Enviro retreat Owner's Manual

Add to My manuals
41 Pages

advertisement

Enviro retreat Owner's Manual | Manualzz

SHERWOOD INDUSTRIES IS AN ENVIRONMENTALLY RESPONSIBLE COMPANY. THIS MANUAL IS PRINTED ON RECYCLED PAPER.

PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE Retreat

D I R E C T V E N T F I R E P L A C E

B Y : S H E R W O O D I N D U S T R I E S L T D

OWNER’S

MANUAL

WHAT TO DO IF YOU SMELL GAS

• Open windows/extinguish any open flame.

• Do not try to light any appliance.

• Do not touch any electrical switch or use any phone in your building.

• Immediately call your gas supplier from a neighbour’s phone. Follow the gas supplier’s instructions.

• If you cannot reach your gas supplier, call the fire department.

This appliance may be installed in an after-market permanently located, manufactured (mobile) home, where not prohibited by local codes.

This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used.

WARNING

If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

Installation and service must be performed by a qualified installer, service agency or the gas supplier.

FOR YOUR SAFETY

Do not store or use gasoline or other flammable vapours and liquids in the vicinity of this or any other appliance.

Massachusetts installations (Warning): This product must be installed by a licensed plumber or gas fitter when installed within the Commonwealth of Massachusetts.

Other Massachusetts code requirements: Flexible connector must not be longer than

36in, shut-off valve must be a “T” handle gas cock; only direct vent sealed combustion products are approved for bedrooms/bathrooms; fireplace dampers must be removed or welded in the open position prior to the installation of a fireplace insert or gas log.

50-1269

2

Safety Precautions

FOR SAFE INSTALLATION AND OPERATION OF YOUR “ENVIRO” HEATER,

PLEASE CAREFULLY READ THE FOLLOWING INFORMATION:

• All ENVIRO gas-fired appliances must be installed in accordance with their instructions. Carefully read all the instructions in this manual first. Consult the building authority having jurisdiction to determine the need for a permit prior to commencing the installation.

• NOTE: Failure to follow these instructions could cause a malfunction of the fireplace, which could result in death, serious bodily injury, and/or property damage.

• Failure to follow these instructions may also void your fire insurance and/or warranty.

GENERAL

• Installation and repair should be done by a qualified service person. The appliance should be inspected before the first use and, at least, annually by a qualified service person. More frequent cleaning may be required due to excessive lint from carpeting, bedding material, etc. It is imperative the control compartments, burners and circulating air passageways of the appliance be kept clean.

• Due to high temperatures, the appliance should be located out of high traffic areas and away from furniture and draperies.

Children and adults should be alerted to the hazards of high surface temperatures and should stay away to avoid burn or clothing ignition.

• Young children should be carefully supervised when in the same room as the appliance.

• Clothing or other flammable materials should not be placed on or near the appliance.

FOR YOUR SAFETY

• Installation and service must be performed by a qualified installer, service agency or gas supplier.

• This installation must conform to local codes or, in the absence of local codes, to the current CAN/CGA-

B149 installation code (Canada) or National Fuel Gas

Code ANSI Z223.1.2 (USA)

• To prevent injury, do not allow anyone who is unfamiliar with the stove to operate it.

• To prevent injury, if the pilot or pilot and burners have gone out on their own, open the glass door and wait 5 minutes to air out before attempting to re-light the stove.

• Always keep the area around these appliances clear of combustible material, gasoline and other flammable liquids and vapours.

• These appliances should not be used as a drying rack for clothing or for hanging Christmas stockings/ decorations.

• Due to the paint curing on the stove, a faint odor and slight smoking will likely be noticed when the stove is first used. Open a window until the smoking stops.

Always connect this gas stove to a vent system and vent to the outside of the building envelope. Never vent to another room or inside the building. Make sure the specified vent pipe is used, properly sized and of adequate height to provide sufficient draft. Inspect the venting system annually for blockage and signs of deterioration.

WARNING: Failure to position the parts in accordance with the diagrams in this booklet, or failure to use only parts specifically approved with this appliance, may result in property damage or personal injury.

WARNING: Do not operate with the glass front removed, cracked or broken. Replacement of the glass should be done by a licensed or qualified service person.

• Never use solid fuels such as wood, paper, cardboard, coal, or any flammable liquids, etc., in this appliance.

• Do not use this heater if any part has been under water. Immediately call a qualified service technician to inspect the heater and to replace any part of the control or gas control systems that have been under water.

• Do not abuse the glass by striking it or slamming the door shut.

Table of Contents

Safety Precautions............................................................................................................2

Table of Contents.............................................................................................................3

Codes And Approvals........................................................................................................4

Rating Label Location...........................................................................................4

Specifications...................................................................................................................5

Dimensions..........................................................................................................5

Operating Instructions......................................................................................................6

Pilot Lighting Instructions......................................................................................6

Pilot Light............................................................................................................7

Air Shutter...........................................................................................................7

Blower speed.......................................................................................................7

Burner Lighting....................................................................................................8

Remote controls...................................................................................................8

Normal Sounds During Operation...........................................................................8

Maintenance And Service..................................................................................................9

Routine Maintenance............................................................................................9

Cleaning The Glass...............................................................................................9

Cleaning The Firebox............................................................................................9

Replacing the Glass..............................................................................................9

Cleaning Decorative Surfaces...............................................................................10

Glass Door Removal............................................................................................10

Fuel Conversion..................................................................................................11

Initial Installation............................................................................................................12

Introduction.......................................................................................................12

Vent Heat Sheild Set-Up......................................................................................12

Placement and Framing.......................................................................................13

Corner Installation..............................................................................................14

Raised Fireplaces and Hearths.............................................................................14

Framing Mount Brackets......................................................................................15

Wall Finishes......................................................................................................16

Mantel Clearances..............................................................................................17

Vent Termination Restrictions..............................................................................18

Fireplace Horizontal Vent Kit 50-1235...................................................................19

Other Approved Vent Parts..................................................................................20

Venting..............................................................................................................22

Vent Configurations and Restrictor Settings..........................................................23

Horizontal Termination........................................................................................24

Vertical Termination............................................................................................25

Electrical System For Thermostat.........................................................................28

Installation Of Electrical Wiring For The Optional Fan Kit........................................28

Gas Line Connection and Testing.........................................................................29

Secondary Installation.....................................................................................................30

Optional Fan Kit Installation.................................................................................30

Optional Fan Kit Installation Through Front of Retreat...........................................30

Optional Fan Kit Installation Through Back of Retreat............................................31

Log Set and Ember Installation............................................................................32

Installation of Ceramic Firebox Liner......................................................................33

Installation of The Fascia.....................................................................................34

Trouble Shooting............................................................................................................35

Parts List - Components..................................................................................................36

Parts List - Options.........................................................................................................37

Parts Diagram - Components...........................................................................................38

Parts Diagram - Fascia....................................................................................................39

Warranty........................................................................................................................40

Installation Data Sheet....................................................................................................41

3

Codes And Approvals

DIRECT VENT ONLY: This appliance draws all of its air for combustion from outside the dwelling, through a specially designed vent pipe system.

This appliance has been tested and approved for installations from 0 feet to 4500 feet (1372 m) above sea level.

In the USA: The appliance may be installed at higher altitudes. Please refer to your American Gas

Association guidelines which state: the sea level rated input of Gas Designed Appliances installed at elevations above 2000 (610 m) feet is to be reduced 4% for each 1000 feet (305 m) above sea level.

Refer also to local authorities or codes which have jurisdiction in your area regarding the de-rate guidelines.

In Canada : When the appliance is installed at elevations above 4500 feet (1372 m), the certified high altitude rating shall be reduced at the rate of 4% for each additional 1000 feet (305 m).

• This appliance has been tested by INTERTEK ( Warnock Hersey ) and found to comply with the established VENTED GAS FIREPLACE HEATER standards in CANADA and the USA as follows:

4

VENTED GAS FIREPLACE HEATER (Retreat; NG/LPG)

TESTED TO: ANSI Z21.88a-2003/CSA 2.33a-2003 VENTED GAS FIREPLACE HEATERS

CAN/CGA 2.17-M91 GAS FIRED APPLIANCES FOR HIGH ALTITUDES

CSA P.4.1-02 TESTING METHOD FOR MEASURING ANNUAL FIREPLACE EFFICIENCY

This ENVIRO Retreat Fireplace:

• Has been certified for use with either natural or propane gases. (See rating label.)

• Is not for use with solid fuels.

• Is approved for bedroom or bed sitting room. ( IN CANADA : must be installed with a listed wall thermostat. IN USA : see current ANSI Z223.1 for installation instructions.)

• Must be installed in accordance with local codes. If none exist, use current installation code CAN/CGA B149 in Canada or ANSI Z223.1/NFPA 54 in the

USA.

• Must be properly connected to an approved venting system and not connected to a chimney flue serving a separate solid-fuel burning appliance.

• Can be used with a fan kit (part number 50-1211); if so, 14/2 wire power cable must be wired to the appliance upon installation.

IMPORTANT NOTICE (Regarding first fire up): When the unit is turned on for the first time, it should be turned onto high without the fan on for the first 4 hours. This will cure the paint, logs, gasket material and other products used in the manufacturing process. It is advisable to open a window or door, as the unit will start to smoke and can irritate some people.

After the unit has gone through the first burn, turn the unit off including the pilot, let the unit get cold then remove the glass door and clean it with a good gas fireplace glass cleaner, available at your local ENVIRO dealer.

R ATING L ABEL L OCATION :

The rating label is located under the control panel and is attached to a rectangular metal sheet that is chained to the fireplace.

Specifications

INSTALLATION OPTIONS:

• Parallel to a wall or placed in a corner

• Vertical or horizontal venting

• With a floor hearth or raised up the wall

WARNING:

Operation of this heater when not connected to a properly installed and maintained venting system can result in carbon monoxide (CO) poisoning and possible death.

D IMENSIONS :

12 5 / 16 "

(312mm)

6 5 / 8 " (168mm)

4" (102mm)

8"

(203mm)

45 o

7 3 / 16 "

(183mm)

13 7 / 16 "

(342mm)

11 1 / 2 "

(292mm)

8 1 / 8 "

(206mm)

45 o

41 7 / 16 "

(1052mm)

1 11 / 16 "

(42mm)

40 1 /

4

"

(1022mm)

34 3 /

4

"

(883mm)

8 1 / 2 "

(216mm)

1 5 / 8 "

(41mm)

6 3 / 16 "

(158mm)

12 9 / 16 "

(319mm)

8 11 / 16 "

(220mm)

28 7 / 8 "

(734mm)

43"

(1093mm)

18 3 / 16 "

(462mm)

26 11 /

16

"

(678mm)

21 11 / 16 " (551mm)

23" (584mm)

4 3 / 4 "

(121mm)

Electrical Access

1 5 / 8 "

(41mm)

3 7 /

8

"

(98mm)

5 9 / 16 "

(141mm)

6 3 / 16 " (158mm)

8 1 /

2

"

(215mm)

Gas Line Access

Figure 1. Dimensions of the Fireplace.

41 11 / 16 "

(1059mm)

1 11 / 16 "

(42mm)

5

6

Operating Instructions

For Your Safety, Read Safety Precautions And

Lighting Instructions Before Operating

WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY A FIRE OR EXPLOSION MAY

RESULT, CAUSING PROPERTY DAMAGE, PERSONAL INJURY OF LOSS OF LIFE.

P ILOT L IGHTING I NSTRUCTIONS :

CAUTION:

Hot while operating. Do not touch. Severe burns may result. Keep children, clothing, furniture, gasoline or other flammable vapors away .

CAUTION: Do not operate this fireplace with the glass removed, cracked or broken. Replacement of the panel(s) should be done by a licensed or qualified person! This appliance needs fresh air for safe operation and must be installed with provisions for combustion and ventilation air. See installation and operating instructions manual. Keep burner and control compartment clean.

WARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage, or loss of life. Refer to owner's information manual provided with this appliance. For assistance or additional information consult a qualified installer, service agency or the gas supplier.

Keep burner and control compartment clean. See installation and operating instructions accompanying appliance.

FOR YOUR SAFETY READ BEFORE

WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING

PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.

A) This appliance is equipped with a pilot, which must be lit by hand by following these instructions exactly.

C) Use only your hand to push in or turn the gas control knob;

NEVER use tools. If the knob will not push in or turn by hand, do not try to repair it. Call a qualified service technician.

Force or attempted repair may result in a fire or explosion.

B) BEFORE LIGHTING smell all around the appliance area for gas and next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS:

Do not try to light any appliance. Do not touch any electrical switch: do not use any phone in your building. Immediately call your gas supplier from a neighbors' phone. Follow the gas suppliers instructions. If you cannot reach your gas supplier, call the fire department.

D) Do not use this appliance if any part has been under water.

Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

1. STOP! Read the safety information above on this label.

2. Turn off all electrical power to this appliance.

3. Turn the gas control knob clockwise

LIGHTING INSTRUCTIONS to the off position.

WARNING: this gas valve has a lockout device, which will not allow the pilot burner to be relit until the thermocouple has cooled. If the knob does not pop up when released, stop and immediately call your service technician or gas supplier.

4. Open door. Wait five (5) minutes to clear out any gas. Close door. If you smell gas STOP! Follow “B” in the above safety information. If you do not smell gas go to the next step.

5. Find pilot-located to the right behind the side log. Turn the gas control knob counter-clockwise to “PILOT”. Push the gas control in fully and hold. Keep knob depressed for about 30 seconds after pilot is lit. Release knob.

If pilot goes out, repeat steps 4 through 5.

If the pilot does not stay lit after several tries, turn the gas control knob to “OFF” and call your service technician or gas supplier.

6. Turn the gas control knob counter clockwise to the

“ON” position. Flip the burner switch to “ON” THEN TURN

THE “HI/LOW” knob to the desired setting.

7. Turn on the electrical power to the unit.

1. Flip burner switch to “OFF”

2. Turn the gas control knob clockwise position

TO TURN OFF GAS TO APPLIANCE to the “OFF”

3. Turn off all electrical power to the appliance if service is to be performed.

�������

Figure 2. Lighting Instruction Label

Operating Instructions

P ILOT L IGHT :

1. Turn off the gas to the fireplace. If not recently done, remove the glass and let the unit air out for at least five (5) minutes to clear out any gas. Turn on gas to the heater. Leak test all joints with soapy water. NEVER USE OPEN FLAME FOR LEAK TESTING.

2. Start the pilot by pressing the gas control knob and turning it to PILOT.

While holding the gas control knob in, press the piezo ignitor several times until the pilot light starts. Hold the gas control knob in for 30 seconds.

Check that the pilot has fully engulfed the thermocouple assembly (see

Figure 3).

���������� ������������

3. Start the main burner by turning the gas control knob to ON and then turn the rocker switch to ON. Check that all burner ports have flame.

4. Leak test all gas joints again.

Figure 3. Pilot Flame

A IR S HUTTER :

The air shutter adjustment lever is above the left side of the control valve (see Figure 4).

The air shutter allows the amount of air coming into the fireplace to be adjusted in order to accommodate different altitudes and venting arrangements. Start the pilot and then the burner. Make sure the pilot flame is burning normally and none of the burner ports are plugged. Let the fireplace burn for roughly fifteen minutes and then examine the flames, compare the flames to Figure 53.

The ideal flame will be blue at the base and light orange above. The flames should be of medium height.

If the flames look like this, no venturi adjustment is needed. If the flames are fairly short and mostly blue, the fireplace is getting too much air. Therefore, the air shutter should be closed (moved right)

Open/

More Air

Close/

Less Air slightly until the correct flames are achieved.

Flames that are very orange, with tall, dark, stringy tips, are not getting enough air. Open

(move left) the venturi until the flames clean up.

Air Shutter

If the venturi is opened, or closed all the way, and the correct flames cannot be attained, turn off the gas and contact your dealer.

Warning: Incorrect venturi adjustment may lead to improper combustion, which could be a safety hazard. Contact your dealer if there is any concern about the venturi adjustment.

Figure 4. Air shutter adjustment lever.

B LOWER SPEED :

The blower will come on only when the fireplace is up to temperature (approximately 20 minutes). The speed of the fan can be changed by turning the fan control knob. To turn the blower off, turn the knob

COUNTER CLOCKWISE until it “clicks” off (Figure 5).

It is advisable not to operate the blower below 1 /

3

speed as it puts a strain on the windings of the blower and running the blower at lower speeds could also cause premature fan failure.

7

8

Operating Instructions

For Your Safety, Read Safety Precautions And

Lighting Instructions Before Operating

B URNER L IGHTING :

A) Make sure the pilot is lit.

B) Turn gas control knob COUNTER

CLOCKWISE to ON.

C) Flip the burner switch to ON.

D) Turn HI/LO knob to the desired flame height.

E) Turn on all electrical power to the unit.

NOTE: Check that all burner holes are lit.

Piezo Ignitor

Opening for the Optional

Remote Control

Valve Manifold

Pressure Tap

Gas Line

Pressure Tap

High

���

Low

Blower Speed

Control

������ ��

����������

���

��

TO TURN GAS FIREPLACE OFF: Rating Label

Valve Wiring

Access

HI/LO

Control

Gas

Control

On/Off/Remote

Rocker Switch

Flip switch to OFF to turn off burners only.

Figure 5. Control Panel

If the fireplace is to be turned off for the season, or for servicing, turn the gas shut off valve to OFF. DO

NOT FORCE IT. If the unit is going to be serviced, turn off the electrical power to the unit as well.

NOTE: When the unit is turned on for the first time, it should be turned onto high, with the fan OFF, for the first two to four hours.

This will cure the paint, logs, gasket material, and other products used in the manufacturing process. It is advised that a door or window be opened as the unit will start to smoke, which can irritate some people. After the unit has gone through the first burn, turn the unit OFF, including the pilot, and let the unit get completely cold. Then remove the glass and clean it with a good gas fireplace glass cleaner, available at your local Enviro dealer. See “ M AINTENANCE A ND S ERVICE ; G LASS

D OOR R EMOVAL ” and “ M AINTENANCE A ND S ERVICE ; C LEANING T HE G LASS .”

R EMOTE CONTROLS :

This fireplace can use an optional remote control or an optional cordless wall thermostat. If either of these are to be used to control the fireplace for the majority of the time, leave the ON/OFF switch (on the control panel) in the remote/thermostat position. Consult the instructions included with the remote/wall thermostat for operation guidelines.

N ORMAL S OUNDS D URING O PERATION :

Component

Retreat & Fascia

Burner

Temperature Sensor

Pilot Flame

Blower / Fan

Gas Control Valve

Table 1: Normal Sounds

Sound & Reason

Creaking when heating up or cooling down.

Pop when turned off; this is more common with LP units.

Clinking when it senses to turn the blower on or off.

Quiet whisper while the pilot flame in on.

Air movement that increase and decreases with the speed of the blower.

The blower is pushing the heat from the fireplace into the room.

Dull click when turning on or off, this is the valve opening and closing.

Maintenance And Service

R OUTINE M AINTENANCE :

At least once a year, run through the following procedures to ensure the system is clean and working properly. Check the burner to see if all the ports are clear and clean. Check the pilot to make sure it is not blocked by anything. The pilot flame should be blue with little or no yellow on the tips.

Warning: Clearances must be sufficient to allow access for maintenance and service

Warning: Failure to position the parts in accordance with this manual, or failure to use only parts specifically approved with this appliance may result in property damage, personal injury, or void your warranty.

The venting system must be periodically examined; it is recommended the examination is done by a qualified agency.

C LEANING T HE G LASS :

When the fireplace is off and has cooled , remove the face of the fireplace along with the glass.

See M

AINTENANCE

A

ND

S

ERVICE

- G

LASS

D

OOR

R

EMOVAL

. Check the gasket material on the back of the glass, making sure that it is attached and intact.

During a cold start up, condensation will sometimes form on the glass. This is a normal condition with all gas fireplaces. However, this condensation can allow dust and lint to cling to the glass surface. Initial paint curing of the appliance may leave a slight film behind the glass, a temporary problem. The glass will need cleaning about two weeks after installation. Use a mild glass cleaner and a soft cloth ; abrasive cleaners will damage the glass and plated surfaces. Depending on the amount of use, the glass should require cleaning no more than two or three times a season. In some instances, a white film may form on the glass, caused by gas impurities. The white film can be removed by using ceramic polish. Do not clean the glass when it is hot.

C LEANING T HE F IREBOX :

Remove the logs carefully, as they are very fragile. Gently remove all the coal chunks and rock wool and place on a paper towel. Vacuum the bottom of the firebox thoroughly. Carefully clean any dust off the logs and remove any lint from the burner and pilot. At this time, inspect the burner pan for cracking or severe warping. If a problem is suspected, contact your dealer. Check the logs for deterioration or large amounts of soot; a small amount on the bottom side of the logs is normal. Replace the logs and embers as in the L

OG

S

ET AND

E

MBER

I

NSTALLATION

section. If new/more rock wool is required, contact your nearest

ENVIRO dealer.

R EPLACING THE G LASS :

The glass in the fireplace is a high temperature ceramic. If the glass is damaged in any way, a factory replacement is required (see P ARTS L IST - C OMPONENTS ). Wear gloves when handling damaged glass door assembly to prevent personal injury. When the glass door assembly is being transported, it must be wrapped in newsprint and tape and/or a strong plastic bag. Do not operate your fireplace with the glass front removed, cracked or broken. Removal and replacement of the glass from the door must be done by a licensed or qualified service person. The glass must be purchased from an ENVIRO dealer.

Substitute materials will void the warranty.

9

10

Maintenance And Service

C LEANING D ECORATIVE S URFACES :

Painted and porcelain faces should be wiped with a damp cloth periodically. If a plated face has been purchased, it should be unpacked/unwrapped carefully to avoid getting anything on the surface of the finish, including cleaners, polish and finger prints. It is important to note that fingerprints and other marks can leave a permanent stain on plated finishes. To avoid this, give the face a quick wipe with denatured alcohol on a soft cloth BEFORE lighting the fireplace.

Never clean the face when it is hot. Do not use other cleaners as they may leave a residue, which can become permanently etched into the surface.

G LASS D OOR R EMOVAL :

In order to install the log set, and for regular cleaning, the glass door must be removed. There are two

(2) door latch mechanisms under and two (2) above the glass door shown in Figure 6 & 7. Each latch has two (2) finger grooves, use these to pull the mechanisms straight out. When the latches are unhooked, lift the door up and forward off the unit.

Figure 6. Bottom latches for glass door, disengaged.

To replace the glass door, simply reverse the above procedure.

Warning: Do not touch or attempt to remove the glass if the fireplace is not completely cold.

WARNING: Never operate the fireplace with the glass removed.

Figure 7. Top latches for glass door, engaged.

Maintenance And Service

TO BE INSTALLED BY A QUALIFIED SERVICE AGENCY ONLY

F UEL C ONVERSION :

Warning: This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer’s instructions and all applicable codes and requirements of the authority having jurisdiction. If the information in these instructions is not followed exactly, a fire, explosion or production of carbon monoxide may result causing property damage, personal injury or loss of life. The qualified service agency is responsible for the proper installation of this kit. The installation is not proper or complete until the operation of the converted appliance is checked as specified in the manufacturer’s instructions supplied with the kit.

Please read and follow these instructions. Also, please read the instruction guidelines provided by S.I.T. on how to remove and install the HI/LO regulator.

Step 1. Carefully inspect all parts supplied with this conversion kit.

Step 2. Shut the gas supply off at the shut-off valve. (CAUTION: The gas supply shall be shut off prior to disconnecting the electrical power, before proceeding with the conversion.)

Step 3.

Remove the glass as shown in the M

AINTENANCE AND

S

ERVICE

.

Step 4.

Change the regulator on the front of the gas valve (follow the instructions provided by S.I.T.).

Step 5.

To change the pilot, simply pull the pilot hood straight up to access the pilot injector. Using a 5 / 32 inch Allen key, remove the pilot injector.

Figure 8. Ignitor assembly beside the burner.

Step 6.

Install the new pilot injector supplied with this conversion kit. Simply screw the new injector inside the pilot hood, using the Allen key, and reinstall the hood by placing the hood on the assembly, line up the key way, and snap into place.

Step 7. Remove the main burner orifice with a 1⁄2 inch deep socket.

Step 8.

Install the new orifice supplied. Be sure to put a bead of pipe-thread sealant or approved

Teflon tape on the orifice threads before installing into the brass elbow.

Step 9.

Reinstall the burner tray, log set, embers, and glass. When re-installing the burner, ensure that the burner to pilot hood relationship is as shown on Figure 8.

Step 10.

Open the shut-off valve at the gas line to the unit located in the control panel area.

Step 11.

Use a small brush to apply a warm soapy water solution to all gas connections (use a half dish soap and half warm water). If a gas leak is present, bubbling will occur. Gas leaks can be repaired by using an approved pipe thread sealant or approved Teflon tape. NEVER USE AN

OPEN FLAME WHEN TESTING FOR LEAKS.

Step 12. Re-light the fireplace to ensure proper operation and proper flame appearance.

Step 13. MAKE SURE that the sticker provided by S.I.T. is installed, to signify that the valve has been converted to a different fuel type. Also, make sure that the rating plate has a conversion label to show this unit has been converted to a different fuel type.

A VISUAL CHECK OF THE REGULATOR KNOB IS NECESSARY TO DETERMINE WHETHER OR NOT THE

REGULATOR IS THE CORRECT PART. A 50% TURN DOWN REGULATOR WILL HAVE ONLY ONE CORNER

ON THE KNOB

Conversion Kit should contain the following:

(1) 50% turn down HI/LO regulator with three (3) T-20 Torx screws

(1) Pilot injector

Conversion instructions

Labels to show conversion

(1) Main Orifice

Pilot Orifice

(NG #40 DMS; LP #55 DMS)

(NG 0.62 mm; LP 0.35 mm)

11

Initial Installation

QUALIFIED INSTALLERS ONLY

I NTRODUCTION :

This section of the owner’s manual is for the use of qualified technicians only. Fireplace placement, hearths, facing, mantles, and venting terminations will be covered, as well as the gas and electric systems. There are several installation safety guidelines that must be adhered to. Please carefully read the safety precautions at the front of this manual.

Warning: Clearances must be sufficient to allow access for maintenance and service.

V ENT H EAT S HIELD S ET -U P :

The vent shield must be set-up prior to the Retreat being installed.

1. The heat shield is shipped flat (see Figure 9). The flat shield must be bent up 90° to the top of the unit (see Figure 10).

2. Bend the two (2) side flaps 45° back around the vent (see Figure 11).

Figure 9. Vent Heat Shield Flat.

12

Figure 10. Vent Heat Shield Bent Up.

Figure 11. Vent Heat Shield Sides Bent.

Initial Installation

QUALIFIED INSTALLERS ONLY

P LACEMENT AND F RAMING :

40 1 /

4

"

(1022mm)

A firestop is required through the rear wall.

61" (1.55m) minimum

Ceiling Height

Above the unit

&

84" (2.13m) minimum

Ceiling Height in

Front of the unit

The fireplace can be located along a wall, raised or at floor level, or in a corner. There are specific framing measurements for each situation. The basic opening should have the dimensions shown in Figure 12 and Table 2.

Refer to Figure 1 and Table 3 for the placement of the gas and electrical inlets. When the basic framing is done and the unit is installed the three (3) top pieces of the framing should be installed Figure 13.

Table 2. Framing Dimensions.

Firebox Framing

Depth

Width

Height

135⁄8”

23”

401⁄4”

34.6 cm

58.4 cm

102.2 cm installing these frame pieces

23"

(584mm)

5 5 /

16

"

(135mm)

40 1 /4"

(1022mm)

12 3 /

8

"

(315mm)

45 o

13 5 / 8 "

(346mm)

Figure 12. Dimensions for Framing the Firebox.

Table 3. Inlet Placement Dimensions, refer to Figure 1.

Side Inlet: Gas Electrical

Distance back 6 3 /

16

” 15.8 cm 81⁄2 21.5 cm

Distance up 15⁄8” 4.1 cm 1 11 /

16

” 4.3 cm

Bottom Inlet: Gas Electrical

Distance back 5 9 /

16

” 14.1 cm 8 11 /

16

” 22.0 cm

Distance from side

37⁄8” 9.8 cm 43⁄4” 12.1 cm

34 15 /

16

"

Figure 13. Dimensions for Top

Framing the Firebox.

The fireplace must have a strong and level surface to be placed on. The surface should be made of wood or a non-combustible material, not carpet.

The framing boards may touch the top, side and back standoffs, but no insulation or other material can be placed between the frame and the standoffs.

13

14

Initial Installation

QUALIFIED INSTALLERS ONLY

The gas line, 3⁄8 inch NPT, can be brought to either the right side, the left side, or the bottom of the fireplace. If this set up is inconvenient, the electrical wire and the gas line configuration can be reversed.

The location should be chosen so the fireplace must be at least 36 inches (91.4 cm) from drapes, doors and other combustibles. The framed opening should also be a minimum of 6.5 inches (16.5 cm) from the nearest perpendicular wall (sidewall to the edge of the opening).

The Retreat is designed so it can be installed at floor level without a required hearth

.

C ORNER I NSTALLATION :

8 1 / 4 "

The dimensions for installing a fireplace in the corner of a room are given in Figures 14. Refer to “ I

NITIAL

I

NSTALLATION

- V

ENT

C ONFIGURATIONS AND R ESTRICTOR

S ETTINGS ” for allowable pipe lengths.

Do not interfere with the structural integrity of the walls.

2"x6"

Stud

27 13 / 16 " (706mm)

23" (584mm)

1 / 2 " (13mm)

39 5 / 16 " (998mm)

Figure 14. Dimensions for a corner installation.

R AISED F IREPLACES AND H EARTHS :

Even though the Retreat can be installed at floor level without a hearth, there are a few options with raised fireplaces: raised with a raised hearth (Figure 15), raised with a floor level hearth (Figure 16), or raised with no hearth (Figure 17). If the fireplace is raised, it cannot be placed within 431⁄2 inches (110.5 cm) of the ceiling. When installing a raised fireplace, it is imperative that the support stand is strong enough to hold the weight of the fireplace (up to 200lb [90.7Kg]) and venting.

Initial Installation

QUALIFIED INSTALLERS ONLY minimum to ceiling

Figure 15. Raised Fireplace with Raised Hearth.

Figure 16. Raised Fireplace with Floor Level

Hearth.

F RAMING M OUNT B RACKETS :

Figure 17. Raised Fireplace with No Hearth.

Back Tabs; bent up & screwed into the wood framing

Wood Framing

Drywall

The Retreat can be secured to the framing and the flooring. At either side of the top there are two (2) brackets with holes for screws or nails (Figure 18); the back tabs are to mount to the wood framing and the front ones are to mount to the drywall. At the bottom there are two (2) mounting holes in the unit base below the firebox, which allows for screws or nails to mount to the floor (Figure 19).

Front Tabs; bent up & screwed into the drywall

Figure 18. Top Mounting brackets.

15

Initial Installation

QUALIFIED INSTALLERS ONLY

Bottom

Mounting

Holes

Figure 19. Bottom Mounting Holes.

Shut-off

Valve

W ALL F INISHES :

Both of the Retreat faces will allow for up to a 1” (25 mm) thick finishing wall (example drywall and tile); see Figure 20 & 21. The wall may be finished up to the fireplace standoffs with combustible materials.

This facing style should tuck under the bottom edge at the front bottom of the Retreat for concealment.

When finishing with brick, the brick must frame around the outside of the face (see Figure 22).

See the corresponding fascia instruction sheet for approximate dimensions.

Plywood

Drywall

Figure 20. Drywall Facing Only Around The

Retreat.

Tile

Drywall

Plywood

16

Figure 21. Drywall & Tile Facing Around The

Retreat.

Brick

Plywood

Drywall

Figure 22. Drywall & Brick Facing Around The

Retreat.

M ANTEL C LEARANCES :

Initial Installation

QUALIFIED INSTALLERS ONLY

It is not necessary to install a mantel, but if one is desired it is important to follow the guidelines.

Top of unit to 2x4 header framing: 0” (0 cm)

Top of unit to bottom of 31⁄2” (8.9 cm) mantel: 13” (33.0 cm)

Top of unit to bottom of 10” (25.4 cm) mantel: 141⁄2” (36.8 cm)

Top of unit to bottom of 12” (30.5 cm) mantel: 16” (40.6 cm)

12"

(305mm)

10"

(254mm)

3 1 /

2

"

(89mm)

16"

(406mm)

14 1 /

2

"

(368mm)

13"

(330mm)

2 1 /

2

"

(64mm)

3 /

4

"

(19mm)

Combustible Facing

(up to 1" (25mm) thick)

Combustible Header

1 3 /

16

"

(30mm)

Combustible board

20 3 /

4

"

(521mm)

Top of unit

40 1 /

4

"

(1022mm)

Figure 24. Combustible Shelf Clearance

When combustible materials are directly above a 90 o elbow, the clearance from the top of the elbow is 3” (76mm) for rigid pipe & 4 3/8”

(111mm) for flex pipe. When the elbow is above the unit, the clearance is 8” (203mm) above the elbow.

A shelf may be installed above the unit.

We recommend that no heat sensitive items or components be placed on the shelf (see Figure 24).

Figure 23. Combustible Mantle Clearances.

17

Initial Installation

QUALIFIED INSTALLERS ONLY

V ENT T ERMINATION R ESTRICTIONS :

18

D E

L

B

N

F

H

C

Fixed

Closed

B

Openable

B

Fixed

Closed

B

Openable

Termination Cap

A

J

Air Supply Inlet G Gas Meter

G

M

I

Restriction Zone

(Termination not allowed)

Figure 25. Vent Termination Restrictions, refer to Table 4.

O

K

G

A

Letter

A

B

C

D

G

H

E

F

J

I

K

L

M

N

6 ft (1.83 m)

Table 4: Vent termination clearances, refer to Figure 25.

Canadian Installation

1

12 in (30 cm)

US Installation

2

12 in (30 cm) 9 in (23 cm)

12 in (30 cm)*

24 in (60 cm)*

18 in (45 cm)*

12 in (30 cm)*

3 ft (91 cm) within a height of

15 ft (4.5 m) above the meter/ regulator assembly

3 ft (91 cm)

12 in (30 cm)*

3 ft (91 cm) within a height of

15 ft (4.5 m) above the meter/ regulator assembly*

3 ft (91 cm)*

12 in (30 cm) 9 in (23 cm)

Description

Clearance above grade, verandah, porch, deck, or balcony.

Clearance from window or door that may be opened.

Clearance from permanently closed window (to prevent condensation).

Vertical clearance to ventilated soffit located above the terminal, within a horizontal distance of 2 ft (60 cm) from center line of terminal.

Clearance to unventilated soffit.

Clearance to outside corner.

Clearance to inside corner.

Clearance to each side of center line extended above meter/regulator assembly.

Radial clearance around service regulator vent outlet.

Clearance to non-mechanical air supply inlet to building, or the combustion air inlet to any other appliance.

Clearance to mechanical air supply inlet.

7 ft (2.13 m)t

3 ft (91 cm) above if within 10 ft (3 m) horizontally

7 ft (2.13 m)*t

12 in / 30 cm+

12 in (30 cm)*

12 in (30 cm)

12 in / 30 cm*+

Clearance above paved sidewalk or paved driveway located on public property.

Clearance under verandah, porch, deck, or balcony.

Clearance horizontally to any surface (such as an exterior wall) for vertical terminations.

Clearance above roof line for vertical terminations.

O

1 In accordance with the current CSA B149, Natural Gas and Propane Installation Code.

2 In accordance with the current ANSI Z223.1 NFPA 54, National Fuel Gas Code.

t A vent shall not terminate directly above a side walk or paved driveway that is located between two single family dwellings and it serves both dwellings.

+ Permitted only if verandah, porch, deck, or balcony is fully open on a minimum of two sides beneath the floo r.

NOTE: Venting terminals shall not be recessed into walls or siding.

Initial Installation

QUALIFIED INSTALLERS ONLY

F IREPLACE H ORIZONTAL V ENT K IT 50-1235:

Please read and understand these instructions before installing. Failure to follow these instructions carefully could cause property damage or personal injury.

KIT COMPONENTS:

Qnty Description

1 Horizontal direct vent termination cap

1 Flue collar adapter

1

1

1

Wall thimble

5’ (190 cm) length of Ø4” (10 cm) double walled flex pipe

5’ (190 cm) length of Ø65⁄8” (10 cm) double walled flex pipe

Qnty Description

4 Wire spacers

1 4 oz tube Mill-Pac Sealant

1

12

8

4 oz tube RTV silicone

9 / 16 ” tech screws

11⁄2” wood screws

Please ensure that all components are supplied with this kit. If components are missing or have been damaged, contact your dealer, distributor, or courier company. Do not attempt the installation if components are missing or damaged.

INSTALLATION INSTRUCTIONS:

1. Plan your installation and clearances to combustibles. Decide on a location for the unit that will meet the clearances noted in the venting section, and any or all local code requirements.

2. Set the appliance in the desired location. Determine if any wall studs, electrical wiring, or plumbing pipes are in the way of the venting system as it passes through the exterior wall. The fireplace location should be adjusted if obstructions are found in the wall.

3. Project a line from the center point of the flue outlet upward and outward to the desired flue outlet location on the exterior wall. Using this center point, scribe a 10” (25.4 cm) hole or square on the wall.

Cut the hole from the interior through the exterior wall surfaces.

����

�������

4. Frame the hole as shown in Figure 30.

5. Trim the wall thimble to match the wall thickness as necessary. Install the wall thimble and secure it to the inner wall frame using four (4) 11⁄2” wood screws. If a wall is greater than 8” (203mm) in depth, the clearance above the flex must be 43⁄8” (111mm)

6. Apply a bead of Mill-Pac Black sealant to the new Ø4” (10 cm) by 5” (12.5 cm) provided flue collar adaptor. Press the flue collar into the flue outlet of the fireplace so that the Mill-Pac seals the flue collar to the flue outlet.

7. Stretch both the Ø4” (10 cm) flex vent and the Ø65⁄8” (16.25 cm) flex intake liner to the length needed to ensure the flex can be easily connected to the vent terminal.

8. Slide the Ø65⁄8” (16.25 cm) flex intake liner over the flex vent. Install four (4) wire spacers around the flex pipe. Ensure the wire spacers are positioned at either end of the pipes, and at each end of any elbows in the liners (refer to Figure 26 and 27).

Figure 26: Wire Spacers.

Figure 27: Wire Spacer in Place.

19

20

Initial Installation

QUALIFIED INSTALLERS ONLY

9. Install the flex pipe assembly through the wall thimble, ensure that this portion of pipe slides through the outside wall far enough to connect onto the vent termination cap.

10. Apply a bead of Mill-Pac Black sealant to the top section of the Ø4” (10 cm) by 5” (12.5 cm) flue collar adaptor previously installed into the fireplace flue outlet. Slide the Ø4” (10 cm) flex vent over the flue collar and secure with three (3) sheet metal screws evenly spaced.

Horizontal Vent Termination

11. Place a bead of high temperature silicone on the intake collar of the fireplace, slide the Ø65⁄8” (16.25 cm) flex intake liner over the collar, secure the flex liner with three (3) sheet metal screws evenly spaced.

Wall Thimble

Fire Stop

Exhaust 4" Flex Pipe

Wall Framing

12. On the outside of the exterior wall, apply a bead of Mill-Pac Black sealant to the Ø4” (10 cm) pipe of the vent terminal. Slide the flex liner onto the vent terminal and secure with three (3) sheet metal screws evenly spaced.

Wire Spacers

Combusion Air 6 5/8" Flex Pipe

Flue Pipe Adaptor

Figure 28: Installation of Fireplace Horizontal Vent Kit.

13. Place a bead of high temperature silicone on the intake collar of the vent terminal, slide the Ø65⁄8” (16.25 cm) flex intake liner over the collar, secure the flex liner with three (3) sheet metal screws evenly spaced.

14. Attach the vent terminal to the outside of the house using four (4) wood screws provided.

15. Light the appliance and ensure proper operation.

O THER A PPROVED V ENT P ARTS :

Table 5: Approved Vent Manufacturers

Manufacturer

American Metal Products

Security Chimneys International LTD

Selkirk Metalbestos

Simpson Dura-Vent

Trade Name

AmeriVent Direct

Secure Vent

Direct-Temp

Direct Vent GS

Nominal Sizes

4” - 6 5/8”

4” - 6 5/8”

4” - 6 5/8”

4” - 6 5/8”

The Retreat fireplace has been tested and certified for use with SIMPSON DURAVENT TYPE GS PIPE FOR

GAS STOVES. SECURITY CHIMNEY’S “SECURE VENT DIRECT VENT SYSTEM” and SELKIRK “DIRECT-TEMP

VENT SYSTEM” kits are available for horizontal and vertical venting. When using Simpson Duravent, it is recommended that, before installation, a bead of RTV High Temperature Silicone should be applied to each outer vent joint, and Mil-Pac to each inner joint. When planning an installation, it will be necessary to select the proper length of vent pipe for the particular requirements.

Initial Installation

QUALIFIED INSTALLERS ONLY

WARNING: Do not mix parts from different vent manufacturers’s systems.

EXCEPTION TO WARNING: This product has been evaluated by Intertek for using a Direct Vent GS starting collar in conjunction with Secure Vent, Direct-Temp, and Ameri Vent Direct venting systems. Use of these systems with the Direct Vent GS starting collar is deemed acceptable and does not affect the

Intertek WH listing of the appliance.

Table 6: Vent part numbers (Must state if galvanized or black wanted, PART NUMBERS) .

Direct Vent

GS

908

902

945

990

950

907

906

904

903

942

953

963

988

970

911

943

943S

943F

980

991

984

985

978

971

Direct-

Temp

4DT-6

4DT-9

4DT-12

4DT-24

4DT-36

4DT-48

4DT-EL45

4DT-EL90

4DT-VS

4DT-WT

4DT-SC

4DT-FS

4DT-WS/B

4DT-HKA

4DT-AJ

4DT-AF6

4DT-AF12

4DT-VC

4DT-HVC

4DT-HC

4DT-HHC

4DT-VKC

4DT-HKB

Secure Vent

SV4L6

SV4L12

SV4L24

SV4L36

SV4L48

SV4EBR45

SV4EBR90

SV4VS

SV4RSN

SV4FC

SV4BF

SV4BM

SV0SHK

SV4LA12

SV4FA

SV4FB

SV4F

SV4CGV

SV4CHC

SV0FAK

SV0SHK2

Ameri Vent

Direct

4D7

4D12

4D2

4D3

4D4

4D45B

4D90B

4DWT

4DSC

4DFSP

4DWS

4DHTK1

4D12A

4DF

4DF12

4DVC

4DHC

4DVTK

4DHTK2

Description

6” pipe length

7” pipe length

9” pipe length

12” pipe length

24” pipe length

36” pipe length

48” pipe length

45° elbow, black

90° elbow, black

Vinyl siding standoff/sheild

Wall thimble

Storm collar

Fire stop

Wall strap/support/band

Horizontal termination kit (SD: Basic Kit,

SEL: Kit A, SC: Standard Kit)

11” to 14 5 /

8

” pipe, adjustable

4” to 10” pipe , adjustable

11⁄2” to 12” pipe , adjustable

Flashing, 0/12 to 6/12 roof pitch

Flashing, 7/12 to 12/12 roof pitch

Flashing, 1/12 to 7/12 roof pitch

Flashing, 8/12 to 12/12 roof pitch

Flat flashing

Vertical termination

High wind vertical termination

Horizontal square termination

High wind horizontal termination

Vertical termination kit

Horizontal termination kit

(SD: Kit A, SEL: Kit B, SC: Kit)

21

Initial Installation

QUALIFIED INSTALLERS ONLY

V ENTING :

Wall

Thimble

2" (51mm)

46 1⁄4” (1175mm) to a hard pipe

49 1⁄2” (1257mm) to a flex pipe

8" (203mm)

A 1 inch (25 mm) clearance to combustibles must be maintained around any vertical vent pipe. Around a horizontal vent pipe, the clearance to combustibles should be 2 inches (50 mm) for rigid &

43⁄8 inches (111 mm) for flex above, and 11⁄2 inches (38 mm) on the sides and bottom. When combustible materials are directly above a 90° elbow & above the unit, 8 inches (203 mm) of clearance are necessary; when not above the unit, 3 inches (76 mm) for rigid pipe & 43⁄8 inches (111 mm) for flex pipe. A 10 inches (250 mm) x

10 inches (250 mm) frame (see Figure 30) will assure the proper support and spacing for a vent pipe through the ceiling or as it passes through the wall [up to 8 inches (203mm) for flex pipe].

Installations in Canada require that a wall thimble be used for passing through walls and ceilings, see Figure 33. All sealing and vapour barriers must comply with local building codes.

Joists/Studs

Framing

10”

10”

22

Figure 29. Vent Pipe Clearances.

Figure 30. Vent Framing Through the Wall or Ceiling.

When planning an installation, it is necessary to select the proper length of vent pipe for the particular requirements. The configuration of the venting pipes depends on the locations of walls, ceilings and studs.

However, the pipes cannot be of arbitrary length and arrangement. Because the length of the vertical and horizontal sections dramatically affects the burning efficiency of the fireplace, certain guidelines have been set in the Vent Configurations section.

Venting terminals cannot be recessed into a wall or siding.

Hard

Pipe

Flex

Pipe

Vertical Pipe to the Side

Walls

1”

(25.4 mm)

1”

(25.4 mm)

Table 7. Vent Pipe Minimum Clearances.

Horizontal Pipe to the Sides &

Bottom

11⁄2”

(38.1 mm)

11⁄2”

(38.1 mm)

Above an

Elbow Above the Unit

8”

(203 mm)

8”

(203 mm)

Above an Elbow

Not Above the

Unit

3”

(76.2 mm)

4 3/8”

(111 mm)

Above

Horizontal Vent

Pipe

2”

(51 mm)

4 3/8”

(111 mm)

Wall Frame

8”(203mm) or less

10”x10”

(25x25cm)

10”x10”

(25x25cm)

Initial Installation

QUALIFIED INSTALLERS ONLY

V ENT C ONFIGURATIONS AND R ESTRICTOR S ETTINGS :

Figures 31 shows the range of venting options, it shows possible vent configurations if the unit is top vented, for vertical and horizontal terminations, any layout that remains within the shaded area is acceptable. Having the fewest number of elbows is ideal, as they tend to disrupt air movement. Using

45˚ elbows is preferable to using 90˚ elbows. Also, a shorter vent system will perform better than a longer one.

The vent restrictor controls the amount of air moving through the vent pipe. Longer vertical vent lengths necessitate greater restriction; position 1 is open and position 5 is maximum restriction. Figure 31 shows the vent restrictor position required, relative to the length of vent pipe. The vent

32’ (15.12m)

30’ (14.17m)

25’ (11.81m)

20’ (9.45m)

NOTE: The total length of the vent pipes can not exceed 32 feet (15.12 m). Any combination of rise and run can be used as long as it lays within the shaded area (a total of three (3) 90° elbows or six (6) 45° elbows can be used).

In addition to what is shown, if a 90° elbow is used in the horizontal plane,

3 feet (91.4 cm) must be subtracted from the allowable horizontal run

(for each 45° elbow, 11⁄2 feet must be subtracted from the allowable horizontal run). restrictor is located in the center of the fireplace, above the glass. Figure 32 shows the vent restrictor lever and the holes that indicate the different levels. To avoid injury, it is best to make this adjustment when the fireplace is cool or use welder’s gloves or oven mitts and a screw driver to adjust.

Note: 0,0 in Figure 31 represents a 90˚ bend directly off the outlet of the unit, 46

1⁄4” (1175mm) for hard pipe and 49 1⁄2”

(1257mm) for flex pipe from floor, in all horizontal instances.

15’ (7.09m)

10’ (4.72m)

5’ (2.36m)

5 4 3 2 1

5

Vent

Restriction

Positions

4

3

2

0” (0m)

46 1⁄4” (1175mm) hard pipe

49 1⁄2” (1257mm) flex pipe from the floor

0”

(0m)

1

5’

(2.36m)

10’

(4.72m)

15’

(7.09m)

17’

(8.03)

Figure 31. Possible Vent Configurations for Top Vented; Vertical and Horizontal Terminations.

Figure 32. Possible Vent Restrictor Positions.

23

24

Initial Installation

H ORIZONTAL T ERMINATION :

QUALIFIED INSTALLERS ONLY

NOTES:

1. Horizontal pipes must not be level. For every 12 inches (305 mm) of horizontal travel

(away from the stove), there should be at least 1⁄4 inch (6.4 mm) of vertical travel. Never allow the vent to run downward, as this could cause high temperatures or even present the possibility of a fire.

2. The exterior of the horizontal vent termination must not be blocked or obstructed.

3. If the vent termination is not being attached to wood, the four wood screws provided should be replaced with material appropriate fasteners.

4. For buildings with vinyl siding, a vinyl standoff should be installed between the vent cap and the exterior wall. Attach the vinyl siding standoff to the horizontal termination.

Note that the termination bolts onto the flat portion of the standoff, providing an air space between the wall and the vent termination. The air gap prevents excessive heat from possibly melting the vinyl siding.

Elbow

Wall thimble fire stop

Rigid Coaxial Pipe

Horizontal wall termination

Wall framing

5. Horizontal pipes must be supported every 3 feet (914 mm). Plumber’s all round strap will suffice.

Figure 33. Horizontal Vent Termination

6. When running horizontal pipe, clearances to combustibles must be maintained 11⁄2 inches (38 mm) sides, 11⁄2 inches (38 mm) bottom, and 2 inches (51 mm) top.

Step 1.

Set the fireplace in the desired location. Check to determine if wall studs will be in the way when the venting system is attached. If this is the case, the location of the fireplace may have to be adjusted or the venting may have to be offset.

Step 2. Direct vent pipe sections are designed with special twist-lock connections. Dry fit the desired combination of pipe and elbows to the appliance flue collar to ensure good connection.

Step 3. With the pipe in the correct position and attached to the fireplace, mark the wall for a 10 inches

(25.4 cm) x 10 inches (25.4 cm) square hole (see Figure 30). The center of the hole should match the center line of the horizontal pipe. Cut and frame the hole in the exterior wall where the vent will be terminated. If the wall being penetrated is made of a non-combustible material

(i.e. masonry or concrete) a 7 inches (17.8 cm) hole is acceptable.

Initial Installation

QUALIFIED INSTALLERS ONLY

NOTE: For Simpson Duravent only, place a bead of Mil-Pac or Rutland No 78 Stove and Gasket Cement on the outer edge of the inner exhaust pipe (non-flared end). Push the pipe sections together, then twist about 1⁄4 turn, making sure the two sections are fully locked. Wrap all seams with foil ducting tape.

Step 4.

With the hole now framed, the wall thimble installed, and the pipe extending into the wall, proceed to the outside. Attach the termination to the pipe using RTV and Mil-Pac or Rutland No

78 Stove and Gasket Cement to seal joints. The vent pipe must extend into the vent cap at least

11⁄4 inches (3.2 cm). Secure the connection between the vent cap and the pipe by attaching the two (2) sheet metal straps, which extend from the vent cap assembly to the outer wall of the vent pipe. Bend any remaining portion of the strap back towards the vent cap. Security Secure

Vent uses a twist lock cap.

Step 5.

Position the horizontal vent termination in the center of the 10 inches (25.4 cm) square hole and attach to the exterior wall with the four screws provided. The arrow on the vent termination should be pointing up. Run a bead of non-hardening mastic around the edges of the vent cap, to make a seal with the wall. Ensure the proper clearances to combustibles have been maintained.

V ERTICAL T ERMINATION :

Step 1.

Check the instructions for required clearances (air spaces) to combustibles when passing through ceilings, walls, roofs, enclosures, attic rafters, or other nearby combustible surfaces.

Do not pack air spaces with insulation.

Step 2. Set the gas appliance in the desired location. Drop a plumb bob down from the ceiling to the position of the appliance flue exit, and mark the location where the vent will penetrate the ceiling. Drill a small hole at this point. Next, drop a plumb bob from the roof to the hole previously drilled in the ceiling, mark the spot where the vent will penetrate the roof. Determine if ceiling joists, roof rafters, or other framing will obstruct the venting system. You may wish to relocate the appliance, or to offset, to avoid cutting load bearing members.

Step 3.

To install the Round

Support Box/Wall Thimble in a flat ceiling, cut a 10 inch (25.4 cm) square hole in the ceiling, centered in the hole drilled in Step 2.

Frame the hole as shown in Figure 30.

Elbow Strap

Vertical

Termination

Storm Collar

Flashing

Roofing nails

Step 4.

Assemble the desired lengths of black pipe and elbows necessary to reach from the appliance adapter up through the

Round Support Box.

Insure that all pipe and elbow connections are in their fully twist-locked position.

Figure 34. Vertical Vent Termination

25

26

Initial Installation

QUALIFIED INSTALLERS ONLY

STEP 5. Cut hole in the roof centered on the small hole placed in the roof from Step 2. The hole should be of sufficient size to meet minimum requirements for Clearance to Combustibles, as specified.

Continue to assemble lengths of pipe and elbows necessary to reach from the ceiling support box up through the roof line. Galvanized pipe and elbows may be utilized in the attic, as well as above the roof line. The galvanized finish is desirable above the roof line, due to the higher corrosion resistance.

STEP 6.

Once the pipe sections have been joined, and run up through the hole in the roof, slip an elbow strap over the exposed sections, bend the support straps outwards, and push the elbow strap down to the roof level, as shown in Figure 34. Tighten the clamp around the pipe section. Use a level to make sure the pipe is truly vertical. With roofing nails, secure the support straps to the roof. Seal the nails holes heads with non-hardening mastic. Trim the excess length of the support straps that extend out beyond the edge of the flashing.

STEP 7.

Slip the flashing over the pipe section protruding through the roof. Secure the base of the flashing to the roof with roofing nails. Use a non-hardening sealant between the uphill edge of the flashing and the roof. Insure the roofing material overlaps the top edge of the flashing.

Verify that you have at least the minimum clearance to combustibles at the roof line.

STEP 8.

Continue to add pipe sections until the height of the vent cap meets the minimum code requirements. Refer to Figure 35 and Table 8. Note that for steep roof pitches, the vent height must be increased. In high wind conditions, nearby trees, adjoining roof lines, steep pitched roofs, and other similar factors can result in poor draft, or down drafting. In these cases, increasing the vent height may solve the problem.

STEP 9.

Slip the storm collar over the pipe, and push it down to the top of the roof flashing as shown in Figure 34. Use the non-hardening sealant around the joint between the pipe and the storm collar.

STEP 10.

Twist-lock the vent cap.

Dimension ‘H’ obtained from table below.

Figure 35. Height of Vertical Termination;

Reference Table 8.

H

Table 8. Minimum ‘H’ for Figure 35.

Roof Pitch Minimum Height (H)

Flat to 7/8

Over 7/12 to 8/12

Over 8/12 to 9/12

Over 9/12 to 10/12

Over 10/12 to 11/12

Over 11/12 to 12/12

Over 12/12 to 14/12

Over 14/12 to 16/12

Over 16/12 to 18/12

Over 18/12 to 20/12

Over 20/12 to 21/12

Feet

1

1.5

2

2.5

3.25

4

5

6

7

7.5

8

Meters

0.3

0.46

0.61

0.76

0.99

1.22

1.52

1.83

2.13

2.29

2.44

plumber’s tape connected to wall strap

Wall strap

Initial Installation

QUALIFIED INSTALLERS ONLY

45° elbows (x2)

NOTES:

(1) If an offset is necessary in the attic to avoid obstructions, it is important to support the vent pipe every 3 feet (914 mm), to avoid excessive stress on the elbows, and possible separation. Wall straps are available for this purpose (see Figure

36).

(2) When ever possible, use 45 ° degree elbows instead of 90 ° degree elbows. The 45 ° degree elbow offers less restriction to the flow of flue gases and intake air.

(3) For multi story installations; a ceiling firestop is required at the second floor, and any subsequent floors (see Figure 37). The opening should be framed to 10” (254 mm) x 10” (254 mm) inside dimensions, in the same manner as shown in

Figure 30.

Nails

Ceiling firestop

Figure 36. Use of Wall Straps.

(4) Any occupied areas above the first floor, including closets and storage spaces, which the vertical vent passes through, must be enclosed. The enclosure may be framed and sheet-rocked with standard building materials. However consult the appliance manufactures installation instructions for the minimum allowable clearance between the outside of the vent pipe, and the combustible surfaces of the enclosure. Do not fill any required air spaces with insulation.

Use clearances to as defined by appliance and vent pipe manufacturers.

Ceiling

Second floor

Figure 37. Multi-Story Vent Pipe Installation.

27

28

Initial Installation

QUALIFIED INSTALLERS ONLY

E LECTRICAL S YSTEM F OR T HERMOSTAT :

CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing.

20ft (6.1m) of bell wire is included with this unit. Determine the desired location of the thermostat or wall switch (if used). Connect the bell wire to the valve as shown and run it to the desired location for the thermostat or wall switch and make the connection.

Table 9. Recommended Thermostat

Wire Size.

70 ° F

ON

OF

F

Optional

Remote

Control

Purple

ON/OFF/Remote

Thermostat Switch

Blue Thermocouple

Thermopile

Manifold

Pressure Tap

Inlet

Pressure

Tap

Gas Control

Valve

Wire Size

14 gauge

16 gauge

18 gauge

20 gauge

22 gauge

Grey

Max. Length

100 ft (30.48 m)

60 ft (18.29 m)

40 ft (12.00 m)

25 ft (7.62 m)

18 ft (5.49 m)

70 ° F

UP

DOWN

COOL / HEAT

PRO GRAM

Optional

Wall Switch

Optional

Thermostat

Pilot Adjustment

Screw

Figure 38. Wiring Diagram For Gas Valve.

I NSTALLATION O F E LECTRICAL W IRING F OR T HE O PTIONAL F AN K IT :

The electric 14/2 (with ground) wire power cable must be hard wired to the unit at the lower left (or right or bottom if the gas line is to come in on the left) of the unit if a fan is currently installed, or if you plan to install the Optional Fan Kit (50-1211) in the future.

See Figure 1 for possible electrical wire access locations.

Refer to local electrical bylaw codes for proper installation. In the absence of local codes, with the current CSA C22.1 Canadian

Electrical Code Part 1, Safety Standards For Electrical Installations, or The Current National Electrical Code ANSI / NFPA 70 in the

US.

Use a strain relief or cable clamp to attach the wiring to the unit.

Strain Relief /

Cable Clamp

Wiring

Harness

Black

White

Retreat

Green

(Ground)

House

Wiring

WARNING: Ensure that the power is turned of to the lead from the source BEFORE conducting any wiring.

Figure 39. Install Electrical 14/2 with ground Wire Power Cable Into Retreat.

Initial Installation

G AS L INE C ONNECTION AND T ESTING :

WARNING: Only persons licensed to work with gas piping may make the necessary gas connections to this appliance.

GAS LINE CONNECTION

• This fireplace is equipped with a certified flexible pipe located on the right side of the unit. This flexline is connected to a shut-off ball valve, which terminates in a 3⁄8” female NPT fitting. The ball valve can be located on the right or left side of the unit, or where the gas supply can enter through the floor of the unit (see Figure 10). Consult your local authorities codes or the CAN/CGA B 149 (1 or

2) installation code in Canada, or in the USA gas installations follow either local codes or the current edition of the National Fuel Gas Code ANSI Z223.1.

• The efficiency rating of this appliance is a product thermal efficiency rating determined under continuous operating conditions and was determined independently of any installed system.

The appliance and its shutoff valves must be disconnected from the gas supply piping system during any pressure testing where the pressure exceeds 1⁄2 PSIG (3.45 KPa) or damage will occur to the valve.

��������

�������� ���

OUT IN

�����

�������� ���

The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1⁄2 psig (3.45 KPa).

Always check for gas leaks with a soap and water solution after completing the required pressure test.

TO TEST VALVE PRESSURES

T O L I

P

I

H LO

OF F

P

O N

����� ����������

�����

������

����

��� �������

����

Figure 40. Fully Labeled Gas Valve.

The pressure taps are located on the top right of the valve shown in Figure 40.

• Turn set screw 1 turn counter clockwise to loosen,

• Place 5 /

16

” (8 mm) I.D. hose over pressure tap system.

• Check pressures using a manometer.

• When finished, release pressure, remove hose & tighten set screw.

Table 10: Pressure and BTU Information.

Main Orifice

Manifold Pressure

Min. Manifold Pressure

Natural Gas

#40 DMS

3.8” W.C. (0.95 KPa)

1.2” W.C. (0.28 KPa)

Propane

#55 DMS

11.0” W.C. (2.74 KPa)

2.7” W.C. (0.67 KPa)

Max Supply Pressure

Min. Supply Pressure

7.0” W.C. (1.74 KPa)

5.0” W.C. (1.25 KPa)

13.0” W.C. (3.28 KPa)

12.0” W.C. (2.98 KPa)

Max BTU/hr Input 29,280 BTU/hr (8.58 KW) 20,590 BTU/hr (6.03 KW)

Min. BTU/hr Input 16,000 BTU/hr (4.69 KW) 10,300 BTU/hr (3.02 KW)

NEVER USE AN OPEN FLAME FOR LEAK TESTING.

29

30

Secondary Installation

QUALIFIED INSTALLERS ONLY

O PTIONAL F AN K IT I NSTALLATION :

If the Retreat is installed, the burner and valve assemblies may need to be removed. If the Retreat is not installed the fan can be installed under the firebox, or through an access hole at the lower rear of the unit.

Fan Control

The optional fan is thermostatically controlled and it will not operate if the appliance is cold. A few minutes after the appliance is lit and the variable speed

Black Black White

120 o F (49

Sensor o C)

Temperature

White control is set at a desired setting, the fan will automatically turn on. The fan will automatically turn off a few minutes after the appliance is shut off.

Long

Black

Short

Black

Black

Electrical

Power Cord

Green

The fireplace must be electrically connected and grounded in accordance with local codes or, in the absence of local codes, with the current CSA C22.1 Canadian

Electrical Code Part 1, Safety Standards

For Electrical Installations, or The National

Electrical Code ANSI / NFPA 70 in the US.

Figure 41. Wiring Diagram For Fan Control.

CAUTION: When servicing controls, label all wires prior to disconnection. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing.

WARNING: The electrical grounding instructions must be followed. The fan should be properly grounded.

Kit Contents:

This kit includes a fan assembly, a wiring harness, a temperature sensor, fan control dial, two (2) grommets, and two (2) 8-32 x 3⁄4” bolts.

Please ensure that your fan kit has not been damaged. If so, contact your dealer, distributor, or courier company before starting this installation.

O PTIONAL F AN K IT I NSTALLATION T HROUGH F RONT OF R ETREAT :

1. Ensure the appliance is turned off, is cool, and the unit power is turned off.

2. Remove the fascia, glass door and, two (2) screws holding the control panel in place. Disconnect the sparker and rocker switch wires, and remove the panel.

3. Install the two (2) grommets by placing an 8-32 x 3⁄4” bolt through each grommet then screwing the bolt to the back cover using a 1⁄4” socket (see Figure 42)

4. Ensure the wiring harness is attached to the fan then hook the two (2) slots on the fan box over the grommets installed in the last step.

Figure 42. Grommets for Hanging Fan.

Valve removed for clarity.

Secondary Installation

5. Slide the fan temp sensor in place under the holding tabs above the SIT valve (see Figure 43).

6. Remove knob and nut from the fan controller. Place the knob stud through the fan hole in the control panel, the controller tab should align with the control panel hole (see Figure 44). Tighten the nut on the front side to keep the fan controller in place (see Figure 45), then install the knob onto the stud.

7. Use marrettes or approved connectors to connect the fan harness wires to the house wiring.

8. Re-install the control panel wiring and control panel.

Figure 43: Installing Temperature

Sensor.

Figure 44. Install Fan Controller.

O PTIONAL F AN K IT I NSTALLATION T HROUGH B ACK OF R ETREAT :

Figure 45. Install Fan

Controller Nut.

1. Use a flat head screwdriver or a 1⁄4” socket to remove the six (6) screws securing the back cover (see

Figure 46).

2. Remove the two

(2) bottom screws securing the standoff (see Figure 47) and swing it out of the way.

3. Install the two (2) grommets; place a 8-32 x 3⁄4” bolt through

Figure 46: Removing Back Plate From Retreat.

grommet, screw the bolt to the back cover using a 1⁄4” socket. each then

4. Ensure the wiring harness is attached to the fan then hook the two (2) slots on the fan box over the grommets installed in the last step.

5. Slide the fan and wiring harness assembly into the hole in the back of the Retreat, motor side first (see

Figure 48).

Figure 48: Installing Fan Through the Back.

Figure 47: Move Back Stand-

Off.

6. Re-install the back cover and the stand-off screws.

7. Remove the two (2) screws holding the control panel in place. Disconnect the sparker and rocker switch wires, and remove the panel.

8. Slide the fan temp sensor in place under the holding tabs above the SIT valve (see Figure 43).

31

Secondary Installation

9. Remove knob and nut from the fan controller. Place the knob stud through the fan hole in the control panel, the controller tab should align with the control panel hole (see Figure 44). Tighten the nut on the front side to keep the fan controller in place (see Figure 45), then install the knob onto the stud.

10. Use marrettes or approved connectors to connect the fan wiring harness wires to the house wiring when the Retreat is installed.

11. Re-install the control panel wiring and the control panel.

L OG S ET AND E MBER I NSTALLATION :

NOTE: The charcoal pieces and logs are fragile and should be handled gently.

The placement of the charcoal pieces, embers, and logs are not arbitrary. If they are positioned incorrectly, the flames can be “pinched” and will not burn correctly. The burner comes with six (6) locator pins

(pointed out in Figure 49) which make alignment easier. The locator pins are long enough to go through the charcoal and be used to locate the logs. Carefully set the three (3) charcoal pieces in place.

After the charcoal pieces are in, spread the rockwool embers apart, and place them (see

Figure 49) onto the burner in a sparse but even manner to create a realistic look.

WARNING: DO NOT pack this ember material as this could create an unsafe condition. The ember material should be lightly placed so it doesn’t densely block any of the burner ports.

DO NOT place any of the embers against the pilot assembly.

Caution: Use only the type of ember material supplied with this fireplace. Due to the irregular size of the ember material, there will be more than required. Use of other foreign materials on the burners may create dangerous conditions.

Figure 49. Charcoal Pieces & Ember Installation.

Each log sits on two (2) locator pins and should lean against the liner walls

(see Figures 50

& 51).

32

Figure 50. Left & Right Logs Installation.

Figure 51. Centre Log Installation.

Secondary Installation

Figure 52 shows The Retreat burning with a good flame.

NOTE: While the glass is still removed, it is recommended that the gas line be purged by lighting the pilot.

When lighting the fireplace for the first time since the log set and embers have been installed/replaced, watch for ignition at ALL the burner ports. If a long delay is noticed, turn the appliance off and wait for it to cool down. Then remove the glass and rearrange the ember material, ensuring none of the burner ports are densely blocked.

Maintenance: Once a year, the charcoal pieces and logs should be removed and checked for deterioration or large amounts of soot. A small amount on the bottom side of the logs is normal. Remove and replace the logs in the same manner described above.

If new/more rock wool embers are required, contact your nearest ENVIRO dealer.

Figure 52. Retreat complete log set-up with embers burning.

Never operate the fireplace with the glass door removed.

I NSTALLATION OF C ERAMIC F IREBOX L INER :

Turn off the gas control knob and allow the unit to cool.

NOTE: The ceramic liner is fragile and should be handled gently. Please ensure that it has not been damaged.

To install the liner:

1. Remove the glass door by following the instruction in the “ S ECONDARY I NSTALLATION

- G LASS D OOR R EMOVAL ” section and remove logs if necessary.

2. A ceramic liner support must be in place around burner (shown with a white outline in

Figure 53).

Figure 53. Ceramic Liner Support.

33

Secondary Installation

Figure 54. Slid In the Ceramic Liner.

3. Tilt the top of the liner slightly forward and slide one side of the liner into the firebox (see Figure 54 & 55).

Ensure that the liner goes behind the pilot assembly as it is rotated into the firebox. It will be a snug fit. The bottom of the liner must rest on ceramic liner support installed in step 2.

Figure 55. Ceramic Line Put in Place.

4. Once the liner is in the firebox adjust it so it is flush with the front of the firebox, and so that there is some clearance behind the pilot.

I NSTALLATION OF T HE F ASCIA :

1. Ensure the lip with the tabs on the fascia is resting on top of the one on the Retreat (see Figure 56).

2. Slide the two (2) mounting slots at the bottom of the fascia onto the studs on the Retreat (see Figure 56 &

57).

3. Tighten a wingnut on the stud to secure the Chalet to the fascia.

Wingnut

Stud

Fascia

Note: To remove fascia reverse the above steps.

Control

Panel

34

Figure 56: Installing Chalet onto The Retreat.

Figure 57: Fastening Bottom of Chalet.

Trouble Shooting

Problem

Spark will not light the pilot after repeatedly pressing the spark ignitor

Pilot will not remain lit

Burners will not remain lit

Flame lifting

Glass fogs up

Blue Flames

Flames are burning

“dirty” or sooting

Remote control doesn’t work

Possible Cause Solution

Defective piezo ignitor

Broken spark electrode

Misaligned spark electrode • If spark is not arcing from electrode to pilot, loosen the screws on the pilot base adjust and tighten.

Problem with thermocouple circuit

• Check for proper connection of the thermocouple to the rear of the valve. If loose, fully tighten.

• Check pilot for full flame impingement around thermocouple. If flame is too small, check gas pressure, adjust pilot rate screw, check pilot head for damage.

• Check thermocouple voltage at valve. It must be greater than 5 mV. If low, replace thermocouple.

Air in gas line (pilot dies while knob is depressed)

• Check connections to ignitor.

• If ignitor connections are good but no spark, replace ignitor.

• Check for broken ceramic insulation, replace electrode if broken.

Problem with thermopile circuit

• Bleed line.

• Check gas line pressure.

• Contact dealer.

• Check gas line pressure .

• Check for flame impingement on thermopile. If low, see “Pilot will not remain lit”.

• Check thermopile for minimum of 300 mV when burner is switched on.

• Check wiring to thermostat for breaks.

Leak in vent pipe

Improper vent configuration

• Check for leaks in vent connections.

• Check vent configuration with manual.

Terminal may be recirculating flue gases

• Check to see if terminal is on correctly.

• May need to install high wind termination cap.

• Contact dealer.

Normal Condition: after the appliance warms up the glass will clear.

**Due to additives in gas, glass may get hazy during operation** Clean as needed.

Normal during start up: flames will yellow as the fireplace heats up.

Flame impingement • Check log positioning.

• Increase primary air by opening the venturi shutter and/or by opening the vent restrictor.

See also “Burners will not remain lit.”

Problem with the remote • One or more of the batteries are dead. See remote control instructions.

Problem with fireplace • The on/off switch is turned to OFF.

• The gas control valve is turned to PILOT or OFF.

• The pilot has gone out.

35

36

Parts List - Components

10

10

15

16

17

18

11

12

13

14

18

19

20

6

7

4

5

7

8

3

3

3

3

Reference

Number

1

2

2

3

3

3

3

9

Part Description

120°F Ceramic Fan Temperature Sensor

S.I.T. Nova Valve NG (50% turn down)

S.I.T. Nova Valve LP (50% turn down)

Thermocouple

Spark Electrode with Ignitor Cable

Thermopile

Pilot Orifice NG Threaded

Pilot Orifice LP Threaded

Pilot Gasket

SIT Pilot 1⁄8” Tube with End Furrels (1 piece)

Three Flame Pilot Hood

S.I.T. Piezo Ignitor

Burner Switch

Fan Controller - 115V

Convection Blower - 115V

Convection Blower Kit- 115V

Enviro Logo Gel Decal

Blank Orifice #73

On/Off Remote Control Kit

Programmable Wall Mounted Remote Control

Dual Bulb Door Gasket - 10 feet (3.05m)

Door, Glass, & Gasket

Wall Switch Kit

Retreat Owner’s Manual

Manual Shut-Off Valve

Door Latch Spring, Bracket, & Screws (set of 2)

Pilot Shield

Valve Assembly C/W Pilot & Mount

Bell Wire - 20 feet (6.1m)

Log & Coal Set

Conversion Kit from NG to LP

Conversion Kit from LP to NG

Pan Burner

Control Panel

Part Number

EC-001

EC-006

EC-007

EC-009

EC-011

EC-012

EC-019

EC-020

EC-021

30-043

50-925

EC-023

EC-026

EC-039

EG22-001

50-1211

50-322

50-343

50-559

50-583

50-634

50-1338

50-920

50-1269

50-1284

50-1285

50-1287

50-1349

50-1291

50-1295

50-1336

50-1337

50-1339

50-1340

Parts List - Options

24

24

25

25

25

25

23

23

23

22

22

23

Reference

Number

21

21

21

Part Description

Firebox Liner - Bankers Brown Brick

Firebox Liner - Arizona Stucco

Firebox Liner - Red Brick

Fireplace Horizontal Vent Kit - 5 Feet (1.52 m)

Fireplace Horizontal Vent Kit - 10 Feet (3.05 m)

Chalet Face - Inset & Bottom Door - Black Enameled

Chalet Face - Inset & Bottom Door - Bronze Enameled

Chalet Inset - Brushed Nickel

Chalet Inset - Brushed Gold

Chalet Inset - Bronze Enameled

Chalet Inset - Black Enameled

Cape Cod Face & Bottom Door - Black Enameled

Cape Cod Face & Bottom Door - Bronze Enameled

Cape Cod Inset - Black Enameled

Cape Cod Inset - Bronze Enameled

Cape Cod Inset - Brushed Nickel

Cape Cod Inset - Brushed Gold

Part Number

50-1227

50-1228

50-1229

50-1235

50-1293

50-1226

50-1315

50-1309

50-1310

50-1324

50-1325

50-1231

50-1316

50-1326

50-1327

50-1334

50-1335

37

38

Parts Diagram - Components

Parts Diagram - Fascia

25

23

22

24

The Retreat - Fascia

July 2005

39

Warranty

Sherwood Industries Ltd. offers a Limited Lifetime Warranty on this gas product. This Limited Lifetime

Warranty covers the appliance for a period of seven years from the date of installation. This warranty applies only to the original owner in the original location.

Covered under the lifetime warranty are the chassis and the heat exchanger. These steel components are covered against manufacturer’s defects for seven years and the labour for the first year. The following exclusions apply: over-firing due to incorrect setup or tampering, damage caused by incorrect installation, usage or abuse. The unit must be properly installed by a qualified technician or installer, and must meet all local and national gas and building code requirements.

Under the Limited Lifetime Warranty, the following components are also covered: log set, burners and glass. The following exclusions apply:

Plated Finish: Damage caused by scratching, marring, chemicals, fingerprints, abrasive cleaners or discoloration with age. Items with Antique Copper that have had a green discoloration of the finish.

If discoloration occurs, please follow the cleaning instructions as outlined in the “Maintenance And

Service” section.

Glass: Damage caused by the use of harsh or abrasive cleaners, striking the glass, surface contaminants

Log Set & Ceramic Liner: Damage caused by incorrect handling or misuse

Burners: Damage caused by improper or continuous operation under incorrect conditions

Sherwood Industries Ltd. offers a two-year warranty against manufacturing defects on all the electrical components and gas components, paint is also covered against flaking. This offer includes parts and labour for one year, and parts only thereafter.

Your dealer shall make all claims under this warranty in writing. When filing a warranty claim please complete the following information on an official warranty claim form:

TO THE DEALER:

Name, address and telephone number of purchaser and date of purchase, date of installation, name of installer and dealer, nature of complaint, defects or malfunction, description and part number of any parts replaced.

TO THE DISTRIBUTOR:

Sign and verify that work and information are correct.

40

This warranty covers defects in materials and workmanship only if the product has been installed according to the manual’s instructions. If the product is damaged or broken as a result of misuse or mishandling, the warranty does not apply. The warranty does not cover removal and reinstallation costs.

Sherwood Industries Ltd. reserves the right to repair or replace the defective product. The shipping costs are to be paid by the consumer. All warranties by the manufacturer are set forth and no claim shall be made against the manufacturer on any oral warranty or representation.

Sherwood Industries Ltd. and its’ employees or representatives will not assume any damages, either directly or indirectly, caused by improper usage, operation installation, servicing or maintenance of this appliance.

Sherwood Industries Ltd. reserves the right to make changes without notice. Please complete and mail the warranty registration card and have the installer fill in the installation data sheet in the back of the manual for warranty and future reference.

Installation Data Sheet

The following information must be recorded by the installer for warranty purposes and future reference.

NAME OF OWNER: NAME OF DEALER:

_________________________________________

ADDRESS:

_________________________________________

_________________________________________

_________________________________________

PHONE:___________________________________

_________________________________________

ADDRESS:

_________________________________________

_________________________________________

_________________________________________

PHONE:___________________________________

MODEL:___________________________________

SERIAL NUMBER:___________________________

DATE OF PURCHASE: _____________ (dd/mm/yyyy)

DATE OF INSTALLATION:___________ (dd/mm/yyyy)

NATURAL GAS (NAT) � PROPANE(LPG)

INLET GAS PRESSURE:_________in WC

MAIN BURNER ORIFICE:__________# DMS

PILOT ORIFICE #_________OR________in diam.

INSTALLER’S SIGNATURE:

_________________________________________

NAME OF INSTALLER:

_________________________________________

ADDRESS:

_________________________________________

_________________________________________

_________________________________________

PHONE:___________________________________

MANUFACTURED BY:

SHERWOOD INDUSTRIES LTD.

6782 OLDFIELD RD. SAANICHTON, BC, CANADA V8M 2A3 www.envirofire.biz

July 12, 2005

C-10807

41