Model #: SMART750RMXL2U

SmartPro .75kVA Line Interactive Sine Wave UPS, Extended-run & SNMPWEBCARD options, 2U Rack/Tower,

USB, Serial, EPO, 120V

Highlights

750VA line interactive 2U rack/tower UPS; Sine wave output

120V nominal output during brownouts to 83V and overvoltages to 147V

USB, RS232, EPO and optional SNMP/Web card are available for simultaneous use

Expandable runtime, Status LEDs; 2 switched output load banks

NEMA 5-15P input; 6 NEMA 5-15R outlets

Description

Tripp Lite's SMART750RMXL2U intelligent, line interactive rack/tower uninterruptible power supply prevents data loss, downtime and equipment damage due to power outages, voltage fluctuations and transient surges. Requires only two rack spaces (2U) in a standard rack enclosure. Large internal batteries offer 30 minutes half load runtime and 12.5 minutes at full load. Extended runtime available with optional BP24V15RT2U,

BP24V28-2U (limit of one per UPS) or BP24V70-3U (multi-pack compatible) external battery packs. Maintains regulated 120V nominal output without using battery power during brownouts and overvoltages from 83 to 147V. 750VA/450 watt power handling capability supports a variety of networking, telecom and other sensitive electronic applications. Includes a total of 6 outlets arranged in 2 load banks that are individually controllable via software interface to reboot select equipment on demand or shed less significant loads to extend battery runtime for more critical equipment.

Supports remote monitoring of UPS and site power conditions via built-in USB and DB9 monitoring ports. Includes PowerAlert UPS monitoring and unattended shutdown software with complete cabling. Built-in accessory slot supports SNMP with optional SNMPWEBCARD adapter. Emergency

Power Off (EPO) interface offers option for instantaneous power-off of UPS and connected equipment in the case of fire or emergency.

Multi-function audible alarms and set of 5 front panel LEDs offer at-a-glance notification of UPS and line power status. Network-grade AC surge suppression protects equipment from damage and performance problems resulting from transient surges and line noise. Attractive all-black color scheme.

Package Includes

SMART750RMXL2U UPS System

PowerAlert software with USB and DB9 cables

Mounting hardware for 4 post rackmount installation

Cable for Emergency Power Off interface

Instruction manual

Features

SMART750RMXL2U line interactive UPS offers voltage regulation and battery support, plus complete AC surge suppression

Supports 2U rackmount and upright tower applications (2-9USTAND accessory sold separately)

Full time sine wave output offers guaranteed compatibility with all equipment types

Supports a max load of 750VA for 12.5 minutes and a half load of 375VA for 30 minutes

Extended runtime available with optional BP24V15RT2U, BP24V28-2U (limit of one per UPS) or BP24V70-3U (multi-pack compatible) external battery packs

Maintains regulated 120V nominal output 83 to 147V

750VA/450 watt power handling capability supports a variety of sensitive electronic loads

Includes 6 UPS supported outlets arranged in 2 individually controllable load banks

Built in USB and DB9 serial ports support remote monitoring of UPS and site power conditions

Built in accessory slot supports SNMP with optional SNMPWEBCARD adapter

Emergency Power Off (EPO) interface with cable

Multi-function audible alarms and set of 5 front panel LEDs

Network-grade AC surge suppression

Attractive all-black color scheme

UPS battery set ships fully assembled and ready for installation, no time consuming connection of internal batteries by user is necessary

Mounting hardware included for 4 post rackmount enclosures, 2 post telecom rack compatible with separate purchase 2POSTRMKITWM, compatible with upright tower installation with included hardware

Specifications

OUTPUT

Output Volt Amp Capacity

(VA)

Output Watt Capacity

(watts)

Output power factor

Nominal Output Voltage(s)

Supported

Frequency compatibility

Output voltage regulation

(line mode)

Output voltage regulation

(Battery mode)

Built-in UPS output receptacles

Built-in controllable switched load banks

Output AC waveform (AC mode)

Output AC waveform

(battery mode)

INPUT

Rated input current (at maximum load)

Nominal Input Voltage(s)

Supported

UPS input connection type

Input circuit breaker

UPS Input cord length (ft.)

UPS Input cord length (m)

Recommended Electrical

Service

Input cord length (ft.)

Input cord length (m)

BATTERY

Full load runtime (minutes)

750

450

0.6

120V

60 Hz

-21%, +8%

+/- 5%

6 5-15R outlet(s)

Two switchable two-outlet 5-15R load banks

Sine wave

Pure Sine wave

6.8A

120V AC

5-15P

15A

10 ft / 3m

3.05

15A 120V

10

3

12.5 min. (450w)

Half load runtime (minutes) 30 min. (225w)

Expandable battery runtime Extended runtime supported via optional external battery packs

External battery pack compatibility

BP24V15RT2U (limit 1); BP24V28-2U (limit 1); BP24V70-3U (multi-pack compatible)

DC system voltage (VDC)

Battery recharge rate

(included batteries)

Replacement battery cartridge (internal UPS battery replacement)

24

Less than 4 hours from 10% to 90%

RBC92-2U

Battery Access

Battery replacement description

VOLTAGE REGULATION

Voltage regulation description

Front panel battery access door

Hot-swappable, user replaceable batteries

Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 83 to 147

Overvoltage correction Input voltages between 128 and 147 are reduced by 12%

Undervoltage correction

LEDS ALARMS & SWITCHES

Input voltages between 83 and 107 are boosted by 14%

LED Indicators 5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status

Alarms

Alarm cancel operation

Audible alarm indicates power-failure, overload and low-battery conditions

Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate low-battery status

Switches

SURGE / NOISE SUPPRESSION

2 Switches control off/on power status and alarm-cancel/self-test operation

UPS AC suppression joule rating

480 joules

EMI / RFI AC noise suppression

Yes

AC suppression joule rating 480

Instantaneous AC suppression response time

PHYSICAL

Installation form factors supported with included accessories

Installation form factors supported with optional accessories

Primary form factor

UPS / Power Module dimensions in primary form factor (height x width x depth / inches)

4 post 19 inch rackmount (mounting rail kit included)

2 post rackmount (2POSTRMKITWM); Wallmount (2POSTRMKITWM); Tower (2-9USTAND)

Rackmount

3.5 x 17.5 x 14.2

UPS / Power Module dimensions in primary form factor (height x width x depth / cm)

Installed whole system total rack space height

(rack spaces)

Secondary form factor

Installed whole system dimensions in secondary form factor (height x width x depth / inches)

8.9 x 44.4 x 36.2

2U

Tower (requires

17.5 x 3.5 x 14.2

UPS dimensions in secondary form factor

(height x width x depth / cm)

44.4 x 8.9 x 36.2

35 UPS / Power Module weight

(lbs)

UPS / Power Module weight

(kg)

15.9

UPS Shipping dimensions

(height x width x depth / inches)

9.2 x 20 x 24

UPS Shipping dimensions

(height x width x depth / cm)

23.5 x 50.8 x 61

Shipping weight (lbs)

Shipping weight (kg)

46

20.9

2-9USTAND )

UPS housing material

Cooling method

Steel

Fan

Installed whole system dimensions in secondary form factor (height x width x depth / cm)

ENVIRONMENTAL

Operating Temperature

Range

44.45 x 8.89 x 36.07

+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius

Storage Temperature Range +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius

0 to 95%, non-condensing

47.3

Relative Humidity

AC mode BTU / hr. (full load)

Battery mode BTU / hr. (full load)

COMMUNICATIONS

Communications interface

Network monitoring port description

PowerAlert software

170

USB; DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface

Supports detailed monitoring of UPS and site power conditions

Communications cable

Included

USB and DB9 cabling included

WatchDog compatibility

LINE / BATTERY TRANSFER

Transfer time

Supports Watchdog application, OS and hard-reboot restart options for remote applications

2-4 milliseconds

83 Low voltage transfer to battery power (setpoint)

High voltage transfer to battery power (setpoint)

SPECIAL FEATURES

Grounding lug

Cold Start (startup in battery mode during a power failure)

147

Back panel grounding lug

Cold-start operation supported

Hot swappable batteries High availability UPS features

Green & high efficiency features

CERTIFICATIONS

UPS Certifications

Individually controllable load banks

Tested to UL1778 (USA); Tested to CSA (Canada); Tested to NOM (Mexico); Meets FCC Part 15 Category B

(EMI)

WARRANTY

Product Warranty Period

(Worldwide)

Connected Equipment

Insurance (U.S., Canada &

Puerto Rico)

2-year warranty, 3 year with

$250,000 registration

Ultimate Lifetime Insurance

. Note: registration is required for 3-year warranty.

Related Items

Optional Products

Product Type

Audio Cables

Extended Warranties

CT120

Related Model

WEXT5-500-1500

External Battery Packs

External Battery Packs

External Battery Packs

Power Distribution

BP24V15RT2U

BP24V28-2U

BP24V70-3U

PDU1215

Power Distribution PS7224

Rackmount/Wallmount Kits 2POSTRMKITWM

SNMP Accessories

SNMP Accessories

Surge Protectors

ENVIROSENSE

SNMPWEBCARD

DCATV

Description

Instant-Read- AC Outlet Circuit Tester

5-Year Extended Warranty - For Smart Line-Interactive and Online

Tower or Rack models, 1500VA or less

BP24V15RT2U - External Battery Pack for UPS System

BP24V28-2U - External Battery Pack for UPS System

BP24V70-3U - External Battery Pack for UPS System

Basic PDU / Power Distribution Unit - Safe, reliable power distribution for critical networking equipment

Tripp Lite Power Strip - Multiple outlets wherever you need them

Enables 2-Post Rackmount or Wallmount Installation of Select

Rackmount UPS Systems

Monitors temperature, humidity and contact-closure inputs. (Requires

SNMPWEBCARD or switched PDU.)

For remote monitoring and control via SNMP, Web, or Telnet.

Network Surge Suppressor - Essential protection for TV/VCR coaxial lines

1

1

1

1

1

1

Qty.

1

1

1

1

1

Surge Protectors

Surge Protectors

Tower Stands

USB Hubs/Accessories

DNET1

DTEL2

2-9USTAND

U022-010

Network Surge Suppressor - Essential protection for data and communication lines

Network Surge Suppressor - Essential protection for data and communication lines

Enables Tower Placement of Rackmount UPS Systems

10-ft. USB2.0 A/B Gold Device Cable

(A Male to B Male)

More information, including related products, owner's manuals, and additional technical specifications, can be found online at www.tripplite.com/en/products/model.cfm?txtModelID=3020 .

1

1

1

1

Copyright © 2012 Tripp Lite. All rights reserved. All trademarks are the sole property of their respective owners. Tripp Lite has a policy of continuous improvement. Specifications are subject to change without notice. Photos may differ slightly from final products.

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

advertisement