Checkpoint Counterpoint iD Quick Start Guide
Checkpoint Systems DO4CPID is a technologically advanced deactivation system for Checkpoint's Evolve and VisiPlus EAS labels and tags. It offers retailers a simple, reliable, and cost-effective solution for EAS deactivation at the point of sale. DO4CPID features multiple deactivation zones for wide coverage, high-speed deactivation, and automatic tuning for optimal performance. Its compact design and easy installation make it suitable for various retail environments, enhancing customer experience and reducing false alarms.
Publicité
Publicité
CKP P/N 10073883
Counterpoint iD
Quick Start Guide
Reference During Installation
CPiD - Quick Start Guide
Copyright © 2014 by Checkpoint Systems, Inc. All rights reserved.
Checkpoint® is a registered trademark of Checkpoint Systems, Inc.
Released March 21, 2014.
Published by:
Checkpoint Systems Inc.
101 Wolf Drive
Thorofare, NJ 08086
For use with Checkpoint’s Counterpoint Intelligent Deactivation System.
Checkpoint, Counterpoint, Evolve, VisiPlus and People Counter are registered trademarks of Checkpoint Systems, Inc.
All rights reserved. Information in this document is subject to change without notice.
Companies, names and data used in examples herein are fictitious unless otherwise noted.
No part of the contents of this book may be reproduced or transmitted in any form or by any means without the written permission of the publisher.
All other product or service names are the property of their respective owners.
Document Revision Information
Part Number: 10073883
Rev
00
Description
CR2642B
Date
March 21, 2014
Authors
G. Plizak, B. Langer, R. Decker
Quick Start Guide: Counterpoint iD
Installation Requirements
What’s In The Box
1 CPiD Chassis
1 Power Supply Unit (PSU)
Install kit including:
2 #8 hex head screws (5/8 inch long)
2 tie wraps
1 6-Pin connector
Tools Required
1 small flathead screwdriver
1 1/4 inch nut driver
Optional
DMS Version 1.8.95 or later (required for setup of advanced features)
Operation/Features
Front
3
4
5
1
2
6
Sounder
Status LED
Power LED (Green only)
Volume Knob
Latch
Rubber Boot
Page 1 of 7
Sounder for alarm annunciation
Informs the User about device status. LED Functions are defined in the label underneath the top plate.
Indicates power
Adjusts sounder volume
Allows user to remove unit for installing external connections
(e.g., cable for Antenna Pad, key switch or lock/trigger)
Conceals DIP Switches, Reset Button and DMS Connection port
Rear
Checkpoint Systems, Inc.
– Field Service Installation Document – CKP P/N 10073883
3
4
1
2
Inside
Input Power Connector
DC Jack Strain Relief
Internal Cabling exit
USB Connector
Connector for +12V DC input power
Strain relief for power cord
Opening for all cables that connect internally (e.g., Antenna Cable)
Connector for future USB functionality
This is what you find, pre-install with chassis cover (plate) removed.
1 Antenna 1 and 2
2 Antenna 3
Primary RF Connection for 2 antennas max. (parallel)
Pin-out 1 ANT2+
4
5
2
3
GND
ANT2-
ANT1+
GND
6 ANT1-
Secondary RF Connection for another supported antenna
Pin-out 1
2
ANT3+
GND
3 ANT3-
Page 2 of 7
Quick Start Guide: Counterpoint iD
3
4
Alarm and Interlock
+12V Auxiliary Output and GPIO
Connection for Interlock and Alarm
Interlock Description / Pin-out
Interlocks are external devices that relay control signals to the device
1
2
3
4
Interlock Input. Default is shorted to Pin 2 using wire jumper
GND
Interlock Opto, polarity independent (jumper must be removed prior to use).
Interlock Opto, polarity independent (jumper must be removed prior to use)
Alarm Description / Pin-out
The alarm output supports generic sounder devices and external LEDs
5
6
+12V
Alarm -
Connection for GPIO and +12V output
GPIO Description / Pin-out
General Purpose
Input Output
1
2
3
4
+12V Description / Pin-out
This set of terminal pins is used to connect devices that require 12V
5
6
GPO RLY, 1A max resistive load
GPO RLY, 1A max resistive load
GPI+, 3.3V through 10k Ohm
GND
+12V, 100mA max
GND
DIP Switch Functions
Selection Switch 1 Selection
High Power OFF Mode 5
Low Power ON Mode 6
Mode 4
Verification
Switch 2 Switch 3 Selection Switch 4 Switch 5 Switch 6
OFF OFF Min Gain OFF OFF OFF
ON
OFF
ON
ON
Gain 2
Gain 3
OFF
OFF
OFF
ON
ON
OFF
ON OFF Gain 4
Gain 5
Gain 6
Gain 7
OFF
ON
ON
ON
ON
OFF
OFF
ON
ON
OFF
ON
OFF
Max Gain ON ON ON
Page 3 of 7
Checkpoint Systems, Inc.
– Field Service Installation Document – CKP P/N 10073883
Status LED Functions
Status LED Function
Detection (Tag Alarm)
Waiting for Interlock
Keyswitch disabled
AutoTune
Auto Tune Window
Red
X
Yellow
X
X
Blink
Blue Teal White Violet
0.5s after reset is pressed
Green
X Auto Tune Error
Antenna Overvoltage
Mistuned
Verification Mode
Mode 4
Mode 5
Mode 6
Factory Default Settings
*Future Release
Blink
Blink Blink
X
Blink at power up
X*
X*
X*
Reset Button
This button resets the unit and auto-tunes the antenna under certain conditions. See
DMS Setup
Some features of CPiD are able to adjusted / applied without DMS, others are not. For example, DMS is required to enable the secondary transmitter.
( Click here for FSWP link. Download DMS Version 1.8.95 or later.)
GPIO
The default system configuration has the following GPIO functions:
• GPO – Primary Alarm Relay
• GPI – Disabled
Any other functionality needs require DMS.
Page 4 of 7
Quick Start Guide: Counterpoint iD
Mounting
A secure location, such as behind an access door below the register, is ideal for mounting. Plan routing and location so the unit will not be struck by anything.
When possible, locate unit such that user has ability to interface with device.
Consult the SOW when provided. Customer may prefer / request no access.
Volume can only be muted in DMS. Choose 1 of the following orientations:
Figure 1: Typical Orientations
Top plate has front and rear. Install with edge in rear (away from user). User can remove entire chassis to change configuration or adjust power.
If mounting permanently, install 2 hex head screws using top plate as a template for the
2 screw locations.
• Do not install chassis with front against a surface that can block access or prevent assembly.
• Always release the front latch to remove the chassis or top plate.
• View front labels to ensure unit will achieve correct orientation. An easy visual cue is with the Sounder on the left.
Page 5 of 7
Checkpoint Systems, Inc.
– Field Service Installation Document – CKP P/N 10073883
Wiring Procedure
connector, then route cable(s) through the clips for strain relief. Dog-bone excess antenna cable with provided tie wrap.
Figure 2: Antenna Wiring, Primary Connection (Cable Routing on right)
2. If there are peripherals such as a Key Switch or an external scanner Interlock to connect, use the following table for the wiring pin-out:
4
5
6
2
3
Pin # Interlock/Alarm (J6)
1 INTLK+
GND
INTLK (OPTO)
INTLK (OPTO)
ALARM+
ALARM-
GPIO/12V (J5)
GPO RLY
GPO RLY
GPI+
GND
+12V
GND
3. Connect AC cord to PSU. Connect PSU to chassis rear
DC Input and slide jack behind the strain relief as shown in Figure 4 below. Route cabling to avoid snags. If necessary, use tie wrap to bundle excess.
Figure 3: PSU and Regional AC Cord
Page 6 of 7
Quick Start Guide: Counterpoint iD
Figure 4: PSU DC Cord Strain Relief
4. Configure the DIP Switches on the front panel for the desired operation.
Note: For details on “Mode Configurations”, see
DIP Switch Functions on page 3 above.
5. System is ready to power ON. With no advanced features required, the final step is to press Reset button, wait for the Violet LED, then press reset again to tune.
6. Optional: Connect field service laptop to front RS-232 port via patch cable, then perform any FW upgrades or advanced tuning with DMS. See Help File for more.
Tuning
CPiD needs to be tuned upon installation or it will not function.
Using DMS SW features (see below), advanced antenna tuning may help achieve desired detection, but keep in mind:
• Avoid interactions when located near EAS pedestal/antennas.
• Tune system for immunity/ False Alarms for the detector.
See Also
DMS version 1.8.95 and later will feature a help file to cover all SW-based configurations and settings for using CPiD. To access the instructions, click
Help (or press F1) > Help Files > Counterpoint ID.
Page 7 of 7
Appendix A: Regulatory and Safety
Important Information to our Users in North America
FCC Regulatory Compliance Statement
Checkpoint Systems, Inc., offers Electronic Article Surveillance (EAS) or Radio Frequency
Identification Products that have been FCC certified or verified to 47 CFR Part 15 Subparts B/C.
Appropriately, one of the following labels will apply to the approval:
NOTE: This equipment has been tested and found compliant within the limits for a class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
This equipment generates, uses, and can radiate interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at own expense.
- OR -
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) including this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation, which may include intermittent decreases in detection and/or intermittent increases in alarm activity.
Industry Canada Regulatory Compliance Statement
This device complies with the Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions:
1.
This device may not cause interference, and
2.
This device must accept any interference, including interference that may cause undesired operation of the device.
Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication.
This radio transmitter (IC: 3356B-CPID) has been approved by Industry Canada to operate with the antenna types listed below with the maximum permissible gain and required antenna impedance for each antenna type indicated. Antenna types not included in this list, having a gain greater than the maximum gain indicated for that type, are strictly prohibited for use with this device.
Antenna Type
Counterpoint pad
Royston antenna
NCR 7876
NCR 7878
Antenna Structure
1 turn loop
1 turn loop
2 turn loop
1 turn loop
Antenna Size
12” x 12”
13” x 6”
8.5” x 6.5”
6” x 6”
Page A-1
Antenna Type Antenna Structure
Conveyor
Deactivation Pad
1 turn loop
Handheld deactivator 1 turn loop
Hand scan antenna 1 turn loop
Sheet deactivator
Magellan 8400/9800
Metrologic MS2420
Motorola MP6000
1 turn loop
1 turn loop
1 turn loop
1 turn loop
Antenna Size
9.8” x 9.8”
10” x 8”
6.8” x 1.5”
9.4” x 9.4”
8” x 8”
8” x 8”
8” x 8”
Equipment Compliance Statement
Checkpoint’s Electronic Article Surveillance (EAS) products have been designed for safeness during normal use and, where applicable have been certified, listed, or recognized in accordance with one or more of the following safety standards; UL 60950-1, CSA C22.2 No. 60950-1-07. Additional approvals may be pending.
WARNING: Changes or modifications to Checkpoint’s EAS or Radio Frequency Identification (RFID) equipment not expressly approved by the party responsible for assuring compliance could void the user’s authority to operate the equipment in a safe or otherwise regulatory compliant manner.
Page A-2
Appendix A: Regulatory and Safety
Important Information to our Users in Europe
CE Regulatory Compliance Statement
Where applicable, Checkpoint Systems, Inc. offers certain Electronic Article Surveillance (EAS) products that have CE Declarations of Conformity according to R&TTE Directive 99/5/EC, EMC
Directive 2004/108/EC, and Low Voltage Directive 2006/95/EC.
System Electromagnetic Compatibility (EMC) has been tested and notified through Spectrum
Management Authorities if necessary, using accredited laboratories, whereby, conformity is declared by voluntarily accepted European Telecommunications Standards Institute (ETSI) standards EN
301489-3 and EN 302208 and/or EN 300330, as applicable.
NOTE: Certain Electronic Article Surveillance (EAS) equipment have been tested and found to conform to the CE emission and immunity requirement in Europe. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Under unusual circumstances, interference from external sources may degrade the system performance, which may include intermittent decreases in detection and/or intermittent increases in alarm activity. However, there is no guarantee that interference will not occur in a particular installation. If this equipment experiences frequent interference from external sources or does cause harmful interference to radio communications reception, which can be determined by turning the equipment off and on, please contact a Checkpoint Systems representative for further assistance.
RoHS Compliance Statement
The RoHS Directive stands for "the restriction of the use of certain hazardous substances in electrical and electronic equipment." A RoHS compliant product means that electrical and electronic equipment cannot contain more than maximum permitted levels of lead, cadmium, mercury, hexavalent chromium, polybrominated biphenyl (PBB) and polybrominated diphenyl ether (PBDE). Checkpoint is in compliance with the RoHS directive.
WEEE Compliance Statement
The Waste Electrical and Electronic Equipment Directive (WEEE) applies to companies that manufacture, sell, distribute, or treat electrical and electronic equipment in the European Union. There are a number of obligations imposed on Checkpoint as a supplier of electrical and electronic equipment. Checkpoint's compliance approach for each of these obligations is provided below.
Page A-3
WEEE Marking
All products that are subject to the WEEE Directive supplied by Checkpoint are compliant with the WEEE marking requirements. Such products are marked with the "crossed out wheelie bin" WEEE symbol shown below in accordance with European Standard EN 50419.
Information for Users
According to the requirements of European Union member state WEEE legislation, the following user information is provided in English for all Checkpoint supplied products subject to the WEEE directive.
This symbol on the product or on its packaging indicates that the product must not be disposed of with normal waste. Instead, it is your responsibility to dispose of your waste equipment by arranging to return it to a designated collection point for the recycling of waste electrical and electronic equipment. By separating and recycling your waste equipment at the time of disposal you will help to conserve natural resources and ensure that the equipment is recycled in a manner that protects human health and the environment. For information about how to recycle your Checkpoint supplied waste equipment, please contact the Checkpoint
Systems, Inc. Field Service office in your region. Customers can obtain this information from their system User’s Guide.
REACH Compliance Statement
The European REACH Regulation 1907/2006 on Registration, Evaluation, Authorization, and Restriction of
Chemicals (REACH), Annex XVII entered into force in June 2009, and affects all companies producing, importing, using, or placing products on the European market. The aim of the REACH regulation is to ensure a high level of protection of human health and the environment from chemical substances.
Checkpoint Systems’ substances management system follows and complies with the current revision of the
REACH Regulation on the substances as identified by ECHA (European Chemical Agency).
Checkpoint Systems’ products are considered articles as defined in REACH Article 3 (3).
These products/articles under normal and reasonable conditions of use do not have intended release of substances. Therefore the requirement in REACH Article 7 (1) (b) for registration of substances contained in these products/articles does not apply.
Checkpoint Systems’ products/articles do not contain Substances of Very High Concern or if there are
SVHC in the product/article, the content is less than the 0.1% (wt/wt) as defined by REACH Article 57,
Annex XIV, Directive 67/548/EEC. Therefore the requirement in REACH Article 7 (2) to notify ECHA if a product/article contains more than 0.1% wt/wt of an SVHC and tonnage exceeding 1 tonne per importer per year is not applicable.
Checkpoint Systems’ European operations do not manufacture or import chemicals, therefore Checkpoint
Systems has no obligation to register substances.
Packaging Compliance Statement
No CFCs (chlorofluorocarbons), HCFCs (hydrofluorocarbons) or other ozone depleting sub-stances are used in packaging material. Chromium, lead, mercury, or cadmium are not intentionally added to packaging materials and are not present in a cumulative concentration greater than 100 ppm as incidental impurities.
No halogenated plastics or polymers are used for packaging material. Checkpoint complies with the EU
Directive 94/62/EEC.
Page A-4
Télécharger
Publicité