BVD-405A-2, BVD-405A-4, BVD-405CP-2, BVD-405CP-4

OPERATING INSTRUCTION

Doorstation BVD 5 is intended for operation within VIZIT doorphones / video doorphones (Series Comfort).

The following models are available :

BVD 5 doorstation to connect 2 apartment handsets UKP ;

-

-

BVD 5 -

BVD 5 P doorstation to connect 4 apartment handsets

-

UKP ; video doorstation with colour camera to connect 2 video monitors;

BVD 5 P video doorstation with colour camera to connect 4 video monitors .

Abbreviations used in the model names :

A

С

-

-

No camera ;

Colour camera

P - Pinhole lens.

;

BVD -40 5CP4,

BVD 5 -

BVD -40 5CP2,

BVD 5 -

1

2

3

4

9

8

7

6

5

1 Colour camera

( BVD -40 5CP-2(4))

2 IR LEDs

( illumination for camera in

BVD -40 5CP-2(4))

3 Niche for name plate

4 Speaker

5 CALL button for Apartment 4

6 CALL button for Apartment 3

7 CALL button for Apartment 2

8 CALL button for Apartment 1

9 Microphone

Figure 1 Doorstation BVD-405x

FEATURES

Individual CALL button for subscribers

Beep in the doorstation and monitor / apartment handsets, when the CALL button is pressed.

Duplex intercom

Door zone video monitoring ( BVD-405CP-2

Remote door unlocking by pressing the

Beeps to indicate door lock release and BVD-405CP-4 ) button on the monitor / apartment handset during intercom

IR illumination for the camera ( BVD-405CP-2

Lighting for the name plate and BVD-405CP-4 )

-

Subscriber devices are apartment handsets

VIZIT®

UKP ;

video monitors VIZIT-М of Series trademarked products:

400.

SAFETY INSTRUCTIONS

The product does not contain voltage above 25 V .

Do not make any connections or repair, when the power is on.

Take care not to spill any liquids or chemically active substances on the product. Switch the power off before cleaning the product. Clean by wiping with dry soft cloth. Do not use any liquid cleaners, aerosol cleaners or abrasive agents.

www.

vizit-group.com

BVD-405A-2, BVD-405A-4, BVD-405CP-2, BVD-405CP-4 Operating Instruction (revision 12) 1/ 10

PARTS LIST x 1 x 1

Doorstation BVD 5 Skew Base x 1 x 1

Operating Instruction Blank nameplate

Fasteners for doorstation BVD 5 and skew base x 2

Screw М4х1 6 x 4

Gag x 2

Screw - 4х40 x 2

Anchor 6x40

INSTALLATION ORDER

For qualified installation, wiring and servicing refer to technical and commercial partners of VIZIT TM.

The list of companies is given on VIZIT.EU ( http://vizit.eu/eurounion/) .

The doorstation is mounted on a wall near your entrance door. The skew base provides 20° turn, and allows either leftside or right-side mounting .

To protect the doorstation against the sun, rain or snow, installation of specially designed

Mounting Kit MK-405 is recommended. Installation order of the doorstation together with its sun/rain shield is described in the Mounting Kit MK-405 installation manual.

2

3

5

4

7

6

1

2

3

1

Doorstation

Skew base

Screw 6 х2 )

4

5

6

7

Hole

6

( х2 ) mm in diameter

40 mm deep

Anchor ( х2 )

Screw - 4х40 ( х2 )

Gag ( х2 )

Fasteners are supplied.

www.

vizit-group.com

BVD-405A-2, BVD-405A-4, BVD-405CP-2, BVD-405CP-4 Operating Instruction (revision 12)

FD

FC

LC

GND

FB

FA

VO

FA

FB

FC

-

-

-

Intercom l ine "-" to Apartment

Intercom l ine "-" to Apartment

Intercom l ine "-" to Apartment

1

2

3

FD

VO

-

-

Intercom l ine "-" to Apartment

( 40

4

5CP-2, BVD-405CP-4 )

L N -

LC Lock control (MOSFET open drain)

4

GND

+Е -

Ground

Supply voltage for Doorstation www.

vizit-group.com

BVD-405A-2, BVD-405A-4, BVD-405CP-2, BVD-405CP-4 Operating Instruction (revision 12)

Locate the doorstation so as to avoid :

direct rays of the sun or other sources of light ;

- direct hit of rain or snow .

50 cm

34° 34°

80 cm 80 cm and camera field of view

Wiring diagrams for doorphone / video doorphone are shown in the section EXAMPLES OF WIRING DIAGRAMS .

Use copper wires for connections in accordance with the recommended lengths and cross-sections given in the section

EXAMPLES OF WIRING DIAGRAMS .

To reduce possibility of external noises influencing image, use 75-Ohm coaxial cable for video circuits.

NOTE.

The doorstation is supplied wit a blank name plate. The name plate is a two-layer plastic plate with black base and silver top layer. It is intended to have inscriptions on it, such as dwellers’ names, apartment or office numbers, company names etc. Inscriptions are made by laser engraving, with removing silver layer and revealing the black base. Please refer to a specialist to have the inscriptions made. Pattern and dimensions for laser engraving are shown on Figure 6.

30.5

30.5

Figure 6 Pattern and dimensions for laser engraving on the nameplate

The name plate is fixed in the niche in the doorstation’s front panel. To ensure proper fixing, clean the surface of the niche with alcohol, then remove the protective film from the adhesive tape on the name plate’s back, and firmly attach the name plate in the niche.

www.

vizit-group.com

BVD-405A-2, BVD-405A-4, BVD-405CP-2, BVD-405CP-4 Operating Instruction (revision 12)

EXAMPLES OF WIRING DIAGRAMS

Power Supply Unit

BPD18/12-1-1

Electromechanical lock / strike

12V / 0.6A max.

1N4007

+E

GND

Circuits

Circuit length m

25 50

BPD 1 BVD

BVD-405А-2 UKP

BPD 1 Lock

-405А-2

Note . If an electromechanical lock / strike has no built-in damper diode, the diode shall be set additionally between terminals of the lock /strike as shown in the diagram.

Apt. 1 Apt. 2

UKP UKP

0.25

0.5

0.5

1.0

Min. wire crosssection, mm 2

Doorstation

BVD -40 5A-2

FD

FC

LINE

LC

GND

+E

FB

FA

VO

GND

+E

LN

FB

FA

LN

-

FA LN

-

FB

Power Supply Unit

BPD 1

+18

-18

-12

+12

Electromechanical lock / strike

12V / 0.6A max.

+E

GND

Doorstation

BVD -40 5A-4

FD

FC

LINE

LC

GND

+E

FB

FA

VO

1N4007

GND

+E

Circuits

Circuit length m

25 50

BPD 1 BVD -405А4

BVD -405А4 UKP

BPD 1 Lock

0.25

0.5

0.5

1.0

Min. wire crosssection, mm 2

Note . If an electromechanical lock / strike has no built-in damper diode, the diode shall be set additionally between terminals of the lock /strike as shown in the diagram.

Apt. 1 Apt. 2 Apt. 3 Apt. 4

UKP UKP UKP UKP

FD

FC

LN

FB

FA

LN

-

FA LN

-

FB LN

-

FC LN

-

FD

Figure 8 - 4-apartment doorphone www.

vizit-group.com

BVD-405A-2, BVD-405A-4, BVD-405CP-2, BVD-405CP-4 Operating Instruction (revision 12)

Electromagnetic lock

VIZIT-ML240-40

-DL

+DL

Green

Blue

White

Black

Red

Button

EXIT 300 М

Red

Black

Blue

White

Reader

RD-3 (RD-4F)

+E

GND

BIP

RD

GND

LC

LC GND

LC GND

+E

+E

+E

BIP

RD

GND

LC

-DL

+DL

Control

Unit

KТМ602М

-DL

+DL

ELC

BIP

RD

GND

OP

Doorstation

BVD -40 5A4

FD

FC

LINE

LC

GND

+E

FB

FA

VO

LC

GND

+E

FD

FC

LN

FB

FA

Apt. 1 Apt. 2 Apt. 3 Apt. 4

UKP UKP UKP UKP

-

LN FA LN FB LN FC LN FD

Circuits

KTM602M BVD -405А-4

BVD-405А-4 UKP

KTM602M VIZIT-ML400

Figure 9 4-apartment doorphone with RF Controller

Circuit length, m

25 50

0.25

0.5

Min. wire crosssection, mm 2

( 2 ) www.

vizit-group.com

BVD-405A-2, BVD-405A-4, BVD-405CP-2, BVD-405CP-4 Operating Instruction (revision 12)

* - video monitors that may be used in this diagram:

VIZIT-M4 27C

VIZIT-M4 40C

VIZIT-M4 40CM

VIZIT-M4 41M

VIZIT-M4 41M

VIZIT-M4

VIZIT-M4

VIZIT-M4

56C

56CM

57M

Power Supply Unit

BPD 1

+18

-18

-12

+12

Electromechanical lock / strike

12V / 0.6A max.

+E

GND

1N4007

GD

VGD

VOD

+ED

GD

VGD

VOD

+ED

FD

LN

+ED

VOD

VGD

GD

+E

VI1

GND

LN-

LN+

Apt. 4

FD

FC

LINE

LC

GND

+E

FB

FA

VO

Doorstation

BVD -40 5A-4

FD

FC

LN

FB

FA

GND

+E

Circuits

BPD24/12-1-1 RVE 4 Monitors

BPD BVD A

BPD24/12-1-1 Outdoor Camera

Outdoor Camera

BVD A Monitors

Monitors

BPD Lock

Circuit length, m

25

0.5

0.25

50

1.0

0.5

0.5

1.0

Min. wire crosssection, mm 2

Figure 10 - 4-apartment video doorphone with outdoor camera and video monitors VIZIT* powered from a group power supply unit

Monitor

VIZIT*

GC

VGC

VOC

+EC

GC

VGC

VOC

+EC

FC

LN

+EC

VOC

VGC

GC

+E

VI1

GND

LN-

LN+

Apt. 3

Distribution Amplifier

RVE-4

Jumper shall be

Z set up

GB

VGB

VOB

+EB

GB

VGB

VOB

+EB

FB

LN

+EB

VOB

VGB

GB

+E

VI1

GND

LN-

LN+

Apt. 2

GA

VGA

VOA

+EA

GA

VGA

VOA

+EA

Power Supply Unit

BPD24 /12- -1

+24V

GND

GND

+12V

+24V

GND

GND

+12V

VI

VG

GND

+12V

FA

LN

+EA

VOA

VGA

GA

+E

VI1

GND

LN-

LN+

Apt. 1 green black red

Monitor

VIZIT*

Monitor

VIZIT*

Monitor

VIZIT*

Outdoor Camera

VIZIT-C70 www.

vizit-group.com

BVD-405A-2, BVD-405A-4, BVD-405CP-2, BVD-405CP-4 Operating Instruction (revision 12)

* - video monitors that may be used in this diagram:

VIZIT-M4 27C

VIZIT-M4 40C

VIZIT-M4 40CM

VIZIT-M4 41M

VIZIT-M4 41M

VIZIT-M4 56C

VIZIT-M4 56CM

VIZIT-M4 57M

GD

VGD

VOD

+ED

GC

VGC

VOC

+EC

GD

VGD

VOD

+ED

GC

VGC

VOC

+EC

FD

LN

+ED

VOD

VGD

GD

FC

LN

+EC

VOC

VGC

GC

+E

VI1

GND

LN-

LN+

Apt. 4

+E

VI1

GND

LN-

LN+

Apt. 3

Distribution Amplifier

RVE-4

Power Supply Unit

BPD 1

+18

-18

-12

+12

Electromechanical lock / strike

12V / 0.6A max.

+E

GND

Jumper shall be

Z set up

GB

VGB

VOB

+EB

GB

VGB

VOB

+EB

FB

LN

+EB

VOB

VGB

GB

+E

VI1

GND

LN-

LN+

Apt. 2

1N4007

GA

VGA

VOA

+EA

GA

VGA

VOA

+EA

FA

LN

+EA

VOA

VGA

GA

+E

VI1

GND

LN-

LN+

Apt. 1

FD

FC

LINE

LC

GND

+E

FB

FA

VO

Doorstation

BVD -40 5CP-4

FD

FC

LN

GND

+E

FB

FA

VI

VG

Power Supply Unit

BPD24 /12- -1

+24V

GND

GND

+12V

+24V

GND

Circuits

BPD24/12-1-1 RVE 4 Monitors

BPD 1 BVD -405 CP -4

BVD -405 CP -4

BVD -405 CP -4 Monitors

BPD 1 Lock

Circuit length, m

25

0.5

0.25

50

1.0

0.5

0.5

1.0

Min. wire crosssection, mm 2

Figure 11 - 4-apartment video doorphone with video monitors powered from a group power supply unit

VIZIT*

Monitor

VIZIT*

Monitor

VIZIT*

Monitor

VIZIT*

Monitor

VIZIT* www.

vizit-group.com

BVD-405A-2, BVD-405A-4, BVD-405CP-2, BVD-405CP-4 Operating Instruction (revision 12)

* - video monitors that may be used in this diagram:

VIZIT-M4 27C

VIZIT-M4 40C

VIZIT-M4 40CM

VIZIT-M4 41M

VIZIT-M4 41M

VIZIT-M4 56C

VIZIT-M4 56CM

VIZIT-M4 57M

GD

VGD

VOD

+ED

Power Supply Unit

BPD 1

+18

-18

-12

+12

Electromechanical lock / strike

12V / 0.6A max.

+E

GND

1N4007

GC

VGC

VOC

+EC

Distribution Amplifier

RVE-4

GB

VGB

VOB

+EB

GB

VGB

VOB

+EB

Jumper shall be

Z set up

GA

VGA

VOA

+EA

GA

VGA

VOA

+EA

FD

FC

LINE

LC

GND

+E

FB

FA

VO

Doorstation

BVD -40 5CP-2

LN

GND

+E

FB

FA

VI

VG

Power Supply Unit

BPD24 /12- -1

+24V

GND

GND

+12V

+24V

GND

Circuits

BPD24/12-1-1 RVE 4 Monitors

BPD 1 BVD -405 -

BVD -405 CP 2

BVD -405 CP 2

BPD 1

Monitors

Lock

Circuit length, m

25

0.5

0.25

50

1.0

0.5

0.5

1.0

Min. wire crosssection, mm 2

Figure 12 - 2-apartment video doorphone

FB

LN

+EB

VOB

VGB

GB

+E

VI1

GND

LN-

LN+

Apt. 2

FA

LN

+EA

VOA

VGA

GA

+E

VI1

GND

LN-

LN+

Apt. 1

Monitor

VIZIT*

Monitor

VIZIT* www.

vizit-group.com

BVD-405A-2, BVD-405A-4, BVD-405CP-2, BVD-405CP-4 Operating Instruction (revision 12)

FUNCTIONAL CHECK AND OPERATING ORDER

Before switching the power on, verify all electric connections.

• Turn the power supply unit(s) on.

• To make a call to the subscriber, press one of the CALL buttons on the doorstation. A call sound is ringing both in the corresponding monitor (apartment handset) and doorstation, while the CALL button remains pressed. Image appears on the monitor’s screen.

Pick up the handset and check duplex intercom.

Check image on the monitor’s screen. Adjust image brightness, contrast and saturation, if needed.

Press the on the monitor (apartment handset) to release the door lock. The doorstation produces a beep, and the lock stays released while the button remains pressed. Release the button to return to the intercom mode.

Note.

When called, the subscriber can press the button to release the door lock without picking up the handset.

The system goes to the stand-by mode after the button is released.

Intercom is available within (60 ± 5) seconds after picking up the handset.

If the handset is not picked up in 60 seconds, the system returns to the stand-by mode automatically .

• One by one check the rest of connected apartment handsets / monitors for intercom, video (for monitors), remote door unlocking function.

SPECIFICATIONS

Operating voltage:

Power consumption:

Dimensions (W)x(H)x(D):

Weight:

Weight with package :

16...25

3

0

VDC

W max.

.3 kg

The built-in camera parameters (BVD40 5CP-x) are given below:

Lens

Angle of view (diagonal)

Scanning system

Colour system

Resolution

Camera Parameters

Pinhole

90 °

СCIR

PAL

700 TVL

0 Lux (IR LED on

Minimal illumination

Day-Night feature

Output voltage

. Lux IR LED off )

YES

1 Vp-p at 75 О hm

OPERATING CONDITIONS

Ambient temperature range :

-

-

BVD

BVD

-40 А

-40 5CP-2(4)

Relative humidity of air:

40°C

- 3 0°C up to to to

+

+

45°C

45°C

98% at 25°C www.

vizit-group.com

BVD-405A-2, BVD-405A-4, BVD-405CP-2, BVD-405CP-4 Operating Instruction (revision 12)

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

advertisement