Truma Boiler Elektro BE14 Operating Instructions Manual
Truma Boiler Elektro BE14 - Below you will find brief product information for Truma Boiler Elektro BE14. This device is an electric boiler that can heat up to 14 liters of water using an electric heating element (230 V, 850 W), providing hot water for various purposes such as showers, sinks and other appliances that require hot water. The boiler's temperature is limited to approximately 70 degrees Celsius for safety reasons, and it features overtemperature protection to prevent overheating.
Advertisement
Advertisement
Boiler Elektro
Operating instructions
To be kept in the vehicle!
Page 2
Boiler Elektro (Electric Boiler)
Table of Contents
Symbols used ........................................................................ 2
Model .................................................................................... 2
Intended use .......................................................................... 2
Operating instructions
Operating instructions
Important operating notes ................................................ 2
Filling the boiler .................................................................. 3
Draining the boiler ............................................................. 3
Start-up ................................................................................ 4
Maintenance ....................................................................... 4
Disposal ................................................................................. 4
Technical data ..................................................................... 5
Declaration of conformity ................................................. 5
Truma Manufacturer’s Warranty ..................................... 5
Important operating notes
This device can be used by children aged 8 and over, as well as by persons with reduced
physical, sensory or mental capabilities or with a lack of experience and knowledge, provided that they are supervised or have been
instructed on how to use the unit safely and that they understand the resulting risks. Children must not be allowed to play with the unit.
Repairs may only be carried out by an expert.
Symbols used
Symbol indicates a possible hazard.
Note containing information and tips.
Model
Boiler Elektro (electric boiler) (BE 14)
Intended use
The Boiler Elektro (electric hot water generator) heats up water using an electric heating element (230 V, 850 W).
Guarantee claims, warranty claims and acceptance of liability will be ruled out in the event of the following:
– Modifications to the device (including accessories),
– Using replacement and accessory parts
other than original Truma parts,
– Failure to follow the installation and operating instructions.
The device’s operating permit, and consequently also the vehicle’s operating permit in some countries, are also rendered void.
If only the cold water system is being operated without the boiler, the boiler also fills up with water. To avoid frost damage, the water in the boiler must be drained by operating the safety/drain valve, even if the boiler has not been used. Alternatively, two hot water-resistant shut-off valves can be fitted upstream of the cold and hot water connection.
If the boiler is connected to a central water supply (rural or urban connection), a pressure reducer must be used, which will prevent pressures higher than 2.8 bar from occurring.
In Germany, the Truma Service Centre must
always be notified in the event of faults; in
other countries the respective service partners are available (see www.truma.com).
2
The installer or vehicle owner must affix the yellow sticker with the warning information, which is enclosed with the appliance, in a location in the vehicle where it is clearly visible to all users (e.g. the wardrobe door)! Missing stickers can be requested from Truma.
Always observe the operating instructions and the “Important operating notes” prior to starting!
The vehicle owner is responsible for correct operation of the appliance.
Filling the boiler
Check that the safety/drain valve in the cold water supply is closed: Lever horizontal, position (a).
The safety/drain valve must be actuated regularly in order to prevent limescale deposits and to ensure that it is not blocked.
a b a
Before initial use, be sure to flush the entire water supply thoroughly with water.
The boiler should be drained when it is not being used in order to avoid the risk of frost! No claims may be made under the warranty for damage caused by frost!
The materials of the device that come into contact with water are drinking water safe
(see manufacturer’s declaration www.truma.com – Downloads –
Manufacturer’s declaration).
Figure 1 a = Lever position “Closed” b = Lever position “Drain”
Turn on the hot water tap in the bathroom or the kitchen.
In the case of thermostatic or single-lever mixer taps, set to
“warm”.
Switch on power to pump assembly (main switch or pump switch).
Leave the fittings open for as long as it takes for the boiler to displace the air and fill up and for water to flow.
In the event of frost, filling may be prevented by frozen residual water. The boiler can be thawed by turning it on briefly (no more than 2 minutes). Frozen lines can be thawed by heating the interior.
Draining the boiler
If the caravan is not being used during the frost period, the boiler must be drained!
Disconnect power to pump assembly (main switch or pump switch).
Turn on the hot water taps in the bathroom and kitchen.
Open safety/drain valve: Lever vertical, position (b).
The boiler will now be drained directly to the outside via the safety/drain valve. Check that all the water has drained out of the boiler (14 litres).
3
Troubleshooting guide
Fault Cause
Water not getting hot.
– No operating voltage.
– Operation without water; overtemperature protection switching heating element off.
– Water container furred.
Water taking an extremely long time to heat up.
Water running away – boiler cannot be filled
– Safety/drain valve is open.
Boiler cannot be drained, even though the safety/drain valve is open.
– Drainage socket of safety/ drain valve closed.
– Venting hose closed off.
Water dripping out of drainage socket of safety/drain valve.
– Elbow fitting twisted at boiler.
– Water pressure too high.
Remedy
– Restore power supply.
– Switch off, wait for 10 minutes, fill with water, switch on.
– Descale water system (see maintenance).
– Close safety/drain valve.
– Check opening for soiling (slush, ice, leaves etc.) and remove if necessary.
– Check opening (see above).
– Check hose for kinks and correct.
– The aeration valve on the elbow fitting must face to the side.
– Check pump pressure (max. 2.8 bar). If the boiler is connected to a central water supply (rural or urban connection), a pressure reducer must be used, which will prevent pressures higher than 2.8 bar from occurring.
If these actions do not remedy the problem, please contact Truma Service.
Start-up
The boiler must not be operated with a time switch.
Boiler EL d c
Figure 2 c = Toggle switch “On” d = Toggle switch “Off”
230 V ~
Switch on boiler at control panel (c). The indicator light indicates that the device is operating.
Use of vehicle-specific switches: see operating instructions from vehicle manufacturer.
The water temperature cannot be preselected, auto- matic temperature limit at approx. 70 °C.
The electric heating element is equipped with overtemperature protection. If the device is operated without
water, the overtemperature protection switches it off at 90 °C.
In order to switch it on again, the device must cool to less than 24 °C and be switched “Off” and “On” again (Reset).
Maintenance
Only original Truma parts may be used for maintenance and repair work.
We recommend the use of suitable commercially available products to clean, sterilise and maintain the boiler. Products containing chlorine are not suitable.
The boiler should be heated to 70 °C at regular intervals to prevent infestation by microorganisms.
Disposal
The device must be disposed of in accordance with the administrative regulations of the respective country in which it is used. National regulations and laws (in Germany, for example, the End-of-life Vehicle Regulation) must be observed.
In other countries, the relevant regulations must be observed.
4
Technical data
Determined in accordance with Truma test conditions
Power supply
230 V ~, 50 Hz
Power consumption
3.7 A (850 W)
Water capacity
14 litres
Heating time from approx. 15 °C to approx. 70 °C approx. 70 min.
Temperature limit
70 °C
Overtemperature protection
90 °C
Pump pressure max. 2.8 bar
System pressure max. 4.5 bar
Weight (empty) approx. 3 kg
Dimensions
Height: 295 mm
Width: 405 mm
Subject to technical changes.
Declaration of conformity
1. Information about the manufacturer
Name:
Address:
Truma Gerätetechnik GmbH & Co. KG
Wernher-von-Braun-Str. 12, D-85640 Putzbrunn
2. Device identification
Type / model:
BE 14 Boiler Elektro (electric boiler)
3. Meets the requirements of the following directives
3.1 Low Voltage Directive 2014/35/EU
3.2 End-of-Life Vehicle Directive 2000/53/EC
3.3 Drinking Water Directive 98/83/EC and bears the CE mark.
4. Basis of the proof of conformity
IEC 60335-2-21:2002 (Fifth Edition) (incl. Corr. 1:2007) +
A1:2004 + A2:2008 used in conjunction with IEC 60335-
1:2010 (Fifth edition); DIN 2001-2 ; DVGW W270, KTW.
5. Monitoring body
Federal Motor Transport Authority (Kraftfahrt-Bundesamt)
6. Signatory details
Signature: Frank Oster
Managing Director Putzbrunn, 10.12.2014
Truma Manufacturer’s Warranty
1. Warranty claims
The Manufacturer hereby warrants for all defects of the unit caused by material or production faults. In addition, the seller continues to be subject to any statutory warranty claims.
No warranty claim shall be applicable under the following circumstances:
– Consumable parts which are subject to wear and tear
– Use of parts other than original Truma components in any of the units
– In gas pressure regulation systems: damage caused by
foreign substances in the gas (e.g. oils, plasticisers)
– Failure to observe Truma’s installation or operating instructions
– Improper handling
– Improper transport packing
2. Scope of warranty
The warranty covers all defects under clause 1 that occur within 24 months upon concluding the purchase agreement between the seller and the end customer. The Manufacturer undertakes to remedy such defects through subsequent fulfilment, i.e. at its discretion either by repairing or replacing the defective item. If the Manufacturer remedies a defect under its warranty commitment, the term of the Warranty shall not recommence anew with regard to the repaired or replaced parts; rather, the original warranty period shall continue to be applicable. No further-reaching claims shall be permitted, especially damage claims presented by purchasers or third parties. This provision shall not affect the validity of the German
Product Liability Act (Produkthaftungsgesetz).
The Manufacturer shall bear the cost of employing the Truma
Customer Service for the removal of warranty defects – in particular, transportation, travelling, job and material costs – provided that the Customer Service conducts its work within
Germany. This Warranty does not cover Customer Service work outside Germany.
Additional costs arising from complicated removal or instal- lation jobs on the unit (e.g. dismantling of furnishings or parts of the vehicle body) are not covered by the Warranty.
3. Making a claim under the warranty
The Manufacturer’s address is:
Truma Gerätetechnik GmbH & Co. KG
Wernher-von-Braun-Straße 12
85640 Putzbrunn, Germany
Should problems occur, please contact the Truma Service
Centre or one of our authorised service partners (see www.
truma.com). Please describe your claim in detail and state the serial number of the unit and the date of purchase.
To help the Manufacturer determine whether your claim is covered by the Warranty, the end user must take or send the unit to the Manufacturer or service partner at their own risk.
In the event of damage to the heat exchanger, the gas press- ure regulator, too, must be returned along with the unit.
Air conditioning systems:
To avoid transport damage, the unit must be sent either to the Truma Service Centre in Germany or to the relevant authorised service partner; this must only be done upon prior arrangement. Otherwise the sender shall bear the risk for any transport damage that may occur.
If a unit is sent to the manufacturing facility, make sure it is shipped as a freight item. If the claim is covered by the
Warranty, transport / shipping and the cost of return shall be borne by the manufacturing facility. If the claim is not covered by the Warranty, the Manufacturer shall notify the customer to this effect, specifying the cost of repairs not borne by the
Manufacturer; shipping costs, too, shall be borne by the customer in such a case.
5
Should problems occur, please contact the Truma
Service Centre or one of our authorised service partners (see www.truma.com).
In order to avoid delays, please have the unit model and serial number ready (see type plate).
Truma Gerätetechnik GmbH & Co. KG
Wernher-von-Braun-Straße 12
85640 Putzbrunn
Deutschland
Service
Telefon +49 (0)89 4617-2020
Telefax +49 (0)89 4617-2159 [email protected]
www.truma.com
Download
Advertisement