advertisement
B
4
RADIATOR/EXHAUST
DISCHARGE AIR
(BOTH SIDES)
443
[17.5]
187
[7.4]
EXHAUST MUFFLER
ENCLOSED WITHIN
GENERATOR ENCLOSURE
REMOVE COVER
FOR ACCESS TO
RADIATOR FILL CAP
AIR INTAKE
(BOTH SIDES)
BATTERY 12V
GROUP 26
NEGATIVE GROUND
P/N: 077483
TOP VIEW
749.3 [29.5]
CENTER OF GRAVITY
(SEE NOTE 5)
3
SERVICE ITEM
OIL FILL CAP
OIL DIP STICK
OIL FILTER
2.4L
EITHER SIDE
RIGHT SIDE
RIGHT SIDE
OIL DRAIN HOSE
RADIATOR DRAIN HOSE
RIGHT SIDE
LEFT SIDE
COOLANT RECOVERY BOTTLE LEFT SIDE
RADIATOR FILL CAP ROOF TOP
AIR CLEANER ELEMENT
SPARK PLUGS
MUFFLER
DRIVE BELT
FAN BELT
BATTERY
LUBE OIL MAINTAINER
SUPPLY TANK FILL CAP
LEFT SIDE
LEFT SIDE
SEE NOTE 11
EITHER SIDE
SEE NOTE 11
LEFT SIDE
ROOF TOP
REFERENCE OWNERS MANUAL
FOR PERIODIC REPLACEMENT
PART LISTINGS.
SH
REMOVE COVER FOR
ACCESS TO LUBE OIL
MAINTAINER SUPPLY TANK
REFERENCE OWNERS MANUAL
CIRCUIT BREAKER
SEE NOTE 3
1/2
REV
D
WINDCHILL VERSION
D.1
1
NOTES:
1. MINIMUM RECOMMENDED CONCRETE PAD SIZE IS 6" OFFSET OF OVERALL LENGTH
AND WIDTH OF GENERATOR. {1193.8 (47") WIDE X 2255.5 (88.8") LONG}. REFERENCE
INSTALLATION GUIDE SUPPLIED WITH THE UNIT FOR CONCRETE PAD GUIDELINES.
REFERENCE MANUFACTURER'S SPECIFICATIONS IF USING ENGINEERED, PREFABRICATED SLABS.
2. ALLOW SUFFICIENT ROOM ON ALL SIDES OF THE GENERATOR FOR MAINTENANCE
AND SERVICING. THIS UNIT MUST BE INSTALLED IN ACCORDANCE WITH CURRENT
APPLICABLE NFPA 37 AND NFPA 70 STANDARDS AS WELL AS ANY OTHER FEDERAL,
STATE, AND LOCAL CODES.
3. CONTROL PANEL / CIRCUIT BREAKER INFORMATION:
- SEE SPECIFICATION SHEET OR OWNERS MANUAL
- ACCESSIBLE THROUGH CUSTOMER ACCESS ASSEMBLY DOOR ON REAR OF GENERATOR.
4. REMOVE THE REAR ENCLOSURE COVER PANEL TO ACCESS
THE STUB-UP AREAS AS FOLLOWS:
- HIGH VOLTAGE CONNECTION INCLUDING AC LOAD LEAD CONDUIT CONNECTION
NEUTRAL CONNECTION, BATTERY CHARGER 120 VOLT AC (0.5 AMP MAX) CONNECTION.
- LOW VOLTAGE CONNECTION INCLUDING TRANSFER SWITCH CONTROL WIRES.
5. CENTER OF GRAVITY AND WEIGHT MAY CHANGE DUE TO UNIT OPTIONS.
6. BOTTOM OF GENERATOR SET MUST BE ENCLOSED TO PREVENT PEST INTRUSION AND
RECIRCULATION OF DISCHARGE AIR AND/OR IMPROPER COOLING AIR FLOW.
7. REFERENCE OWNERS MANUAL FOR LIFTING WARNINGS.
8. MOUNTING BOLTS OR STUDS TO MOUNTING SURFACE SHALL BE 5/8-11 GRADE 5
(USE STANDARD SAE TORQUE SPECS)
9. MUST ALLOW FREE FLOW OF INTAKE AIR, DISCHARGE AIR AND EXHAUST. SEE SPEC
SHEET FOR MINIMUM AIR FLOW AND MAXIMUM RESTRICTION REQUIREMENTS.
10. GENERATOR MUST BE INSTALLED SUCH THAT FRESH COOLING AIR IS AVAILABLE
AND THAT DISCHARGE AIR FROM RADIATOR IS NOT RECIRCULATED.
11. EXHAUST MUFFLER AND FAN BELT ENCLOSED WITHIN GENERATOR ENCLOSURE,
REMOVE FRONT PANEL TO ACCESS.
759 [29.9]
DOOR TYP
VICE ACTION LATCH,
ONE PER DOOR,
ONE LIFT OFF
DOOR PER SIDE
OF GENERATOR
B
A
RADIATOR/EXHAUST
DISCHARGE AIR
DRAWING CREATED FROM PRO/ENGINEER
3D FILE. ECO MODIFICATION TO BE
APPLIED TO SOLID MODEL ONLY.
4
REAR ENCLOSURE
COVER PANEL
SEE NOTE 4
1171
[46.1]
OVERALL
HEIGHT
50
[2.0]
LEFT SIDE VIEW
1000 [39.4]
FUEL LINE CONNECTION
3/4" NPT FEMALE COUPLING
888 [35.0]
OVERALL WIDTH
REAR VIEW
ENGINE/KW
2.4L 36KW
2.4L 36KW
2.4L 45KW
2.4L 45KW
ENCLOSURE
MATERIAL
ST
AL
ST
AL
WEIGHT DATA
WEIGHT
GENSET ONLY
KG [LBS]
WEIGHT
SHIPPING SKID
KG [LBS]
569 [1255]
545 [1202]
596 [1313]
572 [1260]
44 [98]
44 [98]
44 [98]
44 [98]
3
58
[2.3]
TYP
CUSTOMER ACCESS
ASSEMBLY, CONTROL
PANEL ACCESS,
BATTERY CHARGER
LOCATED WITHIN
SEE NOTE 4
47
[1.8]
1857 [73.1] TYP
1950 [76.8]
OVERALL LENGTH
RIGHT SIDE VIEW
SHIPPING WEIGHT
KG [LBS]
613 [1353]
590 [1300]
640 [1411]
616 [1358]
DIMENSIONS: MM [INCH]
GENERAC POWER SYSTEMS OWNS THE COPYRIGHT OF THIS DRAWING
WHICH IS SUPPLIED IN CONFIDENCE AND MUST NOT BE USED FOR
ANY PURPOSE OTHER THAN FOR WHICH IT IS SUPPLIED WITHOUT
THE EXPRESS WRITTEN CONSENT OF GENERAC POWER SYSTEMS.
c GENERAC POWER SYSTEMS 2013
2
ELECTRONICALLY APPROVED
INSIDE WINDCHILL
TITLE
INSTALL CPL PROT G2.4L C2
36/45KW
ISSUE DATE:
SIZE
B
SCALE
CAGE NO DWG NO
N/A
0.050 WT-KG
0K8636
SEE ABOVE SHEET
1
REV
D
1 of 2
A
B
4
50 [2.0]
TYP
A
DRAWING CREATED FROM PRO/ENGINEER
3D FILE. ECO MODIFICATION TO BE
APPLIED TO SOLID MODEL ONLY.
4
13.5 X 29.5
MOUNTING SLOTS
4X
TOP VIEW
1708
[67.2]
3
1750 [68.9] TYP
MOUNTING SLOT CENTERS
1950 [76.8]
LEFT SIDE VIEW
3
SH
2/2
REV
D
WINDCHILL VERSION
D.1
1
* NOTE: STUB-UP AREA FOR HIGH AND LOW
VOLTAGE CONNECTIONS, CIRCUIT BREAKER,
NEUTRAL AND CUSTOMER CONNECTION OPENING.
37
[1.5]
B
HIGH AND LOW
VOLTAGE
STUB-UP AREA
162
[6.4]
* STUB-UP
AREA
786
[30.9]
233
[9.2]
9
[.4]
162 [6.4]
* STUB-UP
AREA
51
[2.0]
REMOVABLE
STUB-UP COVER
850 [33.5]
116 [4.6]
25 [1.0]
TYP
838 [33.0] TYP
MOUNTING SLOT CENTERS
888 [35.0]
REAR VIEW
TITLE
DIMENSIONS: MM [INCH]
GENERAC POWER SYSTEMS OWNS THE COPYRIGHT OF THIS DRAWING
WHICH IS SUPPLIED IN CONFIDENCE AND MUST NOT BE USED FOR
ANY PURPOSE OTHER THAN FOR WHICH IT IS SUPPLIED WITHOUT
THE EXPRESS WRITTEN CONSENT OF GENERAC POWER SYSTEMS.
c GENERAC POWER SYSTEMS 2013
2
ELECTRONICALLY APPROVED
INSIDE WINDCHILL
INSTALL CPL PROT G2.4L C2
36/45KW
ISSUE DATE:
SIZE
B
SCALE
CAGE NO
N/A
DWG NO
0K8636
0.100 WT-KG SEE SHEET 1 SHEET
1
REV
2 of 2
D
A