Raytheon Gyrostar 2 PLUS Package Operation Manual

Add to my manuals

advertisement

Raytheon Gyrostar 2 PLUS Package Operation Manual | Manualzz

R Raytheon Marine GmbH

High Seas Products

Postfach 1166

D -- 24100 Kiel

Germany

Tel +49--4 31--30 19--0

Fax +49--4 31--30 19--291

Email [email protected]

www.raytheon--marine.com

Gyro Compass GyroStar II

with:

Additional Configuration: PLUS PACKAGE

Additional Configuration: PLUS SEC PACKAGE

Additional Configuration: PLUS SYSTEM PACKAGE

Additional Configurations with:

-- Distributor Compact 110--224 NG001/NG002

-- Operator Unit 130--601/130--602/130--605

-- Control Unit GY01 or GY03

3673DOC000002 Edition: July 2003

Weitergabe sowie Vervielfältigung dieser Unterlage, Verwertung und

Mitteilung ihres Inhaltes nicht gestattet, soweit nicht ausdrücklich zugestanden. Zuwiderhandlungen verpflichten zu Schadenersatz.

Toute communication ou reproduction de ce document, toute exploitation ou communication de son contenu sont interdites, sauf autorisation expresse. Tout manquement à cette règle est illicite et expose son auteur au versement de dommages et intérêts.

Copying of this document, and giving it to others and the use or communication of the contents thereof, are forbidden without express authority. Offenders are liable to the payment of damages.

Sin nuestra expresa autorización, queda terminantemente prohibida la reproducción total o parcial de este documento, así como su uso indebido y/o su exhibición o comunicación a terceros. De los infractores se exigirá el correspondiente resarcimiento de daños y perjuicios.

GyroStar II PLUS...PACKAGE

COMPASS

Please note:

“GyroStar II” and “GyroStar II with PLUS...PACKAGE” are absolut identically compasses.

The different designations as there are “GyroStar II PLUS PACKAGE”, “GyroStar II PLUS

SEC PACKAGE“ and “GyroStar II PLUS SYSTEM PACKAGE” depends on the connected equipment.

The so called “stand--allone--system” is a GyroStar II with the equipment,

Junction box, type 138--113

Repeater compass, type 133--558 (optional)

AC/DC Converter, type 121--058 (optional)

Quick Settling control unit, type 130--606 NG001 (optional)

Dongles for QS and SEC (optional)

The compass GyroStar II additional configuration: “PLUS PACKAGE” is connected: via the Connection box, type 138--113 to the

Distributor Compact, type110--224 NG001 or NG002.

The compass GyroStar II additional configuration: “PLUS SEC PACKAGE” is connected: via the Connection box, type 138--113 to the

Distributor Compact, type110--224 NG001 or NG002

(with SEC--function) and with Operator Unit, type 130--601.

The compass GyroStar II additional configuration: “PLUS SYSTEM PACKAGE” is connected to: the Control Unit, type GY01 and the

Operator Unit, type 130--601/602/605

While connecting to the Control Unit and/or the Distributor Compact, there are restrictions depending on the Speed Error correction.

This GyroStar II “PLUS....PACKAGE”--family has no restrictions depending the size of a vessel.

Edition: July 2003

I

3673DOC000002

GyroStar II PLUS...PACKAGE

In general:

All designations “STANDARD 20“ and “STANDARD 20 PLUS” in this or appended manuals must be designated in the meaning of GyroStar II PLUS....PACKAGE.

For connecting a GyroStar II additional configuration: “PLUS PACKAGE” to a Distributor

Compact see drawings:

10--C0--D--X00009--C and Assembly drawing 110 C 231 HP010 in this manual.

For connecting a GyroStar II additional configuration: “PLUS SEC PACKAGE” to a

Distributor Compact see drawing:

10--C0--D--X00010--C and Assembly drawing 110 C 231 HP010 in this manual.

For connecting a GyroStar II additional configuration: “PLUS SYSTEM PACKAGE” to a

Control Unit see drawing 10--C90--D--X00011--C.

The connection of a GyroStar II additional configuration:

PLUS PACKAGE to a Control Unit and or to a

Distributor Compact is different to a connection of a

STANDARD 20 compass.

The operation is identical.

Restrictions on the combination of a GyroStar // PLUS...PACKAGE with a Control Unit and with a Distributor Compact are shown in the following sections.

3673DOC000002 II

Edition: July 2003

GyroStar II PLUS...PACKAGE

COMPASS

CONTENTS Page

1 Features of GyroStar II additional configuration: PLUS...PACKAGE--Family . . . . . . . . . . . . .

1.1

GyroStar II additional configuration: “PLUS PACKAGE” (Combination of GyroStar II with

Distributor Compact, type 110--224 NG001) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

1.1.1 Connections and jumpering hints . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

1.2

GyroStar II additional configuration: “PLUS SEC PACKAGE” (Combination of GyroStar II with Distributor Compact, type 110--224 NG002 and Operator Unit)

1.2.1 Connections and jumpering hints

. . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

1.3

GyroStar II additional configuration: “PLUS SYSTEM PACKAGE” (Combination of

GyroStar II with Control Unit, type GY01 and Operator Unit)

1.3.1 Connections hints

. . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

1

2

3

4

5

4

6

Annex: Drawings:

10--C0--D--X00009--C Cable and Connection Diagram

GyroStar II additional configuration: “PLUS PACKAGE” (GyroStar II with

Distributor Compact)

10--C0--D--X00010--C Cable and Connection Diagram

GyroStar II additional configuration: “PLUS SEC PACKAGE(GyroStar II with Distributor Compact and Operator Unit 130--601)

10--C0--D--X00011--C Cable and Connection Diagram

GyroStar II additional configuration: “PLUS SYSTEM PACKAGE”

(Gyro Star II with Control Unit GY... and

110 C 231 HP010

Operator Unit 130--601/130--602/130--605) Sheets 1 and 2

Assembly drawing for GyroStar II PLUS....PACKAGE

Additional manuals (depending on order--configuration):

Operator Manual 3125E.DOC012:

-- Gyro Compass Equipment STANDARD 20 PLUS

(Control Unit, type GY01 or GY03 and

Operator Unit STANDARD 20, type 130--601 E01)

Service Manual 3125EDOC032:

-- Gyro Compass Equipment STANDARD 20 PLUS

(Control Unit, type GY01 or GY03 and

Operator Unit STANDARD 20, type 130--601 E01)

Service Manual 3002E/100--224.NG001.DOC032

-- Distributor COMPACT, type 110--224 NG001

Edition: July 2003

III

3673DOC000002

GyroStar II PLUS...PACKAGE

Service Manual 3113E/110--224.NG002.DOC032

-- Distributor COMPACT wth Speed--error Correction, type 110--224 NG002

Operator Manual 3099E.DOC012

-- Gyro Compass Equipment STANDARD 20 COMPACT with Speed--error Correction

(Systemdescription)

Service Manual 3099E.DOC032

-- Gyro Compass Equipment STANDARD 20 COMPACT with Speed--error Correction

(Systemdescription)

Operator Manual 3165E.DOC012

-- Gyro Compass Equipment with

Control Unit GY01/GY03

Operator Unit TMC 130--605

Magnetic Sonde 108--010

(Systemdescription)

Service Manual 3165E.DOC032

-- Gyro Compass Equipment with

Control Unit GY01/GY03

Operator Unit TMC 130--605

Magnetic Sonde 108--010

(Systemdescription)

Operator Manual 3072E.DOC012

-- Gyro Compass Equipment with

Control Unit GY01/GY03

Operator Unit 130--601

Magnetic Sonde 108--010

Operator Unit 130--602

(Systemdescription)

Service Manual 3072E.DOC032

-- Gyro Compass Equipment with

Control Unit GY01/GY03

Operator Unit 130--601

Magnetic Sonde 108--010

Operator Unit 130--602

(Systemdescription)

3673DOC000002 IV

Edition: July 2003

GyroStar II PLUS...PACKAGE

COMPASS

1

Edition: July 2003

Features of GyroStar II PLUS...PACKAGE--Family

Some functions are restricted while connected to a Distributor Compact or a

Control Unit:

GyroStar II additional configuration: “PLUS SYSTEM PACKAGE” connected to a

Control Unit.

-- no dongles can be inserted (connection without Connection Box).

Speed Error Correction is performed via the Operator Unit.

GyroStar II additional configuration: ” PLUS SEC PACKAGE” connected to a

Distributor Compact, type 110--224

-- dongle for Quick Settling can be inserted into the Connection box, type138--113.

Speed Error Correction is performed via the Operator Unit.

GyroStar II additional configuration: “PLUS PACKAGE” connected to a

Distributor Compact, type 110--224

-- Because a connection of an Operator Unit the dongle for Quick settling function may be inserted into the junction box, type 138--113 (optional).

This GyroStar II additional configuration: “PLUS PACKAGE” has no

Speed Error Function.

In general it is not alowed to combine the power supply (24VDC) in another way, than shown in the drawings.

The power capacity of the Control Unit is able to supply one

GyroStar II additional configuration: “PLUS SYSTEM PACKAGE”, but the Distributor Compact has not enough power capacity to supply a GyroStar II additional configuration: “PLUS PACKAGE” or a GyroStar II additional configuration:

“PLUS SEC PACKAGE”.

Alarm indication and operating priciples of the GyroStar II additional configurations: “PLUS PACKAGE”, “PLUS SEC PACKAGE” or “PLUS SYSTEM PACK-

AGE” are not restricted.

1 3673DOC000002

GyroStar II PLUS...PACKAGE

1.1

GyroStar II additional configuration: “PLUS PACKAGE” (Combination of

GyroStar II with Distributor Compact, type 110--224 NG001)

A GyroStar II additional configuration: “PLUS PACKAGE” has to be connected to a Distributor Compact via the Junction box, type 138--113 (see also manual 3490

“GyroStar II”), drawing nos.: 10--C0--D--X00009--C and Assembly Drawing 110 C 231 HP010 in this manual.

GyroStar II additional configuration: “PLUS PACKAGE” connected to a Distributor Compact, type 110--224 NG001

Only the dongle for Quick Settling can be inserted into the

Junction Box, type 138--113.

Caution:

It is not allowed to insert a dongle for Speed Error

Correction into the Distribution Box 138--113

For alarm indication see operation manual 3490 ”GyroStar II”, section 4.

Operating principles for GyroStar // additional configuration: ”PLUS PACKAGE” and Distributor Compact are not resticted.

It is only allowd to connect the power supply for the GyroStar II additional configuration: “PLUS

PACKAGE” and the Distributor Compact as shown in the respective drawings in this manual.

3673DOC000002 2

Edition: July 2003

GyroStar II PLUS...PACKAGE

COMPASS

1.1.1

Connections and jumpering hints

1

3

5

1

3

5

2 Jumper

4 B10

Output 1 Format: course bus

6

2

4

B10

Output 1 Format: NMEA

6

B11 B10

Jumper setting for connecting GyroStar II additional configuration:

“PLUS PACKAGE”

5

1

3

1

3

5

2

4

6

2

4

6

Output 1:

Distributor Compact has to be connected to terminal strip as below mentioned:

Terminal strip L4 (see also Connection diagram for GyroStar II PLUS....PACK-

AGE in this manual):

Connection box

138--113

Terminal

Terminal

Terminal

1

2

14

Distributor Compact

110--224

L1.70

L1.42

L1.71

TX + (course data )

TX -- (course data )

TX GND (reference course data)

Edition: July 2003

3 3673DOC000002

GyroStar II PLUS...PACKAGE

1.2

GyroStar II additional configuration: “PLUS SEC PACKAGE” (Combination of GyroStar II with Distributor Compact, type 110--224 NG002 and

Operator Unit 130--601)

A GyroStar II additional configuration: “PLUS SEC PACKAGE” has to be connected to a Distributor Compact via the Junction box, type 138--113 (see also manual 3490 “GyroStar II”), drawing nos.: 10--C0--D--X00009--C and Assembly Drawing 110 C 231 HP010 in this manual.

GyroStar II additional configuration: “PLUS SEC PACKAGE” connected to a Distributor Compact, type 110--224 NG002 and Operator Unit 130--601

Only the dongle for Quick Settling can be inserted into the

Junction Box, type 138--113.

Caution:

It is not allowed to insert a dongle for Speed Error

Correction into the Distribution Box 138--113.

In this case the Speed Error Function is performed by the

Operator Unit.

For alarm indication see operation manual 3490 ”GyroStar II”, section 4.

Operating principles for GyroStar // additional configuration: ”PLUS SEC PACK-

AGE”, Distributor Compact and Operator Unit are not resticted.

It is only allowd to connect the power supply for the GyroStar II additional configuration:

“PLUS SEC PACKAGE” and the Distributor

Compact as shown respective drawings in this manual.

3673DOC000002 4

Edition: July 2003

GyroStar II PLUS...PACKAGE

COMPASS

1.2.1

Connections and jumpering hints

1

3

5

1

3

5

2 Jumper

4 B10

Output 1 Format: course bus

6

2

4

B10

Output 1 Format: NMEA

6

B11 B10

Jumper setting for GyroStar II additional configuration:

“PLUS SEC PACKAGE”

5

1

3

1

3

5

2

4

6

2

4

6

Output 1:

Distributor Compact has to be connected to terminal strip as below mentioned:

Terminal strip L4 (see also Connection diagram for GyroStar II additional configurations: “PLUS....PACKAGE” in this manual):

Connection box

138--113

Terminal

Terminal

Terminal

1

2

14

Distributor Compact

110--224

L1.70

L1.42

L1.71

TX + (course data )

TX -- (course data )

TX GND (reference course data)

Edition: July 2003

5 3673DOC000002

GyroStar II PLUS...PACKAGE

1.3

1.3.1

GyroStar II additional configuration:“PLUS SYSTEM PACKAGE”

(Combination of GyroStar II with Control Unit GY01 and

Operator Unit 130--601/130--602/130--605)

A GyroStar II additional configuration: PLUS SYSTEM PACKAGE” has to be connected to a Control Unit with cable no.: NB60--125 see drawing no.: 10--C0--D--X00011--C.

For alarm indication see operation manual 3490 ”GyroStar II”, section 4.

Operating principles for GyroStar //, Control Unit and respective Operation Unit are not resticted.

Connections hints

Data

Control Unit GY01 cable NB60--1258

Power

3673DOC000002 6

Edition: July 2003

GyroStar II PLUS...PACKAGE

COMPASS

Connection hints for Gyro 1

GyroStar II additional configuration:

“PLUS SYSTEM

PACKAGE”

Plug B100

Control Unit GY01

(Transfer Module

STD 20, U22)

Below mentioned connections are performed via the cable NB60--125 with plugs on both ends

Terminal 5

Terminal 24

Modul U22

Plug B11

Terminal 2

Modul U22, Plug B11,

Terminal 1

Control Unit GY01

Terminal board L2

TX + (course data )

TX -- (course data )

GyroStar II additional configuration:

“PLUS SYSTEM

PACKAGE”

Plug B100

Below mentioned connections are performed via the cable NB60--125 by screwing at terminals

Terminals 17,37,36 or 18 Terminal board L2

Terminal 31

+ 24VDC

Terminals 15,34,16, or 35 Terminal board L2

Terminal 12

(0V)

Cable screen has to be connected at ( ) of terminal board L2 of the Control

Unit.

Edition: July 2003

7 3673DOC000002

GyroStar II PLUS...PACKAGE

Connection hints for Gyro 2

GyroStar II additional configuration:

“PLUS SYSTEM

PACKAGE”

Plug B100

Control Unit GY01

(Transfer Module

STD 20, U22)

Below mentioned connections are performed via the cable NB60--125 with plugs on both ends

Terminal 5 Modul U22, Plug B13

Terminal 2

TX + (course data )

Terminal 24

GyroStar II additional configuration:

“PLUS SYSTEM

PACKAGE”

Plug B100

Modul U22, Plug B13,

Terminal 1

Control Unit Gx01 o

Terminal board L2

TX -- (course data )

Below mentioned connections are performed via the cable NB60--125 by screwing at terminals

Terminals 17,37,36 or 18 Terminal board L2

Terminal 33

Terminals 15,34,16, or 35 Terminal board L2

Terminal 14

+ 24VDC

(0V)

Cable screen has to be connected at ( ) of terminal board L2 of the Control

Unit.

3673DOC000002 8

Edition: July 2003

L2.2

L2.3

L1.71

L1.42

L1.70

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement