WIND
WIND
The Wind lift system is characterized by compactness and elegant design.
Its movement is smooth and perfectly controlled. Wind is small and unobtrusive, enabling the maximum utilization of cabinet internal space. Suitable for Kitchen cabinets, living room or bedroom furniture and office furniture.
In the kitchen environment, Wind has strong functional appeal - a compact adjustable lift system that takes up a minimum of valuable storage space.
Aesthetics also play a key role with Wind’s small size and streamlined shape adding significantly to the overall appeal of the cabinets to which it is installed.
Wind is available in a range of attractive finishes designed to complement the vast range of cabinet applications that it can be used for.
Wind Lift system is a simple program that covers a large variety of door sizes.
3
Wind
Technical information
Flap door lift system fixed to the cabinet sides.
Drilling of the door ø35.
13 mm deep cup.
85° opening with stop device (premounted).
94° opening without stop device.
Minimum door height 220mm / 8-5/8”
Maximum door height 610mm / 24”
Possible drilling distance on the door (K): from 3 to 7 mm.
CARATTERISTICA = 13
APERTURA MASSIMA = 94°
FORATURA SCATOLA Ø35X13
REGOLAZIONE VERTICALE = -2 +2
REGOLAZIONE FRONTALE = -1 +3
REGOLAZIONE LATERALE = -2 +2
Drilling pattern - Dimensions Frameless
Side view
33
ø5x13
Top View
ø 35
13
104
46 17.5 + K
K 3 - 7
55
177
Cabinet side
18
K = Drilling distance
D = Door overlay on the cabinet side
D
24
19
8.5
21
8.5+D
19+D
ø5x13
Space needed to open the door
A min.
D1
4
57
202
MINIMUM REVEAL TABLE
T= 16 17 18 19 20 21 22 23 24 25 26 27 28
K=3 A= 0 0.1
0.1
0.2
0.2
0.3
0.5
0.6
0.7
0.9
1.1
1.8
2.7
K=4 A=
K=5 A=
K=6 A=
0
0
0
0.1
0.1
0.1
0.1
0.1
0.1
0.2
0.2
0.2
0.2
0.2
0.2
0.3
0.3
0.3
0.4
0.4
0.4
0.6
0.6
0.6
0.7
0.7
0.7
0.9
0.9
0.9
1.1
1.1
1.0
1.3
1.3
1.2
2.1
1.5
1.5
K=7 A= 0 0.1
0.1
0.2
0.2
0.3
0.4
0.6
0.7
0.8
1.0
1.2
1.4
T
85°
OVERLAY TABLE
K
3
4
=
=
D1
16
17
5
6
7
= 18
= 19
= 20
K = Drilling distance
D1 = Door overlay on the cabinet top
A = Min Reveal
Drilling pattern - Dimensions - Frame
Side View
55
33
ø 35
200
104
174
46
55
13
K
17.5 + K
15
K = Drilling distance
D = Door overlay on the cabinet side
Top View
TH Frame recess
19
FILLER 2-3/16” x 7-7/8”
TH
D 24
8.5
8.5+D
21
19+D
Holes can be pre-drilled
5 mm dia or pilot drilled
2 mm dia.
Space needed to open the door
D1
Wind “Footprint” dimensions= 7-3/4” L x 2-1/4” H x 1-1/2” T
T
85° OVERLAY TABLE
4
5
K
3
6
7
=
=
=
=
=
D1
16
17
18
19
20
K = Drilling distance
D1 = Door overlay on the cabinet top
5
WIND -
Assembly instructions
Attaching the base to the cabinet sides
Use 5mm x 13mm system screws or #7 x 5/8” wood screws.
FRAME
Installing the cups to the door
Left Right
FRAMELESS
Left Right
FRAME
Connecting the lift mechanism to the cups
This operation is tool free.
FRAMELESS
Note:
LH lift mechanism must be installed in LH base,
RH lift mechanism must be installed in RH base.
SNAP ON
Left Right
FRAMELESS
SNAP ON
Left Right
6
FRAME
Connecting the lift system to the base
This operation is tool free.
FRAME
Installing the covers
SNAP ON
FRAMELESS
SNAP ON
FRAME FRAMELESS
7
WIND -
Adjustments
WARNING ! Security cable ties.
Remove the cable ties only at the end of the assembly.
Use the instructions and the QR Code attached to the systems.
Adjustments.
1 - adjustment of the spring strength.
2 - adjustment of the decelerating effect.
3 - removal of the angle reduction clip.
85°
85°
With stop device (premounted)
94°
94°
Without stop device
3
1
4 - height adjustment of the door from - 2 to +2.
5 - side adjustment of the door from - 2 to +2.
6 - depth adjustment of the door from - 1 to +3.
2
4
5
8
Note:
LH lift mechanism must be installed in LH base,
RH lift mechanism must be installed in RH base.
6
Disassembly instructions
Removal of the covers
FRAME FRAMELESS
Disassembly of the system
Press the back lever and remove the lift mechanism. This operation is tool free.
FRAME
Remove the lift mechanism from the cups (door)
Disconnecting the system from the cups. This operation is tool free.
FRAMELESS
FRAME FRAMELESS
9
Wind -
Optional top mount bracket
Technical information
Bracket to be attached to the top of the cabinet for use with:
• angled cabinets
• wide or heavier doors
• 5 piece doors
Note: When using the top mount bracket, the overlay is reduced by
3mm. Refer to the overlay chart below.
Drilling pattern.
Top
32 32 32 32 40
Space needed to open the door.
D1
A min.
10
5
6
7
K D1
3 = 13
4 = 14
=
=
=
15
16
17
85°
T
T=
K=3 A = min
K=4 A = min
K=5 A = min
K=6 A = min
K=7 A = min
0
0
0
16 17 18 19 20 21 22 23 24 25 26 27 28
0 0.1
0.1
0.2
0.2
0.3
0.5
0.6
0.7
0.9
1.1
1.8
2.7
0 0.1
0.1
0.2
0.2
0.3
0.4
0.6
0.7
0.9
1.1
1.3
2.1
0.1
0.1
0.1
0.1
0.1
0.1
0.2
0.2
0.2
0.2
0.2
0.2
0.3
0.3
0.3
0.4
0.4
0.4
0.6
0.6
0.6
0.7
0.7
0.7
0.9
0.9
0.8
1.1
1.0
1.0
1.3
1.2
1.2
1.5
1.5
1.4
Assembly instructions for the brackets
Attaching the brackets to the top of the cabinet.
Attach with five #8 x 5/8” wood screws provided
Attaching the base to the top bracket.
Attach with the 3 machine screws provided.
Connecting the lift system to the base.
This operation is tool free.
Installing the covers.
11
Wind -
Disassembly instructions for the top mount brackets
Removal of the covers.
Disassembly of the system.
Press the back lever and remove the lift system.
This operation is tool free.
Remove the base from the bracket.
Remove the screws and the bracket.
12
Top mount bracket applications
For cabinets that require a third system. For wide cabinet applications without a center partition.
The maximum door width for two Wind is 1200mm/48”
Note: Wind can be used on doors that are larger or heavier by adding additional Wind lifts to the cabinet and door.
This can be done by installing a center partition and adding additional Wind lifts or by utilizing the Top Mount Brackets with additional Wind lifts.
For all applications requiring more than two Wind lifts, check the Wind charts on pages 19 & 20.
Please consult with your local sales representative or contact technical service.
5
6
7
K
3
4
D1
= 13
= 14
= 15
= 16
= 17
For angled cabinets.
3
3
The bracket has a thickness of 3 mm and the cabinet side drilling must be lowered by 3mm. The Wind covers are adjustable and can be positioned to cover the 3mm space at the top.
49
36
36
18 55
49
104
18 55 104
K
5
6
3
4
7
D1
= 13
= 14
= 15
= 16
= 17
13
SRXA78AMSNXX_
Gray
Nickel-plated cover cap
SRXA78A0SNXX_
Satin metal black
Titanium cover cap
SRXA78ACSNXX_
Champagne
Nickel-plated cover cap
14
Wind -
Cover finishes for the cabinet base
SRXA78A1SNXX_
White
Nickel-plated cover cap
SRXA78AQSNXX_
Glossy white
Nickel-plated cover cap
SRXA78AISNXX_
Stainless steel
Nickel-plated cover cap
SRXA78ANSNXX_
Glossy metal black
Titanium cover cap
Cover finishes for the Top mount bracket
SRUA78A1SNXXI
White
SRUA78AQSNXXI
Glossy white
SRUA78AMSNXXI
Gray
SRUA78AISNXXI
Stainless steel
SRUA78ANSNXXI
Glossy metal black
SRUA78A0SNXXI
Satin metal black
SRUA78ACSNXXI
Champagne
15
WIND
- Packaging
KIT PACKAGING
PUSH
INDUSTRIAL PACKAGING
PART NUMBER
SOFT CLOSE
FRAKFEX_SN9
SPRING FORCE
See page 18 and 19 for the appropriate spring package letter
PUSH OPENING
FRAKFEP_SN9
SPRING FORCE
See page 18 and 19 for the appropriate spring package letter
PART NUMBER
PACKAGING
One box contains:
2 hinge cups
•
1 Right hand lift mechanism
1 Left hand lift mechanism
•
1 Right hand cabinet base
1 Left hand cabinet base
•
Includes 5mm x 13mm system screws
Note : #7 x 5/8” wood screws can also be used
PACKAGING
SOFT CLOSE
FRAKINX_SN9
SPRING FORCE
PUSH OPENING
FRAKINP_SN9
SPRING FORCE
One box contains:
18 Hinge cups
•
9 Right hand lift mechanisms
9 Left hand lift mechanisms
•
9 Right hand cabinet bases
9 Left hand cabinet bases
•
Includes 5mm x 13mm system screws
Note : #7 x 5/8” wood screws can also be used
PUSH
COVERS PART NUMBER
KIT PACKAGING
SRXA78A_SNXXF
COVER COLOR
See page 14 for the appropriate cover number
INDUSTRIAL PACKAGING
SRXA78A_SNXXI
COVER COLOR
See page 14 for the appropriate cover number
PACKAGING
One box contains:
1 Right hand cover
1 Left hand cover
Includes cover caps
Note: can be personalized
One box contains:
9 Right hand covers
9 Left hand covers
Includes cover caps
Note: can be personalized
16
KIT-SET PACKING
BRACKET AND COVER
PART NUMBER PACKAGING
FRAUFEXXXX_
COLOR OF
THE COVER
1 carton contains:
2 brackets
•
2 covers for the brackets
•
Wood screws to install the bracket and machine screws to attach the base are included.
INDUSTRIAL PACKAGING
TOP MOUNT BRACKET
PART NUMBER PACKAGING
FRAUINXXXX5
1 carton contains:
18 brackets
•
Wood screws to install the bracket and machine screws to attach the base are included.
INDUSTRIAL PACKAGING
COVER FOR THE BRACKET
PART NUMBER PACKAGING
SRUA78A_SNXXI
COLOR OF
THE COVER
1 carton contains:
18 covers for the brackets
17
8
7
0.8
0.6
0.4
0.2
0.6
0.4
0.2
6
0.8
0.6
0.4
0.2
5
0.8
0.6
0.4
0.2
4
0.8
0.6
0.4
0.2
3
0.8
0.4
0.6
Wind
2
-
Charts and
Spring force identification
0.8
0.2
0.6
0.4
0.2
1
FRAK
03
XXSN_ include the weight of the decorative hardware. The maximum door width for two Wind lifts is 1200mm/48”.
Note: Wind can be used on doors that are larger or heavier by adding additional Wind lifts to the cabinet and door. This can be done by installing a center partition and adding additional Wind lifts or by utilizing the Top Mount Brackets with additional Wind lifts.
For all applications requiring more than two Wind lifts, check the Wind charts on pages 19 & 20. Please consult with your local sales representative or contact technical service.
6
0.8
0.6
0.4
0.2
5
0.8
0.4
0.6
0.2
4
0.8
0.6
0.4
0.2
3
0.8
0.4
0.6
0.2
2
1
0.8
0.6
0.4
0.2
220 280 320 360 400 440
Door height (mm)
480 520
Min door height - 8-5/8”
Max door height - 15-3/4”
FRAK
03
XXSN_
18
8
0.8
0.6
0.4
0.2
7
0.6
0.4
0.2
6
0.8
0.6
0.4
0.2
5
0.8
0.6
0.4
0.2
4
0.8
0.6
0.4
0.2
3
0.8
0.6
0.4
2
0.8
0.2
0.6
0.4
0.2
1
220 280 320 360 400 440 480
Door height (mm)
520 560 600
Min door height - 8-5/8”
Max door height - 24”
Door height (mm)
15
0.8
0.6
0.4
0.2
14
0.8
0.6
0.4
0.2
13
0.8
0.6
0.4
0.2
12
0.8
0.6
0.4
0.2
11
0.8
0.6
0.4
0.2
10
0.8
0.4
0.6
0.2
9
0.8
0.6
0.4
0.2
8
0.8
0.4
0.6
0.2
7
0.8
0.6
0.4
0.2
6
0.8
0.6
0.4
0.2
5
0.8
0.6
0.4
0.2
4
0.8
0.6
0.4
0.2
3
0.8
0.6
0.4
0.2
2
320 360 400 440 480 520 560 600
Door height (mm)
Min door height - 12-9/16”
Max door height - 24”
4 WIND
3 WIND
2 WIND
FRAK
N
XXSN_
20
0.8
0.6
0.4
19
0.2
0.8
0.6
0.4
0.2
18
0.8
0.6
0.4
0.2
17
0.8
0.6
0.4
0.2
16
0.8
0.6
0.4
0.2
15
0.8
0.6
0.4
0.2
14
0.8
0.6
0.4
0.2
13
0.8
0.6
0.4
0.2
12
0.8
0.6
0.4
0.2
11
0.8
0.6
0.4
0.2
10
0.8
0.6
0.4
0.2
9
0.8
0.6
0.4
0.2
8
0.8
0.6
0.4
0.2
7
0.8
0.6
0.4
0.2
6
0.8
0.6
0.4
0.2
5
0.8
0.6
0.4
4
4 WIND
3 WIND
2 WIND
320 360 400 440 480 520 560 600
Min door height - 12-9/16”
Max door height - 24”
FRAK
F
XXSN_
19
Wind
-
Charts and
Spring force identification
24
0.8
0.4
0.2
23
0.8
0.6
0.4
0.2
22
0.8
0.6
0.4
0.2
21
0.8
0.6
0.4
20
0.8
0.2
0.6
0.4
0.2
19
0.8
0.6
0.4
0.2
18
0.8
0.6
0.4
0.2
17
0.8
0.6
0.4
0.2
16
0.8
0.6
0.4
0.2
15
0.8
0.6
0.4
0.2
14
0.8
0.6
0.4
0.6
0.2
13
0.8
0.6
0.4
0.2
12
0.8
0.6
0.4
0.2
11
0.8
0.6
0.4
0.2
10
0.8
0.6
0.4
0.2
9
0.8
0.6
0.4
0.2
8
0.8
0.6
0.4
0.2
7
0.8
0.6
0.4
0.2
6
320 360 400 440 480 520 560
Door height (mm)
600
Min door height - 12-9/16”
Max door height - 24”
4 WIND
3 WIND
2 WIND
FRAK
S
XXSN_
20
Magnetic Push
21
Magnetic Push
- Release device and retaining catches
DPMSNB
- beige
DPMSNG
- gray
Release device.
ø 10 mm, 40 mm length.
DPASNB
- beige
DP39XXG
DP28SN9
DP38XX91
DPASNG
- gray
Packing
Box 250 pieces
Carton 1.500 pieces
Magnetic device to be used to increase the magnetic holding strength. It must always be used together with the DPM. The suggested position of the DPM is the point of pressure on the door. The DPA can be positioned at any point along the opening edge of the door.
ø 10 mm, 40 mm length.
Packing
Box 250 pieces
Carton 1.500 pieces
Adjustable magnetic catch. Inserted into the door.
ø 15 mm
Packing
Box 250 pieces
Retaining catch to be inserted with pin.
ø 11.5 mm surface.
Packing
Box 250 pieces
Retaining catch with adhesive.
20x14 mm surface.
Packing
Box 250 pieces
22
Release device application
Release / Magnetic device to be inserted
Drill a hole Ø 10 mm and min. 40 mm depth in the top, the side or the bottom panel of the cabinet.
Insert the release device into the hole.
ø10
S
40 min
T
2.5
Adjustable magnetic catch
The adjustable catch DP39 is itself magnetic and together with the magnetism of the release device DPM considerably increases the holding strength (30%) of the door against the cabinet side, thus avoiding accidental opening.
For the installation it is necessary to drill a hole ø15 mm and 11 mm depth in the door.
Depth adjustment from +2.5mm / - 0.5mm
ø 10
S
40 min
2.5
ø 15
Retaining catch to be inserted
Apply the retaining catch to the magnetic release device.
Close the door.
The point of the retaining catch will show where to insert it.
Reopen the door and press the retaining catch.
T
Retaining catch with adhesive strip
Apply the retaining catch to the magnetic release device. Remove the protective strip from the adhesive. Close the and the retaining catch is positioned on the door.
Reopen the door and apply a firm pressure to the retaining catch to ensure a correct installation.
ATTENTION:
For a correct application and to ensure optimal endurance, we suggest these guidelines are followed:
1 - clean and degrease the door surface where the retaining catch is to be installed;
2 - remove the protective strip from the adhesive;
3 - place the retaining catch in position, in a place that is at room temperature ≥ 10°
(50°F) and apply a firm pressure for 10-15 seconds.
After few seconds from the installation the retaining catch is suitable for the use.
After 24h the max. hold is attained.
23
WIND
- Push application
FRAME
Where to apply the Push devices
For cabinet heights 406mm - 610mm (16” - 24”)
1 Push device
DP39 / DP28 / DP38
DPM
For cabinet heights 220mm - 406mm (8-5/8” - 16”)
2 Push devices
DP39 / DP28 / DP38
24
DPM
DPA
FRAMELESS
Where to apply the Push devices
For cabinet heights 406mm - 610mm (16” - 24”)
1 Push device
DP39 / DP28 / DP38
DPM
For cabinet heights 220mm - 406mm (8-5/8” - 16”)
2 Push devices
DP39 / DP28 / DP38
DPM
DPA
25
Notes
26
27
SALICE AMERICA INC.
2123 CROWN CENTRE DRIVE
CHARLOTTE NC. 28227
TEL. 1-800-222-9652
704 8417810
FAX 704 8417808 [email protected]
www.saliceamerica.com
SALICE CANADA INC.
4025 SLADEVIEW CRESCENT
UNIT # 7-9
MISSISSAUGA, ONTARIO L5L 5Y1
TEL. 905 8208787
FAX 905 8207226 [email protected]
www.salicecanada.com
Digital contents:
• Technical pamphlet in Pdf format
• Presentation in Pdf format
• Video
We reserve the right to change the technical specifications.
Se reserva el derecho de modificar las especificaciones técnicas.
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement