 240 characters.
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
39
Configuring and Managing Zones
Zoning Example
• Default zone membership includes all ports or WWNs that do not have a specific membership association.
Access between default zone members is controlled by the default zone policy.
Note For configuration limits on configuring the number of zones, zone members and zone sets, refer to the Cisco
MDS NX-OS Configuration Limits .
Zoning Example
Figure 5: Fabric with Two Zones , on page 40
illustrates a zoneset with two zones, zone 1 and zone 2, in a fabric. Zone 1 provides access from all three hosts (H1, H2, H3) to the data residing on storage systems S1 and S2. Zone 2 restricts the data on S3 to access only by H3. Note that H3 resides in both zones.
Figure 5: Fabric with Two Zones
There are other ways to partition this fabric into zones.
Figure 6: Fabric with Three Zones , on page 40
illustrates another possibility. Assume that there is a need to isolate storage system S2 for the purpose of testing new software. To achieve this, zone 3 is configured, which contains only host H2 and storage S2. You can restrict access to just H2 and S2 in zone 3, and to H1 and S1 in zone 1.
Figure 6: Fabric with Three Zones
40
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Configuring and Managing Zones
Zone Implementation
Zone Implementation
All switches in the Cisco MDS 9000 Series automatically support the following basic zone features (no additional configuration is required):
• Zones are contained in a VSAN.
• Hard zoning cannot be disabled.
• Name server queries are soft-zoned.
• Only active zone sets are distributed.
• Unzoned devices cannot access each other.
• A zone or zoneset with the same name can exist in each VSAN.
• Each VSAN has a full database and an active database.
• Active zone sets cannot be changed, without activating a full zone database.
• Active zone sets are preserved across switch reboots.
• Changes to the full database must be explicitly saved.
• Zone reactivation (a zoneset is active and you activate another zoneset) does not disrupt existing traffic.
If required, you can additionally configure the following zone features:
• Propagate full zone sets to all switches on a per VSAN basis.
• Change the default policy for unzoned members.
• Interoperate with other vendors by configuring a VSAN in the interop mode. You can also configure one
VSAN in the interop mode and another VSAN in the basic mode in the same switch without disrupting each other.
• Bring E ports out of isolation.
Zone Member Configuration Guidelines
All members of a zone can communicate with each other. For a zone with N members, N *( N -1) access permissions need to be enabled. The best practice is to avoid configuring large numbers of targets or large numbers of initiators in a single zone. This type of configuration wastes switch resources by provisioning and managing many communicating pairs (initiator-to-initiator or target-to-target) that will never actually communicate with each other. For this reason, a single initiator with a single target is the most efficient approach to zoning.
The following guidelines must be considered when creating zone members:
• Configuring only one initiator and one target for a zone provides the most efficient use of the switch resources.
• Configuring the same initiator to multiple targets is accepted.
• Configuring multiple initiators to multiple targets is not recommended.
• While configuring a zone member based on interface type always select a fabric switch which potentially has the highest interface count in the fabric.
Active and Full Zoneset Considerations
Before configuring a zoneset, consider the following guidelines:
• Each VSAN can have multiple zone sets but only one zoneset can be active at any given time.
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
41
Configuring and Managing Zones
Using the Quick Config Wizard
• When you create a zoneset, that zoneset becomes a part of the full zoneset.
• When you activate a zoneset, a copy of the zoneset from the full zoneset is used to enforce zoning, and is called the active zoneset. An active zoneset cannot be modified. A zone that is part of an active zoneset is called an active zone.
• The administrator can modify the full zoneset even if a zoneset with the same name is active. However, the modification will be enforced only upon reactivation.
• When the activation is done, the active zoneset is automatically stored in persistent configuration. This enables the switch to preserve the active zoneset information across switch resets.
• All other switches in the fabric receive the active zoneset so they can enforce zoning in their respective switches.
• Hard and soft zoning are implemented using the active zoneset. Modifications take effect during zoneset activation.
• An FC ID or Nx port that is not part of the active zoneset belongs to the default zone and the default zone information is not distributed to other switches.
Note If one zoneset is active and you activate another zoneset, the currently active zoneset is automatically deactivated. You do not need to explicitly deactivate the currently active zoneset before activating a new zoneset.
Figure shows a zone being added to an activated zoneset.
Using the Quick Config Wizard
Note The Quick Config Wizard supports only switch interface zone members.
As of Cisco SAN-OS Release 3.1(1) and NX-OS Release 4.1(2), you can use the Quick Config Wizard on the Cisco MDS 9124 Switch to add or remove zone members per VSAN. You can use the Quick Config
Wizard to perform interface-based zoning and to assign zone members for multiple VSANs using Device
Manager.
Note The Quick Config Wizard is supported on Cisco MDS 9124, MDS 9134, MDS 9132T, MDS 9148, MDS
9148S, MDS 9148T, MDS 9396S, and MDS 9396T fabric switches, the Cisco Fabric Switch for HP c-Class
BladeSystem, and the Cisco Fabric Switch for IBM BladeCenter.
Caution The Quick Config Wizard can only be used on stand-alone switches that do not have any existing zoning defined on the switch.
42
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Configuring and Managing Zones
Using the Quick Config Wizard
To add or remove ports from a zone and to zone only the devices within a specific VSAN using Device
Manager on the Cisco MDS 9124 Switch, follow these steps:
Step 1 Choose FC > Quick Config or click the Zone icon in the toolbar.
You see the Quick Config Wizard (see
Figure 8: Quick Config Wizard, on page 44
) with all controls disabled and the
Discrepancies dialog box (see
Figure 7: Discrepancies Dialog Box, on page 43 ), which shows all unsupported
configurations.
Note You will see the Discrepancies dialog box only if there are any discrepancies.
Figure 7: Discrepancies Dialog Box
Step 2 Click OK to continue.
You see the Quick Config Wizard dialog box (see
Figure 8: Quick Config Wizard, on page 44 ).
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
43
Configuring and Managing Zones
Using the Quick Config Wizard
Note If there are discrepancies and you click OK , the affected VSANs in the zone databases are cleared. This may become disruptive if the switch is in use.
Figure 8: Quick Config Wizard
Step 3
Step 4
Step 5
Check the check box in the Ports Zoned To column for the port you want to add or remove from a zone. The check box for the matching port is similarly set. The selected port pair is added or removed from the zone, creating a two-device zone.
The VSAN drop-down menu provides a filter that enables you to zone only those devices within a selected VSAN.
Right-click any of the column names to show or hide a column.
Click Next to verify the changes.
You see the Confirm Changes dialog box (see
Figure 9: Confirm Changes Dialog Box, on page 45
).
44
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Configuring and Managing Zones
Figure 9: Confirm Changes Dialog Box
Autozone
Step 6
Step 7
If you want to see the CLI commands, right-click in the dialog box and click CLI Commands from the pop-up menu.
Click Finish to save the configuration changes.
Autozone
The Autozone feature is a mechanism to automate zoning of devices. This feature can be used to reduce the administrative overhead of manually creating and updating the switch zone configuration each time a device is added to the SAN to a one-time command. An administrator has to configure the Autozone feature after the initial deployment and does not have to manually change or modify the zone configuration each time a new device is added to a fabric. The Autozone feature is intended for fabrics comprise of a single fabric switch that has no more than 100 devices connected.
Initially, Autozone configures zoning that enables connectivity from every initiator to every target, based on the FC4 type registered by each device. The zones that are created are placed in a single zoneset in VSAN 1 and activated. When in automatic mode, a scheduler job is created to scan for newly logged in devices every
5 minutes. New initiators are zoned with all the targets and new targets are zoned with all the initiators. The new zones are then added to the active zoneset. This process allows the switch to be administered with minimal effort by simply plugging in new devices and having automatic connectivity for the devices within minutes.
Autozone can be run manually by the administrator if connectivity to the newly logged-in devices is required before the next scheduled scan. Autozone does not change the existing zones created either by Autozone or manually by an administrator. This prevents duplication of any existing zones by Autozone and allows specialized zones to be added manually by an administrator.
Autozone has two modes of operation:
• Automatic mode—The Autozone scheduler job runs every 5 minutes, checking for changes in device logins, and updates the zoneset accordingly.
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
45
Configuring and Managing Zones
Guidelines and Limitations for Autozone
• Manual mode—No scheduler job is created. The administrator has to run the autozone --update command each time a new device is connected to a switch for the device to be added to the zoning configuration.
Guidelines and Limitations for Autozone
• Works only on Cisco MDS 9132T, MDS 9148T, and MDS 9396T fabric switches.
• Works only on single-switch fabrics.
• From Cisco MDS NX-OS Release 8.5(1), Autozone can be enabled on VSANs apart from VSAN 1, but can be enabled on only one VSAN per switch.
• In Cisco MDS NX-OS Release 8.4(2b) and earlier release, Autozone works only for ports that are logged on VSAN 1. If the administrator moves ports to other VSANs, Autozone does not move them back into
VSAN 1 or zone them.
• If Autozone detects an active zoneset with a name different from AUTOZONESET, Autozone exits with a message without making any changes to the existing zone configuration.
• If Autozone detects an Inter-Switch Link (ISL), Autozone exits with a message, and no zones are created.
• Autozone will not work when the default zone is enabled.
• The Autozone feature considers only devices that are registered as FC4 type init or target . Any other types are ignored and must be zoned manually by the administrator.
• Starting with Cisco MDS NX-OS Release 8.5(1), the Autozone feature zones a maximum of 250 devices.
In releases prior to Cisco MDS NX-OS Release 8.5(1), Autozone feature zones a maximum of 100 devices.
• The Autozone feature does not support Smart Zoning.
• Avoid enabling the Autozone feature if you want to use the Inter VSAN Routing (IVR) feature.
• Avoid creating a manual zone of the name format AUTOZONE_< SwitchSerialNumber >_< number > because this is the format that is used by Autozone to create zone names. Autozone will delete zones with this name format when you use the autozone --delete command.
• When Autozone is first run in automatic mode, it creates a scheduler job called
AUTOZONE_SCHEDULER_JOB and a schedule called AUTOZONE_SCHEDULER_SCHEDULE to run the autozone --update command every 5 minutes. If either the scheduler job or schedule is deleted by the administrator, then periodic zone updates by Autozone will cease.
• When Autozone is enabled and if a zone lock or zone single-session lock is acquired, you will have to clear the zone lock using the clear zone lock vsan command and then retry Autozone configuration.
• When Autozone is configured in automatic mode and you execute the show accounting log command, there will be entries with an empty command field each time the Autozone scheduler job is run. This is expected.
• Cisco NX-OS releases that support the Autozone feature creates a CLI alias named autozone when the switch boots. Even if the autozone --enable command is not run, this configuration change triggers the
"Unsaved configuration" warning during an upgrade. Ensure that you save the configuration to prevent this message during future upgrades. As a best practice, we recommend that you copy the running configuration to the startup configuration on the switch before upgrading.
46
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Configuring and Managing Zones
Configuring Autozone in Automatic Mode
• If you have the Autozone feature enabled and you are downgrading from Cisco MDS NX-OS Release
8.3(1) to earlier releases that do not support the Autozone feature, the Autozone scheduler job continues to check for new device logins every 5 minutes. However, the scheduler job fails if any new device logins are detected, and generates a syslog. Therefore, we recommend that you disable Autozone before downgrading.
• If you have the Autozone feature enabled and you are downgrading from Cisco MDS NX-OS Release
8.4(1) to earlier releases that do not support the Autozone feature, the autozone --enable CLI alias command is available. However, when you execute the command, it fails. You may delete the autozone
CLI alias name using the cli alias name autozone command.
• Do not delete the autozone CLI alias name to ensure that the Autozone feature functions as documented.
• If the Autozone feature is enabled, during upgrade or downgrade, the Autozone scheduler job might temporarily fail. The scheduler job resumes executing successfully after the upgrade or downgrade is complete.
Configuring Autozone in Automatic Mode
The Autozone feature creates zones and a zoneset on VSAN 1 for unzoned devices and creates a scheduler job to periodically add new device logins on VSAN 1.
Enabling Autozone in Automatic Mode
Before you begin
Review the
Guidelines and Limitations for Autozone, on page 46
.
Enable autozone to automatically create zones, add them to a zoneset, and activate the zoneset as needed every 5 minutes: switch# autozone --enable --vsan id
Note --vsan id is optional and defaults to VSAN 1.
Enabling Autosave
To enable autozone to automatically save the running-configuration to the startup-configuration after it makes a zoning change, perform the step below:
Before you begin
Enable Autozone in Automatic Mode.
Enable automatic saving of the autozone configuration: switch# autozone --enableautosave
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
47
Configuring and Managing Zones
Executing Autozone in Manual mode
Executing Autozone in Manual mode
You can execute Autozone manually for updating the zoning information each time a new device is logged into the switch.
To execute Autozone in manual mode, perform this step: switch# autozone --update
Enabling Autozone in Automatic Mode by a Remotely Authenticated (AAA) User
An Autozone scheduler job runs using the identity of a user who has enabled the Autozone feature on the switch. If the user has remote authentication (AAA), the user's credentials must be added manually to the scheduler configuration for the periodic Autozone scheduler job to succeed.
To enable the Autozone feature for a remotely authenticated user, perform these steps:
Step 1
Step 2
Step 3
Step 4
Enter global configuration mode: switch# configure
Enable the command scheduler: switch(config)# feature scheduler
Configure a cleartext password for a remotely authenticated user: switch(config)# scheduler aaa-authentication user name password password
Create zones and a zoneset on a VSAN automatically and schedule a timer to check for new device logins: switch(config)# autozone --enable --vsan id
Note --vsan id is optional and defaults to VSAN 1.
Disabling Autosave
To disable autozone from automatically saving the running-configuration to the startup-configuration after it makes a zoning change, perform the step below:
Disable automatic saving of the autozone configuration: switch# autozone --disableautosave
Disabling Autozone Automatic Mode
To prevent new devices from being zoned automatically and retaining the existing zone configuration, run this command: switch# autozone --disable
48
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Configuring and Managing Zones
Displaying All the Zone Configurations
Displaying All the Zone Configurations
To display the Autozone status, the existing zone and zoneset configuration created by Autozone, and the zoning configuration that Autozone would create for unzoned devices that are currently logged in to a switch, run this command: switch# autozone --show
Displaying Pending Zone Configurations
To display only the zone configuration changes which Autozone configures for unzoned devices before the
Autozone scheduler job is run, run this command: switch# autozone --showpending
Applying Pending Zone Configurations (Manual Mode)
By default, if the Autozone feature is enabled, the Autozone scheduler job automatically runs every 5 minutes.
However, to optionally force Autozone to run before the end of the 5-minute cycle or to run Autozone without creating the Autozone scheduler job, run this command: switch# autozone --update
Deleting Zones and Zoneset Created by Autozone
To delete all the zones and the zoneset created by Autozone on VSAN 1, run this command: switch# autozone --delete
Note Deleting the zones and zoneset created by Autozone does not disable the Autozone feature. To disable the
Autozone feature, use the autozone --disable command. We recommend that you use the autozone --disable command before using the autozone --delete command because Autozone reconfigures all the zones again if it is enabled and the devices are still connected. Optionally, you can use both the options together using the autozone --disable --delete command.
Example: Configuring Autozone
The following example shows how to enable Autozone in automatic mode. In this mode, all currently logged in devices are zoned and new logins are automatically added periodically. In this example, a device without a suitable FC4 type is detected and not included in the zone configuration.
switch# autozone --enable --vsan 1
This command will automatically create and activate single-initiator and single-target zones for all end-devices currently logged-in to VSAN 1; all initiators will be zoned to all targets. This may lead to a large TCAM and RSCN load on the switch. Please use AutoZone judiciously.
AutoZone feature is enabled
Device with pwwn 10:00:00:de:fb:74:e8:31 is not registered with FC4-type Init or Target.
Hence, it will be ignored for AutoZone configuration.
Configuring zones for vsan 1
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
49
Configuring and Managing Zones
Example: Configuring Autozone
AUTOZONE_JPG21190082_1
Configuring zoneset for vsan 1
Activating the zoneset. Please wait...
Configured zoneset AUTOZONESET for vsan 1 successfully.
The following example shows how to enable Autozone in automatic mode on VSAN 2: switch# autozone --enable --vsan 2
This command will automatically create and activate single-initiator and single-target zones for all end-devices currently logged-in to VSAN 2; all initiators will be zoned to all targets. This may lead to a large TCAM and RSCN load on the switch. Please use AutoZone judiciously.
AutoZone feature is enabled
Device with pwwn 10:00:00:de:fb:74:e8:31 is not registered with FC4-type Init or Target.
Hence, it will be ignored for AutoZone configuration.
Configuring zones for vsan 2
AUTOZONE_JPG21190082_1
Configuring zoneset for vsan 2
Activating the zoneset. Please wait...
Configured zoneset AUTOZONESET for vsan 2 successfully.
The following example shows how to execute the Autozone feature once to zone all the unzoned devices logged in on VSAN 1, and add them to the active zoneset of VSAN 1 without creating the
Autozone scheduler job. A device without a suitable FC4 type is detected and not included in the zone configuration.
switch# autozone --update
Device with pwwn 10:00:00:de:fb:74:e8:31 is not registered with FC4-type Init or Target.
Hence, it will be ignored for AutoZone configuration.
Configuring zones for vsan 1
AUTOZONE_JPG21190082_1
AUTOZONE_JPG21190082_2
AUTOZONE_JPG21190082_3
AUTOZONE_JPG21190082_4
Configuring zoneset for vsan 1
Activating the zoneset. Please wait...
Configured zoneset AUTOZONESET for vsan 1 successfully.
The following example shows how to disable the Autozone feature so that newly logged-in devices are not zoned while retaining the existing zone configuration: switch# autozone --disable
This will disable the AutoZone feature. Do you wish to continue? [y/n]|y: y
AutoZone feature disabled successfully.
The following example shows how to delete the Autozone and zoneset created for VSAN 1: switch# autozone --delete
Checking if zoneset name AUTOZONESET present on switch...[Found]
Checking if AutoZone is enabled on switch...[Disabled]
This option will only delete the zone/zoneset configurations done by AutoZone feature.
50
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Configuring and Managing Zones
Verifying Autozone Configuration
Do you wish to continue? [n]|y: y
Deleting zoneset name AUTOZONESET and all zones for vsan 1 configured by AutoZone
Deleting following zones -
AUTOZONE_JPG21190082_1
AUTOZONE_JPG21190082_2
AUTOZONE_JPG21190082_3
AUTOZONE_JPG21190082_4
Deactivating zoneset for vsan 1.
Deactivated zoneset for vsan 1.
Verifying Autozone Configuration
The following example displays the Autozone status, the zones already created, as well as uncreated (pending) zones, by Autozone: switch# autozone --show
Feature AutoZone : Enabled
AutoSave Configuration : Enabled
The possible zone/zoneset configuration with AutoZone feature for currently logged-in devices is : zoneset name AUTOZONESET vsan 1 zone name AUTOZONE_JPG21190082_1 vsan 1 member pwwn 20:00:00:11:0d:97:00:01 member pwwn 20:01:00:11:0d:97:01:01 zone name AUTOZONE_JPG21190082_2 vsan 1 member pwwn 20:00:00:11:0d:97:00:01 member pwwn 20:01:00:11:0d:97:01:00 zone name AUTOZONE_JPG21190082_3 vsan 1 member pwwn 20:00:00:11:0d:97:00:00 member pwwn 20:01:00:11:0d:97:01:01 zone name AUTOZONE_JPG21190082_4 vsan 1 member pwwn 20:00:00:11:0d:97:00:00 member pwwn 20:01:00:11:0d:97:01:00
The following example shows how to check for the zoning configuration that Autozone creates for any unzoned devices and then apply those changes. In this example, Autozone is disabled so that zoning is updated only once and there is no periodic zoning by Autozone.
switch# autozone --showpending
Feature AutoZone : Disabled zoneset name AUTOZONESET vsan 1 zone name AUTOZONE_JPG21190082_1 vsan 1 member pwwn 20:00:00:11:0d:97:00:00 member pwwn 20:01:00:11:0d:97:01:00 switch# autozone --update
Configuring zones for vsan 1
AUTOZONE_JPG21190082_1
Configuring zoneset for vsan 1
Activating the zoneset. Please wait...
Configured zoneset AUTOZONESET for vsan 1 successfully.
The following example shows how to verify if the Autozone feature is already enabled and if there are currently unzoned devices: switch# autozone --showpending
Feature AutoZone : Enabled
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
51
Configuring and Managing Zones
Autozone Example Scenario zoneset name AUTOZONESET vsan 1 zone name AUTOZONE_JPG21190082_2 vsan 1 member pwwn 20:00:00:11:0d:97:00:01 member pwwn 20:01:00:11:0d:97:01:00 zone name AUTOZONE_JPG21190082_3 vsan 1 member pwwn 20:00:00:11:0d:97:00:00 member pwwn 20:01:00:11:0d:97:01:01 zone name AUTOZONE_JPG21190082_4 vsan 1 member pwwn 20:00:00:11:0d:97:00:01 member pwwn 20:01:00:11:0d:97:01:01
The following example shows how to obtain information about the autozone command: switch# autozone --help usage: autozone.py [-h] [--enable] [--disable] [--update] [--delete] [--show]
[--showpending] [--enableautosave] [--disableautosave]
[--vsan VSAN]
Enables AutoZone feature for vsan 1 optional arguments:
-h, --help
--enable
--disable show this help message and exit
Enables AutoZone automatic mode for VSAN 1. New devices logging in will be zoned automatically. No changes will be done for existing configuration. To have autzone automatically save the running configuration to startup configuration include the --enable argument followed by
--enableautosave argument.
Disables AutoZone feature for VSAN 1. New devices logging in will not be zoned automatically. No changes will be done for existing configuration.
--update
--delete
--show
Computes and applies any pending AutoZone configuration to switch for vsan 1
Deletes zone/zoneset configuration done by AutoZone for VSAN
1
Displays the current active zone/zonset configuration done by
--showpending
Autozone for VSAN 1.
Displays only zoning configuration that is pending and not yet applied on the switch.
--enableautosave Enables Auto saving of running configuration to startup configuration whenever an automatic zoning change is done. Allowed with the --enable argument and --update argument respectively.
--disableautosave Disables Auto saving of running configuration to startup configuration whenever an automatic zoning change is done.. To save any automatic zoning changes to startup,
--vsan VSAN
"copy running-config startup-config" must be manually executed.
Please provide VSAN between 1-4093
Autozone Example Scenario
Let us consider a topology where two devices—Initiator 1 and Target 1—are logged on to a Cisco MDS switch. We configure the Autozone feature on the switch and verify the zone configuration for these devices.
Then, we introduce two new devices—Initiator 2 and Target 2—to this network and verify if they are automatically configured in the zone.
52
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Configuring and Managing Zones
Figure 10: Autozone Example Topology
Autozone Example Scenario
1.
Verify the existing zone configuration using the show zoneset active vsan 1 command: switch# show zoneset active vsan 1
Zoneset not present
2.
Verify the existing device logins using the show fcns database command: switch# show fcns database
VSAN 1:
-----------------------------------------------------------------------
FCID TYPE PWWN (VENDOR) FC4-TYPE:FEATURE
-----------------------------------------------------------------------
0xee0000 N 20:00:00:11:0d:97:00:00 scsi-fcp:init
0xee0020
0xee0400
N
N
20:01:00:11:0d:97:01:00 scsi-fcp:target
10:00:00:de:fb:74:e8:31 (Cisco) ipfc
Total number of entries = 2
3.
Create zones and a zoneset on VSAN 1 automatically and schedule a timer to check for new device logins on the Cisco MDS switch using the autozone --enable command: switch# autozone --enable
This command will create and activate single-initiator and single-target zones for all end-devices are already logged-in automatically; that may lead to more tcam entries and also RSCN load on network. Please use AutoZone judiciously.
AutoZone feature is enabled
Device with pwwn 10:00:00:de:fb:74:e8:31 is not registered with FC4-type Init or Target.
Hence, it will be ignored for AutoZone configuration.
Configuring zones for vsan 1
AUTOZONE_JPG21190082_1
Configuring zoneset for vsan 1
Activating the zoneset. Please wait...
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
53
Configuring and Managing Zones
Autozone Example Scenario
Configured zoneset AUTOZONESET for vsan 1 successfully.
4.
Verify the zone configuration using the show zoneset active vsan 1 command: switch# show zoneset active vsan 1 zoneset name AUTOZONESET vsan 1 zone name AUTOZONE_JPG21190082_1 vsan 1
* fcid 0xee0000 [pwwn 20:00:00:11:0d:97:00:00]
* fcid 0xee0020 [pwwn 20:01:00:11:0d:97:01:00]
You can see that a new zoneset named AUTOZONESET is created and a new zone of the format
AUTOZONE_<SwitchSerialNumber>_<number> is created and the devices are added to this zoneset:
5.
Add Initiator 2 and Target 2 to the network:
6.
Verify the new device logins using the show fcns database command: switch# show fcns database
VSAN 1:
-----------------------------------------------------------------------
FCID TYPE PWWN (VENDOR) FC4-TYPE:FEATURE
-----------------------------------------------------------------------
0xee0000 N 20:00:00:11:0d:97:00:00 scsi-fcp:init
0xee0001 N 20:00:00:11:0d:97:00:01 scsi-fcp:init
0xee0020
0xee0021
N
N
20:01:00:11:0d:97:01:00
20:01:00:11:0d:97:01:01 scsi-fcp:target scsi-fcp:target
0xee0400 N 10:00:00:de:fb:74:e8:31 (Cisco) ipfc
Total number of entries = 5
7.
Verify the pending zone configurations using the autozone --showpending command: switch# autozone --showpending
Feature AutoZone : Enabled zoneset name AUTOZONESET vsan 1 zone name AUTOZONE_JPG21190082_2 vsan 1 member pwwn 20:00:00:11:0d:97:00:01 member pwwn 20:01:00:11:0d:97:01:00 zone name AUTOZONE_JPG21190082_3 vsan 1 member pwwn 20:00:00:11:0d:97:00:00 member pwwn 20:01:00:11:0d:97:01:01 zone name AUTOZONE_JPG21190082_4 vsan 1 member pwwn 20:00:00:11:0d:97:00:01 member pwwn 20:01:00:11:0d:97:01:01
8.
(Optional) You can execute Autozone manually for updating the zoning information each time a new device is logged into the switch using the autozone --update command: switch# autozone --update
Device with pwwn 10:00:00:de:fb:74:e8:31 is not registered with FC4-type Init or Target.
Hence, it will be ignored for AutoZone configuration.
Configuring zones for vsan 1
AUTOZONE_JPG21190082_1
AUTOZONE_JPG21190082_2
AUTOZONE_JPG21190082_3
AUTOZONE_JPG21190082_4
Configuring zoneset for vsan 1
54
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Configuring and Managing Zones
Zone Configuration
Activating the zoneset. Please wait...
Configured zoneset AUTOZONESET for vsan 1 successfully.
9.
Verify the zone configuration for the new devices using the autozone --show command: switch# autozone --show
Feature AutoZone : Enabled
AutoSave Configuration : Enabled
The possible zone/zoneset configuration with AutoZone feature for currently logged-in devices is : zoneset name AUTOZONESET vsan 1 zone name AUTOZONE_JPG21190082_1 vsan 1 member pwwn 20:00:00:11:0d:97:00:00 member pwwn 20:01:00:11:0d:97:01:00 zone name AUTOZONE_JPG21190082_2 vsan 1 member pwwn 20:00:00:11:0d:97:00:01 member pwwn 20:01:00:11:0d:97:01:00 zone name AUTOZONE_JPG21190082_3 vsan 1 member pwwn 20:00:00:11:0d:97:00:00 member pwwn 20:01:00:11:0d:97:01:01 zone name AUTOZONE_JPG21190082_4 vsan 1 member pwwn 20:00:00:11:0d:97:00:01 member pwwn 20:01:00:11:0d:97:01:01
Zone Configuration
About the Edit Local Full Zone Database Tool
Use the Edit Full Zone Database tool to complete the following tasks:
• Displays the information by VSAN, by using the down-down menu without having to get out of the window, selecting a VSAN, and re-entering.
• Move devices up or down by alias or by zone, using the Add to zone or alias button.
• Add zoning characteristics based on the alias in different folders.
• Rename zone sets, zones, or aliases.
The Edit Local Full Zone Database tool allows you to zone across multiple switches and all zoning features are available through the Edit Local Full Zone Database dialog box (see
Figure 11: Edit Local Full Zone
Database Dialog Box, on page 56
).
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
55
Configuring a Zone
Figure 11: Edit Local Full Zone Database Dialog Box
Configuring and Managing Zones
1 You can display information by VSAN by using the drop-down menu without closing the dialog box, selecting a VSAN, and re-entering.
3 You can add zoning characteristics based on alias in different folders.
2 You can use the Add to zone button to move devices up or down by alias or by zone.
4 You can triple-click to rename zone sets, zones, or aliases in the tree.
Note The Device Alias radio button is visible only if device alias is in enhanced mode. For more information, see
Creating Device Aliases, on page 158
section.
Configuring a Zone
Tip Use a relevant display command (for example, show interface or show flogi database ) to obtain the required value in hex format.
Tip Use the show wwn switch command to retrieve the sWWN. If you do not provide a sWWN, the software automatically uses the local sWWN.
56
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Configuring and Managing Zones
Configuring a Zone
Tip Expand Switches from the Physical Attributes pane to retrieve the sWWN. If you do not provide a sWWN, the software automatically uses the local sWWN.
Note Interface-based zoning only works with Cisco MDS 9000 Series switches. Interface-based zoning does not work if interop mode is configured in that VSAN.
When the number of zones configured has exceeded the maximum number of zones allowed across all VSANs, this message is displayed: switch(config)# zone name temp_zone1 vsan 300 cannot create the zone; maximum possible number of zones is already configured
Note For configuration limits on configuring the number of zones, zone members and zone sets, refer to the Cisco
MDS NX-OS Configuration Limits .
To configure a zone and assign a zone name, follow these steps:
Step 1
Step 2
Step 3 switch# configure terminal
Enters configuration mode.
switch(config)# zone name Zone1 vsan 3
Example: switch(config-zone)#
Configures a zone called Zone1 for the VSAN called vsan3.
Note All alphanumeric characters or one of the following symbols ($, -, ^, _) are supported.
switch(config-zone)# member type value
Example: pWWN example:
Example: switch(config-zone)# member pwwn 10:00:00:23:45:67:89:ab
Example:
Fabric pWWN example:
Example: switch(config-zone)# member fwwn 10:01:10:01:10:ab:cd:ef
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
57
Configuring and Managing Zones
Configuring a Zone
Example:
FC ID example:
Example: switch(config-zone)# member fcid 0xce00d1
Example:
FC alias example:
Example: switch(config-zone)# member fcalias Payroll
Example:
Domain ID example:
Example: switch(config-zone)# member domain-id 2 portnumber 23
Example:
IPv4 address example:
Example: switch(config-zone)# member ip-address 10.15.0.0 255.255.0.0
Example:
IPv6 address example:
Example: switch(config-zone)# member ipv6-address 2001::db8:800:200c:417a/64
Example:
Local sWWN interface example:
Example: switch(config-zone)# member interface fc 2/1
Example:
Remote sWWN interface example:
Example: switch(config-zone)# member interface fc2/1 swwn 20:00:00:05:30:00:4a:de
Example:
58
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Configuring and Managing Zones
Configuring a Zone Using the Zone Configuration Tool
Domain ID interface example:
Example: switch(config-zone)# member interface fc2/1 domain-id 25
Example: switch(config-zone)# member symbolic-nodename iqn.test
Configures a member for the specified zone (Zone1) based on the type (pWWN, fabric pWWN, FC ID, fcalias, domain
ID, IPv4 address, IPv6 address, or interface) and value specified.
Caution You must only configure pWWN-type zoning on all MDS switches running Cisco SAN-OS if there is a Cisco
MDS 9020 switch running FabricWare in the same fabric.
Note The Cisco MDS 9396S switch has 96 ports and the other Cisco MDS switches have lower ranges. Therefore while configuring a zone member based on interface type always select a fabric switch which potentially has the highest interface count in the fabric.
Configuring a Zone Using the Zone Configuration Tool
To create a zone and move it into a zone set using DCNM SAN Client, follow these steps:
Step 1 Click the Zone icon in the toolbar (see
Figure 12: Zone Icon, on page 59 ).
Figure 12: Zone Icon
Step 2
You see the Select VSAN dialog box.
Select the VSAN where you want to create a zone and click OK.
switch(config)# callhome
You see the Edit Local Full Zone Database dialog box (see
Figure 13: Edit Local Full Zone Database Dialog Box, on page 60 ).
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
59
Configuring a Zone Using the Zone Configuration Tool
Figure 13: Edit Local Full Zone Database Dialog Box
Configuring and Managing Zones
Step 3
If you want to view zone membership information, right-click in the All Zone Membership(s) column, and then click
Show Details for the current row or all rows from the pop-up menu.
Click Zones in the left pane and click the Insert icon to create a zone.
You see the Create Zone dialog box (see
Figure 14: Create Zone Dialog Box, on page 60 ).
Figure 14: Create Zone Dialog Box
Step 4
Step 5
Step 6
Step 7
Enter a zone name.
Check one of the following check boxes: a. Read Only —The zone permits read and denies write.
b. Permit QoS traffic with Priority —You set the priority from the drop-down menu.
c.
Restrict Broadcast Frames to Zone Members
Click OK to create the zone.
If you want to move this zone into an existing zone set, skip to Step 8.
Click Zoneset in the left pane and click the Insert icon to create a zone set.
60
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Configuring and Managing Zones
You see the Zoneset Name dialog box (see
Figure 15: Zoneset Name Dialog Box, on page 61 ).
Figure 15: Zoneset Name Dialog Box
Adding Zone Members
Step 8
Step 9
Enter a zone set name and click OK .
Note One of these symbols ($, -, ^, _) or all alphanumeric characters are supported. In interop mode 2 and 3, this symbol (_) or all alphanumeric characters are supported.
Select the zone set where you want to add a zone and click the Insert icon or you can drag and drop Zone3 over
Zoneset1.
You see the Select Zone dialog box (see
Figure 16: Select Zone Dialog Box, on page 61
).
Figure 16: Select Zone Dialog Box
Step 10 Click Add to add the zone.
Adding Zone Members
Once you create a zone, you can add members to the zone. You can add members using multiple port identification types.
To add a member to a zone using DCNM SAN Client, follow these steps:
Step 1
Step 2
Choose Zone > Edit Local Full Zone Database .
You see the Select VSAN dialog box.
Select a VSAN and click OK .
You see the Edit Local Full Zone Database dialog box for the selected VSAN.
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
61
Adding Zone Members
Figure 17: Edit Local Full Zone Database Dialog Box
Configuring and Managing Zones
Step 3 Select the members you want to add from the Fabric pane (see
Figure 17: Edit Local Full Zone Database Dialog Box, on page 62
) and click Add to Zone or click the zone where you want to add members and click the Insert icon.
You see the Add Member to Zone dialog box (see
Figure 18: Add Member to Zone Dialog Box, on page 62
).
Figure 18: Add Member to Zone Dialog Box
Step 4
Step 5
Note The Device Alias radio button is visible only if device alias is in enhanced mode. For more information, see
section.
Click the browse button and select a port name or check the LUN check box and click the browse button to configure
LUNs.
Click Add to add the member to the zone.
62
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Configuring and Managing Zones
Filtering End Devices Based on Name, WWN or FC ID
Note When configuring a zone member, you can specify that a single LUN has multiple IDs depending on the operating system. You can select from six different operating systems
Filtering End Devices Based on Name, WWN or FC ID
To filter the end devices and device aliases, follow these steps:
Step 1
Step 2
Step 3
Step 4
Click the Zone icon in the toolbar (see
Figure 12: Zone Icon, on page 59 ).
Select Name, WWN or FC ID from the With drop-down list.
Enter a filter condition, such as *zo1*, in the Filter text box.
Click Go .
Adding Multiple End Devices to Multiple Zones
To add multiple end devices to multiple zones, follow these steps:
Step 1
Step 2
Step 3
Step 4
Step 5
Click the Zone icon in the toolbar (see
Figure 12: Zone Icon, on page 59 ).
Use the Ctrl key to select multiple end devices.
Right-click and then select Add to Zone .
Use the Ctrl key to select multiple zones from the pop-up window displayed.
Click Add .
Selected end devices are added to the selected zones.
Zone Sets and FC Aliases
Zones provide a method for specifying access control, while zone sets are a grouping of zones to enforce access control in the fabric.
Zone sets are configured with the names of the member zones and the VSAN (if the zoneset is in a configured
VSAN).
Zoneset Distribution —You can distribute full zone sets using one of two methods: one-time distribution or full zoneset distribution.
Zoneset Duplication —You can make a copy of a zoneset and then edit it without altering the original zoneset.
You can copy an active zoneset from the bootflash: directory, volatile: directory, or slot0, to one of the following areas:
• To the full zoneset
• To a remote location (using FTP, SCP, SFTP, or TFTP)
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
63
Configuring and Managing Zones
ZoneSet Creation
The active zoneset is not part of the full zoneset. You cannot make changes to an existing zoneset and activate it, if the full zoneset is lost or is not propagated.
ZoneSet Creation
In the figure, two separate sets are created, each with its own membership hierarchy and zone members.
Either zoneset A or zoneset B can be activated (but not together).
Tip Zonesets are configured with the names of the member zones and the VSAN (if the zoneset is in a configured
VSAN).
Activating a Zoneset
Changes to a zoneset do not take effect in a full zoneset until you activate it.
Tip You do not have to issue the copy running-config startup-config command to store the active zoneset.
However, you need to issue the copy running-config startup-config command to explicitly store full zone sets. If there is more than one switch in a fabric, the copy running-config startup-config fabric command should be issued. The fabric keyword causes the copy running-config startup-config command to be issued on all the switches in the fabric, and also saves the full zone information to the startup-config on all the switches in the fabric. This is important in the event of a switch reload or power cycle.
To activate or deactivate an existing zoneset, follow these steps:
Step 1
Step 2 switch# config terminal
Example: switch(config)#
Enters configuration mode.
switch(config)# zoneset activate name Zoneset1 vsan 3
Activates the specified zoneset.
If full zoneset distribution is configured for a VSAN, the zoneset activation also distributes the full zoning database to the other switches in the fabric.
If enhanced zoning is configured for a VSAN then the zoneset activation is held pending until the zone commit vsan vsan-id command is enabled. The show zone pending-diff vsan vsan-id displays the pending changes.
Note While activating a zoneset, if the zoneset overwrite-control vsan id command is enabled and the zoneset name is different from the current active zoneset, the activation will fail with an error message. For more information see
Overwrite Control for an Active Zoneset, on page 67 .
switch(config)# zoneset activate name Zoneset2 vsan 3
64
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Configuring and Managing Zones
Activating a Zoneset Using DCNM SAN Client
Step 3
WARNING: You are trying to activate zoneset2, which is different from current active zoneset1. Do you want to continue? (y/n) [n] y switch(config)# no zoneset activate name Zoneset1 vsan 3
Deactivates the specified zoneset.
Activating a Zoneset Using DCNM SAN Client
To activate an existing zone set using DCNM SAN Client, follow these steps:
Step 1
Step 2
Step 3
Choose Zone > Edit Local Full Zone Database .
You see the Select VSAN dialog box.
Select a VSAN and click OK .
You see the Edit Local Full Zone Database dialog box for the selected VSAN.
Click Activate to activate the zone set.
You see the pre-activation check dialog box (see
Figure 19: Pre-Activation Check Dialog Box, on page 65
).
Figure 19: Pre-Activation Check Dialog Box
Step 4 Click Yes to review the differences.
You see the Local vs. Active Differences dialog box (see
Figure 20: Local vs Active Differences Dialog Box, on page
Figure 20: Local vs Active Differences Dialog Box
Step 5 Click Close to close the dialog box.
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
65
Configuring and Managing Zones
Deactivating a Zoneset
You see the Save Configuration dialog box (see
Figure 21: Save Configuration Dialog Box, on page 66
).
Figure 21: Save Configuration Dialog Box
Step 6
Step 7
Check the Save Running to Startup Configuration check box to save all changes to the startup configuration.
Click Continue Activation to activate the zone set, or click Cancel to close the dialog box and discard any unsaved changes.
You see the Zone Log dialog box, which shows if the zone set activation was successful (see
).
Figure 22: Zone Log Dialog Box
Deactivating a Zoneset
To deactivate an existing zone set, follow these steps:
Step 1 Right-click the zone set you want to deactivate and then click Deactivate from the pop-up menu.
66
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Configuring and Managing Zones
Displaying Zone Membership Information
Step 2
Step 3
You see the Deactivate Zoneset dialog box.
Enter deactivate in the text box and then click OK .
You see the Input dialog box.
Enter deactivate in the text box and then click OK to deactivate the zone set.
Note To enable this option, you need to modify the server.properties file.
Displaying Zone Membership Information
To display zone membership information for members assigned to zones in DCNM SAN Client, follow these steps:
Step 1
Step 2
Step 3
Choose Zone > Edit Local Full Zone Database .
You see the Select VSAN dialog box.
Select a VSAN and click OK .
You see the Edit Local Full Zone Database dialog box for the selected VSAN.
Click Zones in the left pane. The right pane lists the members for each zone.
Note The default zone members are explicitly listed only when the default zone policy is configured as permit . When the default zone policy is configured as deny , the members of this zone are not shown. See the
Tip You do not have to issue the copy running-config startup-config command to store the active zoneset.
However, you need to issue the copy running-config startup-config command to explicitly store full zone sets. If there is more than one switch in a fabric, the copy running-config startup-config fabric command should be issued. The fabric keyword causes the copy running-config startup-config command to be issued on all the switches in the fabric, and also saves the full zone information to the startup-config on all the switches in the fabric. This is important in the event of a switch reload or power cycle.
Overwrite Control for an Active Zoneset
When activating a new zoneset, if users make a mistake while entering the zoneset name, and if this name already exists on the switch, it results in activation of the wrong zoneset and traffic loss. To avoid activating a wrong zoneset, the zoneset overwrite-control vsan id command is introduced.
Note Even when the zoneset overwrite-control vsan id command is enabled, the user can override it and continue with the activation of a new zoneset using the zoneset activate name zoneset name vsan vsan -id force command.
Step 1 switch# configure terminal
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
67
Configuring and Managing Zones
Default Zone
Step 2
Step 3
Example: switch(config)#
Enters configuration mode.
switch(config)# zoneset overwrite-control vsan 3
Enables overwrite-control for the specified VSAN.
switch(config)# zoneset overwrite-control vsan 1
WARNING: This will enable Activation Overwrite control. Do you want to continue?
(y/n) [n]
Note The zoneset overwrite-control vsan id command can be enabled only in enhanced zone mode.
switch(config)# show zone status vsan 3
Displays the status of the VSAN, if overwrite-control is enabled or not.
What to do next
Displaying Zone Status switch(config)# show zone status vsan 3
VSAN: 2 default-zone: deny distribute: full Interop: default mode: enhanced merge-control: allow session: none hard-zoning: enabled broadcast: unsupported smart-zoning: disabled rscn-format: fabric-address activation overwrite control: enabled
Default zone: qos: none broadcast: unsupported ronly: unsupported
Full Zoning Database :
DB size: 348 bytes
Zonesets:2 Zones:2 Aliases: 0 Attribute-groups: 1
Active Zoning Database :
DB size: 68 bytes
Name: hellset Zonesets:1 Zones:1
Current Total Zone DB Usage: 416 / 2097152 bytes (0 % used)
Pending (Session) DB size:
Full DB Copy size: 0 bytes
Active DB Copy size: 0 bytes
SFC size: 0 / 2097152 bytes (0 % used)
Status: Commit completed at 15:19:49 UTC Jun 11 2015
Default Zone
Each member of a fabric (in effect a device attached to an Nx port) can belong to any zone. If a member is not part of any active zone, it is considered to be part of the default zone. Therefore, if no zoneset is active in the fabric, all devices are considered to be in the default zone. Even though a member can belong to multiple zones, a member that is part of the default zone cannot be part of any other zone. The switch determines whether a port is a member of the default zone when the attached port comes up.
68
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Configuring and Managing Zones
Configuring the Default Zone Access Permission
Note Unlike configured zones, default zone information is not distributed to the other switches in the fabric.
Traffic can either be permitted or denied among members of the default zone. This information is not distributed to all switches; it must be configured in each switch.
Note When the switch is initialized for the first time, no zones are configured and all members are considered to be part of the default zone. Members are not permitted to talk to each other.
Configure the default zone policy on each switch in the fabric. If you change the default zone policy on one switch in a fabric, be sure to change it on all the other switches in the fabric.
Note The default settings for default zone configurations can be changed.
The default zone members are explicitly listed when the default policy is configured as permit or when a zoneset is active. When the default policy is configured as deny, the members of this zone are not explicitly enumerated when you issue the show zoneset active command.
Note The current default zoning policy is deny. The hidden active zoneset is d__efault__cfg in MDS. When there is a mismatch in default-zoning policies between two switches (permit on one side and deny on the other), zone merge will fail. The behavior is the same between two Brocade switches as well. The error messages will be as shown below.
The error messages will be as shown below:
Switch1 syslog: switch(config-if)# 2014 Sep 2 06:33:21 hac15 %ZONE-2-ZS_MERGE_FAILED: %$VSAN 1%$ Zone merge failure, isolating interface fc2/10 received reason: Default zoning policy conflict. Received rjt from adjacent switch:[reason:0]
Switch2 syslog: switch(config-if)# 2014 Sep 2 12:13:17 hac16 %ZONE-2-ZS_MERGE_FAILED: %$VSAN 1%$ Zone merge failure, isolating interface fc3/10 reason: Default zoning policy conflict.:[reason:0]
You can change the default zone policy for any VSAN by choosing VSANxx > Default Zone from the DCNM
SAN Client menu tree and clicking the Policies tab. It is recommended that you establish connectivity among devices by assigning them to a non-default zone.
Configuring the Default Zone Access Permission
To permit or deny traffic to members in the default zone, follow these steps:
Step 1 switch# configure terminal
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
69
Configuring and Managing Zones
Configuring the Default Zone Access Permission Using DCNM SAN Client
Step 2
Step 3
Enters configuration mode.
switch(config)# zone default-zone permit vsan 1
Permits traffic flow to default zone members.
switch(config)# no zone default-zone permit vsan 1
Denies (default) traffic flow to default zone members.
Configuring the Default Zone Access Permission Using DCNM SAN Client
To permit or deny traffic to members in the default zone using DCNM SAN Client, follow these steps:
Step 1
Step 2
Expand a VSAN and then select Default Zone in the DCNM SAN Client Logical Domains pane.
Click the Policies tab in the Information pane.
You see the zone policies information in the Information pane (see
Figure 23: Default Zone Policies, on page 70
).
Figure 23: Default Zone Policies
Step 3
The active zone set is shown in italic type. After you make changes to the active zone set and before you activate the changes, the zone set is shown in boldface italic type.
In the Default Zone Behaviour field, choose either permit or deny from the drop-down menu.
About FC Alias Creation
While the pWWN, fWWN, and so on of an end node or fabric port have to be specified to configure different features on a Cisco MDS switch, you must ensure to assign the correct value. An incorrect value, derived from a typo for example, may cause unexpected results. You can avoid this if you define a user-friendly name and use this name in all of the configuration commands, as required. These user-friendly names are referred to as FC aliases and they are defined according to naming conventions that are specific to each and every organization.
FC aliases are stored within the zone server database and the NX-OS software automatically converts FC aliases into their corresponding zone member types. A device alias name is a different type of alias and is described in the
Distributing Device Alias Services, on page 151
chapter. Device aliases can be assigned to
FC aliases, but not vice-versa.
70
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Configuring and Managing Zones
Creating FC Aliases
FC aliases are case sensitive and restricted to 64 alphanumeric characters. An FC alias name may include one or more of the following characters:
• a to z and A to Z
• 1 to 9
• - (hyphen) and _ (underscore)
• $ (dollar sign) and ^ (up caret)
You can assign an FC alias name and configure an FC alias member using the following values:
• pWWN—The WWN of the N or NL port is in hex format (for example, 10:00:00:23:45:67:89:ab).
• fWWN—The WWN of the fabric port name is in hex format (for example, 10:00:00:23:45:67:89:ab).
• FC ID—The N port ID is in 0xhhhhhh format (for example, 0xce00d1).
• Domain ID—The domain ID is an integer from 1 to 239. A mandatory port number of a non-Cisco switch is required to complete this membership configuration.
• IPv4 address—The IPv4 address of an attached device is in 32 bits in dotted decimal format along with an optional subnet mask. If a mask is specified, any device within the subnet becomes a member of the specified zone.
• IPv6 address—The IPv6 address of an attached device is in 128 bits in colon- (:) separated) hexadecimal format.
• Interface—Interface-based zoning is similar to port-based zoning because the switch interface is used to configure the zone. You can specify a switch interface as a zone member for both local and remote switches. To specify a remote switch, enter the remote switch WWN (sWWN) or the domain ID in the particular VSAN.
• Device Alias—A device alias name is a different type of alias and it can be assigned as a member to a
FC alias.
Tip The Cisco NX-OS software supports a maximum of 2048 aliases per VSAN.
Creating FC Aliases
To create an alias, follow these steps:
Step 1
Step 2 switch# configure terminal
Enters configuration mode.
switch(config)# fcalias name AliasSample vsan 3 switch(config-fcalias)#
Configures an alias name (AliasSample).
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
71
Configuring and Managing Zones
Creating FC Aliases Using DCNM SAN Client
Step 3
Step 4 switch(config-fcalias)# member type value
Configures a member for the specified fcalias (AliasSample) based on the type and value specified
(pWWN, fabric pWWN, FC ID, domain ID, IPv4 address, IPv6 address, or interface).
Multiple members can be inserted for a single FC alias on multiple lines: switch(config-fcalias)# member pwwn 10:00:00:23:45:67:89:ab switch(config-fcalias)# switch(config-fcalias)# member fwwn 10:01:10:01:10:ab:cd:ef member fcid 0x222222 pWWN example: switch(config-fcalias)# member pwwn 10:00:00:23:45:67:89:ab fWWN example: switch(config-fcalias)# member fwwn 10:01:10:01:10:ab:cd:ef
FC ID example: switch(config-fcalias)# member fcid 0x222222
Domain ID example: switch(config-fcalias)# member domain-id 2 portnumber 23
IPv4 address example: switch(config-fcalias)# member ip-address 10.15.0.0 255.255.0.0
IPv6 address example: switch(config-fcalias)# member ipv6-address 2001::db8:800:200c:417a/64
Local sWWN interface example: switch(config-fcalias)# member interface fc 2/1
Remote sWWN interface example: switch(config-fcalias)# member interface fc2/1 swwn 20:00:00:05:30:00:4a:de
Domain ID interface example: switch(config-fcalias)# member interface fc2/1 domain-id 25 switch(config-fcalias)# zone commit vsan id
Commits the changes made to the specified VSAN.
Creating FC Aliases Using DCNM SAN Client
To create an FC alias using DCNM SAN Client, follow these steps:
Step 1
Step 2
Choose Zone > Edit Local Full Zone Database .
You see the Select VSAN dialog box.
Select a VSAN and click OK .
You see the Edit Local Full Zone Database dialog box for the selected VSAN.
72
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Configuring and Managing Zones
Adding Members to Aliases
Step 3 Click Aliases in the lower left pane (see
Figure 24: Creating an FC Alias, on page 73
). The right pane lists the existing aliases.
Figure 24: Creating an FC Alias
Step 4 Click the Insert icon to create an alias.
You see the Create Alias dialog box (see
Figure 25: Create Alias Dialog Box, on page 73 ).
Figure 25: Create Alias Dialog Box
Step 5
Step 6
Set the Alias Name and the pWWN.
Click OK to create the alias.
Adding Members to Aliases
To add a member to an alias using DCNM SAN Client, follow these steps:
Step 1
Step 2
Choose Zone > Edit Local Full Zone Database .
You see the Select VSAN dialog box.
Select a VSAN and click OK .
You see the Edit Local Full Zone Database dialog box for the selected VSAN (see
Figure 26: Edit Local Full Zone
Database Dialog Box, on page 74
).
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
73
Adding Members to Aliases
Figure 26: Edit Local Full Zone Database Dialog Box
Configuring and Managing Zones
Step 3 Select the member(s) you want to add from the Fabric pane (see
Figure 26: Edit Local Full Zone Database Dialog Box, on page 74 ) and click
Add to Alias or click the alias where you want to add members and click the Insert icon.
You see the Add Member to Alias dialog box (see
Figure 27: Add Member to Alias Dialog Box, on page 74 ).
Figure 27: Add Member to Alias Dialog Box
Note The Device Alias radio button is visible only if device alias is in enhanced mode. For more information, see
Creating Device Aliases, on page 158
section.
74
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Configuring and Managing Zones
Converting Zone Members to pWWN-Based Members
Step 4
Step 5
Click the browse button and select a port name or check the LUN check box and click the browse button to configure
LUNs.
Click Add to add the member to the alias.
Converting Zone Members to pWWN-Based Members
You can convert zone and alias members from switch port or FC ID based membership to pWWN-based membership. You can use this feature to convert to pWWN so that your zone configuration does not change if a card or switch is changed in your fabric.
To convert switch port and FC ID members to pWWN members using DCNM SAN Client, follow these steps:
Step 1
Step 2
Step 3
Step 4
Step 5
Step 6
Choose Zone > Edit Local Full Zone Database .
You see the Select VSAN dialog box.
Select a VSAN and click OK .
You see the Edit Local Full Zone Database dialog box for the selected VSAN.
Click the zone you want to convert.
Choose Tools > Convert Switch Port/FCID members to By pWWN .
You see the conversion dialog box, listing all members that will be converted.
Verify the changes and click Continue Conversion .
Click Yes in the confirmation dialog box to convert that member to pWWN-based membership.
Creating Zone Sets and Adding Member Zones
Tip You do not have to issue the copy running-config startup-config command to store the active zoneset.
However, you need to issue the copy running-config startup-config command to explicitly store full zone sets. If there is more than one switch in a fabric, the copy running-config startup-config fabric command should be issued. The fabric keyword causes the copy running-config startup-config command to be issued on all the switches in the fabric, and also saves the full zone information to the startup-config on all the switches in the fabric. This is important in the event of a switch reload or power cycle.
Caution If you deactivate the active zoneset in a VSAN that is also configured for IVR, the active IVR zoneset (IVZS) is also deactivated and all IVR traffic to and from the switch is stopped. This deactivation can disrupt traffic in more than one VSAN. Before deactivating the active zoneset, check the active zone analysis for the VSAN
(see the
Zone and ZoneSet Analysis, on page 130 ). To reactivate the IVZS, you must reactivate the regular
zoneset (refer to the Cisco MDS 9000 Series NX-OS Inter-VSAN Routing Configuration Guide ).
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
75
Configuring and Managing Zones
Creating Zone Sets and Adding Member Zones
Caution If the currently active zoneset contains IVR zones, activating the zoneset from a switch where IVR is not enabled disrupts IVR traffic to and from that VSAN. We strongly recommend that you always activate the zoneset from an IVR-enabled switch to avoid disrupting IVR traffic.
Note The pWWN of the virtual target does not appear in the zoning end devices database in DCNM SAN Client.
If you want to zone the virtual device with a pWWN, you must enter it in the Add Member to Zone dialog box when creating a zone. However, if the device alias is in enhanced mode, the virtual device names appear in the device alias database in the DCNM SAN Client zoning window. In this case, users can choose to select either the device alias name or enter the pWWN in the Add Member to Zone dialog box.
For more information, see the
Adding Zone Members, on page 61
section.
To create a zoneset to include several zones, follow these steps:
Step 1
Step 2
Step 3
Step 4
Step 5 switch# configure terminal
Enters configuration mode.
switch(config)# zoneset name Zoneset1 vsan 3
Example: switch(config-zoneset)#
Configures a zoneset called Zoneset1.
Tip To activate a zoneset, you must first create the zone and a zoneset.
switch(config-zoneset)# member Zone1
Adds Zone1 as a member of the specified zoneset (Zoneset1).
Tip If the specified zone name was not previously configured, this command will return the Zone not present error message.
switch(config-zoneset)# zone name InlineZone1
Example: switch(config-zoneset-zone)#
Adds a zone (InlineZone1) to the specified zoneset (Zoneset1).
Tip Execute this step only if you need to create a zone from a zoneset prompt.
switch(config-zoneset-zone)# member fcid 0x111112
Example: switch(config-zoneset-zone)#
Adds a new member (FC ID 0x111112) to the new zone (InlineZone1).
76
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Configuring and Managing Zones
Filtering Zones, Zone Sets, and Device Aliases Based on Name
Tip Execute this step only if you need to add a member to a zone from a zoneset prompt.
Filtering Zones, Zone Sets, and Device Aliases Based on Name
To filter the zones, zone sets or device aliases, follow these steps:
Step 1
Step 2
Step 3
Click the Zone icon in the toolbar (see
Figure 12: Zone Icon, on page 59 ).
Enter a filter condition, such as *zo1*, in the Filter text box.
Click Go .
Adding Multiple Zones to Multiple Zone Sets
To add multiple zones to multiple zone sets, follow these steps:
Step 1
Step 2
Step 3
Step 4
Step 5
Step 6
Click the Zone icon in the toolbar (see
Figure 12: Zone Icon, on page 59 ).
From the tree view, select Zoneset .
Use the Ctrl key to select multiple end devices.
Right-click and then select Add to Zoneset .
Use the Ctrl key to select multiple zones from the pop-up window displayed.
Click Add .
Selected zones are added to the selected zone sets.
Zone Enforcement
Zoning can be enforced in two ways: soft and hard. Each end device (N port or NL port) discovers other devices in the fabric by querying the name server. When a device logs in to the name server, the name server returns the list of other devices that can be accessed by the querying device. If an Nx port does not know about the FCIDs of other devices outside its zone, it cannot access those devices.
In soft zoning, zoning restrictions are applied only during interaction between the name server and the end device. If an end device somehow knows the FCID of a device outside its zone, it can access that device.
Hard zoning is enforced by the hardware on each frame sent by an Nx port. As frames enter the switch, source-destination IDs are compared with permitted combinations to allow the frame at wirespeed. Hard zoning is applied to all forms of zoning.
Note Hard zoning enforces zoning restrictions on every frame, and prevents unauthorized access.
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
77
Configuring and Managing Zones
ZoneSet Distribution
Switches in the Cisco MDS 9000 Series support both hard and soft zoning.
ZoneSet Distribution
You can distribute full zone sets using one of two methods: one-time distribution at the EXEC mode level or full zoneset distribution at the configuration mode level.
You can distribute full zone sets using one of two methods: one-time distribution or full zone set distribution.
Table 6: Zone Set Distribution zoneset distribution Command Differences , on page 78
lists the differences between these distribution methods.
Table 6: Zone Set Distribution zoneset distribution Command Differences
One-Time Distribution zoneset distribute vsan
Command (EXEC Mode)
Distributes the full zoneset immediately.
Does not distribute the full zoneset information along with the active zoneset during activation, deactivation, or merge process.
Full Zone Set Distribution zoneset distribute full vsan
Command (Configuration Mode)
Does not distribute the full zoneset immediately.
Remembers to distribute the full zoneset information along with the active zoneset during activation, deactivation, and merge processes.
Tip You do not have to issue the copy running-config startup-config command to store the active zoneset.
However, you need to issue the copy running-config startup-config command to explicitly store full zone sets. If there is more than one switch in a fabric, the copy running-config startup-config fabric command should be issued. The fabric keyword causes the copy running-config startup-config command to be issued on all the switches in the fabric, and also saves the full zone information to the startup-config on all the switches in the fabric. This is important in the event of a switch reload or power cycle.
Enabling Full Zoneset Distribution
All switches in the Cisco MDS 9000 Series distribute active zone sets when new E port links come up or when a new zoneset is activated in a VSAN. The zoneset distribution takes effect while sending merge requests to the adjacent switch or while activating a zoneset.
To enable full zoneset and active zoneset distribution to all switches on a per VSAN basis, follow these steps:
Step 1
Step 2 switch# configure terminal
Enters configuration mode.
switch(config)# zoneset distribute full vsan 33
Enables sending a full zoneset along with an active zoneset.
78
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Configuring and Managing Zones
Enabling Full Zoneset Distribution Using DCNM SAN Client
Enabling Full Zoneset Distribution Using DCNM SAN Client
To enable full zone set and active zone set distribution to all switches on a per VSAN basis using DCNM
SAN Client, follow these steps:
Step 1
Step 2
Expand a VSAN and select a zone set in the Logical Domains pane.
You see the zone set configuration in the Information pane. The Active Zones tab is the default.
Click the Policies tab.
You see the configured policies for the zone (see
Figure 28: Configured Policies for the Zone, on page 79
).
Figure 28: Configured Policies for the Zone
Step 3
Step 4
In the Propagation column, choose fullZoneset from the drop-down menu.
Click Apply Changes to propagate the full zone set.
Enabling a One-Time Distribution
Use the zoneset distribute vsan vsan-id command in EXEC mode to perform this distribution.
switch# zoneset distribute vsan 2
Zoneset distribution initiated. check zone status
This procedure command only distributes the full zoneset information; it does not save the information to the startup configuration. You must explicitly save the running configuration to the startup configuration issue the copy running-config startup-config command to save the full zoneset information to the startup configuration.
Note The zoneset distribute vsan vsan-id commandone-time distribution of the full zone set is supported in interop
2 and interop 3 modes, not in interop 1 mode.
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
79
Configuring and Managing Zones
Enabling a One-Time Distribution Using DCNM SAN Client
Use the show zone status vsan vsan-id command to check the status of the one-time zoneset distribution request.
switch# show zone status vsan 9
VSAN: 9 default-zone: deny distribute: full Interop: default mode: enhanced merge-control: allow session: none hard-zoning: enabled broadcast: enabled smart-zoning: disabled rscn-format: fabric-address activation overwrite control:disabled
Default zone: qos: none broadcast: disabled ronly: disabled
Full Zoning Database :
DB size: 2002584 bytes
Zonesets:4 Zones:7004 Aliases: 0 Attribute-groups: 1
Active Zoning Database :
DB size: 94340 bytes
Name: zoneset-hac13-200 Zonesets:1 Zones:176
Current Total Zone DB Usage: 2096924 / 2097152 bytes (99 % used)
Pending (Session) DB size:
Full DB Copy size: 0 bytes
Active DB Copy size: 0 bytes
SFC size: 0 / 2097152 bytes (0 % used)
Status: Activation completed at 17:28:04 UTC Jun 16 2014
Enabling a One-Time Distribution Using DCNM SAN Client
You can perform a one-time distribution of inactive, unmodified zone sets throughout the fabric. To propagate a one-time distribution of the full zone set using DCNM SAN Client, follow these steps:
Step 1
Step 2
Step 3
Choose Zone > Edit Local Full Zone Database .
You see the Edit Local Full Zone Database dialog box.
Click the appropriate zone from the list in the left pane.
Click Distribute to distribute the full zone set across the fabric.
About Recovering from Link Isolation
When two switches in a fabric are merged using a TE or E port, these TE and E ports may become isolated when the active zoneset databases are different between the two switches or fabrics. When a TE port or an E port become isolated, you can recover that port from its isolated state using one of three options:
• Import the neighboring switch's active zoneset database and replace the current active zoneset (see
29: Importing and Exporting the Database , on page 81 .
• Export the current database to the neighboring switch.
• Manually resolve the conflict by editing the full zoneset, activating the corrected zoneset, and then bringing up the link.
80
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Configuring and Managing Zones
Figure 29: Importing and Exporting the Database
Importing and Exporting Zone Sets
Importing and Exporting Zone Sets
Note Issue the import and export commands from a single switch. Importing from one switch and exporting from another switch can lead to isolation again.
To import or export the zoneset information from or to an adjacent switch, follow these steps:
Step 1
Step 2
Step 3
Step 4 switch# zoneset import interface fc1/3 vsan 2
Imports the zoneset from the adjacent switch connected through the fc 1/3 interface for VSAN 2.
switch# zoneset import interface fc1/3 vsan 2-5
Imports the zoneset from the adjacent switch connected through the fc 1/3 interface for VSANs ranging from 2 through
5.
switch# zoneset export vsan 5
Exports the zoneset to the adjacent switch connected through VSAN 5.
switch# zoneset export vsan 5-8
Exports the zoneset to the adjacent switch connected through the range of VSANs 5 through 8.
Importing and Exporting Zone Sets Using DCNM SAN Client
To import or export the zone set information from or to an adjacent switch using DCNM SAN Client, follow these steps:
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
81
Configuring and Managing Zones
Zoneset Duplication
Step 1 Choose Tools > Zone Merge Fail Recovery .
You see the Zone Merge Failure Recovery dialog box (see
Figure 30: Zone Merge Failure Recovery Dialog Box, on page
).
Figure 30: Zone Merge Failure Recovery Dialog Box
Step 2
Step 3
Step 4
Step 5
Step 6
Click the Import Active Zoneset or the Export Active Zoneset radio button.
Select the switch from which to import or export the zone set information from the drop-down list.
Select the VSAN from which to import or export the zone set information from the drop-down list.
Select the interface to use for the import process.
Click OK to import or export the active zone set.
Issue the import and export commands from a single switch. Importing from one switch and exporting from another switch can lead to isolation again.
Zoneset Duplication
You can make a copy and then edit it without altering the existing active zoneset. You can copy an active zoneset from the bootflash: directory, volatile: directory, or slot0, to one of the following areas:
• To the full zoneset
• To a remote location (using FTP, SCP, SFTP, or TFTP)
The active zoneset is not part of the full zoneset. You cannot make changes to an existing zoneset and activate it, if the full zoneset is lost or is not propagated.
Caution Copying an active zoneset to a full zoneset may overwrite a zone with the same name, if it already exists in the full zoneset database.
82
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Configuring and Managing Zones
Copying Zone Sets
Copying Zone Sets
On the Cisco MDS Series switches, you cannot edit an active zoneset. However, you can copy an active zoneset to create a new zoneset that you can edit.
Caution If the Inter-VSAN Routing (IVR) feature is enabled and if IVR zones exist in the active zoneset, then a zoneset copy operation copies all the IVR zones to the full zone database. To prevent copying to the IVR zones, you must explicitly remove them from the full zoneset database before performing the copy operation. For more information on the IVR feature see the Cisco MDS 9000 Series NX-OS Inter-VSAN Routing Configuration
Guide .
To make a copy of a zoneset, follow this step:
Step 1
Step 2 switch# zone copy active-zoneset full-zoneset vsan 2
Example:
Please enter yes to proceed.(y/n) [n]?
y
Makes a copy of the active zoneset in VSAN 2 to the full zoneset.
switch# zone copy vsan 3 active-zoneset scp://guest@myserver/tmp/active_zoneset.txt
Copies the active zone in VSAN 3 to a remote location using SCP.
Copying Zone Sets Using DCNM SAN Client
To make a copy of a zone set using DCNM SAN Client, follow these steps:
Step 1 Choose Edit > Copy Full Zone Database .
You see the Copy Full Zone Database dialog box (see
Figure 31: Copy Full Zone Database Dialog Box, on page 83
).
Figure 31: Copy Full Zone Database Dialog Box
Step 2 Click the Active or the Full radio button, depending on which type of database you want to copy.
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
83
Configuring and Managing Zones
About Backing Up and Restoring Zones
Step 3
Step 4
Step 5
Step 6
Select the source VSAN from the drop-down list.
If you selected Copy Full , select the source switch and the destination VSAN from those drop-down lists.
Select the destination switch from the drop-down list.
Click Copy to copy the database.
About Backing Up and Restoring Zones
You can back up the zone configuration to a workstation using TFTP. This zone backup file can then be used to restore the zone configuration on a switch. Restoring the zone configuration overwrites any existing zone configuration on a switch.
Backing Up Zones Using DCNM SAN Client
To back up the full zone configuration using DCNM SAN Client, follow these steps:
Step 1
Step 2
Choose Zone > Edit Local Full Zone Database . You see the Select VSAN dialog box.
Select a VSAN and click OK . You see the Edit Local Full Zone Database dialog box for the selected VSAN (see
32: Edit Local Full Zone Database, on page 84
).
Figure 32: Edit Local Full Zone Database
Step 3 Choose File > Backup > This VSAN Zones to back up the existing zone configuration to a workstation using TFTP,
SFTP, SCP, or FTP. You see the Backup Zone Configuration dialog box (see
Figure 33: Backup Zone Configuration
84
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Configuring and Managing Zones
Figure 33: Backup Zone Configuration Dialog Box
Restoring Zones
Step 4
Step 5
You can edit this configuration before backing up the data to a remote server.
Provide the following Remote Options information to back up data onto a remote server: a) Using —Select the protocol.
b) Server IP Address —Enter the IP adress of the server.
c) UserName —Enter the name of the user.
d) Password —Enter the password for the user.
e) File Name(Root Path) —Enter the path and the filename.
Click Backup or click Cancel to close the dialog box without backing up.
Restoring Zones
To restore the full zone configuration using DCNM SAN Client, follow these steps:
Step 1
Step 2
Choose Zone > Edit Local Full Zone Database . You see the Select VSAN dialog box.
Select a VSAN and click OK . You see the Edit Local Full Zone Database dialog box for the selected VSAN (see
34: Edit Local Full Zone Database, on page 86 ).
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
85
Configuring and Managing Zones
Restoring Zones
Figure 34: Edit Local Full Zone Database
Step 3 Choose File > Restore to restore a saved zone configuration using TFTP, SFTP, SCP or FTP. You see the Restore Zone
Configuration dialog box (see
Figure 35: Restore Zone Configuration Dialog Box, on page 86 ).
Figure 35: Restore Zone Configuration Dialog Box
Step 4
Step 5
You can edit this configuration before restoring it to the switch.
Provide the following Remote Options information to restore data from a remote server: a) Using —Select the protocol.
b) Server IP Address —Enter the IP address of the server.
c) UserName —Enter the name of the user.
d) Password —Enter the password for the user.
e) File Name —Enter the path and the filename.
Click Restore to continue or click Cancel to close the dialog box without restoring.
86
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Configuring and Managing Zones
Renaming Zones, Zone Sets, and Aliases
Note
Note
Click View Config to see information on how the zone configuration file from a remote server will be restored.
When you click Yes in this dialog box, you will be presented with the CLI commands that are executed. To close the dialog box, click Close .
Backup and Restore options are available to switches that run Cisco NX-OS Release 4.1(3a) or later.
Renaming Zones, Zone Sets, and Aliases
Note Backup option is available to switches that run Cisco NX-OS Release 4.1(3) or later. Restore option is only supported on Cisco DCNM SAN Client Release 4.1(3) or later.
To rename a zone, zone set, fcalias, or zone-attribute-group, follow these steps:
Step 1
Step 2
Step 3
Step 4
Step 5
Step 6 switch# configure terminal
Enters configuration mode.
switch(config)# zoneset rename oldname newname vsan 2
Renames a zone set in the specified VSAN.
switch(config)# zone rename oldname newname vsan 2
Renames a zone in the specified VSAN.
switch(config)# fcalias rename oldname newname vsan 2
Renames a fcalias in the specified VSAN.
switch(config)# zone-attribute-group rename oldname newname vsan 2
Renames a zone attribute group in the specified VSAN.
switch(config)# zoneset activate name newname vsan 2
Activates the zone set and updates the new zone name in the active zone set.
Renaming Zones, Zone Sets, and Aliases Using DCNM SAN Client
To rename a zone, zone set, or alias using DCNM SAN Client, follow these steps:
Step 1
Step 2
Choose Zone > Edit Local Full Zone Database .
You see the Select VSAN dialog box.
Select a VSAN and click OK .
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
87
Configuring and Managing Zones
Cloning Zones, Zone Sets, FC Aliases, and Zone Attribute Groups
You see the Edit Local Full Zone Database dialog box for the selected VSAN (see
Figure 36: Edit Local Full Zone
Database Dialog Box, on page 88
).
Figure 36: Edit Local Full Zone Database Dialog Box
Step 3
Step 4
Step 5
Step 6
Click a zone or zone set in the left pane.
Choose Edit > Rename .
An edit box appears around the zone or zone set name.
Enter a new name.
Click Activate or Distribute .
Cloning Zones, Zone Sets, FC Aliases, and Zone Attribute Groups
To clone a zone, zoneset, fcalias, or zone-attribute-group, follow these steps:
Step 1
Step 2
Step 3
Step 4 switch# configure terminal
Enters configuration mode.
switch(config)# zoneset clone oldname newnamevsan 2
Clones a zoneset in the specified VSAN.
switch(config)# zone clone oldname newname vsan 2
Clones a zone in the specified VSAN.
switch(config)# fcalias clone oldname newnamevsan 2
88
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Configuring and Managing Zones
Cloning Zones, Zone Sets, FC Aliases, and Zone Attribute Groups Using DCNM SAN Client
Step 5
Step 6
Clones a fcalias in the specified VSAN.
switch(config)# zone-attribute-group clone oldname newname vsan 2
Clones a zone attribute group in the specified VSAN.
switch(config)# zoneset activate name newname vsan 2
Activates the zoneset and updates the new zone name in the active zoneset.
Cloning Zones, Zone Sets, FC Aliases, and Zone Attribute Groups Using DCNM
SAN Client
To clone a zone, zone set, fcalias, or zone attribute group, follow these steps:
Step 1
Step 2
Step 3
Choose Zone > Edit Local Full Zone Database .
You see the Select VSAN dialog box.
Select a VSAN and click OK .
You see the Edit Local Full Zone Database dialog box for the selected VSAN.
Choose Edit > Clone .
You see the Clone Zoneset dialog box (see
Figure 37: Clone Zoneset Dialog Box, on page 89 ). The default name is the
word Clone followed by the original name.
Figure 37: Clone Zoneset Dialog Box
Step 4
Step 5
Change the name for the cloned entry.
Click OK to save the new clone.
The cloned database now appears along with the original database.
Migrating a Non-MDS Database
To use the Zone Migration Wizard to migrate a non-MDS database using DCNM SAN Client, follow these steps:
Step 1 Choose Zone > Migrate Non-MDS Database .
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
89
Configuring and Managing Zones
Clearing the Zone Server Database
Step 2
You see the Zone Migration Wizard.
Follow the prompts in the wizard to migrate the database.
Clearing the Zone Server Database
You can clear all configured information in the zone server database for the specified VSAN.
To clear the zone server database, use the following command: switch# clear zone database vsan 2
Note To clear the zone server database, refer to the Cisco MDS 9000 Series NX-OS Fabric Configuration Guide .
Note After issuing a clear zone database command, you must explicitly issue the copy running-config startup-config to ensure that the running configuration is used when the switch reboots.
Note Clearing a zoneset only erases the full zone database, not the active zone database.
Note After clearing the zone server database, you must explicitly copy the running configuration to the startup configuration to ensure that the running configuration is used when the switch reboots.
Advanced Zone Attributes
About Zone-Based Traffic Priority
The zoning feature provides an additional segregation mechanism to prioritize select zones in a fabric and set up access control between devices. Using this feature, you can configure the quality of service (QoS) priority as a zone attribute. You can assign the QoS traffic priority attribute to be high, medium, or low. By default, zones with no specified priority are implicitly assigned a low priority. Refer to the Cisco MDS 9000 NX-OS
Series Quality of Service Configuration Guide for more information.
To use this feature, you need to obtain the ENTERPRISE_PKG license (refer to the Cisco NX-OS Series
Licensing Guide ) and you must enable QoS in the switch (refer to the Cisco MDS 9000 Series NX-OS Quality of Service Configuration Guide ).
This feature allows SAN administrators to configure QoS in terms of a familiar data flow identification paradigm. You can configure this attribute on a zone-wide basis rather than between zone members.
90
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Configuring and Managing Zones
Configuring Zone-Based Traffic Priority
Caution If zone-based QoS is implemented in a switch, you cannot configure the interop mode in that VSAN.
Configuring Zone-Based Traffic Priority
To configure the zone priority, follow these steps:
Step 1
Step 2
Step 3 switch# configure terminal
Enters configuration mode.
switch(config)# zone name QosZone vsan 2
Example: switch(config-zone)#
Configures an alias name (QosZone) and enters zone configuration submode.
switch(config-zone)# attribute-group qos priority high
Example:
Step 4
Step 5
Step 6
Step 7
Configures this zone to assign high priority QoS traffic to each frame matching this zone in enhanced mode.
switch(config-zone)# attribute qos priority { high | low | medium }
Configures this zone to assign QoS traffic to each frame matching this zone.
switch(config-zone)# exit
Example: switch(config)#
Returns to configuration mode.
switch(config)# zoneset name QosZoneset vsan 2
Example: switch(config-zoneset)#
Configures a zoneset called QosZoneset for the specified VSAN (vsan 2) and enters zoneset configuration submode.
Tip To activate a zoneset, you must first create the zone and a zoneset.
switch(config-zoneset)# member QosZone
Adds QosZone as a member of the specified zoneset (QosZoneset).
Tip If the specified zone name was not previously configured, this command will return the Zone not present error message.
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
91
Configuring and Managing Zones
Configuring Zone-Based Traffic Priority Using DCNM SAN Client
Step 8
Step 9 switch(config-zoneset)# exit
Example: switch(config)#
Returns to configuration mode.
switch(config)# zoneset activate name QosZoneset vsan 2
Activates the specified zoneset.
Configuring Zone-Based Traffic Priority Using DCNM SAN Client
To configure the zone priority using DCNM SAN Client, follow these steps:
Step 1
Step 2
Expand a VSAN and then select a zone set in the Logical Domains pane.
Click the Policies tab in the Information pane.
You see the Zone policy information in the Information pane (see
Figure 38: Zone Policies Tab in the Information Pane, on page 92 ).
Figure 38: Zone Policies Tab in the Information Pane
Step 3
Step 4
Use the check boxes and drop-down menus to configure QoS on the default zone.
Click Apply Changes to save the changes.
Configuring Default Zone QoS Priority Attributes
QoS priority attribute configuration changes take effect when you activate the zoneset of the associated zone.
Note If a member is part of two zones with two different QoS priority attributes, the higher QoS value is implemented.
This situation does not arise in the VSAN-based QoS as the first matching entry is implemented.
92
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Configuring and Managing Zones
Configuring Default Zone QoS Priority Attributes Using DCNM SAN Client
To configure the QoS priority attributes for a default zone, follow these steps:
Step 1
Step 2
Step 3
Step 4 switch# configure terminal
Example: switch(config)#
Enters configuration mode.
switch(config)# zone default-zone vsan 1
Example: switch(config-default-zone)#
Enters the default zone configuration submode.
switch(config-default-zone)# attribute qos priority high
Sets the QoS priority attribute for frames matching these zones.
switch(config-default-zone)# no attribute qos priority high
Removes the QoS priority attribute for the default zone and reverts to default low priority.
Configuring Default Zone QoS Priority Attributes Using DCNM SAN Client
To configure the QoS priority attributes for a default zone using DCNM SAN Client, follow these steps:
Step 1
Step 2
Step 3
Choose Zone > Edit Local Full Zone Database .
You see the Select VSAN dialog box.
Select a VSAN and click OK .
You see the Edit Local Full Zone Database dialog box for the selected VSAN.
Choose Edit > Edit Default Zone Attributes to configure the default zone QoS priority attributes (see
Priority Attributes, on page 93
).
Figure 39: QoS Priority Attributes
Step 4
Step 5
Check the Permit QoS Traffic with Priority check box and set the Qos Priority drop-down menu to low , medium , or high .
Click OK to save these changes.
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
93
Configuring and Managing Zones
Configuring the Default Zone Policy
Configuring the Default Zone Policy
To permit or deny traffic in the default zone using DCNM SAN Client, follow these steps:
Step 1
Step 2
Step 3
Choose Zone > Edit Local Full Zone Database .
You see the Select VSAN dialog box.
Select a VSAN and click OK .
You see the Edit Local Full Zone Database dialog box for the selected VSAN.
Choose Edit > Edit Default Zone Attributes to configure the default zone QoS priority attributes.
You see the Modify Default Zone Properties dialog box (see
Figure 40: Modify Default Zone Properties Dialog Box, on page 94
).
Figure 40: Modify Default Zone Properties Dialog Box
Step 4
Step 5
Set the Policy drop-down menu to permit to permit traffic in the default zone, or set it to deny to block traffic in the default zone.
Click OK to save these changes.
About Smart Zoning
Smart zoning implements hard zoning of large zones with fewer hardware resources than was previously required. The traditional zoning method allows each device in a zone to communicate with every other device in the zone. The administrator is required to manage the individual zones according to the zone configuration guidelines. Smart zoning eliminates the need to create a single initiator to single target zones. By analyzing device-type information in the FCNS, useful combinations can be implemented at the hardware level by the
Cisco MDS NX-OS software, and the combinations that are not used are ignored. For example, initiator-target pairs are configured, but not initiator-initiator. The device is treated as unknown if:
• The FC4 types are not registered on the device.
• During Zone Convert, the device is not logged into the fabric.
• The zone is created, however, initiator, target, or initiator and target is not specified.
The device type information of each device in a smart zone is automatically populated from the Fibre Channel
Name Server (FCNS) database as host, target, or both. This information allows more efficient utilisation of switch hardware by identifying initiator-target pairs and configuring those only in hardware. In the event of
94
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Configuring and Managing Zones
Smart Zoning Member Configuration a special situation, such as a disk controller that needs to communicate with another disk controller, smart zoning defaults can be overridden by the administrator to allow complete control.
Note • Smart Zoning can be enabled at VSAN level but can also be disabled at zone level.
• Smart zoning is not supported on VSANs that have DMM, IOA, or SME applications enabled on them.
Smart Zoning Member Configuration
Table displays the supported smart zoning member configurations.
Table 7: Smart Zoning Configuration
Feature
PWWN
FCID
FCalias
Device-alias
Interface
IP address
No
No
Symbolic nodename No
FWWN No
Domain ID No
Supported
Yes
Yes
Yes
Yes
Enabling Smart Zoning on a VSAN
To configure the smart zoning for a VSAN, follow these steps:
Step 1
Step 2
Step 3 switch# configure terminal
Enters configuration mode.
switch(config)# zone smart-zoning enable vsan 1
Enables smart zoning on a VSAN.
switch(config)# no zone smart-zoning enable vsan 1
Disables smart zoning on a VSAN.
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
95
Configuring and Managing Zones
Setting Default Value for Smart Zoning
Setting Default Value for Smart Zoning
To set the default value, follow these steps:
Step 1
Step 2
Step 3 switch# configure terminal
Enters configuration mode.
switch(config)# system default zone smart-zone enable
Enables smart zoning on a VSAN that are created based on the specified default value.
switch(config)# no system default zone smart-zone enable
Disables smart zoning on a VSAN.
Converting Zones Automatically to Smart Zoning
To fetch the device-type information from nameserver and to add that information to the member, follow the steps below: This can be performed at zone, zoneset, FCalias, and VSAN levels. After the zoneset is converted to smart zoning, you need to activate zoneset.
Step 1
Step 2
Step 3
Step 4
Step 5
Step 6
Step 7 switch# configure terminal
Enters configuration mode.
switch(config)# zone convert smart-zoning fcalias name <alias-name> vsan <vsan no>
Fetches the device type information from the nameserver for the fcalias members.
Note When the zone convert command is run, the FC4-Type should be SCSI-FCP. The SCSI-FCP has bits which determines whether the device is an initiator or target. If initiator and target are both set, the device is treated as both.
switch(config)# zone convert smart-zoning zone name <zone name> vsan <vsan no>
Fetches the device type information from the nameserver for the zone members.
switch(config)# zone convert smart-zoning zoneset name <zoneset name> vsan <vsan no>
Fetches the device type information from the nameserver for all the zones and fcalias members in the specified zoneset.
switch(config)# zone convert smart-zoning vsan <vsan no>
Fetches the device type information from the nameserver for all the zones and fcalias members for all the zonesets present in the VSAN.
switch(config)# show zone smart-zoning auto-conv status vsan 1
Displays the previous auto-convert status for a VSAN.
switch(config)# show zone smart-zoning auto-conv log errors
96
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Configuring and Managing Zones
Configuring Device Types for Zone Members
Displays the error-logs for smart-zoning auto-convert.
What to do next
Use the show fcns database command to check if the device is initiator, target or both: switch# show fcns database
VSAN 1:
--------------------------------------------------------------------------
FCID TYPE PWWN (VENDOR) FC4-TYPE:FEATURE
--------------------------------------------------------------------------
0x9c0000 N 21:00:00:e0:8b:08:96:22 (Company 1) scsi-fcp:init
0x9c0100 N 10:00:00:05:30:00:59:1f (Company 2) ipfc
0x9c0200 N 21:00:00:e0:8b:07:91:36 (Company 3) scsi-fcp:init
0x9c03d6 NL 21:00:00:20:37:46:78:97 (Company 4) scsi-fcp:target
Configuring Device Types for Zone Members
Note When device types are explicitly configured in smart zoning, any device must be configured with the same type in all zones of which the device is a member. A zone member must not be configured as initiator in some zones and target in other zones.
To configure the device types for zone members, follow these step:
Step 1
Step 2
Step 3
Step 4 switch# configure terminal
Enters configuration mode.
switch(config-zoneset-zone)# member device-alias name both
Configures the device type for the device-alias member as both. For every supported member-type, init, target, and both are supported.
switch(config-zoneset-zone)# member pwwn number target
Configures the device type for the pwwn member as target. For every supported member-type, init, target, and both are supported.
switch(config-zoneset-zone)# member fcid number
Configures the device type for the FCID member. There is no specific device type that is configured. For every supported member-type, init, target, and both are supported.
Note When there is no specific device type configured for a zone member, at the backend, zone entries that are generated are created as device type both.
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
97
Configuring and Managing Zones
Removing Smart Zoning Configuration
Removing Smart Zoning Configuration
To remove the smart zoning configuration, follow this steps:
Step 1
Step 2
Step 3
Step 4 switch(config)# clear zone smart-zoning fcalias name alias-name vsan number
Removes the device type configuration for all the members of the specified fcalias.
switch(config)# clear zone smart-zoning zone name zone name vsan number
Removes the device type configuration for all the members of the specified zone.
switch(config)# clear zone smart-zoning zoneset name zoneset name vsan number
Removes the device type configuration for all the members of the zone and fcalias for the specified zoneset.
switch(config)# clear zone smart-zoning vsan number
Removes the device type configuration for all the members of the zone and fcalias of all the specified zonesets in the
VSAN.
Disabling Smart Zoning at Zone Level in the Basic Zoning Mode
To disable smart zoning at the zone level for a VSAN in basic zoning mode, follow these steps:
Step 1
Step 2
Step 3 switch# configure terminal
Enters configuration mode.
switch(config)# zone name zone1 vsan 1
Configures a zone name.
switch(config-zone)# attribute disable-smart-zoning
Disables Smart Zoning for the selected zone.
Note This command only disables the smart zoning for the selected zone and does not remove the device type configurations.
Disabling Smart Zoning at Zone Level for a VSAN in the Enhanced Zoning
Mode
To disable smart zoning at the zone level for a VSAN in enhanced zoning mode, follow these steps:
Step 1 switch# configure terminal
Enters configuration mode.
98
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Configuring and Managing Zones
Disabling Smart Zoning at Zone Level Using DCNM SAN Client
Step 2
Step 3
Step 4
Step 5
Step 6 switch(config)# zone-attribute-group name disable-sz vsan 1
Creates an enhanced zone session.
switch(config-attribute-group)# disable-smart-zoning
Disables Smart Zoning for the selected zone.
Note This command only disables the smart zoning for the selected zone and does not remove the device type configurations.
switch(config-attribute-group)# zone name prod vsan 1
Configures a zone name.
switch(config-zone)# attribute-group disable-sz
Configures to assign a group-attribute name for the selected zone.
switch(config-zone)# zone commit vsan 1
Commits zoning changes to the selected VSAN.
Disabling Smart Zoning at Zone Level Using DCNM SAN Client
To broadcast frames in the basic zoning mode using DCNM SAN Client, follow these steps:
Step 1
Step 2
Expand a VSAN and then select a zone set in the Logical Domains pane.
Click the Policies tab in the Information pane.
You see the Zone policy information in the Information pane.
Figure 41: Zone Policy Information
Step 3
Step 4
Check the Broadcast check box to enable broadcast frames on the default zone.
Click Apply Changes to save these changes.
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
99
Configuring and Managing Zones
Displaying Zone Information
Displaying Zone Information
You can view any zone information by using the show command. If you request information for a specific object (for example, a specific zone, zoneset, VSAN, or alias, or keywords such as brief or active ), only information for the specified object is displayed. If you do not request specific information, all available information is displayed.
Displays Zone Information for All VSANs switch# show zone zone name Zone3 vsan 1 pwwn 21:00:00:20:37:6f:db:dd pwwn 21:00:00:20:37:9c:48:e5 zone name Zone2 vsan 2 fwwn 20:41:00:05:30:00:2a:1e fwwn 20:42:00:05:30:00:2a:1e fwwn 20:43:00:05:30:00:2a:1e zone name Zone1 vsan 1 pwwn 21:00:00:20:37:6f:db:dd pwwn 21:00:00:20:37:a6:be:2f pwwn 21:00:00:20:37:9c:48:e5 fcalias Alias1 zone name Techdocs vsan 3 ip-address 10.15.0.0 255.255.255.0
zone name Zone21 vsan 5 pwwn 21:00:00:20:37:a6:be:35 pwwn 21:00:00:20:37:a6:be:39 fcid 0xe000ef fcid 0xe000e0 symbolic-nodename iqn.test
fwwn 20:1f:00:05:30:00:e5:c6 fwwn 12:12:11:12:11:12:12:10 interface fc1/5 swwn 20:00:00:05:30:00:2a:1e ip-address 12.2.4.5 255.255.255.0
fcalias name Alias1 vsan 1 pwwn 21:00:00:20:37:a6:be:35 zone name Zone2 vsan 11 interface fc1/5 pwwn 20:4f:00:05:30:00:2a:1e zone name Zone22 vsan 6 fcalias name Alias1 vsan 1 pwwn 21:00:00:20:37:a6:be:35 zone name Zone23 vsan 61 pwwn 21:00:00:04:cf:fb:3e:7b lun 0000
Displays Zone Information for a Specific VSAN switch# show zone vsan 1 zone name Zone3 vsan 1 pwwn 21:00:00:20:37:6f:db:dd pwwn 21:00:00:20:37:9c:48:e5 zone name Zone2 vsan 1 fwwn 20:4f:00:05:30:00:2a:1e fwwn 20:50:00:05:30:00:2a:1e fwwn 20:51:00:05:30:00:2a:1e fwwn 20:52:00:05:30:00:2a:1e fwwn 20:53:00:05:30:00:2a:1e zone name Zone1 vsan 1 pwwn 21:00:00:20:37:6f:db:dd pwwn 21:00:00:20:37:a6:be:2f
100
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Configuring and Managing Zones pwwn 21:00:00:20:37:9c:48:e5 fcalias Alias1
Use the show zoneset command to view the configured zonesets.
Displays Configured Zoneset Information switch# show zoneset vsan 1 zoneset name ZoneSet2 vsan 1 zone name Zone2 vsan 1 fwwn 20:4e:00:05:30:00:2a:1e fwwn 20:4f:00:05:30:00:2a:1e fwwn 20:50:00:05:30:00:2a:1e fwwn 20:51:00:05:30:00:2a:1e fwwn 20:52:00:05:30:00:2a:1e zone name Zone1 vsan 1 pwwn 21:00:00:20:37:6f:db:dd pwwn 21:00:00:20:37:a6:be:2f pwwn 21:00:00:20:37:9c:48:e5 fcalias Alias1 zoneset name ZoneSet1 vsan 1 zone name Zone1 vsan 1 pwwn 21:00:00:20:37:6f:db:dd pwwn 21:00:00:20:37:a6:be:2f pwwn 21:00:00:20:37:9c:48:e5 fcalias Alias1
Displays Configured Zoneset Information for a Range of VSANs switch# show zoneset vsan 2-3 zoneset name ZoneSet2 vsan 2 zone name Zone2 vsan 2 fwwn 20:52:00:05:30:00:2a:1e fwwn 20:53:00:05:30:00:2a:1e fwwn 20:54:00:05:30:00:2a:1e fwwn 20:55:00:05:30:00:2a:1e fwwn 20:56:00:05:30:00:2a:1e zone name Zone1 vsan 2 pwwn 21:00:00:20:37:6f:db:dd pwwn 21:00:00:20:37:a6:be:2f pwwn 21:00:00:20:37:9c:48:e5 fcalias Alias1 zoneset name ZoneSet3 vsan 3 zone name Zone1 vsan 1 pwwn 21:00:00:20:37:6f:db:dd pwwn 21:00:00:20:37:a6:be:2f pwwn 21:00:00:20:37:9c:48:e5 fcalias Alias1
Use the show zone name command to display members of a specific zone.
Displays Members of a Zone switch# show zone name Zone1 zone name Zone1 vsan 1 pwwn 21:00:00:20:37:6f:db:dd pwwn 21:00:00:20:37:a6:be:2f pwwn 21:00:00:20:37:9c:48:e5 fcalias Alias1
Displaying Zone Information
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
101
Configuring and Managing Zones
Displaying Zone Information
Use the show fcalias command to display fcalias configuration.
Displays fcalias Configuration switch# show fcalias vsan 1 fcalias name Alias2 vsan 1 fcalias name Alias1 vsan 1 pwwn 21:00:00:20:37:6f:db:dd pwwn 21:00:00:20:37:9c:48:e5
Use the show zone member command to display all zones to which a member belongs using the FC ID.
Displays Membership Status switch# show zone member pwwn 21:00:00:20:37:9c:48:e5
VSAN: 1 zone Zone3 zone Zone1 fcalias Alias1
Use the show zone statistics command to display the number of control frames exchanged with other switches.
Displays Zone Statistics switch# show zone statistics
Statistics For VSAN: 1
**********************************
Number of Merge Requests Sent: 24
Number of Merge Requests Recvd: 25
Number of Merge Accepts Sent: 25
Number of Merge Accepts Recvd: 25
Number of Merge Rejects Sent: 0
Number of Merge Rejects Recvd: 0
Number of Change Requests Sent: 0
Number of Change Requests Recvd: 0
Number of Change Rejects Sent: 0
Number of Change Rejects Recvd: 0
Number of GS Requests Recvd: 0
Number of GS Requests Rejected: 0
Statistics For VSAN: 2
**********************************
Number of Merge Requests Sent: 4
Number of Merge Requests Recvd: 4
Number of Merge Accepts Sent: 4
Number of Merge Accepts Recvd: 4
Number of Merge Rejects Sent: 0
Number of Merge Rejects Recvd: 0
Number of Change Requests Sent: 0
Number of Change Requests Recvd: 0
Number of Change Rejects Sent: 0
Number of Change Rejects Recvd: 0
Number of GS Requests Recvd: 0
Number of GS Requests Rejected: 0
Displays LUN Zone Statistics switch# show zone statistics lun-zoning
LUN zoning statistics for VSAN: 1
************************************************************
102
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Configuring and Managing Zones
Displaying Zone Information
S-ID: 0x123456, D-ID: 0x22222, LUN: 00:00:00:00:00:00:00:00
------------------------------------------------------------
Number of Inquiry commands received:
Number of Inquiry data No LU sent:
10
5
Number of Report LUNs commands received:
Number of Request Sense commands received:
Number of Other commands received:
10
1
0
Number of Illegal Request Check Condition sent: 0
S-ID: 0x123456, D-ID: 0x22222, LUN: 00:00:00:00:00:00:00:01
------------------------------------------------------------
Number of Inquiry commands received: 1
Number of Inquiry data No LU sent: 1
Number of Request Sense commands received:
Number of Other commands received:
Number of Illegal Request Check Condition sent: 0
1
0
Displays LUN Zone Statistics
Need the latest output switch# show zone statistics read-only-zoning
Read-only zoning statistics for VSAN: 2
************************************************************
S-ID: 0x33333, D-ID: 0x11111, LUN: 00:00:00:00:00:00:00:64
------------------------------------------------------------
Number of Data Protect Check Condition Sent: 12
Displays Active Zone Sets switch# show zoneset active zoneset name ZoneSet1 vsan 1 zone name zone1 vsan 1 fcid 0x080808 fcid 0x090909 fcid 0x0a0a0a zone name zone2 vsan 1
* fcid 0xef0000 [pwwn 21:00:00:20:37:6f:db:dd]
* fcid 0xef0100 [pwwn 21:00:00:20:37:a6:be:2f]
Displays Brief Descriptions of Zone Sets switch# show zoneset brief zoneset name ZoneSet1 vsan 1 zone zone1 zone zone2
Displays Active Zones switch# show zone active zone name Zone2 vsan 1
* fcid 0x6c01ef [pwwn 21:00:00:20:37:9c:48:e5] zone name IVRZ_IvrZone1 vsan 1 pwwn 10:00:00:00:77:99:7a:1b
* fcid 0xce0000 [pwwn 10:00:00:00:c9:2d:5a:dd] zone name IVRZ_IvrZone4 vsan 1
* fcid 0xce0000 [pwwn 10:00:00:00:c9:2d:5a:dd]
* fcid 0x6c01ef [pwwn 21:00:00:20:37:9c:48:e5] zone name Zone1 vsan 1667 fcid 0x123456
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
103
Configuring and Managing Zones
Displaying Zone Information zone name $default_zone$ vsan 1667
Displays Active Zone Sets switch# show zoneset active zoneset name ZoneSet4 vsan 1 zone name Zone2 vsan 1
* fcid 0x6c01ef [pwwn 21:00:00:20:37:9c:48:e5] zone name IVRZ_IvrZone1 vsan 1 pwwn 10:00:00:00:77:99:7a:1b
* fcid 0xce0000 [pwwn 10:00:00:00:c9:2d:5a:dd] zoneset name QosZoneset vsan 2 zone name QosZone vsan 2 attribute qos priority high
* fcid 0xce0000 [pwwn 10:00:00:00:c9:2d:5a:dd]
* fcid 0x6c01ef [pwwn 21:00:00:20:37:9c:48:e5]
Active zoneset vsan 1667 zone name Zone1 vsan 1667 fcid 0x123456 zone name $default_zone$ vsan 1667
Displays Zone Status switch(config)# show zone status
VSAN: 1 default-zone: deny distribute: active only Interop: default mode: basic merge-control: allow session: none hard-zoning: enabled broadcast: disabled smart-zoning: disabled rscn-format: fabric-address activation overwrite control:disabled
Default zone: qos: none broadcast: disabled ronly: disabled
Full Zoning Database :
DB size: 4 bytes
Zonesets:0 Zones:0 Aliases: 0
Active Zoning Database :
Database Not Available
Current Total Zone DB Usage: 4 / 2097152 bytes (0 % used)
Pending (Session) DB size:
Full DB Copy size: n/a
Active DB Copy size: n/a
SFC size: 4 / 2097152 bytes (0 % used)
Status:
VSAN: 8 default-zone: deny distribute: full Interop: default mode: basic merge-control: allow session: none hard-zoning: enabled broadcast: disabled smart-zoning: disabled rscn-format: fabric-address
Default zone: qos: none broadcast: disabled ronly: disabled
Full Zoning Database :
DB size: 1946498 bytes
Zonesets:6 Zones:8024 Aliases: 0
Active Zoning Database :
DB size: 150499 bytes
Name: zoneset-1000 Zonesets:1 Zones:731
Current Total Zone DB Usage: 2096997 / 2097152 bytes (99 % used)
Pending (Session) DB size:
Full DB Copy size: n/a
104
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Configuring and Managing Zones
Displaying Zone Information
Active DB Copy size: n/a
SFC size: 2096997 / 2097152 bytes (99 % used)
Status: Zoneset distribution failed [Error: Fabric changing Dom 33]: at 17:05:06 UTC Jun 16 2014
VSAN: 9 default-zone: deny distribute: full Interop: default mode: enhanced merge-control: allow session: none hard-zoning: enabled broadcast: enabled smart-zoning: disabled rscn-format: fabric-address
Default zone: qos: none broadcast: disabled ronly: disabled
Full Zoning Database :
DB size: 2002584 bytes
Zonesets:4 Zones:7004 Aliases: 0 Attribute-groups: 1
Active Zoning Database :
DB size: 94340 bytes
Name: zoneset-hac13-200 Zonesets:1 Zones:176
Current Total Zone DB Usage: 2096924 / 2097152 bytes (99 % used)
Pending (Session) DB size:
Full DB Copy size: 0 bytes
Active DB Copy size: 0 bytes
SFC size: 0 / 2097152 bytes (0 % used)
Status: Activation completed at 17:28:04 UTC Jun 16 2014
VSAN: 12 default-zone: deny distribute: full Interop: default mode: enhanced merge-control: allow session: none hard-zoning: enabled broadcast: enabled smart-zoning: disabled rscn-format: fabric-address
Default zone: qos: none broadcast: disabled ronly: disabled
Full Zoning Database :
DB size: 84 bytes
Zonesets:0 Zones:1 Aliases: 0 Attribute-groups: 1
Active Zoning Database :
DB size: 144 bytes
Name: zs1 Zonesets:1 Zones:2
Current Total Zone DB Usage: 228 / 2097152 bytes (0 % used)
Pending (Session) DB size:
Full DB Copy size: 0 bytes
Active DB Copy size: 0 bytes
SFC size: 0 / 2097152 bytes (0 % used)
Status: Commit completed at 14:39:33 UTC Jun 27 201
Use the show zone command to display the zone attributes for all configured zones.
Displays Zone Statistics switch# show zone zone name lunSample vsan 1 zone name ReadOnlyZone vsan 2 attribute read-only
<-----------------Read-write attribute
<-----------------Read-only attribute
Use the show running and show zone active commands to display the configured interface-based zones.
Displays the Interface-Based Zones switch# show running zone name if-zone vsan 1 member interface fc2/15 swwn 20:00:00:0c:88:00:4a:e2 member fwwn 20:4f:00:0c:88:00:4a:e2
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
105
Configuring and Managing Zones
Displaying Zone Information member interface fc2/1 swwn 20:00:00:05:30:00:4a:9e member pwwn 22:00:00:20:37:39:6b:dd
Displays the fWWNs and Interfaces in an Active Zone switch# show zone active zone name if-zone vsan 1
* fcid 0x7e00b3 [interface fc2/15 swwn 20:00:00:0c:88:00:4a:e2]
* fcid 0x7e00b1 [interface fc2/15 swwn 20:00:00:0c:88:00:4a:e2]
* fcid 0x7e00ac [interface fc2/15 swwn 20:00:00:0c:88:00:4a:e2]
* fcid 0x7e00b3 [fwwn 20:4f:00:0c:88:00:4a:e2]
* fcid 0x7e00b1 [fwwn 20:4f:00:0c:88:00:4a:e2]
* fcid 0x7e00ac [fwwn 20:4f:00:0c:88:00:4a:e2] interface fc2/1 swwn 20:00:00:05:30:00:4a:9e
A similar output is also available on the remote switch (see the following example).
Displays the Local Interface Active Zone Details for a Remote Switch switch# show zone active zone name if-zone vsan 1
* fcid 0x7e00b3 [interface fc2/15 swwn 20:00:00:0c:88:00:4a:e2]
* fcid 0x7e00b1 [interface fc2/15 swwn 20:00:00:0c:88:00:4a:e2]
* fcid 0x7e00ac [interface fc2/15 swwn 20:00:00:0c:88:00:4a:e2]
* fcid 0x7e00b3 [fwwn 20:4f:00:0c:88:00:4a:e2]
* fcid 0x7e00b1 [fwwn 20:4f:00:0c:88:00:4a:e2]
* fcid 0x7e00ac [fwwn 20:4f:00:0c:88:00:4a:e2] interface fc2/1 swwn 20:00:00:05:30:00:4a:9e
Displays the Zone Status for a VSAN switch(config)# show zone status vsan 1
VSAN: 1 default-zone: deny distribute: active only Interop: default mode: basic merge-control: allow session: none hard-zoning: enabled broadcast: disabled smart-zoning: disabled rscn-format: fabric-address activation overwrite control:disabled
Default zone: qos: none broadcast: disabled ronly: disabled
Full Zoning Database :
DB size: 4 bytes
Zonesets:0 Zones:0 Aliases: 0
Active Zoning Database :
Database Not Available
Current Total Zone DB Usage: 4 / 2097152 bytes (0 % used)
Pending (Session) DB size:
Full DB Copy size: n/a
Active DB Copy size: n/a
SFC size: 4 / 2097152 bytes (0 % used)
Status:
Displays the Zone Policy for a VSAN switch# show zone policy vsan 1
Vsan: 1
Default-zone: deny
Distribute: full
Broadcast: enable
Merge control: allow
106
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Configuring and Managing Zones
Displaying Zone Information
Generic Service: read-write
Smart-zone: enabled
Displays How to Create a Zone Attribute-Group to for a VSAN in the Enhanced Mode to Disable Smart
Zoning at an Individual Zone Level
Note After the attribute-group is created, it needs to be applied to any zones requiring smart zoning to be disabled.
config# zone-attribute-group name <name> vsan 1 config-attribute-group# disable-smart-zoning config-attribute-group# exit config# zone commit vsan 1
Displays how to Auto-convert Zones config# show zoneset vsan 1 zoneset name ZSv1 vsan 1 zone name ddasZone vsan 1 device-alias Init1 device-alias Init2 device-alias Init3 device-alias Target1 config# zone convert smart-zoning vsan 1 smart-zoning auto_convert initiated. This operation can take few minutes. Please wait..
config# show zoneset vsan1 zoneset name ZSv1 vsan 1 zone name ddasZone vsan 1 device-alias Init1 init device-alias Init2 init device-alias Init3 init device-alias Target1 target
Displays how to Clear Device type Configuration for Members config# show zoneset vsan 1 zoneset name ZSv1 vsan 1 zone name ddasZone vsan 1 device-alias Init1 init device-alias Init2 init device-alias Init3 init device-alias Target1 target config# clear zone smart-zoning vsan1 config# show zoneset vsan 1 zoneset name ZSv1 vsan 1 zone name ddasZone vsan 1 device-alias Init1 device-alias Init2 device-alias Init3 device-alias Target1
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
107
Configuring and Managing Zones
Enhanced Zoning
Enhanced Zoning
The zoning feature complies with the FC-GS-4 and FC-SW-3 standards. Both standards support the basic zoning functionalities explained in the previous section and the enhanced zoning functionalities described in this section.
About Enhanced Zoning
Table 8: Advantages of Enhanced Zoning , on page 108
lists the advantages of the enhanced zoning feature in all switches in the Cisco MDS 9000 Series.
Table 8: Advantages of Enhanced Zoning
Basic Zoning Enhanced Zoning Enhanced Zoning Advantages
Administrators can make simultaneous configuration changes. Upon activation, one administrator can overwrite another administrator’s changes.
Performs all configurations within a single configuration session. When you begin a session, the switch locks the entire fabric to implement the change.
One configuration session for the entire fabric to ensure consistency within the fabric.
If a zone is part of multiple zonesets, you create an instance of this zone in each zoneset.
References to the zone are used by the zonesets as required once you define the zone.
Reduced payload size as the zone is referenced. The size is more pronounced with bigger databases.
The default zone policy is defined per switch. To ensure smooth fabric operation, all switches in the fabric must have the same default zone setting.
Enforces and exchanges the default zone setting throughout the fabric.
Fabric-wide policy enforcement reduces troubleshooting time.
To retrieve the results of the activation on a per switch basis, the managing switch provides a combined status about the activation. It does not identify the failure switch.
Retrieves the activation results and the nature of the problem from each remote switch.
To distribute the zoning database, you must reactivate the same zoneset. The reactivation may affect hardware changes for hard zoning on the local switch and on remote switches.
Implements changes to the zoning database and distributes it without reactivation.
Enhanced error reporting eases the troubleshooting process.
Distribution of zone sets without activation avoids hardware changes for hard zoning in the switches.
The MDS-specific zone member types (IPv4 address,
IPv6 address, symbolic node name, and other types) may be used by other non-Cisco switches. During a merge, the MDS-specific types can be misunderstood by the non-Cisco switches.
Provides a vendor ID along with a vendor-specific type value to uniquely identify a member type.
The fWWN-based zone membership is only supported in Cisco interop mode.
Supports fWWN-based membership in the standard interop mode (interop mode
1).
Unique vendor type.
The fWWN-based member type is standardized.
108
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Configuring and Managing Zones
Changing from Basic Zoning to Enhanced Zoning
Changing from Basic Zoning to Enhanced Zoning
To change to the enhanced zoning mode from the basic mode, follow these steps:
Step 1
Step 2
Verify that all switches in the fabric are capable of working in the enhanced mode.
If one or more switches are not capable of working in enhanced mode, then your request to move to enhanced mode is rejected.
Set the operation mode to enhanced zoning mode. By doing so, you will automatically start a session, acquire a fabric wide lock, distribute the active and full zoning database using the enhanced zoning data structures, distribute zoning policies and then release the lock. All switches in the fabric then move to the enhanced zoning mode.
Tip After moving from basic zoning to enhanced zoning, we recommend that you save the running configuration.
Changing from Enhanced Zoning to Basic Zoning
The standards do not allow you to move back to basic zoning. However, Cisco MDS switches allow this move to enable you to downgrade and upgrade to other Cisco SAN-OS or Cisco NX-OS releases.
To change to the basic zoning mode from the enhanced mode, follow these steps:
Step 1
Step 2
Verify that the active and full zoneset do not contain any configuration that is specific to the enhanced zoning mode.
If such configurations exist, delete them before proceeding with this procedure. If you do not delete the existing configuration, the Cisco NX-OS software automatically removes them.
Set the operation mode to basic zoning mode. By doing so, you will automatically start a session, acquire a fabric wide lock, distribute the zoning information using the basic zoning data structure, apply the configuration changes and release the lock from all switches in the fabric. All switches in the fabric then move to basic zoning mode.
Note If a switch running Cisco SAN-OS Release 2.0(1b) and NX-OS 4(1b) or later, with enhanced zoning enabled is downgraded to Cisco SAN-OS Release 1.3(4), or earlier, the switch comes up in basic zoning mode and cannot join the fabric because all the other switches in the fabric are still in enhanced zoning mode.
Enabling Enhanced Zoning
By default, the enhanced zoning feature is disabled on all switches in the Cisco MDS 9000 Series.
To enable enhanced zoning in a VSAN, follow these steps:
Step 1
Step 2 switch# configure terminal
Enters configuration mode.
switch(config)# zone mode enhanced vsan id
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
109
Configuring and Managing Zones
Enabling Enhanced Zoning Using DCNM SAN Client
Step 3
Enables enhanced zoning in the specified VSAN.
switch(config)# no zone mode enhanced vsan id
Disables enhanced zoning in the specified VSAN.
Enabling Enhanced Zoning Using DCNM SAN Client
To enable enhanced zoning in a VSAN using DCNM SAN Client, follow these steps:
Step 1
Step 2
Step 3
Step 4
Expand a VSAN and then select a zone set in the Logical Domains pane.
You see the zone set configuration in the Information pane.
Click the Enhanced tab.
You see the current enhanced zoning configuration.
From the Action drop-down menu, choose enhanced to enable enhanced zoning in this VSAN.
Click Apply Changes to save these changes.
Modifying the Zone Database
Modifications to the zone database is done within a session. A session is created at the time of the first successful configuration command. On creation of a session, a copy of the zone database is created. Any changes done within the session are performed on this copy of the zoning database. These changes in the copy zoning database are not applied to the effective zoning database until you commit the changes. Once you apply the changes, the session is closed.
If the fabric is locked by another user and for some reason the lock is not cleared, you can force the operation and close the session. You must have permission (role) to clear the lock in this switch and perform the operation on the switch from where the session was originally created.
To commit or discard changes to the zoning database in a VSAN, follow these steps:
Step 1
Step 2
Step 3
Step 4 switch# configure terminal
Enters configuration mode.
switch(config)# zone commit vsan 2
Applies the changes to the enhanced zone database and closes the session.
switch(config)# zone commit vsan 3 force
Forcefully applies the changes to the enhanced zone database and closes the session created by another user.
switch(config)# no zone commit vsan 2
Discards the changes to the enhanced zone database and closes the session.
110
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Configuring and Managing Zones
Enabling Automatic Zone Pending Diff Display
Step 5 switch(config)# no zone commit vsan 3 force
Forcefully discards the changes to the enhanced zone database and closes the session created by another user.
Note You do not have to issue the copy running-config startup-config command to store the active zoneset.
However, you need to issue the copy running-config startup-config command to explicitly store full zone sets. If there is more than one switch in a fabric, the copy running-config startup-config fabric command should be issued. The fabric keyword causes the copy running-config startup-config command to be issued on all the switches in the fabric, and also saves the full zone information to the startup-config on all the switches in the fabric. This is important in the event of a switch reload or power cycle.
Enabling Automatic Zone Pending Diff Display
To enable the display of pending-diff and subsequent confirmation on issuing a zone commit in enhanced mode, follow these steps:
Step 1
Step 2
Step 3
Step 4 switch# configure terminal
Enters configuration mode.
switch(config)# zone confirm-commit enable vsan vsan-id
Enables the confirm-commit option for zone database for a given VSAN.
switch(config-zone)# zone commit vsan 12
If the zone confirm-commit command is enabled for a VSAN, on committing the pending database, the pending-diff is displayed on the console and the user is prompted for Yes or No. If the zone confirm-commit command is disabled, the pending-diff is not displayed and the user is not prompted for Yes or No.
switch(config)# no zone commit vsan 12
If the zone confirm-commit command is enabled for a VSAN, on discarding the pending database, the pending-diff is displayed on the console and the user is prompted for Yes or No. If the zone confirm-commit command is disabled, the pending-diff is not displayed and the user is not prompted for Yes or No.
Releasing Zone Database Locks
To release the session lock on the zoning database on the switches in a VSAN, use the no zone commit vsan command from the switch where the database was initially locked.
switch# configure terminal switch(config)# no zone commit vsan 2
If session locks remain on remote switches after using the no zone commit vsan command, you can use the clear zone lock vsan command on the remote switches.
switch# clear zone lock vsan 2
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
111
Configuring and Managing Zones
Creating Attribute Groups
Note We recommend using the no zone commit vsan command first to release the session lock in the fabric. If that fails, use the clear zone lock vsan command on the remote switches where the session is still locked.
Creating Attribute Groups
In enhanced mode, you can directly configure attributes using attribute groups.
To configure attribute groups, follow these steps:
Step 1
Step 2
Step 3
Step 4
Create an attribute group.
Example: switch# confgure terminal switch(config)# zone-attribute-group name SampleAttributeGroup vsan 2 switch(config-attribute-group)#
Add the attribute to an attribute-group object.
Example: switch(config-attribute-group)# readonly switch(config-attribute-group)# broadcast switch(config-attribute-group)# qos priority medium readonly and broadcast commands are not supported from 5.2 release onwards.
Attach the attribute-group to a zone.
Example: switch(config)# zone name Zone1 vsan 2 switch(config-zone)# attribute-group SampleAttributeGroup switch(config-zone)# exit switch(config)#
Activate the zoneset.
Example: switch(config)# zoneset activate name Zoneset1 vsan 2
The attribute-groups are expanded and only the configured attributes are present in the active zoneset.
To configure attribute groups, refer to the Cisco MDS 9000 Series NX-OS Fabric Configuration Guide .
Merging the Database
The merge behavior depends on the fabric-wide merge control setting:
• Restrict—If the two databases are not identical, the ISLs between the switches are isolated.
112
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Configuring and Managing Zones
Merge Process
• Allow—The two databases are merged using the merge rules specified in the
Table 9: Database Zone Merge Status
Local Database Adjacent
Database
Merge Status Results of the Merge
The databases contain zone sets with the same name
but different zones, aliases, and attributes groups.
Successful.
The union of the local and adjacent databases.
ISLs are isolated.
The databases contains a zone, zone alias, or zone attribute group object with same name 1 but different members.
Failed.
Note .In the enhanced zoning mode, the active zoneset does not have a name in interop mode 1. The zoneset names are only present for full zone sets.
Empty.
Contains data.
Successful.
Contains data.
Empty.
Successful.
The adjacent database information populates the local database.
The local database information populates the adjacent database.
1
In the enhanced zoning mode, the active zoneset does not have a name in interop mode 1. The zoneset names are only present for full zone sets.
Caution Remove all non-PWWN-type zone entries on all MDS switches running Cisco SAN-OS prior to merging fabrics if there is a Cisco MDS 9020 switch running FabricWare in the adjacent fabric.
Merge Process
When two Fibre Channel (FC) switches that have already been configured with active zonesets and are not yet connected are brought together with an Extended ISL (EISL) link, the zonesets merge. However, steps must be taken to ensure zone consistency before configuring and activating new zones.
Best Practices
When a zone merge occurs, as long as there is not competing information, each switch learns the others zones.
Each switch then has three configuration entities. The switches have:
• The saved configuration in NVRAM. This is the configuration as it was the last time the copy running-configuration startup-configuration command was issued.
• The running configuration. This represents the configuration brought into memory upon the last time the
MDS was brought up, plus any changes that have been made to the configuration. With reference to the
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
113
Configuring and Managing Zones
Merge Process zoning information, the running configuration represents the configurable database, known as the full database.
• The configured zoning information from the running configuration plus the zoning information learned from the zone merge. This combination of configured and learned zone information is the active zoneset.
The merge process operates as follows:
1.
The software compares the protocol versions. If the protocol versions differ, then the ISL is isolated.
2.
If the protocol versions are the same, then the zone policies are compared. If the zone policies differ, then the ISL is isolated.
3.
If the zone merge options are the same, then the comparison is implemented based on the merge control setting.
a.
If the setting is restrict, the active zoneset and the full zoneset should be identical. Otherwise the link is isolated.
b.
If the setting is allow, then the merge rules are used to perform the merge.
When an MDS is booted, it comes up with the configuration previously saved in NVRAM. If you configured the switch after loading the configuration from NVRAM, there is a difference between the bootup and running configuration until the running configuration is saved to the startup configuration. This can be likened to having a file on the local hard drive of your PC. The file is saved and static, but if you open the file and edit, there exists a difference between the changed file and the file that still exists on saved storage. Only when you save the changes, does the saved entity look represent the changes made to the file.
When zoning information is learned from a zone merge, this learned information is not part of the running configuration. Only when the zone copy active-zoneset full-zoneset vsan X command is issued, the learned information becomes incorporated into the running configuration. This is key because when a zone merge is initiated by a new EISL link or activating a zoneset, the zoneset part is ignored by the other switch and the member zone information is considered topical.
Caution The zone copy command will delete all fcalias configuration.
Example
For example, you have two standalone MDS switches, already in place and each with their own configured zone and zoneset information. Switch 1 has an active zoneset known as set A, and Switch 2 has an active zoneset known as set B. Within set A on Switch 1 is zone 1, and on Switch 2, set B has member zone 2. When an ISL link is created between these two switches, each sends their zoneset including their zone information to the other switch. On a merge, the switch will select zoneset name with the higher ASCII value and then merge their zone member. After the merge, both switches will have a zoneset name set B with zone member zone 1 and zone 2.
Everything should be still working for all of the devices in zone 1 and zone 2. To add a new zone, you have to create a new zone, add the new zone to the zoneset, and then activate the zoneset.
Step-by-step, the switches are booted up and have no zoning information. You need to create the zones on the switches and add them to the zonesets.
Basic mode: When zones are in basic mode, refer to the sample command outputs below.
1.
Create zone and zoneset. Activate on Switch 1.
114
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Configuring and Managing Zones
Merge Process
Switch1# configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Switch1#(config)# vsan database
Switch1#(config-vsan-db)# vsan 100
Switch1#(config-vsan-db)# exit
Switch1#(config)# zone name zone1 vsan 100
Switch1#(config-zone)# member pwwn 11:11:11:11:11:11:11:1a
Switch1#(config-zone)# member pwwn 11:11:11:11:11:11:11:1b
Switch1#(config-zone)# exit
Switch1#(config)# zoneset name setA vsan 100
Switch1#(config-zoneset)# member zone1
Switch1#(config-zoneset)# exit
Switch1#(config)# zoneset activate name setA vsan 100
Zoneset activation initiated. check zone status
Switch1#(config)# exit
Switch1# show zoneset active vsan 100 zoneset name setA vsan 100 zone name zone1 vsan 100 pwwn 11:11:11:11:11:11:11:1a pwwn 11:11:11:11:11:11:11:1bSwitch1#
2.
Create zone and zoneset. Activate on Switch 2.
Switch2# configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Switch2#(config)# vsan database
Switch2#config-vsan-db)# vsan 100
Switch2#(config-vsan-db)# exit
Switch2#(config)# zone name zone2 vsan 100
Switch2#(config-zone)# member pwwn 22:22:22:22:22:22:22:2a
Switch2#(config-zone)# member pwwn 22:22:22:22:22:22:22:2b
Switch2#(config-zone)# exit
Switch2#(config)# zoneset name setB vsan 100
Switch2#(config-zoneset)# member zone2
Switch2#(config-zoneset)# exit
Switch2#(config)# zoneset activate name setB vsan 100
Zoneset activation initiated. check zone status
Switch2#(config)# exit
Switch2# show zoneset active vsan 100 zoneset name setB vsan 100 zone name zone2 vsan 100 pwwn 22:22:22:22:22:22:22:2a pwwn 22:22:22:22:22:22:22:2b
3.
Bring ISL link up and verify zone merge on Switch 1.
Switch1# configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Switch1(config)# interface fc1/5
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
115
Configuring and Managing Zones
Merge Process
Switch1(config-if)# no shutdown
Switch1(config-if)# exit
Switch1(config)# exit
Note Note Ensure that vsan 100 is allowed on ISL.
Switch1# show zoneset active vsan 100 zoneset name setB vsan 100 zone name zone1 vsan 100 pwwn 11:11:11:11:11:11:11:1a pwwn 11:11:11:11:11:11:11:1b
Switch1# show zoneset vsan 100 zoneset name setA vsan 100 zone name zone1 vsan 100 pwwn 11:11:11:11:11:11:11:1a pwwn 11:11:11:11:11:11:11:1b
4.
Bring ISL link up and verify zone merge on Switch 2.
Switch2# configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Switch2(config)# int fc2/5
Switch2(config-if)# no shut
Switch2(config-if)# exit
Switch2(config)# exit
Switch2# show zoneset active vsan 100 zoneset name setB vsan 100 zone name zone1 vsan 100 pwwn 11:11:11:11:11:11:11:1a pwwn 11:11:11:11:11:11:11:1b zone name zone2 vsan 100 pwwn 22:22:22:22:22:22:22:2a pwwn 22:22:22:22:22:22:22:2b
Switch2# show zoneset vsan 100zoneset name setB vsan 100 zone name zone2 vsan 100 pwwn 22:22:22:22:22:22:22:2a pwwn 22:22:22:22:22:22:22:2b
Note The name of the newly merged zoneset will be the name of the zoneset with alphabetically higher value. In the given example, the active zoneset is setB. To avoid future zoneset activation problems, the zone copy
active-zoneset full-zoneset vsan 100 command should be given, at this point on the switch. Examine if the command is given, and how the new zoning information is handled.
When the zone copy command is issued, it adds the learned zone information, zone 2 in this case, to the running configuration. If zone 2 has not been copied from residing in memory to copied into the running configuration, zone 2 information is not pushed back out.
116
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Configuring and Managing Zones
Merge Process
Note The zone copy command will delete all fcalias configuration.
Running-Configuration of Switch1 (before issuing the zone copy active-zoneset full-zoneset vsan 100 command).
Switch1# show run | b "Active Zone Database Section for vsan 100"
!Active Zone Database Section for vsan 100 zone name zone1 vsan 100 pwwn 11:11:11:11:11:11:11:1a pwwn 11:11:11:11:11:11:11:1b zone name zone2 vsan 100 pwwn 22:22:22:22:22:22:22:2a pwwn 22:22:22:22:22:22:22:2b zoneset name setB vsan 100 member zone1 member zone2 zoneset activate name setB vsan 100 do clear zone database vsan 100
!Full Zone Database Section for vsan 100 zone name zone1 vsan 100 pwwn 11:11:11:11:11:11:11:1a pwwn 11:11:11:11:11:11:11:1b zoneset name setA vsan 100 member zone1
Running-Configuration of Switch1 ( after issuing the "zone copy active-zoneset full-zoneset vsan 100" command)
Switch1# zone copy active-zoneset full-zoneset vsan 100
WARNING: This command may overwrite common zones in the full zoneset. Do you want to continue?
(y/n) [n] y
Switch1# show run | b "Active Zone Database Section for vsan 100"
!Active Zone Database Section for vsan 100 zone name zone1 vsan 100 pwwn 11:11:11:11:11:11:11:1a pwwn 11:11:11:11:11:11:11:1b zone name zone2 vsan 100 pwwn 22:22:22:22:22:22:22:2a pwwn 22:22:22:22:22:22:22:2b zoneset name setB vsan 100 member zone1 member zone2 zoneset activate name setB vsan 100 do clear zone database vsan 100
!Full Zone Database Section for vsan 100 zone name zone1 vsan 100 pwwn 11:11:11:11:11:11:11:1a pwwn 11:11:11:11:11:11:11:1b
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
117
Configuring and Managing Zones
Merge Process zone name zone2 vsan 100 pwwn 22:22:22:22:22:22:22:2a pwwn 22:22:22:22:22:22:22:2b zoneset name setA vsan 100 member zone1 zoneset name setB vsan 100 member zone1 member zone2
Running-Configuration of Switch2 ( before issuing the "zone copy active-zoneset full-zoneset vsan 100" command)
Switch2# show run | b "Active Zone Database Section for vsan 100"
!Active Zone Database Section for vsan 100 zone name zone2 vsan 100 pwwn 22:22:22:22:22:22:22:2a pwwn 22:22:22:22:22:22:22:2b zone name zone1 vsan 100 pwwn 11:11:11:11:11:11:11:1a pwwn 11:11:11:11:11:11:11:1b zoneset name setB vsan 100 member zone2 member zone1 zoneset activate name setB vsan 100 do clear zone database vsan 100
!Full Zone Database Section for vsan 100 zone name zone2 vsan 100 pwwn 22:22:22:22:22:22:22:2 apwwn 22:22:22:22:22:22:22:2b zoneset name setB vsan 100 member zone2
Running-Configuration of Switch2 ( after issuing the "zone copy active-zoneset full-zoneset vsan 100" command)
Switch2# zone copy active-zoneset full-zoneset vsan 100
WARNING: This command may overwrite common zones in the full zoneset. Do you want to continue?
(y/n) [n] y
Switch2# show run | b "Active Zone Database Section for vsan 100"
!Active Zone Database Section for vsan 100 zone name zone2 vsan 100 pwwn 22:22:22:22:22:22:22:2a pwwn 22:22:22:22:22:22:22:2b zone name zone1 vsan 100 pwwn 11:11:11:11:11:11:11:1a pwwn 11:11:11:11:11:11:11:1b zoneset name setB vsan 100 member zone2 member zone1 zoneset activate name setB vsan 100 do clear zone database vsan 100
!Full Zone Database Section for vsan 100
118
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Configuring and Managing Zones
Merge Process zone name zone2 vsan 100 pwwn 22:22:22:22:22:22:22:2a pwwn 22:22:22:22:22:22:22:2b zone name zone1 vsan 100 pwwn 11:11:11:11:11:11:11:1a pwwn 11:11:11:11:11:11:11:1b zoneset name setB vsan 10
0member zone2 member zone1
Referring back to the three entities of configuration, they are as follows on zone 1 before the zone merge:
• Saved configuration: nothing since zone information has not been saved by issuing the copy run start command.
• Running configuration: consists of zone 1.
• Configured and learned information: consists of zone 1.
After the zone merge, the entities are:
• Saved configuration: nothing has been saved.
• Running configuration: consists of zone 1.
• Configured and learned information: consists of zone 1 and zone 2.
Zone 2 has not become part of the running configuration. Zone 2 has been learned, and is in the active zoneset.
Only when the zone copy active-zoneset full-zoneset vsan 100 command is issued, zone 2 becomes copied from being learned to added to the running configuration. The configuration looks as follows after the command is issued:
Note The zone copy command will delete all fcalias configuration.
• Saved configuration: nothing has been saved.
• Running configuration: consists of zone 1 and zone 2.
• Configured and learned information: consists of zone 1 and zone 2.
Commands
By default zone in basic mode will only distribute active zoneset database only, this command was introduced in 1.0.4 SAN-OS will propagate active zoneset and full zoneset database:
zoneset distribute full vsan vsan_id
If the zone update or zoneset activation is going on, the above command must be explicitly enabled on each
VSAN on every switch.
Enhanced mode : When zones are in enhanced mode, refer to the sample command outputs below.
1.
Create zones and zoneset. Activate on Switch1.
Switch1# configure terminal
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
119
Configuring and Managing Zones
Merge Process
Enter configuration commands, one per line. End with CNTL/Z.
Switch1(config)# vsan database
Switch1(config-vsan-db)# vsan 200
Switch1(config-vsan-db)# zone mode enhanced vsan 200
WARNING: This command would distribute the zoning database of this switch throughout the fabric. Do you want to continue? (y/n) [n] y
Set zoning mode command initiated.
Check zone status
Switch1(config-vsan-db)# zone name zone1 vsan 200
Enhanced zone session has been created. Please 'commit' the changes when done.
Switch1(config-zone)# member pwwn 11:11:11:11:11:11:11:1a
Switch1(config-zone)# member pwwn 11:11:11:11:11:11:11:1b
Switch1(config-zone)# zoneset name SetA vsan 200
Switch1(config-zoneset)# member zone1
Switch1(config-zoneset)# zoneset activate name SetA vsan 200
Switch1(config)# zone commit vsan 200
Commit operation initiated. Check zone status
Switch1(config)# exit
Switch1# show zoneset activate vsan 200 zoneset name SetA vsan 200 zone name zone1 vsan 200 pwwn 11:11:11:11:11:11:11:1a pwwn 11:11:11:11:11:11:11:1b
Switch1# show zoneset vsan 200 zoneset name SetA vsan 200 zone name zone1 vsan 200 pwwn 11:11:11:11:11:11:11:1a pwwn 11:11:11:11:11:11:11:1b
2.
Create zones and zoneset. Activate on Switch2.
Switch2# configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Switch2(config)# vsan database
Switch2(config-vsan-db)# vsan 200
Switch2(config-vsan-db)# zone mode enhanced vsan 200
WARNING: This command would distribute the zoning database of this switch throughout the fabric. Do you want to continue? (y/n) [n] y
Set zoning mode command initiated. Check zone status
Switch2(config)# zone name zone2 vsan 200
Enhanced zone session has been created. Please 'commit' the changes when done.
Switch2(config-zone)# member pwwn 22:22:22:22:22:22:22:2a
Switch2(config-zone)# member pwwn 22:22:22:22:22:22:22:2b
Switch2(config-zone)# zoneset name SetB vsan 200
Switch2(config-zoneset)# member zone2
Switch2(config-zoneset)# zoneset act name SetB vsan 200
Switch2(config)# zone commit vsan 200
Commit operation initiated. Check zone status
Switch2(config)# exit
Switch2# show zoneset activate vsan 200 zoneset name SetB vsan 200 zone name zone2 vsan 200 pwwn 22:22:22:22:22:22:22:2a pwwn 22:22:22:22:22:22:22:2b
Switch2# show zoneset vsan 200 zoneset name SetB vsan 200 zone name zone2 vsan 200 pwwn 22:22:22:22:22:22:22:2a pwwn 22:22:22:22:22:22:22:2b
3.
Bring ISL link up and verify zone merge on Switch1.
120
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Configuring and Managing Zones
Merge Process
Switch1# configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Switch1(config)# interface fc4/1
Switch1(config-if)# no shutdown
Switch1(config-if)# exit
Switch1(config)# exit
Switch1(config-if)# show zoneset activate vsan 200 zoneset name SetB vsan 200 zone name zone1 vsan 200 pwwn 11:11:11:11:11:11:11:1a pwwn 11:11:11:11:11:11:11:1b zone name zone2 vsan 200 pwwn 22:22:22:22:22:22:22:2a pwwn 22:22:22:22:22:22:22:2b
Switch1(config-if)# show zoneset vsan 200 zoneset name SetA vsan 200 zone name zone1 vsan 200 pwwn 11:11:11:11:11:11:11:1a pwwn 11:11:11:11:11:11:11:1b zoneset name SetB vsan 200 zone name zone2 vsan 200 pwwn 22:22:22:22:22:22:22:2a pwwn 22:22:22:22:22:22:22:2b
Note Unlike basic mode, the entire zone database is merged in the case of enhanced mode, wherein Switch1 has the information of zonesets originally configured in Switch2 and vice versa.
4.
Bring ISL link up and verify zone merge on Switch2. After bringing up ISL between two switches:
Switch2# configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Switch2(config)# interface fc4/1
Switch2(config-if)# no shutdown
Switch2(config-if)# exit
Switch2(config)# exit
Switch2(config-zoneset)# show zoneset activate vsan 200 zoneset name SetB vsan 200 zone name zone2 vsan 200 pwwn 22:22:22:22:22:22:22:2a pwwn 22:22:22:22:22:22:22:2b zone name zone1 vsan 200 pwwn 11:11:11:11:11:11:11:1a pwwn 11:11:11:11:11:11:11:1b
Switch2(config-zoneset)# show zoneset vsan 200 zoneset name SetB vsan 200 zone name zone2 vsan 200 pwwn 22:22:22:22:22:22:22:2a pwwn 22:22:22:22:22:22:22:2b zoneset name SetA vsan 200 zone name zone1 vsan 200 pwwn 11:11:11:11:11:11:11:1a pwwn 11:11:11:11:11:11:11:1b
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
121
Configuring and Managing Zones
Analyzing a Zone Merge
5.
Execute the zone copy command for enhanced zone.
Switch 1
Switch1# zone copy active-zoneset full-zoneset vsan 200
WARNING: This command may overwrite common zones in the full zoneset. Do you want to continue? (y/n) [n] y
Switch1(config-if)# show zoneset activate vsan 200 zoneset name SetB vsan 200 zone name zone1 vsan 200 pwwn 11:11:11:11:11:11:11:1a pwwn 11:11:11:11:11:11:11:1b zone name zone2 vsan 200 pwwn 22:22:22:22:22:22:22:2a pwwn 22:22:22:22:22:22:22:2b
Switch1(config-if)# show zoneset vsan 200 zoneset name SetB vsan 200 zone name zone1 vsan 200 pwwn 11:11:11:11:11:11:11:1a pwwn 11:11:11:11:11:11:11:1b zone name zone2 vsan 200 pwwn 22:22:22:22:22:22:22:2a pwwn 22:22:22:22:22:22:22:2b
Switch 2
Switch2# zone copy active-zoneset full-zoneset vsan 200
WARNING: This command may overwrite common zones in the full zoneset. Do you want to continue? (y/n) [n] y
Switch2(config-zoneset)# show zoneset activate vsan 200 zoneset name SetB vsan 200 zone name zone2 vsan 200 pwwn 22:22:22:22:22:22:22:2a pwwn 22:22:22:22:22:22:22:2b zone name zone1 vsan 200 pwwn 11:11:11:11:11:11:11:1a pwwn 11:11:11:11:11:11:11:1b
Switch2(config-zoneset)# show zoneset vsan 200 zoneset name SetB vsan 200 zone name zone2 vsan 200 pwwn 22:22:22:22:22:22:22:2a pwwn 22:22:22:22:22:22:22:2b zone name zone1 vsan 200 pwwn 11:11:11:11:11:11:11:1a pwwn 11:11:11:11:11:11:11:1b
Analyzing a Zone Merge
To perform a zone merge analysis using DCNM SAN Client, follow these steps:
Step 1 Choose Zone > Merge Analysis .
You see the Zone Merge Analysis dialog box.
122
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Configuring and Managing Zones
Figure 42: Zone Merge Analysis Dialog Box
Configuring Zone Merge Control Policies
Step 2
Step 3
Step 4
Step 5
Step 6
Select the first switch to be analyzed from the Check Switch 1 drop-down list.
Select the second switch to be analyzed from the And Switch 2 drop-down list.
Enter the VSAN ID where the zone set merge failure occurred in the For Active Zoneset Merge Problems in VSAN Id field.
Click Analyze to analyze the zone merge.
Click Clear to clear the analysis data in the Zone Merge Analysis dialog box.
Configuring Zone Merge Control Policies
To configure merge control policies, follow these steps:
Step 1
Step 2
Step 3
Step 4 switch# configure terminal
Enters configuration mode.
switch(config)# zone merge-control restrict vsan 4
Configures a restricted merge control setting for this VSAN.
switch(config)# no zone merge-control restrict vsan 2
Defaults to using the allow merge control setting for this VSAN.
switch(config)# zone commit vsan 4
Commits the changes made to VSAN 4.
To configure merge control policies, refer to the Cisco MDS 9000 Series NX-OS Fabric Configuration Guide .
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
123
Configuring and Managing Zones
Preventing Zones From Flooding FC2 Buffers
Preventing Zones From Flooding FC2 Buffers
By using the zone fc2 merge throttle enable command you can throttle the merge requests that are sent from zones to FC2 and prevent zones from flooding FC2 buffers. This command is enabled by default. This command can be used to prevent any zone merge scalability problem when you have a lot of zones. Use the show zone status command to view zone merge throttle information.
Permitting or Denying Traffic in the Default Zone
To permit or deny traffic in the default zone, follow these steps:
Step 1
Step 2
Step 3
Step 4 switch# configure terminal
Enters configuration mode.
switch(config)# zone default-zone permit vsan 5
Permits traffic flow to default zone members.
switch(config)# no zone default-zone permit vsan 3
Denies traffic flow to default zone members and reverts to factory default.
switch(config)# zone commit vsan 5
Commits the changes made to VSAN 5.
Broadcasting a Zone
You can specify an enhanced zone to restrict broadcast frames generated by a member in this zone to members within that zone. Use this feature when the host or storage devices support broadcasting.
Note broadcast command is not supported from 5.x release onwards.
Table 10: Broadcasting Requirements , on page 124
identifies the rules for the delivery of broadcast frames.
Table 10: Broadcasting Requirements
Yes
No
Yes
Active
Zoning?
Contains data.
Broadcast Enabled?
Frames
Broadcast?
Yes
Yes
No
Empty.
Yes
Yes
No
Successful.
124
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Configuring and Managing Zones
Configuring System Default Zoning Settings
Tip If any NL port attached to an FL port shares a broadcast zone with the source of the broadcast frame, then the frames are broadcast to all devices in the loop.
To broadcast frames in the enhanced zoning mode, follow these steps:
Step 1
Step 2
Step 3
Step 4
Step 5
Step 6
Step 7
Step 8
Step 9 switch# configure terminal
Enters configuration mode.
switch(config)# zone-attribute-group name BroadcastAttr vsan 2
Configures the zone attribute group for the required VSAN.
switch(config)# no zone-attribute-group name BroadAttr vsan 1
Removes the zone attribute group for the required VSAN.
switch(config-attribute-group)# broadcast
Creates a broadcast attribute for this group and exits this submode.
switch(config-attribute-group)# no broadcast
Removes broadcast attribute for this group and exits this submode.
switch(config)# zone name BroadcastAttr vsan 2
Configures a zone named BroadcastAttr in VSAN 2.
switch(config-zone)# member pwwn 21:00:00:e0:8b:0b:66:56
Adds the specified members to this zone and exits this submode.
switch(config)# zone commit vsan 1
Applies the changes to the enhanced zone configuration and exits this submode.
switch# show zone vsan 1
Displays the broadcast configuration
Configuring System Default Zoning Settings
You can configure default settings for default zone policies, full zone distribution, and generic service permissions for new VSANs on the switch. To configure switch-wide default settings, follow these steps:
Step 1
Step 2 switch# configure terminal
Enters configuration mode.
switch(config)# system default zone default-zone permit
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
125
Configuring and Managing Zones
Configuring Zone Generic Service Permission Settings
Step 3
Step 4
Configures permit as the default zoning policy for new VSANs on the switch.
switch(config)# system default zone distribute full
Enables full zone database distribution as the default for new VSANs on the switch.
switch(config)# system default zone gs { read | read-write }
Configures read only or read-write (default) as the default generic service permission for new VSANs on the switch.
Note Since VSAN 1 is the default VSAN and is always present on the switch, the have no effect on VSAN 1.
system default zone commands
Configuring Zone Generic Service Permission Settings
Zone generic service permission setting is used to control zoning operation through generic service (GS) interface. The zone generic service permission can be read-only, read-write or none (deny).
To configure generic service (GS) settings, follow these steps:
Step 1
Step 2 switch# configure terminal
Enters configuration mode.
switch(config)# zone gs { read | read-write } vsan 3000
Configures gs permission value as read only or read-write in the specified VSAN.
Displaying Enhanced Zone Information
You can view any zone information by using the show command.
Displays the Active Zoneset Information for a Specified VSAN switch(config)# show zoneset active vsan 1 zoneset name qoscfg vsan 1 zone name qos1 vsan 1
* fcid 0xe80200 [pwwn 50:08:01:60:01:5d:51:11]
* fcid 0xe60000 [pwwn 50:08:01:60:01:5d:51:10]
* fcid 0xe80100 [pwwn 50:08:01:60:01:5d:51:13] zone name qos3 vsan 1
* fcid 0xe80200 [pwwn 50:08:01:60:01:5d:51:11]
* fcid 0xe60100 [pwwn 50:08:01:60:01:5d:51:12]
* fcid 0xe80100 [pwwn 50:08:01:60:01:5d:51:13] zone name sb1 vsan 1
* fcid 0xe80000 [pwwn 20:0e:00:11:0d:10:dc:00]
* fcid 0xe80300 [pwwn 20:0d:00:11:0d:10:da:00]
* fcid 0xe60200 [pwwn 20:13:00:11:0d:15:75:00]
* fcid 0xe60300 [pwwn 20:0d:00:11:0d:10:db:00]
126
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Configuring and Managing Zones
Displaying Enhanced Zone Information
Displays the ZoneSet Information or a Specified VSAN switch(config)# show zoneset vsan 1 zoneset name qoscfg vsan 1 zone name qos1 vsan 1 zone-attribute-group name qos1-attr-group vsan 1 pwwn 50:08:01:60:01:5d:51:11 pwwn 50:08:01:60:01:5d:51:10 pwwn 50:08:01:60:01:5d:51:13 zone name qos3 vsan 1 zone-attribute-group name qos3-attr-group vsan 1 pwwn 50:08:01:60:01:5d:51:11 pwwn 50:08:01:60:01:5d:51:12 pwwn 50:08:01:60:01:5d:51:13 zone name sb1 vsan 1 pwwn 20:0e:00:11:0d:10:dc:00 pwwn 20:0d:00:11:0d:10:da:00 pwwn 20:13:00:11:0d:15:75:00 pwwn 20:0d:00:11:0d:10:db:00
Displays the Zone Attribute Group Information for a Specified VSAN switch# show zone-attribute-group vsan 2 zone-attribute-group name $default_zone_attr_group$ vsan 2 read-only qos priority high broadcast zone-attribute-group name testattgp vsan 2 read-only broadcast qos priority high
Displays the fcalias Information for the Specified VSAN switch# show fcalias vsan 2 fcalias name testfcalias vsan 2 pwwn 21:00:00:20:37:39:b0:f4 pwwn 21:00:00:20:37:6f:db:dd pwwn 21:00:00:20:37:a6:be:2f
Displays the Zone Status for the Specified VSAN switch(config)# show zone status vsan 1
VSAN: 1 default-zone: deny distribute: active only Interop: default mode: basic merge-control: allow session: none hard-zoning: enabled broadcast: disabled smart-zoning: disabled rscn-format: fabric-address activation overwrite control:disabled
Default zone: qos: none broadcast: disabled ronly: disabled
Full Zoning Database :
DB size: 4 bytes
Zonesets:0 Zones:0 Aliases: 0
Active Zoning Database :
Database Not Available
Current Total Zone DB Usage: 4 / 2097152 bytes (0 % used)
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
127
Configuring and Managing Zones
Controlling Zoning Configuration Sessions
Pending (Session) DB size:
Full DB Copy size: n/a
Active DB Copy size: n/a
SFC size: 4 / 2097152 bytes (0 % used)
Status:
Displays the Pending ZoneSet Information for the VSAN to be Committed switch# show zoneset pending vsan 2
No pending info found
Displays the Pending Zone Information for the VSAN to be Committed switch# show zone pending vsan 2
No pending info found
Displays the Pending Zone Information for the VSAN to be Committed switch# show zone-attribute-group pending vsan 2
No pending info found
Displays the Pending Active ZoneSet Information for the VSAN to be Committed switch# show zoneset pending active vsan 2
No pending info found
Displays the Difference Between the Pending and Effective Zone Information for the Specified VSAN switch# show zone pending-diff vsan 2 zone name testzone vsan 2
member pwwn 21:00:00:20:37:4b:00:a2
+ member pwwn 21:00:00:20:37:60:43:0c
Exchange Switch Support (ESS) defines a mechanism for two switches to exchange various supported features.
Displays the ESS Information for All Switches in the Specified VSAN switch# show zone ess vsan 2
ESS info on VSAN 2 :
Domain : 210, SWWN : 20:02:00:05:30:00:85:1f, Cap1 : 0xf3, Cap2 : 0x0
Displays the Pending fcalias Information for the VSAN to be Committed switch# show fcalias pending vsan 2
No pending info found
Controlling Zoning Configuration Sessions
In enhanced mode zoning, the switch in which a zoning session is started takes the fabric wide zoning configuration lock for the VSAN. This configuration lock prevents users on other switches in the fabric from
128
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Configuring and Managing Zones
Configuring Zoning Session Limit making simultaneous, and possibly conflicting, configuration changes. However, by default, the same user is allowed to login multiple times on the switch where the configuration is locked and start multiple zoning configuration sessions. This also may result in conflicting or undesired zone configuration.
The single session option enforces a maximum of one zoning configuration session per VSAN at a time on the switch with the zone configuration fabric lock. This limit causes the switch to disallow any new zoning configuration sessions to be started in the same VSAN. This limit also applies to any configuration source such as another user, Cisco DCNM, or NX-API.
Note • If the login session is disconnected for some reason, such as after a supervisor switchover, the zone session remains with the fabric wide lock and any pending changes. In this case, when the single session option is enabled, no further zone configuration from any other login to the switch will be allowed.
Attempts to do so will be rejected with an error message displaying the old session owner information.
This information can also be viewed using the show zone status command. To recover, the session lock must be cleared using the clear zone lock command from the switch where the session got locked.
Clearing the session lock will delete any pending zoning configuration and the zone configuration changes will have to be reentered. Use the show zone pending-diff command to display any pending zoning configuration changes prior to clearing the zone lock.
• This option is available from Cisco MDS NX-OS Release 8.4(2).
• Ensure that you disable this option before downgrading to any earlier NX-OS release. Otherwise, the downgrade process will fail.
Configuring Zoning Session Limit
To configure zoning session limit in a VSAN, follow these steps:
Step 1
Step 2
Step 3 switch# configure terminal
Enters configuration mode.
switch(config)# zone mode enhanced vsan id single-session
Enables the single session option in the specified VSAN.
switch(config)# no zone mode enhanced vsan id single-session
Disables the single session option in the specified VSAN and leaves the VSAN in enhanced zoning mode.
Compacting the Zone Database for Downgrading
Prior to Cisco SAN-OS Release 6.2(7), only 8000 zones are supported per VSAN. If you add more than 8000 zones to a VSAN, a configuration check is registered to indicate that downgrading to a previous release could cause you to lose the zones over the limit. To avoid the configuration check, delete the excess zones and compact the zone database for the VSAN. If there are 8000 zones or fewer after deleting the excess zones, the compacting process assigns new internal zone IDs and the configuration can be supported by Cisco
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
129
Configuring and Managing Zones
Zone and ZoneSet Analysis
SAN-OS Release 6.2(5) or earlier. Perform this procedure for every VSAN on the switch with more than
8000 zones.
Note A merge failure occurs when a switch supports more than 8000 zones per VSAN but its neighbor does not.
Also, zoneset activation can fail if the switch has more than 8000 zones per VSAN and not all switches in the fabric support more than 8000 zones per VSAN.
To delete zones and compact the zone database for a VSAN, follow these steps:
Step 1
Step 2
Step 3 switch# configure terminal
Enters configuration mode.
switch(config)# no zone name ExtraZone vsan 10
Deletes a zone to reduce the number of zones to 8000 or fewer.
switch(config)# zone compact vsan 10
Compacts the zone database for VSAN 10 to recover the zone ID released when a zone was deleted.
To compact the zone database for downgrading, refer to the Cisco MDS 9000 Series NX-OS Fabric Configuration Guide .
Zone and ZoneSet Analysis
To better manage the zones and zone sets on your switch, you can display zone and zoneset information using the show zone analysis command.
Full Zoning Analysis switch# show zone analysis vsan 1
Zoning database analysis vsan 1
Full zoning database
Last updated at: 15:57:10 IST Feb 20 2006
Last updated by: Local [ CLI ]
Num zonesets: 1
Num zones: 1
Num aliases: 0
Num attribute groups: 0
Formattted size: 36 bytes / 2048 Kb
Unassigned Zones: 1 zone name z1 vsan 1
Note The maximum size of the full zone database per VSAN is 4096 KB.
Active Zoning Database Analysis
130
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Configuring and Managing Zones
Zone and ZoneSet Analysis switch(config-zone)# show zone analysis active vsan 1
Zoning database analysis vsan 1
Active zoneset: qoscfg
Activated at: 14:40:55 UTC Mar 21 2014
Activated by: Local [ CLI ]
Default zone policy: Deny
Number of devices zoned in vsan: 8/8 (Unzoned: 0)
Number of zone members resolved: 10/18 (Unresolved: 8)
Num zones: 4
Number of IVR zones: 0
Number of IPS zones: 0
Formatted size: 328 bytes / 4096 Kb
Note The maximum size of the zone database per VSAN is 4096 KB.
ZoneSet Analysis switch(config-zone)# show zone analysis zoneset qoscfg vsan 1
Zoning database analysis vsan 1
Zoneset analysis: qoscfg
Num zonesets: 1
Num zones: 4
Num aliases: 0
Num attribute groups: 1
Formatted size: 480 bytes / 4096 Kb
Displays the Zone Status switch(config-zone)# show zone status
VSAN: 1 default-zone: deny distribute: active only Interop: default mode: basic merge-control: allow session: none hard-zoning: enabled broadcast: disabled smart-zoning: disabled rscn-format: fabric-address activation overwrite control:disabled
Default zone: qos: none broadcast: disabled ronly: disabled
Full Zoning Database :
DB size: 4 bytes
Zonesets:0 Zones:0 Aliases: 0
Active Zoning Database :
Database Not Available
Current Total Zone DB Usage: 4 / 2097152 bytes (0 % used)
Pending (Session) DB size:
Full DB Copy size: n/a
Active DB Copy size: n/a
SFC size: 4 / 2097152 bytes (0 % used)
Status:
VSAN: 8 default-zone: deny distribute: full Interop: default mode: basic merge-control: allow session: none hard-zoning: enabled broadcast: disabled smart-zoning: disabled rscn-format: fabric-address
Default zone:
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
131
Configuring and Managing Zones
Zone and ZoneSet Analysis qos: none broadcast: disabled ronly: disabled
Full Zoning Database :
DB size: 1946498 bytes
Zonesets:6 Zones:8024 Aliases: 0
Active Zoning Database :
DB size: 150499 bytes
Name: zoneset-1000 Zonesets:1 Zones:731
Current Total Zone DB Usage: 2096997 / 2097152 bytes (99 % used)
Pending (Session) DB size:
Full DB Copy size: n/a
Active DB Copy size: n/a
SFC size: 2096997 / 2097152 bytes (99 % used)
Status: Zoneset distribution failed [Error: Fabric changing Dom 33]: at 17:05:06 UTC Jun 16 2014
VSAN: 9 default-zone: deny distribute: full Interop: default mode: enhanced merge-control: allow session: none hard-zoning: enabled broadcast: enabled smart-zoning: disabled rscn-format: fabric-address
Default zone: qos: none broadcast: disabled ronly: disabled
Full Zoning Database :
DB size: 2002584 bytes
Zonesets:4 Zones:7004 Aliases: 0 Attribute-groups: 1
Active Zoning Database :
DB size: 94340 bytes
Name: zoneset-hac13-200 Zonesets:1 Zones:176
Current Total Zone DB Usage: 2096924 / 2097152 bytes (99 % used)
Pending (Session) DB size:
Full DB Copy size: 0 bytes
Active DB Copy size: 0 bytes
SFC size: 0 / 2097152 bytes (0 % used)
Status: Activation completed at 17:28:04 UTC Jun 16 2014
VSAN: 12 default-zone: deny distribute: full Interop: default mode: enhanced merge-control: allow session: none hard-zoning: enabled broadcast: enabled smart-zoning: disabled rscn-format: fabric-address
Default zone: qos: none broadcast: disabled ronly: disabled
Full Zoning Database :
DB size: 84 bytes
Zonesets:0 Zones:1 Aliases: 0 Attribute-groups: 1
Active Zoning Database :
DB size: 144 bytes
Name: zs1 Zonesets:1 Zones:2
Current Total Zone DB Usage: 228 / 2097152 bytes (0 % used)
Pending (Session) DB size:
Full DB Copy size: 0 bytes
Active DB Copy size: 0 bytes
SFC size: 0 / 2097152 bytes (0 % used)
Status: Commit completed at 14:39:33 UTC Jun 27 201
Displaying the System Defalult Zone switch(config)# show system default zone system default zone default-zone deny system default zone distribute active only system default zone mode basic system default zone gs read-write system default zone smart-zone disabled
132
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Configuring and Managing Zones
Zoning Best Practice
See the Cisco MDS 9000 Series Command Reference for the description of the information displayed in the command output.
Zoning Best Practice
A Cisco Multilayer Director Switch (MDS) uses a special kind of memory called Ternary Content Addressable
Memory (TCAM) on its Fibre Channel (FC) linecards. This special memory provides an Access Control List
(ACL) type of function for Cisco MDS. The process that controls this functionality is called the ACLTCAM.
The E/TE ports (Inter Switch Links - ISLs) and F (Fabric) ports have their own programming, which is unique to their respective port types.
TCAM Regions
TCAM is divided into several regions of various sizes. The main regions and the type of programming contained in each region are described in
Table 11: TCAM Regions , on page 133
:
Table 11: TCAM Regions
Region
Region 1 - TOP SYS
Programming Type
Fabric-Login, Port-Login, Diagnostics features (10%-20%)
Region 2 - SECURITY Security, Interop-Mode-4 features, IVR ELS capture (5%-10%)
Region 3 - Zoning
Region 4 - Bottom
Zoning features, including IVR and SAN Analytics (50%-75%)
PLOGI,ACC, and FCSP trap, ISL, ECHO-permit (10%-20%)
2
When a hard-zoning failure occurs, Region 4 (bottom region) is used to program wildcard entries to allow any-to-any communication.
TCAM regions are automatically configured and cannot be changed. TCAM is allocated on a per-module and per-forwarding engine (fwd-eng) basis.
TCAM space on MDS 9148S and MDS 9250i fabric switches is significantly less than that on the director-class
Fibre Channel modules and newer fabric switches such as MDS 9396S, MDS 9132T, and the switches that will be launched in the future.
When a port comes online, some amount of basic programming is needed on that port. This programming differs according to the port type. This basic programming is minimal and does not consume many TCAM entries. Typically, programming is performed on inputs such that frames entering the switch are subject to this programming and frames egressing the switch are not.
ACL TCAM Alerting
Starting from Cisco MDS NX-OS Release 8.3(1), ACL TCAM usage alerting syslog messages were introduced on all Cisco MDS switches except on Cisco MDS 9148S and MDS 9250i switches. From Cisco MDS NX-OS
Release 8.3(2), ACL TCAM usage alerting syslog messages were introduced on Cisco MDS 9148S and MDS
9250i switches.
• When the TCAM usage crosses 80% in the module, direction, region, and forwarding engine listed, the following system message is generated. This system message does not indicate that TCAM was exhausted or any TCAM programming failed.
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
133
Configuring and Managing Zones
Zoning Types
%ACLTCAM-SLOT1-4-REGION_RISING_THRESHOLD: ACL (region) (input | output) region usage
(num of in use entries of total entries) exceeded 80% on forwarding engine (num)
• When TCAM usage falls below the 80% threshold in the module, region, direction, and forwarding engine indicated, the following system message is generated. This system message does not indicate that
TCAM was exhausted or any TCAM programming failed.
%ACLTCAM-SLOT1-4-REGION_FALLING_THRESHOLD: ACL (region) (input | output) region usage
(num of in use entries of total entries) fell below 80% on forwarding engine (num)
• When the overall TCAM usage indicated in the forwarding engine crosses 60% in the module, direction, and forwarding engine indicated, the following system message is generated:
%ACLTCAM-SLOT1-4-TOTAL_RISING_THRESHOLD: ACL total (input | output) usage (num of in use entries of total entries) exceeded 60% on forwarding engine (num)
• When the overall TCAM usage indicated in the forwarding engine falls below 60% in the module, direction, and forwarding engine indicated, the following system message is generated:
%ACLTCAM-SLOT1-4-TOTAL_FALLING_THRESHOLD: ACL total (input | output) usage (num of in use entries of total entries) fell below 60% on forwarding engine (num)
Use the show system internal acl tcam-usage command to display the ACLTCAM usage except for Cisco
MDS 9148S and MDS 9250i switches. For Cisco MDS 9148S and MDS 9250i switches, use the show system internal acltcam-soc tcam-usage command.
If you see the TCAM usage alerting syslog messages, the zoning, port-channel port allocation, and analytics configurations may need to be investigated. If TCAM usage reaches 100%, it is likely that some devices will not be able to communicate with other devices that they are zoned with. Follow the recommendations listed in this section to reduce the TCAM usage.
Zoning Types
The Cisco MDS platform uses two types of zoning - 'Hard' and 'Soft' zoning.
Soft zoning - In this mode only control plane traffic is policed by the switch supervisor services. In particular, the Fibre Channel Name Server (FCNS) will limit the list of permitted devices in an FCNS reply to only those that are in the zone configuration. However, the end device data plane traffic is unpoliced. This means a rogue end device may connect to other devices it is not zoned with.
Hard zoning - In this mode both control plane and data plane traffic are policed. Control plane traffic is policed by the switch supervisor and data plane traffic is policed on each ingress port with hardware assistance. The policing rules are set by the zoneset which programmed into each linecard. The destination of each frame is checked by hardware and, if it is not permitted by zoning, it is dropped. In this mode any device can only communicate with end devices it is authorized to.
By default, both types of zoning are enabled, with hard zoning used in priority over soft zoning. In the event that the system is unable to use hard zoning due to hardware resource exhaustion it will be disabled and the system will fall back to use soft zoning
The following example shows how Cisco MDS programs TCAM on a port:
134
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Configuring and Managing Zones
Zoning Types
The following example shows a zone in the active zone set for a VSAN. This is the basic programming that exists on an interface because of Hard zoning.
zone1 member host (FCID 0x010001) member target1 (FCID 0x010002)
In such a scenario, the following is the ACL programming: fc1/1 - Host interface
Entry#
1
1
2
Source ID
010001
Mask ffffff
2 000000 fc1/2 - Target1 interface
000000
Entry# Source ID Mask
010002
000000 ffffff
000000
Destination ID
010002(target1)
000000
Destination ID
010001(Host)
000000
Mask ffffff
000000
Mask ffffff
000000
Action
Permit
Drop
Action
Permit
Drop
Note In addition to what is provided here, additional programming exists. Moreover, any TCAM table is ended by a drop-all entry.
The mask indicates which parts of the FCIDs are matched with the input frame. So, when there is a mask
0xffffff, the entire FCID is considered when matching it to the ACL entry. If the mask is 0x000000, none of it is considered because, by default, it will match all the FCIDs.
In the above programming example, note that when a frame is received on fc1/1, and if it has a source ID(FCID) of 0x010001(the host) and a destination ID(FCID) of 0x010002(Target1), it will be permitted and routed to the destination. If it is any other end-to-end communication, it will be dropped.
The following example shows another scenario where zoning is changed: zone1 member host (FCID 010001) member target1 (FCID 010002) member target2 (FCID 010003) member target3 (FCID 010004)
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
135
Configuring and Managing Zones
Zoning Types
In such a scenario, the following is the ACL programming: fc1/1 Host interface
Entry#
1
Source ID
010001
Mask ffffff
2
3
4
010001
010001
000000 ffffff ffffff
000000 fc1/2 - Target1 interface
Entry# Source ID Mask
1
2
3
010002
010002
010002 ffffff ffffff ffffff
4 000000 fc1/3 - Target2 interface
000000
3
4
Entry#
1
2
Source ID
010003
010003
010003
000000
Mask ffffff ffffff ffffff
000000
2
3
4 fc1/4 - Target3 interface
Entry# Source ID Mask
1 010004 ffffff
010004
010004
000000 ffffff ffffff
000000
Destination ID
010002(target1)
010003(target2)
010004(target3)
000000
Destination ID
010001(host)
010003(target2)
010004(target3)
000000
Destination ID
010001(host)
010002(target1)
010004(target3)
000000
Destination ID
010001(host)
010002(target1)
010003(target2)
000000
Mask Action ffffff Permit ffffff Permit ffffff Permit
000000 Drop
Mask Action ffffff Permit ffffff Permit ffffff Permit
000000 Drop
Mask Action ffffff Permit ffffff Permit ffffff Permit
000000 Drop
Mask Action ffffff Permit ffffff Permit ffffff Permit
000000 Drop
The above example demonstrates that the number of TCAM entries consumed by a zone (N) is equal to
N*(N-1). So, a zone with four members would have used a total of 12 TCAM entries (4*3 = 12). Note the drop-all entry does not count against the N*(N-1) rule.
The above example shows two entries in each of the target interfaces (fc1/2-fc1/4) that are probably not needed since it is usually not advantageous to zone multiple targets together. For example, in fc1/2, there is an entry that permits Target1 to communicate with Target2, and an entry that permits Target1 to communicate with
Target3.
As these entries are not needed and could even be detrimental, they should be avoided. You can avoid the addition of such entries by using single-initiator or single-target zones (or use Smart Zoning).
Note If the same two devices are present in more than one zone in a zone set, TCAM programming will not be repeated.
The following example shows a zone that is changed to three separate zones: zone1 member host (FCID 010001) member target1 (FCID 010002) zone2 member host (FCID 010001) member target2 (FCID 010003) zone3 member host (FCID 010001) member target3 (FCID 010004)
In such a scenario, the following is the ACL programming: fc1/1 - Host interface - This would look the same
Entry# Source ID Mask Destination ID Mask Action
136
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Configuring and Managing Zones
Forwarding Engines
3
4
1
2
010001
010001
010001
000000 ffffff ffffff ffffff
000000 fc1/2 - Target1 interface
Entry# Source ID Mask
1 010002 ffffff
2 000000 fc1/3 - Target2 interface
000000
Entry#
1
2
Source ID
010003
000000
Mask ffffff
000000
1
2 fc1/4 - Target3 interface
Entry# Source ID Mask
010004
000000 ffffff
000000
010002(target1)
010003(target2)
010004(target3)
000000
Destination ID
010001(host)
000000
Destination ID
010001(host)
000000
Destination ID
010001(host)
000000 ffffff Permit ffffff Permit ffffff Permit
000000 Drop
Mask Action ffffff Permit
000000 Drop
Mask Action ffffff Permit
000000 Drop
Mask Action ffffff Permit
000000 Drop
Note that in the above example, the target-to-target entries are not found, and that six of the 12 entries are no longer programmed. This results in lesser use of TCAM and better security (only the host can communicate with the three targets, and the targets themselves can communicate only with one host, and not with each other).
Forwarding Engines
A Cisco Multilayer Director Switch (MDS) uses a special kind of memory called Ternary Content Addressable
Memory (TCAM) on its Fibre Channel modules. This special memory provides an Access Control List (ACL) type of function for Cisco MDS. The process that controls this functionality is called ACLTCAM. The E or
TE ports (ISLs) and F (Fabric) ports have their own programming that is unique to their respective port types.
TCAM is allocated to individual forwarding engines and forwarding engines are assigned a group of ports.
Director-class Fibre Channel modules have more TCAM space than fabric switches. The number of forwarding engines, the ports assigned to each forwarding engine, and the amount of TCAM allocated to each forwarding engine is hardware dependent.
The following example shows an output from Cisco MDS 9148S: switch# show system internal acltcam–soc tcam–usage
TCAM Entries:
=============
Mod Fwd Dir
Region1 Region2
TOP SYS SECURITY
Region3
ZONING
Region4 Region5 Region6
BOTTOM FCC DIS FCC ENA
Eng Use/Total Use/Total Use/Total Use/Total Use/Total Use/Total
––– ––– –––––– –––––––––– ––––––––– –––––––––––– ––––––––– ––––––––– –––––––––
1 1 INPUT 19/407 1/407 1/2852 * 4/407 0/0 0/0
1 1
1 2
OUTPUT
INPUT
0/25
19/407
0/25
1/407
0/140
0/2852 *
0/25
4/407
0/12
0/0
1/25
0/0
1 2
1 3
1 3
OUTPUT
INPUT
OUTPUT
0/25
19/407
0/25
0/25
1/407
0/25
0/140
0/2852 *
0/140
–––––––––––––––––––––––––––––––––––––––––––––––––––
* 1024 entries are reserved for LUN Zoning purpose.
0/25
4/407
0/25
0/12
0/0
0/12
1/25
0/0
1/25
The above example indicates the following:
• There are three forwarding engines, 1 through 3.
• Since there are 48 ports on Cisco MDS 9148 switches, each forwarding engine handles 16 ports.
• Each forwarding engine has 2852 entries in region 3 (the zoning region) for input. This is the main region used, and consequently, has the largest amount of available entries.
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
137
Configuring and Managing Zones
Forwarding Engines
• Forwarding engine 3 has only one entry that is currently in use out of the total 2852 in the zoning region.
The following example shows the output from Cisco MDS 9710 switch with a 2/4/8/10/16 Gbps Advanced
Fibre Channel Module (DS–X9448–768K9):
F241–15–09–9710–2# show system internal acl tcam–usage
TCAM Entries:
=============
Mod Fwd Dir
Region1 Region2
TOP SYS SECURITY
Region3
ZONING
Region4 Region5 Region6
BOTTOM FCC DIS FCC ENA
Eng Use/Total Use/Total Use/Total Use/Total Use/Total Use/Total
––– ––– –––––– –––––––––– ––––––––– –––––––––––– ––––––––– ––––––––– –––––––––
1 0
1 0
1 1
1 1
1 2
INPUT
OUTPUT
INPUT
OUTPUT
INPUT
55/19664
13/4075
52/19664
7/4078
34/19664
0/9840
0/1643
0/9840
0/1646
0/9840
0/49136*
0/11467
2/49136*
0/11470
0/49136*
17/19664
0/4075
14/19664
0/4078
10/19664
0/0
6/1649
0/0
6/1652
0/0
0/0
21/1664
0/0
5/1651
0/0
1
1
1
1
1
1
1
...
2
3
3
4
4
5
5
OUTPUT
INPUT
OUTPUT
INPUT
OUTPUT
INPUT
OUTPUT
5/4078
34/19664
5/4078
34/19664
5/4078
34/19664
5/4078
0/1646
0/9840
0/1646
0/9840
0/1646
0/9840
0/1646
0/11470 0/4078
0/49136* 10/19664
0/11470 0/4078
0/49136* 10/19664
0/11470 0/4078
0/49136* 10/19664
0/11470 0/4078
6/1652
0/0
6/1652
0/0
6/1652
0/0
6/1652
1/1647
0/0
1/1647
0/0
1/1647
0/0
1/1647
The above example indicates the following:
• There are six forwarding engines, 0 through 5.
• Since there are 48 ports on a Cisco MDS DS–X9448–768K9 module, each forwarding engine handles eight ports.
• Each forwarding engine has 49136 entries in region 3 (the zoning region) for input. This is the main region that is used, and consequently, has the largest amount of available entries.
• Forwarding engine 2 has only two entries that are currently in use out of the total 49136 in the zoning region.
Note The commands that are used to view TCAM usage on fabric switches are different from the ones used for director–class switches. For MDS 9148, MDS 9148S, and MDS 9250i fabric switches, use the show system internal acltcam-soc tcam-usage command. For director class switches, MDS 9396S, and 32 Gbps fabric switches, use the show system internal acl tcam-usage command.
The following table provides information about ports to forwarding engines mapping:
Table 12: Ports to Forwarding Engines Mapping
Switch or Module
MDS 9132T
Forwarding
Engines
Port Ranges
2 1–16
17–32
0
1
Forwarding
Engine Number
Zoning Region
Entries
Bottom Region
Entries
49136
49136
19664
19664
138
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Configuring and Managing Zones
Forwarding Engines
Switch or Module
MDS 9148
MDS 9148S
MDS 9148T
MDS 9250i
Forwarding
Engines
Port Ranges
3 fc1/25–36 and fc1/45–48 fc1/5–12 and fc1/37–44
2
Forwarding
Engine Number
Zoning Region
Entries
Bottom Region
Entries
1 2852 407
2852 407
2852 407
3
3
4 fc1–4 and fc1/13–24 fc1/1–16 fc1/17–32 fc1/33–48
1–16
17–32
33–48 fc1/5–12 and eth1/1–8
3 fc1/1–4, fc1/13–20, and fc1/37–40
2 fc1/21–36 ips1/1–2
3
4
2
1
0
1
1
2
3
2852
2852
2852
49136
49136
49136
2852
2852
2852
2852
407
407
407
19664
19664
19664
407
407
407
407
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
139
Configuring and Managing Zones
Forwarding Engines
Switch or Module
MDS 9396S
MDS 9396T
DS–X9248–48K9
DS–X9248–96K9
DS–X9224–96K9
DS–X9232–256K9
1
2
2
4
13–24
1–8
9–16
17–24
25–32
33–48
49–64
65-80
81-96
1–48
1–24
25–48
1–12
Forwarding
Engines
Port Ranges
12 fc1/1–8 fc1/9–16 fc1/17–24 fc1/25–32 fc1/33–40 fc1/41–48
6 fc1/49–56 fc1/57–64 fc1/65–72 fc1/73–80 fc1/81–88 fc1/89–96
1–16
17–32
27168
27168
27168
27168
49136
49136
49136
49136
49136
49136
49136
49136
49136
49136
49136
49136
27168
1
2
1
0
1
0
0
0
3
4
5
2
3
0
1
10
11
8
9
6
7
4
5
2
3
0
1
Forwarding
Engine Number
Zoning Region
Entries
Bottom Region
Entries
49136
49136
19664
19664
49136
49136
49136
49136
49136
49136
49136
49136
19664
19664
19664
19664
19664
19664
19664
19664
2680
2680
2680
2680
19664
19664
19664
19664
19664
19664
19664
19664
19664
19664
19664
19664
2680
140
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Configuring and Managing Zones
F, TF, NP, and TNP Port Channels
Switch or Module
DS–X9248–256K9
DS–X9448–768K9
DS–X9334–K9
DS–X9648–1536K9
Forwarding
Engines
Port Ranges
4 1–12
13–24
6
25–36
37–48
1–8
9–16
3
3
17–24
25–32
33–40
41–48
1–8
9–16
17–24
1–16
17–32
33–48
2
0
0
1
1
2
4
5
2
3
0
1
2
3
0
1
Forwarding
Engine Number
Zoning Region
Entries
Bottom Region
Entries
49136
49136
19664
19664
49136
49136
49136
49136
19664
19664
19664
19664
49136
49136
49136
49136
49136
49136
49136
49136
49136
49136
19664
19664
19664
19664
19664
19664
19664
19664
19664
19664
F, TF, NP, and TNP Port Channels
Note We do not recommend using interface, fWWN, or domain-ID based zoning for devices that are connected to the edge Cisco N-Port Virtualization (NPV) switches.
F port channels provide fault tolerance and performance benefits on connections to N-Port Virtualization
(NPV) switches, including Cisco UCS Fabric Interconnects (FIs). F port channels present unique challenges to ACL TCAM programming. When F ports are aggregated into a port channel, ACL TCAM programming is repeated on each member interface. Consequently, these types of port channels multiply the amount of
TCAM entries needed. Because of this, it is imperative that the member interfaces are allocated as optimally as possible, and that zoning best practices are also followed. If you also consider the fact that these F port channels can contain 100+ host logins, TCAM can easily be exceeded, especially for fabric switches if best practices are not followed.
The following is a sample topology:
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
141
Configuring and Managing Zones
E and TE Port Channels and IVR
This example assumes that the port channel (PC) contains 8 interfaces, fc1/1-fc1/8.
In addition, the following two zones are active: zone1 member host (host 0x010001) member target1 (target1 0x010002) zone2 member host (host 0x010001) member target2 (target2 0x010003)
In such a scenario, the following ACL programming will be present on each member of the PC: fc1/1(through fc1/8) (port-channel)
Entry#
1
2
3
Source ID
010001
010001
000000
Mask ffffff ffffff
000000
Destination ID
010002(target1)
010003(target2)
000000
Mask ffffff ffffff
000000
Action
Permit
Permit
Drop
The above example shows the ACL TCAM programming that will be duplicated on each member of the F port-channel. Consequently, if a lot of programming is required because of a large number of FLOGIs on the
F port channel, or a large number of devices are zoned with the devices on the F port channel, TCAM can be exhausted on a forwarding engine. The following are the best practices for efficient use of TCAM with respect to F ports and F port-channels:
• Distribute port-channel member interfaces into different forwarding engines, especially on fabric switches.
• If TCAM usage is still too high in the case of port-channel with a large number of interfaces, then split the port-channel into two separate port-channels each with half the interfaces. This will still provide redundancy but will reduces the number of FLOGIs per individual port-channel and thus reduce TCAM usage.
• Distribute member interfaces into different linecards on director-class switches.
• Distribute member interfaces into forwarding engines with lower TCAM zoning region usage.
• Use single-initiator zones, single-target zones, or Smart Zoning.
E and TE Port Channels and IVR
E port channels provide Inter Switch Links (ISLs) between fabric switches. Typically, there is minimal TCAM programming on these types of interfaces. Therefore, besides placing them into different linecards, and perhaps port groups on director-class switches, there is a little more to be done. However, when the Inter VSAN
Routing (IVR) feature is being deployed, extensive TCAM programming can exist on ISLs because the IVR topology transitions from one VSAN to another. Consequently, most of the considerations that apply on F/TF port channels will be applicable here too.
The following is an example of a topology:
142
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Configuring and Managing Zones
E and TE Port Channels and IVR
In this topology:
• Both Cisco MDS 9148S-1 and MDS 9148S-2 are in the IVR VSAN topology:
MDS9148S-1 vsan 1 and vsan 2
MDS9148S-2 vsan 2 and vsan 3
• IVR NAT is configured.
• VSAN 2 is the transit VSAN.
FCIDs per VSAN:
Host
Target1
VSAN 1 VSAN 2 VSAN 3
010001 210001 550002
440002 360002 030001
Note Domains 0x44 in VSAN 1, 0x21 and 0x36 in VSAN 2, and 0x55 in VSAN 3 are virtual domains created by
IVR NAT.
• The following is the IVR zoning topology: ivr zone zone1 member host vsan 1 member target1 vsan3
• The following is the ACL TCAM programming for the IVR zoning topology:
MDS9148S-1 fc1/1(Host) - VSAN 1
Entry#
1
Source ID
010001(host)
Mask ffffff
Destination ID
440002(target1)
- Forward to fc1/2
- Rewrite the following information:
VSAN to 2
Source ID to 210001
Destination ID to 360002
2 000000 000000
MDS9148S-1 fc1/2(ISL) - VSAN 2
Entry#
1
Source ID
360002(Target1)
- Forward to fc1/2
000000
Mask ffffff
Destination ID
210001(host)
Source ID to 440002
Destination ID to 010001
MDS9148S-2 fc1/2(ISL) - VSAN 2
Entry#
1
- Rewrite the following information:
VSAN to 1
Source ID
210001(host)
- Forward to fc1/2
Mask ffffff
Destination ID
360002(target1)
Mask ffffff
000000 Drop
Mask Action ffffff Permit
Mask ffffff
Action
Permit
Action
Permit
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
143
Configuring and Managing Zones
E and TE Port Channels and IVR
- Rewrite the following information:
VSAN to 3
Source ID to 550002
Destination ID to 030001
MDS9148S-2 fc1/1(Target1) - VSAN 3
Entry#
1
Source ID
030001(Target1)
Mask ffffff
Destination ID
550002(host)
- Forward to fc1/2
- Rewrite the following information:
2
VSAN to 2
Source ID to 360002
Destination ID to 210001
000000 000000 000000
Mask Action ffffff Permit
000000 Drop
Note Besides the entries in this example, there are other entries that IVR adds to capture important frames such as
PLOGIs, PRILIs, and ABTS.
The programming on the host and target1 ports is similar to the way it is without IVR, except that the FCIDs and VSANs are explicitly forwarded to an egress port and are rewritten to values that are appropriate for the transit VSAN (VSAN 2). These forwarding and rewrite entries are separate and are not included in the
TCAM-usage values.
However, now, on the ISLs in both the switches, programming that did not exist earlier is present. When frames from Host to Target1 are received by Cisco MDS 9148S-2 fc1/2, they are rewritten to the values in
VSAN 3 where the target resides. In the reverse direction, when frames from Target1 to the Host are received by Cisco MDS 9148S-1 fc1/2, they are rewritten to the values in VSAN 1 where the Host resides. Thus, for each VSAN transition on an ISL (that typically occurs across a transit VSAN) there will be TCAM programming for each device in the IVR zone set.
Consequently, most of the best practices followed for the F and TF port channels should be followed to ensure that TCAM is utilized as efficiently as possible for the following purposes:
Note Unlike F and TF port-channels, the ACLTCAM programming on ISLs will be the same quantity regardless if the ISLs are part of a port-channel or not. If there are "n" ISLs between two MDS switches, then it doesn't matter if they are in one port-channel, two port-channels or just individual links. The ACLTCAM programming will be the same.
• Distribute port-channel member interfaces into different forwarding engines, especially on fabric switches.
• Distribute member interfaces into different linecards on director-class switches.
• Distribute member interfaces into forwarding engines with lower TCAM zoning region usage.
• Use single-initiator zones, single-target zones, or Smart Zoning.
144
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Configuring and Managing Zones
Enhancing Zone Server Performance
Enhancing Zone Server Performance
Zone Server-Fibre Channel Name Server Shared Database
This options provides a shared database for the Zone Server and the Fibre Channel Name Sever (FCNS) to interact with one another. Sharing a database reduces the dependency of the FCNS on the zone server to manage soft zoning.
Note By default, the Zone Server- FCNS Shared Database option is enabled.
Enabling the Zone Server-FCNS Shared Database
To enable the Zone Server-FCNS shared database, perform the following steps:
Step 1
Step 2
Enter the configuration mode: switch # configure terminal
Enable database sharing for an active zone set in VSAN 1: switch(config)# zoneset capability active mode shared-db vsan 1
Example
Enabling Zone Server-FCNS Shared Database
This example shows how to enable database sharing for the active zoneset in VSAN 1 only: switch(config)# zoneset capability active mode shared-db vsan 1
SDB Activation success
Disabling Zone Server-FCNS shared database
To disable an active zone set in VSAN 1, perform the following step:
Step 1
Step 2
Enter global configuration mode: switch# configure terminal
Disable an active zone set in VSAN 1:
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
145
Configuring and Managing Zones
Zone Server SNMP Optimization switch(config)# no zoneset capability active mode shared-db vsan 1
Example
Disabling Zone Server-FCNS Shared Database
This example shows how to disable database sharing for the active zone set in VSAN 1: switch(config)# no zoneset capability active mode shared-db vsan 1
SDB Deactivation success
Zone Server SNMP Optimization
This option enables zone server-scaling enhancements for Simple Network Management Protocol (SNMP) operations, such that the zone server is not utilized for every zone query issued by the SNMP.
Note By default, the Zone Server-SNMP Optimization option is enabled..
Enabling Zone Server SNMP Optimization
To enable zone server-scaling enhancements for SNMP operations, perform the following procedure:
Step 1
Step 2
Step 3
Enter the configuration mode: switch # configure terminal
Enable zone server-SNMP optimization: switch(config)# zone capability shared-db app snmp
Display the status of the configuration: switch(config)# show running | i shared-db
Example
Enabling Zone Server- SNMP Optimizations
This example shows how to enable zone server-SNMP optimization: switch(config)# zone capability shared-db app snmp
146
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Configuring and Managing Zones
Disabling Zone Server SNMP Optimization
Disabling Zone Server SNMP Optimization
To disable zone server-SNMP optimizations, perform the following procedure:
Step 1
Step 2
Di the configuration mode: switch # configure terminal
Disable the zone server-SNMP optimizations: switch(config)# no zone capability shared-db app snmp
Example
Disabling Zone Server- SNMP Optimizations
This example shows how to disable zone server-SNMP optimization: switch(config)# no zone capability shared-db app snmp
Zone Server Delta Distribution
This feature helps distribute the difference in the zone changes between the existing zone database and the updated zone database across all the switches in a fabric. This distribution of delta changes helps avoid large payload distribution across switches whenever a zone database in modified.
Note • By default, the Zone Server Delta Distribution feature is disabled and functions in enhanced mode only.
• All the switches in a fabric should have the Zone Server Delta Distribution feature enabled. If a switch is added to the fabric with Zone Server Delta Distribution feature disabled, it will disable the Zone Server
Delta Distribution feature on all the switches in the fabric.
• The Zone Server Delta Distribution feature is supported only on Cisco MDS switches, beginning from
Cisco MDS NX-OS Release 7.3(0)D1(1).
• The Zone Server Delta Distribution feature is not available on Interactive Voice Response (IVR)-enabled
VSANs.
Enabling Zone Server Delta Distribution
To enable the distribution of data changes in a zone server, perform the following procedure:
Step 1 Enter the configuration mode:
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
147
Configuring and Managing Zones
Disabling Zone Server Delta Distribution
Step 2
Step 3 switch # configure terminal
Enable the distribution of data changes in a zone in enhanced mode: switch(config)# zone capability mode enhanced distribution diffs-only
Display the status of delta distribution (changes in data) in a fabric: switch(config)# show running | include diffs-only
Example
Enabling Zone Server Delta Distribution
This example shows how to enable distribution of changes in data in a Zone Server: switch(config)# zone capability mode enhanced distribution diffs-only
Disabling Zone Server Delta Distribution
To disable the distribution of data changes in a zone server, perform the following procedure:
Step 1
Step 2
Enter the configuration mode: switch # configure terminal
Disable the distribution of data changes in a zone: switch(config)# no zone capability mode enhanced distribution diffs-only
Example
Disabling Zone Server Delta Distribution
This example shows how to disable distribution of changes in data in a Zone Server: switch(config)# no zone capability mode enhanced distribution diffs-only
Default Settings
Table lists the default settings for basic zone parameters.
148
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Configuring and Managing Zones
Table 13: Default Basic Zone Parameters
Parameter
Enhanced zoning
Smart zoning
Default
Default zone policy
Full zone set distribute
Denied to all members.
The full zone set is not distributed.
Zone-based traffic priority Low.
Broadcast frames Unsupported.
Disabled.
Disabled.
Default Settings
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
149
Default Settings
Configuring and Managing Zones
150
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
C H A P T E R
6
Distributing Device Alias Services
All the switches in the Cisco MDS 9000 Series support Distributed Device Alias Services (device alias) on a fabric-wide basis. Device alias distribution allows you to move host bus adapters (HBAs) between VSANs without manually re-entering alias names.
This chapter includes the following sections:
•
Understanding Device Aliases, on page 151
•
Device Alias Modes, on page 151
•
Device Alias Databases, on page 158
•
About Legacy Zone Alias Configuration Conversion, on page 164
•
Database Merge Guidelines, on page 165
•
Device Alias Configuration Verification, on page 165
•
Default Settings , on page 168
•
Resolving Device Alias Merge Failures, on page 168
Understanding Device Aliases
While the port WWN (pWWN) of a device has to be specified to configure different features (zoning, QoS, and port security) in a Cisco MDS 9000 Family switch, you must assign the correct device name each time you configure these features. An incorrect device name may cause unexpected results. You can avoid this if you define a user-friendly name for a pWWN and use this name in all of the configuration commands, as required. These user-friendly names are referred to as device aliases in this chapter.
Device Alias Modes
Device-Alias Basic Mode and Enhanced Mode
The device alias feature supports two modes, basic mode and enhanced mode.
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
151
Distributing Device Alias Services
Guidelines and Limitations
Note • For applications such as NX-OS processes (zone, dpvm, ivr, and so on), the device-alias configurations get mapped to their PWWNs when device-alias is in basic mode. Whereas if device-alias is in enhanced mode, the device-alias configuration of the applications do not get mapped to their PWWNs immediately but will remain as configured in application which is referred as native form or format.
• From Cisco MDS NX-OS Release 8.5(1), the default device alias mode is enhanced mode.
When using device alias in basic mode, NX-OS processes such as zone, DPVM, IVR, and so on, immediately expand the device alias name into its associated pWWN in the configuration. For example, when a device alias member is added to a zone, it will be added as a pWWN member and not as a device alias member.
Therefore, when you change the pWWN for the device alias entry any configuration (besides device alias) does not get automatically updated. You should manually edit the zones containing that device alias by removing the old entry and reconfiguring the zones and any other configuration where the PWWN is used by removing the old PWWN entry and adding it back with the same device alias name that now has the updated
PWWN. After that is done, the configuration should be made active in whatever method is appropriate for the change. For example, if a zone was modified then the zoneset should be reactivated and committed, if necessary.
When using device alias in enhanced mode, NX-OS processes such as zone, DPVM, IVR, and so on, store the device alias names natively in the configuration as specified instead of expanding to pWWNs. The applications track the device alias database changes and take the necessary actions to enforce any changes made (for example like renaming a device alias).
In this mode, since the configuration is accepted in the native form, when the pWWN for the device alias is changed, the zones or other configuration containing that device alias are automatically updated.
Guidelines and Limitations
A native device alias configuration is not accepted in the interop mode VSAN. IVR zone set activation fails in the interop mode VSANs if the corresponding twilight zones being injected are native device alias members.
Device-Alias Mode Default
From Cisco MDS NX-OS Release 8.5(1), the default device alias mode is enhanced mode. Prior to Cisco
MDS NX-OS Release 8.5(1), the default device alias mode was basic mode. After an upgrade from an earlier release to Cisco MDS NX-OS Release 8.5(1) or later releases, the device alias mode is set to enhanced mode only when there are no device alias entries configured and the device alias mode is basic. If device alias entries are present or the device alias mode is already in enhanced mode, then the device alias mode is not changed.
When a switch initially boots up Cisco MDS NX-OS Release 8.5(1) or later releases, the default device alias mode is set to enhanced mode. If the switch is being downgraded from Cisco MDS NX-OS Release 8.5(1) or later releases to a Cisco MDS NX-OS Release 8.4(2b) or earlier releases and there are no device alias entries configured and the device alias mode is not set, the default alias mode reverts to basic mode. If device alias entries are present or the device alias mode is set, the device alias mode is not changed.
Downgrading from Cisco MDS NX-OS Release 8.5(1) to Release 8.4(2c) is a disruptive operation. Therefore, the device alias configuration is not retained on the switch and the default device alias mode is changed to basic mode, which is the default device alias mode in the Release 8.4(2c), after downgrading.
When the default has been set to enhanced mode the following syslog message will be displayed:
%DEVICE-ALIAS-2-DDAS_DEFAULT_MODE: Device alias mode has been set to enhanced mode
152
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Distributing Device Alias Services
Changing Mode Settings
Note If a new switch running Cisco MDS NX-OS Release 8.5(1) or later releases is being introduced into an existing fabric running in device alias basic mode, then the device alias mode must be configured to basic mode in the new switch or the device alias mode can be set to enhanced mode for the switches in the existing fabric.
Changing Mode Settings
When a device alias mode is changed from basic mode to enhanced mode, the corresponding applications are informed about the change. The applications then start accepting the device alias-based configuration in the native format.
Note Because the device alias was previously running in the basic mode, the applications do not have any prior native device alias configuration.
The applications check for an existing device alias configuration in the native format. If the device alias is in the native format, the applications reject the request, and the device alias mode cannot be changed to basic.
All the native device alias configurations (both on local and remote switches) must be explicitly removed, or all the device alias members must be replaced with the corresponding pWWNs before changing the mode back to basic.
Device Alias Mode Distribution
If device alias distribution is turned on, it is distributed to the other switches in the network whenever there is a change in the mode.
Device Alias Diffs-Only Distribution
From the Cisco MDS NX-OS Release 7.3(0)D1(1), the Device Alias Diffs-Only Distribution feature is supported on the Cisco MDS switches.
When this feature is enabled on all the switches in a fabric, only the session commands are sent across the fabric instead of the entire database, which helps ensure better scalability.
DDAS supports 20,000 entries when all the switches in a fabric have the Device Alias Diffs-Only Distribution feature enabled. This feature is enabled by default.
Note Ensure that all the switches in a fabric are running a minimum of Cisco MDS NX-OS Release 7.3(0)D1(1) with the Device Alias Diffs-Only feature enabled.
Configuring Device Alias Diffs-Only Distribution
To configure the Device Alias Diff-Only Distribution feature, follow these steps:
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
153
Distributing Device Alias Services
Configuring Device Alias Diffs-Only Distribution
Step 1
Step 2
Step 3 switch# configure terminal
Enters configuration mode.
switch(config)# device-alias distribute diffs-only
Enable the distribution of diffs only on the switch.
This example shows how to enable and display the Device Alias Diffs-Only Distribution feature status on a switch:
Example: switch(config)# device-alias distribute diffs-only switch(config)# show device-alias status
Fabric Distribution: Enabled
Diffs-only Distribution: Enabled
Database:- Device Aliases 1 Mode: Basic
Checksum: 0x43a9fe35852e91354543d712c3ec9d3
Displaying Device Alias Diffs-Only Distribution Status
This example shows the device alias status during an active session when the Device Alias Diffs-Only Distribution feature is enabled on a switch and in a fabric:
Example: switch(config-device-alias-db)# show device-alias status
Fabric Distribution: Enabled
Diffs-only Distribution: Disabled
Database:- Device Aliases 0 Mode: Basic
Checksum: 0xf6bd6b3389b87233d462029172c8612
Locked By:- User "CLI/SNMPv3:admin" SWWN 20:00:54:7f:ee:1c:2d:40
Pending Database:- Device Aliases 1 Mode: Basic
Diffs-only Distribution capability in the fabric: Enabled
Diffs-only distribution in Session: Enabled
This example shows the device alias status during an active session when the Device Alias Diff-Only Distribution feature is disabled on a switch and in a fabric:
Example: switch(config-device-alias-db)# show device-alias status
Fabric Distribution: Enabled
Diffs-only Distribution: Disabled
Database:- Device Aliases 0 Mode: Basic
Checksum: 0xf6bd6b3389b87233d462029172c8612
Locked By:- User "CLI/SNMPv3:admin" SWWN 20:00:54:7f:ee:1c:2d:40
Pending Database:- Device Aliases 1 Mode: Basic
Diffs-only Distribution capability in the fabric: Disabled
SWWN which doesnot support Diffs-only Distribution:
20:00:54:7f:ee:1c:2d:40
20:00:54:7f:e1:1c:2c:40
Diffs-only distribution in Session: Disabled
Note The status of Diffs-only distribution in session does not change during a session.
switch(config)# no device-alias distribute diffs-only
Disables Device Alias Diffs-Only Distribution
This example shows how to disable and display the Device Alias Diffs-Only Distribution feature status on a switch:
154
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Distributing Device Alias Services
Merging Device Alias with the Diffs-Only Distribution Feature Enabled
Example: switch(config)# no device-alias distribute diffs-only switch(config)# show device-alias status
Fabric Distribution: Enabled
Diffs-only Distribution: Disabled
Database:- Device Aliases 1 Mode: Basic
Checksum: 0x43a9fe35852e91354543d712c3ec9d3
Merging Device Alias with the Diffs-Only Distribution Feature Enabled
Device alias merge failure occurs in the following scenarios:
• When a switch configured with more than 12,000 entries and enabled with the Device Alias Diffs-Only
Distribution feature is added to a fabric, that does not support the feature.
• When a switch with disabled Device Alias Diff-Only Distribution feature is added to a fabric, that is configured with more than 12,000 entries and enabled with the Device Alias Diffs-Only feature.
Displaying Merge Failure
This example displays device alias merge failure when one of the fabrics does not support more than
12,000 entries: switch(config)# show cfs merge status name device-alias
Physical-fc Merge Status: Failed [ Wed Jan 20 10:00:34 2016 ]
Failure Reason: One of the merging fabrics cannot support more than 12Kdevice-al iases
Note The Diffs-Only Distribution feature should be enabled on all the switches in a fabric for the device alias entries (more than 12,000) to be supported. If the Diffs-Only Distribution feature is not enabled on all the switches in a fabric, we recommend that you do not configure more than 12,000 entries.
Merging Device Alias in Different Modes
If two fabrics are running different device alias modes, the device alias merge fails. There is no automatic conversion of one mode to the other during the merge process. You will need to resolve the issue.
At the application level, a merger takes place between the applications and the fabric. For example, zone merge occurs when the E port is up, and the IVR,PSM/DPVM merge occurs due to CFS. This merge is completely independent of the device alias merge.
If an application running on an enhanced fabric has a native device alias configuration, the application must fail the merge even if the other fabric is can support the native device alias-based configuration, but is running in the basic mode. You will need to resolve the issue. After the device alias merge issue is resolved, each application must be fixed accordingly.
The following issue occurs when there is a device alias database mismatch in the switches that are a part of the same fabric:
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
155
Distributing Device Alias Services
Resolving Merge Failure and Device Alias Mode Mismatch
The device alias associated to a pWWN is present in the port security/DPVM database even if the respective device alias member is not present in the switch. The device alias associated to a pWWN is missing in the port security/DPVM database even if the respective device alias member is present in the switch.
Resolving Merge Failure and Device Alias Mode Mismatch
If two fabrics are running in different modes and the device alias merge fails between the fabrics, the conflict can be resolved by selecting one mode or the other. Otherwise, the enhanced mode cannot be turned on. If you choose the basic mode, the applications running on the enhanced fabric have to comply with the device alias merge.
The device alias merge fails because of mode mismatch, but the application merge succeeds if it does not have any native device alias configurations.
Note The applications should not accept any native device alias configuration over SNMP if the device alias is running in the basic mode on that particular switch.
Note Confcheck will be added when the enhanced mode is turned on and removed when it is turned off. Applications should add confcheck if they have a device alias configuration in the native format, and remove it after the configuration is removed.
Device Alias Features
Device aliases have the following features:
• Device alias information is independent of your VSAN configuration.
• Device alias configuration and distribution is independent of the zone server and the zone server database.
• You can import legacy zone alias configurations without losing data.
• The device alias application uses the Cisco Fabric Services (CFS) infrastructure to enable efficient database management and distribution. Device aliases use the coordinated distribution mode and the fabric-wide distribution scope (refer to the Cisco MDS 9000 Family NX-OS System Management
Configuration Guide ).
• When you configure zones, IVR zones, or QoS features using device aliases, and if you display these configurations, you will automatically see that the device aliases are displayed along with their respective pWWNs.
Device Alias Requirements
Device aliases have the following requirements:
• You can only assign device aliases to pWWNs.
• The mapping between the pWWN and the device alias to which it is mapped must have a one-to-one relationship. A pWWN can be mapped to only one device alias and vice versa.
156
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Distributing Device Alias Services
Zone Aliases Versus Device Aliases
• Prior to Cisco MDS NX-OS Release 9.2(2), a device-alias name was restricted to 64 alphanumeric characters. From Cisco MDS NX-OS Release 9.2(2), the device-alias name is restricted to 63 alphanumeric characters and may include one or more of the following characters:
• a to z and A to Z
• 1 to 9
• - (hyphen) and _ (underscore)
• $ (dollar sign) and ^ (up caret)
Note For releases prior to Cisco MDS NX-OS Release 9.2(2), if the device-alias name was 64 characters in length, the DPVM and other application databases do not update properly. Restrict the number of characters in the device-alias name to
63.
Zone Aliases Versus Device Aliases
Table 14: Comparison Between Zone Aliases and Device Aliases , on page 157
compares the configuration differences between zone-based alias configuration and device alias configuration.
Table 14: Comparison Between Zone Aliases and Device Aliases
Zone-Based Aliases
Aliases are limited to the specified VSAN.
Device Aliases
You can define device aliases without specifying the VSAN number. You can also use the same definition in one or more
VSANs without any restrictions.
Device aliases can be used with any feature that uses the pWWN.
Zone aliases are part of the zoning configuration. The alias mapping cannot be used to configure other features.
You can use any zone member type to specify the end devices.
Only pWWNs are supported along with new device aliases such as IP addresses.
Configuration is contained within the Zone Server database and is not available to other features.
Device aliases are not restricted to zoning. Device alias configuration is available to the FCNS, zone, fcping, traceroute, and IVR applications.
FC aliases are not displayed with the associated WWNs in the show command outputs like show zoneset active, show flogi database, and show fcns database.
Device aliases are displayed with the associated WWNs in the show command outputs like show zoneset active, show flogi database, and show fcns database.
FC aliases are not distributed as part of active zoneset and are only distributed as part of full zone database as per the FC standards.
Device Aliases are distributed through CFS.
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
157
Distributing Device Alias Services
Device Alias Databases
Device Alias Databases
The device alias feature uses two databases to accept and implement device alias configurations.
• Effective database—The database currently used by the fabric.
• Pending database—Your subsequent device alias configuration changes are stored in the pending database.
If you modify the device alias configuration, you need to commit or discard the changes as the fabric remains locked during this period.
This section includes the following sections:
Creating Device Aliases
To a create a device alias in the pending database, follow these steps:
Step 1
Step 2
Step 3
Step 4
Step 5 switch# config t switch(config)#
Enters configuration mode.
switch(config)# device-alias database switch(config-device-alias-db)#
Enters the pending database configuration submode.
switch(config-device-alias-db)# device-alias name Device1 pwwn 21:01:00:e0:8b:2e:80:93
Specifies a device name (Device1) for the device that is identified by its pWWN. Starts writing to the pending database and simultaneously locks the fabric as this is the first-issued device alias configuration command.
switch(config-device-alias-db)# no device-alias name Device1
Removes the device name (Device1) for the device that is identified by its pWWN.
switch(config-device-alias-db)# device-alias rename Device1 Device2
Renames an existing device alias (Device1) with a new name (Device2).
To display the device alias configuration, use the show device-alias name command.
switch# show device-alias name x device-alias name x pwwn 21:01:00:e0:8b:2e:80:93
About Device Alias Distribution
By default, device alias distribution is enabled. The device alias feature uses the coordinated distribution mechanism to distribute the modifications to all switches in a fabric.
If you have not committed the changes and you disable distribution, then a commit task will fail.
158
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Distributing Device Alias Services
About Creating a Device Alias
Displays a Failed Status switch# show device-alias status
Fabric Distribution: Disabled
Database:- Device Aliases 25
Status of the last CFS operation issued from this switch:
==========================================================
Operation: Commit
Status: Failed (Reason: Operation is not permitted as the fabric distribution is currently disabled.)
Note From the Cisco MDS NX-OS Release 6.2.9 onwards, the ASCII configuration replay takes longer time for DDAS (Distributing Device Alias Services) without the write erase command.
About Creating a Device Alias
When you perform the first device alias task (regardless of which device alias task), the fabric is automatically locked for the device alias feature. Once you lock the fabric, the following situations apply:
• No other user can make any configuration changes to this feature.
• A copy of the effective database is obtained and used as the pending database. Modifications from this point on are made to the pending database. The pending database remains in effect until you commit the modifications to the pending database or discard ( abort ) the changes to the pending database.
About Device Alias Configuration Best Practices
As a part of the device-alias configuration best practices, the following guidelines need to be adopted within a device-alias session:
If a device-alias name is reused while configuring a rename command, then the command fails and gets moved to the rejected list.
Displays the rejected device-alias command switch(config-device-alias-db)# device-alias name dev10 pwwn 10:10:10:10:10:10:10:10 switch(config-device-alias-db)# device-alias rename dev10 new-dev10
Command rejected. Device-alias reused in current session :dev10
Please use 'show device-alias session rejected' to display the rejected set of commands and for the device-alias best-practices recommendation.
switch(config-device-alias-db)#
If a PWWN is reused while configuring an add or delete command, then the command fails and gets moved to the rejected list.
Displays the rejected device-alias command switch(config-device-alias-db)# device-alias name dev11 pwwn 11:11:11:11:11:11:11:11 switch(config-device-alias-db)# no device-alias name dev11
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
159
Distributing Device Alias Services
Committing Changes
Command rejected. Pwwn reused in current session: 11:11:11:11:11:11:11:11 is mapped to device-alias dev11
Please use 'show device-alias session rejected' to display the rejected set of commands and for the device-alias best-practices recommendation.
switch(config-device-alias-db)#
If a device-alias name is reused in an add command which was earlier being renamed in a rename command, the command fails and gets moved to the rejected list.
switch(config-device-alias-db)# device-alias rename da3 new-da3 switch(config-device-alias-db)# device-alias name da3 pwwn 2:2:2:2:3:3:3:3
Command rejected. Device-alias name reused in current session: da3
Please use 'show device-alias session rejected' to display the rejected set of commands and for the device-alias best-practices recommendation.
switch(config-device-alias-db)#
Displays the rejected device-alias command
The rejected set of commands can be displayed using the show device-alias session rejected command.
switch(config-device-alias-db)# show device-alias session rejected
To avoid command rejections, within a device alias session
Do not reuse: a) a device alias name while configuring a rename command b) a PWWN while configuring an add or delete command c) a device alias name already renamed while configuring add command
Rejected commands must be committed in a separate device alias session which may cause traffic interruption for those devices. Plan accordingly.
Refer to this command in the NX-OS Command Reference Guide for more information about device alias configuration best practices
Rejected Command List
--------------------device-alias rename dev10 new-dev10 no device-alias name dev11 device-alias name da3 pwwn 02:02:02:02:03:03:03:03 switch(config-device-alias-db)# #
Committing Changes
If you commit the changes made to the pending database, the following events occur:
1.
The pending database contents overwrites the effective database contents.
2.
The pending database is emptied of its contents.
3.
The fabric lock is released for this feature.
To commit the changes, follow these steps:
Step 1
Step 2 switch# config terminal switch(config)#
Enters configuration mode.
switch(config)# device-alias commit
Commits the changes made to the currently active session.
160
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Distributing Device Alias Services
Enabling the Device Alias Pending Diff Display
Whenever a switch in the fabric gets locked and goes for a blank commit, the following warning is displayed:
WARNING: Device-alias DB is empty in this switch.
Initiating a commit from this switch will clear [wipe out] Device-alias DB across all the switches in the fabric, losing Device-alias full DB config permanently.
Do you want to continue? (y/n) [n]
Note Once the "device-alias commit" is done the running configuration has been modified on all switches participating in device-alias distribution. You can then use the "copy running-config startup-config fabric" command to save the running-config to the startup-config on all the switches in the fabric.
Enabling the Device Alias Pending Diff Display
To enable the display of the pending-diff and the subsequent confirmation on issuing a device-alias commit, follow these steps:
Step 1
Step 2
Step 3 switch# config t switch(config)#
Enters configuration mode.
switch(config)# device-alias confirm-commit
Enables the confirm commit option for device- alias.
switch(config)# device-alias commit
The following device-alias changes are about to be committed
+ device-alias name Device1 pwwn 21:01:00:e0:8b:2e:80:93
Do you want to continue? (y/n) [n] y
If the device-alias confirm-commit command is enabled, on committing the pending database, the pending-diff is displayed on the console and user is prompted for Yes or No. If the device -alias confirm-commit command is disabled, the pending-diff is not displayed and the user is not prompted for Yes or No.
Discarding Changes
If you discard the changes made to the pending database, the following events occur:
1.
The effective database contents remain unaffected.
2.
The pending database is emptied of its contents.
3.
The fabric lock is released for this feature.
To discard the device alias session, perform this task:
Step 1 switch# config terminal switch(config)#
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
161
Distributing Device Alias Services
Fabric Lock Override
Step 2
Enters configuration mode.
switch(config)# device-alias abort
Discards the currently active session.
To display the status of the discard operation, use the show device alias status command.
switch# show device-alias status
Fabric Distribution: Enabled
Database:- Device Aliases 24
Status of the last CFS operation issued from this switch:
==========================================================
Operation: Abort
Status: Success
Fabric Lock Override
If you have performed a device alias task and have forgotten to release the lock by either committing or discarding the changes, an administrator can release the lock from any switch in the fabric. If the administrator performs this task, your changes to the pending database are discarded and the fabric lock is released.
Tip The changes are only available in the volatile directory and are subject to being discarded if the switch is restarted.
To clear device-alias session, use the clear device-alias session command in CONFIGURATION mode.
switch(config)# clear device-alias session
To verify the status of the clear operation, use the show device-alias session status command.
switch(config)# show device-alias session status
Last Action Time Stamp : None
Last Action
Last Action Result
: None
: None
Last Action Failure Reason : none
Clearing Database Content
To clear all the database content, use the clear device-alias database command in
CONFIGURATION mode.
switch(config)# clear device-alias database
To verify the status of the clear device-alias database command, use the s how device-alias database command.
switch(config)# show device-alias database
162
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Distributing Device Alias Services
Clearing Statistics
Clearing Statistics
To clear all the statistics, use the clear device-alias statistics command in CONFIGURATION mode.
switch# clear device-alias statistics
Disabling and Enabling Device Alias Distribution
To disable or enable the device alias distribution, follow these steps:
Step 1
Step 2
Step 3 switch# config t switch(config)#
Enters configuration mode.
switch(config)# no device-alias distribute
Disables the distribution.
switch(config)# device-alias distribute
Enables the distribution (default).
To display the status of device alias distribution, use the show device-alias status command (see the following examples).
Displays Device Alias Status When Distribution Is Enabled
Displays Device Alias Status When Distribution Is Disabled switch# show device-alias status
Fabric Distribution: Enabled <-------------------------------Distribution is enabled
Database:-Device Aliases 24
Locked By:-User “Test” SWWN 20:00:00:0c:cf:f4:02:83<-Lock holder’s user name and switch ID
Pending Database:- Device Aliases 24
Status of the last CFS operation issued from this switch:
==========================================================
Operation: Enable Fabric Distribution
Status: Success switch# show device-alias status
Fabric Distribution: Disabled
Database:- Device Aliases 24
Status of the last CFS operation issued from this switch:
==========================================================
Operation: Disable Fabric Distribution
Status: Success
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
163
Distributing Device Alias Services
About Legacy Zone Alias Configuration Conversion
About Legacy Zone Alias Configuration Conversion
You can import legacy zone alias configurations to use this feature without losing data, if they satisfy the following restrictions:
• Each zone alias has only one member.
• The member type is pWWN.
• The name and definition of the zone alias should not be the same as any existing device alias name.
If any name conflict exists, the zone aliases are not imported.
Tip Ensure to copy any required zone aliases to the device alias database as required by your configuration.
When an import operation is complete, the modified alias database is distributed to all other switches in the physical fabric when you perform the commit operation. At this time if you do not want to distribute the configuration to other switches in the fabric, you can perform the abort operation and the merge changes are completely discarded.
This section includes the following topics:
Importing a Zone Alias
Note Device alias does not allow importing and manually adding of device alias entries to the database in the same session.
To import the zone alias for a specific VSAN, follow these steps:
SUMMARY STEPS
1.
switch# config t
2.
switch(config)# device-alias import fcalias vsan 3
DETAILED STEPS
Step 1
Command or Action switch# config t
Example:
Step 2 switch# config t switch(config)# switch(config)# device-alias import fcalias vsan 3
Purpose
Enters configuration mode.
Imports the fcalias information for the specified VSAN.
To display device alias information in zone sets, use the show zoneset command (see the following examples ).
164
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Distributing Device Alias Services
Device Alias Statistics Cleanup
Displays the Device Aliases in the Zone Set Information switch# show zoneset zoneset name s1 vsan 1 zone name z1 vsan 1 pwwn 21:01:00:e0:8b:2e:80:93 [x] <--------------Device alias displayed for each pWWN.
pwwn 21:00:00:20:37:39:ab:5f [y] zone name z2 vsan 1 pwwn 21:00:00:e0:8b:0b:66:56 [SampleName] pwwn 21:00:00:20:37:39:ac:0d [z]
Example: Displays the Device Aliases in the Active Zone Set switch# show zoneset active zoneset name s1 vsan 1 zone name z1 vsan 1
* fcid 0x670100 [pwwn 21:01:00:e0:8b:2e:80:93] [x] pwwn 21:00:00:20:37:39:ab:5f [y] zone name z2 vsan 1
* fcid 0x670200 [pwwn 21:00:00:e0:8b:0b:66:56] [SampleName] pwwn 21:00:00:20:37:39:ac:0d [z]
Device Alias Statistics Cleanup
Use the clear device-name statistics command to clear device alias statistics (for debugging purposes): switch# clear device-alias statistics
Database Merge Guidelines
For information about CFS merge support, refer to the Cisco MDS 9000 Series NX-OS System Management
Configuration Guide for detailed concepts.
When merging two device alias databases, follow these guidelines:
• Verify that two device aliases with different names are not mapped to the same pWWN.
• Verify that two different pWWNs are not mapped to the same device aliases.
• Ensure the device -alias mode is similar for the both the fabrics being merged.
Device Alias Configuration Verification
You can view device alias information by using the show device-alias command. See the following examples.
Displays All Configured Device Aliases from the Effective Database switch# show
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
165
Distributing Device Alias Services
Device Alias Configuration Verification device-alias database device-alias name SampleName pwwn 21:00:00:e0:8b:0b:66:56 device-alias name x pwwn 21:01:00:e0:8b:2e:80:93
Total number of entries = 2
Displays the Pending Database with No Modifications switch# show device-alias database pending
There are no pending changes
Displays the Pending Database with Modifications switch# show device-alias database pending device-alias name x pwwn 21:01:00:e0:8b:2e:80:93 device-alias name SampleName pwwn 21:00:00:e0:8b:0b:66:56 device-alias name y pwwn 21:00:00:20:37:39:ab:5f device-alias name z pwwn 21:00:00:20:37:39:ac:0d
Total number of entries = 4
Displays the Specified Device Name in the Pending Database switch# show device-alias name x pending device-alias name x pwwn 21:01:00:e0:8b:2e:80:93
Displays the Specified pWWN in the Pending Database switch# show device-alias pwwn 21:01:00:e0:8b:2e:80:93 pending device-alias name x pwwn 21:01:00:e0:8b:2e:80:93
Displays the Difference Between the Pending and Effective Databases switch# show device-alias database pending-diff
- device-alias name Doc pwwn 21:01:02:03:00:01:01:01
+ device-alias name SampleName pwwn 21:00:00:e0:8b:0b:66:56
Displays the Specified pWWN switch# show device-alias pwwn 21:01:01:01:01:11:01:01 device-alias name Doc pwwn 21:01:01:01:01:11:01:01
Displays the Device Alias in the FLOGI Database switch# show flogi database
---------------------------------------------------------------------------
INTERFACE VSAN FCID PORT NAME NODE NAME
--------------------------------------------------------------------------fc2/9 1 0x670100 21:01:00:e0:8b:2e:80:93 20:01:00:e0:8b:2e:80:93
[ x
166
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Distributing Device Alias Services
Device Alias Configuration Verification
] <---------------------------------------------Device alias name fc2/12 1 0x670200 21:00:00:e0:8b:0b:66:56
[ SampleName
20:00:00:e0:8b:0b:66:56
] <---------------------------------Device alias name
Total number of flogi = 2
Displays the Device Alias in the FCNS Database switch# show fcns database
VSAN 1:
--------------------------------------------------------------------------
FCID TYPE PWWN (VENDOR) FC4-TYPE:FEATURE
--------------------------------------------------------------------------
0x670100 N 21:01:00:e0:8b:2e:80:93 (Qlogic)
[ x scsi-fcp:init
]
0x670200 N 21:00:00:e0:8b:0b:66:56 (Qlogic)
[ SampleName
]
Total number of entries = 2 scsi-fcp:init
Displays the fcping Statistics for the Specified Device Alias switch# fcping device-alias x vsan 1
28 bytes from 21:01:00:e0:8b:2e:80:93 time = 358 usec
28 bytes from 21:01:00:e0:8b:2e:80:93 time = 226 usec
28 bytes from 21:01:00:e0:8b:2e:80:93 time = 372 usec
Displays the fctrace Information for the Specified Device Alias switch# fctrace device-alias x vsan 1
Route present for : 21:01:00:e0:8b:2e:80:93
20:00:00:05:30:00:4a:e2(0xfffc67)
Where available, device aliases are displayed regardless of a member being configured using a device-alias command or a zone-specific member pwwn command.
Displays Statistics for the Device Alias Application switch# show device-alias statistics
Device Alias Statistics
===========================================
Lock requests sent: 2
Database update requests sent: 1
Unlock requests sent: 1
Lock requests received: 1
Database update requests received: 1
Unlock requests received: 1
Lock rejects sent: 0
Database update rejects sent: 0
Unlock rejects sent: 0
Lock rejects received: 0
Database update rejects received: 0
Unlock rejects received: 0
Merge requests received: 0
Merge request rejects sent: 0
Merge responses received: 2
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
167
Distributing Device Alias Services
Default Settings
Merge response rejects sent: 0
Activation requests received: 0
Activation request rejects sent: 0
Activation requests sent: 2
Activation request rejects received: 0
Default Settings
Table 15: Default Device Alias Parameters , on page 168
lists the default settings for device alias parameters.
Table 15: Default Device Alias Parameters
Parameters Default
Database in use Effective database.
Database to accept changes Pending database.
Device alias fabric lock state Locked with the first device alias task.
Resolving Device Alias Merge Failures
The most common device-alias merge failure issues occur when merging databases. When a device-alias merge fails, we recommend that you review the syslog messages on the switch in which the merge was initiated in order to identify the issues. The application server in each fabric that is responsible for the merge is indicated by the term Merge Master in the messages.
In this example, the syslog messages indicate that the merge failed as a result of a database mismatch:
2007 Apr 9 15:52:42 switch-1 %CFS-3-MERGE_FAILED: Merge failed for app device-alias, local switch wwn 20:00:00:0d:ec:2f:c1:40,ip 172.20.150.38, remote switch wwn
20:00:00:0d:ec:04:99:40, ip 172.20.150.30
2007 Apr 9 15:52:42 switch-1 %DEVICE-ALIAS-3-MERGE_FAILED: Databases could not be merged due to mismatch.
Note Use the device-alias distribute command to initiate a merge or remerge of device-alias databases. Use the device-alias commit command to push a switch's device-alias database to all the other switches in a fabric.
If the switches whose device-alias databases are not merged (more than one merge master is shown in the output of the show cfs merge status name device-alias command), then the device-alias commit command causes the device-alias databases that are not merged to be overwritten.
Device Alias Best Practices
This section lists the best practices that you should follow when creating and using device aliases:
168
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Distributing Device Alias Services
Device Alias Best Practices
• Device aliases should be used to simplify the management of world wide names (WWNs) whenever possible. It is easier to identify devices with aliases rather than with WWNs. Hence, you should assign aliases to WWNs to easily identify the WWNs.
• Device-alias names are case-sensitive.
• Operate device aliases in Enhanced mode whenever possible. In Enhanced mode, applications accept a device-alias name in its native format, rather than expanding the alias to a port world wide name (pWWN).
Because applications such as zone server, Inter-VSAN Routing (IVR), Port Security Manager (PSM), and Dynamic Port VSAN Membership automatically track and enforce device-alias membership changes, you have a single point of change.
Note Interop mode VSANs do not accept Enhanced mode configurations.
• Preplan device-alias configurations and implement a consistent naming convention.
• Keep documented backups of all device-alias configurations.
• Plan for what the final device-alias database should be after the merge, before attempting to resolve merge failures. This can prevent traffic disruptions caused by accidentally overwriting device-alias entries.
Caution Avoid performing a blank commit to resolve Cisco Fabric Services (CFS) merge failures. A blank commit overwrites the device-alias databases on all the switches with the device-alias database on the local switch.
Note A blank commit is a device-alias commit that is used when there are no changes
(including mode changes), or when it is okay to overwrite the device-alias databases on the remote switches with the local switch’s device-alias database.
Device alias mismatches might occur because of the following reasons:
• Duplicate Device-Alias Names—Same device-alias name, but different pWWNs. In such a scenario, the show device-alias merge status command displays the reason for the merge failure as Reason:
Another device-alias already present with the same name .
• Duplicate pWWNs—Different device-alias names, but same pWWN. In such a scenario, the show device-alias merge status command displays the reason for the merge failure as Reason:
Another device-alias already present with the same pwwn .
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
169
Distributing Device Alias Services
Resolving Device Alias Mismatches
Note Each time device-alias changes are committed, the running configuration should be copied to the startup configuration on all the switches that were updated. Use the copy running-config startup-config fabric command to copy the running configuration to the startup configuration for all the switches in the fabric. If you do not copy the running configuration to the startup configuration after the device-alias changes are committed, and if the switch reloads, or loses power and restarts, the startup configuration will not have the correct device-alias database and merge failure will occur.
• You will be unable to upgrade to Cisco MDS NX-OS Release 9.2(2) or later releases if you have configured the device-alias name using 64 alphanumeric characters. For more information, see the Cisco MDS 9000
NX-OS Software Upgrade and Downgrade Guide, Release 9.x
.
Resolving Device Alias Mismatches
If a switch with an existing device-alias database is being added to an existing fabric, conflicts might arise because of the following reasons:
• The same device-alias name is used, but with different pWWNs.
• The same pWWN is used, but with different device-alias names.
To resolve duplicate device-alias names, perform these steps:
Step 1 Run the show cfs merge status name device-alias command to review the CFS or device-alias merge failure syslogs to confirm that the merge failed: switch-1# show cfs merge status name device-alias
Physical-fc Merge Status: Failed
[Sun Sep 25 14:45:55 2016]
Failure Reason: Another device-alias already present with the same pwwn
Local Fabric
--------------------------------------------------------------------------------
Switch WWN IP Address
--------------------------------------------------------------------------------
20:00:54:7f:ee:1b:0e:b0 10.127.103.211
[switch-1]
[Merge Master] <<< Merge Master#1
Total number of switches = 1
Remote Fabric
--------------------------------------------------------------------------------
Switch WWN IP Address
--------------------------------------------------------------------------------
20:00:54:7f:ee:1b:0e:50 10.197.111.54
[Merge Master] <<< Merge Master#2
Total number of switches = 1
170
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Distributing Device Alias Services
Resolving Merge Failures
Step 2
Step 3
Note A properly merged device-alias application should only show a single merge master. If there is more than one merge master, as shown in the above example, it indicates that the device-alias databases are not merged.
Use the no device-alias distribute command on the switch in which the merge failure occurred in order to disable the device-alias distribution: switch-1# configure terminal switch-1(config)# no device-alias distribute
Resolve merge failure on the switch. See
Resolving Merge Failures, on page 171
section.
Resolving Merge Failures
This section provides information about how to resolve merge failures.
Resolving Duplicate Device Alias Names (Same Device Alias Name, Different pWWNs)
Note A device-alias name is considered to be duplicate when the same device-alias name is used to point to different pWWNs.
To verify if a duplicate device-alias name exists in fabrics, perform these steps:
Step 1
Step 2
Run the show device-alias merge status command to identify if the reason for the merge failure is a database mismatch: switch# show device-alias merge status
Result: Failure
Reason: Another device-alias already present with the same name
Note A properly merged device-alias application should only show a single merge master. If there is more than one merge master, as shown in the above example, it indicates that the device-alias databases are not merged.
Review the CFS or the device-alias merge failure syslog to confirm that the merge failed. Alternatively, run the show cfs merge status name device-alias command to view the status of the merge: switch# show cfs merge status name device-alias
Physical-fc Merge Status: Failed [ Mon Apr 9 15:57:58 2007 ] <===Merge status
Local Fabric
-------------------------------------------------------------------------
Switch WWN IP Address
-------------------------------------------------------------------------
20:00:00:0d:ec:2f:c1:40 172.20.150.38
switch-1
[Merge Master] <<< Merge Master#1
Total number of switches = 1
Remote Fabric
-------------------------------------------------------------------------
Switch WWN IP Address
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
171
Distributing Device Alias Services
Resolving Duplicate Device Alias Names (Same Device Alias Name, Different pWWNs)
Step 3
-------------------------------------------------------------------------
20:00:00:0d:ec:04:99:40 172.20.150.30
[Merge Master] <<< Merge Master#2 switch-2
Total number of switches = 1
Depending on the Cisco MDS NX-OS release your switch is using, run one of the following commands:
• Cisco MDS NX-OS Release 8.1(1) and later releases
Run the show device-alias merge conflicts command to display the device alias and pWWNs that are causing the merge failure.
Note Run the show device-alias merge conflicts command from a switch listed as a merge master.
In the following example, the same device-alias name, A1, is assigned to two different pWWNs—a pWWN on a local switch and a pWWN on a peer switch: switch-1# show device-alias merge conflicts
Merge Status : Failure
Peer Switch SWWN : 20:00:00:0d:ec:24:f5:00
Conflicts :
1. Conflicting Pwwns : 1
-------------------------------------------------------------------------
Local PWWN Peer PWWN Device-alias
------------------------------------------------------------------------pwwn 0:01:01:01:01:01:01:02 pwwn :01:01:01:01:01:01:03 A1
• Cisco MDS NX-OS Release 7.3 and earlier releases
Compare the device-alias databases manually to identify the duplicate device-alias names.
In the following example, the same device-alias name, A1, is assigned to two different pWWNs—a pWWN on a local switch and a pWWN on a peer switch.
From merge master#1: switch-1# show device-alias database
...output trimmed to show only mismatched device-alias device-alias name A1 pwwn 21:01:01:01:01:01:01:02 switch-2# show device-alias database
...output trimmed to show only mismatched device-alias device-alias name A1 pwwn 21:01:01:01:01:01:01:03
Step 4 Run the device-alias name name pwwn id command to change the pWWN on one of the switches to match the pWWN on the other switch.
Note Perform this step after device-alias distribution is disabled by running the no device-alias distribute command.
In the following example, the pWWN 21:01:01:01:01:01:01:02 on switch-1 is changed to match the pWWN
21:01:01:01:01:01:01:03 on switch-2: switch-1# configure
Enter configuration commands, one per line. End with CNTL/Z.
switch-1(config)# device-alias database switch-1(config-device-alias-db)# no device-alias name A1 switch-1(config-device-alias-db)# show device-alias database | i A1
172
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Distributing Device Alias Services
Resolving Duplicate pWWNs (Different Device Alias Names, Same pWWN)
Step 5
Step 6
Step 7 switch-1(config-device-alias-db)# device-alias name A1 pwwn 21:01:01:01:01:01:01:03 switch-1(config-device-alias-db)# show device-alias database | i A1 device-alias name A1 pwwn 21:01:01:01:01:01:01:03
If there are more duplicate device-alias names, perform step
and step
to resolve the duplicate device-alias names issue.
Use the device-alias distribute command to enable the device-alias distribution and initiate a merge: switch-1(config)# device-alias distribute
Use the show cfs merge status name device-alias command to verify in the output if the merge was successful.
Resolving Duplicate pWWNs (Different Device Alias Names, Same pWWN)
To verify that the same pWWN is mapped to different device-alias names in fabrics, perform these steps:
Step 1
Step 2
Step 3
Run the show device-alias merge status command to identify if the reason for the merge failure is a database mismatch: switch# show device-alias merge status
Result: Failure
Reason: Another device-alias already present with the same pwwn.
Note A properly merged device-alias application should only show a single merge master. If there is more than one merge master, as shown in the above example, it indicates that the device-alias databases are not merged.
Review the CFS or the device-alias merge failure syslog to confirm that the merge failed. Alternatively, run the show cfs merge status name device-alias command to view the status of the merge: switch# show cfs merge status name device-alias
Physical-fc Merge Status: Failed [ Mon Apr 9 15:57:58 2007 ] <===Merge status
Local Fabric
-------------------------------------------------------------------------
Switch WWN IP Address
-------------------------------------------------------------------------
[Merge Master] <<< Merge Master#1 20:00:00:0d:ec:2f:c1:40 172.20.150.38
switch-1
Total number of switches = 1
Remote Fabric
-------------------------------------------------------------------------
Switch WWN IP Address
-------------------------------------------------------------------------
20:00:00:0d:ec:04:99:40 172.20.150.30
switch-2
[Merge Master] <<< Merge Master#2
Total number of switches = 1
Depending on the Cisco MDS NX-OS release your switch is using, run one of the following commands:
• Cisco MDS NX-OS Release 8.1(1) and later releases
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
173
Distributing Device Alias Services
Resolving Duplicate pWWNs (Different Device Alias Names, Same pWWN)
Use the show device-alias merge conflicts command to display the device alias and pWWNs that are causing a merge failure. Use the no device-alias distribute command, followed by the device-alias distribute command to update the information about the merge conflicts.
Note Run the show device-alias merge conflicts command from a switch listed as a merge master.
In the following example, the pWWN 21:01:01:01:01:01:01:02 is mapped to device-alias A3 on switch-1, and to device-alias A1 on switch-2: switch-1# show device-alias merge conflicts
Merge Status : Failure
Peer Switch SWWN : 20:00:00:0d:ec:24:f5:00
Conflicts :
1. Conflicting Device-aliases : 1
-------------------------------------------------------------------------
Local Device-alias Peer Device-alias PWWN
-------------------------------------------------------------------------
A3 A1 pwwn 21:01:01:01:01:01:01:02
• Cisco MDS NX-OS Release 7.3 and earlier releases
Compare the device-alias databases manually to identify the pWWNs that are causing a merge failure.
On the switches where the merge failed in step
show device-alias database command to identify if a pWWN that is mapped to two different device-alias names exists.
In this example, the pWWN 21:01:01:01:01:01:01:02 is mapped to the device-alias A3 on switch-1 and to the device-alias A1 on switch-2: switch-1# show device-alias database device-alias name A3 pwwn 21:01:01:01:01:01:01:02
Total number of entries = 1 switch-2# show device-alias database device-alias name A1 pwwn 21:01:01:01:01:01:01:02
Step 4
Step 5
Step 6
Run the device-alias name name pwwn id command to change the device-alias name on one of the switches to match the device-alias name on the other switch.
Note Perform this step after device-alias distribution is disabled by running the no device-alias distribute command.
In the following example, the device-alias name A3 on switch-1 is changed to match the device-alias name A1 on switch-2: switch-1# configure
Enter configuration commands, one per line. End with CNTL/Z.
switch-1(config)# device-alias database switch-1(config-device-alias-db)# no device-alias name A3 switch-1(config-device-alias-db)# device-alias name A1 pwwn 21:01:01:01:01:01:01:02
If there are more duplicate device-alias names, perform step
and step
to resolve the duplicate device-alias names issue.
Use the device-alias distribute command to enable the device-alias distribution and initiate a merge: switch-1(config)# device-alias distribute
174
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Distributing Device Alias Services
Resolving Mode Mismatch
Step 7 Use the show cfs merge status name device-alias command to verify in the output if the merge was successful.
Resolving Mode Mismatch
The Device Alias feature can operate in either Basic or Enhanced mode. If the modes are different in two fabrics, CFS merge between the fabrics fails.
To verify that the device-alias mode is different in two fabrics, perform these steps:
Step 1 Review the CFS or device-alias merge failure syslog to confirm that the merge failed. Alternatively, run the show cfs merge status name device-alias command to view the status of the merge.
switch# show cfs merge status name device-alias
Physical-fc Merge Status: Failed [ Mon Apr 9 15:57:58 2007 ] <===Merge status
Local Fabric
-------------------------------------------------------------------------
Switch WWN IP Address
-------------------------------------------------------------------------
20:00:00:0d:ec:2f:c1:40 172.20.150.38
[Merge Master] <<< Merge Master#1 switch-1
Total number of switches = 1
Remote Fabric
-------------------------------------------------------------------------
Switch WWN IP Address
-------------------------------------------------------------------------
20:00:00:0d:ec:04:99:40 172.20.150.30
switch-2
[Merge Master] <<< Merge Master#2
Total number of switches = 1
Step 2
Step 3
Use the show device-alias merge status command to verify that the reason for the merge failure is a mode mismatch.
If there is a mode mismatch, the reason that is displayed in the output is either " Databases could not be merged due to mode mismatch " or " One of the merging fabrics cannot support device-alias
Enhanced mode.
" switch# show device-alias merge status
Result: Failure
Reason: Databases could not be merged due to mode mismatch.
Use the show device-alias status command to verify the device-alias mode for each of the fabric.
In this example, switch-1 is running in Enhanced mode, while switch-2 is running in Basic mode: switch-1# show device-alias status
Fabric Distribution: Enabled
Database:- Device Aliases 2 Mode: Enhanced switch-2# show device-alias status
Fabric Distribution: Enabled
Database:- Device Aliases 2 Mode: Basic
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
175
Distributing Device Alias Services
Resolving a Validation Failure
Step 4
Step 5
Use the no device-alias distribute command to disable device-alias distribution after you detect mismatched device-alias modes.
Depending on the mode you want to change in the switch, use the device-alias mode enhanced command to change to enhanced mode, or use the no device-alias mode enhanced command to change the switch mode to basic mode.
Note • Prior to Cisco MDS NX-OS Release 8.5(1), the default device alias mode was basic mode. From Cisco
MDS NX-OS Release 8.5(1), the default device alias mode is enhanced mode.
• If you want to change the device-alias mode from Enhanced to Basic, but an application contains a device-alias configuration in the native format, the device-alias mode cannot be changed until you explicitly remove all the native device-alias configurations or replace all the device-alias members with the corresponding pWWNs.
Step 6 Use the device-alias distribute command to enable the device-alias distribution and initiate a merge.
Resolving a Validation Failure
If the merger of device aliases takes place without any conflicts, the resultant device-alias database is validated with the registered applications on each switch in both the fabrics being merged. If an application fails the validation of the merged database for any reason, the device-alias merge fails.
To verify that the device-alias database merge is failing because of an application-validation failure, perform these steps:
Step 1
Step 2
Step 3
Review the CFS or device-alias merge failure syslog to confirm that the merge failed. Alternatively, run the show cfs merge status name device-alias command to view the status of the merge.
Use the show device-alias merge status command to verify that the reason for the merge failure is an application-validation failure: switch# show device-alias merge status
Result: Failure
Reason: This is a non device-alias error.
Examine the syslog messages. The syslog for the switch in which the validation is rejected and the syslog for the switch managing the merge show relevant error messages.
This example shows a sample message on a switch in which the validation is rejected:
2007 Apr 10 00:00:06 switch-2 %DEVICE-ALIAS-3-MERGE_VALIDATION_REJECTED:
Failed SAP: 110 Reason: inter-VSAN zone member cannot be in more than one
VSAN Expln:
This example shows the syslog message on a switch that is managing the merge, and in which the validation is rejected:
2007 Apr 9 16:41:22 switch-1 %DEVICE-ALIAS-3-MERGE_VALIDATION_FAILED: Failed
SWWN: 20:00:00:0d:ec:04:99:40 Failed SAP: 110 Reason: inter-VSAN zone member cannot be in more than one
VSAN Expln:
176
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Distributing Device Alias Services
Resolving a Validation Failure
Step 4
Step 5
Step 6
Use the show device-alias internal validation-info command on the switch managing the merge, and examine the output.
This example shows that SAP 110 on switch 20:00:00:0d:ec:04:99:40 (switch-2) rejected the validation. The status message shows the reason for the failure along with the system application number: switch# show device-alias internal validation-info
Validation timer:
Per SAP Info Table:
===================
0s
SAPS: 0
MTS Buffer Array Details:
=========================
Buffers: 0
Local Status:
=============
Num Reqs Sent: 0 20:00:00:0d:ec:04:99:40
Num SAPs Done: 0
Failed SAP : 0
Remote Status:
==============
CFS Resp Rcvd: TRUE
Status: success Expln:
Failed SWWN : 20:00:00:0d:ec:04:99:40
SAP : 110 Status: inter-VSAN zone member cannot be in more than one VSAN <=== Status
Expln:
Use the show system internal mts sup sap number description command to find the application that rejected the configuration on the switch that rejected the validation.
In this example, the application that rejected the device-alias validation was the IVR process.
switch#
IVR-SAP show system internal mts sup sap 110 description
Analyze the device-alias validation failure. This analysis is dependent on the application that failed the validation as well as the device-alias database configuration.
In this example, IVR is failing the validation. To troubleshoot this problem, begin by reviewing the device-alias databases that are being merged. Use the show device-alias database command from the switch managing the merge for each fabric.
switch# show device-alias database device-alias name A1 pwwn 21:01:01:01:01:01:01:01 device-alias name A2 pwwn 21:01:01:01:01:01:01:02 => Pre-merge: A2 defined on switch-1
Total number of entries = 2 switch# show device-alias database device-alias name A1 pwwn 21:01:01:01:01:01:01:01 => Pre-merge: A2 not defined on switch-2
Total number of entries = 1
Because IVR is enabled on switch-2, review the IVR zone set.
switch# show ivr zoneset zoneset name s1 zone name z1 pwwn 21:01:01:01:01:01:01:02 vsan device-alias A2 vsan
1 autonomous-fabric-id
2 autonomous-fabric-id
1
1
Prior to the database merge, device-alias A2 is not defined on switch-2. Because of the merge between switch-1 and switch-2, device-alias A2 becomes available on switch-2, and A2 is mapped to pWWN 21:01:01:01:01:01:01:02.
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
177
Distributing Device Alias Services
Resolving Database Conflicts
The device alias-based member A2 in the IVR zone z1 is resolved and mapped to pWWN 21:01:01:01:01:01:01:02, and is a member of VSAN 2. However, pWWN 21:01:01:01:01:01:01:02 is already a member of VSAN 1. The mapping that occurs because of the device-alias merge makes the IVR configuration illegal. The same pWWN cannot be a member of multiple VSANs.
In the case when IVR configuration is illegal, the pWWN in VSAN 2 is defined using the device alias (A2), while the member in VSAN 1 is defined using the actual pWWN. The IVR detects this situation and rejects the device-alias validation. As a result, the device-alias merge fails.
Resolving Database Conflicts
If an entry in the device-alias database conflicts with the configuration of a registered application, the device-alias database commit fails the validation process. Correct either the device-alias database or the application configuration.
To determine the application that failed the validation and the reason for the failure, perform these steps:
Step 1
Step 2
Step 3
Step 4
Use the device-alias commit command to view the output.
This example shows that the commit failed because there is a conflict between the device-alias database and an application configuration: switch# configure terminal
Enter configuration commands, one per line.
End with CNTL/Z.
switch(config)# device-alias commit inter-VSAN zone member cannot be in more than one VSAN ===> reason for commit failure
Determine which application configuration is in conflict with the device-alias database by reviewing the syslogs for the switch in which the commit was issued.
This example shows that SAP 110 (IVR) on sWWN 20:00:00:0d:ec:04:99:40 (switch-2) has rejected the validation, and therefore, the device-alias commit has failed:
2007 Apr 10 11:54:24 switch-1 %DEVICE-ALIAS-3-VALIDATION_FAILED: Failed=>Validation Status
SWWN: 20:00:00:0d:ec:04:99:40 Failed SAP: 110 Reason: inter-VSAN zone ==>Switch and SAP member cannot be in more than one VSAN Expln: ==>Reason
2007 Apr 10 11:54:24 switch-1 %DEVICE-ALIAS-3-COMMIT_FAILED: Failed to ==>Commit status commit the pending database: inter-VSAN zone member cannot be in more ==>Reason than one VSAN
Review the syslog on the switch in which the validation is rejected.
This example shows that the following syslog is printed on switch-2:
2007 Apr 10 19:13:08 switch-2 %DEVICE-ALIAS-3-VALIDATION_REJECTED: Failed
SAP: 110 Reason: inter-VSAN zone member cannot be in more than one VSAN ==>SAP and reason
Compare the existing device-alias database (including the desired changes) and the application configuration to find the conflict.
178
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Distributing Device Alias Services
Verifying the Device-Alias Database Status
Step 5
This example uses the show device-alias database and show ivr zoneset commands along with the console logs of the device-alias database changes made prior to the commit. The comparison shows that the definition of the new device-alias
A2 results in the resolution of the enhanced device-alias member A2 in the IVR zone z1 to pWWN 21:01:01:01:01:01:01:02, which is already a member of zone z1. The pWWN is directly defined as a member of VSAN 1, while the enhanced device-alias A2 is defined as a member of VSAN 2. This configuration is not allowed in the IVR. The IVR detects the configuration problem and rejects the device-alias database validation.
switch# show device-alias database ===> existing device alias database device-alias name A1 pwwn 21:01:01:01:01:01:01:01
Total number of entries = 1 switch# show ivr zoneset ===> display existing IVR zone set zoneset name s1 zone name z1 pwwn 21:01:01:01:01:01:01:02 vsan device-alias A2 switch# configure terminal
1 autonomous-fabric-id vsan
1
2 autonomous-fabric-id 1
Enter configuration commands, one per line.
End with CNTL/Z.
switch(config)# device-alias database switch(config-device-alias-db)# device-alias name A2 pwwn 21:01:01:01:01:01:01:02 switch(config-device-alias-db)# exit switch(config)# device-alias commit inter-VSAN zone member cannot be in more than one VSAN
Correct the conflict by making adjustments to the application configuration, or by making changes to the device-alias database, and running the device-alias commit command again.
Verifying the Device-Alias Database Status
This section provides information about verifying the device-alias database status.
Table 16: Verifying the Device-Alias Database Status
Command Name show cfs merge status name device-alias show device-alias database show device-alias internal validation info show device-alias merge conflicts show device-alias merge status show device-alias session status
Description
Displays information about the status of the CFS merge for the device-alias database.
Displays the entire device-alias database.
Displays information about the status of the validation process (part of a commit or merge).
Displays the device-alias names or pWWNs causing a merge failure in Cisco MDS NX-OS Release 8.1(1) and later releases.
Displays the result of the device-alias merge operation and the reason for the result.
Returns the status of the last CFS command, such as clear , commit , or terminate . The results of the last used CFS command and reason fields help identify the reason for the failure.
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
179
Verifying the Device-Alias Database Status
Command Name show device-alias status
Distributing Device Alias Services
Description
Displays configuration information for the device-alias service, including whether fabric distribution is enabled, the number of device aliases in the database, lock information, and the database mode (Basic or
Enhanced).
180
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
C H A P T E R
7
Configuring Fibre Channel Routing Services and
Protocols
Fabric Shortest Path First (FSPF) is the standard path selection protocol used by Fibre Channel fabrics. The
FSPF feature is enabled by default on all Fibre Channel switches. Except in configurations that require special consideration, you do not need to configure any FSPF services. FSPF automatically calculates the best path between any two switches in a fabric. Specifically, FSPF is used to:
• Dynamically compute routes throughout a fabric by establishing the shortest and quickest path between any two switches.
• Select an alternative path in the event of the failure of a given path. FSPF supports multiple paths and automatically computes an alternative path around a failed link. It provides a preferred route when two equal paths are available.
This chapter provides details on Fibre Channel routing services and protocols. It includes the following sections:
•
•
FSPF Global Configuration, on page 184
•
FSPF Interface Configuration, on page 186
•
•
•
In-Order Delivery, on page 196
•
Flow Statistics Configuration, on page 200
•
About FSPF
FSPF is the protocol currently standardized by the T11 committee for routing in Fibre Channel networks. The
FSPF protocol has the following characteristics and features:
• Supports multipath routing.
• Bases path status on a link state protocol.
• Routes hop by hop, based only on the domain ID.
• Runs only on E ports or TE ports and provides a loop free topology.
• Runs on a per VSAN basis. Connectivity in a given VSAN in a fabric is guaranteed only for the switches configured in that VSAN.
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
181
Configuring Fibre Channel Routing Services and Protocols
FSPF Examples
• Uses a topology database to keep track of the state of the links on all switches in the fabric and associates a cost with each link.
• Guarantees a fast reconvergence time in case of a topology change. Uses the standard Dijkstra algorithm, but there is a static dynamic option for a more robust, efficient, and incremental Dijkstra algorithm. The reconvergence time is fast and efficient as the route computation is done on a per VSAN basis.
FSPF Examples
This section provides examples of topologies and applications that demonstrate the benefits of FSPF.
Note The FSPF feature can be used on any topology.
Fault Tolerant Fabric
Figure 43: Fault Tolerant Fabric, on page 182
depicts a fault tolerant fabric using a partial mesh topology. If a link goes down anywhere in the fabric, any switch can still communicate with all others in the fabric. In the same way, if any switch goes down, the connectivity of the rest of the fabric is preserved.
Figure 43: Fault Tolerant Fabric
For example, if all links are of equal speed, the FSPF calculates two equal paths from A to C: A-D-C (green) and A-E-C (blue).
Redundant Links
To further improve on the topology in
Figure 43: Fault Tolerant Fabric, on page 182 , each connection between
any pair of switches can be replicated; two or more links can be present between a pair of switches
Fault Tolerant Fabric with Redundant Links, on page 183
shows this arrangement. Because switches in the
Cisco MDS 9000 Family support PortChanneling, each pair of physical links can appear to the FSPF protocol as one single logical link.
By bundling pairs of physical links, FSPF efficiency is considerably improved by the reduced database size and the frequency of link updates. Once physical links are aggregated, failures are not attached to a single link but to the entire PortChannel. This configuration also improves the resiliency of the network. The failure of a link in a PortChannel does not trigger a route change, thereby reducing the risks of routing loops, traffic loss, or fabric downtime for route reconfiguration.
182
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Configuring Fibre Channel Routing Services and Protocols
Figure 44: Fault Tolerant Fabric with Redundant Links
Failover Scenarios for PortChannels and FSPF Links
For example, if all links are of equal speed and no PortChannels exist, the FSPF calculates four equal paths from A to C: A1-E-C, A2-E-C, A3-D-C, and A4-D-C. If PortChannels exist, these paths are reduced to two.
Failover Scenarios for PortChannels and FSPF Links
The SmartBits traffic generator was used to evaluate the scenarios displayed in
ISLs or PortChannels. There is one flow from traffic generator 1 to traffic generator 2. The traffic was tested at 100 percent utilization at 1 Gbps in two scenarios:
• Disabling the traffic link by physically removing the cable (see
Table 17: Physically Removing the Cable for the SmartBits Scenario , on page 183 ).
• Shutting down the links in either switch 1 or switch 2 (see
Table 18: Shutting Down the links in Switch for the SmartBits Scenario , on page 183 ).
Figure 45: Failover Scenario Using Traffic Generators
Table 17: Physically Removing the Cable for the SmartBits Scenario
PortChannel Scenario FSPF Scenario (Equal cost ISL)
Switch 1 Switch 2
110 msec (~2K frame drops)
Switch 1 Switch 2
130+ msec (~4k frame drops)
100 msec (hold time when a signal loss is reported as mandated by the standard)
Table 18: Shutting Down the links in Switch for the SmartBits Scenario
PortChannel Scenario
Switch 1
~0 msec (~8 frame drops)
Switch 2
110 msec (~2K frame drops)
No hold time needed Signal loss on switch 1
FSPF Scenario (Equal cost ISL)
Switch 1 Switch 2
130+ msec (~4K frame drops)
No hold time needed Signal loss on switch 1
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
183
Configuring Fibre Channel Routing Services and Protocols
FSPF Global Configuration
FSPF Global Configuration
By default, FSPF is enabled on switches in the Cisco MDS 9000 Family.
Some FSPF features can be globally configured in each VSAN. By configuring a feature for the entire VSAN, you do not have to specify the VSAN number for every command. This global configuration feature also reduces the chance of typing errors or other minor configuration errors.
Note FSPF is enabled by default. Generally, you do not need to configure these advanced features.
Caution The default for the backbone region is 0 (zero). You do not need to change this setting unless your region is different from the default. If you are operating with other vendors using the backbone region, you can change this default to be compatible with those settings.
This section includes the following topics:
About SPF Computational Hold Times
The SPF computational hold time sets the minimum time between two consecutive SPF computations on the
VSAN. Setting this to a small value means that FSPF reacts faster to any fabric changes by recomputing paths on the VSAN. A small SPF computational hold time uses more switch CPU time.
About Link State Record Defaults
Each time a new switch enters the fabric, a link state record (LSR) is sent to the neighboring switches, and then flooded throughout the fabric.
Table 19: LSR Default Settings , on page 184
displays the default settings for switch responses.
Table 19: LSR Default Settings
LSR Option
Acknowledgment interval
(RxmtInterval)
Refresh time (LSRefreshTime)
Maximum age (MaxAge)
Default Description
5 seconds The time a switch waits for an acknowledgment from the LSR before retransmission.
30 minutes The time a switch waits before sending an LSR refresh transmission.
60 minutes The time a switch waits before dropping the LSR from the database.
The LSR minimum arrival time is the period between receiving LSR updates on this VSAN. Any LSR updates that arrive before the LSR minimum arrival time are discarded.
The LSR minimum interval time is the frequency at which this switch sends LSR updates on a VSAN.
184
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Configuring Fibre Channel Routing Services and Protocols
Configuring FSPF on a VSAN
Configuring FSPF on a VSAN
To configure an FSPF feature for the entire VSAN, follow these steps:
Step 1
Step 2
Step 3
Step 4
Step 5 switch# config terminal switch(config)#
Enters configuration mode.
switch(config)# fspf config vsan 1
Enters FSPF global configuration mode for the specified VSAN.
switch-config-(fspf-config)# spf static
Forces static SPF computation for the dynamic (default) incremental VSAN.
switch-config-(fspf-config)# spf hold-time 10
Configures the hold time between two route computations in milliseconds (msec) for the entire VSAN. The default value is 0.
Note If the specified time is shorter, the routing is faster. However, the processor consumption increases accordingly.
switch-config-(fspf-config)# region 7
Configures the autonomous region for this VSAN and specifies the region ID (7).
Resetting FSPF to the Default Configuration
To return the FSPF VSAN global configuration to its factory default, follow these steps:
Step 1
Step 2 switch# config terminal switch(config)#
Enters configuration mode.
switch(config)# no fspf config vsan 3
Deletes the FSPF configuration for VSAN 3.
Enabling or Disabling FSPF
To enable or disable FSPF routing protocols, follow these steps:
Step 1 switch# config terminal switch(config)#
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
185
Configuring Fibre Channel Routing Services and Protocols
Clearing FSPF Counters for the VSAN
Step 2
Step 3
Enters configuration mode.
switch(config)# fspf enable vsan 7
Enables the FSPF routing protocol in VSAN 7.
switch(config)# no fspf enable vsan 5
Disables the FSPF routing protocol in VSAN 5.
Clearing FSPF Counters for the VSAN
To clear the FSPF statistics counters for the entire VSAN, follow this step: switch# clear fspf counters vsan 1
Clears the FSPF statistics counters for the specified VSAN. If an interface reference is not specified, all counters are cleared.
FSPF Interface Configuration
Several FSPF commands are available on a per-interface basis. These configuration procedures apply to an interface in a specific VSAN.
This section includes the following topics:
About FSPF Link Cost
FSPF tracks the state of links on all switches in the fabric, associates a cost with each link in its database, and then chooses the path with a minimal cost. The cost associated with an interface can be administratively changed to implement the FSPF route selection. The integer value to specify cost can range from 1 to 30000.
The default cost for 1 Gbps is 1000 and for 2 Gbps is 500.
Configuring FSPF Link Cost
To configure FSPF link cost, follow these steps:
Step 1
Step 2 switch# config t switch(config)#
Enters configuration mode.
switch(config)# interface fc1/4 switch(config-if)#
186
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Configuring Fibre Channel Routing Services and Protocols
About Hello Time Intervals
Step 3
Configures the specified interface, or if already configured, enters configuration mode for the specified interface.
switch(config-if)# fspf cost 5 vsan 90
Configures the cost for the selected interface in VSAN 90.
About Hello Time Intervals
You can set the FSPF Hello time interval to specify the interval between the periodic hello messages sent to verify the health of the link. The integer value can range from 1 to 65,535 seconds.
Note This value must be the same in the ports at both ends of the ISL.
Configuring Hello Time Intervals
To configure the FSPF Hello time interval, follow these steps:
Step 1
Step 2
Step 3 switch# config t switch(config)#
Enters configuration mode.
switch(config)# interface fc1/4 switch(config-if)#
Configures the specified interface, or if already configured, enters configuration mode for the specified interface.
switch(config-if)# fspf hello-interval 15 vsan 175 switch(config-if)#
Specifies the hello message interval (15 seconds) to verify the health of the link in VSAN 175. The default is 20 seconds.
About Dead Time Intervals
You can set the FSPF dead time interval to specify the maximum interval for which a hello message must be received before the neighbor is considered lost and removed from the database. The integer value can range from 1 to 65,535 seconds.
Note This value must be the same in the ports at both ends of the ISL.
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
187
Configuring Fibre Channel Routing Services and Protocols
Configuring Dead Time Intervals
• An error is reported at the command prompt if the configured dead time interval is less than the hello time interval
• During a software upgrade, ensure that the fspf dead-interval is greater than the ISSU downtime (80 seconds). If the fspf dead-interval is lesser than the ISSU downtime, the software upgrade fails and the following error is displayed:
Service "fspf" returned error: Dead interval for interface is less than ISSU upgrade time.
Configuring Dead Time Intervals
To configure the FSPF dead time interval, follow these steps:
Step 1
Step 2
Step 3 switch# config terminal switch(config)#
Enters configuration mode.
switch(config)# interface fc1/4 switch(config-if)#
Configures the specified interface, or if already configured, enters configuration mode for the specified interface.
switch(config-if)# fspf dead-interval 25 vsan 7 switch(config-if)#
Specifies the maximum interval for VSAN 7 before which a hello message must be received on the selected interface before the neighbor is considered lost. The default is 80 seconds.
About Retransmitting Intervals
You can specify the time after which an unacknowledged link state update should be transmitted on the interface. The integer value to specify retransmit intervals can range from 1 to 65,535 seconds.
Note This value must be the same on the switches on both ends of the interface.
Configuring Retransmitting Intervals
To configure the FSPF retransmit time interval, follow these steps:
Step 1 switch# config terminal switch(config)#
Enters configuration mode.
188
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Configuring Fibre Channel Routing Services and Protocols
About Disabling FSPF for Specific Interfaces
Step 2
Step 3 switch(config)# interface fc1/4 switch(config-if)#
Configures the specified interface, or if already configured, enters configuration mode for the specified interface.
switch(config-if)# fspf retransmit-interval 15 vsan 12 switch(config-if)#
Specifies the retransmit time interval for unacknowledged link state updates in VSAN 12. The default is 5 seconds.
About Disabling FSPF for Specific Interfaces
You can disable the FSPF protocol for selected interfaces. By default, FSPF is enabled on all E ports and TE ports. This default can be disabled by setting the interface as passive.
Note FSPF must be enabled at both ends of the interface for the protocol to work.
Disabling FSPF for Specific Interfaces
You can disable the FSPF protocol for selected interfaces. By default, FSPF is enabled on all E ports and TE ports. This default can be disabled by setting the interface as passive.
To disable FSPF for a specific interface, follow these steps:
Step 1
Step 2
Step 3
Step 4 switch# config terminal switch(config)#
Enters configuration mode.
switch(config)# interface fc1/4 switch(config-if)#
Configures a specified interface, or if already configured, enters configuration mode for the specified interface.
switch(config-if)# fspf passive vsan 1 switch(config-if)#
Disables the FSPF protocol for the specified interface in the specified VSAN.
switch(config-if)# no fspf passive vsan 1 switch(config-if)#
Reenables the FSPF protocol for the specified interface in the specified VSAN.
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
189
Configuring Fibre Channel Routing Services and Protocols
Clearing FSPF Counters for an Interface
You can disable the FSPF protocol for selected interfaces. By default, FSPF is enabled on all E ports and TE ports. This default can be disabled by setting the interface as passive.
Clearing FSPF Counters for an Interface
To clear the FSPF statistics counters for an interface, follow this step: switch# clear fspf counters vsan 200 interface fc1/1
Clears the FSPF statistics counters for the specified interface in VSAN 200.
FSPF Routes
FSPF routes traffic across the fabric, based on entries in the FSPF database. These routes can be learned dynamically, or configured statically.
This section includes the following topics:
About Fibre Channel Routes
Each port implements forwarding logic, which forwards frames based on its FC ID. Using the FC ID for the specified interface and domain, you can configure the specified route (for example FC ID 111211 and domain
ID 3) in the switch with domain ID 1 (see
Figure 46: Fibre Channel Routes, on page 190 ).
Figure 46: Fibre Channel Routes
Note Other than in VSANs, runtime checks are not performed on configured and suspended static routes.
About Broadcast and Multicast Routing
Broadcast and multicast in a Fibre Channel fabric uses the concept of a distribution tree to reach all switches in the fabric.
190
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Configuring Fibre Channel Routing Services and Protocols
About Multicast Root Switch
FSPF provides the topology information to compute the distribution tree. Fibre Channel defines 256 multicast groups and one broadcast address for each VSAN. Switches in the Cisco MDS 9000 Family only use broadcast routing. By default, they use the principal switch as the root node to derive a loop-free distribution tree for multicast and broadcast routing in a VSAN.
Caution All switches in the fabric should run the same multicast and broadcast distribution tree algorithm to ensure the same distribution tree.
To interoperate with other vendor switches (following FC-SW3 guidelines), the SAN-OS and NX-OS 4.1(1b) and later software uses the lowest domain switch as the root to compute the multicast tree in interop mode.
About Multicast Root Switch
By default, the native (non-interop) mode uses the principal switch as the root. If you change the default, be sure to configure the same mode in all switches in the fabric. Otherwise, multicast traffic could encounter potential loop and frame-drop problems.
Note The operational mode can be different from the configured interop mode. The interop mode always uses the lowest domain switch as the root.
Use the mcast root lowest vsan command to change the multicast root from the principal switch to lowest domain switch.
Setting the Multicast Root Switch
To use the lowest domain switch for the multicast tree computation, follow these steps:
Step 1
Step 2
Step 3 switch# config terminal switch(config)#
Enters configuration mode.
switch(config)# mcast root lowest vsan 1
Uses the lowest domain switch to compute the multicast tree.
switch(config)# mcast root principal vsan 1
Defaults to using the principal switch to compute the multicast tree.
To display the configured and operational multicast mode and the selected root domain, use the show mcast command.
switch# show mcast vsan 1
Multicast root for VSAN 1
Configured root mode : Principal switch
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
191
Configuring Fibre Channel Routing Services and Protocols
Load Balancing
Operational root mode : Principal switch
Root Domain ID : 0xef(239)
Load Balancing
Load balancing is a forwarding mechanism that distributes traffic over equal-cost multipath (ECMP) and port channels. Load balancing uses a hash method to identify an egress link. The hash is a function that uses parameters in the frame header to identify a unique link to forward the frame to. The load balancing scheme used depends on both the type of ingress port and egress routing. If it is intended that traffic flow in both directions on the same link, then ensure that the same load balancing scheme and hash method are used at both ends of the link.
Load Balancing Schemes
The following types of load balancing schemes are supported:
• Flow based—All frames between a given source FCID and destination FCID are transmitted on the same link. That is, whichever link is selected for the first exchange between the source-destination pair is used for all subsequent exchanges.
• Exchange based—The first frame in an exchange between a given source FCID and destination FCID is used to select an egress link and subsequent frames in the exchange are transmitted on the same link.
However, subsequent exchanges between the source-destination pair will likely be transmitted on a different link. This provides more granular load balancing while preserving the order of frames within each exchange.
Figure 47: Flow Based Load Balancing, on page 192
illustrates how flow based load balancing works. In this example, when the first frame with a source FCID of sid1 and destination FCID of did1 is received for forwarding, port channel 2 is selected. Each subsequent frame in that flow is sent over the same port channel.
No frame from sid1 to did1 utilizes port channel 1. Similarly, all frames with sid2 and did2 are sent over port channel 1. Exchange ID is not used with this type of load balancing.
Figure 47: Flow Based Load Balancing
Figure 48: Exchange Based Load Balancing, on page 193
illustrates how exchange based load balancing works.
In this example, when the first frame in an exchange between a source FCID sid1 and destination FCID did1
192
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Configuring Fibre Channel Routing Services and Protocols
Hashing Methods is received for forwarding, port channel 2 is selected. All remaining frames in that particular exchange are sent on the same port channel and none are sent on port channel 1. For the next exchange, the hash algorithm chooses port channel 1. So all frames in exchange 2 between the same source-destination pair are sent on port channel 1.
Figure 48: Exchange Based Load Balancing
Hashing Methods
Load balancing is applied to an ingress frame at two levels—At the first level, an ECMP hash is used to select an egress ECMP interface (this can be either a physical interface or logical interface such as a port channel interface) and at the second level, a port channel hash is used to select an egress port channel member.
By default, the hash method that is used depends on the ingress hardware type. If either level of hash does not apply to the egress route, then no hash method is applied.
The following types of hashing methods are supported:
• ECMP Hashing Method—If multiple paths to a destination with equal cost exist in the switch, the FIB for the ingress port is updated with these paths for that destination. This hashing method is used to select one of such paths to send frames to.
• Port Channel Hashing Method—This hashing method is used to select an operational interface of an egress port channel.
Figure 49: ECMP Hashing Method, on page 194
illustrates how the ECMP hash method works. There are two port channels each including two equal speed links. Since the FSPF costs of the port channels are the same, both port channels are used for hashing. In this example, ECMP level hashing method selects port channel 2 as the egress port.
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
193
Hashing Methods
Figure 49: ECMP Hashing Method
Configuring Fibre Channel Routing Services and Protocols
Depending on the type of ingress port, the following subtypes of ECMP hashing methods are supported:
• Type 1a
• Type 1b
For information on which hashing method is selected for a given ingress port, see
Table 20: Hashing Matrix, on page 195 .
Figure 50: Port Channel Hashing Method, on page 194
illustrates how port channel hashing method works.
Continuing the
Figure 49: ECMP Hashing Method, on page 194
example where port channel 2 was selected as the egress port, a port channel hash is subsequently applied to select an egress port within the port channel.
In this example, the frames are transmitted by interface 1/4 of the selected port channel.
Figure 50: Port Channel Hashing Method
Depending on the type of ingress port, the following types of port channel hashing methods are supported:
• Type 2a
• Type 2b
For information on which hashing method is selected for a given ingress port, see
Table 20: Hashing Matrix, on page 195 .
194
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Configuring Fibre Channel Routing Services and Protocols
Hashing Methods
Table 20: Hashing Matrix
Ingress Interface Egress Interface ECMP Hash Method
Fibre Channel or FCIP port on Cisco MDS 9500 with Generation 3 or 4 module
Fibre Channel or FCIP
ISL
Fibre Channel port on
Cisco MDS 9500 with
Generation 3 or 4 module
Fibre Channel ISL
Type 1a
Type 1a
Port Channel Hash
Method
Type 2b (only when at least one FCIP port is up)
Type 2a
Note The hashing method changes to type 2b if FCIP tunnel were brought up in the switch. The hashing method will remain as type
2b even if the
FCIP module is removed until the next switch reload.
Type 2b Fibre Channel, FCIP, or
FCoE port on Cisco MDS
9250i
Fibre Channel, FCIP, or
FCoE ISL
Fibre Channel, FCIP, or
FCoE port on Cisco MDS
9250i
FCIP ISL connected to
Cisco MDS 24/10-Port
SAN Extension Module with FCIP enhanced.
Type 1a
Type 1a
Fibre Channel port on
Cisco MDS 9700
FCIP ISL
Fibre Channel or FCoE
ISL
FCIP port on Cisco MDS
24/10-Port SAN
Extension Module
FCIP ISL
Fibre Channel or FCoE
ISL
Type 1a
Type 1a
Type 1b
Type 1b
FCoE port on Cisco MDS
9700
FCIP ISL
Fibre Channel or FCoE
ISL
Type 1b
Type 1b
Type 1a
Type 1a
Type 2a
Type 1b
Type 2a
Type 1b
Type 2a
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
195
Configuring Fibre Channel Routing Services and Protocols
In-Order Delivery
Ingress Interface Egress Interface
Fibre Channel port on
Cisco MDS 9148S
Fibre Channel port on
Cisco MDS 9396S
Fibre Channel port on
Cisco MDS 9132T
Fibre Channel port on
Cisco MDS 9396T and
9148T
Fibre Channel ISL
ECMP Hash Method
Type 1a
Port Channel Hash
Method
Type 2a
In-Order Delivery
In-Order Delivery (IOD) of data frames guarantees frame delivery to a destination in the same order that they were sent by the originator.
Some Fibre Channel protocols or applications cannot handle out-of-order frame delivery. In these cases, switches in the Cisco MDS 9000 Family preserve frame ordering in the frame flow. The source ID (SID), destination ID (DID), and optionally the originator exchange ID (OX ID) identify the flow of the frame.
On any given switch with IOD enabled, all frames received by a specific ingress port and destined to a certain egress port are always delivered in the same order in which they were received.
Use IOD only if your environment cannot support out-of-order frame delivery.
Tip If you enable the in-order delivery feature, the graceful shutdown feature is not implemented.
This section includes the following topics:
About Reordering Network Frames
When you experience a route change in the network, the new selected path may be faster or less congested than the old route.
Figure 51: Route Change Delivery
196
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Configuring Fibre Channel Routing Services and Protocols
About Reordering PortChannel Frames
In
Figure 51: Route Change Delivery, on page 196
, the new path from Switch 1 to Switch 4 is faster. In this scenario, Frame 3 and Frame 4 may be delivered before Frame 1 and Frame 2.
If the in-order guarantee feature is enabled, the frames within the network are treated as follows:
• Frames in the network are delivered in the order in which they are transmitted.
• Frames that cannot be delivered in order within the network latency drop period are dropped inside the network.
About Reordering PortChannel Frames
When a link change occurs in a PortChannel, the frames for the same exchange flow or the same initiator-target flow can switch from one path to another faster path.
Figure 52: Link Congestion Delivery
In
Figure 52: Link Congestion Delivery, on page 197
, the port of the old path (black dot) is congested. In this scenario, Frame 3 and Frame 4 can be delivered before Frame 1 and Frame 2.
The in-order delivery feature attempts to minimize the number of frames dropped during PortChannel link changes when the in-order delivery is enabled by sending a request to the remote switch on the PortChannel to flush all frames for this PortChannel.
Note Both switches on the PortChannel must be running Cisco SAN-OS Release 3.0(1) for this IOD enhancement, known as Lossless IOD. For earlier releases, IOD waits for the switch latency period before sending new frames.
When the in-order delivery guarantee feature is enabled and a PortChannel link change occurs, the frames crossing the PortChannel are treated as follows:
• Frames using the old path are delivered before new frames are accepted.
• The new frames are delivered through the new path after the switch latency drop period has elapsed and all old frames are flushed.
Frames that cannot be delivered in order through the old path within the switch latency drop period are dropped.
See the
Configuring the Drop Latency Time, on page 199 .
About Enabling In-Order Delivery
You can enable the in-order delivery feature for a specific VSAN or for the entire switch. By default, in-order delivery is disabled on switches in the Cisco MDS 9000 Series.
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
197
Configuring Fibre Channel Routing Services and Protocols
Enabling In-Order Delivery Globally
Note Enabling or disabling the IOD feature does not disrupt traffic.
Tip We recommend that you only enable this feature when devices that cannot handle any out-of-order frames are connected to the fabric. Load-balancing algorithms within the Cisco MDS 9000 Series ensure that frames are delivered in order during normal fabric operation. The load-balancing algorithms based on source FC ID, destination FC ID, and exchange ID are enforced in hardware without any performance degradation. However, if the fabric encounters a failure and this feature is enabled, the recovery will be delayed because of an intentional pausing of fabric forwarding to purge the fabric of resident frames that could potentially be forwarded out-of-order.
Enabling In-Order Delivery Globally
To ensure that the in-order delivery parameters are uniform across all VSANs on an MDS switch, enable in-order delivery globally.
Only enable in-order delivery globally if this is a requirement across your entire fabric. Otherwise, enable
IOD only for the VSANs that require this feature.
Note Enable in-order delivery on the entire switch before performing a downgrade to Cisco MDS SAN-OS Release
1.3(3) or earlier.
To enable in-order delivery for the switch, follow these steps:
Step 1
Step 2
Step 3 switch# config terminal switch(config)#
Enters configuration mode.
switch(config)# in-order-guarantee
Enables in-order delivery in the switch.
switch(config)# no in-order-guarantee
Reverts the switch to the factory defaults and disables the in-order delivery feature.
Enabling In-Order Delivery for a VSAN
When you create a VSAN, that VSAN automatically inherits the global in-order-guarantee value. You can override this global value by enabling or disabling in-order-guarantee for the new VSAN.
To use the lowest domain switch for the multicast tree computation, follow these steps:
198
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Configuring Fibre Channel Routing Services and Protocols
Displaying the In-Order Delivery Status
Step 1
Step 2
Step 3 switch# config terminal switch(config)#
Enters configuration mode.
switch(config)# in-order-guarantee vsan 3452
Enables in-order delivery in VSAN 3452.
switch(config)# no in-order-guarantee vsan 101
Reverts the switch to the factory defaults and disables the in-order delivery feature in VSAN 101.
Displaying the In-Order Delivery Status
Use the show in-order-guarantee command to display the present configuration status: switch# show in-order-guarantee global inorder delivery configuration:guaranteed
VSAN specific settings vsan 1 inorder delivery:guaranteed vsan 101 inorder delivery:not guaranteed vsan 1000 inorder delivery:guaranteed vsan 1001 inorder delivery:guaranteed vsan 1682 inorder delivery:guaranteed vsan 2001 inorder delivery:guaranteed vsan 2009 inorder delivery:guaranteed vsan 2456 inorder delivery:guaranteed vsan 3277 inorder delivery:guaranteed vsan 3451 inorder delivery:guaranteed vsan 3452 inorder delivery:guaranteed
Configuring the Drop Latency Time
You can change the default latency time for a network, a specified VSAN in a network, or for the entire switch.
To configure the network and the switch drop latency time, follow these steps:
Step 1
Step 2
Step 3 switch# configure terminal switch(config)#
Enters configuration mode.
switch(config)# fcdroplatency network 5000
Configures network drop latency time to be 5000 ms for the network. The valid range is 0 to 60000 ms. The default is
2000 ms.
Note The network drop latency must be computed as the sum of all switch latencies of the longest path in the network.
switch(config)# fcdroplatency network 6000 vsan 3
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
199
Configuring Fibre Channel Routing Services and Protocols
Displaying Latency Information
Step 4
Configures network drop latency time to be 6000 ms for VSAN 3.
switch(config)# no fcdroplatency network 4500
Removes the current fcdroplatecy network configuration (4500) and reverts the switch to the factory defaults.
Displaying Latency Information
You can view the configured latency parameters using the show fcdroplatency command (see
Administrative Distance, on page 200
).
Displays Administrative Distance switch# show fcdroplatency switch latency value:500 milliseconds global network latency value:2000 milliseconds
VSAN specific network latency settings vsan 1 network latency:5000 milliseconds vsan 2 network latency:2000 milliseconds vsan 103 network latency:2000 milliseconds vsan 460 network latency:500 milliseconds
Flow Statistics Configuration
Flow statistics count the ingress traffic in the aggregated statistics table. You can collect two kinds of statistics:
• Aggregated flow statistics to count the traffic for a VSAN.
• Flow statistics to count the traffic for a source and destination ID pair in a VSAN.
This section includes the following topics:
About Flow Statistics
If you enable flow counters, you can enable a maximum of 1 K entries for aggregate flow and flow statistics for Generation 1 modules, and 2 K entries for Generation 2 modules. Be sure to assign an unused flow index to a module for each new flow. Flow indexes can be repeated across modules. The number space for flow index is shared between the aggregate flow statistics and the flow statistics.
Generation 1 modules allow a maximum of 1024 flow statements per module. Generation 2 modules allow a maximum of 2048-128 flow statements per module.
Note For each session, fcflow counter will increment only on locally connected devices and should be configured on the switch where the initiator is connected.
200
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Configuring Fibre Channel Routing Services and Protocols
Counting Aggregated Flow Statistics
Counting Aggregated Flow Statistics
To count the aggregated flow statistics for a VSAN, follow these steps:
Step 1
Step 2
Step 3 switch# config t switch(config)#
Enters configuration mode.
switch(config)# fcflow stats aggregated module 1 index 1005 vsan 1 switch(config)#
Enables the aggregated flow counter.
switch(config)# no fcflow stats aggregated module 1 index 1005 vsan 1 switch(config)#
Disables the aggregated flow counter.
Counting Individual Flow Statistics
To count the flow statistics for a source and destination FC ID in a VSAN, follow these steps:
Step 1
Step 2
Step 3 switch# config t switch(config)#
Enters configuration mode.
switch(config)# fcflow stats module 1 index 1 0x145601 0x5601ff 0xffffff vsan 1 switch(config)#
Enables the flow counter.
Note The source ID and the destination ID are specified in FC ID hex format (for example, 0x123aff). The mask can be one of 0xff0000 or 0xffffff.
switch(config)# no fcflow stats aggregated module 2 index 1001 vsan 2 switch(config)#
Disables the flow counter.
Clearing FIB Statistics
Use the clear fcflow stats command to clear the aggregated flow counter (see Examples
and
Clears Flow Counters for Source and Destination FC IDs, on page 202
).
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
201
Configuring Fibre Channel Routing Services and Protocols
Displaying Flow Statistics
Clears Aggregated Flow Counters switch# clear fcflow stats aggregated module 2 index 1
Clears Flow Counters for Source and Destination FC IDs switch# clear fcflow stats module 2 index 1
Displaying Flow Statistics
Use the show fcflow stats commands to view flow statistics (see Example
Displays Aggregated Flow Details for the Specified Module, on page 202
to
Displays Flow Index Usage for the Specified Module, on page 202 ).
Displays Aggregated Flow Details for the Specified Module switch# show fcflow stats aggregated module 6
Idx VSAN frames bytes
---- ---- --------
1 800 20185860
-------
1211151600
Displays Flow Details for the Specified Module switch# show fcflow stats module 6
Idx
---- -----------
2
VSAN
800
DID
0x520400
SID Mask
-----frames
-----
0x530260 0xffffff bytes
----------
20337793 1220267580
Displays Flow Index Usage for the Specified Module switch# show fcflow stats usage module 6
Configured flows for module 6: 1-2
Displaying Global FSPF Information
Displays FSPF Information for a Specified VSAN, on page 203
displays global FSPF information for a specific
VSAN:
• Domain number of the switch.
• Autonomous region for the switch.
• Min_LS_arrival: minimum time that must elapse before the switch accepts LSR updates.
• Min_LS_interval: minimum time that must elapse before the switch can transmit an LSR.
202
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Configuring Fibre Channel Routing Services and Protocols
Displaying the FSPF Database
Tip If the Min_LS_interval is higher than 10 seconds, the graceful shutdown feature is not implemented.
• LS_refresh_time: interval time lapse between refresh LSR transmissions.
• Max_age: maximum time aa LSR can stay before being deleted.
Displays FSPF Information for a Specified VSAN switch# show fspf vsan 1
FSPF routing for VSAN 1
FSPF routing administration status is enabled
FSPF routing operational status is UP
It is an intra-domain router
Autonomous region is 0
SPF hold time is 0 msec
MinLsArrival = 1000 msec , MinLsInterval = 5000 msec
Local Domain is 0x65(101)
Number of LSRs = 3, Total Checksum = 0x0001288b
Protocol constants :
LS_REFRESH_TIME = 1800 sec
MAX_AGE = 3600 sec
Statistics counters :
Number of LSR that reached MaxAge = 0
Number of SPF computations = 7
Number of Checksum Errors = 0
Number of Transmitted packets : LSU 65 LSA 55 Hello 474 Retranmsitted LSU 0
Number of received packets : LSU 55 LSA 60 Hello 464 Error packets 10
Displaying the FSPF Database
Displays FSPF Database Information, on page 203
displays a summary of the FSPF database for a specified
VSAN. If other parameters are not specified, all LSRs in the database are displayed:
• LSR type
• Domain ID of the LSR owner
• Domain ID of the advertising router
• LSR age
• LSR incarnation member
• Number of links
You could narrow the display to obtain specific information by issuing additional parameters for the domain
ID of the LSR owner. For each interface, the following information is also available:
• Domain ID of the neighboring switch
• E port index
• Port index of the neighboring switch
• Link type and cost
Displays FSPF Database Information switch# show fspf database vsan 1
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
203
Configuring Fibre Channel Routing Services and Protocols
Displaying FSPF Interfaces
FSPF Link State Database for VSAN 1 Domain 0x0c(12)
LSR Type = 1
Advertising domain ID = 0x0c(12)
LSR Age = 1686
LSR Incarnation number = 0x80000024
LSR Checksum
Number of links
= 0x3caf
= 2
NbrDomainId IfIndex NbrIfIndex Link Type Cost
-----------------------------------------------------------------------------
0x65(101) 0x0000100e 0x00001081 1 500
0x65(101) 0x0000100f 0x00001080
FSPF Link State Database for VSAN 1 Domain 0x65(101)
1 500
LSR Type = 1
Advertising domain ID = 0x65(101)
LSR Age = 1685
LSR Incarnation number = 0x80000028
LSR Checksum = 0x8443
Number of links
NbrDomainId
= 6
IfIndex NbrIfIndex Link Type Cost
-----------------------------------------------------------------------------
0xc3(195) 0x00001085
0xc3(195) 0x00001086
0xc3(195) 0x00001087
0xc3(195) 0x00001084
0x0c(12) 0x00001081
0x00001095
0x00001096
0x00001097
0x00001094
0x0000100e
0x0c(12) 0x00001080 0x0000100f
FSPF Link State Database for VSAN 1 Domain 0xc3(195)
1
1
1
1
1
1
500
500
500
500
500
500
LSR Type = 1
Advertising domain ID = 0xc3(195)
LSR Age = 1686
LSR Incarnation number = 0x80000033
LSR Checksum = 0x6799
Number of links
NbrDomainId
= 4
IfIndex NbrIfIndex Link Type Cost
-----------------------------------------------------------------------------
0x65(101) 0x00001095
0x65(101) 0x00001096
0x65(101) 0x00001097
0x65(101) 0x00001094
0x00001085
0x00001086
0x00001087
0x00001084
1
1
1
1
500
500
500
500
Displaying FSPF Interfaces
Displays FSPF Interface Information, on page 204
displays the following information for each selected interface.
• Link cost
• Timer values
• Neighbor’s domain ID (if known)
• Local interface number
• Remote interface number (if known)
• FSPF state of the interface
• Interface counters
Displays FSPF Interface Information switch# show fspf vsan 1 interface fc1/1
FSPF interface fc1/1 in VSAN 1
FSPF routing administrative state is active
204
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Configuring Fibre Channel Routing Services and Protocols
Default Settings
Interface cost is 500
Timer intervals configured, Hello 20 s, Dead 80 s, Retransmit 5 s
FSPF State is FULL
Neighbor Domain Id is 0x0c(12), Neighbor Interface index is 0x0f100000
Statistics counters :
Number of packets received : LSU 8 LSA 8 Hello 118 Error packets 0
Number of packets transmitted : LSU 8 LSA 8 Hello 119 Retransmitted LSU 0
Number of times inactivity timer expired for the interface = 0
Default Settings
Table 21: Default FSPF Settings , on page 205
lists the default settings for FSPF features.
Table 21: Default FSPF Settings
Parameters
FSPF
SPF computation
SPF hold time
Default
Enabled on all E ports and TE ports.
Dynamic.
0.
Backbone region 0.
Acknowledgment interval (RxmtInterval) 5 seconds.
Refresh time (LSRefreshTime)
Maximum age (MaxAge)
30 minutes.
60 minutes.
Hello interval
Dead interval
Distribution tree information
Routing table
Load balancing
In-order delivery
Drop latency
Static route cost
Remote destination switch
Multicast routing
20 seconds.
80 seconds.
Derived from the principal switch (root node).
FSPF stores up to 16 equal cost paths to a given destination.
Based on destination ID and source ID on different, equal cost paths.
Disabled.
Disabled.
If the cost (metric) of the route is not specified, the default is 10.
If the remote destination switch is not specified, the default is direct.
Uses the principal switch to compute the multicast tree.
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
205
Default Settings
Configuring Fibre Channel Routing Services and Protocols
206
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
C H A P T E R
8
Managing FLOGI, Name Server, FDMI, and RSCN
Databases
This chapter describes the fabric login (FLOGI) database, the name server features, the Fabric-Device
Management Interface, and Registered State Change Notification (RSCN) information provided in the Cisco
MDS 9000 Family. It includes the following sections:
•
•
•
•
•
•
•
•
Enabling Port Pacing , on page 236
About FLOGI
In a Fibre Channel fabric, each host or disk requires an Fibre Channel ID. Use the show flogi database command to verify if a storage device is displayed in the FLOGI table as in the next section. If the required device is displayed in the FLOGI table, the fabric login is successful. Examine the FLOGI database on a switch that is directly connected to the host HBA and connected ports.
FLOGI Scale Optimization
The FLOGI scale optimization feature enables MDS switches to support an increased number of FLOGIs for module and chassis. The FLOGI scale optimization preloads the routing information for devices after a switch or module reload. This can speed up the Accepts to FLOGIs. This feature is supported on all MDS switches, except Cisco MDS 9250i Multiservice Fabric Switch and Cisco MDS 9148S 16G Multilayer Fabric Switch, and is enabled by default, starting from Cisco MDS NX-OS Release 8.1(1). As of Cisco MDS Release 8.2(2), the higher FLOGI scale limits are published only for MDS 9718. For more information see the " Cisco MDS
NX-OS Configuration Limits " documentation for the FLOGI limits.
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
207
Managing FLOGI, Name Server, FDMI, and RSCN Databases
FLOGI Quiesce Timeout
FLOGI Quiesce Timeout
The FLOGI Quiesce Timeout feature causes the FLOGI process to delay notifications to the other Fibre
Channel services such as Routing Information and Fibre Channel Name Server when a device logs out from a fabric or when an interface goes down. If the device logs back to the fabric within the FLOGI quiesce timeout value, the FLOGI Accept can be immediately returned without the other Fibre Channel services being notified.
This feature must be disabled by setting the timeout value to zero when there are devices in the fabric that can share a pWWN at different times by logging into different switches within the fabric during failover situations.
Restrictions
• Downgrading from Cisco MDS NX-OS Release 8.1(1) to an earlier release is not supported when FLOGI
Scale Optimization is enabled. This feature must be disabled before downgrading. For more information on disabling this feature, see the
Disabling FLOGI Scale Optimization and Quiesce Timeout
section.
• In Cisco MDS NX-OS Releases 8.1 and Release 8.2, the default FLOGI quiesce timeout value is 2000 ms.
However, starting with Cisco MDS NX-OS Release 8.3(1), the default FLOGI quiesce timeout value was changed from 2000 ms to 0 ms. Any configured FLOGI quiesce timeout value will be maintained on upgrading. If the FLOGI quiesce timeout value is not configured when upgrading to Cisco MDS
NX-OS Releases 8.3(1) or later release, the new default value of 0 ms will be used.
• This feature is supported on all MDS switches, except Cisco MDS 9250i Multiservice Fabric Switch and
Cisco MDS 9148S 16G Multilayer Fabric Switch.
• Cisco DCNM and SNMP support is not available for this feature.
• This feature is supported only on the Fibre Channel ports on the Cisco MDS 24/10 port SAN Extension
Module.
Enabling FLOGI Scale Optimization and Quiesce Timeout
To enable FLOGI scale optimization and quiesce timeout, perform the following steps:
Step 1
Step 2
Step 3
Step 4
Enter global configuration mode: switch# configure terminal
Enable FLOGI scale optimization: switch(config)# flogi scale enable
Set the FLOGI quiesce timeout value to retain device login information: switch(config)# flogi quiesce timeout milliseconds
For information on the default FLOGI quiesce timeout value, see the
section.
Exit global configuration mode: switch(config)# exit
208
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Managing FLOGI, Name Server, FDMI, and RSCN Databases
Disabling FLOGI Scale Optimization and Quiesce Timeout
Step 5 (Optional) Verify that FLOGI scale optimization is enabled: switch# show flogi internal info | i scale switch# show flogi internal info | i quiesce
Example: Enabling FLOGI Scale Optimization
The following running configuration shows how to enable FLOGI scale optimization and set the quiesce timeout value to 2000 milliseconds: configure terminal flogi scale enable flogi quiesce timeout 2000 exit
Note For more information on FLOGI scale numbers, see the Cisco MDS NX-OS Configuration Limits document.
The following sample outputs from the show flogi internal info | i scale and show flogi internal info | i quiesce commands display details about FLOGI scale optimization: switch# show flogi internal info | i scale
Stats: fs_flogi_scale_enabled: 1 switch# show flogi internal info | i quiesce
Stats: fs_flogi_quiesce_timerval: 2000
Disabling FLOGI Scale Optimization and Quiesce Timeout
To disable FLOGI scale optimization and quiesce timeout, perform the following steps:
Step 1
Step 2
Step 3
Step 4
Step 5
Enter global configuration mode: switch# configure terminal
Disable FLOGI scale optimization: switch(config)# no flogi scale enable
Set the FLOGI quiesce timeout value to 0: switch(config)# flogi quiesce timeout 0
The default quiesce timeout value is 2000 milliseconds.
Exit global configuration mode: switch(config)# exit
(Optional) Verify that FLOGI scale optimization is disabled:
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
209
Managing FLOGI, Name Server, FDMI, and RSCN Databases
Displaying FLOGI Details switch# show flogi internal info | i scale switch# show flogi internal info | i quiesce
Example: Disabling FLOGI Scale Optimization
The following running configuration shows how to disable FLOGI scale optimization and set the quiesce timeout value to 0 milliseconds: configure terminal no flogi scale enable flogi quiesce timeout 0 exit
The following sample outputs from the show flogi internal info | i scale and show flogi internal info | i quiesce commands display details about FLOGI scale optimization: switch# show flogi internal info | i scale
Stats: fs_flogi_scale_enabled: 0 switch# show flogi internal info | i quiesce
Stats: fs_flogi_quiesce_timerval: 0
Displaying FLOGI Details
To view the FLOGI database details, use the show flogi database command. See Examples
Displays Details on the FLOGI Database , on page 210
to
Displays the FLOGI Database by FC ID, on page 211 .
Displays Details on the FLOGI Database switch# show flogi database
---------------------------------------------------------------------------
INTERFACE VSAN FCID PORT NAME NODE NAME
--------------------------------------------------------------------------sup-fc0 2 0xb30100 10:00:00:05:30:00:49:63 20:00:00:05:30:00:49:5e fc9/13 fc9/13 fc9/13
1
1
1
0xb200e2
0xb200e1
0xb200d1
21:00:00:04:cf:27:25:2c
21:00:00:04:cf:4c:18:61
21:00:00:04:cf:4c:18:64
20:00:00:04:cf:27:25:2c
20:00:00:04:cf:4c:18:61
20:00:00:04:cf:4c:18:64 fc9/13 fc9/13
1
1
0xb200ce
0xb200cd
Total number of flogi = 6.
21:00:00:04:cf:4c:16:fb
21:00:00:04:cf:4c:18:f7
20:00:00:04:cf:4c:16:fb
20:00:00:04:cf:4c:18:f7
Displays the FLOGI Database by Interface switch# show flogi database interface fc1/11
INTERFACE VSAN FCID PORT NAME
--------------------------------------------fc1/11 1 0xa002ef 21:00:00:20:37:18:17:d2 fc1/11 1 0xa002e8 21:00:00:20:37:38:a7:c1 fc1/11 fc1/11 fc1/11
1
1
1
0xa002e4
0xa002e2
0xa002e1
21:00:00:20:37:6b:d7:18
21:00:00:20:37:18:d2:45
21:00:00:20:37:39:90:6a
NODE NAME
---------------------
20:00:00:20:37:18:17:d2
20:00:00:20:37:38:a7:c1
20:00:00:20:37:6b:d7:18
20:00:00:20:37:18:d2:45
20:00:00:20:37:39:90:6a
210
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Managing FLOGI, Name Server, FDMI, and RSCN Databases
Name Server fc1/11 fc1/11 fc1/11 fc1/11 fc1/11
1
1
1
1
1
0xa002e0
0xa002dc
0xa002da
0xa002d9
0xa002d6
Total number of flogi = 10.
21:00:00:20:37:36:0b:4d
21:00:00:20:37:5a:5b:27
21:00:00:20:37:18:6f:90
21:00:00:20:37:5b:cf:b9
21:00:00:20:37:46:78:97
20:00:00:20:37:36:0b:4d
20:00:00:20:37:5a:5b:27
20:00:00:20:37:18:6f:90
20:00:00:20:37:5b:cf:b9
0:00:00:20:37:46:78:97
Displays the FLOGI Database by VSAN switch# show flogi database vsan 1
---------------------------------------------------------------------------
INTERFACE VSAN FCID PORT NAME NODE NAME
--------------------------------------------------------------------------fc1/3 fc1/3 fc1/3 fc1/3 fc1/3
1
1
1
1
1
0xef02ef
0xef02e8
0xef02e4
0xef02e2
0xef02e1
22:00:00:20:37:18:17:d2
22:00:00:20:37:38:a7:c1
22:00:00:20:37:6b:d7:18
22:00:00:20:37:18:d2:45
22:00:00:20:37:39:90:6a
20:00:00:20:37:18:17:d2
20:00:00:20:37:38:a7:c1
20:00:00:20:37:6b:d7:18
20:00:00:20:37:18:d2:45
20:00:00:20:37:39:90:6a fc1/3 fc1/3 fc1/3
1
1
1
0xef02e0 22:00:00:20:37:36:0b:4d 20:00:00:20:37:36:0b:4d
0xef02dc 22:00:00:20:37:5a:5b:27 20:00:00:20:37:5a:5b:27
0xef02da 22:00:00:20:37:18:6f:90 20:00:00:20:37:18:6f:90 fc1/3 fc1/3
1
1
0xef02d9
0xef02d6
Total number of flogi = 10.
22:00:00:20:37:5b:cf:b9
22:00:00:20:37:46:78:97
20:00:00:20:37:5b:cf:b9
20:00:00:20:37:46:78:97
Displays the FLOGI Database by FC ID switch# show flogi database fcid 0xef02e2
---------------------------------------------------------------------------
INTERFACE VSAN FCID PORT NAME NODE NAME
--------------------------------------------------------------------------fc1/3 1 0xef02e2 22:00:00:20:37:18:d2:45 20:00:00:20:37:18:d2:45
Total number of flogi = 1.
For more information, see the
Default Company ID List, on page 305
and refer to the “Loop
Monitoring” section in the Cisco MDS 9000 Family Troubleshooting Guide .
Name Server
The name server functionality maintains a database containing the attributes for all hosts and storage devices in each VSAN. Name servers allow a database entry to be modified by a device that originally registered the information.
The proxy feature is useful when you want to modify (update or delete) the contents of a database entry that was previously registered by a different device.
This section includes the following topics:
Bulk Notification Sent from the Name Server
In order to improve the performance of the Fibre Channel protocols on the Cisco MDS 9000 switch, the name server optimizes the remote entry change notifications by sending multiple notifications in one MTS payload.
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
211
Managing FLOGI, Name Server, FDMI, and RSCN Databases
Enabling Name Server Bulk Notification
Nearly 10 other components that receive this MTS notification would have to function on the single bulk notification instead of multiple notifications.
Enabling Name Server Bulk Notification
For NX-OS Release 6.2(1) to 6.2(7), bulk notification is disabled by default. Enabling this feature in one switch has no bearing on the other switches in the same fabric.
Note From NX-OS Release 6.2(9) onwards, bulk notification is enabled by default.
Restrictions
• Whenever the intelligent applications such as the DMM, IOA, and SME are enabled, the bulk notification feature is not supported.
• Any configuration present in the FC-Redirect, conflicts with the bulk notification feature.
Note The above restrictions are applicable only to release 6.2.7.
To enable the name server bulk notification, follow these steps for NX-OS Release 6.2(1) to 6.2(7):
Step 1
Step 2 switch# config t
Enters configuration mode.
switch(config)# fcns bulk-notify switch(config)#
Enables the transmission of multiple name server entry change notification in one Messaging and Transaction Services
(MTS) payload.
Disabling Name Server Bulk Notification
To disable the name server bulk notification, follow these steps for NX-OS Release 6.2(1) to 6.2(7):
Step 1
Step 2 switch# config t
Enters configuration mode.
switch(config)# no fcns bulk-notify switch(config)#
212
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Managing FLOGI, Name Server, FDMI, and RSCN Databases
Disabling Name Server Bulk Notification for NX-OS Release 6.2(9)
Disables the transmission of multiple name server entry change notification in one Messaging and Transaction Services
(MTS) payload.
Disabling Name Server Bulk Notification for NX-OS Release 6.2(9)
To disable the name server bulk notification, follow these steps for NX-OS Release 6.2(9) and later:
Step 1
Step 2 switch# config t
Enters configuration mode.
switch(config)# fcns no-bulk-notify switch(config)#
Disables the transmission of multiple name server entry change notification in one Messaging and Transaction Services
(MTS) payload.
Re-enabling Name Server Bulk Notification
To re-enable once it is disabled already for NX-OS Release 6.2(9) and later, follow these steps:
Step 1
Step 2 switch# config terminal
Enters configuration mode.
switch(config)# no fcns no-bulk-notify switch(config)#
Re-enables the transmission of multiple name server entry change notification in one Messaging and Transaction Services
(MTS) payload.
Name Server Proxy Registration
All name server registration requests are sent from the same port with a parameter that is registered or changed.
If the port that does not have the parameter, then the request is rejected.
This authorization enables WWNs to register specific parameters for another node.
Registering Name Server Proxies
To register the name server proxy, follow these steps:
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
213
Managing FLOGI, Name Server, FDMI, and RSCN Databases
About Rejecting Duplicate pWWN
Step 1
Step 2 switch# config terminal switch(config)#
Enters configuration mode.
switch(config)# fcns proxy-port 21:00:00:e0:8b:00:26:d0 vsan 2
Configures a proxy port for the specified VSAN.
About Rejecting Duplicate pWWN
By FC standard, NX-OS will accept a login on any interface of a pwwn that is already logged in on the same switch, same vsan and same fcdomain. To prevent the same pwwn from logging in the same switch on a different interface, use the port security feature.
By default, any future flogi (with duplicate pwwn) on different switch in the same vsan, will be rejected and previous FLOGI retained, which does not follow FC standards. If you disable this option, any future flogi
(with duplicate pwwn) on different switch in the same VSAN, would be allowed to succeed by deleting previous FCNS entry
Rejecting Duplicate pWWNs
To reject duplicate pWWNs, follow these steps:
Step 1
Step 2
Step 3 switch# configure terminal switch(config)#
Enters configuration mode.
switch(config)# fcns reject-duplicate-pwwn vsan 1
Any future flogi (with duplicate pwwn) on different switch, will be rejected and previous FLOGI retained. (default) switch(config)# no fcns reject-duplicate-pwwn vsan 1
Any future flogi (with duplicate pwwn) on different switch, will be allowed to succeed by deleting earlier FCNS entry.
But you can still see the earlier entry in FLOGI database in the other switch.
Name Server Database Entries
The name server stores name entries for all hosts in the FCNS database. The name server permits an Nx port to register attributes during a PLOGI (to the name server) to obtain attributes of other hosts. These attributes are deregistered when the Nx port logs out either explicitly or implicitly.
In a multiswitch fabric configuration, the name server instances running on each switch shares information in a distributed database. One instance of the name server process runs on each switch.
214
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Managing FLOGI, Name Server, FDMI, and RSCN Databases
Optimizing Name Server Database Sync
Optimizing Name Server Database Sync
If an end device doesn't register FC4 feature with Name Server database, VHBA (also called scsi-target) component would perform PRLI to the end device to discover FC4 feature and register with Name Server on behalf of end device. This discovery from VHBA was performed both for locally connected devices as well as remotely connected devices. This discovery was unnecessary for remotely connected devices because, Name Server would get FC4 feature of remotely connected devices through regular Name Server sync protocol. So, the default behavior of VHBA component has been modified to discover only locally connected devices. To modify this behavior, follow these steps:
Step 1
Step 2 switch(config)# scsi-target discovery
Enables a switch to discover fc4-feature for remote devices also. But this would not be the default behavior if the users reload or switchover the switch.
switch(config)# scsi-target discovery local-only
Switches back to the default behavior.
Verifying the Number of Name Server Database Entries
To Verify the number of name server database entries, follow these steps:
Step 1
Step 2 switch# show fcns internal info global
Displays the number of device entries in the name server database.
switch# show fcns internal info
Displays the number of devices in the name server database at the end of the output.
Displaying Name Server Database Entries
Use the show fcns command to display the name server database and statistical information for a specified
VSAN or for all VSANs (see Examples
Displays the Name Server Database, on page 215
to
Name Server Statistics, on page 217
).
Displays the Name Server Database switch# show fcns database
--------------------------------------------------------------------------
FCID TYPE PWWN (VENDOR) FC4-TYPE:FEATURE
--------------------------------------------------------------------------
0x010000 N 50:06:0b:00:00:10:a7:80 scsi-fcp fc-gs
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
215
Managing FLOGI, Name Server, FDMI, and RSCN Databases
Displaying Name Server Database Entries
0x010001
0x010002
0x010100
0x020000
0x020100
0x020200
N
N
N
N
N
N
10:00:00:05:30:00:24:63 (Cisco)
50:06:04:82:c3:a0:98:52 (Company 1)
21:00:00:e0:8b:02:99:36 (Company A)
21:00:00:e0:8b:08:4b:20 (Company A)
10:00:00:05:30:00:24:23 (Cisco)
21:01:00:e0:8b:22:99:36 (Company A) ipfc scsi-fcp 250 scsi-fcp ipfc scsi-fcp
Displays the Name Server Database for the Specified VSAN switch# show fcns database vsan 1
VSAN 1:
--------------------------------------------------------------------------
FCID TYPE PWWN (VENDOR) FC4-TYPE:FEATURE
--------------------------------------------------------------------------
0x030001 N 10:00:00:05:30:00:25:a3 (Cisco) ipfc
0x030101 NL 10:00:00:00:77:99:60:2c (Interphase)
0x030200
0xec0001
N
NL
10:00:00:49:c9:28:c7:01
21:00:00:20:37:a6:be:14 (Seagate)
Total number of entries = 4 scsi-fcp
Displays the Name Server Database Details switch# show fcns database detail
------------------------
VSAN:1 FCID:0x030001
-----------------------port-wwn (vendor) :10:00:00:05:30:00:25:a3 (Cisco) node-wwn class
:20:00:00:05:30:00:25:9e
:2,3 node-ip-addr ipa
:0.0.0.0
:ff ff ff ff ff ff ff ff fc4-types:fc4_features:ipfc symbolic-port-name symbolic-node-name
:
: port-type port-ip-addr fabric-port-wwn
:N
:0.0.0.0
:00:00:00:00:00:00:00:00 hard-addr :0x000000
------------------------
VSAN:1 FCID:0xec0200
-----------------------port-wwn (vendor) :10:00:00:5a:c9:28:c7:01 node-wwn class
:10:00:00:5a:c9:28:c7:01
:3 node-ip-addr ipa fc4-types:fc4_features:
:0.0.0.0
:ff ff ff ff ff ff ff ff symbolic-port-name symbolic-node-name
:
: port-type port-ip-addr fabric-port-wwn
:N
:0.0.0.0
:22:0a:00:05:30:00:26:1e hard-addr :0x000000
Total number of entries = 2
216
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Managing FLOGI, Name Server, FDMI, and RSCN Databases
FDMI
Displays the Name Server Statistics switch# show fcns statistics registration requests received = 27 deregistration requests received = 0 queries received = 57 queries sent = 10 reject responses sent = 14
RSCNs received = 0
RSCNs sent = 0
FDMI
Cisco MDS 9000 Family switches provide support for the Fabric-Device Management Interface (FDMI) functionality, as described in the FC-GS-4 standard. FDMI enables management of devices such as Fibre
Channel host bus adapters (HBAs) through in-band communications. This addition complements the existing
Fibre Channel name server and management server functions.
Using the FDMI functionality, the Cisco NX-OS software can extract the following management information about attached HBAs and host operating systems without installing proprietary host agents:
• Manufacturer, model, and serial number
• Node name and node symbolic name
• Hardware, driver, and firmware versions
• Host operating system (OS) name and version number
All FDMI entries are stored in persistent storage and are retrieved when the FDMI process is started.
Displaying FDMI
Use the show fdmi command to display the FDMI database information (see Examples
Management Servers, on page 217
to
Displays Details for the Specified HBA Entry, on page 219
).
Displays All HBA Management Servers switch# show fdmi database
Registered HBA List for VSAN 1
10:00:00:00:c9:32:8d:77
21:01:00:e0:8b:2a:f6:54 switch# show fdmi database detail
Registered HBA List for VSAN 1
-------------------------------
HBA-ID: 10:00:00:00:c9:32:8d:77
-------------------------------
Node Name
Manufacturer
Serial Num
:20:00:00:00:c9:32:8d:77
:Emulex Corporation
:0000c9328d77
Model :LP9002
Model Description:Emulex LightPulse LP9002 2 Gigabit PCI Fibre Channel Adapter
Hardware Ver :2002606D
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
217
Displaying FDMI
Managing FLOGI, Name Server, FDMI, and RSCN Databases
Driver Ver
ROM Ver
:SLI-2 SW_DATE:Feb 27 2003, v5-2.20a12
:3.11A0
Firmware Ver
OS Name/Ver
:3.90A7
:Window 2000
CT Payload Len :1300000
Port-id: 10:00:00:00:c9:32:8d:77
-------------------------------
HBA-ID: 21:01:00:e0:8b:2a:f6:54
-------------------------------
Node Name :20:01:00:e0:8b:2a:f6:54
Manufacturer
Serial Num
:QLogic Corporation
:\74262
Model :QLA2342
Model Description:QLogic QLA2342 PCI Fibre Channel Adapter
Hardware Ver :FC5010409-10
Driver Ver
ROM Ver
:8.2.3.10 Beta 2 Test 1 DBG (W2K VI)
:1.24
Firmware Ver
OS Name/Ver
:03.02.13.
:500
CT Payload Len :2040
Port-id: 21:01:00:e0:8b:2a:f6:54
Displays HBA Details for a Specified VSAN switch# show fdmi database detail vsan 1
Registered HBA List for VSAN 1
-------------------------------
HBA-ID: 10:00:00:00:c9:32:8d:77
-------------------------------
Node Name :20:00:00:00:c9:32:8d:77
Manufacturer :Emulex Corporation
Serial Num
Model
:0000c9328d77
:LP9002
Model Description:Emulex LightPulse LP9002 2 Gigabit PCI Fibre Channel Adapter
Hardware Ver :2002606D
Driver Ver :SLI-2 SW_DATE:Feb 27 2003, v5-2.20a12
ROM Ver
Firmware Ver
:3.11A0
:3.90A7
OS Name/Ver :Window 2000
CT Payload Len :1300000
Port-id: 10:00:00:00:c9:32:8d:77
-------------------------------
HBA-ID: 21:01:00:e0:8b:2a:f6:54
-------------------------------
Node Name :20:01:00:e0:8b:2a:f6:54
Manufacturer :QLogic Corporation
Serial Num
Model
:\74262
:QLA2342
Model Description:QLogic QLA2342 PCI Fibre Channel Adapter
Hardware Ver :FC5010409-10
Driver Ver :8.2.3.10 Beta 2 Test 1 DBG (W2K VI)
ROM Ver
Firmware Ver
:1.24
:03.02.13.
OS Name/Ver :500
CT Payload Len :2040
Port-id: 21:01:00:e0:8b:2a:f6:54
218
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Managing FLOGI, Name Server, FDMI, and RSCN Databases
VMID
Displays Details for the Specified HBA Entry switch# show fdmi database detail hba-id 21:01:00:e0:8b:2a:f6:54 vsan 1
Node Name :20:01:00:e0:8b:2a:f6:54
Manufacturer
Serial Num
:QLogic Corporation
:\74262
Model :QLA2342
Model Description:QLogic QLA2342 PCI Fibre Channel Adapter
Hardware Ver :FC5010409-10
Driver Ver
ROM Ver
:8.2.3.10 Beta 2 Test 1 DBG (W2K VI)
:1.24
Firmware Ver
OS Name/Ver
:03.02.13.
:500
CT Payload Len :2040
Port-id: 21:01:00:e0:8b:2a:f6:54
VMID
Note The VMID feature is currently in preview (beta) status for use in non-production environment only. This preview (beta) status and restriction will change to regular production status in an upcoming release.
The switch-based Virtual Machine Identifier (VMID) feature allows identification of traffic sources at an individual virtual machine (VM) level by the SAN fabric infrastructure.
VMID on the MDS switch provides a range of identifiers to a host hypervisor. These identifiers can then be assigned to local VMs by the hypervisor. Supplemental information about the VM assigned to an identifier is reported back to the switch. The identifiers are then inserted into the CS_CTL field of traffic from the VMs by the hypervisor, allowing identification of the traffic source by the SAN fabric.
The VMID feature uses the following IDs:
• Virtual Entity (VE): Refers to any virtual device.
• Virtual Entities Manager (VEM): Refers to a hypervisor.
• Virtual Entity Identifier (VE ID): Refers to the different types of identifiers assigned to VEs. There are four types of VE IDs:
• Local VE ID: Local VE ID is used to uniquely identify a VE within a VEM N_Port. Local VE IDs change when virtual machines come up, go down, or go through migration between VEMs.
• Fabric VE ID: Fabric VE ID is used to uniquely identify a VE within a fabric. It is a combination of the VEM N_Port FCID and the Local VE ID.
• Global VE ID: Global VE ID is used to uniquely identify a VE and is a 16-byte Universally Unique
Identifier (UUID). The Global VE ID is assigned by a service outside the SAN fabric such as a VM management platform. Once a global VE ID is assigned, it does not expire.
• VEM ID: VEM ID is used to uniquely identify a VEM and is a 16-byte UUID. The VEM ID is assigned by a service outside the SAN fabric such as a VM management platform.
• Fabric ports on a VEM comprise of the following N_Ports:
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
219
VMID
Managing FLOGI, Name Server, FDMI, and RSCN Databases
• Physical Network Port (PN_Port): A physical network port of a hypervisor host bus adapter (HBA).
• Virtual Network Port (VN_Port): An optional virtual network port that can be shared by a set of
VEs. A PN_Port can have multiple VN_Ports. Each VN_Port is allocated a unique FCID.
• Physical Fabric Port (PF_Port): A physical fabric port of a switch.
When an HBA Port Comes Up
After an HBA driver has logged a physical or virtual HBA port into the fabric, the driver may request Local
VE IDs from the fabric through the port. The Virtual Machine Identification Server (VMIS) on the locally attached switch provides the range of Local VE IDs (up to 255) in the response. The driver then assigns the identifiers to the port FCID.
When a VM Initially Accesses a Disk
Outside of a fabric, a VM is identified by a Global VE ID. Within a fabric, a VM is identified by a Fabric VE
ID. When a VM initially accesses a virtual disk, the hypervisor starts accessing the corresponding physical disk through an HBA port. For each path to the physical disk an unused Local VE ID from the pool for the
FCID is assigned. The FCID and Local VE ID are combined to create a unique Fabric VE ID by the HBA driver. The HBA driver then notifies the locally attached VMIS about the assigned VE ID to Global VE ID mapping. This mapping is done for each VM path to the fabric through the hypervisor and allows all VM traffic to be identified by SAN tools by path, such as Cisco MDS SAN Analytics.
When a VM Goes Down or Moves Within a Fabric
The difference between a Global VE ID and Local VE ID is seen when a VM migrates between VEMs. When a VM is deinstantiated or migrated between VEMs, the Local VE ID is returned to the pool by the HBA driver, but does not notify the switch VMIS. The switch will time out the Local VE ID or VM mapping after 1 to 4 hours of no traffic. If a VM reinstantiates on the same VEM, it may get a different Local VE ID from the pool of the same FCID because the previously assigned Local VE ID may have been allocated to another VM when this VM was down. When a VM migrates to a different VEM, the VM will likely utilize a different FCID and likely be assigned a different Local VE ID from the FCID's pool. Thus, when a VM reboots or migrates between VEMs, the Global VE ID remains constant but Local VE ID may change.
Figure 53: VMID Components, on page 221
show the components of VMID:
220
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Managing FLOGI, Name Server, FDMI, and RSCN Databases
Figure 53: VMID Components
Guidelines and Limitations for VMID
Figure 54: VE ID Life Cycle, on page 221
shows how VE ID changes during a VM life cycle:
Figure 54: VE ID Life Cycle
Guidelines and Limitations for VMID
• The VMID feature is not supported on Cisco N-Port Virtualizer (Cisco NPV) switches.
• There is no mechanism in the VMID protocol for the VMIS to notify the attached hypervisor HBA driver clients of a new VE ID range. For clients to detect a new range, they must query the VMIS again. To force the clients to query again after a range modification, the user must manually log the FCIDs out and back into the fabric. Consequently, local clients will continue to tag the VM traffic with the previous
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
221
Managing FLOGI, Name Server, FDMI, and RSCN Databases
Configuring the VMID Server range until this occurs. This restriction applies when enabling and disabling VMID, and changing the
VE ID range of a VSAN.
• The Extended Receiver Ready (ER_RDY) feature uses CSCTL 1 to 15. The VMID feature uses CSCTL
16 to 255. If the VMID database has any interfaces that are configured in the VMIS range 1 to 15 and if you are upgrading to Cisco MDS NX-OS Release 9.2(1) or later releases, then you will prompted to change the range between 16 to 255 and flap the interfaces before upgrading.
• The VMID feature is not supported in any VSAN which has interoperability enabled. For more information about interoperability modes, see the Cisco MDS 9000 Series Switch-to-Switch Interoperability
Configuration Guide .
Configuring the VMID Server
Enabling the VMID Server
To enable the VMID Server feature, perform these steps:
Step 1
Step 2
Enter global configuration mode: switch# configure terminal
Enable the VMID Server feature: switch(config)# feature vmis
Disabling the VMID Server
To disable the VMID Server feature, perform these steps:
Step 1
Step 2
Enter global configuration mode: switch# configure terminal
Disable the VMID Server feature: switch(config)# no feature vmis
Configuring a VMID Range
The VMID range is used to limit the Local VE IDs an HBA driver will use. By restricting the Local VE ID range to use a subset of bits in the CS_CTL field it can be partitioned and shared with future Fibre Channel features.
To configure a VMID range, perform these steps:
Step 1 Enter global configuration mode:
222
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Managing FLOGI, Name Server, FDMI, and RSCN Databases
Examples: Configuring the VMID Server
Step 2 switch# configure terminal
Configure VE ID range for use within a VSAN: switch(config)# vmis range range vsan id
Examples: Configuring the VMID Server
This example shows how to enable the VMID Server feature: switch# configure terminal switch(config)# feature vmis
This example shows how to disable the VMID Server feature: switch# configure terminal switch(config)# no feature vmis
This example shows how to configure multiple Local VE ID ranges for use by hypervisor HBA drivers in a
VSAN: switch# configure terminal switch(config)# vmis range 3-45,51-70 vsan 1
Verifying a VMID Configuration
This example shows the FCIDs that are capable of using the VMID Server feature. The letter M under the
FLAGS field indicates that the corresponding FCID is capable of using the VMID Server feature.
switch# show flogi database details
--------------------------------------------------------------------------------------------
INTERFACE VSAN FCID PORT NAME NODE NAME FLAGS
-------------------------------------------------------------------------------------------fc1/7 1 0xef0000 20:07:8c:60:4f:10:0f:e0 20:01:8c:60:4f:10:0f:e1 P fc1/7 1 0xef0001 20:19:8c:60:4f:19:bf:25 21:00:00:20:38:de:c3:9f VP M
Total number of flogi = 2.
This example shows all the entries in a VMIS database. This is the database of all IDs in the SAN fabric.
Locally connected IDs show the connecting interface; remotely connected IDs show the interface name as
"--" in the output.
switch# show vmis database
Total 17 entries
----------------------------------------------------------------------------------
INTERFACE VSAN FCID LOCAL VEID GLOBAL VEID
---------------------------------------------------------------------------------fc1/7 1 0xef000a 0x01 9a07686b-0405-0607-0809-0a0b0c0d0e0f fc1/7 fc1/7
1
1
0xef000a 0x02
0xef000a 0x03
66fb6a4e-0405-0607-0809-0a0b0c0d0e0f
325de425-0405-0607-0809-0a0b0c0d0e0f
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
223
Managing FLOGI, Name Server, FDMI, and RSCN Databases
Verifying a VMID Configuration
--
--
--
--
-fc1/7 fc1/7 fc1/7 fc1/7 fc1/7 fc1/7 fc1/7 fc1/7 fc1/7
1
1
1
1
1
1
1
1
1
10
10
10
10
10
0xef000a 0x04
0xef000a 0x05
0xef000a 0x32
0xef000b 0x01
0xef000b 0x02
0xef000b 0x03
0xef000b 0x04
0xef000b 0x05
0xef000b 0x1e
0x4c0020 0x1e
0x4c0020 0x1f
0x4c0020 0x20
0x4c0020 0x21
0x4c0020 0x22
0d509b51-0405-0607-0809-0a0b0c0d0e0f b7d71b43-0405-0607-0809-0a0b0c0d0e0f
1b231602-0405-0607-0809-0a0b0c0d0e0f e8e9161f-0405-0607-0809-0a0b0c0d0e0f e7cd9011-0405-0607-0809-0a0b0c0d0e0f
8d43ef66-0405-0607-0809-0a0b0c0d0e0f
760f0e14-0405-0607-0809-0a0b0c0d0e0f
5a255233-0405-0607-0809-0a0b0c0d0e0f
1b231602-0405-0607-0809-0a0b0c0d0e0f ba581b3d-0405-0607-0809-0a0b0c0d0e0f abd77e50-0405-0607-0809-0a0b0c0d0e0f f241b12e-0405-0607-0809-0a0b0c0d0e0f fb1eb741-0405-0607-0809-0a0b0c0d0e0f e3a9e279-0405-0607-0809-0a0b0c0d0e0f
This example shows a VMIS database entries of a specified local VSAN domain: switch# show vmis database local vsan 1
Total 12 entries
----------------------------------------------------------------------------------
INTERFACE VSAN FCID LOCAL VEID GLOBAL VEID
---------------------------------------------------------------------------------fc1/7 fc1/7
1
1
0xef000a 0x01
0xef000a 0x02
9a07686b-0405-0607-0809-0a0b0c0d0e0f
66fb6a4e-0405-0607-0809-0a0b0c0d0e0f fc1/7 fc1/7 fc1/7 fc1/7 fc1/7
1
1
1
1
1
0xef000a
0xef000a
0xef000a
0xef000a
0xef000b
0x03
0x04
0x05
0x32
0x01
325de425-0405-0607-0809-0a0b0c0d0e0f
0d509b51-0405-0607-0809-0a0b0c0d0e0f b7d71b43-0405-0607-0809-0a0b0c0d0e0f
1b231602-0405-0607-0809-0a0b0c0d0e0f e8e9161f-0405-0607-0809-0a0b0c0d0e0f fc1/7 fc1/7 fc1/7 fc1/7 fc1/7
1
1
1
1
1
0xef000b 0x02
0xef000b 0x03
0xef000b 0x04
0xef000b 0x05
0xef000b 0x1e e7cd9011-0405-0607-0809-0a0b0c0d0e0f
8d43ef66-0405-0607-0809-0a0b0c0d0e0f
760f0e14-0405-0607-0809-0a0b0c0d0e0f
5a255233-0405-0607-0809-0a0b0c0d0e0f
1b231602-0405-0607-0809-0a0b0c0d0e0f
This example shows the entries in a VSAN filtered by the hosting domain: switch# show vmis database domain 0xef vsan 1
Total 12 entries
----------------------------------------------------------------------------------
INTERFACE VSAN FCID LOCAL VEID GLOBAL VEID
---------------------------------------------------------------------------------fc1/7 1 0xef000a 0x01 9a07686b-0405-0607-0809-0a0b0c0d0e0f fc1/7 1 0xef000a 0x02 66fb6a4e-0405-0607-0809-0a0b0c0d0e0f fc1/7 fc1/7
1
1
0xef000a 0x03
0xef000a 0x04
325de425-0405-0607-0809-0a0b0c0d0e0f
0d509b51-0405-0607-0809-0a0b0c0d0e0f fc1/7 fc1/7 fc1/7 fc1/7 fc1/7 fc1/7 fc1/7 fc1/7
1
1
1
1
1
1
1
1
0xef000a 0x05
0xef000a 0x32
0xef000b
0xef000b
0xef000b
0xef000b
0xef000b
0xef000b
0x01
0x02
0x03
0x04
0x05
0x1e b7d71b43-0405-0607-0809-0a0b0c0d0e0f
1b231602-0405-0607-0809-0a0b0c0d0e0f e8e9161f-0405-0607-0809-0a0b0c0d0e0f e7cd9011-0405-0607-0809-0a0b0c0d0e0f
8d43ef66-0405-0607-0809-0a0b0c0d0e0f
760f0e14-0405-0607-0809-0a0b0c0d0e0f
5a255233-0405-0607-0809-0a0b0c0d0e0f
1b231602-0405-0607-0809-0a0b0c0d0e0f
This example shows the entries in a VSAN filtered by an interface: switch# show vmis database interface fc1/7 vsan 1
Total 12 entries
----------------------------------------------------------------------------------
224
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Managing FLOGI, Name Server, FDMI, and RSCN Databases
Verifying a VMID Configuration
INTERFACE VSAN FCID LOCAL VEID GLOBAL VEID
---------------------------------------------------------------------------------fc1/7 fc1/7
1
1
0xef000a
0xef000a
0x01
0x02
9a07686b-0405-0607-0809-0a0b0c0d0e0f
66fb6a4e-0405-0607-0809-0a0b0c0d0e0f fc1/7 fc1/7 fc1/7 fc1/7 fc1/7
1
1
1
1
1
0xef000a
0xef000a
0xef000a
0xef000a
0xef000b
0x03
0x04
0x05
0x32
0x01
325de425-0405-0607-0809-0a0b0c0d0e0f
0d509b51-0405-0607-0809-0a0b0c0d0e0f b7d71b43-0405-0607-0809-0a0b0c0d0e0f
1b231602-0405-0607-0809-0a0b0c0d0e0f e8e9161f-0405-0607-0809-0a0b0c0d0e0f fc1/7 fc1/7 fc1/7 fc1/7 fc1/7
1
1
1
1
1
0xef000b 0x02
0xef000b 0x03
0xef000b 0x04
0xef000b 0x05
0xef000b 0x1e e7cd9011-0405-0607-0809-0a0b0c0d0e0f
8d43ef66-0405-0607-0809-0a0b0c0d0e0f
760f0e14-0405-0607-0809-0a0b0c0d0e0f
5a255233-0405-0607-0809-0a0b0c0d0e0f
1b231602-0405-0607-0809-0a0b0c0d0e0f
This example shows the entries in a VSAN: switch# show vmis database vsan 10
Total 5 entries
----------------------------------------------------------------------------------
INTERFACE VSAN FCID LOCAL VEID GLOBAL VEID
----------------------------------------------------------------------------------
--
--
10
10
0x4c0020 0x1e
0x4c0020 0x1f ba581b3d-0405-0607-0809-0a0b0c0d0e0f abd77e50-0405-0607-0809-0a0b0c0d0e0f
--
--
--
10
10
10
0x4c0020 0x20
0x4c0020 0x21
0x4c0020 0x22 f241b12e-0405-0607-0809-0a0b0c0d0e0f fb1eb741-0405-0607-0809-0a0b0c0d0e0f e3a9e279-0405-0607-0809-0a0b0c0d0e0f
This example shows the entries filtered by FCIDs. This example is filtered by a remote hypervisor N_Port
FCID.
--
--
--
-switch# show vmis database fcid 0x4c0020 vsan 10
Total 5 entries
----------------------------------------------------------------------------------
INTERFACE VSAN FCID LOCAL VEID GLOBAL VEID
----------------------------------------------------------------------------------
-10 0x4c0020 0x1e ba581b3d-0405-0607-0809-0a0b0c0d0e0f
10
10
10
10
0x4c0020 0x1f
0x4c0020 0x20
0x4c0020
0x4c0020
0x21
0x22 abd77e50-0405-0607-0809-0a0b0c0d0e0f f241b12e-0405-0607-0809-0a0b0c0d0e0f fb1eb741-0405-0607-0809-0a0b0c0d0e0f e3a9e279-0405-0607-0809-0a0b0c0d0e0f
This example shows the VMIS entries filtered by Global VM ID and VSAN: switch# show vmis database global-vmid e8e9161f-0405-0607-0809-0a0b0c0d0e0f vsan 1
Total 1 entries
----------------------------------------------------------------------------------
INTERFACE VSAN FCID LOCAL VEID GLOBAL VEID
---------------------------------------------------------------------------------fc1/7 1 0xef000b 0x01 e8e9161f-0405-0607-0809-0a0b0c0d0e0f
This example shows the VEM IDs registered in a VSAN: switch# show vmis database vem vsan 1
Total 2 entries
-----------------------------------------------------------------------------
INTERFACE VSAN FCID VEM ID
-----------------------------------------------------------------------------
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
225
Managing FLOGI, Name Server, FDMI, and RSCN Databases
RSCN fc1/7 fc1/7
1
1
0xef000a 11223344-5566-7788-99aa-bbccddeeffaa
0xef000b 00010203-0405-0607-0809-0a0b0cef000b
This example shows VM entries that have migrated between VEMs:
The output shows two entries correspond to a VM before and after a VM has migrated between VEMs. The
IDs associated with the VM before migration are not deleted immediately. These IDs will be deleted in the
VMIS database after the switch IO timer expires. Until the IO timer expires, you will see two entries of the same VM in the VMIS database.
switch# show vmis database vmotion vsan 1
Total 2 entries
----------------------------------------------------------------------------------
INTERFACE VSAN FCID LOCAL VEID GLOBAL VEID
---------------------------------------------------------------------------------fc1/7 1 0xef000b 0x1e 1b231602-0405-0607-0809-0a0b0c0d0e0f fc1/7 1 0xef000a 0x32 1b231602-0405-0607-0809-0a0b0c0d0e0f
This example shows a Local VE ID range that is configured for each VSAN: switch# show vmis range
VSAN VEID Range
--------------------
1 1-255
10
20
30
1-255
1-255
1-255
This example shows statistics of a local switch's VMIS exchanges with locally attached hypervisor HBA driver clients (host side) and with other VMIS agents on other switches in the fabric (switch side) by VSAN: switch# show vmis statistics
VSAN : 1
-----Host Side----qfpa/qfpa_rsp/qfpa_rjt : 1/1/0 uvem/uvem_rsp/uvem_rjt : 1/1/0 ggvid/ggvid_rsp/ggvid_rjt : 0/0/0 gfvid/gfvid_rsp/gfvid_rjt : 0/0/0 gvemid/gvemid_rsp/gvemid_rjt : 0/0/0 gvem/gvem_rsp/gvem_rjt : 0/0/0
-----Switch Side----gvemd_tx/gvemd_rsp_tx/gvemd_rjt_tx : 0/0/0 gvemd_rx/gvemd_rsp_rx/gvemd_rjt_rx : 0/0/0 uvemd_tx/uvemd_rsp_tx/uvemd_rjt_tx : 0/0/0 uvemd_rx/uvemd_rsp_rx/uvemd_rjt_rx : 0/0/0
RSCN
The Registered State Change Notification (RSCN) is a Fibre Channel service that informs hosts about changes in the fabric. Hosts can receive this information by registering with the fabric controller (through SCR). These notifications provide a timely indication of one or more of the following events:
• Disks joining or leaving the fabric.
226
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Managing FLOGI, Name Server, FDMI, and RSCN Databases
About RSCN Information
• A name server registration change.
• A new zone enforcement.
• IP address change.
• Any other similar event that affects the operation of the host.
This section includes the following topics:
About RSCN Information
Apart from sending these events to registered hosts, a switch RSCN (SW-RSCN) is sent to all reachable switches in the fabric.
Note The switch sends an RSCN to notify registered nodes that a change has occurred. It is up to the nodes to query the name server again to obtain the new information. The details of the changed information are not delivered by the switch in the RSCN sent to the nodes.
Displaying RSCN Information
Use the show rscn command to display RSCN information (see Examples
and
Displays RSCN Counter Information, on page 227 ).
Displays Register Device Information switch# show rscn scr-table vsan 1
SCR table for VSAN: 1
---------------------------------------------
FC-ID REGISTERED FOR
---------------------------------------------
0x1b0300 fabric detected rscns
Total number of entries = 1
Note The SCR table is not configurable. It is populated when hosts send SCR frames with RSCN information. If hosts do not receive RSCN information, then the show rscn scr-table command will not return entries.
Displays RSCN Counter Information switch(config)# show rscn statistics vsan 106
Statistics for VSAN: 106
-------------------------
Number of SCR received
Number of SCR ACC sent
= 0
= 0
Number of SCR RJT sent
Number of RSCN received
Number of RSCN sent
Number of RSCN ACC received
= 0
= 0
= 0
= 0
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
227
Managing FLOGI, Name Server, FDMI, and RSCN Databases multi-pid Option
Number of RSCN ACC sent
Number of RSCN RJT received
Number of RSCN RJT sent
Number of SW-RSCN received
Number of SW-RSCN sent
= 0
= 0
= 0
= 0
= 0
Number of SW-RSCN ACC received = 0
Number of SW-RSCN ACC sent = 0
Number of SW-RSCN RJT received = 0
Number of SW-RSCN RJT sent = 0
Number of CSWR received = 3137
Number of CSWR sent
Number of CSWR ACC received
= 0
= 0
Number of CSWR ACC sent
Number of CSWR RJT received
Number of CSWR RJT sent
Number of CSWR RJT not sent
= 3137
= 0
= 0
= 0
multi-pid Option
If the RSCN multi-pid option is enabled, then RSCNs generated to the registered Nx ports may contain more than one affected port IDs. In this case, zoning rules are applied before putting the multiple affected port IDs together in a single RSCN. By enabling this option, you can reduce the number of RSCNs. For example:
Suppose you have two disks (D1, D2) and a host (H) connected to switch 1. Host H is registered to receive
RSCNs. D1, D2 and H belong to the same zone. If disks D1 and D2 are online at the same time, then one of the following applies:
• The multi-pid option is disabled on switch 1: two RSCNs are generated to host H—one for the disk D1 and another for disk D2.
• The multi-pid option is enabled on switch 1: a single RSCN is generated to host H, and the RSCN payload lists the affected port IDs (in this case, both D1 and D2).
Note Some Nx ports may not understand multi-pid RSCN payloads. If not, disable the RSCN multi-pid option.
Configuring the multi-pid Option
To configure the multi-pid option, follow these steps:
Step 1
Step 2 switch# config terminal switch(config)#
Enters configuration mode.
switch(config)# rscn multi-pid vsan 105
Sends RSCNs in a multi-pid format for VSAN 105.
228
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Managing FLOGI, Name Server, FDMI, and RSCN Databases
Suppressing Domain Format SW-RSCNs
Suppressing Domain Format SW-RSCNs
A domain format SW-RSCN is sent whenever the local switch name or the local switch management IP address changes. This SW-RSCN is sent to all other domains and switches over the ISLs. The remote switches can issue GMAL and GIELN commands to the switch that initiated the domain format SW-RSCN to determine what changed. Domain format SW-RSCNs can cause problems with some non-Cisco MDS switches (refer to the ).
To suppress the transmission of these SW RSCNs over an ISL, follow these steps:
Step 1
Step 2 switch# config terminal switch(config)#
Enters configuration mode.
switch(config)# rscn suppress domain-swrscn vsan 105
Suppresses transmission of domain format SW-RSCNs for VSAN 105.
Note You cannot suppress transmission of port address or area address format RSCNs.
Coalesced SW-RSCN
In order to improve the performance of the Fibre Channel protocols on the Cisco MDS 9000 switch, SW-RSCNs are delayed, collected and sent as a single coalesced SW-RSCN to all the switches in the fabric in a single
Fibre Channel exchange.
Enabling Coalesced SW-RSCNs
Restrictions
• All the switches in the fabric should be running Cisco MDS 6.2(7) and above.
• This feature does not have interoperability with non-Cisco MDS switches.
To enable the coalesced SW-RSCNs, follow these step:
Step 1
Step 2
Step 3 switch# config terminal
Enters configuration mode.
switch(config)# rscn coalesce swrscn vsan 1 switch(config)#
Enables coalescing of Switch Registered State Change Notification (SWRSCN) in VSAN 1. The default delay is 500 milliseconds.
switch(config)# rscn coalesce swrscn vsan 1 delay 800 switch(config)#
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
229
Managing FLOGI, Name Server, FDMI, and RSCN Databases
Disabling Coalesced SW-RSCNs
Enables coalescing of Switch Registered State Change Notification (SWRSCN) in VSAN 1. Delays the SW-RSCNs maximum by 800 milliseconds.
Note All the switches running 6.2(7) and above are capable of processing coalesced SW-RSCN by default, but they are capable of sending coalesced SW-RSCN only after enabling through CLI.
Disabling Coalesced SW-RSCNs
To disable the coalesced SW-RSCNs, follow these steps:
Step 1
Step 2 switch# config terminal
Enters configuration mode.
switch(config)# no rscn coalesce swrscn vsan 1 switch(config)#
Disables coalescing of Switch Registered State Change Notification (SWRSCN) in VSAN 1.
Clearing RSCN Statistics
You can clear the counters and later view the counters for a different set of events. For example, you can keep track of how many RSCNs or SW-RSCNs are generated on a particular event (such as ONLINE or OFFLINE events). You can use these statistics to monitor responses for each event in the VSAN.
Use the clear rscn statistics command to clear the RSCN statistics for the specified VSAN.
switch# clear rscn statistics vsan 1
After clearing the RSCN statistics, you can view the cleared counters by issuing the show rscn command.
switch# show rscn statistics vsan 1
Statistics for VSAN: 1
-------------------------
Number of SCR received
Number of SCR ACC sent
Number of SCR RJT sent
Number of RSCN received
Number of RSCN sent
Number of RSCN ACC received
Number of RSCN ACC sent
= 0
= 0
= 0
= 0
= 0
= 0
= 0
Number of RSCN RJT received
Number of RSCN RJT sent
Number of SW-RSCN received
= 0
= 0
= 0
Number of SW-RSCN sent = 0
Number of SW-RSCN ACC received = 0
Number of SW-RSCN ACC sent = 0
Number of SW-RSCN RJT received = 0
Number of SW-RSCN RJT sent = 0
Number of CSWR received
Number of CSWR sent
= 0
= 0
230
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Managing FLOGI, Name Server, FDMI, and RSCN Databases
RSCN Timer Configuration Distribution Using CFS
Number of CSWR ACC received
Number of CSWR ACC sent
Number of CSWR RJT received
Number of CSWR RJT sent
Number of CSWR RJT not sent
= 0
= 0
= 0
= 0
= 0
RSCN Timer Configuration Distribution Using CFS
Because the timeout value for each switch is configured manually, a misconfiguration occurs when different switches time out at different times. This means different N ports in a network can receive RSCNs at different times. Cisco Fabric Services (CFS) alleviates this situation by automatically distributing configuration information to all switches in a fabric. This also reduces the number of SW-RSCNs.
RSCN supports two modes, distributed and nondistributed. In distributed mode, RSCN uses CFS to distribute configuration to all switches in the fabric. In nondistributed mode, only the configuration commands on the local switch are affected.
Note All configuration commands are not distributed. Only the rscn event-tov tov vsan vsan command is distributed.
The RSCN timer is registered with CFS during initialization and switchover. For high availability, if the
RSCN timer distribution crashes and restarts or a switchover occurs, it resumes normal functionality from the state prior to the crash or switchover.
Note Before performing a downgrade, make sure that you revert the RCSN timer value in your network to the default value. Failure to do so will disable the links across your VSANs and other devices.
Compatibility across various Cisco MDS NX-OS releases during an upgrade or downgrade is supported by conf-check provided by CFS. If you attempt to downgrade from Cisco MDS SAN-OS Release 3.0, you are prompted with a conf-check warning. You are required to disable RSCN timer distribution support before you downgrade.
By default, the RSCN timer distribution capability is disabled and is therefore compatible when upgrading from any Cisco MDS SAN-OS release earlier than Release 3.0.
Configuring the RSCN Timer
RSCN maintains a per-VSAN event list queue, where the RSCN events are queued as they are generated.
When the first RSCN event is queued, a per VSAN timer starts. Upon time-out, all the events are dequeued and coalesced RSCNs are sent to registered users. The default timer values minimize the number of coalesced
RSCNs sent to registered users. Some deployments require smaller event timer values to track changes in the fabric.
Note The RSCN timer value must be the same on all switches in the VSAN. See the
.
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
231
Managing FLOGI, Name Server, FDMI, and RSCN Databases
Verifying the RSCN Timer Configuration
Note Before performing a downgrade, make sure that you revert the RCSN timer value in your network to the default value. Failure to do so will disable the links across your VSANs and other devices.
To configure the RSCN timer, follow these steps:
Step 1
Step 2
Step 3
Step 4
Step 5 switch# config t switch(config)#
Enters configuration mode.
switch(config)# rscn distribute
Enables RSCN timer configuration distribution.
switch(config)# rscn event-tov 300 vsan 10
Sets the event time-out value in milliseconds for the selected VSAN. In this example, the event time-out value is set to
300 milliseconds for VSAN 12. The range is 0 to 2000 milliseconds. Setting a zero (0) value disables the timer.
switch(config)# no rscn event-tov 300 vsan 10
Reverts to the default value (2000 milliseconds for Fibre Channel VSANs or 1000 milliseconds for FICON VSANs).
switch(config)# rscn commit vsan 10
Commits the RSCN timer configuration to be distributed to the switches in VSAN 10.
Verifying the RSCN Timer Configuration
You verify the RSCN timer configuration using the show rscn event-tov vsan command.
switch# show rscn event-tov vsan 10
Event TOV : 1000 ms
RSCN Timer Configuration Distribution
Because the timeout value for each switch is configured manually, a misconfiguration occurs when different switches time out at different times. This means different N-ports in a network can receive RSCNs at different times. Cisco Fabric Services (CFS) infrastructure alleviates this situation by automatically distributing the
RSCN timer configuration information to all switches in a fabric. This also reduces the number of SW-RSCNs.
Refer to the Cisco MDS 9000 Family NX-OS System Management Configuration Guide .
RSCN supports two modes, distributed and nondistributed. In distributed mode, RSCN uses CFS to distribute configuration to all switches in the fabric. In nondistributed mode, only the configuration commands on the local switch are affected.
232
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Managing FLOGI, Name Server, FDMI, and RSCN Databases
Enabling RSCN Timer Configuration Distribution
Note All configuration commands are not distributed. Only the rscn event-tov tov vsan vsan command is distributed.
Note Only the RSCN timer configuration is distributed.
The RSCN timer is registered with CFS during initialization and switchover. For high availability, if the
RSCN timer distribution crashes and restarts or a switchover occurs, it resumes normal functionality from the state prior to the crash or switchover.
Note You can determine the compatibility when downgrading to an earlier Cisco MDS NX-OS release using show incompatibility system command. You must disable RSCN timer distribution support before downgrading to an earlier release.
Note By default, the RSCN timer distribution capability is disabled and is compatible when upgrading from any
Cisco MDS SAN-OS release earlier than 3.0.
Note For CFS distribution to operate correctly for the RSCN timer configuration, all switches in the fabric must be running Cisco SAN-OS Release 3.0(1) or later, or Cisco NX-OS 4.1(1b).
This section includes the following topics:
Enabling RSCN Timer Configuration Distribution
To enable RSCN timer configuration distribution, follow these steps:
Step 1
Step 2
Step 3 switch# config terminal switch(config)#
Enters configuration mode.
switch(config)# rscn distribute
Enables RSCN timer distribution.
switch(config)# no rscn distribute
Disables (default) RSCN timer distribution.
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
233
Managing FLOGI, Name Server, FDMI, and RSCN Databases
Locking the Fabric
Locking the Fabric
The first action that modifies the database creates the pending database and locks the feature in the VSAN.
Once you lock the fabric, the following situations apply:
• No other user can make any configuration changes to this feature.
• A copy of the configuration database becomes the pending database along with the first active change.
Committing the RSCN Timer Configuration Changes
If you commit the changes made to the active database, the configuration is committed to all the switches in the fabric. On a successful commit, the configuration change is applied throughout the fabric and the lock is released.
To commit RSCN timer configuration changes, follow these steps:
Step 1
Step 2 switch# config t switch(config)#
Enters configuration mode.
switch(config)# rscn commit vsan 10
Commits the RSCN timer changes.
Discarding the RSCN Timer Configuration Changes
If you discard (terminate) the changes made to the pending database, the configuration database remains unaffected and the lock is released.
To discard RSCN timer configuration changes, follow these steps:
Step 1
Step 2 switch# config t switch(config)#
Enters configuration mode.
switch(config)# rscn abort vsan 10
Discards the RSCN timer changes and clears the pending configuration database.
Clearing a Locked Session
If you have changed the RSCN timer configuration and have forgotten to release the lock by either committing or discarding the changes, an administrator can release the lock from any switch in the fabric. If the administrator performs this task, your changes to the pending database are discarded and the fabric lock is released.
234
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Managing FLOGI, Name Server, FDMI, and RSCN Databases
Displaying RSCN Configuration Distribution Information
Tip The pending database is only available in the volatile directory and are subject to being discarded if the switch is restarted.
To use administrative privileges and release a locked DPVM session, use the clear rscn session vsan command in EXEC mode.
switch# clear rscn session vsan 10
Displaying RSCN Configuration Distribution Information
Use the show cfs application name rscn command to display the registration status for RSCN configuration distribution.
switch# show cfs application name rscn
Enabled
Timeout
: Yes
: 5s
Merge Capable : Yes
Scope : Logical
Use the show rscn session status vsan command to display session status information for RSCN configuration distribution.
Note A merge failure results when the RSCN timer values are different on the merging fabrics.
switch# show rscn session status vsan 1
Session Parameters for VSAN: 1
-------------------------------
Last Action : Commit
Last Action Result : Success
Last Action Failure Reason : None
Use the show rscn pending command to display the set of configuration commands that would take effect when you commit the configuration.
Note The pending database includes both existing and modified configuration.
switch# show rscn pending rscn event-tov 2000 ms vsan 1 rscn event-tov 2000 ms vsan 2 rscn event-tov 300 ms vsan 10
Use the show rscn pending-diff command to display the difference between pending and active configurations.
The following example shows the time-out value for VSAN 10 was changed from 2000 milliseconds (default) to 300 milliseconds.
switch# show rscn pending-diff
- rscn event-tov 2000 ms vsan 10
+ rscn event-tov 300 ms vsan 10
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
235
Managing FLOGI, Name Server, FDMI, and RSCN Databases
Default Settings
Default Settings
Table 22: Default RSCN Settings , on page 236
lists the default settings for RSCN.
Table 22: Default RSCN Settings
Parameters
RSCN timer value
Default
2000 milliseconds for Fibre Channel VSANs1000 milliseconds for
FICON VSANs
RSCN timer configuration distribution Disabled
Enabling Port Pacing
For detailed information, refer to the Cisco MDS 9000 Family NX-OS System Management .
236
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Discovering SCSI Targets
C H A P T E R
9
This chapter describes the SCSI LUN discovery feature provided in switches in the Cisco MDS 9000 Family.
It includes the following sections:
•
About SCSI LUN Discovery, on page 237
•
Displaying SCSI LUN Information, on page 239
About SCSI LUN Discovery
Small Computer System Interface (SCSI) targets include disks, tapes, and other storage devices. These targets do not register logical unit numbers (LUNs) with the name server.
The name server requires LUN information for the following reasons:
• To display LUN storage device information so an NMS can access this information.
• To report device capacity, serial number, and device ID information.
• To register the initiator and target features with the name server.
The SCSI LUN discovery feature uses the local domain controller Fibre Channel address. It uses the local domain controller as the source FC ID, and performs SCSI INQUIRY, REPORT LUNS, and READ CAPACITY commands on SCSI devices.
The SCSI LUN discovery feature is initiated on demand, through CLI or SNMP. This information is also synchronized with neighboring switches, if those switches belong to the Cisco MDS 9000 Family.
This section includes the following topics:
About Starting SCSI LUN Discovery
SCSI LUN discovery is done on demand.
Only Nx ports that are present in the name server database and that are registered as FC4 Type = SCSI_FCP are discovered.
Starting SCSI LUN Discovery
To start SCSI LUN discovery, follow one of these steps:
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
237
Discovering SCSI Targets
About Initiating Customized Discovery
Step 1
Step 2
Step 3
Step 4 switch# discover scsi-target local os all
Example: discovery started
Discovers local SCSI targets for all operating systems (OS). The operating system options are aix , all , hpux , linux , solaris , or windows switch# discover scsi-target remote os aix
Example: discovery started
Discovers remote SCSI targets assigned to the AIX OS.
switch# discover scsi-target vsan 1 fcid 0x9c03d6
Example: discover scsi-target vsan 1 fcid 0x9c03d6
VSAN: 1 FCID: 0x9c03d6 PWWN: 00:00:00:00:00:00:00:00
PRLI RSP: 0x01 SPARM: 0x0012
SCSI TYPE: 0 NLUNS: 1
Vendor: Company 4 Model: ST318203FC
Other: 00:00:02:32:8b:00:50:0a
Rev: 0004
Discovers SCSI targets for the specified VSAN (1) and FC ID (0x9c03d6).
switch# discover scsi-target custom-list os linux
Example: discovery started
Discovers SCSI targets from the customized list assigned to the Linux OS.
About Initiating Customized Discovery
Customized discovery consists of a list of VSAN and domain pairs that are selectively configured to initiate a discovery. The domain ID is a number from 0 to 255 in decimal or a number from 0x0 to 0xFF in hex.
Use the custom-list option to initiate this discovery.
Initiating Customized Discovery
To initiate a customized discovery, follow one of these steps:
Step 1 switch# discover custom-list add vsan 1 domain 0X123456
Adds the specified entry to the custom list.
238
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Discovering SCSI Targets
Displaying SCSI LUN Information
Step 2 switch# discover custom-list delete vsan 1 domain 0X123456
Deletes the specified domain ID from the custom list.
Displaying SCSI LUN Information
Use the show scsi-target and show fcns database commands to display the results of the discovery. See
Examples
Displays the Discovered Targets, on page 239
to
Displays Automatically Discovered Targets, on page 241 .
Displays the Discovered Targets switch# show scsi-target status discovery completed
Note This command takes several minutes to complete, especially if the fabric is large or if several devices are slow to respond.
Displays the FCNS Database switch# show fcns database
VSAN 1:
--------------------------------------------------------------------------
FCID TYPE PWWN (VENDOR) FC4-TYPE:FEATURE
--------------------------------------------------------------------------
0xeb0000 N 21:01:00:e0:8b:2a:f6:54 (Qlogic) scsi-fcp:init
0xeb0201 NL 10:00:00:00:c9:32:8d:76 (Emulex)
Total number of entries = 2 scsi-fcp:init
VSAN 7:
--------------------------------------------------------------------------
FCID TYPE PWWN (VENDOR) FC4-TYPE:FEATURE
--------------------------------------------------------------------------
0xed0001 NL 21:00:00:04:cf:fb:42:f8 (Seagate) scsi-fcp:target
Total number of entries = 1
VSAN 2002:
--------------------------------------------------------------------------
FCID TYPE PWWN (VENDOR) FC4-TYPE:FEATURE
--------------------------------------------------------------------------
0xcafe00 N 20:03:00:05:30:00:2a:20 (Cisco)
Total number of entries = 1
FICON:CUP
Displays the Discovered Target Disks switch# show scsi-target disk
--------------------------------------------------------------------------------
VSAN FCID PWWN VENDOR MODEL REV
--------------------------------------------------------------------------------
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
239
Discovering SCSI Targets
Displaying SCSI LUN Information
1
1
1
1
1
1
1
1
1
1
0x9c03d6
0x9c03d9
0x9c03da
0x9c03dc
0x9c03e0
0x9c03e1
0x9c03e2
0x9c03e4
0x9c03e8
0x9c03ef
21:00:00:20:37:46:78:97 Company 4 ST318203FC
21:00:00:20:37:5b:cf:b9 Company 4 ST318203FC
21:00:00:20:37:18:6f:90 Company 4 ST318203FC
21:00:00:20:37:5a:5b:27 Company 4 ST318203FC
21:00:00:20:37:36:0b:4d Company 4 ST318203FC
0004
0004
0004
0004
0004
21:00:00:20:37:39:90:6a Company 4 ST318203 CLAR18 3844
21:00:00:20:37:18:d2:45 Company 4 ST318203 CLAR18 3844
21:00:00:20:37:6b:d7:18 Company 4 ST318203 CLAR18 3844
21:00:00:20:37:38:a7:c1 Company 4 ST318203FC 0004
21:00:00:20:37:18:17:d2 Company 4 ST318203FC 0004
Displays the Discovered LUNs for All Operating Systems switch# show scsi-target lun os all
ST336607FC from SEAGATE (Rev 0006)
FCID is 0xed0001 in VSAN 7, PWWN is 21:00:00:04:cf:fb:42:f8
--------------------------------------------------------------------------------
OS LUN Capacity Status Serial Number Device-Id
(MB)
--------------------------------------------------------------------------------
WIN 0x0 36704 Online 3JA1B9QA00007338 C:1 A:0 T:3 20:00:00:04:cf:fb:42:f8
AIX 0x0
SOL 0x0
LIN 0x0
HP 0x0
36704
36704
36704
36704
Online 3JA1B9QA00007338 C:1 A:0 T:3 20:00:00:04:cf:fb:42:f8
Online 3JA1B9QA00007338 C:1 A:0 T:3 20:00:00:04:cf:fb:42:f8
Online 3JA1B9QA00007338 C:1 A:0 T:3 20:00:00:04:cf:fb:42:f8
Online 3JA1B9QA00007338 C:1 A:0 T:3 20:00:00:04:cf:fb:42:f8
Displays the Discovered LUNs for the Solaris OS switch# show scsi-target lun os solaris
ST336607FC from SEAGATE (Rev 0006)
FCID is 0xed0001 in VSAN 7, PWWN is 21:00:00:04:cf:fb:42:f8
--------------------------------------------------------------------------------
OS LUN Capacity Status Serial Number
(MB)
Device-Id
--------------------------------------------------------------------------------
SOL 0x0 36704 Online 3JA1B9QA00007338 C:1 A:0 T:3 20:00:00:04:cf:fb:42:f8
The following command displays the port WWN that is assigned to each OS (Windows, AIX, Solaris,
Linux, or HPUX)
Displays the pWWNs for each OS switch# show scsi-target pwwn
------------------------------
OS PWWN
------------------------------
WIN 24:91:00:05:30:00:2a:1e
AIX 24:92:00:05:30:00:2a:1e
SOL
LIN
HP
24:93:00:05:30:00:2a:1e
24:94:00:05:30:00:2a:1e
24:95:00:05:30:00:2a:1e
240
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Discovering SCSI Targets
Displaying SCSI LUN Information
Displays Customized Discovered Targets switch# show scsi-target custom-list
---------------
VSAN DOMAIN
---------------
1 56
Use the show scsi-target auto-poll command to verify automatic discovery of SCSI targets that come online. The internal uuid number indicates that a CSM or an IPS module is in the chassis.
Displays Automatically Discovered Targets switch(config)# show scsi-target auto-poll name server polling is enabled auto-polling is disabled, poll_start:0 poll_count:0 poll_type:0
USERS OF AUTO POLLING
---------------------
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
241
Displaying SCSI LUN Information
Discovering SCSI Targets
242
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
C H A P T E R
10
Configuring FICON
Fibre Connection (FICON) interface capabilities enhance the Cisco MDS 9000 Family by supporting both open systems and mainframe storage network environments. The control unit port (CUP) also is supported which allows in-band management of the switch from FICON processors.
This chapter includes the following sections:
•
•
FICON Port Numbering, on page 249
•
Configuring FICON, on page 257
•
Configuring FICON Ports, on page 267
•
FICON Configuration Files, on page 277
•
•
FICON Tape Acceleration, on page 282
•
Configuring XRC Acceleration, on page 286
•
Moving a FICON VSAN to an Offline State, on page 286
•
CUP In-Band Management, on page 287
•
Displaying FICON Information, on page 288
•
About FICON
The Cisco MDS 9000 Family supports the Fibre Channel Protocol (FCP), FICON, iSCSI, and FCIP capabilities within a single, high-availability platform (see
Figure 55: Shared System Storage Network, on page 244 ).
The FICON feature is not supported on:
• Cisco MDS 9120 switches
• Cisco MDS 9124 switches
• Cisco MDS 9140 switches
• The 32-port Fibre Channel switching module
• Cisco Fabric Switch for HP c-Class BladeSystem
• Cisco Fabric Switch for IBM BladeSystem
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
243
Configuring FICON
FICON Requirements
FCP and FICON are different FC4 protocols and their traffic is independent of each other. Devices using these protocols should be isolated using VSANs.
The fabric binding feature helps prevent unauthorized switches from joining the fabric or disrupting current fabric operations (refer to the Cisco MDS 9000 Family NX-OS Security Configuration Guide ). The Registered
Link Incident Report (RLIR) application provides a method for a switch port to send an LIR to a registered
Nx port.
Figure 55: Shared System Storage Network
This section includes the following topics:
FICON Requirements, on page 244
MDS-Specific FICON Advantages, on page 245
FICON VSAN Prerequisites, on page 249
FICON Requirements
The FICON feature has the following requirements:
• You can implement FICON features in the following switches:
• Any switch in the Cisco MDS 9500 Series
• Any switch in the Cisco MDS 9200 Series (including the Cisco MDS 9222i Multiservice Modular
Switch)
• Cisco MDS 9134 Multilayer Fabric Switch
• MDS 9000 Family 18/4-Port Multiservice Module
• You need the MAINFRAME_PKG license to configure FICON parameters.
• To extend your FICON configuration over a WAN link using FCIP, you need the appropriate
SAN_EXTN_OVER_IP license for the module you are using. For more information, refer to the Cisco
NX-OS Family Licensing Guide .
244
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Configuring FICON
MDS-Specific FICON Advantages
MDS-Specific FICON Advantages
This section explains the additional FICON advantages in Cisco MDS switches and includes the following topics:
Fabric Optimization with VSANs
Generally, separate physical fabrics have a high level of switch management and have a higher implementation cost. The ports in each island also may be over-provisioned depending on the fabric configuration.
By using the Cisco MDS-specific VSAN technology, you can have greater efficiency between these physical fabrics by lowering the cost of over-provisioning and reducing the number of switches to be managed. VSANs also help you to move unused ports nondisruptively and provide a common redundant physical infrastructure
(see
Figure 56: VSAN-Specific Fabric Optimization, on page 245
).
Figure 56: VSAN-Specific Fabric Optimization
VSANs enable global SAN consolidation by allowing you to convert existing SAN islands into virtual SAN islands on a single physical network. It provides hardware-enforced security and separation between applications or departments to allow coexistence on a single network. It also allows virtual rewiring to consolidate your storage infrastructure. You can move assets between departments or applications without the expense and disruption of physical relocation of equipment.
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
245
Configuring FICON
FCIP Support
Note While you can configure VSANs in any Cisco MDS switch, you only can enable FICON inupto eight of these
VSANs. The number of VSANs configured depends on the platform.
Mainframe users can think of VSANs as being like FICON LPARs in the MDS SAN fabric. You can partition switch resources into FICON LPARs (VSANs) that are isolated from each other, in much the same way that you can partition resources on a zSeries or DS8000. Each VSAN has its own set of fabric services (such as fabric server and name server), FICON CUP, domain ID, Fabric Shortest Path First (FSPF) routing, operating mode, IP address, and security profile.FICON LPARs can span line cards and are dynamic in size. For example, one FICON LPAR with 10 ports can span 10 different line cards. FICON LPARs can also include ports on more than one switch in a cascaded configuration. The consistent fairness of the Cisco MDS 9000 switching architecture means that “all ports are created equal,” simplifying provisioning by eliminating the “local switching” issues seen on other vendors’ platforms.Addition of ports to a FICON LPAR is a nondisruptive process. The maximum number of ports for a FICON LPAR is 255 due to FICON addressing limitations.
FCIP Support
The multilayer architecture of the Cisco MDS 9000 Family enables a consistent feature set over a protocol-agnostic switch fabric. Cisco MDS 9500 Series and 9200 Series switches transparently integrate
Fibre Channel, FICON, and Fibre Channel over IP (FCIP) in one system. The FICON over FCIP feature enables cost-effective access to remotely located mainframe resources. With the Cisco MDS 9000 Family platform, storage replication services such as IBM PPRC and XRC can be extended over metro to global distances using ubiquitous IP infrastructure which simplifies business continuance strategies.
Refer to the Cisco MDS 9000 Family NX-OS IP Services Configuration Guide .
PortChannel Support
The Cisco MDS implementation of FICON provides support for efficient utilization and increased availability of Inter-Switch Links (ISLs) necessary to build stable large-scale SAN environments. PortChannels ensure an enhanced ISL availability and performance in Cisco MDS switches.
Refer to the Cisco MDS 9000 Family NX-OS Interfaces Configuration Guide for more information on
PortChannels.
VSANs for FICON and FCP Mixing
Cisco MDS 9000 Family FICON-enabled switches simplify deployment of even the most complex mixed environments. Multiple logical FICON, Z-Series Linux/FCP, and Open-Systems Fibre Channel Protocol
(FCP) fabrics can be overlaid onto a single physical fabric by simply creating VSANs as required for each service. VSANs provide both hardware isolation and protocol specific fabric services, eliminating the complexity and potential instability of zone-based mixed schemes.
By default, the FICON feature is disabled in all switches in the Cisco MDS 9000 Family. When the FICON feature is disabled, FC IDs can be allocated seamlessly. Mixed environments are addressed by the Cisco
NX-OS software. The challenge of mixing FCP and FICON protocols are addressed by Cisco MDS switches when implementing VSANs.
Switches and directors in the Cisco MDS 9000 Family support FCP and FICON protocol mixing at the port level. If these protocols are mixed in the same switch, you can use VSANs to isolate FCP and FICON ports.
246
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Configuring FICON
Cisco MDS-Supported FICON Features
Tip When creating a mixed environment, place all FICON devices in one VSAN (other than the default VSAN) and segregate the FCP switch ports in a separate VSAN (other than the default VSAN). This isolation ensures proper communication for all connected devices.
Cisco MDS-Supported FICON Features
The Cisco MDS 9000 Family FICON features include:
• Flexibility and investment protection—The Cisco MDS 9000 Family shares common switching and service modules across the Cisco MDS 9500 Series and the 9200 Series.
Refer to the Cisco MDS 9500 Series Hardware Installation Guide and the Cisco MDS 9200 Series
Hardware Installation Guide.
• High-availability FICON-enabled director—The Cisco MDS 9500 Series combines nondisruptive software upgrades, stateful process restart and failover, and full redundancy of all major components for a new standard in director-class availability. It supports up to 528 autosensing, 4/2/1-Gbps, 10-Gbps, FICON or FCP ports in any combination in a single chassis. Refer to the Cisco MDS 9000 Family NX-OS High
Availability and Redundancy Configuration Guide .
• Infrastructure protection—Common software releases provide infrastructure protection across all Cisco
MDS 9000 platforms. Refer to the Cisco MDS 9000 Family NX-OS Software Upgrade and Downgrade
Guide
• VSAN technology—The Cisco MDS 9000 Family provides VSAN technology for hardware-enforced, isolated environments within a single physical fabric for secure sharing of physical infrastructure and enhanced FICON mixed support. See
Configuring and Managing VSANs, on page 7
• Port-level configurations—There are BB_credits, beacon mode, and port security for each port. Refer to the Cisco MDS 9000 Family NX-OS Interfaces Configuration Guide for information about buffer-to-buffer credits, beacon LEDs, and trunking.
• Alias name configuration—Provides user-friendly aliases instead of the WWN for switches and attached node devices. See
• Comprehensive security framework—The Cisco MDS 9000 Family supports RADIUS and TACACS+ authentication, Simple Network Management Protocol Version 3 (SNMPv3), role-based access control,
Secure Shell Protocol (SSH), Secure File Transfer Protocol (SFTP), VSANs, hardware-enforced zoning,
ACLs, fabric binding, Fibre Channel Security Protocol (FC-SP), LUN zoning, read-only zones, and
VSAN-based access control. Refer to the Cisco MDS 9000 Family NX-OS Security Configuration Guide for information about RADIUS, TACACS+, FC-SP, and DHCHAP.
Note LUN zoning and read-only zones are not supported from Cisco MDS NX-OS
Release 5.x and later.
• Traffic encryption—IPSec is supported over FCIP. You can encrypt FICON and Fibre Channel traffic that is carried over FCIP. Refer to the Cisco MDS 9000 Family NX-OS Security Configuration Guide
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
247
Configuring FICON
Cisco MDS-Supported FICON Features
• Local accounting log—View the local accounting log to locate FICON events. For more information about MSCHAP authentication, and local AAA services, refer to the Cisco MDS 9000 Family NX-OS
Security Configuration Guide
.
• Unified storage management—Cisco MDS 9000 FICON-enabled switches are fully IBM CUP standard compliant for in-band management using the IBM S/A OS/390 I/O operations console. See the
In-Band Management, on page 287
.
• Port address-based configurations—Configure port name, blocked or unblocked state, and the prohibit connectivity attributes can be configured on the ports. See the
Configuring FICON Ports, on page 267 .
• You can display the following information:
• Individual Fibre Channel ports, such as the port name, port number, Fibre Channel address, operational state, type of port, and login data.
• Nodes attached to ports.
• Port performance and statistics.
• Configuration files—Store and apply configuration files. See the
FICON Configuration Files, on page
• FICON and Open Systems Management Server features if installed. —See the
• Enhanced cascading support—See the
CUP In-Band Management, on page 287
.
• Date and time—Set the date and time on the switch. See the
Allowing the Host to Control the Timestamp
• Configure SNMP trap recipients and community names—See the
Configuring SNMP Control of FICON
• Call Home configurations—Configure the director name, location, description, and contact person. Refer to the Cisco MDS 9000 Family NX-OS System Management Configuration Guide.
• Configure preferred domain ID, FC ID persistence, and principal switch priority—For information about configuring domain parameters, refer to the Cisco MDS 9000 Family NX-OS System Management
Configuration Guide .
• Sophisticated SPAN diagnostics—The Cisco MDS 9000 Family provides industry-first intelligent diagnostics, protocol decoding, and network analysis tools as well as integrated Call Home capability for added reliability, faster problem resolution, and reduced service costs. For information about monitoring network traffic using SPAN, refer to the Cisco MDS 9000 Family NX-OS System Management
Configuration Guide
• Configure R_A_TOV, E_D_TOV— See the
Cisco MDS-Supported FICON Features .
• Director-level maintenance tasks—Perform maintenance tasks for the director including maintaining firmware levels, accessing the director logs, and collecting data to support failure analysis. For information about monitoring system processes and logs refer to the Cisco MDS 9000 Family NX-OS System
Management Configuration Guide
• Port-level incident alerts—Display and clear port-level incident alerts. See the
Clearing RLIR Information, on page 276
.
248
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Configuring FICON
FICON Cascading
FICON Cascading
The Cisco MDS NX-OS software allows multiple switches in a FICON network. To configure multiple switches, you must enable and configure fabric binding in that switch and refer to the Cisco MDS 9000 Family
NX-OS Security Configuration Guide ).
FICON VSAN Prerequisites
To ensure that a FICON VSAN is operationally up, be sure to verify the following requirements:
• Set the default zone to permit, if you are not using the zoning feature. See the following Tip:
Tip You do not have to issue the copy running-config startup-config command to store the active zoneset. However, you need to issue the copy running-config startup-config command to explicitly store full zone sets. If there is more than one switch in a fabric, the copy running-config startup-config fabric command should be issued. The fabric keyword causes the copy running-config startup-config command to be issued on all the switches in the fabric, and also saves the full zone information to the startup-config on all the switches in the fabric. This is important in the event of a switch reload or power cycle.
• Enable in-order delivery on the VSAN. See
Configuring Fibre Channel Routing Services and Protocols, on page 181
• Enable (and if required, configure) fabric binding on the VSAN. For more information about Fabric
Binding, refer to the Cisco MDS 9000 Family NX-OS Security Configuration Guide .
• Verify that conflicting persistent FC IDs do not exist in the switch. For information about configuring domain parameters, refer to the Cisco MDS 9000 Family NX-OS System Management Configuration
Guide .
• Verify that the configured domain ID and requested domain ID match. For information about configuring domain parameters, refer to the Cisco MDS 9000 Family NX-OS System Management Configuration
Guide .
• Add the CUP (area FE) to the zone, if you are using zoning. See the
CUP In-Band Management, on page
.
If any of these requirements are not met, the FICON feature cannot be enabled.
FICON Port Numbering
With reference to the FICON feature, ports in Cisco MDS switches are identified by a statically defined 8-bit value known as the port number . A maximum of 255 port numbers are available. You can use the following port numbering schemes:
• Default port numbers based on the chassis type
• Reserved port numbers
This section includes the following topics:
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
249
Configuring FICON
Default FICON Port Numbering Scheme
Note You must enable FICON on the switch before reserving FICON port number (see the
About Enabling FICON on a VSAN, on page 257
).
Default FICON Port Numbering Scheme
Default FICON port numbers are assigned by the Cisco MDS NX-OS software based on the module and the slot in the chassis. The first port in a switch always starts with a zero (0) (see
Number in Numbering on the Cisco MDS 9000 Family Switch, on page 250
).
Figure 57: Default FICON Port Number in Numbering on the Cisco MDS 9000 Family Switch
The default FICON port number is assigned based on the front panel location of the port and is specific to the slot in which the module resides. Thirty-two (32) port numbers are assigned to each slot on all Cisco MDS
9000 Family switches except for the Cisco MDS 9513 Director, which has 16 port numbers assigned for each slot. These default numbers are assigned regardless of the module’s physical presence in the chassis, the port status (up or down), or the number of ports on the module (4, 12, 16, 24, or 48). If a module has fewer ports than the number of port numbers assigned to the slot, then the excess port numbers are unused. If a module has more ports than the number of port numbers assigned to the slot, the excess ports cannot be used for
FICON traffic unless you manually assign the port numbers.
Note You can use the ficon slot assign port-numbers command to make use of any Follow the steps in
FICON Port Numbers to Slots, on page 254
to make use of excess ports by manually assigning more port numbers to the slots. Before doing this, however, we recommend that you review the default port number assignments for Cisco MDS 9000 switches shown in
Table 25: Default FICON Settings , on page 296 Table
23: Default FICON Port Numbering in the Cisco MDS 9000 Family , on page 251 , and that you read the
following sections to gain a complete understanding of FICON port numbering:
Port Numbering Scheme, on page 253 ,
FICON Port Numbering Guidelines, on page 254
, and
Port Numbers to Slots, on page 254
.
250
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Configuring FICON
Default FICON Port Numbering Scheme
Note Only Fibre Channel, PortChannel, and FCIP ports are mapped to FICON port numbers. Other types of interfaces do not have a corresponding port number.
Table 23: Default FICON Port Numbering in the Cisco MDS 9000 Family , on page 251
lists the default port number assignment for the Cisco MDS 9000 Family of switches and directors.
Table 23: Default FICON Port Numbering in the Cisco MDS 9000 Family
Product Slot Number Implemented Port
Allocation
To PortChannel/FCIP Unimplemented Ports
To Ports
Cisco MDS 9200
Series
Cisco MDS 9222i
Series
Cisco MDS 9506
Director
Notes
Slot 1
Slot 2
Slot 1
Slot 2
0 through 31
32 through 63
0 through 31
32 through 63
64 through 89
64 through 89
128 through 153
90 through 253 and port 255
Similar to a switching module.
90 through 253 and port 255
The first 4, 12, 16, or 24 port numbers in a 4-port, 12-port,
16-port, or 24-port module are used and the rest remain unused. Extra 16 ports on 48-port modules are not allocated numbers.
154 through 253 and port 255
Supervisor modules are not allocated port numbers.
Cisco MDS 9134
Director
Slot 1
Slot 2
Slot 3
Slot 4
Slot 5
Slot 6
Slot 1
0 through 31
32 through 63
64 through 95
96 through 127
None
None
0 through 33 34 through 59 60 through 253 and port 255
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
251
Configuring FICON
Default FICON Port Numbering Scheme
Product
Cisco MDS 9509
Director
Slot Number
Slot 1
Slot 2
Slot 3
Slot 4
Slot 5
Slot 6
Slot 7
Slot 8
Slot 9
Cisco MDS 9513
Director
Slot 2
Slot 3
Slot 4
Slot 5
Slot 6
Slot 7
Slot 8
Slot 1
16 through 31
32 through 47
48 through 63
64 through 79
80 through 95
None
None
Implemented Port
Allocation
0 through 31
32 through 63
64 through 95
96 through 127
None
None
128 through 159
160 through 191
192 through 223
0 through 15
To PortChannel/FCIP Unimplemented Ports
224 through 249
224 through 249
250 through 253 and port 255
The first 4, 12, 16, or 24 port numbers in a 4-port, 12-port,
16-port, or 24-port module are used and the rest remain unused. Extra 16 ports on 48-port modules are not allocated port numbers.
Supervisor modules are not allocated port numbers.
The first 4, 12, 16, or 24 port numbers are used for a
4-port,
12-port,16-port, or
24-port module and the rest remain unused. Extra 16 ports on 48-port modules are not allocated port numbers.
250 through 253 and port 255
The first 4, 12 or 16 port numbers are used for a 4-port,
12-port or 16-port module and the rest remain unused.
Extra ports on
24-port, 32-port, and
48-port modules are not allocated port numbers.
Supervisor modules are not allocated port numbers.
252
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Configuring FICON
Port Addresses
Product
Slot 9
Slot 10
Slot 11
Slot 12
Slot 13
Slot Number
96 through 111
112 through 127
128 through 143
144 through 159
160 through 175
Implemented Port
Allocation
The first 4 or 12 port numbers are used for a 4-port or 12-port module and the rest remain unused. Extra ports on 24-port,
32-port, and 48-port modules are not allocated port numbers.
To PortChannel/FCIP Unimplemented Ports
Port Addresses
By default, port numbers are the same as port addresses. You can swap the port addresses (see the
).
You can swap the port addresses by issuing the ficon swap portnumber command.
Implemented and Unimplemented Port Addresses
An implemented port refers to any port address that is assigned by default to a slot in the chassis (see
). An unimplemented port refers to any port address that is not assigned by default to a slot in the chassis (see
Default Settings, on page 296 ).
About the Reserved FICON Port Numbering Scheme
A range of 250 port numbers are available for you to assign to all the ports on a switch.
shows that you can have more than 250 physical ports on a switch and the excess ports do not have port numbers in the default numbering scheme. When you have more than 250 physical ports on your switch, you can have ports without a port number assigned if they are not in a FICON VSAN, or you can assign duplicate port numbers if they are not used in the same FICON VSAN. For example, you can configure port number 1 on interface fc1/1 in FICON VSAN 10 and fc10/1 in FICON VSAN 20.
Note A VSAN can have a maximum of 250 port numbers.
Note FICON port numbers are not changed for ports that are active. You must first disable the interfaces using the shutdown command.
Note You can configure port numbers even when no module is installed in the slot.
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
253
Configuring FICON
Installed and Uninstalled Ports
Installed and Uninstalled Ports
An installed port refers to a port for which all required hardware is present. A specified port number in a
VSAN can be implemented, and yet not installed, if any of the following conditions apply:
• The module is not present—For example, if module 1 is not physically present in slot 1 in a Cisco MDS
9509 Director, ports 0 to 31 are considered uninstalled.
• The small form-factor pluggable (SFP) port is not present—For example, if a 16-port module is inserted in slot 2 in a Cisco MDS 9509 Director, ports 48 to 63 are considered uninstalled.
• For slot 1, ports 0 to 31, or 0 to 15 have been assigned. Only the physical port fc1/5 with port number 4 is in VSAN 2. The rest of the physical ports are not in VSAN 2. The port numbers 0 to 249 are considered implemented for any FICON-enabled VSAN. Therefore, VSAN 2 has port numbers 0 to 249 and one physical port, fc1/4. The corresponding physical ports 0 to 3,and 5 to 249 are not in VSAN 2. When the
FICON VSAN port address is displayed, those port numbers with the physical ports not in VSAN 2 are not installed (for example, ports 0 to 3, or 5 to 249).
Another scenario is if VSANs 1 through 5 are FICON-enabled, and trunking-enabled interface fc1/1 has
VSANs 3 through 10, then port address 0 is uninstalled in VSAN 1 and 2.
• The port is part of a PortChannel—For example, if interface fc 1/1 is part of PortChanne1 5, port address
0 is uninstalled in all FICON VSANs. See
Default Settings, on page 296 .
FICON Port Numbering Guidelines
The following guidelines apply to FICON port numbers:
• Supervisor modules do not have port number assignments.
• Port numbers do not change based on TE ports. Since TE ports appear in multiple VSANs, chassis-wide unique port numbers should be reserved for TE ports.
• Each PortChannel must be explicitly associated with a FICON port number.
• When the port number for a physical PortChannel becomes uninstalled, the relevant PortChannel configuration is applied to the physical port.
• Each FCIP tunnel must be explicitly associated with a FICON port number. If the port numbers are not assigned for PortChannels or for FCIP tunnels, then the associated ports will not come up.
See the
About Port Numbers for FCIP and PortChannel, on page 255
.
Assigning FICON Port Numbers to Slots
You can use the show ficon port-number assign and show ficon first-available port-number commands to determine which port numbers to use.
Caution When you assign, change, or release a port number, the port reloads.
To assign FICON port numbers to a slot, follow these steps:
Step 1 switch# config t switch(config)#
254
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Configuring FICON
Displaying the FICON Port Number Assignments
Step 2
Step 3
Step 4
Step 5
Step 6
Enters configuration mode.
switch(config)# ficon slot 3 assign port-numbers 0-15, 48-63
Reserves FICON port numbers 0 through 15 and 48 through 63 for up to 32 interfaces in slot 3.
switch(config)# ficon slot 3 assign port-numbers 0-15, 17-32
Reserves FICON port numbers 0 through 15 for the first 16 interfaces and 17 through 32 for the next 16 interfaces in slot
3.
switch(config)# ficon slot 3 assign port-numbers 0-63
Reserves FICON port numbers 0 through 63 for up to 64 interfaces in slot 3.
switch(config)# ficon slot 3 assign port-numbers 0-15, 56-63
Changes the reserved FICON port numbers for up to 24 interfaces in slot 3.
switch(config)# no ficon slot 3 assign port-numbers 0-15, 56-63
(Optional) Releases the FICON port numbers.
Displaying the FICON Port Number Assignments
Use the show ficon port-numbers assign command to display the port numbers assigned on the switch.
switch# show ficon port-numbers assign ficon slot 1 assign port-numbers 0-31 ficon slot 2 assign port-numbers 32-63 ficon slot 3 assign port-numbers 64-95 ficon slot 4 assign port-numbers 96-127 ficon logical-port assign port-numbers 128-153
Use the show ficon port-numbers assign slot command to display the port numbers assigned to a specific slot.
switch# show ficon port-numbers assign slot 2 ficon slot 2 assign port-numbers 32-63
Use the show ficon port-numbers assign command to display the port numbers reserved for logical ports.
switch# show ficon port-numbers assign logical-port ficon logical-port assign port-numbers 128-153
About Port Numbers for FCIP and PortChannel
FCIP and PortChannels cannot be used in a FICON-enabled VSAN unless they are explicitly bound to a port number.
See the
Configuring FICON Ports, on page 267 , and the
Reserving FICON Port Numbers for FCIP and
PortChannel Interfaces, on page 256 , and the
Binding Port Numbers to FCIP Interfaces , on page 268
.
You can use the default port numbers if they are available (see
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
255
Configuring FICON
Reserving FICON Port Numbers for FCIP and PortChannel Interfaces are not reserved for Fibre Channel interfaces (see the
About the Reserved FICON Port Numbering Scheme, on page 253 ).
To find the first available port number to bind an FCIP or PortChannel interface, use the show ficon first-available port-number command (see
Displays the Available Port Numbers, on page 289 ).
Tip The show ficon vsan portaddress brief command displays the port number to interface mapping. You can assign port numbers in the PortChannel/FCIP range that are not already assigned to a PortChannel or FCIP interface (see
Displays Port Address Information in a Brief Format, on page 289 ).
Reserving FICON Port Numbers for FCIP and PortChannel Interfaces
You must reserve port numbers for logical interfaces, such as FCIP and PortChannels, if you plan to use them.
To reserve FICON port numbers for logical interfaces, follow these steps:
Step 1
Step 2
Step 3
Step 4 switch# config t switch(config)#
Enters configuration mode.
switch(config)# ficon logical-port assign port-numbers 230-249
Reserves port numbers 230 through 249 for FCIP and PortChannel interfaces.
switch(config)# ficon logical-port assign port-numbers 0xe6-0xf9
Reserves port numbers 0xe6 through 0xf9 for FCIP and PortChannel interfaces.
Note You cannot change port numbers that are active. You must disable the interfaces using the shutdown command and unbind port numbers using the no ficon portnumber command. See the
Configuring FICON Ports, on page 267 .
switch(config)# no ficon logical-port assign port-numbers 230-249
Releases the port numbers.
Note You cannot release port numbers for interfaces that are active.You must disable the interfaces using the shutdown command and unbind port numbers using the no ficon portnumber command. See the
FC ID Allocation
FICON requires a predictable and static FC ID allocation scheme. When FICON is enabled, the FC ID allocated to a device is based on the port address of the port to which it is attached. The port address forms the middle byte of the fabric address. Additionally, the last byte of the fabric address should be the same for all devices in the fabric. By default, the last byte value is 0 and can be configured.
256
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Configuring FICON
Configuring FICON
Note You cannot configure persistent FC IDs in FICON-enabled VSANs.
Cisco MDS switches have a dynamic FC ID allocation scheme. When FICON is enabled or disabled on a
VSAN, all the ports are shut down and restarted to switch from the dynamic to static FC IDs and vice versa
(see
Figure 58: Static FC ID Allocation for FICON, on page 257
).
Figure 58: Static FC ID Allocation for FICON
Configuring FICON
By default FICON is disabled in all switches in the Cisco MDS 9000 Family. You can enable FICON on a per VSAN basis by using the Device Manager.
This section includes the following topics:
About Enabling FICON on a VSAN
By default FICON is disabled in all VSANs on the switch.
You can enable FICON on a per VSAN basis in one of the following ways:
• Use the automated setup ficon command.
See the
Setting Up a Basic FICON Configuration, on page 258 .
• Manually address each prerequisite.
See the
• Use Device Manager.
When you enable the FICON feature in Cisco MDS switches, the following restrictions apply:
• You cannot disable in-order delivery for the FICON-enabled VSAN.
• You cannot disable fabric binding or static domain ID configurations for the FICON-enabled VSAN.
• The load balancing scheme is changed to Source ID (SID)—Destination ID (DID). You cannot change it back to SID—DID—OXID.
• The IPL configuration file is automatically created.
See the
About FICON Configuration Files, on page 277
.
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
257
Configuring FICON
Enabling FICON on the Switch
Tip Using Device Manager, FICON auto-save can be invoked by multiple users logged on to the same
FICON-enabled switch. Device Manager performs a periodic auto-save on any FICON-enabled switch causing increments in the FICON key counter. These increments highlight a change that has actually not occurred.
To avoid this we recommend that only one instance of Device Manager monitor a FICON-enabled switch.
Enabling FICON on the Switch
By default FICON is disabled in all switches in the Cisco MDS 9000 Family. You can enable FICON on the switch either explicitly or implicitly by enabling FICON on a VSAN. However, disabling FICON on all
VSANs does not disable FICON on the switch. You must explicitly disable FICON.
To explicitly enable or disable FICON globally on the switch, follow these steps:
Step 1
Step 2
Step 3 switch# config t switch(config)#
Enters configuration mode.
switch(config)# feature ficon
Enables FICON globally on the switch.
switch(config)# no feature ficon
Disables FICON globally on the switch and removes all FICON configuration.
Setting Up a Basic FICON Configuration
This section steps you through the procedure to set up FICON on a specified VSAN in a Cisco MDS 9000
Family switch.
Note Press Ctrl-C at any prompt to skip the remaining configuration options and proceed with what is configured until that point.
Step 1
Tip If you do not want to answer a previously configured question, or if you want to skip answers to any questions, press Enter . If a default answer is not available (for example, switch name), the switch uses what was previously configured and skips to the next question.
To enable and set up FICON, follow these steps:
Enter the setup ficon command at the EXEC command mode.
258
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Configuring FICON
Setting Up a Basic FICON Configuration
Step 2
Step 3
Step 4
Step 5
Step 6
Step 7
Step 8 switch# setup ficon
--- Ficon Configuration Dialog ---
This setup utility will guide you through basic Ficon Configuration on the system.
Press Enter if you want to skip any dialog. Use ctrl-c at anytime to skip all remaining dialogs.
Enter yes (the default is yes ) to enter the basic FICON configuration setup.
Would you like to enter the basic configuration dialog (yes/no) [yes]: yes
The FICON setup utility guides you through the basic configuration process. Press Ctrl-C at any prompt to end the configuration process.
Enter the VSAN number for which FICON should be enabled.
Enter vsan [1-4093]: 2
Enter yes (the default is yes ) to create a VSAN.
vsan 2 does not exist, create it? (yes/no) [yes]: yes
Enter yes (the default is yes ) to confirm your VSAN choice:
Enable ficon on this vsan? (yes/no) [yes]: yes
Note At this point, the software creates the VSAN if it does not already exist.
Enter the domain ID number for the specified FICON VSAN.
Configure domain-id for this ficon vsan (1-239): 2
Enter yes (the default is no ) to set up FICON in cascaded mode. If you enter no , skip to step 8 (see the
Would you like to configure ficon in cascaded mode: (yes/no) [no]: yes a) Assign the peer WWN for the FICON: CUP.
Configure peer wwn (hh:hh:hh:hh:hh:hh:hh:hh): 11:00:02:01:aa:bb:cc:00 b) Assign the peer domain ID for the FICON: CUP
Configure peer domain (1-239) : 4 c) Enter yes if you wish to configure additional peers (and repeat Steps 7a and 7b). Enter no , if you do wish to configure additional peers.
Would you like to configure additional peers: (yes/no) [no]: no
Enter yes (the default is yes ) to allow SNMP permission to modify existing port connectivity parameters (see the
Configuring SNMP Control of FICON Parameters, on page 265
).
Enable SNMP to modify port connectivity parameters? (yes/no) [yes]: yes
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
259
Configuring FICON
Setting Up a Basic FICON Configuration
Step 9
Step 10
Step 11
Step 12
Step 13
Step 14
Enter no (the default is no ) to allow the host (mainframe) to modify the port connectivity parameters, if required (see the
Allowing the Host to Change FICON Port Parameters, on page 263
).
Disable Host from modifying port connectivity parameters? (yes/no) [no]: no
Enter yes (the default is yes ) to enable the active equals saved feature (see the
Automatically Saving the Running
Disable Host from modifying port connectivity parameters? (yes/no) [no]: no
Enter yes (the default is yes ) if you wish to configure additional FICON VSANs.
Disable Host from modifying port connectivity parameters? (yes/no) [no]: no
Review and edit the configuration that you have just entered.
Enter no (the default is no ) if you are satisfied with the configuration.
Note For documentation purposes, the following configurations shows three VSANs with different FICON settings.
These settings provide a sample output for different FICON scenarios.
The following configuration will be applied: fcdomain domain 2 static vsan 1 fcdomain restart disruptive vsan 1 fabric-binding database vsan 1 swwn 11:00:02:01:aa:bb:cc:00 domain 4 fabric-binding activate vsan 1 zone default-zone permit vsan 1 ficon vsan 1 no host port control fcdomain domain 3 static vsan 2 fcdomain restart disruptive vsan 2 fabric-binding activate vsan 2 force zone default-zone permit vsan 2 ficon vsan 2 no host port control no active equals saved vsan database vsan 3 fcdomain domain 5 static vsan 3 fcdomain restart disruptive vsan 3 fabric-binding activate vsan 3 force zone default-zone permit vsan 3 ficon vsan 3 no snmp port control no active equals saved
Would you like to edit the configuration? (yes/no) [no]: no
Enter yes (the default is yes ) to use and save this configuration. The implemented commands are displayed. After
FICON is enabled for the specified VSAN, you are returned to the EXEC mode switch prompt.
Use this configuration and apply it? (yes/no) [yes]: yes
`fcdomain domain 2 static vsan 1`
`fcdomain restart disruptive vsan 1`
`fabric-binding database vsan 1`
`swwn 11:00:02:01:aa:bb:cc:00 domain 4`
`fabric-binding activate vsan 1`
`zone default-zone permit vsan 1`
`ficon vsan 1`
260
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Configuring FICON
Manually Enabling FICON on a VSAN
`no host port control`
`fcdomain domain 3 static vsan 2`
`fcdomain restart disruptive vsan 2`
`fabric-binding activate vsan 2 force`
`zone default-zone permit vsan 2`
`ficon vsan 2`
`no host port control`
`no active equals saved`
Note If a new VSAN is created, two additional commands are displayed— vsan database and vsan number .
`vsan database`
`vsan 3`
`in-order-guarantee vsan 3`
`fcdomain domain 2 static vsan 3`
`fcdomain restart disruptive vsan 3`
`fabric-binding activate vsan 3 force`
`zone default-zone permit vsan 3`
`ficon vsan 3`
`no snmp port control`
Performing fast copy config...done.
switch#
Manually Enabling FICON on a VSAN
Note This section describes the procedure to manually enable FICON on a VSAN. If you have already enabled
FICON on the required VSAN using the automated setup (recommended), skip to the
Automatically Saving the Running Configuration, on page 266
.
To manually enable FICON on a VSAN, follow these steps:
Step 1
Step 2
Step 3 switch# config t switch(config)#
Enters configuration mode.
switch(config)# vsan database switch(config-vsan-db)# switch(config-vsan-db)# vsan 5 do show vsan usage
4 vsan configured configured vsans:1-2,5,26 vsans available for configuration:3-4,6-25,27-4093 switch(config-vsan-db)# exit
Enables VSAN 5.
switch(config)# in-order-guarantee vsan 5
Activates in-order delivery for VSAN 5.
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
261
Configuring FICON
Configuring the code-page Option
Step 4
Step 5
Step 6
Step 7
Step 8
Step 9
See
Configuring Fibre Channel Routing Services and Protocols, on page 181
switch(config)# fcdomain domain 2 static vsan 2
Configures the domain ID for VSAN 2.
For information about configuring domain parameters, refer to the Cisco MDS 9000 Family NX-OS System Management
Configuration Guide .
switch(config)# fabric-binding activate vsan 2 force
Activates fabric binding on VSAN 2.
Refer to the Cisco MDS 9000 Family NX-OS Security Configuration Guide switch(config)# zone default-zone permit vsan 2
Sets the default zone to permit for VSAN 2.
See the
CUP In-Band Management, on page 287
.
switch(config)# ficon vsan 2 switch(config-ficon)#
Enables FICON on VSAN 2.
switch(config)# no ficon vsan 6
Disables the FICON feature on VSAN 6.
switch(config-ficon)# no host port control
Prohibits mainframe users from moving the switch to an offline state.
See the
Allowing the Host to Move the Switch Offline, on page 263
.
Configuring the code-page Option
FICON strings are coded in Extended Binary-Coded Decimal Interchange Code (EBCDIC) format. Refer to your mainframe documentation for details on the code page options.
Cisco MDS switches support international-5 , france , brazil , germany , italy , japan , spain-latinamerica , uk , and us-canada (default) EBCDIC format options.
Tip This is an optional configuration. If you are not sure of the EBCDIC format to be used, we recommend retaining the us-canada (default) option.
To configure the code-page option in a VSAN, follow these steps:
Step 1 switch# config t switch(config)#
Enters configuration mode.
262
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Configuring FICON
Allowing the Host to Move the Switch Offline
Step 2
Step 3
Step 4 switch(config)# ficon vsan 2 switch(config-ficon)#
Enables FICON on VSAN 2.
switch(config-ficon)# code-page italy
Configures the italy EBCDIC format.
switch(config-ficon)# no code-page
(Optional) Reverts to the factory default of using the us-canada EBCDIC format.
Allowing the Host to Move the Switch Offline
By default, hosts are allowed to move the switch to an offline state. To do this, the host sends a "Set offline" command (x'FD') to the CUP.
To allow the host to move the switch to an offline state, follow these steps:
Step 1
Step 2
Step 3
Step 4 switch# config terminal switch(config)#
Enters configuration mode.
switch(config)# ficon vsan 2 switch(config-ficon)#
Enables FICON on VSAN 2.
switch(config-ficon)# no host control switch offline
Prohibits mainframe users from moving the switch to an offline state.
switch(config-ficon)# host control switch offline
Allows the host to move the switch to an offline state (default) and shuts down the ports.
Allowing the Host to Change FICON Port Parameters
By default, mainframe users are not allowed to configure FICON parameters on Cisco MDS switches—they can only query the switch.
Use the host port control command to permit mainframe users to configure FICON parameters.
To allow the host (mainframe) to configure FICON parameters on the Cisco MDS switch, follow these steps:
Step 1 switch# config terminal switch(config)#
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
263
Configuring FICON
Allowing the Host to Control the Timestamp
Step 2
Step 3
Step 4
Enters configuration mode.
switch(config)# ficon vsan 2 switch(config-ficon)#
Enables FICON on VSAN 2.
switch(config-ficon)# no host port control
Prohibits mainframe users from configuring FICON parameters on the Cisco MDS switch.
switch(config-ficon)# host port control
Allows mainframe users to configure FICON parameters on the Cisco MDS switch (default).
Allowing the Host to Control the Timestamp
By default, the clock in each VSAN is the same as the switch hardware clock. Each VSAN in a Cisco MDS
9000 Family switch represents a virtual director. The clock and time present in each virtual director can be different.To maintain separate clocks for each VSAN, the Cisco NX-OS software maintains the difference of the VSAN-specific clock and the hardware-based director clock. When a host (mainframe) sets the time, the
Cisco NX-OS software updates this difference between the clocks. When a host reads the clock, it computes the difference between the VSAN-clock and the current director hardware clock and presents a value to the mainframe.
The VSAN-clock current time is reported in the output of show ficon vsan vsan-id , show ficon , and show accounting log commands.
To configure host control of the timestamp, follow these steps:
Step 1
Step 2
Step 3
Step 4 switch# config terminal switch(config)#
Enters configuration mode.
switch(config)# ficon vsan 2 switch(config-ficon)#
Enables FICON on VSAN 2.
switch(config-ficon)# no host set-timestamp
Prohibits mainframe users from changing the VSAN-specific clock.
switch(config-ficon)# host set-timestamp
Allows the host to set the clock on this switch (default).
264
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Configuring FICON
Clearing the Time Stamp
Clearing the Time Stamp
Note You can clear time stamps only from the Cisco MDS switch—not the mainframe.
Use the clear ficon vsan vsan-id timestamp command in EXEC mode to clear the VSAN clock.
switch# clear ficon vsan 20 timestamp
Configuring SNMP Control of FICON Parameters
To configure SNMP control of FICON parameters, follow these steps:
Step 1
Step 2
Step 3
Step 4 switch# config t switch(config)#
Enters configuration mode.
switch(config)# ficon vsan 2 switch(config-ficon)#
Enables FICON on VSAN 2.
switch(config-ficon)# no snmp port control
Prohibits SNMP users from configuring FICON parameters.
switch(config-ficon)# snmp port control
Allows SNMP users to configure FICON parameters (default).
About FICON Device Allegiance
FICON requires serialization of access among multiple mainframes, CLI, and SNMP sessions be maintained on Cisco MDS 9000 Family switches by controlling device allegiance for the currently executing session.
Any other session is denied permission to perform configuration changes unless the required allegiance is available.
Caution This task discards the currently executing session.
Clearing FICON Device Allegiance
You can clear the current device allegiance by issuing the clear ficon vsan vsan-id allegiance command in
EXEC mode.
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
265
Configuring FICON
Automatically Saving the Running Configuration switch# clear ficon vsan 1 allegiance
Automatically Saving the Running Configuration
Cisco MDS NX-OS provides an option to automatically save any configuration changes to the startup configuration. This ensures that the new configuration is present after a switch reboot. By default, the
Active=Saved active equals saved option is automatically enabled on any FICON VSAN.
Table 24: Saving the Active FICON and Switch Configuration , on page 266
displays the results of the Active
= Saved option active equals saved command and the implicit copy from the running configuration to the startup configuration ( copy running start ) copy running-config startup-config command in various scenarios.
When the Active=Saved option active equals saved command is enabled in any FICON-enabled VSAN in the fabric, then the following apply (see Number 1 and 2 in
Table 24: Saving the Active FICON and Switch
):
• All configuration changes (FICON-specific or not) are automatically saved to persistent storage (implicit copy running start ) and stored in the startup configuration.
• FICON-specific configuration changes are immediately saved to the IPL file (see the
).
If the Active=Saved option active equals saved command is not enabled in any FICON-enabled VSAN in the fabric, then FICON-specific configuration changes are not saved in the IPL file and an implicit copy running startup command is not issued, you must explicitly save the running configuration to the startup configurationissue the copy running start command explicitly (see number 3 in
FICON and Switch Configuration , on page 266 ).
Table 24: Saving the Active FICON and Switch Configuration
Number FICON-enabled
VSAN?
1 Yes active equals saved
Enabled?
Implicit copy running start
Issued?
Yes (in all FICON VSANs) Implicit
Notes
2
3
Yes
Yes
Yes (even in one FICON
VSAN)
Implicit
Not in any FICON VSAN Not implicit
FICON changes written to the IPL file.
Non-FICON changes saved to startup configuration and persistent storage.
FICON changes written to IPL file for only the VSAN that has active equals saved option enabled.
Non-FICON changes saved to startup configuration and persistent storage.
FICON changes are not written to the IPL file.
Non-FICON changes are saved in persistent storage—only if you explicitly issue the copy running start command.
4 No Not applicable
266
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Configuring FICON
Configuring FICON Ports
Note If active equals saved is enabled, the Cisco NX-OS software ensures that you do not have to perform the copy running startup command for the FICON configuration as well. If your switch or fabric consists of multiple FICON-enabled VSANs, and one of these VSANs have active equals saved enabled, changes made to the non-FICON configuration results in all configurations being saved to the startup configuration.
To automatically save the running configuration, follow these steps:
Step 1
Step 2
Step 3
Step 4 switch# config terminal switch(config)#
Enters configuration mode.
switch(config)# ficon vsan 2 switch(config-ficon)#
Enables FICON on VSAN 2.
switch(config-ficon)# active equals saved
Enables the automatic save feature for all VSANs in the switch or fabric.
switch(config-ficon)# no active equals saved
(Optional) Disables automatic save for this VSAN.
Configuring FICON Ports
You can perform FICON configurations on a per-port address basis in the Cisco MDS 9000 Family switches.
Even if a port is uninstalled, the port address-based configuration is accepted by the Cisco MDS switch. This configuration is applied to the port when the port becomes installed.
This section includes the following topics:
Binding Port Numbers to PortChannels
Caution All port number assignments to PortChannels or FCIP interfaces are lost (cannot be retrieved) when FICON is disabled on all VSANs.
You can bind (or associate) a PortChannel with a FICON port number to bring up that interface.
To bind a PortChannel with a FICON port number, follow these steps:
Step 1 switch# config terminal
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
267
Configuring FICON
Binding Port Numbers to FCIP Interfaces
Step 2
Step 3 switch(config)#
Enters configuration mode.
switch(config)# interface Port-channel 1 switch(config-if)#
Enters the PortChannel interface configuration mode.
switch(config-if)# ficon portnumber 234
Assigns the FICON port number to the selected PortChannel port.
Binding Port Numbers to FCIP Interfaces
You can bind (or associate) an FCIP interface with a FICON port number to bring up that interface.
To bind an FCIP interface with a FICON port number, follow these steps:
Step 1
Step 2
Step 3 switch# config t switch(config)#
Enters configuration mode.
switch1(config)# interface fcip 51 switch1(config-if)#
Creates an FCIP interface (51).
switch(config-if)# ficon portnumber 208
Assigns the FICON port number to the selected FCIP interface.
Configuring Port Blocking
If you block a port, the port is retained in the operationally down state. If you unblock a port, a port initialization is attempted. When a port is blocked, data and control traffic are not allowed on that port.
Physical Fibre Channel port blocks will continue to transmit an Off-line state (OLS) primitive sequence on a blocked port.
Note The zoning devices within a FICON VSAN can conflict with currently prohibited FICON ports and should not be used. IBM does not recommend using zoning and port prohibition within the same VSAN.
268
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Configuring FICON
Port Prohibiting
Caution You cannot block or prohibit the CUP port (0XFE).
If a port is shut down, unblocking that port does not initialize the port.
Note The shutdown / no shutdown port state is independent of the block / no block port state.
To block or unblock port addresses in a VSAN, follow these steps:
Step 1
Step 2
Step 3
Step 4
Step 5 switch# config terminal switch(config)#
Enters configuration mode.
switch(config)# ficon vsan 2 switch(config-ficon)#
Enables FICON on VSAN 2.
switch(config-ficon)# portaddress 1 - 5 switch(config-ficon-portaddr)#
Selects port address 1 to 5 for further configuration.
switch(config-ficon-portaddr)# block
Disables a range of port addresses and retains it in the operationally down state.
switch(config-ficon-portaddr)# no block
Enables the selected port address and reverts to the factory default of the port address not being blocked.
Port Prohibiting
To prevent implemented ports from talking to each other, configure prohibits between two or more ports. If you prohibit ports, the specified ports are prevented from communicating with each other.
Tip You cannot prohibit a PortChannel or FCIP interface.
Unimplemented ports are always prohibited. In addition, prohibit configurations are always symmetrically applied—if you prohibit port 0 from talking to port 15, port 15 is automatically prohibited from talking to port 0.
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
269
Configuring FICON
Configuring the Default State for Port Prohibiting
Note If an interface is already configured in E or TE mode and you try to prohibit that port, your prohibit configuration is rejected. Similarly, if a port is not up and you prohibit that port, the port is not allowed to come up in E mode or in TE mode.
Configuring the Default State for Port Prohibiting
By default, port prohibiting is disabled on the implemented interfaces on the switch. As of Cisco MDS SAN-OS
Release 3.0(2), you can change the default port prohibiting state to enabled in VSANs that you create and then selectively disable port prohibiting on implemented ports, if desired. Also, only the FICON configuration files created after you change the default have the new default setting (see the
FICON Configuration Files, on page 277 ).
To change the default port prohibiting setting for all implemented interfaces on the switch, follow these steps:
Step 1
Step 2
Step 3 switch# config terminal switch(config)#
Enters configuration mode.
switch(config)# ficon port default-state prohibit-all
Enables port prohibiting as the default for all implemented interfaces on the switch.
switch(config)# no ficon port default-state prohibit-all
Disables (default) port prohibiting as the default for all implemented interfaces on the switch.
Configuring Port Prohibiting
To prohibit port addresses in a VSAN, follow these steps:
Step 1
Step 2
Step 3
Step 4 switch# config t switch(config)#
Enters configuration mode.
switch(config)# ficon vsan 2 switch(config-ficon)#
Enables FICON on VSAN 2.
switch(config-ficon)# portaddress 7 switch(config-ficon-portaddr)#
Selects port address 7 for further configuration.
switch(config-ficon-portaddr)# prohibit portaddress 3-5
270
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Configuring FICON
Assigning a Port Address Name
Step 5
Prohibits port address 7 in VSAN 2 from talking to ports 3, 4, and 5.
switch(config-ficon-portaddr)# no prohibit portaddress 5
Removes port address 5 from a previously prohibited state.
Assigning a Port Address Name
To assign a port address name, follow these steps:
Step 1
Step 2
Step 3
Step 4
Step 5 switch# config t switch(config)#
Enters configuration mode.
switch(config)# ficon vsan 2 switch(config-ficon)#
Enables FICON on VSAN 2.
switch(config-ficon)# portaddress 7 switch(config-ficon-portaddr)#
Selects port address 7 for further configuration.
switch(config-ficon-portaddr)# name SampleName
Assigns a name to the port address.
Note The port address name is restricted to 24 alphanumeric characters.
switch(config-ficon-portaddr)# no name SampleName
Deletes a previously configured port address name.
About RLIR
The Registered Link Incident Report (RLIR) application provides a method for a switch port to send an Link
Incident Record (LIR) to a registered Nx port.
When an LIR is detected in FICON-enabled switches in the Cisco MDS 9000 Family from a RLIR Extended
Link Service (ELS), the switch sends that record to the members in its Established Registration List (ERL).
In case of multiswitch topology, a Distribute Registered Link Incident Record (DRLIR) Inter-Link Service
(ILS) is sent to all reachable remote domains along with the RLIR ELS. On receiving the DRLIR ILS, the switch extracts the RLIR ELS and sends it to the members of the ERL.
The Nx ports interested in receiving the RLIR ELS send the Link Incident Record Registration (LIRR) ELS request to the management server on the switch. The RLIRs are processed on a per-VSAN basis.
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
271
Configuring FICON
Specifying an RLIR Preferred Host
The RLIR data is written to persistent storage when you enter the copy running-config startup-config command.
The RLIR data is written to persistent storage when you copy the running configuration to the startup configuration.
Specifying an RLIR Preferred Host
As of Cisco MDS SAN-OS Release 3.0(3), you can specify a preferred host to receive RLIR frames. The
MDS switch sends RLIR frames to the preferred host only if it meets the following conditions:
• No host in the VSAN is registered for RLIR with the registration function set to “always receive.” If one or more hosts in the VSAN are registered as “always receive,” then RLIR sends only to these hosts and not to the configured preferred host.
• The preferred host is registered with the registration function set to “conditionally receive.”
Note If all registered hosts have the registration function set to “conditionally receive,” then the preferred host receives the RLIR frames.
You can specify only one RLIR preferred host per VSAN. By default, the switch sends RLIR frames to one of the hosts in the VSAN with the register function set to “conditionally receive” if no hosts have the register function set to “always receive.”
To specify the RLIR preferred host for a VSAN, follow these steps:
Step 1
Step 2
Step 3 switch# config terminal switch(config)#
Enters configuration mode.
switch(config)# rlir preferred-cond fcid 0x772c00 vsan 5
Specifies FC ID 0x772c00 as the RLIR preferred host in VSAN 5. (FC ID 0x772c00 is used here as an example.) switch(config)# no rlir preferred-cond fcid 0x654321 vsan 2
(Optional) Removes FC ID 0x772c00 as the RLIR preferred host for VSAN 5.
To display the RLIR preferred host configuration, use the show rlir erl command.
switch# show rlir erl
Established Registration List for VSAN: 5
----------------------------------------------
FC-ID LIRR FORMAT REGISTERED FOR
----------------------------------------------
0x772c00 0x18 conditional receive(*)
0x779600 0x18 conditional receive
0x779700 0x18 conditional receive
0x779800 0x18 conditional receive
Total number of entries = 4
(*) - Denotes the preferred host
272
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Configuring FICON
Displaying RLIR Information
Displaying RLIR Information
The show rlir statistics command displays the complete statistics of LIRR, RLIR, and DRLIR frames. It lists the number of frames received, sent, and rejected. Specify the VSAN ID to obtain VSAN statistics for a specific VSAN. If you do not specify the VSAN ID, then the statistics are shown for all active VSANs (see
Examples
Displays RLIR Statistics for All VSANs, on page 273
and
Displays RLIR Statistics for a Specified
Displays RLIR Statistics for All VSANs switch# show rlir statistics
Statistics for VSAN: 1
------------------------
Number of LIRR received
Number of LIRR ACC sent
Number of LIRR RJT sent
Number of RLIR sent
= 0
= 0
= 0
= 0
Number of RLIR ACC received = 0
Number of RLIR RJT received = 0
Number of DRLIR received = 0
Number of DRLIR ACC sent
Number of DRLIR RJT sent
= 0
= 0
Number of DRLIR sent = 0
Number of DRLIR ACC received = 0
Number of DRLIR RJT received = 0
Statistics for VSAN: 100
-------------------------
Number of LIRR received
Number of LIRR ACC sent
Number of LIRR RJT sent
= 26
= 26
= 0
Number of RLIR sent = 815
Number of RLIR ACC received = 815
Number of RLIR RJT received = 0
Number of DRLIR received = 417
Number of DRLIR ACC sent = 417
Number of DRLIR RJT sent
Number of DRLIR sent
= 0
= 914
Number of DRLIR ACC received = 828
Number of DRLIR RJT received = 0
Displays RLIR Statistics for a Specified VSAN switch# show rlir statistics vsan 4
Statistics for VSAN: 4
-------------------------
Number of LIRR received
Number of LIRR ACC sent
Number of LIRR RJT sent
= 0
= 0
= 0
Number of RLIR sent = 0
Number of RLIR ACC received = 0
Number of RLIR RJT received = 0
Number of DRLIR received
Number of DRLIR ACC sent
= 0
= 0
Number of DRLIR RJT sent
Number of DRLIR sent
= 0
= 0
Number of DRLIR ACC received = 0
Number of DRLIR RJT received = 0
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
273
Configuring FICON
Displaying RLIR Information
The show rlir erl command shows the list of Nx ports that are registered to receive the RLIRs with
Displays All ERLs, on page 274
and
Displays ERLs for the Specified VSAN, on page 274 ).
Displays All ERLs switch# show rlir erl
Established Registration List for VSAN: 2
----------------------------------------------
FC-ID LIRR FORMAT REGISTERED FOR
----------------------------------------------
0x0b0200 0x18
Total number of entries = 1 always receive
Established Registration List for VSAN: 100
----------------------------------------------
FC-ID LIRR FORMAT REGISTERED FOR
----------------------------------------------
0x0b0500 0x18 conditional receive
0x0b0600 0x18 conditional receive
Total number of entries = 2
In
Displays All ERLs, on page 274 , if the Registered For column states that an FC ID is conditional
receive, the source port is registered as a valid recipient of subsequent RLIRs. This source port is selected as an RLIR recipient only if no other ERL recipient is selected.
In
Displays All ERLs, on page 274
, if the Registered For column states that an FC ID is always receive, the source port is registered as a valid recipient of subsequent RLIRs. This source port is always selected as an LIR recipient.
Note If an always receive RLIR is not registered for any N port or if the delivery of an RLIR fails for one of those ports, then the RLIR is sent to a port registered to conditional receive RLIRs.
Displays ERLs for the Specified VSAN switch# show rlir erl vsan 100
Established Registration List for VSAN: 100
----------------------------------------------
FC-ID LIRR FORMAT REGISTERED FOR
----------------------------------------------
0x0b0500
0x0b0600
0x18
0x18
Total number of entries = 2 conditional receive conditional receive
Note In
Displays the LIR History, on page 275
, through
time stamp. If the host time stamp is not available, only the switch time stamp is printed.
274
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Configuring FICON
Displaying RLIR Information
Displays the LIR History switch# show rlir history
Link incident history
----------------------------------------------------------------------------
*Host Time Stamp
Switch Time Stamp Port Interface Link Incident
----------------------------------------------------------------------------
*Sun Nov 30 21:47:28 2003
Sun Nov 30 13:47:55 2003
*Sun Nov 30 22:00:47 2003
2 fc1/2 Implicit Incident
2 fc1/2 NOS Received Sun Nov 30 14:01:14 2003
*Sun Nov 30 22:00:55 2003
Sun Nov 30 14:01:22 2003
*Mon Dec 1 20:14:26 2003
Mon Dec 1 12:14:53 2003
2
4 fc1/2 fc1/4
Implicit Incident
Implicit Incident
*Mon Dec 1 20:14:26 2003
Mon Dec 1 12:14:53 2003
*Thu Dec 4 04:43:32 2003
Wed Dec 3 20:43:59 2003
*Thu Dec 4 04:43:41 2003
Wed Dec 3 20:44:08 2003
*Thu Dec 4 04:46:53 2003
Wed Dec 3 20:47:20 2003
*Thu Dec 4 04:47:05 2003
Wed Dec 3 20:47:32 2003
*Thu Dec 4 04:48:07 2003
Wed Dec 3 20:48:34 2003
*Thu Dec 4 04:48:39 2003
Wed Dec 3 20:49:06 2003
*Thu Dec 4 05:02:20 2003
Wed Dec 3 21:02:47 2003
...
4
2
2
2
2
2
2
2 fc1/4 fc1/2 fc1/2 fc1/2 fc1/2 fc1/2 fc1/2 fc1/2
Implicit Incident
NOS Received
Implicit Incident
NOS Received
Implicit Incident
NOS Received
Implicit Incident
NOS Received
Displays Recent LIRs for a Specified Interface switch# show rlir recent interface fc1/1-4
Recent link incident records
-------------------------------------------------------------------------------
Host Time Stamp Switch Time Stamp Port Intf Link Incident
-------------------------------------------------------------------------------
Thu Dec 4 05:02:29 2003 Wed Dec 3 21:02:56 2003 2 fc1/2 Implicit Incident
Thu Dec 4 05:02:54 2003 Wed Dec 3 21:03:21 2003 4 fc1/4 Implicit Incident
Displays Recent LIRs for a Specified Port Number switch# show rlir recent portnumber 1-4
Recent link incident records
--------------------------------------------------------------------------------
Host Time Stamp Switch Time Stamp Port Intf Link Incident
--------------------------------------------------------------------------------
Thu Dec 4 05:02:29 2003 Wed Dec 3 21:02:56 2003 2 fc1/2 Implicit Incident
Thu Dec 4 05:02:54 2003 Wed Dec 3 21:03:21 2003 4 fc1/4 Implicit Incident
As of Cisco SAN-OS Release 3.0(3), the show rlir history command output includes remote link incidents that are received as DRLIRs from other switches. RLIRs are generated as a result of DRLIRs
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
275
Configuring FICON
Clearing RLIR Information as in previous Cisco NX-OS releases (see
Displays the LIR History as of Cisco SAN-OS Release
).
Displays the LIR History as of Cisco SAN-OS Release 3.0(3) switch# show rlir history
Link incident history
----------------------------------------------------------------------------------------------------------------
Host Time Stamp Switch Time Stamp VSAN Domain Port Intf Link
Incident Loc/Rem
----------------------------------------------------------------------------------------------------------------
**** 0x0b fc1/12 Loss Sep 20 12:42:44 2006 of sig/sync LOC
Sep 20 12:42:44 2006
Reported Successfully to: [0x640001] [0x640201]
Sep 20 12:42:48 2006 Sep 20 12:42:48 2006 of sig/sync LOC
Reported Successfully to: [0x640001] [0x640201]
*** ** **:**:** **** Sep 20 12:42:51 2006
****
****
1001 of sig/sync REM
Reported Successfully to: [0x640001] [0x640201]
Sep 20 12:42:55 2006 Sep 20 12:42:55 2006 **** of sig/sync LOC
Reported Successfully to: None [No Registrations]
*** ** **:**:** **** of sig/sync REM
Sep 20 12:45:56 2006 1001
Reported Successfully to: None [No Registrations]
*** ** **:**:** **** of sig/sync REM
Sep 20 12:45:56 2006 1001
Reported Successfully to: None [No Registrations]
Sep 20 12:52:45 2006 Sep 20 12:52:45 2006 **** of sig/sync LOC
Reported Successfully to: None [No Registrations]
**** - Info not required/unavailable
****
230
****
230
230
****
0x0b
0x12
0x0b
0x12
0x12
0x0b fc1/12
**** fc1/12
****
**** fc1/12
Loss
Loss
Loss
Loss
Loss
Loss
Clearing RLIR Information
Use the clear rlir statistics command to clear all existing statistics for a specified VSAN.
switch# clear rlir statistics vsan 1
Use the clear rlir history command to clear the RLIR history where all link incident records are logged for all interfaces.
switch# clear rlir history
Use the clear rlir recent interface command to clear the most recent RLIR information for a specified interface.
switch# clear rlir recent interface fc 1/2
Use the clear rlir recent portnumber command to clear the most recent RLIR information for a specified port number.
276
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Configuring FICON
FICON Configuration Files switch# clear rlir recent portnumber 16
FICON Configuration Files
You can save up to 16 FICON configuration files on each FICON-enabled VSAN (in persistent storage). The file format is proprietary to IBM. These files can be read and written by IBM hosts using the in-band CUP protocol. Additionally, you can use the Cisco MDS CLI to operate on these FICON configuration files.
Note Multiple FICON configuration files with the same name can exist in the same switch, provided they reside in different VSANs. For example, you can create a configuration file named XYZ in both VSAN 1 and VSAN
3.
When you enable the FICON feature in a VSAN, the switches always use the startup FICON configuration file, called IPL. This file is created with a default configuration as soon as FICON is enabled in a VSAN.
Caution When FICON is disabled on a VSAN, all the FICON configuration files are irretrievably lost.
FICON configuration files contain the following configuration for each implemented port address:
• Block
• Prohibit mask
• Port address name
Note Normal configuration files used by Cisco MDS switches include FICON-enabled attributes for a VSAN, port number mapping for PortChannels and FCIP interfaces, port number to port address mapping, port and trunk allowed VSAN configuration for ports, in-order guarantee, static domain ID configuration, and fabric binding configuration.
Refer to the Cisco MDS 9000 Family NX-OS Fundamentals Configuration Guide for details on the normal configuration files used by Cisco MDS switches.
This section includes the following topics:
About FICON Configuration Files
Only one user can access the configuration file at any given time:
• If this file is being accessed by user 1, user 2 cannot access this file.
• If user 2 does attempt to access this file, an error is issued to user 2.
• If user 1 is inactive for more than 15 seconds, the file is automatically closed and available for use by any other permitted user.
FICON configuration files can be accessed by any host, SNMP, or CLI user who is permitted to access the switch. The locking mechanism in the Cisco NX-OS software restricts access to one user at a time per file.
This lock applies to newly created files and previously saved files. Before accessing any file, you must lock
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
277
Configuring FICON
Applying the Saved Configuration Files to the Running Configuration the file and obtain the file key. A new file key is used by the locking mechanism for each lock request. The key is discarded when the lock timeout of 15 seconds expires. The lock timeout value cannot be changed.
Applying the Saved Configuration Files to the Running Configuration
You can apply the configuration from the saved files to the running configuration using the ficon vsan number
apply file filename command.
switch# ficon vsan 2 apply file SampleFile
Editing FICON Configuration Files
The configuration file submode allows you to create and edit FICON configuration files. If a specified file does not exist, it is created. Up to 16 files can be saved. Each file name is restricted to eight alphanumeric characters.
To edit the contents of a specified FICON configuration file, follow these steps:
Step 1
Step 2
Step 3
Step 4
Step 5
Step 6
Step 7 switch# config t switch(config)#
Enters configuration mode.
switch(config)# ficon vsan 2 switch(config-ficon)#
Enables FICON on VSAN 2.
switch(config-ficon)# file IplFile1 switch(config-ficon-file)#
Accesses the FICON configuration file called IplFile1 for VSAN 2. If this file does not exist, it is created.
Note All FICON file names are restricted to eight alphanumeric characters.
switch(config-ficon)# no file IplFileA
(Optional) Deletes a previously created FICON configuration file.
switch(config-ficon-file)# portaddress 3 switch(config-ficon-file-portaddr)#
Enters the submode for port address 3 to edit the contents of the configuration file named IplFile1.
Note The running configuration is not applied to the current configuration. The configuration is only applied when the ficon vsan number apply file filename command is issued.
switch(config-ficon-file-portaddr)# prohibit portaddress 5
Edits the content of the configuration file named IplFile1 by prohibiting port address 5 from accessing port address 3.
switch(config-ficon-file-portaddr)# block
278
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Configuring FICON
Displaying FICON Configuration Files
Step 8
Edits the content of the configuration file named IplFile1 by blocking a range of port addresses and retaining them in the operationally down state.
switch(config-ficon-file-portaddr)# name P3
Edits the content of the configuration file named IplFile1 by assigning the name P3 to port address 3. If the name did not exist, it is created. If it existed, it is overwritten.
Displaying FICON Configuration Files
Use the show ficon vsan vsan-id file all command to display the contents of all FICON configuration files.
switch# show ficon vsan 2 file all
File IPL is locked
FICON configuration file IPLFILEA in vsan 2
Description:
Port address 0(0)
Port name is
Port is not blocked
Prohibited port addresses are 250-253,255(0xfa-0xfd,0xff)
Port address 1(0x1)
Port name is
Port is not blocked
Prohibited port addresses are 250-253,255(0xfa-0xfd,0xff)
Port address 2(0x2)
Port name is
Port is not blocked
Prohibited port addresses are 250-253,255(0xfa-0xfd,0xff)
Port address 3(0x3)
Port name is P3
Port is blocked
Prohibited port addresses are 5,250-253,255(0x5,0xfa-0xfd,0xff)
..
Use the show ficon vsan vsan-id file name command to display the contents of a specific FICON configuration file.
switch# show ficon vsan 2 file name IPLfilea
FICON configuration file IPLFILEA in vsan 2
Description:
Port address 0(0)
Port name is
Port is not blocked
Prohibited port addresses are 250-253,255(0xfa-0xfd,0xff)
Port address 1(0x1)
Port name is
Port is not blocked
Prohibited port addresses are 250-253,255(0xfa-0xfd,0xff)
Port address 2(0x2)
Port name is
Port is not blocked
Prohibited port addresses are 250-253,255(0xfa-0xfd,0xff)
Port address 3(0x3)
Port name is P3
Port is blocked
Prohibited port addresses are 5,250-253,255(0x5,0xfa-0xfd,0xff)
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
279
Configuring FICON
Copying FICON Configuration Files
Use the show ficon vsan vsan-id file name filename portaddress command to display the FICON configuration file information for a specific FICON port.
switch# show ficon vsan 2 file name IPLfilea portaddress 3
FICON configuration file IPLFILEA in vsan 2
Description:
Port address 3(0x3)
Port name is P3
Port is blocked
Prohibited port addresses are 5,250-253,255(0x5,0xfa-0xfd,0xff)
Copying FICON Configuration Files
Use the ficon vsan vsan-id copy file existing-file-name save-as-file-name command in EXEC mode to copy an existing FICON configuration file.
switch# ficon vsan 20 copy file IPL IPL3
You can see the list of existing configuration files by issuing the show ficon vsan vsan-id command.
switch# show ficon vsan 20
Ficon information for VSAN 20
Ficon is online
VSAN is active
Host port control is Enabled
Host offline control is Enabled
User alert mode is Disabled
SNMP port control is Enabled
Host set director timestamp is Enabled
Active=Saved is Enabled
Number of implemented ports are 250
Key Counter is 5
FCID last byte is 0
Date/Time is same as system time (Wed Dec 3 20:10:45.924591 2003)
Device Allegiance not locked
Codepage is us-canada
Saved configuration files
IPL
IPL3
Port Swapping
The FICON port-swapping feature is only provided for maintenance purposes.
The FICON port-swapping feature causes all configurations associated with old-port-number and new port-number to be swapped, including VSAN configurations.
Cisco MDS switches allow port swapping for nonexistent ports as follows:
• Only FICON-specific configurations (prohibit, block, and port address mapping) are swapped.
• No other system configuration is swapped.
• All other system configurations are only maintained for existing ports.
• If you swap a port in a module that has unlimited oversubscription ratios enabled with a port in a module that has limited oversubscription ratios, then you may experience a degradation in bandwidth.
280
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Configuring FICON
About Port Swapping
Tip If you check the Active=Saved check box active equals saved is enabled on any FICON VSAN, then the swapped configuration is automatically saved to startup. Otherwise, you must explicitly save the running configuration immediately after swapping the ports.
Once you swap ports, the switch automatically performs the following actions:
• Shuts down both the old and new ports.
• Swaps the port configuration.
If you attempt to bring the port up, you must explicitly shut down the port to resume traffic.
Note To view the latest FICON information, you must click the Refresh button. See the
Running Configuration, on page 266
.
The ficon swap portnumber command is only associated with the two ports concerned. You must issue this
VSAN-independent command from EXEC mode. Cisco MDS NX-OS checks for duplicate port numbers in a VSAN before performing the port swap.
If you attempt to bring the port up by specifying the ficon swap portnumber old-port-number new-port-number after swap noshut command, you must explicitly issue the no shutdown command to resume traffic.
This section includes the following topics:
About Port Swapping
Be sure to follow these guidelines when using the FICON port swapping feature:
• Port swapping is not supported for logical ports (PortChannels, FCIP links). Neither the old-port-number nor the new-port-number can be a logical port.
• Port swapping is not supported between physical ports that are part of a PortChannel. Neither the old-port-number nor the new-port-number can be a physical port that is part of a PortChannel.
• Before performing a port swap, the Cisco NX-OS software performs a compatibility check. If the two ports have incompatible configurations, the port swap is rejected with an appropriate reason code. For example, if a port with BB_credits as 25 is being swapped with an OSM port for which a maximum of
12 BB_credits is allowed (not a configurable parameter), the port swapping operation is rejected.
• Before performing a port swap, the Cisco NX-OS software performs a compatibility check to verify the extended BB_credits configuration.
• If ports have default values (for some incompatible parameters), then a port swap operation is allowed and the ports retain their default values.
• Port tracking information is not included in port swapping. This information must be configured separately
(refer to the Cisco MDS 9000 Family NX-OS Quality of Service Configuration Guide ).
Note The 32-port module guidelines also apply for port swapping configurations (Refer to the Cisco MDS 9000
Family NX-OS Interfaces Configuration Guide ).
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
281
Configuring FICON
Swapping Ports
Swapping Ports
If there are no duplicate port numbers on the switch, you can swap physical Fibre Channel ports, except the port numbers, by following these steps:
Step 1
Step 2
Step 3
Issue the ficon swap portnumber old-port-number new-port-number command in EXEC mode.
Note The ficon swap portnumber command might fail if more than one interface on the MDS switch has the same port number as the old-port-number or new-port-number specified in the command.
The specified ports are operationally shut down.
Physically swap the front panel port cables between the two ports.
Issue the no shutdown command on each port to enable traffic flow.
Note If you specify the ficon swap portnumber old-port-number new-port-number after swap noshut command, the ports are automatically initialized.
Swapping Ports on the Switch with Duplicate Port Numbers
If there are duplicate port numbers on the switch, you can swap physical Fibre Channel ports, including the port numbers, by following these steps:
Step 1
Step 2
Step 3
Issue the ficon swap interface old-interface new-interface command in EXEC mode.
The specified interfaces are operationally shut down.
Physically swap the front panel port cables between the two ports.
Issue the no shutdown command on each port to enable traffic flow.
Note If you specify the ficon swap interface old-interface new-interface after swap noshut command, the ports are automatically initialized.
FICON Tape Acceleration
The sequential nature of tape devices causes each I/O operation to the tape device over an FCIP link to incur the latency of the FCIP link. Throughput drastically decreases as the round-trip time through the FCIP link increases, leading to longer backup windows. Also, after each I/O operation, the tape device is idle until the next I/O arrives. Starting and stopping of the tape head reduces the lifespan of the tape, except when I/O operations are directed to a virtual tape.
Cisco MDS NX-OS software provides acceleration for the following FICON tape write operations:
• The link between mainframe and native tape drives (both IBM and Sun/STK)
• The back-end link between the VSM (Virtual Storage Management) and tape drive (Sun/STK)
282
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Configuring FICON
FICON Tape Acceleration
FICON tape acceleration over FCIP provides the following advantages:
• Efficiently utilizes the tape device by decreasing idle time
• More sustained throughput as latency increases
• Similar to FCP tape acceleration, and does not conflict with it
Note FICON tape read acceleration over FCIP is supported from Cisco MDS NX-OS Release 5.0(1). For more information refer to the
Configuring FICON Tape Read Acceleration, on page 285
.
Figure 59: Host Directly Accessing IBM/STK (StorageTek) Library, on page 283
through
Accessing Peer-to-Peer VTS (Virtual Tape Server), on page 284
show supported configurations:
Figure 59: Host Directly Accessing IBM/STK (StorageTek) Library
Figure 60: Host Accessing Standalone IBM-VTS (Virtual Tape Server) /STK-VSM (Virtual Shared Memory)
Figure 61: Host Accessing Peer-to-Peer VTS (Virtual Tape Server)
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
283
Configuring FICON Tape Acceleration
Figure 62: Host Accessing Peer-to-Peer VTS (Virtual Tape Server)
Configuring FICON
Note For information about FCIP tape acceleration, refer to the Cisco MDS 9000 Family NX-OS IP Services
Configuration Guide .
Configuring FICON Tape Acceleration
FICON tape acceleration has the following configuration considerations:
• In addition to the normal FICON configuration, FICON tape acceleration must be enabled on both ends of the FCIP interface. If only one end has FICON tape acceleration enabled, acceleration does not occur.
• FICON tape acceleration is enabled on a per VSAN basis.
• FICON tape acceleration cannot function if multiple ISLs are present in the same VSAN (PortChannels or FSPF load balanced).
• You can enable both Fibre Channel write acceleration and FICON tape acceleration on the same FCIP interface.
• Enabling or disabling FICON tape acceleration disrupts traffic on the FCIP interface.
To configure FICON tape acceleration, follow these steps:
Step 1
Step 2
Step 3 switch# config t switch(config)#
Enters configuration mode.
switch(config)# interface fcip 2 switch(config-if)#
Specifies an FCIP interface and enters interface configuration submode.
switch(config-if)# ficon-tape-accelerator vsan 100
This configuration change will disrupt all traffic on the FCIP interface in all
VSANs.
Do you wish to continue? [no] y
284
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Configuring FICON
Configuring FICON Tape Read Acceleration
Step 4
Enables FICON tape acceleration over an FCIP interface.
switch(config-if)# no ficon-tape-accelerator vsan 100
This configuration change will disrupt all traffic on the FCIP interface in all
VSANs.
Do you wish to continue? [no] y
Disables (default) FICON tape acceleration over an FCIP interface.
What to do next
Use the show running-config command to verify the FICON tape acceleration over FCIP configuration.
switch# show running-config | begin "interface fcip" interface fcip2 ficon-tape-accelerator vsan 100 no shutdown
...
Configuring FICON Tape Read Acceleration
All the configuration guidelines and restrictions applicable for FICON tape acceleration are also applicable for FICON tape read acceleration. Both FICON tape acceleration and FICON tape read acceleration can coexist.
To configure FICON tape read acceleration, follow these steps:
Step 1
Step 2
Step 3
Step 4 switch# config t switch(config)#
Enters configuration mode.
switch(config)# interface fcip 2 switch(config-if)#
Specifies an FCIP interface and enters interface configuration submode.
switch(config-if)# ficon-tape-read-accelerator
This configuration change will disrupt all traffic on the FCIP interface in all
VSANs.
Do you wish to continue? [no]
Enables FICON tape read acceleration over an FCIP interface.
switch(config-if)# no ficon-tape-read-accelerator
This configuration change will disrupt all traffic on the FCIP interface in all
VSANs.
Do you wish to continue? [no]
Disables (default) FICON tape read acceleration over an FCIP interface.
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
285
Configuring FICON
Configuring XRC Acceleration
Configuring XRC Acceleration
IBM z/OS Global Mirror eXtended Remote Copy (XRC) is supported on the MSM-18+4 modules. For XRC to function, XRC acceleration must be enabled on the FCIP tunnel interfaces on both ends. XRC acceleration is disabled by default.
To enable XRC acceleration, follow these steps:
Step 1
Step 2
Step 3
Step 4 switch# config t switch(config)#
Enters the configuration mode.
switch(config)# interface fcip 2 switch(config)#
Specifies an FCIP tunnel interface and enters interface configuration submode.
switch(config-if)# ficon-xrc-emulator switch(config)#
Enables XRC acceleration over the FCIP interface.
switch(config-if)# no ficon-xrc-emulator switch(config)#
Disables (default) XRC acceleration over the FCIP tunnel interface.
Note XRC acceleration and FICON tape acceleration cannot be enabled on the same FCIP tunnel interface and cannot exist in the same VSAN.
Moving a FICON VSAN to an Offline State
Issue the ficon vsan vsan-id offline command in EXEC mode to log out all ports in the VSAN that need to be suspended.
Issue the EXEC-level ficon vsan vsan-id online command in EXEC mode to remove the offline condition and to allow ports to log on again.
Note This command can be issued by the host if the host is allowed to do so (see the
Allowing the Host to Move the Switch Offline, on page 263 ).
286
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Configuring FICON
CUP In-Band Management
CUP In-Band Management
The CUP protocol configures access control and provides unified storage management capabilities from a mainframe computer. Cisco MDS 9000 FICON-enabled switches are fully IBM CUP standard compliant for in-band management using the IBM S/A OS/390 I/O operations console.
Note The CUP specification is proprietary to IBM.
CUP is supported by switches and directors in the Cisco MDS 9000 Family. The CUP function allows the mainframe to manage the Cisco MDS switches.
Host communication includes control functions such as blocking and unblocking ports, as well as monitoring and error reporting functions.
This section includes the following topics:
Placing CUPs in a Zone
To place the CUP in a zone, follow these steps:
Step 1
Step 2
Step 3
Set the default zone to permit for the required VSAN.
switch# config terminal switch(config)# zone default-zone permit vsan 20
Issue the show fcns database command for the required VSAN and obtain the required FICON CUP WWN.
switch# show fcns database vsan 20
VSAN 20:
--------------------------------------------------------------------------
FCID TYPE PWWN (VENDOR) FC4-TYPE:FEATURE
--------------------------------------------------------------------------
0x0d0d00 N 50:06:04:88:00:1d:60:83 (EMC) FICON:CU
0x0dfe00 N 25:00:00:0c:ce:5c:5e:c2
(Cisco)
0x200400
0x200800
N
N
FICON:CUP
50:05:07:63:00:c2:82:d3 (IBM)
50:05:07:64:01:40:15:0f (IBM)
0x20fe00 N 20:00:00:0c:30:ac:9e:82 (Cisco)
Total number of entries = 5 scsi-fcp FICON:CU f..
FICON:CH
FICON:CUP
Note If more than one FICON:CUP WWN exists in this fabric, be sure to add all the FICON:CUP WWN PWWNs to the required zone. The previous sample output displays multiple FICON:CUP occurrences to indicate a cascade configuration.
Add the identified FICON:CUP WWN to the zone database.
switch(config)# zone name Zone1 vsan 20 switch(config-zone)# member pwwn 25:00:00:0c:ce:5c:5e:c2
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
287
Configuring FICON
Displaying Control Unit Information
Displaying Control Unit Information
Displays Control Unit Information, on page 288
displays configured control device information.
Displays Control Unit Information switch# show ficon control-device sb3
Control Unit Image:0x80b9c2c
VSAN:20 CU:0x20fe00 CUI:0 CUD:0 CURLP:(nil)
ASYNC LP:(nil) MODE:1 STATE:1 CQ LEN:0 MAX:0
PRIMARY LP: VSAN:0 CH:0x0 CHI:0 CU:0x0 CUI:0
ALTERNATE LP: VSAN:0 CH:0x0 CHI:0 CU:0x0 CUI:0
Logical Path:0x80b9fb4
VSAN:20 CH:0x200600 CHI:15 CU:0x20fe00 CUI:0 STATE:1 FLAGS:0x1
LINK: OH:0x0 OC:0x0 IH:0x0 IC:0x0
DEV: OH:0x0 OC:0x0 IH:0x0 IC:0x0
SENSE: 00 00 00 00 00 00 00 46
30 20 00 00 00 00 00 00
00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00
IUI:0x0 DHF:0x0 CCW:0x0 TOKEN:0x0 PCCW:0x0 FCCW:0x0 PTOKEN:0x0 FTOKEN:0x0
CMD:0x0 CCW_FLAGS:0x0 CCW_COUNT:0 CMD_FLAGS:0x0 PRIO:0x0 DATA_COUNT:0
STATUS:0x0 FLAGS:0x0 PARAM:0x0 QTP:0x0 DTP:0x0
CQ LEN:0 MAX:0 DESTATUS:0x0
Displaying FICON Information
This section includes the following topics:
Receiving FICON Alerts
In
you will receive an alert to indicate any changes in the FICON configuration.
Displays Configured FICON Information switch# show ficon
Ficon information for VSAN 20
Ficon is online
VSAN is active
Host port control is Enabled
Host offline control is Enabled
User alert mode is Enabled
SNMP port control is Enabled
Host set director timestamp is Enabled
Active=Saved is Disabled
Number of implemented ports are 250
Key Counter is 73723
FCID last byte is 0
Date/Time is set by host to Sun Jun 26 00:04:06.991999 1904
Device allegiance is locked by Host
Codepage is us-canada
Saved configuration files
288
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Configuring FICON
Displaying FICON Port Address Information
IPL
_TSIRN00
Displaying FICON Port Address Information
Examples
Displays Port Address Information, on page 289
to
Displays Port Address Counter Information, on page 290
display FICON Port Address information.
Displays Port Address Information switch# show ficon vsan 2 portaddress
Port Address 1 is not installed in vsan 2
Port number is 1, Interface is fc1/1
Port name is
Port is not admin blocked
Prohibited port addresses are 0,241-253,255
Port Address 2 is not installed in vsan 2
Port number is 2, Interface is fc1/2
Port name is
Port is not admin blocked
Prohibited port addresses are 0,241-253,255
...
Port Address 249 is not installed in vsan 2
Port name is
Port is not admin blocked
Prohibited port addresses are 0,241-253,255
Port Address 250 is not installed in vsan 2
Port name is
Port is not admin blocked
Prohibited port addresses are 0,241-253,255
Displays the Available Port Numbers switch# show ficon first-available port-number
Port number 129(0x81) is available
In
Displays Port Address Information in a Brief Format, on page 289 , the interface column is populated
with the corresponding interface if the port number is installed. If the port number is uninstalled, this space remains blank and indicates an unbound port number. For example, 56 is an unbound port number in
Displays Port Address Information in a Brief Format, on page 289
.
Displays Port Address Information in a Brief Format switch# show ficon vsan 2 portaddress 50-55 brief
-------------------------------------------------------------------------------
Port Port
Address Number
Interface Admin
Blocked
Status Oper
Mode
FCID
-------------------------------------------------------------------------------
50 50 fc2/18 on fcotAbsent ---
51 51 fc2/19 off fcotAbsent ---
52
53
54
52
53
54 fc2/20 fc2/21 fc2/22 off off off fcotAbsent fcotAbsent notConnected
--
--
--
--
--
--
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
289
Configuring FICON
Displaying FICON Configuration File Information
55
56
55
56 fc2/23 off off up up
FL
FL
0xea0000
0xea0000
Displays Port Address Counter Information, on page 290
displays the counters in FICON version format 1 (32-bit format)
Displays Port Address Counter Information switch# show ficon vsan 20 portaddress 8 counters
Port Address 8(0x8) is up in vsan 20
Port number is 8(0x8), Interface is fc1/8
Version presented 1, Counter size 32b
242811 frames input, 9912794 words
484 class-2 frames, 242302 class-3 frames
0 link control frames, 0 multicast frames
0 disparity errors inside frames
0 disparity errors outside frames
0 frames too big, 0 frames too small
0 crc errors, 0 eof errors
0 invalid ordered sets
0 frames discarded c3
0 address id errors
116620 frames output, 10609188 words
0 frame pacing time
0 link failures
0 loss of sync
0 loss of signal
0 primitive seq prot errors
0 invalid transmission words
1 lrr input, 0 ols input, 5 ols output
0 error summary
Displaying FICON Configuration File Information
Examples
Displays the Contents of the Specified FICON Configuration File, on page 290
to
Specified Port Addresses for a FICON Configuration File, on page 291
display FICON configuration file information.
Displays the Contents of the Specified FICON Configuration File switch# show ficon vsan 3 file IPL
FICON configuration file IPL
Port address 1 in vsan 3
Port name is
Port is not blocked
Prohibited port addresses are 0,81-253,255
Port address 2
Port name is
Port is not blocked
Prohibited port addresses are 0,81-253,255
Port address 3
Port name is
Port is not blocked
Prohibited port addresses are 0,81-253,255
Port address 4
Port name is
290
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Configuring FICON
Displaying FICON Configuration File Information
Port is not blocked
Prohibited port addresses are 0,81-253,255
...
Port address 80
Port name is
Port is not blocked
Prohibited port addresses are 0,81-253,255
Port address 254
Port name is
Port is not blocked
Prohibited port addresses are 0,81-253,255
Displays All FICON Configuration Files switch# show ficon vsan 2
Ficon information for VSAN 2
Ficon is enabled
VSAN is active
Host control is Enabled
Host offline control is Enabled
Clock alert mode is Disabled
User alert mode is Disabled
SNMP control is Disabled
Active=Saved is Disabled
Number of implemented ports are 250
Key Counter is 9
FCID last byte is 0
Date/Time is same as system time(Sun Dec 14 01:26:30.273402 1980)
Device Allegiance not locked
Codepage is us-canada
Saved configuration files
IPL
IPLFILE1
Displays the Specified Port Addresses for a FICON Configuration File switch# show ficon vsan 2 file iplfile1 portaddress 1-7
FICON configuration file IPLFILE1 in vsan 2
Port address 1
Port name is
Port is not blocked
Prohibited port addresses are 0,241-253,255
Port address 2
Port name is
Port is not blocked
Prohibited port addresses are 0,241-253,255
Port address 3
Port name is P3
Port is not blocked
Prohibited port addresses are 0,241-253,255
...
Port address 7
Port name is
Port is not blocked
Prohibited port addresses are 0,241-253,255
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
291
Configuring FICON
Displaying the Configured FICON State
Displaying the Configured FICON State
If FICON is enabled on a VSAN, you can display the port address information for that VSAN (see
Displays the Specified Port Address When FICON Is Enabled, on page 292
).
Displays the Specified Port Address When FICON Is Enabled switch# show ficon vsan 2 portaddress 55
Port Address 55 is not installed in vsan 2
Port number is 55, Interface is fc2/23
Port name is
Port is not admin blocked
Prohibited port addresses are 0,241-253,255
Admin port mode is FL
Port mode is FL, FCID is 0xea0000
Displaying a Port Administrative State
Examples
Displays an Administratively Unblocked Port , on page 292
to
display the administrative state of a FICON port. If the port is blocked, the show
ficon vsan number portaddress number command displays the blocked state of the port. If a specific port is prohibited, this command also displays the specifically prohibited port (3) along with the ports that are prohibited by default (0, 241 to 253, and 255). If a name is assigned, that name is also displayed.
Displays an Administratively Unblocked Port switch# show ficon vsan 2 portaddress 2
Port Address 2(0x2) is not installed in vsan 2
Port number is 2(0x2), Interface is fc1/2
Port name is
Port is not admin blocked
Prohibited port addresses are 0,241-253,255(0,0xf1-0xfd,0xff)
Admin port mode is auto
Peer is Unknown
Displays an Administratively Blocked Port switch# show ficon vsan 2 portaddress 1
Port Address 2(0x2) is not installed in vsan 2
Port number is 2(0x2), Interface is fc1/2
Port name is SampleName
Port is admin blocked
Prohibited port addresses are 0,241-253,255(0,0xf1-0xfd,0xff)
Admin port mode is auto
Peer is Unknown
292
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Configuring FICON
Displaying Buffer Information
Displaying Buffer Information
In
32-bit value maintained by Cisco MDS switches. This value is incremented when any port changes state in that VSAN. The key counter (a 32-bit value) is incremented when a FICON-related configuration is changed.
Host programs can increment this value at the start of the channel program and then perform operations on multiple ports. The director history buffer keeps a log of which port address configuration was changed for each key-counter value.
The director history buffer provides a mechanism to determine the change in the port state from the previous time when a value was contained in the key counter.
Displays the History Buffer for the Specified VSAN
74570
74571
74572
74573
74574
74575
74576
74577
74578
74579
74580
74581
74582
74583
74584
74585
74586
74587
74560
74561
74562
74563
74564
74565
74566
74567
74568
74569 switch# show ficon vsan 20 director-history
Director History Buffer for vsan 20
---------------------------------------------
Key Counter Ports Address
Changed
---------------------------------------------
74556 43
74557 44
74558
74559
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
1-3,5,10,12,14-16,34-40,43-45,47-54,56-57,59-64
3,5
64
1-3,10,12,14-16,34-40,43-45,47-54,56-57,59-64
1
2
3
Viewing the History Buffer
In the directory history buffer, the Key Counter column displays the 32-bit value maintained by Cisco MDS switches. This value is incremented when any port changes state in that VSAN. The key counter (a 32-bit
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
293
Configuring FICON
Displaying FICON Information in the Running Configuration value) is incremented when a FICON-related configuration is changed. Host programs can increment this value at the start of the channel program and then perform operations on multiple ports. The director history buffer keeps a log of which port address configuration was changed for each key-counter value.
The director history buffer provides a mechanism to determine the change in the port state from the previous time when a value was contained in the key counter.
Displaying FICON Information in the Running Configuration
Displays the Running Configuration Information, on page 294
displays the FICON-related information in the running configuration.
Displays the Running Configuration Information switch# show running-config
Building Configuration ...
in-order-guarantee vsan database vsan 11 name “FICON11” loadbalancing src-dst-id vsan 75 name “FICON75” loadbalancing src-dst-id fcdomain domain 11 static vsan 11 fcdomain domain 119 static vsan 75 fcdroplatency network 100 vsan 11 fcdroplatency network 500 vsan 75 feature fabric-binding fabric-binding database vsan 11 swwn 20:00:00:0d:ec:01:20:c0 domain 10 fabric-binding database vsan 75 swwn 20:00:00:0d:ec:00:d6:40 domain 117 fabric-binding activate vsan 11 fabric-binding activate vsan 75 ficon vsan 75 interface port-channel 1 ficon portnumber 0x80 switchport mode E snmp-server user mblair network-admin auth md5 0x688fa3a2e51ba5538211606e59ac292
7 priv 0x688fa3a2e51ba5538211606e59ac2927 localizedkey snmp-server user wwilson network-admin auth md5 0x688fa3a2e51ba5538211606e59ac29
27 priv 0x688fa3a2e51ba5538211606e59ac2927 localizedkey snmp-server host 171.71.187.101 traps version 2c public udp-port 1163 snmp-server host 172.18.2.247 traps version 2c public udp-port 2162 vsan database vsan 75 interface fc1/1
...
interface mgmt0 ip address 172.18.47.39 255.255.255.128
switchport speed 100 switchport duplex full no system health ficon vsan 75 file IPL
Displaying FICON Information in the Startup Configuration
Displays the Startup Configuration, on page 295
displays the FICON-related information in the startup configuration.
294
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Configuring FICON
Displaying FICON-Related Log Information
Displays the Startup Configuration switch# show startup-config
...
ficon vsan 2 file IPL
Displays the Startup Configuration Status, on page 295
displays the switch response to an implicitly-issued copy running start command. In this case, only a binary configuration is saved until you explicitly issue the copy running start command again (see
Table 24: Saving the Active FICON and Switch Configuration , on page 266
)
Displays the Startup Configuration Status switch# show startup-config
No ASCII config available since configuration was last saved internally on account of 'active=saved' mode.
Please perform an explicit 'copy running startup` to get ASCII configuration
Displaying FICON-Related Log Information
Displays Logging Levels for the FICON Feature, on page 295
and
Displays FICON-Related Log File Contents, on page 295
display the logging information for FICON-related configurations.
Displays Logging Levels for the FICON Feature switch# show logging level ficon
Facility
-------ficon
Default Severity
----------------
2
0(emergencies)
3(errors)
6(information)
1(alerts)
4(warnings)
7(debugging)
Current Session Severity
------------------------
2
2(critical)
5(notifications)
Displays FICON-Related Log File Contents switch# show logging logfile
...
2004 Feb 25 15:38:50 vegas6 %PORT-5-IF_UP: %$VSAN 75: 2004 Wed Feb 25 13:22:04.
131183%$ Interface fc1/8 is up in mode F
2004 Feb 25 15:38:50 vegas6 %PORT-5-IF_UP: %$VSAN 75: 2004 Wed Feb 25 13:22:04.
131217%$ Interface fc1/9 is up in mode F
...
2004 Feb 25 15:39:09 vegas6 %PORT-5-IF_TRUNK_UP: %$VSAN 75: 2004 Wed Feb 25 13:
22:23.131121%$ Interface fc2/1, vsan 75 is up
2004 Feb 25 15:39:09 vegas6 %PORT-5-IF_TRUNK_UP: %$VSAN 75: 2004 Wed Feb 25 13:
22:23.131121%$ Interface fc2/2, vsan 75 is up
2004 Feb 25 15:39:09 vegas6 %PORT-5-IF_TRUNK_UP: %$VSAN 75: 2004 Wed Feb 25 13:
...
2004 Feb 25 23:22:36 vegas6 %PORT-5-IF_UP: %$VSAN 75: 2004 Wed Feb 25 21:05:42.
99916%$ Interface fc3/6 is up in mode F
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
295
Configuring FICON
Default Settings
2004 Feb 25 23:22:37 vegas6 %PORT-5-IF_UP: %$VSAN 75: 2004 Wed Feb 25 21:05:43.
...
Default Settings
Table 25: Default FICON Settings , on page 296
lists the default settings for FICON features.
Table 25: Default FICON Settings
Parameters
FICON feature
Default
Disabled.
Port numbers
FC ID last byte value
Same as port addresses.
0 (zero).
EBCDIC format option US-Canada.
Switch offline state Hosts are allowed to move the switch to an offline state.
Mainframe users
Clock in each VSAN
Host clock control
SNMP users
Port address
Prohibited ports
Allowed to configure FICON parameters on Cisco MDS switches.
Same as the switch hardware clock.
Allows host to set the clock on this switch.
Configure FICON parameters.
Not blocked
Ports90–253 and 255 for the Cisco MDS 9200 Series switches.
Ports250–253 and 255 for the Cisco MDS 9500 Series switches.
296
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
C H A P T E R
11
Advanced Features and Concepts
This chapter describes the advanced features provided in switches in the Cisco MDS 9000 Family. It includes the following sections:
•
Common Information Model, on page 297
•
Fibre Channel Time-Out Values, on page 297
•
Organizationally Unique Identifiers, on page 302
•
•
FC ID Allocation for HBAs, on page 305
•
Switch Interoperability, on page 307
•
Common Information Model
Common Information Model (CIM) is an object-oriented information model that extends the existing standards for describing management information in a network/enterprise environment.
CIM messages are independent of platform and implementation because they are encoded in N Extensible
Markup Language (XML). CIM consists of a specification and a schema. The specification defines the syntax and rules for describing management data and integrating with other management models. The schema provides the actual model descriptions for systems, applications, networks, and devices.
For more information about CIM, refer to the specification available through the Distributed Management
Task Force (DMTF) website at the following URL: http://www.dmtf.org/
Note The CIM Functionality and SMI-S is now supported with Cisco Prime Data Center Network Manager (DCNM).
Please refer to “Cisco Prime DCNM Installation Guide” and “SMI-S and Web Services Programming Guide,
Cisco DCNM for SAN.
Fibre Channel Time-Out Values
You can modify Fibre Channel protocol related timer values for the switch by configuring the following time-out values (TOVs):
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
297
Advanced Features and Concepts
Timer Configuration Across All VSANs
• Distributed services TOV (D_S_TOV)—The valid range is from 5,000 to 10,000 milliseconds. The default is 5,000 milliseconds.
• Error detect TOV (E_D_TOV)—The valid range is from 1,000 to 4,000 milliseconds. The default is
2,000 milliseconds. This value is matched with the other end during port initialization.
• Resource allocation TOV (R_A_TOV)—The valid range is from 5,000 to 10,000 milliseconds. The default is 10,000 milliseconds. This value is matched with the other end during port initialization.
Note The fabric stability TOV (F_S_TOV) constant cannot be configured.
This section includes the following topics:
Timer Configuration Across All VSANs
You can modify Fibre Channel protocol related timer values for the switch.
Caution The D_S_TOV, E_D_TOV, and R_A_ TOV values cannot be globally changed unless all VSANs in the switch are suspended.
Note If a VSAN is not specified when you change the timer value, the changed value is applied to all VSANs in the switch.
To configure Fibre Channel timers across all VSANs, follow these steps:
Step 1
Step 2 switch# config terminal switch(config)
Enters configuration mode.
switch(config)# fctimer R_A_TOV 6000
Configures the R_A_TOV value for all VSANs to be 6000 msec. This type of configuration is not permitted unless all
VSANs are suspended.
Timer Configuration Per-VSAN
You can also issue the fctimer for a specified VSAN to configure different TOV values for VSANs with special links like FC or IP tunnels. You can configure different E_D_TOV, R_A_TOV, and D_S_TOV values for individual VSANs. Active VSANs are suspended and activated when their timer values are changed.
298
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Advanced Features and Concepts
About fctimer Distribution
Caution You cannot perform a nondisruptive downgrade to any earlier version that does not support per-VSAN FC timers.
Note This configuration must be propagated to all switches in the fabric—be sure to configure the same value in all switches in the fabric.
If a switch is downgraded to Cisco MDS SAN-OS Release 1.2 or 1.1 after the timer is configured for a VSAN, an error message is issued to warn against strict incompatibilities. Refer to the Cisco MDS 9000 Family
Troubleshooting Guide .
To configure per-VSAN Fiber Channel timers, follow these steps:
Step 1
Step 2 switch# config terminal switch(config)#
Enters configuration mode.
switch(config)# fctimer D_S_TOV 6000 vsan 2
Warning: The vsan will be temporarily suspended when updating the timer value This configuration would impact whole fabric. Do you want to continue? (y/n) y
Since this configuration is not propagated to other switches, please configure the same value in all the switches
Configures the D_S_TOV value to be 6000 msec for VSAN 2. Suspends the VSAN temporarily. You have the option to end this command, if required.
About fctimer Distribution
You can enable per-VSAN fctimer fabric distribution for all Cisco MDS switches in the fabric. When you perform fctimer configurations, and distribution is enabled, that configuration is distributed to all the switches in the fabric.
You automatically acquire a fabric-wide lock when you issue the first configuration command after you enabled distribution in a switch. The fctimer application uses the effective and pending database model to store or commit the commands based on your configuration.
Refer to the Cisco MDS 9000 Family NX-OS System Management Configuration Guide for more information on the CFS application.
Enabling fctimer Distribution
To enable or disable fctimer fabric distribution, follow these steps:
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
299
Advanced Features and Concepts
Committing fctimer Changes
Step 1
Step 2
Step 3 switch# config terminal switch(config)#
Enters configuration mode.
switch(config)# fctimer distribute
Enables fctimer configuration distribution to all switches in the fabric. Acquires a fabric lock and stores all future configuration changes in the pending database.
switch(config)# no fctimer distribute
Disables (default) fctimer configuration distribution to all switches in the fabric.
Committing fctimer Changes
When you commit the fctimer configuration changes, the effective database is overwritten by the configuration changes in the pending database and all the switches in the fabric receive the same configuration. When you commit the fctimer configuration changes without implementing the session feature, the fctimer configurations are distributed to all the switches in the physical fabric.
To commit the fctimer configuration changes, follow these steps:
Step 1
Step 2 switch# config terminal switch(config)#
Enters configuration mode.
switch(config)# fctimer commit
Distributes the fctimer configuration changes to all switches in the fabric and releases the lock. Overwrites the effective database with the changes made to the pending database.
Discarding fctimer Changes
After making the configuration changes, you can choose to discard the changes by discarding the changes instead of committing them. In either case, the lock is released.
To discard the fctimer configuration changes, follow these steps:
Step 1
Step 2 switch# config terminal switch(config)#
Enters configuration mode.
switch(config)# fctimer abort
300
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Advanced Features and Concepts
Fabric Lock Override
Discards the fctimer configuration changes in the pending database and releases the fabric lock.
Fabric Lock Override
If you have performed a fctimer fabric task and have forgotten to release the lock by either committing or discarding the changes, an administrator can release the lock from any switch in the fabric. If the administrator performs this task, your changes to the pending database are discarded and the fabric lock is released.
Tip The changes are only available in the volatile directory and are subject to being discarded if the switch is restarted.
To use administrative privileges and release a locked fctimer session, use the clear fctimer session command.
switch# clear fctimer session
Database Merge Guidelines
For information about CFS merge support, refer to the Cisco MDS 9000 Family NX-OS System Management
Configuration Guide .
When merging two fabrics, follow these guidelines:
• Be aware of the following merge conditions:
• The merge protocol is not implemented for distribution of the fctimer values—you must manually merge the fctimer values when a fabric is merged.The per-VSAN fctimer configuration is distributed in the physical fabric.
• The fctimer configuration is only applied to those switches containing the VSAN with a modified fctimer value.
• The global fctimer values are not distributed.
Note The number of pending fctimer configuration operations cannot be more than 15. At that point, you must commit or terminate the pending configurations before performing any more operations.
Displaying Configured fctimer Values
Use the show fctimer command to display the configured fctimer values (see the following examples).
Displays Configured Global TOVs switch# show fctimer
F_S_TOV D_S_TOV E_D_TOV R_A_TOV
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
301
Advanced Features and Concepts
Organizationally Unique Identifiers
----------------------------------------
5000 ms 5000 ms 2000 ms 10000 ms
Note The F_S_TOV constant, though not configured, is displayed in the output of the show fctimer command.
Displays Configured TOVs for a Specified VSAN switch# show fctimer vsan 10 vsan no.
F_S_TOV D_S_TOV E_D_TOV R_A_TOV
-------------------------------------------------
10 5000 ms 5000 ms 3000 ms 10000 ms
Organizationally Unique Identifiers
Organizationally Unique Identifiers (OUIs) are unique 24 bit numbers that identify an organization globally.
OUIs are extended by the organisation they are assigned to, to create 48 bit or 60 bit Extended Unique Identifiers
(EUIs). Cisco obtains OUIs from IEEE and uses them to construct EUIs. These are assigned and burnt in to each system. A system may have one or more EUIs assigned to it. The EUIs are used in various forms such as MAC addresses, WWNs, SNMP identifiers, and so on.
Cisco MDS NX-OS software has an OUI database based on which certain software functionalities are made available. If a new Cisco device with an unrecognized OUI is added to a fabric, there is a possibility that some of these functionalities might be affected. To avoid this issue, the ability to manually add OUIs to the OUI database using the CLI is available.
Guidelines and Limitations
• ISSU—After an upgrade, there may be instances of duplicate OUIs in the default (built-in) and static
(user defined) lists. In such a scenario, we recommend that you compare static OUIs with those in the default list and delete the duplicate static OUIs.
• ISSD—Delete all the configured or static OUIs before performing a downgrade to a release that does not support the wwn oui oui-id command.
For more information on deleting OUIs, see the
Adding and Deleting OUIs, on page 302
section.
Adding and Deleting OUIs
To add an OUI to the OUI database, enter the wwn oui oui-id command in global configuration mode. To delete an OUI from the OUI database, enter the no wwn oui oui-id command in global configuration mode.
.
For detailed information about the wwn oui command, see the Cisco MDS 9000 Family Command Reference
302
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Advanced Features and Concepts
Configuration Examples for Adding and Deleting OUIs
Configuration Examples for Adding and Deleting OUIs
Example: Adding and Deleting OUIs
switch# configure terminal switch(config)# wwn oui 0x10001c switch(config)# no wwn oui 0x10001c switch(config)# end
Example: Displaying OUIs
switch# show wwn oui
OUI Vendor Default/Static
----------------------------------------------------
0x0000fc Cisco
0x00000c Cisco
Static
Default
0x000196 Cisco
0x000197 Cisco
0x0001c7 Cisco
0x0001c9 Cisco
Default
Default
Default
Default
World Wide Names
The world wide name (WWN) in the switch is equivalent to the Ethernet MAC address. As with the MAC address, you must uniquely associate the WWN to a single device. The principal switch selection and the allocation of domain IDs rely on the WWN. The WWN manager, a process-level manager residing on the switch’s supervisor module, assigns WWNs to each switch.
Cisco MDS 9000 Family switches support three network address authority (NAA) address formats (see
26: Standardized NAA WWN Formats , on page 303 ).
Table 26: Standardized NAA WWN Formats
NAA Address
IEEE 48-bit address
IEEE extended
IEEE registered
NAA Type
Type 1 = 0001b
Type 2 = 0010b
Type 5 = 0101b
WWW Format
000 0000 0000b 48-bit MAC address
Locally assigned 48-bit MAC address
IEEE company ID: 24 bits VSID: 36 bits
Caution Changes to the world-wide names should be made by an administrator or individual who is completely familiar with switch operations.
This section includes the following topics:
Displaying WWN Information
Use the show wwn commands to display the status of the WWN configuration. See the following examples:
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
303
Advanced Features and Concepts
Link Initialization WWN Usage
Displays the Status of All WWNs switch# show wwn status
Type 1 WWNs: Configured: 64 Available: 48 (75%) Resvd.: 16
Types 2 & 5 WWNs: Configured: 524288 Available: 450560 (85%) Resvd.: 73728
NKAU & NKCR WWN Blks: Configured: 1760 Available: 1760 (100%)
Alarm Status: Type1: NONE Types 2&5: NONE
Displays Specified Block ID Information switch# show wwn status block-id 51
WWNs in this block: 21:00:ac:16:5e:52:00:03 to 21:ff:ac:16:5e:52:00:03
Num. of WWNs:: Configured: 256 Allocated: 0 Available: 256
Block Allocation Status: FREE
Displays the WWN for a Specific Switch switch# show wwn switch
Switch WWN is 20:00:ac:16:5e:52:00:00
Link Initialization WWN Usage
Exchange Link Protocol (ELP) and Exchange Fabric Protocol (EFP) use WWNs during link initialization.
The usage details differ based on the Cisco NX-OS software release.
Both ELPs and EFPs use the VSAN WWN by default during link initialization. However, the ELP usage changes based on the peer switch’s usage:
• If the peer switch ELP uses the switch WWN, then the local switch also uses the switch WWN.
• If the peer switch ELP uses the VSAN WWN, then the local switch also uses the VSAN WWN.
Note As of Cisco SAN-OS Release 2.0(2b), the ELP is enhanced to be compliant with FC-SW-3.
Configuring a Secondary MAC Address
To allocate secondary MAC addresses, follow these steps:
Step 1
Step 2 switch# config terminal switch(config)#
Enters configuration mode.
switch(config)# wwn secondary-mac 00:99:55:77:55:55 range 64
304
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Advanced Features and Concepts
FC ID Allocation for HBAs
This command CANNOT be undone.
Please enter the BASE MAC ADDRESS again:
00:99:55:77:55:55
Please enter the mac address RANGE again: 64
From now on WWN allocation would be based on new MACs.
Are you sure? (yes/no) no
You entered: no. Secondary MAC NOT programmed
Configures the secondary MAC address. This command cannot be undone.
FC ID Allocation for HBAs
Fibre Channel standards require a unique FC ID to be allocated to an N port attached to a Fx port in any switch. To conserve the number of FC IDs used, Cisco MDS 9000 Family switches use a special allocation scheme.
Some HBAs do not discover targets that have FC IDs with the same domain and area. Prior to Cisco SAN-OS
Release 2.0(1b), the Cisco SAN-OS software maintained a list of tested company IDs that do not exhibit this behavior. These HBAs were allocated with single FC IDs, and for others a full area was allocated.
The FC ID allocation scheme available in Release 1.3 and earlier, allocates a full area to these HBAs. This allocation isolates them to that area and are listed with their pWWN during a fabric login. The allocated FC
IDs are cached persistently and are still available in Cisco SAN-OS Release 2.0(1b) (see the
FC ID Allocation for HBAs, on page 305 ).
To allow further scalability for switches with numerous ports, the Cisco NX-OS software maintains a list of
HBAs exhibiting this behavior. Each HBA is identified by its company ID (also known known as Organizational
Unique Identifier, or OUI) used in the pWWN during a fabric login. A full area is allocated to the N ports with company IDs that are listed, and for the others a single FC ID is allocated. Regardless of the kind (whole area or single) of FC ID allocated, the FC ID entries remain persistent.
This section includes the following topics:
Default Company ID List
All switches in the Cisco MDS 9000 Family that ship with Cisco SAN-OS Release 2.0(1b) or later, or NX-OS
4.1(1) contain a default list of company IDs that require area allocation. Using the company ID reduces the number of configured persistent FC ID entries. You can configure or modify these entries using the CLI.
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
305
Advanced Features and Concepts
Default Company ID List
Caution Persistent entries take precedence over company ID configuration. If the HBA fails to discover a target, verify that the HBA and the target are connected to the same switch and have the same area in their FC IDs, then perform the following procedure:1. Shut down the port connected to the HBA.2. Clear the persistent FC ID entry.3. Get the company ID from the Port WWN.4. Add the company ID to the list that requires area allocation.5. Bring up the port.
The list of company IDs have the following characteristics:
• A persistent FC ID configuration always takes precedence over the list of company IDs. Even if the company ID is configured to receive an area, the persistent FC ID configuration results in the allocation of a single FC ID.
• New company IDs added to subsequent releases are automatically added to existing company IDs.
• The list of company IDs is saved as part of the running and saved configuration.
• The list of company IDs is used only when the fcinterop FC ID allocation scheme is in auto mode. By default, the interop FC ID allocation is set to auto, unless changed.
Tip We recommend that you set the fcinterop FC ID allocation scheme to auto and use the company ID list and persistent FC ID configuration to manipulate the FC ID device allocation.
Use the fcinterop FCID allocation auto command to change the FC ID allocation and the show running-config command to view the currently allocated mode.
• When you issue a write erase , the list inherits the default list of company IDs shipped with a relevant release.
To allocate company IDs, follow these steps:
Step 1
Step 2
Step 3
Step 4 switch# config terminal switch(config)#
Enters configuration mode.
switch(config)# fcid-allocation area company-id 0x003223
Adds a new company ID to the default list.
switch(config)# no fcid-allocation area company-id 0x00E069
Deletes a company ID from the default list.
switch(config)# fcid-allocation area company-id 0x003223
Adds a new company ID to the default list.
306
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Advanced Features and Concepts
Verifying the Company ID Configuration
Verifying the Company ID Configuration
You can view the configured company IDs by issuing the show fcid-allocation area command (see
entries are listed next. Entries are listed even if they were part of the default list and you later removed them.
Displays the List of Default and Configured Company IDs switch# show fcid-allocation area
FCID area allocation company id info:
00:50:2E <-------------------- Default entry
00:50:8B
00:60:B0
00:A0:B8
00:E0:69
00:30:AE + <------------------ User-added entry
00:32:23 +
00:E0:8B * <------------- Explicitly deleted entry (from the original default list)
Total company ids: 7
+ - Additional user configured company ids.
* - Explicitly deleted company ids from default list.
You can implicitly derive the default entries shipped with a specific release by combining the list of
Company IDs displayed without any identification with the list of deleted entries.
You can also view or obtain the company IDs in a specific WWN by issuing the show fcid-allocation company-id-from-wwn command (see
Displays the Company ID for the Specified WWN, on page
307 ). Some WWN formats do not support company IDs. In these cases, you many need to configure
the FC ID persistent entry.
Displays the Company ID for the Specified WWN switch# show fcid-allocation company-id-from-wwn 20:00:00:05:30:00:21:60
Extracted Company ID: 0x000530
Switch Interoperability
Interoperability enables the products of multiple vendors to interact with each other. Fibre Channel standards guide vendors towards common external Fibre Channel interfaces.
If all vendors followed the standards in the same manner, then interconnecting different products would become a trivial exercise. However, not all vendors follow the standards in the same way, thus resulting in interoperability modes. This section briefly explains the basic concepts of these modes.
Each vendor has a regular mode and an equivalent interoperability mode, which specifically turns off advanced or proprietary features and provides the product with a more amiable standards-compliant implementation.
Note For more information on configuring interoperability for the Cisco MDS 9000 Family switches, refer to the
Cisco MDS 9000 Family Switch-to-Switch Interoperability Configuration Guide .
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
307
Advanced Features and Concepts
About Interop Mode
This section includes the following topics:
About Interop Mode
Cisco NX-OS software supports the following four interop modes:
• Mode 1— Standards based interop mode that requires all other vendors in the fabric to be in interop mode.
• Mode 2—Brocade native mode (Core PID 0).
• Mode 3—Brocade native mode (Core PID 1).
• Mode 4—McData native mode.
For information about configuring interop modes 2, 3, and 4, refer to the Cisco MDS 9000 Family
Switch-to-Switch Interoperability Configuration Guide .
Table 27: Changes in Switch Behavior When Interoperability Is Enabled , on page 308
lists the changes in switch behavior when you enable interoperability mode. These changes are specific to switches in the Cisco
MDS 9000 Family while in interop mode.
Table 27: Changes in Switch Behavior When Interoperability Is Enabled
Switch Feature
Domain IDs
Timers
F_S_TOV
D_S_TOV
E_D_TOV
R_A_TOV
Trunking
Default zone
Changes if Interoperability Is Enabled
Some vendors cannot use the full range of 239 domains within a fabric.
Domain IDs are restricted to the range 97-127. This is to accommodate McData’s nominal restriction to this same range. They can either be set up statically (the
Cisco MDS switch accept only one domain ID, if it does not get that domain ID it isolates itself from the fabric) or preferred. (If it does not get its requested domain
ID, it accepts any assigned domain ID.)
All Fibre Channel timers must be the same on all switches as these values are exchanged by E ports when establishing an ISL. The timers are F_S_TOV,
D_S_TOV, E_D_TOV, and R_A_TOV.
Verify that the Fabric Stability Time Out Value timers match exactly.
Verify that the Distributed Services Time Out Value timers match exactly.
Verify that the Error Detect Time Out Value timers match exactly.
Verify that the Resource Allocation Time Out Value timers match exactly.
Trunking is not supported between two different vendor’s switches. This feature may be disabled on a per port or per switch basis.
The default zone behavior of permit (all nodes can see all other nodes) or deny
(all nodes are isolated when not explicitly placed in a zone) may change.
308
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Advanced Features and Concepts
Configuring Interop Mode 1
Switch Feature
Zoning attributes
Zone propagation
VSAN
TE ports and
PortChannels
FSPF
Changes if Interoperability Is Enabled
Zones may be limited to the pWWN and other proprietary zoning methods (physical port number) may be eliminated.
Note Brocade uses the cfgsave command to save fabric-wide zoning configuration. This command does not have any effect on Cisco MDS
9000 Family switches if they are part of the same fabric. You must explicitly save the configuration on each switch in the Cisco MDS 9000
Family.
Some vendors do not pass the full zone configuration to other switches, only the active zone set gets passed.
Verify that the active zone set or zone configuration has correctly propagated to the other switches in the fabric.
Interop mode only affects the specified VSAN.
Note Interop modes cannot be enabled on FICON-enabled VSANs.
TE ports and PortChannels cannot be used to connect Cisco MDS to non-Cisco
MDS switches. Only E ports can be used to connect to non-Cisco MDS switches.
TE ports and PortChannels can still be used to connect an Cisco MDS to other
Cisco MDS switches even when in interop mode.
The routing of frames within the fabric is not changed by the introduction of interop mode. The switch continues to use src-id, dst-id, and ox-id to load balance across multiple ISL links.
Domain reconfiguration disruptive
This is a switch-wide impacting event. Brocade and McData require the entire switch to be placed in offline mode and/or rebooted when changing domain IDs.
Domain reconfiguration nondisruptive
This event is limited to the affected VSAN. Only Cisco MDS 9000 Family switches have this capability—only the domain manager process for the affected VSAN is restarted and not the entire switch.
Name server
IVR
Verify that all vendors have the correct values in their respective name server database.
IVR-enabled VSANs can be configured in no interop (default) mode or in any of the interop modes.
Configuring Interop Mode 1
The interop mode1 in Cisco MDS 9000 Family switches can be enabled disruptively or nondisruptively.
Note Brocade’s msplmgmtdeactivate command must explicitly be run prior to connecting from a Brocade switch to either Cisco MDS 9000 Family switches or to McData switches. This command uses Brocade proprietary frames to exchange platform information, which Cisco MDS 9000 Family switches or McData switches do not understand. Rejecting these frames causes the common E ports to become isolated.
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
309
Advanced Features and Concepts
Configuring Interop Mode 1
To configure interop mode 1 in any switch in the Cisco MDS 9000 Family, follow these steps:
Step 1
Step 2
Step 3
Step 4
Place the VSAN of the E ports that connect to the OEM switch in interoperability mode.
switch# config terminal switch(config)# vsan database switch(config-vsan-db)# vsan 1 interop 1 switch(config-vsan-db)# exit switch(config)#
Note You cannot enable interop modes on FICON-enabled VSANs.
Assign a domain ID in the range of 97 (0x61) through 127 (0x7F).
Note This is an limitation imposed by the McData switches.
switch(config)# fcdomain domain 100 preferred vsan 1
In Cisco MDS 9000 switches, the default is to request an ID from the principal switch. If the preferred option is used,
Cisco MDS 9000 switches request a specific ID, but still join the fabric if the principal switch assigns a different ID. If the static option is used, the Cisco MDS 9000 switches do not join the fabric unless the principal switch agrees and assigns the requested ID.
Note When changing the domain ID, the FC IDs assigned to N ports also change.
Change the Fibre Channel timers (if they have been changed from the system defaults).
Note The Cisco MDS 9000, Brocade, and McData FC Error Detect (ED_TOV) and Resource Allocation (RA_TOV) timers default to the same values. They can be changed if needed. The RA_TOV default is 10 seconds, and the
ED_TOV default is 2 seconds. Per the FC-SW2 standard, these values must be the same on each switch within the fabric.
switch(config)# fctimer e_d_tov ?
<1000-4000> E_D_TOV in milliseconds(1000-4000) switch(config)# fctimer r_a_tov ?
<5000-100000> R_A_TOV in milliseconds(5000-100000)
When making changes to the domain, you may or may not need to restart the Cisco MDS domain manager function for the altered VSAN.
• Force a fabric reconfiguration with the disruptive option.
switch(config)# fcdomain restart disruptive vsan 1 or
• Do not force a fabric reconfiguration.
switch(config# fcdomain restart vsan 1
310
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Advanced Features and Concepts
Configuring Interop Mode 1
Configuring Interop Mode 1
commandsTo verify the resulting status of issuing the interoperability command in any switch in the Cisco
MDS 9000 Family, follow these steps:
SUMMARY STEPS
1.
Use the show version command to verify the version.
2.
Use the show interface brief command to verify if the interface states are as required by your configuration.
3.
Use the show run command to verify if you are running the desired configuration.
4.
Use the show vsan command to verify if the interoperability mode is active.
5.
Use the show fcdomain vsan command to verify the domain ID.
6.
Use the show fcdomain domain-list vsan command to verify the local principal switch status.
7.
Use the show fspf internal route vsan command to verify the next hop and destination for the switch.
8.
Use the show fcns data vsan command to verify the name server information.
DETAILED STEPS
Step 1
Step 2
Use the show version command to verify the version.
switch# show version
Cisco Storage Area Networking Operating System (NX-OS) Software
TAC support: http://www.cisco.com/tac
Copyright (c) 2002-2003, Cisco Systems, Inc. All rights reserved.
The copyrights to certain works contained herein are owned by
Cisco Systems, Inc. and/or other third parties and are used and distributed under license. Some parts of this software are covered under the GNU Public License. A copy of the license is available at http://www.gnu.org/licenses/gpl.html.
Software
BIOS: loader: version 1.0.8
version 1.1(2) kickstart: version 2.0(1) [build 2.0(0.6)] [gdb] system: version 2.0(1) [build 2.0(0.6)] [gdb]
BIOS compile time: 08/07/03 kickstart image file is: bootflash:///m9500-sf1ek9-kickstart-mzg.2.0.0.6.bin
kickstart compile time: 10/25/2010 12:00:00 system image file is: bootflash:///m9500-sf1ek9-mzg.2.0.0.6.bin
system compile time:
Hardware
10/25/2020 12:00:00
RAM 1024584 kB bootflash: 1000944 blocks (block size 512b) slot0: 0 blocks (block size 512b)
172.22.92.181 uptime is 0 days 2 hours 18 minute(s) 1 second(s)
Last reset at 970069 usecs after Tue Sep 16 22:31:25 1980
Reason: Reset Requested by CLI command reload
System version: 2.0(0.6)
Service:
Use the show interface brief command to verify if the interface states are as required by your configuration.
switch# show int brief
Interface Vsan Admin Admin Status
Mode Trunk
Oper Oper Port-channel
Mode Speed
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
311
Advanced Features and Concepts
Configuring Interop Mode 1
Step 3
Step 4
Mode (Gbps)
-------------------------------------------------------------------fc2/1 fc2/2
1
1 auto auto on on up up
E
E
2
2
--
-fc2/3 fc2/4 fc2/5 fc2/6 fc2/7 fc2/8 fc2/9 fc2/10
1
1
1
1
1
1
1
1 auto auto auto auto auto auto auto auto on on on on on on on on fcotAbsent down down down up fcotAbsent down down
--
--
--
--
E
--
--
--
--
--
--
--
1
--
--
--
--
--
--
--
--
--
--
--
Use the show run command to verify if you are running the desired configuration.
switch# show run
Building Configuration...
interface fc2/1 no shutdown interface fc2/2 no shutdown interface fc2/3 interface fc2/4 interface fc2/5 interface fc2/6 interface fc2/7 no shutdown interface fc2/8 interface fc2/9 interface fc2/10
<snip> interface fc2/32 interface mgmt0 ip address 6.1.1.96 255.255.255.0
switchport encap default no shutdown vsan database vsan 1 interop boot system bootflash:/m9500-system-253e.bin sup-1 boot kickstart bootflash:/m9500-kickstart-253e.bin sup-1 boot system bootflash:/m9500-system-253e.bin sup-2 boot kickstart bootflash:/m9500-kickstart-253e.bin sup-2 callhome fcdomain domain 100 preferred vsan 1 ip route 6.1.1.0 255.255.255.0 6.1.1.1
ip routing line console databits 5 speed 110 logging linecard ssh key rsa 512 force ssh server enable switchname MDS9509 username admin password 5 $1$Li8/fBYX$SNc72.xt4nTXpSnR9OUFB/ role network-admin
Use the show vsan command to verify if the interoperability mode is active.
switch# show vsan 1 vsan 1 information name:VSAN0001 stalactites interoperability mode:yes
312
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Advanced Features and Concepts
Configuring Interop Mode 1
Step 5
Step 6
Step 7
<-------------------verify mode loadbalancing:src-id/dst-id/oxid operational state:up
Use the show fcdomain vsan command to verify the domain ID.
switch# show fcdomain vsan 1
The local switch is a Subordinated Switch.
Local switch run time information:
State: Stable
Local switch WWN: 20:01:00:05:30:00:51:1f
Running fabric name: 10:00:00:60:69:22:32:91
Running priority: 128
Current domain ID: 0x64(100)
<--------------verify domain id
Local switch configuration information:
State: Enabled
Auto-reconfiguration: Disabled
Contiguous-allocation: Disabled
Configured fabric name: 41:6e:64:69:61:6d:6f:21
Configured priority: 128
Configured domain ID: 0x64(100) (preferred)
Principal switch run time information:
Running priority: 2
Interface
----------------
Role
-------------
RCF-reject
-----------fc2/1 fc2/2 fc2/7
----------------
Downstream
Downstream
Upstream
-------------
Disabled
Disabled
Disabled
------------
Use the show fcdomain domain-list vsan command to verify the local principal switch status.
switch# show fcdomain domain-list vsan 1
Number of domains: 5
Domain ID WWN
---------
0x61(97)
0x62(98)
-----------------------
10:00:00:60:69:50:0c:fe
20:01:00:05:30:00:47:9f
0x63(99)
0x64(100)
0x65(101)
---------
10:00:00:60:69:c0:0c:1d
20:01:00:05:30:00:51:1f [Local]
10:00:00:60:69:22:32:91 [Principal]
-----------------------
Use the show fspf internal route vsan command to verify the next hop and destination for the switch.
switch# show fspf internal route vsan 1
FSPF Unicast Routes
---------------------------
VSAN Number Dest Domain Route Cost Next hops
-----------------------------------------------
1 0x61(97) 500 fc2/2
1 0x62(98) 1000
1
1
0x63(99)
0x65(101)
500
1000 fc2/1 fc2/2 fc2/1 fc2/7
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
313
Default Settings
Step 8 Use the show fcns data vsan command to verify the name server information.
switch# show fcns data vsan 1
VSAN 1:
------------------------------------------------------------------
FCID TYPE PWWN (VENDOR) FC4-TYPE:FEATURE
------------------------------------------------------------------
0x610400 N 10:00:00:00:c9:24:3d:90 (Emulex) scsi-fcp
0x6105dc
0x6105e0
0x6105e1
0x6105e2
0x6105e4
NL
NL
NL
NL
NL
21:00:00:20:37:28:31:6d (Seagate)
21:00:00:20:37:28:24:7b (Seagate)
21:00:00:20:37:28:22:ea (Seagate)
21:00:00:20:37:28:2e:65 (Seagate)
21:00:00:20:37:28:26:0d (Seagate) scsi-fcp scsi-fcp scsi-fcp scsi-fcp scsi-fcp
0x630400
0x630500
0x6514e2
N
N
NL
10:00:00:00:c9:24:3f:75 (Emulex)
50:06:01:60:88:02:90:cb
21:00:00:20:37:a7:ca:b7 (Seagate)
0x6514e4
0x6514e8
NL
NL
21:00:00:20:37:a7:c7:e0 (Seagate)
21:00:00:20:37:a7:c7:df (Seagate)
0x651500 N 10:00:00:e0:69:f0:43:9f (JNI)
Total number of entries = 12 scsi-fcp scsi-fcp scsi-fcp scsi-fcp scsi-fcp
Advanced Features and Concepts
Default Settings
Table 28: Default Settings for Advanced Features , on page 314
lists the default settings for the features included in this chapter.
Table 28: Default Settings for Advanced Features
Parameters
CIM server
CIM server security protocol
D_S_TOV
E_D_TOV
Default
Disabled
HTTP
5,000 milliseconds.
2,000 milliseconds.
R_A_TOV
Timeout period to invoke fctrace
10,000 milliseconds.
5 seconds.
Number of frame sent by the fcping feature 5 frames.
Remote capture connection protocol TCP.
Remote capture connection mode
Local capture frame limit s
FC ID allocation mode
Loop monitoring
Passive.
10 frames.
Auto mode.
Disabled.
314
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Advanced Features and Concepts
Parameters
D_S_TOV
E_D_TOV
R_A_TOV
Interop mode
Default
5,000 msec
2,000 msec
10,000 msec
Disabled
Default Settings
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
315
Default Settings
Advanced Features and Concepts
316
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
C H A P T E R
12
Configuring Fibre Channel Common Transport
Management Security
This chapter describes the Fibre Channel Common Transport (FC-CT) Management Security feature for Cisco
MDS 9000 Series switches.
•
About Fibre Channel Common Transport , on page 317
•
Configuration Guidelines, on page 317
•
Configuring the Fibre Channel Common Transport Query, on page 318
•
Verifying Fibre Channel Common Transport Management Security, on page 318
•
About Fibre Channel Common Transport
With the FC-CT management security feature, you can configure the network in such a manner that only a storage administrator or a network administrator can send queries to a switch and access information such as devices that are logged in devices in the fabric, switches in the fabric, how they are connected, how many ports each switch has and where each port is connected, configured zone information and privilege to add or delete zone and zone sets, and host bus adapter (HBA) details of all the hosts connected in the fabric.
Note In Cisco MDS NX-OS Release 6.2(9), the FC management feature is disabled by default. To enable FC management feature, use the fc-management enable command.
You can configure which pWWNs can send FC-CT management query and modify request to the management server. When any of the modules, such as a zone server, unzoned Fibre Channel name server (FCNS), or
Fabric Configuration Server (FCS) receives an FC-CT management query, they perform a read operation on the FC-management database. If device is found in FC-management database, a reply is sent according to the permissions granted. If the device is not found in the FC-management database, each module sends a reject.
If FC-management is disabled, each module processes each management query.
Configuration Guidelines
The FC-management security feature has the following configuration guidelines:
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
317
Configuring Fibre Channel Common Transport Management Security
Configuring the Fibre Channel Common Transport Query
• When the FC-management security feature is enabled on a Cisco MDS switch, all management queries to the server are rejected unless the port world-wide name (pWWN) of the device that is sending management queries is added to FC-management database.
• When you enable FC Management, FC-CT management server queries from N_Port Virtualization (NPV) switches to N_Port Identifier Virtualization (NPIV) switches are rejected. We recommend that you add the switch world-wide name (sWWN) of the NPV switch to the FC management database of the NPIV switch after enabling the FC-management security feature.
Configuring the Fibre Channel Common Transport Query
To configure the FC-CT management security, follow these steps:
Step 1
Step 2
Step 3
Step 4
Step 5 switch# config terminal
Enters configuration mode.
switch(config)# fc-management enable
Enables the FC-CT management security.
switch(config)# fc-management database vsan 1
Configures the FC-CT management Security database.
switch(config-fc-mgmt)# pwwn 1:1:1:1:1:1:1:1 feature all operation both
Adds the pWWN to the FC management database. You also can use these optional keywords when configuring the pwwn command:
• fcs— Enables or disables FC-CT query for fabric conf-server.
• fdmi—Enables or disables FC-CT query for FDMI.
• unzoned-ns—Enables or disables FC-CT query for unzoned name-server.
• zone—Enables or disables FC-CT query for zone-server.
switch# show fc-managment database
Displays the configured FC-CT management information.
Verifying Fibre Channel Common Transport Management
Security
The show fc-management database command displays the configured FC-CT management security feature information, see example
Displays the Contents of the Fibre Channel Common Transport Query, on page
318
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Configuring Fibre Channel Common Transport Management Security
Default Settings
Displays the Contents of the Fibre Channel Common Transport Query switch# show fc-management database
--------------------------------------------------------------
VSAN PWWN FC-CT Permissions per FC services
--------------------------------------------------------------
1 01:01:01:01:01:01:01:01 Zone(RW), Unzoned-NS(RW), FCS(RW), FDMI(RW)
1 02:02:02:02:02:02:02:02 Zone(R), Unzoned-NS(R), FCS(R), FDMI(R)
1 03:03:03:03:03:03:03:03 Zone(W), Unzoned-NS(W), FCS(W), FDMI(W)
--------------------------------------------------------------
Total 3 entries switch#
To verify the if the FC-management security feature is enabled or not, use the show fc-management status command: switch# show fc-management status
Mgmt Security Disabled switch#
Default Settings
Table 29: Default FC Management Settings , on page 319
lists the default settings for the FC management security feature in a Cisco MDS 9000 Family switch.
Table 29: Default FC Management Settings
Parameters Default
FC-management Disabled
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
319
Default Settings
Configuring Fibre Channel Common Transport Management Security
320
Cisco MDS 9000 Series Fabric Configuration Guide, Release 9.x
Laadi alla
Reklaam