Hafele 372.96.000 Lift System Instructions


Add to my manuals
28 Pages

advertisement

Hafele 372.96.000 Lift System Instructions | Manualzz

WIND

WIND

The Wind lift system is characterized by compactness and elegant design.

Its movement is smooth and perfectly controlled. Wind is small and unobtrusive, enabling the maximum utilization of cabinet internal space. Suitable for Kitchen cabinets, living room or bedroom furniture and office furniture.

In the kitchen environment, Wind has strong functional appeal - a compact adjustable lift system that takes up a minimum of valuable storage space.

Aesthetics also play a key role with Wind’s small size and streamlined shape adding significantly to the overall appeal of the cabinets to which it is installed.

Wind is available in a range of attractive finishes designed to complement the vast range of cabinet applications that it can be used for.

Wind Lift system is a simple program that covers a large variety of door sizes.

3

Wind

Technical information

Flap door lift system fixed to the cabinet sides.

Drilling of the door ø35.

13 mm deep cup.

85° opening with stop device (premounted).

94° opening without stop device.

Minimum door height 220mm / 8-5/8”

Maximum door height 610mm / 24”

Possible drilling distance on the door (K): from 3 to 7 mm.

CARATTERISTICA = 13

APERTURA MASSIMA = 94°

FORATURA SCATOLA Ø35X13

REGOLAZIONE VERTICALE = -2 +2

REGOLAZIONE FRONTALE = -1 +3

REGOLAZIONE LATERALE = -2 +2

Drilling pattern - Dimensions Frameless

Side view

33

ø5x13

Top View

ø 35

13

104

46 17.5 + K

K 3 - 7

55

177

Cabinet side

18

K = Drilling distance

D = Door overlay on the cabinet side

D

24

19

8.5

21

8.5+D

19+D

ø5x13

Space needed to open the door

A min.

D1

4

57

202

MINIMUM REVEAL TABLE

T= 16 17 18 19 20 21 22 23 24 25 26 27 28

K=3 A= 0 0.1

0.1

0.2

0.2

0.3

0.5

0.6

0.7

0.9

1.1

1.8

2.7

K=4 A=

K=5 A=

K=6 A=

0

0

0

0.1

0.1

0.1

0.1

0.1

0.1

0.2

0.2

0.2

0.2

0.2

0.2

0.3

0.3

0.3

0.4

0.4

0.4

0.6

0.6

0.6

0.7

0.7

0.7

0.9

0.9

0.9

1.1

1.1

1.0

1.3

1.3

1.2

2.1

1.5

1.5

K=7 A= 0 0.1

0.1

0.2

0.2

0.3

0.4

0.6

0.7

0.8

1.0

1.2

1.4

T

85°

OVERLAY TABLE

K

3

4

=

=

D1

16

17

5

6

7

= 18

= 19

= 20

K = Drilling distance

D1 = Door overlay on the cabinet top

A = Min Reveal

Drilling pattern - Dimensions - Frame

Side View

55

33

ø 35

200

104

174

46

55

13

K

17.5 + K

15

K = Drilling distance

D = Door overlay on the cabinet side

Top View

TH Frame recess

19

FILLER 2-3/16” x 7-7/8”

TH

D 24

8.5

8.5+D

21

19+D

Holes can be pre-drilled

5 mm dia or pilot drilled

2 mm dia.

Space needed to open the door

D1

Wind “Footprint” dimensions= 7-3/4” L x 2-1/4” H x 1-1/2” T

T

85° OVERLAY TABLE

4

5

K

3

6

7

=

=

=

=

=

D1

16

17

18

19

20

K = Drilling distance

D1 = Door overlay on the cabinet top

5

WIND -

Assembly instructions

Attaching the base to the cabinet sides

Use 5mm x 13mm system screws or #7 x 5/8” wood screws.

FRAME

Installing the cups to the door

Left Right

FRAMELESS

Left Right

FRAME

Connecting the lift mechanism to the cups

This operation is tool free.

FRAMELESS

Note:

LH lift mechanism must be installed in LH base,

RH lift mechanism must be installed in RH base.

SNAP ON

Left Right

FRAMELESS

SNAP ON

Left Right

6

FRAME

Connecting the lift system to the base

This operation is tool free.

FRAME

Installing the covers

SNAP ON

FRAMELESS

SNAP ON

FRAME FRAMELESS

7

WIND -

Adjustments

WARNING ! Security cable ties.

Remove the cable ties only at the end of the assembly.

Use the instructions and the QR Code attached to the systems.

Adjustments.

1 - adjustment of the spring strength.

2 - adjustment of the decelerating effect.

3 - removal of the angle reduction clip.

85°

85°

With stop device (premounted)

94°

94°

Without stop device

3

1

4 - height adjustment of the door from - 2 to +2.

5 - side adjustment of the door from - 2 to +2.

6 - depth adjustment of the door from - 1 to +3.

2

4

5

8

Note:

LH lift mechanism must be installed in LH base,

RH lift mechanism must be installed in RH base.

6

Disassembly instructions

Removal of the covers

FRAME FRAMELESS

Disassembly of the system

Press the back lever and remove the lift mechanism. This operation is tool free.

FRAME

Remove the lift mechanism from the cups (door)

Disconnecting the system from the cups. This operation is tool free.

FRAMELESS

FRAME FRAMELESS

9

Wind -

Optional top mount bracket

Technical information

Bracket to be attached to the top of the cabinet for use with:

• angled cabinets

• wide or heavier doors

• 5 piece doors

Note: When using the top mount bracket, the overlay is reduced by

3mm. Refer to the overlay chart below.

Drilling pattern.

Top

32 32 32 32 40

Space needed to open the door.

D1

A min.

10

5

6

7

K D1

3 = 13

4 = 14

=

=

=

15

16

17

85°

T

T=

K=3 A = min

K=4 A = min

K=5 A = min

K=6 A = min

K=7 A = min

0

0

0

16 17 18 19 20 21 22 23 24 25 26 27 28

0 0.1

0.1

0.2

0.2

0.3

0.5

0.6

0.7

0.9

1.1

1.8

2.7

0 0.1

0.1

0.2

0.2

0.3

0.4

0.6

0.7

0.9

1.1

1.3

2.1

0.1

0.1

0.1

0.1

0.1

0.1

0.2

0.2

0.2

0.2

0.2

0.2

0.3

0.3

0.3

0.4

0.4

0.4

0.6

0.6

0.6

0.7

0.7

0.7

0.9

0.9

0.8

1.1

1.0

1.0

1.3

1.2

1.2

1.5

1.5

1.4

Assembly instructions for the brackets

Attaching the brackets to the top of the cabinet.

Attach with five #8 x 5/8” wood screws provided

Attaching the base to the top bracket.

Attach with the 3 machine screws provided.

Connecting the lift system to the base.

This operation is tool free.

Installing the covers.

11

Wind -

Disassembly instructions for the top mount brackets

Removal of the covers.

Disassembly of the system.

Press the back lever and remove the lift system.

This operation is tool free.

Remove the base from the bracket.

Remove the screws and the bracket.

12

Top mount bracket applications

For cabinets that require a third system. For wide cabinet applications without a center partition.

The maximum door width for two Wind is 1200mm/48”

Note: Wind can be used on doors that are larger or heavier by adding additional Wind lifts to the cabinet and door.

This can be done by installing a center partition and adding additional Wind lifts or by utilizing the Top Mount Brackets with additional Wind lifts.

For all applications requiring more than two Wind lifts, check the Wind charts on pages 19 & 20.

Please consult with your local sales representative or contact technical service.

5

6

7

K

3

4

D1

= 13

= 14

= 15

= 16

= 17

For angled cabinets.

3

3

The bracket has a thickness of 3 mm and the cabinet side drilling must be lowered by 3mm. The Wind covers are adjustable and can be positioned to cover the 3mm space at the top.

49

36

36

18 55

49

104

18 55 104

K

5

6

3

4

7

D1

= 13

= 14

= 15

= 16

= 17

13

SRXA78AMSNXX_

Gray

Nickel-plated cover cap

SRXA78A0SNXX_

Satin metal black

Titanium cover cap

SRXA78ACSNXX_

Champagne

Nickel-plated cover cap

14

Wind -

Cover finishes for the cabinet base

SRXA78A1SNXX_

White

Nickel-plated cover cap

SRXA78AQSNXX_

Glossy white

Nickel-plated cover cap

SRXA78AISNXX_

Stainless steel

Nickel-plated cover cap

SRXA78ANSNXX_

Glossy metal black

Titanium cover cap

Cover finishes for the Top mount bracket

SRUA78A1SNXXI

White

SRUA78AQSNXXI

Glossy white

SRUA78AMSNXXI

Gray

SRUA78AISNXXI

Stainless steel

SRUA78ANSNXXI

Glossy metal black

SRUA78A0SNXXI

Satin metal black

SRUA78ACSNXXI

Champagne

15

WIND

- Packaging

KIT PACKAGING

PUSH

INDUSTRIAL PACKAGING

PART NUMBER

SOFT CLOSE

FRAKFEX_SN9

SPRING FORCE

See page 18 and 19 for the appropriate spring package letter

PUSH OPENING

FRAKFEP_SN9

SPRING FORCE

See page 18 and 19 for the appropriate spring package letter

PART NUMBER

PACKAGING

One box contains:

2 hinge cups

1 Right hand lift mechanism

1 Left hand lift mechanism

1 Right hand cabinet base

1 Left hand cabinet base

Includes 5mm x 13mm system screws

Note : #7 x 5/8” wood screws can also be used

PACKAGING

SOFT CLOSE

FRAKINX_SN9

SPRING FORCE

PUSH OPENING

FRAKINP_SN9

SPRING FORCE

One box contains:

18 Hinge cups

9 Right hand lift mechanisms

9 Left hand lift mechanisms

9 Right hand cabinet bases

9 Left hand cabinet bases

Includes 5mm x 13mm system screws

Note : #7 x 5/8” wood screws can also be used

PUSH

COVERS PART NUMBER

KIT PACKAGING

SRXA78A_SNXXF

COVER COLOR

See page 14 for the appropriate cover number

INDUSTRIAL PACKAGING

SRXA78A_SNXXI

COVER COLOR

See page 14 for the appropriate cover number

PACKAGING

One box contains:

1 Right hand cover

1 Left hand cover

Includes cover caps

Note: can be personalized

One box contains:

9 Right hand covers

9 Left hand covers

Includes cover caps

Note: can be personalized

16

KIT-SET PACKING

BRACKET AND COVER

PART NUMBER PACKAGING

FRAUFEXXXX_

COLOR OF

THE COVER

1 carton contains:

2 brackets

2 covers for the brackets

Wood screws to install the bracket and machine screws to attach the base are included.

INDUSTRIAL PACKAGING

TOP MOUNT BRACKET

PART NUMBER PACKAGING

FRAUINXXXX5

1 carton contains:

18 brackets

Wood screws to install the bracket and machine screws to attach the base are included.

INDUSTRIAL PACKAGING

COVER FOR THE BRACKET

PART NUMBER PACKAGING

SRUA78A_SNXXI

COLOR OF

THE COVER

1 carton contains:

18 covers for the brackets

17

8

7

0.8

0.6

0.4

0.2

0.6

0.4

0.2

6

0.8

0.6

0.4

0.2

5

0.8

0.6

0.4

0.2

4

0.8

0.6

0.4

0.2

3

0.8

0.4

0.6

Wind

2

-

Charts and

Spring force identification

0.8

0.2

0.6

0.4

0.2

1

FRAK

03

XXSN_ include the weight of the decorative hardware. The maximum door width for two Wind lifts is 1200mm/48”.

Note: Wind can be used on doors that are larger or heavier by adding additional Wind lifts to the cabinet and door. This can be done by installing a center partition and adding additional Wind lifts or by utilizing the Top Mount Brackets with additional Wind lifts.

For all applications requiring more than two Wind lifts, check the Wind charts on pages 19 & 20. Please consult with your local sales representative or contact technical service.

6

0.8

0.6

0.4

0.2

5

0.8

0.4

0.6

0.2

4

0.8

0.6

0.4

0.2

3

0.8

0.4

0.6

0.2

2

1

0.8

0.6

0.4

0.2

220 280 320 360 400 440

Door height (mm)

480 520

Min door height - 8-5/8”

Max door height - 15-3/4”

FRAK

03

XXSN_

18

8

0.8

0.6

0.4

0.2

7

0.6

0.4

0.2

6

0.8

0.6

0.4

0.2

5

0.8

0.6

0.4

0.2

4

0.8

0.6

0.4

0.2

3

0.8

0.6

0.4

2

0.8

0.2

0.6

0.4

0.2

1

220 280 320 360 400 440 480

Door height (mm)

520 560 600

Min door height - 8-5/8”

Max door height - 24”

Door height (mm)

15

0.8

0.6

0.4

0.2

14

0.8

0.6

0.4

0.2

13

0.8

0.6

0.4

0.2

12

0.8

0.6

0.4

0.2

11

0.8

0.6

0.4

0.2

10

0.8

0.4

0.6

0.2

9

0.8

0.6

0.4

0.2

8

0.8

0.4

0.6

0.2

7

0.8

0.6

0.4

0.2

6

0.8

0.6

0.4

0.2

5

0.8

0.6

0.4

0.2

4

0.8

0.6

0.4

0.2

3

0.8

0.6

0.4

0.2

2

320 360 400 440 480 520 560 600

Door height (mm)

Min door height - 12-9/16”

Max door height - 24”

4 WIND

3 WIND

2 WIND

FRAK

N

XXSN_

20

0.8

0.6

0.4

19

0.2

0.8

0.6

0.4

0.2

18

0.8

0.6

0.4

0.2

17

0.8

0.6

0.4

0.2

16

0.8

0.6

0.4

0.2

15

0.8

0.6

0.4

0.2

14

0.8

0.6

0.4

0.2

13

0.8

0.6

0.4

0.2

12

0.8

0.6

0.4

0.2

11

0.8

0.6

0.4

0.2

10

0.8

0.6

0.4

0.2

9

0.8

0.6

0.4

0.2

8

0.8

0.6

0.4

0.2

7

0.8

0.6

0.4

0.2

6

0.8

0.6

0.4

0.2

5

0.8

0.6

0.4

4

4 WIND

3 WIND

2 WIND

320 360 400 440 480 520 560 600

Min door height - 12-9/16”

Max door height - 24”

FRAK

F

XXSN_

19

Wind

-

Charts and

Spring force identification

24

0.8

0.4

0.2

23

0.8

0.6

0.4

0.2

22

0.8

0.6

0.4

0.2

21

0.8

0.6

0.4

20

0.8

0.2

0.6

0.4

0.2

19

0.8

0.6

0.4

0.2

18

0.8

0.6

0.4

0.2

17

0.8

0.6

0.4

0.2

16

0.8

0.6

0.4

0.2

15

0.8

0.6

0.4

0.2

14

0.8

0.6

0.4

0.6

0.2

13

0.8

0.6

0.4

0.2

12

0.8

0.6

0.4

0.2

11

0.8

0.6

0.4

0.2

10

0.8

0.6

0.4

0.2

9

0.8

0.6

0.4

0.2

8

0.8

0.6

0.4

0.2

7

0.8

0.6

0.4

0.2

6

320 360 400 440 480 520 560

Door height (mm)

600

Min door height - 12-9/16”

Max door height - 24”

4 WIND

3 WIND

2 WIND

FRAK

S

XXSN_

20

Magnetic Push

21

Magnetic Push

- Release device and retaining catches

DPMSNB

- beige

DPMSNG

- gray

Release device.

ø 10 mm, 40 mm length.

DPASNB

- beige

DP39XXG

DP28SN9

DP38XX91

DPASNG

- gray

Packing

Box 250 pieces

Carton 1.500 pieces

Magnetic device to be used to increase the magnetic holding strength. It must always be used together with the DPM. The suggested position of the DPM is the point of pressure on the door. The DPA can be positioned at any point along the opening edge of the door.

ø 10 mm, 40 mm length.

Packing

Box 250 pieces

Carton 1.500 pieces

Adjustable magnetic catch. Inserted into the door.

ø 15 mm

Packing

Box 250 pieces

Retaining catch to be inserted with pin.

ø 11.5 mm surface.

Packing

Box 250 pieces

Retaining catch with adhesive.

20x14 mm surface.

Packing

Box 250 pieces

22

Release device application

Release / Magnetic device to be inserted

Drill a hole Ø 10 mm and min. 40 mm depth in the top, the side or the bottom panel of the cabinet.

Insert the release device into the hole.

ø10

S

40 min

T

2.5

Adjustable magnetic catch

The adjustable catch DP39 is itself magnetic and together with the magnetism of the release device DPM considerably increases the holding strength (30%) of the door against the cabinet side, thus avoiding accidental opening.

For the installation it is necessary to drill a hole ø15 mm and 11 mm depth in the door.

Depth adjustment from +2.5mm / - 0.5mm

ø 10

S

40 min

2.5

ø 15

Retaining catch to be inserted

Apply the retaining catch to the magnetic release device.

Close the door.

The point of the retaining catch will show where to insert it.

Reopen the door and press the retaining catch.

T

Retaining catch with adhesive strip

Apply the retaining catch to the magnetic release device. Remove the protective strip from the adhesive. Close the and the retaining catch is positioned on the door.

Reopen the door and apply a firm pressure to the retaining catch to ensure a correct installation.

ATTENTION:

For a correct application and to ensure optimal endurance, we suggest these guidelines are followed:

1 - clean and degrease the door surface where the retaining catch is to be installed;

2 - remove the protective strip from the adhesive;

3 - place the retaining catch in position, in a place that is at room temperature ≥ 10°

(50°F) and apply a firm pressure for 10-15 seconds.

After few seconds from the installation the retaining catch is suitable for the use.

After 24h the max. hold is attained.

23

WIND

- Push application

FRAME

Where to apply the Push devices

For cabinet heights 406mm - 610mm (16” - 24”)

1 Push device

DP39 / DP28 / DP38

DPM

For cabinet heights 220mm - 406mm (8-5/8” - 16”)

2 Push devices

DP39 / DP28 / DP38

24

DPM

DPA

FRAMELESS

Where to apply the Push devices

For cabinet heights 406mm - 610mm (16” - 24”)

1 Push device

DP39 / DP28 / DP38

DPM

For cabinet heights 220mm - 406mm (8-5/8” - 16”)

2 Push devices

DP39 / DP28 / DP38

DPM

DPA

25

Notes

26

27

SALICE AMERICA INC.

2123 CROWN CENTRE DRIVE

CHARLOTTE NC. 28227

TEL. 1-800-222-9652

704 8417810

FAX 704 8417808 [email protected]

www.saliceamerica.com

SALICE CANADA INC.

4025 SLADEVIEW CRESCENT

UNIT # 7-9

MISSISSAUGA, ONTARIO L5L 5Y1

TEL. 905 8208787

FAX 905 8207226 [email protected]

www.salicecanada.com

Digital contents:

• Technical pamphlet in Pdf format

• Presentation in Pdf format

• Video

We reserve the right to change the technical specifications.

Se reserva el derecho de modificar las especificaciones técnicas.

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

advertisement