![Puls CD10.242 DC/DC converter Owner's Manual | Manualzz Puls CD10.242 DC/DC converter Owner's Manual | Manualzz](http://s3.manualzz.com/store/data/064994643_1-79e7ac66d85855df3e11b9595ada588f-360x466.png)
CD10.242 DC/DC Converter 48V/24V, 10A, 240W CD-Series DC/DC CONVERTER 48V DC-input Isolated 24Vdc output Efficiency 94% Width only 42mm 20% Output power reserves Full power between -25°C and +60°C Soft-start function Minimal inrush current surge Reverse input polarity protection DC-OK relay contact Current sharing feature for parallel use 3 Year warranty PRODUCT DESCRIPTION SHORT-FORM DATA The CD10.242 is a DIN rail mountable DC/DC converter of the highly reliable DIMENSION series. It provides a floating, stabilized and galvanically separated SELV/PELV output voltage of 24Vdc with 48Vdc on the input. Output voltage Adjustment range Output current The efficiency of 94% and a slim design are cost- and space-saving, while at the same time offering additional power reserves of 20% which may even be used continuously at ambient temperatures up to +45°C. For even higher power needs, multiple devices can be connected in parallel. At any time, a DC-OK LED and a signal contact are informing about the status of the device. A high immunity to transients and power surges as well as low electromagnetic emission makes this DC/DC converter suitable for nearly every situation. Input voltage Input current Input inrush current Efficiency Power losses Hold-up time Temperature range Size (W x H x D) Weight DC 24V Nominal 24 – 28V Factory setting 24.1V 12 – 10.3A Below +45°C ambient 10 – 8.6A At +60°C ambient 7.5 – 6.5A At +70°C ambient Derate between +45°C and +70°C DC 48V ±25% 5.4A 5.8A peak 94% 15.4W 7ms -25°C to +70°C 42x124x117mm Without DIN rail 520g / 1.15lb For 24Vdc/24Vdc or 48Vdc/48Vdc converters, please see PULS products CD10.241 resp. CD10.482. ORDER NUMBERS MAIN APPROVALS For details or a complete approval list, see chapter 19. DC/DC Converter CD10.242 Mechanical Accessory ZM10.WALL Wall/panel mount bracket ZM12.SIDE Side mount bracket UL 61010-1-201 planned IECEx planned ATEX planned Marine planned Jul 2021 / Rev. 0.1 DS-CD10.242-EN All values are typical figures specified at 48Vdc input voltage 24V, 10A output load, 25°C ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 Germany 1/29 CD10.242 DC/DC Converter 48V/24V, 10A, 240W CD-Series INDEX Page 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. Intended Use .......................................................3 Installation Instructions ......................................3 DC-Input...............................................................4 Input Inrush Current ...........................................6 Soft-start Feature ................................................6 Output .................................................................7 Hold-up Time .......................................................8 DC-OK Relay Contact ..........................................9 Efficiency and Power Losses..............................10 Functional Diagram ...........................................11 Front Side and User Elements ...........................11 Terminals and Wiring ........................................12 Lifetime Expectancy ..........................................13 MTBF ..................................................................13 EMC ....................................................................14 Environment ......................................................15 Safety and Protection Features ........................16 Dielectric Strength ............................................17 Page 19. Approved, Fulfilled or Tested Standards ......... 18 20. Regulatory Product Compliance ...................... 19 21. Physical Dimensions and Weight ..................... 20 22. Accessories ........................................................ 21 22.1. ZM10.Wall - Wall/Panel Mount Bracket .. 21 22.2. ZM12.SIDE - Side Mount Bracket ............. 22 22.3. UF20.241 Buffer Module .......................... 23 22.4. YR40.241 - Redundancy Module .............. 23 23. Application Notes ............................................. 24 23.1. Peak Current Capability ........................... 24 23.2. Output Circuit Breakers ............................ 25 23.3. Charging of Batteries ............................... 25 23.4. Series Operation ....................................... 26 23.5. Parallel Use to Increase Output Power .... 26 23.6. Parallel Use for Redundancy .................... 27 23.7. Use in a Tightly Sealed Enclosure ............ 28 23.8. Mounting Orientations ............................ 29 The information given in this document is correct to the best of our knowledge and experience at the time of publication. If not expressly agreed otherwise, this information does not represent a warranty in the legal sense of the word. As the state of our knowledge and experience is constantly changing, the information in this data sheet is subject to revision. We therefore kindly ask you to always use the latest issue of this document (available under www.pulspower.com). No part of this document may be reproduced or utilized in any form without our prior permission in writing. TERMINOLOGY AND ABREVIATIONS PE and symbol PE is the abbreviation for Protective Earth and has the same meaning as the symbol . Earth, Ground This document uses the term “earth” which is the same as the U.S. term “ground”. t.b.d. To be defined, value or description will follow later. DC 48V A figure displayed with the AC or DC before the value represents a nominal voltage with standard tolerances included. E.g.: DC 12V describes a 12V battery disregarding whether it is full (13.7V) or flat (10V) 48Vdc A figure with the unit (Vac) at the end is a momentary figure without any additional tolerances included. may A key word indicating flexibility of choice with no implied preference. shall A key word indicating a mandatory requirement. should A key word indicating flexibility of choice with a strongly preferred implementation. Jul 2021 / Rev. 0.1 DS-CD10.242-EN All values are typical figures specified at 48Vdc input voltage 24V, 10A output load, 25°C ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 Germany 2/29 CD10.242 CD-Series DC/DC Converter 48V/24V, 10A, 240W 1. INTENDED USE This device is designed for installation in an enclosure and is intended for commercial use, such as in industrial control, process control, monitoring, measurement, Audio/Video, information or communication equipment or the like. Do not use this device in equipment, where malfunctioning may cause severe personal injury or threaten human life without additional appropriate safety devices, that are suited for the end-application. If this device is used in a manner outside of its specification, the protection provided by the device may be impaired. 2. INSTALLATION INSTRUCTIONS WARNING - Risk of electrical shock, fire, personal injury or death. Turn power off before working on the device and protect against inadvertent re-powering. Do not open, modify or repair the device. Use caution to prevent any foreign objects from entering into the housing. Do not use in wet locations or in areas where moisture or condensation can be expected. Do not touch during power-on, and immediately after power-off. Hot surface may cause burns. Obey the following installation requirements: This device may only be installed and put into operation by qualified personnel. This device does not contain serviceable parts. The tripping of an internal fuse is caused by an internal defect. If damage or malfunction should occur during installation or operation, immediately turn power off and send unit to the factory for inspection. Install device in an enclosure providing protection against electrical, mechanical and fire hazards. Install the device onto a DIN rail according to EN 60715 with the input terminals on the bottom of the device. Other mounting orientations require a reduction in output current. Make sure that the wiring is correct by following all local and national codes. Use appropriate copper cables that are designed for a minimum operating temperature of 60°C for ambient temperatures up to +45°C, 75°C for ambient temperatures up to +60°C and 90°C for ambient temperatures up to +70°C. Ensure that all strands of a stranded wire enter the terminal connection. Unused screw terminals should be securely tightened. The device is designed for pollution degree 2 areas in controlled environments. No condensation or frost is allowed. The enclosure of the device provides a degree of protection of IP20. The enclosure does not provide protection against spilled liquids. The isolation of the devices is designed to withstand impulse voltages up to 1.5kV according to IEC 60664-1. The input can be powered from batteries or similar DC sources. The voltage between the input terminals and ground must not exceed 60Vdc continuously. The input must be powered from a PELV or SELV source or an "Isolated Secondary Circuit" in order to maintain a SELV or PELV output. Check for correct input polarity. The device will not operate when the voltage is reversed. A disconnecting means shall be provided for the input of the device. The device is designed as “Class of Protection I” equipment according to IEC 61140. Do not use without a proper PE (Protective Earth) connection. The device is designed for convection cooling and does not require an external fan. Do not obstruct airflow and do not cover ventilation grid! The device is designed for altitudes up to 5000m (16400ft). Above 2000m (6560ft) a reduction in output current is required. Keep the following minimum installation clearances: 40mm on top, 20mm on the bottom, 5mm left and right side. Increase the 5mm to 15mm in case the adjacent device is a heat source. When the device is permanently loaded with less than 50%, the 5mm can be reduced to zero. The device is designed, tested and approved for branch circuits up to 50A without additional protection device. If an external fuse is utilized, do not use circuit breakers smaller than 16A B- or C-Characteristic to avoid a nuisance tripping of the circuit breaker. The maximum surrounding air temperature is +70°C (+158°F). The operational temperature is the same as the ambient or surrounding air temperature and is defined 2cm below the device. The device is designed to operate in areas between 5% and 95% relative humidity. Jul 2021 / Rev. 0.1 DS-CD10.242-EN All values are typical figures specified at 48Vdc input voltage 24V, 10A output load, 25°C ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 Germany 3/29 CD10.242 DC/DC Converter 48V/24V, 10A, 240W CD-Series 3. DC-INPUT The input can be powered from batteries or similar DC sources and must be a PELV or SELV source or an "Isolated Secondary Circuit" in order to maintain a SELV or PELV output. Check for correct input polarity. The device will not operate when the voltage is reversed. DC input DC input range Allowed voltage between input and earth/ground Allowed input ripple voltage nom. Turn-on voltage Shut-down voltage Input current typ. typ. typ. typ. typ. typ. max. In the frequency range from 47 to 500Hz, the momentary input voltage must always be within the specified limits. 35Vdc Steady-state value, see Fig. 3-1 32Vdc Steady-state value, see Fig. 3-1 5.4A At 48Vdc input and 24V, 10A output load, see Fig. 3-3 7.5A At 36Vdc input and 24V, 10A output load, see Fig. 3-3 200ms See Fig. 3-1 At 48V, 10A constant current load, 0mF load 150ms capacitance, see Fig. 3-2 At 48V, 10A constant current load, 5mF load 250ms capacitance, see Fig. 3-2 500mV See Fig. 3-2 Installed inside the device, external capacitors on the 1 650µF input are allowed without any limitations. See recommendations in chapter 2. max. typ. Turn-on overshoot Input capacitance max. typ. External input protection Fig. 3-1 Input voltage range Fig. 3-2 Turn-on behavior, definitions Rated input range Turn-on Input Voltage 32.4Vdc 35.0Vdc VIN 17.5Vdc 18.0Vdc 15.5Vdc Shut-down POUT ±25% Continuous operation Continuous operation, according to IEC 62477-1 Output Voltage - 5% Start-up delay Rise Time Overshoot Start-up delay Rise time DC 48V 36-60Vdc 60Vdc or 42.2Vac 10Vpp Fig. 3-3 Input current vs. output load Input Current,typ. 9A t : 36 Inpu 6 Vdc t: 48 Inpu 3 0 2 Vdc 3 4 5 6 7 8 9 10 11 12A Output Current Jul 2021 / Rev. 0.1 DS-CD10.242-EN All values are typical figures specified at 48Vdc input voltage 24V, 10A output load, 25°C ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 Germany 4/29 CD10.242 DC/DC Converter 48V/24V, 10A, 240W CD-Series Requirements for the Supplying Source In certain circumstances, the input filter of the DC/DC converter can show a resonant effect which is caused by the supplying network. Especially when additional external input filters are utilized, a superimposed AC voltage can be generated on the input terminals of the DC/DC converter which might cause a malfunction of the unit. Therefore, additional input filters are not recommended. To avoid the resonant effects, the minimal resistance of the supplying network which depends on the inductance of the input network, shall be above the boundary curve in Fig. 3-4. Fig. 3-4 External input filter requirements to avoid filter instabilities Resistance of the supplying network 1 Ohm 100 mOhm (a) (b) 10 mOhm (a) max. (b) typ. 1 mOhm 0.1mH 1mH 10mH Inductance of the supplying network Jul 2021 / Rev. 0.1 DS-CD10.242-EN All values are typical figures specified at 48Vdc input voltage 24V, 10A output load, 25°C ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 Germany 5/29 CD10.242 DC/DC Converter 48V/24V, 10A, 240W CD-Series 4. INPUT INRUSH CURRENT An active inrush limitation circuit (inrush limiting NTC resistor which is bypassed by a MOSFET) limits the input inrush current after turn-on of the input voltage. The charging current into EMI suppression capacitors is disregarded in the first microseconds after switch-on. Inrush current Inrush energy max. typ typ. max. 8Apeak 7Apeak 5.8Apeak 1A2s At 40°C, cold start At 40°C, cold start At 25°C, cold start At 40°C, cold start Fig. 4-1 Typical input inrush current behavior at nominal load and 25°C ambient 5. SOFT-START FEATURE After the DC/DC converter is turned on, the internal output current rises slowly to its nominal value. This method charges the output capacitors (internal and external capacitors) slowly and avoids high input currents during turn-on. High input currents can produce a high voltage drop on the input wiring (especially with long and thin cables) which reduces the terminal voltage on the DC/DC converter. If the terminal voltage is below the shut-down voltage, the DC/DC converter will turn-off and will make a new start-up attempt. This effect is avoided with the integrated softstart function. Please note that this function increases the rise time of the output voltage by a small amount. Jul 2021 / Rev. 0.1 DS-CD10.242-EN All values are typical figures specified at 48Vdc input voltage 24V, 10A output load, 25°C ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 Germany 6/29 CD10.242 DC/DC Converter 48V/24V, 10A, 240W CD-Series 6. OUTPUT The output provides a SELV/PELV rated voltage, which is galvanically isolated from the input voltage and is designed to supply any kind of loads, including unlimited capacitive and inductive loads. The output is electronically protected against overload, no-load and short-circuits. In case of a protection event, audible noise may occur. Output voltage Adjustment range Factory setting Line regulation Load regulation Ripple and noise voltage Output current Overload behavior Overload/ short-circuit current Output capacitance Back-feeding loads nom. max. 24V 24-28V 30V max. max. 24.1V 25mV 100mV typ. 1000mV max. nom. nom. nom. nom. nom. nom. 100mVpp 12A 10A 7.5A 10.3A 8.6A 6.5A Continuous current 16A 4 500µF 35V max. typ. max. Fig. 6-1 Output voltage vs. output current at 48Vdc input voltage, typ. Guaranteed value from 23-28V This is the maximum output voltage which can occur at the clockwise end position of the potentiometer due to tolerances. It is not a guaranteed value which can be achieved. ±0.2%, at full load, cold unit Between 18 and 35Vdc input voltage variation In “single use” mode: static value, 0A 10A, see Fig. 6-2 In “parallel use” mode: static value, 0A 10A, see Fig. 6-2 Bandwidth 20Hz to 20MHz, 50Ohm At 24V and an ambient temperature below +45°C At 24V and +60° ambient temperature At 24V and +70° ambient temperature At 28V and an ambient temperature below +45° At 28V and +60° ambient temperature At 28V and +70° ambient temperature Continuous current Included inside the power supply The unit is resistant and does not show malfunctioning when a load feeds back voltage to the power supply. It does not matter whether the power supply is on or off. The absorbing energy can be calculated according to the built-in large sized output capacitor. Fig. 6-2 Current limitation vs. input voltage, (46V constant voltage load), typ. Jul 2021 / Rev. 0.1 DS-CD10.242-EN All values are typical figures specified at 48Vdc input voltage 24V, 10A output load, 25°C ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 Germany 7/29 CD10.242 DC/DC Converter 48V/24V, 10A, 240W CD-Series 7. HOLD-UP TIME The input side of the DC/DC converter is equipped with a bulk capacitor which keeps the output voltage alive for a certain period of time when the input voltage dips or is removed. The bulk capacitor can be discharged by loading the DC/DC converter on the output side or through a load which is parallel to the input. There is no protection in the DC/DC converter which prevents current from flowing back to the input terminals. If prevention is needed, an external diode should be used. At no load, the hold-up time can be up to several seconds. The green DC-OK LED is also on during this time. Hold-up Time typ. min. typ. min. 14ms 11ms 7ms 5ms At 24Vdc input voltage, 24V, 5A output, see Fig. 7-1 At 24Vdc input voltage, 24V, 5A output, see Fig. 7-1 At 24Vdc input voltage, 24V, 10A output, see Fig. 7-1 At 24Vdc input voltage, 24V, 10A output, see Fig. 7-1 Fig. 7-1 Hold-up time vs. input voltage Hold-up Time (a) 18ms (a) 24V, 5A, typ. 15 (b) (b) 24V, 5A, min. (c) 24V, 10A, typ. (d) 24V, 10A, min. (c) 12 (d) 9 6 3 Input Voltage 0 36 40 44 48 52 56 60Vdc Fig. 7-2 Shut-down test setup S1 + DC Source - DC/DC Converter Input + Intput Voltage S1 opens + CD10 Output - Fig. 7-3 Shut-down behavior, definitions Load - - 5% Output Voltage Hold-up Time Jul 2021 / Rev. 0.1 DS-CD10.242-EN All values are typical figures specified at 48Vdc input voltage 24V, 10A output load, 25°C ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 Germany 8/29 CD10.242 CD-Series DC/DC Converter 48V/24V, 10A, 240W 8. DC-OK RELAY CONTACT This feature monitors the output voltage on the output terminals. Threshold voltage Contact closes Contact opens Contact ratings Isolation voltage typ. 21V (fixed) As soon as the output voltage reaches 21V. As soon as the output voltage falls below 21V. Maximal 60Vdc 0.3A, 30Vdc 1A, 30Vac 0.5A, resistive load Minimal permissible load 1mA at 5Vdc See dielectric strength table in chapter 18. Fig. 8-1 DC-OK relay contact behavior Jul 2021 / Rev. 0.1 DS-CD10.242-EN All values are typical figures specified at 48Vdc input voltage 24V, 10A output load, 25°C ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 Germany 9/29 CD10.242 DC/DC Converter 48V/24V, 10A, 240W CD-Series 9. EFFICIENCY AND POWER LOSSES Efficiency Average efficiency*) Power losses *) typ. typ. typ. DC 48V 94.0% 93.5% 93.8% typ. typ. typ. typ. 1.2W 7.5W 15.4W 20W At 24V, 10A At 24V, 12A (Power Boost) At 25% at 2.5A, 25% at 5A, 25% at 7.5A. 25% at 10A At no output load At 24V, 5A At 24V, 10A At 24V, 12A The average efficiency is an assumption for a typical application where the power supply is loaded with 25% of the nominal load for 25% of the time, 50% of the nominal load for another 25% of the time, 75% of the nominal load for another 25% of the time and with 100% of the nominal load for the rest of the time. Fig. 9-1 Efficiency vs. output current at 24V, typ. Fig. 9-2 Losses vs. output current at 24V, typ. Fig. 9-3 Efficiency vs. input voltage at 48V, 10A, typ. Fig. 9-4 Losses vs. input voltage at 48V, 10A, typ. Efficiency 94.5% 94.0 93.5 93.0 92.5 92.0 36 40 44 48 52 56 60Vdc Input Voltage Jul 2021 / Rev. 0.1 DS-CD10.242-EN All values are typical figures specified at 48Vdc input voltage 24V, 10A output load, 25°C ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 Germany 10/29 CD10.242 DC/DC Converter 48V/24V, 10A, 240W CD-Series 10. FUNCTIONAL DIAGRAM Fig. 10-1 Functional diagram Link for Parallel Use Output Voltage Regulator VOUT + PE Input Fuse & Input Filter Reverse Polarity Protection & Inrush Limiter Output OverVoltage Protection Power Converter Output Voltage Monitor Output Filter DC OK Relay + DC Ok Contact DC Ok LED 11. FRONT SIDE AND USER ELEMENTS Fig. 11-1 Front side A B1 B2 C D E Input terminals + Positive input - Negative input PE --> Protective Earth (Ground) connection Output terminals Single terminal for the positive pole and dual terminals for the negative pole. Both negative poles are internally connected. + Positive output - Negative (return) output DC-OK relay contact The DC-OK relay contact is synchronized with the DC-OK LED. See chapter 8 for details. Output voltage potentiometer DC-OK LED (green) The LED is on, when the output voltage is above 21V. “Parallel Use” “Single Use” link Link the two terminal poles when outputs of devices are connected in parallel. In order to achieve a sharing of the load current between the individual devices, the “parallel use” regulates the output voltage in such a manner that the voltage at no load is approx. higher than at nominal load. See chapter 23.5 for details. Jul 2021 / Rev. 0.1 DS-CD10.242-EN All values are typical figures specified at 48Vdc input voltage 24V, 10A output load, 25°C ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 Germany 11/29 CD10.242 DC/DC Converter 48V/24V, 10A, 240W CD-Series 12. TERMINALS AND WIRING The terminals are IP20 Finger safe constructed and suitable for field- and factory wiring. Input Screw terminals max. 6mm2 max. 4mm2 20-10 AWG 2.8mm 1Nm, 9lb.in 7mm / 0.28inch 3.5mm slotted or Phillips No 1 Type Solid wire Stranded wire American Wire Gauge Max. wire diameter (including ferrules) Recommended tightening torque Wire stripping length Screwdriver Output Screw terminals max. 6mm2 max. 4mm2 20-10 AWG 2.8mm 1Nm, 9lb.in 7mm / 0.28inch 3.5mm slotted or Phillips No 1 Daisy chaining of outputs: Daisy chaining (jumping from one DC/DC-converter output to the next) is allowed as long as the average output current through one terminal pin does not exceed 25A. If the current is higher, use a separate distribution terminal block. Fig. 12-1 Daisy chaining of outputs Fig. 12-2 Using distribution terminals max 25A! Output + + - - Output + + - - + - Load Output + + - - Output + + - - DC/DC Converter DC/DC Converter DC/DC Converter DC/DC Converter Input Input Input Input + Distribution Terminals Jul 2021 / Rev. 0.1 DS-CD10.242-EN All values are typical figures specified at 48Vdc input voltage 24V, 10A output load, 25°C ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 Germany - Load 12/29 CD10.242 DC/DC Converter 48V/24V, 10A, 240W CD-Series 13. LIFETIME EXPECTANCY The Lifetime expectancy shown in the table indicates the minimum operating hours (service life) and is determined by the lifetime expectancy of the built-in electrolytic capacitors. Lifetime expectancy is specified in operational hours and is calculated according to the capacitor’s manufacturer specification. The manufacturer of the electrolytic capacitors only guarantees a maximum life of up to 15 years (131 400h). Any number exceeding this value is a calculated theoretical lifetime which can be used to compare devices. Lifetime expectancy Input 48Vdc 275 000h 117 000h 70 000h 788 000h 327 000h 197 000h At 24V, 5A and 40°C At 24V, 10A and 40°C At 24V, 12A and 40°C At 24V, 5A and 25°C At 24V, 10A and 25°C At 24V, 12A and 25°C 14. MTBF MTBF stands for Mean Time Between Failure, which is calculated according to statistical device failures, and indicates reliability of a device. It is the statistical representation of the likelihood of a unit to fail and does not necessarily represent the life of a product. The MTBF figure is a statistical representation of the likelihood of a device to fail. A MTBF figure of e.g. 1 000 000h means that statistically one unit will fail every 100 hours if 10 000 units are installed in the field. However, it cannot be determined if the failed unit has been running for 50 000h or only for 100h. For these types of units the MTTF (Mean Time To Failure) value is the same value as the MTBF value. MTBF SN 29500, IEC 61709 MTBF MIL HDBK 217F Input 48Vdc t.b.d. t.b.d. t.b.d. t.b.d. t.b.d. t.b.d. At 24V, 10A and 40°C At 24V, 10A and 25°C At 10A and 40°C; Ground Benign GB40 At 10A and 25°C; Ground Benign GB25 At 10A and 40°C; Ground Fixed GF40 At 10A and 25°C; Ground Fixed GF25 Jul 2021 / Rev. 0.1 DS-CD10.242-EN All values are typical figures specified at 48Vdc input voltage 24V, 10A output load, 25°C ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 Germany 13/29 CD10.242 DC/DC Converter 48V/24V, 10A, 240W CD-Series 15. EMC The EMC behavior of the device is designed for applications in industrial environment as well as in residential, commercial and light industry environments. The device is investigated according to the generic standards EN 61000-6-1, EN 61000-6-2, EN 61000-6-3 and EN 610006-4. Without additional measures to reduce the conducted emissions on the output (e.g. by using a filter), the device is not suited to supply a local DC power network in residential, commercial and light-industrial environments. No restrictions apply for local DC power networks in industrial environments. EMC Immunity Electrostatic discharge Power lines and housing Contact discharge EN 61000-4-2 Air discharge EN 61000-4-3 80MHz-2.7GHz 2.7GHz-6.0GHz Input lines EN 61000-4-4 Output lines EN 61000-4-5 ++/- chassis ground +EN 61000-4-5 + / - chassis ground EN 61000-4-6 0.15-80MHz 8kV 15kV 20V/m 10V/m 4kV 2kV 1kV 2kV 500V 1kV 20V Criterion A Criterion A Criterion A Criterion A Criterion A Criterion A Criterion A Criterion A Criterion A Criterion A Criterion A DC-OK signal lines EN 61000-4-3 80MHz-2.7GHz 2.7GHz-6.0GHz EN 61000-4-4 DC-OK lines with coupling clamp 20V/m 10V/m Criterion A Criterion A 2kV Criterion A Surge EN 61000-4-5 DC-OK lines chassis ground 1kV Criterion A Conducted disturbance EN 61000-4-6 0.15-80MHz 20V Criterion A Electromagnetic RF field Fast transients (Burst) Surge voltage on input Surge voltage on output Conducted disturbance EMC Immunity Electromagnetic RF field Fast transients (Burst) Criterions: A: The device shows normal operation behavior within the defined limits. C: Temporary loss of function is possible. The device may shut down and restarts by itself. No damage or hazards for the device will occur. EMC Emission Conducted emission on input lines Limits for DC power networks according to EN 61000-6-3 fulfilled Limits for DC power networks according IEC 61000-6-4 fulfilled IEC/CISPR 16-1-2, IEC/CISPR 16-2-1 Conducted emission on IEC/CISPR 16-1-2, IEC/CISPR 16-2-1 output lines Radiated emission EN 55011, EN 55032 Class B This device complies with FCC Part 15 rules. Operation is subjected to following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Switching Frequency Main converter 75kHz to 500kHz Output load and input voltage dependent Jul 2021 / Rev. 0.1 DS-CD10.242-EN All values are typical figures specified at 48Vdc input voltage 24V, 10A output load, 25°C ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 Germany 14/29 CD10.242 DC/DC Converter 48V/24V, 10A, 240W CD-Series 16. ENVIRONMENT The operational temperature is the ambient or surrounding temperature and is defined as the air temperature 2cm below the device. -40°C to +85°C (-40°F to 185°F) For storage and transportation 3.2W/°C Between +45°C and +60°C (113°F to 140°F) 6W/°C Between +60°C and +70°C (140°F to 158°F) 15W/1000m or 5°C/1000m For altitudes >2000m (6560ft), see Fig. 15-2 For atmospheric pressures <80kPa, see Fig. 15-2 9W/-5kPa or 3°C/-5kPa The de-rating is not hardware controlled. The customer has to take care by himself to stay below the de-rated current limits in order not to overload the unit. 5 to 95% r.h. According to IEC 60068-2-30 110-47kPa See Fig. 15-2 for details Up to 5000m (16 400ft) See Fig. 15-2 for details 2 According to IEC 62477-1, not conductive 2-17.8Hz: ±1.6mm; 17.8-500Hz: 2g According to IEC 60068-2-6 2 hours / axis 30g 6ms, 20g 11ms According to IEC 60068-2-27 3 bumps / direction, 18 bumps in total Shock and vibration is tested in combination with DIN rails according to EN 60715 with a height of 15mm and a thickness of 1.3mm and standard orientation. Some audible noise may be emitted from the power supply during no load, overload or short circuit. Operational temperature -25°C to +70°C (-13°F to 158°F) Storage temperature Output de-rating Humidity Atmospheric pressure Altitude Degree of pollution Vibration sinusoidal Shock Audible noise Fig. 16-1 Output current vs. ambient temp. Allowed Output Current at 24V 12A 12A B A 10A A... Continuous B... Short term 6A 4A 0 -25 C B 10A A 8A 8A 2A Fig. 16-2 Output current vs. altitude at 48V Allowed Output Current at 24V 6A 4A 2A Ambient Temperature 0 20 40 60 70°C A... Ambient < 60°C B... Ambient < 45°C C... Short term Altitude 0m AP*) 110kPa 2000m 80kPa *) Atmospheric pressure 4000m 62kPa 6000m 47kPa Jul 2021 / Rev. 0.1 DS-CD10.242-EN All values are typical figures specified at 48Vdc input voltage 24V, 10A output load, 25°C ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 Germany 15/29 CD10.242 DC/DC Converter 48V/24V, 10A, 240W CD-Series 17. SAFETY AND PROTECTION FEATURES Isolation resistance min. 500MOhm min. 500MOhm min. 500MOhm min. 500MOhm PE resistance max. 0.1Ohm Output over-voltage protection typ. max. Class of protection Degree of protection Over-temperature protection Input transient protection Internal input fuse Touch current (leakage current) At delivered condition between input and output, measured with 500Vdc At delivered condition between input and Chassis Ground, measured with 500Vdc At delivered condition between output and Chassis Ground, measured with 500Vdc At delivered condition between output and DC-OK contacts, measured with 500Vdc Resistance between PE terminal and the housing in the area of the DIN rail mounting bracket. 31Vdc 32.5Vdc In case of an internal defect, a redundant circuit limits the maximum output voltage. The output shuts down and automatically attempts to restart. I According to IEC 61140 IP 20 According to EN/IEC 60529 Not included MOV (Metal For protection values see chapter 15 (EMC). Oxide Varistor) Not user replaceable slow-blow high-braking Included capacity fuse The leakage current, which is produced by the DC/DC converter itself, depends on the input voltage ripple and need to be investigated in the final application. For a smooth DC input voltage, the produced leakage current is less than 100µA. Jul 2021 / Rev. 0.1 DS-CD10.242-EN All values are typical figures specified at 48Vdc input voltage 24V, 10A output load, 25°C ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 Germany 16/29 CD10.242 DC/DC Converter 48V/24V, 10A, 240W CD-Series 18. DIELECTRIC STRENGTH The output voltage is floating and has no ohmic connection to the ground. The output is insulated to the input by a double or reinforced insulation. Type and routine tests are conducted by the manufacturer. Field tests may be conducted in the field using the appropriate test equipment which applies the voltage with a slow ramp (2s up and 2s down). Connect all inputterminals together as well as all output poles before conducting the test. When testing, set the cut-off current settings to the value in the table below. We recommend that either the (+) pole or the (-) pole shall be connected to the protective earth system. This helps to avoid situations in which a load starts unexpectedly or cannot be switched off when unnoticed earth faults occur. Type test 60s A 1500Vac B 1500Vac C 500Vac D 500Vac Routine test 5s 1500Vac 1500Vac 500Vac 500Vac Field test 5s 1000Vac 1000Vac 500Vac 500Vac >20mA >10mA >12mA >1mA Fig. 18-1 Dielectric strength Field test cut-off current setting B*) When testing input to DC-OK ensure that the maximal voltage between DC-OK and the output is not exceeded (column D). We recommend connecting DC-OK pins and the output pins together when performing the test. Jul 2021 / Rev. 0.1 DS-CD10.242-EN All values are typical figures specified at 48Vdc input voltage 24V, 10A output load, 25°C ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 Germany 17/29 CD10.242 CD-Series DC/DC Converter 48V/24V, 10A, 240W 19. APPROVED, FULFILLED OR TESTED STANDARDS UL 61010 planned IEC 61010 planned ATEX planned IECEx planned Marine (DNV) planned ISA-71.04-1985 VDMA 24364 UL Certificate Listed equipment for category NMTR - UL 61010-2-201 Electrical Equipment for Measurement, Control and Laboratory Use Particular requirements for control equipment Applicable for US and Canada E-File: E198865 CB Scheme Certificate IEC 61010-2-201 Electrical Equipment for Measurement, Control and Laboratory Use - Particular requirements for control equipment Agency Certificate (Bureau Veritas) EN 60079-0 Explosive atmospheres - General requirements EN 60079-7, EN 60079-15 Equipment protection by type of protection "e" and "n" Certificate: t.b.d. Temperature Code: t.b.d. Type of Protection: t.b.d. IECEx Certificate IEC 60079-0 Explosive atmospheres - General requirements IEC 60079-7, IEC 60079-15 Equipment protection by type of protection "e" and "n" Certificate: t.b.d. Temperature Code: t.b.d. Type of Protection: t.b.d. DNV Certificate DNV Type approved product Certificate: t.b.d. Temperature: t.b.d. Humidity: t.b.d. Vibration: t.b.d. EMC: t.b.d. Enclosure: t.b.d. Manufacturer's Declaration (Online Document) Airborne Contaminants Corrosion Test Severity Level: G3 Harsh H2S: 100ppb NOx: 1250ppb Cl2: 20ppb SO2: 300ppb Test Duration: 3 weeks, which simulates a service life of at least 10 years Paint Wetting Impairment Substances Test (or LABS-Test) Tested for Zone 2 and test class C1 according to VDMA 24364-C1L/W for solvents and water-based paints Jul 2021 / Rev. 0.1 DS-CD10.242-EN All values are typical figures specified at 48Vdc input voltage 24V, 10A output load, 25°C ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 Germany 18/29 CD10.242 DC/DC Converter 48V/24V, 10A, 240W CD-Series 20. REGULATORY PRODUCT COMPLIANCE EU Declaration of Conformity REACH Directive EAC TR Registration The CE mark indicates conformance with the - EMC directive - RoHS directive Manufacturer's Statement EU-Directive regarding the Registration, Evaluation, Authorization and Restriction of Chemicals EAC Certificate EAC EurAsian Conformity - Registration Russia, Kazakhstan and Belarus 8504408200, 8504409000 Jul 2021 / Rev. 0.1 DS-CD10.242-EN All values are typical figures specified at 48Vdc input voltage 24V, 10A output load, 25°C ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 Germany 19/29 CD10.242 CD-Series DC/DC Converter 48V/24V, 10A, 240W 21. PHYSICAL DIMENSIONS AND WEIGHT Width Height Depth Weight DIN rail Housing material Installation clearances Penetration protection 42mm 1.65’’ 124mm 4.88’’ 117mm 4.61’’ The DIN rail height must be added to the unit depth to calculate the total required installation depth. 520g / 1.15lb Use 35mm DIN rails according to EN 60715 or EN 50022 with a height of 7.5 or 15mm. Body: Aluminium alloy Cover: zinc-plated steel See chapter 2 Small parts like screws, nuts, etc. with a diameter larger than 3.5mm Fig. 21-1 Front view Fig. 21-2 Side view All dimensions in mm All dimensions in mm Jul 2021 / Rev. 0.1 DS-CD10.242-EN All values are typical figures specified at 48Vdc input voltage 24V, 10A output load, 25°C ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 Germany 20/29 CD10.242 CD-Series DC/DC Converter 48V/24V, 10A, 240W 22. ACCESSORIES 22.1. ZM10.WALL - WALL/PANEL MOUNT BRACKET This bracket is used to mount the devices on a wall/panel without utilizing the DIN rail. The bracket can be mounted without detaching the DIN rail brackets from the power supply. Fig. 22-1 Isometric view Fig. 22-2 Isometric view Fig. 22-3 Isometric view Fig. 21 4 Wall/panel mounting, front view Fig. 21 5 Hole pattern for wall mounting Fig. 22-4 Wall/panel mounting, side view All dimensions in mm All dimensions in mm All dimensions in mm Jul 2021 / Rev. 0.1 DS-CD10.242-EN All values are typical figures specified at 48Vdc input voltage 24V, 10A output load, 25°C ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 Germany 21/29 CD10.242 DC/DC Converter 48V/24V, 10A, 240W CD-Series 22.2. ZM12.SIDE - SIDE MOUNT BRACKET This ZM12.SIDE bracket is used to mount the device sideways with or without utilizing a DIN rail to save installation depth. The two aluminum brackets and the black plastic slider of the unit have to be detached, so that the ZM12.SIDE steel bracket can be mounted. For sideway DIN rail mounting, the removed aluminum brackets and the black plastic slider need to be mounted on the ZM12.SIDE steel bracket. PSU for illustration purpose only. Fig. 22-5 Side mounting without DIN rail brackets Fig. 22-6 Side mounting with DIN rail brackets Fig. 22-7 Hole pattern All dimensions in mm Jul 2021 / Rev. 0.1 DS-CD10.242-EN All values are typical figures specified at 48Vdc input voltage 24V, 10A output load, 25°C ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 Germany 22/29 CD10.242 CD-Series DC/DC Converter 48V/24V, 10A, 240W 22.3. UF20.241 BUFFER MODULE The UF20.241 buffer module is a supplementary device for 24V DC/DC converters. It delivers power to bridge typical supply voltage faults or extends the hold-up time after the input power is turned off. When the DC/DC converter provides a sufficient voltage, the buffer module stores energy in the integrated electrolytic capacitors. When the input voltage is lost, the stored energy is released to the DC-bus in a regulated process. The buffer module can be added in parallel to the load circuit at any given point and does not require any control wiring. One buffer module can deliver 20A additional current and can be added in parallel to increase the output ampacity or the hold-up time. For longer hold-up times the UF40.241 might also be an option. 22.4. YR40.241 - REDUNDANCY MODULE The YR40.241 is a dual redundancy module, which can be used to build 1+1 or N+1 redundant systems. The device is equipped with two 20A nominal input channels, which are individually decoupled by utilizing MOSFET technology. The output can be loaded with a nominal 40A continuous current. Using MOSFETSs instead of diodes reduces heat generation, losses and voltage drop between input and output. Due to these advantages, the unit is very narrow and only requires 36mm width on the DIN rail. The device does not require an additional auxiliary voltage and is self-powered even in case of a short circuit across the output. A feature of this redundancy module is a special circuit, which keeps the losses and temperature low, even at overload and short circuit conditions up to 65A continuous current. See chapter 12 for wiring information. Jul 2021 / Rev. 0.1 DS-CD10.242-EN All values are typical figures specified at 48Vdc input voltage 24V, 10A output load, 25°C ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 Germany 23/29 CD10.242 DC/DC Converter 48V/24V, 10A, 240W CD-Series 23. APPLICATION NOTES 23.1. PEAK CURRENT CAPABILITY The unit can deliver peak currents (up to several milliseconds) which are higher than the specified short term currents. This helps to start current demanding loads. Solenoids, contactors and pneumatic modules often have a steady state coil and a pick-up coil. The inrush current demand of the pick-up coil is several times higher than the steady-state current and usually exceeds the nominal output current. The same situation applies when starting a capacitive load. The peak current capability also ensures the safe operation of subsequent circuit breakers of load circuits. The load branches are often individually protected with circuit breakers or fuses. In case of a short or an overload in one branch circuit, the fuse or circuit breaker need a certain amount of over-current to open in a timely manner. This avoids voltage loss in adjacent circuits. The extra current (peak current) is supplied by the power converter and the built-in large sized output capacitors of the power supply. The capacitors get discharged during such an event, which causes a voltage dip on the output. The following two examples show typical voltage dips: Fig. 23-1 20A Resistive peak load (2x the nominal current) for 50ms, typ. Peak current voltage dips typ. typ. typ. from 24V to 14V from 24V to 12V from 24V to 6V Fig. 23-2 50A Resistive peak load (5x the nominal current) for 5ms, typ. at 20A for 50ms, resistive load at 40A for 2ms, resistive load at 40A for 5ms, resistive load Jul 2021 / Rev. 0.1 DS-CD10.242-EN All values are typical figures specified at 48Vdc input voltage 24V, 10A output load, 25°C ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 Germany 24/29 CD10.242 DC/DC Converter 48V/24V, 10A, 240W CD-Series 23.2. OUTPUT CIRCUIT BREAKERS Standard miniature circuit breakers (MCBs) are commonly used for AC supply systems, but can also be used in DC branches if specified. Such MCBs are designed to protect wires and circuits. When the ampere rating and characteristics of the MCB are matched to the wire size used, the wiring is considered thermally safe whether the MCB opens or not. To avoid voltage dips and undervoltage situations in adjacent DC branches fed by the same source, fast (magnetic) tripping of the MCB is desirable. For example, a fast trip within 10ms avoids a shutdown and restart of the PLC. For this purpose, power supplies with high current reserves and large output capacitors are advantageous. In addition, the impedance of the faulty circuit must be sufficiently small so that the current can actually flow. The best current reserves of a power supply are of no help if Ohm's law does not allow the current to flow. The following table provides typical test results showing which MCBs magnetically trip as a function of wire size and length. The lengths given correspond to the total length, which is the sum of the outgoing (+) and return (-) wire. The tests were performed without additional load. Fig. 23-3 Test circuit for maximum wire length DC/DC Converter DC MCB Load + + Wire length S1 - DC S1... Fault simulation switch Test results for maximum wire length: C-2A C-3A C-4A C-6A C-8A B-6A B-10A 0.75mm² 23m 14m 8m 2m 0m 11m 2m 1.0mm² 32m 18m 9m 2m 1m 13m 2m 1.5mm² 43m 26m 14m 4m 1m 21m 4m 2.5mm² 62m 39m 18m 6m 1m 29m 4m B-13A 1m 1m 1m 2m 23.3. CHARGING OF BATTERIES The device can be used to charge lead-acid or maintenance free batteries. Four 12V SLA or VLRA batteries are needed in series connection. Instructions for charging batteries: a) Ensure that the ambient temperature of the Device is below 45°C. b) Set output voltage, measured at no load and at the battery end of the cable, very precisely to the end-of-charge voltage. End-of-charge voltage 27.8V 27.5V 27.15V 26.8V Battery temperature 10°C 20°C 30°C 40°C c) Use a 16A circuit breaker or blocking diode between the Device and the battery. d) Ensure that the output current of the Device is below the allowed charging current of the battery. e) Use only matched batteries when putting 12V types in series. f) The return current to the device (battery discharge current) is typ. 10mA when the Device is switched off except in case a blocking diode is utilized. g) Do not use the devices for battery charging in mounting orientations other than the standard mounting orientation or in any other condition where a reduction of the output current is required (e.g. altitude). Jul 2021 / Rev. 0.1 DS-CD10.242-EN All values are typical figures specified at 48Vdc input voltage 24V, 10A output load, 25°C ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 Germany 25/29 CD10.242 CD-Series DC/DC Converter 48V/24V, 10A, 240W 23.4. SERIES OPERATION Unit A Devices of the same type can be connected in series for higher output voltages. It is possible to connect as many units in series as needed, providing the sum of the output voltage does not exceed 150Vdc. Voltages with a potential above 60Vdc must be installed with a protection against touching. Avoid return voltage (e.g. from a decelerating motor or battery) which is applied to the output terminals. Input Output Unit B Input Keep an installation clearance of 15mm (left / right) between two power supplies and avoid installing the power supplies on top of each other. Do not use power supplies in series in mounting orientations other than the standard mounting orientation. Output + Load - + + - - Pay attention that EMI and inrush current will increase when using multiple devices. 23.5. PARALLEL USE TO INCREASE OUTPUT POWER Unit A Devices can be paralleled to increase the output power. The output voltage of all power supplies shall be adjusted to the same value (±100mV) in “Single Use” mode with the same load conditions on all units, or the units can be left with the factory settings. After the adjustments, set the unit to “Parallel Use” mode, in order to achieve load sharing. The “Parallel Use” mode regulates the output voltage in such a manner that the voltage at no load is approx. 4% higher than at nominal load. See also chapter 6. Input Output Unit B Input The ambient temperature is not allowed to exceed +60°C. + - Load + + - Output If more than three devices are connected in parallel, a diode, fuse or circuit breaker with a rating of 15A or 16A is required on each output. Alternatively, a diode or redundancy module can also be utilized. Keep an installation clearance of 15mm (left / right) between two devices and avoid installing devices on top of each other. Do not use devices in parallel in mounting orientations other than the standard mounting orientation or in any other condition where a reduction of the output current is required (e.g. altitude). Pay attention that leakage current, EMI, inrush current will increase when using multiple devices. Jul 2021 / Rev. 0.1 DS-CD10.242-EN All values are typical figures specified at 48Vdc input voltage 24V, 10A output load, 25°C ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 Germany 26/29 CD10.242 DC/DC Converter 48V/24V, 10A, 240W CD-Series 23.6. PARALLEL USE FOR REDUNDANCY 1+1 Redundancy: Devices can be paralleled for redundancy to gain higher system availability. Redundant systems require a certain amount of extra power to support the load in case one device fails. The simplest way is to put two devices in parallel. This is called a 1+1 redundancy. In case one device fails, the other one is automatically able to support the load current without any interruption. It is essential to use a redundancy module to decouple devices from each other. This prevents that the defective unit becomes a load for the other device and the output voltage cannot be maintained any more. 1+1 redundancy allows ambient temperatures up to +70°C. Pay attention that EMI and inrush current will increase when using multiple devices. Recommendations for building redundant power systems: - Use separate input fuses for each device. - Use separate supply systems for each device whenever it is possible. - It is desirable to set the output voltages of all devices to the same value (± 100mV) or leave it at the factory setting. N+1 Redundancy: Redundant systems for a higher power demand are usually built in a N+1 method. E.g. four devices, each rated for 10A are paralleled to build a 30A redundant system. Pay attention that EMI and inrush current will increase when using multiple devices. Keep an installation clearance of 15mm (left / right) between two devices and avoid installing the devices on top of each other. Do not use devices in parallel in mounting orientations other than the standard mounting orientation or in any other condition, where a reduction of the output current is required. For N+1 redundancy the ambient temperature is not allowed to exceed +45°C. Wiring examples for 1+1 and n+1 redundancy: Fig. 23-4 1+1 Redundant configuration for 10A load current Fig. 23-5 N+1 Redundant configuration for 30A load current with multiple DC/DC converters and redundancy modules Jul 2021 / Rev. 0.1 DS-CD10.242-EN All values are typical figures specified at 48Vdc input voltage 24V, 10A output load, 25°C ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 Germany 27/29 CD10.242 DC/DC Converter 48V/24V, 10A, 240W CD-Series 23.7. USE IN A TIGHTLY SEALED ENCLOSURE When the DC/DC Converter is installed in a tightly sealed enclosure, the temperature inside the enclosure will be higher than outside. In such situations, the inside temperature defines the ambient temperature for the DC/DC Converter. The following measurement results can be used as a reference to estimate the temperature rise inside the enclosure. The DC/DC Converter is placed in the middle of the box, no other heat producing items are inside the box. The temperature sensor inside the box is placed in the middle of the right side of the DC/DC Converter with a distance of 1cm. Enclosure size Input voltage Load Temperature inside the box Temperature outside the box Temperature rise Case A 110x180x165mm Rittal Typ IP66 Box PK 9516 100, plastic 48Vdc 24V, 8A; (=80%) 45.4°C 21.0°C 24.4K Case B 110x180x165mm Rittal Typ IP66 Box PK 9516 100, plastic 48Vdc 24V, 10A; (=100%) 52.4°C 21.0°C 31.4K Jul 2021 / Rev. 0.1 DS-CD10.242-EN All values are typical figures specified at 48Vdc input voltage 24V, 10A output load, 25°C ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 Germany 28/29 CD10.242 DC/DC Converter 48V/24V, 10A, 240W CD-Series 23.8. MOUNTING ORIENTATIONS Mounting orientations other than input terminals on the bottom and output on the top require a reduction in continuous output power or a limitation in the maximum allowed ambient temperature. The listed lifetime and MTBF values from this datasheet apply only for the standard mounting orientation. The following curves give an indication for allowed output currents for altitudes up to 2000m (6560ft). Fig. 23-6 Mounting Orientation A (Standard orientation) Allowed Output Current at 24V OUTPUT 12A 10A DC/DC Converter 7.5A 0 INPUT +45 +60 +70°C Ambient Temperature Fig. 23-7 Mounting Orientation B (Upside down) Allowed Output Current at 24V 12A INPUT 7.5A DC/DC Converter 0 OUTPUT Fig. 23-8 Mounting Orientation C (Table-top mounting) 12A 6.5A +25 +60 +70°C Ambient Temperature Allowed Output Current at 24V 12A OUTPUT DC/DC Converter INPUT 6.5A 0 +25 +60 +70°C Ambient Temperature Allowed Output Current at 24V INPUT DC/DC Converter 12A OUTPUT Fig. 23-10 Mounting Orientation E (Horizontal ccw) +60 +70°C Ambient Temperature Allowed Output Current at 24V 0 Fig. 23-9 Mounting Orientation D (Horizontal cw) +30 6.5A 0 +25 +60 +70°C Ambient Temperature Jul 2021 / Rev. 0.1 DS-CD10.242-EN All values are typical figures specified at 48Vdc input voltage 24V, 10A output load, 25°C ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 Germany 29/29
advertisement