DSC LCD-600 Programming Manual
PDF
Documento
Pubblicità
Pubblicità
PROG RAMMING
GUIDE
O 1993 Digital Security Controls Ltd
1645 Flint Road, Downsview, Ontario M3J 2J6
= = IC D-600 SEC URIIY SIATO М
Printed in Canada 29000145 R2
|
This guide is for use with the LCD-600 software version 2.0.
The LCD-600 may be used with the following DSC control panels:
PC3000/PC2550/PC2500/PC 1550/PC 1500.
List of Available ASCII Characters
bh fe En
= o a O = o
on
rhe Sd &
o
a
0)
a UT"
—J
al
064
087
095
191
=
ro
—
ro
=
No
—
0)
Pa
—
E»
“Jl
255
15. Red Armed LED Display 1. Programming the Panel
The LCD-600 has a red “Armed” LED on the keypad which directly With the panel in the “disarmed” state:
corresponds to the “Armed” light on the LED keypad. e Press [xk], [8].
e When prompted, enter the Installer's Code.
. e The display will read.. F
16. Yellow Trouble LED Display
The LCD-600 has a yellow “Trouble” LED on the keypad which directly
corresponds to the “Trouble” light on the LED keypad. Numeric zone information displayed on the LCD-600 corresponds with the
numbered LED's on the LED keypads. If LED #1 is ON then the LCD-600
will display a “1”. If LED #2 is ON then the LCD-600 will display a “2” and
17.Open Zone Indicator so on.
While in the bypass mode, any zone that is not bypassed but was open when With the PC3000, the numbers 10 through 15 are represented by their
the user enters [+], [1] will be seen on the display as follows hexadecimal or “HEX” equivalents. Thus when LED #10 is ON, the LCD-600
. will display an “А”, #11 а “В”, #12 - “С”, #13 - “D”, #14 - “Е” and #15 - "F”.
an e На LED keypad has no LED's ON, then the LCD-600 will display a “0”.
If the same zone is already bypassed or the user bypasses the zone it will then
say BP instead of OP.
1 The LCD-600 will display this message when expecting
| data using numbers “1” to “9”.
1 The LCD-600 will display this message when expecting
| hexadecimal data.
18. Downloading a LCD Message
The LCD is capable of accepting a downloaded message from the Programming with an LCD-600 requires exactly the same entries as when
downloading software. The downloading package must be at least the DLS-1 programming with an LED keypad. Refer to the programming section of the
V2.1 or higher. Only the PC3000 7.4 or later or the PC2550 are capable of control panel's Installation Manual.
accepting downloaded messages. The message can be 2 lines of 16
characters each. , ,
2. Keypad Function Assignments
Each key, except 8 and 9 is assigned a function for use in LCD-600 zone
label programming.
A sample of a downloaded message is..
This message will initially be displayed only when the panel is either fully © (2) (3) < [>
armed or fully disarmed. Once the message is displayed, it will stay on until the CURSOR INSERT CORSCR PREVIOUS NEXT
panel is armed and disarmed three times. There is no recall feature once the (4) 6) O
message goes off the screen. CASE DELETE DELETE FIRE
TOGGLE TO END
© @)
Note: CHARACTER NOT NOT AUXILIARY
» = = . . р ENTRY USED USED
1. Any time that there is information that can be viewed by toggling the a © O CF]
arrow keys, “< >” will be flashing. ABORT CLEAR/ SAVER PANIC
2. The two minute timeout feature in the panel should not be used in ЕО HOME EMT
conjunction with the LCD-600.
3. Programming Zone Labels
With the panel in the “disarmed” state, enter the LCD keypad programming
mode as follows:
Press [%], [8] and when prompted, enter the Installer's Code.
The display will read..
Press EITHER scroll key to enter the LCD keypad programming section.
The display will read..
Enter the zone number for the zone label you wish to add, change or delete.
PC3000 enter two digits 01 through 16.
РС2550 conorocorconororonnanonoso 01 ............ 08.
PC2500 .…....................... 01 ............ 08.
РС1550 oes 01 ............ 06.
РС1500 ......... ен 01 ........... 06.
The display will read..
Default label (zone +), or..
A programmed label “text”, or..
Blank if label erased.
Note: The cursor will always appear under the first character.
To change or add zone label text:
1.Move cursor to the character you wish to change by using the “cursor left”
[1] or “cursor right” [3] keys.
2.Use the ‘next character’ [>] key to move forward through the alphabet and
the ‘previous character’ [<] key to move backwards in order to select the
desired character. The characters ‘a’ - 'Z', ‘A’ - ‘Z’ and ‘Q’ - ‘9’ can be
selected with these keys. Use the “case toggle” [4] to select either ‘UPPER’
or ‘lower’ case characters.
3.A table inside the back cover shows the complete list of characters
available. If a character is needed that is not selectable by the [<] [>] keys,
then move the cursor to the location where you want the character and press
[7] followed by the 3 digit code under the character.
4.Move the cursor to each location in turn and bring up the desired character.
Note: Maximum label length is 12 characters.
Then wire the LCD’s as shown below...
DSC SECURITY CONTROL PANEL
0 OOD QD ©
4 3
KEYPAD
RED BLK YEL GRN
t {
4 $
————= Line removed from
| | | GRN terminal
LCD-600 #1 LCD-600 #2
PROGRAMMED TO BE PROGRAMMED
After the LCD's are wired as shown, LCD #2 will have the following
message..
Then enter [5] [0] again on LCD #1 and the following message will appear..
|
and LCD #2 will have.. These two digits will scroll from 91 to E7.
Once programming is complete, the keypads will display..
Reconnect the green wires from the keypads to the control panel and the
keypads will return to normal display status.
Summary:
Step 1 - Enter [5] [0] on keypad #1
Step 2 - Remove green wire from panel
Step 3 - Enter [5] [0] on keypad #1 again
Step 4 - Keypad #1 sends data to keypad #2
Step 5 - Reconnect green wire to panel
11.User Scroll Mask Off Option
With the “Enter Selection” message displayed, enter [2] [3]. The display will
reao..
The Installer can mask off the viewing of unwanted display options by the
user for the [ak] [6], user options, (select) mode. If the option number is on
then that message will be displayed.
Number Message
1 Clock
Auto-Arm Time
Quick Arm On/Off
Auto Arm On/Off
Chime On/Off
Bell Test
User Call Up
For Future Use
CON OO & © mn
Press [#] to save the new configuration and return to the “Enter Selection”
message.
12.Reset LCD EEPROM to Factory Defaults
With the “Enter Selection” message displayed, enter [9] [7]. The LCD-600 will
reset to factory defaults.
13. View Software Version
Viewing the version number of the software in the LCD-600 at any time other
than on power-up can be done by entering [9] [9] at the “Enter Selection”
message. The display will read..
14.Programming Other LCD Keypads
If the system has more than one LCD-600, only one needs to be programmed
as described above. The other LCD-600’s may be programmed using the first
keypad as a master. Enter the copy mode on the programmed LCD-600 by
pressing [5] [0] with the “Enter Selection” message on the display. Then the
display on the programmed LCD-600 will read..
5.When you have the zone label completed, press [#]. This will save the
new zone label and return you to the “Enter Selection” message..
6. At this point you can choose to add or change another zone label or to go
on to the remaining programming steps.
EDITING KEYS FUNCTION
2 Pressing this key will allow a character to be inserted at the
INSERT cursor location. The character at the cursor and all characters
to the right of the cursor will be moved one space to the right
leaving an open space for a new character.
5 Pressing this key will delete the character above the cursor
DELETE and characters to the right will all shift one space left.
6 Pressing this key will erase all of the characters to the right
DELETE of the cursor.
* Pressing this key aborts the editing routine and any
ABORT changes made to this point will not be saved. You will also
EDIT be returned to the “Enter Selection” message.
0 Pressing this key will clear the entire message and place
CLEAR/ the cursor in the leftmost position.
HOME
4. Programming the “F”, “A”, and “P” Keys and
Display Alarms While Armed.
With the “Enter Selection” message on the display, enter “O0”.
The display will read..
If all options are off.
If all options are on.
If “A” and “Display Alarms While Armed” are on.
If light ‘1’ is on the Fire key is enabled.
If tight ‘2’ is on the Auxiliary key is enabled.
If light ‘3° is on the Panic key is enabled.
Light ‘4’ should be on if “Display Alarms While Armed” is on in the panel
System Options. “Display Shunted Zones While Armed” is not supported by
the LCD-600.
5. Programming the Utility Output Label
With the “Enter Selection” message on the display, enter [1] [7]. The display
will read..
Program the message as described in Section 3 of this manual. (12 characters
max.) This message will appear when the user enters the utility output command,
[ak], [7] and will remain on for the duration of the output operation, (approx. 5
seconds).
Press [#] to save the new message and return to the “Enter Selection” message.
Split Arm Side Labels
1. With the “Enter Selection” message displayed, enter [1] [8]. The display will
read
Program the message as described in Section 3 of this manual. Press [#]
twice to return to the ready mode. To memorize this split mask, arm the side
of the panel corresponding to the label in section [1] [8]. Any time only this
side of the panel is armed, this message will be displayed.
2. Return to the “Enter Selection” message and enter [1] [9]. The display will read..
Program the message as described in Section 3 of this manual. This
message will appear if only the other section of the system is armed.
Note: Any time the split arming zone configuration is changed in the
panel, the mask must be re-memorized. To clear the split arm mask, enter
[9] [6] when the selection message is on the screen. Then arm and disarm
the side corresponding to section [1] [8].
3.When the panel is fully armed the following message will be on the display..
Other messages will toggle with this one. These are Fire Zone Trouble, At-
Home Arming, and Bypass Active.
Message Language
some models of the LCD-600 can display messages in different languages.
The languages available can be viewed by pressing and holding both arrow
keys. The keypad will beep three times and will display “language < >”. Press
either arrow key to scroll through the available languages. The list contains
only the English name of each language. Pressing the [#] key when the desired
language is displayed, will change the display messages to that language.
8. Backlite Control
With the “Enter Selection” message displayed, enter [2] [0].
The display will read..
Toggling the right arrow key will decrease the backlite level to @. Toggling
the left arrow key increases the backlite level to 9.
Press [#]to save the new level and return to the selection message.
9. Contrast Control
With the “Enter Selection” message displayea, enter [2] [1].
The display will read..
Toggling the right arrow key will decrease the contrast level to ®. Toggling
the left arrow key increases the contrast level to 9.
Press [#] to save the new level and return to the “Enter Selection” message.
10.Masking Off Unwanted User Options
With the “Enter Selection” message displayed, enter [2] [2]. The display will
read..
The Installer can mask off the viewing of unwanted display options by the
user for the [%] (select) mode. If the option number is on, then that
message will be displayed.
Number Message
1 Trouble
Memory
Reset Sensors (User Call Up; PC 1500/1550)
Access Codes
User Functions
Utility Message (programmable)
At-Home Arm
Quick Arm
Press [#] to save the new configuration and return to the “Enter Selection”
message.
CON MO B W PO
">
/
Scarica
Solo un promemoria. Puoi visualizzare il documento qui. Ma soprattutto, la nostra IA l''ha già letto. Può spiegare cose complesse in termini semplici, rispondere alle tue domande in qualsiasi lingua e aiutarti a navigare rapidamente anche nei documenti più lunghi o complicati.
Pubblicità