- Computers & electronics
- Audio & home theatre
- Video converters
- Raytheon
- Gyrostar 2 PLUS Package
- Operation manual
Raytheon Gyrostar 2 PLUS Package Operation Manual
Add to my manualsRaytheon Gyrostar 2 PLUS Package is a versatile gyro compass system designed for marine navigation. It combines advanced technology with user-friendly features to provide precise heading and course information for various types of vessels. With its compact size and easy installation, the Gyrostar 2 PLUS Package is suitable for a wide range of applications, including yachts, fishing boats, and commercial ships.
advertisement
R Raytheon Marine GmbH
High Seas Products
Postfach 1166
D -- 24100 Kiel
Germany
Tel +49--4 31--30 19--0
Fax +49--4 31--30 19--291
Email [email protected]
www.raytheon--marine.com
Gyro Compass GyroStar II
with:
Additional Configuration: PLUS PACKAGE
Additional Configuration: PLUS SEC PACKAGE
Additional Configuration: PLUS SYSTEM PACKAGE
Additional Configurations with:
-- Distributor Compact 110--224 NG001/NG002
-- Operator Unit 130--601/130--602/130--605
-- Control Unit GY01 or GY03
3673DOC000002 Edition: July 2003
Weitergabe sowie Vervielfältigung dieser Unterlage, Verwertung und
Mitteilung ihres Inhaltes nicht gestattet, soweit nicht ausdrücklich zugestanden. Zuwiderhandlungen verpflichten zu Schadenersatz.
Toute communication ou reproduction de ce document, toute exploitation ou communication de son contenu sont interdites, sauf autorisation expresse. Tout manquement à cette règle est illicite et expose son auteur au versement de dommages et intérêts.
Copying of this document, and giving it to others and the use or communication of the contents thereof, are forbidden without express authority. Offenders are liable to the payment of damages.
Sin nuestra expresa autorización, queda terminantemente prohibida la reproducción total o parcial de este documento, así como su uso indebido y/o su exhibición o comunicación a terceros. De los infractores se exigirá el correspondiente resarcimiento de daños y perjuicios.
GyroStar II PLUS...PACKAGE
COMPASS
Please note:
“GyroStar II” and “GyroStar II with PLUS...PACKAGE” are absolut identically compasses.
The different designations as there are “GyroStar II PLUS PACKAGE”, “GyroStar II PLUS
SEC PACKAGE“ and “GyroStar II PLUS SYSTEM PACKAGE” depends on the connected equipment.
The so called “stand--allone--system” is a GyroStar II with the equipment,
Junction box, type 138--113
Repeater compass, type 133--558 (optional)
AC/DC Converter, type 121--058 (optional)
Quick Settling control unit, type 130--606 NG001 (optional)
Dongles for QS and SEC (optional)
The compass GyroStar II additional configuration: “PLUS PACKAGE” is connected: via the Connection box, type 138--113 to the
Distributor Compact, type110--224 NG001 or NG002.
The compass GyroStar II additional configuration: “PLUS SEC PACKAGE” is connected: via the Connection box, type 138--113 to the
Distributor Compact, type110--224 NG001 or NG002
(with SEC--function) and with Operator Unit, type 130--601.
The compass GyroStar II additional configuration: “PLUS SYSTEM PACKAGE” is connected to: the Control Unit, type GY01 and the
Operator Unit, type 130--601/602/605
While connecting to the Control Unit and/or the Distributor Compact, there are restrictions depending on the Speed Error correction.
This GyroStar II “PLUS....PACKAGE”--family has no restrictions depending the size of a vessel.
Edition: July 2003
I
3673DOC000002
GyroStar II PLUS...PACKAGE
In general:
All designations “STANDARD 20“ and “STANDARD 20 PLUS” in this or appended manuals must be designated in the meaning of GyroStar II PLUS....PACKAGE.
For connecting a GyroStar II additional configuration: “PLUS PACKAGE” to a Distributor
Compact see drawings:
10--C0--D--X00009--C and Assembly drawing 110 C 231 HP010 in this manual.
For connecting a GyroStar II additional configuration: “PLUS SEC PACKAGE” to a
Distributor Compact see drawing:
10--C0--D--X00010--C and Assembly drawing 110 C 231 HP010 in this manual.
For connecting a GyroStar II additional configuration: “PLUS SYSTEM PACKAGE” to a
Control Unit see drawing 10--C90--D--X00011--C.
The connection of a GyroStar II additional configuration:
PLUS PACKAGE to a Control Unit and or to a
Distributor Compact is different to a connection of a
STANDARD 20 compass.
The operation is identical.
Restrictions on the combination of a GyroStar // PLUS...PACKAGE with a Control Unit and with a Distributor Compact are shown in the following sections.
3673DOC000002 II
Edition: July 2003
GyroStar II PLUS...PACKAGE
COMPASS
CONTENTS Page
1 Features of GyroStar II additional configuration: PLUS...PACKAGE--Family . . . . . . . . . . . . .
1.1
GyroStar II additional configuration: “PLUS PACKAGE” (Combination of GyroStar II with
Distributor Compact, type 110--224 NG001) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1.1.1 Connections and jumpering hints . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1.2
GyroStar II additional configuration: “PLUS SEC PACKAGE” (Combination of GyroStar II with Distributor Compact, type 110--224 NG002 and Operator Unit)
1.2.1 Connections and jumpering hints
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1.3
GyroStar II additional configuration: “PLUS SYSTEM PACKAGE” (Combination of
GyroStar II with Control Unit, type GY01 and Operator Unit)
1.3.1 Connections hints
. . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1
2
3
4
5
4
6
Annex: Drawings:
10--C0--D--X00009--C Cable and Connection Diagram
GyroStar II additional configuration: “PLUS PACKAGE” (GyroStar II with
Distributor Compact)
10--C0--D--X00010--C Cable and Connection Diagram
GyroStar II additional configuration: “PLUS SEC PACKAGE” (GyroStar II with Distributor Compact and Operator Unit 130--601)
10--C0--D--X00011--C Cable and Connection Diagram
GyroStar II additional configuration: “PLUS SYSTEM PACKAGE”
(Gyro Star II with Control Unit GY... and
110 C 231 HP010
Operator Unit 130--601/130--602/130--605) Sheets 1 and 2
Assembly drawing for GyroStar II PLUS....PACKAGE
Additional manuals (depending on order--configuration):
Operator Manual 3125E.DOC012:
-- Gyro Compass Equipment STANDARD 20 PLUS
(Control Unit, type GY01 or GY03 and
Operator Unit STANDARD 20, type 130--601 E01)
Service Manual 3125EDOC032:
-- Gyro Compass Equipment STANDARD 20 PLUS
(Control Unit, type GY01 or GY03 and
Operator Unit STANDARD 20, type 130--601 E01)
Service Manual 3002E/100--224.NG001.DOC032
-- Distributor COMPACT, type 110--224 NG001
Edition: July 2003
III
3673DOC000002
GyroStar II PLUS...PACKAGE
Service Manual 3113E/110--224.NG002.DOC032
-- Distributor COMPACT wth Speed--error Correction, type 110--224 NG002
Operator Manual 3099E.DOC012
-- Gyro Compass Equipment STANDARD 20 COMPACT with Speed--error Correction
(Systemdescription)
Service Manual 3099E.DOC032
-- Gyro Compass Equipment STANDARD 20 COMPACT with Speed--error Correction
(Systemdescription)
Operator Manual 3165E.DOC012
-- Gyro Compass Equipment with
Control Unit GY01/GY03
Operator Unit TMC 130--605
Magnetic Sonde 108--010
(Systemdescription)
Service Manual 3165E.DOC032
-- Gyro Compass Equipment with
Control Unit GY01/GY03
Operator Unit TMC 130--605
Magnetic Sonde 108--010
(Systemdescription)
Operator Manual 3072E.DOC012
-- Gyro Compass Equipment with
Control Unit GY01/GY03
Operator Unit 130--601
Magnetic Sonde 108--010
Operator Unit 130--602
(Systemdescription)
Service Manual 3072E.DOC032
-- Gyro Compass Equipment with
Control Unit GY01/GY03
Operator Unit 130--601
Magnetic Sonde 108--010
Operator Unit 130--602
(Systemdescription)
3673DOC000002 IV
Edition: July 2003
GyroStar II PLUS...PACKAGE
COMPASS
1
Edition: July 2003
Features of GyroStar II PLUS...PACKAGE--Family
Some functions are restricted while connected to a Distributor Compact or a
Control Unit:
GyroStar II additional configuration: “PLUS SYSTEM PACKAGE” connected to a
Control Unit.
-- no dongles can be inserted (connection without Connection Box).
Speed Error Correction is performed via the Operator Unit.
GyroStar II additional configuration: ” PLUS SEC PACKAGE” connected to a
Distributor Compact, type 110--224
-- dongle for Quick Settling can be inserted into the Connection box, type138--113.
Speed Error Correction is performed via the Operator Unit.
GyroStar II additional configuration: “PLUS PACKAGE” connected to a
Distributor Compact, type 110--224
-- Because a connection of an Operator Unit the dongle for Quick settling function may be inserted into the junction box, type 138--113 (optional).
This GyroStar II additional configuration: “PLUS PACKAGE” has no
Speed Error Function.
In general it is not alowed to combine the power supply (24VDC) in another way, than shown in the drawings.
The power capacity of the Control Unit is able to supply one
GyroStar II additional configuration: “PLUS SYSTEM PACKAGE”, but the Distributor Compact has not enough power capacity to supply a GyroStar II additional configuration: “PLUS PACKAGE” or a GyroStar II additional configuration:
“PLUS SEC PACKAGE”.
Alarm indication and operating priciples of the GyroStar II additional configurations: “PLUS PACKAGE”, “PLUS SEC PACKAGE” or “PLUS SYSTEM PACK-
AGE” are not restricted.
1 3673DOC000002
GyroStar II PLUS...PACKAGE
1.1
GyroStar II additional configuration: “PLUS PACKAGE” (Combination of
GyroStar II with Distributor Compact, type 110--224 NG001)
A GyroStar II additional configuration: “PLUS PACKAGE” has to be connected to a Distributor Compact via the Junction box, type 138--113 (see also manual 3490
“GyroStar II”), drawing nos.: 10--C0--D--X00009--C and Assembly Drawing 110 C 231 HP010 in this manual.
GyroStar II additional configuration: “PLUS PACKAGE” connected to a Distributor Compact, type 110--224 NG001
Only the dongle for Quick Settling can be inserted into the
Junction Box, type 138--113.
Caution:
It is not allowed to insert a dongle for Speed Error
Correction into the Distribution Box 138--113
For alarm indication see operation manual 3490 ”GyroStar II”, section 4.
Operating principles for GyroStar // additional configuration: ”PLUS PACKAGE” and Distributor Compact are not resticted.
It is only allowd to connect the power supply for the GyroStar II additional configuration: “PLUS
PACKAGE” and the Distributor Compact as shown in the respective drawings in this manual.
3673DOC000002 2
Edition: July 2003
GyroStar II PLUS...PACKAGE
COMPASS
1.1.1
Connections and jumpering hints
1
3
5
1
3
5
2 Jumper
4 B10
Output 1 Format: course bus
6
2
4
B10
Output 1 Format: NMEA
6
B11 B10
Jumper setting for connecting GyroStar II additional configuration:
“PLUS PACKAGE”
5
1
3
1
3
5
2
4
6
2
4
6
Output 1:
Distributor Compact has to be connected to terminal strip as below mentioned:
Terminal strip L4 (see also Connection diagram for GyroStar II PLUS....PACK-
AGE in this manual):
Connection box
138--113
Terminal
Terminal
Terminal
1
2
14
Distributor Compact
110--224
L1.70
L1.42
L1.71
TX + (course data )
TX -- (course data )
TX GND (reference course data)
Edition: July 2003
3 3673DOC000002
GyroStar II PLUS...PACKAGE
1.2
GyroStar II additional configuration: “PLUS SEC PACKAGE” (Combination of GyroStar II with Distributor Compact, type 110--224 NG002 and
Operator Unit 130--601)
A GyroStar II additional configuration: “PLUS SEC PACKAGE” has to be connected to a Distributor Compact via the Junction box, type 138--113 (see also manual 3490 “GyroStar II”), drawing nos.: 10--C0--D--X00009--C and Assembly Drawing 110 C 231 HP010 in this manual.
GyroStar II additional configuration: “PLUS SEC PACKAGE” connected to a Distributor Compact, type 110--224 NG002 and Operator Unit 130--601
Only the dongle for Quick Settling can be inserted into the
Junction Box, type 138--113.
Caution:
It is not allowed to insert a dongle for Speed Error
Correction into the Distribution Box 138--113.
In this case the Speed Error Function is performed by the
Operator Unit.
For alarm indication see operation manual 3490 ”GyroStar II”, section 4.
Operating principles for GyroStar // additional configuration: ”PLUS SEC PACK-
AGE”, Distributor Compact and Operator Unit are not resticted.
It is only allowd to connect the power supply for the GyroStar II additional configuration:
“PLUS SEC PACKAGE” and the Distributor
Compact as shown respective drawings in this manual.
3673DOC000002 4
Edition: July 2003
GyroStar II PLUS...PACKAGE
COMPASS
1.2.1
Connections and jumpering hints
1
3
5
1
3
5
2 Jumper
4 B10
Output 1 Format: course bus
6
2
4
B10
Output 1 Format: NMEA
6
B11 B10
Jumper setting for GyroStar II additional configuration:
“PLUS SEC PACKAGE”
5
1
3
1
3
5
2
4
6
2
4
6
Output 1:
Distributor Compact has to be connected to terminal strip as below mentioned:
Terminal strip L4 (see also Connection diagram for GyroStar II additional configurations: “PLUS....PACKAGE” in this manual):
Connection box
138--113
Terminal
Terminal
Terminal
1
2
14
Distributor Compact
110--224
L1.70
L1.42
L1.71
TX + (course data )
TX -- (course data )
TX GND (reference course data)
Edition: July 2003
5 3673DOC000002
GyroStar II PLUS...PACKAGE
1.3
1.3.1
GyroStar II additional configuration:“PLUS SYSTEM PACKAGE”
(Combination of GyroStar II with Control Unit GY01 and
Operator Unit 130--601/130--602/130--605)
A GyroStar II additional configuration: PLUS SYSTEM PACKAGE” has to be connected to a Control Unit with cable no.: NB60--125 see drawing no.: 10--C0--D--X00011--C.
For alarm indication see operation manual 3490 ”GyroStar II”, section 4.
Operating principles for GyroStar //, Control Unit and respective Operation Unit are not resticted.
Connections hints
Data
Control Unit GY01 cable NB60--1258
Power
3673DOC000002 6
Edition: July 2003
GyroStar II PLUS...PACKAGE
COMPASS
Connection hints for Gyro 1
GyroStar II additional configuration:
“PLUS SYSTEM
PACKAGE”
Plug B100
Control Unit GY01
(Transfer Module
STD 20, U22)
Below mentioned connections are performed via the cable NB60--125 with plugs on both ends
Terminal 5
Terminal 24
Modul U22
Plug B11
Terminal 2
Modul U22, Plug B11,
Terminal 1
Control Unit GY01
Terminal board L2
TX + (course data )
TX -- (course data )
GyroStar II additional configuration:
“PLUS SYSTEM
PACKAGE”
Plug B100
Below mentioned connections are performed via the cable NB60--125 by screwing at terminals
Terminals 17,37,36 or 18 Terminal board L2
Terminal 31
+ 24VDC
Terminals 15,34,16, or 35 Terminal board L2
Terminal 12
(0V)
Cable screen has to be connected at ( ) of terminal board L2 of the Control
Unit.
Edition: July 2003
7 3673DOC000002
GyroStar II PLUS...PACKAGE
Connection hints for Gyro 2
GyroStar II additional configuration:
“PLUS SYSTEM
PACKAGE”
Plug B100
Control Unit GY01
(Transfer Module
STD 20, U22)
Below mentioned connections are performed via the cable NB60--125 with plugs on both ends
Terminal 5 Modul U22, Plug B13
Terminal 2
TX + (course data )
Terminal 24
GyroStar II additional configuration:
“PLUS SYSTEM
PACKAGE”
Plug B100
Modul U22, Plug B13,
Terminal 1
Control Unit Gx01 o
Terminal board L2
TX -- (course data )
Below mentioned connections are performed via the cable NB60--125 by screwing at terminals
Terminals 17,37,36 or 18 Terminal board L2
Terminal 33
Terminals 15,34,16, or 35 Terminal board L2
Terminal 14
+ 24VDC
(0V)
Cable screen has to be connected at ( ) of terminal board L2 of the Control
Unit.
3673DOC000002 8
Edition: July 2003
L2.2
L2.3
L1.71
L1.42
L1.70
advertisement