ELAN TP7 touch panel Quick Install Guide
Elan TP7 is a 7-inch touch panel user interface designed for use in low-humidity indoor environments. It can be mounted in either portrait or landscape orientation and includes a mounting bracket for easy installation. The TP7 has a built-in microphone, speaker, and camera, and it supports both wired Ethernet and 802.11 B/G/N WiFi connectivity. It also has a USB Type A port and a 1/8" stereo audio output. The TP7 can be powered by either a 12v DC power supply or via Power over Ethernet (PoE).
The TP7 is a versatile device that can be used for a variety of purposes, including:
- Controlling home automation systems
Reklam
Reklam
Job: Universal Manual
Size: 150 x 150 mm folded
07/30/2014 -> Final print pdf
ELAN & Niles & SpeakerCraft
Quick Install Guide –
TP7
8 pages each
- Format: 150 x 300 mm ( Metric !! )
Final Print pdf /
Rev B
English only
07/30/2014 - WE
Questions?
Juergen 707 - 778 - 5826
P/N 9901341 REV. B 07/2014
Folding-Method:
150 150 150
English
TP7 – 7” Touch Panel
User Interface
Quick Install Guide
150
+
Folded size:
150 x 150 mm
Open:
600 mm wide x 300 mm high
No bleed
English
TP7 – 7” Touch Panel
User Interface
Quick Install Guide
9901341_Rev-B_Universal_TP7_QSG_0730_PRINT.indd 1-4 7/30/14 9:59 AM
2 Powering up the TP7
Once installation is complete, press the Power button located on top of the TP7 and allow the unit to boot up.
- If connected to a wired Ethernet switch the TP7 will aquire a network address
via DHCP and automatically connect to the system.
- If the TP7 does not detect a wired Ethernet connection and the WiFi radio has never been confi gured
you will be presented with the Network Confi guration Utility interface. To complete the network
confi guration please refer to the most current training documentation for your system.
4 Setting screen orientation
The TP7 is shipped pre-confi gured for landscape orientation.
To change orientation:
– Tap the POWER button 10 times in quick succession
– Follow the on-screen instructions to re-orient the screen
Power
3 Removing the TP7
– Using two hands grasp it on each side or the top and bottom and pull straight
out from the wall. It will require approx. 10lbs of force to remove it from the bracket.
Mounting Bracket Mounting Bracket
Top of 2 Gang Box
Dry Wall
TP7 Frame
5 RESET
The recessed RESET button has two functions
– A tap of the button will reset all network confi guration
– Press and hold the button for 15 seconds completely restores
the factory default settings.
CAUTION:
Neither of these actions can be reversed.
Recessed
Reset Switch
Recessed
Reset Switch
LAN + Power over Ethernet
Paper Clip
9901341_Rev-B_Universal_TP7_QSG_0730_PRINT.indd 5-8
Important Safety Instructions
1. Read, understand and follow ALL safety and installation instructions included in this manual.
Failure to follow the included documentation may damage the product and will void manufacturer’s warranty.
2. Follow ALL installation guidelines included with the product. Installation of the product in high humidity environments,
in close proximity to heat sources and /or non-recommended locations WILL impede, interfere and/or damage
the intended operation of the product
3. Only use attachments and accessories which have been specifi ed for use by the manufacturer.
4. The use of abrasive, liquid or solvent based cleaning fl uids WILL damage the product.
Please refer and follow all Product Care instructions included with the product.
5. Product Servicing may ONLY be completed by authorized or certifi ed service centers & personnel.
For a complete list of product servicing options, please follow instructions included in the product
documentation and /or contact original manufacturer for details.
FEDERAL COMMUNICATIONS COMMISSION INTERFERENCE STATEMENT:
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/ TV technician for help.
FCC and IC Information:
This Class B digital apparatus complies with Part 15 of the FCC rules and with Canadian ICES-003 and RSS-210.
Operation is subject to the following two conditions:
1. This device may not cause interference and
2. This device must accept any interference, including interference that may cause undesired operation of the device.
Cet appareil numérique de classe B est conforme aux normes canadiennes ICES-003 et RSS-210. Son fonctionnement est soumis aux deux conditions suivantes : (1) cet appareil ne doit pas causer d’interférence et (2) cet appareil doit accepter toute interférence, notamment les interférences qui peuvent affecter son fonctionnement.
Warning: Changes or modifi cations to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
FCC and IC Radiation Exposure Statement:
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment and meets the exemption from the routine evaluation limits in section 2.5 of RSS 102.
1. This Transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
2. This equipment complies with FCC RF radiation exposure limits set forth for an uncontrolled environment.
This equipment should be installed and operated with a minimum distance of 20 centimeters from user and bystanders.
Informations concernant l’exposition aux fréquences radio (RF):
La puissance de sortie émise par l’appareil de sans fi l est inférieure à la limite `exposition aux fréquences radio d’Industry
Canada (IC). Utilisez l’appareil de sans fi l de façon à minimiser les contacts humains lors du fonctionnement normal.
Ce périphérique a également été évalué et démontré conforme aux limites d’exposition aux RF d’IC dans des conditions d’exposition à des appareils mobiles (antennes sont supérieures à 20 cm à partir du corps d’une personne).
Warning: The device meets the exemption from the routine evaluation limits in section 2.5 of RSS 102, and users can obtain Canadian information on RF exposure and compliance from the Canadian Representative
Product Solutions Group at Tel: (519) 763-4538.
TP7
– 7” Touch Panel
User Interface
Quick Install Guide
English
Thank you for including the TP7 as part of the user interface strategy for your customer. The TP7 has been designed to provide years of trouble free operation when wired and installed properly. The TP7 has been designed for installation in low humidity indoor environments and should never be installed outdoors or in high humidity areas.
Included in the box
•
1ea TP7 touch panel
• 1ea TP7 mounting bracket
•
4ea Mounting screws
• 1ea DC power connector
Introduction
To install the TP7 you will also need a standard 2 gang
US junction box or low voltage bracket.
Specifi cations
Dimensions Overall 8”w x 5”h
Mounting Depth 1 ¾”
Microphone Dual Digital Beam Forming
Far Field Pickup
Speaker
Camera
Display
Network
2w integrated
640 x 480
7”
800 x 480
10/100 Ethernet
Connections
LAN/PoE
Power
USB
Audio Out
RJ-45
2 pin Phoenix
USB Type A
1/8” stereo (Future Use)
Power Requirements
Direct – 12v DC 350mA
PoE – IEEE 802.3at,
13w maximum draw
(@44 V /350 mA max)
© 2014 Core Brands, LLC. All rights reserved.
Core Brands, LLC, a Nortek company.
P/N 9901341 Rev. B 07/2014
7/30/14 9:59 AM
TP7 – Overview
Power
Status LED
Speaker
Camera
Microphone
Proximity Sensor
DC Power
Input
LAN + Power over Ethernet
USB
Recessed
Reset Switch
Audio Out
(Future Use)
Recessed
Reset Switch
Planning the installation
The TP7 is designed to wall mount in either Portrait or Landscape orientation.
Ensure there is adequate wall space for the TP7 and that the surface is relatively smooth.
The TP7 requires a minimum mounting depth of 1 ¾” (4.5 cm) from the front surface plus room for wire. Ensure that adequate depth is available.
Power may be supplied by Power Over Ethernet (PoE) or by a 12v DC power supply (not included).
PoE must meet the IEEE 802.3af standard. Direct power via a 12v DC external power supply requires a minimum current output of 350mA.
The TP7 connects to the local network via Ethernet or Wi-Fi. When utilizing Wi-Fi you must ensure that there is adequate Wi-Fi coverage at the mounting location.
1
Installing the TP7
a. Mounting height
– Depending on how tall your homeowner is, it is recommended to locate the center
of TP 7 between 57”- 65” (145 cm -165 cm) above the finished floor.
165 cm / 65”
145 cm / 57”
9901341_Rev-B_Universal_TP7_QSG_0730_PRINT.indd 9-12 b. Rough-In
The TP7 has been designed to mount to a US standard 2 gang box or low voltage bracket.
- The TP7 is “snap” fit into the box/bracket and requires approximately 10lbs of force
to remove it from the wall. Ensure that the mounting method you are using is compatible
with these requirements.
New Const. Box Old Work Box e. Installing the TP7 Bracket
– The TP7 includes a mounting bracket that MUST be used. Using the included screws mount
the bracket onto the 2 gang box or low voltage bracket and verify that the bracket is level
before tightening the screws.
– The mounting bracket is designed to level out uneven wall surfaces allowing the TP7 to fit
securely on most any surface. Note that uneven surfaces will create a gap between the back
of the panel and the wall – this is normal. Do not tighten the mounting bracket so as to
distort it’s shape as this will create issues with properly seating the TP7 in the bracket.
12v Power Supply
– By utilizing a 12v power supply (not included) to power the TP7 you may provide power
locally or remotely. If powering locally be sure to run the wire through the wall
in accordance with local codes. If powering remotely be sure to use wire of adequate
gauge for the length of the run.
– Verify the polarity of your power supply prior to termination and ensure the power
supply is not connected to a power source.
– Strip approx. ¼” of insulation from the wire and observing the correct polarity, terminate
the wire into the supplied connector and tighten firmly. Be sure to twist the wires before
inserting so that no strands escape the connector. Inspect the termination to verify that
the wire is securely retained by the connector and no strands have escaped the barrier.
– Plug the connector into the TP7.
F-2
Front of
Mounting Bracket
Back of TP7
TP7 Touch Panel
Phoenix Type
Connector
Line in wall
New Const. Low Volt Bracket Old Work Low Volt Bracket c. Landscape Mounting
– Install the 2 gang box or bracket in it’s normal orientation – with mounting screw holes
at the top and bottom. The box is exactly centered with the touch panel for your convenience.
Power
2 Gang Box
TP7 d. Portrait Mounting
– Install the 2 gang box or bracket rotated 90° - with the mounting screw holes on the left
and right sides. The box is exactly centered in the touch panel for your convenience.
2 Gang Box
Power
TP7
F-1-A f. Connecting the TP7 to power
– The TP7 is designed to be powered over the Ethernet connection (PoE) or by connecting
a 12v power supply (not included), but not both. If both the PoE and a 12v power supply
are connected the TP7 will draw power from the 12v source.
PoE Connection
– PoE connection requires that IEEE 802.3af standard (13w maximum draw @44 VDC/350mA max)
is met. Utilize a network switch or PoE injector that meets this standard.
– Connect the TP7 using a standard T568A or T568B Ethernet cable from the network switch
to the LAN/PoE jack. If you have terminated your own CAT 5e/6/7 cable use a tester
to ensure that both ends have been properly terminated.
To TP7
PoE Injector
F-1-B
Network Switch
TP7 Touch Panel
PoE Network Switch g. Connecting Ethernet
– When not utilizing PoE, but you have a physical network connection available it
is recommended that you connect the TP7 directly to the network switch.
– Utilizing a T568A or T568B network cable connect to the LAN/PoE jack.
If you have terminated your own CAT 5e/6/7 cable use a tester to ensure that both
ends have been properly terminated.
h. Mounting the TP7
– The TP7 is held into the mounting bracket by spring steel tabs.
– Orient the TP7 with the POWER button at the top right for landscape mounting
or the top left for portrait mounting.
– To complete the installation simply grasp the TP7 on the edges and press firmly on to
the bracket until it is seatled.
CAUTION:
DO NOT PRESS DIRECTLY ON THE SCREEN when installing on to the mounting bracket. Press only on the frame edges.
Mounting Bracket Mounting Bracket
Top of 2 Gang Box
Dry Wall
TP7 Frame
7/30/14 9:59 AM
İndir
Reklam