ViziT BVD-405A-2, BVD-405CP-2 Operating Instructions Manual
Add to my manuals
10 Pages
ViziT BVD-405A-2 is a door station designed to operate with VIZIT doorphones and video doorphones of Comfort Series and to connect up to 2 apartment handsets UKP. It features an intercom system with duplex communication and subscriber devices, individual CALL button for each subscriber, beep in the door station and monitor/apartment handset when the CALL button is pressed, remote door unlocking, and illumination for the name plate.
advertisement
BVD-405A-2, BVD-405A-4, BVD-405CP-2, BVD-405CP-4
OPERATING INSTRUCTION
Doorstation BVD 5 is intended for operation within VIZIT doorphones / video doorphones (Series Comfort).
The following models are available :
BVD 5 doorstation to connect 2 apartment handsets UKP ;
-
-
BVD 5 -
BVD 5 P doorstation to connect 4 apartment handsets
-
UKP ; video doorstation with colour camera to connect 2 video monitors;
BVD 5 P video doorstation with colour camera to connect 4 video monitors .
Abbreviations used in the model names :
A
С
-
-
No camera ;
Colour camera
P - Pinhole lens.
;
BVD -40 5CP4,
BVD 5 -
BVD -40 5CP2,
BVD 5 -
1
2
3
4
9
8
7
6
5
1 Colour camera
( BVD -40 5CP-2(4))
2 IR LEDs
( illumination for camera in
BVD -40 5CP-2(4))
3 Niche for name plate
4 Speaker
5 CALL button for Apartment 4
6 CALL button for Apartment 3
7 CALL button for Apartment 2
8 CALL button for Apartment 1
9 Microphone
Figure 1 Doorstation BVD-405x
FEATURES
Individual CALL button for subscribers
Beep in the doorstation and monitor / apartment handsets, when the CALL button is pressed.
Duplex intercom
Door zone video monitoring ( BVD-405CP-2
Remote door unlocking by pressing the
Beeps to indicate door lock release and BVD-405CP-4 ) button on the monitor / apartment handset during intercom
IR illumination for the camera ( BVD-405CP-2
Lighting for the name plate and BVD-405CP-4 )
-
Subscriber devices are apartment handsets
VIZIT®
UKP ;
video monitors VIZIT-М of Series trademarked products:
400.
SAFETY INSTRUCTIONS
The product does not contain voltage above 25 V .
Do not make any connections or repair, when the power is on.
Take care not to spill any liquids or chemically active substances on the product. Switch the power off before cleaning the product. Clean by wiping with dry soft cloth. Do not use any liquid cleaners, aerosol cleaners or abrasive agents.
www.
vizit-group.com
BVD-405A-2, BVD-405A-4, BVD-405CP-2, BVD-405CP-4 Operating Instruction (revision 12) 1/ 10
PARTS LIST x 1 x 1
Doorstation BVD 5 Skew Base x 1 x 1
Operating Instruction Blank nameplate
Fasteners for doorstation BVD 5 and skew base x 2
Screw М4х1 6 x 4
Gag x 2
Screw - 4х40 x 2
Anchor 6x40
INSTALLATION ORDER
For qualified installation, wiring and servicing refer to technical and commercial partners of VIZIT TM.
The list of companies is given on VIZIT.EU ( http://vizit.eu/eurounion/) .
The doorstation is mounted on a wall near your entrance door. The skew base provides 20° turn, and allows either leftside or right-side mounting .
To protect the doorstation against the sun, rain or snow, installation of specially designed
Mounting Kit MK-405 is recommended. Installation order of the doorstation together with its sun/rain shield is described in the Mounting Kit MK-405 installation manual.
2
3
5
4
7
6
1
2
3
1
Doorstation
Skew base
Screw 6 х2 )
4
5
6
7
Hole
6
( х2 ) mm in diameter
40 mm deep
Anchor ( х2 )
Screw - 4х40 ( х2 )
Gag ( х2 )
Fasteners are supplied.
www.
vizit-group.com
BVD-405A-2, BVD-405A-4, BVD-405CP-2, BVD-405CP-4 Operating Instruction (revision 12)
FD
FC
LC
GND
+Е
FB
FA
VO
FA
FB
FC
-
-
-
Intercom l ine "-" to Apartment
Intercom l ine "-" to Apartment
Intercom l ine "-" to Apartment
1
2
3
FD
VO
-
-
Intercom l ine "-" to Apartment
( 40
4
5CP-2, BVD-405CP-4 )
L N -
LC Lock control (MOSFET open drain)
4
GND
+Е -
Ground
Supply voltage for Doorstation www.
vizit-group.com
BVD-405A-2, BVD-405A-4, BVD-405CP-2, BVD-405CP-4 Operating Instruction (revision 12)
Locate the doorstation so as to avoid :
direct rays of the sun or other sources of light ;
- direct hit of rain or snow .
50 cm
34° 34°
80 cm 80 cm and camera field of view
Wiring diagrams for doorphone / video doorphone are shown in the section EXAMPLES OF WIRING DIAGRAMS .
Use copper wires for connections in accordance with the recommended lengths and cross-sections given in the section
EXAMPLES OF WIRING DIAGRAMS .
To reduce possibility of external noises influencing image, use 75-Ohm coaxial cable for video circuits.
NOTE.
The doorstation is supplied wit a blank name plate. The name plate is a two-layer plastic plate with black base and silver top layer. It is intended to have inscriptions on it, such as dwellers’ names, apartment or office numbers, company names etc. Inscriptions are made by laser engraving, with removing silver layer and revealing the black base. Please refer to a specialist to have the inscriptions made. Pattern and dimensions for laser engraving are shown on Figure 6.
30.5
30.5
Figure 6 Pattern and dimensions for laser engraving on the nameplate
The name plate is fixed in the niche in the doorstation’s front panel. To ensure proper fixing, clean the surface of the niche with alcohol, then remove the protective film from the adhesive tape on the name plate’s back, and firmly attach the name plate in the niche.
www.
vizit-group.com
BVD-405A-2, BVD-405A-4, BVD-405CP-2, BVD-405CP-4 Operating Instruction (revision 12)
EXAMPLES OF WIRING DIAGRAMS
Power Supply Unit
BPD18/12-1-1
Electromechanical lock / strike
12V / 0.6A max.
1N4007
+E
GND
Circuits
Circuit length m
25 50
BPD 1 BVD
BVD-405А-2 UKP
BPD 1 Lock
-405А-2
Note . If an electromechanical lock / strike has no built-in damper diode, the diode shall be set additionally between terminals of the lock /strike as shown in the diagram.
Apt. 1 Apt. 2
UKP UKP
0.25
0.5
0.5
1.0
Min. wire crosssection, mm 2
Doorstation
BVD -40 5A-2
FD
FC
LINE
LC
GND
+E
FB
FA
VO
GND
+E
LN
FB
FA
LN
-
FA LN
-
FB
Power Supply Unit
BPD 1
+18
-18
-12
+12
Electromechanical lock / strike
12V / 0.6A max.
+E
GND
Doorstation
BVD -40 5A-4
FD
FC
LINE
LC
GND
+E
FB
FA
VO
1N4007
GND
+E
Circuits
Circuit length m
25 50
BPD 1 BVD -405А4
BVD -405А4 UKP
BPD 1 Lock
0.25
0.5
0.5
1.0
Min. wire crosssection, mm 2
Note . If an electromechanical lock / strike has no built-in damper diode, the diode shall be set additionally between terminals of the lock /strike as shown in the diagram.
Apt. 1 Apt. 2 Apt. 3 Apt. 4
UKP UKP UKP UKP
FD
FC
LN
FB
FA
LN
-
FA LN
-
FB LN
-
FC LN
-
FD
Figure 8 - 4-apartment doorphone www.
vizit-group.com
BVD-405A-2, BVD-405A-4, BVD-405CP-2, BVD-405CP-4 Operating Instruction (revision 12)
Electromagnetic lock
VIZIT-ML240-40
-DL
+DL
Green
Blue
White
Black
Red
Button
EXIT 300 М
Red
Black
Blue
White
Reader
RD-3 (RD-4F)
+E
GND
BIP
RD
GND
LC
LC GND
LC GND
+E
+E
+E
BIP
RD
GND
LC
-DL
+DL
Control
Unit
KТМ602М
-DL
+DL
ELC
BIP
RD
GND
OP
Doorstation
BVD -40 5A4
FD
FC
LINE
LC
GND
+E
FB
FA
VO
LC
GND
+E
FD
FC
LN
FB
FA
Apt. 1 Apt. 2 Apt. 3 Apt. 4
UKP UKP UKP UKP
-
LN FA LN FB LN FC LN FD
Circuits
KTM602M BVD -405А-4
BVD-405А-4 UKP
KTM602M VIZIT-ML400
Figure 9 4-apartment doorphone with RF Controller
Circuit length, m
25 50
0.25
0.5
Min. wire crosssection, mm 2
( 2 ) www.
vizit-group.com
BVD-405A-2, BVD-405A-4, BVD-405CP-2, BVD-405CP-4 Operating Instruction (revision 12)
* - video monitors that may be used in this diagram:
VIZIT-M4 27C
VIZIT-M4 40C
VIZIT-M4 40CM
VIZIT-M4 41M
VIZIT-M4 41M
VIZIT-M4
VIZIT-M4
VIZIT-M4
56C
56CM
57M
Power Supply Unit
BPD 1
+18
-18
-12
+12
Electromechanical lock / strike
12V / 0.6A max.
+E
GND
1N4007
GD
VGD
VOD
+ED
GD
VGD
VOD
+ED
FD
LN
+ED
VOD
VGD
GD
+E
VI1
GND
LN-
LN+
Apt. 4
FD
FC
LINE
LC
GND
+E
FB
FA
VO
Doorstation
BVD -40 5A-4
FD
FC
LN
FB
FA
GND
+E
Circuits
BPD24/12-1-1 RVE 4 Monitors
BPD BVD A
BPD24/12-1-1 Outdoor Camera
Outdoor Camera
BVD A Monitors
Monitors
BPD Lock
Circuit length, m
25
0.5
0.25
50
1.0
0.5
0.5
1.0
Min. wire crosssection, mm 2
Figure 10 - 4-apartment video doorphone with outdoor camera and video monitors VIZIT* powered from a group power supply unit
Monitor
VIZIT*
GC
VGC
VOC
+EC
GC
VGC
VOC
+EC
FC
LN
+EC
VOC
VGC
GC
+E
VI1
GND
LN-
LN+
Apt. 3
Distribution Amplifier
RVE-4
Jumper shall be
Z set up
GB
VGB
VOB
+EB
GB
VGB
VOB
+EB
FB
LN
+EB
VOB
VGB
GB
+E
VI1
GND
LN-
LN+
Apt. 2
GA
VGA
VOA
+EA
GA
VGA
VOA
+EA
Power Supply Unit
BPD24 /12- -1
+24V
GND
GND
+12V
+24V
GND
GND
+12V
VI
VG
GND
+12V
FA
LN
+EA
VOA
VGA
GA
+E
VI1
GND
LN-
LN+
Apt. 1 green black red
Monitor
VIZIT*
Monitor
VIZIT*
Monitor
VIZIT*
Outdoor Camera
VIZIT-C70 www.
vizit-group.com
BVD-405A-2, BVD-405A-4, BVD-405CP-2, BVD-405CP-4 Operating Instruction (revision 12)
* - video monitors that may be used in this diagram:
VIZIT-M4 27C
VIZIT-M4 40C
VIZIT-M4 40CM
VIZIT-M4 41M
VIZIT-M4 41M
VIZIT-M4 56C
VIZIT-M4 56CM
VIZIT-M4 57M
GD
VGD
VOD
+ED
GC
VGC
VOC
+EC
GD
VGD
VOD
+ED
GC
VGC
VOC
+EC
FD
LN
+ED
VOD
VGD
GD
FC
LN
+EC
VOC
VGC
GC
+E
VI1
GND
LN-
LN+
Apt. 4
+E
VI1
GND
LN-
LN+
Apt. 3
Distribution Amplifier
RVE-4
Power Supply Unit
BPD 1
+18
-18
-12
+12
Electromechanical lock / strike
12V / 0.6A max.
+E
GND
Jumper shall be
Z set up
GB
VGB
VOB
+EB
GB
VGB
VOB
+EB
FB
LN
+EB
VOB
VGB
GB
+E
VI1
GND
LN-
LN+
Apt. 2
1N4007
GA
VGA
VOA
+EA
GA
VGA
VOA
+EA
FA
LN
+EA
VOA
VGA
GA
+E
VI1
GND
LN-
LN+
Apt. 1
FD
FC
LINE
LC
GND
+E
FB
FA
VO
Doorstation
BVD -40 5CP-4
FD
FC
LN
GND
+E
FB
FA
VI
VG
Power Supply Unit
BPD24 /12- -1
+24V
GND
GND
+12V
+24V
GND
Circuits
BPD24/12-1-1 RVE 4 Monitors
BPD 1 BVD -405 CP -4
BVD -405 CP -4
BVD -405 CP -4 Monitors
BPD 1 Lock
Circuit length, m
25
0.5
0.25
50
1.0
0.5
0.5
1.0
Min. wire crosssection, mm 2
Figure 11 - 4-apartment video doorphone with video monitors powered from a group power supply unit
VIZIT*
Monitor
VIZIT*
Monitor
VIZIT*
Monitor
VIZIT*
Monitor
VIZIT* www.
vizit-group.com
BVD-405A-2, BVD-405A-4, BVD-405CP-2, BVD-405CP-4 Operating Instruction (revision 12)
* - video monitors that may be used in this diagram:
VIZIT-M4 27C
VIZIT-M4 40C
VIZIT-M4 40CM
VIZIT-M4 41M
VIZIT-M4 41M
VIZIT-M4 56C
VIZIT-M4 56CM
VIZIT-M4 57M
GD
VGD
VOD
+ED
Power Supply Unit
BPD 1
+18
-18
-12
+12
Electromechanical lock / strike
12V / 0.6A max.
+E
GND
1N4007
GC
VGC
VOC
+EC
Distribution Amplifier
RVE-4
GB
VGB
VOB
+EB
GB
VGB
VOB
+EB
Jumper shall be
Z set up
GA
VGA
VOA
+EA
GA
VGA
VOA
+EA
FD
FC
LINE
LC
GND
+E
FB
FA
VO
Doorstation
BVD -40 5CP-2
LN
GND
+E
FB
FA
VI
VG
Power Supply Unit
BPD24 /12- -1
+24V
GND
GND
+12V
+24V
GND
Circuits
BPD24/12-1-1 RVE 4 Monitors
BPD 1 BVD -405 -
BVD -405 CP 2
BVD -405 CP 2
BPD 1
Monitors
Lock
Circuit length, m
25
0.5
0.25
50
1.0
0.5
0.5
1.0
Min. wire crosssection, mm 2
Figure 12 - 2-apartment video doorphone
FB
LN
+EB
VOB
VGB
GB
+E
VI1
GND
LN-
LN+
Apt. 2
FA
LN
+EA
VOA
VGA
GA
+E
VI1
GND
LN-
LN+
Apt. 1
Monitor
VIZIT*
Monitor
VIZIT* www.
vizit-group.com
BVD-405A-2, BVD-405A-4, BVD-405CP-2, BVD-405CP-4 Operating Instruction (revision 12)
FUNCTIONAL CHECK AND OPERATING ORDER
Before switching the power on, verify all electric connections.
• Turn the power supply unit(s) on.
• To make a call to the subscriber, press one of the CALL buttons on the doorstation. A call sound is ringing both in the corresponding monitor (apartment handset) and doorstation, while the CALL button remains pressed. Image appears on the monitor’s screen.
Pick up the handset and check duplex intercom.
Check image on the monitor’s screen. Adjust image brightness, contrast and saturation, if needed.
Press the on the monitor (apartment handset) to release the door lock. The doorstation produces a beep, and the lock stays released while the button remains pressed. Release the button to return to the intercom mode.
Note.
When called, the subscriber can press the button to release the door lock without picking up the handset.
The system goes to the stand-by mode after the button is released.
Intercom is available within (60 ± 5) seconds after picking up the handset.
If the handset is not picked up in 60 seconds, the system returns to the stand-by mode automatically .
• One by one check the rest of connected apartment handsets / monitors for intercom, video (for monitors), remote door unlocking function.
SPECIFICATIONS
Operating voltage:
Power consumption:
Dimensions (W)x(H)x(D):
Weight:
Weight with package :
16...25
3
0
VDC
W max.
.3 kg
The built-in camera parameters (BVD40 5CP-x) are given below:
Lens
Angle of view (diagonal)
Scanning system
Colour system
Resolution
Camera Parameters
Pinhole
90 °
СCIR
PAL
700 TVL
0 Lux (IR LED on
Minimal illumination
Day-Night feature
Output voltage
. Lux IR LED off )
YES
1 Vp-p at 75 О hm
OPERATING CONDITIONS
Ambient temperature range :
-
-
BVD
BVD
-40 А
-40 5CP-2(4)
Relative humidity of air:
40°C
- 3 0°C up to to to
+
+
45°C
45°C
98% at 25°C www.
vizit-group.com
BVD-405A-2, BVD-405A-4, BVD-405CP-2, BVD-405CP-4 Operating Instruction (revision 12)