- Industrial & lab equipment
- Electrical equipment & supplies
- Power conditioning
- Uninterruptible power supplies (UPSs)
- Tripp Lite
- SmartPro SMART750RMXL2U
- Specification
advertisement
Tripp Lite
1111 West 35th Street
Chicago, IL 60609 USA
Telephone: +(773) 869 1234
E-mail: [email protected]
Model #: SMART750RMXL2U
SmartPro .75kVA Line Interactive Sine Wave UPS, Extended-run & SNMPWEBCARD options, 2U Rack/Tower,
USB, Serial, EPO, 120V
Highlights
750VA line interactive 2U rack/tower UPS; Sine wave output
120V nominal output during brownouts to 83V and overvoltages to 147V
USB, RS232, EPO and optional SNMP/Web card are available for simultaneous use
Expandable runtime, Status LEDs; 2 switched output load banks
NEMA 5-15P input; 6 NEMA 5-15R outlets
Description
Tripp Lite's SMART750RMXL2U intelligent, line interactive rack/tower uninterruptible power supply prevents data loss, downtime and equipment damage due to power outages, voltage fluctuations and transient surges. Requires only two rack spaces (2U) in a standard rack enclosure. Large internal batteries offer 30 minutes half load runtime and 12.5 minutes at full load. Extended runtime available with optional BP24V15RT2U,
BP24V28-2U (limit of one per UPS) or BP24V70-3U (multi-pack compatible) external battery packs. Maintains regulated 120V nominal output without using battery power during brownouts and overvoltages from 83 to 147V. 750VA/450 watt power handling capability supports a variety of networking, telecom and other sensitive electronic applications. Includes a total of 6 outlets arranged in 2 load banks that are individually controllable via software interface to reboot select equipment on demand or shed less significant loads to extend battery runtime for more critical equipment.
Supports remote monitoring of UPS and site power conditions via built-in USB and DB9 monitoring ports. Includes PowerAlert UPS monitoring and unattended shutdown software with complete cabling. Built-in accessory slot supports SNMP with optional SNMPWEBCARD adapter. Emergency
Power Off (EPO) interface offers option for instantaneous power-off of UPS and connected equipment in the case of fire or emergency.
Multi-function audible alarms and set of 5 front panel LEDs offer at-a-glance notification of UPS and line power status. Network-grade AC surge suppression protects equipment from damage and performance problems resulting from transient surges and line noise. Attractive all-black color scheme.
Package Includes
SMART750RMXL2U UPS System
PowerAlert software with USB and DB9 cables
Mounting hardware for 4 post rackmount installation
Cable for Emergency Power Off interface
Instruction manual
Features
SMART750RMXL2U line interactive UPS offers voltage regulation and battery support, plus complete AC surge suppression
Supports 2U rackmount and upright tower applications (2-9USTAND accessory sold separately)
Full time sine wave output offers guaranteed compatibility with all equipment types
Supports a max load of 750VA for 12.5 minutes and a half load of 375VA for 30 minutes
Extended runtime available with optional BP24V15RT2U, BP24V28-2U (limit of one per UPS) or BP24V70-3U (multi-pack compatible) external battery packs
Maintains regulated 120V nominal output 83 to 147V
750VA/450 watt power handling capability supports a variety of sensitive electronic loads
Includes 6 UPS supported outlets arranged in 2 individually controllable load banks
Built in USB and DB9 serial ports support remote monitoring of UPS and site power conditions
Built in accessory slot supports SNMP with optional SNMPWEBCARD adapter
Emergency Power Off (EPO) interface with cable
Multi-function audible alarms and set of 5 front panel LEDs
Network-grade AC surge suppression
Attractive all-black color scheme
UPS battery set ships fully assembled and ready for installation, no time consuming connection of internal batteries by user is necessary
Mounting hardware included for 4 post rackmount enclosures, 2 post telecom rack compatible with separate purchase 2POSTRMKITWM, compatible with upright tower installation with included hardware
Specifications
OUTPUT
Output Volt Amp Capacity
(VA)
Output Watt Capacity
(watts)
Output power factor
Nominal Output Voltage(s)
Supported
Frequency compatibility
Output voltage regulation
(line mode)
Output voltage regulation
(Battery mode)
Built-in UPS output receptacles
Built-in controllable switched load banks
Output AC waveform (AC mode)
Output AC waveform
(battery mode)
INPUT
Rated input current (at maximum load)
Nominal Input Voltage(s)
Supported
UPS input connection type
Input circuit breaker
UPS Input cord length (ft.)
UPS Input cord length (m)
Recommended Electrical
Service
Input cord length (ft.)
Input cord length (m)
BATTERY
Full load runtime (minutes)
750
450
0.6
120V
60 Hz
-21%, +8%
+/- 5%
6 5-15R outlet(s)
Two switchable two-outlet 5-15R load banks
Sine wave
Pure Sine wave
6.8A
120V AC
5-15P
15A
10 ft / 3m
3.05
15A 120V
10
3
12.5 min. (450w)
Half load runtime (minutes) 30 min. (225w)
Expandable battery runtime Extended runtime supported via optional external battery packs
External battery pack compatibility
BP24V15RT2U (limit 1); BP24V28-2U (limit 1); BP24V70-3U (multi-pack compatible)
DC system voltage (VDC)
Battery recharge rate
(included batteries)
Replacement battery cartridge (internal UPS battery replacement)
24
Less than 4 hours from 10% to 90%
RBC92-2U
Battery Access
Battery replacement description
VOLTAGE REGULATION
Voltage regulation description
Front panel battery access door
Hot-swappable, user replaceable batteries
Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 83 to 147
Overvoltage correction Input voltages between 128 and 147 are reduced by 12%
Undervoltage correction
LEDS ALARMS & SWITCHES
Input voltages between 83 and 107 are boosted by 14%
LED Indicators 5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status
Alarms
Alarm cancel operation
Audible alarm indicates power-failure, overload and low-battery conditions
Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate low-battery status
Switches
SURGE / NOISE SUPPRESSION
2 Switches control off/on power status and alarm-cancel/self-test operation
UPS AC suppression joule rating
480 joules
EMI / RFI AC noise suppression
Yes
AC suppression joule rating 480
Instantaneous AC suppression response time
PHYSICAL
Installation form factors supported with included accessories
Installation form factors supported with optional accessories
Primary form factor
UPS / Power Module dimensions in primary form factor (height x width x depth / inches)
4 post 19 inch rackmount (mounting rail kit included)
2 post rackmount (2POSTRMKITWM); Wallmount (2POSTRMKITWM); Tower (2-9USTAND)
Rackmount
3.5 x 17.5 x 14.2
UPS / Power Module dimensions in primary form factor (height x width x depth / cm)
Installed whole system total rack space height
(rack spaces)
Secondary form factor
Installed whole system dimensions in secondary form factor (height x width x depth / inches)
8.9 x 44.4 x 36.2
2U
Tower (requires
17.5 x 3.5 x 14.2
UPS dimensions in secondary form factor
(height x width x depth / cm)
44.4 x 8.9 x 36.2
35 UPS / Power Module weight
(lbs)
UPS / Power Module weight
(kg)
15.9
UPS Shipping dimensions
(height x width x depth / inches)
9.2 x 20 x 24
UPS Shipping dimensions
(height x width x depth / cm)
23.5 x 50.8 x 61
Shipping weight (lbs)
Shipping weight (kg)
46
20.9
2-9USTAND )
UPS housing material
Cooling method
Steel
Fan
Installed whole system dimensions in secondary form factor (height x width x depth / cm)
ENVIRONMENTAL
Operating Temperature
Range
44.45 x 8.89 x 36.07
+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
Storage Temperature Range +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius
0 to 95%, non-condensing
47.3
Relative Humidity
AC mode BTU / hr. (full load)
Battery mode BTU / hr. (full load)
COMMUNICATIONS
Communications interface
Network monitoring port description
PowerAlert software
170
USB; DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface
Supports detailed monitoring of UPS and site power conditions
Communications cable
Included
USB and DB9 cabling included
WatchDog compatibility
LINE / BATTERY TRANSFER
Transfer time
Supports Watchdog application, OS and hard-reboot restart options for remote applications
2-4 milliseconds
83 Low voltage transfer to battery power (setpoint)
High voltage transfer to battery power (setpoint)
SPECIAL FEATURES
Grounding lug
Cold Start (startup in battery mode during a power failure)
147
Back panel grounding lug
Cold-start operation supported
Hot swappable batteries High availability UPS features
Green & high efficiency features
CERTIFICATIONS
UPS Certifications
Individually controllable load banks
Tested to UL1778 (USA); Tested to CSA (Canada); Tested to NOM (Mexico); Meets FCC Part 15 Category B
(EMI)
WARRANTY
Product Warranty Period
(Worldwide)
Connected Equipment
Insurance (U.S., Canada &
Puerto Rico)
2-year warranty, 3 year with
$250,000 registration
Ultimate Lifetime Insurance
. Note: registration is required for 3-year warranty.
Related Items
Optional Products
Product Type
Audio Cables
Extended Warranties
CT120
Related Model
WEXT5-500-1500
External Battery Packs
External Battery Packs
External Battery Packs
Power Distribution
BP24V15RT2U
BP24V28-2U
BP24V70-3U
PDU1215
Power Distribution PS7224
Rackmount/Wallmount Kits 2POSTRMKITWM
SNMP Accessories
SNMP Accessories
Surge Protectors
ENVIROSENSE
SNMPWEBCARD
DCATV
Description
Instant-Read- AC Outlet Circuit Tester
5-Year Extended Warranty - For Smart Line-Interactive and Online
Tower or Rack models, 1500VA or less
BP24V15RT2U - External Battery Pack for UPS System
BP24V28-2U - External Battery Pack for UPS System
BP24V70-3U - External Battery Pack for UPS System
Basic PDU / Power Distribution Unit - Safe, reliable power distribution for critical networking equipment
Tripp Lite Power Strip - Multiple outlets wherever you need them
Enables 2-Post Rackmount or Wallmount Installation of Select
Rackmount UPS Systems
Monitors temperature, humidity and contact-closure inputs. (Requires
SNMPWEBCARD or switched PDU.)
For remote monitoring and control via SNMP, Web, or Telnet.
Network Surge Suppressor - Essential protection for TV/VCR coaxial lines
1
1
1
1
1
1
Qty.
1
1
1
1
1
Surge Protectors
Surge Protectors
Tower Stands
USB Hubs/Accessories
DNET1
DTEL2
2-9USTAND
U022-010
Network Surge Suppressor - Essential protection for data and communication lines
Network Surge Suppressor - Essential protection for data and communication lines
Enables Tower Placement of Rackmount UPS Systems
10-ft. USB2.0 A/B Gold Device Cable
(A Male to B Male)
More information, including related products, owner's manuals, and additional technical specifications, can be found online at www.tripplite.com/en/products/model.cfm?txtModelID=3020 .
1
1
1
1
Copyright © 2012 Tripp Lite. All rights reserved. All trademarks are the sole property of their respective owners. Tripp Lite has a policy of continuous improvement. Specifications are subject to change without notice. Photos may differ slightly from final products.
advertisement