PRELIMINARY PIM60.245 24V, 2.5A, 60W, SINGLE PHASE INPUT PIANO-Series POWER SUPPLY 100-240V Wide-range Input NEC CLASS 2 Compliant Cost Optimized without Compromising Quality or Reliability Width only 36mm Efficiency up to 91.8% Low No-load Power Losses Full Power Between -10°C and +60°C Large Screw Terminals 3 Year Warranty PRODUCT DESCRIPTION SHORT-FORM DATA The PIM60.245 is a DIN-rail mountable single-phaseinput power supply, which provides a floating, stabilized and galvanically separated SELV/PELV/ES1 output voltage. Output voltage Adjustment range Output current The output fulfils the requirements for a limited power source according to NEC CLASS 2. The device is equipped with screw terminals, which are optimized for large wire sizes. The mechanically robust housing is made of a highgrade, reinforced molded material, which permits surrounding temperatures up to +70°C. The PIANO family is a compact industrial grade DIN-rail power supply series that focus on the essential features needed in today’s industrial applications. The excellent cost/performance ratio does not compromise quality or reliability. ORDER NUMBERS Efficiency Losses Hold-up time Temperature range Size (W x H x D) Weight MAIN APPROVALS Order number: Power Supply Input voltage AC Mains frequency Input current AC Power factor Input inrush current DC 24V Nominal 24 – 28V Factory setting 24.1V 2.5 – 2.1A Below +60°C ambient 1.9 – 1.6A At +70°C ambient Derate linearly between +60°C and +70°C AC 100-240V ±10% 50-60Hz ±6% 1.0 / 0.6A At 120 / 230Vac 0.55 / 0.47 At 120 / 230Vac 15 / 36A peak At 120 / 230Vac, 40°C, cold start 90.7 / 91.8% At 120 / 230Vac 6.2 / 5.4W At 120 / 230Vac 24 / 113ms At 120 / 230Vac -10°C to +70°C 36x90x91mm Without DIN-Rail 220g / 0.49lb For details and a complete approval list see chapter 18. PIM60.245 IEC 62368-1 IIEC 61010-2-201 Ind. Cont. Eq. planned planned Jan. 2020 / Rev 0.1 DS-PIM60.245-EN All figures are typical values at 230Vac 50Hz input voltage, 24V 2.5A output load, 25°C ambient temperature and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 Germany NEC CLASS 2 planned 1/20 PRELIMINARY PIM60.245 24V, 2.5A, 60W, SINGLE PHASE INPUT PIANO-Series INDEX Page 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. Intended Use .......................................................... 3 Installation Instructions ........................................ 4 AC-Input.................................................................. 5 DC-Input.................................................................. 6 Input Inrush Current.............................................. 6 Output .................................................................... 7 Hold-up Time ......................................................... 8 Efficiency and Power Losses ................................. 9 Functional Diagram ............................................. 10 Front Side and User Elements ............................ 10 Connection Terminals ......................................... 11 Lifetime Expectancy ............................................ 12 MTBF ..................................................................... 12 EMC ....................................................................... 13 Page 15. Environment ........................................................ 14 16. Safety and Protection Features ......................... 15 17. Dielectric Strength .............................................. 16 18. Approvals and Fulfilled Standards .................... 17 19. Regulatory Compliance ...................................... 17 20. Physical Dimensions and Weight....................... 18 21. Application Notes................................................ 19 21.1. Charging of Batteries..................................19 21.2. Series Operation ..........................................19 21.3. Parallel Use to Increase Output Power .....19 21.4. Parallel Use for 1+1 Redundancy ..............19 21.5. Operation on Two Phases ..........................19 21.6. Use in a Tightly Sealed Enclosure..............20 The information given in this document is correct to the best of our knowledge and experience at the time of publication. If not expressly agreed otherwise, this information does not represent a warranty in the legal sense of the word. As the state of our knowledge and experience is constantly changing, the information in this data sheet is subject to revision. We therefore kindly ask you to always use the latest issue of this document (available under www.pulspower.com). No part of this document may be reproduced or utilized in any form without our prior permission in writing. Packaging and packaging aids can and should always be recycled. The product itself may not be disposed of as domestic refuse. TERMINOLOGY AND ABREVIATIONS PE and symbol PE is the abbreviation for Protective Earth and has the same meaning as the symbol . Earth, Ground This document uses the term “earth” which is the same as the U.S. term “ground”. T.b.d. To be defined, value or description will follow later. AC 230V A figure displayed with the AC or DC before the value represents a nominal voltage with standard tolerances (usually ±15%) included. E.g.: DC 12V describes a 12V battery disregarding whether it is full (13.7V) or flat (10V) 230Vac A figure with the unit (Vac) at the end is a momentary figure without any additional tolerances included. 50Hz vs. 60Hz As long as not otherwise stated, AC 100V and AC 230V parameters are valid at 50Hz mains frequency. AC 120V parameters are valid for 60Hz mains frequency. may A key word indicating flexibility of choice with no implied preference. shall A key word indicating a mandatory requirement. should A key word indicating flexibility of choice with a strongly preferred implementation. Jan. 2020 / Rev 0.1 DS-PIM60.245-EN All figures are typical values at 230Vac 50Hz input voltage, 24V 2.5A output load, 25°C ambient temperature and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 Germany 2/20 PRELIMINARY PIANO-Series PIM60.245 24V, 2.5A, 60W, SINGLE PHASE INPUT 1. INTENDED USE This device is designed for installation in an enclosure and is intended for commercial use, such as in industrial control, process control, monitoring, measurement, Audio/Video, information or communication equipment or the like. Do not use this device in equipment, where malfunctioning may cause severe personal injury or threaten human life without additional appropriate safety devices, that are suited for the end-application. If this device is used in a manner outside of its specification, the protection provided by the device may be impaired. Do not use this device on AC 100V mains with more than 1.9A load when the application is sensitive to short output voltage dips during mains interruptions even with a length shorter than 20ms. Without additional measures to reduce the conducted emissions on the output (e.g. by using a filter), the device is not suited to supply a local DC power network in residential, commercial and light-industrial environments. No restrictions apply for local DC power networks in industrial environments. Jan. 2020 / Rev 0.1 DS-PIM60.245-EN All figures are typical values at 230Vac 50Hz input voltage, 24V 2.5A output load, 25°C ambient temperature and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 Germany 3/20 PRELIMINARY PIM60.245 24V, 2.5A, 60W, SINGLE PHASE INPUT PIANO-Series 2. INSTALLATION INSTRUCTIONS WARNING - Risk of electrical shock, fire, personal injury or death. Turn power off before working on the device. Protect against inadvertent re-powering. Make sure that the wiring is correct by following all local and national codes. Do not modify or repair the unit. Do not open the unit as high voltages are present inside. Use caution to prevent any foreign objects from entering the housing. Do not use in wet locations or in areas where moisture or condensation can be expected. Do not touch during power-on, and immediately after power-off. Hot surfaces may cause burns. Obey the following installation instructions: This device may only be installed and put into operation by qualified personnel. This device does not contain serviceable parts. The tripping of an internal fuse is caused by an internal defect. If damage or malfunction should occur during installation or operation, immediately turn power off and send unit to the factory for inspection. Install device in an enclosure providing protection against electrical, mechanical and fire hazards. Install the device onto a DIN-rail according to EN 60715 with the input terminals on the bottom of the device. Make sure that the wiring is correct by following all local and national codes. Use appropriate copper cables that are designed for a minimum operating temperature of 60°C for ambient temperatures up to +45°C, 75°C for ambient temperatures up to +60°C and 90°C for ambient temperatures up to +70°C. Ensure that all strands of a stranded wire enter the terminal connection. Unused screw terminals should be securely tightened. The device is designed for pollution degree 2 areas in controlled environments. No condensation or frost is allowed. The enclosure of the device provides a degree of protection of IP20. The enclosure does not provide protection against spilled liquids. The isolation of the device is designed to withstand impulse voltages of overvoltage category III according to IEC 60664-1. The device is designed as “Class of Protection” I equipment according to IEC 61140. Do not use without a proper PE (Protective Earth) connection. The device is suitable to be supplied from TN, TT or IT mains networks. The continuous voltage between the input terminal and the PE potential must not exceed 300Vac. A disconnecting means shall be provided for the input of the device. The device is designed for convection cooling and does not require an external fan. Do not obstruct airflow and do not cover ventilation grid! The device is designed for altitudes up to 5000m (16400ft). Above 2000m (6560ft) the overvoltage category is reduced to level II and a reduction in output current is required. Keep the following minimum installation clearances: 40mm on top, 20mm on the bottom, 0mm left and right side. Increase the 0mm to 15mm in case the adjacent device is a heat source. The device is designed, tested and approved for branch circuits up to 20A without additional protection device. If an external fuse is utilized, do not use circuit breakers smaller than 6A B- or 4A C-Characteristic to avoid a nuisance tripping of the circuit breaker. The maximum surrounding air temperature is +70°C (+158°F). The operational temperature is the same as the ambient or surrounding air temperature and is defined 2cm below the device. The device is designed to operate in areas between 5% and 95% relative humidity. Jan. 2020 / Rev 0.1 DS-PIM60.245-EN All figures are typical values at 230Vac 50Hz input voltage, 24V 2.5A output load, 25°C ambient temperature and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 Germany 4/20 PRELIMINARY PIM60.245 24V, 2.5A, 60W, SINGLE PHASE INPUT PIANO-Series 3. AC-INPUT The device is suitable to be supplied from TN, TT or IT mains networks. Allowed voltage L or N to earth Input frequency Turn-on voltage Shut-down voltage External input protection Nom. AC 100-240V Min. 90-264Vac Continuous operation Min. 264-300Vac For maximum 500ms Max. 300Vac Continuous according to IEC 60664-1 Nom. 50–60Hz ±6% Typ. 75Vac Steady-state value, see Fig. 3-1 Typ. 54Vac Steady-state value, see Fig. 3-1 See recommendations in chapter “Installation Instructions”. Input current Power factor Start-up delay Rise time Typ. Typ. Typ. Typ. AC 100V 1.15A 0.58 50ms 18ms AC 120V 1.0A 0.55 50ms 18ms AC 230V 0.60A 0.47 48ms 18ms Typ. 52ms 52ms 50ms Max. 100mV 100mV 100mV Turn-on overshoot Fig. 3-1 Input voltage range Rated input range Input Voltage max. 500ms VIN Input Current, typ. 0.75 Rise Time Fig. 3-4 Power factor vs. output load at 24V output voltage Power Factor, typ. a) 100Vac b) 120Vac c) 230Vac 1.0 Start-up delay 264V 300Vac Input current vs. output load at 24V output voltage 1.25A - 5% Output Voltage 90V Fig. 3-3 Turn-on behavior, definitions Fig. 3-2 Turn-on Shut-down POUT At 24V, 2.5A, see Fig. 3-3 At 24V, 2.5A, see Fig. 3-4 See Fig. 3-2 At 24V, 2.5A constant current load, 0mF load capacitance, see Fig. 3-2 At 24V, 2.5A constant current load, 2mF load capacitance,, see Fig. 3-2 See Fig. 3-2 a b c 0.5 0.25 0.6 a b 0.5 c 0.4 a: 100Vac b: 120Vac c: 230Vac 0.3 0.2 0 0 0.5 Overshoot AC input AC input range 1.0 1.5 2.0 2.5A Output Current 0.1 0.5 1.0 1.5 2.0 Jan. 2020 / Rev 0.1 DS-PIM60.245-EN All figures are typical values at 230Vac 50Hz input voltage, 24V 2.5A output load, 25°C ambient temperature and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 Germany 2.5A Output Current 5/20 PRELIMINARY PIM60.245 24V, 2.5A, 60W, SINGLE PHASE INPUT PIANO-Series 4. DC-INPUT Do not operate this power supply with DC-input voltage. 5. INPUT INRUSH CURRENT A NTC limits the input inrush current after turn-on of the input voltage. The inrush current is input voltage and ambient temperature dependent. The output load has no impact on the inrush current value. The charging current into EMI suppression capacitors is disregarded in the first microseconds after switch-on. Inrush current Inrush energy Typ. Typ. Max. Max. Max. AC 100V 12Apeak 10Apeak 15Apeak 12Apeak 0.2A2s AC 120V 15Apeak 12Apeak 18Apeak 15Apeak 0.3A2s AC 230V 36Apeak 30Apeak 44Apeak 36Apeak 1.4A2s At 40°C At 25°C At 40°C At 25°C At 40°C ambient, ambient, ambient, ambient, ambient, Fig. 5-1 Typical turn-on behavior at 120Vac and 25°C ambient Fig. 5-2 Zoom into the first inrush peak Fig. 5-3 Typical turn-on behavior at 230Vac and 25°C ambient Fig. 5-4 Zoom into the first inrush peak Jan. 2020 / Rev 0.1 DS-PIM60.245-EN All figures are typical values at 230Vac 50Hz input voltage, 24V 2.5A output load, 25°C ambient temperature and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 Germany cold cold cold cold cold start start start start start 6/20 PRELIMINARY PIM60.245 24V, 2.5A, 60W, SINGLE PHASE INPUT PIANO-Series 6. OUTPUT The output provides a SELV/PELV/ES1 rated voltage, which is galvanically isolated from the input voltage. The output is electronically protected against no-load, overload and short circuit. In case of a protection event, audible noise may occur. The output is designed to supply any kind of loads, including inductive and capacitive loads. Capacitive loads should not be larger than 2500µF with 2.5A or 5000µF with 1.25A additional current load. At heavy overloads (when output voltage falls below 14V), the power supply delivers continuous output current for 25ms. After this, the output is switched off for approx. 145ms before a new start attempt is automatically performed. This cycle is repeated as long as the overload exists. If the overload has been cleared, the device will operate normally. Output voltage Adjustment range Nom. Min. Max. Factory settings Line regulation Load regulation Ripple and noise voltage Output current Typ. Max. Max. Max. Nom. Nom. Nom. Nom. Overload behaviour Overload/ short-circuit current Max. Typ. DC 24V 24-28V 29.0V 24.1V 10mV 100mV 100mVpp 2.5A 2.1A 1.9A 1.6A Continuous current Intermittent current 4.0A 6A Max. 2.5A Output capacitance Typ. 900µF Back-feeding loads Max. 35V Guaranteed value This is the maximum output voltage which can occur at the clockwise end position of the potentiometer due to tolerances. It is not a guaranteed value which can be achieved. ±0.2%, at full load and cold unit Between 90 and 300Vac Between 0 and 2.5A, static value, see Fig. 6-1 Bandwidth 20Hz to 20MHz, 50Ohm At 24V and an ambient temperature below 60°C At 24V and 70°C ambient temperature At 28V and an ambient temperature below 60°C At 28V and 70°C ambient temperature Output voltage above 14Vdc, see Fig. 6-1. Output voltage below 14Vdc, see Fig. 6-1. Continuous current, see Fig. 6-1. Intermitted current peak value for typ. 25ms Load impedance 150mOhm, see Fig. 6-2. Discharge current of output capacitors is not included. Intermitted current average value (R.M.S.) Load impedance 150mOhm, see Fig. 6-2. Included inside the power supply The unit is resistant and does not show malfunctioning when a load feeds back voltage to the power supply. It does not matter whether the power supply is on or off. The absorbing energy can be calculated according to the built-in large sized output capacitor. Jan. 2020 / Rev 0.1 DS-PIM60.245-EN All figures are typical values at 230Vac 50Hz input voltage, 24V 2.5A output load, 25°C ambient temperature and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 Germany 7/20 PRELIMINARY 24V, 2.5A, 60W, SINGLE PHASE INPUT PIANO-Series Fig. 6-1 PIM60.245 Output voltage vs. output current, typ. Output Voltage Adjustment range 28V Fig. 6-2 Output Current 24 C Intermittent current at short circuit, typ. Normal operation Normal operation Short -circuit 6A 14 A: continuous current B: intermittent current B t 0 25 ms Output Current 0 0 1 2 5 4 3 145ms 25 ms 145ms 25 ms 145ms 6A 7. HOLD-UP TIME The hold-up time is the time during which a power supply’s output voltage remains within specification following the loss of input power. The hold-up time is output load dependent. At no load, the hold-up time can be up to several seconds. The green DC OK lamp is also on during this time. Hold-up Time Fig. 7-1 AC 100V 14ms 38ms 11ms 30ms Typ. Typ. Min. Min. Hold-up time vs. input voltage Hold-up Time a 120ms b AC 120V 24ms 58ms 19ms 46ms Fig. 7-2 AC 230V 113ms 230ms 90ms 184ms 2.5A 1.25A 2.5A 1.25A Shut-down behavior, definitions c Zero Transition d 100 At 24V, At 24V, At 24V, At 24V, 80 Input Voltage 60 a) 24V 1.25A typ. b) 24V 1.25Amin. c) 24V 2.5A typ. d) 24V 2.5A min. 40 20 0 90 120 155 190 - 5% Output Voltage Hold-up Time 230Vac Input Voltage Jan. 2020 / Rev 0.1 DS-PIM60.245-EN All figures are typical values at 230Vac 50Hz input voltage, 24V 2.5A output load, 25°C ambient temperature and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 Germany 8/20 PRELIMINARY PIM60.245 24V, 2.5A, 60W, SINGLE PHASE INPUT PIANO-Series 8. EFFICIENCY AND POWER LOSSES Efficiency Average efficiency typ. typ. AC 100V 89.4% 89.3% Power losses typ. typ. typ. 0.3W 3.8W 7.1W AC 120V 90.7% 90.1% AC 230V 91.8% 90.7% 0.3W 3.5W 6.2W 0.4W 3.4W 5.4W At 24V, 2.5A (full load) 25% at 0.68A, 25% at 1.25A, 25% at 1.88A. 25% at 2.5A At no load At 24V, 1.25A (half load) At 24V, 2.5A (full load) The average efficiency is an assumption for a typical application where the power supply is loaded with 25% of the nominal load for 25% of the time, 50% of the nominal load for another 25% of the time, 75% of the nominal load for another 25% of the time and with 100% of the nominal load for the rest of the time. Fig. 8-1 Efficiency vs. output current at 24V, typ. Fig. 8-2 Efficiency Power Losses 92% a b c 90 88 86 84 a) 230Vac b) 120Vac c) 100Vac 82 80 0.5 0 Fig. 8-3 1.0 1.5 2.0 2.5A Output Current Efficiency vs. input voltage at 24V, 2.5A, typ. Efficiency 8W 7 6 5 4 3 2 1 0 c b a a) 230Vac b) 120Vac c) 100Vac 0.5 0 Fig. 8-4 1.0 1.5 2.0 2.5A Output Current Losses vs. input voltage at 24V, 2.5A, typ. Power Losses 93% 92 91 90 89 88 87 85 Losses vs. output current at 24V, typ. 120 155 190 225 260Vac 8W 7 6 5 4 3 2 1 0 85 120 155 190 225 260Vac Input Voltage Input Voltage Jan. 2020 / Rev 0.1 DS-PIM60.245-EN All figures are typical values at 230Vac 50Hz input voltage, 24V 2.5A output load, 25°C ambient temperature and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 Germany 9/20 PRELIMINARY PIM60.245 24V, 2.5A, 60W, SINGLE PHASE INPUT PIANO-Series 9. FUNCTIONAL DIAGRAM Fig. 9-1 Functional diagram Output Voltage Regulator L N Input Fuse & Input Filter Input Rectifier & Inrush Limiter Power Converter Output Filter Output OverVoltage Protection VOUT + + DC-ok LED 10. FRONT SIDE AND USER ELEMENTS Fig. 10-1 Front side A Output Terminals Dual terminals for the negative and positive pole. Both poles are internally connected. + Positive output - Negative (return) output B Input Terminals L Phase (Line) input N Neutral conductor input PE (Protective Earth) input C DC OK LED (green) The LED is on, when the output voltage is above 18V. D Output Voltage Adjustment Potentiometer Jan. 2020 / Rev 0.1 DS-PIM60.245-EN All figures are typical values at 230Vac 50Hz input voltage, 24V 2.5A output load, 25°C ambient temperature and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 Germany 10/20 PRELIMINARY PIM60.245 24V, 2.5A, 60W, SINGLE PHASE INPUT PIANO-Series 11. CONNECTION TERMINALS The terminals are IP20 finger safe constructed and are suitable for field- and factory wiring. Type Solid wire Stranded wire American Wire Gauge Max. wire diameter (including ferrules) Wire stripping length Recommended tightening torque Screwdriver All Terminals Screw terminals Max. 6mm2 Max. 4mm2 AWG 20-10 2.8mm 7mm / 0.28inch 1Nm, 9lb.in 3mm slotted or Phillips No 1 Jan. 2020 / Rev 0.1 DS-PIM60.245-EN All figures are typical values at 230Vac 50Hz input voltage, 24V 2.5A output load, 25°C ambient temperature and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 Germany 11/20 PRELIMINARY PIM60.245 24V, 2.5A, 60W, SINGLE PHASE INPUT PIANO-Series 12. LIFETIME EXPECTANCY The Lifetime expectancy shown in the table indicates the minimum operating hours (service life) and is determined by the lifetime expectancy of the built-in electrolytic capacitors. Lifetime expectancy is specified in operational hours and is calculated according to the capacitor’s manufacturer specification. Please note: The manufacturer of the electrolytic capacitors only guarantees a maximum life of up to 15 years (131 400h). Any number exceeding this value is a calculated theoretical lifetime which can be used to compare devices. Lifetime expectancy AC 100V 115 000h 260 000h 324 000h 734 000h AC 120V 131 000h 263 000h 370 000h 744 000h AC 230V 148 000h 263 000h 419 000h 744 000h At 24V, At 24V, At 24V, At 24V, 2.5A and 40°C 1.25A and 40°C 2.5A and 25°C 1.25A and 25°C 13. MTBF MTBF stands for Mean Time Between Failure, which is calculated according to statistical device failures, and indicates reliability of a device. It is the statistical representation of the likelihood of a unit to fail and does not necessarily represent the life of a product. The MTBF figure is a statistical representation of the likelihood of a device to fail. A MTBF figure of e.g. 1 000 000h means that statistically one unit will fail every 100 hours if 10 000 units are installed in the field. However, it can not be determined if the failed unit has been running for 50 000h or only for 100h. For these types of units the MTTF (Mean Time To Failure) value is the same value as the MTBF value. MTBF SN 29500, IEC 61709 MTBF MIL HDBK 217F AC 100V T.B.D. T.B.D. T.B.D. T.B.D. T.B.D. T.B.D. AC 120V T.B.D. T.B.D. T.B.D. T.B.D. T.B.D. T.B.D. AC 230V T.B.D. T.B.D. T.B.D. T.B.D. T.B.D. T.B.D. At 24V, At 24V, At 24V, At 24V, At 24V, At 24V, 2.5A and 40°C 2.5A and 25°C 2.5A, 40°C; Ground Benign GB40 2.5A, 25°C; Ground Benign GB25 2.5A, 40°C; Ground Fixed GF40 2.5A, 25°C; Ground Fixed GF25 Jan. 2020 / Rev 0.1 DS-PIM60.245-EN All figures are typical values at 230Vac 50Hz input voltage, 24V 2.5A output load, 25°C ambient temperature and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 Germany 12/20 PRELIMINARY PIM60.245 24V, 2.5A, 60W, SINGLE PHASE INPUT PIANO-Series 14. EMC The EMC behavior of the device is designed for applications in industrial environment as well as in residential, commercial and light industry environments. The device complies with EN 61000-6-1, EN 61000-6-2, EN 61000-6-3, EN 61000-6-4, EN 61000-3-2 and EN 61000-3-3. The device complies with FCC Part 15 rules. Operation is subjected to following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Do not use this device on AC 100V mains with more than 1.9A load when the application is sensitive to short output voltage dips during mains interruptions even with a length shorter than 20ms. Without additional measures to reduce the conducted emissions on the output (e.g. by using a filter), the device is not suited to supply a local DC power network in residential, commercial and light-industrial environments. No restrictions apply for local DC power networks in industrial environments. EMC Immunity Electrostatic discharge EN 61000-4-2 Electromagnetic RF field Fast transients (Burst) EN 61000-4-3 EN 61000-4-4 Surge voltage on input EN 61000-4-5 Surge voltage on output EN 61000-4-5 Conducted disturbance Mains voltage dips EN 61000-4-6 EN 61000-4-11 Voltage interruptions Powerful transients EN 61000-4-11 VDE 0160 Contact discharge Air discharge 80MHz-6GHz Input lines Output lines LN N / L PE 8kV 8kV 10V/m 4kV 2kV 2kV 4kV Criterion Criterion Criterion Criterion Criterion Criterion Criterion A A A A A A A ++ PE - PE 0.15-80MHz 0% of 100Vac 40% of 100Vac 70% of 100Vac 0% of 120Vac 40% of 120Vac 70% of 120Vac 0% of 200Vac 40% of 200Vac 70% of 200Vac 0V Over entire load range 1kV 1kV 1kV 10V 0Vac, 20ms 40Vac, 200ms 70Vac, 500ms 0Vac, 20ms 48Vac, 200ms 84Vac, 500ms 0Vac, 20ms 80Vac, 200ms 140Vac, 500ms 5000ms 750V, 1.3ms Criterion Criterion Criterion Criterion Criterion Criterion Criterion Criterion Criterion Criterion Criterion Criterion Criterion Criterion Criterion A A A A A/C C A A C A A A A C A Criterions: A: The device shows normal operation behavior within the defined limits. B: The device operates continuously during and after the test. During the test minor temporary impairments may occur, which will be corrected by the device itself. C: Temporary loss of function is possible. The device may shut-down and restarts by itself. No damage or hazards for the device will occur. A/C: Criterion A for output current below 1.9A and criterion C for output currents above 1.9A. EMC Emission Conducted emission input lines Conducted emission output lines Radiated emission Harmonic input current Voltage fluctuations, flicker EN 55011, EN 55022, FCC Part 15, CISPR 11, CISPR 22 IEC/CISPR 16-1-2, IEC/CISPR 16-2-1 EN 55011, EN 55022, CISPR 11, CISPR 22 EN 61000-3-2 EN 61000-3-3 Class B Limits for local DC power networks not fulfilled. Class B Fulfilled (Class A) Fulfilled, tested with non pulsing constant current loads. Jan. 2020 / Rev 0.1 DS-PIM60.245-EN All figures are typical values at 230Vac 50Hz input voltage, 24V 2.5A output load, 25°C ambient temperature and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 Germany 13/20 PRELIMINARY PIM60.245 24V, 2.5A, 60W, SINGLE PHASE INPUT PIANO-Series Switching Frequencies Main converter 40kHz to 140kHz Input voltage and output load dependent 15. ENVIRONMENT Operational temperature Storage temperature Output de-rating Humidity Atmospheric pressure Altitude Over-voltage category Impulse withstand voltage Degree of pollution Vibration sinusoidal Shock LABS compatibility Corrosive gases Fig. 15-1 -10°C to +70°C (14°F to 158°F) The operational temperature is the ambient or surrounding temperature and is defined as the air temperature 2cm below the device. -40°C to +85°C (-40°F to 185°F) For storage and transportation 0.06A/°C Between +60°C and +70°C (140°F to 158°F) 0.15A/1000m or 5°C/1000m For altitudes above 2000m (6560ft), see Fig. 15-2 The de-rating is not hardware controlled. The user has to take this into consideration to stay below the de-rated current limits in order not to overload the unit. 5 to 95% r.H. According to IEC 60068-2-30 No condensation allowed. 110-54kPa See Fig. 15-2 for details Up to 5000m (16 400ft) See Fig. 15-2 for details II According to IEC 60664-1, for altitudes up to 5000m 4kV (according to over-voltage Input to PE category III) According to IEC 60664-1, for altitudes up to 2000m 2 According to IEC 60664-1, non conductive 2-17.8Hz: ±1.6mm According to IEC 60068-2-6 17.8-500Hz: 2g 2 hours / axis 30g 6ms, 20g 11ms According to IEC 60068-2-27 3 bumps / direction, 18 bumps in total Shock and vibration is tested in combination with DIN-Rails according to EN 60715 with a height of 15mm and a thickness of 1.3mm. As a rule, only non-silicon precipitating materials are used. The unit conforms to the LABS criteria and is suitable for use in paint shops. Compliant to ISA-71.04-1985, Severity Level G3 and IEC 60068-2-60 Test Ke Method 4 for a service life of minimum 10 years in these environments. Output power vs. ambient temp. Fig. 15-2 Allowed Output Current at 24V 2.5A B A 1.9A 2.5A 2.35A 2.05A 0 C B A A... Tamb < 60°C B... Tamb < 50°C C... Tamb < 45°C A...continuous B... short term (max. 300s) 0 -10 Output power vs. altitude Allowed Output Current at 24V +60 +70°C Ambient Temperature Altitude 0 AP*) 110 2000 80 4000 5000m 62 54kPa *) Atmospheric pressure Jan. 2020 / Rev 0.1 DS-PIM60.245-EN All figures are typical values at 230Vac 50Hz input voltage, 24V 2.5A output load, 25°C ambient temperature and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 Germany 14/20 PRELIMINARY PIM60.245 24V, 2.5A, 60W, SINGLE PHASE INPUT PIANO-Series 16. SAFETY AND PROTECTION FEATURES Isolation resistance Output over-voltage protection Min. 500MOhm Min. 500MOhm Min. 500MOhm Typ. Max. 30.5Vdc 32Vdc In case of an internal defect, a redundant circuit limits the maximum output voltage to 32V. The output shuts down. To attempt a restart, turn the input power off for at least 90s. I According to IEC 61140 IP20 According to EN/IEC 60529 Not included MOV For protection values see chapter “EMC”. (Metal Oxide Varistor) Included Not user replaceable slow-blow high-braking capacity fuse 30µA / 60µA At 100Vac, 50Hz, TN-,TT-mains / IT-mains 40µA / 90µA At 120Vac, 60Hz, TN-,TT-mains / IT-mains 70µA / 140µA At 230Vac, 50Hz, TN-,TT-mains / IT-mains 40µA / 70µA At 110Vac, 50Hz, TN-,TT-mains / IT-mains 50µA / 110µA At 132Vac, 60Hz, TN-,TT-mains / IT-mains 100µA / 180µA At 264Vac, 50Hz, TN-,TT-mains / IT-mains Class of protection Degree of ingress protection Over-temperature protection Input transient protection Internal input fuse Touch current (leakage current) Typ. Typ. Typ. Max. Max. Max. At delivered condition between input and output, measured with 500Vdc At delivered condition between input and PE, measured with 500Vdc At delivered condition between output and PE, measured with 500Vdc Jan. 2020 / Rev 0.1 DS-PIM60.245-EN All figures are typical values at 230Vac 50Hz input voltage, 24V 2.5A output load, 25°C ambient temperature and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 Germany 15/20 PRELIMINARY PIM60.245 24V, 2.5A, 60W, SINGLE PHASE INPUT PIANO-Series 17. DIELECTRIC STRENGTH The output voltage is floating and has no ohmic connection to the ground. The output is insulated to the input by a double or reinforced insulation. Type and routine tests are conducted by the manufacturer. Field tests may be conducted in the field using the appropriate test equipment which applies the voltage with a slow ramp (2s up and 2s down). Connect all phaseterminals together as well as all output poles before conducting the test. When testing, set the cut-off current settings to the value in the table below. It is recommended that either the + pole or the – pole shall be connected to the protective earth system. This helps to avoid situations in which a load starts unexpectedly or can not be switched off when unnoticed earth faults occur. Fig. 17-1 Dielectric strength Type test Routine test Input L N B Output + A Earth, PE A - 60s 5s Field test 5s Cut-off current setting for field test B C 2500Vac 3000Vac 1000Vac 2500Vac 2000Vac > 2mA 2500Vac 2000Vac > 2mA 500Vac 500Vac > 6mA C Jan. 2020 / Rev 0.1 DS-PIM60.245-EN All figures are typical values at 230Vac 50Hz input voltage, 24V 2.5A output load, 25°C ambient temperature and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 Germany 16/20 PRELIMINARY PIM60.245 24V, 2.5A, 60W, SINGLE PHASE INPUT PIANO-Series 18. APPROVALS AND FULFILLED STANDARDS IEC 61010 (planned) IEC 62368 (planned) UL 61010-2-201 (former UL 508) (planned) Ind. Cont. Eq. NEC CLASS 2 (planned) NEC CLASS 2 CB Scheme Certificate IEC 61010-2-201 Electrical Equipment for Measurement, Control and Laboratory Use - Particular requirements for control equipment CB Scheme Certificate IEC 62368-1 Audio/video, information and communication technology equipment - Safety requirements Output safety level: ES1 UL Certificate Listed equipment for category NMTR - UL 61010-2-201 Electrical Equipment for Measurement, Control and Laboratory Use Particular requirements for control equipment Applicable for US and Canada E-File: E198865 UL Certificate NEC CLASS 2 - Limited Power Source Listed in the UL 61010-2-201 approval report, investigated according to UL 1310 19. REGULATORY COMPLIANCE CE REACH Directive WEEE Directive EU Declaration of Conformity Trade conformity assessment for Europe The CE mark indicates conformance with the European - RoHS directive, - EMC directive and the - Low-voltage directive (LVD) Manufacturer's Statement EU-Regulation regarding the Registration, Evaluation, Authorisation and Restriction of Chemicals Manufacturer's Statement EU-Directive on Waste Electrical and Electronic Equipment RoHS (China RoHS 2) Manufacturer's Statement Administrative Measures for the Restriction of the Use of Hazardous Substances in Electrical and Electronic Products 25 years EAC EAC Certificate EAC EurAsian Conformity - Registration Russia, Kazakhstan and Belarus Jan. 2020 / Rev 0.1 DS-PIM60.245-EN All figures are typical values at 230Vac 50Hz input voltage, 24V 2.5A output load, 25°C ambient temperature and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 Germany 17/20 PRELIMINARY PIM60.245 24V, 2.5A, 60W, SINGLE PHASE INPUT PIANO-Series 20. PHYSICAL DIMENSIONS AND WEIGHT Width Height Depth Weight DIN-Rail Housing material Installation clearances Penetration protection Fig. 20-1 36mm 1.42’’ 90mm 3.54’’ 91mm 3.58’’ The DIN-rail height must be added to the unit depth to calculate the total required installation depth. 220g / 0.49lb Use 35mm DIN-rails according to EN 60715 or EN 50022 with a height of 7.5 or 15mm. High-grade polycarbonate/ ABS blend material See chapter “Installation Instructions” Small parts like screws, nuts, etc. with a diameter larger than 4.2mm. Front view All dimensions in mm Fig. 20-2 Side view All dimensions in mm Jan. 2020 / Rev 0.1 DS-PIM60.245-EN All figures are typical values at 230Vac 50Hz input voltage, 24V 2.5A output load, 25°C ambient temperature and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 Germany 18/20 PRELIMINARY PIM60.245 24V, 2.5A, 60W, SINGLE PHASE INPUT PIANO-Series 21. APPLICATION NOTES 21.1. CHARGING OF BATTERIES Do not use the power supply to charge batteries. 21.2. SERIES OPERATION Unit A Devices of the same type can be connected in series for higher output voltages. It is possible to connect as many units in series as needed, providing the sum of the output voltage does not exceed 150Vdc. Voltages with a potential above 60Vdc must be installed with a protection against touching. Input Output Avoid return voltage (e.g. from a decelerating motor or battery) which is applied to the output terminals. + + Unit B Input Keep an installation clearance of 15mm (left / right) between two power supplies and avoid installing the power supplies on top of each other. Output Pay attention that leakage current, EMI, inrush current, harmonics will increase when using multiple devices. Load - + - 21.3. PARALLEL USE TO INCREASE OUTPUT POWER Do not parallel devices for higher output currents. 21.4. PARALLEL USE FOR 1+1 REDUNDANCY If a 1+1 Redundancy is required, please use the PIM60.246, which has a monitoring (DC OK) function included. ON TWO PHASES The power supply can also be used on two-phases of a three-phase-system. Such a phase-to-phase connection is allowed as long as the supplying voltage is below 240V+10%. Ensure that the wire, which is connected to the N-terminal, is appropriately fused. Power Supply L1 240V +10% max. 21.5. OPERATION L3 L2 Jan. 2020 / Rev 0.1 DS-PIM60.245-EN All figures are typical values at 230Vac 50Hz input voltage, 24V 2.5A output load, 25°C ambient temperature and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 Germany AC L N DC 19/20 PRELIMINARY PIM60.245 24V, 2.5A, 60W, SINGLE PHASE INPUT PIANO-Series 21.6. USE IN A TIGHTLY SEALED ENCLOSURE When the device is installed in a tightly sealed enclosure, the temperature inside the enclosure will be higher than outside. In such situations, the inside temperature defines the ambient temperature for the device. In the following test setup, the device is placed in the middle of the box, no other heat producing items are inside the box. The load is placed outside the box. The temperature sensor inside the box is placed in the middle of the right side of the power supply with a distance of 1cm. The following measurement results can be used as a reference to estimate the temperature rise inside the enclosure. Enclosure size Input voltage Load Temperature inside the box Temperature outside the box Temperature rise Case A 110x180x165mm Rittal Typ IP66 Box PK 9516 100, plastic 230Vac 24V, 2.0A (=80%) 28.6°C 21.0°C 7.6K Case B 110x180x165mm Rittal Typ IP66 Box PK 9516 100, plastic 230Vac 24V, 2.5A; (=100%) 30.2°C 21.0°C 9.2K Jan. 2020 / Rev 0.1 DS-PIM60.245-EN All figures are typical values at 230Vac 50Hz input voltage, 24V 2.5A output load, 25°C ambient temperature and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 Germany 20/20
advertisement