im Vertrieb von CAMBOARD Electronics

Kramer Electronics, Ltd.

USER MANUAL

Model:

VS-48HDxl

3G HD/SD SDI 4x8 Matrix Switcher www.camboard.de

Tel. 07131 911201

Fax 07131 911203 [email protected]

Contents

1

2

Introduction

Getting Started

2.1

Quick Start

3

4

Overview

Your VS-48HDxl 3G HD/SD SDI 4x8 Matrix Switcher

4.1

Using the IR Transmitter

5

6

Installing the VS-48HDxl in a Rack

Connecting the VS-48HDxl 3G HD/SD SDI 4x8 Matrix Switcher

6.1

Connecting the VS-48HDxl in the Dual-Link Mode

6.2

Working Mode Setting

6.3

Dipswitch Settings

6.3.1

Setting the Setup Dipswitches

6.4

Controlling via RS-232 (for example, using a PC)

6.5

Controlling via the RS-485 Port

6.6

Factory Reset

6.7

Switching Genlocked Video Signals

6.8

Controlling via ETHERNET

6.8.1

Connecting the ETHERNET Port directly to a PC (Crossover Cable)

17

17

6.8.2

Connecting the ETHERNET Port via a Network Hub (Straight-Through Cable) 19

6.8.3

Configuring the Ethernet Port

6.9

Controlling via the REMOTE Connector

7 Operating the VS-48HDxl

7.1

Switching OUT-IN Combinations

7.1.1

Switch OUT-IN Combinations

7.1.2

Switch OUT-IN Combinations in the Dual-Link Mode

7.2

Confirming Settings

7.2.1

Toggling between the AT ONCE and CONFIRM Modes

7.2.2

Confirming a Switching Action

7.3

Storing/Recalling Input/Output Configurations

7.3.1

Storing an Input/Output Configuration

7.3.2

Recalling an Input/Output Configuration

7.4

8

Locking the Front Panel

Technical Specifications

9 Table of Hex Codes for Serial Communication

10 Kramer Protocol 2000

23

24

24

25

22

22

22

23

15

16

16

17

12

13

14

14

9

10

4

8

1

3

1

1

20

21

21

22

19

19

20

20 www.camboard.de

Tel. 07131 911201

Fax 07131 911203 [email protected]

Figures

Figure 1: VS-48HDxl 3G HD/SD SDI 4x8 Matrix Switcher

Figure 2: Connecting the VS-48HDxl 3G HD/SD SDI 4x8 Matrix Switcher

Figure 4: VS-48HDxl SETUP Dipswitches

Figure 5: Connecting a PC without using a Null-modem Adapter

Figure 6: Controlling via RS-485 (for example, using an RC-3000)

Figure 7: Local Area Connection Properties Window

Figure 8: Internet Protocol (TCP/IP) Properties Window

Figure 9: Using the Remote Connector

5

11

Figure 3: Connecting the Dual-Link VS-48HDxl 3G HD/SD-SDI 4x8 Matrix Switcher 13

14

15

16

18

18

19

Tables

Table 1: Front Panel VS-48HDxl 3G HD/SD SDI 4x8 Matrix Switcher

Table 2: Rear Panel VS-48HDxl 3G HD/SD SDI 4x8 Matrix Switcher

Table 3: Machine # Dipswitch Settings

Table 4: Technical Specifications of the VS-48HDxl

Table 5: VS-48HDxl Hex Codes for Switching via RS-232/RS-485

Table 6: Protocol Definitions

Table 7: Instruction Codes for Protocol 2000

14

24

6

7

24

25

26 www.camboard.de

Tel. 07131 911201

Fax 07131 911203 [email protected]

1 Introduction

Welcome to Kramer Electronics! Since 1981, Kramer Electronics has been providing a world of unique, creative, and affordable solutions to the vast range of problems that confront the video, audio, presentation, and broadcasting professional on a daily basis. In recent years, we have redesigned and upgraded most of our line, making the best even better! Our 1,000-plus different models now appear in 11 groups function.

1 that are clearly defined by

Congratulations on purchasing your Kramer VS-48HDxl 3G HD/SD SDI 4x8

Matrix Switcher . This product is ideal for:

Broadcasting and production studios

Presentation applications

The package includes the following items:

VS-48HDxl 3G HD/SD SDI 4x8 Matrix Switcher

Power cord 2

Null-modem adapter and infrared remote control transmitter

This user manual 3

2 Getting Started

We recommend that you:

Unpack the equipment carefully and save the original box and packaging materials for possible future shipment

Review the contents of this user manual

Use Kramer high-performance high-resolution cables 4

2.1 Quick Start

This quick start chart summarizes the basic setup and operation steps.

1 GROUP 1: Distribution Amplifiers; GROUP 2: Switchers and Matrix Switchers; GROUP 3: Control Systems;

GROUP 4: Format/Standards Converters; GROUP 5: Range Extenders and Repeaters; GROUP 6: Specialty AV Products;

GROUP 7: Scan Converters and Scalers; GROUP 8: Cables and Connectors; GROUP 9: Room Connectivity;

GROUP 10: Accessories and Rack Adapters; GROUP 11: Sierra Products

2 We recommend that you use only the power cord supplied with this device

3 Download up-to-date Kramer user manuals from the Internet at this URL: http://www.kramerelectronics.com

4 The complete list of Kramer cables is on our Web site at http://www.kramerelectronics.com www.camboard.de

Tel. 07131 911201

Fax 07131 911203 [email protected]

www.camboard.de

Tel. 07131 911201

Fax 07131 911203 [email protected]

3 Overview

The Kramer VS-48HDxl can be used as a high-performance 4x8 matrix switcher or as a dual-link 2x4 switcher, which lets you simultaneously route any of the inputs to any or all of the outputs for all SDI video signals, using

BNC connectors.

In particular, the VS-48HDxl features:

Cable equalization up to 350m for SD 1 signals, 140m for 1.5GHz HD signals, and 120m for 3GHz HD signals

2

Operation of up to 2.97Gbps – enabling it to be used for standard definition, high definition and the new 3G high definition serial digital video signals (SD/HD-SDI)

SMPTE 259M, 292M and 424M and 372M (for dual-link HD-SDI signals) compliance and support for data rates of 270Mbps, 1483.5Mbps,

1485Mbps and 2970Mbps

Reclocking and equalization on each input, storing and recalling setups, and a TAKE button for the execution of multiple switches all at once

Selector buttons that automatically light up in different colors—green, when the VS-48HDxl detects a ‘standard definition’ signal, or blue, when it detects a ‘high definition’ signal

The ability to switch genlocked video signals according to timing of the

GENLOCK reference input. Switching according to the Bi-level or Trilevel Genlock input according to SMPTE RP-168 3

The VS-48HDxl is housed in a 19" 1U rack-mountable enclosure, and is fed from a 100-240 VAC universal switching power supply. The unit can be controlled via the front panel buttons or via:

An infrared remote control transmitter

An infrared remote extension cable transmitter

Remotely, by RS-232 or RS-485 serial commands transmitted by a PC, touch screen system, or other serial controller

The ETHERNET

Remote contact closure for forced operation

1 Standard Definition (SD) means an NTSC or PAL compatible video format, consisting of 480 (for NTSC) or 576 (for PAL) lines of interlaced video

2 High Definition (HD) means a video format, consisting of 720 active lines of progressive video or 1080 lines of progressive or interlaced video

3 The sources must be genlocked to the GENLOCK input in order to switch cleanly www.camboard.de

Tel. 07131 911201

Fax 07131 911203 [email protected]

To achieve the best performance:

Connect only good quality connection cables, thus avoiding interference, deterioration in signal quality due to poor matching, and elevated noise levels (often associated with low quality cables)

Avoid interference from neighboring electrical appliances that may adversely influence signal quality and position your Kramer VS-48HDxl from moisture, excessive sunlight and dust

4 Your VS-48HDxl 3G HD/SD SDI 4x8 Matrix Switcher

Figure 1 , Table 1 , and Table 2 define the VS-48HDxl 3G HD/SD SDI 4x8

Matrix Switcher . www.camboard.de

Tel. 07131 911201

Fax 07131 911203 [email protected]

im Vertrieb von

Figure 1: VS-48HDxl 3G HD/SD SDI 4x8 Matrix Switcher

www.camboard.de

Tel. 07131 911201

Fax 07131 911203

Table 1: Front Panel VS-48HDxl 3G HD/SD SDI 4x8 Matrix Switcher

# Feature

1 IR Receiver

2 POWER Switch

3 OUTPUT (DUAL LINK)

Selector Buttons

4 INPUT (DUAL LINK)

Selector Buttons

5 STO (STORE) Button

6 TAKE Button

7 ALL Button

8 RCL ( RECALL ) Button

9 OFF Button

10 LOCK Button

11 7-segment Display

Function

The red LED is illuminated when receiving signals from the Infrared remote control transmitter

Illuminated switch for turning the unit ON or OFF

Select the output to which the input is switched (from 1 to 8)

In the dual-link mode, select the output DUAL LINK 1 to DUAL LINK 4 to which the input is switched

Select the input to switch to the output (from 1 to 4)

In the dual-link mode, select input DUAL LINK 1 or DUAL LINK 2 to switch to the outputs

Press IN buttons 1, 2 and 3 simultaneously to reset the machine to its factory default values

1

(see section 6.6)

Use to set the resolution when switching genlocked video signals (see section 6.7)

Pressing STO followed by an INPUT / OUTPUT button stores the current setting

2

Pressing TAKE toggles the mode between the CONFIRM mode 3 and the AT ONCE mode (user confirmation per action is unnecessary).

When in CONFIRM mode, the TAKE button implements a pending operation 4

Pressing ALL followed by an INPUT button, connects that input to all outputs 5

Pressing the RCL button and the corresponding INPUT / OUTPUT key displays a setup from the non-volatile memory. After pressing the same memory location the second time, the settings will take effect

An OFF OUT combination disconnects that output from the inputs; an

OFF ALL combination disconnects all the outputs

Press and hold 6 to toggle between the 4x switcher mode and the dual-link 2x4 switcher mode

Disengages/engages the front panel buttons

Displays the selected input switched to the output (marked above each input)

1 The 7-segment display shows 12341234, indicating that the operation mode is normal, and that the setups stored via the

INPUT/OUTPUT buttons have been erased

2 For example, press STO and then the Output button # 3 to store in Setup # 3

3 When in Confirm mode, the TAKE button illuminates

4 See section 7.2

5 For example, press ALL and then Input button # 2 to connect input # 2 to all the outputs

6 For more than 3 seconds www.camboard.de

Tel. 07131 911201

Fax 07131 911203 [email protected]

Table 2: Rear Panel VS-48HDxl 3G HD/SD SDI 4x8 Matrix Switcher

# Feature Function

12 GENLOCK BNC Connector Connect to the Genlock source

13 TERM 75 Button Press to terminate the Genlock source (75 ) or release for looping

1

14 LOOP BNC Connector

15 DUAL LINK INPUT BNC

Connectors

16 INPUT BNC Connectors

Connect to the GENLOCK connector of the next unit in the line

In the dual-link mode, connect the source to inputs 1 and 2 and/or inputs 3 and 4 (DUAL LINK 1 and/or DUAL LINK 2)

Connect to the serial digital video sources (from 1 to 4)

17 DUAL LINK OUTPUT

Connectors

BNC In the dual-link mode, connect the acceptors to outputs 1 and 2 and/or outputs 3 and 4 and/or outputs 5 and 6 and/or outputs 7 and 8 (DUAL

LINK 1 and/or DUAL LINK 2 and/or DUAL LINK 3 and/or DUAL LINK 4, respectively)

18 OUTPUT BNC Connectors Connect to the serial digital video acceptors (from 1 to 8)

19

20

RS-232

RESET

9-pin D-sub Port

Button

Connects to the PC or the Remote Controller

Press to reset Ethernet to factory default definitions 2 :

IP number 192.168.1.39

Mask – 255.255.255.0

Gateway – 192.168.1.1

21 ETHERNET RJ-45 Connector Connects to the PC or other Serial Controller through computer networking

22 REMOTE INPUT

Block Connectors

Terminal Connect to dry contact switches

3

(from 1 to 4)

23 REMOTE OUTPUT

Terminal Block Connectors

Connect to dry contact switches (from 1 to 8)

24

25 REMOTE IR Opening 5

26

RS-485

Terminal Block Port

SETUP

Detachable

Dipswitches

Pin G is for the Ground connection

4

; pins B (-) and A (+) are for RS-485

Connects to an external IR receiver unit for controlling the machine via an

IR remote controller (instead of using the front panel IR receiver)

Dipswitches for setup of the unit

6

27 Power Connector with Fuse AC connector enabling power supply to the unit

1 Push in to terminate the input. Release when the input extends to another unit

2 First disconnect the power cord and then connect it again while pressing the ETH Factory Reset button. The unit will power up and load its memory with the factory default definitions

3 See section 6.9

4 The ground connection is sometimes connected to the shield of the RS-485 cable. In most applications, the ground is not connected

5 Covered by a cap. The 3.5mm connector at the end of the internal IR connection cable fits through this opening

6 Optional. Can be used instead of the front panel (built-in) IR receiver to remotely control the machine (only if the internal

IR connection cable has been installed)

7 www.camboard.de

Tel. 07131 911201

Fax 07131 911203 [email protected]

4.1 Using the IR Transmitter

You can use the RC-IR2 IR transmitter to control the machine via the built-in

IR receiver on the front panel or, instead, via an optional external IR receiver 1 .

The external IR receiver can be located 15 meters away from the machine.

This distance can be extended to up to 60 meters when used with three extension cables 2 .

Before using the external IR receiver, be sure to arrange for your Kramer dealer to insert the internal IR connection cable 3 with the 3.5mm connector that fits into the REMOTE IR opening on the rear panel.

Connect the external IR receiver to the REMOTE IR 3.5mm connector.

1 Model: C-A35M/IRR-50

2 Model: C-A35M/A35F-50

3 P/N: 505-70434010-S www.camboard.de

Tel. 07131 911201

Fax 07131 911203 [email protected]

5 Installing the VS-48HDxl in a Rack

This section describes how to install the VS-48HDxl in a rack.

Before Installing in a rack

Before installing in a rack, be sure that the environment is within the recommended range:

Operating temperature range +5º to +45º C (41º to 113º F)

Operating humidity range 10 to 90% RHL, non-condensing

Storage temperature range -20º to +70º C (-4º to 158º F)

Storage humidity range 5 to 95% RHL, non-condensing

How to Rack Mount

To rack-mount a machine:

1. Attach both ear brackets to the machine. To do so, remove the screws from each side of the machine (3 on each side), and replace those screws through the ear brackets.

CAUTION !!

When installing on a 19" rack, avoid hazards by taking care that:

1. It is located within the recommended environmental conditions, as the operating ambient temperature of a closed or multi unit rack assembly may exceed the room ambient temperature.

2. Once rack mounted, enough air will still flow around the machine.

3. The machine is placed straight in the correct horizontal position.

4. You do not overload the circuit(s). When connecting the machine to the supply circuit, overloading the circuits might have a detrimental effect on overcurrent protection and supply wiring. Refer to the appropriate nameplate ratings for information. For example, for fuse replacement, see the value printed on the product label.

5. The machine is earthed (grounded) in a reliable way and is connected only to an electricity socket with grounding. Pay particular attention to situations where electricity is supplied indirectly (when the power cord is not plugged directly into the socket in the wall), for example, when using an extension cable or a power strip, and that you use only the power cord that is supplied with the machine.

2. Place the ears of the machine against the rack rails, and insert the proper screws (not provided) through each of the four holes in the rack ears.

Note that:

In some models, the front panel may feature built-in rack ears

Detachable rack ears can be removed for desktop use

Always mount the machine in the rack before you attach any cables or connect the machine to the power

If you are using a Kramer rack adapter kit (for a machine that is not

19"), see the Rack Adapters user manual for installation instructions

(you can download it at: http://www.kramerelectronics.com)

9 www.camboard.de

Tel. 07131 911201

Fax 07131 911203 [email protected]

6 Connecting the VS-48HDxl 3G HD/SD SDI 4x8 Matrix Switcher

To connect the VS-48HDxl 3G HD/SD SDI 4x8 Matrix Switcher , as illustrated in the example in Figure 2 , do the following 1 :

1. Connect up to four SDI sources to the SDI INPUT BNC connectors (for example, an HD/SD SDI camera to input 1 and a 3G HD video server to input 4).

2. Connect the SDI OUTPUT BNC connectors to up to mixer).

2 eight SDI acceptors

(for example, output 1 to a Preview display, and output 8 to an HD SDI

3. Set the dipswitches (see section 6.3).

4. If required 3 , connect:

A Genlock source to the GENLOCK BNC connector

The LOOP BNC connector to the GENLOCK connector of the next unit in the line, and release the TERM button for looping 4

5. Connect a PC and/or controller (if required), to the:

RS-232 port (see section 6.4), and/or

RS-485 port (see section 6.5), and/or

ETHERNET connector (see section 6.6)

6. If required 3 , connect a remote dry contact switch (refer to section 6.9).

7. Connect 3 the power cord 5 .

1 Switch OFF the power on each device before connecting it to your VS-48HDxl. After connecting your VS-48HDxl, switch on its power and then switch on the power on each device

2 When only one output is required, connect that output, and leave the other outputs unconnected

3 Not illustrated in Figure 2

4 Pushed in terminates the input. Release when the input extends to another unit

5 We recommend that you use only the power cord that is supplied with this machine www.camboard.de

Tel. 07131 911201

Fax 07131 911203 [email protected]

Figure 2: Connecting the VS-48HDxl 3G HD/SD SDI 4x8 Matrix Switcher

11 www.camboard.de

Tel. 07131 911201

Fax 07131 911203 [email protected]

6.1 Connecting the VS-48HDxl in the Dual-Link Mode

You can use your VS-48HDxl in the dual-link mode to switch any of the two dual-link SDI inputs to any or all of the four dual-link SDI outputs, as the illustration in Figure 3 shows.

To connect the VS-48HDxl 3G HD/SD-SDI 4x4 Matrix Switcher in the duallink mode, do the following 1 :

1. Connect one or both of the SDI sources to the INPUT DUAL LINK BNC connectors. For example, a dual-link HD/SD SDI camera to DUAL LINK 1

(inputs 1 and 2) and a dual-link 3G HD video server to DUAL LINK 2

(inputs 3 and 4).

2. Connect the SDI OUTPUT BNC connectors to up to four 2 SDI acceptors. For example, OUTPUT DUAL LINK 1 (outputs 1 and 2) to a dual-link preview display, and OUTPUT DUAL LINK 4 (outputs 7 and 8) to a dual-link HD

SDI mixer.

3. Set the dipswitches (see section 6.3).

4. If required 3 , connect:

A Genlock source to the GENLOCK BNC connector

The LOOP BNC connector to the GENLOCK connector of the next unit in the line, and release the TERM button for looping 4

5. Connect a PC and/or controller (if required), to the:

RS-232 port (see section 6.4), and/or

RS-485 port (see section 6.5), and/or

ETHERNET connector (see section 6.6)

6. If required 3 , connect a remote dry contact switch (refer to section 6.9).

7. Connect 3 the power cord 5 .

8. Set the machine to the dual-link mode (see section 6.2).

1 Switch OFF the power on each device before connecting it to your VS-48HDxl. After connecting your VS-48HDxl, switch on its power and then switch on the power on each device

2 When only one output is required, connect that output, and leave the other output unconnected

3 Not illustrated in Figure 2

4 Pushed in terminates the input. Release when the input extends to another unit

5 We recommend that you use only the power cord that is supplied with this machine www.camboard.de

Tel. 07131 911201

Fax 07131 911203 [email protected]

Figure 3: Connecting the Dual-Link VS-48HDxl 3G HD/SD-SDI 4x8 Matrix Switcher

6.2 Working Mode Setting

You can set the VS-48HDxl to work in the dual-link mode as follows:

To switch to the dual-link mode, press and hold the OFF front panel button for 3 seconds until a red dot illuminates on the display (on the fourth segment of the 7-segment display) and the OFF button blinks

To exit the dual-link mode, press and hold the OFF front panel button for

3 seconds until the red dot on the display disappears and the OFF button blinks

13 www.camboard.de

Tel. 07131 911201

Fax 07131 911203 [email protected]

6.3 Dipswitch Settings

By default, all dipswitches are set to OFF.

Figure 4 illustrates the VS-48HDxl dipswitches:

Figure 4: VS-48HDxl SETUP Dipswitches

6.3.1 Setting the Setup Dipswitches

The setup dipswitches determine the address of each VS-48HDxl unit when several VS-48HDxl units are connected to a PC or serial controller. Set the address of the unit using the SETUP dipswitches 1, 2, 3 and 4, according to

Table 3 .

When using a standalone VS-48HDxl unit, set the address to 1.

When connecting more than one VS-48HDxl unit, set the address of the first machine (the Master) that is closest to the PC, to 1 (dipswitches are set to

OFF). Each additional VS-48HDxl unit must have a unique address.

Table 3: Machine # Dipswitch Settings

Address DIP 1

1 (default) OFF

2

3

OFF

OFF

4

5

6

7

8

OFF

OFF

OFF

OFF

OFF

DIP 2

OFF

OFF

OFF

OFF

ON

ON

ON

ON

DIP 3

OFF

OFF

ON

ON

OFF

OFF

ON

ON

DIP 4

OFF

ON

OFF

ON

OFF

ON

OFF

ON www.camboard.de

Tel. 07131 911201

Fax 07131 911203 [email protected]

6.4 Controlling via RS-232 (for example, using a PC)

To connect a PC to the VS-48HDxl unit, using the Null-modem adapter provided with the machine (recommended):

Connect the RS-232 9-pin D-sub rear panel port on the VS-48HDxl unit to the Null-modem adapter and connect the Null-modem adapter with a

9-wire flat cable to the RS-232 9-pin D-sub port on your PC

To connect a PC to the VS-48HDxl unit, without using a Null-modem adapter:

Connect the RS-232 9-pin D-sub port on your PC to the RS-232 9-pin

D-sub rear panel port on the VS-48HDxl unit, as Figure 5 illustrates

PIN 5 Connected to PIN 5 (Ground)

PIN 3 Connected to PIN 2

PIN 2 Connected to PIN 3

9-pin D-sub

(From PC)

9-pin D-sub

(Male)

PIN 4 is connected to PIN 6

PINs 8, 7, 1 are connected together

If a shielded cable is used, connect the shield to PIN 5

Figure 5: Connecting a PC without using a Null-modem Adapter

15 www.camboard.de

Tel. 07131 911201

Fax 07131 911203 [email protected]

6.5 Controlling via the RS-485 Port

To cascade up to eight individual VS-48HDxl units, via RS-485 (with control via a Master Programmable Remote Control system such as the Kramer

RC-3000 ), as Figure 6 illustrates, do the following:

1. Connect the “A” (+) and “B” (-) PINS on the RS-485 terminal block port of the RC-3000 to the “A” (+) and “B” (-) PINS, respectively, on each of the eight VS-48HDxl units. (If using shielded twisted pair cable, the shield is usually connected to the “G” (Ground) PIN of the first unit).

2. Set the first VS-48HDxl unit as MACHINE # 1 and the following seven

VS-48HDxl units as MACHINE # 2 to MACHINE # 8, according to

Table 3 .

KEYBOARD EXTENSION

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

REMOTE CONTACT

1 2 3 4 5 6 7 8 G

RS-485

RS-232 IN RS-232 OUT

12 VDC

+

_

RS-485 PINOUT

A

B

G

MACHINE # 1

MACHINE # 8

Figure 6: Controlling via RS-485 (for example, using an RC-3000)

6.6 Factory Reset

Press and hold the input buttons 1, 2 and 3 simultaneously for 3 seconds until the three buttons flash to reset the machine to its default values. www.camboard.de

Tel. 07131 911201

Fax 07131 911203 [email protected]

6.7 Switching Genlocked Video Signals

The genlock feature lets you switch genlocked video signals according to timing of the GENLOCK reference input 1 .

Connect the GENLOCK cable.

If the HD input signal 2 to set it up as follows:

that is connected is one of the following, it is necessary

1080i@60Hz: press and hold INPUT 1 button for 3 seconds. The button will flash 3 to indicate that the set up was completed

1080i@50Hz or 720p@50Hz: press and hold INPUT 2 button for 3 seconds.

The button will flash 3 to indicate that the set up was completed

720p@60Hz: press and hold INPUT 3 button for 3 seconds.

The button will flash 3 to indicate that the set up was completed

When turning the machine ON, the appropriate button will flash to indicate the latest setup (last setup is saved).

6.8 Controlling via ETHERNET

You can connect the VS-48HDxl via the Ethernet, using a crossover cable

(see section 6.8.1) for direct connection to the PC or a straight-through cable

(see section 6.8.2) for connection via a network hub or network router 4 .

6.8.1 Connecting the ETHERNET Port directly to a PC (Crossover Cable)

You can connect the Ethernet port of the VS-48HDxl to the Ethernet port on your PC, via a crossover cable with RJ-45 connectors.

This type of connection is recommended for identification of the factory default

IP Address of the VS-48HDxl during the initial configuration

After connecting the Ethernet port, configure your PC as follows:

1. Right-click the My Network Places icon on your desktop.

2. Select Properties .

1 According to SMPTE RP-168. The sources must be genlocked to the GENLOCK input in order to switch cleanly

2 The unit will detect automatically when SD-SDI inputs are used

3 If a change is made to the resolution or refresh rate. The button will not flash if the new timing is the same as that previously selected

4 After connecting the Ethernet port, you have to install and configure your Ethernet Port and also install the COM Port

Redirector. For detailed instructions, see the “ Ethernet Configuration (Lantronix) guide.pdf” file in the technical support section on our Web site: http://www.kramerelectronics.com

17 www.camboard.de

Tel. 07131 911201

Fax 07131 911203 [email protected]

3. Right-click Local Area Connection Properties.

4. Select Properties .

The Local Area Connection Properties window appears.

5. Select the Internet Protocol (TCP/IP) and click the Properties Button (see

Figure 7).

Figure 7: Local Area Connection Properties Window

6. Select Use the following IP address, and fill in the details as shown in

Figure 8.

7. Click OK .

Figure 8: Internet Protocol (TCP/IP) Properties Window www.camboard.de

Tel. 07131 911201

Fax 07131 911203 [email protected]

6.8.2 Connecting the ETHERNET Port via a Network Hub (Straight-

Through Cable)

You can connect the Ethernet port of the VS-44HDxl to the Ethernet port on a network hub or network router, via a straight-through cable with RJ-45 connectors.

6.8.3 Configuring the Ethernet Port

After connecting the Ethernet port, you have to install and configure it.

For detailed instructions on how to install and configure your Ethernet port, see the “ Ethernet Configuration (FC-11) guide.pdf” on our Web site: http://www.kramerelectronics.com.

6.9 Controlling via the REMOTE Connector

Connecting the REMOTE terminal block connector to a dry contact switch enables you to route an input to an output by remote control.

To route input 1 to output 8 as an example (see Figure 9 ):

1. Momentarily touch output # 8 to

Ground (G)

2. Momentarily touch input # 1 to

Ground (G)

Figure 9: Using the Remote Connector

In the dual-link mode, only inputs 1 and 2 and outputs 1 to 4 are used (as are the INPUT and OUTPUT selector buttons, respectively). Remote input PINs 3 and 4 and Input Selector buttons 3 and 4 are not used, as well as Remote output PINs 5 to 8 and Output Selector buttons 5 to 8.

19 www.camboard.de

Tel. 07131 911201

Fax 07131 911203 [email protected]

7 Operating the VS-48HDxl

You can operate your VS-48HDxl using the:

Front panel buttons

RS-232/RS-485 serial commands transmitted by a PC, touch screen system, or other serial controller

Kramer RC-IR2 Infrared Remote Control Transmitter

Infrared remote extension cable transmitter

ETHERNET

7.1 Switching OUT-IN Combinations

Section 7.1.1 describes how to switch OUT-IN combinations and section 7.1.2 how to switch OUT-IN combinations in the dual link mode.

Note that:

The OUTPUT button color changes during routing according to the input button color: red (for standard definition) or blue (for high definition)

If no INPUT is connected to an OUTPUT, that OUTPUT button will not illuminate

If a source is connected to an INPUT, that INPUT button will illuminate

7.1.1 Switch OUT-IN Combinations

To switch an input to an output via the front panel buttons mode (see section 7.2), do the following:

1 , in the AT ONCE

1. Press an OUTPUT button from 1 through 8, or ALL.

The selected OUTPUT button illuminates brightly, as does the 7-segment display.

2. Press an INPUT button from 1 through 4 or OFF 2 .

The selected input switches to the selected output, and that input button illuminates brightly. The digits displayed in the 7-segment display change as appropriate.

1 For details of how to route an input to an output using the REMOTE connector, see section 6.9

2 For immediate switching www.camboard.de

Tel. 07131 911201

Fax 07131 911203 [email protected]

7.1.2 Switch OUT-IN Combinations in the Dual-Link Mode

To switch an input to an output in the dual-link mode, via the front panel buttons 1 , in the AT ONCE mode (see section 7.2), do the following:

1. Press an OUTPUT button (either 1, 2, 3, 4 or ALL).

The selected OUTPUT button illuminates brightly, as does the 7-segment display.

2. Press an INPUT button (either 1, 2 or OFF) 2 .

The selected input switches to the selected output, and that input button illuminates brightly. The digits displayed in the 7-segment display change as appropriate.

7.2 Confirming Settings

You can work in the AT ONCE or the CONFIRM mode (see section 7.2.1).

When the VS-48HDxl operates in the AT ONCE mode, pressing an

OUT-IN combination implements the switch immediately. In the CONFIRM mode, the TAKE button must be pressed to authorize the switch.

In the AT ONCE mode, you save time as execution is immediate and actions require no user confirmation. However, no protection is offered against changing an action in error.

In the CONFIRM mode:

You can key-in several actions and then confirm them by pressing the

“ TAKE” button to simultaneously activate the multiple switches

Every action requires user confirmation, protecting against erroneous switching

Execution is delayed until the user confirms the action

Note that after ten seconds the VS-48HDxl will go to standby mode and the buttons and the 7-segment display will illuminate less brightly.

1 For details of how to route an input to an output using the REMOTE connector, see section 6.9

2 For immediate switching

21 www.camboard.de

Tel. 07131 911201

Fax 07131 911203 [email protected]

7.2.1 Toggling between the AT ONCE and CONFIRM Modes

To toggle between the AT ONCE and CONFIRM modes, do the following:

1. Press the dim TAKE button to toggle from the AT ONCE mode (in which the

TAKE button is dim) to the CONFIRM mode (in which the TAKE button illuminates).

Actions now require user confirmation and the TAKE button illuminates.

2. Press the illuminated TAKE button to toggle from the CONFIRM mode back to the AT ONCE mode.

Actions no longer require user confirmation and the TAKE button no longer illuminates.

7.2.2 Confirming a Switching Action

To confirm a switching action (in CONFIRM mode where the TAKE button is illuminated), do the following:

1. Press an OUT-IN combination.

The 7-segment Display blinks 1 .

2. Press the TAKE button to confirm the action.

The 7-segment Display no longer blinks. The TAKE button turns off.

7.3 Storing/Recalling Input/Output Configurations

You can store and recall up to twelve setup configurations, as well as the working mode, using the four INPUT buttons and the eight OUTPUT buttons.

7.3.1 Storing an Input/Output Configuration

To store the current status in memory, do the following:

1. Set the working mode, see section 6.2.

2. Press the STO button.

The STO button illuminates.

3. Press one of the 12 INPUT / OUTPUT buttons (this will be the setup # in which the current configuration is stored).

The selected INPUT / OUTPUT button illuminates in blue. The memory stores the data at that reference.

To confirm the setup, press the INPUT/OUTPUT button again.

To cancel the setup, press the STO button once again

1 The timeout lasts for 10 seconds www.camboard.de

Tel. 07131 911201

Fax 07131 911203 [email protected]

7.3.2 Recalling an Input/Output Configuration

To recall an input/output configuration, do the following:

1. Press the RCL button.

The RCL button illuminates.

2. Press the appropriate INPUT / OUTPUT button (the button # corresponding to the setup #). That setup configuration blinks in the 7-segment display.

The memory recalls the stored data from that reference effect.

1 .

After pressing the same memory location the second time, the settings take

To cancel this action, press the RCL button once again

7.4 Locking the Front Panel

To prevent changing the settings accidentally or tampering with the unit via the front panel buttons, lock 2 your VS-48HDxl . Unlocking releases the protection mechanism.

To lock the VS-48HDxl :

Press the LOCK button until the LOCK button illuminates

The front panel is locked. Pressing a button will have no effect

To unlock the VS-48HDxl :

Press the illuminated LOCK button until the LOCK button is no longer illuminated

The front panel unlocks

1 The setup configuration is shown flashing in the 7-segment display, but it is not implemented at this stage

2 Nevertheless, even though the front panel is locked you can still operate via RS-232 or RS-485, as well as via the Kramer

IR Remote Control Transmitter

23 www.camboard.de

Tel. 07131 911201

Fax 07131 911203 [email protected]

8 Technical Specifications

Table 4 includes the technical specifications:

Table 4: Technical Specifications

1

of the VS-48HDxl

INPUTS:

DIMENSIONS:

WEIGHT:

ACCESSORIES:

OPTIONS:

4 SMPTE-259M / 292M / 424M / (372M for dual-link HD-SDI signals) serial video,

75 on BNC connectors

1 GENLOCK 75 / Hi-Z on a BNC connector, hi-level or tri-level sync

OUTPUTS:

OUTPUT LEVEL:

8 equalized and reclocked SMPTE-259M, 292M outputs 75 on BNC connectors

1 Looped GENLOCK 75 / Hi-Z on a BNC connector

800mVpp /75 ohms

DATA RATE:

CONTROLS:

Up to 2.97Gbps

Front-panel, RS-232; RS-485, ETHERNET, infrared remote, dry contact, and panel lock

POWER SOURCE: Universal, 100-240VAC, 50/60Hz 22VA

19 inch (W), 7 inch (D), 1U (H) rack mountable

2.6kg (5.7lbs) approx.

Power cord, Null-modem Adapter

External remote IR receiver cable 2

9 Table of Hex Codes for Serial Communication

Table 5 lists the Hex values for a single machine ( MACHINE # 1):

Table 5: VS-48HDxl Hex Codes for Switching via RS-232/RS-485

IN 1

IN 2

IN 3

IN 4

OUT 1 OUT 2 OUT 3 OUT 4 OUT 5 OUT 6 OUT 7 OUT 8

1 Specifications are subject to change without notice

2 P/N: C-A35M/IRR-50 www.camboard.de

Tel. 07131 911201

Fax 07131 911203 [email protected]

10 Kramer Protocol 2000

1

The VS-48HDxl is compatible with Kramer’ s Protocol 2000 (version 0.50)

(below). This RS-232/RS-485 communication protocol uses four bytes of information as defined below. For RS-232, a null-modem connection between the machine and controller is used. The default data rate is 9600 baud, with no parity, 8 data bits and 1 stop bit.

Table 6: Protocol Definitions

MSB

DESTI- INSTRUCTION

LSB

0

7

1st byte

1

7

2nd byte

1

7

3rd byte

D

6

I6

6

O6

6

NATION

N5

5

I5

5

O5

5

N4

4

I4

4

O4

4

N3

3

I3

3

INPUT

OUTPUT

O3

3

N2

2

I2

2

O2

2

N1

1

I1

1

O1

1

N0

0

I0

0

O0

0

MACHINE NUMBER

1

7

4th byte

OVR

6

X

5

M4

4

M3

3

M2

2

1 st BYTE: Bit 7 – Defined as 0.

D – “ DESTINATION” : 0 - for sending information to the switchers (from the PC);

M1

1

M0

0

1 - for sending to the PC (from the switcher).

N5…N0 – “ INSTRUCTION”

The function that is to be performed by the switcher(s) is defined by the INSTRUCTION (6 bits). Similarly, if a function is performed via the machine’ s keyboard, then these bits are set with the INSTRUCTION NO., which was performed. The instruction codes are defined according to the table below (INSTRUCTION NO. is the value to be set for N5…N0). nd BYTE: 2 Bit 7 – Defined as 1.

I6…I0 – “ INPUT” .

When switching (ie. instruction codes 1 and 2), the INPUT (7 bits) is set as the input number which is to be switched.

3

Similarly, if switching is done via the machine’ s front-panel, then these bits are set with the INPUT NUMBER which was switched. For other operations, these bits are defined according to the table. rd BYTE: Bit 7 – Defined as 1.

O6…O0 – “ OUTPUT” .

When switching (ie. instruction codes 1 and 2), the OUTPUT (7 bits) is set as the output number which is to be switched.

4

Similarly, if switching is done via the machine’ s front-panel, then these bits are set with the OUTPUT NUMBER which was switched. For other operations, these bits are defined according to the table. th BYTE: Bit 7 – Defined as 1.

Bit 5 – Don’ t care.

OVR – Machine number override.

M4…M0 – MACHINE NUMBER.

Used to address machines in a system via their machine numbers. When several machines are controlled from a single serial port, they are usually configured together with each machine having an individual machine number. If the OVR bit is set, then all machine numbers will accept (implement) the command, and the addressed machine will reply.

1 You can download our user-friendly “ Software for Calculating Hex Codes for Protocol 2000” from the technical support section on our Web site at: http://www.kramerelectronics.com

25 www.camboard.de

Tel. 07131 911201

Fax 07131 911203 [email protected]

For a single machine controlled via the serial port, always set M4…M0 = 1, and make sure that the machine itself is configured as MACHINE NUMBER = 1.

Table 7: Instruction Codes for Protocol 2000

Note: All values in the table are decimal, unless otherwise stated.

0

1

3

4

5

15

61

62

#

INSTRUCTION

DESCRIPTION

RESET VIDEO

SWITCH VIDEO

STORE VIDEO STATUS

RECALL VIDEO STATUS

REQUEST STATUS OF A

VIDEO OUTPUT

REQUEST WHETHER SETUP

IS DEFINED

IDENTIFY MACHINE

DEFINE MACHINE

DEFINITION FOR SPECIFIC INSTRUCTION

INPUT

0

Set equal to video input which is to be switched

(0 = disconnect)

Set as SETUP #

Set as SETUP #

Set as SETUP #

SETUP #

1 - video machine name

3 - video software version

1 - number of inputs

2 - number of outputs

3 - number of setups

OUTPUT

0

Set equal to video output which is to be switched

(0 = to all the outputs)

0 - to store

1 - to delete

0

Equal to output number whose

1

2

2, 3

2, 3

4, 3 status is reqd

0 - for checking if setup is defined 8

0 - Request first 4 digits

1 - Request first suffix

2 - Request second suffix

10 - Request first prefix

1 - for video

13

14

NOTE

NOTES on the above table:

NOTE 1 - When the master switcher is reset, (e.g. when it is turned on), the reset code is sent to the PC. If this code is sent to the switchers, it will reset according to the present power-down settings.

NOTE 2 - These are bi-directional definitions. That is, if the switcher receives the code, it will perform the instruction; and if the instruction is performed (due to a keystroke operation on the front panel), then these codes are sent. For example, if the

HEX code

01 85 88 83 was sent from the PC, then the switcher (machine 3) will switch input 5 to output 8. If the user switched input 1 to output 7 via the front panel keypad, then the switcher will send HEX codes:

41 81 87 83 to the PC.

When the PC sends one of the commands in this group to the switcher, then, if the instruction is valid, the switcher replies by sending to the PC the same four bytes that it was sent (except for the first byte, where the DESTINATION bit is set high).

NOTE 3 - SETUP # 0 is the present setting. SETUP # 1 and higher are the settings saved in the switcher's memory, (i.e. those used for Store and Recall).

NOTE 4 - The reply to a "REQUEST" instruction is as follows: the same instruction and INPUT codes as were sent are returned, and the OUTPUT is assigned the value of the requested parameter. The replies to instructions 10 and 11 are as per the definitions in instructions 7 and 8 respectively. For example, if the present status of machine number 5 is breakaway setting, then the reply to the HEX code

0B 80 would be HEX codes

80

80 85

4B 81 85

NOTE 8 - The reply is as in TYPE 3 above, except that here the OUTPUT is assigned with the value 0 if the setup is not defined / no valid input is detected; or 1 if it is defined / valid input is detected.

NOTE 13 - This is a request to identify the switcher/s in the system. If the OUTPUT is set as 0, and the INPUT is set as 1, 2,

5 or 7, the machine will send its name. The reply is the decimal value of the INPUT and OUTPUT. For example, for a 2216, the reply to the request to send the audio machine name would be (HEX codes):

7D 96 90 81 (i.e. 128dec+ 22dec for 2nd byte, and 128dec+ 16dec for 3rd byte). www.camboard.de

Tel. 07131 911201

Fax 07131 911203 [email protected]

If the request for identification is sent with the INPUT set as 3 or 4, the appropriate machine will send its software version number. Again, the reply would be the decimal value of the INPUT and OUTPUT - the INPUT representing the number in front of the decimal point, and the OUTPUT representing the number after it. For example, for version 3.5, the reply to the request to send the version number would be (HEX codes):

7D 83 85 81 (i.e. 128dec+ 3dec for 2nd byte, 128dec+ 5dec for 3rd byte).

If the OUTPUT is set as 1, then the ASCII coding of the lettering following the machine’ s name is sent. For example, for the

VS-7588YC, the reply to the request to send the first suffix would be (HEX codes):

7D D9 C3 81 (i.e. 128dec+ ASCII for “ Y” ; 128dec+ ASCII for “ C” ).

NOTE 14 - The number of inputs and outputs refers to the specific machine which is being addressed, not to the system. For example, if six 16X16 matrices are configured to make a 48X32 system (48 inputs, 32 outputs), the reply to the HEX code

81 82 (i.e. request the number of outputs) 3E 82 would be HEX codes

7E ie. 16 outputs

82 90 82

27 www.camboard.de

Tel. 07131 911201

Fax 07131 911203 [email protected]

im Vertrieb von CAMBOARD Electronics

LIMITED WARRANTY

Kramer Electronics (hereafter following terms.

Kramer

HOW LONG IS THE WARRANTY

) warrants this product free from defects in material and workmanship under the

Labor and parts are warranted for seven years from the date of the first customer purchase.

WHO IS PROTECTED?

Only the first purchase customer may enforce this warranty.

WHAT IS COVERED AND WHAT IS NOT COVERED

Except as below, this warranty covers all defects in material or workmanship in this product. The following are not covered by the warranty:

1. Any product which is not distributed by Kramer, or which is not purchased from an authorized Kramer dealer. If you are uncertain as to whether a dealer is authorized, please contact Kramer at one of the agents listed in the Web site www.kramerelectronics.com.

2. Any product, on which the serial number has been defaced, modified or removed, or on which the WARRANTY VOID

IF TAMPERED sticker has been torn, reattached, removed or otherwise interfered with.

3. Damage, deterioration or malfunction resulting from: i) Accident, misuse, abuse, neglect, fire, water, lightning or other acts of nature ii) Product modification, or failure to follow instructions supplied with the product iii) Repair or attempted repair by anyone not authorized by Kramer iv) Any shipment of the product (claims must be presented to the carrier) v) Removal or installation of the product vi) Any other cause, which does not relate to a product defect vii) Cartons, equipment enclosures, cables or accessories used in conjunction with the product

WHAT WE WILL PAY FOR AND WHAT WE WILL NOT PAY FOR

We will pay labor and material expenses for covered items. We will not pay for the following:

1. Removal or installations charges.

2. Costs of initial technical adjustments (set-up), including adjustment of user controls or programming. These costs are the responsibility of the Kramer dealer from whom the product was purchased.

3. Shipping charges.

HOW YOU CAN GET WARRANTY SERVICE

1. To obtain service on you product, you must take or ship it prepaid to any authorized Kramer service center.

2. Whenever warranty service is required, the original dated invoice (or a copy) must be presented as proof of warranty coverage, and should be included in any shipment of the product. Please also include in any mailing a contact name, company, address, and a description of the problem(s).

3. For the name of the nearest Kramer authorized service center, consult your authorized dealer.

LIMITATION OF IMPLIED WARRANTIES

All implied warranties, including warranties of merchantability and fitness for a particular purpose, are limited in duration to the length of this warranty.

EXCLUSION OF DAMAGES

The liability of Kramer for any effective products is limited to the repair or replacement of the product at our option. Kramer shall not be liable for:

1. Damage to other property caused by defects in this product, damages based upon inconvenience, loss of use of the product, loss of time, commercial loss; or:

2. Any other damages, whether incidental, consequential or otherwise. Some countries may not allow limitations on how long an implied warranty lasts and/or do not allow the exclusion or limitation of incidental or consequential damages, so the above limitations and exclusions may not apply to you.

This warranty gives you specific legal rights, and you may also have other rights, which vary from place to place.

NOTE: All products returned to Kramer for service must have prior approval. This may be obtained from your dealer.

This equipment has been tested to determine compliance with the requirements of:

EN-50081:

EN-50082:

CFR-47:

"Electromagnetic compatibility (EMC); generic emission standard.

Part 1: Residential, commercial and light industry"

"Electromagnetic compatibility (EMC) generic immunity standard.

Part 1: Residential, commercial and light industry environment".

FCC* Rules and Regulations:

Part 15: “ Radio frequency devices

Subpart B Unintentional radiators”

CAUTION!

Servicing the machines can only be done by an authorized Kramer technician. Any user who makes changes or modifications to the unit without the expressed approval of the manufacturer will void user authority to operate the equipment.

Use the supplied DC power supply to feed power to the machine.

Please use recommended interconnection cables to connect the machine to other components.

* FCC and CE approved using STP cable (for twisted pair products) www.camboard.de

Tel. 07131 911201

Fax 07131 911203 [email protected]

im Vertrieb von CAMBOARD Electronics

For the latest information on our products and a list of Kramer distributors, visit our Web site: www.kramerelectronics.com, where updates to this user manual may be found.

We welcome your questions, comments and feedback.

Caution

Safety Warning

:

Disconnect the unit from the power supply before opening/servicing. www.camboard.de

Kramer Electronics, Ltd.

Web site: www.kramerelectronics.com

E-mail: [email protected]

Tel. 07131 911201

Fax 07131 911203 [email protected]

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement