Operating Instructions
Sophos Switch Series
Operating Instructions
Foreword
We are pleased to welcome you as a new customer of our Sophos Switch Series.
To install and configure your switch you can use the following documents:
Ì Sophos Switch Quick Start Guide: Connection to the system peripherals in a few steps
Ì Operating Instructions: this document
Ì Sophos How-To Library: Installing and configuring your switch
The Quick Start Guide and the Safety Instructions are also delivered in printed form together with the switch. The instructions must be read carefully prior to using the switch and should be kept in a safe place.
You may download all user manuals and additional documentation from the support webpage at: sophos.com/support
Security Symbols
The following symbol and its meaning appears in the Hardware Quick Start Guide, Safety
Instructions and in these Operating Instructions.
Caution and Important note. If these notes are not correctly observed:
Ì This is dangerous to life and the environment
Ì The switch may be damaged
Ì The functions of the switch will be no longer guaranteed
Ì Sophos shall not be liable for damages arising from a failure to comply with the Safety Instructions
Designed Use
The Sophos switches are developed for use in networks and may be operated as a standalone switches. They can be used in commercial, industrial and residential environments.
The CS110-24,CS110-24FP, CS110-48, CS110-48P, CS110-48FP, CS210-8FP, CS210-
24FP, CS210-48FP models are EMC Class A devices. The CS101-8 and CS101-8FP models are EMC Class B devices.
The switch must be installed pursuant to the current installation notes. Otherwise failurefree and safe operation cannot be guaranteed. The EU declaration of conformity is available at the following address:
Sophos Technology GmbH
Gustav-Stresemann-Ring 1
65189 Wiesbaden
Germany
Sophos Switch Series 1
Operating Instructions
Sophos Switch Series
CE Labeling, FCC and Approvals
The Sophso switches comply with CB, UL, CE, FCC, ISED, RCM, VCCI, BSMI, NOM, Anatel † ,
KC † .
Important note: For computer systems to remain CE and FCC compliant, only CE and FCC compliant parts may be used. Maintaining CE and FCC compliance also requires proper cable and cabling techniques.
Operating Elements and Connections
CS101-8x
*
2 x 1 Gbps
SFP ports
LED/Mode button
(PoE model only)
Status LEDs
8 x 10/100/1000
Mbps copper ports
Power supply connector
Power switch
Ground connector
CS110-xx
**
Status LEDs
24/48 x 10/100/1000 Mbps copper ports
LED/Mode button (PoE model only)
Console port
4 x 1/10 Gbps
SFP+ ports
CS210-8FP
Status LEDs
Power cable connector
LED/Mode button
Console port
8 x 100/1000/2500
Mbps copper ports
4 x 1/10 Gbps
SFP+ ports
CS210-24/48FP
***
Status LEDs
Power supply connector
LED/Mode button
Console port
24/48 x 10/100/1000
Mbps copper ports
8/16 x 100/1000/2500
Mbps copper ports
4 x 1/10 Gbps
SFP+ ports
Power cable connector
† Certification may not be available from launch
* CS101-8FP model shown, other models may vary
** CS110-48FP model shown, other models may vary
*** CS210-48FP model shown, other models may vary
2
Operating Instructions
Interfaces (front)
Model
CS101-8
CS101-8FP
CS110-24
CS110-24FP
CS110-48
CS110-48P
CS110-48FP
CS210-8FP
CS210-24FP
CS210-48FP
24
24
48
48
48
0
16
32
1G LAN Ports
8
8
2.5G LAN ports SFP/SFP+ Fiber ports Max. PoE Capacity
0
0
0
0
0
8
8
0
0
16
2 SFP
2 SFP
4 SFP+
4 SFP+
4 SFP+
4 SFP+
4 SFP+
4 SFP+
4 SFP+
4 SFP+
N/A
110W
N/A
410W
N/A
410W
740W
240W
410W
740W
Note: All ports on a PoE model are PoE capable according to 802.3af/at standard, CS210-8FP also supports the 802.3bt standard
Max. 15W/30W/60W PoE Devices
N/A
7/3/-
N/A
24/13/-
N/A
26/13/-
48/24/-
8/8/4
24/13/-
48/24/-
Other Interfaces
COM
Reset
LED Mode
(PoE models only)
Type
RJ45
Button
Button
Comment
You can connect a serial console to the RJ45 COM port to access the Command Line Interface (CLI).
The required connection settings are:
Ì Bits per second: 115,200
Ì Data bits: 8
Ì Parity: N (none)
Ì Stop bits: 1
Press and hold the reset button for 7 seconds to reset the switch to the factory default settings. All configuration including the login password will be reset.
Press to switch the meaning of the left LED on each RJ45 port (labeled with ‘LED Mode’) between LAN Mode and PoE Mode.
Sophos Switch Series 3
Operating Instructions
Technical Specifications
CS101-8 CS101-8FP CS110-24 CS110-24FP
Physical Specification
Form factor
#10/100/1000
Base-T (RJ45) Ports
#10/100/1000/2500
Base-T (RJ45) Ports
#SFP 1G Ports
#SFP+ 10G Ports
RJ-45 Console port
Switching Capacity Duplex
(Gbps)
MAC Address Table
Memory (MB)
Flash (MB)
Desktop
8
0
2
0
0
20
Desktop
8
0
2
0
0
20
1U
24
0
0
4
1
128
1U
24
0
0
4
1
128
Packet Buffer Memory
VLANs
PoE Power Budget
PoE capable Ports
PoE Standard
Max. PoE Devices
Power Supply Rating
Power Supply Type
AC Input
DC Output
Power Adapter Efficiency
8K
256MB
NOR 32MB
512K
Support for up to 256
VLANs simultaneously
(out of 4096 VLAN IDs) n/a n/a n/a n/a
12W
External DC Adapter
100-240VAC,
0.3A max@50-60Hz
+12V 1.0A 12W
100VAC/0.13A (80.45%)
240VAC/0.08A (81.66%)
3.76W/12.82 BTU/hr
8K
256MB
NOR 32MB
512K
Support for up to 256
VLANs simultaneously
(out of 4096 VLAN IDs)
110W
1 to 8
802.3af/802.3at
7 (15.4W)/3 (30W)
150W
External AC/DC Adapter
100-240VAC,
2.0A@50/60Hz
150W 54V/2.78A
100VAC/1.48A (94.5%)
240VAC/0.64A (95.9%)
4.86W/16.57 BTU/hr
16K
512MB
NOR 2MB
NAND 128MB
1.5M
Support for up to 256
VLANs simultaneously
(out of 4096 VLAN IDs) n/a n/a n/a n/a
25W
Internal PSU
100-240VAC,
0.7A@50/60Hz,
25W 12V/2.09A
100VAC/0.5405A (88.26%)
240VAC/0.2875A (88.55%)
10.67W/36.3847 BTU/hr
16K
512MB
NOR 2MB
NAND 128MB
1.5M
Support for up to 256
VLANs simultaneously
(out of 4096 VLAN IDs)
410W
1 to 24
802.3af/802.3at
24 (15.4W)/13 (30W)
480W
Internal PSU
100-240VAC,
7A@50/60Hz
480W 12V/5A, 54V/7.8A
100VAC/9.03A (86.81%)
240VAC/3.78A (91.55%)
20.41W/69.5981 BTU/hr Power Consumption
Idle Power (typical)
Power Consumption
Max. Power (typical)
Dimensions
Width x Height x Depth
Weight (unpacked)
Weight (packed)
Mounting
6.96W/23.733 BTU/hr
240 x 27 x 105 mm
0.636 kg
0.99 kg
Wall mount
(screws incl.)
147.1W/501.6 BTU/hr
240 x 27 x 105 mm
0.636 kg
1.45 kg
Wall mount
(screws incl.)
24.41W/83.2381 BTU/hr
440 x 44 x 193.3 mm
2.3 kg
3.06 kg
Rackmount
(ears and screws incl.)
500.46W/1706.5686 BTU/hr
440 x 44 x 257.3 mm
3.99 kg
4.7 kg
Rackmount
(ears and screws incl.)
Environmental
Fans
Noise level (avg.)
(typical/max operation)
Temperature (operating)
Temperature (storage)
Humidity (operating)
Humidity (storage) fanless fanless
0°C to 40°C
-20°C to 70°C
10% to 90% RH
(non-condensing)
5% to 90% RH
(non-condensing)
3,403,414 Hrs fanless fanless
0°C to 40°C
-20°C to 70°C
10% to 90% RH
(non-condensing)
5% to 90% RH
(non-condensing)
866,197 Hrs fanless fanless
0°C to 40°C
-20°C to 70°C
10% to 90% RH
(non-condensing)
5% to 90% RH
(non-condensing)
1,202,125 Hrs
2
45-56 dBA
0°C to 40°C
-20°C to 70°C
10% to 90% RH
(non-condensing)
5% to 90% RH
(non-condensing)
674,102 Hrs MTBF (hours)
(Telcordia SR-332 Issue 3)
Certifications
Safety, EMC, ... CB, UL, CE, FCC, ISED, RCM,
VCCI, BSMI, NOM, Anatel * , KC *
CB, UL, CE, FCC, ISED, RCM,
VCCI, BSMI, NOM, Anatel * , KC *
CB, UL, CE, FCC, ISED, RCM,
VCCI, BSMI, NOM, Anatel * , KC *
CB, UL, CE, FCC, ISED, RCM,
VCCI, BSMI, NOM, Anatel * , KC *
* Certification may not be available from launch
Sophos Switch Series 4
Operating Instructions
CS110-48 CS110-48P CS110-48FP CS210-8FP
Physical Specification
Form factor
#10/100/1000
Base-T (RJ45) Ports
#10/100/1000/2500
Base-T (RJ45) Ports
#SFP 1G Ports
#SFP+ 10G Ports
RJ-45 Console port
Switching Capacity
Duplex (Gbps)
MAC Address Table
Memory (MB)
Flash (MB)
Packet Buffer Memory
VLANs
PoE Power Budget
PoE capable Ports
PoE Standard
Max. PoE Devices
Power Supply Rating
Power Supply Type
AC Input
DC Output
Power Adapter Efficiency
1U
48
0
0
4
1
176
1U
48
0
0
4
1
176
1U
48
0
0
4
1
176
1U
0
8
0
4
1
60
32K
512MB
NOR 2MB
NAND 128MB
2M
Support for up to 256
VLANs simultaneously
(out of 4096 VLAN IDs)
32K
512MB
NOR 2MB
NAND 128MB
2M
Support for up to 256
VLANs simultaneously
(out of 4096 VLAN IDs)
32K
512MB
NOR 2MB
NAND 128MB
2M
Support for up to 256
VLANs simultaneously
(out of 4096 VLAN IDs)
8K
512MB
NOR 16MB
NAND 128MB
512K
Support for up to 256
VLANs simultaneously
(out of 4096 VLAN IDs) n/a n/a n/a n/a
60W
410W
1 to 48
802.3af/802.3at
26 (15.4W)/13 (30W)
480W
740W
1 to 48
802.3af/802.3at
48 (15.4W)/24 (30W)
900W
240W
1 to 8
802.3af/802.3at/802.3bt
8 (15.4W)/8 (30W)/4 (60W)
300W
Internal PSU Internal PSU Internal PSU Internal PSU
100-240VAC, 1.5A@50/60Hz 100-240VAC, 7A@50/60Hz 100-240VAC, 12A@50/60Hz 100-240VAC, 4A@50/60Hz
60W 12V/5A 12V/5A;-54V/7.8A
12V/8.3A;-54V/14.8A
12V/5.83A;-54V/4.63A
100VAC/0.8535A (91.00%)
240VAC/ 0.4756A (91.96%)
17.28W/58.9248 BTU/hr
100VAC/4.823A (86.67%)
240VAC/1.956A (91.15%)
29.8W/101.618 BTU/hr
100VAC/9.03A (93.01%)
240VAC/3.78A (96.61%)
32.00/109 BTU/hr
100VAC/2.99A (84.84%)
240VAC/1.20A (88.08%)
31.2W/106.392 BTU/hr Power Consumption
Idle Power (typical)
Power Consumption
Max. Power (typical)
Dimensions
Width x Height x Depth
Weight (unpacked)
Weight (packed)
Mounting
43.92W/149.7672 BTU/hr
440 x 44 x 257.3 mm
3.6 kg
4.33 kg
Rackmount
(ears and screws incl.)
476.3W/1624.183 BTU/hr
440 x 44 x 310 mm
4.85 kg
5.94 kg
Rackmount
(ears and screws incl.)
885.00W/3018 BTU/hr
440 x 44 x 310 mm
4.85 kg
5.94 kg
Rackmount
(ears and screws incl.)
299W/1019.59 BTU/hr
330 x 44 x 230 mm
2.34 kg
3.11 kg
Rackmount
(ears and screws incl.)
Environmental
Fans
Noise level (avg.)
(typical/max operation)
Temperature (operating)
Temperature (storage)
Humidity (operating)
Humidity (storage)
1
45-56 dBA
0°C to 40°C
-20°C to 70°C
10% to 90% RH (Non-
Condensing)
5% to 90% RH
(non-condensing)
358,658 Hrs
3
48-60 dBA
0°C to 40°C
-20°C to 70°C
10% to 90% RH (Non-
Condensing)
5% to 90% RH
(non-condensing)
375,779 Hrs
3
48-60 dBA
0°C to 40°C
-20°C to 70°C
10% to 90% RH (Non-
Condensing)
5% to 90% RH
(non-condensing)
376,912 Hrs
2x Smart fan
45-46 dBA
0°C to 40°C
-20°C to 70°C
10% to 90% RH (Non-
Condensing)
5% to 90% RH
(non-condensing)
391388 Hrs MTBF (hours)
(Telcordia SR-332 Issue 3)
Certifications
Safety, EMC, ... CB, UL, CE, FCC, ISED, RCM,
VCCI, BSMI, NOM, Anatel * , KC *
CB, UL, CE, FCC, ISED, RCM,
VCCI, BSMI, NOM, Anatel * , KC *
CB, UL, CE, FCC, ISED, RCM,
VCCI, BSMI, NOM, Anatel * , KC *
CB, CSA, CE, FCC, ISED, RCM,
VCCI, BSMI, NOM, Anatel * , KC *
* Certification may not be available from launch
Sophos Switch Series 5
Operating Instructions
LED Status
Status LEDs
Power
Fault
PoE Max
LAN Mode
PoE Mode *
*
Green
Amber
Amber
Green
Green
Solid
Off
Solid
Off
Solid
Off
Solid
Solid
Power On
Power Off
Error
Normal Behavior
The power requested by PoE devices exceeds total PoE limit of the switch. No additional devices can be powered.
Additional PoE devices may still be powered
The left LED on RJ45 ports indicates Speed
The left LED on RJ45 ports indicates PoE status
* By pressing the “LED mode” button you can switch the meaning of the left LED on each RJ45 port (labeled with “mode”) between LAN Mode and PoE Mode.
LEDs on each RJ45 Ethernet Connector
LK/AT
(Link/Activity)
(Right LED)
Green Solid
Flashing
Off
Solid
Off
1. Ethernet port has established link.
2. Good connection between the ethernet port and connected device.
The port is sending or receiving network data.
1. The adapter and switch are not receiving power.
2. No connection between both ends of network.
3. Network drivers have not been loaded or do not function correctly.
Ethernet port is operating at 1000 Mbps.
Ethernet port is operating at 100 0r 10 Mbps (if LK/AT LED is active).
CS101-xx Models
Speed
(Left LED)
[on PoE models: LED Mode button not pressed]
Green
1G Ports on CS110-xx and CS210-xx Models
Green
Amber
Speed
(Left LED)
[on PoE models: LED Mode button not pressed]
2.5G Ports on CS210-xx Models
Speed
(Left LED)
[on PoE models: LED Mode button not pressed]
CS101-8FP (PoE) Models only
Mode
(Left LED)
[LED Mode button pressed]
Green
Amber
Green
CS110/210 P/FP (PoE) Models only
Mode
(Left LED)
[LED Mode button pressed]
Green
Amber
Solid
Solid
Off
Solid
Solid
Off
Solid
Off
Solid
Solid
Off
Ethernet port is operating at 1000 Mbps.
Ethernet port is operating at 100 Mbps.
Ethernet port is operating at 10 Mbps (if LK/AT LED is active).
Ethernet port is operating at 2500 Mbps.
Ethernet port is operating at 1000 or 100 Mbps.
Ethernet port has no link
PoE switch provides power to the port
No power is provided to the port
PoE switch provides power to the port
Error
No power is provided to the port
LEDs on each SFP/SFP+ Ethernet Connector
LK/AT
(Link/Activity)
Green
CS110/CS210-xx Models
Speed
(Left LED)
Green
Amber
Solid
Flashing
Off
Solid
Solid
1. Ethernet port has established link.
2. Good connection between the ethernet port and connected device.
The port is sending or receiving network data.
1. The adapter and switch are not receiving power.
2. No connection between both ends of network.
3. Network drivers have not been loaded or do not function correctly.
Ethernet port is operating at 10 Gbps.
Ethernet port is operating at 1 Gbps.
Please note: Additional LED blinking sequences not listed above indicate specific maintenance processes such as firmware updates. For more information, please check additional Sophos documentation resources.
Sophos Switch Series 6
Operating Instructions
Putting into Operation
Caution: Risk of explosion if battery is replaced by an incorrect type. Dispose of used batteries according to the instructions.
Scope of Supply
The supplied parts are indicated in the Quick Start Guide.
Mounting Instructions
All models except CS101-8x are designed for use in racks. Please consider the following security tips:
Important note: Functional reliability outside of a rack cannot be guaranteed.
Warnings and Precautions
The switch can be operated safely if you observe the following notes and the notes on the switch itself.
Rack Precautions
Ì Ensure that the leveling jacks on the bottom of the rack are fully extended to the floor with the full weight of the rack resting on them.
Ì In single rack installation, stabilizers should be attached to the rack.
Ì In multiple rack installations, the racks should be coupled together.
Ì Always make sure the rack is stable before extending a component from the rack.
Ì You should extend only one component at a time—extending two or more simultaneously may cause the rack to become unstable.
General Server Precautions
Ì Installation must be performed by qualified personnel
Ì Review the electrical and general safety precautions that came with the components you are adding to your switch.
Ì Determine the placement of each component in the rack before you install the rackmount ears.
Ì Install the heaviest server components on the bottom of the rack first, and then work up.
Ì Allow the hot plug power supply modules to cool before touching them.
Ì Always keep the rack‘s front door, all panels and server components closed when not servicing to maintain proper cooling.
Sophos Switch Series 7
Operating Instructions
Rack Mounting Considerations
Ì Ambient operating temperature: If installed in a closed or multi-unit rack assembly, the ambient operating temperature of the rack environment may be greater than the ambient temperature of the room. Therefore, you should install the equipment in an environment compatible with the manufacturer’s maximum rated ambient temperature.
Ì Reduced airflow: Equipment should be mounted into a rack with sufficient airflow to allow cooling.
Ì Mechanical loading: Equipment should be mounted into a rack so that a hazardous condition does not arise due to uneven mechanical loading.
Ì Circuit overloading: Consideration should be given to the connection of the equipment to the power supply circuitry and the effect that any possible overloading of circuits might have on overcurrent protection and power supply wiring. Appropriate consideration of equipment nameplate ratings should be used when addressing this concern.
Ì Reliable ground: Reliable grounding must be maintained at all times. To ensure this, the rack itself should be grounded. Grounding screws for the switch are on the rear of the chassis. Chassis Grounding is required. Particular attention should be given to power supply connections other than the direct connections to the branch circuit (i.e., the use of power strips, etc.).
Rack Mounting Instructions
To mount the switch to the rack you need the delivered rack-mount kits. There are a variety of rack units on the market, which may mean the assembly procedure will differ slightly.
You should also refer to the installation instructions that came with the rack unit you are using. Please observe the mounting instructions for your rack.
Important note: Make sure you use the screws supplied with the rack-mount brackets.
Using the wrong screws could damage the hardware switch and would invalidate your warranty.
1. Attach the rack-mount ears to the switch:
Ì Place the switch on a hard flat surface with the front panel facing you.
Please Note: There are two types of mounting brackets supplied with your switch. Use the short brackets if you intend to also use sliding rails which are available as an optional accessory from your Sophos partner. Use the long mounting brackets if you don’t want to use additional sliding rails or any other fixation for the switch.
Ì Attach the rack–mount brackets to the left and right side of the switch with the supplied screws.
Ì Make sure the brackets are properly attached to the switch.
Sophos Switch Series 8
Operating Instructions
Important note: Please check the technical specs above for the min. and max. rack depth.
2. Choose the rack location:
Ì Leave enough clearance in front of the rack so that you can open the front door completely (~60 cm/25 inches).
Ì Leave approximately 80 cm/30 inches of clearance in the back of the rack to allow for sufficient airflow and ease in servicing.
Ì This product is for installation only in a restricted access location
(dedicated equipment rooms, service closets and the like).
3. Install the sliding rails (optional):
Ì Please refer to the dedicated Sliding Rails Mounting Instructions shipped with the switch.
Please note: If you are using the optional external Power Supply which will be mounted to the rear of your switch, we strongly recommend using the optional sliding rails.
4. In order to prevent the unit from unintentionally sliding out of the rack we strongly recommend fixing the rack-mount brackets to the front rackmount posts by using screws and nuts supplied with your rack.
Connection and Configuration
How to connect the switch is described in the Hardware Quick Start Guide. For configuration you can follow the initial setup wizard described in the WebAdmin Quick Start
Guide or cancel it and perform a manual setup (see the Sophos Firewall How-To Library ).
SFP/SFP+ Ports
Sophos switches models offer a variety of SFP/SFP+ ports allowing you to plugin various
GBICs (transceivers) to connect to fiber or copper networks. The abbreviation SFP GBIC stands for small form-factore plugable GigaBit interface converter, a flexible interface which changes electronic signals into optical signals. The converters used with the switch are often also called Mini-GBIC or New GBIC.
To use SFP/SFP+ ports, you will need the appropriate transceivers or DAC cables
(combining transceivers and cables into one). These are not delivered with the switch but available through your Sophos partner. There are different module types, and the required type is determined by the existing network.
Caution: The SFP and SFP+ ports use lasers to transmit signals over fiber optic cable. The lasers are compliant with the requirements of a Class 1 Laser equipment and are inherently eye-safe in normal operation. However, you should never look directly at a transmit port when it is powered on. Always install appropriate and UL approved Laser Class I
Transceivers, rated 3.3Vdc, max. 1W, in the fiber ports before using the fiber ports.
Sophos Switch Series 9
Operating Instructions
Installing a SFP/SFP+ module
Please read the operation manual for the module. Carefully insert the module into the port until it engages. The interface is immediately ready for use.
Removing a SFP/SFP+ module
1. Remove the optical cable from the module which you wish to remove.
2. Remove the module carefully from the port.
Depending on when you purchased your module, it may have any of three different release mechanisms: a plastic tab on the bottom of the module, a wire bail, or a plastic collar around the module.
Please read the operation manual to the module.
Serial Console
You can connect a serial console to the RJ45 port to access the CLI. To connect a serial
DB9-port of your PC to the RJ45 COM port please use the supplied RJ45 to DB9 Adapter cable. If you want to connect to a USB port of your PC you will need an additional USB
Type-A to DB9 Adapter cable.
To log on to the console you can use, for instance, the Hyperterminal terminal program which is included with most versions of Microsoft Windows, or PuTTy. The required connection settings are:
Ì Bits per second: 115,200
Ì Data bits: 8
Ì Parity: N (none)
Ì Stop bits: 1
Ì Flow Control: None
After connecting, press Enter on your keyboard to connect to the CLI. Sign in using the username “admin” and the unique password for this switch.
Sophos Switch Series 10
Operating Instructions
United Kingdom and Worldwide Sales
Tel: +44 (0)8447 671131
Email: [email protected]
North American Sales
Toll Free: 1-866-866-2802
Email: [email protected]
© Copyright 2021. Sophos Ltd. All rights reserved.
Registered in England and Wales No. 2096520, The Pentagon, Abingdon Science Park, Abingdon, OX14 3YP, UK
Sophos is the registered trademark of Sophos Ltd. All other product and company names mentioned are trademarks or registered trademarks of their respective owners.
21-12-15 OI-EN (DD)
Australia and New Zealand Sales
Tel: +61 2 9409 9100
Email: [email protected]
Asia Sales
Tel: +65 62244168
Email: [email protected]
Download
Anúncio