ADC Telecommunications F8I-PSM230WM FWP-W4MT000MOD User Manual

Add to my manuals
51 Pages

advertisement

ADC Telecommunications F8I-PSM230WM FWP-W4MT000MOD User Manual | Manualzz

FlexWave

Prism Remote Unit RF Module

Installation Guide

Single-Slot RF Module

Dual-Band Dual-Slot RF Module

HDM RF Module Legacy Dual-Slot 40W RF Module

This installation guide provides the information you need to install TE Connectivity FlexWave Prism RF Modules into a Prism Remote Unit (PRU).

Installation instructions are provided for the following Prism Remote Unit RF Modules:

• Single-Bay RF Modules, which includes the HDM RF Modules

• Dual-Bay RF Modules

– Dual-Band RF Modules

– Legacy 40W RF Modules.

TE Connectivity, TE and TE connectivity (logo) FlexWave, InterReach, InterReach Fusion and InterReach Unison are trademarks.

All other logos, products and/or company names referred to herein might be trademarks of their respective owners.

The information given herein, including drawings, illustrations and schematics which are intended for illustration purposes only, is believed to be reliable. However, TE

Connectivity makes no warranties as to its accuracy or completeness and disclaims any liability in connection with its use. TE Connectivity's obligations shall only be as set forth in TE Connectivity's Standard Terms and Conditions of Sale for this product and in no case will TE Connectivity be liable for any incidental, indirect or consequential damages arising out of the sale, resale, use or misuse of the product. Users of TE Connectivity products should make their own evaluation to determine the suitability of each such product for the specific application.

T

ABLE OF

C

ONTENTS

Document Overview ...........................................................................................................................................................................................3

Revision History.......................................................................................................................................................................................................5

Document Cautions and Notes ...............................................................................................................................................................................5

Abbreviations Used in this Guide ............................................................................................................................................................................5

Overview of RF Modules for Prism Remote Units ................................................................................................................................................6

RF Module Digital/Analog Radio Transceivers ........................................................................................................................................................7

RF Module Types.....................................................................................................................................................................................................9

Single- and Dual-Bay RF Modules with Classic or SuperDARTs .......................................................................................................................9

HDM RF Modules ..........................................................................................................................................................................................10

Legacy Dual-Bay 40W RF Modules ................................................................................................................................................................11

RF Module Components ....................................................................................................................................................................................12

Linear Power Amplifiers ........................................................................................................................................................................................13

Duplexer and Low Noise Amplifier........................................................................................................................................................................14

Digital Processing Module.....................................................................................................................................................................................14

Cables ....................................................................................................................................................................................................................14

RF Group Assignments for PRU RF Module Bays ................................................................................................................................................15

Understanding RF Cable Rules ...........................................................................................................................................................................18

RF Module Cables and Supported Bay Use for Single-Card, Dual-Card, and HDM RF Modules ...........................................................................18

RF Module Cables and Supported Bay Installations for Legacy Dual-Bay 40W RF Modules.................................................................................20

Install the RF Module(s) ....................................................................................................................................................................................21

Safety Precautions.................................................................................................................................................................................................21

Guard against Damage from Electro-Static Discharge ..........................................................................................................................................22

Unpack and Inspect the RF Module ......................................................................................................................................................................22

Remove Release Liners from the RF Module ........................................................................................................................................................23

Check the DC Power Switch for the Module Bay ..................................................................................................................................................24

Dual-Bay Modules Only—Remove the Module Bay Shelf.....................................................................................................................................25

Install the RF Module into the Prism Remote Chassis...........................................................................................................................................26

Secure RF Module Latches ....................................................................................................................................................................................34

Connect Latches on Single-Bay and HDM RF Modules .................................................................................................................................34

Connect Latches on Dual-Bay RF Modules....................................................................................................................................................35

Latches on Legacy Dual-Bay 40W RF Modules..............................................................................................................................................36

Verify that the RF Module Mounting Hook is Engaged.................................................................................................................................36

Connect the RF Module Cables to the PRU Chassis ..............................................................................................................................................36

Connecting Cables in a Single-Bay RF Module Installation ...........................................................................................................................37

Connecting Cables in a Dual-Bay RF Module Installation..............................................................................................................................40

Power on the RF Module(s) and the Prism Remote Unit ......................................................................................................................................44

Close the Remote Unit Door and Solar Shield.......................................................................................................................................................46

Provision the Prism Remote Unit ..........................................................................................................................................................................46

FlexWave Notch Filter (FWP-SPRINTFILTER) ......................................................................................................................................................47

Standards Certification......................................................................................................................................................................................49

Accessing User Documentation on the TE Customer Portal................................................................................................................................50

Contacting TE Connectivity................................................................................................................................................................................51

Page 2

©2015 TE Connectivity

FlexWave Prism Remote Unit RF Module Installation Guide

TECP-77-141 Issue 8 • 300001744178 Rev H • August 2015

D

OCUMENT

O

VERVIEW

Table 1

lists the RF Modules that this installation guide supports.

Table 1. FlexWave Prism RF Modules Supported in this Installation Guide

Catalog Number Description

High-Density Module (HDM); Single Bay

FWP-L4MT000MOD 20W 700 lABC Module, MIMO HDM, Single-Bay

FWP-L4MTU4MMO D 20W 700 lABC/700uC, Dual, Single-Bay

FWP-U4MT000MOD 20W 700 uC Module, MIMO HDM, Single-Bay

FWP-44MT000MOD 20W 800 MIMO, Single Bay, with two External Filters

FWP-441T841MOD 20W 800 SMR/ 1900 PCS, Dual RF Module

FWP-C4MT000MOD 20W 850 Cell/1900 PCS, Dual, Single-Bay

FWP-B4MT000MOD 20W 850 DUAL, MIMO, Single Bay

FWP-84MT000MOD 20W 1900 PCS Dual MIMO, Single-Bay

FWP-84MTA4MMOD 20W 1900/2100 Dual, Single Bay

F W P - W 4 M T 0 00 M O D 20W 2300 WCS FDD, MIMO HDM, Single-Bay

FWP-A416000MOD 20W AWS Module, Non-Diversity, HDM, Single Bay

FWP-A4MT000MOD 20W AWS Band 4 MIMO HDM, Single-Bay

FWP-8416000MOD 20W PCS Module, Non-Diversity, HDM, Single Bay

FWP-B410000M OD 20W Wideband Cell Module, Non-Diversity

FWP-A81T000MOD 40W AWS Band 4 SISO HDM, Single-Bay

FWP-881T000MOD 40W PCS Band 2 & 25 SISO HDM, Single-Bay

FWP-B810100M OD 40W Wideband Cell Module, Non-Diversity, Single-Bay

Single SuperDART; Single Bay

FWP-I210000MOD

FWP-6216000MOD

6.5W 800 APAC Module, Non-Diversity, Classic (Extended 1 MHz)

10W 900 EGSM, Non-Diversity, Single SuperDART

FWP-K216000MOD 10W 900 P-GSM Module, Non-Diversity, Single SuperDART

FWP-F216000MOD 10W APAC EGSM Module, Single SuperDART

FWP-7416000MOD 20W 1800 GSM, Non-Diversity, Single SuperDART

FWP-9416D00MOD 20W 2100 UMTS Module, DIV Ready, Single SuperDART

FWP-9416000MOD

FWP-L416000MOD

20W 2100 UMTS, Non-Diversity, Single SuperDART

20W 700 Lower ABC Module, Non-Diversity, Single SuperDART

FWP-U416000MOD 20W 700 LTE, UPPER C, SISO, Single SuperDART

FWP-U816100MOD 40W 700 Upper C Module, Non-Diversity, Single SuperDART, Single-Bay

Dual SuperDART; Single Bay

FWP-741S000MOD 20W 1800 GSM, Non-Diversity, DL SuperDART

FWP-A41S000MOD 20W AWS 2100 12S

FWP-841S000MOD 20W PCS 1900 12S

FWP-941S000MOD 20W, UMTS 2100, Non-Diversity, DL SuperDART

FlexWave Prism Remote Unit RF Module Installation Guide

TECP-77-141 Issue 8 • 300001744178 Rev H • August 2015

Page 3

©2015 TE Connectivity

Table 1. FlexWave Prism RF Modules Supported in this Installation Guide (Cont.)

Catalog Number Description

Two Single SuperDARTs; Diversity; Single Bay

FWP-6226000MOD

FWP-K226000MOD

FWP-7426000MOD

FWP-9426000MOD

FWP-A426000MOD

FWP-8426000MOD

10W 900 EGSM, Diversity, Single SuperDART

10W 900 P-GSM Module, Diversity, Single SuperDART

20W 1800 GSM, Diversity, Single SuperDART

20W, 2100 UMTS, Diversity, Single SuperDART

20W AWS Module, Diversity, Single SuperDART

20W PCS Module, Diversity, Single SuperDART

Classic DART; Single Bay

FWP-4210000MOD

FWP-8420000MOD

FWP-8410000MOD

FWP-A420000MOD

FWP-A410000MOD

FW P-B 4200 00 MO D

FWP-J410D00MOD

6.5W 800 SMR Module, Non-Diversity, Classic

20W 1900 PCS Diversity

20W 1900 PCS Non-Diversity

20W 2100 AWS Diversity

20W 2100 AWS Non-Diversity

20W Wideband Cell Module, Diversity, Classic

20W 850 Cell (870-890) Module, Diversity Ready, Classic

Classic DART; Two-Bay

FWP-8810000MOD

FWP-A810000MOD

Dual Classic DART; Two-Bay

40W PCS Module, Non-Diversity, Classic (Dual-Bay)

40W AWS Module, Non-Diversity, Classic, Dual-Bay

F W P -D 21 0 0 0 0 M O D 6.5W 800/900 ESMR Module, Non-Diversity, Classic

The RF Modules listed in Table 1 are compatible only with the Remote Units listed in

Table 2 .

Table 2. Supported FlexWave Prism Remote Unit Chassis

Catalog Number

F P 1 - X XX X XX X X XX X R U

F P 2 - X XX X XX X X XX X R U

F P 3 - X XX X XX X X XX X R U

F P 4 - X XX X XX X X XX X R U

Description

Single-Bay Prism Remote

Dual-Bay Prism Remote

Tri-Bay Prism Remote

Quad-Bay Prism Remote

Page 4

©2015 TE Connectivity

FlexWave Prism Remote Unit RF Module Installation Guide

TECP-77-141 Issue 8 • 300001744178 Rev H • August 2015

Revision History

Table 3. Revision History

7

8

3

4

5

6

Issue Document Date Technical Updates

1

2

April 2012

February 2013

May 2013

October 2013

January 2014

August 2014

Original

Changed Prism Remote Unit model names from Single-/Dual-/Tri-/Quad-Band to Single-/Dual-/Tri-/Quad-Bay.

(TECP-77-201).

Added “Understanding RF Cable Rules” on page 18 ..

Added the 20W AWS Band 4 MIMO HDM, 40W AWS Band 4 SISO HDM and 40W PCS Band 25 SISO HDM RF Modules.

Added FWP-84MT000MOD and FWP-L4MTU4MMOD RF Modules, and added Table 13 on page 39 .

Added support for FWP-B4MT000MOD, FWP-44MT000MOD, and FWP-84MTA4MMOD RF Modules; added the external

FlexWave Notch Filter (FWP-SPRINTFILTER), see

“FlexWave Notch Filter (FWP-SPRINTFILTER)” on page 47 .

December 2014 Added caution about potential temporary loss of RF for HDM RF Modules after closing the chassis door.

March 2015 Adds support for the Dual 20W 2300 WCS FDD, MIMO, Single-Bay RF Module (F WP - W4MT 000MOD); adds

the Remote Unit Door and Solar Shield” on page 46

.

“Close

Document Cautions and Notes

Two types of messages, identified below, appear in the text:

CAUTION! Cautions indicate operations or steps that could cause personal injury, induce a safety problem in a managed device, destroy or corrupt information, or interrupt or stop services.

NOTE: Notes contain information about special circumstances.

Abbreviations Used in this Guide

DPM

EMC

ESD

EU

FCC

FDA

FRU

FWD

CDRH cm

DART dB dBm

DCS

DD

DIV

HDM

HMFOC

IC

LED

Center for Diseases and Radiological Health

Centimeter

Digital/Analog Radio Transceiver

Decibel

Decibel-milliwatts

Distributed Call Signaling

Digital Dividend

Diversity

Digital Processing Module

Electromagnetic Compatibility

Electro-Static Discharge

European Union

Federal Communications Commission

Food and Drug Administration

Fullband Remote Unit

Forward

High Density Module

Hardened Multi-Fiber Optic Connector

Industry Canada

Light-Emitting Diode

REV

RF

Rx

SDART

SeRF

SFP

TIM

Tx

LVDS

MHz

MIMO

MOD

PA

PRIM

PRU

PWR

UL

UMTS

W

WCS

Low-Voltage Differential Signaling

Megahertz

Multiple-Input Multiple-Output

Module

Power Amplifier

Primary

Prism Remote Unit

Power

Reverse

Radio Frequency

Receive

Super Digital/Analog Radio Transceiver

Serialized RF

Small Form-Factor Pluggable

Thermal-Interface Material

Transmit

Underwriters' Laboratories, Inc.

Universal Mobile Telecommunications System

Watt

Wireless Communications Services

FlexWave Prism Remote Unit RF Module Installation Guide

TECP-77-141 Issue 8 • 300001744178 Rev H • August 2015

Page 5

©2015 TE Connectivity

O

VERVIEW OF

RF M

ODULES FOR

P

RISM

R

EMOTE

U

NITS

Figure 1 illustrates the Prism Remote Unit (PRU), which controls RF emissions, interfaces with the FlexWave

Prism Host Unit.

Single-Bay

Prism Remote Unit

Dual-Bay

Prism Remote Unit

Tri-Bay

Prism Remote Unit

Quad-Bay

Prism Remote Unit

Figure 1. Prism Remote Units (PRUs)

Depending on the Prism Remote Unit model, a PRU enclosure can have from one to four RF Module bays and can support up to four RF Modules, as indicated by the model name. That is, the Single-Bay PRU has one RF Module bay and can only support one RF Module, and the Quad-Bay PRU has four RF Module bays and can support up to four RF Modules.

The function of the Remote Unit RF Modules on the Forward Path is to:

• convert the digitized RF transported from the Host to Analog RF

• amplify the Analog RF signal

• provide signal filtering.

The function of the Remote Unit RF Modules on the Reverse Path is to:

• convert the Analog RF from the handset to Digital RF for transport to the Host

• amplify the Digital RF signal

• provide signal filtering.

NOTE: The RF Modules are field replaceable, but cannot be serviced in the field.

Page 6

©2015 TE Connectivity

FlexWave Prism Remote Unit RF Module Installation Guide

TECP-77-141 Issue 8 • 300001744178 Rev H • August 2015

RF Module Digital/Analog Radio Transceivers

Each RF Module can support any of the following Digital/Analog Radio Transceiver (DART) combinations:

• one Classic DART or one Single SuperDART

• two Classic DARTs (i.e., the 6.5W 800/900 ESMR Module, Non-Diversity, Classic)

• two Classic DARTs—Diversity

• two Single SuperDARTs—Diversity

• one Dual SuperDART

• one or two sets of Tx and Rx Boards (HDM).

Each RF Module will have up to two 6-timeslot DARTs or one 12-timeslot DART per RF Module.

The DART type determines the maximum number of links, where there can be up to eight Classic DARTs or Single

SuperDARTs that support 39 MHz each, or up to 4 Dual SuperDARTs that support up to 75MHz each.

Prism supports the DART Module types listed below.

• Classic DARTs are 6-timeslot DARTs that support up to 35 MHz contiguous bandwidth (see

Table 4 on page 7 ).

• Single SuperDARTs are 6-timeslot DARTs that support two non-contiguous bands in the entire frequency

range of the DART, but cannot exceed 39 MHz total RF bandwidth (see Table 5 on page 8

).

Dual SuperDARTs are 12-timeslot DARTs that support up to 60-75 MHz (see Table 6 on page 8

)

NOTE:

NOTE:

Industry Canada PCS 20 dB nominal bandwidth is less than 61.5 MHz.

Industry Canada AWS 20 dB nominal bandwidth is less than 47.2 MHz

Table 4. Single-Position Classic DARTs

DART Module Type Maximum Bandwidth (MHz) Maximum Fiber Slots

800 APAC iDEN Classic

800 SMR Classic

850 Cell Classic

900 SMR Classic

19

7*

25

5

3

3

4

1

* Classic Prism RF Modules and Spectrum RAU support 18 MHz; Prism HDM 800 only supports 7 MHz, per Sprint direction.

FlexWave Prism Remote Unit RF Module Installation Guide

TECP-77-141 Issue 8 • 300001744178 Rev H • August 2015

Page 7

©2015 TE Connectivity

Table 5. Single-Position SuperDARTs (1)

DART Name

Host Units

Used in…

HEUs

Maximum

Frequency

Span (MHz)

Maximum

Bandwidth

(MHz)

Maximum

Fiber

Slots

1800 GSM SGL SuperDART

1900 PCS SGL SuperDART

2100 AWS SGL SuperDART

2100 UMTS SGL SuperDART

700 IABC SGL SuperDART

700 uC SGL SuperDART

900 EGSM SGL SuperDART

Yes

Yes

Yes

Yes

Yes

Yes

Yes

No

Yes

Yes

No

Yes

Yes

No

60

18

10

35

75

70

45

39

18

10

35

39

39

39

2

6

6

3

6

6

6

(1) When using a Host Unit with both a SeRF II and System Board II or III, the bandwidths and fiber for the following Single

SuperDARTs can be greater than 6 fiber slots, for full-band capability, when used in Host Unit Slots 1 and 3:

• 1800 GSM SGL SuperDART

• 1900 PCS SGL SuperDART

• 2100 AWS SGL SuperDART

• 2100 UMTS SGL SuperDART

This requires 12 fiber slots when full-band passband is selected for these Single SuperDARTs in Host Unit DART positions 1 and 3.

Table 6. Dual-Position SuperDARTs

DART Module Type

1800 GSM DL SuperDART

1900 PCS DL SuperDART

2100 AWS DL SuperDART

2100 UMTS DL SuperDART

Maximum

Bandwidth

(MHz)

75

70

45

60

Maximum

Fiber

Slots

12

12

8

12

Page 8

©2015 TE Connectivity

FlexWave Prism Remote Unit RF Module Installation Guide

TECP-77-141 Issue 8 • 300001744178 Rev H • August 2015

RF Module Types

The Remote Unit RF Modules are available in the following formats, and as described in the following sections:

“Single- and Dual-Bay RF Modules with Classic or SuperDARTs” on page 9

“HDM RF Modules” on page 10

“Legacy Dual-Bay 40W RF Modules” on page 11 .

Single- and Dual-Bay RF Modules with Classic or SuperDARTs

Figure 2

shows examples of Single- and Dual-Bay RF Modules, both of which have two DARTs.

Single-Bay RF Modules have the following elements:

• one or two DARTs

• one Duplexer that comprises

– one Low Noise Amplifier (LNA)

– one Power Detector (PD)

• one Linear Power Amplifier (LPA)

• one Remote DART Interface (RDI) board.

Single-Bay Dual-Card RF Module

Dual-Band Dual-Bay RF Modules have the following elements:

• two DARTs

• two Duplexers, each of which comprises

– one Low Noise Amplifier (LNA)

– one Power Detector (PD)

• one Linear Power Amplifier (LPA)

• one Remote DART Interface (RDI) board.

Dual-Band Dual-Bay RF Module

Figure 2. Single- and Dual-Bay RF Modules

FlexWave Prism Remote Unit RF Module Installation Guide

TECP-77-141 Issue 8 • 300001744178 Rev H • August 2015

Page 9

©2015 TE Connectivity

HDM RF Modules

High-Density Module (HDM) RF Modules ( Figure 3 ) are designed to provide the ability to deploy either a two

20W Multiple Input Multiple Output (MIMO) paths of the same band, known as a MIMO RF Module; two 20W

Single Input Single Output (SISO) with two different bands, known as dual RF Module; or a single 40W Single

Input Single Output (SISO) RF Module within a single-bay of a PRU. An HDM RF Module does the following:

• interfaces with one Host DART-either Classic or SuperDART, or one CDIU

• supports two non-contiguous RF slices up to 39 MHz total bandwidth in a Dual or MIMO configuration

• supports full bandwidth in a SISO configuration, up to 75 MHz

• supports 20W per band/Path in a Dual/MIMO RF Module

• supports up to 40W RF output power in a SISO RF Module.

The components of a PRU HDM RF Module are dependent on the module type, as listed in Table 7 .

Table 7. Components of PRU HDM RF Modules

RF Module Type

DPM LPA Duplexer

SISO

MIMO/Dual Band Module

1

1

1

2

1

2

LNA

1

2

Power

Detector

1

2

Rx Card

1

2

Tx Card

1

2

Page 10

©2015 TE Connectivity

Figure 3. HDM RF Modules

FlexWave Prism Remote Unit RF Module Installation Guide

TECP-77-141 Issue 8 • 300001744178 Rev H • August 2015

Legacy Dual-Bay 40W RF Modules

The Legacy Dual-Bay 40W RF Module (

Figure 5 ) is designed for AWS and PCS frequencies and is supported only

by Classic DARTs. The Legacy Dual-Bay 40W RF Module comprises:

• one Classic DART

• one Duplexer that comprises

– one Low Noise Amplifier (LNA)

– one Power Detector (PD)

• two Power Amplifiers (PAs)

• one Remote DART Interface (RDI) board.

NOTE: This manual describes how to install the PCS 1900 and AWS 2100 Non-Diversity RF Modules.

Figure 4. Legacy Dual-Bay 40W RF Module

FlexWave Prism Remote Unit RF Module Installation Guide

TECP-77-141 Issue 8 • 300001744178 Rev H • August 2015

Page 11

©2015 TE Connectivity

RF M

ODULE

C

OMPONENTS

Figure 5 shows typical RF Module components, using the Single-Bay RF Module as an example.

DARTs

Mounng latch

LNA

Mounng hook

(inside the Duplexer caviy)

Duplexer

Power Amplifier (PA)

NOTE: The RDI is internal to the RF Module and is therefore not shown.

Figure 5. Single-Bay RF Module Components

Figure 6 shows the components of an HDM RF Module.

DPM

Tx and Rx Cards

Page 12

©2015 TE Connectivity

Duplexers

Mounng hook

Power Amplifier

Figure 6. HDM RF Module Components

Mounng latch

FlexWave Prism Remote Unit RF Module Installation Guide

TECP-77-141 Issue 8 • 300001744178 Rev H • August 2015

Linear Power Amplifiers

The Linear Power Amplifier (LPA) is a high quality broadband RF amplifier used for achieving Prism product-rated power for the Remote Unit Tx forward path RF. The PAs are pass-band specific, with the maximum composite Tx power levels listed in

Table 8 for Single-Card, Dual-Card, and HDM RF Modules and Table 9 on page 13

for Legacy Dual-Bay 40W RF Modules.

The LPA is housed within the RF Module, and is not field serviceable.

Table 8. LPA Maximum Composite Tx Power Levels for Single-Card, Dual-Card, and HDM RF Modules

Passband

AWS 2100

Cellular 850

EGSM 900

DCS 1800

LTE 700 Lower ABC

LTE 700 Upper C

PCS 1900

PGSM 900

SMR 800

SMR 900

UMTS 2100

2300 WCS

Maximum dBm

40

43

38

42

43

43

46

43

46

46

40

42

43

43

46

43

Watts

10

20

6.5

15.8

20

20

40

20

40

20

40

20

40

10

15.8

20

Bandwidth (MHz) supported across entire spectrum

HDM

Single Super DART

Classic

DART

Dual

SuperDART

Dual/MIMO SISO

25

7

NA

39

10

10

10

39

39

25

35

39

18

39

NA

25

25

7

NA

60

10

10

10

70

70

25

35

75

18

45

45

25

39

39

NA

NA

35

39

18

10

10

39

39

25

NA

NA

39

10

NA

NA

25

25

NA

NA

NA

NA

NA

NA

NA

NA

7

5

NA

NA

NA

NA

NA

60

NA

NA

NA

70

70

NA

NA

75

NA

45

45

NA

NOTE:

Table 9. LPA Maximum Composite Tx Power Levels for Legacy Dual-Bay 40W RF Modules

Passband

PCS 1900

AWS 2100

Maximum dBm

+46

+46

Watts

40

40

Bandwidth (MHz) supported across entire spectrum

Classic DART

35

35

Industry Canada 20 dB Pass Band Model Number FWP-C4MT000MOD Cellular 850 MHz = 26.3 MHz and the PCS 1900 = 66.8 MHz.

FlexWave Prism Remote Unit RF Module Installation Guide

TECP-77-141 Issue 8 • 300001744178 Rev H • August 2015

Page 13

©2015 TE Connectivity

Duplexer and Low Noise Amplifier

The RF Module provides the Remote Unit with an internal Duplexer that is optimized to provide the desired RF band-pass filtering and in-band equipment isolation between FWD and REV paths. The Duplexer provides the filtering necessary to the transmit and receive paths to and from the connected antenna.

The Duplexer for the Single- and Dual-Bay RF Modules and the Legacy Dual-Bay 40W RF Modules contains up to two REV path Low Noise Amplifiers (LNA for PRI and/or SEC reverse paths).

The Duplexer for an HDM RF Module does not have a Low Noise Amplifier.

Duplexers are not field serviceable.

Digital Processing Module

The Digital Processing Module (DPM) is found only in the HDM RF Modules. The DPM provides the primary processing and logic functions for the HDM RF Module. It also provides the primary power interface for the HDM

RF Module, and conversion of the native 28 Vdc voltage to lower voltages as necessary for functionality.

The DPM has a Transmit (Tx) Board and a Receive (Rx) Board:

• Tx Board—provides band specific filtering for the intended Transmit path.

Rx Board—provides band specific filtering for the intended Receive path.

Cables

Always provided at each RF Module shelf are five cables:

• two High-Speed Data Cables, which in this document are referred to as LVDS (Low-Voltage Differential

Signaling) cables

• two RF Cables (TX0/RX0) and (TX1/RX1)

• one Power (PWR) Cable.

The RF Module cables that are pre-installed in the PRU connect to the corresponding connectors on the RF

Module. The RF Module cables correlate to the antenna connectors on the bottom of the Remote Unit chassis.

Page 14

©2015 TE Connectivity

FlexWave Prism Remote Unit RF Module Installation Guide

TECP-77-141 Issue 8 • 300001744178 Rev H • August 2015

RF G

ROUP

A

SSIGNMENTS FOR

PRU RF M

ODULE

B

AYS

A PRU comprises from one to four RF Module bays. Figure 7

illustrates the numbering of RF Module bays and

DARTs.

Quad-Bay Remote Unit with Single-Card RF Modules

DART 7

DART 8

Bay D

DART 5

DART 6

Bay C

DART 3

DART 4

Bay B

DART 1

DART 2

Bay A

SeRF Module

Figure 7. RF Modules Bays in a PRU

FlexWave Prism Remote Unit RF Module Installation Guide

TECP-77-141 Issue 8 • 300001744178 Rev H • August 2015

Page 15

©2015 TE Connectivity

Table 10 lists how the FlexWave Prism EMS references the RF group assignments and corresponding

components of each RF Module.

Table 10. Remote Unit RF Group Assignments (from Top/Down)

Physical RF

Bay

DART

Number

LNA Number

Primary Diversity

LPA

Number for Single

LPA

LPA

Number for

Dual LPAs

D

C

6

5

8

7 7

8

6

7

5

5

B

4

3 3

4

3

4

3

2 2 2

A 1

1 1 1

NOTE: For software releases prior to 7.3, the LPAs were labeled as 1 , 2 , 3 , and 4 .

6

5

8

7

7

5

3

1

Power

Detector

Number for

Single PD

Power

Detector

Number for

Dual PDs

2

1

4

3

6

5

8

7

NOTE: For Classic dual position 40W RF Modules only: in a dual LPA system, the Configure Remote Forward

Gain page shows two values for the LPA status, one for each LPA. Changing the LPA Mode or resetting the LPA applies to both LPAs at the same time.

CAUTION! Should your system experience an LPA problem, refer to

Table 10

to ensure that you apply new settings

or troubleshoot the correct RF Module.

The Legacy Dual-Bay 40W RF Module occupies two bays in a PRU. Figure 8 shows the main components in a PRU

enclosure, with a Legacy 40W RF Module occupying Bays A and B. The controlling DART will always be in the upper bay (B or D), and the second LPA is always in the lower bay (A or C).

Page 16

©2015 TE Connectivity

FlexWave Prism Remote Unit RF Module Installation Guide

TECP-77-141 Issue 8 • 300001744178 Rev H • August 2015

Fans

Bay D (empty for future use)

Bay C (empty for future use)

Legacy Dual-Bay 40W RF Module in Bay B (upper slot) and

Bay A (lower slot) with the controlling DART in Bay B

SeRF Module and Power supplies

Four DC power switches

NOTE:

NOTE:

AC or DC power switch

Connecvity panel with Status LED

Figure 8. Legacy Dual-Bay 40W RF Module in a Quad-Bay PRU

If a Legacy Dual-Bay 40W RF Module AWS 2100 and a Legacy Dual-Bay 40W RF Module PCS 1900 are both installed in a Quad-Bay PRU, it is recommended that the PCS 1900 be installed in upper-most bay, and the AWS 2100 be installed in the lower-most bay.

To accommodate two-bay modules, you need to remove a module bay shelf as described in “Dual-Bay

Modules Only—Remove the Module Bay Shelf” on page 25 .

FlexWave Prism Remote Unit RF Module Installation Guide

TECP-77-141 Issue 8 • 300001744178 Rev H • August 2015

Page 17

©2015 TE Connectivity

U

NDERSTANDING

RF C

ABLE

R

ULES

• When installing a Diversity, MIMO or Dual-Band RF Module, both RF cables labeled MOD N TX0/RX0 and

MOD N TX1/RX1 shall be connected to the N-Style connections of the RF Module. Note that older labeling schemes used “PRI” and “DIV”. To match old labeling schemes to current labeling:

Old Label

PRI

DIV

New Label

TX0/RX0

TX1/RX1

• When installing a Non-Diversity or SISO RF Module, or an SMR 800/900 Dual-Band Dual-Bay RF Module:

– The MOD N TX0/RX0 cable shall be connected to the single available N-Style RF Connection of the RF

Module.

The MOD N TX1/RX1 cable shall be constrained to the existing cables using a tie wrap or similarly accepted fastener so it cannot be pinched or prevent the Remote Unit door from closing. Do not cut or attempt to otherwise remove this RF Cable.

• RF cables are hand-formable; however, cables must adhere to a minimum bend radius of 1-inch from the outlet of the integrated cable guide to the respective N-Style RF connection on the RF Module.

RF Module Cables and Supported Bay Use for Single-Card, Dual-Card, and HDM RF Modules

The RF cable and connector labels correspond to the RF Module bays in the Remote Unit chassis, where

MOD A is the bottom bay and MOD D is the top bay.

The cables and connectors have corresponding labels as shown in Table 11 for Single-Card, Dual-Card, and

HDM RF Modules. For Dual-Bay installations, the RF cables and connectors are labeled as MOD N TX0/RX0 and

MOD N TX1/RX1

, where

N

refers to the top bay of the double-bay installation. For example:

For a Dual-Bay installation in a Quad-Bay chassis in which the RF Module is installed in the Bay D and Bay

C combination, the RF cables and connectors are labeled as MOD D TX0/RX0 and MOD D TX1/RX1 .

– For a Dual-Bay installation in a Tri-Bay chassis in which the RF Module is installed in the Bay B and Bay

A combination, the RF cables and connectors are labeled as

MOD B TX0/RX0

and

MOD B TX1/RX1

.

Table 11

also shows which RF Module type can be installed in which PRU bay or bay combination.

The Single-Bay chassis is not included in Table 11 .

Page 18

©2015 TE Connectivity

FlexWave Prism Remote Unit RF Module Installation Guide

TECP-77-141 Issue 8 • 300001744178 Rev H • August 2015

Table 11. Supported Bay Use and RF Antenna Labels for Single-Card, Dual-Card, and HDM RF Modules

(From Top of Remote Unit Chassis Down)

Supported Bay

Configurations for Single-Bay

RF Modules

Supported Bay Combinations for Dual-Bay RF Modules

Supported

Bays in

Dual-Bay

Chassis

Supported

Bays in

Tri-Bay

Chassis

Supported

Bays in

Quad-Bay

Chassis

RF Module

Cable, RF

Module

Connector, and

Remote Antenna

Connector Label

Function

Bay D

Bay C

Bay B

Bay A

MOD D

MOD C

MOD B

MOD A

N/A

N/A

MOD B

N/A

MOD C

MOD B

MOD D

MOD B

Mod D TX0/RX0 Transmit RF power and primary/Path 1 receive to/from the antenna for RF Module D

Mod D TX1/RX1 Transmit RF power and secondary/Path 2 receive to/from the antenna for RF Module D

Mod C TX0/RX0 Transmit RF power and primary/Path 1 receive to/from the antenna for RF Module C

Mod C TX1/RX1 Diversity receive/Path 2 for Transmit RF power and secondary/Path 2 receive to/from the antenna for RF Module C

Mod B TX0/RX0 Transmit RF power and primary/Path 1receive to/from the antenna for RF Module B

Mod B TX1/RX1 Transmit RF power and secondary/Path 2 receive to/from the antenna for RF Module B

Mod A TX0/RX0 Transmit RF power and primary/Path 1 receive to/from the antenna for RF Module A

Mod A TX1/RX1 Transmit RF power and secondary/Path 2 receive to/from the antenna for RF Module A

FlexWave Prism Remote Unit RF Module Installation Guide

TECP-77-141 Issue 8 • 300001744178 Rev H • August 2015

Page 19

©2015 TE Connectivity

RF Module Cables and Supported Bay Installations for Legacy Dual-Bay 40W RF Modules

The cables and connectors have corresponding labels as shown in Table 12 for Legacy Dual-Bay 40W RF Modules.

Table 12

also shows which RF Module type can be installed in which PRU bay(s) when a 40W Dual-Bay RF Module is part of the RF Module mix in a PRU chassis. The Single-Bay chassis is not included in

Table 12 .

For Dual-Bay installations, the RF cables and connectors are labeled as

MOD N TX0/RX0

and

MOD N TX1/RX1

, where N refers to the top bay of the double-bay installation. For example:

For a Dual-Bay installation in a Quad-Bay chassis in which the RF Module is installed in the Bay D and Bay C combination, the RF cables and connectors are labeled as MOD D TX0/RX0 and MOD D TX1/RX1 .

For a Dual-Bay installation in a Tri-Bay chassis in which the RF Module is installed in the Bay C and Bay B combination, the RF cables and connectors are labeled as MOD C TX0/RX0 and MOD C TX1/RX1 .

Table 12. Supported Bay Assignments and RF Antenna Labels for Legacy Dual-Bay 40W RF Modules

(From Top of Remote Unit Chassis Down)

Supported Bay Combinations for Legacy 40W Dual-Bay RF Modules

Dual-Bay Tri-Bay Tri-Bay Quad-Bay

RF Module

Cable,

RF Module

Connector, and

Remote Antenna

Connector Label

Function

Bay D

Bay C

N/A N/A N/A

MOD D

MOD D

MOD C

Mod D TX0/RX0 Transmit RF power and primary/Path 1 receive to/from the antenna for RF Module D

Mod D TX1/RX1 Transmit RF power and secondary/Path 2 receive to/from the antenna for RF

Module D

Mod C TX0/RX0 Transmit RF power and primary/Path 1 receive to/from the antenna for RF Module C

N/A MOD C MOD C

Mod C TX1/RX1 Transmit RF power and secondary/Path 2 receive to/from the antenna for RF

Module C

Bay B

Bay A

MOD B MOD B

MOD C

MOD B MOD B

MOD B

Mod B TX0/RX0 Transmit RF power and primary/Path 1receive to/from the antenna for RF Module B

Mod B TX1/RX1 Transmit RF power and secondary/Path 2 receive to/from the antenna for RF

Module B

Mod A TX0/RX0 Transmit RF power and primary/Path 1 receive to/from the antenna for RF Module A

MOD A MOD A

Mod A TX1/RX1 Transmit RF power and secondary/Path 2 receive to/from the antenna for RF

Module A

Note: For Dual Module installations the center module shelf needs to be removed; see

“Dual-Bay Modules Only—Remove the Module Bay

Shelf” on page 25 .

Note: Install the Legacy Dual-Bay 40W RF Module in the lower-most bay in the chassis. If, however, if two Legacy Dual-Bay 40W RF Modules are present, install the 2100 Module in the lower-most Bay and the 1900 Module in the upper-most Bay.

Page 20

©2015 TE Connectivity

FlexWave Prism Remote Unit RF Module Installation Guide

TECP-77-141 Issue 8 • 300001744178 Rev H • August 2015

I

NSTALL THE

RF M

ODULE

(

S

)

The following sections guide you through the installation of an RF Module into a Remote Unit chassis. The process to install the four different types of RF Modules is basically the same; however, differences are noted and should be followed.

NOTE:

NOTE:

In the following steps, the RF cables and connectors are referred to as MOD N TX0/RX0 and as MOD N

TX1/RX1 where N equals A, B, C, or D.

When installing RF Modules, populate the RF Modules from highest frequency band to lowest within the

Remote Unit chassis. Likewise for power output, populate from the bottom bay to the top; higher output to lower output. That is, for a deployment with 2100 40W, 1900 40W, 850 20W and 700 20W

MIMO, install the RF Modules as follows:

• 2100 40W RF Module in Bay A

• 1900 40W RF Module in Bay B

• 850 20W RF Module in Bay C

• 700 20W MIMO RF Module in Bay D.

Safety Precautions

CAUTION! This is restricted access equipment and only qualified service personnel should service and operate this equipment using appropriate tools.

CAUTION! Wet conditions increase the potential for receiving an electrical shock when installing or using electrically-powered equipment. To prevent electrical shock, never install or use electrical equipment in a wet location or during a lightning storm.

CAUTION! Always allow sufficient fiber length to permit routing of patch cords and pigtails without severe bends.

Fiber optic patch cords or pigtails may be permanently damaged if bent or curved to a radius of less than

2 inches (5.1 cm).

CAUTION! Exterior surfaces of the Prism Remote Unit may be hot. Use caution during servicing.

CAUTION! Service personnel must confirm that the perimeter gasket and door-to-door gaskets are in place when closing the Remote Unit doors after servicing.

CAUTION! This equipment uses a Class 1 Laser according to FDA/CDRH rules. Laser radiation can seriously damage the retina of the eye. Do not look into the ends of any optical fiber. Do not look directly into the optical transceiver of any digital unit or exposure to laser radiation may result. An optical power meter should be used to verify active fibers. A protective cap or hood MUST be immediately placed over any radiating transceiver or optical fiber connector to avoid the potential of dangerous amounts of radiation exposure. This practice also prevents dirt particles from entering the adapter or connector.

CAUTION! This system is an RF Transmitter and continuously emits RF energy. Maintain 3 foot (91.4 cm) minimum clearance from the antenna while the system is operating. Wherever possible, shut down the RAN before servicing the antenna.

FlexWave Prism Remote Unit RF Module Installation Guide

TECP-77-141 Issue 8 • 300001744178 Rev H • August 2015

Page 21

©2015 TE Connectivity

Guard against Damage from Electro-Static Discharge

CAUTION! Electro-Static Discharge (ESD) can damage electronic components. To prevent ESD damage, always wear an ESD wrist strap when working with a Prism Remote Unit or when handling any of its components—including the RF Modules. Connect the ground wire on the ESD wrist strap to an earth ground source before touching the Prism Remote Unit or any of its components. Wear the wrist strap the entire time that you work with the Prism Remote Unit and its components.

CAUTION! Place Prism RF Modules in anti-static packing material when transporting or storing them.

Unpack and Inspect the RF Module

1 Inspect the exterior of the shipping container(s) for evidence of rough handling that may have damaged the components in the container.

2 Unpack each container while carefully checking the contents for damage and verify with the packing slip.

3

If damage is found or parts are missing, file a claim with the commercial carrier and notify TE Customer

Service (see “Contacting TE Connectivity” on page 51 ). Save the damaged cartons for inspection by the carrier.

4

Save all shipping containers for use if the equipment requires shipment at a future date.

CAUTION! Handle the RF Module with care during installation. Be especially careful to not damage the thermal-interface material (TIM), which is attached to the LPA, DARTs, and/or Motherboard with TX/RX boards. If the TIM is damaged, the LPA can overheat. Before installing the RF Module, check to see if the heatsink material is gouged or cracked. If the TIM is damaged, do not install the RF Module and contact

TE Connectivity for assistance (see

“Contacting TE Connectivity” on page 51

for contact information).

CAUTION! If the thermal-interface material is damaged, the installation and use of the RF Module may void the warranty of the RF Module.

Page 22

©2015 TE Connectivity

FlexWave Prism Remote Unit RF Module Installation Guide

TECP-77-141 Issue 8 • 300001744178 Rev H • August 2015

Remove Release Liners from the RF Module

NOTE: Release Liners are present on front and back of new modules.

1 Open the Remote Unit enclosure.

2

Remove release liners, if present, from the thermal pads on the RF Module prior to installing the module into the Remote Unit chassis.

CAUTION! The thermal pads are very sensitive to mishandling—do not nick, scratch, or ding them.

For Single- and Dual-Bay RF Modules, the thermal pads are located as listed below and as shown in

Figure 9 ,

which shows a Legacy Dual-Bay 40W RF Module.

• one large pad on the back surface of each Linear Power Amplifier (LPA)

• up to two on the front surface (DARTs)

• one on the left side for the (RDI)

• one on the vector modulator board

• one on the RF power combiner.

One thermal pad for each DART

One thermal pad for RF Power

Combiner

One thermal pad for Vector

Modulator

One thermal pad for each DART

One thermal pad for the RDI

One large thermal pad on each PA

(boom of the LPA)

Figure 9. Thermal Pads on a Legacy Dual-Bay 40W RF Module

FlexWave Prism Remote Unit RF Module Installation Guide

TECP-77-141 Issue 8 • 300001744178 Rev H • August 2015

Page 23

©2015 TE Connectivity

For HDM RF Modules, the thermal pads are located as listed below and as shown in Figure 10 .

• one pad for each Rx and Tx board

• one large pad over the DPM

• one for each Power Amplifier (PA), which is on the bottom of the HDM RF Module.

DPM Thermal Pad

Rx B Thermal Pad

Rx A Thermal Pad

Tx A Thermal Pad

Tx B Thermal Pad

NOTE: Tx and Rx cards are paired: Tx A ony pairs with Rx A and Tx B only pairs with Rx B.

Figure 10. Thermal Pads on an HDM RF Module

Check the DC Power Switch for the Module Bay

Ensure that the DC power switch that corresponds to the bay(s) in which the RF Module is to be installed is in the Off position (see graphic to the right).

DC Power switch for Bay D

DC Power switch for Bay C

DC Power switch for Bay B

DC Power switch for Bay A

Page 24

©2015 TE Connectivity

FlexWave Prism Remote Unit RF Module Installation Guide

TECP-77-141 Issue 8 • 300001744178 Rev H • August 2015

Dual-Bay Modules Only—Remove the Module Bay Shelf

1 FOR DUAL-BAY RF MODULES ONLY.

If you are installing a Dual-Bay RF Module, you must remove a module bay shelf from the PRU chassis to accommodate the module’s size.

(For further information, see Table 11 on page 19

.)

Remove the shelf as appropriate for the RF

Module:

• When installing in the A and B Bays, remove the Module B Bay Shelf.

• When installing in the C and D Bays, remove Module D Bay Shelf.

To remove a Module Bay Shelf: a Use a 9/64” Allen ™ wrench to remove the three screws that attach the module shelf to the PRU chassis, as shown in the following graphic.

b Discard or store the module shelf and fasteners.

Remove Module D Shelf for

Dual-Band Dual-Slot RF Modules

Use 9/64” Allen Wrench to remove the three module-shelf screws

Remove Module B Shelf for

Dual-Slot 40W RF Modules

FlexWave Prism Remote Unit RF Module Installation Guide

TECP-77-141 Issue 8 • 300001744178 Rev H • August 2015

Page 25

©2015 TE Connectivity

Install the RF Module into the Prism Remote Chassis

1 Hold the RF Module so that the DART card(s) face away from the PRU and the Mounting Hook is toward the

Receiving flange on the PRU chassis.

NOTE: Always install RF Modules from the bottom up. Do not skip a bay, as this provides more efficient heat dissipation.

2 Holding the RF Module at a 45° angle in respect to the rear heatsink, rest the bottom surface of the module on the RF Module shelf, as shown in one of the following graphics, and as applicable to the RF Module.

Single-Bay RF Module: Figure 11 on page 26

HDM RF Module: Figure 12 on page 27

Dual-Bay RF Module: Figure 13 on Page 28

Legacy Dual-Bay 40W RF Module: Figure 14 on Page 29 .

Heat Sink

Bay D

Bay C

Bay B

Bay A

SeRF

Module

Single-Slot

RF Module

Page 26

©2015 TE Connectivity

Figure 11. Installing a Single-Bay RF Module

FlexWave Prism Remote Unit RF Module Installation Guide

TECP-77-141 Issue 8 • 300001744178 Rev H • August 2015

Bay D

Bay C

Bay B

Bay A

SeRF Module

Figure 12. Installing an HDM RF Module

HDM RF Module

FlexWave Prism Remote Unit RF Module Installation Guide

TECP-77-141 Issue 8 • 300001744178 Rev H • August 2015

Page 27

©2015 TE Connectivity

Installing a Dual-Band

Dual-Slot RF Module

Figure 13. Installing a Dual-Bay RF Module

Page 28

©2015 TE Connectivity

FlexWave Prism Remote Unit RF Module Installation Guide

TECP-77-141 Issue 8 • 300001744178 Rev H • August 2015

Figure 14. Installing a Legacy Dual-Bay 40W RF Module

FlexWave Prism Remote Unit RF Module Installation Guide

TECP-77-141 Issue 8 • 300001744178 Rev H • August 2015

Page 29

©2015 TE Connectivity

3 Align the Mounting Hook on the module with the receiving flange on the PRU heat sink, and then slide the RF

Module in toward the flange until it can go no further.

RF Module

Mounng hook

Mounng Bracket at back of the PRU

Chassis

Receiving flange

(View is looking down into the

PRU chassis from the top.)

4

Push the left edge of the RF Module back and into the PRU chassis until it can go no further, as shown in the following graphics:

For Single-Bay RF Modules, see Figure 15 on page 31

.

For HDM RF Modules, see Figure 16 on page 32

.

For Dual-Bay RF Modules, see Figure 17 on page 33

, which uses the Legacy Dual-Bay 40W RF Module as an example.

CAUTION! Make sure the RF Module is seated correctly in the Module shelf. Incorrect alignment of the RF Module can cause the RF Module to fail due to overheating.

• The front edge of the RF Module should be parallel with the shelf above it.

• The Mounting Hook on the RF Module should be fully engaged with the Receiving flange on the

Remote Unit chassis.

• An incorrectly seated RF Module makes closing the Prism door difficult. If you later cannot shut the

Remote Unit door, verify that the RF Module is installed correctly.

Page 30

©2015 TE Connectivity

FlexWave Prism Remote Unit RF Module Installation Guide

TECP-77-141 Issue 8 • 300001744178 Rev H • August 2015

Single-Slot

RF Module

Push the RF Module back into the chassis unl it can go no further.

Figure 15. Seating a Single-Bay RF Module

FlexWave Prism Remote Unit RF Module Installation Guide

TECP-77-141 Issue 8 • 300001744178 Rev H • August 2015

Page 31

©2015 TE Connectivity

Page 32

©2015 TE Connectivity

HDM

RF Module

Push the HDM RF Module back into the chassis unl it can go no further.

Figure 16. Seating an HDM RF Module

FlexWave Prism Remote Unit RF Module Installation Guide

TECP-77-141 Issue 8 • 300001744178 Rev H • August 2015

Push the RF Module back into the chassis unl it can go no further.

Figure 17. Seating a Dual-Bay RF Module

FlexWave Prism Remote Unit RF Module Installation Guide

TECP-77-141 Issue 8 • 300001744178 Rev H • August 2015

Page 33

©2015 TE Connectivity

Secure RF Module Latches

1 To secure the module latches on the left side of the RF Module, do one of the following, as appropriate for the

RF Module being installed:

“Connect Latches on Single-Bay and HDM RF Modules” on page 34

“Connect Latches on Dual-Bay RF Modules” on page 35

.

Connect Latches on Single-Bay and HDM RF Modules

For Single-Bay and HDM RF Modules, secure two latches, as shown in

Figure 18

.

Two latches on Single-Slot

RF Modules

Two latches on

HDM RF Modules

Page 34

©2015 TE Connectivity

Figure 18. Latches on Single-Bay and HDM RF Modules

FlexWave Prism Remote Unit RF Module Installation Guide

TECP-77-141 Issue 8 • 300001744178 Rev H • August 2015

Connect Latches on Dual-Bay RF Modules

For Dual-Bay RF Modules, secure four latches, as shown in

Figure 19 .

Four latches in a

Dual-Band Dual-Slot

RF Module

Figure 19. Dual-Bay RF Module Latches

FlexWave Prism Remote Unit RF Module Installation Guide

TECP-77-141 Issue 8 • 300001744178 Rev H • August 2015

Page 35

©2015 TE Connectivity

Latches on Legacy Dual-Bay 40W RF Modules

For Legacy Dual-Bay 40W RF Modules, secure four latches, as shown in Figure 20 .

Four latches in a

Legacy Dual-Slot 40W

RF Module

Figure 20. Legacy Dual-Bay 40W RF Module Latches

Verify that the RF Module Mounting Hook is Engaged

Verify that the RF Module Mounting Hook is engaged correctly by pulling the module away from the heat sink.

The RF Module should not move. If the RF Module moves during this check, repeat all the steps starting at “Install the RF Module into the Prism Remote Chassis” on page 26

through this step.

Connect the RF Module Cables to the PRU Chassis

The steps to connect the RF Module cables have been separated into two different procedures; follow the steps that correspond to the RF Module being installed.

“Connecting Cables in a Single-Bay RF Module Installation” on page 37

“Connecting Cables in a Dual-Bay RF Module Installation” on page 40 .

Page 36

©2015 TE Connectivity

FlexWave Prism Remote Unit RF Module Installation Guide

TECP-77-141 Issue 8 • 300001744178 Rev H • August 2015

Connecting Cables in a Single-Bay RF Module Installation

1

Position the cables so that they are under the right edge of the RF Module, pointing up.

2 Follow the rules listed in

“Understanding RF Cable Rules” on page 18 .

3

Connect the RF Module cables, in the order shown below. As you work, refer to the graphic that corresponds to the RF Module being installed into a single bay of the PRU: for a Single-Bay RF Module, refer to

Figure 21 on page 38 , and for an HDM RF Module, refer to

Figure 22 on page 39 and Table 13 on page 39 .

a Connect the MOD N TX0/RX0 cable to the RF Module (the RF cables and connectors are referred to as

MOD N TX0/RX0 where N equals A , B , C , or D ).

i Insert the N-Style Plug of the MOD N TX0/RX0 cable into the TX0/RX0 N-Style Jack of the RF Module.

ii

Turn the coupling nut of the plug clockwise to thread onto the jack and finger-tighten.

iii Torque coupling nut to 8 ±1 in-lbs to ensure full connection.

NOTE: Insufficient torque applied to RF Module connections can result in elevated insertion/return loss and higher than normal VSWR reported by the system.

b

Connect the MOD N TX1/RX1 cable to the RF Module (the RF cables and connectors are referred to as

MOD N TX1/RX1 where N equals B , C , or D ).

i

If a TX1/RX1 RF Module connection is available, insert the N-Style Plug of the MOD N TX1/RX1 cable into the TX1/RX1 N-Style Jack of the RF Module. If RF Module connection is not available, constrain the MOD N TX1/RX1 cable to accompanying cables using a tie wrap so it cannot be pinched or prevent the Remote Unit door from closing.

ii

Turn the coupling nut of the plug clockwise to thread onto the jack and finger-tighten.

iii Torque coupling nut to 8 ±1 in-lbs to ensure full connection.

NOTE: Insufficient torque applied to RF Module connections can result in elevated insertion/return loss and higher than normal VSWR reported by the system.

c

Connect the LVDS Cables to the RF Module—the LVDS cables labeled PRIM and DIV should always either be connected to a RF Module or strain relieved to adjacent cables, as this protects the cable against damage through misplacement. Maintain adequate strain-relief distances from the connection points to the RF Module.

i

Connect the MOD N DIV LVDS Cable to the DIV receptacle of the RF Module by inserting and sliding in until fully seated. Full insertion can be recognized by an audible click as the LVDS Cable Connector locks into the RF Module Receptacle.

ii Connect the MOD N PRIM LVDS Cable to the PRIM connector, following the same steps as above. Full insertion can be recognized by an audible click as the LVDS Cable Connector locks into the RF Module

Receptacle.

iii

Ensure the two LVDS cables are fully seated and latched into their respective receptacles on the RF

Module by lightly pulling outward on the connectors. If fully seated and locked into position, the cable connectors will not slide back out.

FlexWave Prism Remote Unit RF Module Installation Guide

TECP-77-141 Issue 8 • 300001744178 Rev H • August 2015

Page 37

©2015 TE Connectivity

d Connect the Power cable to the PWR receptacle of the RF Module.

i

Ensure that the DC power switch that corresponds to the bay(s) in which the RF Module is to be

installed is in the Off position (see “Check the DC Power Switch for the Module Bay” on page 24

).

i

Insert the Power cable into the PWR connector, and slide it in until fully seated. Full insertion can be recognized by an audible click as the Power cable Connector locks into the RF Module Receptacle. ii

Verify that the Power cable is fully seated by lightly pulling back on it while making sure to not depress the release triggers on the ends of the connector. When fully inserted, the cable should not be able to be removed from the receptacle.

4 Repeat all the steps in

“Install the RF Module(s)” on page 21

to install other RF Modules.

Cable connecons for a Single-Slot RF Module

Bay D

Bay C

PWR

PRIM

DIV

TX0/RX0

TX1/RX1

Bay B

Bay A

SeRF

Module

Page 38

©2015 TE Connectivity

Edge of Connector Interface Panel

Figure 21. Cable Connections for Single-Bay RF Modules

Note roung of high-speed cables

Note bend radii ≥ 1-inch

FlexWave Prism Remote Unit RF Module Installation Guide

TECP-77-141 Issue 8 • 300001744178 Rev H • August 2015

CAUTION! Ensure that all cable bends are below the top edge of the Connector Interface Panel as indicated by the dashed line in the preceding figure. Failure to correctly position the cables could inhibit closing the

Remote Unit door, which can result in damage to the cables.

Cable Connecons for an HDM RF Module

DATA 0 (PRIM)

DATA 1 (DIV)

POWER

Cable Connecon Notes

• Always connect the Power cable.

• Always connect the two LVDS cables: PRIM and DIV.

• SISO requires one RF cable (TX0/RX0).

• MIMO and Dual-Band require two RF cables

(TX1/RX1 and TX0/RX0).

TX1/RX1

TX0/RX0

Figure 22. Cable Connections for HDM RF Modules

Table 13

lists how to correctly connect HDM RF Modules to the Antenna ports on the bottom of the Remote Unit.

Table 13. HDM Antenna Port Mapping

RF Module Catalog # Description TX0/RX0 TX1/RX1

FWP-L4MT000MOD

FWP-U4MT000MOD

FW P-L4MTU4MMOD

FWP-44MT000MOD

FWP-441T841M OD (1)

FWP-B4MT000MOD

FWP-C4MT000MOD

FWP-84MT000MOD

FWP-84MTA4M MOD

20W 700 lABC Module, MIMO HDM, Single-Bay

20W 700 uC Module, MIMO HDM, Single-Bay

20W 700 lABC/700uC, Dual, Single-Bay

Path 1

Path 1

Path 2

Path 2

700 lABC 700 uC

20W 800 MIMO, Single Bay, with two External Filters Path 1

20W 800 SMR/ 1900 PCS, Dual RF Module 1900

20W 850 DUAL, MIMO, Single Bay

20W 850 Cell/1900 PCS, Dual, Single-Bay

20W 1900 PCS Dual MIMO, Single-Bay

20W 1900/2100 Dual, Single Bay

Path 1

1900

Path 1

2100

Path 2

800

Path 2

850

Path 2

1900

F W P - A 4 M T 0 00 M O D 20W HDM AWS Band 4 MIMO, Single-Bay Path 1 Path 2

(1) A 20W 800 SMR/ 1900 PCS, Dual RF Module RF Module (FWP-441T841MOD) requires a FlexWave Notch

Filter (FWP-SPRINTFILTER) between the Remote Unit and the antenna to provide protection from spurious emissions in the Public Safety band below 861.35 MHz and the Cellular band above 869.5 MHz. Information

on how to install the Notch Filter is provided in “FlexWave Notch Filter (FWP-SPRINTFILTER)” on page 47

.

FlexWave Prism Remote Unit RF Module Installation Guide

TECP-77-141 Issue 8 • 300001744178 Rev H • August 2015

Page 39

©2015 TE Connectivity

Connecting Cables in a Dual-Bay RF Module Installation

1

Position the cables so that they are under the right edge of the RF Module, pointing up.

2 Follow the rules listed in

“Understanding RF Cable Rules” on page 18 .

3

Working from the bottom connector up, connect the RF Module cables, as described below. As you work, refer to the graphic that corresponds to the RF Module being installed in the Dual-Bay: for a Dual-Bay RF Module, refer to

Figure 23 on Page 42

, and for a Legacy Dual-Bay 40W RF Module, refer to Figure 24 on Page 43

.

a Connect the MOD N TX1/RX1 cable to the N-Style RF connector on the Dual-Bay RF Module (the RF cables and connectors are referred to as MOD N TX1/RX1 where N equals B , C , or D ).

i Constrain the MOD N TX1/RX1 cable of the lower RF Module bay to accompanying cables using a tie wrap so it cannot be pinched or prevent the Remote Unit door from closing.

ii Connect the MOD N TX1/RX1 cable to the TX1/RX1 N-Style Jack of the upper RF Module Bay.

iii

Turn the coupling nut of the plug clockwise to thread onto the jack and finger-tighten.

iv Torque coupling nut to 8 ±1 in-lbs to ensure full connection.

NOTE: Insufficient torque applied to RF Module connections can result in elevated insertion/return loss and higher than normal VSWR reported by the system.

b

Connect the MOD N TX0/RX0 cable to the RF Module (the RF cables and connectors are referred to as

MOD N TX0/RX0 where N equals A , B , C , or D ).

i

Insert the N-Style Plug of the MOD N TX0/RX0 cable into the TX0/RX0 N-Style Jack of the lower RF

Module bay. If RF Module connection is not available, constrain the MOD N TX0/RX0 cable to accompanying cables using a tie wrap so it cannot be pinched or prevent the Remote Unit door from closing.

ii

Turn the coupling nut of the plug clockwise to thread onto the jack and finger-tighten.

iii Torque coupling nut to 8 ±1 in-lbs to ensure full connection.

NOTE: Insufficient torque applied to RF Module connections can result in elevated insertion/return loss and higher than normal VSWR reported by the system.

c

Connect the LVDS Cables to the RF Module.

i If available, connect the MOD N DIV LVDS Cable to the DIV receptacle of the lower RF Module by inserting and sliding in until fully seated. If DIV receptacle is not available, constrain the MOD N DIV

LVDS Cable to accompanying cables using a tie wrap so it cannot be pinched or prevent the Remote

Unit door from closing. Full insertion can be recognized by an audible click as the LVDS Cable

Connector locks into the RF Module Receptacle.

ii

Connect the MOD N DIV LVDS Cable to the DIV receptacle of the upper RF Module by inserting and sliding in until fully seated. If DIV receptacle is not available, constrain the MOD N DIV LVDS Cable to accompanying cables using a tie wrap so it cannot be pinched or prevent the Remote Unit door from closing. Full insertion can be recognized by an audible click as the LVDS Cable Connector locks into the RF Module Receptacle.

Page 40

©2015 TE Connectivity

FlexWave Prism Remote Unit RF Module Installation Guide

TECP-77-141 Issue 8 • 300001744178 Rev H • August 2015

iii If available, connect the MOD N PRIM LVDS Cable to the PRIM receptacle of the upper RF Module by inserting and sliding in until fully seated. If DIV receptacle is not available, constrain the N PRIM LVDS

Cable to accompanying cables using a tie wrap so it cannot be pinched or prevent the Remote Unit door from closing.

iv Ensure the two LVDS cables are fully seated and latched into their respective receptacles on the RF

Module by lightly pulling outward on the connectors. If fully seated and locked into position, the cable connectors will not slide back out.

d

Connect the Power cable to the PWR receptacle of the RF Module.

i Ensure that the DC power switch that corresponds to the bay(s) in which the RF Module is to be installed is in the Off position (see

“Check the DC Power Switch for the Module Bay” on page 24

).

ii Insert the Power cable into the PWR receptacle of the lower RF Module bay, and slide it in until fully seated. Full insertion can be recognized by an audible click as the Power cable Connector locks into the RF Module Receptacle. i

Insert the Power cable into the PWR receptacle of the upper RF Module bay, and slide it in until fully seated. Full insertion can be recognized by an audible click as the Power cable Connector locks into the RF Module Receptacle. If the PWR receptacle is not available, constrain the Power cable to accompanying cables using a tie wrap so it cannot be pinched or prevent the Remote Unit door from closing.

ii Verify that the Power cable is fully seated by lightly pulling back on it while making sure to not depress the release triggers on the ends of the connector. When fully inserted, the cable should not be able to be removed from the receptacle.

4

Repeat all the steps in

“Install the RF Module(s)” on page 21

to install other RF Modules.

FlexWave Prism Remote Unit RF Module Installation Guide

TECP-77-141 Issue 8 • 300001744178 Rev H • August 2015

Page 41

©2015 TE Connectivity

Page 42

©2015 TE Connectivity

Cable Connecons for a Dual-Slot RF Module

Tie wrap

Two N-Type

RF connectors

Factory-installed

RX1 cable

N-Type

RF connector

Figure 23. Cable Connections for Dual-Band Dual-Bay RF Modules

FlexWave Prism Remote Unit RF Module Installation Guide

TECP-77-141 Issue 8 • 300001744178 Rev H • August 2015

Keep cable bends behind the edge of the Connector

Interface Panel

Tie wrap around factory-installed

RX1 cable

Figure 24. Cable Connections for Legacy Dual-Bay 40W RF Modules

CAUTION! Ensure that all cable bends are below the top edge of the Connector Interface Panel as indicated by the dashed line in the preceding figure. Failure to correctly position the cables could inhibit closing the

Remote Unit door, which can result in damage to the cables.

FlexWave Prism Remote Unit RF Module Installation Guide

TECP-77-141 Issue 8 • 300001744178 Rev H • August 2015

Page 43

©2015 TE Connectivity

Power on the RF Module(s) and the Prism Remote Unit

1 If necessary, power up the Remote Unit by turning its AC or DC power switch to On.

2

Ensure that the external Status LED on the bottom of the Remote Unit goes off.

NOTE: During bootup, this LED will be red. After approximately one minute, the LED should extinguish.

Status LED

POWER

48VDC/XXA

NETWORK

MOD D

TX1/RX1

MOD D

TX0/RX0

MOD D

TX1/RX1

MOD D

TX0/RX0

NETWORK

POWER

100-240 VAC

50-60 Hz

XX AMPS

WARNING:

HIGH LEAKAGE CURRENT. EARTH

CONNECTION ESSENTIAL BEFORE

CONNECTING SUPPLY

NOTE:

Boom of an AC-Powered PRU Boom of a DC-Powered PRU

The preceding graphic illustrates the Status LED on a Quad-Bay PRU. The Status LED for the Single-Bay,

Dual-Bay, and Tri-Bay PRUs is in the same location and functions the same as the Status LED for the

Quad-Bay PRU.

Page 44

©2015 TE Connectivity

FlexWave Prism Remote Unit RF Module Installation Guide

TECP-77-141 Issue 8 • 300001744178 Rev H • August 2015

3 Follow the rules listed below to toggle the Power switch that corresponds to each RF Module to its ON position.

• For Dual-Band Dual-Bay RF Modules, use the Power switch for the lower module. For example, to power up a Dual-Bay RF Module in combined bays C+D in a Quad-Bay chassis, turn ON DC Power switch for Mod

C; leave the DC Power switch for Mod D OFF.

A Legacy Dual-Bay 40W RF Module uses the Power Supplies in both bays. If the Legacy Dual-Bay 40W RF

Module is installed in bays C+D, turn ON the Power switch for Mod C and Mod D.

SeRF

Module

AC/DC Power switch for

PRU chassis

Bay D

Bay C

Bay B

Bay A

DC Power switch for Bay D

DC Power switch for Bay C

DC Power switch for Bay B

DC Power switch for Bay A

4 Verify that the LEDs for all installed RF Modules (located next to their respective connectors) are green. If any of the RF Module LEDs are not green, verify that each RF Module cable is seated fully in its respective connector. If after checking the cable connections and an LED is not green, contact TE for assistance (see

“Contacting TE Connectivity” on page 51 ).

FlexWave Prism Remote Unit RF Module Installation Guide

TECP-77-141 Issue 8 • 300001744178 Rev H • August 2015

Page 45

©2015 TE Connectivity

Close the Remote Unit Door and Solar Shield

1 Do not slam the door to close it—gently swing the door shut and press it firmly closed.

2

Slowly close each door latch in a smooth fluid motion—do not allow the door latches to snap closed. For best results, starting with the top latch and working down to the bottom latch, use a flat-head screwdriver to close each latch as shown below.

3 Do not slam the Solar Shield to close it—gently swing it shut and press it firmly closed.

Door latch

Solar Shield Door

CAUTION! Service personnel must confirm that the perimeter gasket and door-to-door gaskets are in place when closing the Remote Unit doors after servicing.

CAUTION! If the PRU door was allowed to snap closed, RF output from an HDM RF Module may be disabled for up to three minutes. Any alarms generated immediately following the opening/closing of the PRU Doors, such as Door Open, RF Power Low, System VSWR Fault, and LPA VSWR Fault, automatically clear once the RF has recovered. If alarms do not clear after three minutes, please contact TE for technical support;

see “Contacting TE Connectivity” on page 51

.

Provision the Prism Remote Unit

Refer to the current EMS System Setup and Provisioning Guide for information on configuring the PRU for a

FlexWave Prism system.

Page 46

©2015 TE Connectivity

FlexWave Prism Remote Unit RF Module Installation Guide

TECP-77-141 Issue 8 • 300001744178 Rev H • August 2015

F

LEX

W

AVE

N

OTCH

F

ILTER

(FWP-SPRINTFILTER)

A FlexWave Notch Filter (FWP-SPRINTFILTER) ships with and is required in installations of the following RF

Modules:

• 20W 800 SMR/ 1900 PCS, Dual RF Module (FWP-441T841MOD)

20W 800 MIMO, Single Bay, with two External Filters (FWP-44MT000MOD).

Notch Filter Installation Tips

You install the Notch Filter between the Prism Remote Unit and the antenna to provide protection from spurious emissions in the Public Safety band below 861.35 MHz and the Cellular band above 869.0 MHz.

The following are installation tips for the Notch Filter:

• You can use the same mounting method to mount the Notch Filter as you used to mount the Remote Unit.

Mount the Notch Filter vertically with the N-type female connectors at the bottom.

• There are two Ground lugs on the Notch Filter, which are on the back of the two mounting brackets. Follow local practice to ground the Notch Filter.

Figure 25

provides the dimensions required to create a mounting template.

Mounng

Bracket

2 Locaons

5/16-18

Ground Lug

2.805

.95

1.00

.95

.70

15.93

17.9 ±.1

16.0 ±.1

8.51

Front View

.70

Back View

Figure 25. Notch Filter Mounting Dimensions

4.10

4.55

Side View

Mounng

Bracket

FlexWave Prism Remote Unit RF Module Installation Guide

TECP-77-141 Issue 8 • 300001744178 Rev H • August 2015

Page 47

©2015 TE Connectivity

Figure 26 illustrates how to pole mount the Notch Filter.

1.13

3.81

Boom View of

Notch Filter

Output

N-Type

Female

Connector

Input

N-Type

Female

Connector

NOTE: The 800 Notch Filter is designed to accept input from the PRU in either its

Output or Input port, as well as the feed from the antenna.

Mounng Bracket

Band must be long enough to wrap around the pole

Hose clamp sized for installaon requirement

Figure 26. Pole Mounting a Notch Filter

Notch Filter Specifications

Frequency Range (MHz)

RF Connectors

Maximum Emissions (Sprint requirement) per 30 kHz

817-824 —

< 854 < -76 dBm

854-859 < -76 dBm

859-861.35 < -76 dBm

Enclosure Rating

861.35-861.5 < -56 dBm

861.5-861.6 < -42 dBm

862-869 —

IP67

N-Type Connector, Female (2)

Ground Studs (w/star washer)

All ground Studs must accept AWG 6 wire

Mounting

Strap mount (Vertical and Horizontal) on up to 12" pole, or Wall mount

Size

15.93" x 8.51" x 4.10"

Weight

18 LBS

Operational Temperature

-25°C to +65°C

Humidity

ETSI 300-019-1-3 10%-100% Condensing

Vibration-operation

ETSI 300-019-1-4

Vibration-transportation

ETSI 300-019-1-2

Page 48

©2015 TE Connectivity

FlexWave Prism Remote Unit RF Module Installation Guide

TECP-77-141 Issue 8 • 300001744178 Rev H • August 2015

S

TANDARDS

C

ERTIFICATION

FCC

This equipment complies with the applicable sections of Title 47 CFR Part 15 (Host Unit), Part 22 (800 MHz Cellular), Part

24 (1900 MHz - PCS), Part 90 (800/900 - SMR), and Part 27 (2100 MHz - AWS, 700 MHz -LTE and 2300 MHz - WCS).

WARNING.

This is NOT a CONSUMER device. It is designated for installation by FCC LICENSEES and QUALIFIED

INSTALLERS. You MUST have an FCC LICENSE or express Consent of an FCC Licensee to operate this device. Unauthorized use may result in Significant forfeiture penalties, including penalties in excess of $100,000 for each continuing violation.

IC

This equipment complies with the applicable sections of RSS-131- Zone Enhancers for the Land Mobile Service. The term

“IC:” before the radio certification number only signifies that Industry Canada Technical Specifications were met.

The Manufacturer's rated output power of this equipment is for single carrier operation. For situations when multiple carrier signals are present, the rating would have to be reduced by 3.5 dB, especially where the output signal is re-radiated and can cause interference to adjacent band users. This power reduction is to be by means of input power or gain reduction and not by an attenuator at the output of the device.

Note: To comply with Maximum Permissible Exposure (MPE) requirements, the maximum composite output from the antenna cannot exceed 1000 Watts ERP (LTE, Cellular and SMR), the antenna cannot exceed 1640 Watts EIRP (PCS and

AWS), and the antenna must be permanently installed in a fixed location that provides at least 6 meters (20 feet) of separation from all persons.

UL/CUL

This will be installed in a restricted access location. This equipment complies with Type 4, per UL and CUL 50, Standard for

Enclosures for Electrical Equipment. This equipment provides the degree of protection specified by IPX6 as defined in IEC

Publication 529.

FDA/CDRH

This equipment uses a Class 1 LASER according to FDA/CDRH Rules. This product conforms to all applicable standards of

21 CFR Part 1040.

Caution: Modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.

EU Harmonized Standards

Meets essential requirements of R&TTE 1999/5/EC.

• Article 3.1a—The protection of the health and the safety of the user and any other person, including the objectives with respect to safety requirements contained in Directive 2006/95/EC, but with no voltage limit applying.

• Article 3.1b—The protection requirements with respect to electromagnetic compatibility contained in Directive

2004/108/EC.

• Article 3.2—In addition, radio equipment shall be so constructed that it effectively uses the spectrum allocated to terrestrial/space radio communication and orbital resources so as to avoid harmful interference.

EMC Standards

EN 55022 and EN55024 (CE marked)

Safety Standards

This equipment complies with IEC 60950-1, 2ND Edition + Amendment 1 (CE marked) and with UL 60950-1, 2ND Edition +

Amendment 1 (File number E174166) (USA and Canada)

FlexWave Prism Remote Unit RF Module Installation Guide

TECP-77-141 Issue 8 • 300001744178 Rev H • August 2015

Page 49

©2015 TE Connectivity

A

CCESSING

U

SER

D

OCUMENTATION ON THE

TE C

USTOMER

P

ORTAL

You can access additional user documentation on the TE Customer Portal, as described below.

1 Click on the following URL link: https://www.te.com/portal/wireless/

(Alternatively, enter the preceding URL into your web browser, and then press E NTER

on your keyboard.)

2

Access to the Customer Portal requires a user account and password. On the

Sign In

page, do one of the following:

If you have an account, in the

Already Registered? Sign In Now

panel, enter your

Email

and

Password

, and then click Sign In .

If you don’t have an account, under

Create an Account

, click

Register Now

and follow the prompts.

3 On the Wireless Customer Portal home page, in either the Resources or Documents panel, click the Manuals and Data Sheets

link.

4 On the Manuals and Data Sheets page, do the following: a

Open the folder for the product line that corresponds to the document that you want to access.

b Click on the title of the manual that you wish to open.

c

(Optional) Save the PDF to your computer.

Page 50

©2015 TE Connectivity

FlexWave Prism Remote Unit RF Module Installation Guide

TECP-77-141 Issue 8 • 300001744178 Rev H • August 2015

C

ONTACTING

TE C

ONNECTIVITY

Telephone Numbers

Sales

Asia Pacific

France

Germany

Italy

Spain

United Kingdom

USA or Canada

Extension

Connectivity Extension

Wireless Extension

+65-6294-9948

0800 914032

0180 2232923

0800 782374

900 983291

0800 960236

1-800-366-3891

73000

73475

73476

Technical Support

USA or Canada

Elsewhere

1-800-530-9960

+1-952-917-0761

Online Access

Customer Portal https://www.te.com/portal/wireless/

Technical Support for Wireless Products http://www.te.com/WirelessSupport

FlexWave Prism Remote Unit RF Module Installation Guide

TECP-77-141 Issue 8 • 300001744178 Rev H • August 2015

Page 51

©2015 TE Connectivity

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement

Table of contents